createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709370041244
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3800.00
emd228000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-03-2024 16:00:00
tenderQueryClose06-03-2024 16:00:00
technicalBidOpen14-03-2024 16:01:00
publishedDate02-03-2024 18:07:01
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate11-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPraveen B A
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9448653156
tenderSupplierListNone
tenderSchedule
createdTs1709370041274
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT359
titleProviding Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya
descriptionProviding Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya
categoryWORKS
categoryTextWorks
ecv15161366.79
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount17000000.0
groupOverheadTotalNone
fileNumberHFW/AEE/MDY/TCLTLineMIMS
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17093700410000NoneNoneBuildingsProviding Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya (Civil Works)626181.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
288429794345Noneitem no:1.3 PWD SR 2023-24Earth work in surface excavation by manual means for lowering & levellingthe ground by chiselling and wedging in Hard rock for all works other thanfoundation & depth not exceeding 100 mm as per drawing and technicalspecifications, including setting out, barricading, caution lights, dressing ofexcavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m includingcost of labour, tools, usage & other appurtenances required to complete thework.Cum215.13215.1360.0FalseNoneNoneFalseNoneFalse12907.80
288429894345Noneitem no:1.4.1 PWD SR 2023-24Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and suchsimillar works in all kinds of soils, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights, removalof stumps and other deleterious matter, excavated surface leveled and sidesneatly dressed disposing off the excavated stuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost oflabour, tools & other appurtenaces required to complete the work.Cum294.13294.1310.0FalseNoneNoneFalseNoneFalse2941.30
288429994345Noneitem no: 2.1.2 PWD SR 2023-24Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum6884.036884.032.5FalseNoneNoneFalseNoneFalse17210.0750
288430094345Noneitem no: 2.1.6 PWD SR 2023-24Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed, laid inlayers not exceeding 150 mm thickness, well compacted using plate vibrators,including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete thework as per technical specifications.Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregatesCum7587.747587.747.5FalseNoneNoneFalseNoneFalse56908.050
288430194345Noneitem no: 11.62 PWD SR 2023-24Supplying and fixing RCC precast fencing pole of size 0.15mx0.15mx2.0m casted in M 20 with 20mm down size aggregates making holes for drawingbarbed wire at 30 cm c/c using 8 mm dia vertical 4 TMT steel rods and6 mm dia stirups at 15 cm c/c fixed 1.5 m above Ground level using steelmoulding , curing , transportation to work spot including excavation in alltypes of soil, fixing in plain cement concrete M15 using 20 mm downsizeaggregate including aligning to plumb and line providing including costof all materials, labour,usage charges of machinery complete.Each1318.711318.7182.0FalseNoneNoneFalseNoneFalse108134.220
288430294345Noneitem no: 11.60 PWD SR 2023-24Providing and fixing G.I. chain link fabric fencing of required width in meshsize 25x25 mm made of G.I. wire of dia 3 mm including strengthening with2 mm dia wire or nuts, bolts and washers as required complete as per thedirection of Engineer-in-charge.Sqm1085.351085.35144.0FalseNoneNoneFalseNoneFalse156290.40
288430394345Noneitem no: 4.1ii PWD SR 2023-24Construction of Granular Sub-Base of required grading as pe design mixing in a mechanical mix plant at OMC, carriageof mixed Material to work site, spreading in uniform layerswith motor grader on prepared surface and compacting withvibratory power roller to achieve the desired density, completeas per clause 401-For Grading -II MaterialCum3111.423111.4260.0FalseNoneNoneFalseNoneFalse186685.20
288430494345Noneitem no: 11.16.2 PWD SR 2023-24Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usagecharges of machinery complete as per specifications and as per directionsof the Engineer-in-Charge.Kgs178.66178.66132.3FalseNoneNoneFalseNoneFalse23636.7180
288430594345Noneitem no: 8.40 PWD SR 2023-24Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and as perdirections of Engineer-in-charge.Sqm139.77139.777.6FalseNoneNoneFalseNoneFalse1062.2520
288430694345Noneitem no:15.21 Ele SR 2023-24Supply and installation of 9Kg Powder Based stored presure type melting point at 1200 degree C, Applicable on Class D metal fires in heavy metals, alkali metals and alloys Pressure Guage, Gross Weight 14.9Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter 175 MM, Discharge Time less than 18 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum4meters, Canconstruction: Deepdrawn& Co., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete CE Approved.Each13977.113977.14.0FalseNoneNoneFalseNoneFalse55908.40
288430794345Noneitem no:15.111 PWD SR 2023-24Supplying of four bucket stand alongwith buckets. CompleteEach2248.492248.492.0FalseNoneNoneFalseNoneFalse4496.980
17093700410000NoneNoneBuildingsProviding Additional 1000 KVA TC, LT Control Panel Board, Construction of HT Yard & Control Panel Room and allied works to MIMS Teaching Hospital at Mandya (Electrical Works)14535185.39
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
288430894346NoneCESC SR III aPre - Stressed Tubular Spun Pole 11 Mtr Long - 500 Kg WL with Labour ChargesNo23820.6623820.662.0FalseNoneNoneFalseNoneFalse47641.320
288430994346NoneCESC SR 2 IX a11 kV, Horizontal Cross Arm with HT Single Top supports, clamps, bolts, nuts & washers - MS For RCC Pole with Labour ChargesNo932.2932.24.0FalseNoneNoneFalseNoneFalse3728.80
288431094346NoneCESC SR 3 XIX f45 KN Disc Insulator PorcelainSet554.6554.612.0FalseNoneNoneFalseNoneFalse6655.20
288431194346NoneCESC SR 3 XIX e11 kV, 5 KN Composite/Polymeric Pin Insulator (24 mm Dia FRP Rod)No260.78260.786.0FalseNoneNoneFalseNoneFalse1564.680
288431294346NoneCESC SR 3 XX bACSR conductor as per IS : 398 (Part - 2/1996)are the latest revision Rabbit ACSR (6/3.35 mm Al+1/3.35 mm St), Std Wt: 214 Kg/KMKm76480.5276480.520.1FalseNoneNoneFalseNoneFalse7648.0520
288431394346NoneCESC SR XXXIIDOLO Cut Out with Labour ChargesNo1427.81427.81.0FalseNoneNoneFalseNoneFalse1427.80
288431494346NoneCESC SR 5 151 17.01LT Protection Kit (Dwg No. BESCOM/GM/QS&S/10 Dtd 24.11.2018 with Labour chargesNo2566.52566.51.0FalseNoneNoneFalseNoneFalse2566.50
288431594346NoneCESC SR 17 444 55.01Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtrm594.72594.7230.0FalseNoneNoneFalseNoneFalse17841.60
288431694346NoneCESC 5 131 13.10Distribution Transformer - 3 Phase 11kV/433V - Amorphous Core with Oil as per IS-1180 (Part-1): 2014 (CESC SR 5/130/ 13.08) B. CABLE ENTRY TYPE. 500 kVA, Aluminium Wdg, Star 2 (5 Star)Each1114274.01114274.02.0FalseNoneNoneFalseNoneFalse2228548.00
288431794346NoneCESC 2 54 3.02Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing Above 250 kVAPer Structure5744.245744.242.0FalseNoneNoneFalseNoneFalse11488.480
288431894346None20 509 61.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018)Unit288840.4288840.41.0FalseNoneNoneFalseNoneFalse288840.40
288431994346None4 P-97 I-8.01Erection of HT metering Cubicle on PlatformNo2036.682036.681.0FalseNoneNoneFalseNoneFalse2036.680
288432094346NoneP-283 I-38.01Conventional RMU (VCB Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC- 62271/IS-3427 3 Way RMU, 2OD + 1VL (One Incomer + One Breakers + One Outgoing)Unit1673825.281673825.281.0FalseNoneNoneFalseNoneFalse1673825.280
288432194346NoneCESC SR 10 P-272 I-36.0511 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975 ( 240 Sqmm, (55 GI Wires - 3.15 mm Dia)Km2441776.362441776.360.2FalseNoneNoneFalseNoneFalse488355.2720
288432294346NoneCESC SR 9 P-226 I-31.02Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 3x185 to 240 SqmmKm56404.056404.00.2FalseNoneNoneFalseNoneFalse11280.80
288432394346NoneBESCOM P.No 8 P-202 I-29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed In Hard SoilCum459.02459.021275.0FalseNoneNoneFalseNoneFalse585250.50
288432494346NoneCESC SR 15 P-363 I-45.08Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x240 SqmmSet6120.666120.662.0FalseNoneNoneFalseNoneFalse12241.320
288432594346NoneCESC SR 15 P-360 I-45.04Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x240 SqmmSet5398.55398.516.0FalseNoneNoneFalseNoneFalse86376.00
288432694346NoneCESC SR 11 P-306 I-35.05Fixing of Termination KitNo411.82411.8218.0FalseNoneNoneFalseNoneFalse7412.760
288432794346NoneS.RHeavy Duty Copper Terminal Long Barrel. 240 Sqmm Copper Terminal, Apprx Wt: 218 GmNo434.24434.2448.0FalseNoneNoneFalseNoneFalse20843.520
288432894346NoneS.RConstruction of platform with size stone, cement concert for erection of 500 kVA Transformer/Metering cubicle/Heavy Equipment.Construction of platform (1.5x1.5x1.2) Mtr in size stone, for erection of transformers/Heavy equipment including all materials, labour. Excavation of (1.5x1.5x1) Mtr pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 10 cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9 Mtr below ground level and 1.2 Mtr above ground level neatly hammer dressed in cement morter 1:6. Providing and Laying cement concrete slab 1.5x1.5x0.10 Mtr with cement concrete of 1:2:4 mix forming & cutting complete, providing pointing to stone masonary in cement morter 1:3 after racking joint & nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely.Per Structure35825.9835825.983.0FalseNoneNoneFalseNoneFalse107477.940
288432994346None17 P-439 I-54.01GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo908.6908.635.0FalseNoneNoneFalseNoneFalse31801.00
288433094346None17 P-440 I-54.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo778.8778.835.0FalseNoneNoneFalseNoneFalse27258.00
288433194346None17 P-441 I-54.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag357.54357.5435.0FalseNoneNoneFalseNoneFalse12513.90
288433294346None17 P-442 I-54.04Rod type of earthing using 40 mm Dia, 3 Mtr long MS rod as ground rod, in earth pit of 300 mm width and 3300 mm depth and using 50x6 mm flat welded to ground rod as terminal & connected to equipment ground terminal using PVC Al wire as specifiedNo2658.542658.5435.0FalseNoneNoneFalseNoneFalse93048.90
288433394346None17 P-443 I-54.05Bentonite clay slurry for earthing in 50 Kg BagNo423.62423.6235.0FalseNoneNoneFalseNoneFalse14826.70
288433494346NoneP-II Item No.30Supplying of 40mm& down size granite metal jelly and spreading to the TC yard etc., as per ISI and ISo (888*1.03)Cum1079.281079.2810.0FalseNoneNoneFalseNoneFalse10792.80
288433594346NoneCivil SR P-9 P-11.58Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction ofEngineer-in-charge. (Made of G.I. wire of dia 4 mm)Sqm797.68797.68100.0FalseNoneNoneFalseNoneFalse79768.00
288433694346NoneCivil Sr P-80 I-11.15.1Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitr ed, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications /and as per directions of the Engineer-in-Charge.Kg135.7135.7150.0FalseNoneNoneFalseNoneFalse20355.00
288433794346NoneCivil SR 90 I-2.2.1.1Spun Pole Concrete Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7352.587352.585.0FalseNoneNoneFalseNoneFalse36762.90
288433894346NoneP-12 I-5.14.7Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. FOUR POLE 100 A 25 kAEach9752.79752.740.0FalseNoneNoneFalseNoneFalse390108.00
288433994346NoneP-12 I-5.14.8Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 125 A 25 kAEach11884.9611884.969.0FalseNoneNoneFalseNoneFalse106964.640
288434094346NoneP-12 I-5.14.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 160 A 25 kAEach14827.8814827.887.0FalseNoneNoneFalseNoneFalse103795.160
288434194346NoneP-12 I-5.14.10Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 200 A 35 kAEach25121.0225121.024.0FalseNoneNoneFalseNoneFalse100484.080
288434294346NoneP-12 I-5.14.11Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 250 A 35 kAEach26585.426585.46.0FalseNoneNoneFalseNoneFalse159512.40
288434394346NoneP-12 I-5.14.12Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 320-400 A 50 kAEach34328.5634328.5612.0FalseNoneNoneFalseNoneFalse411942.720
288434494346NoneP-12 I-5.14.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short- icrcuit/Over Load. ForMicroprocessor MCCBS Facility for segregating Priority andNon-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between frontcover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all thepoles simultaneously and they shall have a single mechanism. 700-800 A 50 kAEach51358.3251358.324.0FalseNoneNoneFalseNoneFalse205433.280
288434594346NoneP-12 I-5.15Supplying and fixing of Shunt trip suitable for MCCB.CBCT (12/5.15)Each1784.161784.1625.0FalseNoneNoneFalseNoneFalse44604.00
288434694346NoneP-14 I-5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9812.889812.8813.0FalseNoneNoneFalseNoneFalse127567.440
288434794346NoneP-14 I-5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each595.9595.924.0FalseNoneNoneFalseNoneFalse14301.60
288434894346NoneP-14 I-5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each547.52547.5221.0FalseNoneNoneFalseNoneFalse11497.920
288434994346NoneP-14 I-5.35Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 Amps three phase 4 wire whole current class-1 Accuracy Energy Meter..Each6047.56047.51.0FalseNoneNoneFalseNoneFalse6047.50
288435094346NoneP-11 I-5.12.5Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 800 AEach64359.5664359.561.0FalseNoneNoneFalseNoneFalse64359.560
288435194346NoneP-11 I-5.12.8Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 400 AEach35669.0435669.042.0FalseNoneNoneFalseNoneFalse71338.080
288435294346NoneP-11 I-5.12.5Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 200 AEach14261.4814261.481.0FalseNoneNoneFalseNoneFalse14261.480
288435394346NoneP-14 I-5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9876.69876.612.0FalseNoneNoneFalseNoneFalse118519.20
288435494346NoneP-13 I-5.17.1Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SPEach617.14617.146.0FalseNoneNoneFalseNoneFalse3702.840
288435594346NoneP-13 I-5.17.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 6-32 Amps DPEach1301.541301.54168.0FalseNoneNoneFalseNoneFalse218658.720
288435694346NoneP-13 I-5.17.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. 50-63 Amps TPNEach2830.822830.8292.0FalseNoneNoneFalseNoneFalse260435.440
288435794346NoneP-15 I-5.42.2Fabricating supplying and mounting MS box made out …SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete14 SWGSq CM0.510.51790000.0FalseNoneNoneFalseNoneFalse402900.00
288435894346NoneP-15 I-5.40.1Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100 A 4 x 30 x 6 mm Aluminium Stripsm2612.522612.5250.0FalseNoneNoneFalseNoneFalse130626.00
288435994346NoneP-15 I-5.40.2Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250 A 4 x 30 x 10 mm Aluminium Stripsm3632.043632.0425.0FalseNoneNoneFalseNoneFalse90801.00
288436094346NoneP-15 I-5.40.3Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400 A 4 x 50 x 10 mm Aluminium Stripsm4715.284715.2825.0FalseNoneNoneFalseNoneFalse117882.00
288436194346NoneP-15 I-5.41.5Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 150 x 75 x 6 mm C channelm981.76981.7610.0FalseNoneNoneFalseNoneFalse9817.60
288436294346NoneP-15 I-5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 50x50x6mmm420.08420.08145.0FalseNoneNoneFalseNoneFalse60911.60
288436394346NoneP-15 I-5.41.3Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmm586.46586.4630.0FalseNoneNoneFalseNoneFalse17593.80
288436494346NoneP-3 I-2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 4 mm2m69.6269.62200.0FalseNoneNoneFalseNoneFalse13924.00
288436594346NoneP-3 I-2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 6mm2m102.66102.66250.0FalseNoneNoneFalseNoneFalse25665.00
288436694346NoneP-3 I-2.3.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 10 mm2m185.26185.26150.0FalseNoneNoneFalseNoneFalse27789.00
288436794346NoneP-3 I-2.3.7Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments . 16 mm2m375.24375.24100.0FalseNoneNoneFalseNoneFalse37524.00
288436894346NoneBESCOM P.No 16 P-410 I-49.05GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Diam451.94451.9450.0FalseNoneNoneFalseNoneFalse22597.00
288436994346NoneBESCOM P.No 16 P-411 I-49.05GI Pipe B - Class as per IS-1239 GI Pipe - 63 mm Diam489.7489.750.0FalseNoneNoneFalseNoneFalse24485.00
288437094346NoneBESCOM P.No 16 P-411 I-49.05GI Pipe B - Class as per IS-1239 GI Pipe - 100 mm Diam1803.041803.04120.0FalseNoneNoneFalseNoneFalse216364.80
288437194346None25 P-688 I-70.01Brass Cable Gland 25 mmNo90.8690.8680.0FalseNoneNoneFalseNoneFalse7268.80
288437294346None25 P-689 I-70.02Brass Cable Gland 32 mmNo109.74109.7480.0FalseNoneNoneFalseNoneFalse8779.20
288437394346None25 P-689 I-70.03Brass Cable Gland 40 mmNo169.92169.9280.0FalseNoneNoneFalseNoneFalse13593.60
288437494346None25 P-689 I-70.04Brass Cable Gland 45 mmNo226.56226.5630.0FalseNoneNoneFalseNoneFalse6796.80
288437594346NoneBESCOM P.No 9 P-215 I-32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km216461.56216461.560.35FalseNoneNoneFalseNoneFalse75761.5460
288437694346NoneBESCOM P.No 9 P-215 I-32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 . 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mmKm214113.36214113.360.3FalseNoneNoneFalseNoneFalse64234.0080
288437794346NoneBESCOM P.No 9 P-215 I-32.111.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm)Km286044.98286044.980.2FalseNoneNoneFalseNoneFalse57208.9960
288437894346NoneBESCOM P.No 9 P-215 I-32.141.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km606567.2606567.20.5FalseNoneNoneFalseNoneFalse303283.60
288437994346NoneBESCOM P.No 9 P-215 I-32.151.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 120 Sqmm, 3.5 Core, (23 GI Strips - 4 x 0.8 mm)Km746716.98746716.980.3FalseNoneNoneFalseNoneFalse224015.0940
288438094346NoneBESCOM P.No 9 P-215 I-32.161.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 150 Sqmm, 3.5 Core, (25 GI Strips - 4 x 0.8 mm)Km902347.18902347.180.3FalseNoneNoneFalseNoneFalse270704.1540
288438194346NoneBESCOM P.No 9 P-215 I-32.171.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 185 Sqmm, 3.5 Core, (28 GI Strips - 4 x 0.8 mm)Km1121938.11121938.10.4FalseNoneNoneFalseNoneFalse448775.240
288438294346NoneBESCOM P.No 9 P-215 I-32.191.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 300 Sqmm, 3.5 Core, (32 GI Strips - 4 x 0.8 mm)Km1752441.61752441.60.3FalseNoneNoneFalseNoneFalse525732.480
288438394346NoneBESCOM P.No 9 P-215 I-32.201.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 400 Sqmm, 3.5 Core, (39 GI Strips - 4 x 0.8 mm)Km2315524.622315524.620.3FalseNoneNoneFalseNoneFalse694657.3860
288438494346None9 P-230 I-31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 SqmmKm19067.6219067.621.0FalseNoneNoneFalseNoneFalse19067.620
288438594346None9 P-230 I-31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 SqmmKm27903.4627903.461.0FalseNoneNoneFalseNoneFalse27903.460
288438694346None9 P-230 I-31.07Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 SqmmKm28494.6428494.642.0FalseNoneNoneFalseNoneFalse56989.280
288438794346None2014-15 P-63 I-7.20 bSupply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. 50mm OD / 38mm IDm178.18178.181000.0FalseNoneNoneFalseNoneFalse178180.00
288438894346None2014-15 P-63 I-7.20 dSupply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. d) 77mm OD / 63mm IDm307.98307.98900.0FalseNoneNoneFalseNoneFalse277182.00
288438994346None2014-15 P-63 I-7.20 iSupply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. i) 145mm OD / 123mm IDm633.66633.66800.0FalseNoneNoneFalseNoneFalse506928.00
288439094346None2014-15 P-63 I-7.20 mSupply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in exisiting trench as per IS 14930 part -II suitable for drawing under ground cables. m) 200mm OD / 174mm IDm860.22860.22800.0FalseNoneNoneFalseNoneFalse688176.00
288439194346NoneP-14 I-5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motorKvar509.76509.76420.0FalseNoneNoneFalseNoneFalse214099.20
288439294346NoneP-15 I-5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage icroprocessor operation, relays LED display, self rogramming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor tank, measurement of network harmonics withindication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach22939.222939.23.0FalseNoneNoneFalseNoneFalse68817.60
288439394346NoneP-13 I-5.20.4Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker (ELMCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 63 A 4 poleEach3608.443608.4410.0FalseNoneNoneFalseNoneFalse36084.40
288439494346NoneP-14 I-5.24Supplying, fixing and wiring 0 to 30A Direct Reading AC analog type AmmeterEach493.24493.242.0FalseNoneNoneFalseNoneFalse986.480
288439594346NoneP-14 I-5.23Supplying, fixing and wiring 0 to 30V Direct Reading DC Voltmeter/Ammeter.Each732.78732.786.0FalseNoneNoneFalseNoneFalse4396.680
288439694346NoneP-12 I-5.13.2Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 40 AEach2508.682508.6830.0FalseNoneNoneFalseNoneFalse75260.40
288439794346NoneP-12 I-5.13.4Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 100 to 125 AEach10621.1810621.1810.0FalseNoneNoneFalseNoneFalse106211.80
288439894346None23 P-627 I-66.20Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 MtrRoll149.86149.8610.0FalseNoneNoneFalseNoneFalse1498.60
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17093700430000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17093700430000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17093700430000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17093703720000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17093703840000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17093703930000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17093704010000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidder.None
17093704100000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17093704180000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17093704260000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17093704340000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17093704500000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17093704590000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17093704670000NoneNoneELIGIBILITYAll the formats prescribed in the bid documents shall be filled in complete manner. (section 2 & 3 of the bid document) and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purpose.None
17093704750000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17093704880000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17093705040000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract Help Desk for more assistance Phone: 080-25501216/ 25501227)None
17093705160000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoide damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17093705270000NoneNoneELIGIBILITYSpecial Instructions to tenderers - asper bid document (F. Special Conditions of Contract Clause-6)None
17093705400000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17093705630000NoneNoneELIGIBILITYTotal value of Engineering works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21, 2021-22 & 2022-23.None
17093705750000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within weeks time from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17093706020000NoneNoneELIGIBILITYTenderer should have latest GST registration & upload latest GST/VAT clearance certificate in their nameNone
17093706440000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be Inclusive of GSTNone
17093706520000NoneNoneELIGIBILITYThe contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operationNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNone3.2aTo qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23)Clause ITT 3.2a:The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of Engineering works only) of Rs.303.24 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause ITT 3.2bTo qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23)The tenderer should have been Satisfactorily completed at least one Similar work of value not less than Rs.75.81 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(c): To qualify for award of this contract,each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one financial year,the following minimum quantities of work Sl.No Description of key items of works Quantity 1 Transformer 500 KVA TC-1 No 2.RMU-1 No 3.Span pole with structural work, DP with structural work-1No 4.11KVA HT UG cable-160mtr 5.700 A to 800A MCCB-3 Nos 6. LT UG cable 95sqmm to 400sqmm-600mts Note:The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/Semi Government/Government undertaking/ autonomous bodies of Government will be considered, for the clause 3.2 (c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT3.6 Tenderers who meet the above specified minimum qualifying criteria will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated as under Assessed available tender capacity(AxNx1.5-B)where A Maximum value of civil engineering works executed in any one year during the last five years i.e (2018-19-2022-23)(updated to2023-24 price level)taking into account the completed as well as works in progress .N Number of years prescribed for completion of the works for which tender are invited. B Value at 2023-24 price level, of existing commitments of and ongoing works to be Completed during the next 03 months. Note:(1)The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent(2)Tenderer shall submit the list of Ongoing works duly certified by the Auditor/Chartered Accountant.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by the officer not lessthan the rank of Executive EngineerOngoing commitments and Bids submitted for the works
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work 1)Site Engineer BE Civil with minimum experience of 5 years in the Constructions of building or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) 2)Electrical Engineer B.E. Electrical with minimum experience of 5 years in the Construction of buildings or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 (One) Note: 1) The tenderer shall submit list and photo identity proof such as Aadhar Card/Voter ID/Employee ID/Pass port/Driving License etc., for the key personnel such as project manager/site engineer to be deployed at each of the worksite. 2) The key personnel deployed at the site for this work should be working for a minimum period of one year with the tenderers and experience certificate has to be furnished in this regard.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneClass-I Registered in CEIG:Chairman LA & EB, Bangalore Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause ITT 3.3(b):Liquid assets and/or availability of credit facilities of not less than Rs.45.49 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Registration CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
ESI and PF certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709382816000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Health and Family Welfare Department, Engineering Wing, 3rd Floor Arogya Soudha 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone