| 2879750 | 94151 | None | Aldur01 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m depth( P 6 I.N:1.5.1) Volume-1 CSR-21-22) | Cum | 256.48 | 256.48 | 33.87 | False | None | None | False | None | False | 8686.9776 | 0 |
| 2879751 | 94151 | None | Aldur02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M10) Using 40 mm nominal size graded crushed coarse aggregates( P 15 I.N:2.1.2) Volume-1 CSR-21-22) | Cum | 5736.64 | 5736.64 | 3.24 | False | None | None | False | None | False | 18586.7136 | 0 |
| 2879752 | 94151 | None | Aldur03 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( P 9 I.N:5.2) Volume-2 CSR-21-22) | Cum | 6167.84 | 6167.84 | 6.0 | False | None | None | False | None | False | 37007.04 | 0 |
| 2879753 | 94151 | None | Aldur04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( P 9 I.N:5.4) Volume-2 CSR-21-22) | Cum | 5952.8 | 5952.8 | 6.0 | False | None | None | False | None | False | 35716.8 | 0 |
| 2879754 | 94151 | None | Aldur05 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.. (P 7 I.N:1.9) Volume-1 CSR-21-22) | Cum | 228.48 | 228.48 | 16.2 | False | None | None | False | None | False | 3701.376 | 0 |
| 2879755 | 94151 | None | Aldur06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates( P 16 I.N:2.3.1) Volume-1 CSR-21-22) | Cum | 6686.1 | 6686.1 | 8.21 | False | None | None | False | None | False | 54892.881 | 0 |
| 2879756 | 94151 | None | Aldur07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ( P 17 I.N:2.5.2) Volume-1 CSR-21-22) | Cum | 10960.04 | 10960.04 | 3.66 | False | None | None | False | None | False | 40113.7464 | 0 |
| 2879757 | 94151 | None | Aldur08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.( P 17 I.N:6.33) Volume-2 CSR-21-22) | Sqm | 1184.96 | 1184.96 | 92.07 | False | None | None | False | None | False | 109099.2672 | 0 |
| 2879758 | 94151 | None | Aldur09 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P 84I.N:11.32) PWD SR-21-22) | Kg | 100.8 | 100.8 | 1270.0 | False | None | None | False | None | False | 128016.0 | 0 |
| 2879759 | 94151 | None | Aldur10 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P 84I.N:11.32) PWD SR-21-22) | Cum | 9755.64 | 9755.64 | 11.29 | False | None | None | False | None | False | 110141.1756 | 0 |
| 2879760 | 94151 | None | Aldur11 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on speciallydesigned pipe shaft with brackets, side guides and arrangements forinside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm longwire springs manufactured from high tensile steel wire of adequatestrength conforming to IS: 4454 - part 1 and M.S. top cover of requiredthickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm
thick top cover including cost of materials, labour, usage charges ofmachinery complete as per specifications and as per directions of theEngineer-in-Charge.( P 76 I.N:11.6.1) Volume-2 CSR-21-22) | Sqm | 2811.2 | 2811.2 | 21.87 | False | None | None | False | None | False | 61480.944 | 0 |
| 2879761 | 94151 | None | Aldur12 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge( P 42 I.N:8.7) Volume-2 CSR-21-22) | Cum | 342.72 | 342.72 | 266.03 | False | None | None | False | None | False | 91173.8016 | 0 |
| 2879762 | 94151 | None | Aldur13 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6( M10) Using 20 mm nominal size graded crushed coarse aggregates( P 15 I.N:2.1.4) Volume-1 CSR-21-22) | Cum | 6296.64 | 6296.64 | 2.7 | False | None | None | False | None | False | 17000.928 | 0 |
| 2879763 | 94151 | None | Aldur14 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete,Size of Tile 600x600 mm( P.61 I.No.9.17.2 CSR SR 21-22) | Sqm | 1228.64 | 1228.64 | 37.1 | False | None | None | False | None | False | 45582.544 | 0 |
| 2879764 | 94151 | None | Aldur15 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coatsapplied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surfaceeven and sand paper smooth, cost of materials, labour complete as perspecifications and as per directions of Engineer-in-charge.( P 46 I.N:8.33.1 Volume-2 CSR-21-22) | Sqm | 132.16 | 132.16 | 253.41 | False | None | None | False | None | False | 33490.6656 | 0 |
| 2879765 | 94151 | None | Aldur16 | Painting with synthetic enamel paint of approved brand andmanufacture to give an even shade :Two coats on new work afterthoroughly brooming the surface to remove all dirt, dust, mortar dropsand foreign matter including preparing the surface even and sand papersmooth, cost of materials, labour complete as per specifications and asper directions of Engineer-in-charge.( P 48 I.N:8.40) Volume-2 CSR-21-22) | Sqm | 100.8 | 100.8 | 49.21 | False | None | None | False | None | False | 4960.368 | 0 |
| 2879766 | 94151 | None | Aldur17 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick(I.no.1.1.2)Wall | m | 80.0 | 80.0 | 40.0 | False | None | None | False | None | False | 3200.0 | 0 |
| 2879767 | 94151 | None | Aldur18 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thick(I.no.1.2.2) | m | 70.0 | 70.0 | 40.0 | False | None | None | False | None | False | 2800.0 | 0 |
| 2879768 | 94151 | None | Aldur19 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box (I.no.1.5.2) | No | 51.0 | 51.0 | 12.0 | False | None | None | False | None | False | 612.0 | 0 |
| 2879769 | 94151 | None | Aldur20 | Supplying and flush mounting powder coated / galvanizedmetal box suitable for mounting modular switch plates. The boxshould be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(I.no.3.4)10-12 Way (I.no.3.4.5) | No | 325.0 | 325.0 | 3.0 | False | None | None | False | None | False | 975.0 | 0 |
| 2879770 | 94151 | None | Aldur21 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc,200 x 90 x 65 mm,(I.no.1.4.5) | Each | 169.0 | 169.0 | 9.0 | False | None | None | False | None | False | 1521.0 | 0 |
| 2879771 | 94151 | None | Aldur22 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.Short point upto 3m from tapping point to out let via switch box(I.N:2.2.1) | Point | 251.0 | 251.0 | 9.0 | False | None | None | False | None | False | 2259.0 | 0 |
| 2879772 | 94151 | None | Aldur23 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1mm2 | m | 18.0 | 18.0 | 30.0 | False | None | None | False | None | False | 540.0 | 0 |
| 2879773 | 94151 | None | Aldur24 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5mm2 | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 |
| 2879774 | 94151 | None | Aldur25 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5mm2 | m | 40.0 | 40.0 | 50.0 | False | None | None | False | None | False | 2000.0 | 0 |
| 2879775 | 94151 | None | Aldur26 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4mm2 | m | 59.0 | 59.0 | 60.0 | False | None | None | False | None | False | 3540.0 | 0 |
| 2879776 | 94151 | None | Aldur27 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting inBrick/Stone/C.C wall(I.no.3.4.3)10-12Way | Each | 277.0 | 277.0 | 9.0 | False | None | None | False | None | False | 2493.0 | 0 |
| 2879777 | 94151 | None | Aldur28 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One WaySwitch(I.no.3.6.1) | Each | 88.0 | 88.0 | 27.0 | False | None | None | False | None | False | 2376.0 | 0 |
| 2879778 | 94151 | None | Aldur29 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket(I.no.3.6.3) | Each | 162.0 | 162.0 | 9.0 | False | None | None | False | None | False | 1458.0 | 0 |
| 2879779 | 94151 | None | Aldur30 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator Two Module(I.no.3.6.4) | Each | 313.0 | 313.0 | 3.0 | False | None | None | False | None | False | 939.0 | 0 |
| 2879780 | 94151 | None | Aldur31 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP Switch(I.no.3.6.4) | Each | 375.0 | 375.0 | 3.0 | False | None | None | False | None | False | 1125.0 | 0 |
| 2879781 | 94151 | None | Aldur32 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board.(I.no.3.14.6)6A Lamp Holder | Each | 63.0 | 63.0 | 12.0 | False | None | None | False | None | False | 756.0 | 0 |
| 2879782 | 94151 | None | Aldur33 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.(I.no.5.18.9)II - Double Door | Set | 2067.0 | 2067.0 | 3.0 | False | None | None | False | None | False | 6201.0 | 0 |