1709025120000 | 0 | None | None | Buildings | Construction of SCP,TSP PK quarters, Extension of Library building, Physiotherapy building and Handicap commercial complex at Ullala CMC limits under Amruth Nagarothana Phase 4 scheme | 27978992.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2822875 | 91211 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled + sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.PWD SR 2021-22 Vol 1 P.No 05 I.No 1.4.1 | Cum | 271.04 | 271.04 | 743.14 | False | None | None | False | None | False | 201420.6656 | 0 | 2822876 | 91211 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.PWD SR 2021-22 Vol 1 P.No 15 I.No 2.1.3 | Cum | 6707.68 | 6707.68 | 89.92 | False | None | None | False | None | False | 603154.5856 | 0 | 2822877 | 91211 | None | code03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand).PWD SR 2021-22 Vol 2 P.No 9 I.No 5.4 | Cum | 7155.68 | 7155.68 | 140.339 | False | None | None | False | None | False | 1004220.97552 | 0 | 2822878 | 91211 | None | code04 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For drain form works consider 5%.PWD SR 2021-22 Vol 1 P.No 16 I.No 2.4.2 | Cum | 7435.84 | 7435.84 | 124.69 | False | None | None | False | None | False | 927174.8896 | 0 | 2822879 | 91211 | None | code05 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For plinth beam and slab form works consider 50%.PWD SR 2021-22 Vol 1 P.No 16 I.No 2.4.2 | Cum | 10622.64 | 10622.64 | 185.309 | False | None | None | False | None | False | 1968470.79576 | 0 | 2822880 | 91211 | None | code06 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For column form works consider 70%.PWD SR 2021-22 Vol 1 P.No 16 I.No 2.4.2 | Cum | 12038.99 | 12038.99 | 51.05 | False | None | None | False | None | False | 614590.4395 | 0 | 2822881 | 91211 | None | code07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For column form works consider 60%.PWD SR 2021-22 Vol 1 P.No 16 I.No 2.4.2 | Cum | 11330.81 | 11330.81 | 91.28 | False | None | None | False | None | False | 1034276.3368 | 0 | 2822882 | 91211 | None | code08 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Form Work
As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For column form works consider 45%.PWD SR 2021-22 Vol 1 P.No 16 I.No 2.4.2 | Cum | 12038.99 | 12038.99 | 2.9299 | False | None | None | False | None | False | 35273.036801 | 0 | 2822883 | 91211 | None | code09 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings.As per SR 2023-24 Vol 1 Page no.18 slno.2.11 A | Tonne | 100191.84 | 100191.84 | 53.3799 | False | None | None | False | None | False | 5348230.400016 | 0 | 2822884 | 91211 | None | code10 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges.PWD SR 2021-22 Vol 2 P.No 100 I.No 12.15
complete as per specifications. ( excluding cost of fixtures ) | Sqm | 8337.28 | 8337.28 | 92.93 | False | None | None | False | None | False | 774783.4304 | 0 | 2822885 | 91211 | None | code11 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.PWD SR 2021-22 Vol 2 P.No 99 I.No 12.11 | Cum | 154642.88 | 154642.88 | 1.78 | False | None | None | False | None | False | 275264.3264 | 0 | 2822886 | 91211 | None | code12 | Providing and constructing laterite stone masonry including cost and coveyance of all materials curing etc. as per specifications IS 3620/1979 having compressive strength not less than 3.5N /m2 for saturated dry samples- For Super structure in CM 1:6.PWD SR 2023-24 Vol 2 P.No 09 I.No 5.7 | Cum | 7565.6 | 7565.6 | 408.82 | False | None | None | False | None | False | 3092968.592 | 0 | 2822887 | 91211 | None | code13 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 81mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm x 57mm and mesh sash of size with GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-2.0mm. Maximum possible size 1519mm x 1519mm (The cost is inclusive of all fixtures and separate charges forminor T&P's shall not be made).PWD SR 2021-22 Vol 2 P.No 109 I.No 12.87 | Sqm | 7337.12 | 7337.12 | 264.69 | False | None | None | False | None | False | 1942062.2928 | 0 | 2822888 | 91211 | None | code14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.PWD SR 2021-22 Vol 2 P.No 17 I.No 6.33 | Sqm | 1378.72 | 1378.72 | 258.12 | False | None | None | False | None | False | 355875.2064 | 0 | 2822889 | 91211 | None | code15 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.PWD SR 2021-22 Vol 2 P.No 83 I.No 11.25.1 | Kgs | 126.56 | 126.56 | 6534.15 | False | None | None | False | None | False | 826962.024 | 0 | 2822890 | 91211 | None | code16 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.PWD SR 2021-22 Vol 2 P.No 83 I.No 11.28 | Kgs | 632.8 | 632.8 | 826.4535 | False | None | None | False | None | False | 522979.7748 | 0 | 2822891 | 91211 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24 Vol 2 P.No 41 I.No 8.2.2 | Sqm | 312.48 | 312.48 | 5545.49 | False | None | None | False | None | False | 1732854.7152 | 0 | 2822892 | 91211 | None | code18 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops.PWD SR 2023-24 Vol 2 P.No 45 I.No 8.25
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 153.44 | 153.44 | 4030.94 | False | None | None | False | None | False | 618507.4336 | 0 | 2822893 | 91211 | None | code19 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2021-22 Vol 2 P.No 46 I.No 8.30 | Sqm | 194.88 | 194.88 | 2879.5499 | False | None | None | False | None | False | 561166.684512 | 0 | 2822894 | 91211 | None | code20 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting.PWD SR 2021-22 Vol 2 P.No 60 I.No 9.12.2.PWD SR 2021-22 Vol 2 P.No 60 I.No 9.12.2
the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1282.4 | 1282.4 | 639.24 | False | None | None | False | None | False | 819761.376 | 0 | 2822895 | 91211 | None | code21 | Providing & fixing and laying brick tiles over mumty roofs, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement, over 12 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) and finished neat: With common burnt clay Non Modular brick tiles of class designation 5.0. PWD SR 2023-24 Vol 2 P.No 22 I.No 7.15 | Sqm | 730.24 | 730.24 | 217.87 | False | None | None | False | None | False | 159097.3888 | 0 | 2822896 | 91211 | None | code22 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White,Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 995.68 | 995.68 | 52.06 | False | None | None | False | None | False | 51835.1008 | 0 | 2822897 | 91211 | None | code23 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.PWD SR 2021-22 Vol 2 P.No 71 I.No 10.14 | Sqm | 1238.72 | 1238.72 | 231.48 | False | None | None | False | None | False | 286738.9056 | 0 | 2822898 | 91211 | None | code24 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.PWD SR 2021-22 Vol 2 P.No 131 I.No 14.3.1 | No | 6694.24 | 6694.24 | 17.0 | False | None | None | False | None | False | 113802.08 | 0 | 2822899 | 91211 | None | code25 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931.PWD SR 2021-22 Vol 2 P.No 119 I.No 13.12 | No | 711.2 | 711.2 | 28.0 | False | None | None | False | None | False | 19913.6 | 0 | 2822900 | 91211 | None | code26 | Providing and fixing CPVC pipes, having thermal stability for hot and cold water suply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge . Concealed work , including cutting chases and making good the wall etc.,32 mm dia nominal pipes.PWD SR 2023-24 Vol 2 P.No 122 I.No 13.32.4 | Cum | 623.84 | 623.84 | 450.0 | False | None | None | False | None | False | 280728.0 | 0 | 2822901 | 91211 | None | code27 | Providing and placing on terrace (at all floor levels) polythelene water storage tank IS 12701 marked with cover and suitable locking arrangements and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support of tank.PWD SR 2023-24 Vol 2 P.No 122 I.No 13.32.4 | l | 10.08 | 10.08 | 8000.0 | False | None | None | False | None | False | 80640.0 | 0 | 2822902 | 91211 | None | code28 | Providing and fixing on wallface unplastisised rigid PVC rain water pipes confirming to IS 13592 Type A including jointing with seal ring confirming to IS 5382 leaving 10mm gap for thermal expansion single soaked pipes 100 mm dia | m | 325.92 | 325.92 | 232.8 | False | None | None | False | None | False | 75874.176 | 0 | 2822903 | 91211 | None | code29 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.PWD SR 2021-22 Vol 2 P.No 105 I.No 12.58 | Nos | 134.4 | 134.4 | 48.0 | False | None | None | False | None | False | 6451.2 | 0 | 2822904 | 91211 | None | code30 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.PWD SR 2021-22 Vol 2 P.No 107 I.No 12.59 | Nos | 985.6 | 985.6 | 7.0 | False | None | None | False | None | False | 6899.2 | 0 | 2822905 | 91211 | None | code31 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1178.24 | 1178.24 | 48.0 | False | None | None | False | None | False | 56555.52 | 0 | 2822906 | 91211 | None | code32 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 265.44 | 265.44 | 48.0 | False | None | None | False | None | False | 12741.12 | 0 | 2822907 | 91211 | None | code33 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.PWD SR 2021-22 Vol 2 P.No 105 I.No 12.63 | Nos | 145.6 | 145.6 | 48.0 | False | None | None | False | None | False | 6988.8 | 0 | 2822908 | 91211 | None | code34 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type).PWD SR 2021-22 Vol 2 P.No 107 I.No 12.75.1 | Nos | 308.0 | 308.0 | 144.0 | False | None | None | False | None | False | 44352.0 | 0 | 2822909 | 91211 | None | code35 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Prestressed / RCC grade M-20 & above.PWD SR 2021-22 Vol 3 P.No 8 I.No 2.8B | Cum | 1240.96 | 1240.96 | 253.0 | False | None | None | False | None | False | 313962.88 | 0 | 2822910 | 91211 | None | code36 | Concealed Conduit System- Supplying heavy gauge PVC conduit pipe 19/20mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick.1.2.1 page no.02 | m | 66.0 | 66.0 | 675.0 | False | None | None | False | None | False | 44550.0 | 0 | 2822911 | 91211 | None | code37 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mmthick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick.1.3.1 page no.02 | m | 68.0 | 68.0 | 675.0 | False | None | None | False | None | False | 45900.0 | 0 | 2822912 | 91211 | None | code38 | Point wiring using Copper wire without switch.-Supplying and wiring adopting loop system in existing PVC Conduit /casing caping casing caping using 2x1.5Sqmm (Phase & Neutural) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire without control switch shall be fixed on the exisiting plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet. - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 379.0 | 379.0 | 126.0 | False | None | None | False | None | False | 47754.0 | 0 | 2822913 | 91211 | None | code39 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6m upto 10m from tapping point to out let via.2.2.3 page no.05
switch box | Point | 555.0 | 555.0 | 121.0 | False | None | None | False | None | False | 67155.0 | 0 | 2822914 | 91211 | None | code40 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2.2.3.1 page no.05 | m | 19.0 | 19.0 | 675.0 | False | None | None | False | None | False | 12825.0 | 0 | 2822915 | 91211 | None | code41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2.2.3.4 page no.05 | m | 63.0 | 63.0 | 675.0 | False | None | None | False | None | False | 42525.0 | 0 | 2822916 | 91211 | None | code42 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2 Way.3.4.1 page no.08 | Each | 138.0 | 138.0 | 150.0 | False | None | None | False | None | False | 20700.0 | 0 | 2822917 | 91211 | None | code43 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 way.3.4.3 page no.08 | Each | 177.0 | 177.0 | 138.0 | False | None | None | False | None | False | 24426.0 | 0 | 2822918 | 91211 | None | code44 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 2 Module.3.5.1 page no.08 | Each | 137.0 | 137.0 | 108.0 | False | None | None | False | None | False | 14796.0 | 0 | 2822919 | 91211 | None | code45 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 Module.3.5.4 page no.08 | Each | 234.0 | 234.0 | 108.0 | False | None | None | False | None | False | 25272.0 | 0 | 2822920 | 91211 | None | code46 | Wiring for lighting/power circuit using 2.5 sqmm one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest ammendments. 2.5 mm2.2.3.3 page no.05 | m | 42.0 | 42.0 | 550.0 | False | None | None | False | None | False | 23100.0 | 0 | 2822921 | 91211 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps one way Switch.3.6.1 page no.09 | Each | 102.0 | 102.0 | 108.0 | False | None | None | False | None | False | 11016.0 | 0 | 2822922 | 91211 | None | code48 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module.3.5.6 page no.05 | Each | 344.0 | 344.0 | 108.0 | False | None | None | False | None | False | 37152.0 | 0 | 2822923 | 91211 | None | code49 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI GT 80. Power Input: 220-240V@ 50/60Hz & Power factor GT 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W.11.3.2 page no.43 | Each | 690.0 | 690.0 | 78.0 | False | None | None | False | None | False | 53820.0 | 0 | 2822924 | 91211 | None | code50 | Supplying of feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI GT 80. Power Input: 220-240V@ 50/60Hz & Power factor GT 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W.11.3.1 page no.43 | Each | 551.0 | 551.0 | 66.0 | False | None | None | False | None | False | 36366.0 | 0 | 2822925 | 91211 | None | code51 | Supplying and fixing 6-32Amps SP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP.5.18.1 page no.17 | Each | 415.0 | 415.0 | 84.0 | False | None | None | False | None | False | 34860.0 | 0 | 2822926 | 91211 | None | code52 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.6.1 page no.30 | No | 1492.0 | 1492.0 | 27.0 | False | None | None | False | None | False | 40284.0 | 0 | 2822927 | 91211 | None | code53 | LT AC 3 Phase 4 Wire, 10-60 Amps smart Energy Meter, Class 1.0 Accuracy with RF communication Module. Bescom Part III : Common SR-2023-24, Page No. 24, IT No. 53.17 | No | 3282.0 | 3282.0 | 20.0 | False | None | None | False | None | False | 65640.0 | 0 | 2822928 | 91211 | None | code54 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse).sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 1000x1000 mmPWD SR 2023-24 Vol 2 P.No 60 I.No 9.12.4 | Sqm | 2054.08 | 2054.08 | 376.75 | False | None | None | False | None | False | 773874.64 | 0 | 2822929 | 91211 | None | code55 | Newly Constructed Roof/Bathroom/Toilet/balcony/utility with Cementatius Waterproof coating - Below 500 m2 Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (5 Liquid :7 Powder) to the RCC surface like Roof, bathroom, toilet, balcony & utility area applied @ 2.2kg/m2 in 2 coats to achieve 1.2mm DFT, having Elongation at break GT120% as per ASTM D 412, Tensile strength GT 1N/mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.PWD SR 2023-24 Vol 2 P.No 151 I.No 15.11 | Sqm | 588.0 | 588.0 | 735.45 | False | None | None | False | None | False | 432444.6 | 0 | 2822930 | 91211 | None | code56 | Providing and fixing CPVC pipes, having thermal stability for hot and cold water suply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge . Concealed work , including cutting chases and making good the wall etc.,25 mm dia nominal pipes.PWD SR 2023-24 1st corrigendum 13.32.3 | m | 534.24 | 534.24 | 100.0 | False | None | None | False | None | False | 53424.0 | 0 | 2822931 | 91211 | None | code57 | Providing and fixing CPVC pipes, having thermal stability for hot and cold water suply, including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge . Concealed work , including cutting chases and making good the wall etc.,20 mm dia nominal pipes.PWD SR 2023-24 1st corrigendum 13.32.2 | m | 424.48 | 424.48 | 100.0 | False | None | None | False | None | False | 42448.0 | 0 | 2822932 | 91211 | None | code58 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm.PWD SR 2023-24 Vol 3 P.No 125 I.No 14.7 A
with a 15 mm CP Brass single hole basin mixer | Each | 4615.52 | 4615.52 | 4.0 | False | None | None | False | None | False | 18462.08 | 0 | 2822933 | 91211 | None | code59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.PWD SR 2023-24 Vol 2 P.No 105 I.No 12.59 | Nos | 1247.68 | 1247.68 | 11.0 | False | None | None | False | None | False | 13724.48 | 0 | 2822934 | 91211 | None | code60 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern.PWD SR 2023-24 Vol 2 P.No 124 I.No 14.5.1 | Each | 9679.04 | 9679.04 | 2.0 | False | None | None | False | None | False | 19358.08 | 0 | 2822935 | 91211 | None | code61 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm.PWD SR 2023-24 Vol 2 P.No 129 I.No 14.32.4 | Each | 1933.12 | 1933.12 | 4.0 | False | None | None | False | None | False | 7732.48 | 0 | 2822936 | 91211 | None | code62 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA
& for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as
per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification).PWD SR 2023-24 Vol 3 P.No 51 I.No 6.8.2 | Sqm | 1300.32 | 1300.32 | 81.0 | False | None | None | False | None | False | 105325.92 | 0 | 2822937 | 91211 | None | code63 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin- charge.Of area beyond 3 m².PWD SR 2023-24 Vol 2 P.No 188 I.No 19.12.2 | Sqm | 293.44 | 293.44 | 137.0 | False | None | None | False | None | False | 40201.28 | 0 | 2822938 | 91211 | None | code64 | Providing and supplying 'Acoustical Wall Paneling' with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class A, as per ASTM E-84, fabric with option of colors - as per the choice of the Architect/Engineer incharge of the size 600x600mm, 600x1200mm & 600x1800mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel lmpaler sand
construction adhesives as per the instructions laid down by the certified manufacturer.PWD SR 2023-24 Vol 2 P.No 32 I.No 7.51 | Sqm | 6414.24 | 6414.24 | 54.0 | False | None | None | False | None | False | 346368.96 | 0 | 2822939 | 91211 | None | code65 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(PWD SR 2023-24, Volume- 2, Page no. 82, Item no. 11.16.2 | Kg | 164.64 | 164.64 | 533.33 | False | None | None | False | None | False | 87807.4512 | 0 | 2822940 | 91211 | None | code66 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (PWD SR 2023-24, Volume- 2, Page no. 26, Item no. 7.38). | Sqm | 636.16 | 636.16 | 39.0 | False | None | None | False | None | False | 24810.24 | 0 | 2822941 | 91211 | None | code67 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth).(PWD SR 2023-24, Volume- 2, Page no. 27, Item no. 7.39.6) | m | 1202.88 | 1202.88 | 31.0 | False | None | None | False | None | False | 37289.28 | 0 | 2822942 | 91211 | None | code68 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm).(PWD SR 2023-24, Volume- 2, Page no. 27, Item no. 7.39.1) | m | 505.12 | 505.12 | 27.5 | False | None | None | False | None | False | 13890.8 | 0 | 2822943 | 91211 | None | code69 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model 48" Sweep (1200 mm) Regular model.6.3.1 page no.30 | No | 2984.0 | 2984.0 | 53.0 | False | None | None | False | None | False | 158152.0 | 0 | 2822944 | 91211 | None | code70 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.PWD SR 2023-24 Vol 2 P.No 78 I.No 11.6.1 | Sqm | 2948.96 | 2948.96 | 45.72 | False | None | None | False | None | False | 134826.4512 | 0 | 2822945 | 91211 | None | code71 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all otherappurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Form Work As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate. For chejjas form works consider 45%.PWD SR 2023-24 Vol 1 P.No 17 I.No 2.4.2 | Cum | 10268.55 | 10268.55 | 5.18 | False | None | None | False | None | False | 53191.089 | 0 | 2822946 | 91211 | None | code72 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam.PWD SR 2023-24 Vol 2 P.No 104 I.No 12.55.2 | Sqm | 2649.92 | 2649.92 | 23.0 | False | None | None | False | None | False | 60948.16 | 0 | 2822947 | 91211 | None | code73 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm.PWD SR 2023-24 Vol 2 P.No 126 I.No 14.10.1.1 | Each | 6292.16 | 6292.16 | 6.0 | False | None | None | False | None | False | 37752.96 | 0 | 2822948 | 91211 | None | code74 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.PWD SR 2023-24 Vol 2 P.No 13 I.No 6.2 | Cum | 8935.36 | 8935.36 | 0.5 | False | None | None | False | None | False | 4467.68 | 0 | 2822949 | 91211 | None | code75 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.PWD SR 2023-24 Vol 1 P.No 7 I.No 1.11 | Cum | 484.96 | 484.96 | 180.99 | False | None | None | False | None | False | 87772.9104 | 0 |
|