createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709389794851
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2740.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-03-2024 16:00:00
tenderQueryClose11-03-2024 11:00:00
technicalBidOpen19-03-2024 16:30:00
publishedDate02-03-2024 20:26:15
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate12-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonGnanesh Kumar V P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843360
tenderSupplierListNone
tenderSchedule
createdTs1709389794881
version7
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT375
titleConstruction of District Integrated Public Health Laboratory on existing MCH Diagnostic Centre at Second Floor at Chitradurga
descriptionConstruction of District Integrated Public Health Laboratory on existing MCH Diagnostic Centre at Second Floor at Chitradurga
categoryWORKS
categoryTextWorks
ecv10925273.47
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount11100000.0
groupOverheadTotal0.0
fileNumberAEE/HFWD/CHITRADURGA/DIPHL/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17093897950000NoneNoneBuildingsPROPOSED CONSTRUCTION OF DIPHL ON EXISTING MCH DIAGNOSTIC CENTRE AT SECOND FLOOR AT CHITRADURGA.10925273.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289421194774NoneV-2 Item No 19.61Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all lead Cum714.08714.0883.125FalseNoneNoneFalseNoneFalse59357.90
289421294774NoneV-3 Item No 2.7BDismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead.Cement Concrete Grade M-15 & M-20 ---- etc., complete with all lead Cum1156.651156.658.253FalseNoneNoneFalseNoneFalse9545.832450
289421394774NoneV-2 Item No 19.7.3Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.In cement mortar ---- etc., complete with all lead Cum1275.661275.6632.292FalseNoneNoneFalseNoneFalse41193.612720
289421494774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS ---- etc., complete with all lead Cum14421.6414421.6421.492FalseNoneNoneFalseNoneFalse309949.886880
289421594774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS ---- etc., complete with all lead Cum13573.3213573.3243.5093FalseNoneNoneFalseNoneFalse590565.6518760
289421694774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB ---- etc., complete with all lead Cum12724.9812724.9881.634FalseNoneNoneFalseNoneFalse1038791.017320
289421794774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC STAIRCASE ---- etc., complete with all lead Cum13136.813136.84.9212FalseNoneNoneFalseNoneFalse64648.820160
289421894774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork LINTELS ---- etc., complete with all lead Cum13573.3213573.322.028FalseNoneNoneFalseNoneFalse27526.692960
289421994774NoneV-1 Item No 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead Cum11917.9311917.936.3735FalseNoneNoneFalseNoneFalse75958.9268550
289422094774NoneV-1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead Tonne110900.55110900.5517.0FalseNoneNoneFalseNoneFalse1885309.350
289422194774None18-19 SR Item No 4.21Extra for providing throating or drip moulding to RCC chejjas with plastering (labour charges only) as per specifications. ---- etc., complete with all lead m38.9438.9474.8FalseNoneNoneFalseNoneFalse2912.7120
289422294774NoneData RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead m86.1486.1474.8FalseNoneNoneFalseNoneFalse6443.2720
289422394774NoneV-2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead Sqm1624.021624.02803.6FalseNoneNoneFalseNoneFalse1305062.4720
289422494774NoneV-2 Item No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead Sqm1368.631368.6330.168FalseNoneNoneFalseNoneFalse41288.829840
289422594774NoneV-2 Item No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all lead Cum122501.75122501.751.2525FalseNoneNoneFalseNoneFalse153433.4418750
289422694774NoneV-2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead Nos1259.541259.5413.0FalseNoneNoneFalseNoneFalse16374.020
289422794774NoneV-2 Item No 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., complete with all lead Nos681.84681.8426.0FalseNoneNoneFalseNoneFalse17727.840
289422894774NoneV-2 Item No 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., complete with all lead Nos464.9464.913.0FalseNoneNoneFalseNoneFalse6043.70
289422994774NoneV-2 Item No 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., complete with all lead Nos185.96185.9617.0FalseNoneNoneFalseNoneFalse3161.320
289423094774NoneV-2 Item No 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., complete with all lead Nos86.7886.7843.0FalseNoneNoneFalseNoneFalse3731.540
289423194774NoneV-2 Item No 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., complete with all lead Nos123.97123.9713.0FalseNoneNoneFalseNoneFalse1611.610
289423294774NoneV-2 Item No 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all lead Nos1304.171304.174.0FalseNoneNoneFalseNoneFalse5216.680
289423394774NoneV-2 Item No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., complete with all lead Nos74.3974.3978.0FalseNoneNoneFalseNoneFalse5802.420
289423494774None2018-19 SRProviding & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ---- etc., complete with all lead m15.015.092.4FalseNoneNoneFalseNoneFalse1386.00
289423594774NoneV-2 Item No 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., complete with all lead Sqm4118.314118.3136.0FalseNoneNoneFalseNoneFalse148259.160
289423694774NoneV-2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead Sqm8348.198348.1936.0FalseNoneNoneFalseNoneFalse300534.840
289423794774NoneV-2 Item No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead Sqm7086.177086.176.66FalseNoneNoneFalseNoneFalse47193.89220
289423894774NoneV-2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead Kgs208.27208.27895.86FalseNoneNoneFalseNoneFalse186580.76220
289423994774NoneV-2 Item No 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., complete with all lead m870.27870.2720.4FalseNoneNoneFalseNoneFalse17753.5080
289424094774NoneV-2 Item No 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., complete with all lead Sqm4320.384320.387.56FalseNoneNoneFalseNoneFalse32662.07280
289424194774NoneV-2 Item No 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., complete with all lead Nos1381.041381.0413.0FalseNoneNoneFalseNoneFalse17953.520
289424294774NoneV-2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead Sqm386.79386.79652.362FalseNoneNoneFalseNoneFalse252327.097980
289424394774NoneV-2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm261.58261.58954.913FalseNoneNoneFalseNoneFalse249786.142540
289424494774NoneV-2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead Sqm123.97123.971607.275FalseNoneNoneFalseNoneFalse199253.881750
289424594774NoneV-2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead Sqm432.66432.66518.94FalseNoneNoneFalseNoneFalse224524.58040
289424694774NoneV-2 Item No 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., complete with all lead m47.1147.11972.0FalseNoneNoneFalseNoneFalse45790.920
289424794774None18-19 SR Item No 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., complete with all lead Sqm283.2283.210.0FalseNoneNoneFalseNoneFalse2832.00
289424894774NoneV-2 Item No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., complete with all lead m64.4664.46624.0FalseNoneNoneFalseNoneFalse40223.040
289424994774NoneV-2 Item No 9.17.2Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..).Size of Tile 600x600 mm ---- etc., complete with all lead Sqm1456.661456.66394.5711FalseNoneNoneFalseNoneFalse574755.9385260
289425094774NoneV-2 Item No 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm365.72365.7240.464FalseNoneNoneFalseNoneFalse14798.494080
289425194774NoneV-2 Item No 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., complete with all lead Sqm762.42762.42162.896FalseNoneNoneFalseNoneFalse124195.168320
289425294774NoneV-2 Item No 7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., complete with all lead Sqm2500.492500.497.14FalseNoneNoneFalseNoneFalse17853.49860
289425394774NoneV-2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all lead Sqm1102.11102.123.8FalseNoneNoneFalseNoneFalse26229.980
289425494774NoneV-2 Item No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., complete with all lead Sqm1796.341796.3440.464FalseNoneNoneFalseNoneFalse72687.101760
289425594774NoneV-2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm157.45157.45954.913FalseNoneNoneFalseNoneFalse150351.051850
289425694774NoneV-2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm193.39193.39518.94FalseNoneNoneFalseNoneFalse100357.80660
289425794774NoneV-2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm61.9961.9942.66FalseNoneNoneFalseNoneFalse2644.49340
289425894774NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm142.57142.5742.66FalseNoneNoneFalseNoneFalse6082.03620
289425994774NoneV-2 Item No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm65.765.786.4FalseNoneNoneFalseNoneFalse5676.480
289426094774NoneV-2 Item No 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., complete with all lead Sqm839.29839.2986.4FalseNoneNoneFalseNoneFalse72514.6560
289426194774NoneV-2 Item No 11.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all lead Kgs700.44700.44120.54FalseNoneNoneFalseNoneFalse84431.03760
289426294774NoneV-2 Item No 10.19Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. ---- etc., complete with all lead Sqm4471.624471.628.16FalseNoneNoneFalseNoneFalse36488.41920
289426394774NoneV-2 Item No 12.92Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead Sqm7741.987741.984.32FalseNoneNoneFalseNoneFalse33445.35360
289426494774NoneV-2 Item No 12.83.1Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance +/-1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge.48x40 mm PVC Extruded section ---- etc., complete with all lead m245.46245.4613.2FalseNoneNoneFalseNoneFalse3240.0720
289426594774NoneV-2 Item No 12.91Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size - 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead Sqm7515.117515.1110.8FalseNoneNoneFalseNoneFalse81163.1880
289426694774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS ---- etc., complete with all lead Cum14563.0414563.041.08FalseNoneNoneFalseNoneFalse15728.08320
289426794774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC BEAMS and LINTELS TF ---- etc., complete with all lead Cum13706.3813706.382.556FalseNoneNoneFalseNoneFalse35033.507280
289426894774NoneV-1 Item No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork RCC SLAB ---- etc., complete with all lead Cum12849.7412849.743.67FalseNoneNoneFalseNoneFalse47158.54580
289426994774NoneV-1 Item No 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., complete with all lead Cum9129.839129.830.158FalseNoneNoneFalseNoneFalse1442.513140
289427094774NoneV-1 Item No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all lead Tonne111987.82111987.820.777FalseNoneNoneFalseNoneFalse87014.536140
289427194774None18-19 SR Item No 4.21Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., complete with all lead Rmtr38.9438.945.2FalseNoneNoneFalseNoneFalse202.4880
289427294774NoneData RateProviding throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., complete with all lead Rmtr86.1486.14156.0FalseNoneNoneFalseNoneFalse13437.840
289427394774NoneV-2 Item No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., complete with all lead Sqm1639.941639.94207.72FalseNoneNoneFalseNoneFalse340648.33680
289427494774NoneV-2 Item No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., complete with all lead Sqm8430.048430.041.8FalseNoneNoneFalseNoneFalse15174.0720
289427594774NoneV-2 Item No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., complete with all lead Kgs210.31210.3137.8FalseNoneNoneFalseNoneFalse7949.7180
289427694774NoneV-2 Item No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., complete with all lead Sqm5605.845605.841.68FalseNoneNoneFalseNoneFalse9417.81120
289427794774NoneV-2 Item No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., complete with all lead Sqm390.58390.58105.72FalseNoneNoneFalseNoneFalse41292.11760
289427894774NoneV-2 Item No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm216.58216.5831.084FalseNoneNoneFalseNoneFalse6732.172720
289427994774NoneV-2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all lead Sqm103.9103.931.084FalseNoneNoneFalseNoneFalse3229.62760
289428094774NoneV-2 Item No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., complete with all lead Sqm436.9436.9394.92FalseNoneNoneFalseNoneFalse172540.5480
289428194774NoneV-2 Item No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm158.98158.9831.084FalseNoneNoneFalseNoneFalse4941.734320
289428294774NoneV-2 Item No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm195.29195.29394.92FalseNoneNoneFalseNoneFalse77123.92680
289428394774NoneV-2 Item No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm62.662.63.48FalseNoneNoneFalseNoneFalse217.8480
289428494774NoneV-2 Item No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all lead Sqm143.96143.963.48FalseNoneNoneFalseNoneFalse500.98080
289428594774NoneV-5 Item No 10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all lead m514.52514.5260.0FalseNoneNoneFalseNoneFalse30871.20
289428694774NoneV-2 Item No 14.28.1.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines ---- etc., complete with all lead m109.09109.0915.0FalseNoneNoneFalseNoneFalse1636.350
289428794774NoneV-5 Item No T090DProviding and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc.50mm nominal bore pipes, From Sink ---- etc., complete with all lead m172.32172.3220.0FalseNoneNoneFalseNoneFalse3446.40
289428894774NoneV-5 Item No M010ESupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 - Internal piping ---- etc., complete with all lead m260.34260.34100.0FalseNoneNoneFalseNoneFalse26034.00
289428994774NoneV-5 Item No M010GSupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 - Internal piping ---- etc., complete with all lead m488.45488.4545.0FalseNoneNoneFalseNoneFalse21980.250
289429094774NoneV-2 Item No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete with all lead Each1512.441512.446.0FalseNoneNoneFalseNoneFalse9074.640
289429194774NoneV-2 Item No 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete with all lead Nos768.62768.626.0FalseNoneNoneFalseNoneFalse4611.720
289429294774NoneV-2 Item No 14.44Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting,of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. ---- etc., complete with all lead Each13914.4813914.486.0FalseNoneNoneFalseNoneFalse83486.880
289429394774NoneV-2 Item No 14.4.4Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. ---- etc., complete with all lead Each12892.9612892.962.0FalseNoneNoneFalseNoneFalse25785.920
289429494774NoneV-2 Item No 14.10.1.4Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., complete with all lead Nos5990.275990.271.0FalseNoneNoneFalseNoneFalse5990.270
289429594774NoneV-2 Item No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete,including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete with all lead Each6300.26300.28.0FalseNoneNoneFalseNoneFalse50401.60
289429694774NoneV-2 Item No 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps. ---- etc., complete with all lead Each3820.783820.786.0FalseNoneNoneFalseNoneFalse22924.680
289429794774NoneV-2 Item No 14.7.10Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: Stainless Steel AISI-304(18/8) Round basin 405x355 mm with single 15 mm C.P. brass pillar tap ---- etc., complete with all lead Each4361.294361.291.0FalseNoneNoneFalseNoneFalse4361.290
289429894774NoneV-2 Item No 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. ---- etc., complete with all lead Each1004.171004.1716.0FalseNoneNoneFalseNoneFalse16066.720
289429994774NoneV-2 Item No 14.28.2.1Providing and fixing P.V.C. waste pipe for sink or wash basin & closet including P.V.C. waste fittings complete - Flexible pipe - 32/40mm dia ---- etc., complete with all lead Each114.06114.0616.0FalseNoneNoneFalseNoneFalse1824.960
289430094774NoneV-2 Item No 14.16AProviding and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. ---- etc., complete with all lead Each337.2337.26.0FalseNoneNoneFalseNoneFalse2023.20
289430194774NoneV-2 Item No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., complete with all lead Each302.49302.4930.0FalseNoneNoneFalseNoneFalse9074.70
289430294774NoneV2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Internal work - 15 mm nominal dia Pipes ---- etc., complete with all lead m383.08383.0820.0FalseNoneNoneFalseNoneFalse7661.60
289430394774NoneV2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Internal work,shafts & terrace - 20 mm nominal dia Pipes ---- etc., complete with all lead m469.85469.8580.0FalseNoneNoneFalseNoneFalse37588.00
289430494774NoneV2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. Internal work,shafts & terrace - 25 mm nominal dia Pipes ---- etc., complete with all lead m591.35591.3530.0FalseNoneNoneFalseNoneFalse17740.50
289430594774NoneV2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.. Internal work,shafts & terrace - 32 mm nominal dia Pipes ---- etc., complete with all lead m690.51690.5150.0FalseNoneNoneFalseNoneFalse34525.50
289430694774NoneV2 Item No 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 25 mm dia ---- etc., complete with all lead Nos680.6680.66.0FalseNoneNoneFalseNoneFalse4083.60
289430794774NoneV2 Item No 13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 32 mm dia ---- etc., complete with all lead Nos741.35741.352.0FalseNoneNoneFalseNoneFalse1482.70
289430894774NoneV2 Item No 13.4.3Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm dia ---- etc., complete with all lead Nos870.27870.272.0FalseNoneNoneFalseNoneFalse1740.540
289430994774NoneV-2 Item No 13.2.1Providing and fixing brass bib cock of approved quality - 15 mm nominal bore ---- etc., complete with all lead Each354.55354.552.0FalseNoneNoneFalseNoneFalse709.10
289431094774NoneV-2 Item No 14.42Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2" BSP thread and shapes, weighing not less than 60 g. ---- etc., complete with all lead Each114.06114.062.0FalseNoneNoneFalseNoneFalse228.120
289431194774NonePWD Ele SR 2-23-24 Item No 1.2.1Concealed Conduit System - Supplying heavy gauge PVC conduit pipe 19/20dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary ---- etc., complete with all lead Mtr80.2280.22600.0FalseNoneNoneFalseNoneFalse48132.00
289431294774NonePWD Ele SR 2-23-24 Item No 1.2.2Concealed Conduit System - Supplying heavy gauge PVC conduit pipe 25dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary ---- etc., complete with all lead Mtr94.894.8500.0FalseNoneNoneFalseNoneFalse47400.00
289431394774NonePWD Ele SR 2-23-24 Item No 1.2.3Concealed Conduit System Supplying heavy gauge PVC conduit pipe 32dia 2.5mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary ---- etc., complete with all lead Mtr125.19125.1930.0FalseNoneNoneFalseNoneFalse3755.70
289431494774NonePWD Ele SR 2-23-24 Item No 1.3.1Groove Cutting in Wall - Supplying heavy gauge PVC conduit pipe 19/20dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete with all lead Mtr82.6582.65180.0FalseNoneNoneFalseNoneFalse14877.00
289431594774NonePWD Ele SR 2-23-24 Item No 1.3.2Groove Cutting in Wall - Supplying heavy gauge PVC conduit pipe 25dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete with all lead Mtr96.0296.02150.0FalseNoneNoneFalseNoneFalse14403.00
289431694774NonePWD Ele SR 2-23-24 Item No 1.3.3Groove Cutting in Wall - Supplying heavy gauge PVC conduit pipe 32dia 2.5 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. ---- etc., complete with all lead Mtr120.32120.3230.0FalseNoneNoneFalseNoneFalse3609.60
289431794774NonePWD Ele SR 2-23-24 Item No 1.12Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., complete with all lead Nos194.46194.4620.0FalseNoneNoneFalseNoneFalse3889.20
289431894774NonePWD Ele SR 2-23-24 Item No 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete with all lead Point326.94326.9435.0FalseNoneNoneFalseNoneFalse11442.90
289431994774NonePWD Ele SR 2-23-24 Item No 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point up to 3Mtr from tapping point to out let via switch - Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete with all lead Point460.64460.6430.0FalseNoneNoneFalseNoneFalse13819.20
289432094774NonePWD Ele SR 2-23-24 Item No 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short point up to 3Mtr from tapping point to out let via switch - Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete with all lead Point674.55674.5544.0FalseNoneNoneFalseNoneFalse29680.20
289432194774NonePWD Ele SR 2-23-24 Item No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 1.5 Sqmm ---- etc., complete with all lead Point31.631.6200.0FalseNoneNoneFalseNoneFalse6320.00
289432294774NonePWD Ele SR 2-23-24 Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. -2.5Sqmm ---- etc., complete with all lead Point51.0551.05675.0FalseNoneNoneFalseNoneFalse34458.750
289432394774NonePWD Ele SR 2-23-24 Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 4Sqmm ---- etc., complete with all lead Point76.5776.57530.0FalseNoneNoneFalseNoneFalse40582.10
289432494774NonePWD Ele SR 2-23-24 Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 6 Sqmm ---- etc., complete with all lead Point111.82111.8250.0FalseNoneNoneFalseNoneFalse5591.00
289432594774NoneVol. 6 PWD Item No 2.3.6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 10Sqmm ---- etc., complete with all lead Point202.97202.9760.0FalseNoneNoneFalseNoneFalse12178.20
289432694774NonePWD Ele SR 2-23-24 Item No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 1-2WAY ---- etc., complete with all lead Each167.73167.736.0FalseNoneNoneFalseNoneFalse1006.380
289432794774NonePWD Ele SR 2-23-24 Item No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 3WAY ---- etc., complete with all lead Each193.25193.252.0FalseNoneNoneFalseNoneFalse386.50
289432894774NonePWD Ele SR 2-23-24 Item No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 4WAY ---- etc., complete with all lead Each215.13215.132.0FalseNoneNoneFalseNoneFalse430.260
289432994774NonePWD Ele SR 2-23-24 Item No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 6WAY ---- etc., complete with all lead Each267.39267.3915.0FalseNoneNoneFalseNoneFalse4010.850
289433094774NonePWD Ele SR 2-23-24 Item No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall- 8WAY ---- etc., complete with all lead Each317.22317.2210.0FalseNoneNoneFalseNoneFalse3172.20
289433194774NonePWD Ele SR 2-23-24 Item No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall - 12WAY ---- etc., complete with all lead Each387.71387.7110.0FalseNoneNoneFalseNoneFalse3877.10
289433294774NonePWD Ele SR 2-23-24 Item No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2 module ---- etc., complete with all lead Each166.51166.516.0FalseNoneNoneFalseNoneFalse999.060
289433394774NonePWD Ele SR 2-23-24 Item No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 module ---- etc., complete with all lead Each195.68195.682.0FalseNoneNoneFalseNoneFalse391.360
289433494774NonePWD Ele SR 2-23-24 Item No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., complete with all lead Each212.7212.72.0FalseNoneNoneFalseNoneFalse425.40
289433594774NonePWD Ele SR 2-23-24 Item No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 6 Module ---- etc., complete with all lead Each284.4284.415.0FalseNoneNoneFalseNoneFalse4266.00
289433694774NonePWD Ele SR 2-23-24 Item No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. - 8 Module ---- etc., complete with all lead Each345.17345.1710.0FalseNoneNoneFalseNoneFalse3451.70
289433794774NonePWD Ele SR 2-23-24 Item No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. -12 Module ---- etc., complete with all lead Each418.1418.110.0FalseNoneNoneFalseNoneFalse4181.00
289433894774NonePWD Ele SR 2-23-24 Item No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -6Amps one way Switch ---- etc., complete with all lead Each123.97123.97133.0FalseNoneNoneFalseNoneFalse16488.010
289433994774NonePWD Ele SR 2-23-24 Item No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - 6Amps 3way socket ---- etc., complete with all lead Each207.83207.8324.0FalseNoneNoneFalseNoneFalse4987.920
289434094774NonePWD Ele SR 2-23-24 Item No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. - Stepped Fan Regulator Two Module ---- etc., complete with all lead Each433.9433.920.0FalseNoneNoneFalseNoneFalse8678.00
289434194774NonePWD Ele SR 2-23-24 Item No 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.- 32Amps DP switch ---- etc., complete with all lead Each396.22396.2225.0FalseNoneNoneFalseNoneFalse9905.50
289434294774NonePWD Ele SR 2-23-24 Item No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. -6/16Amps universal socket ---- etc., complete with all lead Each286.83286.8325.0FalseNoneNoneFalseNoneFalse7170.750
289434394774NonePWD Ele SR 2-23-24 Item No 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure double door - 12Way SP & N ---- etc., complete with all lead Each2830.672830.671.0FalseNoneNoneFalseNoneFalse2830.670
289434494774NonePWD Ele SR 2-23-24 Item No 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure double door - 4 Way TP & N ---- etc., complete with all lead Each4907.794907.792.0FalseNoneNoneFalseNoneFalse9815.580
289434594774NonePWD Ele SR 2-23-24 Item No 5.18.1Supplying and fixing of 6-32Amps SP miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ---- etc., complete with all lead Each504.39504.3934.0FalseNoneNoneFalseNoneFalse17149.260
289434694774NonePWD Ele SR 2-23-24 Item No 5.18.9Supplying and fixing of 50-63Amps TPN miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 ---- etc., complete with all lead Each3753.163753.162.0FalseNoneNoneFalseNoneFalse7506.320
289434794774NonePWD Ele SR 2-23-24 Item No 5.20.1Supplying, fixing and wiring 16A-25A 2 pole Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel boar ---- etc., complete with all lead Each5198.275198.271.0FalseNoneNoneFalseNoneFalse5198.270
289434894774NonePWD Ele SR 2-23-24 Item No 11.5.3Supply of round recess/surface mounted rolling type LED Down light with 18W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition ---- etc., complete with all lead Each1609.191609.1924.0FalseNoneNoneFalseNoneFalse38620.560
289434994774NonePWD Ele SR 2-23-24 Item No 11.3.2Supplying of 4feet - PVC Batten with integrated LED tube 20W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- etc., complete with all lead Each838.63838.6342.0FalseNoneNoneFalseNoneFalse35222.460
289435094774NonePWD Ele SR 2-23-24 Item No 11.11.3Supplying & fixing of retrofit type - LED bulb 7 W, 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- etc., complete with all lead Each181.09181.092.0FalseNoneNoneFalseNoneFalse362.180
289435194774NonePWD Ele SR 2-23-24 Item No 11.11.5Supplying & fixing of retrofit type - LED bulb 12W, 6500K with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. ---- etc., complete with all lead Each326.94326.948.0FalseNoneNoneFalseNoneFalse2615.520
289435294774NonePWD Ele SR 2-23-24 Item No 11.8.2Supply of 40w LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 40W System Power consumption. LED Efficiency greater than 130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. ---- etc., complete with all lead Nos4891.994891.992.0FalseNoneNoneFalseNoneFalse9783.980
289435394774NonePWD Ele SR 2-23-24 Item No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., complete with all lead Each1813.381813.385.0FalseNoneNoneFalseNoneFalse9066.90
289435494774NonePWD Ele SR 2-23-24 Item No 6.2.2Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 15" Sweep (450 mm) ---- etc., complete with all lead Each5403.675403.676.0FalseNoneNoneFalseNoneFalse32422.020
289435594774NonePWD Ele SR 2-23-24 Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.- 48" Sweep (1200mm) Regular model ---- etc., complete with all lead Each3626.753626.7520.0FalseNoneNoneFalseNoneFalse72535.00
289435694774NonePWD Ele SR 2-23-24 Item No 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete with all lead Each76.5776.5710.0FalseNoneNoneFalseNoneFalse765.70
289435794774NonePWD Ele SR 2-23-24 Item No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. - On wall / ceiling / Rafter / Girders ---- etc., complete with all lead Each148.28148.2866.0FalseNoneNoneFalseNoneFalse9786.480
289435894774NonePWD Ele SR 2-23-24 Item No 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete with all lead Each382.85382.8520.0FalseNoneNoneFalseNoneFalse7657.00
289435994774NonePWD Ele SR 2-23-24 Item No 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all lead Each859.29859.2911.0FalseNoneNoneFalseNoneFalse9452.190
289436094774NonePWD Ele SR 2-23-24 Item No 13.4.1Supplying and fixing telescopic M.S. single bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. ---- etc., complete with all lead Each1775.71775.72.0FalseNoneNoneFalseNoneFalse3551.40
289436194774NonePWD Ele SR 2-23-24 Item No 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete with all lead Each196.89196.892.0FalseNoneNoneFalseNoneFalse393.780
289436294774NonePWD Ele SR 2-23-24 Item No 5.17.3Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2.12 Way ---- etc., complete with all lead Each18873.9518873.951.0FalseNoneNoneFalseNoneFalse18873.950
289436394774NonePWD Ele SR 2-23-24 Item No 5.15.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA ---- etc., complete with all lead Each10315.110315.11.0FalseNoneNoneFalseNoneFalse10315.10
289436494774NonePWD Ele SR 2-23-24 Item No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN ---- etc., complete with all lead Each3699.683699.684.0FalseNoneNoneFalseNoneFalse14798.720
289436594774NoneLs Consultancy Charges For Architectural, Structural, & DPR Charges 1% ---- etc., complete with all lead Nos91809.091809.01.0FalseNoneNoneFalseNoneFalse91809.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17093897960000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17093897960001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17093897960001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submissionNone
17093898410000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17093898510000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17093898620000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17093898720000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17093898820000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17093898920000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17093899050000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17093899150000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17093899260000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17093899380000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17093899480000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17093899590000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of executionNone
17093899730000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17093899840000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17093899960000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17093900060000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17093900160000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17093900270000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17093900360000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17093900470000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2023-24.None
17093900590000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.55.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)RCC and PCC 134.00 Cum 2)Steel Reinforcement for RCC work 15.00 Tonnes 3)Cement concrete Block Masonry/Solid Block Masonry 835.00 Sqm,6)Plastering 2050.00 Sqm, 7)Painting 1560.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.3.50 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.2.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1Project Manager BE Civil with minimum experience of 15 years in the Construction of buildings 1 One. 2)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 One 3)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 1 OneCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates
NoneNoneNoneNoneKPWD Class-III and above Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 06 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Ongoing commitments and Bids submitted for the works certificate issued by the officer not lessthan the rank of Executive Engineer
NoneNoneNoneNoneClause ITT 3.2(a):The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs. 219.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.33.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Certificate issued by a Scheduled/Nationalised Bank
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Work done certificateTrueTechnical Bid
ESI, PF and GST Registration CertificatesTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsChitradurgaChitradurgaChitradurgaCHITRADURGAChitradurgaNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1709391280000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, HFWD, Arogya Soudha, 3rd Floor, 1st Cross Magadi Road
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone