createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709377851532
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee750.00
emd50620.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-03-2024 17:00:00
tenderQueryClose06-03-2024 17:30:00
technicalBidOpenNone
publishedDate04-03-2024 08:54:55
publishedByPostDMA_EE6_CC_HD
publishedByUserKPE11325 - ANANDKUMAR S ZALAKI
bidValidityPeriod90
noOfCalls3
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonAnandkumar S Zalaki
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08362213838
mobileNumber7676761667
tenderSupplierListNone
tenderSchedule
createdTs1709377851535
version21
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT1298/CALL-3
titleProviding basic facilities such as UGD, FIXING OF PAVERS , etc at SC/ST community area and shed construction at HDMC area in ward no 3 dharwad
descriptionProviding basic facilities such as UGD, FIXING OF PAVERS , etc at SC/ST community area and shed construction at HDMC area in ward no 3 dharwad
categoryWORKS
categoryTextWorks
ecv3000000.02
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2170
locationNameDMA City Corporation Hubballi-Dharawada
provisionalAmount3000000.0
groupOverheadTotal468973.81
fileNumber0216652
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17093778520001NoneNoneOther WorksProviding basic facilities such as UGD, FIXING OF PAVERS , etc at SC/ST community area and shed construction at HDMC area in ward no 3 dharwad2531026.21
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
288805894522None001Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. Sqm58.858.8261.25FalseNoneNoneFalseNoneFalse15361.50
288805994522None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Cum474.6474.639.19FalseNoneNoneFalseNoneFalse18599.5740
288806094522None003Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Cum76.6576.6510.34FalseNoneNoneFalseNoneFalse792.5610
288806194522None004Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Cum5466.35466.37.55FalseNoneNoneFalseNoneFalse41270.5650
288806294522None005Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 300 x 150 mm Kerb Stone Mtr444.15444.1544.5FalseNoneNoneFalseNoneFalse19764.6750
288806394522None006Wet Mix Macadam (plant mix method) Providing, laying speeding and compacting graded stone aggregate to wet mix Macadam specifications including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tipper to site , laying in uniform layers with paver / grader in sub- base course on well prepared surface and compacting with vibratory roller toachieve the desired density (.PWD SR 2021-22 Vol No.03 P.No.24 SI No. 4.27 MoRT&H spec.406A) Cum2513.72513.737.83FalseNoneNoneFalseNoneFalse95093.2710
288806494522None007Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications. Cum1202.251202.25378.25FalseNoneNoneFalseNoneFalse454751.06250
288806594522None008Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg114.45114.4510328.5FalseNoneNoneFalseNoneFalse1182096.8250
288806694522None009Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. Sqm583.8583.8457.05FalseNoneNoneFalseNoneFalse266825.790
288806794522None010Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm) Rmtr573.3573.317.0FalseNoneNoneFalseNoneFalse9746.10
288806894522None011Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) Rmtr550.2550.297.0FalseNoneNoneFalseNoneFalse53369.40
288806994522None012Providing and laying SurfaceMount Reinforcement to RDSO spect,without Arm rest and brick support with material specification of RCC M-30 Grade cone ie mix in accordance with IS 10269/Latest in gray cement by using vibro-compaction tecnique and with reinforcement as detailed in Govg speen.TMT reinforcement bars used as stirrups as per drawing stirrups of 10 No-4 mm dia bar @ 150 mm C/C and main reinforcement 4 nos-10 mm dia.Each seating plank(bottom) of bench bolted with leg by help of 12 mm dia x 65 mm length galvanised steel countersunk bolts wit EVA washer-backset planks fitted with half treaded carraige bolts and nuts of size 165mmx8 mm dia with EVA & steel washer-Plank dimension -1500 mm x440mm seat height from the ground 450mm, Distance between both legs , 340mm architect drawing and direction. The work includes all other incidental works required to complete the work in all repsects for smooth functioning of the equipment at all times in all respect for its intended use.The work required in fixing the requirement at all times in fixing the equipment on site as per the site condition. The cost includes cost of transportaion cost oflabour,HOM of machinery etc., required to complete the work. As per the direction of Engineer-in charge(SE Appoved) Nos15340.015340.04.0FalseNoneNoneFalseNoneFalse61360.00
288807094522None013Earth work excavation for pipeline trenches all kinds of soil by mechanical means above 600 mm trench .width as per drawing and technical specifications, including settings out , construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required, utilised the available excavated Earth locally for the work etc ., And all other apputenances complete in the following strata. Deapth exceeding 1.5 mm ,but not exceeding 3 mm(.PWD SE 2021-22 Vol No .01 P.No .10 SI No.1.17.2) Cum258.3258.3108.91FalseNoneNoneFalseNoneFalse28131.4530
288807194522None014Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS "using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick,except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting,pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering,engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame .PWD SR 2021-22WS & UGD 2021 -22 P.No.188SI No.13.1 T300A='LBD Entry FINALB105:H105 Nos29322.329322.33.0FalseNoneNoneFalseNoneFalse87966.90
288807294522None015Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber.Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick,except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting,pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering,engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H:Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame .PWD SR 2021-22WS & UGD 2021 -22 P.No.188SI No.13.2 T300B) Nos29900.8529900.851.0FalseNoneNoneFalseNoneFalse29900.850
288807394522None016supplying lowering laying jointing testing and commissioning of following daimeters glazed stone ware pipes, confirming to IS 651:1992,(with 5th revision) in all respects jointing with EPDM rubber ring (seals according to EN 681 & ASPM 425) The rubber seals joitns pipe will have. groves in interior of socket and exterior of the spigot .The rubber gasket shal be prefixed at the factory by the manufacturer rigidly with approved glue to have leak. Proof joint including conveying of pipe to work site and rolling and lowering into trenches, laying true to line, level and perfect linking at joints testing and commissioning including loading and unloading at both destination and cuts of pipes wherever necessary jointing of GST pipes and specials , with rubber gasket confirming to EN 681and ASTMC-425 including cleaning the socket and spigot with soap solution and applying talcum powder for detecting crack, then applying glue etc.and giving including the cost of soap solution, talcum powder and glue etc.and giving necessary hydraulic test to the required pressure of water head with all lead and lifts including costing of jointing materials and necessary survey works for laying of sewers etc .and disposal of debris as directed etc , complete.( Contractor will make Rubber ring gasket joints.230mm dai (. PWD SR 2021-22 P.No 184 SI No.2.4T030D WS & UGD SR 2021-22 Rmtr841.05841.0578.0FalseNoneNoneFalseNoneFalse65601.90
288807494522None017r Refilling available Earth around trenches/ pipelines, cables in layers not exceeding 10 cm in depth , compacting each deposited layer by ramming after watching with a lead upto 50 m ,and lift upto 1.5 m including cost of all labour complete as per specifications.(PWD SR 2021-22 vol No No 01 P.No .7SI No.1.10) Cum128.1128.175.01FalseNoneNoneFalseNoneFalse9608.7810
288807594522None018Mains Pipe. Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 1.1.1) 19/20mm dia 2mm thick PWD,Elct, SR 2021-22 Page No. 1 IItem code 1.1.1 Mtr68.068.0175.0FalseNoneNoneFalseNoneFalse11900.00
288807694522None019Points Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each Point251.0251.01.0FalseNoneNoneFalseNoneFalse251.00
288807794522None020Points Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. 2.2.2) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box PWD,Elct, SR2021-22 Page No. 3 IItem code 2.2.2 Point361.0361.021.0FalseNoneNoneFalseNoneFalse7581.00
288807894522None021 Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm Point542.0542.010.0FalseNoneNoneFalseNoneFalse5420.00
288807994522None022 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Mtr26.026.090.0FalseNoneNoneFalseNoneFalse2340.00
288808094522None023 Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. Mtr40.040.0175.0FalseNoneNoneFalseNoneFalse7000.00
288808194522None024PVC modular box:: Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. Nos277.0277.01.0FalseNoneNoneFalseNoneFalse277.00
288808294522None025 Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including Nos225.0225.04.0FalseNoneNoneFalseNoneFalse900.00
288808394522None026modular Switch Plate Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.5)10 -12 Module Nos363.0363.01.0FalseNoneNoneFalseNoneFalse363.00
288808494522None027modular Switch Plate Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3.5.6)16-18 Module PWD,Elct, SR2021-22 Page No. 5 IItem code3.5.6 Nos403.0403.04.0FalseNoneNoneFalseNoneFalse1612.00
288808594522None028Modular switch Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.1)6Amps one way. PWD,Elct, SR2021-22 Page No.5 IItem code 3.6.1 Nos88.088.037.0FalseNoneNoneFalseNoneFalse3256.00
288808694522None029Modular socket Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.3)6Amps 3way socket PWD,Elct, SR2021-22 Page No. 5 IItem code 3.6.3 Nos162.0162.05.0FalseNoneNoneFalseNoneFalse810.00
288808794522None030Stepped Fan Regulator. Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 3.6.4)Stepped Fan Regulator Two Module PWD,Elct, SR2021-22 Page No. 5 IItem code 3.6.4 Nos313.0313.09.0FalseNoneNoneFalseNoneFalse2817.00
288808894522None031Batten Holder Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 3.14.6) 6 Amps lamp holder PWD,Elct, SR2021-22 Page No. 6 IItem code 3.14.6 Nos63.063.023.0FalseNoneNoneFalseNoneFalse1449.00
288808994522None032Celling Rose Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 3.14.5) 6Amps Bakelite ceiling rose PWD,Elct, SR2021-22 Page No.6 IItem code 3.14.5 Nos63.063.09.0FalseNoneNoneFalseNoneFalse567.00
288809094522None033LED Tube Fitting Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2) LED light fitting 1 4 20/22 W PWD Elct, SR 2021-22 Page No.34 I11.3.2Nos740.0740.020.0FalseNoneNoneFalseNoneFalse14800.00
288809194522None034LED Fitting fixing Charges Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. 13.7.1) On wall / ceiling / Rafter / Girders PWD,Elct, SR2021-22 Page No.45 IItem code 13.7.1 Nos119.0119.020.0FalseNoneNoneFalseNoneFalse2380.00
288809294522None035 volts, 50 cycles. Single phase AC supply conforming to ISS-374-19Nos2085.02085.09.0FalseNoneNoneFalseNoneFalse18765.00
288809394522None036Fan Fixing Charges Fixing a ceiling / wall mounting fan of all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. PageNos281.0281.09.0FalseNoneNoneFalseNoneFalse2529.00
288809494522None037MCB Switches. Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5.17.4) 6-32 Amps DP PWD,Elct, SR2021-22 Page No. 13 IItem code5.17.4 Nos1103.01103.02.0FalseNoneNoneFalseNoneFalse2206.00
288809594522None038MCB distribution boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. I - Single Door 5.18.1)4 Way SP & N PWD,Elct, SR2021-22 Page No. 13 IItem code 5.18.1 Nos1104.01104.01.0FalseNoneNoneFalseNoneFalse1104.00
288809694522None039XXXIV)Transformer grounding e)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs item no. XXXIV.a) page no.3 Hescom SR 2021-22 (Material Charges) Each725.0725.01.0FalseNoneNoneFalseNoneFalse725.00
288809794522None040Transformer grounding e)GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolts nuts, GI Strips and washers complete Minimum Weight of GI Pipe: 7.3 Kgs item no. XXXIV.a) page no.3 Hescom SR 2021-22 (Material Charges) Each1733.01733.01.0FalseNoneNoneFalseNoneFalse1733.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17093778520000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17093778520000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by any State Government/Government of India/Union TerritoryNone
17093778520000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his-her status as Scheduled Caste-Scheduled Tribe/other reserved category as prescribed in the tender documentNone
17093778520000NoneNoneELIGIBILITYMinimum financial turnover (civil engineering construction works) not less than One times the annual payments from this contract as per KW-2None
17093778520000NoneNoneELIGIBILITYSatisfactorily completed (at least 50% of the contract value), as prime contractor, at least one similar work is to be completed of value not less than Rs. 12.66 lakhs -Usually not less than 50% estimated value of contractNone
17093778520000NoneNoneELIGIBILITYTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrification works and should have executed similar electrical works totallng (not less than 50% of electrical works) n any one yearNone
17093778520000NoneNoneELIGIBILITYThe Payment for the work will be made based on availability of funds and according to Queue systemNone
17093778520000NoneNoneELIGIBILITYTotal value of civl engineering works executed and payments received in the last five years (year-wise)None
17093778520000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17093778520000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17093778520000NoneNoneELIGIBILITYBanker Details for referenceNone
17093778520000NoneNoneELIGIBILITYConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNone
17093778520000NoneNoneELIGIBILITYReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNone
17093778520000NoneNoneELIGIBILITYQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNone
17093778520000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17093778520000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders end.None
17093778520000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17093778520000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17093778520000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17093778520000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the submitted tender bid shall be liable to be rejectedNone
17093778520000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt, orders as may be modified from time to timeNone
17093778520000NoneNoneELIGIBILITYAs per Karnataka state Government order No.LD/300/LET/2006 Banglore Dated 01-01-2007 and Government Letter No PW/134/BMS/2007 Dated 27-7-2007, a sum amounting to 1% of the bill amount will be deducted towards construction Labour welfare fundNone
17093778520000NoneNoneELIGIBILITYThe tenderer shall scan original Workdone certificates/Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid openingNone
17093778520000NoneNoneELIGIBILITYThe Employer reserves the right to reject any or all Tenders without assigning any reason or what so everNone
17093778520000NoneNoneELIGIBILITYThe earnest money deposit will be forfeited if the documents submitted by the tenderer found to be misleading/forged or fake/Taken backNone
17093778520000NoneNoneELIGIBILITYThe contractors shall collect necessary samples as required & all relevant requisite tests to be got done by the registered institution or firms with consultants with the Third PartyNone
17093778520000NoneNoneELIGIBILITYThe Department is not responsible for any delay caused in accessing the e-procurement portalNone
17093778520000NoneNoneELIGIBILITYTender validity for valid bid is 90 daysNone
17093778520000NoneNoneELIGIBILITYConditional LOC (Line of Credit) are not AcceptableNone
17093778520000NoneNoneELIGIBILITYThe Tenders/ Bids are invited as per Standard tender Bid Document KW-2: The contractor shall attach all the requisite documents as required in the standard bid document. The Bidders shall abide as per the detailed instructions and conditions contained in standard bid document KW-2None
17093778520000NoneNoneELIGIBILITYFor unbalanced Tender if the rate quoted by bidder is less than the estimated amount, the additional security for difference in amount should be submitted. in the form of depositNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Financial Turnover Certificate From 2018-19 to 2022-23 as per kw-2 With UDIN NumberTrueTechnical Bid
Valid Contractor License Certificate issued by competent authorityTrueTechnical Bid
Workdone certificate-50 percent of Similar nature of work done certificate of amount put to tender as per kw-2TrueTechnical Bid
Line of Credit 30 percent of amount put to tender as per kw-2TrueTechnical Bid
GST CertificateTrueTechnical Bid
Pan CardTrueTechnical Bid
Agreed to Terms and conditions as per kw-2TrueTechnical Bid
Conditional LOC- Line of Credit are not AcceptableTrueTechnical Bid
Address proof and Contact number of a Contractor or Contact personTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone