createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709470098725
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1580.00
emd73290.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose11-03-2024 16:00:00
tenderQueryClose06-03-2024 11:00:00
technicalBidOpen12-03-2024 16:15:00
publishedDate03-03-2024 18:35:23
publishedByPostRDPR_EE_DIV_KPL
publishedByUserKPE15445 - H SATHYAPPA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonEXECUTIVE ENGINEER PRE DIVISION KOPPAL
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08539220577
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1709470098771
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2023-24/WT/WORK_INDENT5004
titleProviding and Fixing of RO Plant and Materails and Essential Needs to Chikkajantakal, Yaradona, Chellur, Hulihyder, Kanakagiri, Siddapur, Kanakagiri, Sriramnagar, Heroor,Marali,Yaradona, Chellur Village of Kankagiri Taluka Package No.10 (15 Villages)
descriptionProviding and Fixing of RO Plant and Materails and Essential Needs to Chikkajantakal, Yaradona, Chellur, Hulihyder, Kanakagiri, Siddapur, Kanakagiri, Sriramnagar, Heroor,Marali,Yaradona, Chellur Village of Kankagiri Taluka Package No.10 (15 Villages)
categoryWORKS
categoryTextWorks
ecv6286837.42
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location948
locationNameRDPR Division Office Koppal
provisionalAmount7329000.0
groupOverheadTotalNone
fileNumberEE/PRED/KPL/KKRDB/KNK/PACKAGE/10
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17094700990000NoneNoneWater /sewage treatment tanksConstruction of Computer Room Repairs of Building and materails Supply and Solar Supply and Installation at School at Chikkajanatakal Village951068.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289712294978None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.8574.62FalseNoneNoneFalseNoneFalse57744.6870
289712394978None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm91.3591.35292.86FalseNoneNoneFalseNoneFalse26752.7610
289712494978None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.454.56FalseNoneNoneFalseNoneFalse2749.8240
289712594978None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates Cum5947.25947.28.18FalseNoneNoneFalseNoneFalse48648.0960
289712694978None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2560.56FalseNoneNoneFalseNoneFalse72808.260
289712794978NoneBasic rateComputer Equipments : DUGONG Intel Core i3 12100 8 GB Windows 11 Professional DUGONGR BH 23 Speciations as mentioned in EstimateEach58000.058000.05.0FalseNoneNoneFalseNoneFalse290000.00
289712894978NoneBasic RateCRN Craft Non Revolving and Non Tilting Chair with Armest CRN Craft Specifications Chair Type Non Revolving and Non Tilting chair without armestEach1500.01500.012.0FalseNoneNoneFalseNoneFalse18000.00
289712994978NoneBasic RateUnbranded Computer Table Consists of Only Printer Table NAEach1500.01500.010.0FalseNoneNoneFalseNoneFalse15000.00
289713094978None11.58Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerin- charge. (Made of G.I. wire of dia 4 mm)Sqm843.15843.1516.0FalseNoneNoneFalseNoneFalse13490.40
289713194978None11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.25 x 25 x 5 angularKg142.8142.886.4FalseNoneNoneFalseNoneFalse12337.920
289713294978NoneBasic RateWays to charge Solar Power Pack AC Charging Cord ,Solar Panel Types Power Pack 500 Solar Chargern66 hrs (4.5W integrated solar panel) Govening Standards BIS Certification (For Solar photo voltaics, system, device and components including batteries shall have under complusory registration scheme of BIS as applicable)Warranty 1 yearEach59001.059001.06.0FalseNoneNoneFalseNoneFalse354006.00
289713394978None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.055.0FalseNoneNoneFalseNoneFalse3795.00
289713494978None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.08.0FalseNoneNoneFalseNoneFalse848.00
289713594978None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.08.0FalseNoneNoneFalseNoneFalse2280.00
289713694978None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.08.0FalseNoneNoneFalseNoneFalse3152.00
289713794978None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.08.0FalseNoneNoneFalseNoneFalse4440.00
289713894978None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
289713994978None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.018.0FalseNoneNoneFalseNoneFalse2646.00
289714094978None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
289714194978None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
289714294978None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.PipeNo978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
289714394978None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.055.0FalseNoneNoneFalseNoneFalse1430.00
289714494978None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.055.0FalseNoneNoneFalseNoneFalse2310.00
289714594978None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.055.0FalseNoneNoneFalseNoneFalse3465.00
289714694978None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
17094700990000NoneNoneWater /sewage treatment tanksSupplying of Library Books Sports Items Repairs of Building Supplying of Projectos Intergrated LED Display Green and Soft Boards Supply at GHPS School at Yaradona Village383900.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289714794979NoneBasic RateSupplying of Materails Mentioned in Estimate of 25 VarietiesNo170650.0170650.01.0FalseNoneNoneFalseNoneFalse170650.00
289714894979NoneBasic RateUnbranded 1800 mm 900 mm 730 mm Warranty periods 1 Year Design / Shape Rectangular Under structure of main tableWith Aluminum anodized access flap (for electrical provision) Table top material :MDF and venner with PU finish having scratch resistance of 2H Gable end material :MDF and venner with PU finish having scratch resistance of 2H Modesty panel material Length of table top 20 mm 3800 mm Depth of table top10 mm 900 mm Height of table top 10 mm :730 mm Dimension of leg 2 mm:NA Thickness of table top 2 mm:36 mmEach18525.018525.02.0FalseNoneNoneFalseNoneFalse37050.00
289714994979NoneBasic RateUnbranded Projector ScreenEach16550.016550.02.0FalseNoneNoneFalseNoneFalse33100.00
289715094979NoneBasic RateEPSON Standard Throw (0.91 to 2.5) Multimedia Projector (MMP) With 1280 x 800 (WXGA) Resolution EPSONREach47550.047550.02.0FalseNoneNoneFalseNoneFalse95100.00
289715194979NoneBasic RateWriting Board Mounting type Wall mounts Frame (All round framing) With Writing board placed on Core materialEach3000.03000.016.0FalseNoneNoneFalseNoneFalse48000.00
17094700990000NoneNoneWater /sewage treatment tanksSupplying of Library Books Sports Items Repairs of Building Supplying of Projectos Intergrated LED Display Green and Soft Boards Supply at GHPS School at Chellur Village445295.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289715294980NoneBasic RateSupplying of Materails Mentioned in Estimate of 25 VarietiesNo179420.0179420.01.0FalseNoneNoneFalseNoneFalse179420.00
289715394980NoneMARKET RATEUnbranded 1800 mm 900 mm 730 mm Warranty periods 1 Year Design / Shape Rectangular Under structure of main tableWith Aluminum anodized access flap (for electrical provision) Table top material :MDF and venner with PU finish having scratch resistance of 2H Gable end material :MDF and venner with PU finish having scratch resistance of 2H Modesty panel material Length of table top 20 mm 3800 mm Depth of table top10 mm 900 mm Height of table top 10 mm :730 mm Dimension of leg 2 mm:NA Thickness of table top 2 mm:36 mmEach18525.018525.03.0FalseNoneNoneFalseNoneFalse55575.00
289715494980NoneBasic RateUnbranded Projector ScreenEach16550.016550.03.0FalseNoneNoneFalseNoneFalse49650.00
289715594980NoneELECTRICAL EPSON Standard Throw (0.91 to 2.5) Multimedia Projector (MMP) With 1280 x 800 (WXGA) Resolution EPSONREach47550.047550.03.0FalseNoneNoneFalseNoneFalse142650.00
289715694980NoneBasic RateWriting Board Mounting type Wall mounts Frame (All round framing) With Writing board placed on Core materialEach3000.03000.06.0FalseNoneNoneFalseNoneFalse18000.00
17094700990000NoneNoneWater /sewage treatment tanksProviding and Fixing of RO Plant at GHPS at Chikkajantakal Village211592.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289715794981NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
289715894981None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.240.0FalseNoneNoneFalseNoneFalse20328.00
289715994981None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289716094981None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4540.0FalseNoneNoneFalseNoneFalse7938.00
17094700990000NoneNoneWater /sewage treatment tanksProviding and Fixing of RO Plant at GHPS School at Hulihyder Village211592.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289716194982NoneBasic rateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
289716294982None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& otherNo508.2508.240.0FalseNoneNoneFalseNoneFalse20328.00
289716394982None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289716494982None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Rmtr198.45198.4540.0FalseNoneNoneFalseNoneFalse7938.00
17094700990000NoneNoneWater /sewage treatment tanksProviding and Fixing of RO Plant at GHPS School at Kanakagiri Village211592.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289716594983NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
289716694983None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredNo508.2508.240.0FalseNoneNoneFalseNoneFalse20328.00
289716794983None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289716894983None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Rmtr198.45198.4540.0FalseNoneNoneFalseNoneFalse7938.00
17094700990000NoneNoneWater /sewage treatment tanksProviding and Fixing of RO Plant at GHPS School at Navali Village211592.4
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289716994984NoneBasic rateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
289717094984None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.240.0FalseNoneNoneFalseNoneFalse20328.00
289717194984None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289717294984None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Rmtr198.45198.4540.0FalseNoneNoneFalseNoneFalse7938.00
17094700990000NoneNoneWater /sewage treatment tanksConstruction of Building at GHPS School at Siddapur Village337120.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289717394985None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.110.8FalseNoneNoneFalseNoneFalse2744.280
289717494985None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.22.88FalseNoneNoneFalseNoneFalse17127.9360
289717594985None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.92.4FalseNoneNoneFalseNoneFalse16677.360
289717694985None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.251.92FalseNoneNoneFalseNoneFalse12509.280
289717794985None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.88FalseNoneNoneFalseNoneFalse19320.3360
289717894985None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.39.6FalseNoneNoneFalseNoneFalse2681.280
289717994985None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.354.35FalseNoneNoneFalseNoneFalse28715.87250
289718094985None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.811.1FalseNoneNoneFalseNoneFalse4356.8910
289718194985None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.682.33FalseNoneNoneFalseNoneFalse7690.58440
289718294985None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.850.44FalseNoneNoneFalseNoneFalse41329.1340
289718394985None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5510.13FalseNoneNoneFalseNoneFalse87336.30150
289718494985None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.15101.64FalseNoneNoneFalseNoneFalse34471.2060
289718594985None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.9101.64FalseNoneNoneFalseNoneFalse16862.0760
289718694985None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.11FalseNoneNoneFalseNoneFalse14345.3310
289718794985None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.23.96FalseNoneNoneFalseNoneFalse30952.1520
17094700990000NoneNoneWater /sewage treatment tanksConstruction of Building at GHPS School at Kanakagiri Village337120.02
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289718894986None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.110.8FalseNoneNoneFalseNoneFalse2744.280
289718994986None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.22.88FalseNoneNoneFalseNoneFalse17127.9360
289719094986None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.92.4FalseNoneNoneFalseNoneFalse16677.360
289719194986None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.251.92FalseNoneNoneFalseNoneFalse12509.280
289719294986None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.88FalseNoneNoneFalseNoneFalse19320.3360
289719394986None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.39.6FalseNoneNoneFalseNoneFalse2681.280
289719494986None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.354.35FalseNoneNoneFalseNoneFalse28715.87250
289719594986None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.811.1FalseNoneNoneFalseNoneFalse4356.8910
289719694986None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.682.33FalseNoneNoneFalseNoneFalse7690.58440
289719794986None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.850.44FalseNoneNoneFalseNoneFalse41329.1340
289719894986None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5510.13FalseNoneNoneFalseNoneFalse87336.30150
289719994986None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.15101.64FalseNoneNoneFalseNoneFalse34471.2060
289720094986None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.9101.64FalseNoneNoneFalseNoneFalse16862.0760
289720194986None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.11FalseNoneNoneFalseNoneFalse14345.3310
289720294986None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.23.96FalseNoneNoneFalseNoneFalse30952.1520
17094700990000NoneNoneWater /sewage treatment tanksConstruction of Building at GHPS School at Navali Village337159.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289720394987None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.110.8FalseNoneNoneFalseNoneFalse2744.280
289720494987None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.22.88FalseNoneNoneFalseNoneFalse17127.9360
289720594987None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.92.4FalseNoneNoneFalseNoneFalse16677.360
289720694987None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.251.92FalseNoneNoneFalseNoneFalse12509.280
289720794987None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.452.88FalseNoneNoneFalseNoneFalse19320.3360
289720894987None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.39.6FalseNoneNoneFalseNoneFalse2681.280
289720994987None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.354.35FalseNoneNoneFalseNoneFalse28715.87250
289721094987None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.811.11FalseNoneNoneFalseNoneFalse4396.49910
289721194987None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.682.33FalseNoneNoneFalseNoneFalse7690.58440
289721294987None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.850.44FalseNoneNoneFalseNoneFalse41329.1340
289721394987None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5510.13FalseNoneNoneFalseNoneFalse87336.30150
289721494987None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.15101.64FalseNoneNoneFalseNoneFalse34471.2060
289721594987None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.9101.64FalseNoneNoneFalseNoneFalse16862.0760
289721694987None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.11FalseNoneNoneFalseNoneFalse14345.3310
289721794987None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.23.96FalseNoneNoneFalseNoneFalse30952.1520
17094700990000NoneNoneWater /sewage treatment tanksSupplying of Toilet Cleaning Machine and Repairs of Electrification at GHPS School at Sriramnagar Village33699.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289721894988NoneBasic RateStainless Steel Top Sanitary Napkin Incrinerator Machine Burning Ability 500 Kg TimeNo20000.020000.01.0FalseNoneNoneFalseNoneFalse20000.00
289721994988None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
289722094988None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.03.0FalseNoneNoneFalseNoneFalse855.00
289722194988None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.03.0FalseNoneNoneFalseNoneFalse1182.00
289722294988None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.03.0FalseNoneNoneFalseNoneFalse1665.00
289722394988None3.8pplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwSqm0.410.41500.0FalseNoneNoneFalseNoneFalse205.00
289722494988None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 Way No147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
289722594988None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modelNos1900.01900.03.0FalseNoneNoneFalseNoneFalse5700.00
289722694988None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.Nos361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
289722794988None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2Sqm26.026.018.0FalseNoneNoneFalseNoneFalse468.00
289722894988None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmSqm42.042.018.0FalseNoneNoneFalseNoneFalse756.00
289722994988None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specifiedSqm63.063.018.0FalseNoneNoneFalseNoneFalse1134.00
17094700990000NoneNoneWater /sewage treatment tanksRepairs of Electrification at Heroor Village18301.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289723094989None1.1.1SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.Mtr69.069.030.0FalseNoneNoneFalseNoneFalse2070.00
289723194989None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
289723294989None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
289723394989None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
289723494989None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
289723594989None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
289723694989None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
289723794989None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
289723894989None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
289723994989None12.60.1Supplying&FixingChemicalearthlingforgrounding.Conduits,ICcut-outs&otherequipmentsbackfillcompoundwhichisnon-corrosive,thermallyconductive,potentialtopermissiblelimits,superiorFaultconductioncapacity,nontoxic,weatherresistance&capable of achieving ohmic value less than one ohmUsing 4ft. Copper bonded rod with backfill compoundNo4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
289724094989None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.024.0FalseNoneNoneFalseNoneFalse624.00
289724194989None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.024.0FalseNoneNoneFalseNoneFalse1008.00
289724294989None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.024.0FalseNoneNoneFalseNoneFalse1512.00
17094700990000NoneNoneWater /sewage treatment tanksRepairs of Room and Supplying and Fixing of RO Plant at GHPS School at RMSA Marali School380753.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289724394990None15.2Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2 l/per m2, having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 l/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm773.85773.8572.0FalseNoneNoneFalseNoneFalse55717.20
289724494990None8.72.1Finishing walls with water proofing cement paint of required shade :Old work (one coats applied @ 2.20 kg/10 m²) over priming coat of primer applied @ 0.80 litrs/10 m² complete including cost of Priming coat including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm91.3591.35251.2FalseNoneNoneFalseNoneFalse22947.120
289724594990None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.444.8FalseNoneNoneFalseNoneFalse2257.920
289724694990None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.24.8FalseNoneNoneFalseNoneFalse28546.560
289724794990None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm)Sqm1202.251202.2548.0FalseNoneNoneFalseNoneFalse57708.00
289724894990NoneBasic rateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
289724994990None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.No508.2508.240.0FalseNoneNoneFalseNoneFalse20328.00
289725094990None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289725194990None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Rmtr198.45198.4550.0FalseNoneNoneFalseNoneFalse9922.50
17094700990000NoneNoneWater /sewage treatment tanksProviding and Fixing of RO Plant Construction of Room Repairs of Room and Electrification and Toilet Cleaning Machine at GHPS School at Yaradona Village1804661.82
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289725294991None1.4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Cum254.1254.141.513FalseNoneNoneFalseNoneFalse10548.45330
289725394991None2.1.1Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates work as per technical specificationsCum5947.25947.212.72FalseNoneNoneFalseNoneFalse75648.3840
289725494991None5.2Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6948.96948.911.31FalseNoneNoneFalseNoneFalse78592.0590
289725594991None5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sandCum6515.256515.258.11FalseNoneNoneFalseNoneFalse52838.67750
289725694991None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.4512.3FalseNoneNoneFalseNoneFalse82513.9350
289725794991None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.345.9FalseNoneNoneFalseNoneFalse12819.870
289725894991None2.2.1Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6601.356601.3526.33FalseNoneNoneFalseNoneFalse173813.54550
289725994991None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm330.07330.071.73FalseNoneNoneFalseNoneFalse571.02110
289726094991None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm660.14660.142.73FalseNoneNoneFalseNoneFalse1802.18220
289726194991None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3960.813960.815.76FalseNoneNoneFalseNoneFalse22814.26560
289726294991None2.5.1Providing and removing centring shuttering propping etc and removal of form work for foundation appendix I percentage on finished rate of concrete per cumSqm3300.683300.6813.1FalseNoneNoneFalseNoneFalse43238.9080
289726394991None2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Tonne93929.8593929.852.75FalseNoneNoneFalseNoneFalse258307.08750
289726494991None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8621.558621.5519.64FalseNoneNoneFalseNoneFalse169327.2420
289726594991None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Sqm192.15192.15177.66FalseNoneNoneFalseNoneFalse34137.3690
289726694991None8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerin-charge.Sqm339.15339.1584.78FalseNoneNoneFalseNoneFalse28753.1370
289726794991None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm279.3279.3115.38FalseNoneNoneFalseNoneFalse32225.6340
289726894991None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm165.9165.984.78FalseNoneNoneFalseNoneFalse14065.0020
289726994991None8.29Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm297.15297.15115.38FalseNoneNoneFalseNoneFalse34285.1670
289727094991None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2557.8FalseNoneNoneFalseNoneFalse69490.050
289727194991None9.34Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specificationsSqm1622.251622.2518.7FalseNoneNoneFalseNoneFalse30336.0750
289727294991None12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. Cum130412.1130412.10.24FalseNoneNoneFalseNoneFalse31298.9040
289727394991None12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7816.27816.28.28FalseNoneNoneFalseNoneFalse64718.1360
289727494991None8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeNo4.24.27000.0FalseNoneNoneFalseNoneFalse29400.00
289727594991None88.84Providing Wall black in 12 mm thick with CM 1:3 and applied with primer and two coats of acyrlic emulsion black paint including finishing etc completeSqm498.75498.753.6FalseNoneNoneFalseNoneFalse1795.50
289727694991None12.80Providing and Fixing door latch with necessary screws etc completeSqm299.25299.253.6FalseNoneNoneFalseNoneFalse1077.30
289727794991None20.27.3Providing and Fixing bright finished brass flush bolts with necessary brass screws etc cpmpleteEach172.2172.222.0FalseNoneNoneFalseNoneFalse3788.40
289727894991None1.1.1Electrification:Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.040.0FalseNoneNoneFalseNoneFalse2760.00
289727994991None1.4.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNos106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
289728094991None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switch boxNos285.0285.04.0FalseNoneNoneFalseNoneFalse1140.00
289728194991None2.2.3Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
289728294991None2.2.3Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
289728394991None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws.Sqm0.410.411500.0FalseNoneNoneFalseNoneFalse615.00
289728494991None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayNos147.0147.016.0FalseNoneNoneFalseNoneFalse2352.00
289728594991None12.60Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compoundNos4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
289728694991None6.3Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing systemNos1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
289728794991None11.14.2Supplying and fixing of slim box fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube 1 x 4' Tube light fittingNos361.0361.04.0FalseNoneNoneFalseNoneFalse1444.00
289728894991None13.1.1Supplying and Fixing of.mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 25mm dia G.I.PipeNos978.0978.01.0FalseNoneNoneFalseNoneFalse978.00
289728994991NoneP No 23Pre - Paid Energy Meter Single Phase, 5-30 Amps, 1.0 Accuracy Class with Key Pad Technology consumer interface unit along with pillfer proof boxNo7170.07170.01.0FalseNoneNoneFalseNoneFalse7170.00
289729094991NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmMtr26.026.040.0FalseNoneNoneFalseNoneFalse1040.00
289729194991NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mmMtr42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
289729294991NoneP No 6Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:20104 mm2Mtr63.063.040.0FalseNoneNoneFalseNoneFalse2520.00
289729394991NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316No159000.0159000.01.0FalseNoneNoneFalseNoneFalse159000.00
289729494991None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Nos508.2508.238.0FalseNoneNoneFalseNoneFalse19311.60
289729594991None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289729694991None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0, 63mm diaRmtr198.45198.4538.0FalseNoneNoneFalseNoneFalse7541.10
289729794991None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign atter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm165.9165.9144.0FalseNoneNoneFalseNoneFalse23889.60
289729894991None19.22Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-chargeCum50.450.481.2FalseNoneNoneFalseNoneFalse4092.480
289729994991None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.25.68FalseNoneNoneFalseNoneFalse33780.0960
289730094991None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grou ting the joints with white cement and matching pigments etc., complete. (Size of Tile 600x600 mm) Sqm1202.251202.2586.32FalseNoneNoneFalseNoneFalse103778.220
289730194991NoneBasic RateStainless Steel Top Loading Sanitary Napkin Incinerator Machine Burning Ability 500 kg TimeNo24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
289730294991None1.1.1Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc 75 x 75 x 65 mmNo106.0106.04.0FalseNoneNoneFalseNoneFalse424.00
289730394991None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch boxNo285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
289730494991None2.2.1Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNo394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
289730594991None2.2.2Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNo555.0555.02.0FalseNoneNoneFalseNoneFalse1110.00
289730694991None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screwsSqm0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
289730794991None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 6A 3/5 WayEach147.0147.05.0FalseNoneNoneFalseNoneFalse735.00
289730894991None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep (1200 mm) Regular modeNo1900.01900.02.0FalseNoneNoneFalseNoneFalse3800.00
289730994991None11.13Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube.No361.0361.02.0FalseNoneNoneFalseNoneFalse722.00
289731094991None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mmm26.026.030.0FalseNoneNoneFalseNoneFalse780.00
289731194991None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 mm2m42.042.030.0FalseNoneNoneFalseNoneFalse1260.00
289731294991None2.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2m63.063.030.0FalseNoneNoneFalseNoneFalse1890.00
17094700990000NoneNoneWater /sewage treatment tanksRepairs of Room Building and Providing Water Supply Supply of Toilet Cleaning Machine and Repairs of Electrification at GHPS School at Chellur Village411388.68
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
289731394992None2.1.1Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required t complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregatesCum5947.25947.26.75FalseNoneNoneFalseNoneFalse40143.60
289731494992None9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1202.251202.2593.9FalseNoneNoneFalseNoneFalse112891.2750
289731594992NoneBasic RateRO Water Plant for Hemodialysis 500 Ltrs/Hr Capacity Specifications Plant capacity (Ltrs/Hr) 500 Plant type Microprocessor/microcontroller controlled single stage RO water system ( Feed water TDS more than 500 PPM) System type Online ,Offline Double raw water pump ( one active and the other stand by) No Raw water feed pump capacity (LPH) 1500 Micron particle filter after activated Carbon filter for removing suspended particles more than micron size 5 Distribution of RO plant water sufficient for number of dialysis machines 5-10 Material of Booster pump (offline) Stainless Steel 316Each166950.0166950.01.0FalseNoneNoneFalseNoneFalse166950.00
289731694992None13.11.1Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 3.00 HP - 300 LPM @ 26 m = 5 STG Outlet Dia - 2.50"Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289731794992None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Each24326.424326.41.0FalseNoneNoneFalseNoneFalse24326.40
289731894992None9.1.1Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0Mtr198.45198.4540.0FalseNoneNoneFalseNoneFalse7938.00
289731994992NoneBasic rateStainless Steel Top Loading Sanitary Napkin Incinerator Machine, Burning Ability: 500 Kg/timeEach24000.024000.01.0FalseNoneNoneFalseNoneFalse24000.00
289732094992None3.1.2Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854No147.0147.08.0FalseNoneNoneFalseNoneFalse1176.00
289732194992None9.3Supplying capacitor type ceiling fan complete with down rod blades shakle canopies for operation on 230V 50 cycles phase AC supply confirming to ISS 374-1979 and with double ball bearing system (84/9.3)No1900.01900.04.0FalseNoneNoneFalseNoneFalse7600.00
289732294992None11.14.2Supplyingandfixingofslimboxfitting,madeoutofCRCASheetmetalbodywithlockingtypeholdercompletelywired.ExcludingBallast & Fluorescent Tube. 1 x 4' Tube light fitting.No361.0361.03.0FalseNoneNoneFalseNoneFalse1083.00
289732394992NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1.5 SqmMtr26.026.06.0FalseNoneNoneFalseNoneFalse156.00
289732494992NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 SqmMtr42.042.07.0FalseNoneNoneFalseNoneFalse294.00
289732594992NoneP No 6Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 SqmMtr63.063.08.0FalseNoneNoneFalseNoneFalse504.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17094701000000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17094701000000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17094701000000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Qualification and experience of the key tec
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Owning the following key and critical equipment for this work
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of existing commitments and ongoing worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works for which tenders already submitted
NoneNoneNoneNoneBanker Details for referenceCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details for reference
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditors reports for the last five yearsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate 2018-19 to 2022-23 with UDIN No CompulsoryTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category Certificate ST CATEGORYTrueTechnical Bid
Tenderer must Submit PAN & GST Certificate.TrueTechnical Bid
Accurate postal address and phone / cell phone numberTrueTechnical Bid
Work orders / commitments of ongoing works issued by an officer not below the rank of Executive EngineerTrueTechnical Bid
Work done certificate of any Civil Work from Competent authority Rank of Executive Engineer & above 25 PercentageTrueTechnical Bid
Line of Credit 30 PercentageTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone