tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1709019900000 | 0 | None | None | Buildings | VACCINE STORE AT KARWAR -Civil Work. | 7229870.46 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2820539 | 91117 | None | Item 19.3 | Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge | Sqm | 144.05 | 144.05 | 395.0 | False | None | None | False | None | False | 56899.75 | 0 | 2820540 | 91117 | None | Item 19.7.3 | Demolishing brick work manually by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge. | Cum | 1042.74 | 1042.74 | 119.88 | False | None | None | False | None | False | 125003.6712 | 0 | 2820541 | 91117 | None | Item 19.9.2 | Demolishing stone rubble masonry manually by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin charge. | Cum | 1704.86 | 1704.86 | 67.95 | False | None | None | False | None | False | 115845.237 | 0 | 2820542 | 91117 | None | Item 19.12.1 | Dismantling doors, windows and clerestory windows steel or wood shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin charge. | Sqm | 243.17 | 243.17 | 71.61 | False | None | None | False | None | False | 17413.4037 | 0 | 2820543 | 91117 | None | Item 19.13.1 | Taking out doors, windows and clerestory window shutters steel or wood including stacking to the appropriate disposal area as per direction of Engineerincharge | Sqm | 95.15 | 95.15 | 71.61 | False | None | None | False | None | False | 6813.6915 | 0 | 2820544 | 91117 | None | Item 19.2.2 | Demolishing cement concrete manually by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineerincharge | Cum | 1683.71 | 1683.71 | 28.75 | False | None | None | False | None | False | 48406.6625 | 0 | 2820545 | 91117 | None | Item 19.3 | Demolishing R.C.C. work manually by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge.Chejja | Cum | 2455.53 | 2455.53 | 1.38 | False | None | None | False | None | False | 3388.6314 | 0 | 2820546 | 91117 | None | Item 2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. | ha | 208870.95 | 208870.95 | 0.0362 | False | None | None | False | None | False | 7561.12839 | 0 | 2820547 | 91117 | None | Item 1.12 | Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications, including etting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work. | Cum | 85.9 | 85.9 | 97.3 | False | None | None | False | None | False | 8358.07 | 0 | 2820548 | 91117 | None | Item 1.14.1 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work | Cum | 96.47 | 96.47 | 197.4231 | False | None | None | False | None | False | 19045.406457 | 0 | 2820549 | 91117 | None | Item 4.1 | Providing and injecting chemical emulsion for Preconstructional AntiTermite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percent E.C. Lindane 20percent E.C. at 3.19 lm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 125.55 | 125.55 | 389.0235 | False | None | None | False | None | False | 48841.900425 | 0 | 2820550 | 91117 | None | Item 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately | Cum | 7340.16 | 7340.16 | 48.34 | False | None | None | False | None | False | 354823.3344 | 0 | 2820551 | 91117 | None | Item 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trapbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork to be paid separatelyM20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for footing 8percent of concrete rate. | Cum | 8533.67 | 8533.67 | 24.53 | False | None | None | False | None | False | 209330.9251 | 0 | 2820552 | 91117 | None | Item 1.9 | Filling available excavated earth excluding rock in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 269.6 | 269.6 | 375.58 | False | None | None | False | None | False | 101256.368 | 0 | 2820553 | 91117 | None | Item 2.5.2 | COLUMNS : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for Column 70percent of concrete rate. | Cum | 13898.2 | 13898.2 | 9.16 | False | None | None | False | None | False | 127307.512 | 0 | 2820554 | 91117 | None | Item 2.5.2 | TERRACE FLOOR :Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 13979.96 | 13979.96 | 1.17 | False | None | None | False | None | False | 16356.5532 | 0 | 2820555 | 91117 | None | Item 2.5.2 | PLINTH BEAM Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam50percent of concrete rate | Cum | 12263.12 | 12263.12 | 36.11 | False | None | None | False | None | False | 442821.2632 | 0 | 2820556 | 91117 | None | Item 2.5.2 | LINTELS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam60percent of concrete rate | Cum | 13080.66 | 13080.66 | 5.14 | False | None | None | False | None | False | 67234.5924 | 0 | 2820557 | 91117 | None | Item 2.5.2 | ROOF BEAMS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam60percent of concrete rate | Cum | 13080.66 | 13080.66 | 17.64 | False | None | None | False | None | False | 230742.8424 | 0 | 2820558 | 91117 | None | Item 2.5.2 | ROOF SLAB Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam50percent of concrete rate | Cum | 12263.12 | 12263.12 | 36.79 | False | None | None | False | None | False | 451160.1848 | 0 | 2820559 | 91117 | None | Item 2.1.4 | CHEJJA : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 1:3:6 M10 Using 20 mm nominal size graded crushed coarse aggregates centring for chejja 45percent of concrete rate | Cum | 10976.68 | 10976.68 | 1.584 | False | None | None | False | None | False | 17387.06112 | 0 | 2820560 | 91117 | None | Item 2.1.4 | CILL : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 1:3:6 M10 Using 20 mm nominal size graded crushed coarse aggregates centring for CILL 8percent of concrete rate | Cum | 8175.73 | 8175.73 | 0.63 | False | None | None | False | None | False | 5150.7099 | 0 | 2820561 | 91117 | None | Item 17.4 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with CementEpoxy | No | 211.45 | 211.45 | 30.0 | False | None | None | False | None | False | 6343.5 | 0 | 2820562 | 91117 | None | Item 11.32 | Providing ThermoMechanically Treated bars of grade Fe500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. The laps and wastages shall not be measured separately Ground floor | Kg | 121.58 | 121.58 | 14073.43 | False | None | None | False | None | False | 1711047.6194 | 0 | 2820563 | 91117 | None | Item 11.32 | Providing ThermoMechanically Treated bars of grade Fe500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. The laps and wastages shall not be measured separately FIRST FLOOR add 1percent lift charge | Kg | 122.8 | 122.8 | 235.12 | False | None | None | False | None | False | 28872.736 | 0 | 2820564 | 91117 | None | Item 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOOR | Sqm | 1580.63 | 1580.63 | 465.25 | False | None | None | False | None | False | 735388.1075 | 0 | 2820565 | 91117 | None | Item 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications TERRACE add 1percent of lift charge | Sqm | 1596.43 | 1596.43 | 42.375 | False | None | None | False | None | False | 67648.72125 | 0 | 2820566 | 91117 | None | Item 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1242.3 | 1242.3 | 10.293 | False | None | None | False | None | False | 12786.9939 | 0 | 2820567 | 91117 | None | Item 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications. | Cum | 81414.52 | 81414.52 | 0.4 | False | None | None | False | None | False | 32565.808 | 0 | 2820568 | 91117 | None | Item 12.5 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1962.57 | 1962.57 | 7.0 | False | None | None | False | None | False | 13737.99 | 0 | 2820569 | 91117 | None | Item BPHL approved rate | Providing and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper and Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. Locking Arrangements | Nos | 5741.03 | 5741.03 | 7.0 | False | None | None | False | None | False | 40187.21 | 0 | 2820570 | 91117 | None | Item 10.6.3 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 39.64 | 39.64 | 39.0 | False | None | None | False | None | False | 1545.96 | 0 | 2820571 | 91117 | None | Item 313 0115 | Providing and Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Rmtr | 16.79 | 16.79 | 42.0 | False | None | None | False | None | False | 705.18 | 0 | 2820572 | 91117 | None | Item 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification. do 35 mm thick both side commercial | Sqm | 3890.79 | 3890.79 | 28.05 | False | None | None | False | None | False | 109136.6595 | 0 | 2820573 | 91117 | None | Item 12.9 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVCMatching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made | Sqm | 9568.38 | 9568.38 | 30.24 | False | None | None | False | None | False | 289347.8112 | 0 | 2820574 | 91117 | None | Item 12.85 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made GF | Sqm | 6436.19 | 6436.19 | 0.72 | False | None | None | False | None | False | 4634.0568 | 0 | 2820575 | 91117 | None | Item 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GF | Kg | 192.95 | 192.95 | 738.35 | False | None | None | False | None | False | 142464.6325 | 0 | 2820576 | 91117 | None | Item 12.54 | Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 6580mm size complete as per manufacturers specification and direction of Engineerincharge. | Sqm | 627.76 | 627.76 | 1.68 | False | None | None | False | None | False | 1054.6368 | 0 | 2820577 | 91117 | None | Item 12.55.2 | Providing and fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form stiles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75mm Aluminium hinges.Out side Prelam. | Sqm | 3774.48 | 3774.48 | 1.68 | False | None | None | False | None | False | 6341.1264 | 0 | 2820578 | 91117 | None | Item 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm, with necessary accessories and screws etc. complete. | Nos | 1163.0 | 1163.0 | 1.0 | False | None | None | False | None | False | 1163.0 | 0 | 2820579 | 91117 | None | Item 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Inside | Sqm | 388.55 | 388.55 | 529.79 | False | None | None | False | None | False | 205849.9045 | 0 | 2820580 | 91117 | None | Item 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. | Sqm | 362.11 | 362.11 | 404.63 | False | None | None | False | None | False | 146520.5693 | 0 | 2820581 | 91117 | None | Item 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 109.69 | 109.69 | 934.42 | False | None | None | False | None | False | 102496.5298 | 0 | 2820582 | 91117 | None | Item 8.51 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. . outside Ground Floor | Sqm | 405.73 | 405.73 | 295.46 | False | None | None | False | None | False | 119876.9858 | 0 | 2820583 | 91117 | None | Item 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. . outside TERRACE | Sqm | 409.78 | 409.78 | 116.56 | False | None | None | False | None | False | 47763.9568 | 0 | 2820584 | 91117 | None | Item 15.36 | Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment | Rmtr | 47.57 | 47.57 | 676.2 | False | None | None | False | None | False | 32166.834 | 0 | 2820585 | 91117 | None | Item 6.12 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 1 cement : 3 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1124.68 | 1124.68 | 7.19 | False | None | None | False | None | False | 8086.4492 | 0 | 2820586 | 91117 | None | Item 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. | Sqm | 285.46 | 285.46 | 25.0 | False | None | None | False | None | False | 7136.5 | 0 | 2820587 | 91117 | None | Item 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. | Rmtr | 52.86 | 52.86 | 271.0 | False | None | None | False | None | False | 14325.06 | 0 | 2820588 | 91117 | None | Item 9.19 | Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.. Size of Tile 600x600 mm | Sqm | 1629.53 | 1629.53 | 168.35 | False | None | None | False | None | False | 274331.3755 | 0 | 2820589 | 91117 | None | Item 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. | Sqm | 327.75 | 327.75 | 10.08 | False | None | None | False | None | False | 3303.72 | 0 | 2820590 | 91117 | None | Item 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 1 Cement : 4 Coarse sand, Jointing with grey cement slurry at 3.3 kgm2 including pointing the joints with white cement and matching pigment etc., complete. | Sqm | 799.56 | 799.56 | 2.02 | False | None | None | False | None | False | 1615.1112 | 0 | 2820591 | 91117 | None | Item 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1370.49 | 1370.49 | 10.08 | False | None | None | False | None | False | 13814.5392 | 0 | 2820592 | 91117 | None | Item 8.32 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gmlitre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 litre 10 m². Over and including priming coat of exterior primer applied at 0.90 litre10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. | Sqm | 148.01 | 148.01 | 934.42 | False | None | None | False | None | False | 138303.5042 | 0 | 2820593 | 91117 | None | Item 8.29 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 ltr10 m² over and including priming coat of exterior primer applied at 2.20kg10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops | Sqm | 274.89 | 274.89 | 82.4 | False | None | None | False | None | False | 22650.936 | 0 | 2820594 | 91117 | None | Item 8.31 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work Two coats applied at 1.43 ltr10 Sqm over and including priming coat of exterior primer applied at 2.20 kg10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. | Sqm | 174.45 | 174.45 | 329.62 | False | None | None | False | None | False | 57502.209 | 0 | 2820595 | 91117 | None | Item 8.4 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. | Sqm | 118.94 | 118.94 | 35.16 | False | None | None | False | None | False | 4181.9304 | 0 | 2820596 | 91117 | None | Item 8.38 | Painting with oil type wood preservative of approved brand and manufacture :New work two coats to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. | Sqm | 44.93 | 44.93 | 28.05 | False | None | None | False | None | False | 1260.2865 | 0 | 2820597 | 91117 | None | Item 10.1.2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand, joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 | Sqm | 4570.09 | 4570.09 | 9.0 | False | None | None | False | None | False | 41130.81 | 0 | 2820598 | 91117 | None | Item 15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceChajjasSunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT dry film thickness of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 984.59 | 984.59 | 219.86 | False | None | None | False | None | False | 216471.9574 | 0 | 2820599 | 91117 | None | Item 11.22.3 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge. | Kgs | 194.27 | 194.27 | 395.7 | False | None | None | False | None | False | 76872.639 | 0 | 2820600 | 91117 | None | Item 1201 | PVC pipes of 6 Kgcm2 for 110mm1.894 | Rmtr | 337.0 | 337.0 | 24.0 | False | None | None | False | None | False | 8088.0 | 0 |
| 1709019900000 | 0 | None | None | Buildings | VACCINE STORE AT KARWAR.-Electrical | 442013.92 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2820601 | 91118 | None | Item 1 | WIRES and CABLES :Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 296.18 | 296.18 | 9.0 | False | None | None | False | None | False | 2665.62 | 0 | 2820602 | 91118 | None | Item 2 | WIRES and CABLES: Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Point | 425.98 | 425.98 | 10.0 | False | None | None | False | None | False | 4259.8 | 0 | 2820603 | 91118 | None | Item 3 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm (Phase and Neutral and 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switch | Point | 639.56 | 639.56 | 10.0 | False | None | None | False | None | False | 6395.6 | 0 | 2820604 | 91118 | None | Item 4 | WIRES and CABLES Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm (Phase and Neutral and 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 791.78 | 791.78 | 10.0 | False | None | None | False | None | False | 7917.8 | 0 | 2820605 | 91118 | None | Item 5 | Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall1-3Way | Each | 145.14 | 145.14 | 4.0 | False | None | None | False | None | False | 580.56 | 0 | 2820606 | 91118 | None | Item 6 | Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 4-5Way | Each | 162.84 | 162.84 | 2.0 | False | None | None | False | None | False | 325.68 | 0 | 2820607 | 91118 | None | Item 7 | Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6Way | Each | 250.16 | 250.16 | 2.0 | False | None | None | False | None | False | 500.32 | 0 | 2820608 | 91118 | None | Item 8 | Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8Way | Each | 295.0 | 295.0 | 12.0 | False | None | None | False | None | False | 3540.0 | 0 | 2820609 | 91118 | None | Item 9 | Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 10-12Way | Each | 383.5 | 383.5 | 10.0 | False | None | None | False | None | False | 3835.0 | 0 | 2820610 | 91118 | None | Item 10 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1 to 3 Module | Each | 179.36 | 179.36 | 4.0 | False | None | None | False | None | False | 717.44 | 0 | 2820611 | 91118 | None | Item 11 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 4 Module | Each | 206.5 | 206.5 | 2.0 | False | None | None | False | None | False | 413.0 | 0 | 2820612 | 91118 | None | Item 12 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 6 Module | Each | 287.92 | 287.92 | 2.0 | False | None | None | False | None | False | 575.84 | 0 | 2820613 | 91118 | None | Item 13 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 8 Module | Each | 356.36 | 356.36 | 12.0 | False | None | None | False | None | False | 4276.32 | 0 | 2820614 | 91118 | None | Item 14 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 10-12 Module | Each | 428.34 | 428.34 | 10.0 | False | None | None | False | None | False | 4283.4 | 0 | 2820615 | 91118 | None | Item 15 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. | Each | 103.84 | 103.84 | 49.0 | False | None | None | False | None | False | 5088.16 | 0 | 2820616 | 91118 | None | Item 16 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. | Each | 1996.56 | 1996.56 | 10.0 | False | None | None | False | None | False | 19965.6 | 0 | 2820617 | 91118 | None | Item 17 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 369.34 | 369.34 | 9.0 | False | None | None | False | None | False | 3324.06 | 0 | 2820618 | 91118 | None | Item 18 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Each | 293.82 | 293.82 | 10.0 | False | None | None | False | None | False | 2938.2 | 0 | 2820619 | 91118 | None | Item 19 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch | Each | 442.5 | 442.5 | 10.0 | False | None | None | False | None | False | 4425.0 | 0 | 2820620 | 91118 | None | Item 20 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socket | Each | 293.82 | 293.82 | 20.0 | False | None | None | False | None | False | 5876.4 | 0 | 2820621 | 91118 | None | Item 21 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socket | Nos | 173.46 | 173.46 | 1.0 | False | None | None | False | None | False | 173.46 | 0 | 2820622 | 91118 | None | Item 22 | Supplyin and Fixing Metal Fan Box with Round Hook. | Nos | 192.34 | 192.34 | 9.0 | False | None | None | False | None | False | 1731.06 | 0 | 2820623 | 91118 | None | Item 23 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB.The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box and wired Completely. 20Amps SP | Nos | 1030.14 | 1030.14 | 2.0 | False | None | None | False | None | False | 2060.28 | 0 | 2820624 | 91118 | None | Item 24 | Supplying and fixing of MODULAR MCB Devices(Tripper With Breaking capacity of 6KA 16-32Amps SP | Nos | 224.2 | 224.2 | 2.0 | False | None | None | False | None | False | 448.4 | 0 | 2820625 | 91118 | None | Item 25 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thick | Mtr | 71.98 | 71.98 | 250.0 | False | None | None | False | None | False | 17995.0 | 0 | 2820626 | 91118 | None | Item 26 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thick | Mtr | 82.6 | 82.6 | 300.0 | False | None | None | False | None | False | 24780.0 | 0 | 2820627 | 91118 | None | Item 27 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thick | Mtr | 88.5 | 88.5 | 90.0 | False | None | None | False | None | False | 7965.0 | 0 | 2820628 | 91118 | None | Item 28 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 94.4 | 94.4 | 120.0 | False | None | None | False | None | False | 11328.0 | 0 | 2820629 | 91118 | None | Item 29 | WIRING FOR LightingorPower Circuits : Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm | Mtr | 30.68 | 30.68 | 110.0 | False | None | None | False | None | False | 3374.8 | 0 | 2820630 | 91118 | None | Item 30 | WIRING FOR LightingorPower Circuits : Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm | Mtr | 47.19 | 47.19 | 390.0 | False | None | None | False | None | False | 18404.1 | 0 | 2820631 | 91118 | None | Item 31 | WIRING FOR LightingorPower Circuits : Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm | Mtr | 69.62 | 69.62 | 350.0 | False | None | None | False | None | False | 24367.0 | 0 | 2820632 | 91118 | None | Item 32 | MCB DB : Supplying and fixing regular MCB distribution boards on wall or wood board I flush mounting using required clamps ,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door 12 Way SP and N | Each | 1877.38 | 1877.38 | 1.0 | False | None | None | False | None | False | 1877.38 | 0 | 2820633 | 91118 | None | Item 33 | MCB DB : Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door 6 Way TP and N | Each | 4407.3 | 4407.3 | 1.0 | False | None | None | False | None | False | 4407.3 | 0 | 2820634 | 91118 | None | Item 34 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 617.14 | 617.14 | 28.0 | False | None | None | False | None | False | 17279.92 | 0 | 2820635 | 91118 | None | Item 35 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN | Each | 2823.74 | 2823.74 | 1.0 | False | None | None | False | None | False | 2823.74 | 0 | 2820636 | 91118 | None | Item 36 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 16-25 Amps 2 pole | Each | 2992.48 | 2992.48 | 1.0 | False | None | None | False | None | False | 2992.48 | 0 | 2820637 | 91118 | None | Item 37 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 32-40 Amps 4 pole | Each | 3334.68 | 3334.68 | 1.0 | False | None | None | False | None | False | 3334.68 | 0 | 2820638 | 91118 | None | Item 38 | LT UG CABLES Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1 or IS-7098 Part-1, Armouring strip thickness in average +5Percent and resistivity 14 OhmsorKms (Max as per IS-39754 core 16 sqmm | Mtr | 177.0 | 177.0 | 100.0 | False | None | None | False | None | False | 17700.0 | 0 | 2820639 | 91118 | None | Item 39 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe or stoneware pipe or on wall or on pole as required. 6 sqmm to 16 sqmm | Mtr | 35.4 | 35.4 | 100.0 | False | None | None | False | None | False | 3540.0 | 0 | 2820640 | 91118 | None | Item 40 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only 32mm dia | Each | 138.06 | 138.06 | 4.0 | False | None | None | False | None | False | 552.24 | 0 | 2820641 | 91118 | None | Item 41 | Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7 In soil (hard | Mtr | 120.36 | 120.36 | 50.0 | False | None | None | False | None | False | 6018.0 | 0 | 2820642 | 91118 | None | Item 42 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm | Each | 14.67 | 14.67 | 10.0 | False | None | None | False | None | False | 146.7 | 0 | 2820643 | 91118 | None | Item 43 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. | No | 3539.64 | 3539.64 | 2.0 | False | None | None | False | None | False | 7079.28 | 0 | 2820644 | 91118 | None | Item 44 | Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x3mm | Mtr | 88.5 | 88.5 | 30.0 | False | None | None | False | None | False | 2655.0 | 0 | 2820645 | 91118 | None | Item 45 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours and 70Percent lumen maintenance with CRI 80. Power Input: 220-240V at 50or60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20or22 w | Each | 873.19 | 873.19 | 34.0 | False | None | None | False | None | False | 29688.46 | 0 | 2820646 | 91118 | None | Item 46 | Supplying and fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70Percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5Percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20Percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.7 W, 6500K | Each | 174.64 | 174.64 | 1.0 | False | None | None | False | None | False | 174.64 | 0 | 2820647 | 91118 | None | Item 47 | Supplying and Fixing of 70-150 Watts lamp holder 2 Pin | Each | 125.08 | 125.08 | 1.0 | False | None | None | False | None | False | 125.08 | 0 | 2820648 | 91118 | None | Item 48 | Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 1819.56 | 1819.56 | 1.0 | False | None | None | False | None | False | 1819.56 | 0 | 2820649 | 91118 | None | Item 49 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mm | Each | 3536.46 | 3536.46 | 1.0 | False | None | None | False | None | False | 3536.46 | 0 | 2820650 | 91118 | None | Item 50 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm Regular model | Each | 2460.29 | 2460.29 | 9.0 | False | None | None | False | None | False | 22142.61 | 0 | 2820651 | 91118 | None | Item 51 | Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall or ceiling or Rafter or Girders | Each | 140.42 | 140.42 | 34.0 | False | None | None | False | None | False | 4774.28 | 0 | 2820652 | 91118 | None | Item 52 | Fixing a ceiling or Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 or 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 191.16 | 191.16 | 9.0 | False | None | None | False | None | False | 1720.44 | 0 | 2820653 | 91118 | None | Item 53 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 828.36 | 828.36 | 2.0 | False | None | None | False | None | False | 1656.72 | 0 | 2820654 | 91118 | None | Item 54 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70Percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lmorw, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source. LED Streetlight 70watts | No | 7026.9 | 7026.9 | 3.0 | False | None | None | False | None | False | 21080.7 | 0 | 2820655 | 91118 | None | Item 55 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts and nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories.Single bracket 1.5 Mtr. Length | Each | 1529.28 | 1529.28 | 3.0 | False | None | None | False | None | False | 4587.84 | 0 | 2820656 | 91118 | None | Item 56 | Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 223.02 | 223.02 | 3.0 | False | None | None | False | None | False | 669.06 | 0 | 2820657 | 91118 | None | Item 57 | LT Panel : Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG | Sq CM | 0.45 | 0.45 | 90000.0 | False | None | None | False | None | False | 40500.0 | 0 | 2820658 | 91118 | None | Item 58 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips | Mtr | 2612.52 | 2612.52 | 2.0 | False | None | None | False | None | False | 5225.04 | 0 | 2820659 | 91118 | None | Item 59 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm | Mtr | 324.5 | 324.5 | 6.0 | False | None | None | False | None | False | 1947.0 | 0 | 2820660 | 91118 | None | Item 60 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel | Mtr | 802.4 | 802.4 | 6.0 | False | None | None | False | None | False | 4814.4 | 0 | 2820661 | 91118 | None | Item 61 | Supplying and fixing Moulded Case Circuit Breaker (MCCB .over the existing woodorpanel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal MagneticorMicro processor release and Earth Fault as per IS-13947. (lcu= lcs FOUR POLE 100Amps 25kA | Each | 9752.69 | 9752.69 | 1.0 | False | None | None | False | None | False | 9752.69 | 0 | 2820662 | 91118 | None | Item 62 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN | Each | 2823.74 | 2823.74 | 2.0 | False | None | None | False | None | False | 5647.48 | 0 | 2820663 | 91118 | None | Item 63 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP | Each | 1301.54 | 1301.54 | 2.0 | False | None | None | False | None | False | 2603.08 | 0 | 2820664 | 91118 | None | Item 64 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 617.14 | 617.14 | 3.0 | False | None | None | False | None | False | 1851.42 | 0 | 2820665 | 91118 | None | Item 65 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.C | Each | 547.52 | 547.52 | 2.0 | False | None | None | False | None | False | 1095.04 | 0 | 2820666 | 91118 | None | Item 66 | Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound | Each | 595.9 | 595.9 | 3.0 | False | None | None | False | None | False | 1787.7 | 0 | 2820667 | 91118 | None | Item 67 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9876.6 | 9876.6 | 1.0 | False | None | None | False | None | False | 9876.6 | 0 |
| 1709019900000 | 0 | None | None | Buildings | VACCINE STORE AT KARWAR - Water Supply and Sanitary Work | 285691.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2820668 | 91119 | None | Item 1 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work For Sewer allround For water supply line from BW to building | Cum | 96.48 | 96.48 | 36.0 | False | None | None | False | None | False | 3473.28 | 0 | 2820669 | 91119 | None | Item 2 | Refilling available earth around trenchesorpipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m.
Including cost of all labour complete as per specifications | Cum | 161.24 | 161.24 | 36.0 | False | None | None | False | None | False | 5804.64 | 0 | 2820670 | 91119 | None | Item 4 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm dia pipes, From Sink | m | 183.7 | 183.7 | 5.0 | False | None | None | False | None | False | 918.5 | 0 | 2820671 | 91119 | None | Item 5 | Providing and fixing PVC pipe . OD 75mm and 6 Kgorsqcm, waste lines 75mm dia pipes, waste lines | m | 162.56 | 162.56 | 15.0 | False | None | None | False | None | False | 2438.4 | 0 | 2820672 | 91119 | None | Item 6 | Providing and fixing PVC pipe . OD 110mm and 6 Kgorsqcm, sanitary lines 110mm dia pipes, sanitary lines | m | 337.01 | 337.01 | 10.0 | False | None | None | False | None | False | 3370.1 | 0 | 2820673 | 91119 | None | Item 7 | Providing and fixing PVC pipe . OD 160mm,200mm and 6 Kgorsqcm, sanitary lines . 160 mm dia | m | 555.07 | 555.07 | 100.0 | False | None | None | False | None | False | 55507.0 | 0 | 2820674 | 91119 | None | Item 8 | Providing and fixing PVC pipe . OD 160mm,200mm and 6 Kgorsqcm, sanitary lines . 200 mm dia | m | 1098.25 | 1098.25 | 10.0 | False | None | None | False | None | False | 10982.5 | 0 | 2820675 | 91119 | None | Item 9 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i) the single socketed pipes 75mm diameter 75mm RWP | m | 233.92 | 233.92 | 5.0 | False | None | None | False | None | False | 1169.6 | 0 | 2820676 | 91119 | None | Item 10 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter 110mm RWP | m | 334.36 | 334.36 | 15.0 | False | None | None | False | None | False | 5015.4 | 0 | 2820677 | 91119 | None | Item 11 | Providing and fixing trap of self cleansing design with screw down or hinged grating with or wihtuot vent arm complete,including cost of cutting and making good the walls and floors 10Cms X 7.5Cms | Nos. | 627.76 | 627.76 | 2.0 | False | None | None | False | None | False | 1255.52 | 0 | 2820678 | 91119 | None | Item 12 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover. | Nos. | 6577.6 | 6577.6 | 10.0 | False | None | None | False | None | False | 65776.0 | 0 | 2820679 | 91119 | None | Item 13 | Providing 15x10cms stoneware gully trap of approved quality and make and fixing in C.C.1:2:4 and plastering with CM 1:3 wherever necessary complete. (Rate includes cost of all materials and fixtures and lead. | Nos. | 370.05 | 370.05 | 2.0 | False | None | None | False | None | False | 740.1 | 0 | 2820680 | 91119 | None | Item 14 | Sanitary and CP fixtures : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinamflushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid | Nos. | 6614.61 | 6614.61 | 1.0 | False | None | None | False | None | False | 6614.61 | 0 | 2820681 | 91119 | None | Item 15 | Supplying, fixing, testing and commissioning of CP health faucet consisting of: 1 No. 15mm dia CP Angle cock with wall flange. PVC flexible tube of 1.00m long tube with end nuts. Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. Make: Jaquar or equivalent.MODEL NO: ALD.CHR.565 | Nos. | 2444.96 | 2444.96 | 1.0 | False | None | None | False | None | False | 2444.96 | 0 | 2820682 | 91119 | None | Item 16 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm | Nos. | 4703.57 | 4703.57 | 1.0 | False | None | None | False | None | False | 4703.57 | 0 | 2820683 | 91119 | None | Item 17 | Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON.CHR.347KN for pantry sink with CP wall flange etc. Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent ) | Nos | 2236.14 | 2236.14 | 1.0 | False | None | None | False | None | False | 2236.14 | 0 | 2820684 | 91119 | None | Item 18 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Each | 3342.33 | 3342.33 | 1.0 | False | None | None | False | None | False | 3342.33 | 0 | 2820685 | 91119 | None | Item 19 | WATER SUPPLY : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. .15 mm dia | m | 404.4 | 404.4 | 5.0 | False | None | None | False | None | False | 2022.0 | 0 | 2820686 | 91119 | None | Item 20 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia | m | 492.96 | 492.96 | 20.0 | False | None | None | False | None | False | 9859.2 | 0 | 2820687 | 91119 | None | Item 21 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm dia | m | 629.08 | 629.08 | 50.0 | False | None | None | False | None | False | 31454.0 | 0 | 2820688 | 91119 | None | Item 22 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.(External work)(V.2,It. No. Dwd SR 2021.22) External and Shafts and Terrace . 25mm DWS | m | 395.16 | 395.16 | 30.0 | False | None | None | False | None | False | 11854.8 | 0 | 2820689 | 91119 | None | Item 23 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. | l | 10.57 | 10.57 | 1000.0 | False | None | None | False | None | False | 10570.0 | 0 | 2820690 | 91119 | None | Item 24 | Providing fixing in position nominal bore non return valve horizontal type of approved make including cost of all materials,labour and HOM with all leads complete as per specifications a) 25 mm dia | Nos | 775.78 | 775.78 | 1.0 | False | None | None | False | None | False | 775.78 | 0 | 2820691 | 91119 | None | Item 25 | Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality nominal bore including cost of all materials ,labour and HOM with all leads complete as per specifications.KSRB 13.6.4.2 25mm dia | Nos | 677.98 | 677.98 | 3.0 | False | None | None | False | None | False | 2033.94 | 0 | 2820692 | 91119 | None | Item 26 | Providing and construction Soak pit as per IS 24701 P1and II and relevant construction drawing. The pit shall be construction of RCC Rings with RCC top slab and PCC bed at bottom and Recharge pit Filling of 40mm jelly and sandSize of (SOAK pit:. 1.2m dia x 3.0mdepth) | Nos | 23719.18 | 23719.18 | 1.0 | False | None | None | False | None | False | 23719.18 | 0 | 2820693 | 91119 | None | Item 27 | Supplying, installing, testing and commissioning approved make submersible pump made of C.I Construction suitable for building application. (Submersible Single phase 4 inchor100mm,1HP) | Nos | 17610.32 | 17610.32 | 1.0 | False | None | None | False | None | False | 17610.32 | 0 |
|
|
---|