createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709019899945
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1990.00
emd160000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-03-2024 16:00:00
tenderQueryClose11-03-2024 16:00:00
technicalBidOpen14-03-2024 16:30:00
publishedDate04-03-2024 15:14:46
publishedByPostEWHFWD_EE_EEOFF_DWD
publishedByUserKPE13493 - SURESH S N
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonM A Kalasageri
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08362955800
mobileNumber9449843329
tenderSupplierListNone
tenderSchedule
createdTs1709019899969
version4
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT171
titleCONSTRUCTION OF VACCINE STORE AT KARWAR IN UTTARA KANNADA DISTRICT.
descriptionCONSTRUCTION OF VACCINE STORE AT KARWAR IN UTTARA KANNADA DISTRICT.
categoryWORKS
categoryTextWorks
ecv7957576.25
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3524
locationNameEWHFWD Executive Engineer Office Dharwad
provisionalAmount8100000.0
groupOverheadTotal0.0
fileNumberhfw/eng/subdvn/dwd-13/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17090199000000NoneNoneBuildingsVACCINE STORE AT KARWAR -Civil Work.7229870.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
282053991117NoneItem 19.3Dismantling tiled roofing with battens, boarding etc. complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of EngineerinchargeSqm144.05144.05395.0FalseNoneNoneFalseNoneFalse56899.750
282054091117NoneItem 19.7.3Demolishing brick work manually by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge.Cum1042.741042.74119.88FalseNoneNoneFalseNoneFalse125003.67120
282054191117NoneItem 19.9.2Demolishing stone rubble masonry manually by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin charge.Cum1704.861704.8667.95FalseNoneNoneFalseNoneFalse115845.2370
282054291117NoneItem 19.12.1Dismantling doors, windows and clerestory windows steel or wood shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin charge.Sqm243.17243.1771.61FalseNoneNoneFalseNoneFalse17413.40370
282054391117NoneItem 19.13.1Taking out doors, windows and clerestory window shutters steel or wood including stacking to the appropriate disposal area as per direction of EngineerinchargeSqm95.1595.1571.61FalseNoneNoneFalseNoneFalse6813.69150
282054491117NoneItem 19.2.2Demolishing cement concrete manually by mechanical means including disposal of material to the appropriate disposal area as per direction of EngineerinchargeCum1683.711683.7128.75FalseNoneNoneFalseNoneFalse48406.66250
282054591117NoneItem 19.3Demolishing R.C.C. work manually by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerincharge.ChejjaCum2455.532455.531.38FalseNoneNoneFalseNoneFalse3388.63140
282054691117NoneItem 2.5AClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.ha208870.95208870.950.0362FalseNoneNoneFalseNoneFalse7561.128390
282054791117NoneItem 1.12Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications, including etting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work.Cum85.985.997.3FalseNoneNoneFalseNoneFalse8358.070
282054891117NoneItem 1.14.1Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the workCum96.4796.47197.4231FalseNoneNoneFalseNoneFalse19045.4064570
282054991117NoneItem 4.1Providing and injecting chemical emulsion for Preconstructional AntiTermite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percent E.C. Lindane 20percent E.C. at 3.19 lm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm125.55125.55389.0235FalseNoneNoneFalseNoneFalse48841.9004250
282055091117NoneItem 2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separatelyCum7340.167340.1648.34FalseNoneNoneFalseNoneFalse354823.33440
282055191117NoneItem 2.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trapbasalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork to be paid separatelyM20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for footing 8percent of concrete rate.Cum8533.678533.6724.53FalseNoneNoneFalseNoneFalse209330.92510
282055291117NoneItem 1.9Filling available excavated earth excluding rock in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 0cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum269.6269.6375.58FalseNoneNoneFalseNoneFalse101256.3680
282055391117NoneItem 2.5.2COLUMNS : Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for Column 70percent of concrete rate.Cum13898.213898.29.16FalseNoneNoneFalseNoneFalse127307.5120
282055491117NoneItem 2.5.2TERRACE FLOOR :Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum13979.9613979.961.17FalseNoneNoneFalseNoneFalse16356.55320
282055591117NoneItem 2.5.2PLINTH BEAM Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam50percent of concrete rateCum12263.1212263.1236.11FalseNoneNoneFalseNoneFalse442821.26320
282055691117NoneItem 2.5.2LINTELS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam60percent of concrete rateCum13080.6613080.665.14FalseNoneNoneFalseNoneFalse67234.59240
282055791117NoneItem 2.5.2ROOF BEAMS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam60percent of concrete rateCum13080.6613080.6617.64FalseNoneNoneFalseNoneFalse230742.84240
282055891117NoneItem 2.5.2ROOF SLAB Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars and formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates centring for plinth beam50percent of concrete rateCum12263.1212263.1236.79FalseNoneNoneFalseNoneFalse451160.18480
282055991117NoneItem 2.1.4CHEJJA : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 1:3:6 M10 Using 20 mm nominal size graded crushed coarse aggregates centring for chejja 45percent of concrete rateCum10976.6810976.681.584FalseNoneNoneFalseNoneFalse17387.061120
282056091117NoneItem 2.1.4CILL : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement and formwork shall be paid separately Mix 1:3:6 M10 Using 20 mm nominal size graded crushed coarse aggregates centring for CILL 8percent of concrete rateCum8175.738175.730.63FalseNoneNoneFalseNoneFalse5150.70990
282056191117NoneItem 17.4Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with CementEpoxyNo211.45211.4530.0FalseNoneNoneFalseNoneFalse6343.50
282056291117NoneItem 11.32Providing ThermoMechanically Treated bars of grade Fe500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. The laps and wastages shall not be measured separately Ground floorKg121.58121.5814073.43FalseNoneNoneFalseNoneFalse1711047.61940
282056391117NoneItem 11.32Providing ThermoMechanically Treated bars of grade Fe500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. The laps and wastages shall not be measured separately FIRST FLOOR add 1percent lift chargeKg122.8122.8235.12FalseNoneNoneFalseNoneFalse28872.7360
282056491117NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOORSqm1580.631580.63465.25FalseNoneNoneFalseNoneFalse735388.10750
282056591117NoneItem 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications TERRACE add 1percent of lift chargeSqm1596.431596.4342.375FalseNoneNoneFalseNoneFalse67648.721250
282056691117NoneItem 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1242.31242.310.293FalseNoneNoneFalseNoneFalse12786.99390
282056791117NoneItem 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps, but including cost of materials, labour, usage charges complete as per specifications.Cum81414.5281414.520.4FalseNoneNoneFalseNoneFalse32565.8080
282056891117NoneItem 12.5Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1962.571962.577.0FalseNoneNoneFalseNoneFalse13737.990
282056991117NoneItem BPHL approved rateProviding and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper and Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. Locking ArrangementsNos5741.035741.037.0FalseNoneNoneFalseNoneFalse40187.210
282057091117NoneItem 10.6.3Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmNos39.6439.6439.0FalseNoneNoneFalseNoneFalse1545.960
282057191117NoneItem 313 0115Providing and Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications.Rmtr16.7916.7942.0FalseNoneNoneFalseNoneFalse705.180
282057291117NoneItem 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification. do 35 mm thick both side commercialSqm3890.793890.7928.05FalseNoneNoneFalseNoneFalse109136.65950
282057391117NoneItem 12.9Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVCMatching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be madeSqm9568.389568.3830.24FalseNoneNoneFalseNoneFalse289347.81120
282057491117NoneItem 12.85Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2Titanium Dioxide at 6PHR with TPEThermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made GFSqm6436.196436.190.72FalseNoneNoneFalseNoneFalse4634.05680
282057591117NoneItem 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GFKg192.95192.95738.35FalseNoneNoneFalseNoneFalse142464.63250
282057691117NoneItem 12.54Providing and fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners and jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 6580mm size complete as per manufacturers specification and direction of Engineerincharge.Sqm627.76627.761.68FalseNoneNoneFalseNoneFalse1054.63680
282057791117NoneItem 12.55.2Providing and fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top and bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet and 30x50mm wide to form stiles and 5mm thick and 75mm wide Prelaminated PVC Sheets for top rail, lock rail and bottom rail on either side and 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail and bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles and rails with PVC Designer beading on either side and joined together with solvent cement adhesive etc., Complete as per manufacturers specification and direction of Engineerincharge fixed to frames with 3 nos of 75mm Aluminium hinges.Out side Prelam.Sqm3774.483774.481.68FalseNoneNoneFalseNoneFalse6341.12640
282057891117NoneItem 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm, with necessary accessories and screws etc. complete.Nos1163.01163.01.0FalseNoneNoneFalseNoneFalse1163.00
282057991117NoneItem 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. InsideSqm388.55388.55529.79FalseNoneNoneFalseNoneFalse205849.90450
282058091117NoneItem 8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.Sqm362.11362.11404.63FalseNoneNoneFalseNoneFalse146520.56930
282058191117NoneItem 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm109.69109.69934.42FalseNoneNoneFalseNoneFalse102496.52980
282058291117NoneItem 8.51Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. . outside Ground FloorSqm405.73405.73295.46FalseNoneNoneFalseNoneFalse119876.98580
282058391117NoneItem 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. . outside TERRACESqm409.78409.78116.56FalseNoneNoneFalseNoneFalse47763.95680
282058491117NoneItem 15.36Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for paymentRmtr47.5747.57676.2FalseNoneNoneFalseNoneFalse32166.8340
282058591117NoneItem 6.12Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 1 cement : 3 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work.Sqm1124.681124.687.19FalseNoneNoneFalseNoneFalse8086.44920
282058691117NoneItem 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.Sqm285.46285.4625.0FalseNoneNoneFalseNoneFalse7136.50
282058791117NoneItem 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove.Rmtr52.8652.86271.0FalseNoneNoneFalseNoneFalse14325.060
282058891117NoneItem 9.19Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer, with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately.. Size of Tile 600x600 mmSqm1629.531629.53168.35FalseNoneNoneFalseNoneFalse274331.37550
282058991117NoneItem 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.Sqm327.75327.7510.08FalseNoneNoneFalseNoneFalse3303.720
282059091117NoneItem 9.9Providing and laying Ceramic glazed floor tiles of size 300x300 mm thickness to be specified by the manufacturer of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 1 Cement : 4 Coarse sand, Jointing with grey cement slurry at 3.3 kgm2 including pointing the joints with white cement and matching pigment etc., complete.Sqm799.56799.562.02FalseNoneNoneFalseNoneFalse1615.11120
282059191117NoneItem 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1370.491370.4910.08FalseNoneNoneFalseNoneFalse13814.53920
282059291117NoneItem 8.32Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gmlitre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 litre 10 m². Over and including priming coat of exterior primer applied at 0.90 litre10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.Sqm148.01148.01934.42FalseNoneNoneFalseNoneFalse138303.50420
282059391117NoneItem 8.29Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 ltr10 m² over and including priming coat of exterior primer applied at 2.20kg10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar dropsSqm274.89274.8982.4FalseNoneNoneFalseNoneFalse22650.9360
282059491117NoneItem 8.31Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work Two coats applied at 1.43 ltr10 Sqm over and including priming coat of exterior primer applied at 2.20 kg10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.Sqm174.45174.45329.62FalseNoneNoneFalseNoneFalse57502.2090
282059591117NoneItem 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.Sqm118.94118.9435.16FalseNoneNoneFalseNoneFalse4181.93040
282059691117NoneItem 8.38Painting with oil type wood preservative of approved brand and manufacture :New work two coats to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.Sqm44.9344.9328.05FalseNoneNoneFalseNoneFalse1260.28650
282059791117NoneItem 10.1.2Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand, joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2Sqm4570.094570.099.0FalseNoneNoneFalseNoneFalse41130.810
282059891117NoneItem 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceChajjasSunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT dry film thickness of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.Sqm984.59984.59219.86FalseNoneNoneFalseNoneFalse216471.95740
282059991117NoneItem 11.22.3Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge.Kgs194.27194.27395.7FalseNoneNoneFalseNoneFalse76872.6390
282060091117NoneItem 1201PVC pipes of 6 Kgcm2 for 110mm1.894Rmtr337.0337.024.0FalseNoneNoneFalseNoneFalse8088.00
17090199000000NoneNoneBuildingsVACCINE STORE AT KARWAR.-Electrical442013.92
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
282060191118NoneItem 1WIRES and CABLES :Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchPoint296.18296.189.0FalseNoneNoneFalseNoneFalse2665.620
282060291118NoneItem 2WIRES and CABLES: Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Medium point above 3mtr up to 6Mtr from tapping point to out let via switchPoint425.98425.9810.0FalseNoneNoneFalseNoneFalse4259.80
282060391118NoneItem 3Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm (Phase and Neutral and 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Above 6Mtr up to 10Mtr from tapping Point to out let via switchPoint639.56639.5610.0FalseNoneNoneFalseNoneFalse6395.60
282060491118NoneItem 4WIRES and CABLES Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit orcasing capping casing capping using 2x1.5Sqmm (Phase and Neutral and 1x1.0 sqmm (Earth wire FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments without control switch shall be fixed on the existing plastic sheetor gang box, the other end of the wires shall be terminated with sufficient loose length in a woodorPVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesPoint791.78791.7810.0FalseNoneNoneFalseNoneFalse7917.80
282060591118NoneItem 5Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall1-3WayEach145.14145.144.0FalseNoneNoneFalseNoneFalse580.560
282060691118NoneItem 6Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 4-5WayEach162.84162.842.0FalseNoneNoneFalseNoneFalse325.680
282060791118NoneItem 7Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 6WayEach250.16250.162.0FalseNoneNoneFalseNoneFalse500.320
282060891118NoneItem 8Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 8WayEach295.0295.012.0FalseNoneNoneFalseNoneFalse3540.00
282060991118NoneItem 9Supplying and flush mounting powder coated or galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in BrickorStoneorC.C wall 10-12WayEach383.5383.510.0FalseNoneNoneFalseNoneFalse3835.00
282061091118NoneItem 10Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box.1 to 3 ModuleEach179.36179.364.0FalseNoneNoneFalseNoneFalse717.440
282061191118NoneItem 11Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 4 ModuleEach206.5206.52.0FalseNoneNoneFalseNoneFalse413.00
282061291118NoneItem 12Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 6 ModuleEach287.92287.922.0FalseNoneNoneFalseNoneFalse575.840
282061391118NoneItem 13Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 8 ModuleEach356.36356.3612.0FalseNoneNoneFalseNoneFalse4276.320
282061491118NoneItem 14Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalorPVC box. 10-12 ModuleEach428.34428.3410.0FalseNoneNoneFalseNoneFalse4283.40
282061591118NoneItem 15Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way.Each103.84103.8449.0FalseNoneNoneFalseNoneFalse5088.160
282061691118NoneItem 16Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket.Each1996.561996.5610.0FalseNoneNoneFalseNoneFalse19965.60
282061791118NoneItem 17Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.Each369.34369.349.0FalseNoneNoneFalseNoneFalse3324.060
282061891118NoneItem 18Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchEach293.82293.8210.0FalseNoneNoneFalseNoneFalse2938.20
282061991118NoneItem 19Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchEach442.5442.510.0FalseNoneNoneFalseNoneFalse4425.00
282062091118NoneItem 20Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6or16Amps universal socketEach293.82293.8220.0FalseNoneNoneFalseNoneFalse5876.40
282062191118NoneItem 21Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TVorTelephone socketNos173.46173.461.0FalseNoneNoneFalseNoneFalse173.460
282062291118NoneItem 22Supplyin and Fixing Metal Fan Box with Round Hook.Nos192.34192.349.0FalseNoneNoneFalseNoneFalse1731.060
282062391118NoneItem 23Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB.The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box and wired Completely. 20Amps SPNos1030.141030.142.0FalseNoneNoneFalseNoneFalse2060.280
282062491118NoneItem 24Supplying and fixing of MODULAR MCB Devices(Tripper With Breaking capacity of 6KA 16-32Amps SPNos224.2224.22.0FalseNoneNoneFalseNoneFalse448.40
282062591118NoneItem 25Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 19or20mm dia 2mm thickMtr71.9871.98250.0FalseNoneNoneFalseNoneFalse17995.00
282062691118NoneItem 26Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2or2 25mm dia 2mm thickMtr82.682.6300.0FalseNoneNoneFalseNoneFalse24780.00
282062791118NoneItem 27Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19or20mm dia 2mm thickMtr88.588.590.0FalseNoneNoneFalseNoneFalse7965.00
282062891118NoneItem 28Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metalorPVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickMtr94.494.4120.0FalseNoneNoneFalseNoneFalse11328.00
282062991118NoneItem 29WIRING FOR LightingorPower Circuits : Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmMtr30.6830.68110.0FalseNoneNoneFalseNoneFalse3374.80
282063091118NoneItem 30WIRING FOR LightingorPower Circuits : Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmMtr47.1947.19390.0FalseNoneNoneFalseNoneFalse18404.10
282063191118NoneItem 31WIRING FOR LightingorPower Circuits : Wiring for lightingorpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmMtr69.6269.62350.0FalseNoneNoneFalseNoneFalse24367.00
282063291118NoneItem 32MCB DB : Supplying and fixing regular MCB distribution boards on wall or wood board I flush mounting using required clamps ,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door 12 Way SP and NEach1877.381877.381.0FalseNoneNoneFalseNoneFalse1877.380
282063391118NoneItem 33MCB DB : Supplying and fixing regular MCB distribution boards on wallor wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure( Double Door 6 Way TP and NEach4407.34407.31.0FalseNoneNoneFalseNoneFalse4407.30
282063491118NoneItem 34Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach617.14617.1428.0FalseNoneNoneFalseNoneFalse17279.920
282063591118NoneItem 35Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach2823.742823.741.0FalseNoneNoneFalseNoneFalse2823.740
282063691118NoneItem 36Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 16-25 Amps 2 poleEach2992.482992.481.0FalseNoneNoneFalseNoneFalse2992.480
282063791118NoneItem 37Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240or450V up to 300mA sensitivity on existing woodorpanel board 32-40 Amps 4 poleEach3334.683334.681.0FalseNoneNoneFalseNoneFalse3334.680
282063891118NoneItem 38LT UG CABLES Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1 or IS-7098 Part-1, Armouring strip thickness in average +5Percent and resistivity 14 OhmsorKms (Max as per IS-39754 core 16 sqmmMtr177.0177.0100.0FalseNoneNoneFalseNoneFalse17700.00
282063991118NoneItem 39Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe or stoneware pipe or on wall or on pole as required. 6 sqmm to 16 sqmmMtr35.435.4100.0FalseNoneNoneFalseNoneFalse3540.00
282064091118NoneItem 40Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only 32mm diaEach138.06138.064.0FalseNoneNoneFalseNoneFalse552.240
282064191118NoneItem 41Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7 In soil (hardMtr120.36120.3650.0FalseNoneNoneFalseNoneFalse6018.00
282064291118NoneItem 42Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmmEach14.6714.6710.0FalseNoneNoneFalseNoneFalse146.70
282064391118NoneItem 43Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.No3539.643539.642.0FalseNoneNoneFalseNoneFalse7079.280
282064491118NoneItem 44Supplying and running of GIorCopper strips for grounding connections, using necessary fixing materials as required. 25x3mmMtr88.588.530.0FalseNoneNoneFalseNoneFalse2655.00
282064591118NoneItem 45Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours and 70Percent lumen maintenance with CRI 80. Power Input: 220-240V at 50or60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20or22 wEach873.19873.1934.0FalseNoneNoneFalseNoneFalse29688.460
282064691118NoneItem 46Supplying and fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70Percent. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322orIEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5Percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20Percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABLorCPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.7 W, 6500KEach174.64174.641.0FalseNoneNoneFalseNoneFalse174.640
282064791118NoneItem 47Supplying and Fixing of 70-150 Watts lamp holder 2 PinEach125.08125.081.0FalseNoneNoneFalseNoneFalse125.080
282064891118NoneItem 48Supplying exhaust fan of 1440 RPM of 300mm (12 size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Each1819.561819.561.0FalseNoneNoneFalseNoneFalse1819.560
282064991118NoneItem 49Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.12" Sweep (300mmEach3536.463536.461.0FalseNoneNoneFalseNoneFalse3536.460
282065091118NoneItem 50Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm Regular modelEach2460.292460.299.0FalseNoneNoneFalseNoneFalse22142.610
282065191118NoneItem 51Fixing all types and all capacities of fluorescent or false ceiling or spot light or CFL or LED fittings indoor on the wall or ceiling or rafters or girders using 23or0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.On wall or ceiling or Rafter or GirdersEach140.42140.4234.0FalseNoneNoneFalseNoneFalse4774.280
282065291118NoneItem 52Fixing a ceiling or Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 or 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each191.16191.169.0FalseNoneNoneFalseNoneFalse1720.440
282065391118NoneItem 53Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 or 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each828.36828.362.0FalseNoneNoneFalseNoneFalse1656.720
282065491118NoneItem 54Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70Percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltageor Overload, short circuitor miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50or60Hz application. Compliance to IS 10322orIEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lmorw, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABLorCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008 . Housing with supplier word mark orname shall be Engraved or Embossing on the die cast housingor Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeorNichiaor LumiledsorOsram make LED Source. LED Streetlight 70wattsNo7026.97026.93.0FalseNoneNoneFalseNoneFalse21080.70
282065591118NoneItem 55Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts and nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories.Single bracket 1.5 Mtr. LengthEach1529.281529.283.0FalseNoneNoneFalseNoneFalse4587.840
282065691118NoneItem 56Fixing halogenormetal halide or SVL or IL or LED floodlight fitting over existing pole or wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each223.02223.023.0FalseNoneNoneFalseNoneFalse669.060
282065791118NoneItem 57LT Panel : Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSq CM0.450.4590000.0FalseNoneNoneFalseNoneFalse40500.00
282065891118NoneItem 58Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRPorDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum StripsMtr2612.522612.522.0FalseNoneNoneFalseNoneFalse5225.040
282065991118NoneItem 59Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmMtr324.5324.56.0FalseNoneNoneFalseNoneFalse1947.00
282066091118NoneItem 60Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelMtr802.4802.46.0FalseNoneNoneFalseNoneFalse4814.40
282066191118NoneItem 61Supplying and fixing Moulded Case Circuit Breaker (MCCB .over the existing woodorpanel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal MagneticorMicro processor release and Earth Fault as per IS-13947. (lcu= lcs FOUR POLE 100Amps 25kAEach9752.699752.691.0FalseNoneNoneFalseNoneFalse9752.690
282066291118NoneItem 62Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNEach2823.742823.742.0FalseNoneNoneFalseNoneFalse5647.480
282066391118NoneItem 63Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DPEach1301.541301.542.0FalseNoneNoneFalseNoneFalse2603.080
282066491118NoneItem 64Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONorOFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPEach617.14617.143.0FalseNoneNoneFalseNoneFalse1851.420
282066591118NoneItem 65Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12or24v D.CEach547.52547.522.0FalseNoneNoneFalseNoneFalse1095.040
282066691118NoneItem 66Supplying, fixing and wiring 50or5 to 400or5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape WoundEach595.9595.93.0FalseNoneNoneFalseNoneFalse1787.70
282066791118NoneItem 67Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9876.69876.61.0FalseNoneNoneFalseNoneFalse9876.60
17090199000000NoneNoneBuildingsVACCINE STORE AT KARWAR - Water Supply and Sanitary Work285691.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
282066891119NoneItem 1Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work For Sewer allround For water supply line from BW to buildingCum96.4896.4836.0FalseNoneNoneFalseNoneFalse3473.280
282066991119NoneItem 2Refilling available earth around trenchesorpipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specificationsCum161.24161.2436.0FalseNoneNoneFalseNoneFalse5804.640
282067091119NoneItem 4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm dia pipes, From Sinkm183.7183.75.0FalseNoneNoneFalseNoneFalse918.50
282067191119NoneItem 5Providing and fixing PVC pipe . OD 75mm and 6 Kgorsqcm, waste lines 75mm dia pipes, waste linesm162.56162.5615.0FalseNoneNoneFalseNoneFalse2438.40
282067291119NoneItem 6Providing and fixing PVC pipe . OD 110mm and 6 Kgorsqcm, sanitary lines 110mm dia pipes, sanitary linesm337.01337.0110.0FalseNoneNoneFalseNoneFalse3370.10
282067391119NoneItem 7Providing and fixing PVC pipe . OD 160mm,200mm and 6 Kgorsqcm, sanitary lines . 160 mm diam555.07555.07100.0FalseNoneNoneFalseNoneFalse55507.00
282067491119NoneItem 8Providing and fixing PVC pipe . OD 160mm,200mm and 6 Kgorsqcm, sanitary lines . 200 mm diam1098.251098.2510.0FalseNoneNoneFalseNoneFalse10982.50
282067591119NoneItem 9Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i) the single socketed pipes 75mm diameter 75mm RWPm233.92233.925.0FalseNoneNoneFalseNoneFalse1169.60
282067691119NoneItem 10Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter 110mm RWPm334.36334.3615.0FalseNoneNoneFalseNoneFalse5015.40
282067791119NoneItem 11Providing and fixing trap of self cleansing design with screw down or hinged grating with or wihtuot vent arm complete,including cost of cutting and making good the walls and floors 10Cms X 7.5CmsNos.627.76627.762.0FalseNoneNoneFalseNoneFalse1255.520
282067891119NoneItem 12Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover.Nos.6577.66577.610.0FalseNoneNoneFalseNoneFalse65776.00
282067991119NoneItem 13Providing 15x10cms stoneware gully trap of approved quality and make and fixing in C.C.1:2:4 and plastering with CM 1:3 wherever necessary complete. (Rate includes cost of all materials and fixtures and lead.Nos.370.05370.052.0FalseNoneNoneFalseNoneFalse740.10
282068091119NoneItem 14Sanitary and CP fixtures : Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous chinamflushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lidNos.6614.616614.611.0FalseNoneNoneFalseNoneFalse6614.610
282068191119NoneItem 15Supplying, fixing, testing and commissioning of CP health faucet consisting of: 1 No. 15mm dia CP Angle cock with wall flange. PVC flexible tube of 1.00m long tube with end nuts. Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. Make: Jaquar or equivalent.MODEL NO: ALD.CHR.565Nos.2444.962444.961.0FalseNoneNoneFalseNoneFalse2444.960
282068291119NoneItem 16Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mmNos.4703.574703.571.0FalseNoneNoneFalseNoneFalse4703.570
282068391119NoneItem 17Supplying, fixing, testing and commissioning of Sink Cock with Swinging Casted Spout (Wall Mounted Model): CON.CHR.347KN for pantry sink with CP wall flange etc. Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. ( Jaguar make or Equalent )Nos2236.142236.141.0FalseNoneNoneFalseNoneFalse2236.140
282068491119NoneItem 18Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar tapsEach3342.333342.331.0FalseNoneNoneFalseNoneFalse3342.330
282068591119NoneItem 19WATER SUPPLY : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. .15 mm diam404.4404.45.0FalseNoneNoneFalseNoneFalse2022.00
282068691119NoneItem 20Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm diam492.96492.9620.0FalseNoneNoneFalseNoneFalse9859.20
282068791119NoneItem 21Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, iorc fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm diam629.08629.0850.0FalseNoneNoneFalseNoneFalse31454.00
282068891119NoneItem 22Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.(External work)(V.2,It. No. Dwd SR 2021.22) External and Shafts and Terrace . 25mm DWSm395.16395.1630.0FalseNoneNoneFalseNoneFalse11854.80
282068991119NoneItem 23Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.l10.5710.571000.0FalseNoneNoneFalseNoneFalse10570.00
282069091119NoneItem 24Providing fixing in position nominal bore non return valve horizontal type of approved make including cost of all materials,labour and HOM with all leads complete as per specifications a) 25 mm diaNos775.78775.781.0FalseNoneNoneFalseNoneFalse775.780
282069191119NoneItem 25Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality nominal bore including cost of all materials ,labour and HOM with all leads complete as per specifications.KSRB 13.6.4.2 25mm diaNos677.98677.983.0FalseNoneNoneFalseNoneFalse2033.940
282069291119NoneItem 26Providing and construction Soak pit as per IS 24701 P1and II and relevant construction drawing. The pit shall be construction of RCC Rings with RCC top slab and PCC bed at bottom and Recharge pit Filling of 40mm jelly and sandSize of (SOAK pit:. 1.2m dia x 3.0mdepth)Nos23719.1823719.181.0FalseNoneNoneFalseNoneFalse23719.180
282069391119NoneItem 27Supplying, installing, testing and commissioning approved make submersible pump made of C.I Construction suitable for building application. (Submersible Single phase 4 inchor100mm,1HP)Nos17610.3217610.321.0FalseNoneNoneFalseNoneFalse17610.320
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17090199020000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17090199020000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17090199020001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17090201140000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17090201260000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17090201380000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17090201470000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17090201600000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17090201710000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17090201870000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17090201980000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17090202060000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17090202170000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17090202260000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17090202350000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17090202450000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17090202550000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17090202630000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17090202710000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17090202810000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17090202900000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17090203010000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17090203730000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2022-23None
17090203840000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
17090203960000NoneNoneELIGIBILITYThe Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b)(c)(d)and (e).None
17090204050000NoneNoneELIGIBILITYAs per GO No:FD-CAM/16/2022 (P-2) dated 22nd August 2022 , Banker Certificate / Line of credit shall be uploaded in the format mentioned in the SECTION -11 as per bid documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract, each tenderer in its name should have in the last five years i.e. (2018-2019 to 2022-2023) achieved in at least two financial years a minimum financial turnover (in all classes of civil engineering construction works only) of Rs. 79.58 lakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneMandating Satisfactorily completed, at least one work of value not less than Rs. 39.79 Lakhs as a prime contractorPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe contractor should have executed the following minimum quantities of work in any one financial year. 1 PCC & RCC 114.00 Cum 2 TMT steel 11446.00 Kg 3 CC Block Masonry 405.00 Sqm 4 M S Grill 590.00 Kg 5 Plastering 1076.00 Sqm 6 Painting 1076.00 Sqm 7 Flooring 134.00 Sqm 8 WPC 176.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/Government Electrical Inspectorate and should have executed similar building electrical works totaling Rs. 2.20 Lakhs in any one financial year Note:Consent letter of the subcontractor should be uploadedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/KUWS&DB and should possess valid licence for executing water supply or sanitary engineering works issued by competent authority and should have executed similar water supply or sanitary engineering works total Rs. 1.40 Lakh in any one financial year, Note:Consent letter of the sub contractor should be uploadedPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNonePWD Registration Certificate Class III & aboveCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PWD Registration certificate
NoneNoneNoneNoneSite Engineer B.E. Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings : 1 NoCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneLiquid assets and/or availability of credit facilities of no less than Rs. 23.90 Lakhs (Credit lines/letter of credit/certificates from banks for meeting the fund requirement etc.,)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
PWD Registration Certificate -Class III & aboveTrueTechnical Bid
GST RegistrationTrueTechnical Bid
Work done certificateTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone