createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709537209148
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd537300.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose13-03-2024 17:30:00
tenderQueryClose11-03-2024 12:00:00
technicalBidOpen15-03-2024 10:30:00
publishedDate04-03-2024 14:34:00
publishedByPostPWD_EE_DIV_UDP
publishedByUserKPE10086 - DINESH K N
bidValidityPeriod90
noOfCalls2
preBidMeetingDate11-03-2024 16:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonShanthala.J.G
splitEmdRequiredYnTrue
emdBankGuarantee437300.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08202531802
mobileNumber7019413273
tenderSupplierListNone
tenderSchedule
createdTs1709537209151
version20
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT7742/CALL-2
titleConstruction of Government Industrial Training Institute Building at Karkala in Udupi District
descriptionConstruction of Government Industrial Training Institute Building at Karkala in Udupi District
categoryWORKS
categoryTextWorks
ecv30354557.49
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location1698
locationNamePWD Division Office Udupi
provisionalAmount37100000.0
groupOverheadTotal0.0
fileNumberPWD/KARKALA/ITI/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17095372090001NoneNoneBuildingsConstruction of Government Industrial Training Institute Building at Karkala in Udupi District - Ground Floor A Block10677533.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
290098695238None1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m (S.R.I.No. 1.16.1. P.9, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum620.48620.48727.12FalseNoneNoneFalseNoneFalse451163.41760
290098795238None1.4.1 Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (S.R.I.No. 1.4.1 P.5 Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum271.04271.0460.79FalseNoneNoneFalseNoneFalse16476.52160
290098895238None17-C.2Providing and fixing in position 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 600 mm. Long and at 300 mm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating. (S.R.I.No. 17-C.2 P.163 Vol-3 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No425.6425.6478.0FalseNoneNoneFalseNoneFalse203436.80
290098995238None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.1.3, P.15, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum6707.686707.68140.12FalseNoneNoneFalseNoneFalse939880.12160
290099095238None2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately). "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.2.3, P.15, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum7664.037664.03127.23FalseNoneNoneFalseNoneFalse975094.53690
290099195238None2.4.3 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.4.3 P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum10644.4810644.4823.98FalseNoneNoneFalseNoneFalse255254.63040
290099295238None1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundationsand other similar works etc. in layers not exceeding 20cm in depth, consolidatingeach deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( Volume-1 Page No:- 7 Item No:- 1.11) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum484.96484.96539.11FalseNoneNoneFalseNoneFalse261446.78560
290099395238None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2, P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum13029.0713029.0713.54FalseNoneNoneFalseNoneFalse176413.60780
290099495238None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2 P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12262.6612262.6643.64FalseNoneNoneFalseNoneFalse535142.48240
290099595238None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2 P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.2484.03FalseNoneNoneFalseNoneFalse966029.04720
290099695238None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2 P.17, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11113.0311113.032.47FalseNoneNoneFalseNoneFalse27449.18410
290099795238None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings (S.R.I.No.2.11.a, P.18, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t100191.84100191.8425.71FalseNoneNoneFalseNoneFalse2575932.20640
290099895238None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, Vol - 2, page 17 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1467.21467.2328.02FalseNoneNoneFalseNoneFalse481270.9440
290099995238None12.83.1Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 48x40 mm PVC Extruded section (S.R.I.No.12.83.1, P.108, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m221.76221.7615.3FalseNoneNoneFalseNoneFalse3392.9280
290100095238None12.96Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame (S.R.I.No.12.96, P.112, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m720.16720.1636.3FalseNoneNoneFalseNoneFalse26141.8080
290100195238None12.92 Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T Ps shall not be made) (S.R.I.No.12.92 P.111, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm6994.46994.415.75FalseNoneNoneFalseNoneFalse110161.80
290100295238None12.97.1 Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness (S.R.I.No.12.97.1 P.112, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm3588.483588.485.67FalseNoneNoneFalseNoneFalse20346.68160
290100395238None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (S.R.I.No.11.34B, P.86, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Kg204.96204.961530.27FalseNoneNoneFalseNoneFalse313644.13920
290100495238None12.90Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (S.R.I.No.12.90, P.110, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm7542.087542.0872.87FalseNoneNoneFalseNoneFalse549591.36960
290100595238None9.17.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (S.R.I.No. 9.17.2 P.61, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1316.01316.0452.13FalseNoneNoneFalseNoneFalse595003.080
290100695238None9.10 Providing and fixing 1st quality ceramic glazed floor tiles conforming toIS : 15622 (thickness to be specified by the manufacturer ) of approvedmake in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dadosover 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand)and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. (S.R.I.No. 9.10 P.60, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1238.721238.7214.8FalseNoneNoneFalseNoneFalse18333.0560
290100795238None9.23 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (S.R.I.No. 9.23 P.63, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm2761.922761.9242.9FalseNoneNoneFalseNoneFalse118486.3680
290100895238None9.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (S.R.I.No. 9.38 P.65, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1559.041559.0476.02FalseNoneNoneFalseNoneFalse118518.22080
290100995238None8.7Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No.8.7, P.42, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm409.92409.92704.26FalseNoneNoneFalseNoneFalse288690.25920
290101095238None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No.8.8, P.42, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm415.52415.52434.0FalseNoneNoneFalseNoneFalse180335.680
290101195238None8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (S.R.I.No.8.51 P.50, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm112.0112.01170.91FalseNoneNoneFalseNoneFalse131141.920
290101295238None11.28 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (S.R.I.No. 11.28 P.85, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Kg632.8632.8140.4FalseNoneNoneFalseNoneFalse88845.120
290101395238None8.33.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No. 8.33.1 P.46, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm176.96176.96704.26FalseNoneNoneFalseNoneFalse124625.84960
290101495238None8.30 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No. 8.30 P.46, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm194.88194.88434.0FalseNoneNoneFalseNoneFalse84577.920
290101595238None8.33.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No. 8.33.3 P.47, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm155.68155.6872.87FalseNoneNoneFalseNoneFalse11344.40160
290101695238None12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (S.R.I.No.12.58, P.105, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No134.4134.454.0FalseNoneNoneFalseNoneFalse7257.60
290101795238None12.76.1Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (S.R.I.No.12.76.1, P.107, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No487.2487.218.0FalseNoneNoneFalseNoneFalse8769.60
290101895238None12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) (S.R.I.No.12.75.1, P.107, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No308.0308.027.0FalseNoneNoneFalseNoneFalse8316.00
290101995238None12.79.1 Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm (S.R.I.No.12.79.1 P.108, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No278.88278.8818.0FalseNoneNoneFalseNoneFalse5019.840
17095372090001NoneNoneBuildingsConstruction of Government Industrial Training Institute Building at Karkala in Udupi District - First Floor A Block638278.67
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
290102095239None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, Vol - 1, page 16 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum13159.3613159.367.24FalseNoneNoneFalseNoneFalse95273.76640
290102195239None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings (S.R.I.No.2.11.a, P.18, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t101193.76101193.760.58FalseNoneNoneFalseNoneFalse58692.38080
290102295239None15.1 Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (S.R.I.No. 15.1 P.149, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm924.19924.19524.04FalseNoneNoneFalseNoneFalse484312.52760
17095372090001NoneNoneBuildingsConstruction of Government Industrial Training Institute Building at Karkala in Udupi District - Ground Floor B Block14824641.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
290102395240None1.16.1Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m (S.R.I.No. 1.16.1. P.9, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum620.48620.481011.49FalseNoneNoneFalseNoneFalse627609.31520
290102495240None1.4.1 Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m (S.R.I.No. 1.4.1 P.5 Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum271.04271.04119.74FalseNoneNoneFalseNoneFalse32454.32960
290102595240None17-C.2Providing and fixing in position 25mm dia dowel bars precoated with anticorrosive epoxy paint of required Dia. 600 mm. Long and at 300 mm. C/C and wherever directed including handling, straightening, necessary cutting supported by TMT FE 500, chairs with proper alignment by using properly designed assembly of Bulkheads lubricating (S.R.I.No. 17-C.2 P.163 Vol-3 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No425.6425.6504.0FalseNoneNoneFalseNoneFalse214502.40
290102695240None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) "Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.1.3, P.15, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum6707.686707.68190.27FalseNoneNoneFalseNoneFalse1276270.27360
290102795240None2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.2.3, P.15, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum7664.037664.03118.79FalseNoneNoneFalseNoneFalse910410.12370
290102895240None2.4.3 Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.4.3 P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum10644.4810644.4834.65FalseNoneNoneFalseNoneFalse368831.2320
290102995240None1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundationsand other similar works etc. in layers not exceeding 20cm in depth, consolidatingeach deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( Volume-1 Page No:- 7 Item No:- 1.11) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum484.96484.96775.44FalseNoneNoneFalseNoneFalse376057.38240
290103095240None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2, P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum8430.588430.5822.06FalseNoneNoneFalseNoneFalse185978.59480
290103195240None2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2 P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum12262.6612262.6656.52FalseNoneNoneFalseNoneFalse693085.54320
290103295240None2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2 P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.24197.01FalseNoneNoneFalseNoneFalse2264874.24240
290103395240None2.5.2 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2 P.17, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum10046.0610046.067.08FalseNoneNoneFalseNoneFalse71126.10480
290103495240None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings (S.R.I.No.2.11.a, P.18, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t100191.84100191.8434.07FalseNoneNoneFalseNoneFalse3413535.98880
290103595240None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, Vol - 2, page 17 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1467.21467.2501.6FalseNoneNoneFalseNoneFalse735947.520
290103695240None12.83.1Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 48x40 mm PVC Extruded section (S.R.I.No.12.83.1, P.108, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m221.76221.7645.9FalseNoneNoneFalseNoneFalse10178.7840
290103795240None12.96Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame (S.R.I.No.12.96, P.112, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m720.16720.166.05FalseNoneNoneFalseNoneFalse4356.9680
290103895240None12.97.1 Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames. 30 mm thickness (S.R.I.No.12.97.1 P.112, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm3588.483588.4817.01FalseNoneNoneFalseNoneFalse61040.04480
290103995240None12.92 Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (S.R.I.No.12.92 P.111, Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm6994.46994.42.62FalseNoneNoneFalseNoneFalse18325.3280
290104095240None11.6.2 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (S.R.I.No.11.6.2 P.78 Vol-2, PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm2803.362803.3651.3FalseNoneNoneFalseNoneFalse143812.3680
290104195240None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (S.R.I.No.11.34B, P.86, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Kg204.96204.962577.33FalseNoneNoneFalseNoneFalse528249.55680
290104295240None12.90Providing & fixing of 3track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (S.R.I.No.12.90, P.110, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm7542.087542.08122.73FalseNoneNoneFalseNoneFalse925639.47840
290104395240None9.1 Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete (S.R.I.No. 9.1 P.59, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm505.12505.12700.31FalseNoneNoneFalseNoneFalse353740.58720
290104495240None9.9 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (S.R.I.No. 9.9 P.60, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1205.121205.1251.04FalseNoneNoneFalseNoneFalse61509.32480
290104595240None9.38 Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (S.R.I.No. 9.38 P.65, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1559.041559.04131.27FalseNoneNoneFalseNoneFalse204655.18080
290104695240None8.7Providing 15 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No.8.7, P.42, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm409.92409.921025.78FalseNoneNoneFalseNoneFalse420487.73760
290104795240None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No.8.8, P.42, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm415.52415.52669.91FalseNoneNoneFalseNoneFalse278361.00320
290104895240None8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (S.R.I.No.8.51 P.50, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm112.0112.01783.09FalseNoneNoneFalseNoneFalse199706.080
290104995240None11.28 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (S.R.I.No. 11.28 P.85, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Kg632.8632.8140.4FalseNoneNoneFalseNoneFalse88845.120
290105095240None8.33.1 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No. 8.33.1 P.46, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm176.96176.961025.78FalseNoneNoneFalseNoneFalse181522.02880
290105195240None8.32 Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No. 8.32 P.46, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm174.72174.72670.06FalseNoneNoneFalseNoneFalse117072.88320
290105295240None8.33.3 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No. 8.33.3 P.47, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm155.68155.68174.03FalseNoneNoneFalseNoneFalse27092.99040
290105395240None12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. (S.R.I.No.12.58, P.105, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No134.4134.454.0FalseNoneNoneFalseNoneFalse7257.60
290105495240None12.76.1Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250 x 10mm (S.R.I.No.12.76.1, P.107, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No487.2487.218.0FalseNoneNoneFalseNoneFalse8769.60
290105595240None12.75.1Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) (S.R.I.No.12.75.1, P.107, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No308.0308.027.0FalseNoneNoneFalseNoneFalse8316.00
290105695240None12.79.1 Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm (S.R.I.No.12.79.1 P.108, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No278.88278.8818.0FalseNoneNoneFalseNoneFalse5019.840
17095372090001NoneNoneBuildingsConstruction of Government Industrial Training Institute Building at Karkala in Udupi District - First Floor B Block1038594.84
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
290105795241None2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.5.2, Vol - 1, page 16 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum13159.3613159.369.73FalseNoneNoneFalseNoneFalse128040.57280
290105895241None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings (S.R.I.No.2.11.a, P.18, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t101193.76101193.760.78FalseNoneNoneFalseNoneFalse78931.13280
290105995241None15.1 Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (S.R.I.No. 15.1 P.149, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm924.19924.19899.84FalseNoneNoneFalseNoneFalse831623.12960
17095372100001NoneNoneBuildingsConstruction of Government Industrial Training Institute Building at Karkala in Udupi District - Sanitary and water supply works973081.37
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
290106095242None1.14.1 Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m (S.R.I.No. 1.14.1 P.8, PWD Common SR Volume-1 for the year PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum114.24114.24294.4FalseNoneNoneFalseNoneFalse33632.2560
290106195242None2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (S.R.I.No.2.1.3, P.15, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t6707.686707.6815.6FalseNoneNoneFalseNoneFalse104639.8080
290106295242None6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (S.R.I.No.6.32, Vol - 2, page 17 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm1467.21467.235.55FalseNoneNoneFalseNoneFalse52158.960
290106395242None8.1.2Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (S.R.I.No.8.1.2, P.41, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sqm269.92269.92285.36FalseNoneNoneFalseNoneFalse77024.37120
290106495242None1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ( Volume-1 Page No:- 6 Item No:- 1.10) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum179.2179.230.0FalseNoneNoneFalseNoneFalse5376.00
290106595242None2.11.aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings (S.R.I.No.2.11.a, P.18, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.t100191.84100191.840.64FalseNoneNoneFalseNoneFalse64122.77760
290106695242None2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) "M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" (S.R.I.No.2.5.2, P.16, Vol-1 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Cum11496.2411496.2413.98FalseNoneNoneFalseNoneFalse160717.43520
290106795242None16.9 Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (S.R.I.No. 16.9 , P.191, Vol-5 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each6108.486108.485.0FalseNoneNoneFalseNoneFalse30542.40
290106895242None16.7.2Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 32mm nominal bore pipes (S.R.I.No.16.7.2, P.191, Vol-5 RWS SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m79.5279.52300.0FalseNoneNoneFalseNoneFalse23856.00
290106995242None16.7.3Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 40mm nominal bore pipes (S.R.I.No.16.7.3, P.191, Vol-5 RWS SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m98.5698.56135.0FalseNoneNoneFalseNoneFalse13305.60
290107095242None16.7.4Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes (S.R.I.No.16.7.4, P.191, Vol-5 RWS SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m155.68155.68120.0FalseNoneNoneFalseNoneFalse18681.60
290107195242None13.34 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (S.R.I.No.13.34 P.123, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Ltr10.0810.082000.0FalseNoneNoneFalseNoneFalse20160.00
290107295242None13.2.2 Providing and fixing brass bib cock of approved quality : 20mm nominal bore (S.R.I.No.13.2.2 P.117, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No341.6341.612.0FalseNoneNoneFalseNoneFalse4099.20
290107395242None13.3.2 Providing and fixing brass bib stop of approved quality : 20mm nominal bore (S.R.I.No.13.3.2 P.117, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No341.6341.612.0FalseNoneNoneFalseNoneFalse4099.20
290107495242None13.4.2 Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore (S.R.I.No.13.4.2 P.117, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No669.76669.7610.0FalseNoneNoneFalseNoneFalse6697.60
290107595242None14.7.2 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (S.R.I.No.14.7.2 P.132, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No2868.322868.3215.0FalseNoneNoneFalseNoneFalse43024.80
290107695242None14.2.1 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (S.R.I.No.14.2.1 P.131, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No5418.565418.562.0FalseNoneNoneFalseNoneFalse10837.120
290107795242None14.4.1 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushing cistern (S.R.I.No.14.4.1 P.131, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No4988.484988.484.0FalseNoneNoneFalseNoneFalse19953.920
290107895242None14.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (S.R.I.No.14.31 P.136, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1366.41366.44.0FalseNoneNoneFalseNoneFalse5465.60
290107995242None14.16A Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (S.R.I.No.14.16A P.134, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No304.64304.6414.0FalseNoneNoneFalseNoneFalse4264.960
290108095242None14.22A Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (S.R.I.No.14.22A P.135, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No907.2907.214.0FalseNoneNoneFalseNoneFalse12700.80
290108195242None14.40.1 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g. (S.R.I.No.14.40.1 P.137, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No535.36535.364.0FalseNoneNoneFalseNoneFalse2141.440
290108295242None14.29 Providing and fixing 100 mm sand cast Iron grating for gully trap. (S.R.I.No.14.29 P.136, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No52.6452.6412.0FalseNoneNoneFalseNoneFalse631.680
290108395242None13.31.6 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 50 mm nominal dia Pipes (S.R.I.No.13.31.6 P.122, Vol-2 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m874.72874.7272.0FalseNoneNoneFalseNoneFalse62979.840
290108495242None10.14.5Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 140mm(weight of pipe -2.131 kg) (S.R.I.No.10.14.5, P.120 Vol-5 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m445.76445.76335.0FalseNoneNoneFalseNoneFalse149329.60
290108595242None10.14.4Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete.110mm(weight of pipe -1.315 kg) (S.R.I.No.10.14.4, P.120 Vol-5 PWD SR 2023-24) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m315.84315.84135.0FalseNoneNoneFalseNoneFalse42638.40
17095372100000NoneNoneBuildingsDetailed Sub Estimate for Providing to Govt. Industrial Training Institute Building at Karkala Town, Udupi District2202427.13
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
290108695243None1.2.1Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 19/20mm dia 2mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m73.9273.92450.0FalseNoneNoneFalseNoneFalse33264.00
290108795243None1.2.2Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )" 25mm dia 2mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m87.3687.36670.0FalseNoneNoneFalseNoneFalse58531.20
290108895243None1.2.3Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) )" 32 mm dia 2.5 mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m115.36115.36250.0FalseNoneNoneFalseNoneFalse28840.00
290108995243None1.3.1Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 19/20mm dia 2mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m76.1676.16760.0FalseNoneNoneFalseNoneFalse57881.60
290109095243None1.3.2Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 25mm dia 2mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m88.4888.48600.0FalseNoneNoneFalseNoneFalse53088.00
290109195243None1.3.3Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 32mm dia 2.5mm thick ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m110.88110.8870.0FalseNoneNoneFalseNoneFalse7761.60
290109295243None1.5.1Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 19/20 mm deep Junction box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each54.8854.8890.0FalseNoneNoneFalseNoneFalse4939.20
290109395243None1.5.2Supplying and fixing PVC/metal conduit Deep junction box. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 25 mm deep Junction box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each62.7262.7295.0FalseNoneNoneFalseNoneFalse5958.40
290109495243None1.13Supplying And Fixing Metal Fan Box with Round Hook.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No131.04131.0474.0FalseNoneNoneFalseNoneFalse9696.960
290109595243None5.18.11Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.-111-Double Door,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Way TP & N ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each4522.564522.567.0FalseNoneNoneFalseNoneFalse31657.920
290109695243None3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 1-2 Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each154.56154.5660.0FalseNoneNoneFalseNoneFalse9273.60
290109795243None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4-5Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each198.24198.2460.0FalseNoneNoneFalseNoneFalse11894.40
290109895243None3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 6Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each246.4246.420.0FalseNoneNoneFalseNoneFalse4928.00
290109995243None3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 8Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each292.32292.3270.0FalseNoneNoneFalseNoneFalse20462.40
290110095243None3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall ,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 10-12Way ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each357.28357.2850.0FalseNoneNoneFalseNoneFalse17864.00
290110195243None3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 1-2 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each153.44153.4490.0FalseNoneNoneFalseNoneFalse13809.60
290110295243None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 4 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each180.32180.3280.0FalseNoneNoneFalseNoneFalse14425.60
290110395243None3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 6 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each262.08262.0820.0FalseNoneNoneFalseNoneFalse5241.60
290110495243None3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 8 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each318.08318.08100.0FalseNoneNoneFalseNoneFalse31808.00
290110595243None3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 10-12 Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each385.28385.2850.0FalseNoneNoneFalseNoneFalse19264.00
290110695243None2.2.1Wires and Cables-Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Short point upto 3Mtr from tapping point to out let via switch box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Point301.28301.2855.0FalseNoneNoneFalseNoneFalse16570.40
290110795243None2.2.2Wires and Cables-Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Point424.48424.4870.0FalseNoneNoneFalseNoneFalse29713.60
290110895243None2.2.3Wires and Cables-Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Point621.6621.691.0FalseNoneNoneFalseNoneFalse56565.60
290110995243None3.6.1Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6Amps one way Switch ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each114.24114.24276.0FalseNoneNoneFalseNoneFalse31530.240
290111095243None3.6.3Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6Amps 3way socket ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each191.52191.52220.0FalseNoneNoneFalseNoneFalse42134.40
290111195243None3.6.4Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )Stepped Fan Regulator Two Module ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each399.84399.8474.0FalseNoneNoneFalseNoneFalse29588.160
290111295243None3.6.8Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6Amps Bell push ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each198.24198.249.0FalseNoneNoneFalseNoneFalse1784.160
290111395243None3.6.9Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )32Amps DP switch ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each365.12365.1290.0FalseNoneNoneFalseNoneFalse32860.80
290111495243None3.6.10Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Is 3854 and IS 1293.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6/16Amps universal socket ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each264.32264.3250.0FalseNoneNoneFalseNoneFalse13216.00
290111595243None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 1.5 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m29.1229.122500.0FalseNoneNoneFalseNoneFalse72800.00
290111695243None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )2.5 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m47.0447.042500.0FalseNoneNoneFalseNoneFalse117600.00
290111795243None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )4 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m70.5670.562320.0FalseNoneNoneFalseNoneFalse163699.20
290111895243None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical )6 sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m103.04103.04630.0FalseNoneNoneFalseNoneFalse64915.20
290111995243None5.12.3CONTROL SWITCH GEARS & ACCESSORIES Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 125 A ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each13802.8813802.881.0FalseNoneNoneFalseNoneFalse13802.880
290112095243None13.8.5Fixing of . A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100A to 250A TPDT/COS ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each527.52527.521.0FalseNoneNoneFalseNoneFalse527.520
290112195243None5.11.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.-FOUR Pole,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 100Amps 25kA. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each9438.249438.243.0FalseNoneNoneFalseNoneFalse28314.720
290112295243None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 6-32 Amps DP ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each827.68827.6850.0FalseNoneNoneFalseNoneFalse41384.00
290112395243None5.18.5Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) 40Amps TPN ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each3409.283409.2814.0FalseNoneNoneFalseNoneFalse47729.920
290112495243None5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/ flush mounting on panel board,( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each10365.610365.61.0FalseNoneNoneFalseNoneFalse10365.60
290112595243None5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each10432.810432.81.0FalseNoneNoneFalseNoneFalse10432.80
290112695243None5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C. ( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each576.8576.82.0FalseNoneNoneFalseNoneFalse1153.60
290112795243None5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each629.44629.446.0FalseNoneNoneFalseNoneFalse3776.640
290112895243None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 16SWG ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Sq CM0.480.48100000.0FalseNoneNoneFalseNoneFalse48000.00
290112995243None5.40.1Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 100Amps 4x30x6mm Aluminium Strips ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m2760.82760.82.0FalseNoneNoneFalseNoneFalse5521.60
290113095243None5.41.2Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 50x50x6mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m442.4442.48.0FalseNoneNoneFalseNoneFalse3539.20
290113195243None11.3.2Supplying of .feet PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part III , Utilization ( PWD Electrical ) ) LED light fighting 1 x4 20/22 w ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each772.8772.8106.0FalseNoneNoneFalseNoneFalse81916.80
290113295243None11.11.4Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 9 W , 6500 K ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each172.48172.4814.0FalseNoneNoneFalseNoneFalse2414.720
290113395243None11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with . W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) LED square or round down light 10-12W,GROUND FLOOR- Block- A,corridor. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each991.2991.25.0FalseNoneNoneFalseNoneFalse4956.00
290113495243None11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuserwith Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) LED Streetlight 70W, ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each6632.646632.648.0FalseNoneNoneFalseNoneFalse53061.120
290113595243None6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1671.041671.047.0FalseNoneNoneFalseNoneFalse11697.280
290113695243None6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 , Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10 RPM, Rated air delivery 210 +/- 10 Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 48" Sweep 5 Star (1200mm) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each2998.242998.2447.0FalseNoneNoneFalseNoneFalse140917.280
290113795243None13.2.2Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) Using 32mm dia G.I.Pipe ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each1450.41450.48.0FalseNoneNoneFalseNoneFalse11603.20
290113895243None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) On wall / ceiling / Rafter / Girders ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each136.64136.64111.0FalseNoneNoneFalseNoneFalse15167.040
290113995243None13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each352.8352.847.0FalseNoneNoneFalseNoneFalse16581.60
290114095243None13.12Extra length of GI pipe of class B 19mm dia for down rod.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each220.64220.6447.0FalseNoneNoneFalseNoneFalse10370.080
290114195243None13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each791.84791.847.0FalseNoneNoneFalseNoneFalse5542.880
290114295243None5.6.4Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 12" x 12" x 2" ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each202.72202.7230.0FalseNoneNoneFalseNoneFalse6081.60
290114395243None5.31Supplying and fixing Electronic Trivector Meter (ETV) suitable for operation LT operation and -CT operated meter in polycarbonate body in class 0.5 accuracy as per IS 14697 and completely wired.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each4916.84916.82.0FalseNoneNoneFalseNoneFalse9833.60
290114495243None5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each629.44629.442.0FalseNoneNoneFalseNoneFalse1258.880
290114595243None015Grounding of Towers/Equipments a) Grounding of towers including cost of 40mm dia 2.5 mm thick, class C G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges.( COMMON Electrical SR of 2023-24, BESCOMPART II,Rates for Labour of Major Works ) Maerial cost Rs. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set5850.885850.884.0FalseNoneNoneFalseNoneFalse23403.520
290114695243None015Grounding of Towers/Equipments a) Grounding of towers including cost of 40mm dia 2.5 mm thick, class C G.I. Pipe of 3 Mtrs length as per specifications, with 50X6 mm GI Flats 3 Mtr long, salt charcoal, including excavation charges.( COMMON Electrical SR of 2023-24, BESCOMPART II,Rates for Labour of Major Works ) Labour charges Rs, ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km2364.322364.324.0FalseNoneNoneFalseNoneFalse9457.280
290114795243None167 bGrounding of equipment with 50 x 6 mm G.I. Flat and connecting equipment to theearthmat/ground pit. Each point of earthing with all formation works like bending, twisting, drilling of holes and connecting by welding (inclusive of all T&P and consumables) to the earthmat/ground pit/point of earth connection, all thematerials supplied by the contractor.( COMMON Electrical SR of 2023-24, BESCOM-PART -II,Rates for Labour of Major Works ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Rmtr375.2375.240.0FalseNoneNoneFalseNoneFalse15008.00
290114895243None32.13Supplying of 1.1 KV ,XLPE or Heat reisistant PVC insulated , PVC extrusted inner seath Armored , LTUG Cable as per IS-1554 ( Part-1) or IS-7098 Part-1 Armouring strip thickness and resistively as per IS-3975,.( COMMON Electrical SR of 2023-24, BESCOMStandard Stock Materials( 11 KV System ) ) 70 Sqmm, 3.5 Core, (18 GI Strips - 4 x 0.8 mm) Materials cost Rs. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km356061.44356061.440.15FalseNoneNoneFalseNoneFalse53409.2160
290114995243None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 ) In all kinds of soils. Depth upto 1.50m Ic, 120 x 0.60 x 0.60 = 43.20 cmt ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.cm542.08542.0843.2FalseNoneNoneFalseNoneFalse23417.8560
290115095243None1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications.( COMMON Electrical SR of 2023-24, PWD CIVIL SR CHAPTER-1 ) In Hard Soil. Ic, 120 x 0.60 x 0.60 = 43.20 cmt Labour charges Rs, ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.cm179.2179.243.0FalseNoneNoneFalseNoneFalse7705.60
290115195243None21.06Laying of cable in existing Trench / GI Pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminium Rollers as directed by the departmental staff,. LT Cable -35 to 95 Sqmm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km34875.6834875.680.15FalseNoneNoneFalseNoneFalse5231.3520
290115295243None448.07GI Pipe B-Class as per IS 1239 GI Pipe -65 mm Dia ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.m519.68519.6810.0FalseNoneNoneFalseNoneFalse5196.80
290115395243None63.04Supplying of Cable gland ,.( COMMON Electrical SR of 2023-24, Part - III , Utilization ( PWD Electrical ) ) 45mm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No220.64220.644.0FalseNoneNoneFalseNoneFalse882.560
290115495243None59.02Supplying of Haevy Duty Copper Terminal Long Barrel,. 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No44.844.84.0FalseNoneNoneFalseNoneFalse179.20
290115595243None59.04Supplying of Haevy Duty Copper Terminal Long Barrel,.70 Sqmm Copper Terminal, Apprx Wt: 38 Gm ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No99.6899.686.0FalseNoneNoneFalseNoneFalse598.080
290115695243None12.04Supplying of Distribution Transformer- Phase, 11 KV / 433 Volts, Stacked CRGO Core with Oil.( COMMON Electrical SR 2022-22 ) A. OPEN BUSHING TYPE. D) 63 kVA,Aluminium Wdg. Star 2 ( 5 Star) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No204450.4204450.41.0FalseNoneNoneFalseNoneFalse204450.40
290115795243None1 b)Line Supports ( Pole) RCC Pole - 9 Mtr Long, 145 Kg WL.( Dwg No. BESCOM / GM /QS&S /02 Dated 24.11.2028) as per IS-785 ) ( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No7925.127925.122.0FalseNoneNoneFalseNoneFalse15850.240
290115895243None21.04Spplying and errection of Double pole Transformer Structure conplete with cross arms , braces, clamps, bolts 7 nuts and washers including 2 Nos of poles.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) For 25 /63 / 100 KVA 4/5 Star Rated Transformer on RCC Pole- 9Mtr Long , 145 Kg WL -GI.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No26951.6826951.681.0FalseNoneNoneFalseNoneFalse26951.680
290115995243None2.02Cross Arms ( MS & GI ) as per IS-1977.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) 11 kV Horizontal cross arm with Galvanized Iron ( GI) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1289.121289.122.0FalseNoneNoneFalseNoneFalse2578.240
290116095243None2.04Cross Arms ( MS & GI ) as per IS-1977.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) 11 KV Special 3 Pin Cross Arm-GI ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No323.68323.681.0FalseNoneNoneFalseNoneFalse323.680
290116195243None2.06Cross Arms ( MS & GI ) as per IS-1977.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) 4 Pin Cross Arm- GI ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No424.48424.481.0FalseNoneNoneFalseNoneFalse424.480
290116295243None2.10Cross Arms ( MS & GI ) as per IS-1977.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ltst Support 50x6 Flat-GI ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No91.8491.841.0FalseNoneNoneFalseNoneFalse91.840
290116395243None2.12Cross Arms ( MS & GI ) as per IS-1977.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) HTST Support 50 x 8 mm Flat -GI ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No135.52135.521.0FalseNoneNoneFalseNoneFalse135.520
290116495243None2.16Cross Arms ( MS & GI ) as per IS-1977.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) Spiral Earth Electrode ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No267.68267.681.0FalseNoneNoneFalseNoneFalse267.680
290116595243None6.01Insulator as per IS- 1445 for Ceramic, IS-7935 for GI Pin ,IEC -61109 for Polymeric.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) 11 KV Ceramic Pin Insulator ( Shell only) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No92.9692.969.0FalseNoneNoneFalseNoneFalse836.640
290116695243None6.10Insulator as per IS- 1445 for Ceramic, IS-7935 for GI Pin ,IEC -61109 for Polymeric.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) 11KV , 45 KN Polymeric Insulator ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No208.32208.323.0FalseNoneNoneFalseNoneFalse624.960
290116795243None7.02ACSR Conductor as per IS- 398 ( Part- 2/1996) Rabbit ACSR Conductor ( 6/3.35 mm Al+ 1/3.35 St) Sted Wl. 214 Kg / KM( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Km51782.0851782.080.3FalseNoneNoneFalseNoneFalse15534.6240
290116895243None24.01GOS as per IS- 9921 , is -1977 11 KV , 200 Amps Single Break GOS ( Dwg No, 200 Amps Single Break GOS ( Dwg No.BESCOM / GM /QS&S /23 Dtd 24.11.2018 0( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set10584.010584.01.0FalseNoneNoneFalseNoneFalse10584.00
290116995243None25.01DOLO Cut out as per IS-9385 , Part -1 to 3 11 KV ,DOLO Cut out Conventional to Erst while KEB Specification.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set6580.06580.01.0FalseNoneNoneFalseNoneFalse6580.00
290117095243None17.01L T Protection Kit LT Protection Kit ( Dwg No. BESCOM/GM/QS&S/10 Dated 24.11.2018)( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No2265.762265.761.0FalseNoneNoneFalseNoneFalse2265.760
290117195243None18.01LT Distribution Box as per IS-13947 Part-1 & 2. LT Distribution Box for 100 KVA DTC with MCCB'S ( Sheet metal).( Dwg No. BESCOM/GM/QS&S/58 Dated 24.11.2018))( COMMON Electrical SR BESCOM 2023-24, Labour -11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No25408.3225408.321.0FalseNoneNoneFalseNoneFalse25408.320
290117295243None19.019 KV , 5 KA Lightning Arrestor Metal Oxide Ceramic type with Ground Disconnector.( Dwg No. BESCOM/GM/QS&S/26 Dated 24.11.2018)( COMMON Electrical SR BESCOM 2023-24, Labour -11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1030.41030.43.0FalseNoneNoneFalseNoneFalse3091.20
290117395243None20.0111 kv , HG Fuse Unit with Solid Core Insulator.( Dwg No. BESCOM/GM/QS&S/21 Dated 24.11.2018))( COMMON Electrical SR BESCOM 2023-24, Labour -11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1197.281197.283.0FalseNoneNoneFalseNoneFalse3591.840
290117495243None21.04Double pole TC Set for Errection of Transformer on RCC /PSCC 9 Mtr Long Poles as per IS-1977.)( COMMON Electrical SR BESCOM 2023-24, Labour -11 KV System ) ) For 25/63/100 KVA 4/5 Star Rated Transformer on RCC Pole-9Mtr Long.( COMMON Electrical SR BESCOM 2023-24, 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No26951.6826951.681.0FalseNoneNoneFalseNoneFalse26951.680
290117595243None2.02Errection of RCC /PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr Depth.( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1246.561246.562.0FalseNoneNoneFalseNoneFalse2493.120
290117695243None3.01Errection of Double Pole Transformer Structure using 9 mtr Long RCC ( 145 Kg WL) /PSCC ( 300 Kg WL) Pole including fixing of structure Materials , Errection of poles etc., complete for mounting of Transformer as per approved drawing.( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) For 25/63/100 KVA. ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Per Structure6412.06412.01.0FalseNoneNoneFalseNoneFalse6412.00
290117795243None8.01Errection of Transformer & Structures.( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) Errection of 25 to 63 KVA Transformer.( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.No1336.161336.161.0FalseNoneNoneFalseNoneFalse1336.160
290117895243None13.01Fixing of DOLO , GOS , LA, FUSE Board, Service Mains, Spacer, Insulator etc., ( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) Fixing of DOLO CUT OUT / Horn Gap Fuse including fixing of Cross arm and wiring.( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Each265.44265.441.0FalseNoneNoneFalseNoneFalse265.440
290117995243None13.02Fixing of GOS including wiring ( 11 KV Single Break 200 Amps).( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set1236.481236.481.0FalseNoneNoneFalseNoneFalse1236.480
290118095243None13.06Fixing of 3 Nos Lightning Arrestor including wiring.( COMMON Electrical SR BESCOM 2023-24, Labour 11 KV System ) ) ---- including cost and conveyance of all materials with all lead and lift, loading and unloading, usage of Machinery and equipments, transportation charges, labour charges, and all other incidental charges etc., complete as per standard technical specification, and directions of the Engineer in charge of work.Set133.28133.281.0FalseNoneNoneFalseNoneFalse133.280
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17095372090000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17095372090000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17095372090000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17095372090000NoneNoneELIGIBILITYConditional tenders are not acceptedNone
17095372090000NoneNoneELIGIBILITYThe employer reserves the right to reject one and all tenders without assigning any reason there of.None
17095372090000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E- procurement portalNone
17095372090000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tenderNone
17095372090000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Blore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17095372090000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17095372090000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17095372090000NoneNoneELIGIBILITYThe tenderer should submit the Registration Certificate along with technical bid.None
17095372090000NoneNoneELIGIBILITYOriginal documents/ Certificates enclosed must be produced in the office of Executive Engineer at the time of opening of technical bid.None
17095372090000NoneNoneELIGIBILITYAll the items in the tender are inclusive of cost and conveyance of all materials, all lead ,lift, loading, unloading, transportation, labour, hire chares of machinery , curing for concrete worksNone
17095372090000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour actNone
17095372090000NoneNoneELIGIBILITYIn case of the death of a contractor, after executing the agreement / commencement of the work, his legal heir, is an eligible registered contractor and is willing, can execute and complete the work, at the accepted tender rates, irrespective of the cost of the workNone
17095372090000NoneNoneELIGIBILITYDepartment will not supply any materialsNone
17095372090000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management , plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completionNone
17095372090000NoneNoneELIGIBILITYThe contractor should maintain the work for the period of 2 year (Two year) after the completion of the work at his own costNone
17095372090000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Bid document KW- IV.None
17095372090000NoneNoneELIGIBILITYPayment of EMD of Rs100000 shall be through E payment and remaining amount through the Bank Guarantee Banker s Cheque/Demand Draft/Pay Order,in favour of Executive Engineer,and shall be valid for 90 days beyond the validity of tender.None
17095372090000NoneNoneELIGIBILITYThe tenderer should bear all cost associated with the preparation and submission of his tender and the employer will in no case be resposble and liable for those cost.The cost of the tender form shall not be refundableNone
17095372090000NoneNoneELIGIBILITYTo qualify award of this contract the tenderer should submit proof of work qualification,for having executed similar nature of works,costing not less than 50 % of the value of work.None
17095372090000NoneNoneELIGIBILITYMaterials like Bitumen, steel,cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority before used on the work.None
17095372090000NoneNoneELIGIBILITYPERFORMANCE SECURITY The successful tenderer shall furnish Performance Security Deposit (Achievement Guarantee ) at 3% of the contract price plus additional security for unbalanced tender with in 20 days after approve of tender as per rule 25.5 of the tender and clause 44 of the agreement in the form of cash/Bankers Cheque,D.D,Pay order Bank Guarantee, in the nature of EXECUTIVE ENGINEER,PWD Udupi Div.None
17095372090000NoneNoneELIGIBILITYGST of 18% shall be paid to the tendered amount seperatelyNone
17095372090000NoneNoneELIGIBILITYContractors should be registered with KPWD Class II & above Registration and the tenderer should submit the Registration Certificate along with technical bid.None
17095372090000NoneNoneELIGIBILITYIncrease in GST shall not be paid in the extended period of contract for which the contractor alone is responsible for delay as determined by the authority while granting the extension of time.None
17095372090000NoneNoneELIGIBILITYAny tender aggrieved by an order passed by the tender accepting authority other than the government under section 13 may appeal through Karnataka Public Procurement Portal only. written appeals will not be accepted.None
17095372090000NoneNoneELIGIBILITYEstimate rates are excluding GST as per Common SR 2021-22 and prevailing GST (18% of Amount Put to tender) amount is kept in form of Lump sum in sanctioned estimate according to guidelines in Common SR (GO:PWD 51 RDF 2019 Bangaluru Dt:18.03.2022). Therefore, amount put to Tender and ECV amount are excluding GST. KPPP-PORTAL format has No Options to add GST Separately at stage of Draft Tender Schedule Process for Over All amount put to Tender , tender has been inviting through an Option with INCLUSIVE. But the item wise rates do not include GST. Hence, GST will be paid separately for the quoted amount accordingly. Declaration Certificate must be attached mandatorily.None
17095372090000NoneNoneELIGIBILITYSteel Centering and Steel Scaffolding shall be used for all centering and scaffolding formworks as per specification of Schedule of Rates.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (b) Satisfactorily completed as prime contractor, at least (i.e. 2018-19 to 2022-23 )one similar work such as Building construction work of value not less than Rs 179.08LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Earth Work Excavation in 1.Hard Rock With Blasting -1391Cum,2. Earth Work Excavation in all Kinds Of Soil -380Cum, 3.PCC / RCC Concrete -887 Cum, 4.Solid Blocks/ BBM/ Latrite Masonary-693 Sqm,5. TMT Steel Reinforcement -50 Tonne, 6.Plastering -4859Sqm, 7.Granite/Vitrified/Ceramic Flooring and Cladding -1175Sqm .Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical Building works of Rs. 13.00lakhs (not less than 50% of electrical works) n any one year)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar water supply/ sanitary for Buildings works totallng Rs.5.80lkhs(not less than 50% of water supply/sanitary engineering works) n any one year.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work-done certificate from not below the rank of Executive Engineer or equivalent
NoneNoneNoneNoneSection 2: ITT 3.3 - Each Tenderer should further demonstrate: (b) Machineries could be on Lease/Hire/Ownership:1.Self Loaded Concrete mixer-1 No, 2.Excavator -1 No, 3.Tipper -3 Nos, 4.Water Tank -5000 liters Capacity -1 No, 5.Self operating lift -1 No,6.Steel Centering/ Scaffolding Materials -500sqm.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by RTO or Sale Deed or Purchase Invoice or heired documents
NoneNoneNoneNoneList of works for which tenders already submittedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach details in prescribed format in 1.5(B) Section
NoneNoneNoneNoneSection 2: ITT 3.3 Each Tenderer should further demonstrate: (a) Machineries to be owned:1.Concrete mixture machine -2 Nos, 2.Self Loaded Concrete mixer -1 No, 3.Excavator -1 No, 4.Tipper -2 Nos,5. Water Tank -5,000 liters Capacity-1 No,6. Steel Centering/ Scaffolding Materials -500sqmCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- RC issued by RTO or Sale Deed or Purchase Invoice
NoneNoneNoneNoneThe bidder should be a Class-II and Above KPWD contractor.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Registeration Certificate here
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Engineer / Staff chart
NoneNoneNoneNoneSection 2: ITT 3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years (i.e. 2018-19 to 2022-23 ) (a) achieved in atleast two financial year, a minimum financial turn over (in all classes of civil engineering construction works only) of Rs 716.35 Lakhs.Financial Statusprofit and loss statement ,Balance sheets certified from an Registered Chartered Accountant with Indent Number
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach Turnover Certificate from Registered CA with profit and loss statement
NoneNoneNoneNoneSection 2: ITT 3.3 - Each Tenderer should further demonstrate : (b) Liquid assets and /or availability of credit facilities of no less than Rs. 107.45 Lakhs (Credit lines/ letter of credit/ certificates from nationalized / scheduled banks in prescribed format for meeting the fund requirement etc.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneList of Financial Resources with CertificatesFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersList of existing commitments and ongoing work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Attach details in prescribed format in 1.5(A) Section
NoneNoneNoneNoneBanker Details for referenceOthersContact number, address and bank details
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Contact number, address and bank details in letterhead
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
The bidder should be a Class-II & above PWD contractor With contact numberTrueTechnical Bid
Work-done certificateTrueTechnical Bid
Attach GST Declaration certificate in prescribed formatTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709537863000
version0
createdDateNone
modifiedDateNone
blockNumberO/o Executive Engineer, Public Work Department, Udupi
streetNone
cityUdupi
stateKarnataka
pin576101
tenderRecallDTONone