| 2902623 | 95324 | None | code01 | Main Buidling Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 186.0 | 186.0 | 81.97 | False | None | None | False | None | False | 15246.42 | 0 |
| 2902624 | 95324 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 4859.0 | 4859.0 | 31.18 | False | None | None | False | None | False | 151503.62 | 0 |
| 2902625 | 95324 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 5943.0 | 5943.0 | 46.03 | False | None | None | False | None | False | 273556.29 | 0 |
| 2902626 | 95324 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 5543.0 | 5543.0 | 21.91 | False | None | None | False | None | False | 121447.13 | 0 |
| 2902627 | 95324 | None | code05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 5352.0 | 5352.0 | 17.5 | False | None | None | False | None | False | 93660.0 | 0 |
| 2902628 | 95324 | None | code06 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Kg | 87.15 | 87.15 | 5227.45 | False | None | None | False | None | False | 455572.2675 | 0 |
| 2902629 | 95324 | None | code07 | As per recommendations of Technical working group, rates for formwork shall be added on percentage basis to the finished concrete item rate as per table below Columns Footing complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 178.29 | 178.29 | 6.91 | False | None | None | False | None | False | 1231.9839 | 0 |
| 2902630 | 95324 | None | code08 | Columns complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work | Cum | 4160.1 | 4160.1 | 8.08 | False | None | None | False | None | False | 33613.608 | 0 |
| 2902631 | 95324 | None | code09 | Plinth Beams complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 2971.5 | 2971.5 | 6.27 | False | None | None | False | None | False | 18631.305 | 0 |
| 2902632 | 95324 | None | code10 | Beams & Lintels of Building complete the work complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 3565.8 | 3565.8 | 7.27 | False | None | None | False | None | False | 25923.366 | 0 |
| 2902633 | 95324 | None | code11 | Roof (Straight & Arched) complete the workcomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 2971.5 | 2971.5 | 17.5 | False | None | None | False | None | False | 52001.25 | 0 |
| 2902634 | 95324 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 6696.0 | 6696.0 | 32.95 | False | None | None | False | None | False | 220633.2 | 0 |
| 2902635 | 95324 | None | code13 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 204.0 | 204.0 | 82.42 | False | None | None | False | None | False | 16813.68 | 0 |
| 2902636 | 95324 | None | code14 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 90393.0 | 90393.0 | 0.135 | False | None | None | False | None | False | 12203.055 | 0 |
| 2902637 | 95324 | None | code15 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 5074.0 | 5074.0 | 3.15 | False | None | None | False | None | False | 15983.1 | 0 |
| 2902638 | 95324 | None | code16 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 274.0 | 274.0 | 305.66 | False | None | None | False | None | False | 83750.84 | 0 |
| 2902639 | 95324 | None | code17 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 322.0 | 322.0 | 302.9 | False | None | None | False | None | False | 97533.8 | 0 |
| 2902640 | 95324 | None | code18 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Kg | 143.0 | 143.0 | 378.0 | False | None | None | False | None | False | 54054.0 | 0 |
| 2902641 | 95324 | None | code19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work | Sqm | 455.0 | 455.0 | 171.0 | False | None | None | False | None | False | 77805.0 | 0 |
| 2902642 | 95324 | None | code20 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 105.0 | 105.0 | 363.13 | False | None | None | False | None | False | 38128.65 | 0 |
| 2902643 | 95324 | None | code21 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 136.0 | 136.0 | 302.9 | False | None | None | False | None | False | 41194.4 | 0 |
| 2902644 | 95324 | None | code22 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm m2 complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 1261.0 | 1261.0 | 95.76 | False | None | None | False | None | False | 120753.36 | 0 |
| 2902645 | 95324 | None | code23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 83.0 | 83.0 | 305.66 | False | None | None | False | None | False | 25369.78 | 0 |
| 2902646 | 95324 | None | code24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargecomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 90.0 | 90.0 | 36.0 | False | None | None | False | None | False | 3240.0 | 0 |
| 2902647 | 95324 | None | code25 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 3.0 | 3.0 | 1000.0 | False | None | None | False | None | False | 3000.0 | 0 |
| 2902648 | 95324 | None | code26 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existingPVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. I. Point wiring using class A Materials a) Short point up to 3Mtr from tapping point to out let via switch complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work | Each | 200.0 | 200.0 | 2.0 | False | None | None | False | None | False | 400.0 | 0 |
| 2902649 | 95324 | None | code27 | b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 275.0 | 275.0 | 3.0 | False | None | None | False | None | False | 825.0 | 0 |
| 2902650 | 95324 | None | code28 | c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 400.0 | 400.0 | 5.0 | False | None | None | False | None | False | 2000.0 | 0 |
| 2902651 | 95324 | None | code29 | Supplying 6 A flush type socket and 6 Amps flush type SP switch either surface / flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6 Amps 3/5 Way complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 132.0 | 132.0 | 6.0 | False | None | None | False | None | False | 792.0 | 0 |
| 2902652 | 95324 | None | code30 | Supply and fixing of Bakelite DP/ Socket/ Switch with / without neon indicator over existing wood board or flush mounting in plastic plates/ nitches as per IS 1293 and IS 3854 complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. a) 32 Amps Flush / projected type DP switch complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 182.0 | 182.0 | 4.0 | False | None | None | False | None | False | 728.0 | 0 |
| 2902653 | 95324 | None | code31 | b) 16 Amps Flush type Universal Socket complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 162.0 | 162.0 | 3.0 | False | None | None | False | None | False | 486.0 | 0 |
| 2902654 | 95324 | None | code32 | Supplying patti type fluorescent tube light fitting of fluorescent tube fitting of 4' - suitable for 28 watts fluorescent tube fitting, made out of M.S sheet and stove enameled with HF Eletronic Ballast, locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 Volts A C Supply including T5 lamp. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 300.0 | 300.0 | 10.0 | False | None | None | False | None | False | 3000.0 | 0 |
| 2902655 | 95324 | None | code33 | Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL fittings indoor on the wall / ceiling/ rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps on wall / ceiling / rafter / girders complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 110.0 | 110.0 | 5.0 | False | None | None | False | None | False | 550.0 | 0 |
| 2902656 | 95324 | None | code34 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300 mm etc., as required 25 mm complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 24.0 | 24.0 | 15.0 | False | None | None | False | None | False | 360.0 | 0 |
| 2902657 | 95324 | None | code35 | Wiring for lighting / power circuit using one of PVC insulated 1100 v grade, multistand copper with low conductor resistance single core wire in open or consealed system of wiring. With specified IS 694 : 1990 & confirming to GTP I. Group A Materials complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. a.1 sqmm complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 14.0 | 14.0 | 50.0 | False | None | None | False | None | False | 700.0 | 0 |
| 2902658 | 95324 | None | code36 | b.1.5 sqmm complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 20.5 | 20.5 | 100.0 | False | None | None | False | None | False | 2050.0 | 0 |
| 2902659 | 95324 | None | code37 | c. 2.5 sqmm complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 32.0 | 32.0 | 100.0 | False | None | None | False | None | False | 3200.0 | 0 |
| 2902660 | 95324 | None | code38 | Supplying of LED floodlight with 110 W system power consumption pressure die cast aluminum housing with powder coating with IP 65 protection. 1200-275 V voltage with electronic Driver, PF 0.9, should meet ANSI 2G Vibration test, Compliance to UL/ CE with Class I system rating shall be 50K hrs @ Lumen maintenance of 70%, system efficency 80lm / w. Over load & short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB.. Top access steet light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED light fixture with 110 W system power consumption. LED efficiency 130 lm/ w at 1 w & fixture efficiency 80lm/ w with nominal CRI 75. Warranty of 5 Yrs. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Nos. | 17600.0 | 17600.0 | 2.0 | False | None | None | False | None | False | 35200.0 | 0 |
| 2902661 | 95324 | None | code39 | Fixing halogen/ metal halide/ SVL/ IL/ LED floodlight fitting over existing pole/ wall ceiling including clamps, bolts, nuts & wiring using suitable capacity wires. complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
| 2902662 | 95324 | None | code40 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etccomplete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. a) 10" x 8" x 1.5" complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work | Each | 77.0 | 77.0 | 8.0 | False | None | None | False | None | False | 616.0 | 0 |
| 2902663 | 95324 | None | code41 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden / panel using necessary nuts, bolts & washers 16 Amps complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 117.0 | 117.0 | 2.0 | False | None | None | False | None | False | 234.0 | 0 |
| 2902664 | 95324 | None | code42 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required. a) 5-32Amps SP Group 'A'complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work | Each | 434.0 | 434.0 | 10.0 | False | None | None | False | None | False | 4340.0 | 0 |
| 2902665 | 95324 | None | code43 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting etc., complete. II. Double Door b) 8Way SP &N Group 'A'complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work | Each | 1450.0 | 1450.0 | 1.0 | False | None | None | False | None | False | 1450.0 | 0 |
| 2902666 | 95324 | None | code44 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 x 400 x 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.complete with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 2999.7 | 2999.7 | 2.0 | False | None | None | False | None | False | 5999.4 | 0 |