| 2682188 | 83669 | None | 1.4 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In soft rock Depth upto 1.5 m | Cum | 620.48 | 620.48 | 37.73 | False | None | None | False | None | False | 23410.7104 | 0 |
| 2682189 | 83669 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of
all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6707.68 | 6707.68 | 5.56 | False | None | None | False | None | False | 37294.7008 | 0 |
| 2682190 | 83669 | None | 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. and
down size & with approved sand including hand packing, ramming, watering,
including cost of all materials and labour with all lead and lift complete as per
specifications. | Cum | 3003.84 | 3003.84 | 5.66 | False | None | None | False | None | False | 17001.7344 | 0 |
| 2682191 | 83669 | None | 5.6 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Foundation in CM 1:6 | Cum | 7138.88 | 7138.88 | 11.133 | False | None | None | False | None | False | 79477.15104 | 0 |
| 2682192 | 83669 | None | 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 1:6. | Cum | 7221.76 | 7221.76 | 3.72 | False | None | None | False | None | False | 26864.9472 | 0 |
| 2682193 | 83669 | None | 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. | Cum | 7565.6 | 7565.6 | 12.68 | False | None | None | False | None | False | 95931.808 | 0 |
| 2682194 | 83669 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 297.92 | 297.92 | 11.0 | False | None | None | False | None | False | 3277.12 | 0 |
| 2682195 | 83669 | None | 2.2.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9580.03 | 9580.03 | 5.52 | False | None | None | False | None | False | 52881.7656 | 0 |
| 2682196 | 83669 | None | 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 100191.84 | 100191.84 | 1.0422 | False | None | None | False | None | False | 104419.935648 | 0 |
| 2682197 | 83669 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10644.48 | 10644.48 | 7.386 | False | None | None | False | None | False | 78620.12928 | 0 |
| 2682198 | 83669 | None | 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x150x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications | Sqm | 1236.48 | 1236.48 | 13.2 | False | None | None | False | None | False | 16321.536 | 0 |
| 2682199 | 83669 | None | 9.12.2 | Providing and laying vitrified floor tiles with thickness 9-10 mm in
different sizes with water absorption less than 0.08% and conforming to
IS: 15622, of approved make, in all colours and shades, laid on 20mm thick
cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement
slurry @ 3.3 kg/ m2 including grouting the joints with white cement and
matching pigments etc., complete | Sqm | 1282.4 | 1282.4 | 27.0 | False | None | None | False | None | False | 34624.8 | 0 |
| 2682200 | 83669 | None | 12.11 | Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications | Cum | 154642.88 | 154642.88 | 0.2906 | False | None | None | False | None | False | 44939.220928 | 0 |
| 2682201 | 83669 | None | 11.34 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding | Kg | 188.16 | 188.16 | 113.4 | False | None | None | False | None | False | 21337.344 | 0 |
| 2682202 | 83669 | None | 12.15 | Providing and fixing in position fully panelled Honne wood shutters for
doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm
wide top rail and stiles 100mm wide as per drawing and panels of 25mm
thick including cost of materials, labour, usage charges complete as per
specifications | Sqm | 8337.28 | 8337.28 | 1.89 | False | None | None | False | None | False | 15757.4592 | 0 |
| 2682203 | 83669 | None | 12.44 | Providing and fixing in position fully glazed for windows shutters with
Honne wood stiles and rails of 35mm. thick 75mm wide in single shutters
with 4mm thick plain glass fixed with wooden beading including cost of
materials, labour charges, usage charges complete as per specifications.
(excluding cost of fixtures) | Sqm | 6144.32 | 6144.32 | 5.4 | False | None | None | False | None | False | 33179.328 | 0 |
| 2682204 | 83669 | None | 12.70.2 | Providing and fixing oxidised M.S. double acting spring hinges with necessary
screws etc. complete | Nos | 313.6 | 313.6 | 18.0 | False | None | None | False | None | False | 5644.8 | 0 |
| 2682205 | 83669 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock
with 6 levers and a pair of lever handles of approved quality with necessary
screws etc. complete | Nos | 1178.24 | 1178.24 | 1.0 | False | None | None | False | None | False | 1178.24 | 0 |
| 2682206 | 83669 | None | 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 396.48 | 396.48 | 204.31 | False | None | None | False | None | False | 81004.8288 | 0 |
| 2682207 | 83669 | None | 9.10 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1238.72 | 1238.72 | 18.54 | False | None | None | False | None | False | 22965.8688 | 0 |
| 2682208 | 83669 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the
wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge | Rmtr | 356.16 | 356.16 | 4.98 | False | None | None | False | None | False | 1773.6768 | 0 |
| 2682209 | 83669 | None | 12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom
rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges | Sqm | 1778.56 | 1778.56 | 1.58 | False | None | None | False | None | False | 2810.1248 | 0 |
| 2682210 | 83669 | None | 10.2 | Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 124.32 | 124.32 | 204.31 | False | None | None | False | None | False | 25399.8192 | 0 |
| 2682211 | 83669 | None | 11.30.2 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, Clerestory windows, all complete with : 5.5 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 1408.96 | 1408.96 | 0.36 | False | None | None | False | None | False | 507.2256 | 0 |
| 2682212 | 83669 | None | 11.35.11 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-incharge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 506.24 | 506.24 | 8.1 | False | None | None | False | None | False | 4100.544 | 0 |
| 2682213 | 83669 | None | 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | Rmtr | 356.16 | 356.16 | 30.0 | False | None | None | False | None | False | 10684.8 | 0 |
| 2682214 | 83669 | None | 13.31.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes | Rmtr | 448.0 | 448.0 | 30.0 | False | None | None | False | None | False | 13440.0 | 0 |
| 2682215 | 83669 | None | 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. | Nos. | 812.0 | 812.0 | 3.0 | False | None | None | False | None | False | 2436.0 | 0 |
| 2682216 | 83669 | None | 13.15 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. 20 mm nominal bore, 120 mm long, weighing not less than 198 g | Nos | 566.72 | 566.72 | 1.0 | False | None | None | False | None | False | 566.72 | 0 |
| 2682217 | 83669 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank | Ltr | 10.08 | 10.08 | 1000.0 | False | None | None | False | None | False | 10080.0 | 0 |
| 2682218 | 83669 | None | 14.1.1 | White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Nos | 5470.08 | 5470.08 | 1.0 | False | None | None | False | None | False | 5470.08 | 0 |
| 2682219 | 83669 | None | 13.50.1 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 150 mm nominal dia Pipe | Rmtr | 1784.16 | 1784.16 | 8.0 | False | None | None | False | None | False | 14273.28 | 0 |
| 2682220 | 83669 | None | 1.1 | Supplying heavy gauge PVC conduit pipe ……mm dia mm thick
| Rmtr | 40.0 | 40.0 | 100.0 | False | None | None | False | None | False | 4000.0 | 0 |
| 2682221 | 83669 | None | 1.2 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. | Rmtr | 21.0 | 21.0 | 61.0 | False | None | None | False | None | False | 1281.0 | 0 |
| 2682222 | 83669 | None | 1.3 | Supplying and fixing PVC/metal conduit Deep junction box | Nos | 43.0 | 43.0 | 2.0 | False | None | None | False | None | False | 86.0 | 0 |
| 2682223 | 83669 | None | 1.4 | Short point upto 3Mtr from tapping point to out let via switch | Point | 160.0 | 160.0 | 4.0 | False | None | None | False | None | False | 640.0 | 0 |
| 2682224 | 83669 | None | 1.7 | Medium point above 3Mtr upto 6Mtr from tapping point to outlet | Point | 275.0 | 275.0 | 5.0 | False | None | None | False | None | False | 1375.0 | 0 |
| 2682225 | 83669 | None | 1.8 | Long point above 6Mtr upto 10Mtr from tapping point to out | Point | 400.0 | 400.0 | 6.0 | False | None | None | False | None | False | 2400.0 | 0 |
| 2682226 | 83669 | None | 1.9 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments | Rmtr | 20.5 | 20.5 | 200.0 | False | None | None | False | None | False | 4100.0 | 0 |
| 2682227 | 83669 | None | 1.10 | 2.5 sqmm | Rmtr | 32.0 | 32.0 | 150.0 | False | None | None | False | None | False | 4800.0 | 0 |
| 2682228 | 83669 | None | 1.11 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. | Nos | 95.0 | 95.0 | 2.0 | False | None | None | False | None | False | 190.0 | 0 |
| 2682229 | 83669 | None | 1.12 | 8 Way | Nos | 145.0 | 145.0 | 2.0 | False | None | None | False | None | False | 290.0 | 0 |
| 2682230 | 83669 | None | 1.13 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Nos | 110.0 | 110.0 | 2.0 | False | None | None | False | None | False | 220.0 | 0 |
| 2682231 | 83669 | None | 1.14 | 8 Module | Nos | 400.0 | 400.0 | 2.0 | False | None | None | False | None | False | 800.0 | 0 |
| 2682232 | 83669 | None | 1.15 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. | Nos | 70.0 | 70.0 | 10.0 | False | None | None | False | None | False | 700.0 | 0 |
| 2682233 | 83669 | None | 1.16 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. | Nos | 434.0 | 434.0 | 2.0 | False | None | None | False | None | False | 868.0 | 0 |
| 2682234 | 83669 | None | 1.16 | Supplying and fixing regular MCB distribution boards | Nos | 1800.0 | 1800.0 | 1.0 | False | None | None | False | None | False | 1800.0 | 0 |
| 2682235 | 83669 | None | 1.17 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and | Nos | 4150.0 | 4150.0 | 1.0 | False | None | None | False | None | False | 4150.0 | 0 |
| 2682236 | 83669 | None | 1.18 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. | Rmtr | 130.0 | 130.0 | 10.0 | False | None | None | False | None | False | 1300.0 | 0 |
| 2682237 | 83669 | None | 1.18 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring | Nos | 130.0 | 130.0 | 10.0 | False | None | None | False | None | False | 1300.0 | 0 |
| 2682238 | 83669 | None | 1.19 | Supplying & fixing of feet - PVC Batten with integrated LED tube | Nos | 375.0 | 375.0 | 3.0 | False | None | None | False | None | False | 1125.0 | 0 |
| 2682239 | 83669 | None | 1.21 | Supply of round/square recess/surface mounted rolling type LED Down light with W GU 10 LED Lamp Rib | Nos | 768.0 | 768.0 | 3.0 | False | None | None | False | None | False | 2304.0 | 0 |