createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709561879239
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeONE_COVER
evaluationTypeTextOne Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee770.00
emd50000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose14-03-2024 17:00:00
tenderQueryClose14-03-2024 16:30:00
technicalBidOpenNone
publishedDate04-03-2024 20:23:50
publishedByPostDMA_EE1_CC_DVG
publishedByUserKPE12146 - MANOHAR B
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManohar B EE
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08192234444
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1709561879274
version5
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT14419
titleCONSTRUCTION OF BUILDING FOR PROVIDING FACILITIES OF WAZHUKANA AT SSM NAGAR B BLOCK KHABRASTHAN IN WARD NO 02
descriptionConstruction of Building for Providing facility of Wazukhana at SSM Nagar B Block Khabrasthan in ward no 02
categoryWORKS
categoryTextWorks
ecv3080000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2160
locationNameDMA City Corporation Davanagere
provisionalAmount3080000.0
groupOverheadTotal597313.71
fileNumberDMA/DCC/W02/EDGAH/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17095618790000NoneNoneOther WorksCONSTRUCTION OF BUILDING FOR PROVIDING FACILITIES OF WAZHUKANA AT SSM NAGAR B BLOCK KHABRASTHAN IN WARD NO 022482686.29
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
291382495660None1.14Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete.In all kinds of soils Depth upto 3 m(common sr) (P No.5, I No.1.14). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum107.1107.168.4FalseNoneNoneFalseNoneFalse7325.640
291382595660None2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates(P No.15, I No.2.1.3). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum6288.456288.455.4FalseNoneNoneFalseNoneFalse33957.630
291382695660None1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(P No.7, I No.1.9). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum279.3279.355.0FalseNoneNoneFalseNoneFalse15361.50
291382795660None3.11Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work (roads and bridges) ( p.nO15., I.NO.3.11) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum89.2589.2513.4FalseNoneNoneFalseNoneFalse1195.950
291382895660None2.1.4Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates(P No.15, I No.2.1.4). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum6527.856527.856.22FalseNoneNoneFalseNoneFalse40603.2270
291382995660None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(P No.13, I No.6.7). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum8621.558621.5556.93FalseNoneNoneFalseNoneFalse490824.84150
291383095660None2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(I NO 2.4.2, PG NO 16) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum6639.156639.1520.89FalseNoneNoneFalseNoneFalse138691.84350
291383195660NoneAPPENDIX 1shuttering for Plinth Beams of Buildings -50% OF Percentage on finished rate of concrete per m3 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum3319.573319.576.49FalseNoneNoneFalseNoneFalse21544.00930
291383295660None2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(P No.16, I No.2.5.1). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum6961.56961.537.28FalseNoneNoneFalseNoneFalse259524.720
291383395660NoneAPPENDIX 1shuttering for RCC Roof Slabs of Buildings -50% OF Percentage on finished rate of concrete per m3 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum3480.753480.7520.63FalseNoneNoneFalseNoneFalse71807.87250
291383495660NoneAPPENDIX 1shuttering for RCC Columns-70% OF Percentage on finished rate of concrete per m3 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum4873.054873.055.74FalseNoneNoneFalseNoneFalse27971.3070
291383595660NoneAPPENDIX 1shuttering for RCC Beams, Lintels -60% OF Percentage on finished rate of concrete per m3 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Cum4176.94176.98.17FalseNoneNoneFalseNoneFalse34125.2730
291383695660None2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification(P No.18, I No.2.11a). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Tonne93929.8593929.854.58FalseNoneNoneFalseNoneFalse430198.7130
291383795660None9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm(P No.60 I No.9.12.2). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Sqm1202.251202.25135.74FalseNoneNoneFalseNoneFalse163193.4150
291383895660None11.34BProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.(I no 11.34B, pg no 86) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Kg192.15192.151522.5FalseNoneNoneFalseNoneFalse292548.3750
291383995660None8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(P No.42 I No.8.8). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Sqm389.55389.55466.24FalseNoneNoneFalseNoneFalse181623.7920
291384095660None8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(P No.50 I No.8.51). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Sqm105.0105.0274.09FalseNoneNoneFalseNoneFalse28779.450
291384195660None8.24Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P No.45 I No.8.24). ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Sqm113.4113.4379.84FalseNoneNoneFalseNoneFalse43073.8560
291384295660None10.9.2Supply and delivery at site wrought middle steel (galvanized) GI tee confirming to IS 1239-II, 1991 with latest amendments if any 20mm Dia GI Tee Vol-5 Item No.10.9.2 Page No.130. ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m112.35112.3579.0FalseNoneNoneFalseNoneFalse8875.650
291384395660None10.6.2Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any.Vol-5 Item No.10.6.2 Page No.129 20mm Dia GI Collar. ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m103.95103.9579.0FalseNoneNoneFalseNoneFalse8212.050
291384495660None13.18.2Providing and fixing PTMT stop cock of approved quality and colour20 mm nominal bore, 89 mm long, weighing not less than 88 g 20 mm nominal bore Vol-2 Item No.13.18.2 Page No.120. ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m151.2151.279.0FalseNoneNoneFalseNoneFalse11944.80
291384595660None11.15.8Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 80 mm dia GM (Copper alloy) Gate Valve Vol-2 Item No.11.15.8 Page No.133 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each1997.11997.14.0FalseNoneNoneFalseNoneFalse7988.40
291384695660None13.34AProviding and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. Vol-2 Item No.13.34(A) Page No.123 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
291384795660None13.31.5Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 40 mm nominal dia Pipes Vol-2 Item No.13.31.5 Page No.122. ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m562.8562.830.0FalseNoneNoneFalseNoneFalse16884.00
291384895660None13.31.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 20 mm nominal dia Pipes Vol-2 Item No.13.31.2 Page No.122. ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m254.1254.1150.0FalseNoneNoneFalseNoneFalse38115.00
291384995660None2.1.1Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( PWD Ele SR 2023-24 P-4, I-2.1.1, 2.1.2, 2.1.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Point285.0285.02.0FalseNoneNoneFalseNoneFalse570.00
291385095660None2.1.2Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( PWD Ele SR 2023-24 P-4, I-2.1.1, 2.1.2, 2.1.3)Short point upto 3Mtr from tapping point to out let via switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Point394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
291385195660None2.1.3Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.( PWD Ele SR 2023-24 P-4, I-2.1.1, 2.1.2, 2.1.3)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Point570.0570.01.0FalseNoneNoneFalseNoneFalse570.00
291385295660None3.6.1Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Ele SR 2023-24 P-8, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.7, 3.6.10 ) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No102.0102.08.0FalseNoneNoneFalseNoneFalse816.00
291385395660None3.6.3Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Ele SR 2023-24 P-8, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.7, 3.6.10 )6A One Way Switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No171.0171.06.0FalseNoneNoneFalseNoneFalse1026.00
291385495660None3.6.4Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Ele SR 2023-24 P-8, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.7, 3.6.10 )6A Three Way socket ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No357.0357.04.0FalseNoneNoneFalseNoneFalse1428.00
291385595660None3.6.7Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Ele SR 2023-24 P-8, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.7, 3.6.10 )Stepped Fan Regulator Two Module ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No180.0180.06.0FalseNoneNoneFalseNoneFalse1080.00
291385695660None3.6.10Supplying and fixing of modular switch/ socket & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Ele SR 2023-24 P-8, I.No-3.6.1, 3.6.3, 3.6.4, 3.6.7, 3.6.10 )16A One Way Switch ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No236.0236.06.0FalseNoneNoneFalseNoneFalse1416.00
291385795660None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD Ele SR 2023-24 P-4, I.No-2.3.2, 2.3.3 and 2.3.4 ) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.MT26.026.030.0FalseNoneNoneFalseNoneFalse780.00
291385895660None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD Ele SR 2023-24 P-4, I.No-2.3.2, 2.3.3 and 2.3.4 )1.5 mm2 ( P-4, I-2.3.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m42.042.030.0FalseNoneNoneFalseNoneFalse1260.00
291385995660None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD Ele SR 2023-24 P-4, I.No-2.3.2, 2.3.3 and 2.3.4 )2.5 mm2 ( P-4, I-2.3.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m63.063.015.0FalseNoneNoneFalseNoneFalse945.00
291386095660None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (PWD Ele SR 2023-24 P-4, I.No-2.3.2, 2.3.3 and 2.3.4 )4 mm2 ( P-4, I-2.3.4) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each137.0137.06.0FalseNoneNoneFalseNoneFalse822.00
291386195660None3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way (PWD Ele 2023-24 Pg No 7 Item No 3.3.3) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each173.0173.06.0FalseNoneNoneFalseNoneFalse1038.00
291386295660None3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way (PWD Ele 2023 24 Pg No 7 Item No 3.3.4) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each261.0261.06.0FalseNoneNoneFalseNoneFalse1566.00
291386395660None3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10/12 Way (PWD Ele SR 2023-24 Pg No 7 Item No 3.3.6) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each548.0548.05.0FalseNoneNoneFalseNoneFalse2740.00
291386495660None3.13.2Supplying and fixing of metal clad industrial plugs and sockets. 2pole+earth 250V PLUG 32A (PWD Ele SR 2023 24 Item No 3.13.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No63.063.04.0FalseNoneNoneFalseNoneFalse252.00
291386595660None12.46Supplying & Fixing of 70-150 W lamp holder 2 Pin ( PWD Ele SR 2023 24 P-51, I-12.46) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.m81.081.0100.0FalseNoneNoneFalseNoneFalse8100.00
291386695660None1.1.2Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick (PWD Ele SR 2023-24 P-01, I.No.- 1.1.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No646.0646.02.0FalseNoneNoneFalseNoneFalse1292.00
291386795660None3.7Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230V 50Hz AC supply & completetly wired on existing box.(PWD Ele SR 2023 24 P-08,I-3.7) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No241.0241.01.0FalseNoneNoneFalseNoneFalse241.00
291386895660None5.7.2Supplying & fixing of 32Amps Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.(PWD Ele SR P-10,I-5.7.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No1102.01102.01.0FalseNoneNoneFalseNoneFalse1102.00
291386995660None5.18.6Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63Amps DP. (PWD Ele SR P-16, I-5.18.6) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No6086.06086.01.0FalseNoneNoneFalseNoneFalse6086.00
291387095660None5.15.1Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA (PWD Ele SR 2023 24 P-15, I-5.15.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No4512.04512.01.0FalseNoneNoneFalseNoneFalse4512.00
291387195660None5.44.1Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally mbedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 300 mm x 214 mm(PWD Ele SR 2023 24 Pg No 20 I.No.5.44.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No269.0269.02.0FalseNoneNoneFalseNoneFalse538.00
291387295660None11.13.2Supplying of patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired with HF Electronic Ballast, Operating voltage range from 180V to 265V, 50Hz AC power supply excluding Tube. 1 x 4' Tube light fitting. (PWD Ele SR 2023 24 P-46,I-11.13.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No95.095.04.0FalseNoneNoneFalseNoneFalse380.00
291387395660None12.12.1Supplying and fixing/replacing of fluorescent tube. 18 to 40W (PWD Ele SR 2023 24 P-47, I-12.12.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No702.0702.04.0FalseNoneNoneFalseNoneFalse2808.00
291387495660None11.2.2Supplying & fixing retrofit type-PL- LED Lamp . W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF+ B242 0.95, power loss should 5% of lamp Wage short circuit & open circuit protection to be integrated in the circuit, THD less than 20, Life as per LM 79. The operating input voltage should be between 130 to 275 V. Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18-20 W (PWD Ele SR 2023 24 P-42, I-11.2.2) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No2984.02984.04.0FalseNoneNoneFalseNoneFalse11936.00
291387595660None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model (PWD Ele SR 2023 24 P-29,I No 6.3.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
291387695660None13.10Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. (PWD Ele SR 2023 24 P-56,I-13.10) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No78.078.06.0FalseNoneNoneFalseNoneFalse468.00
291387795660None3.14.5Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose (PWD Ele SR 2023 24 P-9, I.no-3.14.5) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No3510.03510.01.0FalseNoneNoneFalseNoneFalse3510.00
291387895660None12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long g buried in a pit…The pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 2mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia. (PWD Ele SR 2023 24 P-53, I-12.56 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Km141842.0141842.00.01FalseNoneNoneFalseNoneFalse1418.420
291387995660None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) (PWD Ele SR 2023 24 I no.-32.05 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Km66040.066040.00.01FalseNoneNoneFalseNoneFalse660.40
291388095660None11bLaying of cable in trench. (PWD Ele SR 2023 24 I no.-11b ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Mtr98.098.010.0FalseNoneNoneFalseNoneFalse980.00
291388195660None7.20.1Supply and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Sockets/Couplings/Tees/Bends/End-caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables. 40mm OD / 32mm ID (I no.-7.20.1 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Mtr205.0205.010.0FalseNoneNoneFalseNoneFalse2050.00
291388295660NoneI-2Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete.(As per Civil SR KSRB I-2, P-7)CC Cutting ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No122.0122.010.0FalseNoneNoneFalseNoneFalse1220.00
291388395660None13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders. (PWD Ele SR 2023 24 P-55,I-13.7.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.No1492.01492.02.0FalseNoneNoneFalseNoneFalse2984.00
291388495660None6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.(PWD Ele SR 2023 24 P-29, I-6.1) ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each2492.02492.01.0FalseNoneNoneFalseNoneFalse2492.00
291388595660None6.5.1Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep .(PWD Ele SR 2023 24 P-29, I-6.5.1 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each1927.01927.01.0FalseNoneNoneFalseNoneFalse1927.00
291388695660None5.1Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230/440 V 1/3 phase motor upto 5 HP. pwd electrical sr 2023-24 page no13 item no5.1 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each1449.01449.01.0FalseNoneNoneFalseNoneFalse1449.00
291388795660None5.30Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. item 5.30 page 18 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each9388.059388.051.0FalseNoneNoneFalseNoneFalse9388.050
291388895660None1.0Supply and fixing of branded new single phase mono block 1Hp motor.230v 50 hz ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each9388.059388.051.0FalseNoneNoneFalseNoneFalse9388.050
291388995660None8.55Providing and fixing RCC name board of size 1.35x0.60x0.04 0.10x0.10x2.60m in cement concrete M 20 proportion using20mm and down size graded metal machine mixed with10mm dia main steel bars and 8mm dia stirpes as shown indrawing. The board shall be provided with 12mm thick cement plaster in cement mortar 1:4 on both the sides. The poles shallbe embedded in the ground for a depth of 0.5 m with cementconcrete M 10 proportion. The board shall be fixed as per thedrawing and at the place indicated by the Engineer in chargeof the work. The cost includes excavation, cost of all materials,cost of steel, painting, centering, transportation charges &fixing charges.804roads and bridges(pg no 78 I no 8.55 ---- The work shall be carried out as per the detailed specifications, drawings and directions of the Engineer in charge of the work. The rates are inclusive of all lead and lift, hire chargers of machinery, labour, incidental charges all etc complete.Each6154.056154.051.0FalseNoneNoneFalseNoneFalse6154.050
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17095618800000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17095618800000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17095618800000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17095618800001NoneNoneELIGIBILITYCorrigendum / modifications / correction, if any, will be published in the KPP portal only.None
17095618800001NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid. Any discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected. The Employer reserves the right to reject any or all Tenders without assigning any reason or what so ever. Conditional tenders will not be accepted.None
17095618800001NoneNoneELIGIBILITYAs per Karnataka State Government order No.LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/BMS/2007 Dated 27-07-2007, a sum amounting to 1%of the bill amount will be deducted towards Construction Labour Welfare fund. Royalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17095618800001NoneNoneELIGIBILITYWork done certificate should be issued by competent authority not below the rank of Executive Engineer and Submitted Work done certificate should include E-PROCUREMENT INDENT NUMBER. The Tenderer shall scan Original Workdone certificates / Turnover Statements and any other documents specified by the employer and attach the scanned file to the Bid. The Original Documents shall be produced for physical verification within one week from the date of Technical bid opening or when called for during evaluation of tender.None
17095618800001NoneNoneELIGIBILITYa) Financial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2023-24. b) The Tenderer should maintain the Work during defective liability period i.e., ONE Year from the completion date. c) The Tenders are invited as per Standard tender Bid Document, All terms and conditions as per tender documents and Other details can be seen in the tender documents.None
17095618800000NoneNoneELIGIBILITYList of existing commitments and ongoing worksNone
17095618800000NoneNoneELIGIBILITYList of works for which tenders already submittedNone
17095618800001NoneNoneELIGIBILITYAs per Government Order NO: FD 675 EXP 12 /2020 Banglore Dated 22-12-2020 action will be taken if the documents submitted by the tenderer found to be misleading /forged or fake.None
17095618800001NoneNoneELIGIBILITYBidders have to quote and execute the work as per the detailed specification given in Sanctioned estimate and the instructions of the Engineer incharge. The copy of the estimate can be obtained from the Asst. Executive Engineers office, City Corporation Davanagere during Office hoursNone
17095618800001NoneNoneELIGIBILITYCertificate of registration in the labor Department / Provident Fund / ESI should be enclosed and shall engage a construction worker who is registered with the Karnataka Building and construction Workers Welfare Board.None
17095618800001NoneNoneELIGIBILITYAs per the Govt. Order No.DE 447 Exp-12/2022 Dated : 30-07-2022 GST will be added to the contract amount separately.None
17095618800001NoneNoneELIGIBILITYThe tenderer should be a PWD registered Contractor - Class-3 and aboveNone
17095620000000NoneNoneELIGIBILITYDetails As per 1.2 of Section 3 of Qualification information in Standard Bid document i.e., In last five years period achieved in at least two financial Year for other category and one Financial Year for SC & ST category an minimum annual financial turnover should not be less than cost of the work, Turnover certificate from CA with valid UDIN No. along with profit loss, Balance Sheet and IT ReturnsNone
17095620050000NoneNoneELIGIBILITYDetails As per 1.3 of Section 3 of Qualification information in Standard Bid document i.e., Satisfactorily completed at least one Similar work for other category of value not less than 50 Percent and Any Construction work for SC and ST category of value not less than 25 percent of cost of the work as prime contractor. Certificate issued by not below the rank of Executive Engineer or equivalent with eprocurement Indent NoNone
17095620170000NoneNoneELIGIBILITYDeclaration for the purpose of tax withholding 2022-23None
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Details as per 1.1 of Section 3 of Qualification information in Standard Bid document i.e., Registration certificateTrueTechnical Bid
Details As per 1.2 of Section 3 of Qualification information in Standard Bid document i.e., In last five years period achieved in at least two financial Year for other category and one Financial Year for SC & ST category an minimum annual financial turnover should not be less than cost of the work, Turnover certificate from CA with valid UDIN No. along with profit loss, Balance Sheet and IT ReturnsTrueTechnical Bid
Details As per 1.3 of Section 3 of Qualification information in Standard Bid document i.e., Satisfactorily completed at least one Similar work for other category of value not less than 50 Percent and Any Construction work for SC and ST category of value not less than 25 percent of cost of the work as prime contractor. Certificate issued by not below the rank of Executive Engineer or equivalent with eprocurement Indent No.TrueTechnical Bid
Details as per 1.4A, B, 1.5 and etc., of Section 3 of Qualification information in Standard Bid document.TrueTechnical Bid
Certificate of registration in the Labour Department/ Provident Fund /ESITrueTechnical Bid
Declaration for the purpose of tax withholding 2022-23TrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone