| 1709477804000 | 1 | None | None | Buildings | Construction of Aspirational toilet front of Public Hospital at w.no. w.no. 15 in limits of tmc bidadi | 1691094.2 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2897973 | 95015 | None | 1.1a1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the wor In all kinds of soils Depth upto 3 m (I. No 1.14.1, P. No-8, Vol-1 of PWD Common SR 2023-24) | Cum | 105.06 | 105.06 | 33.44 | False | None | None | False | None | False | 3513.2064 | 0 | | 2897974 | 95015 | None | 1.1a2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(I. No 1.9 P. No-7, Vol-1 of PWD Common SR 2023-24) | Cum | 273.98 | 273.98 | 13.82 | False | None | None | False | None | False | 3786.4036 | 0 | | 2897975 | 95015 | None | 1.1a3 | Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work (PWD SR Vol 3, 2023-24, Item no. 3.1, Page No.17) | Cum | 87.55 | 87.55 | 19.62 | False | None | None | False | None | False | 1717.731 | 0 | | 2897976 | 95015 | None | 1.1a4 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(I. No 4.1. P. No-5, Vol-2 of PWD Common SR 2023-24) | Sqm | 121.54 | 121.54 | 58.31 | False | None | None | False | None | False | 7086.9974 | 0 | | 2897977 | 95015 | None | 1.1a5 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6( M10) Using 40 mm nominal size graded crushed coarse aggregates (I. No 2.1.3 P. No-15, Vol-1 of PWD Common SR 2023-24) | Cum | 6353.73 | 6353.73 | 4.61 | False | None | None | False | None | False | 29290.6953 | 0 | | 2897978 | 95015 | None | 1.1a6 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.4, P. No-9 , Vol-2 of PWD Common SR 2023-24) | Cum | 6580.67 | 6580.67 | 29.87 | False | None | None | False | None | False | 196564.6129 | 0 | | 2897979 | 95015 | None | 1.1a7 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. (I. No 8.19.1 P. No-44 , Vol-2 of PWD Common SR 2023-24) | Sqm | 262.65 | 262.65 | 38.68 | False | None | None | False | None | False | 10159.302 | 0 | | 2897980 | 95015 | None | 1.1a8 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Plinth Beam) (I. No 2.5.2 P. No-16, Vol-1 of PWD Common SR 2023-24) | Cum | 10572.44 | 10572.44 | 1.95 | False | None | None | False | None | False | 20616.258 | 0 | | 2897981 | 95015 | None | 1.1a9 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Beams & Lintel) (I. No 2.5.2 P. No-16, Vol-1 of PWD Common SR 2023-24) | Cum | 11277.26 | 11277.26 | 2.31 | False | None | None | False | None | False | 26050.4706 | 0 | | 2897982 | 95015 | None | 1.1a10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Slab) (I. No 2.5.2 P. No-16, Vol-1 of PWD Common SR 2023-24) | Cum | 10572.44 | 10572.44 | 8.75 | False | None | None | False | None | False | 92508.85 | 0 | | 2897983 | 95015 | None | 1.1a11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Chajja)(I. No 2.5.1 P. No-16, Vol-1 of PWD Common SR 2023-24) | Cum | 9901.91 | 9901.91 | 0.54 | False | None | None | False | None | False | 5347.0314 | 0 | | 2897984 | 95015 | None | 1.1a12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.4.1, P, No. 15, Vol-1 of PWD Common SR 2023-24) | Cum | 6596.12 | 6596.12 | 2.17 | False | None | None | False | None | False | 14313.5804 | 0 | | 2897985 | 95015 | None | 1.1a13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(I. No. 2.11, P. No-18 , Vol-1 of PWD Common SR 2023-24) | t | 92140.71 | 92140.71 | 0.97 | False | None | None | False | None | False | 89376.4887 | 0 | | 2897986 | 95015 | None | 1.1a14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Ground Floor) (I. No 6.32, P. No-17 , Vol-2 of PWD Common SR 2023-24) | Sqm | 1349.3 | 1349.3 | 123.72 | False | None | None | False | None | False | 166935.396 | 0 | | 2897987 | 95015 | None | 1.1a15 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Terrace) (I. No 6.32, P. No-17 , Vol-2 of PWD Common SR 2023-24) | Sqm | 1362.79 | 1362.79 | 26.55 | False | None | None | False | None | False | 36182.0745 | 0 | | 2897988 | 95015 | None | 1.1a16 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (I. No 6.34, P. No-17 , Vol-2 of PWD Common SR 2023-24) | Sqm | 1137.12 | 1137.12 | 52.68 | False | None | None | False | None | False | 59903.4816 | 0 | | 2897989 | 95015 | None | 1.1a17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge External Wall Plastering (Ground Floor) (I. No 8.2.2, P. No-41 , Vol-2 of PWD Common SR 2023-24) | Sqm | 287.37 | 287.37 | 122.75 | False | None | None | False | None | False | 35274.6675 | 0 | | 2897990 | 95015 | None | 1.1a18 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge External Wall Plastering (Terrace) (I. No 8.2.2, P. No-41 , Vol-2 of PWD Common SR 2023-24) | Sqm | 290.24 | 290.24 | 61.54 | False | None | None | False | None | False | 17861.3696 | 0 | | 2897991 | 95015 | None | 1.1a19 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (I. No 8.1.2, P. No-41 , Vol-2 of PWD Common SR 2023-24) | Sqm | 248.23 | 248.23 | 234.8 | False | None | None | False | None | False | 58284.404 | 0 | | 2897992 | 95015 | None | 1.1a20 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Ceiling) (I. No 8.10, P. No-43, Vol-2 of PWD Common SR 2023-24) | Sqm | 217.33 | 217.33 | 57.23 | False | None | None | False | None | False | 12437.7959 | 0 | | 2897993 | 95015 | None | 1.1a21 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials,labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Daddoing (I. No 8.5.1, P. No-42 , Vol-2 of PWD Common SR 2023-24) | Sqm | 376.98 | 376.98 | 206.12 | False | None | None | False | None | False | 77703.1176 | 0 | | 2897994 | 95015 | None | 1.1a22 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall painting (Ground Floor) (I. No 8.30, P. No-45 , Vol-2 of PWD Common SR 2023-24) | Sqm | 179.22 | 179.22 | 122.75 | False | None | None | False | None | False | 21999.255 | 0 | | 2897995 | 95015 | None | 1.1a23 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall painting (Terrace) (I. No 8.28, P. No-45 , Vol-2 of PWD Common SR 2023-24) | Sqm | 181.01 | 181.01 | 61.54 | False | None | None | False | None | False | 11139.3554 | 0 | | 2897996 | 95015 | None | 1.1a24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal + Ceiling Painting) (I. No 8.51, P. No-50 , Vol-2 of PWD Common SR 2023-24) | Sqm | 103.0 | 103.0 | 57.23 | False | None | None | False | None | False | 5894.69 | 0 | | 2897997 | 95015 | None | 1.1a25 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.39, P. No-48 , Vol-2 of PWD Common SR 2023-24) | Sqm | 103.81 | 103.81 | 57.23 | False | None | None | False | None | False | 5941.0463 | 0 | | 2897998 | 95015 | None | 1.1a26 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Dark shade pigment using ordinary cement. (I. No 9.6.3, P. No-59 , Vol-2 of PWD Common SR 2023-24) | Sqm | 1155.66 | 1155.66 | 13.46 | False | None | None | False | None | False | 15555.1836 | 0 | | 2897999 | 95015 | None | 1.1a27 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. For Toilet Flooring (I. No 9.11, P. No-60 , Vol-2 of PWD Common SR 2023-24) | Sqm | 915.67 | 915.67 | 44.52 | False | None | None | False | None | False | 40765.6284 | 0 | | 2898000 | 95015 | None | 1.1a28 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. Toilet dadooing (I. No 10.14, P. No-71 , Vol-2 of PWD Common SR 2023-24) | Sqm | 1139.18 | 1139.18 | 111.62 | False | None | None | False | None | False | 127155.2716 | 0 | | 2898001 | 95015 | None | 1.1a29 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (I. No 11.34B P. No-86 , Vol-2 of PWD Common SR 2023-24) | Kgs | 188.49 | 188.49 | 103.32 | False | None | None | False | None | False | 19474.7868 | 0 | | 2898002 | 95015 | None | 1.1a30 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm 39mm with GI reinforcement of 1mm thickness Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm Maximum possible size 1000mm 1000mm The cost is inclusive of all fixtures and separate charges for minor T and Ps shall not be made (I. No 12.85 P. No-109 , Vol-2 of PWD Common SR 2023-24) | Sqm | 5890.57 | 5890.57 | 4.92 | False | None | None | False | None | False | 28981.6044 | 0 | | 2898003 | 95015 | None | 1.1a31 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) For Toilets (I. No 12.93.2, P.No.111, Vol-2 of PWD Common SR 2023-24) | m | 786.92 | 786.92 | 45.0 | False | None | None | False | None | False | 35411.4 | 0 | | 2898004 | 95015 | None | 1.1a32 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately) For Toilets (I. No 12.95, P.No.112 , Vol-2 of PWD Common SR 2023-24) | Sqm | 4543.33 | 4543.33 | 11.97 | False | None | None | False | None | False | 54383.6601 | 0 | | 2898005 | 95015 | None | 1.1a33 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, aking coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Terrace) (I. No 15.1, P. No-149 , Vol-2 of PWD Common SR 2023-24) | Sqm | 849.93 | 849.93 | 58.31 | False | None | None | False | None | False | 49559.4183 | 0 | | 2898006 | 95015 | None | 1.1a34 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 4983.14 | 4983.14 | 3.0 | False | None | None | False | None | False | 14949.42 | 0 | | 2898007 | 95015 | None | 1.1a35 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (I. No 14.1.1, P. No-131 , Vol-2 of PWD Common SR 2023-24) | Each | 5030.52 | 5030.52 | 3.0 | False | None | None | False | None | False | 15091.56 | 0 | | 2898008 | 95015 | None | 1.1a36 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively (I. No 14.23, P. No-135 , Vol-2 of PWD Common SR 2023-24) | Each | 1188.62 | 1188.62 | 5.0 | False | None | None | False | None | False | 5943.1 | 0 | | 2898009 | 95015 | None | 1.1a37 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (I. No 14.7.4, P. No-132 , Vol-2 of PWD Common SR 2023-24) | Each | 2415.35 | 2415.35 | 4.0 | False | None | None | False | None | False | 9661.4 | 0 | | 2898010 | 95015 | None | 1.1a38 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal parti tions by cutting a chase of appropriate width with chase cutter and embed ding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth (I. No 10.8 P. No-70 , Vol-2 of PWD Common SR 2023-24) | Sqm | 2872.67 | 2872.67 | 6.33 | False | None | None | False | None | False | 18184.0011 | 0 | | 2898011 | 95015 | None | 1.1a39 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 (I. No 13.53, P. No-126, Vol-2 of PWD Common SR 2023-24) | No | 5811.56 | 5811.56 | 2.0 | False | None | None | False | None | False | 11623.12 | 0 | | 2898012 | 95015 | None | 1.1a40 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for: PVC pipes 75mm dia., 6 kg/sqcm & Class 3. (I. No 10.1.5, P. No-113, Vol-5 of PWD Common WSSW SR 2023-24) | m | 165.83 | 165.83 | 70.0 | False | None | None | False | None | False | 11608.1 | 0 | | 2898013 | 95015 | None | 1.1a41 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete for: PVC pipes 110mm dia., 6 kg/sqcm & Class 3. (I. No 10.1.5, P. No-113, Vol-5 of PWD Common WSSW SR 2023-24) | m | 423.33 | 423.33 | 25.0 | False | None | None | False | None | False | 10583.25 | 0 | | 2898014 | 95015 | None | 1.1a42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes (I. No 13.32.1, P. No-122, Vol-2 of PWD Common SR 2023-24) | m | 318.27 | 318.27 | 25.0 | False | None | None | False | None | False | 7956.75 | 0 | | 2898015 | 95015 | None | 1.1a43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes (I. No 13.32.2, P. No-122, Vol-2 of PWD Common SR 2023-24) | m | 390.37 | 390.37 | 50.0 | False | None | None | False | None | False | 19518.5 | 0 | | 2898016 | 95015 | None | 1.1a44 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 25 mm nominal dia Pipes (I. No 13.33.3, P. No-122, Vol-2 of PWD Common SR 2023-24) | m | 304.88 | 304.88 | 15.0 | False | None | None | False | None | False | 4573.2 | 0 | | 2898017 | 95015 | None | 1.1a45 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 32 mm nominal dia Pipes (I. No 13.33.4, P. No-122, Vol-2 of PWD Common SR 2023-24) | m | 383.16 | 383.16 | 10.0 | False | None | None | False | None | False | 3831.6 | 0 | | 2898018 | 95015 | None | 1.1a46 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore (I. No 13.2.1 P. No-117 , Vol-2 of PWD Common SR 2023-24) | No | 294.58 | 294.58 | 20.0 | False | None | None | False | None | False | 5891.6 | 0 | | 2898019 | 95015 | None | 1.1a47 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore (I. No 13.3.1 P. No-117 , Vol-2 of PWD Common SR 2023-24) | No | 307.97 | 307.97 | 10.0 | False | None | None | False | None | False | 3079.7 | 0 | | 2898020 | 95015 | None | 1.1a48 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore (I. No 13.5.3 P. No-117 , Vol-2 of PWD Common SR 2023-24) | No | 341.96 | 341.96 | 1.0 | False | None | None | False | None | False | 341.96 | 0 | | 2898021 | 95015 | None | 1.1a49 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (I. No. 13.59, P. No. 127, Vol-2 of PWD Common SR 2023-24) | No | 226.6 | 226.6 | 15.0 | False | None | None | False | None | False | 3399.0 | 0 | | 2898022 | 95015 | None | 1.1a50 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (I. No. 13.58, P. No. 127, Vol-2 of PWD Common SR 2023-24) | No | 356.38 | 356.38 | 15.0 | False | None | None | False | None | False | 5345.7 | 0 | | 2898023 | 95015 | None | 1.1a51 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (terrace) (I. No. 13.34, P. No. 123, Vol-2 of PWD Common SR 2023-24) | l | 9.36 | 9.36 | 1000.0 | False | None | None | False | None | False | 9360.0 | 0 | | 2898024 | 95015 | None | 1.1a52 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (I. No. 2.1.1, P. No. 5 of 105, of PWD Ele SR 2023-24) | Point | 285.0 | 285.0 | 8.0 | False | None | None | False | None | False | 2280.0 | 0 | | 2898025 | 95015 | None | 1.1a53 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (I. No. 2.1.2, P. No. 5 of 105, of PWD Ele SR 2023-24) | Point | 394.0 | 394.0 | 8.0 | False | None | None | False | None | False | 3152.0 | 0 | | 2898026 | 95015 | None | 1.1a54 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (I. No. 2.1.3, P. No. 5 of 105, of PWD Ele SR 2023-24) | Point | 570.0 | 570.0 | 1.0 | False | None | None | False | None | False | 570.0 | 0 | | 2898027 | 95015 | None | 1.1a55 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (I. No. 2.1.4, P. No. 5 of 105, of PWD Ele SR 2023-24) | Point | 708.0 | 708.0 | 6.0 | False | None | None | False | None | False | 4248.0 | 0 | | 2898028 | 95015 | None | 1.1a56 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. (I. No. 2.1.5, P. No. 5 of 105, of PWD Ele SR 2023-24) | Point | 1035.0 | 1035.0 | 1.0 | False | None | None | False | None | False | 1035.0 | 0 | | 2898029 | 95015 | None | 1.1a57 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.1, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 138.0 | 138.0 | 10.0 | False | None | None | False | None | False | 1380.0 | 0 | | 2898030 | 95015 | None | 1.1a58 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.2, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 159.0 | 159.0 | 8.0 | False | None | None | False | None | False | 1272.0 | 0 | | 2898031 | 95015 | None | 1.1a59 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.3, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | | 2898032 | 95015 | None | 1.1a60 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.4, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 220.0 | 220.0 | 6.0 | False | None | None | False | None | False | 1320.0 | 0 | | 2898033 | 95015 | None | 1.1a61 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.5, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 261.0 | 261.0 | 4.0 | False | None | None | False | None | False | 1044.0 | 0 | | 2898034 | 95015 | None | 1.1a62 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.6, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | | 2898035 | 95015 | None | 1.1a63 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall (I. No 3.4.7, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 | | 2898036 | 95015 | None | 1.1a64 | Supplying and fixing PVC/metal conduit Deep junction box (I. No. 1.5.1, P. No. 2 of 105, of PWD Ele SR 2023-24) | Each | 49.0 | 49.0 | 10.0 | False | None | None | False | None | False | 490.0 | 0 | | 2898037 | 95015 | None | 1.1a65 | Supplying and fixing PVC/metal conduit Deep junction box (I. No. 1.5.2, P. No. 2 of 105, of PWD Ele SR 2023-24) | Each | 56.0 | 56.0 | 10.0 | False | None | None | False | None | False | 560.0 | 0 | | 2898038 | 95015 | None | 1.1a66 | Supplying and fixing PVC/metal conduit Deep junction box (I. No. 1.5.3, P. No. 2 of 105, of PWD Ele SR 2023-24) | Each | 61.0 | 61.0 | 4.0 | False | None | None | False | None | False | 244.0 | 0 | | 2898039 | 95015 | None | 1.1a67 | Supplying And Fixing Metal Fan Box with Round Hook (I. No 1.13, P. No. 8 of 105, of PWD Ele SR 2023-24) | No | 117.0 | 117.0 | 8.0 | False | None | None | False | None | False | 936.0 | 0 | | 2898040 | 95015 | None | 1.1a68 | Supplying and mounting 2 Nos. of 2Way 6 A flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 3854 (I. No 3.2, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 170.0 | 170.0 | 4.0 | False | None | None | False | None | False | 680.0 | 0 | | 2898041 | 95015 | None | 1.1a69 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.1, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 137.0 | 137.0 | 12.0 | False | None | None | False | None | False | 1644.0 | 0 | | 2898042 | 95015 | None | 1.1a70 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.2, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 161.0 | 161.0 | 8.0 | False | None | None | False | None | False | 1288.0 | 0 | | 2898043 | 95015 | None | 1.1a71 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.3, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 175.0 | 175.0 | 6.0 | False | None | None | False | None | False | 1050.0 | 0 | | 2898044 | 95015 | None | 1.1a72 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.4, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 234.0 | 234.0 | 10.0 | False | None | None | False | None | False | 2340.0 | 0 | | 2898045 | 95015 | None | 1.1a73 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.5, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 284.0 | 284.0 | 6.0 | False | None | None | False | None | False | 1704.0 | 0 | | 2898046 | 95015 | None | 1.1a74 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.6, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 344.0 | 344.0 | 4.0 | False | None | None | False | None | False | 1376.0 | 0 | | 2898047 | 95015 | None | 1.1a75 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (I. No 3.5.7, P. No. 8 of 105, of PWD Ele SR 2023-24) | Each | 397.0 | 397.0 | 2.0 | False | None | None | False | None | False | 794.0 | 0 | | 2898048 | 95015 | None | 1.1a76 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.1, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 102.0 | 102.0 | 10.0 | False | None | None | False | None | False | 1020.0 | 0 | | 2898049 | 95015 | None | 1.1a77 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.2, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 166.0 | 166.0 | 6.0 | False | None | None | False | None | False | 996.0 | 0 | | 2898050 | 95015 | None | 1.1a78 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.3, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 171.0 | 171.0 | 25.0 | False | None | None | False | None | False | 4275.0 | 0 | | 2898051 | 95015 | None | 1.1a79 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.4, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | | 2898052 | 95015 | None | 1.1a80 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.7, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 180.0 | 180.0 | 10.0 | False | None | None | False | None | False | 1800.0 | 0 | | 2898053 | 95015 | None | 1.1a81 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.10, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 | | 2898054 | 95015 | None | 1.1a82 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.11, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 156.0 | 156.0 | 6.0 | False | None | None | False | None | False | 936.0 | 0 | | 2898055 | 95015 | None | 1.1a83 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (I. No 3.6.12, P. No. 9 of 105, of PWD Ele SR 2023-24) | Each | 337.0 | 337.0 | 2.0 | False | None | None | False | None | False | 674.0 | 0 | | 2898056 | 95015 | None | 1.1a84 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (I. No 1.2.1, P. No. 2 of 105, of PWD Ele SR 2023-24) | m | 66.0 | 66.0 | 40.0 | False | None | None | False | None | False | 2640.0 | 0 | | 2898057 | 95015 | None | 1.1a85 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (I. No 1.2.2, P. No. 2 of 105, of PWD Ele SR 2023-24) | m | 78.0 | 78.0 | 25.0 | False | None | None | False | None | False | 1950.0 | 0 | | 2898058 | 95015 | None | 1.1a86 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary (I. No 1.2.3, P. No. 2 of 105, of PWD Ele SR 2023-24) | m | 103.0 | 103.0 | 10.0 | False | None | None | False | None | False | 1030.0 | 0 | | 2898059 | 95015 | None | 1.1a87 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (I. No 1.3.1, P. No. 2 of 105, of PWD Ele SR 2023-24) | m | 68.0 | 68.0 | 20.0 | False | None | None | False | None | False | 1360.0 | 0 | | 2898060 | 95015 | None | 1.1a88 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (I. No 1.3.2, P. No. 2 of 105, of PWD Ele SR 2023-24) | m | 79.0 | 79.0 | 15.0 | False | None | None | False | None | False | 1185.0 | 0 | | 2898061 | 95015 | None | 1.1a89 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (I. No 1.3.3, P. No. 2 of 105, of PWD Ele SR 2023-24) | m | 99.0 | 99.0 | 10.0 | False | None | None | False | None | False | 990.0 | 0 | | 2898062 | 95015 | None | 1.1a90 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 (I. No 2.3.2, P. No. 5 of 105, of PWD Ele SR 2023-24) | m | 26.0 | 26.0 | 40.0 | False | None | None | False | None | False | 1040.0 | 0 | | 2898063 | 95015 | None | 1.1a91 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 (I. No 2.3.3, P. No. 5 of 105, of PWD Ele SR 2023-24) | m | 42.0 | 42.0 | 30.0 | False | None | None | False | None | False | 1260.0 | 0 | | 2898064 | 95015 | None | 1.1a92 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 (I. No 2.3.4, P. No. 5 of 105, of PWD Ele SR 2023-24) | m | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 | | 2898065 | 95015 | None | 1.1a93 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 (I. No 2.3.5, P. No. 5 of 105, of PWD Ele SR 2023-24) | m | 92.0 | 92.0 | 10.0 | False | None | None | False | None | False | 920.0 | 0 | | 2898066 | 95015 | None | 1.1a94 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (I. No 5.19.9, P. No. 18 of 105, of PWD Ele SR 2023-24) | Each | 2329.0 | 2329.0 | 2.0 | False | None | None | False | None | False | 4658.0 | 0 | | 2898067 | 95015 | None | 1.1a95 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. (I. No 5.19.11, P. No. 18 of 105, of PWD Ele SR 2023-24) | Each | 4038.0 | 4038.0 | 2.0 | False | None | None | False | None | False | 8076.0 | 0 | | 2898068 | 95015 | None | 1.1a96 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. (I. No 5.20.4, P. No. 18 of 105, of PWD Ele SR 2023-24) | Each | 4559.0 | 4559.0 | 2.0 | False | None | None | False | None | False | 9118.0 | 0 | | 2898069 | 95015 | None | 1.1a97 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 0898. (I. No 5.18.1 P. No. 17 of 105, of PWD Ele SR 2023-24) | Each | 415.0 | 415.0 | 8.0 | False | None | None | False | None | False | 3320.0 | 0 | | 2898070 | 95015 | None | 1.1a98 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 0898. (I. No 5.18.4 P. No. 17 of 105, of PWD Ele SR 2023-24) | Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | | 2898071 | 95015 | None | 1.1a99 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 percent lumen maintenance with CRI less than 80 Power Input 220 to 240V 50 or 60Hz Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition (I. No 11.3.1, P. No. 43 of 105, of PWD Ele SR 2023-24) | Each | 551.0 | 551.0 | 10.0 | False | None | None | False | None | False | 5510.0 | 0 | | 2898072 | 95015 | None | 1.1a100 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours and 70 percent lumen maintenance with CRI less than 80 Power Input 220 to 240V 50 or 60Hz Power factor less than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition (I. No 11.3.2, P. No. 43 of 105, of PWD Ele SR 2023-24) | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | | 2898073 | 95015 | None | 1.1a101 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 percent lumen maintenance with CRI less than 80. Power Input: 220-240V at 50 or 60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition (I. No 11.5.1, P. No. 44 of 105, of PWD Ele SR 2023-24) | Each | 571.0 | 571.0 | 10.0 | False | None | None | False | None | False | 5710.0 | 0 | | 2898074 | 95015 | None | 1.1a102 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 percent lumen maintenance with CRI less than 80. Power Input: 220-240V at 50 or 60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition (I. No 11.5.2, P. No. 44 of 105, of PWD Ele SR 2023-24) | Each | 885.0 | 885.0 | 10.0 | False | None | None | False | None | False | 8850.0 | 0 | | 2898075 | 95015 | None | 1.1a103 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70 percent lumen maintenance with CRI less than 80. Power Input: 220-240V at 50 or 60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition (I. No 11.5.3, P. No. 44 of 105, of PWD Ele SR 2023-24) | Each | 1324.0 | 1324.0 | 10.0 | False | None | None | False | None | False | 13240.0 | 0 | | 2898076 | 95015 | None | 1.1a104 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. (I. No. 6.2.1, P. No. 30 of 105, of PWD Ele SR 2023-24) | Each | 2969.0 | 2969.0 | 4.0 | False | None | None | False | None | False | 11876.0 | 0 | | 2898077 | 95015 | None | 1.1a105 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (I. No. 5.42.1, P. No. 20 of 105, of PWD Ele SR 2023-24) | cm | 0.5 | 0.5 | 2500.0 | False | None | None | False | None | False | 1250.0 | 0 | | 2898078 | 95015 | None | 1.1a106 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (I. No. 5.42.2, P. No. 20 of 105, of PWD Ele SR 2023-24) | cm | 0.43 | 0.43 | 2000.0 | False | None | None | False | None | False | 860.0 | 0 | | 2898079 | 95015 | None | 1.1a107 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete (I. No. 5.40.1, P. No. 20 of 105, of PWD Ele SR 2023-24) | m | 2465.0 | 2465.0 | 1.0 | False | None | None | False | None | False | 2465.0 | 0 | | 2898080 | 95015 | None | 1.1a108 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag (I. No. 51.01, P. No. 22 of 81, of ESCOM SR 2023-24) | No | 743.0 | 743.0 | 2.0 | False | None | None | False | None | False | 1486.0 | 0 | | 2898081 | 95015 | None | 1.1a109 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag (I. No. 51.02, P. No. 22 of 81, of ESCOM SR 2023-24) | No | 676.0 | 676.0 | 2.0 | False | None | None | False | None | False | 1352.0 | 0 | | 2898082 | 95015 | None | 1.1a110 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag (I. No. 51.03, P. No. 22 of 81, of ESCOM SR 2023-24) | Bag | 310.0 | 310.0 | 4.0 | False | None | None | False | None | False | 1240.0 | 0 | | 2898083 | 95015 | None | 1.1a111 | Digging of Pit for providing GI Pipe type Earthing. Ordinary Soil (I. No. 1.6, P. No. 43 of 81, of ESCOM SR 2023-24) | Per Pit | 759.0 | 759.0 | 2.0 | False | None | None | False | None | False | 1518.0 | 0 |
|