createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709555607030
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee900.00
emd72000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-03-2024 17:30:00
tenderQueryClose12-03-2024 16:00:00
technicalBidOpen14-03-2024 11:30:00
publishedDate04-03-2024 18:26:56
publishedByPostTP_CO_KDK
publishedByUserKPE15278 - DEEPA H R
bidValidityPeriod90
noOfCalls2
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonJUNIOR ENGINEER
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8105479629
tenderSupplierListNone
tenderSchedule
createdTs1709555607033
version11
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/OW/WORK_INDENT14015/CALL-2
titleConstruction of compound required for construction of Indira canteen in APMC market premises of Bandipalya village and installation of interlocking, installation of CCTV camera and provision of infrastructure in Kadakola Town Panchayath
descriptionConstruction of compound required for construction of Indira canteen in APMC market premises of Bandipalya village and installation of interlocking, installation of CCTV camera and provision of infrastructure in Kadakola Town Panchayath
categoryWORKS
categoryTextWorks
ecv3600000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2455
locationNameDMA Town Panchayat Kadakola
provisionalAmount3600000.0
groupOverheadTotal592664.53
fileNumberKDKL/INDIRA/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17095556070000NoneNoneOther WorksConstruction of compound required for construction of Indira canteen in APMC market premises of Bandipalya village and installation of interlocking, installation of CCTV camera and provision of infrastructure in Kadakola Town Panchayath3007335.47
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
291264795586Nonecode01Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. (PWD Comman SR Vol-1, 2023-24, Item no. 1.17.1, Page No.10)Cum269.86269.86179.95FalseNoneNoneFalseNoneFalse48561.3070
291264895586Nonecode02Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD SR Vol-01, 2023-24, Item no. 2.1.2, Page No.15)Cum5833.925833.9246.5335FalseNoneNoneFalseNoneFalse271472.716320
291264995586Nonecode03Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.2, Page No.9)Cum6816.546816.5449.28FalseNoneNoneFalseNoneFalse335919.09120
291265095586Nonecode04Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.4, Page No.9)Cum6580.676580.6722.14FalseNoneNoneFalseNoneFalse145696.03380
291265195586Nonecode05Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge (PWD SR Vol-02, 2023-24, Item no.8.19.1, Page No.44)Cum262.65262.6598.3999FalseNoneNoneFalseNoneFalse25844.7337350
291265295586Nonecode06Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD Vol-1 SR 2023-24, Item No. 2.11a, Page No. 18)Tonne92140.7192140.711.1653FalseNoneNoneFalseNoneFalse107371.5693630
291265395586Nonecode07Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Foundation, Sub structure of Cross drainages (PWD SR, Vol.1, 2023-24, Item no. 2.4.3, Page No.16)Cum6842.886842.885.535FalseNoneNoneFalseNoneFalse37875.34080
291265495586Nonecode08Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Cement Concrete Drain Walls (PWD SR, Vol.1, 2023-24, Item no. 2.4.3, Page No.16)Cum8743.688743.6820.9485FalseNoneNoneFalseNoneFalse183166.980480
291265595586Nonecode09Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (PWD Vol-1 SR 2023-24, Item no. 1.10, Page No.7)Cum164.8164.868.52FalseNoneNoneFalseNoneFalse11292.0960
291265695586Nonecode10Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work (PWD SR Vol 3, 2023-24, Item no. 3.1, Page No.17)Cum87.5587.55111.43FalseNoneNoneFalseNoneFalse9755.69650
291265795586Nonecode11Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD Vol-2 SR 2023-24, Item no. 11.25.2, Page No.84)Kg140.08140.086322.5FalseNoneNoneFalseNoneFalse885655.80
291265895586Nonecode12Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD Vol-2 SR 2023-24, Item no. 11.16.2, Page No.82)Kg140.08140.08966.735FalseNoneNoneFalseNoneFalse135420.23880
291265995586Nonecode13Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.33, Page No.47)Sqm143.17143.17135.0FalseNoneNoneFalseNoneFalse19327.950
291266095586Nonecode14Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification) (PWD SR Vol-03, 2023-24, Item no. 6.8.2, Page No.51)Sqm1100.041100.04388.795FalseNoneNoneFalseNoneFalse427690.05180
291266195586Nonecode15Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) (PWD SR Vol-03, 2023-24, Item no. 6.8.2, Page No.51)m1100.041100.0451.2FalseNoneNoneFalseNoneFalse56322.0480
291266295586Nonecode16Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.33.1, Page No.46)Sqm162.74162.74175.6199FalseNoneNoneFalseNoneFalse28580.3825260
291266395586Nonecode17Procurement of Ingredients: Procuremen of farm yard manure/compost, sandandred-earth (ingredients) required forraising seedlings inclusive of transportation, breaking of clods, sieving and heaping eaching redient separately at nursery site Fine coarse Red-earth/soil (Ceiling rate) (PWD SR Vol-08, 2022-23, Item no. 1.2, Page No.1)Cum555.35555.3523.04FalseNoneNoneFalseNoneFalse12795.2640
291266495586Nonecode18Procurement of quality lawn grass, Mexican Grass Turf (PWD SR Vol-08, 2022-23, Item no. 12.10 G(c), Page No.49)Cum206.0206.051.2FalseNoneNoneFalseNoneFalse10547.20
291266595586Nonecode19Labour Charges: mixing Input s as per prescribed proportion and quantity and spreading, applying fertilizers, digging, levelling, and dibbling with lawn grass at a spacing of 5cmx5cm & as per the direction of the Officer in charge of the work., Mexican Grass Turf (PWD SR Vol-08, 2022-23, Item no. 12.10 H(c), Page No.50)Cum602.55602.5551.2FalseNoneNoneFalseNoneFalse30850.560
291266695586Nonecode20Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 600X850 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. (PWD SR Vol-02, 2023-24, Item No.13.55 Page No.127)Each7623.037623.032.0FalseNoneNoneFalseNoneFalse15246.060
291266795586Nonecode21Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5. (PWD SR Vol-05, 2023-24, l no. 10.1.2, Page No.113)m69.0169.01120.0FalseNoneNoneFalseNoneFalse8281.20
291266895586Nonecode22Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. (PWD SR Vol-05, 2023-24, l no. 10.2.4, Page No.114)m593.28593.2840.0FalseNoneNoneFalseNoneFalse23731.20
291266995586Nonecode23Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.32mm dia PVC couplers, (PWD SR Vol-05, 2023-24, ltem no.10.8.2, Page No.116)Each16.4816.4810.0FalseNoneNoneFalseNoneFalse164.80
291267095586Nonecode24Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Elbows. (PWD SR Vol-05, 2023-24, ltem no. 10.9.2, Page No.117)Each21.6321.6315.0FalseNoneNoneFalseNoneFalse324.450
291267195586Nonecode25Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC BEND. (PWD SR Vol-05, 2023-24, ltem no. 10.11.2, Page No.118)Each37.0837.086.0FalseNoneNoneFalseNoneFalse222.480
291267295586Nonecode26Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately.(For 1000 litre capacity) (PWD SR Vol-02, 2023-24, Sl no. 13.34A, Page No.123)l9.279.271000.0FalseNoneNoneFalseNoneFalse9270.00
291267395586Nonecode27Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.4.2, Page No.117)Nos.615.94615.942.0FalseNoneNoneFalseNoneFalse1231.880
291267495586Nonecode28Providing and fixing brass stop cock of approved quality : 20 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.3.2, Page No.117)Nos.314.15314.154.0FalseNoneNoneFalseNoneFalse1256.60
291267595586Nonecode29Providing and fixing brass bib cock of approved quality.20 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.2.2, Page No.117)Nos.314.15314.154.0FalseNoneNoneFalseNoneFalse1256.60
291267695586Nonecode30Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 19/20 mm dia 2 mm thick, (PWD Electrical CSR 2023-24, IN-1.2.1, PN-2)Mtr67.9867.9820.0FalseNoneNoneFalseNoneFalse1359.60
291267795586Nonecode31Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.2.2, PN-2),Mtr80.3480.3455.0FalseNoneNoneFalseNoneFalse4418.70
291267895586Nonecode32Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.3.1, PN-2),Mtr70.0470.0410.0FalseNoneNoneFalseNoneFalse700.40
291267995586Nonecode33Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.3.2, PN-2)Mtr81.3781.3720.0FalseNoneNoneFalseNoneFalse1627.40
291268095586Nonecode34Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2021-2022, IN-2.2.1, PN-5), Short point upto 3m from tapping point to out let via switch box.Mtr277.07277.072.0FalseNoneNoneFalseNoneFalse554.140
291268195586Nonecode35Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Medium point above 3m upto 6m from tapping point to out let via switch box.Point390.37390.376.0FalseNoneNoneFalseNoneFalse2342.220
291268295586Nonecode36Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Long point above 6m upto 10m from tapping point to out let via switch boxPoint571.65571.6516.0FalseNoneNoneFalseNoneFalse9146.40
291268395586Nonecode37Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.2, PN-5), 1.5 mSqmMtr26.7826.7820.0FalseNoneNoneFalseNoneFalse535.60
291268495586Nonecode38Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.3, PN-5), 2.5 mSqmMtr43.2643.2620.0FalseNoneNoneFalseNoneFalse865.20
291268595586Nonecode39Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. (PWD Electrical CSR 2023-24, IN-2.3.4, PN-5), 4 mSqmMtr64.8964.8945.0FalseNoneNoneFalseNoneFalse2920.050
291268695586Nonecode40Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, (PWD Electrical CSR 2023-24, IN-3.1.2, PN-8), 6A 3/5 WayEach151.41151.414.0FalseNoneNoneFalseNoneFalse605.640
291268795586Nonecode41Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. (PWD Electrical CSR 2023-24, IN-6.3.3, PN-9), 6A Three Way socket.Each176.13176.1314.0FalseNoneNoneFalseNoneFalse2465.820
291268895586Nonecode42Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (PWD Electrical CSR 2023-24, IN-3.4.3, PN-8), 6 WayEach182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
291268995586Nonecode43Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (PWD Electrical CSR 2023-24, IN-3.4.6, PN-8), 16-18 WayEach328.57328.572.0FalseNoneNoneFalseNoneFalse657.140
291269095586Nonecode44Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.3, PN-8), 6 ModuleEach180.25180.251.0FalseNoneNoneFalseNoneFalse180.250
291269195586Nonecode45Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.7, PN-8), 16 ModuleEach408.91408.912.0FalseNoneNoneFalseNoneFalse817.820
291269295586Nonecode46Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCTgreater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminairegreater than IK08. Power Factorgreater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED fficiency greaterthan1301m/w, nominal CRIgreater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned.Note : 3) LED street lights that is procured, shall comply to the specification as per DMA Order(No. 25775DMA 69 DEVT 2018-19 Dated : 03-01-2019 ).(PWD Electrical CSR 2023-24, IN-11.8.1, PN-46), LED Streetlight 25 WEach2497.752497.751.0FalseNoneNoneFalseNoneFalse2497.750
291269395586Nonecode47Supplying and Fixing........mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.(PWD Electrical CSR 2023-24, IN-13.2.1, PN-56), Using 25mm dia G.I.PipeEach1239.091239.091.0FalseNoneNoneFalseNoneFalse1239.090
291269495586Nonecode48Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. (PWD Electrical CSR 2023-24, IN-13.5, PN-56)Each166.86166.861.0FalseNoneNoneFalseNoneFalse166.860
291269595586Nonecode49Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRIgreater than 80. Power Input: 220-240V@ 50/60Hz & Power factorgreater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4'-20/22 W, (PWD Electrical CSR 2023-24, IN-11.3.2, PN-43)Each710.7710.78.0FalseNoneNoneFalseNoneFalse5685.60
291269695586Nonecode50Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI greater than 70%. efficacygreater than100 lumen per W, 120degree beam spread, life greater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PFgreater than 0.95, power loss shouldless than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W (PWD Electrical CSR 2023-24, IN-11.4.2, PN-44)Each1307.071307.074.0FalseNoneNoneFalseNoneFalse5228.280
291269795586Nonecode51Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling /rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders. (PWD Electrical CSR 2023-2024, IN-13.7.1, PN-56)Each125.66125.6610.0FalseNoneNoneFalseNoneFalse1256.60
291269895586Nonecode52Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. (PWD Electrical CSR 2023-24, IN-3.14.6, PN-10), 6A Lamp HolderNo73.1373.136.0FalseNoneNoneFalseNoneFalse438.780
291269995586Nonecode53Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (PWD Electrical CSR 2023-24, IN-6.1, PN-30).Each1536.761536.766.0FalseNoneNoneFalseNoneFalse9220.560
291270095586Nonecode54Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.. (PWD Electrical CSR 2023-24, IN-13.13, PN-57)Each728.21728.216.0FalseNoneNoneFalseNoneFalse4369.260
291270195586Nonecode55Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (PWD Electrical CSR 2023-24, IN-5.18.4, PN-17).6-32 A DPEach761.17761.172.0FalseNoneNoneFalseNoneFalse1522.340
291270295586Nonecode56Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (PWD Electrical CSR 2023-24, IN-5.42.2, PN-20).16SWG.Sq CM0.440.448000.0FalseNoneNoneFalseNoneFalse3520.00
291270395586Nonecode57Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. (PWD Electrical CSR 2023-24, IN-5.40.1, PN-20).100 A 4 x 30 x 6 mm Aluminium StripsMtr2538.952538.951.0FalseNoneNoneFalseNoneFalse2538.950
291270495586Nonecode58Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter (PWD Electrical CSR 2023-24, IN-5.30, PN-19)Each1421.41421.41.0FalseNoneNoneFalseNoneFalse1421.40
291270595586Nonecode59Digging of Pit for providing GI Pipe type Earthing, Hard Soil, (Bescom CSR 2023-24, IN-1.6.2, PN-43)Per Pit3079.73079.71.0FalseNoneNoneFalseNoneFalse3079.70
291270695586Nonecode60GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg, (Bescom CSR 2021-22, IN-54.01, PN-17(Part-III))Nos.765.29765.291.0FalseNoneNoneFalseNoneFalse765.290
291270795586Nonecode61Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each, (Bescom CSR 2023-24, IN-51.02, PN-22)Nos.696.28696.281.0FalseNoneNoneFalseNoneFalse696.280
291270895586Nonecode62Good Quality Salt for grounding purposes packed in 50 Kg gunny bag, (Bescom CSR 2023-24, IN-51.03, PN-22)Nos.319.3319.31.0FalseNoneNoneFalseNoneFalse319.30
291270995586Nonecode631.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, (Bescom CSR 2023-24, IN-32.03, PN-13), 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km121544.12121544.120.06FalseNoneNoneFalseNoneFalse7292.64720
291271095586Nonecode64Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable, (Bescom CSR 2023-24, IN-21.05, PN-52), 2.5 to 25 SqmmKm21512.5821512.580.06FalseNoneNoneFalseNoneFalse1290.75480
291271195586Nonecode65Aluminium End Terminal (Lug), 25 Sqmm (Bescom CSR 2023-24, IN-60.03, PN-27)Each3.093.098.0FalseNoneNoneFalseNoneFalse24.720
291271295586Nonecode66GI Pipe B - Class as per IS-1239, (Bescom CSR 2023-24, IN-49.04, PN-16(Part-III)), GI Pipe - 40 mm DiaMtr303.85303.854.0FalseNoneNoneFalseNoneFalse1215.40
291271395586Nonecode67Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable, (Bescom CSR 2021-22, IN-35.01, PN-15), Up to 4C x 50 SqmmSet333.72333.721.0FalseNoneNoneFalseNoneFalse333.720
291271495586Nonecode68Supply, delivery, erection and commissioning at site ELCB suitable for monoblock centrifugal pump confirming with ISI mark and its latest amendments. (PWD SR Vol-05, 2023-24, Item No.13.45, Page No.158)Set4623.514623.511.0FalseNoneNoneFalseNoneFalse4623.510
291271595586Nonecode69Fixed Camera Specifications-Lens type-Bi-focal auto iris with 10x digital zoom Mode-Day/Night Image size-720x486 (NTSC), Streaming-High speed,Weather Proof-IP 66 compliant, Network Protocol-TCP/IP should be compliant of any other protocol required, Connectivity Cat 6 / Optical fibre, Ethernet-10Base-t/100Base-TX(RJ45),Power source-both self powered and externally powered (PWD SR Vol 04, 2023-24, Item No.34.2, Page No.52)Set12346.6112346.616.0FalseNoneNoneFalseNoneFalse74079.660
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17095556070000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17095556070000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17095556070000NoneNoneELIGIBILITYThe authority reserves right to accept or reject of all tenders without giving any reasonsNone
17095556070000NoneNoneELIGIBILITYBidder should be Pay Difference amount in the name Chief Officer, Town Panchayath, KadakolaNone
17095556070000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW-2None
17095556070000NoneNoneELIGIBILITYBIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneBIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHED
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual turnover certificate and balance sheetTrueTechnical Bid
Class III and above KPWD contractor registration certificateTrueTechnical Bid
Similar Work done certificate issued by not below the rank of Executive EngineerTrueTechnical Bid
Line of Credit -Conditional line of credit will not be accepted and it will be directly rejected and tender will not be acceptedTrueTechnical Bid
Minimum quantities work done certificateTrueTechnical Bid
BIDDER SHOULD UPLOAD ALL RELEVANT TECHNICAL DOCUMENTS AS PER CONDITIONS MENTIONED IN THE TENDER DOCUMENT ATTACHEDFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone