| 1709628381000 | 0 | None | None | Other Works | Construction of toilet for Hadicap at various department (5 Percentage) in wadi town. | 487228.21 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2919172 | 96113 | None | code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. In area of light jungle | Sqm | 412.65 | 412.65 | 0.148 | False | None | None | False | None | False | 61.0722 | 0 | | 2919173 | 96113 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 15.66 | False | None | None | False | None | False | 1677.186 | 0 | | 2919174 | 96113 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 1.044 | False | None | None | False | None | False | 6208.8768 | 0 | | 2919175 | 96113 | None | code04 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6948.9 | 6948.9 | 5.64 | False | None | None | False | None | False | 39191.796 | 0 | | 2919176 | 96113 | None | code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.92 | False | None | None | False | None | False | 13366.08 | 0 | | 2919177 | 96113 | None | code06 | Appendix I Additionalities for Formwork, Centering & Scaffolding Beams & Lintels of Building | Cum | 4176.9 | 4176.9 | 1.92 | False | None | None | False | None | False | 8019.648 | 0 | | 2919178 | 96113 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 2.12 | False | None | None | False | None | False | 14758.38 | 0 | | 2919179 | 96113 | None | code08 | Appendix I Additionalities for Formwork, Centering & ScaffoldingRoof (Straight & Arched) | Cum | 3480.75 | 3480.75 | 2.12 | False | None | None | False | None | False | 7379.19 | 0 | | 2919180 | 96113 | None | code09 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 0.57 | False | None | None | False | None | False | 53540.0145 | 0 | | 2919181 | 96113 | None | code10 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8621.55 | 8621.55 | 11.87 | False | None | None | False | None | False | 102337.7985 | 0 | | 2919182 | 96113 | None | code11 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 0.095 | False | None | None | False | None | False | 12389.1495 | 0 | | 2919183 | 96113 | None | code12 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Mtr | 333.9 | 333.9 | 34.2 | False | None | None | False | None | False | 11419.38 | 0 | | 2919184 | 96113 | None | code13 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges do- with one side prelam | Sqm | 2142.0 | 2142.0 | 9.45 | False | None | None | False | None | False | 20241.9 | 0 | | 2919185 | 96113 | None | code14 | Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 111.3 | 111.3 | 34.02 | False | None | None | False | None | False | 3786.426 | 0 | | 2919186 | 96113 | None | code15 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 253.05 | 253.05 | 8.64 | False | None | None | False | None | False | 2186.352 | 0 | | 2919187 | 96113 | None | code16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 137.49 | False | None | None | False | None | False | 53559.2295 | 0 | | 2919188 | 96113 | None | code17 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 7.43 | False | None | None | False | None | False | 6935.5335 | 0 | | 2919189 | 96113 | None | code18 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) | Sqm | 165.9 | 165.9 | 60.93 | False | None | None | False | None | False | 10108.287 | 0 | | 2919190 | 96113 | None | code19 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 65.49 | False | None | None | False | None | False | 19460.3535 | 0 | | 2919191 | 96113 | None | code20 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : | Each | 6275.85 | 6275.85 | 6.0 | False | None | None | False | None | False | 37655.1 | 0 | | 2919192 | 96113 | None | code21 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 431.55 | 431.55 | 60.0 | False | None | None | False | None | False | 25893.0 | 0 | | 2919193 | 96113 | None | code22 | Providing and fixing unplasticised PVC connection pipe with brass unions :20 mm nominal bore | No | 115.5 | 115.5 | 15.0 | False | None | None | False | None | False | 1732.5 | 0 | | 2919194 | 96113 | None | code23 | Providing and fixing brass bib cock of approved quality 20 mm nominal bor | No | 320.25 | 320.25 | 6.0 | False | None | None | False | None | False | 1921.5 | 0 | | 2919195 | 96113 | None | code24 | Providing and fixing brass stop cock of approved quality : 20 mm nominal bore | No | 320.25 | 320.25 | 6.0 | False | None | None | False | None | False | 1921.5 | 0 | | 2919196 | 96113 | None | code25 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thick | Mtr | 81.9 | 81.9 | 30.0 | False | None | None | False | None | False | 2457.0 | 0 | | 2919197 | 96113 | None | code26 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25 mm dia 2 mm thick | Mtr | 82.95 | 82.95 | 75.0 | False | None | None | False | None | False | 6221.25 | 0 | | 2919198 | 96113 | None | code27 | Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction box | Each | 58.8 | 58.8 | 6.0 | False | None | None | False | None | False | 352.8 | 0 | | 2919199 | 96113 | None | code28 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.10" x 7" x 3" (254 x 178 x 76 mm) | Each | 117.6 | 117.6 | 6.0 | False | None | None | False | None | False | 705.6 | 0 | | 2919200 | 96113 | None | code29 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of 6C x 1.5 mm2 | Mtr | 127.05 | 127.05 | 150.0 | False | None | None | False | None | False | 19057.5 | 0 | | 2919201 | 96113 | None | code30 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70Percentage. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should Lesser than 5Percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.18W, 6500K
| Each | 447.3 | 447.3 | 6.0 | False | None | None | False | None | False | 2683.8 | 0 |
|