1709643771000 | 0 | None | None | Water supply/sewage lines | Drilling of borewell, installation of motor and construction of cistern tank in ward no 1 to 39 of Ballari city corporation limits for the coming summer. | 8474568.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2927030 | 96500 | None | code01 | Providing, Single Phase Submersible Pump Sets of 100mm dia 4 inch suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. KUWS &BWSSB SOR vol-5 ,2023-24 item no. 13.6.3 for 12 stage page no 149 1.00 HP 0.75KW, 12 stag | No | 15241.8 | 15241.8 | 72.0 | False | None | None | False | None | False | 1097409.6 | 0 | 2927031 | 96500 | None | code02 | Providing, Single Phase Submersible Pump Sets of 100mm dia 4 inch suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. KUWS &BWSSB SOR vol-5 ,2023-24 item no. 13.6.3 for 12 stage page no 149 2.00 HP 1.5KW | No | 18498.9 | 18498.9 | 6.0 | False | None | None | False | None | False | 110993.4 | 0 | 2927032 | 96500 | None | code03 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13 8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694 2010. PWD Electrical SR 2023-24, Vol-6, It.No 2.5.8, P.No.6 of 108 3C x 2.5 mm2 | m | 118.65 | 118.65 | 6500.0 | False | None | None | False | None | False | 771225.0 | 0 | 2927033 | 96500 | None | code04 | Supply and delivery at site brand new best make starter control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments. Vol-5 SR 2023-24, CHAPTER 15, item No.13.43.1P.No.157, Upto 7.5 HP centrifugal pump | m | 9975.0 | 9975.0 | 78.0 | False | None | None | False | None | False | 778050.0 | 0 | 2927034 | 96500 | None | code05 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc, complete as per specification, with testing of as per instructions of engineer incharge of work. Vol-5 SR 2023-24, CHAPTER - 15, item No.13.34, P.No.156, Upto 7.5 HP centrifugal pump | No | 1522.5 | 1522.5 | 78.0 | False | None | None | False | None | False | 118755.0 | 0 | 2927035 | 96500 | None | code06 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834 1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. Vol-5 SR 2023-24, CHAPTER -15, item 13.25 .P.No.155 | Kvar | 577.5 | 577.5 | 78.0 | False | None | None | False | None | False | 45045.0 | 0 | 2927036 | 96500 | None | code07 | Supply and delivery at site delivery of best indigenous brand new MCB Miniature Circuit Breakers of required capacity as per IS 88228 1978 and its latest amendments and with ISI Mark of 6 10 16 20 25 40 Amps with scalable box. Vol-5 SR 2023-24, CHAPTER - 15, item No.13.26, P.No.155 Per 3Poles Rs 1312.5 | No | 1207.5 | 1207.5 | 78.0 | False | None | None | False | None | False | 94185.0 | 0 | 2927037 | 96500 | None | code08 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. Vol-5 SR 2023-24, CHAPTER - 15, item No.13.35.2, P.No.156 3.5X6sq.mm | m | 168.0 | 168.0 | 780.0 | False | None | None | False | None | False | 131040.0 | 0 | 2927038 | 96500 | None | code09 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. Note Upto 110mm dia Coil shall be used. For Grade PE80 PN.10 Vol-5 SR 2023-24, It.No.9.3.1 P.No.96 HDPE Grade PE80-PN10,63mm dia | m | 264.6 | 264.6 | 5850.0 | False | None | None | False | None | False | 1547910.0 | 0 | 2927039 | 96500 | None | code10 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata., Vol1 PWD SR 2031-24 page no10. item no 1.17.1 part-II | Cum | 275.1 | 275.1 | 40.5 | False | None | None | False | None | False | 11141.55 | 0 | 2927040 | 96500 | None | code11 | Cutting Asphalt Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner.KUWS &BWSSB Common volume 5 SR2023-24 item no 3.3 page no.48 | Cum | 1214.85 | 1214.85 | 20.25 | False | None | None | False | None | False | 24600.7125 | 0 | 2927041 | 96500 | None | code12 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement formwork to be paid separately PWD common SR 2023-24 Vol-1 item no.2.2.2.2 page no 15 Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates for PCC Couping for restoration | Cum | 6797.7 | 6797.7 | 47.325 | False | None | None | False | None | False | 321701.1525 | 0 | 2927042 | 96500 | None | code13 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1 6 12 1 cement 6 coarse sand 12 graded stone aggregate 20 mm nominal size upto plinth level with Cement mortar 1 6 1 cement 6 coarse sand, Building SR 2023-24, It.No.5.1.1, P.No.9 | Cum | 5891.55 | 5891.55 | 52.65 | False | None | None | False | None | False | 310190.1075 | 0 | 2927043 | 96500 | None | code14 | Providing Size Stone masonry with hard stone in foundation plinth with Cement mortar 1 6 1 cement 6 coarse sand Building SR 2023-24, It.No.5.4, P.No.9, | Cum | 6708.45 | 6708.45 | 52.65 | False | None | None | False | None | False | 353199.8925 | 0 | 2927044 | 96500 | None | code15 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Vol-5 SR 2021-22, CHAPTER - 15, item No.13.25.1, P.No.154, Size 50 mm | No | 1312.5 | 1312.5 | 78.0 | False | None | None | False | None | False | 102375.0 | 0 | 2927045 | 96500 | None | code16 | Brassbib-cock20mmdia Vol-5 SR 2021-22, CHAPTER - 15, item No.87, P.No.A-14, Size 20 | No | 183.75 | 183.75 | 156.0 | False | None | None | False | None | False | 28665.0 | 0 | 2927046 | 96500 | None | code17 | RCC hume pipe Circular pump house: Supplying precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm height of 2.5 Mtr. With Wall thickness 65mm. Vol-5 SR 2023-24, item No.10.6, P.No.116 | No | 17221.05 | 17221.05 | 39.0 | False | None | None | False | None | False | 671620.95 | 0 | 2927047 | 96500 | None | code18 | Erection and positioning of RCC Hume pipe pump house Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc,complete as directed by the Engineer in charge of the work. Vol-5 SR 2023-24, item No.10.7P.No.116 | No | 1976.1 | 1976.1 | 39.0 | False | None | None | False | None | False | 77067.9 | 0 | 2927048 | 96500 | None | code19 | Refilling the basement and pipe line trenches with selected avialable earth from trenches excavation including watering, consolidation in the layer of 15 cm thick included deposing the surplus earth all lead and lifts PWD SR 2021-22 item part II 1.10 page no 7 | Cum | 168.0 | 168.0 | 30.0 | False | None | None | False | None | False | 5040.0 | 0 | 2927049 | 96500 | None | code20 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. Vol-5 SR 2023-24, C item No.13.32, P.No.156 | No | 6825.0 | 6825.0 | 78.0 | False | None | None | False | None | False | 532350.0 | 0 | 2927050 | 96500 | None | code21 | Earthing Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Vol-5 SR 2023-24, item No.13.39 P.No.157 | No | 3937.5 | 3937.5 | 39.0 | False | None | None | False | None | False | 153562.5 | 0 | 2927051 | 96500 | None | code22 | Providing, Laying and Fixing GI pipes conforming to IS 1239 1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For Heavy Duty GI pipe. Vol-5 SR 2023-24, P.No.127 1 item no. 11.3.2,11.3.4,11.3.6 Heavy Duty GI pipe of 40mm dia | Mtr | 522.9 | 522.9 | 1560.0 | False | None | None | False | None | False | 815724.0 | 0 | 2927052 | 96500 | None | code23 | Providing, Laying and Fixing GI pipes conforming to IS 1239 1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For Heavy Duty GI pipe. Vol-5 SR 2023-24, P.No.127 1 item no. 11.3.2,11.3.4,11.3.6 Heavy Duty GI pipe of 25mm dia | Mtr | 376.95 | 376.95 | 320.0 | False | None | None | False | None | False | 120624.0 | 0 | 2927053 | 96500 | None | code24 | Providing, Laying and Fixing GI pipes conforming to IS 1239 1990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing For Heavy Duty GI pipe. Vol-5 SR 2023-24, P.No.127 1 item no. 11.3.2,11.3.4,11.3.6 Heavy Duty GI pipe of 20mm dia | Mtr | 276.15 | 276.15 | 300.0 | False | None | None | False | None | False | 82845.0 | 0 | 2927054 | 96500 | None | code25 | Providing wrought mild steel galvanized GI collar confirming to IS 1239-II, 1991 with latest amendments if any.Vol-5 SR 2023-24, P.No.129 1 item no. 11.6.2,11.6.4,11.6.6 For 20 mm dia GI collar | No | 103.95 | 103.95 | 200.0 | False | None | None | False | None | False | 20790.0 | 0 | 2927055 | 96500 | None | code26 | Providing wrought mild steel galvanized GI collar confirming to IS 1239-II, 1991 with latest amendments if any.Vol-5 SR 2023-24, P.No.129 1 item no. 11.6.2,11.6.4,11.6.6 For 25 mm dia GI collar | No | 148.05 | 148.05 | 60.0 | False | None | None | False | None | False | 8883.0 | 0 | 2927056 | 96500 | None | code27 | Providing wrought mild steel galvanized GI collar confirming to IS 1239-II, 1991 with latest amendments if any.Vol-5 SR 2023-24, P.No.129 1 item no. 11.6.2,11.6.4,11.6.6 For 40 mm dia GI collar | No | 216.3 | 216.3 | 260.0 | False | None | None | False | None | False | 56238.0 | 0 | 2927057 | 96500 | None | code28 | Supply and delivery at site wrought middle steel galvanized GI tee confirming to IS 1239-II, 1991 with latest amendments if any.KUWS &BWSSB Common SR 2023-24 page no 130 item no11.9.3 Heavy Duty GI pipe of 25mm dia Tee | No | 144.9 | 144.9 | 160.0 | False | None | None | False | None | False | 23184.0 | 0 | 2927058 | 96500 | None | code29 | Supply and delivery at site wrought middle steel galvanized GI tee confirming to IS 1239-II, 1991 with latest amendments if any.KUWS &BWSSB Common SR 2023-24 page no 130 item no11.9.3 Heavy Duty GI pipe of 40mm dia Tee | No | 199.5 | 199.5 | 80.0 | False | None | None | False | None | False | 15960.0 | 0 | 2927059 | 96500 | None | code30 | Supply and delivery at site wrought middle steel galvanized GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for BWSSB & KUWS common SR 2023-24 Vol-5 item no 11.7.3, page no.129 Heavy Duty GI pipe of 25mm dia Elbow | No | 127.05 | 127.05 | 48.0 | False | None | None | False | None | False | 6098.4 | 0 | 2927060 | 96500 | None | code31 | Supply and delivery at site wrought middle steel galvanized GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for BWSSB & KUWS common SR 2023-24 Vol-5 item no 11.7.3, page no.129 Heavy Duty GI pipe of 20mm dia Elbow | No | 103.95 | 103.95 | 200.0 | False | None | None | False | None | False | 20790.0 | 0 | 2927061 | 96500 | None | code32 | Supply and delivery at site wrought middle steel galvanized GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for BWSSB & KUWS common SR 2023-24 Vol-5 item no 11.7.3, page no.129 Heavy Duty GI pipe of 40mm dia Elbow | No | 216.3 | 216.3 | 80.0 | False | None | None | False | None | False | 17304.0 | 0 |
|