tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1709620942000 | 0 | None | None | Buildings | CONSTRUCTION OF DISTRICT INTEGRATED PUBLIC HEALTH LABORATORY IN THE PREMISES OF DISTRICT HOSPITAL AT MYSURU. (Civil Works) | 9099866.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2917255 | 95987 | None | I-2.5A P-7 V-3 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer.A In area of light jungle ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | 100 Sqm | 486.93 | 486.93 | 3.85 | False | None | None | False | None | False | 1874.6805 | 0 | 2917256 | 95987 | None | I-1.12 P-8 V-1 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 117.71 | 117.71 | 115.5 | False | None | None | False | None | False | 13595.505 | 0 | 2917257 | 95987 | None | I-1.14.1 P-8 V-1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 126.38 | 126.38 | 122.85 | False | None | None | False | None | False | 15525.783 | 0 | 2917258 | 95987 | None | I-1.15.1 P-8 V-1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 449.76 | 449.76 | 13.16 | False | None | None | False | None | False | 5918.8416 | 0 | 2917259 | 95987 | None | I-1.1A P-3 V-3 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Tipper 5.5 m3) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 167.27 | 167.27 | 63.16 | False | None | None | False | None | False | 10564.7732 | 0 | 2917260 | 95987 | None | I-4.1 P-5 V-2 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 146.2 | 146.2 | 305.5 | False | None | None | False | None | False | 44664.1 | 0 | 2917261 | 95987 | None | I-1.9 P-7 V-1 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 329.57 | 329.57 | 123.34 | False | None | None | False | None | False | 40649.1638 | 0 | 2917262 | 95987 | None | I-1.8 P-7 V-1 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 587.29 | 587.29 | 374.11 | False | None | None | False | None | False | 219711.0619 | 0 | 2917263 | 95987 | None | I-2.1.3 P-15 V-1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 7420.37 | 7420.37 | 47.18 | False | None | None | False | None | False | 350093.0566 | 0 | 2917264 | 95987 | None | I-2.2.1 P-15 V-1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FOOTINGS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 8412.76 | 8412.76 | 26.51 | False | None | None | False | None | False | 223022.2676 | 0 | 2917265 | 95987 | None | I-2.2.1 P-15 V-1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PEDESTALS ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 8568.55 | 8568.55 | 3.38 | False | None | None | False | None | False | 28961.699 | 0 | 2917266 | 95987 | None | I-2.5.2 P-17 V-1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates COLUMNS GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 14413.41 | 14413.41 | 16.5 | False | None | None | False | None | False | 237821.265 | 0 | 2917267 | 95987 | None | I-2.5.2 P-17 V-1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM, RCC SLAB GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 12717.72 | 12717.72 | 74.4 | False | None | None | False | None | False | 946198.368 | 0 | 2917268 | 95987 | None | I-2.5.2 P-17 V-1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC BEAMS, LINTELS GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 13565.56 | 13565.56 | 20.07 | False | None | None | False | None | False | 272260.7892 | 0 | 2917269 | 95987 | None | I-2.1.4 P-15 V-1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 8473.15 | 8473.15 | 5.04 | False | None | None | False | None | False | 42704.676 | 0 | 2917270 | 95987 | None | I-15.4 P-117 V-3 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cutting/removal and sealing of the hole as necessary of nipples after completion of grouting with Cement/Epoxy GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 252.76 | 252.76 | 20.0 | False | None | None | False | None | False | 5055.2 | 0 | 2917271 | 95987 | None | I-8.16A P-55 V-2 | Providing Lath plaster with cement mortar 1:3 5cm thick with 6mm dia mild steel bars at 20cms. C to c both horizontally and vertically fixing chicken mesh for drop chejjas, facia, backing to cup board including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specification. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1533.88 | 1533.88 | 4.73 | False | None | None | False | None | False | 7255.2524 | 0 | 2917272 | 95987 | None | I-2.11a P-84 V-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, b ending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Tonne | 110837.22 | 110837.22 | 16.39 | False | None | None | False | None | False | 1816622.0358 | 0 | 2917273 | 95987 | None | I-5.4 P-9 V-2 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 7915.97 | 7915.97 | 5.87 | False | None | None | False | None | False | 46466.7439 | 0 | 2917274 | 95987 | None | I-6.32 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1623.09 | 1623.09 | 492.27 | False | None | None | False | None | False | 798998.5143 | 0 | 2917275 | 95987 | None | I-6.34 P-17 V-2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1367.86 | 1367.86 | 56.4 | False | None | None | False | None | False | 77147.304 | 0 | 2917276 | 95987 | None | I-12.13.1 P-100 V-2 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 122431.79 | 122431.79 | 1.58 | False | None | None | False | None | False | 193442.2282 | 0 | 2917277 | 95987 | None | I-12.51 P-105 V-2 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 1258.82 | 1258.82 | 16.0 | False | None | None | False | None | False | 20141.12 | 0 | 2917278 | 95987 | None | I-10.6.3 P-69 V-2 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 74.34 | 74.34 | 96.0 | False | None | None | False | None | False | 7136.64 | 0 | 2917279 | 95987 | None | I-12.57.6 P-106 V-2 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 4115.96 | 4115.96 | 48.0 | False | None | None | False | None | False | 197566.08 | 0 | 2917280 | 95987 | None | I-12.90 P-112 V-2 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 8343.43 | 8343.43 | 33.75 | False | None | None | False | None | False | 281590.7625 | 0 | 2917281 | 95987 | None | I-12.85 P-110 V-2 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 7085.84 | 7085.84 | 3.78 | False | None | None | False | None | False | 26784.4752 | 0 | 2917282 | 95987 | None | I-11.34A P-110 V-2 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Kg | 208.15 | 208.15 | 788.13 | False | None | None | False | None | False | 164049.2595 | 0 | 2917283 | 95987 | None | I-12.93.1 P-112 V-2 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). Size 62 x 100mm. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 869.78 | 869.78 | 20.4 | False | None | None | False | None | False | 17743.512 | 0 | 2917284 | 95987 | None | I-12.94.2 P-112 V-2 | Providing and fixing factory made Green certified, Anti Termite, UV resistant,high water absorbant si ngle extruded WPC (Wood PolymerComposite) solidplain flush door shutter of required size comprising of virgin polymer ofK value 58-60 (Suspension Grade), calcium carbonate and natural fibers
(wood powder/rice husk/wheat husk) and non toxic additives (maximumtoxicity index of 12 for 100 g) having minimum density of 650 kg/m3 andscrew withdrawal strength of 1800 N (Face) & 900 N (Edge), minimumcompressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 andresistance to spread of flame of Class A category with property of being
termite/borer proof, water/moisture proof and fire retardant and fixingwith stainless steel butt hinges of required size with necessary full bodythreaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to bepaid separately) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 5006.8 | 5006.8 | 7.56 | False | None | None | False | None | False | 37851.408 | 0 | 2917285 | 95987 | None | I-12.59 P-107 V-2 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 1380.25 | 1380.25 | 16.0 | False | None | None | False | None | False | 22084.0 | 0 | 2917286 | 95987 | None | I-11.25.2 P-109 V-2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Kgs | 168.5 | 168.5 | 241.92 | False | None | None | False | None | False | 40763.52 | 0 | 2917287 | 95987 | None | I-8.4.2 P-41 V-2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 386.57 | 386.57 | 768.67 | False | None | None | False | None | False | 297144.7619 | 0 | 2917288 | 95987 | None | I-8.10 P-42 V-2 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 261.43 | 261.43 | 529.04 | False | None | None | False | None | False | 138306.9272 | 0 | 2917289 | 95987 | None | I-8.51 P-50 V-2 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Gf ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 123.9 | 123.9 | 1297.71 | False | None | None | False | None | False | 160786.269 | 0 | 2917290 | 95987 | None | I-8.5.2 P-42 V-2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 432.41 | 432.41 | 322.67 | False | None | None | False | None | False | 139525.7347 | 0 | 2917291 | 95987 | None | I-8.16.2 P-43 V-2 | Providing and fixing suitable plaster mesh 150 mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment. Plaster mesh 150mm wide GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Rmtr | 44.84 | 44.84 | 972.0 | False | None | None | False | None | False | 43584.48 | 0 | 2917292 | 95987 | None | I-8.79 P-54 V-2 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Rmtr | 64.43 | 64.43 | 292.0 | False | None | None | False | None | False | 18813.56 | 0 | 2917293 | 95987 | None | I-9.17.2 P-61 V-2 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete..).Size of Tile 600x600 mm GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1455.83 | 1455.83 | 265.08 | False | None | None | False | None | False | 385911.4164 | 0 | 2917294 | 95987 | None | I-8.2.1 P-41 V-2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 365.51 | 365.51 | 133.88 | False | None | None | False | None | False | 48934.4788 | 0 | 2917295 | 95987 | None | I-9.24 P-63 V-2 | Providing and laying Polished Granite flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 3533.63 | 3533.63 | 37.28 | False | None | None | False | None | False | 131733.7264 | 0 | 2917296 | 95987 | None | I-9.29 P-64 V-2 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 5335.13 | 5335.13 | 31.44 | False | None | None | False | None | False | 167736.4872 | 0 | 2917297 | 95987 | None | I-15.7 P-134 V-2 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 761.99 | 761.99 | 25.62 | False | None | None | False | None | False | 19522.1838 | 0 | 2917298 | 95987 | None | I-9.11 P-60 V-2 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1101.47 | 1101.47 | 25.62 | False | None | None | False | None | False | 28219.6614 | 0 | 2917299 | 95987 | None | I-9.39 P-65 V-2 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1795.31 | 1795.31 | 96.6 | False | None | None | False | None | False | 173426.946 | 0 | 2917300 | 95987 | None | I-8.39 P-48 V-2 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 157.35 | 157.35 | 529.04 | False | None | None | False | None | False | 83244.444 | 0 | 2917301 | 95987 | None | I-8.32 P-45 V-2 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 193.28 | 193.28 | 322.67 | False | None | None | False | None | False | 62365.6576 | 0 | 2917302 | 95987 | None | I-8.34.3 P-47 V-2 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 61.95 | 61.95 | 37.53 | False | None | None | False | None | False | 2324.9835 | 0 | 2917303 | 95987 | None | I-8.40 P-48 V-2 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 142.49 | 142.49 | 37.53 | False | None | None | False | None | False | 5347.6497 | 0 | 2917304 | 95987 | None | I-8.34.1 P-47 V-2 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 65.67 | 65.67 | 115.2 | False | None | None | False | None | False | 7565.184 | 0 | 2917305 | 95987 | None | I-8.47 P-49 V-2 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture : New work to give an even surface including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 167.27 | 167.27 | 115.2 | False | None | None | False | None | False | 19269.504 | 0 | 2917306 | 95987 | None | I-12.92 P-112 V-2 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 7737.56 | 7737.56 | 8.4 | False | None | None | False | None | False | 64995.504 | 0 | 2917307 | 95987 | None | I-12.91 P-112 V-2 | Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 7510.82 | 7510.82 | 29.79 | False | None | None | False | None | False | 223747.3278 | 0 | 2917308 | 95987 | None | I-10.2 S.R 2018-19 | KSRB 10-3 :Providing and laying integral cement based waterproofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc , consisting of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75 kglsqm of cement admixed with proprietary water proofing compound conforming to 18:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 1OOmm size with 50% of cement mortar 1:5 admixed with proprietary water proofing compound conforming 18:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement lurry admixed with proprietary water proofing compound (d) Finishing the surface with 20mm thick joint less cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 1226.34 | 1226.34 | 328.86 | False | None | None | False | None | False | 403294.1724 | 0 | 2917309 | 95987 | None | I-10.1.7 P-134 V-5 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Rmtr | 514.32 | 514.32 | 24.0 | False | None | None | False | None | False | 12343.68 | 0 | 2917310 | 95987 | None | I-10.1.2 P-62 V-2 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut forkitchen platforms, vanity counters, window sills, facias and similar locationsof required size, approved shade, colour and texture laid over 20 mm
thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treatedwith white cement, mixed with matching pigment, epoxy touch up,including rubbing, curing, moulding and polishing to edges to give highgloss finish etc. complete at all levels. GF ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sqm | 4877.94 | 4877.94 | 50.73 | False | None | None | False | None | False | 247457.8962 | 0 |
| 1709620942000 | 0 | None | None | Buildings | CONSTRUCTION OF DISTRICT INTEGRATED PUBLIC HEALTH LABORATORY IN THE PREMISES OF DISTRICT HOSPITAL AT MYSURU. (Water and Sanitary Works) | 316773.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2917311 | 95988 | None | I-16.7.4 P-187 V-5 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 172.22 | 172.22 | 15.0 | False | None | None | False | None | False | 2583.3 | 0 | 2917312 | 95988 | None | I-10.1.5 P-34 V-5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinationsand cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approvedtype, with all labour with all lead & lift including encasing the pipealround to a depth of not less than 15 cms. with soft gravel or selectedearth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will makehis own arrangements for procuring water for testing) etc. complete ForPVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 272.58 | 272.58 | 40.0 | False | None | None | False | None | False | 10903.2 | 0 | 2917313 | 95988 | None | I-10.1.7 P-34 V-5 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latestamendments and conveying to worksite, rolling and lowering intotrenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinationsand cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approvedtype, with all labour with all lead & lift including encasing the pipealround to a depth of not less than 15 cms. with soft gravel or selectedearth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will makehis own arrangements for procuring water for testing) etc. complete ForPVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 509.23 | 509.23 | 30.0 | False | None | None | False | None | False | 15276.9 | 0 | 2917314 | 95988 | None | I-13.47 V-2 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 244.08 | 244.08 | 30.0 | False | None | None | False | None | False | 7322.4 | 0 | 2917315 | 95988 | None | I-13.48 V-2 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 360.55 | 360.55 | 20.0 | False | None | None | False | None | False | 7211.0 | 0 | 2917316 | 95988 | None | I-14.31 P-128 V-2 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 1511.58 | 1511.58 | 4.0 | False | None | None | False | None | False | 6046.32 | 0 | 2917317 | 95988 | None | I-13.16 P-117 V-2 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 768.18 | 768.18 | 10.0 | False | None | None | False | None | False | 7681.8 | 0 | 2917318 | 95988 | None | I-14.3.2 P-123 V-2 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 7192.4 | 7192.4 | 4.0 | False | None | None | False | None | False | 28769.6 | 0 | 2917319 | 95988 | None | I-14.28.2.2 P-128 V-2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 113.99 | 113.99 | 10.0 | False | None | None | False | None | False | 1139.9 | 0 | 2917320 | 95988 | None | I-13.15 P-117 V-2 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 898.28 | 898.28 | 10.0 | False | None | None | False | None | False | 8982.8 | 0 | 2917321 | 95988 | None | I-14.11.2 P-126 V-2 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 6296.6 | 6296.6 | 4.0 | False | None | None | False | None | False | 25186.4 | 0 | 2917322 | 95988 | None | I-14.7.1 P-124 V-2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 3818.6 | 3818.6 | 2.0 | False | None | None | False | None | False | 7637.2 | 0 | 2917323 | 95988 | None | I-14.22A P-127 V-2 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 1003.59 | 1003.59 | 6.0 | False | None | None | False | None | False | 6021.54 | 0 | 2917324 | 95988 | None | I-14.37.1 P-129 V-2 | Providing and fixing Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than
260 gms ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 379.13 | 379.13 | 6.0 | False | None | None | False | None | False | 2274.78 | 0 | 2917325 | 95988 | None | 13.28.1 | Providing and fixing P.T.M.T. extension nipple 15mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 79.3 | 79.3 | 20.0 | False | None | None | False | None | False | 1586.0 | 0 | 2917326 | 95988 | None | I-13.2.1 P-115 V-2 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 354.35 | 354.35 | 10.0 | False | None | None | False | None | False | 3543.5 | 0 | 2917327 | 95988 | None | I-13.32.1 P-120 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 382.85 | 382.85 | 20.0 | False | None | None | False | None | False | 7657.0 | 0 | 2917328 | 95988 | None | I-13.32.2 P-120 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 469.58 | 469.58 | 30.0 | False | None | None | False | None | False | 14087.4 | 0 | 2917329 | 95988 | None | I-13.33.2 P-120 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 20 mm nominal dia Pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 268.86 | 268.86 | 30.0 | False | None | None | False | None | False | 8065.8 | 0 | 2917330 | 95988 | None | I-13.33.3 P-120 V-2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) External & Shafts & Terrace 25 mm nominal dia Pipes ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 366.74 | 366.74 | 20.0 | False | None | None | False | None | False | 7334.8 | 0 | 2917331 | 95988 | None | I-13.4.1 P-115 V-2 | Providing and fixing Brass full way valve with C.I. wheel (screwed end) 25 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 680.21 | 680.21 | 8.0 | False | None | None | False | None | False | 5441.68 | 0 | 2917332 | 95988 | None | I-16.9 P-187 V-5 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 6757.51 | 6757.51 | 5.0 | False | None | None | False | None | False | 33787.55 | 0 | 2917333 | 95988 | None | I-13.34 P-120 V-2 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | l | 11.15 | 11.15 | 2000.0 | False | None | None | False | None | False | 22300.0 | 0 | 2917334 | 95988 | None | Approved rate | Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS Standards 10Cms X 7.5Cms ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 371.7 | 371.7 | 10.0 | False | None | None | False | None | False | 3717.0 | 0 | 2917335 | 95988 | None | Approved rate | Air Vent Cowel 75mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 413.0 | 413.0 | 10.0 | False | None | None | False | None | False | 4130.0 | 0 | 2917336 | 95988 | None | Approved rate | Air Vent Cowel 110mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 590.0 | 590.0 | 5.0 | False | None | None | False | None | False | 2950.0 | 0 | 2917337 | 95988 | None | Approved rate | Providing and fixing testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 1180.0 | 1180.0 | 4.0 | False | None | None | False | None | False | 4720.0 | 0 | 2917338 | 95988 | None | Approved rate | Providing and fixing, testing and commissioning approved make submersible pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,Duty of Pump : 6.0cum/hr @ 35.0m Head (1 No. Working + 1 No. Stand By) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 23600.0 | 23600.0 | 2.0 | False | None | None | False | None | False | 47200.0 | 0 | 2917339 | 95988 | None | Approved rate | Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).15cms x 10cms ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 3304.0 | 3304.0 | 4.0 | False | None | None | False | None | False | 13216.0 | 0 |
| 1709620942000 | 0 | None | None | Buildings | CONSTRUCTION OF DISTRICT INTEGRATED PUBLIC HEALTH LABORATORY IN THE PREMISES OF DISTRICT HOSPITAL at MYSURU. (Electrical Works) | 1025422.23 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2917340 | 95989 | None | 2.1.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete
for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Point | 353.12 | 353.12 | 25.0 | False | None | None | False | None | False | 8828.0 | 0 | 2917341 | 95989 | None | 2.1.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete
for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Point | 488.17 | 488.17 | 34.0 | False | None | None | False | None | False | 16597.78 | 0 | 2917342 | 95989 | None | 2.1.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete
for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Point | 706.23 | 706.23 | 60.0 | False | None | None | False | None | False | 42373.8 | 0 | 2917343 | 95989 | None | 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 170.98 | 170.98 | 20.0 | False | None | None | False | None | False | 3419.6 | 0 | 2917344 | 95989 | None | 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 219.3 | 219.3 | 8.0 | False | None | None | False | None | False | 1754.4 | 0 | 2917345 | 95989 | None | 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 272.58 | 272.58 | 4.0 | False | None | None | False | None | False | 1090.32 | 0 | 2917346 | 95989 | None | 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 323.38 | 323.38 | 10.0 | False | None | None | False | None | False | 3233.8 | 0 | 2917347 | 95989 | None | 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 395.24 | 395.24 | 35.0 | False | None | None | False | None | False | 13833.4 | 0 | 2917348 | 95989 | None | 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-2module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 169.74 | 169.74 | 20.0 | False | None | None | False | None | False | 3394.8 | 0 | 2917349 | 95989 | None | 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4-5 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 216.83 | 216.83 | 8.0 | False | None | None | False | None | False | 1734.64 | 0 | 2917350 | 95989 | None | 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 289.93 | 289.93 | 4.0 | False | None | None | False | None | False | 1159.72 | 0 | 2917351 | 95989 | None | 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 351.88 | 351.88 | 10.0 | False | None | None | False | None | False | 3518.8 | 0 | 2917352 | 95989 | None | 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 426.22 | 426.22 | 35.0 | False | None | None | False | None | False | 14917.7 | 0 | 2917353 | 95989 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 126.38 | 126.38 | 45.0 | False | None | None | False | None | False | 5687.1 | 0 | 2917354 | 95989 | None | 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 205.67 | 205.67 | 184.0 | False | None | None | False | None | False | 37843.28 | 0 | 2917355 | 95989 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 211.87 | 211.87 | 79.0 | False | None | None | False | None | False | 16737.73 | 0 | 2917356 | 95989 | None | 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Bell push ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 219.3 | 219.3 | 5.0 | False | None | None | False | None | False | 1096.5 | 0 | 2917357 | 95989 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 442.32 | 442.32 | 24.0 | False | None | None | False | None | False | 10615.68 | 0 | 2917358 | 95989 | None | 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 223.02 | 223.02 | 15.0 | False | None | None | False | None | False | 3345.3 | 0 | 2917359 | 95989 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 403.91 | 403.91 | 21.0 | False | None | None | False | None | False | 8482.11 | 0 | 2917360 | 95989 | None | 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 292.4 | 292.4 | 18.0 | False | None | None | False | None | False | 5263.2 | 0 | 2917361 | 95989 | None | 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 193.28 | 193.28 | 2.0 | False | None | None | False | None | False | 386.56 | 0 | 2917362 | 95989 | None | 1.9.2 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface
over inverted tapered wooden plugs or phill plugs or rawl plugs and
clamped using heavy gauge saddles at an interval of 300 mm using NF
screws and on either end of the pipe terminated completely 25 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 27.26 | 27.26 | 50.0 | False | None | None | False | None | False | 1363.0 | 0 | 2917363 | 95989 | None | 1.2.1 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 81.77 | 81.77 | 800.0 | False | None | None | False | None | False | 65416.0 | 0 | 2917364 | 95989 | None | 1.2.2 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 96.64 | 96.64 | 500.0 | False | None | None | False | None | False | 48320.0 | 0 | 2917365 | 95989 | None | 1.3.1 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 84.25 | 84.25 | 400.0 | False | None | None | False | None | False | 33700.0 | 0 | 2917366 | 95989 | None | 1.3.2 | Groove Cutting in Wall Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 97.88 | 97.88 | 250.0 | False | None | None | False | None | False | 24470.0 | 0 | 2917367 | 95989 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 32.21 | 32.21 | 400.0 | False | None | None | False | None | False | 12884.0 | 0 | 2917368 | 95989 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 52.04 | 52.04 | 800.0 | False | None | None | False | None | False | 41632.0 | 0 | 2917369 | 95989 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 78.06 | 78.06 | 500.0 | False | None | None | False | None | False | 39030.0 | 0 | 2917370 | 95989 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 Sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 113.99 | 113.99 | 300.0 | False | None | None | False | None | False | 34197.0 | 0 | 2917371 | 95989 | None | 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure II- Double Door 12 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 2885.63 | 2885.63 | 2.0 | False | None | None | False | None | False | 5771.26 | 0 | 2917372 | 95989 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A DP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 915.62 | 915.62 | 40.0 | False | None | None | False | None | False | 36624.8 | 0 | 2917373 | 95989 | None | 5.20.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB)
240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 5299.2 | 5299.2 | 2.0 | False | None | None | False | None | False | 10598.4 | 0 | 2917374 | 95989 | None | I-32.03 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 10 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Km | 146206.96 | 146206.96 | 0.1 | False | None | None | False | None | False | 14620.696 | 0 | 2917375 | 95989 | None | I-21.05 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. 6 sqmm to 16 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Km | 25877.75 | 25877.75 | 0.1 | False | None | None | False | None | False | 2587.775 | 0 | 2917376 | 95989 | None | 1.6.1 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal ofstumps and other deleterious matter, including dressing of excavatedsurfaces, disposing off or leveling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m. Filling
available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidatingeach deposited layer by ramming and watering and lift upto 1.5 mincluding cost of labour, tools, usage& other appurtenances requiredto complete the work. In all kinds of soils. Depth upto 1.50m ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Cum | 675.26 | 675.26 | 50.0 | False | None | None | False | None | False | 33763.0 | 0 | 2917377 | 95989 | None | 13.2.3 | Supplying and Fixing........mm dia clampsss A GI pipe bracket upto
2.7 meters long terminated with a reducing collar of 40x25mm to
which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL
street light fitting of all capacities on rail/RCC/wall/tubular pole,
using suitable clamps, bolts, nuts and wiring using suitable capacity
wires. Using 40mm dia G.I.Pipe ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 1831.24 | 1831.24 | 5.0 | False | None | None | False | None | False | 9156.2 | 0 | 2917378 | 95989 | None | I-12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.
cutouts and other equipment's on the meter board using 40 mm dia
2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the
pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification
7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | No | 4348.89 | 4348.89 | 2.0 | False | None | None | False | None | False | 8697.78 | 0 | 2917379 | 95989 | None | 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 101.6 | 101.6 | 30.0 | False | None | None | False | None | False | 3048.0 | 0 | 2917380 | 95989 | None | 12.58.5 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 50 x 6 mm GI strip ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 270.1 | 270.1 | 15.0 | False | None | None | False | None | False | 4051.5 | 0 | 2917381 | 95989 | None | 11.3.2 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 854.91 | 854.91 | 53.0 | False | None | None | False | None | False | 45310.23 | 0 | 2917382 | 95989 | None | 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 1096.52 | 1096.52 | 10.0 | False | None | None | False | None | False | 10965.2 | 0 | 2917383 | 95989 | None | 11.11.3 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 184.61 | 184.61 | 6.0 | False | None | None | False | None | False | 1107.66 | 0 | 2917384 | 95989 | None | 11.11.5 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per watt, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12W, 6500K ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 333.29 | 333.29 | 10.0 | False | None | None | False | None | False | 3332.9 | 0 | 2917385 | 95989 | None | 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than130lm/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | No | 4985.74 | 4985.74 | 2.0 | False | None | None | False | None | False | 9971.48 | 0 | 2917386 | 95989 | None | 6.2.1 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades
suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300 mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 3678.59 | 3678.59 | 10.0 | False | None | None | False | None | False | 36785.9 | 0 | 2917387 | 95989 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod
blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 3697.18 | 3697.18 | 24.0 | False | None | None | False | None | False | 88732.32 | 0 | 2917388 | 95989 | None | 6.5.2 | Supplying wall mounting fan suitable to operate at single phase 230v AC. Supply 400 mm Sweep ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 3979.67 | 3979.67 | 4.0 | False | None | None | False | None | False | 15918.68 | 0 | 2917389 | 95989 | None | I-12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 78.06 | 78.06 | 16.0 | False | None | None | False | None | False | 1248.96 | 0 | 2917390 | 95989 | None | 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 151.16 | 151.16 | 53.0 | False | None | None | False | None | False | 8011.48 | 0 | 2917391 | 95989 | None | I-13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 390.29 | 390.29 | 28.0 | False | None | None | False | None | False | 10928.12 | 0 | 2917392 | 95989 | None | I-13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 875.97 | 875.97 | 10.0 | False | None | None | False | None | False | 8759.7 | 0 | 2917393 | 95989 | None | I-13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 200.72 | 200.72 | 2.0 | False | None | None | False | None | False | 401.44 | 0 | 2917394 | 95989 | None | 7.2.1 | Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate .2KW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.5 Star With Fibre body 25Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 14780.03 | 14780.03 | 1.0 | False | None | None | False | None | False | 14780.03 | 0 | 2917395 | 95989 | None | 13.15.1 | Erection charges for fixing a ... litres capacity wall mounting
electric geysers using bolts, flat at one end nut and washers at
the other end for through bolts and nuts and washers with
150x450x600mm back plate and wiring complete with 15A 3
pin top upto 30 Litres ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 822.7 | 822.7 | 1.0 | False | None | None | False | None | False | 822.7 | 0 | 2917396 | 95989 | None | 5.42.1 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Sq CM | 0.62 | 0.62 | 15000.0 | False | None | None | False | None | False | 9300.0 | 0 | 2917397 | 95989 | None | 5.40.1 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 3054.14 | 3054.14 | 2.0 | False | None | None | False | None | False | 6108.28 | 0 | 2917398 | 95989 | None | 5.40.3 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 5507.36 | 5507.36 | 3.0 | False | None | None | False | None | False | 16522.08 | 0 | 2917399 | 95989 | None | 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 377.9 | 377.9 | 4.0 | False | None | None | False | None | False | 1511.6 | 0 | 2917400 | 95989 | None | 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | m | 936.68 | 936.68 | 5.0 | False | None | None | False | None | False | 4683.4 | 0 | 2917401 | 95989 | None | 5.44.3 | Supply and Installation / Fixing / Provision of Outdoor type
Thermoplastic Modular Panel enclosure with transparent
Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust
proof, dust proof, water proof, corrosion proof having internally
Embedded gasket on both lid and flap suitable to fix Single
Phase / Three Phase Energy Meter in suitable base plate and
having a provision for Fuse / MCB cut-out with suitable
transparent hinged flap opening for operating MCB along with
complete tamper proof SEALING facility. 300 mm x 600 mm x 170 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Nos | 8508.21 | 8508.21 | 1.0 | False | None | None | False | None | False | 8508.21 | 0 | 2917402 | 95989 | None | 5.15.1 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) THREE POLE 100 A 25 kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 7540.55 | 7540.55 | 1.0 | False | None | None | False | None | False | 7540.55 | 0 | 2917403 | 95989 | None | 5.15.2 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) THREE POLE 125 A 25 kA ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 10652.92 | 10652.92 | 1.0 | False | None | None | False | None | False | 10652.92 | 0 | 2917404 | 95989 | None | 5.19.8 | Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG
MS enclosure. II - Double Door 8 Way SP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 2297.11 | 2297.11 | 1.0 | False | None | None | False | None | False | 2297.11 | 0 | 2917405 | 95989 | None | 5.19.14 | Supplying and fixing regular MCB distribution boards on wall/ood
board / flush mounting using required clamps, bolts, nuts etc., with
provision for fixing suitable type capacity MCB's single phase/3
phase/single door with powder coated painting Made out of 14 SWG
MS enclosure. II - Double Door 12 Way TP & N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 10822.67 | 10822.67 | 1.0 | False | None | None | False | None | False | 10822.67 | 0 | 2917406 | 95989 | None | 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 514.19 | 514.19 | 15.0 | False | None | None | False | None | False | 7712.85 | 0 | 2917407 | 95989 | None | 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 3771.52 | 3771.52 | 2.0 | False | None | None | False | None | False | 7543.04 | 0 | 2917408 | 95989 | None | 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 3826.03 | 3826.03 | 1.0 | False | None | None | False | None | False | 3826.03 | 0 | 2917409 | 95989 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 298.6 | 298.6 | 1.0 | False | None | None | False | None | False | 298.6 | 0 | 2917410 | 95989 | None | 5.7.3 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 63Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 496.84 | 496.84 | 1.0 | False | None | None | False | None | False | 496.84 | 0 | 2917411 | 95989 | None | 5.12.1 | Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 63Amps ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 8525.56 | 8525.56 | 1.0 | False | None | None | False | None | False | 8525.56 | 0 | 2917412 | 95989 | None | I-5.23 | Supplying, fixing and wiring 0 to 30V Direct Reading DC
Voltmeter/Ammeter. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 854.91 | 854.91 | 1.0 | False | None | None | False | None | False | 854.91 | 0 | 2917413 | 95989 | None | I-5.25 | Supplying, fixing and wiring 0 to 100 A Direct Reading AC analog
type Ammeter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 649.24 | 649.24 | 1.0 | False | None | None | False | None | False | 649.24 | 0 | 2917414 | 95989 | None | I-5.26 | Supplying, fixing and wiring 0 to 1500A CT operated AC analog type
Ammeter without CT ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 594.72 | 594.72 | 1.0 | False | None | None | False | None | False | 594.72 | 0 | 2917415 | 95989 | None | I-5.33 | Supplying of multi function digital meter with three line back light
LCD type display for voltage, Current, frequency, Power, power
factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network
with IP 54 degree of protection and completely wired as required with
communication Port and Class 0.5s accuracy ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 11541.29 | 11541.29 | 1.0 | False | None | None | False | None | False | 11541.29 | 0 | 2917416 | 95989 | None | I-5.27 | Supplying, fixing and wiring rotary selector switch suitable for Ammeter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 247.8 | 247.8 | 1.0 | False | None | None | False | None | False | 247.8 | 0 | 2917417 | 95989 | None | I-5.28 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 2917418 | 95989 | None | I-5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 1765.58 | 1765.58 | 2.0 | False | None | None | False | None | False | 3531.16 | 0 | 2917419 | 95989 | None | I-5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C (48/6.36) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 638.09 | 638.09 | 3.0 | False | None | None | False | None | False | 1914.27 | 0 | 2917420 | 95989 | None | I-5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound (48/6.32) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 696.32 | 696.32 | 3.0 | False | None | None | False | None | False | 2088.96 | 0 | 2917421 | 95989 | None | I-5.30 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to
20A single phase Class-1 Accuracy with Temper Proof Energy
Meter. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Each | 1709.82 | 1709.82 | 3.0 | False | None | None | False | None | False | 5129.46 | 0 |
| 1709620942000 | 0 | None | None | Buildings | CONSTRUCTION OF DISTRICT INTEGRATED PUBLIC HEALTH LABORATORY IN THE PREMISES OF DISTRICT HOSPITAL at MYSURU. (Consultancy Charges) | 78300.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2917422 | 95990 | None | 1.0.0 | Preparation of detailed Architectural drawings,Structural design and drawings including Soil exploration as per I.S Codes and proof checking by IISC/NIT/IIT only as decided by the Department and the same has to be furnished to the Department for approval and also providing consultancy for Architectural & structural designs & Drawings and Elevations floor wise, preparation of internal and external Electrical works schematic drawings and working drawings for public health engineering drawings, interior layout etc and liaison with other department and approval of pollution control board & any other statutory approval from the concerned dept and drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - etc., complete including all lead and lift and work to be executed as per the specification and engineer -in-charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | LS | 78300.0 | 78300.0 | 1.0 | False | None | None | False | None | False | 78300.0 | 0 |
|
|
---|