createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709704801176
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1415000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-03-2024 16:00:00
tenderQueryClose12-03-2024 14:30:00
technicalBidOpen21-03-2024 16:00:01
publishedDate06-03-2024 13:33:15
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate13-03-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTechnical Assistant
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843249
tenderSupplierListNone
tenderSchedule
createdTs1709704801334
version12
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT109
titleConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.
descriptionConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.
categoryWORKS
categoryTextWorks
ecv94319465.95
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount99800000.0
groupOverheadTotal0.0
fileNumberAEE/BGM/2023-24/BIMS/Burnsward
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17097048010000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(Civil work)49096937.48
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293191296729NoneV-3 Pg No 9 Itm No 2.5(ii)aClearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc.,complete with all leadSqm486.92486.929.99FalseNoneNoneFalseNoneFalse4864.33080
293191396729NoneV-1 Pg No 8 Itm No 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. in all kinds of soils up to 300mm depth ---- etc.,complete with all leadCum117.7117.7903.34FalseNoneNoneFalseNoneFalse106323.1180
293191496729NoneV-1 Pg No 8 Itm No 1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc.,complete with all leadCum126.37126.371440.42FalseNoneNoneFalseNoneFalse182025.87540
293191596729NoneV-1 Pg No 8 Itm No 1.15.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc.,complete with all leadCum449.75449.75171.05FalseNoneNoneFalseNoneFalse76929.73750
293191696729NoneV-1 Pg No 8 Itm No 1.15.2Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc.,complete with all leadCum526.57526.5754.87FalseNoneNoneFalseNoneFalse28892.89590
293191796729NoneV-3 Pg No 3 Itm No 1.1ALoading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. ---- etc.,complete with all leadCum167.26167.26425.92FalseNoneNoneFalseNoneFalse71239.37920
293191896729NoneV-2 Pg No 5 Itm No 4.1Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc.,complete with all leadSqm146.2146.2740.52FalseNoneNoneFalseNoneFalse108264.0240
293191996729NoneV-1 Pg No 7 Itm No 1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc.,complete with all leadCum329.57329.571011.69FalseNoneNoneFalseNoneFalse333422.67330
293192096729NoneV-1 Pg No 7 Itm No 1.8Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc.,complete with all leadCum587.28587.28243.69FalseNoneNoneFalseNoneFalse143114.26320
293192196729NoneV-1 Pg No 15 Itm No 2.1.3Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc.,complete with all leadCum7420.377420.37155.88FalseNoneNoneFalseNoneFalse1156687.27560
293192296729NoneV-1 Pg No 15 Itm No 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. FOOTINGS ---- etc.,complete with all leadCum8478.328478.32328.01FalseNoneNoneFalseNoneFalse2780973.74320
293192396729NoneV-1 Pg No 15 Itm No 2.2.3Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. PEDESTALS ---- etc.,complete with all leadCum8635.338635.337.21FalseNoneNoneFalseNoneFalse62260.72930
293192496729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS LIFT CORE WALL pump room and sump tank-walls-GROUND FLOOR ---- etc.,complete with all leadCum14413.4114413.4188.07FalseNoneNoneFalseNoneFalse1269389.01870
293192596729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. PLINTH BEAM RCC SLAB Cover slab-GROUND FLOOR ---- etc.,complete with all leadCum12717.7112717.71192.45FalseNoneNoneFalseNoneFalse2447523.28950
293192696729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS and LINTELS-GROUND FLOOR ---- etc.,complete with all leadCum13565.5613565.5668.28FalseNoneNoneFalseNoneFalse926256.43680
293192796729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC STAIRCASE-GROUND FLOOR ---- etc.,complete with all leadCum12293.7912293.7910.77FalseNoneNoneFalseNoneFalse132404.11830
293192896729NoneV-1 Pg No 16 Itm No 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. GROUND FLOOR ---- etc.,complete with all leadCum9036.029036.023.66FalseNoneNoneFalseNoneFalse33071.83320
293192996729NoneV-2 Pg No 43 Itm No 8.16 aProviding lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadSqm1533.881533.885.7FalseNoneNoneFalseNoneFalse8743.1160
293193096729NoneV-1 Pg No 18 Itm No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GROUND FLOOR ---- etc.,complete with all leadt110837.22110837.2265.42FalseNoneNoneFalseNoneFalse7250970.93240
293193196729None18-19 SR Pg No 15 Itm No 4.21Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. GROUND FLOOR ---- etc.,complete with all leadm38.9438.94226.8FalseNoneNoneFalseNoneFalse8831.5920
293193296729None021Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc.,complete with all leadm86.1486.14352.4FalseNoneNoneFalseNoneFalse30355.7360
293193396729NoneV-2 Pg No 9 Itm No 5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc.,complete with all leadCum7915.977915.9715.0FalseNoneNoneFalseNoneFalse118739.550
293193496729NoneV-2 Pg No 17 Itm No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadSqm1623.091623.09976.79FalseNoneNoneFalseNoneFalse1585418.08110
293193596729NoneV-2 Pg No 17 Itm No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadSqm1367.851367.85150.83FalseNoneNoneFalseNoneFalse206312.81550
293193696729NoneV-2 Pg No 100 Itm No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadCum122431.78122431.781.77FalseNoneNoneFalseNoneFalse216704.25060
293193796729NoneV-2 Pg No 104 Itm No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadNo1258.821258.8220.0FalseNoneNoneFalseNoneFalse25176.40
293193896729NoneV-2 Pg No 218 Itm No 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm. GROUND FLOOR ---- etc.,complete with all leadNo681.45681.4540.0FalseNoneNoneFalseNoneFalse27258.00
293193996729NoneV-2 Pg No 219 Itm No 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm. GROUND FLOOR ---- etc.,complete with all leadNo464.62464.6220.0FalseNoneNoneFalseNoneFalse9292.40
293194096729NoneV-2 Pg No 219 Itm No 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm. GROUND FLOOR ---- etc.,complete with all leadNo185.85185.8540.0FalseNoneNoneFalseNoneFalse7434.00
293194196729NoneV-2 Pg No 219 Itm No 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm. GROUND FLOOR ---- etc.,complete with all leadNo86.7386.7380.0FalseNoneNoneFalseNoneFalse6938.40
293194296729NoneV-2 Pg No 219 Itm No 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm. GROUND FLOOR ---- etc.,complete with all leadNo123.9123.920.0FalseNoneNoneFalseNoneFalse2478.00
293194396729NoneV-2 Pg No 105 Itm No 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GROUND FLOOR ---- etc.,complete with all leadNo1303.421303.4220.0FalseNoneNoneFalseNoneFalse26068.40
293194496729NoneV-2 Pg No 69 Itm No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm. GROUND FLOOR ---- etc.,complete with all leadNo74.3474.34120.0FalseNoneNoneFalseNoneFalse8920.80
293194596729None034Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadm14.9914.99180.0FalseNoneNoneFalseNoneFalse2698.20
293194696729NoneV-2 Pg No 105 Itm No 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial. GROUNDFLOOR ---- etc.,complete with all leadSqm4115.954115.9558.32FalseNoneNoneFalseNoneFalse240042.2040
293194796729NoneV-2 Pg No 110 Itm No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). GROUND FLOOR ---- etc.,complete with all leadSqm8343.428343.4252.5FalseNoneNoneFalseNoneFalse438029.550
293194896729NoneV-2 Pg No 109 Itm No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR ---- etc.,complete with all leadSqm7085.847085.844.86FalseNoneNoneFalseNoneFalse34437.18240
293194996729NoneV-2 Pg No 86 Itm No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. GROUND FLOOR ---- etc.,complete with all leadKg208.15208.151204.56FalseNoneNoneFalseNoneFalse250729.1640
293195096729NoneV-2 Pg No 111 Itm No 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm. GROUND FLOOR ---- etc.,complete with all leadm869.77869.7799.4FalseNoneNoneFalseNoneFalse86455.1380
293195196729NoneV-2 Pg No 112 Itm No 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness. GROUND FLOOR ---- etc.,complete with all leadSqm4317.914317.9129.4FalseNoneNoneFalseNoneFalse126946.5540
293195296729NoneV-2 Pg No 107 Itm No 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GROUND FLOOR ---- etc.,complete with all leadNo1380.241380.2437.0FalseNoneNoneFalseNoneFalse51068.880
293195396729NoneV-2 Pg No 109 Itm No 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR ---- etc.,complete with all leadKg168.5168.586.4FalseNoneNoneFalseNoneFalse14558.40
293195496729NoneV-2 Pg No 41 Itm No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) GROUND FLOOR ---- etc.,complete with all leadSqm386.56386.561556.78FalseNoneNoneFalseNoneFalse601788.87680
293195596729NoneV-2 Pg No 43 Itm No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR ---- etc.,complete with all leadSqm261.42261.421071.99FalseNoneNoneFalseNoneFalse280239.62580
293195696729NoneV-2 Pg No 50 Itm No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR ---- etc.,complete with all leadSqm123.9123.92628.77FalseNoneNoneFalseNoneFalse325704.6030
293195796729NoneV-2 Pg No 42 Itm No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside). GROUND FLOOR ---- etc.,complete with all leadSqm432.41432.41458.28FalseNoneNoneFalseNoneFalse198164.85480
293195896729NoneV-2 Pg No 41 Itm No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. GROUND FLOOR ---- etc.,complete with all leadSqm438.6438.649.86FalseNoneNoneFalseNoneFalse21868.5960
293195996729NoneV-2 Pg No 43 Itm No 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide. GROUND FLOOR ---- etc.,complete with all leadm47.0847.08841.9FalseNoneNoneFalseNoneFalse39636.6520
293196096729None18-19 SR Page No 69 Item No 10.5.2Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc.,complete with all leadSqm283.2283.250.0FalseNoneNoneFalseNoneFalse14160.00
293196196729NoneV-2 Pg No 54 Itm No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. GROUND FLOOR ---- etc.,complete with all leadm64.4264.42540.08FalseNoneNoneFalseNoneFalse34791.95360
293196296729NoneV-2 Pg No 61 Itm No 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm. GROUND FLOOR ---- etc.,complete with all leadSqm1455.821455.82682.55FalseNoneNoneFalseNoneFalse993669.9410
293196396729NoneV-2 Pg No 59 Itm No 9.1Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. GROUND FLOOR ---- etc.,complete with all leadSqm558.78558.7828.28FalseNoneNoneFalseNoneFalse15802.29840
293196496729NoneV-2 Pg No 62 Itm No 9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm. GROUND FLOOR ---- etc.,complete with all leadSqm1642.911642.91455.1FalseNoneNoneFalseNoneFalse747688.3410
293196596729NoneV-2 Pg No 63 Itm No 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. Staircase 1-GROUND FLOOR ---- etc.,complete with all leadSqm3533.623533.6283.32FalseNoneNoneFalseNoneFalse294421.21840
293196696729NoneV-2 Pg No 64 Itm No 9.32Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. GROUND FLOOR ---- etc.,complete with all leadSqm3199.093199.0934.57FalseNoneNoneFalseNoneFalse110592.54130
293196796729NoneV-2 Pg No 41 Itm No 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc.,complete with all leadSqm365.5365.5592.5FalseNoneNoneFalseNoneFalse216558.750
293196896729NoneV-2 Pg No 150 Itm No 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis).GROUND FLOOR ---- etc.,complete with all leadSqm761.98761.9848.36FalseNoneNoneFalseNoneFalse36849.35280
293196996729NoneV-2 Pg No 60 Itm No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.GROUND FLOOR ---- etc.,complete with all leadSqm1101.471101.4727.51FalseNoneNoneFalseNoneFalse30301.43970
293197096729NoneV-2 Pg No 65 Itm No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.GROUND FLOOR ---- etc.,complete with all leadSqm1795.311795.31137.4FalseNoneNoneFalseNoneFalse246675.5940
293197196729NoneV-2 Pg No 85 Itm No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR ---- etc.,complete with all leadKg700.03700.03360.89FalseNoneNoneFalseNoneFalse252633.82670
293197296729NoneV-2 Pg No 48 Itm No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc.,complete with all leadSqm157.35157.352628.77FalseNoneNoneFalseNoneFalse413636.95950
293197396729NoneV-2 Pg No 46 Itm No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc.,complete with all leadSqm193.28193.28458.28FalseNoneNoneFalseNoneFalse88576.35840
293197496729NoneV-2 Pg No 47 Itm No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc.,complete with all leadSqm61.9561.9557.36FalseNoneNoneFalseNoneFalse3553.4520
293197596729NoneV-2 Pg No 48 Itm No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm142.48142.4864.44FalseNoneNoneFalseNoneFalse9181.41120
293197696729NoneV-2 Pg No 47 Itm No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR ---- etc.,complete with all leadSqm65.6665.66139.97FalseNoneNoneFalseNoneFalse9190.43020
293197796729NoneV-2 Pg No 54 Itm No 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.)GROUND FLOOR ---- etc.,complete with all leadSqm838.8838.8139.97FalseNoneNoneFalseNoneFalse117406.8360
293197896729NoneV-2 Pg No 181 Itm No 18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. GROUND FLOOR ---- etc.,complete with all leadKg504.27504.27304.2FalseNoneNoneFalseNoneFalse153398.9340
293197996729NoneV-2 Pg No 181 Itm No 18.2Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum- smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the cur- tain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in m2 . up to two decimal places.Note:-2. ---- etc.,complete with all leadSqm3326.713326.7140.2FalseNoneNoneFalseNoneFalse133733.7420
293198096729NoneV-2 Pg No 183 Itm No 18.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface No 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face No 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face No 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.GROUND FLOOR ---- etc.,complete with all leadSqm3770.273770.2740.2FalseNoneNoneFalseNoneFalse151564.8540
293198196729NoneV-2 Pg No 24 Itm No 7.28.1Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame for Flat surfaces ---- etc.,complete with all leadSqm1578.481578.48104.08FalseNoneNoneFalseNoneFalse164288.19840
293198296729NoneV-2 Pg No 28 Itm No 7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. GROUND FLOOR ---- etc.,complete with all leadSqm2097.622097.62156.11FalseNoneNoneFalseNoneFalse327459.45820
293198396729NoneV-2 Pg No 63 Itm No 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadSqm5335.135335.134.78FalseNoneNoneFalseNoneFalse25501.92140
293198496729None073Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc.,complete with all leadm2596.02596.040.0FalseNoneNoneFalseNoneFalse103840.00
293198596729NoneCPWD V-1 Pg No 205 Itm No 9.136Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). ALL FLOORS ---- etc.,complete with all leadm1541.111541.1130.0FalseNoneNoneFalseNoneFalse46233.30
293198696729NoneCPWD V-1 Pg No 205 Itm No 9.137Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). ALL FLOORS ---- etc.,complete with all leadSqm6790.216790.2112.96FalseNoneNoneFalseNoneFalse88001.12160
293198796729NoneV-2 Pg No 87 Itm No 11.35.1 1Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in- charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR ---- etc.,complete with all leadKg560.02560.0257.6FalseNoneNoneFalseNoneFalse32257.1520
293198896729NoneV-2 Pg No 89 Itm No 11.37.1Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ Sqm) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR ---- etc.,complete with all leadSqm1224.131224.135.76FalseNoneNoneFalseNoneFalse7050.98880
293198996729NoneV-2 Pg No 72 Itm No 10.19Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. GROUND FLOOR ---- etc.,complete with all leadSqm4469.074469.0712.0FalseNoneNoneFalseNoneFalse53628.840
293199096729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS-FIRST FLOOR ---- etc.,complete with all leadCum14557.5414557.5432.3FalseNoneNoneFalseNoneFalse470208.5420
293199196729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS and lintel-FIRST ROOF ---- etc.,complete with all leadCum13701.2113701.2162.93FalseNoneNoneFalseNoneFalse862217.14530
293199296729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB-FIRST ROOF ---- etc.,complete with all leadCum12844.8912844.89102.26FalseNoneNoneFalseNoneFalse1313518.45140
293199396729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. Staircase 1 No's-FIRST FLOOR ---- etc.,complete with all leadCum12416.7212416.728.72FalseNoneNoneFalseNoneFalse108273.79840
293199496729NoneV-1 Pg No 16 Itm No 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc.,complete with all leadCum9126.389126.384.46FalseNoneNoneFalseNoneFalse40703.65480
293199596729NoneV-1 Pg No 18 Itm No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc.,complete with all leadt111945.59111945.5929.81FalseNoneNoneFalseNoneFalse3337098.03790
293199696729NoneV-2 Pg No 17 Itm No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc.,complete with all leadSqm1639.321639.32790.7FalseNoneNoneFalseNoneFalse1296210.3240
293199796729NoneV-2 Pg No 17 Itm No 6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc.,complete with all leadSqm1381.531381.5364.28FalseNoneNoneFalseNoneFalse88804.74840
293199896729NoneV-2 Pg No 100 Itm No 12.13.1Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc.,complete with all leadCum123656.1123656.10.78FalseNoneNoneFalseNoneFalse96451.7580
293199996729NoneV-2 Pg No 104 Itm No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc.,complete with all leadNo1271.411271.4110.0FalseNoneNoneFalseNoneFalse12714.10
293200096729NoneV-2 Pg No 218 Itm No 22.15.2Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc.,complete with all leadNo688.26688.2620.0FalseNoneNoneFalseNoneFalse13765.20
293200196729NoneV-2 Pg No 219 Itm No 22.15.4Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc.,complete with all leadNo469.27469.2710.0FalseNoneNoneFalseNoneFalse4692.70
293200296729NoneV-2 Pg No 219 Itm No 22.15.6Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc.,complete with all leadNo187.7187.720.0FalseNoneNoneFalseNoneFalse3754.00
293200396729NoneV-2 Pg No 219 Itm No 22.15.9Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc.,complete with all leadNo87.5987.5940.0FalseNoneNoneFalseNoneFalse3503.60
293200496729NoneV-2 Pg No 219 Itm No 22.15.10Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc.,complete with all leadNo125.13125.1310.0FalseNoneNoneFalseNoneFalse1251.30
293200596729NoneV-2 Pg No 105 Itm No 12.6Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc.,complete with all leadNo1316.461316.4610.0FalseNoneNoneFalseNoneFalse13164.60
293200696729NoneV-2 Pg No 69 Itm No 10.6.3Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc.,complete with all leadNo75.0875.0860.0FalseNoneNoneFalseNoneFalse4504.80
293200796729NoneV-2 Pg No 105 Itm No 12.57.6Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc.,complete with all leadSqm4157.114157.1128.08FalseNoneNoneFalseNoneFalse116731.64880
293200896729NoneV-2 Pg No 110 Itm No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc.,complete with all leadSqm8426.868426.8667.5FalseNoneNoneFalseNoneFalse568813.050
293200996729NoneV-2 Pg No 109 Itm No 12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc.,complete with all leadSqm7156.697156.695.22FalseNoneNoneFalseNoneFalse37357.92180
293201096729NoneV-2 Pg No 86 Itm No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc.,complete with all leadKg210.23210.231527.12FalseNoneNoneFalseNoneFalse321046.43760
293201196729NoneV-2 Pg No 111 Itm No 12.93.1Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc.,complete with all leadm878.47878.4746.4FalseNoneNoneFalseNoneFalse40761.0080
293201296729NoneV-2 Pg No 112 Itm No 12.94.1Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc.,complete with all leadSqm4361.094361.0913.44FalseNoneNoneFalseNoneFalse58613.04960
293201396729NoneV-2 Pg No 105 Itm No 12.59Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc.,complete with all leadNo1394.041394.0418.0FalseNoneNoneFalseNoneFalse25092.720
293201496729NoneV-2 Pg No 84 Itm No 11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc.,complete with all leadKg170.18170.1886.4FalseNoneNoneFalseNoneFalse14703.5520
293201596729NoneV-2 Pg No 41 Itm No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc.,complete with all leadSqm390.43390.431211.25FalseNoneNoneFalseNoneFalse472908.33750
293201696729NoneV-2 Pg No 43 Itm No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm264.04264.041071.99FalseNoneNoneFalseNoneFalse283048.23960
293201796729NoneV-2 Pg No 50 Itm No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc.,complete with all leadSqm125.13125.132283.23FalseNoneNoneFalseNoneFalse285700.56990
293201896729NoneV-2 Pg No 42 Itm No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc.,complete with all leadSqm436.73436.73417.12FalseNoneNoneFalseNoneFalse182168.81760
293201996729NoneV-2 Pg No 41 Itm No 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc.,complete with all leadSqm442.99442.9951.78FalseNoneNoneFalseNoneFalse22938.02220
293202096729NoneV-2 Pg No 43 Itm No 8.16.2Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc.,complete with all leadm47.5547.55841.9FalseNoneNoneFalseNoneFalse40032.3450
293202196729NoneV-2 Pg No 23 Itm No 7.18Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc.,complete with all leadCum2524.052524.058.23FalseNoneNoneFalseNoneFalse20772.93150
293202296729NoneV-2 Pg No 150 Itm No 15.7Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc.,complete with all leadCum769.6769.646.7FalseNoneNoneFalseNoneFalse35940.320
293202396729NoneV-2 Pg No 54 Itm No 8.79Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc.,complete with all leadm65.0765.07540.08FalseNoneNoneFalseNoneFalse35143.00560
293202496729NoneV-2 Pg No 61 Itm No 9.17.2Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc.,complete with all leadSqm1470.381470.38608.3FalseNoneNoneFalseNoneFalse894432.1540
293202596729NoneV-2 Pg No 62 Itm No 9.22.2Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc.,complete with all leadSqm1659.341659.34168.33FalseNoneNoneFalseNoneFalse279316.70220
293202696729NoneV-2 Pg No 63 Itm No 9.24Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. ---- etc.,complete with all leadSqm3568.963568.9659.56FalseNoneNoneFalseNoneFalse212567.25760
293202796729NoneV-2 Pg No 41 Itm No 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm369.16369.16309.21FalseNoneNoneFalseNoneFalse114147.96360
293202896729NoneV-2 Pg No 60 Itm No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc.,complete with all leadSqm1112.481112.4827.41FalseNoneNoneFalseNoneFalse30493.07680
293202996729NoneV-2 Pg No 65 Itm No 9.39Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc.,complete with all leadSqm1813.261813.26140.88FalseNoneNoneFalseNoneFalse255452.06880
293203096729NoneV-2 Pg No 85 Itm No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc.,complete with all leadKg707.03707.03270.78FalseNoneNoneFalseNoneFalse191449.58340
293203196729NoneV-2 Pg No 48 Itm No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm158.92158.922283.23FalseNoneNoneFalseNoneFalse362850.91160
293203296729NoneV-2 Pg No 46 Itm No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm195.21195.21417.12FalseNoneNoneFalseNoneFalse81425.99520
293203396729NoneV-2 Pg No 47 Itm No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm62.5662.5672.72FalseNoneNoneFalseNoneFalse4549.36320
293203496729NoneV-2 Pg No 48 Itm No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm143.9143.972.72FalseNoneNoneFalseNoneFalse10464.4080
293203596729NoneV-2 Pg No 47 Itm No 8.34.1Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm66.3266.3267.4FalseNoneNoneFalseNoneFalse4469.9680
293203696729NoneV-2 Pg No 54 Itm No 8.82Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc.,complete with all leadSqm847.19847.1967.4FalseNoneNoneFalseNoneFalse57100.6060
293203796729NoneV-2 Pg No 181 Itm No 18.1Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc.,complete with all leadKg509.31509.31285.19FalseNoneNoneFalseNoneFalse145250.11890
293203896729NoneV-2 Pg No 181 Itm No 18.2Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum- smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/ structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer- in-Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the cur- tain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in m2 . up to two decimal places.Note:-2. ---- etc.,complete with all leadSqm3359.983359.9843.88FalseNoneNoneFalseNoneFalse147435.92240
293203996729NoneV-2 Pg No 183 Itm No 18.3Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface No 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face No 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face No 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc.,complete with all leadSqm3807.973807.9743.88FalseNoneNoneFalseNoneFalse167093.72360
293204096729NoneV-2 Pg No 24 Itm No 7.28.1Providing & fixing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame for Flat surfaces ---- etc.,complete with all leadSqm1594.271594.2733.92FalseNoneNoneFalseNoneFalse54077.63840
293204196729NoneV-2 Pg No 28 Itm No 7.41Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc.,complete with all leadSqm2118.62118.650.88FalseNoneNoneFalseNoneFalse107794.3680
293204296729NoneV-2 Pg No 63 Itm No 9.29Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc.,complete with all leadSqm5388.485388.483.36FalseNoneNoneFalseNoneFalse18105.29280
293204396729NoneV-2 Pg No 72 Itm No 10.19Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. ---- etc.,complete with all leadSqm4513.764513.7619.5FalseNoneNoneFalseNoneFalse88018.320
293204496729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS-HEAD ROOM ---- etc.,complete with all leadCum14701.6714701.6711.25FalseNoneNoneFalseNoneFalse165393.78750
293204596729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS and lintel-HEAD ROOF ---- etc.,complete with all leadCum13836.8713836.8716.57FalseNoneNoneFalseNoneFalse229276.93590
293204696729NoneV-1 Pg No 16 Itm No 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB-HEAD ROOM ---- etc.,complete with all leadCum12972.0612972.0621.44FalseNoneNoneFalseNoneFalse278120.96640
293204796729NoneV-1 Pg No 16 Itm No 2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc.,complete with all leadCum9216.749216.740.71FalseNoneNoneFalseNoneFalse6543.88540
293204896729NoneV-1 Pg No 18 Itm No 2.11 aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc.,complete with all leadt113053.96113053.965.68FalseNoneNoneFalseNoneFalse642146.49280
293204996729NoneV-2 Pg No 17 Itm No 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc.,complete with all leadSqm1655.551655.55299.21FalseNoneNoneFalseNoneFalse495357.11550
293205096729NoneV-2 Pg No 110 Itm No 12.9Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc.,complete with all leadSqm8510.298510.299.0FalseNoneNoneFalseNoneFalse76592.610
293205196729NoneV-2 Pg No 86 Itm No 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc.,complete with all leadKg212.31212.31189.0FalseNoneNoneFalseNoneFalse40126.590
293205296729NoneV-2 Pg No 77 Itm No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc.,complete with all leadSqm5659.25659.25.76FalseNoneNoneFalseNoneFalse32596.9920
293205396729NoneV-2 Pg No 41 Itm No 8.4.2Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc.,complete with all leadSqm394.29394.29256.67FalseNoneNoneFalseNoneFalse101202.41430
293205496729NoneV-2 Pg No 43 Itm No 8.1Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm266.65266.65261.86FalseNoneNoneFalseNoneFalse69824.9690
293205596729NoneV-2 Pg No 50 Itm No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc.,complete with all leadSqm126.37126.37518.53FalseNoneNoneFalseNoneFalse65526.63610
293205696729NoneV-2 Pg No 42 Itm No 8.5.2Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc.,complete with all leadSqm441.05441.05479.16FalseNoneNoneFalseNoneFalse211333.5180
293205796729None146Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane. System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification. Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.TERRACE FLOOR ---- etc.,complete with all leadSqm1593.01593.0740.52FalseNoneNoneFalseNoneFalse1179648.360
293205896729NoneV-2 Pg No 48 Itm No 8.39Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm160.5160.5518.53FalseNoneNoneFalseNoneFalse83224.0650
293205996729NoneV-2 Pg No 46 Itm No 8.32Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm197.14197.14479.16FalseNoneNoneFalseNoneFalse94461.60240
293206096729NoneV-2 Pg No 47 Itm No 8.34.3Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm63.1863.1814.76FalseNoneNoneFalseNoneFalse932.53680
293206196729NoneV-2 Pg No 48 Itm No 8.4Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm145.33145.3314.76FalseNoneNoneFalseNoneFalse2145.07080
293206296729NoneV-5 Pg No 113 Itm No 10.1.7Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc.,complete with all leadm519.41519.41234.0FalseNoneNoneFalseNoneFalse121541.940
293206396729NoneV-1 Pg No 17 Itm No 2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. A. Raft ---- etc.,complete with all leadCum8732.838732.8330.63FalseNoneNoneFalseNoneFalse267486.58290
293206496729NoneV-1 Pg No 18 Itm No 2.11 hSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc.,complete with all leadt97894.6297894.6210.21FalseNoneNoneFalseNoneFalse999504.07020
293206596729NoneV-2 Pg No 77 Itm No 11.5.1Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc.,complete with all leadSqm5548.245548.244.2FalseNoneNoneFalseNoneFalse23302.6080
293206696729NoneV-2 Pg No 152 Itm No 15.14UGT/OHT (inside) waterproofing with Anti-microbial Coating---Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 - 300 of US - FDA, having mixing Ratio (Base: Hardener: Water) - 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. ---- etc.,complete with all leadSqm2072.842072.84186.24FalseNoneNoneFalseNoneFalse386045.72160
293206796729NoneV-2 Pg No 42 Itm No 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm459.66459.66582.24FalseNoneNoneFalseNoneFalse267632.43840
293206896729NoneV-2 Pg No 44 Itm No 8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm32.2132.21511.12FalseNoneNoneFalseNoneFalse16463.17520
293206996729NoneV-2 Pg No 45 Itm No 8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc.,complete with all leadSqm110.27110.27511.12FalseNoneNoneFalseNoneFalse56361.20240
293207096729NoneV-5 Pg No 221 Itm No 18.3Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc.,complete with all leadNo2430.912430.914.0FalseNoneNoneFalseNoneFalse9723.640
293207196729None160Modular - ETP : Consists of MS fabricated ETP plant, effluent transfer pumps, effluent agitator, sludge disposal pump, chemical dosing pumps, MCC panel complete - ---- etc.,complete with all leadEach1743239.961743239.961.0FalseNoneNoneFalseNoneFalse1743239.960
293207296729None161The Tenderer (agency) should arrange to obtain (get), Detailed Architectural drawings and Elevations, Structural designs and drawings including Soil exploration & proof checking by reputed Government/Semi Government / IISC/ITT/REC or decided by the Department and the same has to be furnished to the Department for approval and Providing Consultancy for Architectural design and drawings floor wise. Elevation drawings, 3D view, MFP design and Drawings, Fire Fighting, Internal and External Electrical services including electrical infrastructure, Telephone & Networking, Fire fighting, Modular OT, MGPL, interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. ---- ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. ---- etc.,complete with all leadJob933774.5933774.51.0FalseNoneNoneFalseNoneFalse933774.50
17097048010000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(Electrical work-Internal / External Electrification, Lift, UPS System, Telephone & Networking, CCTV System)14109649.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293207396730NoneV-6Pg No 5 Itm No 2.2.1Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch ---- etc.,complete with all leadPoint333.29333.2932.0FalseNoneNoneFalseNoneFalse10665.280
293207496730NoneV-6 Pg No 5 Itm No 2.2.2Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc.,complete with all leadPoint469.58469.5860.0FalseNoneNoneFalseNoneFalse28174.80
293207596730NoneV-6 Pg No 5 Itm No 2.2.3Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc.,complete with all leadPoint687.64687.64100.0FalseNoneNoneFalseNoneFalse68764.00
293207696730NoneV-6 Pg No 5 Itm No 2.2.4Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches ---- etc.,complete with all leadPoint838.8838.830.0FalseNoneNoneFalseNoneFalse25164.00
293207796730NoneV-6 Pg No 5 Itm No 2.2.5Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches ---- etc.,complete with all leadPoint1225.371225.3710.0FalseNoneNoneFalseNoneFalse12253.70
293207896730NoneV-6 Pg No 8 Itm No 3.4.1Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc.,complete with all leadEach170.98170.9850.0FalseNoneNoneFalseNoneFalse8549.00
293207996730NoneV-6 Pg No 8 Itm No 3.4.2Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc.,complete with all leadEach197.0197.0100.0FalseNoneNoneFalseNoneFalse19700.00
293208096730NoneV-6 Pg No 8 Itm No 3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc.,complete with all leadEach219.3219.360.0FalseNoneNoneFalseNoneFalse13158.00
293208196730NoneV-6 Pg No 8 Itm No 3.4.4Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc.,complete with all leadEach272.58272.5850.0FalseNoneNoneFalseNoneFalse13629.00
293208296730NoneV-6 Pg No 8 Itm No 3.4.5Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc.,complete with all leadEach323.37323.3765.0FalseNoneNoneFalseNoneFalse21019.050
293208396730NoneV-6 Pg No 8 Itm No 3.4.6Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc.,complete with all leadEach395.24395.24110.0FalseNoneNoneFalseNoneFalse43476.40
293208496730NoneV-6 Pg No 8 Itm No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc.,complete with all leadEach169.74169.7450.0FalseNoneNoneFalseNoneFalse8487.00
293208596730NoneV-6 Pg No 8 Itm No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc.,complete with all leadEach199.47199.47150.0FalseNoneNoneFalseNoneFalse29920.50
293208696730NoneV-6 Pg No 8 Itm No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc.,complete with all leadEach216.82216.8260.0FalseNoneNoneFalseNoneFalse13009.20
293208796730NoneV-6 Pg No 8 Itm No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc.,complete with all leadEach289.92289.9250.0FalseNoneNoneFalseNoneFalse14496.00
293208896730NoneV-6 Pg No 8 Itm No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc.,complete with all leadEach351.87351.8765.0FalseNoneNoneFalseNoneFalse22871.550
293208996730NoneV-6 Pg No 8 Itm No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc.,complete with all leadEach426.21426.21110.0FalseNoneNoneFalseNoneFalse46883.10
293209096730NoneV-6 Pg No 9 Itm No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc.,complete with all leadEach126.37126.37452.0FalseNoneNoneFalseNoneFalse57119.240
293209196730NoneV-6 Pg No 9 Itm No 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc.,complete with all leadEach205.67205.678.0FalseNoneNoneFalseNoneFalse1645.360
293209296730NoneV-6 Pg No 9 Itm No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc.,complete with all leadEach211.86211.86220.0FalseNoneNoneFalseNoneFalse46609.20
293209396730NoneV-6 Pg No 9 Itm No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc.,complete with all leadEach442.32442.3245.0FalseNoneNoneFalseNoneFalse19904.40
293209496730NoneV-6 Pg No 9 Itm No 3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc.,complete with all leadEach403.91403.9130.0FalseNoneNoneFalseNoneFalse12117.30
293209596730NoneV-6 Pg No 9 Itm No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc.,complete with all leadEach292.4292.460.0FalseNoneNoneFalseNoneFalse17544.00
293209696730NoneV-6 Pg No 9 Itm No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc.,complete with all leadEach223.02223.0230.0FalseNoneNoneFalseNoneFalse6690.60
293209796730NoneV-6 Pg No 4 Itm No 1.13Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc.,complete with all leadNo144.96144.9645.0FalseNoneNoneFalseNoneFalse6523.20
293209896730NoneV-6 Pg No 21 Itm No 5.45.2Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20Amps ---- etc.,complete with all leadEach1203.061203.064.0FalseNoneNoneFalseNoneFalse4812.240
293209996730NoneV-6 Pg No 21 Itm No 5.45.4Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30Amps ---- etc.,complete with all leadEach2106.32106.34.0FalseNoneNoneFalseNoneFalse8425.20
293210096730NoneV-6 Pg No 2 Itm No 1.2.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc.,complete with all leadm81.7781.772000.0FalseNoneNoneFalseNoneFalse163540.00
293210196730NoneV-6 Pg No 2 Itm No 1.2.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc.,complete with all leadm96.6496.645300.0FalseNoneNoneFalseNoneFalse512192.00
293210296730NoneV-6 Pg No 2 Itm No 1.2.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc.,complete with all leadm127.61127.61500.0FalseNoneNoneFalseNoneFalse63805.00
293210396730NoneV-6 Pg No 2 Itm No 1.3.1Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc.,complete with all leadm84.2584.251000.0FalseNoneNoneFalseNoneFalse84250.00
293210496730NoneV-6 Pg No 2 Itm No 1.3.2Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc.,complete with all leadm97.8897.881800.0FalseNoneNoneFalseNoneFalse176184.00
293210596730NoneV-6 Pg No 2 Itm No 1.3.3Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc.,complete with all leadm122.66122.66200.0FalseNoneNoneFalseNoneFalse24532.00
293210696730NoneV-6 Pg No 5 Itm No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm ---- etc.,complete with all leadm32.2132.211500.0FalseNoneNoneFalseNoneFalse48315.00
293210796730NoneV-6 Pg No 5 Itm No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm ---- etc.,complete with all leadm52.0352.034800.0FalseNoneNoneFalseNoneFalse249744.00
293210896730NoneV-6 Pg No 5 Itm No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm ---- etc.,complete with all leadm78.0578.052800.0FalseNoneNoneFalseNoneFalse218540.00
293210996730NoneV-6 Pg No 5 Itm No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm ---- etc.,complete with all leadm113.98113.981800.0FalseNoneNoneFalseNoneFalse205164.00
293211096730NoneV-6 Pg No 18 Itm No 5.19.11Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc.,complete with all leadEach5003.085003.085.0FalseNoneNoneFalseNoneFalse25015.40
293211196730NoneV-6 Pg No 18 Itm No 5.19.12Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc.,complete with all leadEach6120.666120.665.0FalseNoneNoneFalseNoneFalse30603.30
293211296730NoneV-6 Pg No 18 Itm No 5.19.9Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc.,complete with all leadEach2885.632885.632.0FalseNoneNoneFalseNoneFalse5771.260
293211396730NoneV-6 Pg No 17 Itm No 5.18.1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc.,complete with all leadEach514.18514.18177.0FalseNoneNoneFalseNoneFalse91009.860
293211496730NoneV-6 Pg No 17 Itm No 5.18.8Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc.,complete with all leadEach3771.513771.519.0FalseNoneNoneFalseNoneFalse33943.590
293211596730NoneV-6 Pg No 18 Itm No 5.18.9Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc.,complete with all leadEach3826.033826.0324.0FalseNoneNoneFalseNoneFalse91824.720
293211696730NoneV-6 Pg No 18 Itm No 5.20.8Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc.,complete with all leadEach6377.136377.1310.0FalseNoneNoneFalseNoneFalse63771.30
293211796730NoneV-6 Pg No 18 Itm No 5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole ---- etc.,complete with all leadEach5299.25299.22.0FalseNoneNoneFalseNoneFalse10598.40
293211896730NoneV-6 Pg No 13 Itm No 32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc.,complete with all leadKm109549.9109549.90.3FalseNoneNoneFalseNoneFalse32864.970
293211996730NoneV-6 Pg No 13 Itm No 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc.,complete with all leadKm172901.21172901.210.3FalseNoneNoneFalseNoneFalse51870.3630
293212096730NoneV-6 Pg No 13 Itm No 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc.,complete with all leadKm190882.81190882.810.1FalseNoneNoneFalseNoneFalse19088.2810
293212196730NoneV-6 Pg No 13 Itm No 32.131.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc.,complete with all leadKm393892.96393892.960.1FalseNoneNoneFalseNoneFalse39389.2960
293212296730NoneV-6 Pg No 13 Itm No 32.141.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm ---- etc.,complete with all leadKm462413.38462413.380.1FalseNoneNoneFalseNoneFalse46241.3380
293212396730NoneV-6 Pg No 13 Itm No 32.171.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 185 sqmm ---- etc.,complete with all leadKm856419.1856419.10.25FalseNoneNoneFalseNoneFalse214104.7750
293212496730NoneV-6 Pg No 52 Itm No 31.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc.,complete with all leadKm25877.7525877.750.6FalseNoneNoneFalseNoneFalse15526.650
293212596730NoneV-6 Pg No 52 Itm No 31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc.,complete with all leadKm38581.2238581.220.3FalseNoneNoneFalseNoneFalse11574.3660
293212696730NoneV-6 Pg No 52 Itm No 31.07Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 sqmm to 300 sqmm ---- etc.,complete with all leadKm39992.4439992.440.25FalseNoneNoneFalseNoneFalse9998.110
293212796730NonePWD SR 19-20 Page No Item No 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc.,complete with all leadEach144.96144.9660.0FalseNoneNoneFalseNoneFalse8697.60
293212896730NonePWD SR 19-20 Page No Item No 6.11.6Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia ---- etc.,complete with all leadEach480.73480.738.0FalseNoneNoneFalseNoneFalse3845.840
293212996730NonePWD SR 19-20 Page No Item No 6.17.6Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc.,complete with all leadEach15.4115.4124.0FalseNoneNoneFalseNoneFalse369.840
293213096730NonePWD SR 19-20 Page No Item No 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc.,complete with all leadEach39.6439.6416.0FalseNoneNoneFalseNoneFalse634.240
293213196730NonePWD SR 19-20 Page No Item No 6.17.10Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc.,complete with all leadEach148.68148.6816.0FalseNoneNoneFalseNoneFalse2378.880
293213296730NonePWD SR 19-20 Page No Item No 6.17.11Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 95 sqmm Long Barrel ---- etc.,complete with all leadEach185.85185.8516.0FalseNoneNoneFalseNoneFalse2973.60
293213396730NonePWD SR 19-20 Page No Item No 6.17.14Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm Long Barrel ---- etc.,complete with all leadEach405.15405.1524.0FalseNoneNoneFalseNoneFalse9723.60
293213496730NoneV-6 Pg No 54 Itm No 12.56Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc.,complete with all leadNo4348.894348.8922.0FalseNoneNoneFalseNoneFalse95675.580
293213596730NoneV-6 Pg No 54 Itm No 12.58.2Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc.,complete with all leadm101.59101.59120.0FalseNoneNoneFalseNoneFalse12190.80
293213696730NoneV-6 Pg No 55 Itm No 12.58.7Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 25x6mm Copper strip ---- etc.,complete with all leadm706.23706.2380.0FalseNoneNoneFalseNoneFalse56498.40
293213796730NoneV-6 Pg No 55 Itm No 12.58.11Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate ---- etc.,complete with all leadEach9194.619194.6122.0FalseNoneNoneFalseNoneFalse202281.420
293213896730NoneV-6 Pg No 44 Itm No 11.5.2Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc.,complete with all leadEach1096.511096.5135.0FalseNoneNoneFalseNoneFalse38377.850
293213996730NoneV-6 Pg No 43 Itm No 11.3.2Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc.,complete with all leadEach854.91854.91124.0FalseNoneNoneFalseNoneFalse106008.840
293214096730NoneV-6 Pg No 47 Itm No 11.11.3Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per watt, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc.,complete with all leadEach184.61184.6120.0FalseNoneNoneFalseNoneFalse3692.20
293214196730NoneV-6 Pg No 47 Itm No 11.11.5Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than80 lumen per watt, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc.,complete with all leadEach333.29333.2910.0FalseNoneNoneFalseNoneFalse3332.90
293214296730NoneV-6 Pg No 45 Itm No 11.6.3Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than100 lumen per watt, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt ---- etc.,complete with all leadEach5641.165641.1630.0FalseNoneNoneFalseNoneFalse169234.80
293214396730NoneV-6 Pg No 46 Itm No 11.8.2Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencygreater than130lm/w, nominal CRI greater than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts ---- etc.,complete with all leadNo4985.734985.734.0FalseNoneNoneFalseNoneFalse19942.920
293214496730NoneV-6 Pg No 30 Itm No 6.1Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc.,complete with all leadEach1848.581848.5814.0FalseNoneNoneFalseNoneFalse25880.120
293214596730NoneV-6 Pg No 30 Itm No 6.4.1Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc.,complete with all leadEach3316.83316.845.0FalseNoneNoneFalseNoneFalse149256.00
293214696730NoneV-6 Pg No 30 Itm No 6.5.1Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep ---- etc.,complete with all leadEach3087.583087.584.0FalseNoneNoneFalseNoneFalse12350.320
293214796730NoneV-6 Pg No 52 Itm No 12.46Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc.,complete with all leadEach78.0578.0530.0FalseNoneNoneFalseNoneFalse2341.50
293214896730NoneV-6 Pg No 56 Itm No 13.7.1Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc.,complete with all leadEach151.15151.15189.0FalseNoneNoneFalseNoneFalse28567.350
293214996730NoneV-6 Pg No 57 Itm No 13.11Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. ---- etc.,complete with all leadEach390.28390.2849.0FalseNoneNoneFalseNoneFalse19123.720
293215096730NoneV-6 Pg No 57 Itm No 13.13Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc.,complete with all leadEach875.97875.9714.0FalseNoneNoneFalseNoneFalse12263.580
293215196730NoneV-6 Pg No 56 Itm No 13.4.1Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length ---- etc.,complete with all leadEach1810.171810.174.0FalseNoneNoneFalseNoneFalse7240.680
293215296730NoneV-6 Pg No 56 Itm No 13.5Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc.,complete with all leadEach200.71200.714.0FalseNoneNoneFalseNoneFalse802.840
293215396730NoneV-6 Pg No 31 Itm No 6.8.5Supplying of... TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 1.5 ton capacity ---- etc.,complete with all leadEach69823.8469823.845.0FalseNoneNoneFalseNoneFalse349119.20
293215496730NoneV-6 Pg No 31 Itm No 6.8.6Supplying of... TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 2 ton capacity ---- etc.,complete with all leadEach83507.3683507.365.0FalseNoneNoneFalseNoneFalse417536.80
293215596730NoneV-6 Pg No 32 Itm No 6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- etc.,complete with all leadEach3933.823933.8210.0FalseNoneNoneFalseNoneFalse39338.20
293215696730NoneV-6 Pg No 38 Itm No 9.1.1Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 3 KVA Capacity ---- etc.,complete with all leadEach4949.84949.85.0FalseNoneNoneFalseNoneFalse24749.00
293215796730NoneV-6 Pg No 38 Itm No 9.1.2Supplying, erecting, testing and commissioning of voltage stabilizer suitable for 170 to 270 v in put and load variation from no load to full load, with over load protection, spike suppression, operating at 00 C to 400 C. Range etc., complete. 4 KVA Capacity ---- etc.,complete with all leadEach5937.285937.285.0FalseNoneNoneFalseNoneFalse29686.40
293215896730NoneV-6 Pg No 31 Itm No 6.9.2Supply erection, testing, commissioning of Cassette type split Air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit/3 TR Cassette 3 Ph ---- etc.,complete with all leadEach130239.96130239.964.0FalseNoneNoneFalseNoneFalse520959.840
293215996730NoneV-6 Pg No 32 Itm No 6.13.2Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube.Cassette ---- etc.,complete with all leadm2030.722030.7260.0FalseNoneNoneFalseNoneFalse121843.20
293216096730NoneV-6 Pg No 20 Itm No 5.42.2Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc.,complete with all leadSq CM0.530.531112000.0FalseNoneNoneFalseNoneFalse589360.00
293216196730NoneV-6 Pg No 20 Itm No 5.40.2Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc.,complete with all leadm4255.964255.9616.0FalseNoneNoneFalseNoneFalse68095.360
293216296730NoneV-6 Pg No 20 Itm No 5.41.1Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc.,complete with all leadm377.89377.8984.0FalseNoneNoneFalseNoneFalse31742.760
293216396730NoneV-6 Pg No 20 Itm No 5.41.4Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc.,complete with all leadm936.68936.6884.0FalseNoneNoneFalseNoneFalse78681.120
293216496730NoneV-6 Pg No 17 Itm No 5.15.15Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 250Amps 35kA ---- etc.,complete with all leadEach29172.2529172.252.0FalseNoneNoneFalseNoneFalse58344.50
293216596730NoneV-6 Pg No 16 Itm No 5.14.9Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 100Amps 25kA ---- etc.,complete with all leadEach10515.3910515.3910.0FalseNoneNoneFalseNoneFalse105153.90
293216696730NoneV-6 Pg No 19 Itm No 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc.,complete with all leadEach11541.2811541.285.0FalseNoneNoneFalseNoneFalse57706.40
293216796730NoneV-6 Pg No 19 Itm No 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc.,complete with all leadEach638.08638.0827.0FalseNoneNoneFalseNoneFalse17228.160
293216896730NoneV-6 Pg No 19 Itm No 5.34Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc.,complete with all leadEach696.31696.3115.0FalseNoneNoneFalseNoneFalse10444.650
293216996730NoneV-6 Pg No 22 Itm No 5.51.4Supply and fixing of fully Enclosed 250A Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts ---- etc.,complete with all leadEach129896.76129896.761.0FalseNoneNoneFalseNoneFalse129896.760
293217096730NoneV-6 Pg No 20 Itm No 5.40.1Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x10mm Aluminum Strips ---- etc.,complete with all leadm3054.133054.1322.0FalseNoneNoneFalseNoneFalse67190.860
293217196730NoneV-6 Pg No 19 Itm No 5.39Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. ---- etc.,complete with all leadEach26811.9626811.961.0FalseNoneNoneFalseNoneFalse26811.960
293217296730NoneV-6 Pg No 19 Itm No 5.37Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc.,complete with all leadKvar594.72594.7230.0FalseNoneNoneFalseNoneFalse17841.60
293217396730NoneV-6 Pg No 16 Itm No 5.14.1Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc.,complete with all leadEach2738.192738.196.0FalseNoneNoneFalseNoneFalse16429.140
293217496730NoneV-6 Pg No 17 Itm No 5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc.,complete with all leadEach915.62915.624.0FalseNoneNoneFalseNoneFalse3662.480
293217596730NoneV-6 Pg No 59 Itm No 14.4.6Design, supplying, erecting testing and commissioning of - 20Passenger/ Bed-cum-passenger hospital lift(2 stops/2 Opening) with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc.,complete with all leadEach3572668.863572668.861.0FalseNoneNoneFalseNoneFalse3572668.860
293217696730None104Supply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 20KVA UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 15 minutes back up on 20kva load with required VRLA SMF individual Battery bank System housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more. ---- etc.,complete with all leadEach472000.0472000.01.0FalseNoneNoneFalseNoneFalse472000.00
293217796730NoneV-6 Pg No 9 Itm No 3.6.12RJ45/ I.O. outlet Cat 6 ---- etc.,complete with all leadEach417.54417.5425.0FalseNoneNoneFalseNoneFalse10438.50
293217896730NoneV-6 Pg No 9 Itm No 3.6.11Telephone socket ---- etc.,complete with all leadEach193.28193.2818.0FalseNoneNoneFalseNoneFalse3479.040
293217996730NoneV-6 Pg No 36 Itm No 8.1Supplying and drawing UTP-CAT 6E LAN cable. ---- etc.,complete with all leadm47.0847.081800.0FalseNoneNoneFalseNoneFalse84744.00
293218096730NoneV-6 Pg No 36 Itm No 8.10.1Supplying & Fixing of I/O Socket with back box Single I/O ---- etc.,complete with all leadEach607.11607.1125.0FalseNoneNoneFalseNoneFalse15177.750
293218196730NoneV-6 Pg No 36 Itm No 8.4.3Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth ---- etc.,complete with all leadEach10501.7610501.763.0FalseNoneNoneFalseNoneFalse31505.280
293218296730NoneV-6 Pg No 36 Itm No 8.9.11Supplying fixing of Network Switches. 16 port 10/100/1000 Switch ---- etc.,complete with all leadEach7979.167979.162.0FalseNoneNoneFalseNoneFalse15958.320
293218396730NoneV-6 Pg No 37 Itm No 8.11.1Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc.,complete with all leadEach318.42318.4225.0FalseNoneNoneFalseNoneFalse7960.50
293218496730NoneV-6 Pg No 37 Itm No 8.12.3Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc.,complete with all leadEach3778.953778.952.0FalseNoneNoneFalseNoneFalse7557.90
293218596730NoneV-6 Pg No 36 Itm No 8.2.2Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc.,complete with all leadm26.0126.01600.0FalseNoneNoneFalseNoneFalse15606.00
293218696730NoneV-6 Pg No 37 Itm No 8.13.2Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair ---- etc.,complete with all leadEach474.53474.531.0FalseNoneNoneFalseNoneFalse474.530
293218796730None115EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 50 Ports Providing PRI cards for Trunk lines / for tie line with reqd.software 16Analog Trunk Lines 4 Digital Extensions 20 Analogue Extensions( Expandable up to 50) In-Built Voicemail ( 4 Port & 80 Min) LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold . ---- etc.,complete with all leadNo141600.0141600.01.0FalseNoneNoneFalseNoneFalse141600.00
293218896730None116TELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc.,complete with all leadNo2124.02124.018.0FalseNoneNoneFalseNoneFalse38232.00
293218996730None117Supply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable (SM) ---- etc.,complete with all leadm115.64115.64100.0FalseNoneNoneFalseNoneFalse11564.00
293219096730None118IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc.,complete with all leadEach23836.023836.08.0FalseNoneNoneFalseNoneFalse190688.00
293219196730None119IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm 13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc.,complete with all leadEach25606.025606.04.0FalseNoneNoneFalseNoneFalse102424.00
293219296730None120Supplying, installation, testing and commissioning of SITC of complete 16 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc.,complete with all leadEach165200.0165200.01.0FalseNoneNoneFalseNoneFalse165200.00
293219396730None121Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc.,complete with all leadEach17110.017110.03.0FalseNoneNoneFalseNoneFalse51330.00
293219496730None122Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc.,complete with all leadEach47495.047495.01.0FalseNoneNoneFalseNoneFalse47495.00
293219596730None123Supply and Installation of I/Os ---- etc.,complete with all leadEach147.5147.540.0FalseNoneNoneFalseNoneFalse5900.00
293219696730None124Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc.,complete with all leadEach265.5265.518.0FalseNoneNoneFalseNoneFalse4779.00
293219796730None125Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc.,complete with all leadEach336.3336.318.0FalseNoneNoneFalseNoneFalse6053.40
293219896730None126Supply and Installation of 6 Core Single Mode Ofc Cable The rate shall include all mounting accessories complete as required ---- etc.,complete with all leadm115.64115.6450.0FalseNoneNoneFalseNoneFalse5782.00
293219996730None127Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc.,complete with all leadEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
293220096730NoneV-6 Pg No 37 Itm No 8.12.2Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc.,complete with all leadEach5079.95079.91.0FalseNoneNoneFalseNoneFalse5079.90
293220196730NoneV-6 Pg No 75 Itm No 56.3100 kVA, 11 kV/433 V, 3 phase Dyn11 : Supply and Erection of of Auxiliary Transformer with copper windings & oil, cable termination type on both HT & LT outdoor type ---- etc.,complete with all leadEach455689.33455689.331.0FalseNoneNoneFalseNoneFalse455689.330
293220296730NoneV-6 Pg No 54 Itm No 12.58.3Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc.,complete with all leadm158.59158.59100.0FalseNoneNoneFalseNoneFalse15859.00
293220396730NoneV-6 Pg No 55 Itm No 12.58.9Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc.,complete with all leadm2035.672035.67100.0FalseNoneNoneFalseNoneFalse203567.00
293220496730NoneV-6 Pg No 20 Itm No 45.07Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc.,complete with all leadSet5039.015039.014.0FalseNoneNoneFalseNoneFalse20156.040
293220596730NoneV-6 Pg No 20 Itm No 45.04Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc.,complete with all leadSet3887.983887.982.0FalseNoneNoneFalseNoneFalse7775.960
293220696730NoneV-6 Pg No 15 Itm No 36.0111 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc.,complete with all leadKm1102296.171102296.170.1FalseNoneNoneFalseNoneFalse110229.6170
293220796730NoneV-6 Pg No 16 Itm No 38Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc.,complete with all leadSqm1222.891222.89120.0FalseNoneNoneFalseNoneFalse146746.80
293220896730NoneV-6 Pg No 42 Itm No 10.1.8Supplying, installing, testing and commissioning of 82.5KVA/66kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines. ---- etc.,complete with all leadSet973837.89973837.891.0FalseNoneNoneFalseNoneFalse973837.890
293220996730NoneV-6 Pg No 42 Itm No 10.2.4Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 82.5 KVA ---- etc.,complete with all leadEach135708.9135708.91.0FalseNoneNoneFalseNoneFalse135708.90
293221096730None138Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc.,complete with all leadm3540.03540.010.0FalseNoneNoneFalseNoneFalse35400.00
293221196730None139Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc.,complete with all leadm236.0236.0100.0FalseNoneNoneFalseNoneFalse23600.00
17097048020000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(HVAC)7123916.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293221296731NoneV-6 Pg No 31 Itm No 6.8.4Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit. 5 Star- 1.0 Ton Capacity. ---- etc.,complete with all leadNo58923.1258923.123.0FalseNoneNoneFalseNoneFalse176769.360
293221396731NoneV-6 Pg No 31 Itm No 6.8.5Supplying of... TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 1.5 ton capacity ---- etc.,complete with all leadEach69823.8469823.843.0FalseNoneNoneFalseNoneFalse209471.520
293221496731NoneV-6 Pg No 31 Itm No 6.8.6Supplying of... TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube.(High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5 star 2 ton capacity ---- etc.,complete with all leadEach83507.3683507.362.0FalseNoneNoneFalseNoneFalse167014.720
293221596731NoneV-6 Pg No 32 Itm No 6.12Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split/cassette type A/C. ---- etc.,complete with all leadEach3933.823933.828.0FalseNoneNoneFalseNoneFalse31470.560
293221696731NoneV-6 Pg No 32 Itm No 6.13.1Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube. Split ---- etc.,complete with all leadm1919.211919.21240.0FalseNoneNoneFalseNoneFalse460610.40
293221796731NoneV-6 Pg No 33 Itm No 6.25.1Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials. 24 Gauge ---- etc.,complete with all leadSqm2243.822243.82237.0FalseNoneNoneFalseNoneFalse531785.340
293221896731NoneV-6 Pg No 33 Itm No 6.25.2Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials. 22 Gauge ---- etc.,complete with all leadSqm2627.912627.9125.0FalseNoneNoneFalseNoneFalse65697.750
293221996731NoneV-6 Pg No 33 Itm No 6.26Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts. ---- etc.,complete with all leadSqm1475.641475.64250.0FalseNoneNoneFalseNoneFalse368910.00
293222096731NoneV-6 Pg No 33 Itm No 6.27Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories. ---- etc.,complete with all leadNo5654.795654.795.0FalseNoneNoneFalseNoneFalse28273.950
293222196731NoneV-6 Pg No 33 Itm No 6.29.1Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. Aluminium Diffusers ---- etc.,complete with all leadNo6291.646291.6460.0FalseNoneNoneFalseNoneFalse377498.40
293222296731NoneV-6 Pg No 33 Itm No 6.29.2Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. Collar Dampers ---- etc.,complete with all leadNo3251.133251.1330.0FalseNoneNoneFalseNoneFalse97533.90
293222396731NoneV-6 Pg No 33 Itm No 6.29.3Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. GI Mixing Box ---- etc.,complete with all leadNo7774.727774.7230.0FalseNoneNoneFalseNoneFalse233241.60
293222496731NoneV-6 Pg No 33 Itm No 6.29.4Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air. Flexible Duct Per Mtr ---- etc.,complete with all leadNo2096.382096.3830.0FalseNoneNoneFalseNoneFalse62891.40
293222596731NoneV-6 Pg No 33 Itm No 6.30.2Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware etc.,. Complete. 6" Extruded aluminium grille with 15 deg to 30 deg louvers. ---- etc.,complete with all leadm2108.772108.7710.0FalseNoneNoneFalseNoneFalse21087.70
293222696731None015Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48Plus or minus 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with greater than75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec.Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns as per IS 7613,.The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type.The AHU to be selected that the noise level not to exceed 60 dBA at 1.5meter distance from the AHU cabinet in all directions. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, power & communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads,with nitrile rubber insulation, UPVC drain piping and termination, valves and insulation and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 3.0 TR / 1,200 CFM with 50 TSP - 0.75 Kw for CSU's and 1x3.0 - Condensing units with necessary KIT ---- etc.,complete with all leadNo195880.0195880.02.0FalseNoneNoneFalseNoneFalse391760.00
293222796731None016Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48 plus or minus 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with greater than75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec.Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns as per IS 7613,.The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type.The AHU to be selected that the noise level not to exceed 60 dBA at 1.5meter distance from the AHU cabinet in all directions. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, power & communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads,with nitrile rubber insulation, UPVC drain piping and termination, valves and insulation and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 4.5 TR / 1,600 CFM with 50 TSP - 1.5 Kw for CSU's and 1x5.5 - Condensing units with necessary KIT. (Location - As per the site condition) ---- etc.,complete with all leadNo283200.0283200.01.0FalseNoneNoneFalseNoneFalse283200.00
293222896731None017Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48Plus or minus 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with greater than75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec.Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns as per IS 7613,.The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type.The AHU to be selected that the noise level not to exceed 60 dBA at 1.5meter distance from the AHU cabinet in all directions. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, power & communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads,with nitrile rubber insulation, UPVC drain piping and termination, valves and insulation and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 8.5 TR / 3,400 CFM with 50 TSP - 1.5 Kw for CSU's and 1x8.5 - Condensing units with necessary KIT. (Location - As per the site condition) ---- etc.,complete with all leadNo357540.0357540.02.0FalseNoneNoneFalseNoneFalse715080.00
293222996731None018Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23Plus or minus 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with greater than75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger. The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods. The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. 1,000 CFM / 40 mm TSP / 0.75 kW ---- etc.,complete with all leadNo41300.041300.02.0FalseNoneNoneFalseNoneFalse82600.00
293223096731None019Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23Plus or minus 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with greater than75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger. The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods. The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. 1,500 CFM / 40 mm TSP / 0.75 kW ---- etc.,complete with all leadNo61950.061950.02.0FalseNoneNoneFalseNoneFalse123900.00
293223196731None020Supply, Installation, Testing & Commissioning of Rectangular inline fan with variable speed regulator & Timer controle with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply. Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance. Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts. 200 CFM / 20mm TSP. ---- etc.,complete with all leadNo17700.017700.04.0FalseNoneNoneFalseNoneFalse70800.00
293223296731None021Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 1/4" (6.35 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc.,complete with all leadm1475.01475.0225.0FalseNoneNoneFalseNoneFalse331875.00
293223396731None022Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 3/8" (9.52 mm) X 21 Swg (0.8mm) - Soft drawn (Insulation = 13mm thick) ---- etc.,complete with all leadm1534.01534.050.0FalseNoneNoneFalseNoneFalse76700.00
293223496731None023Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 1/2" (12.7 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc.,complete with all leadm1711.01711.0225.0FalseNoneNoneFalseNoneFalse384975.00
293223596731None024Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 5/8" (15.9 mm) X 19 Swg (1 mm) - Soft drawn (Insulation = 13mm thick) ---- etc.,complete with all leadm18880.018880.050.0FalseNoneNoneFalseNoneFalse944000.00
293223696731None025Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 7/8" ( 22.2 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc.,complete with all leadm2124.02124.010.0FalseNoneNoneFalseNoneFalse21240.00
293223796731None026Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition. b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only. 1 1/8" (28.6 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc.,complete with all leadm2301.02301.020.0FalseNoneNoneFalseNoneFalse46020.00
293223896731None027Supply, Installation, Testing & Commissioning of Open cell "Class-1" Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL-181 and E2180 , Density 140-180Kg / m3, UL94 approved (HBF, HF 1 & HF 2) in accordance to UL 94,1996. Thermal conductivity 0.047 W / MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 1071-05 (section 12.7).  Moisture resistant-joining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier. Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement) Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer. 15mm Thick ---- etc.,complete with all leadSqm1416.01416.070.0FalseNoneNoneFalseNoneFalse99120.00
293223996731None028Supply, Installation, Testing & Commissioning of Factory fabricated powder coated Double skin plenum. Outer skin constructed with not less than 0.63mm thick GI sheet and the inner sheet shall be of not less than 0.63mm GI plain sheet., with 25mm thick sandwiched RPUF (CFC free) insulation of density not less than 40kg/cum. And with necessary High grade Extruded Aluminum cross supports for rigidity and cutouts for duct & AHU connections. Note: a) The Plenum shall be provided with as Access Door. (Size are not less then 800mmx600mm) b) These plenum is inside the AHU Rooms should be supported with special acoustic hangers to avoid transmission of vibaration from AHU Room to adjacent sensitive areas. c) Color of the Plenum should match the color of AHU & CSU installed at site. ---- etc.,complete with all leadSqm6490.06490.015.0FalseNoneNoneFalseNoneFalse97350.00
293224096731None029Supply, Installation, Testing & Commissioning of Fire damper with opposed blade (Fusible link type). Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link & spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C. (Area calculation : (L x B) ---- etc.,complete with all leadSqm15340.015340.02.0FalseNoneNoneFalseNoneFalse30680.00
293224196731None030Supply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc., (Area calculation : (L x B) ---- etc.,complete with all leadSqm10030.010030.02.0FalseNoneNoneFalseNoneFalse20060.00
293224296731None031Supply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications. (Area calculation : (L x B) ---- etc.,complete with all leadSqm11210.011210.02.0FalseNoneNoneFalseNoneFalse22420.00
293224396731None032Supply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange. 250 dia ---- etc.,complete with all leadNo2950.02950.030.0FalseNoneNoneFalseNoneFalse88500.00
293224496731None033Supply, Installation, Testing & Commissioning of Extruded Aluminum powder coated Exhaust air Disc valves/grille without volume control dampers for Pantry. a) Note: Colour shall be as per the False ceiling or Architect intent. 150 mm Dia ---- etc.,complete with all leadNo1770.01770.010.0FalseNoneNoneFalseNoneFalse17700.00
293224596731None034Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges. Note: Colour shall be as per the False ceiling or Architect intent. ---- etc.,complete with all leadSqm10620.010620.02.0FalseNoneNoneFalseNoneFalse21240.00
293224696731None035Supply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers. (Used in supplay air) ---- etc.,complete with all leadSqm7670.07670.02.0FalseNoneNoneFalseNoneFalse15340.00
293224796731None036Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. 40 mm dia ---- etc.,complete with all leadm649.0649.020.0FalseNoneNoneFalseNoneFalse12980.00
293224896731None037Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. 32 mm dia ---- etc.,complete with all leadm531.0531.040.0FalseNoneNoneFalseNoneFalse21240.00
293224996731None038Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. 25 mm dia ---- etc.,complete with all leadm413.0413.0100.0FalseNoneNoneFalseNoneFalse41300.00
293225096731None039Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units. Mini Blanc Pumps (External) for Hi-Wall units. (Max. flow 12L/h & Head is 10Met) ---- etc.,complete with all leadNo10620.010620.08.0FalseNoneNoneFalseNoneFalse84960.00
293225196731None040Mini Tank Pump (Less then 5.0 TR CSU/FCU) - (Max. flow 35L/h & Head is 15Met) ---- etc.,complete with all leadNo14160.014160.03.0FalseNoneNoneFalseNoneFalse42480.00
293225296731None041Max Hi-Flow (Above 5.0 TR CSU/FCU) - (Max. flow 550L/h & Head is 5Met) ---- etc.,complete with all leadNo17700.017700.01.0FalseNoneNoneFalseNoneFalse17700.00
293225396731None042Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp) Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank. 1.5 Kw ---- etc.,complete with all leadNo8850.08850.03.0FalseNoneNoneFalseNoneFalse26550.00
293225496731None043Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp) Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank. 3.0 Kw ---- etc.,complete with all leadNo12980.012980.03.0FalseNoneNoneFalseNoneFalse38940.00
293225596731None044Supply, Installation, Testing & Commissioning of Magnehelic Differential Pressure Gages (IP-67 enclosure) to Indicate Positive, Negative or Differential, Accurate within 1%. Note: Pressures must be less than 35 psi.Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations. Costing is inclusive of with necessary fittings and Pitot Tube and etc.. AHU/CSU Filter Section ---- etc.,complete with all leadNo11210.011210.02.0FalseNoneNoneFalseNoneFalse22420.00
293225696731None045Supply, Installation, Testing & Commissioning of Duct Type Temperature & RH Sensors (IP-40 enclosure) (Immersion depth : 230 mm) with all mounting accessories to measure the Return Air temperatures. (Temperature range : -0 DegreeC to 55 DegreeC & R.H. range 10% to 90%) Note : Used for AHU's, CSU's FCU's & Cassette units. ---- etc.,complete with all leadNo10030.010030.02.0FalseNoneNoneFalseNoneFalse20060.00
293225796731None046Supply, Installation, Testing & Commissioning of Room Type Temperature & RH Digital Sensors (Thermostats) with all mounting accessories to measure the critical Room air temperatures. (Temperature range : -20 DegreeC to 60 DegreeC & R.H. range 0% to 99%) ---- etc.,complete with all leadNo10030.010030.02.0FalseNoneNoneFalseNoneFalse20060.00
293225896731None047Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units. Note : a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval. b) Electrical Power cabling quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity. c) Actual measurement of Electrical Power cabling quantity (Rmt) should be taken as per site condition only. 3.0 Core x 2.5 Sqmm - For AHU/CSU/Ventilation units units. (Can be used up to 3.7 Kw / 3Phase) Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc.,complete with all leadm531.0531.0110.0FalseNoneNoneFalseNoneFalse58410.00
17097048020000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(Plumbing work-Internal water supply & sanitary works, External Water supply & Drainage Works)2079263.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293225996732NoneV-2 Pg No 125 Itm No 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 40mm dia pipes, From wash basin waste lines-GF Toilet ---- etc.,complete with all leadm376.65376.6570.0FalseNoneNoneFalseNoneFalse26365.50
293226096732NoneV-2 Pg No 125 Itm No 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 50mm dia pipes, From sink & urinal waste lines-GF Toilet ---- etc.,complete with all leadm478.25478.2520.0FalseNoneNoneFalseNoneFalse9565.00
293226196732NoneV-2 Pg No 128 Itm No 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage). 75mm nominal dia pipes.GF Toilet ---- etc.,complete with all leadm358.07358.07135.0FalseNoneNoneFalseNoneFalse48339.450
293226296732NoneV-2 Pg No 128 Itm No 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage). 110mm nominal dia pipes.GF Toilet ---- etc.,complete with all leadm477.01477.01120.0FalseNoneNoneFalseNoneFalse57241.20
293226396732NoneV-2 Pg No 125 Itm No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter-GF Toilet ---- etc.,complete with all leadm244.08244.0820.0FalseNoneNoneFalseNoneFalse4881.60
293226496732NoneV-2 Pg No 125 Itm No 13.49Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.GF Toilet ---- etc.,complete with all leadm703.75703.7550.0FalseNoneNoneFalseNoneFalse35187.50
293226596732NoneV-2 Pg No 128 Itm No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete-GF Toilet ---- etc.,complete with all leadEach302.31302.3120.0FalseNoneNoneFalseNoneFalse6046.20
293226696732NoneV-2 Pg No 123 Itm No 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. GF Toilet ---- etc.,complete with all leadEach387.8387.826.0FalseNoneNoneFalseNoneFalse10082.80
293226796732NoneV-2 Pg No 136 Itm No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.GF Toilet ---- etc.,complete with all leadEach1511.581511.5812.0FalseNoneNoneFalseNoneFalse18138.960
293226896732NoneV-2 Pg No 119 Itm No 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931-GF Toilet ---- etc.,complete with all leadEach768.18768.1824.0FalseNoneNoneFalseNoneFalse18436.320
293226996732NoneV-2 Pg No 131 Itm No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid-GF Toilet ---- etc.,complete with all leadEach5994.285994.288.0FalseNoneNoneFalseNoneFalse47954.240
293227096732NoneV-2 Pg No 131 Itm No 14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern-GF Toilet ---- etc.,complete with all leadEach5518.55518.51.0FalseNoneNoneFalseNoneFalse5518.50
293227196732NoneV-2 Pg No 132 Itm No 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps-GF Toilet ---- etc.,complete with all leadEach3818.593818.5911.0FalseNoneNoneFalseNoneFalse42004.490
293227296732NoneV-2 Pg No 137 Itm No 14.37.1Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc.,complete with all leadEach379.13379.1314.0FalseNoneNoneFalseNoneFalse5307.820
293227396732NoneV-2 Pg No A-41 Itm No 978Providing and fixing Unplasticised P.V.C.connection pipe with brass union 30 cm long 15 mm bore-GF Toilet ---- etc.,complete with all leadEach47.0847.0816.0FalseNoneNoneFalseNoneFalse753.280
293227496732NoneV-2 Pg No 137 Itm No 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g-GF Toilet ---- etc.,complete with all leadEach111.51111.5114.0FalseNoneNoneFalseNoneFalse1561.140
293227596732NoneV-2 Pg No 118 Itm No 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter-GF Toilet ---- etc.,complete with all leadEach345.68345.681.0FalseNoneNoneFalseNoneFalse345.680
293227696732NoneV-2 Pg No A-37 Itm No 851Providing & fixing SS Side operated Single lever wall mixer with L shaped Tubular bend set for overhead shower - Economy-GF Toilet ---- etc.,complete with all leadEach3840.93840.91.0FalseNoneNoneFalseNoneFalse3840.90
293227796732NoneV-2 Pg No 134 Itm No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm-GF Toilet ---- etc.,complete with all leadEach6296.66296.64.0FalseNoneNoneFalseNoneFalse25186.40
293227896732NoneV-2 Pg No 122 Itm No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. GROUND FLOOR- 15 mm nominal dia Pipes ---- etc.,complete with all leadm382.85382.85120.0FalseNoneNoneFalseNoneFalse45942.00
293227996732NoneV2 Pg No 122 Itm No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. GROUND FLOOR- 20 mm nominal dia Pipes ---- etc.,complete with all leadm469.58469.5850.0FalseNoneNoneFalseNoneFalse23479.00
293228096732NoneV2 Pg No 122 Itm No 13.33.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-Shafts & Terrace. 20 mm nominal dia Pipes ---- etc.,complete with all leadm268.86268.86155.0FalseNoneNoneFalseNoneFalse41673.30
293228196732NoneV2 Pg No 122 Itm No 13.33.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-Shafts & Terrace. 25 mm nominal dia Pipes ---- etc.,complete with all leadm366.74366.74160.0FalseNoneNoneFalseNoneFalse58678.40
293228296732NoneV-2 Pg No 115 Itm No 13.5.2Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore ---- etc.,complete with all leadNo389.05389.058.0FalseNoneNoneFalseNoneFalse3112.40
293228396732NoneV-2 Pg No 115 Itm No 13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore ---- etc.,complete with all leadNo411.35411.359.0FalseNoneNoneFalseNoneFalse3702.150
293228496732NoneV-6 Pg No 34 Itm No 7.3.3Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding.300 L ---- etc.,complete with all leadEach86712.6586712.653.0FalseNoneNoneFalseNoneFalse260137.950
293228596732NoneV-2 Pg No 125 Itm No 13.50.5Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 40mm dia pipes, From wash basin waste lines-FF Toilet ---- etc.,complete with all leadm380.42380.4230.0FalseNoneNoneFalseNoneFalse11412.60
293228696732NoneV-2 Pg No 125 Itm No 13.50.6Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. 50mm dia pipes, From sink & urinal waste lines-FF Toilet ---- etc.,complete with all leadm483.03483.0310.0FalseNoneNoneFalseNoneFalse4830.30
293228796732NoneV-2 Pg No 128 Itm No 13.64.1Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-FF Toilet. 75mm nominal dia pipes ---- etc.,complete with all leadm361.65361.6530.0FalseNoneNoneFalseNoneFalse10849.50
293228896732NoneV-2 Pg No 128 Itm No 13.64.2Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-FF Toilet. 110mm nominal dia pipes ---- etc.,complete with all leadm481.78481.7825.0FalseNoneNoneFalseNoneFalse12044.50
293228996732NoneV-2 Pg No 125 Itm No 13.47Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter-FF Toilet ---- etc.,complete with all leadm246.52246.5220.0FalseNoneNoneFalseNoneFalse4930.40
293229096732NoneV-2 Pg No 128 Itm No 13.63Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete-FF Toilet ---- etc.,complete with all leadEach305.33305.3312.0FalseNoneNoneFalseNoneFalse3663.960
293229196732NoneV-2 Pg No 123 Itm No 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.FF Toilet ---- etc.,complete with all leadEach391.68391.6820.0FalseNoneNoneFalseNoneFalse7833.60
293229296732NoneV-2 Pg No 136 Itm No 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.FF Toilet ---- etc.,complete with all leadEach1526.691526.6910.0FalseNoneNoneFalseNoneFalse15266.90
293229396732NoneV-2 Pg No 119 Itm No 13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931-FF Toilet ---- etc.,complete with all leadEach775.86775.8621.0FalseNoneNoneFalseNoneFalse16293.060
293229496732NoneV-2 Pg No 131 Itm No 14.2.1Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.FF Toilet ---- etc.,complete with all leadEach6054.226054.226.0FalseNoneNoneFalseNoneFalse36325.320
293229596732NoneV-2 Pg No 131 Itm No 14.4.1Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern.FF Toilet ---- etc.,complete with all leadEach5573.695573.691.0FalseNoneNoneFalseNoneFalse5573.690
293229696732NoneV-2 Pg No 132 Itm No 14.7.1Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps.FF Toilet ---- etc.,complete with all leadEach3856.783856.788.0FalseNoneNoneFalseNoneFalse30854.240
293229796732NoneV-2 Pg No 137 Itm No 14.37.1Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g.FF Toilet ---- etc.,complete with all leadEach382.92382.929.0FalseNoneNoneFalseNoneFalse3446.280
293229896732NoneV-2 Pg No A-41 Itm No 978Providing and fixing Unplasticised P.V.C.connection pipe with brass union 30 cm long 15 mm bore.FF Toilet ---- etc.,complete with all leadEach47.5547.5513.0FalseNoneNoneFalseNoneFalse618.150
293229996732NoneV-2 Pg No 137 Itm No 14.36.1Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g.FF Toilet ---- etc.,complete with all leadEach112.62112.629.0FalseNoneNoneFalseNoneFalse1013.580
293230096732NoneV-2 Pg No 118 Itm No 13.9.2Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter. FF Toilet ---- etc.,complete with all leadEach349.13349.132.0FalseNoneNoneFalseNoneFalse698.260
293230196732NoneV2 Pg No 135 Itm No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. FF Toilet ---- etc.,complete with all leadEach2992.072992.072.0FalseNoneNoneFalseNoneFalse5984.140
293230296732NoneV-2 Pg No 134 Itm No 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm. FF Toilet ---- etc.,complete with all leadEach6359.566359.563.0FalseNoneNoneFalseNoneFalse19078.680
293230396732NoneV-2 Pg No 122 Itm No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. FIRST FLOOR- 15 mm nominal dia Pipes ---- etc.,complete with all leadm386.67386.6785.0FalseNoneNoneFalseNoneFalse32866.950
293230496732NoneV2 Pg No 122 Itm No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. FIRST FLOOR- 20 mm nominal dia Pipes ---- etc.,complete with all leadm474.27474.2740.0FalseNoneNoneFalseNoneFalse18970.80
293230596732None049Air Vent Cowel-75mm ---- etc.,complete with all leadNo413.0413.08.0FalseNoneNoneFalseNoneFalse3304.00
293230696732None050Air Vent Cowel-110mm ---- etc.,complete with all leadNo590.0590.07.0FalseNoneNoneFalseNoneFalse4130.00
293230796732None051Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ). ---- etc.,complete with all leadNo2183.02183.014.0FalseNoneNoneFalseNoneFalse30562.00
293230896732NoneV-1 Pg No 6 Itm No 1.4.1Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m ---- etc.,complete with all leadCum299.83299.83315.0FalseNoneNoneFalseNoneFalse94446.450
293230996732NoneV-1 Pg No 7 Itm No 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications ---- etc.,complete with all leadCum198.24198.24157.5FalseNoneNoneFalseNoneFalse31222.80
293231096732NoneV-5 Pg No 114 Itm No 10.3.7Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: Pipes of SN8 Self Fit - 160mm dia. ---- etc.,complete with all leadm764.46764.46110.0FalseNoneNoneFalseNoneFalse84090.60
293231196732NoneV-5 Pg No 115 Itm No 10.3.8Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: Pipes of SN8 Self Fit - 200mm dia. ---- etc.,complete with all leadm1102.711102.7180.0FalseNoneNoneFalseNoneFalse88216.80
293231296732NoneV-5 Pg No 114 Itm No 10.3.9Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: Pipes of SN8 Self Fit - 250mm dia. ---- etc.,complete with all leadm1694.951694.9550.0FalseNoneNoneFalseNoneFalse84747.50
293231396732NoneV-5 Pg No 113 Itm No 10.2.4Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN4, 160mm dia. ---- etc.,complete with all leadm713.66713.66115.0FalseNoneNoneFalseNoneFalse82070.90
293231496732NoneV-5 Pg No 191 Itm No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc.,complete with all leadEach6757.56757.510.0FalseNoneNoneFalseNoneFalse67575.00
293231596732NoneV-2 Pg No 123 Itm No 13.38Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: ---- etc.,complete with all leadNo3137.143137.147.0FalseNoneNoneFalseNoneFalse21959.980
293231696732NoneV-5 Pg No 194 Itm No 16.18.6Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole: Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,3.0M depth & SFRC cover & frame ---- etc.,complete with all leadNo97246.6397246.631.0FalseNoneNoneFalseNoneFalse97246.630
293231796732NoneV-2 Pg No 118 Itm No 13.23.5Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 50 mm nominal bore, 242mm long, weighing not less than 1240 g ---- etc.,complete with all leadNo1665.211665.213.0FalseNoneNoneFalseNoneFalse4995.630
293231896732NoneV5 Pg No 86 Itm No 7.5.1Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 80mm dia. ---- etc.,complete with all leadEach1957.621957.628.0FalseNoneNoneFalseNoneFalse15660.960
293231996732NoneV5 Pg No 86 Itm No 7.5.2Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 100mm dia. ---- etc.,complete with all leadEach2305.772305.776.0FalseNoneNoneFalseNoneFalse13834.620
293232096732NoneV5 Pg No 86 Itm No 7.5.3Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 150mm dia. ---- etc.,complete with all leadEach2935.192935.194.0FalseNoneNoneFalseNoneFalse11740.760
293232196732NoneV5 Pg No 86 Itm No 7.5.5Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete . For DI/CI puddle flanges of 250mm dia. ---- etc.,complete with all leadEach5587.895587.893.0FalseNoneNoneFalseNoneFalse16763.670
293232296732NoneV5 Pg No 157 Itm No 13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (pump room collection sump pumps) (2 HP, Size 65x50 Head 13M, Discharge 462 LPM) ---- etc.,complete with all leadNo19340.7919340.792.0FalseNoneNoneFalseNoneFalse38681.580
293232396732NoneV5 Pg No 156 Itm No 13.32Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc.,complete with all leadNo8053.58053.58.0FalseNoneNoneFalseNoneFalse64428.00
293232496732NoneV5 Pg No 157 Itm No 13.40.3Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (Raw water pumps) (3 HP, size 50x40 Head 30M, Discharge 198 LPM) ---- etc.,complete with all leadNo23313.0223313.022.0FalseNoneNoneFalseNoneFalse46626.040
293232596732NoneV5 Pg No 157 Itm No 13.40.5Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. Sump To OHT (DOMESTIC)/(FLUSHING) (Hospital) ( 5 HP, size 50x40 Head 46M, Discharge 174 LPM) ---- etc.,complete with all leadNo32730.6632730.664.0FalseNoneNoneFalseNoneFalse130922.640
17097048020000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(MGPLS)5319746.8
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293232696733None001Oxygen Manifold System Main : The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. 4+4 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. Semi automatic control panel. Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Oxygen System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc.,complete with all leadSet179124.0179124.01.0FalseNoneNoneFalseNoneFalse179124.00
293232796733None002Oxygen Manifold System : Emergency Supply, Installation, Testing and commissioning of 2 cylinder (1 + 1)Oxygen Cylinders Manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc.,complete with all leadSet47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
293232896733None003Nitrous Oxide Main Manifold System Supply, Installation, Testing and commissioning of 2 cylinder (1 + 1) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Semi Automatic Nitrous Oxide Main Manifold Control Panel Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc.,complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
293232996733None004Nitrous Oxide Emergency Manifold System Supply, Installation, Testing and commissioning of 1 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc.,complete with all leadSet47200.047200.01.0FalseNoneNoneFalseNoneFalse47200.00
293233096733None005Compressed Air System: System For Medical use. Type : Reciprocating, Air cooled oil grease free Capacity of Piston Displacement : 22.93 cfm 649 Lpm Drive : Belt driven No. of Air Compressors : 2 Nos. (1W + 1S by) Motor Capacity : 5 HP as required Receiver Capacity : 1000 liters water capacity Air reciever Receiver type : Vertical type with inlet, outlet & drain provisions ---- etc.,complete with all leadSet800630.0800630.01.0FalseNoneNoneFalseNoneFalse800630.00
293233196733None006Duplex Medical Air Dryer System ( Breathing Air System) 40 CFM Air Dryer Min Working Pressure should be 4 bar, Rated Inlet Pressure should be 7 bar Max Working Pressure should be 16 bar Supply Voltage Should be 100-240 VAC, 50/60 Hz, 1 Ph Rated Inlet temperature should be 38 deg C Dryer capable to give should be 40 PDP Purge Loss 15% Air quality As per NFPA 99 Dual System Three stage filter (Dessicated drier) CO & Dew point level as per NFPA 99 Bacterial Penetration 0.00001% Failure Indication Purge Saving control - Manual No refrigerant used Energy saving - Dew point based dryer cycling ---- etc.,complete with all leadNo88205.088205.01.0FalseNoneNoneFalseNoneFalse88205.00
293233296733None007COMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGE The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch - I Standard. Total 3-stages of filters Shouldbe used as mentioned below: Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. Stage 2: Oil aerosol contents removal up to 0.01 mg/cum. Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. ---- etc.,complete with all leadSet67850.067850.01.0FalseNoneNoneFalseNoneFalse67850.00
293233396733None008Air Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz ---- etc.,complete with all leadNo81420.081420.01.0FalseNoneNoneFalseNoneFalse81420.00
293233496733None009VACCUM SUPPLY SYSTEM COMPLETE IN ALL RESPECT (with receiver tank):The pump installation shall be duplex system consisting of two (1W+1S BY) Identical Rotary Vane Pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 3276 LPM (200m3/h) i.e., 117 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa). The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system. Pump should be of reputed make as per international standards. The control panel shall consist of three separate Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 1500 Liter or as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust protection. The System should provide audible and visual local and remote alarm indications for the compressor temperature malfunction and reserve compressor in use. All control and alarm functions should remain energized while any compressor remains electrically on-line.  The System should provide manual reset for thermal malfunction shutdown. The lag Pumps should be able to start automatically if the lead compressor fails to operate. ---- etc.,complete with all leadSet949900.0949900.01.0FalseNoneNoneFalseNoneFalse949900.00
293233596733None010VACUUM BACTERIAL FILTERATION, Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere.These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below, FAC AT Atmospheric : 1850 LPM Size : G 1.5 Bacterial Removal : 0.0001% penetration when tested to BS: 3928 ---- etc.,complete with all leadSet162840.0162840.01.0FalseNoneNoneFalseNoneFalse162840.00
293233696733None011Copper Pipes : Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 35mm. ODx1.2 mm.thick. ---- etc.,complete with all leadm2570.042570.0470.0FalseNoneNoneFalseNoneFalse179902.80
293233796733None012Copper Pipes : Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 28mm. ODx0.9 mm.thick. ---- etc.,complete with all leadm1492.71492.7230.0FalseNoneNoneFalseNoneFalse343321.00
293233896733None013Copper Pipes : Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 22mm. ODx0.9 mm.thick. ---- etc.,complete with all leadm1156.41156.4300.0FalseNoneNoneFalseNoneFalse346920.00
293233996733None014Copper Pipes : Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 15mm. ODx0.9 mm.thick. ---- etc.,complete with all leadm949.9949.9450.0FalseNoneNoneFalseNoneFalse427455.00
293234096733None015Copper Pipes : Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections. Copper Pipe 12mm. ODx0.7 mm.thick. ---- etc.,complete with all leadm651.36651.36100.0FalseNoneNoneFalseNoneFalse65136.00
293234196733None016OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)- Oxygen Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc.,complete with all leadNo3392.53392.516.0FalseNoneNoneFalseNoneFalse54280.00
293234296733None017OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)- Vacuum Terminal - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc.,complete with all leadNo3392.53392.512.0FalseNoneNoneFalseNoneFalse40710.00
293234396733None018OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)- Compressed Air Terminals 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc.,complete with all leadNo3392.53392.59.0FalseNoneNoneFalseNoneFalse30532.50
293234496733None019OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)- Compressed Air Terminals 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc.,complete with all leadNo3392.53392.53.0FalseNoneNoneFalseNoneFalse10177.50
293234596733None020OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)- Nitous Oxide Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc.,complete with all leadNo3392.53392.53.0FalseNoneNoneFalseNoneFalse10177.50
293234696733None021ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES. Oxygen Flow meter with Humidifier Bottle:      Flow meter should be Backpressure Compensated.         Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute.       It should meet strict precision and durability standards.     Flow meter body should be made of brass material.     Flow tube and shroud components should be made of clear, impact resistant polycarbonate.        The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier should have built in safety valve. ---- etc.,complete with all leadNo2849.72849.79.0FalseNoneNoneFalseNoneFalse25647.30
293234796733None022Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps. ---- etc.,complete with all leadNo3528.23528.26.0FalseNoneNoneFalseNoneFalse21169.20
293234896733None023Theatre Vacuum Unit:    The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade.    Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either. - Left, Right or Both All the above items Should be mounted on a Trolley having a free moving castor wheels. ---- etc.,complete with all leadNo16962.516962.52.0FalseNoneNoneFalseNoneFalse33925.00
293234996733None024ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction- Isolation Valves 35 mm ---- etc.,complete with all leadNo5428.05428.05.0FalseNoneNoneFalseNoneFalse27140.00
293235096733None025ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction- Isolation Valves 28 mm ---- etc.,complete with all leadNo4071.04071.07.0FalseNoneNoneFalseNoneFalse28497.00
293235196733None026ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction- Isolation Valves 22 mm ---- etc.,complete with all leadNo3392.53392.58.0FalseNoneNoneFalseNoneFalse27140.00
293235296733None027ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction- Isolation Valves 15 mm ---- etc.,complete with all leadNo2714.02714.028.0FalseNoneNoneFalseNoneFalse75992.00
293235396733None028Zonal Valve box five Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position. The valve box door cannot be close during valve close position. ---- etc.,complete with all leadNo23364.023364.01.0FalseNoneNoneFalseNoneFalse23364.00
293235496733None029Digital Area Alarm for Five Gas Systems. Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc.,complete with all leadNo47495.047495.02.0FalseNoneNoneFalseNoneFalse94990.00
293235596733None030Bed Headed Panel and Railing. 1.5M Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets. Provision Medical Gas Terminal Units as follows.  2.1 Two oxygen outlet. 2.2  One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc.,complete with all leadNo36639.036639.04.0FalseNoneNoneFalseNoneFalse146556.00
293235696733None031Surgeon Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm. Loading capacity: 70-150kg. Level degrees rotation:less than340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos, Air 4 Bar 01 nos, Air 7 Bar 01 nos, Nitrous Oxide01 nos, Power socket 08 nos, Grounding terminal 01 nos, Platform 03 nos, IV pole 01 nos, Drawer 01 nos. ---- etc.,complete with all leadNo264615.0264615.01.0FalseNoneNoneFalseNoneFalse264615.00
293235796733None032Anaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation:less than340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc.,complete with all leadNo264615.0264615.02.0FalseNoneNoneFalseNoneFalse529230.00
17097048020000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(Fire Fighting work)10630183.7
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293235896734NoneV-6 Pg No 88 Itm No 15.83.1Supplying, Installing, testing and commissioning approved make Centrifugal pump end suction type couple to Electric motor of suitable Hp, fitted on a common base frame and rated for Fire duty. The quoted price shall aslso include 2 nos. Pressure guages fitted on suction & delivery side of the pump. The pumps shall run on 400/440V, 3 ph, 50Hz electric supply. Duty of pums: 1620 Lpm @ 70.0m Head.Control panel shall be per specification stated in Item No.87. including cost of materials, labour, usage charges of machinery complete as per specifications. (Cost of control pannel is not included) ---- etc.,complete with all leadNo291165.0291165.01.0FalseNoneNoneFalseNoneFalse291165.00
293235996734NoneV-6 Pg No 88 Itm No 15.84.2Supplying, Installing testing and commissioning of fire hydrant multi stage pump capable of delivering 1620 Lpm@ 70.0m head coupled to water coiled diesel enginer of adequate. HP It shall be fitted with a radiator on a common base frame with complete ancillary units such as coiling sytem, non return vialve, Y strainer, fuel tank of adequante capactiy, Pressure guage, pressure switch etc. complete Control panel shall be per specification stated in Item No.87. including cost of materials, labour, usage charges of machinery complete as per specifications. (Cost of control pannel is not included) ---- etc.,complete with all leadNo607110.0607110.01.0FalseNoneNoneFalseNoneFalse607110.00
293236096734NoneV-6 Pg No 88 Itm No 15.85Supplying, Installing testing & commissioning electrically driven jockey pump of capacity 180.0 Lmpm at 75.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V AC supply including foundation bolt etc. complete. Control panel shall be as per item No.87, including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc.,complete with all leadNo105315.0105315.01.0FalseNoneNoneFalseNoneFalse105315.00
293236196734NoneV-6 Pg No 97 Itm No 15.139Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Jockey pump 25HP ---- etc.,complete with all leadUnit344442.0344442.01.0FalseNoneNoneFalseNoneFalse344442.00
293236296734NoneV-6 Pg No 94 Itm No 15.127.2Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 150mm dia ---- etc.,complete with all leadNo15487.515487.59.0FalseNoneNoneFalseNoneFalse139387.50
293236396734NoneV-6 Pg No 94 Itm No 15.127.3Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-incharge of the work 100mm dia CI butterfly valves ---- etc.,complete with all leadNo11151.011151.07.0FalseNoneNoneFalseNoneFalse78057.00
293236496734NoneV-6 Pg No 94 Itm No 15.127.4Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 80mm dia ---- etc.,complete with all leadNo8673.08673.02.0FalseNoneNoneFalseNoneFalse17346.00
293236596734NoneV-6 Pg No 95 Itm No 15.128.2Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150 mm dia ---- etc.,complete with all leadNo14248.514248.56.0FalseNoneNoneFalseNoneFalse85491.00
293236696734NoneV-6 Pg No 95 Itm No 15.128.3Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia ---- etc.,complete with all leadNo8821.688821.682.0FalseNoneNoneFalseNoneFalse17643.360
293236796734NoneV-6 Pg No 95 Itm No 15.128.4Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80 mm dia ---- etc.,complete with all leadNo6814.56814.52.0FalseNoneNoneFalseNoneFalse13629.00
293236896734NoneV-6 Pg No 95 Itm No 15.129.1Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.200mm dia ---- etc.,complete with all leadNo30355.530355.53.0FalseNoneNoneFalseNoneFalse91066.50
293236996734NoneV-6 Pg No 95 Itm No 15.129.3Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia ---- etc.,complete with all leadNo15351.2115351.211.0FalseNoneNoneFalseNoneFalse15351.210
293237096734NoneV-6 Pg No 96 Itm No 15.136Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. ---- etc.,complete with all leadNo37170.037170.01.0FalseNoneNoneFalseNoneFalse37170.00
293237196734NoneV-6 Pg No 96 Itm No 15.132Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. ---- etc.,complete with all leadNo3593.13593.13.0FalseNoneNoneFalseNoneFalse10779.30
293237296734NoneV-6 Pg No 95 Itm No 15.131Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. ---- etc.,complete with all leadNo2416.052416.056.0FalseNoneNoneFalseNoneFalse14496.30
293237396734NoneV-2 Pg No 82 Itm No 11.16.2Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc.,complete with all leadKg182.13182.131100.0FalseNoneNoneFalseNoneFalse200343.00
293237496734NoneBSR 21-22 Page No Item No 32.14FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc.,complete with all leadKm636895.56636895.560.18FalseNoneNoneFalseNoneFalse114641.20080
293237596734NoneBSR 21-22 Page No Item No 32.05FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 4.0 Core 16.00 Sq.mm.Main Panel to Jockey ---- etc.,complete with all leadKm227284.63227284.630.2FalseNoneNoneFalseNoneFalse45456.9260
293237696734None01912 Core x 2.5Sqmm For Main Panel to DG ---- etc.,complete with all leadm684.4684.450.0FalseNoneNoneFalseNoneFalse34220.00
293237796734NoneCSR SR 21-22 Page No 3 Item No 1.17.33 Core x 1.5Sqmm for Pressure Switch ---- etc.,complete with all leadm117.7117.770.0FalseNoneNoneFalseNoneFalse8239.00
293237896734NoneV-6 Pg No 38 Itm No 9.4.6Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type.150 AH capacity ---- etc.,complete with all leadNo34923.6934923.691.0FalseNoneNoneFalseNoneFalse34923.690
293237996734NoneCSR 21-22 Page No 18 Item No 4.1.4Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. ---- etc.,complete with all leadm962.7962.7100.0FalseNoneNoneFalseNoneFalse96270.00
293238096734NoneV-6 Pg No 54 Itm No 12.58.2GI/Copper strips for grounding connections, using necessary fixing materials as required. (25 x 3 mm GI strip) ---- etc.,complete with all leadm101.59101.59150.0FalseNoneNoneFalseNoneFalse15238.50
293238196734NoneV-6 Pg No 89 Itm No 15.86Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc.,complete with all leadEach1858.51858.53.0FalseNoneNoneFalseNoneFalse5575.50
293238296734NoneV-6 Pg No 94 Itm No 15.125SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc.,complete with all leadNo1486.81486.810.0FalseNoneNoneFalseNoneFalse14868.00
293238396734NoneV-6 Pg No 94 Itm No 15.126SITC of Gun metal BALL VALVE SIZE OF 19/20 mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc.,complete with all leadNo1177.051177.058.0FalseNoneNoneFalseNoneFalse9416.40
293238496734NoneV-6 Pg No 91 Itm No 15.97.3Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 150 mm dia ---- etc.,complete with all leadm4832.14832.1350.0FalseNoneNoneFalseNoneFalse1691235.00
293238596734NoneV-6 Pg No 91 Itm No 15.97.4Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 100 mm dia ---- etc.,complete with all leadm3531.153531.15300.0FalseNoneNoneFalseNoneFalse1059345.00
293238696734NoneV-6 Pg No 91 Itm No 15.97.5Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 80 mm dia ---- etc.,complete with all leadm2849.72849.7200.0FalseNoneNoneFalseNoneFalse569940.00
293238796734NoneV-6 Pg No 91 Itm No 15.97.6Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 65 mm dia ---- etc.,complete with all leadm2106.32106.3100.0FalseNoneNoneFalseNoneFalse210630.00
293238896734NoneV-6 Pg No 91 Itm No 15.97.7Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 50 mm dia ---- etc.,complete with all leadm1610.71610.7150.0FalseNoneNoneFalseNoneFalse241605.00
293238996734NoneV-6 Pg No 91 Itm No 15.97.8Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 40 mm dia ---- etc.,complete with all leadm1300.951300.95120.0FalseNoneNoneFalseNoneFalse156114.00
293239096734NoneV-6 Pg No 91 Itm No 15.97.9Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 32 mm dia ---- etc.,complete with all leadm991.2991.2150.0FalseNoneNoneFalseNoneFalse148680.00
293239196734NoneV-6 Pg No 91 Itm No 15.97.10Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 25 mm dia ---- etc.,complete with all leadm867.3867.3500.0FalseNoneNoneFalseNoneFalse433650.00
293239296734NoneV-6 Pg No 91 Itm No 15.98.2Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia ---- etc.,complete with all leadm495.6495.6300.0FalseNoneNoneFalseNoneFalse148680.00
293239396734NoneV-6 Pg No 91 Itm No 15.98.3Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia ---- etc.,complete with all leadm309.75309.75100.0FalseNoneNoneFalseNoneFalse30975.00
293239496734NoneV-6 Pg No 94 Itm No 15.127.6Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc.,complete with all leadNo5575.55575.52.0FalseNoneNoneFalseNoneFalse11151.00
293239596734NoneCSR -21-22 Page No Item No 18.23.2Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.150mm dia ---- etc.,complete with all leadEach11177.0111177.012.0FalseNoneNoneFalseNoneFalse22354.020
293239696734NoneV-6 Pg No 90 Itm No 15.96.2Providing, fixing, testing & commissioning ofinstallation control valve of cast iron body,brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm andhydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150mm dia ---- etc.,complete with all leadEach86730.086730.01.0FalseNoneNoneFalseNoneFalse86730.00
293239796734NoneV-6 Pg No 94 Itm No 15.123Supplying Installing, testing and commissioning of 150mm dia 4 way Fire brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc.,complete with all leadNo47082.047082.01.0FalseNoneNoneFalseNoneFalse47082.00
293239896734NoneV-6 Pg No 94 Itm No 15.124Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc.,complete with all leadNo40887.040887.01.0FalseNoneNoneFalseNoneFalse40887.00
293239996734NoneV-6 Pg No 89 Itm No 15.86FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc.,complete with all leadNo13009.513009.52.0FalseNoneNoneFalseNoneFalse26019.00
293240096734NoneV-6 Pg No 89 Itm No 15.85Supplying Installing, testing and commissioning of63mm mm dia double headed Gun mental Hydrant Valve with flanged inlet 2Nos, stop valve, spindle and cast iron hand wheel. It has a 2 Nos female instantaneous outlet with blank cap and is hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm2 of pressure confirms to IS : 2190 with blank cap and wheel as per IS 5290 etc. including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc.,complete with all leadNo22921.522921.54.0FalseNoneNoneFalseNoneFalse91686.00
293240196734NoneV-6 Pg No 89 Itm No 15.88Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc.,complete with all leadEach6195.06195.012.0FalseNoneNoneFalseNoneFalse74340.00
293240296734NoneV-6 Pg No 89 Itm No 15.87Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc.,complete with all leadEach5575.55575.512.0FalseNoneNoneFalseNoneFalse66906.00
293240396734NoneV-6 Pg No 89 Itm No 15.89Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc.,complete with all leadEach8053.58053.512.0FalseNoneNoneFalseNoneFalse96642.00
293240496734NoneV-6 Pg No 89 Itm No 15.9Supplying Installing, testing and commissioning of Hose reel cabin ---- etc.,complete with all leadEach6318.96318.92.0FalseNoneNoneFalseNoneFalse12637.80
293240596734NoneV-6 Pg No 89 Itm No 15.91Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 Degree swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc.,complete with all leadEach6442.86442.82.0FalseNoneNoneFalseNoneFalse12885.60
293240696734NoneV-6 Pg No 123 Itm No 13.37Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc.,complete with all leadNo387.8387.820.0FalseNoneNoneFalseNoneFalse7756.00
293240796734NoneV-6 Pg No 90 Itm No 15.93Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/wall mounted type designed to operate 68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 DegreeCOrange, 68 DegreeC - Red, 79 DegreeC - Yellow, 93 DegreeC - Green, 141 DegreeC - Blue, 182 DegreeC Mauve, 227/260 DegreeC - Black) ---- etc.,complete with all leadEach464.62464.62200.0FalseNoneNoneFalseNoneFalse92924.00
293240896734NoneV-6 Pg No 94 Itm No 15.122Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. ---- etc.,complete with all leadEach3097.53097.530.0FalseNoneNoneFalseNoneFalse92925.00
293240996734NoneV-6 Pg No 94 Itm No 15.120.Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc.,complete with all leadEach136.29136.2930.0FalseNoneNoneFalseNoneFalse4088.70
293241096734NoneV-6 Pg No 100 Itm No 15.163Supply, erection, testing and commissioning of 1" GI/MS collar. ---- etc.,complete with all leads And lifts as per specifications and as directed by the Engineer-in-charge . ---- etc.,complete with all leadNo136.29136.29200.0FalseNoneNoneFalseNoneFalse27258.00
293241196734NoneV-6 Pg No 68 Itm No 15.22Supply and installation of 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg, empty weight 1.7 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,8,C and electrically started Fire, 8 Rating 218, Can construction: Deep drawn &Co., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete IS15683 and CE Approved. ---- etc.,complete with all leadNo8053.58053.53.0FalseNoneNoneFalseNoneFalse24160.50
293241296734NoneV-6 Pg No 72 Itm No 15.33CO2 2Kg Squeeze grip Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc.,complete with all leadEach6814.56814.55.0FalseNoneNoneFalseNoneFalse34072.50
293241396734NoneV-6 Pg No 72 Itm No 15.34Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc.,complete with all leadEach8053.58053.54.0FalseNoneNoneFalseNoneFalse32214.00
293241496734NoneV-6 Pg No 72 Itm No 15.33Providing Aqueous Film-Forming Foam - 9 Ltr Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc.,complete with all leadEach10035.910035.92.0FalseNoneNoneFalseNoneFalse20071.80
293241596734NoneV-6 Pg No 62 Itm No 15.4Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, ---- etc.,complete with all leadEach3531.153531.156.0FalseNoneNoneFalseNoneFalse21186.90
293241696734NoneV-6 Pg No 77 Itm No 15.49Supply and installation of 6 Ltr Watermist technology base, Stored pressure type, Rating -8A. 34B & 40F, Mild steel body t, Tamper- proof safety seal, Effective on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in pressure gauge, lnstalert, Uses distilled water, Gross Weight 12.15 Kg, empty Weight 6.15kg, can Height 615mm Diameter 175M M, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Can Construction: Deep drawn & C02 Mig welded, Valve Construction: Forgin & Machining, ERDA approved, Sheet metal thickness : 2.00MM, Discharge Time : Min. 64 Sec., 5 Year Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete ---- etc.,complete with all leadEach9540.39540.34.0FalseNoneNoneFalseNoneFalse38161.20
293241796734NoneV-6 Pg No 93 Itm No 15.112Supplying of two bucket stand alongwith buckets. complete ---- etc.,complete with all leadEach1362.91362.92.0FalseNoneNoneFalseNoneFalse2725.80
293241896734NonePWD SR -21-22 Page No 14 Item No 15.72Providing and fixing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm) (Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.) (signage with text FIRE EXIT,Size shall be 15cm x 60cm.) (route plan Fire Escape Route Plan A2 Size) ---- etc.,complete with all leadSq CM2.472.4724300.0FalseNoneNoneFalseNoneFalse60021.00
293241996734None062Providing and fixing in position the signages "FIRE ORDER" it should contain the following text on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'. A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN. E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. ---- etc.,complete with all leadEach3097.53097.54.0FalseNoneNoneFalseNoneFalse12390.00
293242096734None063ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM. A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor) C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor) F) FIRE FIGHTING AGENCY: PHONE : (Current phone numbers to be provided in this location by the contractor) FAX : (Current fax numbers to be provided in this location by the contractor) ---- etc.,complete with all leadEach3097.53097.54.0FalseNoneNoneFalseNoneFalse12390.00
293242196734None064Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work ---- etc.,complete with all leadNo58410.058410.01.0FalseNoneNoneFalseNoneFalse58410.00
293242296734NoneV-6 Pg No 92 Itm No 15.108.3Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 40 Zone cansole. Complete ---- etc.,complete with all leadNo100359.0100359.01.0FalseNoneNoneFalseNoneFalse100359.00
293242396734NoneV-6 Pg No 93 Itm No 15.109P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc.,complete with all leadNo43674.7543674.751.0FalseNoneNoneFalseNoneFalse43674.750
293242496734NoneV-6 Pg No 93 Itm No 15.110Supplying Installing, testing and commissioning of MIKE ---- etc.,complete with all leadEach6814.56814.51.0FalseNoneNoneFalseNoneFalse6814.50
293242596734NoneV-6 Pg No 92 Itm No 15.107Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc.,complete with all leadEach3035.553035.554.0FalseNoneNoneFalseNoneFalse12142.20
293242696734NoneV-6 Pg No 92 Itm No 15.105Supplying and drawing of 2 Core X 1.5 Sqmm copper conductor armoured cable ---- etc.,complete with all leadm185.85185.852710.0FalseNoneNoneFalseNoneFalse503653.50
293242796734NoneV-6 Pg No 84 Itm No 15.66.1Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. 2 Loop Panel ---- etc.,complete with all leadEach260190.0260190.02.0FalseNoneNoneFalseNoneFalse520380.00
293242896734None071Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc ---- etc.,complete with all leadEach560500.0560500.01.0FalseNoneNoneFalseNoneFalse560500.00
293242996734None072Supply, intallation, testing and Commissioning of Network card for fire alram panels integration ---- etc.,complete with all leadEach88500.088500.02.0FalseNoneNoneFalseNoneFalse177000.00
293243096734NoneV-6 Pg No Itm No 15.103Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications. ---- etc.,complete with all leadEach309.75309.7510.0FalseNoneNoneFalseNoneFalse3097.50
293243196734NoneV-6 Pg No 84 Itm No 15.67Supply, Installation , Testing & Commissioning  of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked.  Approval: UL/VDS/EN54. Make: ---- etc.,complete with all leadEach80535.080535.01.0FalseNoneNoneFalseNoneFalse80535.00
293243296734NoneV-6 Pg No 84 Itm No 15.66Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc.,complete with all leadEach3469.23469.22.0FalseNoneNoneFalseNoneFalse6938.40
293243396734NoneV-6 Pg No 92 Itm No 15.1Supply Installation testing & Commissioning of conventional type photo/Heat electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20 DegreeC to +60 DegreeC. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. ---- etc.,complete with all leadEach2601.92601.990.0FalseNoneNoneFalseNoneFalse234171.00
293243496734None077SITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. ---- etc.,complete with all leadEach7080.07080.05.0FalseNoneNoneFalseNoneFalse35400.00
293243596734NoneV-6 Pg No 84 Itm No 15.68Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon  with inbuilt isolator and  having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in -10 DegreeC to +55 DegreeC temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) ---- etc.,complete with all leadEach6071.16071.14.0FalseNoneNoneFalseNoneFalse24284.40
293243696734NoneV-6 Pg No 85 Itm No 15.73Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. ---- etc.,complete with all leadEach3717.03717.04.0FalseNoneNoneFalseNoneFalse14868.00
293243796734NoneV-6 Pg No 2 Itm No 1.4.2Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc.,complete with all leadEach146.2146.290.0FalseNoneNoneFalseNoneFalse13158.00
293243896734NoneV-6 Pg No 85 Itm No 15.72Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in -10 DegreeC to +55 DegreeC temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. ---- etc.,complete with all leadEach4832.14832.14.0FalseNoneNoneFalseNoneFalse19328.40
293243996734NoneV-6 Pg No 90 Itm No 15.113SITC of 7AM-12 V Battery for fire alarm system ---- etc.,complete with all leadEach1326.961326.964.0FalseNoneNoneFalseNoneFalse5307.840
17097048020000NoneNoneBuildingsConstruction of Burns Unit Hospital in the premises of BIMS at Belagavi in Belagavi District.-(Modular OT)5959768.18
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293244096735None001Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab. Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ( Note: The panel should be free from scratches & dents ) MODULAR OT area -8 mtr X6 mtr apprxt. Say 50.00 Sqm ---- etc.,complete with all leadSqm10354.510354.550.0FalseNoneNoneFalseNoneFalse517725.00
293244196735None002Providing and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ( Note: The panel should be free from scratches & dents ) 6 mtr X 3 mtr X2 Nos. =36 Sqmtr 8 mtr X 3 mtr X2 Nos. =48 Sqmtr Say 84.00 Sqm ( Door area will be detected form wall panel) ---- etc.,complete with all leadSqm10354.510354.584.0FalseNoneNoneFalseNoneFalse869778.00
293244296735None003Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. Srub Door /Dirty utility Door (single leaf) 1 mtr X 2.10 mtr Say 2.10 Sqmtr ---- etc.,complete with all leadSqm53843.453843.42.1FalseNoneNoneFalseNoneFalse113071.140
293244396735None004Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc.,complete with all leadSqm96585.3696585.363.5FalseNoneNoneFalseNoneFalse338048.760
293244496735None005Antistatic Epoxy Flooring : Providing and laying 4mm thick anti-static, anti-fungal and anti-bacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying self-leveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6- 8 hours. Then apply epoxy putty and allow for dry 6 - 8 hours. And then apply 2 mm thick self-leveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc.,complete with all leadSqm3835.03835.054.0FalseNoneNoneFalseNoneFalse207090.00
293244596735None006Supplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be less than 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF greater than 0.9, line voltage @ 50Hz, driver efficiency greater than 85% & THDless than15%. LED Efficiency greater than 130 Im/W & Fixture Efficiency greater than75lm/w with CRI greater than 75 with injection moulded Polycarbonate lens with less than 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition.] ---- etc.,complete with all leadEach9725.569725.568.0FalseNoneNoneFalseNoneFalse77804.480
293244696735None007Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X - ray viewing screen shall be concealed with wall panel. ---- etc.,complete with all leadEach33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
293244796735None008Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. ---- etc.,complete with all leadEach6903.06903.01.0FalseNoneNoneFalseNoneFalse6903.00
293244896735None009Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos. (Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc.,complete with all leadEach312700.0312700.01.0FalseNoneNoneFalseNoneFalse312700.00
293244996735None010Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. ---- etc.,complete with all leadEach70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
293245096735None011Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories. ---- etc.,complete with all leadEach76700.076700.01.0FalseNoneNoneFalseNoneFalse76700.00
293245196735None012Supplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following 1. Medical gas card 2. Laminar Air flow controls - Temperature & humidity indicators, filter status, temperature & humidity control. 3. Digital elapsed timer 4. Hand free phone 5. Digital day timer clock 6. Lighting control panel ---- etc.,complete with all leadEach129800.0129800.01.0FalseNoneNoneFalseNoneFalse129800.00
293245296735None013Providing & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc.,complete with all leadEach4130.04130.04.0FalseNoneNoneFalseNoneFalse16520.00
293245396735None014SUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc.,complete with all leadEach21240.021240.04.0FalseNoneNoneFalseNoneFalse84960.00
293245496735None015Supplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc.,complete with all leadEach7375.07375.01.0FalseNoneNoneFalseNoneFalse7375.00
293245596735None016SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, ( EFF1 Motor ) coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc.,complete with all leadNo597788.0597788.01.0FalseNoneNoneFalseNoneFalse597788.00
293245696735None017AIR COOLED CONDENSER UNIT & COPPER PIPING SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU) provided with necessary controls.like Thermostart , Draier with MS painted stand ---- etc.,complete with all leadNo146320.0146320.02.0FalseNoneNoneFalseNoneFalse292640.00
293245796735None018GRILLE & DAMPER SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size ---- etc.,complete with all leadSqm10384.010384.02.0FalseNoneNoneFalseNoneFalse20768.00
293245896735None019SUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts ---- etc.,complete with all leadSqm13924.013924.02.0FalseNoneNoneFalseNoneFalse27848.00
293245996735None020SUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 Degree C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. ---- etc.,complete with all leadNo6254.06254.01.0FalseNoneNoneFalseNoneFalse6254.00
293246096735None021SUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth ---- etc.,complete with all leadNo5546.05546.02.0FalseNoneNoneFalseNoneFalse11092.00
293246196735None022DUCTING & INSULATION SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges. 22 guage ---- etc.,complete with all leadSqm2006.02006.0160.0FalseNoneNoneFalseNoneFalse320960.00
293246296735None023SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade. 13 mm thk for return air duct ---- etc.,complete with all leadSqm920.4920.480.0FalseNoneNoneFalseNoneFalse73632.00
293246396735None024SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade. 19 mm thk for supply air duct ---- etc.,complete with all leadSqm1097.41097.490.0FalseNoneNoneFalseNoneFalse98766.00
293246496735None025Polishield covering with two coats paint for exposed duct ---- etc.,complete with all leadSqm1038.41038.470.0FalseNoneNoneFalseNoneFalse72688.00
293246596735None026SUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser ---- etc.,complete with all leadm979.4979.420.0FalseNoneNoneFalseNoneFalse19588.00
293246696735None02725 mm PVC dia drain piping with supports for AHUs ---- etc.,complete with all leadm625.4625.450.0FalseNoneNoneFalseNoneFalse31270.00
293246796735None028ELECTRICAL & CONTROLLS SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller For AHU ---- etc.,complete with all leadSet12272.012272.01.0FalseNoneNoneFalseNoneFalse12272.00
293246896735None029SUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60% ---- etc.,complete with all leadSet66788.066788.01.0FalseNoneNoneFalseNoneFalse66788.00
293246996735None030Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP - 4C X 6 Sqmm ---- etc.,complete with all leadm218.3218.360.0FalseNoneNoneFalseNoneFalse13098.00
293247096735None031Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP - 4C X 4 Sqmm ---- etc.,complete with all leadm177.0177.060.0FalseNoneNoneFalseNoneFalse10620.00
293247196735None032Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP - 4C X 2.5 Sqmm ---- etc.,complete with all leadm123.9123.930.0FalseNoneNoneFalseNoneFalse3717.00
293247296735None033Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP - 8C X 2.5 Sqmm S.R. ---- etc.,complete with all leadm348.1348.130.0FalseNoneNoneFalseNoneFalse10443.00
293247396735None034Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP - 4C X 10 Sqmm ---- etc.,complete with all leadm348.1348.130.0FalseNoneNoneFalseNoneFalse10443.00
293247496735None035SUPPLY & Fixing Cable trey -300 width x 50 ht perforated P. No.63 Item No.7.19.2 ---- etc.,complete with all leadm645.46645.4630.0FalseNoneNoneFalseNoneFalse19363.80
293247596735None036Plate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6 ---- etc.,complete with all leadm617.14617.1450.0FalseNoneNoneFalseNoneFalse30857.00
293247696735None037SUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure ---- etc.,complete with all leadNo10089.010089.01.0FalseNoneNoneFalseNoneFalse10089.00
293247796735None038DSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters ---- etc.,complete with all leadNo9735.09735.02.0FalseNoneNoneFalseNoneFalse19470.00
293247896735None039Supplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets (8 Nos), Data Points (1 Nos) and Medical Gas Outlets (7 Nos), 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand ---- etc.,complete with all leadNo194700.0194700.01.0FalseNoneNoneFalseNoneFalse194700.00
293247996735None040Supply , installation, testing and commissioning Double arm moveable pendant for surgeon with connected accessories. The Pendants shall comply with NFPA 99C/HTM 02-01/DIN/EN/ISO 7396-1 as amended up to the last date of receipt of tenders. The support arms shall be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position. Double moveable arms (any combination) with total coverage of min 1800 mm and minimum 330 Degree Each arm shall have ability of horizontal movement. Vertical movement shall be motorized and the arm height shall remain at a height greater than 6.5 feet above floor level. Weight carrying capacity of the arm shall not be less than 180 kg. It shall have electromagnetic/pneumatic brakes. Each arm shall be capable of minimum 330 Degree of rotation, which can be easily adjusted to suit the desired mode of operation. The pendant shall be European CE Certified with 4 digit notified body number/US FDA/ETL/UL/BIS certified/listed under medical devices directive. The Pendant Service Heads shall be modular with minimum 800mm head.The heads shall be capable of accepting a range of shelves, infusion poles, electrical switch/sockers, gas outlets and other required accessories. The Pendant Heads shall support the range of Physiological Monitor Mounting Solutions. The Pendant Service Heads shall be supplied with medical gas terminal units and 5A/15A or 6A/16 A hybrid sockets. Pendant shall be supplied with outlets and probes as mentioned below. Oxygen Outlets -2 nos , Medical Air Outlets 4 bar -1 no,Vacuum Outlets -2 nos ,Air(7bar) outlets-01 no, CO2 outlets-01 nos, Electrical Sockets-10 no, Adjustable shelf with two rails one on each side -3 no, Data socket RJ-45 -2 nos, IV Fluid Pole with 2 hooks -1 no, (Pole shall be capable of stacking 4 syringe pumps), Nitrous oxide outlets-1 no. Pendent shall provide cut-outs for patch panel in integrated OTs (only for integrated OTs.) Surgeon pendant shall have NIST connection for all gases to conncet the MGPLS system. ---- etc.,complete with all leadNo430700.0430700.01.0FalseNoneNoneFalseNoneFalse430700.00
293248096735None041Scrub Station MOT SCRUB STATION (minimum size 1500 mm) supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel (minimum thicknes 1.5 mm) and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.(built in with timer setting from 1 to 10 mic)It shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories. ---- etc.,complete with all leadNo278480.0278480.01.0FalseNoneNoneFalseNoneFalse278480.00
293248196735None042Supply , installation, testing and commissioning OT surgical Lighting system with connected accessroies MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology. Such lighting system shall have the following technical specifications: a) Number of light heads : Two b) Rotation system : 360 Degree c) Colour temperature range : 3800 Degree K to 5000 Degree K (Plus or minus 10%)-variable colour temperature. d) CRI : 93 Ra. e) LED's : Low temp . 3 Colours combination. f) LED bulb life : Greater than or equal 50,000 hrs. g) Field size diameter : 20 to 28 cm (Plus or minus 10%) h) Working range : 750 to 1100 mm (Plus or minus 10%) i) Focus : Adjustable 100mm-250mm. j) Illumination leve l: minimum 160,000 lux (both for major dome and minor dome separately). k) Controls : control panel ( two:one on the wall and other on dome/ digital with wireless remote). l) Power supply : 220 V/ 50Hz AC. ---- etc.,complete with all leadNo413118.0413118.01.0FalseNoneNoneFalseNoneFalse413118.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17097048020000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17097048020000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17097048020001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17097048400000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17097048500000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17097048760000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17097048920000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17097049040000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17097049130000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17097049220000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17097049310000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejectedNone
17097049410000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17097049490000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17097049860000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17097049950000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17097050050000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17097050160000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17097050250000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17097050700000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17097050800000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17097050880000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17097050970000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17097051050000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2023-24.None
17097051130000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation -2000.00 Cum,2)RCC and PCC - 910.00 Cum 3)Steel Reinforcement for RCC work- 80 Tonnes 4)Cement concrete Block Masonry/Solid Block Masonry/- 1800.00 Sqm 5)Flooring/Dadooing (Vitrified/ Granite/ Ceramic/ Cement concrete/cladding/ dadooing) -2200.00 Sqm,6)Plastering 6500.00 Sqm,7)Painting -5700.00 Sqm (8)MS grill- 2300.00 Kg, 9)WPC - 600.00 sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (c).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.70.00 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d). The letter of willingness of the sub contractor to be engaged for electrical works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.11.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e). The letter of willingness of the sub contractor to be engaged for water Supply works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(f) The Tenderer or his identified sub-contractor should have executed similar Fire Fighting works totaling to Rs.54.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (f). The letter of willingness of the sub contractor to be engaged for Fire Fighting works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(g) The Tenderer or his identified sub-contractor should have executed similar MGPLS works totaling to Rs.27.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (g). The letter of willingness of the sub contractor to be engaged for MGPLS works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(h) The Tenderer or his identified sub-contractor should have executed similar Modular OT works totaling to Rs.30.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (h). The letter of willingness of the sub contractor to be engaged for Modular OT works should be obtained and uploaded in the e-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(i) The Tenderer or his identified sub-contractor should have executed similar HVAC works totaling to Rs.35.00 Lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (i).The letter of willingness of the sub contractor to be engaged for HVAC works should be obtained and uploaded in the e-portalPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.471.60 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1 Min 10 cft capacity Concrete Mixer-2 Nos.2. Centering sheets-500 sqmtr 3.Tipper-2 Nos 4.Excavator-1 No.5.Water tanker-1 No 6.Bar, Bending and cutting machine 1 No.7.Generator 500 KVA 1 No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Receipt and invoice to be furnished.
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No,Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years -1 One No 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings and should have been working inpermanent role of the organization for at least two years-1 One No. Degree certificate and Experience Certificate to be furnished.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Degree certificate and Experience Certificate to be furnished.
NoneNoneNoneNoneKPWD Class-I Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class-I Registration Certificate issued by Competant Authority
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.1886.40 Lakhs. Note : a) For Clause 3.2 (a) the certificate duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.283.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level, of existing commitments and ongoing works to be completed during the next 11months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued by the officer not less than the rank of Executive Engineer Ongoing commitments and Bids submitted for the works.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD class-1 Registration Certificate issued by Competant AuthorityTrueTechnical Bid
Work done certificate issued by not below the rank of Executive Engineer.TrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GST clearance certificate in their nameTrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
Annual Turnover Certificate & profit & loss Certified balance sheet by Chartered AccountantTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsBelagaviBelagaviBelgaumNoneBIMS BelagaviNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1709712063000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road
streetNone
citybengaluru
stateKarnataka
pin560023
tenderRecallDTONone