1709184233000 | 1 | None | None | Other Works | Construction of Fire Escape Staircase with fire fighting works for Annex-3 building at BBMP Head office, Bengaluru | 68826837.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2852234 | 92563 | None | BBMPFIRE001 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Stilt Floor) | Sqm | 186.91 | 186.91 | 7.425 | False | None | None | False | None | False | 1387.80675 | 0 | 2852235 | 92563 | None | BBMPFIRE002 | Earthwork excavation for foundation by mechanical means for all works & depth upto 3m as per the drawing and technical specification, including setting out, shorting, strutting, barricading, caution lights, including dredssing of excavated surface dispossing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m in all kinds of soils depth upto 3 m (Stilt floor) | Cum | 132.4 | 132.4 | 416.88 | False | None | None | False | None | False | 55194.912 | 0 | 2852236 | 92563 | None | BBMPFIRE003 | Providing and injecting chemical emulsion for Pre-constructional
Anti-Termite Treatment, creating continuous chemical barrier under
and around the column pits, walls, trenches, basement excavation, top
surface of the plinth filling, junction of wall and floor, along the external
perimeter of building, expansion joints, over the top surface of consolidated
earth on which apron is to be laid, surrounding of pipes and conduits with
Chlorpyriphos20% E.C. / Lindane 20% E.C. @ 3.19 l/m2
including cost of
chemical, diluting in water to one percent concentration, labour, usage
charges of machinery, complete as per specifications.(Stilt floor) | Sqm | 153.16 | 153.16 | 162.88 | False | None | None | False | None | False | 24946.7008 | 0 | 2852237 | 92563 | None | BBMPFIRE004 | Providing and Filling in foundation with granite/trap broken metal 100mm. and down size & with approved sand including handpacking, ramming, watering, ncluding cost of all materials and labour with all lead and lift complete as per specifications.(Stilt floor) | Cum | 3481.24 | 3481.24 | 32.576 | False | None | None | False | None | False | 113404.87424 | 0 | 2852238 | 92563 | None | BBMPFIRE005 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 7351.87 | 7351.87 | 13.65 | False | None | None | False | None | False | 100353.0255 | 0 | 2852239 | 92563 | None | BBMPFIRE006 | Epoxy bonding of new concrete to old concrete (Stilt Floor) | Sqm | 1000.75 | 1000.75 | 9.24 | False | None | None | False | None | False | 9246.93 | 0 | 2852240 | 92563 | None | BBMPFIRE007 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(stilt floor) | Cum | 9110.56 | 9110.56 | 49.68 | False | None | None | False | None | False | 452612.6208 | 0 | 2852241 | 92563 | None | BBMPFIRE008 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Stilt Floor) | Sqm | 711.3 | 711.3 | 28.5 | False | None | None | False | None | False | 20272.05 | 0 | 2852242 | 92563 | None | BBMPFIRE009 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m(Stilt Floor) | Cum | 345.27 | 345.27 | 341.104 | False | None | None | False | None | False | 117772.97808 | 0 | 2852243 | 92563 | None | BBMPFIRE0010 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Column upto GL) | Cum | 14876.9 | 14876.9 | 3.435 | False | None | None | False | None | False | 51102.1515 | 0 | 2852244 | 92563 | None | BBMPFIRE011 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Shear Wall upto GL) | Cum | 9626.23 | 9626.23 | 2.58 | False | None | None | False | None | False | 24835.6734 | 0 | 2852245 | 92563 | None | BBMPFIRE012 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Grade/Plinth Beam) | Cum | 13126.67 | 13126.67 | 3.138 | False | None | None | False | None | False | 41191.49046 | 0 | 2852246 | 92563 | None | BBMPFIRE013 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Column) | Cum | 15461.64 | 15461.64 | 2.79 | False | None | None | False | None | False | 43137.9756 | 0 | 2852247 | 92563 | None | BBMPFIRE014 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Shear Wall) | Cum | 10004.59 | 10004.59 | 8.01 | False | None | None | False | None | False | 80136.7659 | 0 | 2852248 | 92563 | None | BBMPFIRE015 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Roof Beam) | Cum | 14552.13 | 14552.13 | 4.5624 | False | None | None | False | None | False | 66392.637912 | 0 | 2852249 | 92563 | None | BBMPFIRE016 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Staircase) | Cum | 13642.62 | 13642.62 | 8.56 | False | None | None | False | None | False | 116780.8272 | 0 | 2852250 | 92563 | None | BBMPFIRE017 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Ramp & Flooring) | Cum | 9466.31 | 9466.31 | 11.26 | False | None | None | False | None | False | 106590.6506 | 0 | 2852251 | 92563 | None | BBMPFIRE018 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Stilt Floor) | t | 116115.18 | 116115.18 | 19.92 | False | None | None | False | None | False | 2313014.3856 | 0 | 2852252 | 92563 | None | BBMPFIRE019 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Stilt Floor) | Sqm | 1700.37 | 1700.37 | 67.323 | False | None | None | False | None | False | 114474.00951 | 0 | 2852253 | 92563 | None | BBMPFIRE020 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Stilt Floor) | Sqm | 481.55 | 481.55 | 381.1545 | False | None | None | False | None | False | 183544.949475 | 0 | 2852254 | 92563 | None | BBMPFIRE021 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Stilt Floor) | Sqm | 362.14 | 362.14 | 231.12 | False | None | None | False | None | False | 83697.7968 | 0 | 2852255 | 92563 | None | BBMPFIRE022 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (Stilt Floor) | Sqm | 10742.24 | 10742.24 | 12.41 | False | None | None | False | None | False | 133311.1984 | 0 | 2852256 | 92563 | None | BBMPFIRE023 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (Stilt Floor) | Sqm | 3701.89 | 3701.89 | 76.27 | False | None | None | False | None | False | 282343.1503 | 0 | 2852257 | 92563 | None | BBMPFIRE024 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (Stilt Floor) | Sqm | 5199.78 | 5199.78 | 4.57 | False | None | None | False | None | False | 23762.9946 | 0 | 2852258 | 92563 | None | BBMPFIRE025 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Stilt Floor) | m | 425.74 | 425.74 | 42.9 | False | None | None | False | None | False | 18264.246 | 0 | 2852259 | 92563 | None | BBMPFIRE026 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Stilt Floor) | Sqm | 225.85 | 225.85 | 59.1 | False | None | None | False | None | False | 13347.735 | 0 | 2852260 | 92563 | None | BBMPFIRE027 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (Stilt Floor) | Sqm | 129.79 | 129.79 | 392.66 | False | None | None | False | None | False | 50963.3414 | 0 | 2852261 | 92563 | None | BBMPFIRE028 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Stilt Floor) | Sqm | 68.79 | 68.79 | 392.66 | False | None | None | False | None | False | 27011.0814 | 0 | 2852262 | 92563 | None | BBMPFIRE029 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Stilt Floor) | Sqm | 164.84 | 164.84 | 392.66 | False | None | None | False | None | False | 64726.0744 | 0 | 2852263 | 92563 | None | BBMPFIRE030 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Stilt Floor) | Sqm | 180.42 | 180.42 | 131.13 | False | None | None | False | None | False | 23658.4746 | 0 | 2852264 | 92563 | None | BBMPFIRE031 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Stilt Floor) | Kg | 733.37 | 733.37 | 192.0 | False | None | None | False | None | False | 140807.04 | 0 | 2852265 | 92563 | None | BBMPFIRE032 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Stilt Floor) | Cum | 110.33 | 110.33 | 7.425 | False | None | None | False | None | False | 819.20025 | 0 | 2852266 | 92563 | None | BBMPFIRE033 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Ground Floor) | Sqm | 188.78 | 188.78 | 7.425 | False | None | None | False | None | False | 1401.6915 | 0 | 2852267 | 92563 | None | BBMPFIRE034 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (Ground Floor) | Sqm | 1371.28 | 1371.28 | 3.15 | False | None | None | False | None | False | 4319.532 | 0 | 2852268 | 92563 | None | BBMPFIRE035 | Dismantling doors, windows and clerestory windows (steel or wood) shut ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below (Ground Floor) | Cum | 314.63 | 314.63 | 0.945 | False | None | None | False | None | False | 297.32535 | 0 | 2852269 | 92563 | None | BBMPFIRE036 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Ground Floor) | Cum | 3180.43 | 3180.43 | 1.863 | False | None | None | False | None | False | 5925.14109 | 0 | 2852270 | 92563 | None | BBMPFIRE037 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Ground Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852271 | 92563 | None | BBMPFIRE038 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Ground Floor) | Sqm | 718.41 | 718.41 | 43.8 | False | None | None | False | None | False | 31466.358 | 0 | 2852272 | 92563 | None | BBMPFIRE039 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Ground Floor) (Column) | Cum | 15616.26 | 15616.26 | 1.98 | False | None | None | False | None | False | 30920.1948 | 0 | 2852273 | 92563 | None | BBMPFIRE040 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Ground Floor) (Shear Wall) | Cum | 10104.64 | 10104.64 | 8.01 | False | None | None | False | None | False | 80938.1664 | 0 | 2852274 | 92563 | None | BBMPFIRE041 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Ground Floor) (Roof Beams) | Cum | 14697.65 | 14697.65 | 4.67 | False | None | None | False | None | False | 68638.0255 | 0 | 2852275 | 92563 | None | BBMPFIRE042 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Ground Floor) (Staircase) | Cum | 13779.05 | 13779.05 | 8.1 | False | None | None | False | None | False | 111610.305 | 0 | 2852276 | 92563 | None | BBMPFIRE043 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Ground Floor) (Cill & Lintel) | Cum | 13906.87 | 13906.87 | 0.21 | False | None | None | False | None | False | 2920.4427 | 0 | 2852277 | 92563 | None | BBMPFIRE044 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Ground Floor) (Chajja) | Cum | 12603.1 | 12603.1 | 0.9315 | False | None | None | False | None | False | 11739.78765 | 0 | 2852278 | 92563 | None | BBMPFIRE045 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Ground Floor) | t | 117276.33 | 117276.33 | 4.41 | False | None | None | False | None | False | 517188.6153 | 0 | 2852279 | 92563 | None | BBMPFIRE046 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Ground Floor) | Sqm | 1717.38 | 1717.38 | 40.35 | False | None | None | False | None | False | 69296.283 | 0 | 2852280 | 92563 | None | BBMPFIRE047 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Ground Floor) | Sqm | 486.37 | 486.37 | 63.05 | False | None | None | False | None | False | 30665.6285 | 0 | 2852281 | 92563 | None | BBMPFIRE048 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Ground Floor) | Sqm | 365.76 | 365.76 | 213.79 | False | None | None | False | None | False | 78195.8304 | 0 | 2852282 | 92563 | None | BBMPFIRE049 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Ground Floor) | Sqm | 8588.22 | 8588.22 | 4.86 | False | None | None | False | None | False | 41738.7492 | 0 | 2852283 | 92563 | None | BBMPFIRE050 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (Ground Floor) | Kg | 239.9 | 239.9 | 102.06 | False | None | None | False | None | False | 24484.194 | 0 | 2852284 | 92563 | None | BBMPFIRE051 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (Ground Floor) | Sqm | 3738.91 | 3738.91 | 38.23 | False | None | None | False | None | False | 142938.5293 | 0 | 2852285 | 92563 | None | BBMPFIRE052 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (Ground Floor) | Sqm | 5251.78 | 5251.78 | 4.57 | False | None | None | False | None | False | 24000.6346 | 0 | 2852286 | 92563 | None | BBMPFIRE053 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Ground Floor) | m | 430.0 | 430.0 | 42.9 | False | None | None | False | None | False | 18447.0 | 0 | 2852287 | 92563 | None | BBMPFIRE054 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Ground Floor) | Sqm | 228.11 | 228.11 | 63.05 | False | None | None | False | None | False | 14382.3355 | 0 | 2852288 | 92563 | None | BBMPFIRE055 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (Ground Floor) | Sqm | 131.09 | 131.09 | 213.7 | False | None | None | False | None | False | 28013.933 | 0 | 2852289 | 92563 | None | BBMPFIRE056 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Ground Floor) | Sqm | 69.48 | 69.48 | 213.79 | False | None | None | False | None | False | 14854.1292 | 0 | 2852290 | 92563 | None | BBMPFIRE057 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Ground Floor) | Sqm | 166.49 | 166.49 | 213.79 | False | None | None | False | None | False | 35593.8971 | 0 | 2852291 | 92563 | None | BBMPFIRE058 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Ground Floor) | Sqm | 182.22 | 182.22 | 141.822 | False | None | None | False | None | False | 25842.80484 | 0 | 2852292 | 92563 | None | BBMPFIRE059 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Ground Floor) | Kg | 740.7 | 740.7 | 108.0 | False | None | None | False | None | False | 79995.6 | 0 | 2852293 | 92563 | None | BBMPFIRE060 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Ground Floor) | Cum | 111.43 | 111.43 | 2.8 | False | None | None | False | None | False | 312.004 | 0 | 2852294 | 92563 | None | BBMPFIRE061 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (First Floor) | Sqm | 190.65 | 190.65 | 7.425 | False | None | None | False | None | False | 1415.57625 | 0 | 2852295 | 92563 | None | BBMPFIRE062 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping First, all complete as per direction of Engineer-in-Charge. (First Floor) | Sqm | 1384.86 | 1384.86 | 3.15 | False | None | None | False | None | False | 4362.309 | 0 | 2852296 | 92563 | None | BBMPFIRE063 | Dismantling doors, windows and clerestory windows (steel or wood) shut ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below (First Floor) | Cum | 317.75 | 317.75 | 0.94 | False | None | None | False | None | False | 298.685 | 0 | 2852297 | 92563 | None | BBMPFIRE064 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (First Floor) | Cum | 3211.92 | 3211.92 | 3.26 | False | None | None | False | None | False | 10470.8592 | 0 | 2852298 | 92563 | None | BBMPFIRE065 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (First Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852299 | 92563 | None | BBMPFIRE066 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (First Floor) | Sqm | 725.53 | 725.53 | 43.8 | False | None | None | False | None | False | 31778.214 | 0 | 2852300 | 92563 | None | BBMPFIRE067 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (First Floor) (Column) | Cum | 15770.87 | 15770.87 | 1.98 | False | None | None | False | None | False | 31226.3226 | 0 | 2852301 | 92563 | None | BBMPFIRE068 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (First Floor) (Shear Wall) | Cum | 10204.68 | 10204.68 | 8.01 | False | None | None | False | None | False | 81739.4868 | 0 | 2852302 | 92563 | None | BBMPFIRE069 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (First Floor) (Roof Beams) | Cum | 14843.18 | 14843.18 | 4.67 | False | None | None | False | None | False | 69317.6506 | 0 | 2852303 | 92563 | None | BBMPFIRE070 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (First Floor) (Staircase) | Cum | 13915.48 | 13915.48 | 8.1 | False | None | None | False | None | False | 112715.388 | 0 | 2852304 | 92563 | None | BBMPFIRE071 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (First Floor) (Cill & Lintel) | Cum | 14044.5 | 14044.5 | 0.21 | False | None | None | False | None | False | 2949.345 | 0 | 2852305 | 92563 | None | BBMPFIRE072 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (First Floor) (Chajja) | Cum | 12727.88 | 12727.88 | 0.9315 | False | None | None | False | None | False | 11856.02022 | 0 | 2852306 | 92563 | None | BBMPFIRE073 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (First Floor) | t | 118437.48 | 118437.48 | 4.41 | False | None | None | False | None | False | 522309.2868 | 0 | 2852307 | 92563 | None | BBMPFIRE074 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (First Floor) | Sqm | 1734.38 | 1734.38 | 40.35 | False | None | None | False | None | False | 69982.233 | 0 | 2852308 | 92563 | None | BBMPFIRE075 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (First Floor) | Sqm | 491.18 | 491.18 | 92.75 | False | None | None | False | None | False | 45556.945 | 0 | 2852309 | 92563 | None | BBMPFIRE076 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (First Floor) | Sqm | 369.38 | 369.38 | 213.79 | False | None | None | False | None | False | 78969.7502 | 0 | 2852310 | 92563 | None | BBMPFIRE077 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (First Floor) | Sqm | 8673.26 | 8673.26 | 4.86 | False | None | None | False | None | False | 42152.0436 | 0 | 2852311 | 92563 | None | BBMPFIRE078 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (First Floor) | Kgs | 242.28 | 242.28 | 102.06 | False | None | None | False | None | False | 24727.0968 | 0 | 2852312 | 92563 | None | BBMPFIRE079 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (First Floor) | Sqm | 3775.93 | 3775.93 | 38.23 | False | None | None | False | None | False | 144353.8039 | 0 | 2852313 | 92563 | None | BBMPFIRE080 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (First Floor) | Sqm | 5303.78 | 5303.78 | 4.574 | False | None | None | False | None | False | 24259.48972 | 0 | 2852314 | 92563 | None | BBMPFIRE081 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (First Floor) | m | 434.25 | 434.25 | 42.9 | False | None | None | False | None | False | 18629.325 | 0 | 2852315 | 92563 | None | BBMPFIRE082 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (First Floor) | Sqm | 230.36 | 230.36 | 92.75 | False | None | None | False | None | False | 21365.89 | 0 | 2852316 | 92563 | None | BBMPFIRE083 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (First Floor) | Sqm | 132.39 | 132.39 | 213.79 | False | None | None | False | None | False | 28303.6581 | 0 | 2852317 | 92563 | None | BBMPFIRE084 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (First Floor) | Sqm | 70.16 | 70.16 | 213.79 | False | None | None | False | None | False | 14999.5064 | 0 | 2852318 | 92563 | None | BBMPFIRE085 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (First Floor) | Sqm | 168.14 | 168.14 | 213.79 | False | None | None | False | None | False | 35946.6506 | 0 | 2852319 | 92563 | None | BBMPFIRE086 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (First Floor) | Sqm | 184.03 | 184.03 | 141.822 | False | None | None | False | None | False | 26099.50266 | 0 | 2852320 | 92563 | None | BBMPFIRE087 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (First Floor) | Kgs | 748.03 | 748.03 | 108.0 | False | None | None | False | None | False | 80787.24 | 0 | 2852321 | 92563 | None | BBMPFIRE088 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (First Floor) | Cum | 112.53 | 112.53 | 4.2 | False | None | None | False | None | False | 472.626 | 0 | 2852322 | 92563 | None | BBMPFIRE089 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Second Floor) | Sqm | 192.51 | 192.51 | 7.425 | False | None | None | False | None | False | 1429.38675 | 0 | 2852323 | 92563 | None | BBMPFIRE090 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping Second, all complete as per direction of Engineer-in-Charge. (Second Floor) | Sqm | 1398.43 | 1398.43 | 3.15 | False | None | None | False | None | False | 4405.0545 | 0 | 2852324 | 92563 | None | BBMPFIRE091 | Dismantling doors, windows and clerestory windows (steel or wood) shut ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below (Second Floor) | Cum | 320.86 | 320.86 | 0.94 | False | None | None | False | None | False | 301.6084 | 0 | 2852325 | 92563 | None | BBMPFIRE092 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Second Floor) | Cum | 3243.41 | 3243.41 | 3.26 | False | None | None | False | None | False | 10573.5166 | 0 | 2852326 | 92563 | None | BBMPFIRE093 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Second Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852327 | 92563 | None | BBMPFIRE094 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Second Floor) | Sqm | 732.64 | 732.64 | 43.8 | False | None | None | False | None | False | 32089.632 | 0 | 2852328 | 92563 | None | BBMPFIRE095 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Second Floor) (Column) | Cum | 15925.49 | 15925.49 | 1.98 | False | None | None | False | None | False | 31532.4702 | 0 | 2852329 | 92563 | None | BBMPFIRE096 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Second Floor) (Shear Wall) | Cum | 10304.73 | 10304.73 | 8.01 | False | None | None | False | None | False | 82540.8873 | 0 | 2852330 | 92563 | None | BBMPFIRE097 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Second Floor) (Roof Beams) | Cum | 14988.7 | 14988.7 | 4.67 | False | None | None | False | None | False | 69997.229 | 0 | 2852331 | 92563 | None | BBMPFIRE098 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Second Floor) (Staircase) | Cum | 14051.9 | 14051.9 | 8.1 | False | None | None | False | None | False | 113820.39 | 0 | 2852332 | 92563 | None | BBMPFIRE099 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Second Floor) (Cill & Lintel) | Cum | 14182.25 | 14182.25 | 0.21 | False | None | None | False | None | False | 2978.2725 | 0 | 2852333 | 92563 | None | BBMPFIRE100 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Second Floor) (Chajja) | Cum | 12852.67 | 12852.67 | 0.9315 | False | None | None | False | None | False | 11972.262105 | 0 | 2852334 | 92563 | None | BBMPFIRE101 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Second Floor) | t | 119598.64 | 119598.64 | 4.41 | False | None | None | False | None | False | 527430.0024 | 0 | 2852335 | 92563 | None | BBMPFIRE102 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Second Floor) | Sqm | 1751.39 | 1751.39 | 40.35 | False | None | None | False | None | False | 70668.5865 | 0 | 2852336 | 92563 | None | BBMPFIRE103 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Second Floor) | Sqm | 496.0 | 496.0 | 92.75 | False | None | None | False | None | False | 46004.0 | 0 | 2852337 | 92563 | None | BBMPFIRE104 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Second Floor) | Sqm | 373.0 | 373.0 | 213.79 | False | None | None | False | None | False | 79743.67 | 0 | 2852338 | 92563 | None | BBMPFIRE105 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Second Floor) | Sqm | 8758.29 | 8758.29 | 4.86 | False | None | None | False | None | False | 42565.2894 | 0 | 2852339 | 92563 | None | BBMPFIRE106 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (Second Floor) | Kgs | 244.66 | 244.66 | 102.06 | False | None | None | False | None | False | 24969.9996 | 0 | 2852340 | 92563 | None | BBMPFIRE107 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (Second Floor) | Sqm | 3812.95 | 3812.95 | 38.23 | False | None | None | False | None | False | 145769.0785 | 0 | 2852341 | 92563 | None | BBMPFIRE108 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (Second Floor) | Sqm | 5355.78 | 5355.78 | 4.57 | False | None | None | False | None | False | 24475.9146 | 0 | 2852342 | 92563 | None | BBMPFIRE109 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Second Floor) | m | 438.51 | 438.51 | 42.9 | False | None | None | False | None | False | 18812.079 | 0 | 2852343 | 92563 | None | BBMPFIRE110 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Second Floor) | Sqm | 232.62 | 232.62 | 92.75 | False | None | None | False | None | False | 21575.505 | 0 | 2852344 | 92563 | None | BBMPFIRE111 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (Second Floor) | Sqm | 133.69 | 133.69 | 213.79 | False | None | None | False | None | False | 28581.5851 | 0 | 2852345 | 92563 | None | BBMPFIRE112 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Second Floor) | Sqm | 70.85 | 70.85 | 213.79 | False | None | None | False | None | False | 15147.0215 | 0 | 2852346 | 92563 | None | BBMPFIRE113 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Second Floor) | Sqm | 169.79 | 169.79 | 213.79 | False | None | None | False | None | False | 36299.4041 | 0 | 2852347 | 92563 | None | BBMPFIRE114 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Second Floor) | Sqm | 185.83 | 185.83 | 141.822 | False | None | None | False | None | False | 26354.78226 | 0 | 2852348 | 92563 | None | BBMPFIRE115 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Second Floor) | Kgs | 755.37 | 755.37 | 108.0 | False | None | None | False | None | False | 81579.96 | 0 | 2852349 | 92563 | None | BBMPFIRE116 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Second Floor) | Cum | 113.63 | 113.63 | 4.2 | False | None | None | False | None | False | 477.246 | 0 | 2852350 | 92563 | None | BBMPFIRE117 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Third Floor) | Sqm | 194.38 | 194.38 | 7.425 | False | None | None | False | None | False | 1443.2715 | 0 | 2852351 | 92563 | None | BBMPFIRE118 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping Third, all complete as per direction of Engineer-in-Charge. (Third Floor) | Sqm | 1412.01 | 1412.01 | 3.15 | False | None | None | False | None | False | 4447.8315 | 0 | 2852352 | 92563 | None | BBMPFIRE119 | Dismantling doors, windows and clerestory windows (steel or wood) shut ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below (Third Floor) | Cum | 323.9 | 323.9 | 0.945 | False | None | None | False | None | False | 306.0855 | 0 | 2852353 | 92563 | None | BBMPFIRE120 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Third Floor) | Cum | 3274.9 | 3274.9 | 3.26 | False | None | None | False | None | False | 10676.174 | 0 | 2852354 | 92563 | None | BBMPFIRE121 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Third Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852355 | 92563 | None | BBMPFIRE122 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Third Floor) | Sqm | 739.75 | 739.75 | 43.8 | False | None | None | False | None | False | 32401.05 | 0 | 2852356 | 92563 | None | BBMPFIRE123 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Third Floor) (Column) | Cum | 16080.11 | 16080.11 | 1.98 | False | None | None | False | None | False | 31838.6178 | 0 | 2852357 | 92563 | None | BBMPFIRE124 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Third Floor) (Shear Wall) | Cum | 10404.77 | 10404.77 | 8.01 | False | None | None | False | None | False | 83342.2077 | 0 | 2852358 | 92563 | None | BBMPFIRE125 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Third Floor) (Roof Beams) | Cum | 15134.22 | 15134.22 | 4.67 | False | None | None | False | None | False | 70676.8074 | 0 | 2852359 | 92563 | None | BBMPFIRE126 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Third Floor) (Staircase) | Cum | 14188.33 | 14188.33 | 8.1 | False | None | None | False | None | False | 114925.473 | 0 | 2852360 | 92563 | None | BBMPFIRE127 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Third Floor) (Cill & Lintel) | Cum | 14319.95 | 14319.95 | 0.21 | False | None | None | False | None | False | 3007.1895 | 0 | 2852361 | 92563 | None | BBMPFIRE128 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Third Floor) (Chajja) | Cum | 12977.45 | 12977.45 | 0.9315 | False | None | None | False | None | False | 12088.494675 | 0 | 2852362 | 92563 | None | BBMPFIRE129 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Third Floor) | t | 120759.79 | 120759.79 | 4.41 | False | None | None | False | None | False | 532550.6739 | 0 | 2852363 | 92563 | None | BBMPFIRE130 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Third Floor) | Sqm | 1768.39 | 1768.39 | 40.35 | False | None | None | False | None | False | 71354.5365 | 0 | 2852364 | 92563 | None | BBMPFIRE131 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Third Floor) | Sqm | 500.82 | 500.82 | 92.75 | False | None | None | False | None | False | 46451.055 | 0 | 2852365 | 92563 | None | BBMPFIRE132 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Third Floor) | Sqm | 376.62 | 376.62 | 213.79 | False | None | None | False | None | False | 80517.5898 | 0 | 2852366 | 92563 | None | BBMPFIRE133 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Third Floor) | Sqm | 8843.32 | 8843.32 | 4.86 | False | None | None | False | None | False | 42978.5352 | 0 | 2852367 | 92563 | None | BBMPFIRE134 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (Third Floor) | Kgs | 247.03 | 247.03 | 102.06 | False | None | None | False | None | False | 25211.8818 | 0 | 2852368 | 92563 | None | BBMPFIRE135 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (Third Floor) | Sqm | 3849.97 | 3849.97 | 38.23 | False | None | None | False | None | False | 147184.3531 | 0 | 2852369 | 92563 | None | BBMPFIRE136 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (Third Floor) | Sqm | 5407.77 | 5407.77 | 4.57 | False | None | None | False | None | False | 24713.5089 | 0 | 2852370 | 92563 | None | BBMPFIRE137 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Third Floor) | m | 442.77 | 442.77 | 42.9 | False | None | None | False | None | False | 18994.833 | 0 | 2852371 | 92563 | None | BBMPFIRE138 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Third Floor) | Sqm | 234.8 | 234.8 | 92.75 | False | None | None | False | None | False | 21777.7 | 0 | 2852372 | 92563 | None | BBMPFIRE139 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (Third Floor) | Sqm | 134.9 | 134.9 | 213.79 | False | None | None | False | None | False | 28840.271 | 0 | 2852373 | 92563 | None | BBMPFIRE140 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Third Floor) | Sqm | 71.54 | 71.54 | 213.79 | False | None | None | False | None | False | 15294.5366 | 0 | 2852374 | 92563 | None | BBMPFIRE141 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Third Floor) | Sqm | 171.43 | 171.43 | 213.79 | False | None | None | False | None | False | 36650.0197 | 0 | 2852375 | 92563 | None | BBMPFIRE142 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Third Floor) | Sqm | 187.63 | 187.63 | 141.822 | False | None | None | False | None | False | 26610.06186 | 0 | 2852376 | 92563 | None | BBMPFIRE143 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Third Floor) | Kgs | 762.7 | 762.7 | 108.0 | False | None | None | False | None | False | 82371.6 | 0 | 2852377 | 92563 | None | BBMPFIRE144 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Third Floor) | Cum | 114.74 | 114.74 | 4.2 | False | None | None | False | None | False | 481.908 | 0 | 2852378 | 92563 | None | BBMPFIRE145 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Fourth Floor) | Sqm | 196.25 | 196.25 | 7.425 | False | None | None | False | None | False | 1457.15625 | 0 | 2852379 | 92563 | None | BBMPFIRE146 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping Fourth, all complete as per direction of Engineer-in-Charge. (Fourth Floor) | Sqm | 1425.59 | 1425.59 | 3.15 | False | None | None | False | None | False | 4490.6085 | 0 | 2852380 | 92563 | None | BBMPFIRE147 | Dismantling doors, windows and clerestory windows (steel or wood) shut ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below (Fourth Floor) | Cum | 327.09 | 327.09 | 0.94 | False | None | None | False | None | False | 307.4646 | 0 | 2852381 | 92563 | None | BBMPFIRE148 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Fourth Floor) | Cum | 3306.39 | 3306.39 | 3.26 | False | None | None | False | None | False | 10778.8314 | 0 | 2852382 | 92563 | None | BBMPFIRE149 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Fourth Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852383 | 92563 | None | BBMPFIRE150 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Fourth Floor) | Sqm | 746.86 | 746.86 | 43.8 | False | None | None | False | None | False | 32712.468 | 0 | 2852384 | 92563 | None | BBMPFIRE151 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fourth Floor) (Column) | Cum | 16234.72 | 16234.72 | 1.98 | False | None | None | False | None | False | 32144.7456 | 0 | 2852385 | 92563 | None | BBMPFIRE152 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fourth Floor) (Shear Wall) | Cum | 10504.82 | 10504.82 | 8.01 | False | None | None | False | None | False | 84143.6082 | 0 | 2852386 | 92563 | None | BBMPFIRE153 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fourth Floor) (Roof Beams) | Cum | 15279.74 | 15279.74 | 4.67 | False | None | None | False | None | False | 71356.3858 | 0 | 2852387 | 92563 | None | BBMPFIRE154 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fourth Floor) (Staircase) | Cum | 14324.76 | 14324.76 | 8.104 | False | None | None | False | None | False | 116087.85504 | 0 | 2852388 | 92563 | None | BBMPFIRE155 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fourth Floor) (Cill & Lintel) | Cum | 14457.64 | 14457.64 | 0.21 | False | None | None | False | None | False | 3036.1044 | 0 | 2852389 | 92563 | None | BBMPFIRE156 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fourth Floor) (Chajja) | Cum | 13102.23 | 13102.23 | 0.9315 | False | None | None | False | None | False | 12204.727245 | 0 | 2852390 | 92563 | None | BBMPFIRE157 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Fourth Floor) | t | 121920.94 | 121920.94 | 4.41 | False | None | None | False | None | False | 537671.3454 | 0 | 2852391 | 92563 | None | BBMPFIRE158 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Fourth Floor) | Sqm | 1785.39 | 1785.39 | 40.35 | False | None | None | False | None | False | 72040.4865 | 0 | 2852392 | 92563 | None | BBMPFIRE159 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Fourth Floor) | Sqm | 505.63 | 505.63 | 92.75 | False | None | None | False | None | False | 46897.1825 | 0 | 2852393 | 92563 | None | BBMPFIRE160 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Fourth Floor) | Sqm | 380.24 | 380.24 | 213.79 | False | None | None | False | None | False | 81291.5096 | 0 | 2852394 | 92563 | None | BBMPFIRE161 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Fourth Floor) | Sqm | 8928.35 | 8928.35 | 4.86 | False | None | None | False | None | False | 43391.781 | 0 | 2852395 | 92563 | None | BBMPFIRE162 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (Fourth Floor) | Kgs | 249.41 | 249.41 | 102.06 | False | None | None | False | None | False | 25454.7846 | 0 | 2852396 | 92563 | None | BBMPFIRE163 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (Fourth Floor) | Sqm | 3886.99 | 3886.99 | 38.23 | False | None | None | False | None | False | 148599.6277 | 0 | 2852397 | 92563 | None | BBMPFIRE164 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (Fourth Floor) | Sqm | 5459.77 | 5459.77 | 4.57 | False | None | None | False | None | False | 24951.1489 | 0 | 2852398 | 92563 | None | BBMPFIRE165 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Fourth Floor) | m | 447.03 | 447.03 | 42.9 | False | None | None | False | None | False | 19177.587 | 0 | 2852399 | 92563 | None | BBMPFIRE166 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fourth Floor) | Sqm | 237.14 | 237.14 | 92.75 | False | None | None | False | None | False | 21994.735 | 0 | 2852400 | 92563 | None | BBMPFIRE167 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (Fourth Floor) | Sqm | 136.29 | 136.29 | 213.79 | False | None | None | False | None | False | 29137.4391 | 0 | 2852401 | 92563 | None | BBMPFIRE168 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fourth Floor) | Sqm | 72.23 | 72.23 | 213.797 | False | None | None | False | None | False | 15442.55731 | 0 | 2852402 | 92563 | None | BBMPFIRE169 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fourth Floor) | Sqm | 173.08 | 173.08 | 213.7 | False | None | None | False | None | False | 36987.196 | 0 | 2852403 | 92563 | None | BBMPFIRE170 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fourth Floor) | Sqm | 189.44 | 189.44 | 141.822 | False | None | None | False | None | False | 26866.75968 | 0 | 2852404 | 92563 | None | BBMPFIRE171 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Fourth Floor) | Kgs | 770.03 | 770.03 | 108.0 | False | None | None | False | None | False | 83163.24 | 0 | 2852405 | 92563 | None | BBMPFIRE172 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Fourth Floor) | Cum | 115.84 | 115.84 | 4.2 | False | None | None | False | None | False | 486.528 | 0 | 2852406 | 92563 | None | BBMPFIRE173 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Fifth Floor) | Sqm | 198.12 | 198.12 | 7.425 | False | None | None | False | None | False | 1471.041 | 0 | 2852407 | 92563 | None | BBMPFIRE174 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping Fifth, all complete as per direction of Engineer-in-Charge. (Fifth Floor) | Sqm | 1439.17 | 1439.17 | 3.15 | False | None | None | False | None | False | 4533.3855 | 0 | 2852408 | 92563 | None | BBMPFIRE175 | Dismantling doors, windows and clerestory windows (steel or wood) shut ter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineer-in-charge. Of area 3 m² and below (Fifth Floor) | Cum | 330.21 | 330.21 | 0.94 | False | None | None | False | None | False | 310.3974 | 0 | 2852409 | 92563 | None | BBMPFIRE176 | Demolishing R.C.C. work manually/ by mechanical means including stack ing of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. (Fifth Floor) | Cum | 3337.88 | 3337.88 | 3.26 | False | None | None | False | None | False | 10881.4888 | 0 | 2852410 | 92563 | None | BBMPFIRE177 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Fifth Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852411 | 92563 | None | BBMPFIRE178 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Fifth Floor) | Sqm | 753.98 | 753.98 | 43.8 | False | None | None | False | None | False | 33024.324 | 0 | 2852412 | 92563 | None | BBMPFIRE179 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fifth Floor) (Column) | Cum | 16389.34 | 16389.34 | 1.98 | False | None | None | False | None | False | 32450.8932 | 0 | 2852413 | 92563 | None | BBMPFIRE180 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fifth Floor) (Shear Wall) | Cum | 10604.87 | 10604.87 | 8.01 | False | None | None | False | None | False | 84945.0087 | 0 | 2852414 | 92563 | None | BBMPFIRE181 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fifth Floor) (Roof Beams) | Cum | 15425.26 | 15425.26 | 8.313 | False | None | None | False | None | False | 128230.18638 | 0 | 2852415 | 92563 | None | BBMPFIRE182 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fifth Floor) (Staircase) | Cum | 14461.18 | 14461.18 | 14.13 | False | None | None | False | None | False | 204336.4734 | 0 | 2852416 | 92563 | None | BBMPFIRE183 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fifth Floor) (Cill & Lintel) | Cum | 14595.33 | 14595.33 | 0.21 | False | None | None | False | None | False | 3065.0193 | 0 | 2852417 | 92563 | None | BBMPFIRE184 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Fifth Floor) (Chajja) | Cum | 13227.02 | 13227.02 | 0.9315 | False | None | None | False | None | False | 12320.96913 | 0 | 2852418 | 92563 | None | BBMPFIRE185 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Fifth Floor) | t | 123082.09 | 123082.09 | 5.68 | False | None | None | False | None | False | 699106.2712 | 0 | 2852419 | 92563 | None | BBMPFIRE186 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Fifth Floor) | Sqm | 1802.4 | 1802.4 | 40.35 | False | None | None | False | None | False | 72726.84 | 0 | 2852420 | 92563 | None | BBMPFIRE187 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Fifth Floor) | Sqm | 510.45 | 510.45 | 92.75 | False | None | None | False | None | False | 47344.2375 | 0 | 2852421 | 92563 | None | BBMPFIRE188 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Fifth Floor) | Sqm | 383.87 | 383.87 | 230.27 | False | None | None | False | None | False | 88393.7449 | 0 | 2852422 | 92563 | None | BBMPFIRE189 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including ounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Fifth Floor) | Sqm | 444.4 | 444.4 | 37.8 | False | None | None | False | None | False | 16798.32 | 0 | 2852423 | 92563 | None | BBMPFIRE190 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Fifth Floor) | Sqm | 9013.38 | 9013.38 | 4.86 | False | None | None | False | None | False | 43805.0268 | 0 | 2852424 | 92563 | None | BBMPFIRE191 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. (Fifth Floor) | Kgs | 251.78 | 251.78 | 102.06 | False | None | None | False | None | False | 25696.6668 | 0 | 2852425 | 92563 | None | BBMPFIRE192 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. (Fifth Floor) | Sqm | 3924.0 | 3924.0 | 38.23 | False | None | None | False | None | False | 150014.52 | 0 | 2852426 | 92563 | None | BBMPFIRE193 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of the slab upto 0.50 m2 (Fifth Floor) | Sqm | 5511.77 | 5511.77 | 4.57 | False | None | None | False | None | False | 25188.7889 | 0 | 2852427 | 92563 | None | BBMPFIRE194 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. (Fifth Floor) | m | 451.28 | 451.28 | 42.9 | False | None | None | False | None | False | 19359.912 | 0 | 2852428 | 92563 | None | BBMPFIRE195 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fifth Floor) | Sqm | 239.4 | 239.4 | 92.75 | False | None | None | False | None | False | 22204.35 | 0 | 2852429 | 92563 | None | BBMPFIRE196 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Painting) (Fifth Floor) | Sqm | 137.58 | 137.58 | 230.27 | False | None | None | False | None | False | 31680.5466 | 0 | 2852430 | 92563 | None | BBMPFIRE197 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fifth Floor) | Sqm | 72.92 | 72.92 | 230.27 | False | None | None | False | None | False | 16791.2884 | 0 | 2852431 | 92563 | None | BBMPFIRE198 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fifth Floor) | Sqm | 174.73 | 174.73 | 230.27 | False | None | None | False | None | False | 40235.0771 | 0 | 2852432 | 92563 | None | BBMPFIRE199 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Fifth Floor) | Sqm | 191.24 | 191.24 | 141.822 | False | None | None | False | None | False | 27122.03928 | 0 | 2852433 | 92563 | None | BBMPFIRE200 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Fifth Floor) | Kgs | 777.37 | 777.37 | 108.0 | False | None | None | False | None | False | 83955.96 | 0 | 2852434 | 92563 | None | BBMPFIRE201 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Fifth Floor) | Cum | 116.94 | 116.94 | 4.2 | False | None | None | False | None | False | 491.148 | 0 | 2852435 | 92563 | None | BBMPFIRE202 | Chipping unsound weak concrete material from slabs. Beams, columns & roofs upto 50mm by manual means or by standard power driven percussion type including cleaning reinforcement with wire brush complete as per direction of Engineer incharge of work. (Sixth Floor) | Sqm | 199.99 | 199.99 | 5.625 | False | None | None | False | None | False | 1124.94375 | 0 | 2852436 | 92563 | None | BBMPFIRE203 | Making the opening in brick masonry for door/window/clerestory window including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping Sixth, all complete as per direction of Engineer-in-Charge. (Sixth Floor) | Sqm | 1439.17 | 1439.17 | 3.675 | False | None | None | False | None | False | 5288.94975 | 0 | 2852437 | 92563 | None | BBMPFIRE204 | Providing and fixing in position 12mm thick bitumen impregnated fiber board conforming to IS: 1838, including cost of primer, sealing compound Grade-A in expansion joints. (Sixth Floor) | Sqm | 761.09 | 761.09 | 39.0 | False | None | None | False | None | False | 29682.51 | 0 | 2852438 | 92563 | None | BBMPFIRE205 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Sixth Floor) | Sqm | 8496.0 | 8496.0 | 6.3 | False | None | None | False | None | False | 53524.8 | 0 | 2852439 | 92563 | None | BBMPFIRE206 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Sixth Floor) (Column) | Cum | 16543.96 | 16543.96 | 0.72 | False | None | None | False | None | False | 11911.6512 | 0 | 2852440 | 92563 | None | BBMPFIRE207 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Sixth Floor) (Shear Wall) | Cum | 10704.91 | 10704.91 | 5.301 | False | None | None | False | None | False | 56746.72791 | 0 | 2852441 | 92563 | None | BBMPFIRE208 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Sixth Floor) (Roof Slab) | Cum | 14597.61 | 14597.61 | 1.45 | False | None | None | False | None | False | 21166.5345 | 0 | 2852442 | 92563 | None | BBMPFIRE209 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Sixth Floor) (Coping Concrete) | Cum | 14733.02 | 14733.02 | 0.296 | False | None | None | False | None | False | 4360.97392 | 0 | 2852443 | 92563 | None | BBMPFIRE210 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (Sixth Floor) | t | 124243.24 | 124243.24 | 1.462 | False | None | None | False | None | False | 181643.61688 | 0 | 2852444 | 92563 | None | BBMPFIRE211 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 8" Block (Sixth Floor) | Sqm | 1819.4 | 1819.4 | 16.68 | False | None | None | False | None | False | 30347.592 | 0 | 2852445 | 92563 | None | BBMPFIRE212 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (Sixth Floor) | Sqm | 515.26 | 515.26 | 67.45 | False | None | None | False | None | False | 34754.287 | 0 | 2852446 | 92563 | None | BBMPFIRE213 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (Sixth Floor) | Sqm | 387.49 | 387.49 | 21.014 | False | None | None | False | None | False | 8142.71486 | 0 | 2852447 | 92563 | None | BBMPFIRE214 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including ounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Sixth Floor) | Sqm | 444.4 | 444.4 | 9.67 | False | None | None | False | None | False | 4297.348 | 0 | 2852448 | 92563 | None | BBMPFIRE215 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge (Sixth Floor) | Kgs | 188.88 | 188.88 | 464.0 | False | None | None | False | None | False | 87640.32 | 0 | 2852449 | 92563 | None | BBMPFIRE216 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Sixth Floor) | Sqm | 241.66 | 241.66 | 67.45 | False | None | None | False | None | False | 16299.967 | 0 | 2852450 | 92563 | None | BBMPFIRE217 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal Wall + Ceiling Painting) (Sixth Floor) | Sqm | 138.88 | 138.88 | 30.6875 | False | None | None | False | None | False | 4261.88 | 0 | 2852451 | 92563 | None | BBMPFIRE218 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Sixth Floor) | Sqm | 73.6 | 73.6 | 30.6875 | False | None | None | False | None | False | 2258.6 | 0 | 2852452 | 92563 | None | BBMPFIRE219 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Sixth Floor) | Sqm | 176.38 | 176.38 | 30.6875 | False | None | None | False | None | False | 5412.66125 | 0 | 2852453 | 92563 | None | BBMPFIRE220 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Sixth Floor) | Sqm | 193.05 | 193.05 | 138.46 | False | None | None | False | None | False | 26729.703 | 0 | 2852454 | 92563 | None | BBMPFIRE221 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Sixth Floor) | Sqm | 6219.31 | 6219.31 | 108.0 | False | None | None | False | None | False | 671685.48 | 0 | 2852455 | 92563 | None | BBMPFIRE222 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work. (Sixth Floor) | Cum | 118.05 | 118.05 | 5.625 | False | None | None | False | None | False | 664.03125 | 0 | 2852456 | 92563 | None | BBMPFIRE223 | Polyurethane based Single Component for New Surface: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Sixth Floor) | Sqm | 1134.69 | 1134.69 | 48.68 | False | None | None | False | None | False | 55236.7092 | 0 | 2852457 | 92563 | None | BBMPFIRE224 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification. (Stilt Floor) | Sqm | 1209.73 | 1209.73 | 36.0 | False | None | None | False | None | False | 43550.28 | 0 | 2852458 | 92563 | None | BBMPFIRE225 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Stilt Floor) | Kgs | 188.88 | 188.88 | 9943.07 | False | None | None | False | None | False | 1878047.0616 | 0 | 2852459 | 92563 | None | BBMPFIRE226 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Ground Floor) | Kgs | 178.29 | 178.29 | 14625.21 | False | None | None | False | None | False | 2607528.6909 | 0 | 2852460 | 92563 | None | BBMPFIRE227 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (First Floor) | Kgs | 180.05 | 180.05 | 14625.21 | False | None | None | False | None | False | 2633269.0605 | 0 | 2852461 | 92563 | None | BBMPFIRE228 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Second Floor) | Kgs | 181.82 | 181.82 | 14625.21 | False | None | None | False | None | False | 2659155.6822 | 0 | 2852462 | 92563 | None | BBMPFIRE229 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Third Floor) | Kgs | 183.58 | 183.58 | 14625.21 | False | None | None | False | None | False | 2684896.0518 | 0 | 2852463 | 92563 | None | BBMPFIRE230 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Fourth Floor) | Kgs | 185.35 | 185.35 | 14625.21 | False | None | None | False | None | False | 2710782.6735 | 0 | 2852464 | 92563 | None | BBMPFIRE231 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Fifth Floor) | Kgs | 187.11 | 187.11 | 14625.21 | False | None | None | False | None | False | 2736523.0431 | 0 | 2852465 | 92563 | None | BBMPFIRE232 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Sixth Floor) | Kgs | 188.88 | 188.88 | 17288.48 | False | None | None | False | None | False | 3265448.1024 | 0 | 2852466 | 92563 | None | BBMPFIRE233 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² (Sixth Floor) | Sqm | 1220.8 | 1220.8 | 30.0 | False | None | None | False | None | False | 36624.0 | 0 | 2852467 | 92563 | None | BBMPFIRE234 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) (Sixth Floor) | m | 1491.63 | 1491.63 | 12.0 | False | None | None | False | None | False | 17899.56 | 0 | 2852468 | 92563 | None | BBMPFIRE235 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge. (Terrace Floor) | Kgs | 190.65 | 190.65 | 4260.795 | False | None | None | False | None | False | 812320.56675 | 0 | 2852469 | 92563 | None | BBMPFIRE236 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (Terrace Floor) | Sqm | 194.85 | 194.85 | 73.78 | False | None | None | False | None | False | 14376.033 | 0 | 2852470 | 92563 | None | BBMPFIRE237 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² (Terrace Floor) | Sqm | 1232.21 | 1232.21 | 73.78 | False | None | None | False | None | False | 90912.4538 | 0 | 2852471 | 92563 | None | BBMPFIRE238 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) (Terrace Floor) | m | 1505.57 | 1505.57 | 10.85 | False | None | None | False | None | False | 16335.4345 | 0 | 2852472 | 92563 | None | BBMPFIRE239 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter (Terrace Floor) | m | 407.93 | 407.93 | 316.79 | False | None | None | False | None | False | 129228.1447 | 0 | 2852473 | 92563 | None | BBMPFIRE240 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Lintel) | Cum | 14211.54 | 14211.54 | 3.906 | False | None | None | False | None | False | 55510.27524 | 0 | 2852474 | 92563 | None | BBMPFIRE241 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including ounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Stilt Floor) | Each | 419.25 | 419.25 | 26.149 | False | None | None | False | None | False | 10962.96825 | 0 | 2852475 | 92563 | None | BBMPFIRE242 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 ce ment : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge. (Stilt Floor) | Sqm | 1038.39 | 1038.39 | 26.149 | False | None | None | False | None | False | 27152.86011 | 0 | 2852476 | 92563 | None | BBMPFIRE243 | Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick.complete including cost of materials, labour, usage charges of machinerycomplete as per specifications. (Stilt Floor) | Each | 2466.2 | 2466.2 | 2.0 | False | None | None | False | None | False | 4932.4 | 0 | 2852477 | 92563 | None | BBMPFIRE244 | Double Leaf doorset - Insulated Fire rated doorset (FD 120) - Staircase / exit pathway application / Refuge area. Providing and fixing of ISI marked fire doors as per IS 3614:2021, 120 minutes fire rating with 30 minutes insulation double leaf doorset tested to IS/ISO 3008. Doorset shall include grooved step frame profile of 125x75mm, made of 1.2mm GI (120GSM) and 60mm thick shutter made of 1.2mm GI (120GSM) with infill of 120kg density mineral wool. Grooved frame shall include EPDM smoke seal. Include hardwares, minimum 6nos SS ball bearing hinges of SS304 100x89x3mm, 1no of Single point Panic device and external trim with key cylinder on active leaf and 1no two point Panic device on the inactive leaf, tested as per EN1125 and CE marked. 2no of Door closer with spring size of EN 3-5, as per EN1154 and CE marked. 1no door coordinator for sequencing. 2nos vision panel 200 x 300 with 6mm clear fire rated glass and finished in desired colour of powder coating not less than 50microns including suitable anchors & fire rated puff grouting all inclusive for fixing of doorset - for staircase / exit pathway / Refuge area applications. (Stilt Floor) | Sqm | 8496.0 | 8496.0 | 3.15 | False | None | None | False | None | False | 26762.4 | 0 | 2852478 | 92563 | None | BBMPFIRE245 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. Depth 3 m to 6 m (Stilt Floor) | Cum | 151.86 | 151.86 | 19.14 | False | None | None | False | None | False | 2906.6004 | 0 | 2852479 | 92563 | None | BBMPFIRE246 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. (Stilt Floor) | Cum | 7773.72 | 7773.72 | 11.484 | False | None | None | False | None | False | 89273.40048 | 0 | 2852480 | 92563 | None | BBMPFIRE247 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cm in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (Stilt Floor) | Cum | 207.67 | 207.67 | 32.4 | False | None | None | False | None | False | 6728.508 | 0 | 2852481 | 92563 | None | BBMPFIRE248 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Sump Bottom Slab) | Cum | 12336.19 | 12336.19 | 21.03 | False | None | None | False | None | False | 259430.0757 | 0 | 2852482 | 92563 | None | BBMPFIRE249 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Sump Vertical Wall) | Cum | 9046.54 | 9046.54 | 30.528 | False | None | None | False | None | False | 276172.77312 | 0 | 2852483 | 92563 | None | BBMPFIRE250 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Stilt Floor) (Sump Top Slab) | Cum | 12336.19 | 12336.19 | 27.936 | False | None | None | False | None | False | 344623.80384 | 0 | 2852484 | 92563 | None | BBMPFIRE251 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. (Stilt Floor) | Each | 2546.67 | 2546.67 | 2.0 | False | None | None | False | None | False | 5093.34 | 0 | 2852485 | 92563 | None | BBMPFIRE252 | Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500% (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N/m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect self-adhesive polymer layer, etc, including surface preparation completely as per specification. (Stilt Floor) | Sqm | 785.29 | 785.29 | 278.4 | False | None | None | False | None | False | 218624.736 | 0 | 2852486 | 92563 | None | BBMPFIRE253 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (Terrace) | l | 12.49 | 12.49 | 20000.0 | False | None | None | False | None | False | 249800.0 | 0 | 2852487 | 92563 | None | BBMPFIRE254 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Stilt to Ground Floor) | m | 384.2 | 384.2 | 105.0 | False | None | None | False | None | False | 40341.0 | 0 | 2852488 | 92563 | None | BBMPFIRE255 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Ground to First Floor) | m | 388.05 | 388.05 | 4.0 | False | None | None | False | None | False | 1552.2 | 0 | 2852489 | 92563 | None | BBMPFIRE256 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (First to Second Floor) | m | 391.89 | 391.89 | 4.0 | False | None | None | False | None | False | 1567.56 | 0 | 2852490 | 92563 | None | BBMPFIRE257 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Second to Third Floor) | m | 395.73 | 395.73 | 4.0 | False | None | None | False | None | False | 1582.92 | 0 | 2852491 | 92563 | None | BBMPFIRE258 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Third to Fourth Floor) | m | 399.57 | 399.57 | 4.0 | False | None | None | False | None | False | 1598.28 | 0 | 2852492 | 92563 | None | BBMPFIRE259 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Fourth to Fifth Floor) | m | 403.41 | 403.41 | 4.0 | False | None | None | False | None | False | 1613.64 | 0 | 2852493 | 92563 | None | BBMPFIRE260 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Fifth to Sixth Floor) | m | 407.26 | 407.26 | 4.0 | False | None | None | False | None | False | 1629.04 | 0 | 2852494 | 92563 | None | BBMPFIRE261 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (Sixth to Terrace Floor) | m | 411.1 | 411.1 | 4.0 | False | None | None | False | None | False | 1644.4 | 0 | 2852495 | 92563 | None | BBMPFIRE262 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (Stilt Floor) | Nos. | 430.93 | 430.93 | 1.0 | False | None | None | False | None | False | 430.93 | 0 | 2852496 | 92563 | None | BBMPFIRE263 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (Terrace Floor) | Nos. | 465.41 | 465.41 | 1.0 | False | None | None | False | None | False | 465.41 | 0 | 2852497 | 92563 | None | BBMPFIRE264 | Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete. 25mm dia PVC couplers (Stilt to Terrace) | Each | 15.57 | 15.57 | 25.0 | False | None | None | False | None | False | 389.25 | 0 | 2852498 | 92563 | None | BBMPFIRE265 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 25mm dia PVC Tees (Stilt to Terrace) | Each | 27.25 | 27.25 | 25.0 | False | None | None | False | None | False | 681.25 | 0 | 2852499 | 92563 | None | BBMPFIRE266 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments. 25mm dia PVC Bend (Stilt to Terrace) | Each | 31.15 | 31.15 | 25.0 | False | None | None | False | None | False | 778.75 | 0 | 2852500 | 92563 | None | BBMPFIRE267 | Supply, installation, testing & commissioning of diesel engine driven pump,horizontal mounted, Horizontal spiltcase centrifugal single stage pump,capable of delivering required flow at required head when running at 1800 RPM with adequate BHP automatic diesel engine driven pumpset having the residential silencer system and other accessories like fuel tank, necessary radiator cooling system, flanges, neoprene gaskets (16.0 kg/sqcm), 200 litres fuel storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) common bed plate with anti vibration pads, necessary foundation, foundation bolts etc., Diesel Pump -2280 lpm at 90m head | Set | 713900.0 | 713900.0 | 1.0 | False | None | None | False | None | False | 713900.0 | 0 | 2852501 | 92563 | None | BBMPFIRE268 | Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering,adequate LPM at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440 V 3 phase, 50 cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary anti vibration pads, necessary foundation bolts and accessories,neoprine gaskets (16 kg/sq.cm) Control panel is excluded. Required GA drawing for the pump/ foundation shall be submitted by the contractor. 2280 lpm at 90m head | Set | 359900.0 | 359900.0 | 2.0 | False | None | None | False | None | False | 719800.0 | 0 | 2852502 | 92563 | None | BBMPFIRE269 | Supply, Installation, testing and commisioning electrically driven jockey pump of capacity 180.0 Lpm at required head end suction type bronze impeller pump oupled to electrical driven motor with suitable HP with all the necessary accessories, operating on 3Ph 50Hz, 400/440 V AC supply including foundation, foundation bolts, anti vibration pad,etc. complete. Including cost of materials, labour, usage charges of machinery complete as per specifications. Control panle is excluded. Required GA drawing for the pump/ foundation shall be submitted by the contractor. 180 lpm at 90m head | Set | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 | 2852503 | 92563 | None | BBMPFIRE270 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm. - 200mm dia | m | 5074.0 | 5074.0 | 12.0 | False | None | None | False | None | False | 60888.0 | 0 | 2852504 | 92563 | None | BBMPFIRE271 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-150mm dia | m | 4602.0 | 4602.0 | 30.0 | False | None | None | False | None | False | 138060.0 | 0 | 2852505 | 92563 | None | BBMPFIRE272 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-100mm dia | m | 3363.0 | 3363.0 | 12.0 | False | None | None | False | None | False | 40356.0 | 0 | 2852506 | 92563 | None | BBMPFIRE273 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-80mm dia | m | 2714.0 | 2714.0 | 12.0 | False | None | None | False | None | False | 32568.0 | 0 | 2852507 | 92563 | None | BBMPFIRE274 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-65mm dia | m | 2006.0 | 2006.0 | 18.0 | False | None | None | False | None | False | 36108.0 | 0 | 2852508 | 92563 | None | BBMPFIRE275 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-25 mm dia | m | 826.0 | 826.0 | 36.0 | False | None | None | False | None | False | 29736.0 | 0 | 2852509 | 92563 | None | BBMPFIRE276 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work -200mm Dia CI butterfly valves | Each | 18880.0 | 18880.0 | 1.0 | False | None | None | False | None | False | 18880.0 | 0 | 2852510 | 92563 | None | BBMPFIRE277 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work -150mm Dia CI butterfly valves | Each | 14750.0 | 14750.0 | 8.0 | False | None | None | False | None | False | 118000.0 | 0 | 2852511 | 92563 | None | BBMPFIRE278 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 100mm Dia CI butterfly valves | Each | 10620.0 | 10620.0 | 2.0 | False | None | None | False | None | False | 21240.0 | 0 | 2852512 | 92563 | None | BBMPFIRE279 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 80mm Dia CI butterfly valves | Each | 8260.0 | 8260.0 | 1.0 | False | None | None | False | None | False | 8260.0 | 0 | 2852513 | 92563 | None | BBMPFIRE280 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 65mm Dia CI butterfly valves | Each | 6490.0 | 6490.0 | 1.0 | False | None | None | False | None | False | 6490.0 | 0 | 2852514 | 92563 | None | BBMPFIRE281 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 50mm Dia CI butterfly valves | Each | 5310.0 | 5310.0 | 1.0 | False | None | None | False | None | False | 5310.0 | 0 | 2852515 | 92563 | None | BBMPFIRE282 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 150 mm Dia CI Non Return Valve | Each | 13570.0 | 13570.0 | 4.0 | False | None | None | False | None | False | 54280.0 | 0 | 2852516 | 92563 | None | BBMPFIRE283 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 100 mm Dia CI Non Return Valve | Each | 8401.6 | 8401.6 | 2.0 | False | None | None | False | None | False | 16803.2 | 0 | 2852517 | 92563 | None | BBMPFIRE284 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 80 mm Dia CI Non Return Valve | Each | 6490.0 | 6490.0 | 1.0 | False | None | None | False | None | False | 6490.0 | 0 | 2852518 | 92563 | None | BBMPFIRE285 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 65 mm Dia CI Non Return Valve | Each | 5133.0 | 5133.0 | 1.0 | False | None | None | False | None | False | 5133.0 | 0 | 2852519 | 92563 | None | BBMPFIRE286 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in charge of the work - 50 mm Dia CI Non Return Valve | Each | 3481.0 | 3481.0 | 1.0 | False | None | None | False | None | False | 3481.0 | 0 | 2852520 | 92563 | None | BBMPFIRE287 | Supply, Erection, Testing & commissioning of Foot Valves of Following Dimensions: 150 mm dia Including all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and convene of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer - in charge of this work. | Each | 11210.0 | 11210.0 | 3.0 | False | None | None | False | None | False | 33630.0 | 0 | 2852521 | 92563 | None | BBMPFIRE288 | Supply, Erection, Testing & commissioning of Foot Valves of Following Dimensions: 80 mm dia Including all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and convene of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer - in charge of this work. | Each | 4838.0 | 4838.0 | 1.0 | False | None | None | False | None | False | 4838.0 | 0 | 2852522 | 92563 | None | BBMPFIRE289 | Pressure Switch including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Each | 2301.0 | 2301.0 | 4.0 | False | None | None | False | None | False | 9204.0 | 0 | 2852523 | 92563 | None | BBMPFIRE290 | Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work | Each | 3422.0 | 3422.0 | 3.0 | False | None | None | False | None | False | 10266.0 | 0 | 2852524 | 92563 | None | BBMPFIRE291 | Supplying fixing and testing of Air cushions vessel. Fabricated out of 8mm thik It is a 250 mm dia MS pipes (the ends should be dished) 1.2 M high installed verically on suitable legs. Flange connection shall be provided for connection with wet riser pipe Cylinder connected with 25 mm dia gunmetal gate valves , pressure guage. The air vessel shall be tested at 25 Kg/cm2 at the bottom of the cylinder absorbs and water hammering blow in the pipe line. The price includes 25 mm dia connection MS pipes and supporting etc., complete ---- Including all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and convene of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer - in charge of this work. | Each | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 2852525 | 92563 | None | BBMPFIRE292 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete | Each | 1770.0 | 1770.0 | 2.0 | False | None | None | False | None | False | 3540.0 | 0 | 2852526 | 92563 | None | BBMPFIRE293 | Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 1416.0 | 1416.0 | 6.0 | False | None | None | False | None | False | 8496.0 | 0 | 2852527 | 92563 | None | BBMPFIRE294 | COPPER CONTROL CABLE : 4 C x 16 sq mm Aluminium armoured cable. | m | 660.8 | 660.8 | 30.0 | False | None | None | False | None | False | 19824.0 | 0 | 2852528 | 92563 | None | BBMPFIRE295 | 1.1 kV Class Armoured Aluminium Cable with glands / lugs / ferrules : 4C x 95 Sq mm | m | 899.16 | 899.16 | 30.0 | False | None | None | False | None | False | 26974.8 | 0 | 2852529 | 92563 | None | BBMPFIRE296 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 10C x 2.5 mm2 | m | 506.21 | 506.21 | 20.0 | False | None | None | False | None | False | 10124.2 | 0 | 2852530 | 92563 | None | BBMPFIRE297 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. - 2C x 1.5 mm2 | m | 62.54 | 62.54 | 60.0 | False | None | None | False | None | False | 3752.4 | 0 | 2852531 | 92563 | None | BBMPFIRE298 | CABLE TRAY: 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. 300 x 50 mm | m | 692.66 | 692.66 | 50.0 | False | None | None | False | None | False | 34633.0 | 0 | 2852532 | 92563 | None | BBMPFIRE299 | GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 3 mm GI strip | m | 96.75 | 96.75 | 50.0 | False | None | None | False | None | False | 4837.5 | 0 | 2852533 | 92563 | None | BBMPFIRE300 | Supply, erection, testing and commissioning of Fire Fighting panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted, degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners. The switchboards are to be tested as per IS 8623-1977 specifications. Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height Incoming feeder for 400A TPN MCCB with 400 Amps. TPN Al. Bus bars with color coded heat shrinkable PVC sleeves, RYB indicating lamps with individual MCB control. Suitable Mulit Fuction meter with CTs OUTGOING Feeder for 1 No. of main pumps :- 1 Nos.250A TP MCCB with 100 HP Star delta starter with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons. 1 No. Auto manual selector switch.Feeder for 1 No. of Jockey pump :- 1 No. 100A TP MCCB with 15 HP star delta starter with over load relay, single phase preventer and indicating lamps with ON / OFF push buttons. 1 No. Auto manual selector switch. Feeder for 1 No. DIESEL ENGINE MAIN PUMP :- a) 20Amps DP MCB - 4 Nos. b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 2 Nos. c) 1 set of indicating lamps for the following : 1. phase indication 2. battery charger on 3. over load relay 4. DC supply on 5. control switch on 6. Engine fails to start 7. Pump on 8. Low oil pressure 9. High water temperature 10. Auto manual selector switch d) 1 sets of push button stations for the following : 1. Engine Start 2. Engine Stop 3. Engine - hooter ACK 4. Engine - fault reset e) Selector switches (Engine control, mode selector)-1 No. f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine - 1 set. g) Hooter for audio alarm (Industrial type) - 1 No. | Each | 365800.0 | 365800.0 | 1.0 | False | None | None | False | None | False | 365800.0 | 0 | 2852534 | 92563 | None | BBMPFIRE301 | supply and installing testing and commissioning of CI " Y " stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 150 mm Dia CI " Y " stainer. | Each | 21889.0 | 21889.0 | 1.0 | False | None | None | False | None | False | 21889.0 | 0 | 2852535 | 92563 | None | BBMPFIRE302 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-150mm dia | m | 4602.0 | 4602.0 | 1362.0 | False | None | None | False | None | False | 6267924.0 | 0 | 2852536 | 92563 | None | BBMPFIRE303 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-100mm dia | m | 3363.0 | 3363.0 | 180.0 | False | None | None | False | None | False | 605340.0 | 0 | 2852537 | 92563 | None | BBMPFIRE304 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-80mm dia | m | 2714.0 | 2714.0 | 48.0 | False | None | None | False | None | False | 130272.0 | 0 | 2852538 | 92563 | None | BBMPFIRE305 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-25 mm dia | m | 826.0 | 826.0 | 18.0 | False | None | None | False | None | False | 14868.0 | 0 | 2852539 | 92563 | None | BBMPFIRE306 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 7670.0 | 7670.0 | 7.0 | False | None | None | False | None | False | 53690.0 | 0 | 2852540 | 92563 | None | BBMPFIRE307 | FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 12390.0 | 12390.0 | 33.0 | False | None | None | False | None | False | 408870.0 | 0 | 2852541 | 92563 | None | BBMPFIRE308 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 5900.0 | 5900.0 | 66.0 | False | None | None | False | None | False | 389400.0 | 0 | 2852542 | 92563 | None | BBMPFIRE309 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 5310.0 | 5310.0 | 33.0 | False | None | None | False | None | False | 175230.0 | 0 | 2852543 | 92563 | None | BBMPFIRE310 | Supplying Installing, testing and commissioning of Gun metal BALL VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 1416.0 | 1416.0 | 7.0 | False | None | None | False | None | False | 9912.0 | 0 | 2852544 | 92563 | None | BBMPFIRE311 | Supplying Installing, testing and commissioning of Hose reel cabin | Each | 6018.0 | 6018.0 | 7.0 | False | None | None | False | None | False | 42126.0 | 0 | 2852545 | 92563 | None | BBMPFIRE312 | Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 6136.0 | 6136.0 | 7.0 | False | None | None | False | None | False | 42952.0 | 0 | 2852546 | 92563 | None | BBMPFIRE313 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 7670.0 | 7670.0 | 26.0 | False | None | None | False | None | False | 199420.0 | 0 | 2852547 | 92563 | None | BBMPFIRE314 | Supplying Installing, testing and commissioning of 150mm dia 4 way Fire brigade inlet connection with Non retrn valve of 4 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 44840.0 | 44840.0 | 2.0 | False | None | None | False | None | False | 89680.0 | 0 | 2852548 | 92563 | None | BBMPFIRE315 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications | Each | 38940.0 | 38940.0 | 1.0 | False | None | None | False | None | False | 38940.0 | 0 | 2852549 | 92563 | None | BBMPFIRE316 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-incharge of the work-150mm dia CI butterfly valves | Each | 14750.0 | 14750.0 | 12.0 | False | None | None | False | None | False | 177000.0 | 0 | 2852550 | 92563 | None | BBMPFIRE317 | Supplying installing, testing and commissioning of PN16 CI "Non Return Valve " confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-150 mm Dia CI Non Return Valve | Each | 13570.0 | 13570.0 | 4.0 | False | None | None | False | None | False | 54280.0 | 0 | 2852551 | 92563 | None | BBMPFIRE318 | supply and installing testing and commissioning of CI " Y " stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-150 mm Dia CI " Y " stainer | Each | 21889.0 | 21889.0 | 1.0 | False | None | None | False | None | False | 21889.0 | 0 | 2852552 | 92563 | None | BBMPFIRE319 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. Complete | Each | 1770.0 | 1770.0 | 8.0 | False | None | None | False | None | False | 14160.0 | 0 | 2852553 | 92563 | None | BBMPFIRE320 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge | Kgs | 133.34 | 133.34 | 4000.0 | False | None | None | False | None | False | 533360.0 | 0 | 2852554 | 92563 | None | BBMPFIRE321 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.01 | 164.01 | 600.0 | False | None | None | False | None | False | 98406.0 | 0 | 2852555 | 92563 | None | BBMPFIRE322 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-150mm dia | m | 4602.0 | 4602.0 | 90.0 | False | None | None | False | None | False | 414180.0 | 0 | 2852556 | 92563 | None | BBMPFIRE323 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-100mm dia | m | 3363.0 | 3363.0 | 90.0 | False | None | None | False | None | False | 302670.0 | 0 | 2852557 | 92563 | None | BBMPFIRE324 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-80mm dia | m | 2714.0 | 2714.0 | 396.0 | False | None | None | False | None | False | 1074744.0 | 0 | 2852558 | 92563 | None | BBMPFIRE325 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-65mm dia | m | 2006.0 | 2006.0 | 190.0 | False | None | None | False | None | False | 381140.0 | 0 | 2852559 | 92563 | None | BBMPFIRE326 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-50 mm dia | m | 1534.0 | 1534.0 | 284.0 | False | None | None | False | None | False | 435656.0 | 0 | 2852560 | 92563 | None | BBMPFIRE327 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-40 mm dia | m | 1239.0 | 1239.0 | 270.0 | False | None | None | False | None | False | 334530.0 | 0 | 2852561 | 92563 | None | BBMPFIRE328 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-32 mm dia | m | 944.0 | 944.0 | 234.0 | False | None | None | False | None | False | 220896.0 | 0 | 2852562 | 92563 | None | BBMPFIRE329 | Providing and fabricating MS supports using channel, angle, plates pipes, etc., to take the load of number of pipes and the dia of the pipes as per specification and drawings. Rate quoted shall include for supply and providing necessary welding, cutting, G.I "U" clamps, bolt nuts, washers, anchors fastener etc., as per specification or pipe supports for horizontal / vertical pipes running along wall / column, slab trenches etc., to suit different dia pipes made of GI/MS rods, flats, etc., consists of strap, nuts washers, threaded rod etc., The rate quoted shall also include for giving one coat of zinc chromate primer and two coats of approved enamel paint for pipe supports. The pipe support shall be U type support using 50x50x6mm requires for supporting 80mm, 100mm and 150mm dia single pipe.The bracket inside the fire shaft shall be 100mm x50x5mm-25 mm dia | m | 826.0 | 826.0 | 1362.0 | False | None | None | False | None | False | 1125012.0 | 0 | 2852563 | 92563 | None | BBMPFIRE330 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-incharge of the work-150 mm dia CI butterfly valves | Each | 14750.0 | 14750.0 | 4.0 | False | None | None | False | None | False | 59000.0 | 0 | 2852564 | 92563 | None | BBMPFIRE331 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-incharge of the work-100 mm dia CI butterfly valves | Each | 10620.0 | 10620.0 | 8.0 | False | None | None | False | None | False | 84960.0 | 0 | 2852565 | 92563 | None | BBMPFIRE332 | Supplying, installing , testing and commissioning of PN16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-incharge of the work-50 mm dia CI butterfly valves | Each | 5310.0 | 5310.0 | 8.0 | False | None | None | False | None | False | 42480.0 | 0 | 2852566 | 92563 | None | BBMPFIRE333 | Supplying Installing, testing and commissioning of, pendent Type/Upright Type ,Standard Response Standard Coverage, Sprinkler, K5.6(80),1/2”NPT, 68 Degree C, Chrome finish, UL listed. | Each | 442.5 | 442.5 | 680.0 | False | None | None | False | None | False | 300900.0 | 0 | 2852567 | 92563 | None | BBMPFIRE334 | Supplying Installing of Horizantal side wall Type ,Standard Response Standard Coverage, Sprinkler, K5.6(80),1/2”NPT, 68 Degree C, Chrome finish, UL listed. | Each | 413.0 | 413.0 | 16.0 | False | None | None | False | None | False | 6608.0 | 0 | 2852568 | 92563 | None | BBMPFIRE335 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 129.79 | 129.79 | 644.0 | False | None | None | False | None | False | 83584.76 | 0 | 2852569 | 92563 | None | BBMPFIRE336 | Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1000 mm long 25 mm dia with union / reducer collar, clamps etc. as required. | Each | 2242.0 | 2242.0 | 644.0 | False | None | None | False | None | False | 1443848.0 | 0 | 2852570 | 92563 | None | BBMPFIRE337 | Supplying Installing, testing and commissioning of hydraulically operated sprinkler Gong Valve with water meter gong bell and trims as required, pressure gauges drain Valve, ball Valves check valve, strainer etc. including cost of materials, labour, usage charges of machinery complete as per specifications.150 mm dia. complete | m | 82600.0 | 82600.0 | 1.0 | False | None | None | False | None | False | 82600.0 | 0 | 2852571 | 92563 | None | BBMPFIRE338 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge | Kgs | 133.34 | 133.34 | 1000.0 | False | None | None | False | None | False | 133340.0 | 0 | 2852572 | 92563 | None | BBMPFIRE339 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.01 | 164.01 | 200.0 | False | None | None | False | None | False | 32802.0 | 0 | 2852573 | 92563 | None | BBMPFIRE340 | Supply, installation of 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM, Discharge Time less than 13 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8, C and electrically started Fire, A Rating 2A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with installation system with Superior quality EPDM Rubber Hosepipe etc., including cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, , labour, usage charges of machinery complete as per specifications. complete IS 15683, CE Approved.-Providing ABC Powder based MAP 50, 4Kg | Each | 3127.0 | 3127.0 | 24.0 | False | None | None | False | None | False | 75048.0 | 0 | 2852574 | 92563 | None | BBMPFIRE341 | Providing 6kg SPM-TEC Powder Based stored presure type melting point at 600-650 degree C, Applicable on Class D metal fires in Magnesium, Aluminium, Zinc, Sodium Potassium, Francium, Lithium, Cesium, Pressure Guage, Gross weight Gross Weight 9.4Kg, empty weight 3.4 Kg, Can Height 480 MM, Diameter 160 M M, Discharge Time less than 16 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, Can construction : Deep drawn & Co. , Mig welded, valve Construciton CE Approved : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60 M M, 5 years warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete-Providing 6 Kg Fire Extinguisher for Lite metal fires SPM-TEC | Each | 9558.0 | 9558.0 | 1.0 | False | None | None | False | None | False | 9558.0 | 0 | 2852575 | 92563 | None | BBMPFIRE342 | Supply and installation of 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete-C02 2Kg Squeeze grip | Each | 6490.0 | 6490.0 | 12.0 | False | None | None | False | None | False | 77880.0 | 0 | 2852576 | 92563 | None | BBMPFIRE343 | Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete-C02 4.5Kg Squeeze grip | Each | 7670.0 | 7670.0 | 4.0 | False | None | None | False | None | False | 30680.0 | 0 | 2852577 | 92563 | None | BBMPFIRE344 | Supplying of four bucket stand alongwith buckets. Complete | Each | 2183.0 | 2183.0 | 12.0 | False | None | None | False | None | False | 26196.0 | 0 | 2852578 | 92563 | None | BBMPFIRE345 | Supplying of Hand gloves. complete | Each | 1150.5 | 1150.5 | 20.0 | False | None | None | False | None | False | 23010.0 | 0 | 2852579 | 92563 | None | BBMPFIRE346 | Supplying of first aid box. complete | Each | 708.0 | 708.0 | 20.0 | False | None | None | False | None | False | 14160.0 | 0 | 2852580 | 92563 | None | BBMPFIRE347 | Supplying of SAFETY MASK. complete | Each | 177.0 | 177.0 | 20.0 | False | None | None | False | None | False | 3540.0 | 0 | 2852581 | 92563 | None | BBMPFIRE348 | Supplying of FIRST AID CHART with lamination. Complete | Each | 472.0 | 472.0 | 20.0 | False | None | None | False | None | False | 9440.0 | 0 | 2852582 | 92563 | None | BBMPFIRE349 | Supply and installation of 9 Ltr Water type Fire Extinugisher, Stored Pressure Type, Pressur Gauge, Gross Weight 15.1kg. empty weight 6.1kg Can Height 615MM, Diameter 175 MM, Discharge Time less than 120 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A Fire, A Rating 3A, Can Construction; Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness: 2.OM M, lS 15683 and CE Approved. Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete-Providing Water type- 9 Ltr -Stored Pressure | Each | 10738.0 | 10738.0 | 16.0 | False | None | None | False | None | False | 171808.0 | 0 | 2852583 | 92563 | None | BBMPFIRE350 | Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, ocmplete with mirror fasteners. Providing and installing in position the following Signage printed with "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.25cm height letters in red with white back ground. The size of the board shall be 25cm x 25cm and shall be fixed at the height of 2mts. From finished floor near Manual Call Point. | Each | 802.4 | 802.4 | 12.0 | False | None | None | False | None | False | 9628.8 | 0 | 2852584 | 92563 | None | BBMPFIRE351 | Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, ocmplete with mirror fasteners. Providing and installing in position the following Floor indentification signage GROUND FLOOR TO 6TH FLOOR. at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 5cm with contrasting colour from back ground. Size shall be 15cm x 30 cm. | Each | 802.4 | 802.4 | 12.0 | False | None | None | False | None | False | 9628.8 | 0 | 2852585 | 92563 | None | BBMPFIRE352 | Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, ocmplete with mirror fasteners. Providing and installing in position the following Exit sinage FIRE EXIT at each stair enclosure on every floor, indicating the direction of exit, lettering size shall be 7.5 cm with contrasting colour from back ground. Size shall be 15cm x 60cm. | Each | 802.4 | 802.4 | 12.0 | False | None | None | False | None | False | 9628.8 | 0 | 2852586 | 92563 | None | BBMPFIRE353 | Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, ocmplete with mirror fasteners. Assembly area signage at Stilt floor, indicating the location of assembly in case of fire emergency, lettering size shall be 12.5 cm with contrasting colour from back ground. Size shall be 30cm x 45cm.Supply & Installation. | Each | 802.4 | 802.4 | 1.0 | False | None | None | False | None | False | 802.4 | 0 | 2852587 | 92563 | None | BBMPFIRE354 | Providing and Fixing Fire force board size of 3'x2' made out to Acrylic sheet of 3mm thick and fixing with Stainless Steel finished studs etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. 1. ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.
2. EVACUATE THE OCCUPANTS BY USING FIRE EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POINTS.
3. IF POSSIBBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUTIBLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WETRISER.
4. BE CALM AND DO NOT GIVE ANY ROOM FOR PANIC, WALK, DO NOT RUN.
5. IFYOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, SHOUT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. 1. ACTION BY SECURITY / RECEPTION UPON RECEPTION OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.
2. ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM.
3. SEND INFORMATION toFIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS:
4. REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE.
5. GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE PLACE OF FIRE.
6. IN CASE OF THE CASUALTIES, ON THEIR ARRIVAL TO THE PLACE OF FIRE.
7. FIRE FIGHTING AGENCY…………
8. PHONE……………..
9. FIRE PROTECTION ENGINEERS FAX……………………………………. | m | 2950.0 | 2950.0 | 25.0 | False | None | None | False | None | False | 73750.0 | 0 | 2852588 | 92563 | None | BBMPFIRE355 | Supplying Installation testing and Commissiong of Micro process base Fire alram Control panel having power regulation Circuit, which conner to 230 AC to @V.D.C. Indicating FIRE-FAULT, Test facility also with work test facility arrangement, provided in the panel. All this electronic circuits componets are assembled in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking arrangements including cost of all mateials etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications-48 Zone. | Each | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 2852589 | 92563 | None | BBMPFIRE356 | P.A.System amplifier 250W RM S out put with complete wiring and controls accessable form front | Each | 41595.0 | 41595.0 | 1.0 | False | None | None | False | None | False | 41595.0 | 0 | 2852590 | 92563 | None | BBMPFIRE357 | Supplying Installing, testing and commissioning of MIKE suitable to I.A.System. Complete | Each | 6490.0 | 6490.0 | 1.0 | False | None | None | False | None | False | 6490.0 | 0 | 2852591 | 92563 | None | BBMPFIRE358 | Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. | Each | 1770.0 | 1770.0 | 12.0 | False | None | None | False | None | False | 21240.0 | 0 | 2852592 | 92563 | None | BBMPFIRE359 | Supplying Installing, testing and commissioning of electronic Hooter, it conists of electronic circuit to give dual Fire alaram sound with works. 24V DC with speaker all encased in suitable in MS 16 gauge red painted box. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 1770.0 | 1770.0 | 12.0 | False | None | None | False | None | False | 21240.0 | 0 | 2852593 | 92563 | None | BBMPFIRE360 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 6 W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 2891.0 | 2891.0 | 12.0 | False | None | None | False | None | False | 34692.0 | 0 | 2852594 | 92563 | None | BBMPFIRE361 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting including cost of materials, labour, usage charges of machinery complete as per specifications | Each | 95580.0 | 95580.0 | 1.0 | False | None | None | False | None | False | 95580.0 | 0 | 2852595 | 92563 | None | BBMPFIRE362 | Supply Installation testing & Commissioning of conventional type photo/Heat electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20C to +60C. IP Rating at IP 23D & Approval with EN- 54 -7, LPCB Approved. | Each | 2478.0 | 2478.0 | 384.0 | False | None | None | False | None | False | 951552.0 | 0 | 2852596 | 92563 | None | BBMPFIRE363 | Supplying Installing, testing and commissioning of electronic Hooter, it conists of electronic circuit to give dual Fire alaram sound with works. 24V DC with speaker all encased in suitable in MS 16 gauge red painted box. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 1770.0 | 1770.0 | 6.0 | False | None | None | False | None | False | 10620.0 | 0 | 2852597 | 92563 | None | BBMPFIRE364 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary | m | 77.88 | 77.88 | 3500.0 | False | None | None | False | None | False | 272580.0 | 0 | 2852598 | 92563 | None | BBMPFIRE365 | Supplying and drawing of 2 Core X 1.5 Sqmm copper conductor armoured cable | Each | 177.0 | 177.0 | 6500.0 | False | None | None | False | None | False | 1150500.0 | 0 | 2852599 | 92563 | None | BBMPFIRE366 | Point Wiring using copper wire without switch: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Short point upto 3Mtr from tapping point to out let via switch box | Point | 317.41 | 317.41 | 2.0 | False | None | None | False | None | False | 634.82 | 0 | 2852600 | 92563 | None | BBMPFIRE367 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Long point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 654.9 | 654.9 | 3.0 | False | None | None | False | None | False | 1964.7 | 0 | 2852601 | 92563 | None | BBMPFIRE368 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 4.0 | False | None | None | False | None | False | 3195.44 | 0 | 2852602 | 92563 | None | BBMPFIRE369 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 8.0 | False | None | None | False | None | False | 9336.16 | 0 | 2852603 | 92563 | None | BBMPFIRE370 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-1 -2Way | Each | 162.84 | 162.84 | 5.0 | False | None | None | False | None | False | 814.2 | 0 | 2852604 | 92563 | None | BBMPFIRE371 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-3 Way | Each | 187.61 | 187.61 | 5.0 | False | None | None | False | None | False | 938.05 | 0 | 2852605 | 92563 | None | BBMPFIRE372 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-4 Way | Each | 208.85 | 208.85 | 1.0 | False | None | None | False | None | False | 208.85 | 0 | 2852606 | 92563 | None | BBMPFIRE373 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-6 Way | Each | 259.59 | 259.59 | 2.0 | False | None | None | False | None | False | 519.18 | 0 | 2852607 | 92563 | None | BBMPFIRE374 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-8 Way | Each | 307.97 | 307.97 | 1.0 | False | None | None | False | None | False | 307.97 | 0 | 2852608 | 92563 | None | BBMPFIRE375 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-10 / 12 Way | Each | 376.41 | 376.41 | 1.0 | False | None | None | False | None | False | 376.41 | 0 | 2852609 | 92563 | None | BBMPFIRE376 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-1 - 2 Module | Each | 161.66 | 161.66 | 5.0 | False | None | None | False | None | False | 808.3 | 0 | 2852610 | 92563 | None | BBMPFIRE377 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-3 Module | Each | 189.98 | 189.98 | 5.0 | False | None | None | False | None | False | 949.9 | 0 | 2852611 | 92563 | None | BBMPFIRE378 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-4 - 5 Module | Each | 206.5 | 206.5 | 1.0 | False | None | None | False | None | False | 206.5 | 0 | 2852612 | 92563 | None | BBMPFIRE379 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6 Module | Each | 276.12 | 276.12 | 2.0 | False | None | None | False | None | False | 552.24 | 0 | 2852613 | 92563 | None | BBMPFIRE380 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-8 Module | Each | 335.12 | 335.12 | 1.0 | False | None | None | False | None | False | 335.12 | 0 | 2852614 | 92563 | None | BBMPFIRE381 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-10 / 12 Module | Each | 405.91 | 405.91 | 1.0 | False | None | None | False | None | False | 405.91 | 0 | 2852615 | 92563 | None | BBMPFIRE382 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A One Way Switch | Each | 120.36 | 120.36 | 10.0 | False | None | None | False | None | False | 1203.6 | 0 | 2852616 | 92563 | None | BBMPFIRE383 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A Two Way Switch | Each | 195.88 | 195.88 | 1.0 | False | None | None | False | None | False | 195.88 | 0 | 2852617 | 92563 | None | BBMPFIRE384 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A Three Way socket | Each | 201.78 | 201.78 | 5.0 | False | None | None | False | None | False | 1008.9 | 0 | 2852618 | 92563 | None | BBMPFIRE385 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-16A One Way Switch | Each | 212.39 | 212.39 | 5.0 | False | None | None | False | None | False | 1061.95 | 0 | 2852619 | 92563 | None | BBMPFIRE386 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-32A DP Switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 2852620 | 92563 | None | BBMPFIRE387 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6/16A Universal Socket | Each | 278.47 | 278.47 | 5.0 | False | None | None | False | None | False | 1392.35 | 0 | 2852621 | 92563 | None | BBMPFIRE388 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary - 20 mm dia 2 mm thick | m | 77.88 | 77.88 | 50.0 | False | None | None | False | None | False | 3894.0 | 0 | 2852622 | 92563 | None | BBMPFIRE389 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.-25 mm dia 2 mm thick | m | 92.03 | 92.03 | 125.0 | False | None | None | False | None | False | 11503.75 | 0 | 2852623 | 92563 | None | BBMPFIRE390 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.-32 mm dia 2.5 mm thick | m | 121.53 | 121.53 | 25.0 | False | None | None | False | None | False | 3038.25 | 0 | 2852624 | 92563 | None | BBMPFIRE391 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-20 mm dia 2 mm thick | m | 80.24 | 80.24 | 50.0 | False | None | None | False | None | False | 4012.0 | 0 | 2852625 | 92563 | None | BBMPFIRE392 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-25 mm dia 2 mm thick | m | 93.22 | 93.22 | 125.0 | False | None | None | False | None | False | 11652.5 | 0 | 2852626 | 92563 | None | BBMPFIRE393 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-32 mm dia 2.5 mm thick | m | 116.82 | 116.82 | 25.0 | False | None | None | False | None | False | 2920.5 | 0 | 2852627 | 92563 | None | BBMPFIRE394 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-1 mm2 | m | 22.41 | 22.41 | 200.0 | False | None | None | False | None | False | 4482.0 | 0 | 2852628 | 92563 | None | BBMPFIRE395 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-1 .5 mm2 | m | 30.68 | 30.68 | 500.0 | False | None | None | False | None | False | 15340.0 | 0 | 2852629 | 92563 | None | BBMPFIRE396 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-2.5 mm2 | m | 49.55 | 49.55 | 300.0 | False | None | None | False | None | False | 14865.0 | 0 | 2852630 | 92563 | None | BBMPFIRE397 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-4 mm2 | m | 74.33 | 74.33 | 100.0 | False | None | None | False | None | False | 7433.0 | 0 | 2852631 | 92563 | None | BBMPFIRE398 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-6 mm2 | m | 108.55 | 108.55 | 100.0 | False | None | None | False | None | False | 10855.0 | 0 | 2852632 | 92563 | None | BBMPFIRE399 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.-II - Double Door - 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 2852633 | 92563 | None | BBMPFIRE400 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.-III - Double Door - 4 Way TP & N | Each | 4764.84 | 4764.84 | 1.0 | False | None | None | False | None | False | 4764.84 | 0 | 2852634 | 92563 | None | BBMPFIRE401 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-6-32 A SP | Each | 489.7 | 489.7 | 10.0 | False | None | None | False | None | False | 4897.0 | 0 | 2852635 | 92563 | None | BBMPFIRE402 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-6-32 A DP | Each | 872.02 | 872.02 | 1.0 | False | None | None | False | None | False | 872.02 | 0 | 2852636 | 92563 | None | BBMPFIRE403 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-40 A DP | Each | 1250.8 | 1250.8 | 1.0 | False | None | None | False | None | False | 1250.8 | 0 | 2852637 | 92563 | None | BBMPFIRE404 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.-32-40A 2 pole | Each | 5379.62 | 5379.62 | 1.0 | False | None | None | False | None | False | 5379.62 | 0 | 2852638 | 92563 | None | BBMPFIRE405 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 36/40 W | Each | 1497.41 | 1497.41 | 10.0 | False | None | None | False | None | False | 14974.1 | 0 | 2852639 | 92563 | None | BBMPFIRE406 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition-LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 6.0 | False | None | None | False | None | False | 6265.8 | 0 | 2852640 | 92563 | None | BBMPFIRE407 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition-LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 1.0 | False | None | None | False | None | False | 1562.32 | 0 | 2852641 | 92563 | None | BBMPFIRE408 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.-400 mm Sweep | Each | 3790.16 | 3790.16 | 6.0 | False | None | None | False | None | False | 22740.96 | 0 | 2852642 | 92563 | None | BBMPFIRE409 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 201.78 | 201.78 | 15.0 | False | None | None | False | None | False | 3026.7 | 0 | 2852643 | 92563 | None | BBMPFIRE410 | Fixing of Wall/ ceiling fan of all capacities and all types to the existing hook together with supplying and fixing a 5 A ceiling rose , necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring complete | Each | 371.7 | 371.7 | 15.0 | False | None | None | False | None | False | 5575.5 | 0 | 2852644 | 92563 | None | BBMPFIRE411 | Air circulators of 48" dia and 40'.0" air throw,the air circulator shall be fixed with necessary angle iron bracket and other fixing accessories. | Each | 13570.0 | 13570.0 | 4.0 | False | None | None | False | None | False | 54280.0 | 0 | 2852645 | 92563 | None | BBMPFIRE412 | Design, supplying, erecting testing and commissioning of - Passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. B.With Machine Room-SS Finish - 20 Passengers 8 Stops.
Note: For more than 6 stops, lift with speed of 1.5 mtr / sec. is recommended. To arrive the rates for 1.5 mtr/sec. speed lifts add 10% on the above rates. | Job | 4701772.13 | 4701772.13 | 1.0 | False | None | None | False | None | False | 4701772.13 | 0 | 2852646 | 92563 | None | BBMPFIRE413 | Point Wiring using copper wire without switch: Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Short point upto 3Mtr from tapping point to out let via switch box | Point | 317.41 | 317.41 | 5.0 | False | None | None | False | None | False | 1587.05 | 0 | 2852647 | 92563 | None | BBMPFIRE414 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Long point above 6 mts upto 10 mts from tapping point to outlet via switch | Point | 654.9 | 654.9 | 3.0 | False | None | None | False | None | False | 1964.7 | 0 | 2852648 | 92563 | None | BBMPFIRE415 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 798.86 | 798.86 | 4.0 | False | None | None | False | None | False | 3195.44 | 0 | 2852649 | 92563 | None | BBMPFIRE416 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.-Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1167.02 | 1167.02 | 7.0 | False | None | None | False | None | False | 8169.14 | 0 | 2852650 | 92563 | None | BBMPFIRE417 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-1 -2Way | Each | 162.84 | 162.84 | 6.0 | False | None | None | False | None | False | 977.04 | 0 | 2852651 | 92563 | None | BBMPFIRE418 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-3 Way | Each | 187.61 | 187.61 | 4.0 | False | None | None | False | None | False | 750.44 | 0 | 2852652 | 92563 | None | BBMPFIRE419 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-4 Way | Each | 208.85 | 208.85 | 2.0 | False | None | None | False | None | False | 417.7 | 0 | 2852653 | 92563 | None | BBMPFIRE420 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-6 Way | Each | 259.59 | 259.59 | 2.0 | False | None | None | False | None | False | 519.18 | 0 | 2852654 | 92563 | None | BBMPFIRE421 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-8 Way | Each | 307.97 | 307.97 | 1.0 | False | None | None | False | None | False | 307.97 | 0 | 2852655 | 92563 | None | BBMPFIRE422 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-10 / 12 Way | Each | 376.41 | 376.41 | 1.0 | False | None | None | False | None | False | 376.41 | 0 | 2852656 | 92563 | None | BBMPFIRE423 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-1 - 2 Module | Each | 161.66 | 161.66 | 6.0 | False | None | None | False | None | False | 969.96 | 0 | 2852657 | 92563 | None | BBMPFIRE424 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-3 Module | Each | 189.98 | 189.98 | 4.0 | False | None | None | False | None | False | 759.92 | 0 | 2852658 | 92563 | None | BBMPFIRE425 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-4 - 5 Module | Each | 206.5 | 206.5 | 2.0 | False | None | None | False | None | False | 413.0 | 0 | 2852659 | 92563 | None | BBMPFIRE426 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-6 Module | Each | 276.12 | 276.12 | 2.0 | False | None | None | False | None | False | 552.24 | 0 | 2852660 | 92563 | None | BBMPFIRE427 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-8 Module | Each | 335.12 | 335.12 | 1.0 | False | None | None | False | None | False | 335.12 | 0 | 2852661 | 92563 | None | BBMPFIRE428 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.-10 / 12 Module | Each | 405.91 | 405.91 | 1.0 | False | None | None | False | None | False | 405.91 | 0 | 2852662 | 92563 | None | BBMPFIRE429 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A One Way Switch | Each | 120.36 | 120.36 | 11.0 | False | None | None | False | None | False | 1323.96 | 0 | 2852663 | 92563 | None | BBMPFIRE430 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A Three Way socket | Each | 201.78 | 201.78 | 5.0 | False | None | None | False | None | False | 1008.9 | 0 | 2852664 | 92563 | None | BBMPFIRE431 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-16A One Way Switch | Each | 212.39 | 212.39 | 5.0 | False | None | None | False | None | False | 1061.95 | 0 | 2852665 | 92563 | None | BBMPFIRE432 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-32A DP Switch | Each | 384.68 | 384.68 | 1.0 | False | None | None | False | None | False | 384.68 | 0 | 2852666 | 92563 | None | BBMPFIRE433 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6/16A Universal Socket | Each | 278.47 | 278.47 | 5.0 | False | None | None | False | None | False | 1392.35 | 0 | 2852667 | 92563 | None | BBMPFIRE434 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thickconfirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case ofRCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.-20 mm dia 2 mm thick | m | 81.42 | 81.42 | 50.0 | False | None | None | False | None | False | 4071.0 | 0 | 2852668 | 92563 | None | BBMPFIRE435 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.-25 mm dia 2 mm thick | m | 95.58 | 95.58 | 125.0 | False | None | None | False | None | False | 11947.5 | 0 | 2852669 | 92563 | None | BBMPFIRE436 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.-32 mm dia 2.5 mm thick | m | 125.08 | 125.08 | 25.0 | False | None | None | False | None | False | 3127.0 | 0 | 2852670 | 92563 | None | BBMPFIRE437 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-1 mm2 | m | 22.41 | 22.41 | 250.0 | False | None | None | False | None | False | 5602.5 | 0 | 2852671 | 92563 | None | BBMPFIRE438 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-1 .5 mm2 | m | 30.68 | 30.68 | 500.0 | False | None | None | False | None | False | 15340.0 | 0 | 2852672 | 92563 | None | BBMPFIRE439 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-2.5 mm2 | m | 49.55 | 49.55 | 300.0 | False | None | None | False | None | False | 14865.0 | 0 | 2852673 | 92563 | None | BBMPFIRE440 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-4 mm2 | m | 74.33 | 74.33 | 100.0 | False | None | None | False | None | False | 7433.0 | 0 | 2852674 | 92563 | None | BBMPFIRE441 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010-6 mm2 | m | 108.55 | 108.55 | 75.0 | False | None | None | False | None | False | 8141.25 | 0 | 2852675 | 92563 | None | BBMPFIRE442 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.-II - Double Door - 12 Way SP & N | Each | 2748.22 | 2748.22 | 1.0 | False | None | None | False | None | False | 2748.22 | 0 | 2852676 | 92563 | None | BBMPFIRE443 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door - 4 Way TP & N | Each | 4764.84 | 4764.84 | 1.0 | False | None | None | False | None | False | 4764.84 | 0 | 2852677 | 92563 | None | BBMPFIRE444 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-6-32 A SP | Each | 489.7 | 489.7 | 10.0 | False | None | None | False | None | False | 4897.0 | 0 | 2852678 | 92563 | None | BBMPFIRE445 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-6-32 A DP | Each | 872.02 | 872.02 | 1.0 | False | None | None | False | None | False | 872.02 | 0 | 2852679 | 92563 | None | BBMPFIRE446 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.- 40 A DP | Each | 1250.8 | 1250.8 | 1.0 | False | None | None | False | None | False | 1250.8 | 0 | 2852680 | 92563 | None | BBMPFIRE447 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.-32-40A 2 pole | Each | 5379.62 | 5379.62 | 1.0 | False | None | None | False | None | False | 5379.62 | 0 | 2852681 | 92563 | None | BBMPFIRE448 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.-LED light fitting 1 x 4' - 36/40 W | Each | 1497.41 | 1497.41 | 10.0 | False | None | None | False | None | False | 14974.1 | 0 | 2852682 | 92563 | None | BBMPFIRE449 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition-LED square or round down light 10-12W | Each | 1044.3 | 1044.3 | 6.0 | False | None | None | False | None | False | 6265.8 | 0 | 2852683 | 92563 | None | BBMPFIRE450 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition-LED square or round down light 15-18W | Each | 1562.32 | 1562.32 | 2.0 | False | None | None | False | None | False | 3124.64 | 0 | 2852684 | 92563 | None | BBMPFIRE451 | Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. | Each | 993.56 | 993.56 | 4.0 | False | None | None | False | None | False | 3974.24 | 0 | 2852685 | 92563 | None | BBMPFIRE452 | Supplying & fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-8-9 W | Each | 735.14 | 735.14 | 4.0 | False | None | None | False | None | False | 2940.56 | 0 | 2852686 | 92563 | None | BBMPFIRE453 | Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.-400 mm Sweep | Each | 3790.16 | 3790.16 | 3.0 | False | None | None | False | None | False | 11370.48 | 0 | 2852687 | 92563 | None | BBMPFIRE454 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders | Each | 143.95 | 143.95 | 15.0 | False | None | None | False | None | False | 2159.25 | 0 | 2852688 | 92563 | None | BBMPFIRE455 | Fixing of Wall/ ceiling fan of all capacities and all types to the existing hook together with supplying and fixing a 5 A ceiling rose , necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring complete | Each | 371.7 | 371.7 | 15.0 | False | None | None | False | None | False | 5575.5 | 0 | 2852689 | 92563 | None | BBMPFIRE456 | Air circulators of 48" dia and 40'.0" air throw,the air circulator shall be fixed with necessary angle iron bracket and other fixing accessories. | Each | 13570.0 | 13570.0 | 4.0 | False | None | None | False | None | False | 54280.0 | 0 | 2852690 | 92563 | None | BBMPFIRE457 | Utility shifting charges | Each | 1593000.0 | 1593000.0 | 1.0 | False | None | None | False | None | False | 1593000.0 | 0 |
|