createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709642998523
version14
createdDateNone
modifiedDateNone
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
tenderFee5000.00
emd307700.00
bidValueTypeLUMPSUM
bidValueTypeTextLumpsum
techWeightage75
tenderReceiptClose14-03-2024 17:00:00
tenderQueryClose07-03-2024 16:00:00
technicalBidOpen15-03-2024 17:01:00
publishedDate06-03-2024 20:22:20
publishedByPostCNNL_EE_DIV_HCI_HEB
publishedByUserKPE18270 - KOPPAL SHIVAPPA KIRAN
bidValidityPeriod90
noOfCalls1
preBidMeetingDate11-03-2024 16:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
retenderedYnNone
contactPersonKOPPAL SHIVAPPA KIRAN
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageFalse
isMultipleSupplierSelectionAllowedNone
techEvalStartDateNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
qcbsTenderYnTrue
itemwiseEmdRequiredYnNone
itemwiseTechEvalYnNone
officeNumber08162957008
mobileNumber9591356664
provisionalAmount24230000.0
tenderSupplierListNone
tenderSchedule
createdTs1709642998553
version6
createdDateNone
modifiedDateNone
tenderNumberCNNL/2023-24/SE0081
titleProject management consultantancy (PMC)for Inspection, testing, quality control and monitoring and construction supervision for Construction of Intake arrangement, Cross regulator, Gravity main MS etc. for Ensuring water supply to Sriranga tank filling scheme by providing gravity pipe line starting from ch-70.00 Km of TBC for Drinking water needs to Magadi & Kunigal taluk under Hemavathy Project. (Phase-I).
descriptionProject management consultantancy (PMC)for Inspection, testing, quality control and monitoring and construction supervision for Construction of Intake arrangement, Cross regulator, Gravity main MS etc. for Ensuring water supply to Sriranga tank filling scheme by providing gravity pipe line starting from ch-70.00 Km of TBC for Drinking water needs to Magadi & Kunigal taluk under Hemavathy Project. (Phase-I).
categorySERVICES
categoryTextServices
ecv20511020.02
deptNameCauvery Neeravari Nigam Limited
fileNameNone
statusPUBLISHED
statusTextPublished
remarksNone
ecvtenderYnTrue
location5725
locationNameCNNL HCI Div Hebbur
procEntityTypeTextNone
tenderGroups
createdTsversioncreatedDatemodifiedDategroupNameitemListitemSize
17096429985540NoneNoneDefault
createdTsversioncreatedDatemodifiedDateitemCodeitemNamevalueOfServiceextendOfContractquantityspecificationsbiddingUnitestimateUnitRateestimateItemPricedenominationTypeitemEmd
17096429990000NoneNoneWRDSRV-IV_P-24_I-15HELPER LABORATORYNone730.03.0MEASUREMENT/BILLING/DESIGN/SERVICES:HELPER LABORATORY as directed by engineer incharge of work DAILY499.431093751.70RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1WField surveyour / Total station operatorNone24.03.0MEASUREMENT/BILLING/DESIGN/SERVICES:Field surveyour / Total station operator (Engineering Graduate Employee) as directed by engineer incharge of work MONTHLY28978.362086441.92RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1RLAB TECHNICIANSNone24.04.0MEASUREMENT/BILLING/DESIGN/SERVICES:LAB TECHNICIANS (Engineering Graduate Employee) as directed by engineer incharge of work MONTHLY28978.362781922.56RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1FFIELD ENGINEERSNone24.05.0MEASUREMENT/BILLING/DESIGN/SERVICES:FIELD ENGINEERS (Diploma in Engineering Employee) as directed by engineer incharge of work MONTHLY23313.362797603.20RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1APROJECT MANAGER FOR PMCNone24.01.0QUALITY CERTIFICATION CONFIRMITY TO DESIGN AND SPECIFICATION OF WORKS EXECUTED BY CONSTRUCTION AGENCY BY QUALIFIED ENGINEERS:MEASUREMENT/BILLING/SERVICES-PROJECT MANAGER (Engineering Graduate Employee). as directed by engineer incharge of work MONTHLY28978.36695480.64RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21eSwelling Pressure testNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Swelling pressure test as directed by engineer incharge of work PER UNIT800.0136000.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21DTraxial sheara at OMCNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Triaxial shear at saturation as directed by engineer incharge of work PER UNIT1860.0316200.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21CPERMIABILITY AT OMCNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Permeability at OMC as directed by engineer incharge of work PER UNIT975.0165750.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21BTraxial shear at OMC insitu conditionNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Traxial shear at OMC insitu condition as directed by engineer incharge of work PER UNIT1860.0316200.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21AStandard compaction testNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Standard compaction test OMC MDD as directed by engineer incharge of work PER UNIT400.068000.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21SPECIFIC GRAVITYNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Specific gravity as directed by engineer incharge of work PER UNIT270.045900.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-120_I-21Consolidation testNone500.01.0SOIL MECHANICS:SOIL MECHANICS - Consolidation test as directed by engineer incharge of work PER UNIT805.0402500.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6eConducting compression testNone1484.01.0CEMENT:CEMENT - Conducting compression test on cement concrete cubes as directed by engineer incharge of work PER UNIT415.0615860.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6dSetting TestNone1484.01.0CEMENT:CEMENT - Setting time initial & final setting timeas directed by engineer incharge of work PER UNIT360.0534240.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6cSoundness TestNone1484.01.0CEMENT:CEMENT - Fineness test as directed by engineer incharge of work PER UNIT220.0326480.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6aFineness testNone1484.01.0CEMENT:CEMENT - Fineness test as directed by engineer incharge of work PER UNIT150.0222600.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6Consistency TestNone1484.01.0CEMENT:CEMENT - Consistency test as directed by engineer incharge of work PER UNIT220.0326480.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2eSilt contentNone186.01.0SAND:SAND -Silt content as directed by engineer incharge of work PER UNIT190.035340.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2cfineness modulusNone186.01.0SAND:SAND-FINENESS MODULUS PER UNIT190.035340.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2BSpecific gravity, bulk density, bulking moixture content and water absorptionNone186.01.0SAND:SAND - Specific gravity, bulk density, bulking & moixture content and water absorption as directed by engineer incharge of work PER UNIT480.089280.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2AParticle finer than 75 micronNone186.01.0SAND:SAND - Particle finer than 75 micron as directed by engineer incharge of work PER UNIT210.039060.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2SIEVE ANALYSISNone186.01.0SAND:SAND - Sieve analysis as directed by engineer incharge of work PER UNIT210.039060.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1XSTRIPPING VALUENone406.01.0coarse aggregates:COARSE AGGREGATE - Stripping Value as directed by engineer incharge of work PER UNIT190.077140.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1QTEN PERCENT FINE VALUENone406.01.0coarse aggregates:COARSE AGGREGATE - 10% fine value as directed by engineer incharge of work PER UNIT460.0186760.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1GAbrasion Value Of Coarse aggregatesNone406.01.0coarse aggregates:COARSE AGGREGATE - Abrasion Value as directed by engineer incharge of work PER UNIT460.0186760.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1eCrushing ValueNone406.01.0coarse aggregates:COARSE AGGREGATE - Crushing Value as directed by engineer incharge of work PER UNIT460.0186760.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1CAggregate Impact OF COARSE AGGREGTENone406.01.0coarse aggregates:COARSE AGGREGATE - Aggregate Impact value as directed by engineer incharge of work PER UNIT360.0146160.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1BSpecific gravity, bulk density FOR COARSE AGGREGATENone406.01.0coarse aggregates:COARSE AGGREGATE - Specific gravity, bulk density as directed by engineer incharge of work PER UNIT480.0194880.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1AAsieve analysis OF COARSENone406.01.0coarse aggregates:COARSE AGGREGATE - Sieve analysis as directed by engineer incharge of work PER UNIT190.077140.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1Particle finer than 75 micron FOR COARSE AGGREGATESNone406.01.0coarse aggregates:COARSE AGGREGATE - Particle finer than 75 micron as directed by engineer incharge of work PER UNIT190.077140.00RUPEESNone
17096429990000NoneNonePWDV-I_P-120_I-18eConducting lab test on steel f Dia nore than 20mmNone50.01.0STEEL:Conducting test on steel determining tensile strength, elongation, 0.2% proof stress and unit weight of Dia nore than 20mm as directed by engineer PER UNIT700.035000.00RUPEESNone
17096429990000NoneNonePWDV-I_P-120_I-18Conducting lab test on steel upto 20mm diaNone50.01.0STEEL:Conducting test on steel round for tensile strength, elongation, 0.2% proof stress and unit weight of up to 20mm dia as directed by engineer incharge PER UNIT650.032500.00RUPEESNone
17096429990000NoneNonePWDV-I_P-120_I-16Conducting non-destructing testNone895.01.0NON DESTRUCTIVE TEST:Conducting non-destructing test using rebound hammer at site (including conveyance and incidental charges) as directed by engineer incharge of work PER UNIT300.0268500.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-8WConcrete core extraction testNone60.01.0CEMENT CONCRETE:Concrete core extraction test Extraction and Conducting Compression test of core samples including and furnishing the reports. (3 cores) Up to 100mm PER UNIT1300.078000.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-8ASLUMP TESTNone6782.01.0CEMENT CONCRETE:Slump test as directed by engineer incharge of work PER UNIT250.01695500.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-8Concrete, cube compression testNone4752.01.0CEMENT CONCRETE:Concrete, cube compression test Casting and testing for compressive strength of Cubes by normal curing method as directed by engineer incharge of work PER UNIT415.01972080.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4YImpact Value OF BITUMINOUS CONCRETE OR MIXNone154.01.0BITUMINIOUS CONCRETE:Impact Value as directed by engineer incharge of work PER UNIT360.055440.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4WAbrasion Value OF BITUMINOUS CONCRETE OR MIXNone154.01.0BITUMINIOUS CONCRETE:brasion Value as directed by engineer incharge of work PER UNIT460.070840.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4RFLAKINESS AND ELONGATION,WATER ABSORPTION,DENSITYNone154.01.0BITUMINIOUS CONCRETE:Flakines& Elongation ,Water Absorption and Density as directed by engineer incharge PER UNIT480.073920.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4Sieve Analysis OF BITUMINOUS CONCRETE OR MIXNone154.01.0BITUMINIOUS CONCRETE:Sieve Analysis as directed by engineer incharge of work PER UNIT190.029260.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3YSOFTENING POINTNone154.01.0BITUMEN:Softening point test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3QDuctilityNone154.01.0BITUMEN:Ductility as directed by engineer incharge of work PER UNIT605.093170.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3DFlash and Fire point testNone154.01.0BITUMEN:Flash and Fire point test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3ASpecific gravity testNone154.01.0BITUMEN:Specific gravity test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3Penetration testNone154.01.0BITUMEN:Penetration test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDSR_V-I_P-121_I-26SIEVE ANALYSIS OF WET MIX MACADAMNone167.01.0WETY MIX MACADAM:Sieve Analysis as directed by engineer incharge of work PER UNIT575.096025.00RUPEESNone
17096429990000NoneNonePWDSR_V-I_P-120_I-16Ultrasonic pulse velocity testNone709.01.0TEST ON PIPES:Ultrasonic pulse velocity test as directed by engineer incharge of work PER UNIT450.0319050.00RUPEESNone
17096429990000NoneNonePWDSR_V-I_P-120_I-13Sieve Analysis OF GRANULAR SUB BASENone167.01.0GRANULAR SUB BASE:Sieve Analysis as directed by engineer incharge of work PER UNIT575.096025.00RUPEESNone
17096429990000NoneNonePWD23-24_V-I_P-120_I-21Mechanical analysisNone170.01.0Mechanical Analysis:SOIL MECHANICS -Mechanical analysis (Sieve test) as directed by engineer incharge of work PER UNIT335.056950.00RUPEESNone
17096429990000NoneNonePWD2023-24_V-I_P-120_I-21Liqid limit and plastic limit testNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Liqid limit and plastic limit test as directed by engineer incharge of worK PER UNIT605.0102850.00RUPEESNone
17096429990000NoneNoneMARKET_RATE001Test on pipe shell thicknessNone709.01.0TEST ON PIPES:Test on pipe shell thickness as directed by engineer incharge of work NUMBER125.088625.00RUPEESNone
17096429990000NoneNoneMARKETRATE_003Test On guniting Thickness Of M.S PipeNone709.01.0TEST ON PIPES:Test On guniting Thickness Of M.S Pipe as directed by engineer incharge of work NUMBER125.088625.00RUPEESNone
17096429990000NoneNoneMARKETRATE_002Test On Paint ThicknessNone709.01.0TEST ON PIPES:Test On Paint Thickness Of M.S Pipe as directed by engineer incharge of work NUMBER150.0106350.00RUPEESNone
17096429990000NoneNoneKERSSR_P-6_I-91Bitumin content testNone154.01.0BITUMINIOUS CONCRETE:Bitumin content test as directed by engineer incharge of work PER UNIT3560.0548240.00RUPEESNone
54
generalCriterionListNone
preQualCriterionListNone
technicalCriterionListNone
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate & Balance sheets with UDIN from 2018-19 to 2022-23TrueTechnical Bid
Bidder should be KPWD registered AgencyTrueTechnical Bid
EPF Registration CertificateTrueTechnical Bid
GST Registration CertificateTrueTechnical Bid
Income tax returns for preceeding 5 years 2018-19 to 2022-23TrueTechnical Bid
tenderItemsList
createdTsversioncreatedDatemodifiedDateitemCodeitemNamevalueOfServiceextendOfContractquantityspecificationsbiddingUnitestimateUnitRateestimateItemPricedenominationTypeitemEmd
17096429990000NoneNoneKERSSR_P-6_I-91Bitumin content testNone154.01.0BITUMINIOUS CONCRETE:Bitumin content test as directed by engineer incharge of work PER UNIT3560.0548240.00RUPEESNone
17096429990000NoneNoneMARKETRATE_002Test On Paint ThicknessNone709.01.0TEST ON PIPES:Test On Paint Thickness Of M.S Pipe as directed by engineer incharge of work NUMBER150.0106350.00RUPEESNone
17096429990000NoneNoneMARKETRATE_003Test On guniting Thickness Of M.S PipeNone709.01.0TEST ON PIPES:Test On guniting Thickness Of M.S Pipe as directed by engineer incharge of work NUMBER125.088625.00RUPEESNone
17096429990000NoneNoneMARKET_RATE001Test on pipe shell thicknessNone709.01.0TEST ON PIPES:Test on pipe shell thickness as directed by engineer incharge of work NUMBER125.088625.00RUPEESNone
17096429990000NoneNonePWD2023-24_V-I_P-120_I-21Liqid limit and plastic limit testNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Liqid limit and plastic limit test as directed by engineer incharge of worK PER UNIT605.0102850.00RUPEESNone
17096429990000NoneNonePWD23-24_V-I_P-120_I-21Mechanical analysisNone170.01.0Mechanical Analysis:SOIL MECHANICS -Mechanical analysis (Sieve test) as directed by engineer incharge of work PER UNIT335.056950.00RUPEESNone
17096429990000NoneNonePWDSR_V-I_P-120_I-13Sieve Analysis OF GRANULAR SUB BASENone167.01.0GRANULAR SUB BASE:Sieve Analysis as directed by engineer incharge of work PER UNIT575.096025.00RUPEESNone
17096429990000NoneNonePWDSR_V-I_P-120_I-16Ultrasonic pulse velocity testNone709.01.0TEST ON PIPES:Ultrasonic pulse velocity test as directed by engineer incharge of work PER UNIT450.0319050.00RUPEESNone
17096429990000NoneNonePWDSR_V-I_P-121_I-26SIEVE ANALYSIS OF WET MIX MACADAMNone167.01.0WETY MIX MACADAM:Sieve Analysis as directed by engineer incharge of work PER UNIT575.096025.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3Penetration testNone154.01.0BITUMEN:Penetration test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3ASpecific gravity testNone154.01.0BITUMEN:Specific gravity test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3DFlash and Fire point testNone154.01.0BITUMEN:Flash and Fire point test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3QDuctilityNone154.01.0BITUMEN:Ductility as directed by engineer incharge of work PER UNIT605.093170.00RUPEESNone
17096429990000NoneNonePWDV-I_P-118_I-3YSOFTENING POINTNone154.01.0BITUMEN:Softening point test as directed by engineer incharge of work PER UNIT490.075460.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4Sieve Analysis OF BITUMINOUS CONCRETE OR MIXNone154.01.0BITUMINIOUS CONCRETE:Sieve Analysis as directed by engineer incharge of work PER UNIT190.029260.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4RFLAKINESS AND ELONGATION,WATER ABSORPTION,DENSITYNone154.01.0BITUMINIOUS CONCRETE:Flakines& Elongation ,Water Absorption and Density as directed by engineer incharge PER UNIT480.073920.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4WAbrasion Value OF BITUMINOUS CONCRETE OR MIXNone154.01.0BITUMINIOUS CONCRETE:brasion Value as directed by engineer incharge of work PER UNIT460.070840.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-4YImpact Value OF BITUMINOUS CONCRETE OR MIXNone154.01.0BITUMINIOUS CONCRETE:Impact Value as directed by engineer incharge of work PER UNIT360.055440.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-8Concrete, cube compression testNone4752.01.0CEMENT CONCRETE:Concrete, cube compression test Casting and testing for compressive strength of Cubes by normal curing method as directed by engineer incharge of work PER UNIT415.01972080.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-8ASLUMP TESTNone6782.01.0CEMENT CONCRETE:Slump test as directed by engineer incharge of work PER UNIT250.01695500.00RUPEESNone
17096429990000NoneNonePWDV-I_P-119_I-8WConcrete core extraction testNone60.01.0CEMENT CONCRETE:Concrete core extraction test Extraction and Conducting Compression test of core samples including and furnishing the reports. (3 cores) Up to 100mm PER UNIT1300.078000.00RUPEESNone
17096429990000NoneNonePWDV-I_P-120_I-16Conducting non-destructing testNone895.01.0NON DESTRUCTIVE TEST:Conducting non-destructing test using rebound hammer at site (including conveyance and incidental charges) as directed by engineer incharge of work PER UNIT300.0268500.00RUPEESNone
17096429990000NoneNonePWDV-I_P-120_I-18Conducting lab test on steel upto 20mm diaNone50.01.0STEEL:Conducting test on steel round for tensile strength, elongation, 0.2% proof stress and unit weight of up to 20mm dia as directed by engineer incharge PER UNIT650.032500.00RUPEESNone
17096429990000NoneNonePWDV-I_P-120_I-18eConducting lab test on steel f Dia nore than 20mmNone50.01.0STEEL:Conducting test on steel determining tensile strength, elongation, 0.2% proof stress and unit weight of Dia nore than 20mm as directed by engineer PER UNIT700.035000.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1Particle finer than 75 micron FOR COARSE AGGREGATESNone406.01.0coarse aggregates:COARSE AGGREGATE - Particle finer than 75 micron as directed by engineer incharge of work PER UNIT190.077140.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1AAsieve analysis OF COARSENone406.01.0coarse aggregates:COARSE AGGREGATE - Sieve analysis as directed by engineer incharge of work PER UNIT190.077140.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1BSpecific gravity, bulk density FOR COARSE AGGREGATENone406.01.0coarse aggregates:COARSE AGGREGATE - Specific gravity, bulk density as directed by engineer incharge of work PER UNIT480.0194880.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1CAggregate Impact OF COARSE AGGREGTENone406.01.0coarse aggregates:COARSE AGGREGATE - Aggregate Impact value as directed by engineer incharge of work PER UNIT360.0146160.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1eCrushing ValueNone406.01.0coarse aggregates:COARSE AGGREGATE - Crushing Value as directed by engineer incharge of work PER UNIT460.0186760.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1GAbrasion Value Of Coarse aggregatesNone406.01.0coarse aggregates:COARSE AGGREGATE - Abrasion Value as directed by engineer incharge of work PER UNIT460.0186760.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1QTEN PERCENT FINE VALUENone406.01.0coarse aggregates:COARSE AGGREGATE - 10% fine value as directed by engineer incharge of work PER UNIT460.0186760.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-1XSTRIPPING VALUENone406.01.0coarse aggregates:COARSE AGGREGATE - Stripping Value as directed by engineer incharge of work PER UNIT190.077140.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2SIEVE ANALYSISNone186.01.0SAND:SAND - Sieve analysis as directed by engineer incharge of work PER UNIT210.039060.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2AParticle finer than 75 micronNone186.01.0SAND:SAND - Particle finer than 75 micron as directed by engineer incharge of work PER UNIT210.039060.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2BSpecific gravity, bulk density, bulking moixture content and water absorptionNone186.01.0SAND:SAND - Specific gravity, bulk density, bulking & moixture content and water absorption as directed by engineer incharge of work PER UNIT480.089280.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2cfineness modulusNone186.01.0SAND:SAND-FINENESS MODULUS PER UNIT190.035340.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-118_I-2eSilt contentNone186.01.0SAND:SAND -Silt content as directed by engineer incharge of work PER UNIT190.035340.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6Consistency TestNone1484.01.0CEMENT:CEMENT - Consistency test as directed by engineer incharge of work PER UNIT220.0326480.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6aFineness testNone1484.01.0CEMENT:CEMENT - Fineness test as directed by engineer incharge of work PER UNIT150.0222600.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6cSoundness TestNone1484.01.0CEMENT:CEMENT - Fineness test as directed by engineer incharge of work PER UNIT220.0326480.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6dSetting TestNone1484.01.0CEMENT:CEMENT - Setting time initial & final setting timeas directed by engineer incharge of work PER UNIT360.0534240.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-119_I-6eConducting compression testNone1484.01.0CEMENT:CEMENT - Conducting compression test on cement concrete cubes as directed by engineer incharge of work PER UNIT415.0615860.00RUPEESNone
17096429990000NoneNonePWD_V-I_P-120_I-21Consolidation testNone500.01.0SOIL MECHANICS:SOIL MECHANICS - Consolidation test as directed by engineer incharge of work PER UNIT805.0402500.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21SPECIFIC GRAVITYNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Specific gravity as directed by engineer incharge of work PER UNIT270.045900.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21AStandard compaction testNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Standard compaction test OMC MDD as directed by engineer incharge of work PER UNIT400.068000.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21BTraxial shear at OMC insitu conditionNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Traxial shear at OMC insitu condition as directed by engineer incharge of work PER UNIT1860.0316200.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21CPERMIABILITY AT OMCNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Permeability at OMC as directed by engineer incharge of work PER UNIT975.0165750.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21DTraxial sheara at OMCNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Triaxial shear at saturation as directed by engineer incharge of work PER UNIT1860.0316200.00RUPEESNone
17096429990000NoneNoneV-I_P-120_I-21eSwelling Pressure testNone170.01.0SOIL MECHANICS:SOIL MECHANICS - Swelling pressure test as directed by engineer incharge of work PER UNIT800.0136000.00RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1APROJECT MANAGER FOR PMCNone24.01.0QUALITY CERTIFICATION CONFIRMITY TO DESIGN AND SPECIFICATION OF WORKS EXECUTED BY CONSTRUCTION AGENCY BY QUALIFIED ENGINEERS:MEASUREMENT/BILLING/SERVICES-PROJECT MANAGER (Engineering Graduate Employee). as directed by engineer incharge of work MONTHLY28978.36695480.64RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1FFIELD ENGINEERSNone24.05.0MEASUREMENT/BILLING/DESIGN/SERVICES:FIELD ENGINEERS (Diploma in Engineering Employee) as directed by engineer incharge of work MONTHLY23313.362797603.20RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1RLAB TECHNICIANSNone24.04.0MEASUREMENT/BILLING/DESIGN/SERVICES:LAB TECHNICIANS (Engineering Graduate Employee) as directed by engineer incharge of work MONTHLY28978.362781922.56RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-23_I-1WField surveyour / Total station operatorNone24.03.0MEASUREMENT/BILLING/DESIGN/SERVICES:Field surveyour / Total station operator (Engineering Graduate Employee) as directed by engineer incharge of work MONTHLY28978.362086441.92RUPEESNone
17096429990000NoneNoneWRDSRV-IV_P-24_I-15HELPER LABORATORYNone730.03.0MEASUREMENT/BILLING/DESIGN/SERVICES:HELPER LABORATORY as directed by engineer incharge of work DAILY499.431093751.70RUPEESNone
tenderEligibilityCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17096429990000NoneNoneELIGIBILITY Bidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17096430630002NoneNoneELIGIBILITYBidder should be KPWD registered AgencyNone
17096430730000NoneNoneELIGIBILITYTendering by the joint venture will not be permitted.None
17096430840000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17096430970000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17096431130000NoneNoneELIGIBILITYThe TENDER PROCEESING FEE will not be refunded.None
17096431440000NoneNoneELIGIBILITYThe requisite Earnest Money Deposit (EMD) through e-cash only Each tenderer must pay specified full Earnest money Deposit (EMD) in the eproc platform only through any of the payment modes such as Credit Card/ Debit Card/ NEFT / OTCNone
17096431580000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing Karnataka public procurement Portal.None
17096431740000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer will verify the original documents at any stage before recommending for approval. Bidders should produce their original documents for verification during office hours related to uploaded documents in Karnataka public procurement portal immediately after opening of technical Bid.None
17096431860000NoneNoneELIGIBILITYTenderers shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by the Government of Karnataka.None
17096431960000NoneNoneELIGIBILITYThe scanned signature of the bidders / authorized representatives of the bidders shall be attached while uploading the Bid document.None
17096432110000NoneNoneELIGIBILITYNecessary certificates should be signed by an officer not below the rank of the Executive Engineer or equivalent competent authority and should be countersigned by the superior officer not below the rank of Superintending Engineer or equivalent competent authority.None
17096432220000NoneNoneELIGIBILITYThe intending Bidder/firm/company should furnish list of man power available with him for taking up above work.None
17096432340000NoneNoneELIGIBILITYTenderer should furnish a copy of the Income Tax Return for the preceding five financial year (2018-19 to 2022-23)None
17096432590000NoneNoneELIGIBILITYThe intending Bidder/firm/company shall provide the audited balance sheets or other financial statements acceptable to the employer for the last five years (2018-19 to 2022-23) and must demonstrate the current soundness of the applicants financial position and indicate its prospective long term profitability. If deemed necessary the employer shall have the authority to make enquiries with the applicants bankers.None
17096432720000NoneNoneELIGIBILITYThe Tenderer should furnish a valid copy of GST Registration Certificate along with updated GST clearance copiesNone
17096433030000NoneNoneELIGIBILITYEmployees provident fund registration certificate along with copy of recent paid challan is to be furnished(i) Employees Provident fund Registration Certificatea) In respect of Contractors who are not registered with the EPF (Employees Provident Fund) authorities, the contractors should produce an undertaking that he shall within 7 days of the close of every month submit to the Executive Engineer, Hemavathy canal investigation division Hebburu, a statement showing the recoveries of contributions in respect of employees employed by him and shall also furnish under the provision of the scheme to the commissionerEPF.b) However, having given an undertaking to this effect if the contractor does not furnish the information, the Nigama will deduct the necessary amount from the amount due from the contractor. Not with standing the above, the contractor will be liable for any consequential penalty /damages levied by the EPF authorities.None
17096433200000NoneNoneELIGIBILITYMaterials required for the work shall be procured by the Contractor themselves and should get the same tested by the quality control authority of CNNL before use in this work.None
17096443830000NoneNoneELIGIBILITYPerformance securityWithin 20 days of receipt of the letter of acceptancesuccessful tenderer shall deliver to the employer a security deposit for an amount equivalent to 500 of the contract price & additional performance security for unbalanced tenders if quoted below in accordance with the clause 255 of ITT of the tender documentAs per Circular NoFD5Expenditure-12 -2023 dt10-02-2023 the requisite Security Deposit canalsobesubmitted in the form of e-Bank GuaranteeSuccessful bidder should execute work agreement within 20 days from the date of issue of Letter of acceptance failing which his tender will be cancelled & EMD will be forfeitedIf herate(s)quotedbyTenderer for any item (s) of work is are above 125of the estimated rates then the amount over andabove 125will be withheld during the progress of workNone
17096443970000NoneNoneELIGIBILITYSecurity Deposit Will be released after the completion of the defect liability periodNone
17096444200000NoneNoneELIGIBILITYSub leasing sub contracting in any form isprohibited. Bids of bidders with track record of Subleasing subcontracting are liable for rejectionNone
17096444840000NoneNoneELIGIBILITYThe intending bidders shall visit the site, identify the quarries ascertain availability for the quantity and quality of the materials required for theworkand shall quote his rates accordingly No extraclaim whatsoever will be entertained in this regardNone
17096445360000NoneNoneELIGIBILITYThe bidder should follow the instructions issued in the circular at 07-11-2023 of the mines & geology epartment regarding procurement of material from thelicensedminescontractorsAnyviolationinthisregard action will be taken as per the circularNone
17096445530000NoneNoneELIGIBILITYContractor should take all precautions to ensure that no damage is caused to the existing structures which have been constructed by other agencies during project execution. If any damage is caused it has to be rectified at his own risk and cost.None
17096445770000NoneNoneELIGIBILITYUploading of NSIC Certificate or Other certificate for relaxation of EMD Payment is not accepted as per government Order Dated 26.03.2019None
17096445920000NoneNoneELIGIBILITYCNNL reserves the right of rejecting all or any of the tenders without assigning any reasons.None
17096446030000NoneNoneELIGIBILITYTypo graphical errors if any will not be the ground for any claims by the contractor.None
17096446820000NoneNoneELIGIBILITYTenders shall remain valid for a period not less than ninety days after the deadline date for tender submission& earnest money deposit for the tender shall be valid for 45 days beyond the validity ofthe tenderNone
17096446980000NoneNoneELIGIBILITYThe undersigned reserves the right to either postpone or to cancel the entire process of tenderNone
17096447390000NoneNoneELIGIBILITYIn the case of the death of the contractor after executing the agreement / commencement of the workhis legal heirif is an eligible registered contractor and is willing can execute and compete the work at the accepted tender rates irrespective of the cost of the workNone
17096447990000NoneNoneELIGIBILITYIf CNNL wishes to engage third party consultants for quality control assessment apart from the CNNL quality control and field teststhe contractor should o-Operate with both Quality control authorities and the third partyNone
17096448490000NoneNoneELIGIBILITYRelated to qualification condition No 33Idlecharges for men & machineries for non-progress period delayed due to any reasons will not be paidNone
17097188270000NoneNoneELIGIBILITYAll other terms and conditions, and other conditions are as per Short Term tender notification No.08/2023-24 Dt 06-03-2024None
tenderTechnicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptionweightcriterionCategoryTextcriterionTypeOthersValuecriterionTypetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneSatisfactorily completed (atleast 90%) as prime contractor at-least one such similar work ( Project Management Consultancy in any Construction works) of value not less than Rs. 102.60 lakhs (50% of estimated cost of tender)5Past ExperienceNoneTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAchieved in at least two financial years a minimum financial turnover of value Rs.205.11 lakhs, Audited balance sheets certified by practicing Chartered Accountant along with UDIN should be mandatorily uploaded along with tender, failing which tender will be liable for rejection.(i.e, 2018-19 to 2022-23)5Financial StatusNoneTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLine of credit10Financial StatusNoneTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneThe firm should have own ISO certification in the field of PMC works10OthersISO certificationTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneOthers -- ISO certification
NoneNoneNoneNoneown or Tie up NABL certification5OthersothersTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneOthers -- others
NoneNoneNoneNoneKey professionals20OthersKey professionalsTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneOthers -- Key professionals
NoneNoneNoneNoneApproach and Methodology20OthersApproach and MethodologyTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneOthers -- Approach and Methodology
NoneNoneNoneNoneKey Equipments ( bidder/firm/Company/Consultants)25OthersKey EquipmentsTECHNICAL_QUALIFICATION
createdTsversioncreatedDatemodifiedDatedocumentTypeTextdocumentName
NoneNoneNoneNoneNoneOthers -- Key Equipments
tenderPreQualCriterionListNone
tenderAddress
createdTs1709734206560
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executivei Engineer, Hemavathy Canal Investigation Division, CNNL, Hebburu
streetNone
cityTumkur
stateKarnataka
pin572120
tenderRecallDTONone