2927279 | 96520 | None | RGU01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle | Sqm | 412.65 | 412.65 | 65.87 | False | None | None | False | None | False | 27181.2555 | 0 |
2927280 | 96520 | None | RGU02 | Earth work in surface excavation by mechanical means for lowering and leveling the ground for all works other than foundation in all kinds of soils and upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenances required to complete the work. | Cum | 99.75 | 99.75 | 996.19 | False | None | None | False | None | False | 99369.9525 | 0 |
2927281 | 96520 | None | RGU03 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 107.1 | 107.1 | 4763.31 | False | None | None | False | None | False | 510150.501 | 0 |
2927282 | 96520 | None | RGU04 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In ordinarysoft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 340.52 | False | None | None | False | None | False | 129789.198 | 0 |
2927283 | 96520 | None | RGU05 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m | Cum | 446.25 | 446.25 | 234.99 | False | None | None | False | None | False | 104864.2875 | 0 |
2927284 | 96520 | None | RGU06 | Loading and Unloading of Stone BoulderStone aggregates SandKankarMoorum. Disposal of 10Km | Cum | 141.75 | 141.75 | 2287.1 | False | None | None | False | None | False | 324196.425 | 0 |
2927285 | 96520 | None | RGU07 | Providing and injecting chemical emulsion for Preconstructional AntiTermite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percent E.C. Lindane 20percent E.C. at 3.19 lm2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 123.9 | 123.9 | 1604.92 | False | None | None | False | None | False | 198849.588 | 0 |
2927286 | 96520 | None | RGU08 | Filling available excavated earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 3513.14 | False | None | None | False | None | False | 981220.002 | 0 |
2927287 | 96520 | None | RGU09 | Construction of Embankment by excavating the available approved Gravel Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage and all other appurtenaces required to complete the work. | Cum | 497.7 | 497.7 | 1936.4 | False | None | None | False | None | False | 963746.28 | 0 |
2927288 | 96520 | None | RGU10 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6288.45 | 6288.45 | 500.24 | False | None | None | False | None | False | 3145734.228 | 0 |
2927289 | 96520 | None | RGU11 | Providing and laying in position Cement Concrete for all Foundation works. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. FOOTINGS | Cum | 7185.02 | 7185.02 | 1244.94 | False | None | None | False | None | False | 8944918.7988 | 0 |
2927290 | 96520 | None | RGU12 | Providing and laying in position Cement Concrete for all Foundation works. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. PEDESTAL | Cum | 7318.08 | 7318.08 | 13.72 | False | None | None | False | None | False | 100404.0576 | 0 |
2927291 | 96520 | None | RGU13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS GROUND FLOOR | Cum | 12507.5 | 12507.5 | 210.24 | False | None | None | False | None | False | 2629576.8 | 0 |
2927292 | 96520 | None | RGU14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. PLINTH BEAM GROUND FLOOR | Cum | 11036.03 | 11036.03 | 373.59 | False | None | None | False | None | False | 4122950.4477 | 0 |
2927293 | 96520 | None | RGU15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS GROUND FLOOR | Cum | 11771.76 | 11771.76 | 176.99 | False | None | None | False | None | False | 2083483.8024 | 0 |
2927294 | 96520 | None | RGU16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork GROUND FLOOR | Cum | 10094.18 | 10094.18 | 19.5 | False | None | None | False | None | False | 196836.51 | 0 |
2927295 | 96520 | None | RGU17 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with Cement Epoxy GROUND FLOOR | No | 214.2 | 214.2 | 100.0 | False | None | None | False | None | False | 21420.0 | 0 |
2927296 | 96520 | None | RGU18 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. GROUND FLOOR | Sqm | 1299.9 | 1299.9 | 13.95 | False | None | None | False | None | False | 18133.605 | 0 |
2927297 | 96520 | None | RGU19 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. GROUND FLOOR | Tonne | 93929.85 | 93929.85 | 251.63 | False | None | None | False | None | False | 23635568.1555 | 0 |
2927298 | 96520 | None | RGU20 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS GROUND FLOOR | Rmtr | 33.0 | 33.0 | 197.2 | False | None | None | False | None | False | 6507.6 | 0 |
2927299 | 96520 | None | RGU21 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas and parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. GROUND FLOOR | Rmtr | 73.0 | 73.0 | 1397.8 | False | None | None | False | None | False | 102039.4 | 0 |
2927300 | 96520 | None | RGU22 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200 mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 8376.9 | 8376.9 | 366.45 | False | None | None | False | None | False | 3069715.005 | 0 |
2927301 | 96520 | None | RGU23 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level in cement mortar 1:4 1 cement : 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. GROUND FLOOR | Cum | 8984.85 | 8984.85 | 23.41 | False | None | None | False | None | False | 210335.3385 | 0 |
2927302 | 96520 | None | RGU24 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR | Cum | 103755.75 | 103755.75 | 2.76 | False | None | None | False | None | False | 286365.87 | 0 |
2927303 | 96520 | None | RGU25 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Nos | 1066.8 | 1066.8 | 27.0 | False | None | None | False | None | False | 28803.6 | 0 |
2927304 | 96520 | None | RGU26 | Providing and fixing Stainless Steel Fixtures conforming to 304graded steel as per direction of engineer in charge.SS Handles 300mm GROUND FLOOR | Nos | 6825.0 | 6825.0 | 54.0 | False | None | None | False | None | False | 368550.0 | 0 |
2927305 | 96520 | None | RGU27 | Providing and fixing Stainless Steel Fixtures conforming to 304graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm GROUND FLOOR | Nos | 393.75 | 393.75 | 27.0 | False | None | None | False | None | False | 10631.25 | 0 |
2927306 | 96520 | None | RGU28 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm GROUND FLOOR | Nos | 157.5 | 157.5 | 50.0 | False | None | None | False | None | False | 7875.0 | 0 |
2927307 | 96520 | None | RGU29 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm GROUND FLOOR | Nos | 73.5 | 73.5 | 104.0 | False | None | None | False | None | False | 7644.0 | 0 |
2927308 | 96520 | None | RGU30 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm GROUND FLOOR | Nos | 105.0 | 105.0 | 27.0 | False | None | None | False | None | False | 2835.0 | 0 |
2927309 | 96520 | None | RGU31 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GROUND FLOOR | Nos | 1104.6 | 1104.6 | 27.0 | False | None | None | False | None | False | 29824.2 | 0 |
2927310 | 96520 | None | RGU32 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Nos | 63.0 | 63.0 | 162.0 | False | None | None | False | None | False | 10206.0 | 0 |
2927311 | 96520 | None | RGU33 | Providing and Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Rmtr | 12.71 | 12.71 | 708.4 | False | None | None | False | None | False | 9003.764 | 0 |
2927312 | 96520 | None | RGU34 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. GROUND FLOOR | Sqm | 4758.6 | 4758.6 | 78.24 | False | None | None | False | None | False | 372312.864 | 0 |
2927313 | 96520 | None | RGU35 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made GROUND FLOOR | Sqm | 7070.7 | 7070.7 | 93.3 | False | None | None | False | None | False | 659696.31 | 0 |
2927314 | 96520 | None | RGU36 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made GROUND FLOOR | Sqm | 6004.95 | 6004.95 | 7.2 | False | None | None | False | None | False | 43235.64 | 0 |
2927315 | 96520 | None | RGU37 | Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made GROUND FLOOR | Sqm | 5659.5 | 5659.5 | 18.9 | False | None | None | False | None | False | 106964.55 | 0 |
2927316 | 96520 | None | RGU38 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 176.4 | 176.4 | 2110.5 | False | None | None | False | None | False | 372292.2 | 0 |
2927317 | 96520 | None | RGU39 | Providing and fixing factory made single extruded WPC Wood Polymer Composite solid doorwindowClerestory windows and other Frames Chowkhat comprising of virgin PVC polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibres wood powderrice husk wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kgm3, screw withdrawal strength of 2200 N Face and 1100 N Edge , minimum compressive strength of 58 Nmm2 , modulus of elasticity 900 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixed in position with M.S hold fastlugsSS dash fasteners of required dia and length complete as per direction of EngineerInCharge. Fixtures shall be paid for separately Size 62 x 100mm GROUND FLOOR | Mtr | 737.1 | 737.1 | 55.0 | False | None | None | False | None | False | 40540.5 | 0 |
2927318 | 96520 | None | RGU40 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibers wood powderrice huskwheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kgm3 and screw withdrawal strength of 1800 N Face and 900 N Edge , minimum compressive strength of 50 Nmm2 , modulus of elasticity 850 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. Cost of Fixtures to be paid separately 30 mm thickness GROUND FLOOR | Sqm | 3659.25 | 3659.25 | 18.48 | False | None | None | False | None | False | 67622.94 | 0 |
2927319 | 96520 | None | RGU41 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. GROUND FLOOR | Nos | 1169.7 | 1169.7 | 27.0 | False | None | None | False | None | False | 31581.9 | 0 |
2927320 | 96520 | None | RGU42 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 339.15 | 339.15 | 2243.25 | False | None | None | False | None | False | 760798.2375 | 0 |
2927321 | 96520 | None | RGU43 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside GROUND FLOOR | Sqm | 327.6 | 327.6 | 2460.72 | False | None | None | False | None | False | 806131.872 | 0 |
2927322 | 96520 | None | RGU44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. GROUND FLOOR | Sqm | 105.0 | 105.0 | 4719.62 | False | None | None | False | None | False | 495560.1 | 0 |
2927323 | 96520 | None | RGU45 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside GROUND FLOOR | Sqm | 366.45 | 366.45 | 1285.04 | False | None | None | False | None | False | 470902.908 | 0 |
2927324 | 96520 | None | RGU46 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brickstone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineerincharge. GROUND FLOOR | Sqm | 371.7 | 371.7 | 124.63 | False | None | None | False | None | False | 46324.971 | 0 |
2927325 | 96520 | None | RGU47 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide GROUND FLOOR | Rmtr | 39.9 | 39.9 | 4418.4 | False | None | None | False | None | False | 176294.16 | 0 |
2927326 | 96520 | None | RGU48 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. GROUND FLOOR | Sqm | 240.0 | 240.0 | 620.0 | False | None | None | False | None | False | 148800.0 | 0 |
2927327 | 96520 | None | RGU49 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. GROUND FLOOR | Rmtr | 54.6 | 54.6 | 942.56 | False | None | None | False | None | False | 51463.776 | 0 |
2927328 | 96520 | None | RGU50 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1233.75 | 1233.75 | 847.01 | False | None | None | False | None | False | 1044998.5875 | 0 |
2927329 | 96520 | None | RGU51 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. GROUND FLOOR | Sqm | 2994.6 | 2994.6 | 631.49 | False | None | None | False | None | False | 1891059.954 | 0 |
2927330 | 96520 | None | RGU52 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 5594.4 | 5594.4 | 108.13 | False | None | None | False | None | False | 604922.472 | 0 |
2927331 | 96520 | None | RGU53 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. GROUND FLOOR | Sqm | 2711.1 | 2711.1 | 32.4 | False | None | None | False | None | False | 87839.64 | 0 |
2927332 | 96520 | None | RGU54 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately .Size of Tile 600x600 mm GROUND FLOOR | Sqm | 1392.3 | 1392.3 | 342.49 | False | None | None | False | None | False | 476848.827 | 0 |
2927333 | 96520 | None | RGU55 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade 0.10 kg of hardener and 0.20 kg of resin per kg , including filling grouting and finishing complete as per direction of Engineerincharge..Size of Tile 600x600 mm GROUND FLOOR | Sqm | 219.45 | 219.45 | 342.49 | False | None | None | False | None | False | 75159.4305 | 0 |
2927334 | 96520 | None | RGU56 | Providing and fixing of Wall Nut granite Patty fixing on above wall cladding border Excluding nosing using 19mm thick gang saw water cut in CM 1:3 proportion cut to required shape and , finished with cement mortal using Aerolite, white cement and colour pigments to match the colour of slab making through jointing with sealant, including cost of all materials, mortar, labour, curing etc., complete as per specification. GROUND FLOOR | Mtr | 335.0 | 335.0 | 2550.6 | False | None | None | False | None | False | 854451.0 | 0 |
2927335 | 96520 | None | RGU57 | Providing half nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification GROUND FLOOR | Mtr | 180.0 | 180.0 | 2551.28 | False | None | None | False | None | False | 459230.4 | 0 |
2927336 | 96520 | None | RGU58 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete GROUND FLOOR | Sqm | 3526.95 | 3526.95 | 15.45 | False | None | None | False | None | False | 54491.3775 | 0 |
2927337 | 96520 | None | RGU59 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 309.75 | 309.75 | 615.57 | False | None | None | False | None | False | 190672.8075 | 0 |
2927338 | 96520 | None | RGU60 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kgbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis GROUND FLOOR | Sqm | 645.75 | 645.75 | 94.32 | False | None | None | False | None | False | 60907.14 | 0 |
2927339 | 96520 | None | RGU61 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick ness to be specified by the manufacturer , of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand , jointing with grey cement slurry at 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete. GROUND FLOOR | Sqm | 933.45 | 933.45 | 60.16 | False | None | None | False | None | False | 56156.352 | 0 |
2927340 | 96520 | None | RGU62 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1521.45 | 1521.45 | 257.63 | False | None | None | False | None | False | 391971.1635 | 0 |
2927341 | 96520 | None | RGU63 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand , joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 GROUND FLOOR | Sqm | 4133.85 | 4133.85 | 9.35 | False | None | None | False | None | False | 38651.4975 | 0 |
2927342 | 96520 | None | RGU64 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineerin charge and finished smooth. GROUND FLOOR | Sqm | 2928.45 | 2928.45 | 2.7 | False | None | None | False | None | False | 7906.815 | 0 |
2927343 | 96520 | None | RGU65 | Providing full nosing for 40mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification GROUND FLOOR | Mtr | 540.0 | 540.0 | 909.37 | False | None | None | False | None | False | 491059.8 | 0 |
2927344 | 96520 | None | RGU66 | Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, ic fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. GROUND FLOOR | Kgs | 593.25 | 593.25 | 27.03 | False | None | None | False | None | False | 16035.5475 | 0 |
2927345 | 96520 | None | RGU67 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge GROUND FLOOR | Sqm | 115.5 | 115.5 | 4844.25 | False | None | None | False | None | False | 559510.875 | 0 |
2927346 | 96520 | None | RGU68 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 163.8 | 163.8 | 787.69 | False | None | None | False | None | False | 129023.622 | 0 |
2927347 | 96520 | None | RGU69 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 297.15 | 297.15 | 497.35 | False | None | None | False | None | False | 147787.5525 | 0 |
2927348 | 96520 | None | RGU70 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 52.5 | 52.5 | 119.88 | False | None | None | False | None | False | 6293.7 | 0 |
2927349 | 96520 | None | RGU71 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 120.75 | 120.75 | 119.88 | False | None | None | False | None | False | 14475.51 | 0 |
2927350 | 96520 | None | RGU72 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. GROUND FLOOR | Sqm | 55.65 | 55.65 | 187.78 | False | None | None | False | None | False | 10449.957 | 0 |
2927351 | 96520 | None | RGU73 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. GROUND FLOOR | Sqm | 710.85 | 710.85 | 187.78 | False | None | None | False | None | False | 133483.413 | 0 |
2927352 | 96520 | None | RGU74 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. GROUND FLOOR | Kg | 154.35 | 154.35 | 1298.7 | False | None | None | False | None | False | 200454.345 | 0 |
2927353 | 96520 | None | RGU75 | Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account .The weight of aluminium extruded section shall be taken for purpose of payment. GROUND FLOOR | Kg | 427.35 | 427.35 | 562.77 | False | None | None | False | None | False | 240499.7595 | 0 |
2927354 | 96520 | None | RGU76 | Providing, assembling and supplying vision glass panels IGUs comprising of hermeticallysealed 612 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal structural silicone sealant etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2 For payment, only the actual area of glass on face 1 of the glass panels excluding the areas of the grooves and weather silicone sealant provided and fixed in position, shall be measured in m2. i Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance VLT of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient 0.250.28 and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. GROUND FLOOR | Sqm | 3195.15 | 3195.15 | 86.58 | False | None | None | False | None | False | 276636.087 | 0 |
2927355 | 96520 | None | RGU77 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet zinc coating not less than 120 gmsqm duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm minimum alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineerincharge Dash fastener to bepaid for separately . GROUND FLOOR | Mtr | 1306.03 | 1306.03 | 449.7 | False | None | None | False | None | False | 587321.691 | 0 |
2927356 | 96520 | None | RGU78 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 PartII , tested and certified as per laboratory approved by Engineerincharge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet zinc coating not less than 120 gmm2 duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineerincharge panneling to be paid for separately . GROUND FLOOR | Sqm | 5754.42 | 5754.42 | 130.68 | False | None | None | False | None | False | 751987.6056 | 0 |
2927357 | 96520 | None | RGU79 | Providing,Fabricating,Assembling and Fixing in position plain 12mm thick toughend glass and Alround beading are cut to the required length and Shape, joints mitred and corners grinded an fixed with the screws rawl plugs and Clamps to Door frame with good Finishing all the frames glass,cleaned free from rust scale or dirt including cost of materials fixtures labours and hom of Machineris complete as per specification GROUND FLOOR | Sqm | 4500.0 | 4500.0 | 153.0 | False | None | None | False | None | False | 688500.0 | 0 |
2927358 | 96520 | None | RGU80 | Providing and fixing of expansion joint system related with floor location as per drawings and direction of EngineerInCharge. The joints system will be of extruded aluminum base members, self aligning self centering arrangement and support plates etc. as per ASTM B22102. The system shall be such that it provides floor to floor floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered self centering arrangement that freely rotates moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer inCharge. Material shall confirm to ASTM 6063 . Floor Joint of 50 mm gap. GROUND FLOOR | Mtr | 4915.38 | 4915.38 | 264.0 | False | None | None | False | None | False | 1297660.32 | 0 |
2927359 | 96520 | None | RGU81 | Providing and fixing of expansion joint system related with wall joint internalexternal location as per drawings and direction of EngineerInCharge. The joints shall be of extruded aluminum base members, self aligning centering arrangement and support plates as per ASTM B221 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall wall to corner application, both new and existing construction in office Buildings and complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Material shall confirm to ASTM 6063 Wall Joint of 50 mm gap GROUND FLOOR | Mtr | 4097.88 | 4097.88 | 264.0 | False | None | None | False | None | False | 1081840.32 | 0 |
2927360 | 96520 | None | RGU82 | Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of EngineerInCharge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B22102. The system shall be such that it provides watertight roof to roofroof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s preengineered selfcentering arrangement that freely rotates moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. Material shall confirm to ASTM 6063 . Roof Joint of 100 mm gap. GROUND FLOOR | Mtr | 4596.78 | 4596.78 | 451.2 | False | None | None | False | None | False | 2074067.136 | 0 |
2927361 | 96520 | None | RGU83 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. GROUND FLOOR | Kg | 474.6 | 474.6 | 141.6 | False | None | None | False | None | False | 67203.36 | 0 |
2927362 | 96520 | None | RGU84 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings and bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 845.82 | False | None | None | False | None | False | 214922.862 | 0 |
2927363 | 96520 | None | RGU85 | Compacting original ground supporting embankmentLoosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 3002 for embankment construction. | Cum | 110.25 | 110.25 | 1569.0 | False | None | None | False | None | False | 172982.25 | 0 |
2927364 | 96520 | None | RGU86 | Construction of Granular SubBase of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading V Material | Cum | 2611.35 | 2611.35 | 235.35 | False | None | None | False | None | False | 614581.2225 | 0 |
2927365 | 96520 | None | RGU87 | Construction of dry lean cement concrete Sub base over a prepared subgrade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 14:1, aggregate gradation after blending to be as per table 6001, cement content not to be less than 140 kg m3 , optimum moisture content to be determined during trial length construction, concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 810 t vibratory roller, finishing and curing. | Cum | 5166.0 | 5166.0 | 235.35 | False | None | None | False | None | False | 1215818.1 | 0 |
2927366 | 96520 | None | RGU88 | Construction of M40 Grade unreinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing. Construction of M40 Grade unreinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawing | Cum | 9514.05 | 9514.05 | 313.8 | False | None | None | False | None | False | 2985508.89 | 0 |
2927367 | 96520 | None | RGU89 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 48 hours of casting of bay slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge. | Mtr | 73.5 | 73.5 | 523.0 | False | None | None | False | None | False | 38440.5 | 0 |
2927368 | 96520 | None | RGU90 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. The cost of PCC shall be paid extra 600 x 200 x 100 mm Kerb Stone | Mtr | 262.5 | 262.5 | 553.0 | False | None | None | False | None | False | 145162.5 | 0 |
2927369 | 96520 | None | RGU91 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. | Sqm | 114.45 | 114.45 | 386.44 | False | None | None | False | None | False | 44228.058 | 0 |
2927370 | 96520 | None | RGU92 | Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164:2015 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control. Over 10 cm in width | Sqm | 213.15 | 213.15 | 69.01 | False | None | None | False | None | False | 14709.4815 | 0 |
2927371 | 96520 | None | RGU93 | Providing, laying and fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to halffull round wherever required, labour, curing complete as per specification. | Sqm | 978.6 | 978.6 | 193.05 | False | None | None | False | None | False | 188918.73 | 0 |
2927372 | 96520 | None | RGU94 | Providing and laying in position Cement Concrete for all Foundation works. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. FOOTINGS | Cum | 6852.38 | 6852.38 | 1.54 | False | None | None | False | None | False | 10552.6652 | 0 |
2927373 | 96520 | None | RGU95 | Providing and laying in position Cement Concrete for all Foundation works. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork. PLINTH BEAM | Cum | 9979.2 | 9979.2 | 2.82 | False | None | None | False | None | False | 28141.344 | 0 |
2927374 | 96520 | None | RGU96 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork COLUMNS | Cum | 12214.76 | 12214.76 | 77.58 | False | None | None | False | None | False | 947621.0808 | 0 |
2927375 | 96520 | None | RGU97 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ROOF BEAMS | Cum | 11496.24 | 11496.24 | 5.94 | False | None | None | False | None | False | 68287.6656 | 0 |
2927376 | 96520 | None | RGU98 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ROOF SLAB | Cum | 10777.73 | 10777.73 | 23.82 | False | None | None | False | None | False | 256725.5286 | 0 |
2927377 | 96520 | None | RGU99 | Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 1 cement : 6 coarse sand | Cum | 6708.45 | 6708.45 | 0.63 | False | None | None | False | None | False | 4226.3235 | 0 |
2927378 | 96520 | None | RGU100 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1375.5 | 1375.5 | 132.21 | False | None | None | False | None | False | 181854.855 | 0 |
2927379 | 96520 | None | RGU101 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.. | Cum | 4701.9 | 4701.9 | 12.18 | False | None | None | False | None | False | 57269.142 | 0 |
2927380 | 96520 | None | RGU102 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terraceChajjasSunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6 kgm2 to achieve final DFT Dry Film Thickness of 1mm including prime coat of epoxy primer at150 gm2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 857.85 | 857.85 | 9.24 | False | None | None | False | None | False | 7926.534 | 0 |
2927381 | 96520 | None | RGU103 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate finished with a floating coat of neat cement, including cement slurry complete | Sqm | 473.55 | 473.55 | 10.8 | False | None | None | False | None | False | 5114.34 | 0 |
2927382 | 96520 | None | RGU104 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 431.55 | 431.55 | 13.5 | False | None | None | False | None | False | 5825.925 | 0 |
2927383 | 96520 | None | RGU105 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth 3 to 6 m | Cum | 122.85 | 122.85 | 50.88 | False | None | None | False | None | False | 6250.608 | 0 |
2927384 | 96520 | None | RGU106 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work Depth exceeding 3 m, but not exceeding 4.5 m | Cum | 486.15 | 486.15 | 14.54 | False | None | None | False | None | False | 7068.621 | 0 |
2927385 | 96520 | None | RGU107 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement, dowel bars to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including Formwork. FOOTING | Cum | 7400.7 | 7400.7 | 46.73 | False | None | None | False | None | False | 345834.711 | 0 |
2927386 | 96520 | None | RGU108 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork | Cum | 9465.38 | 9465.38 | 0.56 | False | None | None | False | None | False | 5300.6128 | 0 |
2927387 | 96520 | None | RGU109 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | Tonne | 82961.55 | 82961.55 | 22.88 | False | None | None | False | None | False | 1898160.264 | 0 |
2927388 | 96520 | None | RGU110 | Steel Windows with grill for residential buildingsProviding and fixing of windows made of prepainted steel base steel as per IS 513 of0.58mm tick galvanized as per IS 277 with zinc of 120 GSM . Primer coated with epoxy primer of 57 microns thick, finish painted with a polyester paint of 1216 microns thick and back coated with 57microns thick alkyd backer. Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm, section for shutter should be of 48x25mm and fixed glass beading section should be of 12x12mm. Outer frame and mullions to have rebate for glazed shutter and a 20mm provision for guard barsgrills. The sections are to be cut to length mitre joined with corner bracket. Centre mullion is to be fixed with mullion cap. Handle stay 2Nos of stainless steel heavy duty pivot hinges shall be provided for shutter. The window should be panelled with 5mm thick plain fioat glass. Rubber gaskets are to be provided all around the glass. The above frames should be fixed to the concrete masonry wall by means of self expanding screws, including 10mm square guard bars with 6inches 152.4mm pitch etc., complete for finished item of work. | Sqm | 3758.0 | 3758.0 | 7.2 | False | None | None | False | None | False | 27057.6 | 0 |
2927389 | 96520 | None | RGU111 | UGTOHT inside waterproofing with Antimicrobial CoatingProviding and Applying two component, waterbased food grade epoxy resin coating on inside surface of Potable water tank having antialgae, antifungal, Nontoxic, hygiene cum dampproof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio Base: Hardener: Water 1:1:1 to be applied at 0.35 Kgm2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 gm224 hrs, as per IS 7809Pt 21977, Adhesion strength: 2 Nmm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. | Sqm | 1756.65 | 1756.65 | 223.2 | False | None | None | False | None | False | 392084.28 | 0 |
2927390 | 96520 | None | RGU112 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 1 cement : 5 coarse sand finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 1 cement : 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. | Sqm | 389.55 | 389.55 | 777.46 | False | None | None | False | None | False | 302859.543 | 0 |
2927391 | 96520 | None | RGU113 | Providing White washing with lime to give an even shade :New work three coats with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineerincharge. | Sqm | 27.3 | 27.3 | 777.46 | False | None | None | False | None | False | 21224.658 | 0 |
2927392 | 96520 | None | RGU114 | Finishing walls with water proofing cement paint of required shade :New work Two coats applied at 4.84 kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. | Sqm | 93.45 | 93.45 | 785.46 | False | None | None | False | None | False | 73401.237 | 0 |
2927393 | 96520 | None | RGU115 | Providing and fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs weight of cover 23 kgs and weight of frame 15 kgs and necessary locking arrangements with M.S flats 32x6 mm etc and painting with two or more coats with black Japan paint etc. complete as directed by the engineerincharge. | Nos | 2060.1 | 2060.1 | 16.0 | False | None | None | False | None | False | 32961.6 | 0 |
2927394 | 96520 | None | RGU116 | STP inside waterproofing with Anticorrosive and Protective CoatingProviding and Applying two component coal tar epoxybased coating on inside surface of Sewage and Effluent treatment tank at 0.30 kgm2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 05, Chemical resistance, immersion in dilute acid alkali and salt solutions 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117. The finished cost to include surface preparation completely as per specification. | Sqm | 1748.25 | 1748.25 | 258.4 | False | None | None | False | None | False | 451747.8 | 0 |
2927395 | 96520 | None | RGU117 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings and bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 m | Cum | 271.95 | 271.95 | 25.45 | False | None | None | False | None | False | 6921.1275 | 0 |
2927396 | 96520 | None | RGU118 | Providing and fixing factory made precast RCC perforated rings, having concrete of strength not less than M25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal and 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations at 100 to 125 mm cc, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerincharge. | Each | 1179.15 | 1179.15 | 105.0 | False | None | None | False | None | False | 123810.75 | 0 |
2927397 | 96520 | None | RGU119 | Supplying, filling, spreading and leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineerincharge | Cum | 1052.1 | 1052.1 | 4.24 | False | None | None | False | None | False | 4460.904 | 0 |
2927398 | 96520 | None | RGU120 | Supplying, filling, spreading andleveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads and lifts, all complete as per direction of Engineerincharge. | Cum | 1245.3 | 1245.3 | 2.12 | False | None | None | False | None | False | 2640.036 | 0 |
2927399 | 96520 | None | RGU121 | Supplying, filling, spreading andleveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads and lifts, all complete as per direction of Engineer incharge. | Cum | 1251.6 | 1251.6 | 2.12 | False | None | None | False | None | False | 2653.392 | 0 |
2927400 | 96520 | None | RGU122 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine medium coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineerincharge. | Cum | 1405.95 | 1405.95 | 2.4 | False | None | None | False | None | False | 3374.28 | 0 |
2927401 | 96520 | None | RGU123 | Providing and laying 100mm thick precast cover slabs over Road side drains utility ducts Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 at 6kg m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1228.5 | 1228.5 | 15.0 | False | None | None | False | None | False | 18427.5 | 0 |
2927402 | 96520 | None | RGU124 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS FIRST FLOOR | Cum | 12632.57 | 12632.57 | 134.08 | False | None | None | False | None | False | 1693774.9856 | 0 |
2927403 | 96520 | None | RGU125 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS FIRST FLOOR | Cum | 11889.48 | 11889.48 | 150.87 | False | None | None | False | None | False | 1793765.8476 | 0 |
2927404 | 96520 | None | RGU126 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB FIRST FLOOR | Cum | 11146.39 | 11146.39 | 219.63 | False | None | None | False | None | False | 2448081.6357 | 0 |
2927405 | 96520 | None | RGU127 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC STAIRCASE FIRST FLOOR | Cum | 11146.39 | 11146.39 | 21.04 | False | None | None | False | None | False | 234520.0456 | 0 |
2927406 | 96520 | None | RGU128 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. LINTELS FIRST FLOOR | Cum | 11889.48 | 11889.48 | 23.95 | False | None | None | False | None | False | 284753.046 | 0 |
2927407 | 96520 | None | RGU129 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FIRST FLOOR | Cum | 10195.12 | 10195.12 | 18.89 | False | None | None | False | None | False | 192585.8168 | 0 |
2927408 | 96520 | None | RGU130 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with Cement Epoxy FIRST FLOOR | No | 216.34 | 216.34 | 100.0 | False | None | None | False | None | False | 21634.0 | 0 |
2927409 | 96520 | None | RGU131 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FIRST FLOOR | Tonne | 94869.15 | 94869.15 | 89.9 | False | None | None | False | None | False | 8528736.585 | 0 |
2927410 | 96520 | None | RGU132 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS FIRST FLOOR | Rmtr | 33.0 | 33.0 | 189.4 | False | None | None | False | None | False | 6250.2 | 0 |
2927411 | 96520 | None | RGU133 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. FIRST FLOOR | Cum | 8460.67 | 8460.67 | 365.78 | False | None | None | False | None | False | 3094743.8726 | 0 |
2927412 | 96520 | None | RGU134 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level in cement mortar 1:4 1 cement : 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. FIRST FLOOR | Cum | 9074.7 | 9074.7 | 16.04 | False | None | None | False | None | False | 145558.188 | 0 |
2927413 | 96520 | None | RGU135 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOOR | Cum | 104793.31 | 104793.31 | 1.77 | False | None | None | False | None | False | 185484.1587 | 0 |
2927414 | 96520 | None | RGU136 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FIRST FLOOR | Nos | 1077.47 | 1077.47 | 22.0 | False | None | None | False | None | False | 23704.34 | 0 |
2927415 | 96520 | None | RGU137 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm FIRST FLOOR | Nos | 6893.25 | 6893.25 | 44.0 | False | None | None | False | None | False | 303303.0 | 0 |
2927416 | 96520 | None | RGU138 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm FIRST FLOOR | Nos | 397.69 | 397.69 | 22.0 | False | None | None | False | None | False | 8749.18 | 0 |
2927417 | 96520 | None | RGU139 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm FIRST FLOOR | Nos | 159.08 | 159.08 | 44.0 | False | None | None | False | None | False | 6999.52 | 0 |
2927418 | 96520 | None | RGU140 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm FIRST FLOOR | Nos | 74.24 | 74.24 | 88.0 | False | None | None | False | None | False | 6533.12 | 0 |
2927419 | 96520 | None | RGU141 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm FIRST FLOOR | Nos | 106.05 | 106.05 | 22.0 | False | None | None | False | None | False | 2333.1 | 0 |
2927420 | 96520 | None | RGU142 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIRST FLOOR | Nos | 1115.65 | 1115.65 | 22.0 | False | None | None | False | None | False | 24544.3 | 0 |
2927421 | 96520 | None | RGU143 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIRST FLOOR | Nos | 63.63 | 63.63 | 132.0 | False | None | None | False | None | False | 8399.16 | 0 |
2927422 | 96520 | None | RGU144 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. FIRST FLOOR | Sqm | 4806.19 | 4806.19 | 70.08 | False | None | None | False | None | False | 336817.7952 | 0 |
2927423 | 96520 | None | RGU145 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FIRST FLOOR | Sqm | 7141.41 | 7141.41 | 86.4 | False | None | None | False | None | False | 617017.824 | 0 |
2927424 | 96520 | None | RGU146 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FIRST FLOOR | Sqm | 6065.0 | 6065.0 | 6.84 | False | None | None | False | None | False | 41484.6 | 0 |
2927425 | 96520 | None | RGU147 | Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FIRST FLOOR | Sqm | 5716.1 | 5716.1 | 14.4 | False | None | None | False | None | False | 82311.84 | 0 |
2927426 | 96520 | None | RGU148 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR | Kg | 178.16 | 178.16 | 1958.04 | False | None | None | False | None | False | 348844.4064 | 0 |
2927427 | 96520 | None | RGU149 | Providing and fixing factory made single extruded WPC Wood Polymer Composite solid doorwindowClerestory windows and other Frames Chowkhat comprising of virgin PVC polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibres wood powderrice husk wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kgm3, screw withdrawal strength of 2200 N Face and 1100 N Edge , minimum compressive strength of 58 Nmm2 , modulus of elasticity 900 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixed in position with M.S hold fastlugsSS dash fasteners of required dia and length complete as per direction of EngineerInCharge. Fixtures shall be paid for separately Size 62 x 100mm FIRST FLOOR | Rmtr | 744.47 | 744.47 | 50.0 | False | None | None | False | None | False | 37223.5 | 0 |
2927428 | 96520 | None | RGU150 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibers wood powderrice huskwheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kgm3 and screw withdrawal strength of 1800 N Face and 900 N Edge , minimum compressive strength of 50 Nmm2 , modulus of elasticity 850 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. Cost of Fixtures to be paid separately 30 mm thickness FIRST FLOOR | Sqm | 3695.84 | 3695.84 | 16.8 | False | None | None | False | None | False | 62090.112 | 0 |
2927429 | 96520 | None | RGU151 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. FIRST FLOOR | Nos | 1181.4 | 1181.4 | 22.0 | False | None | None | False | None | False | 25990.8 | 0 |
2927430 | 96520 | None | RGU152 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 342.54 | 342.54 | 2238.8 | False | None | None | False | None | False | 766878.552 | 0 |
2927431 | 96520 | None | RGU153 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside FIRST FLOOR | Sqm | 330.88 | 330.88 | 2182.35 | False | None | None | False | None | False | 722095.968 | 0 |
2927432 | 96520 | None | RGU154 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIRST FLOOR | Sqm | 106.05 | 106.05 | 4421.15 | False | None | None | False | None | False | 468862.9575 | 0 |
2927433 | 96520 | None | RGU155 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside FIRST FLOOR | Sqm | 370.11 | 370.11 | 1249.89 | False | None | None | False | None | False | 462596.7879 | 0 |
2927434 | 96520 | None | RGU156 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brickstone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineerincharge. FIRST FLOOR | Sqm | 375.42 | 375.42 | 118.15 | False | None | None | False | None | False | 44355.873 | 0 |
2927435 | 96520 | None | RGU157 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide FIRST FLOOR | Rmtr | 40.3 | 40.3 | 4155.3 | False | None | None | False | None | False | 167458.59 | 0 |
2927436 | 96520 | None | RGU158 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. FIRST FLOOR | Rmtr | 55.15 | 55.15 | 942.56 | False | None | None | False | None | False | 51982.184 | 0 |
2927437 | 96520 | None | RGU159 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm FIRST FLOOR | Sqm | 1246.09 | 1246.09 | 760.43 | False | None | None | False | None | False | 947564.2187 | 0 |
2927438 | 96520 | None | RGU160 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FIRST FLOOR | Sqm | 3024.55 | 3024.55 | 498.11 | False | None | None | False | None | False | 1506558.6005 | 0 |
2927439 | 96520 | None | RGU161 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. FIRST FLOOR | Sqm | 5650.34 | 5650.34 | 131.93 | False | None | None | False | None | False | 745449.3562 | 0 |
2927440 | 96520 | None | RGU162 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately .Size of Tile 600x600 mm FIRST FLOOR | Sqm | 1406.22 | 1406.22 | 329.77 | False | None | None | False | None | False | 463729.1694 | 0 |
2927441 | 96520 | None | RGU163 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade 0.10 kg of hardener and 0.20 kg of resin per kg , including filling grouting and finishing complete as per direction of Engineerincharge..Size of Tile 600x600 mm FIRST FLOOR | Sqm | 221.64 | 221.64 | 329.77 | False | None | None | False | None | False | 73090.2228 | 0 |
2927442 | 96520 | None | RGU164 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete FIRST FLOOR | Sqm | 3562.22 | 3562.22 | 15.45 | False | None | None | False | None | False | 55036.299 | 0 |
2927443 | 96520 | None | RGU165 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 312.85 | 312.85 | 552.45 | False | None | None | False | None | False | 172833.9825 | 0 |
2927444 | 96520 | None | RGU166 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kgbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis FIRST FLOOR | Sqm | 652.21 | 652.21 | 88.96 | False | None | None | False | None | False | 58020.6016 | 0 |
2927445 | 96520 | None | RGU167 | Providing and laying cinder concrete in cement 1:15 1 cement : 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FIRST FLOOR | Cum | 2139.03 | 2139.03 | 17.09 | False | None | None | False | None | False | 36556.0227 | 0 |
2927446 | 96520 | None | RGU168 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick ness to be specified by the manufacturer , of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand , jointing with grey cement slurry at 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete. FIRST FLOOR | Sqm | 942.78 | 942.78 | 56.96 | False | None | None | False | None | False | 53700.7488 | 0 |
2927447 | 96520 | None | RGU169 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 1536.66 | 1536.66 | 207.23 | False | None | None | False | None | False | 318442.0518 | 0 |
2927448 | 96520 | None | RGU170 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand , joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 FIRST FLOOR | Sqm | 4175.19 | 4175.19 | 6.2 | False | None | None | False | None | False | 25886.178 | 0 |
2927449 | 96520 | None | RGU171 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineerin charge and finished smooth. FIRST FLOOR | Sqm | 2957.73 | 2957.73 | 2.7 | False | None | None | False | None | False | 7985.871 | 0 |
2927450 | 96520 | None | RGU172 | Providing full nosing for 40mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM etc., complete as per specification FIRST FLOOR | Mtr | 540.0 | 540.0 | 10.33 | False | None | None | False | None | False | 5578.2 | 0 |
2927451 | 96520 | None | RGU173 | Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, ic fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FIRST FLOOR | Kgs | 599.18 | 599.18 | 673.7 | False | None | None | False | None | False | 403667.566 | 0 |
2927452 | 96520 | None | RGU174 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge FIRST FLOOR | Sqm | 116.66 | 116.66 | 4539.3 | False | None | None | False | None | False | 529554.738 | 0 |
2927453 | 96520 | None | RGU175 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 165.44 | 165.44 | 749.93 | False | None | None | False | None | False | 124068.4192 | 0 |
2927454 | 96520 | None | RGU176 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 300.12 | 300.12 | 499.96 | False | None | None | False | None | False | 150047.9952 | 0 |
2927455 | 96520 | None | RGU177 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 53.03 | 53.03 | 93.24 | False | None | None | False | None | False | 4944.5172 | 0 |
2927456 | 96520 | None | RGU178 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 121.96 | 121.96 | 93.24 | False | None | None | False | None | False | 11371.5504 | 0 |
2927457 | 96520 | None | RGU179 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIRST FLOOR | Sqm | 56.21 | 56.21 | 168.19 | False | None | None | False | None | False | 9453.9599 | 0 |
2927458 | 96520 | None | RGU180 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. FIRST FLOOR | Sqm | 717.96 | 717.96 | 168.19 | False | None | None | False | None | False | 120753.6924 | 0 |
2927459 | 96520 | None | RGU181 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FIRST FLOOR | Kg | 155.89 | 155.89 | 1298.7 | False | None | None | False | None | False | 202454.343 | 0 |
2927460 | 96520 | None | RGU182 | Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account .The weight of aluminium extruded section shall be taken for purpose of payment. FIRST FLOOR | Kg | 431.62 | 431.62 | 562.77 | False | None | None | False | None | False | 242902.7874 | 0 |
2927461 | 96520 | None | RGU183 | Providing, assembling and supplying vision glass panels IGUs comprising of hermeticallysealed 612 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal structural silicone sealant etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2 For payment, only the actual area of glass on face 1 of the glass panels excluding the areas of the grooves and weather silicone sealant provided and fixed in position, shall be measured in m2. i Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance VLT of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient 0.250.28 and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. FIRST FLOOR | Sqm | 3227.1 | 3227.1 | 86.58 | False | None | None | False | None | False | 279402.318 | 0 |
2927462 | 96520 | None | RGU184 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. FIRST FLOOR | Kg | 479.35 | 479.35 | 142.35 | False | None | None | False | None | False | 68235.4725 | 0 |
2927463 | 96520 | None | RGU185 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS SECOND FLOOR | Cum | 12757.64 | 12757.64 | 134.08 | False | None | None | False | None | False | 1710544.3712 | 0 |
2927464 | 96520 | None | RGU186 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS SECOND FLOOR | Cum | 12007.2 | 12007.2 | 151.66 | False | None | None | False | None | False | 1821011.952 | 0 |
2927465 | 96520 | None | RGU187 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB SECOND FLOOR | Cum | 11256.75 | 11256.75 | 215.67 | False | None | None | False | None | False | 2427743.2725 | 0 |
2927466 | 96520 | None | RGU188 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC STAIRCASE SECOND FLOOR | Cum | 11256.75 | 11256.75 | 21.04 | False | None | None | False | None | False | 236842.02 | 0 |
2927467 | 96520 | None | RGU189 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. LINTELS SECOND FLOOR | Cum | 12007.2 | 12007.2 | 23.19 | False | None | None | False | None | False | 278446.968 | 0 |
2927468 | 96520 | None | RGU190 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork SECOND FLOOR | Cum | 10296.06 | 10296.06 | 17.68 | False | None | None | False | None | False | 182034.3408 | 0 |
2927469 | 96520 | None | RGU191 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with Cement Epoxy SECOND FLOOR | No | 218.48 | 218.48 | 100.0 | False | None | None | False | None | False | 21848.0 | 0 |
2927470 | 96520 | None | RGU192 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. SECOND FLOOR | Tonne | 95808.45 | 95808.45 | 86.93 | False | None | None | False | None | False | 8328628.5585 | 0 |
2927471 | 96520 | None | RGU193 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS SECOND FLOOR | Rmtr | 33.0 | 33.0 | 191.0 | False | None | None | False | None | False | 6303.0 | 0 |
2927472 | 96520 | None | RGU194 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. SECOND FLOOR | Cum | 8544.44 | 8544.44 | 344.55 | False | None | None | False | None | False | 2943986.802 | 0 |
2927473 | 96520 | None | RGU195 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level in cement mortar 1:4 1 cement : 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. SECOND FLOOR | Cum | 9164.55 | 9164.55 | 67.1 | False | None | None | False | None | False | 614941.305 | 0 |
2927474 | 96520 | None | RGU196 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. SECOND FLOOR | Cum | 105830.87 | 105830.87 | 1.43 | False | None | None | False | None | False | 151338.1441 | 0 |
2927475 | 96520 | None | RGU197 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. SECOND FLOOR | Nos | 1088.14 | 1088.14 | 18.0 | False | None | None | False | None | False | 19586.52 | 0 |
2927476 | 96520 | None | RGU198 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm SECOND FLOOR | Nos | 6961.5 | 6961.5 | 36.0 | False | None | None | False | None | False | 250614.0 | 0 |
2927477 | 96520 | None | RGU199 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm SECOND FLOOR | Nos | 401.63 | 401.63 | 18.0 | False | None | None | False | None | False | 7229.34 | 0 |
2927478 | 96520 | None | RGU200 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm SECOND FLOOR | Nos | 160.65 | 160.65 | 36.0 | False | None | None | False | None | False | 5783.4 | 0 |
2927479 | 96520 | None | RGU201 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm SECOND FLOOR | Nos | 74.97 | 74.97 | 72.0 | False | None | None | False | None | False | 5397.84 | 0 |
2927480 | 96520 | None | RGU202 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm SECOND FLOOR | Nos | 107.1 | 107.1 | 18.0 | False | None | None | False | None | False | 1927.8 | 0 |
2927481 | 96520 | None | RGU203 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SECOND FLOOR | Nos | 1126.69 | 1126.69 | 18.0 | False | None | None | False | None | False | 20280.42 | 0 |
2927482 | 96520 | None | RGU204 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm SECOND FLOOR | Nos | 64.26 | 64.26 | 108.0 | False | None | None | False | None | False | 6940.08 | 0 |
2927483 | 96520 | None | RGU205 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. SECOND FLOOR | Sqm | 4853.77 | 4853.77 | 53.76 | False | None | None | False | None | False | 260938.6752 | 0 |
2927484 | 96520 | None | RGU206 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineerincharge Door handle, lock and stopper etc. to be paid separately including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. SECOND FLOOR | Sqm | 5057.26 | 5057.26 | 17.4 | False | None | None | False | None | False | 87996.324 | 0 |
2927485 | 96520 | None | RGU207 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made SECOND FLOOR | Sqm | 7212.11 | 7212.11 | 81.0 | False | None | None | False | None | False | 584180.91 | 0 |
2927486 | 96520 | None | RGU208 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made SECOND FLOOR | Sqm | 6125.05 | 6125.05 | 8.28 | False | None | None | False | None | False | 50715.414 | 0 |
2927487 | 96520 | None | RGU209 | Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made SECOND FLOOR | Sqm | 5772.69 | 5772.69 | 27.96 | False | None | None | False | None | False | 161404.4124 | 0 |
2927488 | 96520 | None | RGU210 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding SECOND FLOOR | Kg | 179.93 | 179.93 | 1874.88 | False | None | None | False | None | False | 337347.1584 | 0 |
2927489 | 96520 | None | RGU211 | Providing and fixing factory made single extruded WPC Wood Polymer Composite solid doorwindowClerestory windows and other Frames Chowkhat comprising of virgin PVC polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibres wood powderrice husk wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kgm3, screw withdrawal strength of 2200 N Face and 1100 N Edge , minimum compressive strength of 58 Nmm2 , modulus of elasticity 900 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixed in position with M.S hold fastlugsSS dash fasteners of required dia and length complete as per direction of EngineerInCharge. Fixtures shall be paid for separately Size 62 x 100mm SECOND FLOOR | Rmtr | 751.84 | 751.84 | 60.0 | False | None | None | False | None | False | 45110.4 | 0 |
2927490 | 96520 | None | RGU212 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibers wood powderrice huskwheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kgm3 and screw withdrawal strength of 1800 N Face and 900 N Edge , minimum compressive strength of 50 Nmm2 , modulus of elasticity 850 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. Cost of Fixtures to be paid separately 30 mm thickness SECOND FLOOR | Sqm | 3732.44 | 3732.44 | 20.16 | False | None | None | False | None | False | 75245.9904 | 0 |
2927491 | 96520 | None | RGU213 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. SECOND FLOOR | Nos | 1193.09 | 1193.09 | 18.0 | False | None | None | False | None | False | 21475.62 | 0 |
2927492 | 96520 | None | RGU214 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. SECOND FLOOR | Kg | 455.18 | 455.18 | 408.0 | False | None | None | False | None | False | 185713.44 | 0 |
2927493 | 96520 | None | RGU215 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineerincharge . Cost of aluminium snap beading shall be paid in basic item :With float glass panes of 4.0 mm thickness weight not less than 10kg Sqm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. SECOND FLOOR | Sqm | 1058.15 | 1058.15 | 20.4 | False | None | None | False | None | False | 21586.26 | 0 |
2927494 | 96520 | None | RGU216 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass stainless steel screws etc. complete as per architectural drawings and directions of engineerincharge: Prelaminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. SECOND FLOOR | Sqm | 960.69 | 960.69 | 20.4 | False | None | None | False | None | False | 19598.076 | 0 |
2927495 | 96520 | None | RGU217 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 345.93 | 345.93 | 2244.4 | False | None | None | False | None | False | 776405.292 | 0 |
2927496 | 96520 | None | RGU218 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside SECOND FLOOR | Sqm | 334.15 | 334.15 | 1923.48 | False | None | None | False | None | False | 642730.842 | 0 |
2927497 | 96520 | None | RGU219 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. SECOND FLOOR | Sqm | 107.1 | 107.1 | 4167.88 | False | None | None | False | None | False | 446379.948 | 0 |
2927498 | 96520 | None | RGU220 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside SECOND FLOOR | Sqm | 373.78 | 373.78 | 2055.72 | False | None | None | False | None | False | 768387.0216 | 0 |
2927499 | 96520 | None | RGU221 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brickstone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineerincharge. SECOND FLOOR | Sqm | 379.13 | 379.13 | 118.15 | False | None | None | False | None | False | 44794.2095 | 0 |
2927500 | 96520 | None | RGU222 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide SECOND FLOOR | Rmtr | 40.7 | 40.7 | 4207.8 | False | None | None | False | None | False | 171257.46 | 0 |
2927501 | 96520 | None | RGU223 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. SECOND FLOOR | Rmtr | 55.69 | 55.69 | 942.56 | False | None | None | False | None | False | 52491.1664 | 0 |
2927502 | 96520 | None | RGU224 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm SECOND FLOOR | Sqm | 1258.43 | 1258.43 | 964.6 | False | None | None | False | None | False | 1213881.578 | 0 |
2927503 | 96520 | None | RGU225 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. SECOND FLOOR | Sqm | 3054.49 | 3054.49 | 362.47 | False | None | None | False | None | False | 1107160.9903 | 0 |
2927504 | 96520 | None | RGU226 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. SECOND FLOOR | Sqm | 5706.29 | 5706.29 | 131.93 | False | None | None | False | None | False | 752830.8397 | 0 |
2927505 | 96520 | None | RGU227 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately .Size of Tile 600x600 mm SECOND FLOOR | Sqm | 1420.15 | 1420.15 | 588.14 | False | None | None | False | None | False | 835247.021 | 0 |
2927506 | 96520 | None | RGU228 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade 0.10 kg of hardener and 0.20 kg of resin per kg , including filling grouting and finishing complete as per direction of Engineerincharge..Size of Tile 600x600 mm SECOND FLOOR | Sqm | 223.84 | 223.84 | 588.14 | False | None | None | False | None | False | 131649.2576 | 0 |
2927507 | 96520 | None | RGU229 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete SECOND FLOOR | Sqm | 3597.49 | 3597.49 | 15.45 | False | None | None | False | None | False | 55581.2205 | 0 |
2927508 | 96520 | None | RGU230 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 315.95 | 315.95 | 244.52 | False | None | None | False | None | False | 77256.094 | 0 |
2927509 | 96520 | None | RGU231 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kgbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis SECOND FLOOR | Sqm | 658.67 | 658.67 | 97.06 | False | None | None | False | None | False | 63930.5102 | 0 |
2927510 | 96520 | None | RGU232 | Providing and laying cinder concrete in cement 1:15 1 cement : 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. SECOND FLOOR | Cum | 2160.21 | 2160.21 | 42.07 | False | None | None | False | None | False | 90880.0347 | 0 |
2927511 | 96520 | None | RGU233 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick ness to be specified by the manufacturer , of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand , jointing with grey cement slurry at 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete. SECOND FLOOR | Sqm | 952.12 | 952.12 | 61.46 | False | None | None | False | None | False | 58517.2952 | 0 |
2927512 | 96520 | None | RGU234 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SECOND FLOOR | Sqm | 1551.88 | 1551.88 | 229.07 | False | None | None | False | None | False | 355489.1516 | 0 |
2927513 | 96520 | None | RGU235 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand , joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 SECOND FLOOR | Sqm | 4216.53 | 4216.53 | 152.06 | False | None | None | False | None | False | 641165.5518 | 0 |
2927514 | 96520 | None | RGU236 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineerin charge and finished smooth. SECOND FLOOR | Sqm | 2987.02 | 2987.02 | 2.7 | False | None | None | False | None | False | 8064.954 | 0 |
2927515 | 96520 | None | RGU237 | Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, ic fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. SECOND FLOOR | Kgs | 605.12 | 605.12 | 559.04 | False | None | None | False | None | False | 338286.2848 | 0 |
2927516 | 96520 | None | RGU238 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge SECOND FLOOR | Sqm | 117.81 | 117.81 | 4286.03 | False | None | None | False | None | False | 504937.1943 | 0 |
2927517 | 96520 | None | RGU239 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 167.08 | 167.08 | 1233.43 | False | None | None | False | None | False | 206081.4844 | 0 |
2927518 | 96520 | None | RGU240 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 303.09 | 303.09 | 822.29 | False | None | None | False | None | False | 249227.8761 | 0 |
2927519 | 96520 | None | RGU241 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 53.55 | 53.55 | 89.28 | False | None | None | False | None | False | 4780.944 | 0 |
2927520 | 96520 | None | RGU242 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 123.17 | 123.17 | 89.28 | False | None | None | False | None | False | 10996.6176 | 0 |
2927521 | 96520 | None | RGU243 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. SECOND FLOOR | Sqm | 56.76 | 56.76 | 129.02 | False | None | None | False | None | False | 7323.1752 | 0 |
2927522 | 96520 | None | RGU244 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. SECOND FLOOR | Sqm | 725.07 | 725.07 | 129.02 | False | None | None | False | None | False | 93548.5314 | 0 |
2927523 | 96520 | None | RGU245 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. SECOND FLOOR | Kg | 157.44 | 157.44 | 1298.7 | False | None | None | False | None | False | 204467.328 | 0 |
2927524 | 96520 | None | RGU246 | Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account .The weight of aluminium extruded section shall be taken for purpose of payment. SECOND FLOOR | Kg | 435.9 | 435.9 | 562.77 | False | None | None | False | None | False | 245311.443 | 0 |
2927525 | 96520 | None | RGU247 | Providing, assembling and supplying vision glass panels IGUs comprising of hermeticallysealed 612 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal structural silicone sealant etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2 For payment, only the actual area of glass on face 1 of the glass panels excluding the areas of the grooves and weather silicone sealant provided and fixed in position, shall be measured in m2. i Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance VLT of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient 0.250.28 and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. SECOND FLOOR | Sqm | 3259.05 | 3259.05 | 86.58 | False | None | None | False | None | False | 282168.549 | 0 |
2927526 | 96520 | None | RGU248 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. SECOND FLOOR | Kg | 484.09 | 484.09 | 141.85 | False | None | None | False | None | False | 68668.1665 | 0 |
2927527 | 96520 | None | RGU249 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS THIRD FLOOR | Cum | 12882.72 | 12882.72 | 134.08 | False | None | None | False | None | False | 1727315.0976 | 0 |
2927528 | 96520 | None | RGU250 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS THIRD FLOOR | Cum | 12124.91 | 12124.91 | 151.66 | False | None | None | False | None | False | 1838863.8506 | 0 |
2927529 | 96520 | None | RGU251 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB THIRD FLOOR | Cum | 11367.11 | 11367.11 | 215.67 | False | None | None | False | None | False | 2451544.6137 | 0 |
2927530 | 96520 | None | RGU252 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC STAIRCASE THIRD FLOOR | Cum | 11367.11 | 11367.11 | 21.04 | False | None | None | False | None | False | 239163.9944 | 0 |
2927531 | 96520 | None | RGU253 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. LINTELS THIRD FLOOR | Cum | 12124.91 | 12124.91 | 22.76 | False | None | None | False | None | False | 275962.9516 | 0 |
2927532 | 96520 | None | RGU254 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork THIRD FLOOR | Cum | 10397.0 | 10397.0 | 17.49 | False | None | None | False | None | False | 181843.53 | 0 |
2927533 | 96520 | None | RGU255 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with Cement Epoxy THIRD FLOOR | No | 220.63 | 220.63 | 100.0 | False | None | None | False | None | False | 22063.0 | 0 |
2927534 | 96520 | None | RGU256 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. THIRD FLOOR | Tonne | 96747.75 | 96747.75 | 86.88 | False | None | None | False | None | False | 8405444.52 | 0 |
2927535 | 96520 | None | RGU257 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS THIRD FLOOR | Rmtr | 33.0 | 33.0 | 191.0 | False | None | None | False | None | False | 6303.0 | 0 |
2927536 | 96520 | None | RGU258 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200 mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. THIRD FLOOR | Cum | 8628.21 | 8628.21 | 339.07 | False | None | None | False | None | False | 2925567.1647 | 0 |
2927537 | 96520 | None | RGU259 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level in cement mortar 1:4 1 cement : 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. THIRD FLOOR | Cum | 9254.4 | 9254.4 | 65.48 | False | None | None | False | None | False | 605978.112 | 0 |
2927538 | 96520 | None | RGU260 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. THIRD FLOOR | Cum | 106868.42 | 106868.42 | 1.28 | False | None | None | False | None | False | 136791.5776 | 0 |
2927539 | 96520 | None | RGU261 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. THIRD FLOOR | Nos | 1098.8 | 1098.8 | 16.0 | False | None | None | False | None | False | 17580.8 | 0 |
2927540 | 96520 | None | RGU262 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm THIRD FLOOR | Nos | 7029.75 | 7029.75 | 32.0 | False | None | None | False | None | False | 224952.0 | 0 |
2927541 | 96520 | None | RGU263 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm THIRD FLOOR | Nos | 405.56 | 405.56 | 16.0 | False | None | None | False | None | False | 6488.96 | 0 |
2927542 | 96520 | None | RGU264 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm THIRD FLOOR | Nos | 162.23 | 162.23 | 32.0 | False | None | None | False | None | False | 5191.36 | 0 |
2927543 | 96520 | None | RGU265 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm THIRD FLOOR | Nos | 75.71 | 75.71 | 64.0 | False | None | None | False | None | False | 4845.44 | 0 |
2927544 | 96520 | None | RGU266 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm THIRD FLOOR | Nos | 108.15 | 108.15 | 16.0 | False | None | None | False | None | False | 1730.4 | 0 |
2927545 | 96520 | None | RGU267 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. THIRD FLOOR | Nos | 1137.74 | 1137.74 | 16.0 | False | None | None | False | None | False | 18203.84 | 0 |
2927546 | 96520 | None | RGU268 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm THIRD FLOOR | Nos | 64.89 | 64.89 | 96.0 | False | None | None | False | None | False | 6229.44 | 0 |
2927547 | 96520 | None | RGU269 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. THIRD FLOOR | Sqm | 4901.36 | 4901.36 | 49.2 | False | None | None | False | None | False | 241146.912 | 0 |
2927548 | 96520 | None | RGU270 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineerincharge Door handle, lock and stopper etc. to be paid separately including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. THIRD FLOOR | Sqm | 5106.84 | 5106.84 | 17.4 | False | None | None | False | None | False | 88859.016 | 0 |
2927549 | 96520 | None | RGU271 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made THIRD FLOOR | Sqm | 7282.82 | 7282.82 | 81.0 | False | None | None | False | None | False | 589908.42 | 0 |
2927550 | 96520 | None | RGU272 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made THIRD FLOOR | Sqm | 6185.1 | 6185.1 | 8.28 | False | None | None | False | None | False | 51212.628 | 0 |
2927551 | 96520 | None | RGU273 | Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made THIRD FLOOR | Sqm | 5829.29 | 5829.29 | 28.86 | False | None | None | False | None | False | 168233.3094 | 0 |
2927552 | 96520 | None | RGU274 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding THIRD FLOOR | Kg | 181.69 | 181.69 | 1874.88 | False | None | None | False | None | False | 340646.9472 | 0 |
2927553 | 96520 | None | RGU275 | Providing and fixing factory made single extruded WPC Wood Polymer Composite solid doorwindowClerestory windows and other Frames Chowkhat comprising of virgin PVC polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibres wood powderrice husk wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kgm3, screw withdrawal strength of 2200 N Face and 1100 N Edge , minimum compressive strength of 58 Nmm2 , modulus of elasticity 900 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixed in position with M.S hold fastlugsSS dash fasteners of required dia and length complete as per direction of EngineerInCharge. Fixtures shall be paid for separately Size 62 x 100mm THIRD FLOOR | Rmtr | 759.21 | 759.21 | 60.0 | False | None | None | False | None | False | 45552.6 | 0 |
2927554 | 96520 | None | RGU276 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibers wood powderrice huskwheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kgm3 and screw withdrawal strength of 1800 N Face and 900 N Edge , minimum compressive strength of 50 Nmm2 , modulus of elasticity 850 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. Cost of Fixtures to be paid separately 30 mm thickness THIRD FLOOR | Sqm | 3769.03 | 3769.03 | 20.16 | False | None | None | False | None | False | 75983.6448 | 0 |
2927555 | 96520 | None | RGU277 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. THIRD FLOOR | Nos | 1204.79 | 1204.79 | 16.0 | False | None | None | False | None | False | 19276.64 | 0 |
2927556 | 96520 | None | RGU278 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. THIRD FLOOR | Kg | 459.64 | 459.64 | 408.0 | False | None | None | False | None | False | 187533.12 | 0 |
2927557 | 96520 | None | RGU279 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineerincharge . Cost of aluminium snap beading shall be paid in basic item :With float glass panes of 4.0 mm thickness weight not less than 10kg Sqm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. THIRD FLOOR | Sqm | 1068.52 | 1068.52 | 20.4 | False | None | None | False | None | False | 21797.808 | 0 |
2927558 | 96520 | None | RGU280 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass stainless steel screws etc. complete as per architectural drawings and directions of engineerincharge: Prelaminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. THIRD FLOOR | Sqm | 970.11 | 970.11 | 20.4 | False | None | None | False | None | False | 19790.244 | 0 |
2927559 | 96520 | None | RGU281 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 349.32 | 349.32 | 2244.4 | False | None | None | False | None | False | 784013.808 | 0 |
2927560 | 96520 | None | RGU282 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside THIRD FLOOR | Sqm | 337.43 | 337.43 | 1865.17 | False | None | None | False | None | False | 629364.3131 | 0 |
2927561 | 96520 | None | RGU283 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. THIRD FLOOR | Sqm | 108.15 | 108.15 | 4109.57 | False | None | None | False | None | False | 444449.9955 | 0 |
2927562 | 96520 | None | RGU284 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside THIRD FLOOR | Sqm | 377.44 | 377.44 | 2055.72 | False | None | None | False | None | False | 775910.9568 | 0 |
2927563 | 96520 | None | RGU285 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brickstone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineerincharge. THIRD FLOOR | Sqm | 382.85 | 382.85 | 118.15 | False | None | None | False | None | False | 45233.7275 | 0 |
2927564 | 96520 | None | RGU286 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide THIRD FLOOR | Rmtr | 41.1 | 41.1 | 4155.6 | False | None | None | False | None | False | 170795.16 | 0 |
2927565 | 96520 | None | RGU287 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. THIRD FLOOR | Rmtr | 56.24 | 56.24 | 942.56 | False | None | None | False | None | False | 53009.5744 | 0 |
2927566 | 96520 | None | RGU288 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm THIRD FLOOR | Sqm | 1270.76 | 1270.76 | 975.32 | False | None | None | False | None | False | 1239397.6432 | 0 |
2927567 | 96520 | None | RGU289 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. THIRD FLOOR | Sqm | 3084.44 | 3084.44 | 362.47 | False | None | None | False | None | False | 1118016.9668 | 0 |
2927568 | 96520 | None | RGU290 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. THIRD FLOOR | Sqm | 5762.23 | 5762.23 | 131.93 | False | None | None | False | None | False | 760211.0039 | 0 |
2927569 | 96520 | None | RGU291 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately .Size of Tile 600x600 mm THIRD FLOOR | Sqm | 1434.07 | 1434.07 | 603.92 | False | None | None | False | None | False | 866063.5544 | 0 |
2927570 | 96520 | None | RGU292 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade 0.10 kg of hardener and 0.20 kg of resin per kg , including filling grouting and finishing complete as per direction of Engineerincharge..Size of Tile 600x600 mm THIRD FLOOR | Sqm | 226.03 | 226.03 | 603.92 | False | None | None | False | None | False | 136504.0376 | 0 |
2927571 | 96520 | None | RGU293 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete THIRD FLOOR | Sqm | 3632.76 | 3632.76 | 15.45 | False | None | None | False | None | False | 56126.142 | 0 |
2927572 | 96520 | None | RGU294 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 319.04 | 319.04 | 245.09 | False | None | None | False | None | False | 78193.5136 | 0 |
2927573 | 96520 | None | RGU295 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kgbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis THIRD FLOOR | Sqm | 665.12 | 665.12 | 97.28 | False | None | None | False | None | False | 64702.8736 | 0 |
2927574 | 96520 | None | RGU296 | Providing and laying cinder concrete in cement 1:15 1 cement : 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. THIRD FLOOR | Cum | 2181.39 | 2181.39 | 42.2 | False | None | None | False | None | False | 92054.658 | 0 |
2927575 | 96520 | None | RGU297 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick ness to be specified by the manufacturer , of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand , jointing with grey cement slurry at 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete. THIRD FLOOR | Sqm | 961.45 | 961.45 | 61.59 | False | None | None | False | None | False | 59215.7055 | 0 |
2927576 | 96520 | None | RGU298 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. THIRD FLOOR | Sqm | 1567.09 | 1567.09 | 229.64 | False | None | None | False | None | False | 359866.5476 | 0 |
2927577 | 96520 | None | RGU299 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand , joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 THIRD FLOOR | Sqm | 4257.87 | 4257.87 | 159.38 | False | None | None | False | None | False | 678619.3206 | 0 |
2927578 | 96520 | None | RGU300 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineerin charge and finished smooth. THIRD FLOOR | Sqm | 3016.3 | 3016.3 | 2.7 | False | None | None | False | None | False | 8144.01 | 0 |
2927579 | 96520 | None | RGU301 | Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, ic fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. THIRD FLOOR | Kgs | 611.05 | 611.05 | 559.04 | False | None | None | False | None | False | 341601.392 | 0 |
2927580 | 96520 | None | RGU302 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge THIRD FLOOR | Sqm | 118.97 | 118.97 | 4227.72 | False | None | None | False | None | False | 502971.8484 | 0 |
2927581 | 96520 | None | RGU303 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 168.71 | 168.71 | 1233.43 | False | None | None | False | None | False | 208091.9753 | 0 |
2927582 | 96520 | None | RGU304 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 306.06 | 306.06 | 822.29 | False | None | None | False | None | False | 251670.0774 | 0 |
2927583 | 96520 | None | RGU305 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 54.08 | 54.08 | 89.28 | False | None | None | False | None | False | 4828.2624 | 0 |
2927584 | 96520 | None | RGU306 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 124.37 | 124.37 | 89.28 | False | None | None | False | None | False | 11103.7536 | 0 |
2927585 | 96520 | None | RGU307 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. THIRD FLOOR | Sqm | 57.32 | 57.32 | 118.08 | False | None | None | False | None | False | 6768.3456 | 0 |
2927586 | 96520 | None | RGU308 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. THIRD FLOOR | Sqm | 732.18 | 732.18 | 118.08 | False | None | None | False | None | False | 86455.8144 | 0 |
2927587 | 96520 | None | RGU309 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. THIRD FLOOR | Kg | 158.98 | 158.98 | 1298.7 | False | None | None | False | None | False | 206467.326 | 0 |
2927588 | 96520 | None | RGU310 | Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account .The weight of aluminium extruded section shall be taken for purpose of payment. THIRD FLOOR | Kg | 440.17 | 440.17 | 562.77 | False | None | None | False | None | False | 247714.4709 | 0 |
2927589 | 96520 | None | RGU311 | Providing, assembling and supplying vision glass panels IGUs comprising of hermeticallysealed 612 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal structural silicone sealant etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2 For payment, only the actual area of glass on face 1 of the glass panels excluding the areas of the grooves and weather silicone sealant provided and fixed in position, shall be measured in m2. i Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance VLT of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient 0.250.28 and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. THIRD FLOOR | Sqm | 3291.0 | 3291.0 | 86.58 | False | None | None | False | None | False | 284934.78 | 0 |
2927590 | 96520 | None | RGU312 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. THIRD FLOOR | Kg | 488.84 | 488.84 | 140.4 | False | None | None | False | None | False | 68633.136 | 0 |
2927591 | 96520 | None | RGU313 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS FOURTH FLOOR | Cum | 13007.79 | 13007.79 | 134.08 | False | None | None | False | None | False | 1744084.4832 | 0 |
2927592 | 96520 | None | RGU314 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS FOURTH FLOOR | Cum | 12242.63 | 12242.63 | 154.89 | False | None | None | False | None | False | 1896260.9607 | 0 |
2927593 | 96520 | None | RGU315 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB FOURTH FLOOR | Cum | 11477.47 | 11477.47 | 223.57 | False | None | None | False | None | False | 2566017.9679 | 0 |
2927594 | 96520 | None | RGU316 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC STAIRCASE FOURTH FLOOR | Cum | 11477.47 | 11477.47 | 21.04 | False | None | None | False | None | False | 241485.9688 | 0 |
2927595 | 96520 | None | RGU317 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. LINTELS FOURTH FLOOR | Cum | 12242.63 | 12242.63 | 22.76 | False | None | None | False | None | False | 278642.2588 | 0 |
2927596 | 96520 | None | RGU318 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork FOURTH FLOOR | Cum | 10497.94 | 10497.94 | 17.49 | False | None | None | False | None | False | 183608.9706 | 0 |
2927597 | 96520 | None | RGU319 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with Cement Epoxy FOURTH FLOOR | No | 222.77 | 222.77 | 100.0 | False | None | None | False | None | False | 22277.0 | 0 |
2927598 | 96520 | None | RGU320 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FOURTH FLOOR | Tonne | 97687.04 | 97687.04 | 86.85 | False | None | None | False | None | False | 8484119.424 | 0 |
2927599 | 96520 | None | RGU321 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS FOURTH FLOOR | Rmtr | 33.0 | 33.0 | 191.0 | False | None | None | False | None | False | 6303.0 | 0 |
2927600 | 96520 | None | RGU322 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. FOURTH FLOOR | Cum | 8711.98 | 8711.98 | 339.07 | False | None | None | False | None | False | 2953971.0586 | 0 |
2927601 | 96520 | None | RGU323 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level in cement mortar 1:4 1 cement : 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. FOURTH FLOOR | Cum | 9344.24 | 9344.24 | 66.86 | False | None | None | False | None | False | 624755.8864 | 0 |
2927602 | 96520 | None | RGU324 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. FOURTH FLOOR | Cum | 107905.98 | 107905.98 | 1.28 | False | None | None | False | None | False | 138119.6544 | 0 |
2927603 | 96520 | None | RGU325 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FOURTH FLOOR | Nos | 1109.47 | 1109.47 | 16.0 | False | None | None | False | None | False | 17751.52 | 0 |
2927604 | 96520 | None | RGU326 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm FOURTH FLOOR | Nos | 7098.0 | 7098.0 | 32.0 | False | None | None | False | None | False | 227136.0 | 0 |
2927605 | 96520 | None | RGU327 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm FOURTH FLOOR | Nos | 409.5 | 409.5 | 16.0 | False | None | None | False | None | False | 6552.0 | 0 |
2927606 | 96520 | None | RGU328 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm FOURTH FLOOR | Nos | 163.8 | 163.8 | 32.0 | False | None | None | False | None | False | 5241.6 | 0 |
2927607 | 96520 | None | RGU329 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm FOURTH FLOOR | Nos | 76.44 | 76.44 | 64.0 | False | None | None | False | None | False | 4892.16 | 0 |
2927608 | 96520 | None | RGU330 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm FOURTH FLOOR | Nos | 109.2 | 109.2 | 16.0 | False | None | None | False | None | False | 1747.2 | 0 |
2927609 | 96520 | None | RGU331 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FOURTH FLOOR | Nos | 1148.78 | 1148.78 | 16.0 | False | None | None | False | None | False | 18380.48 | 0 |
2927610 | 96520 | None | RGU332 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FOURTH FLOOR | Nos | 65.52 | 65.52 | 96.0 | False | None | None | False | None | False | 6289.92 | 0 |
2927611 | 96520 | None | RGU333 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. FOURTH FLOOR | Sqm | 4948.94 | 4948.94 | 49.2 | False | None | None | False | None | False | 243487.848 | 0 |
2927612 | 96520 | None | RGU334 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineerincharge Door handle, lock and stopper etc. to be paid separately including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FOURTH FLOOR | Sqm | 5156.42 | 5156.42 | 17.4 | False | None | None | False | None | False | 89721.708 | 0 |
2927613 | 96520 | None | RGU335 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FOURTH FLOOR | Sqm | 7353.53 | 7353.53 | 81.0 | False | None | None | False | None | False | 595635.93 | 0 |
2927614 | 96520 | None | RGU336 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FOURTH FLOOR | Sqm | 6245.15 | 6245.15 | 8.28 | False | None | None | False | None | False | 51709.842 | 0 |
2927615 | 96520 | None | RGU337 | Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FOURTH FLOOR | Sqm | 5885.88 | 5885.88 | 28.86 | False | None | None | False | None | False | 169866.4968 | 0 |
2927616 | 96520 | None | RGU338 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FOURTH FLOOR | Kg | 183.46 | 183.46 | 1874.88 | False | None | None | False | None | False | 343965.4848 | 0 |
2927617 | 96520 | None | RGU339 | Providing and fixing factory made single extruded WPC Wood Polymer Composite solid doorwindowClerestory windows and other Frames Chowkhat comprising of virgin PVC polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibres wood powderrice husk wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kgm3, screw withdrawal strength of 2200 N Face and 1100 N Edge , minimum compressive strength of 58 Nmm2 , modulus of elasticity 900 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixed in position with M.S hold fastlugsSS dash fasteners of required dia and length complete as per direction of EngineerInCharge. Fixtures shall be paid for separately Size 62 x 100mm FOURTH FLOOR | Rmtr | 766.58 | 766.58 | 60.0 | False | None | None | False | None | False | 45994.8 | 0 |
2927618 | 96520 | None | RGU340 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibers wood powderrice huskwheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kgm3 and screw withdrawal strength of 1800 N Face and 900 N Edge , minimum compressive strength of 50 Nmm2 , modulus of elasticity 850 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. Cost of Fixtures to be paid separately 30 mm thickness FOURTH FLOOR | Sqm | 3805.62 | 3805.62 | 20.16 | False | None | None | False | None | False | 76721.2992 | 0 |
2927619 | 96520 | None | RGU341 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. FOURTH FLOOR | Nos | 1216.49 | 1216.49 | 16.0 | False | None | None | False | None | False | 19463.84 | 0 |
2927620 | 96520 | None | RGU342 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. FOURTH FLOOR | Kg | 464.1 | 464.1 | 408.0 | False | None | None | False | None | False | 189352.8 | 0 |
2927621 | 96520 | None | RGU343 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineerincharge . Cost of aluminium snap beading shall be paid in basic item :With float glass panes of 4.0 mm thickness weight not less than 10kg Sqm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FOURTH FLOOR | Sqm | 1078.9 | 1078.9 | 20.4 | False | None | None | False | None | False | 22009.56 | 0 |
2927622 | 96520 | None | RGU344 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass stainless steel screws etc. complete as per architectural drawings and directions of engineerincharge: Prelaminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. FOURTH FLOOR | Sqm | 979.52 | 979.52 | 20.4 | False | None | None | False | None | False | 19982.208 | 0 |
2927623 | 96520 | None | RGU345 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 352.72 | 352.72 | 2327.21 | False | None | None | False | None | False | 820853.5112 | 0 |
2927624 | 96520 | None | RGU346 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside FOURTH FLOOR | Sqm | 340.7 | 340.7 | 1863.79 | False | None | None | False | None | False | 634993.253 | 0 |
2927625 | 96520 | None | RGU347 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FOURTH FLOOR | Sqm | 109.2 | 109.2 | 4191.0 | False | None | None | False | None | False | 457657.2 | 0 |
2927626 | 96520 | None | RGU348 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside FOURTH FLOOR | Sqm | 381.11 | 381.11 | 2083.32 | False | None | None | False | None | False | 793974.0852 | 0 |
2927627 | 96520 | None | RGU349 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brickstone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineerincharge. FOURTH FLOOR | Sqm | 386.57 | 386.57 | 118.15 | False | None | None | False | None | False | 45673.2455 | 0 |
2927628 | 96520 | None | RGU350 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide FOURTH FLOOR | Rmtr | 41.5 | 41.5 | 4155.6 | False | None | None | False | None | False | 172457.4 | 0 |
2927629 | 96520 | None | RGU351 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. FOURTH FLOOR | Rmtr | 56.78 | 56.78 | 942.56 | False | None | None | False | None | False | 53518.5568 | 0 |
2927630 | 96520 | None | RGU352 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm FOURTH FLOOR | Sqm | 1283.1 | 1283.1 | 974.2 | False | None | None | False | None | False | 1249996.02 | 0 |
2927631 | 96520 | None | RGU353 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FOURTH FLOOR | Sqm | 3114.38 | 3114.38 | 362.47 | False | None | None | False | None | False | 1128869.3186 | 0 |
2927632 | 96520 | None | RGU354 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. FOURTH FLOOR | Sqm | 5650.34 | 5650.34 | 131.93 | False | None | None | False | None | False | 745449.3562 | 0 |
2927633 | 96520 | None | RGU355 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately .Size of Tile 600x600 mm FOURTH FLOOR | Sqm | 1447.99 | 1447.99 | 603.92 | False | None | None | False | None | False | 874470.1208 | 0 |
2927634 | 96520 | None | RGU356 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade 0.10 kg of hardener and 0.20 kg of resin per kg , including filling grouting and finishing complete as per direction of Engineerincharge..Size of Tile 600x600 mm FOURTH FLOOR | Sqm | 228.23 | 228.23 | 603.92 | False | None | None | False | None | False | 137832.6616 | 0 |
2927635 | 96520 | None | RGU357 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete FOURTH FLOOR | Sqm | 3668.03 | 3668.03 | 15.45 | False | None | None | False | None | False | 56671.0635 | 0 |
2927636 | 96520 | None | RGU358 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 322.14 | 322.14 | 245.09 | False | None | None | False | None | False | 78953.2926 | 0 |
2927637 | 96520 | None | RGU359 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kgbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis FOURTH FLOOR | Sqm | 671.58 | 671.58 | 97.28 | False | None | None | False | None | False | 65331.3024 | 0 |
2927638 | 96520 | None | RGU360 | Providing and laying cinder concrete in cement 1:15 1 cement : 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FOURTH FLOOR | Cum | 2202.56 | 2202.56 | 42.2 | False | None | None | False | None | False | 92948.032 | 0 |
2927639 | 96520 | None | RGU361 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick ness to be specified by the manufacturer , of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand , jointing with grey cement slurry at 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete. FOURTH FLOOR | Sqm | 970.79 | 970.79 | 61.59 | False | None | None | False | None | False | 59790.9561 | 0 |
2927640 | 96520 | None | RGU362 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FOURTH FLOOR | Sqm | 1582.31 | 1582.31 | 229.64 | False | None | None | False | None | False | 363361.6684 | 0 |
2927641 | 96520 | None | RGU363 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand , joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 FOURTH FLOOR | Sqm | 4299.2 | 4299.2 | 159.38 | False | None | None | False | None | False | 685206.496 | 0 |
2927642 | 96520 | None | RGU364 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineerin charge and finished smooth. FOURTH FLOOR | Sqm | 3045.59 | 3045.59 | 2.7 | False | None | None | False | None | False | 8223.093 | 0 |
2927643 | 96520 | None | RGU365 | Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, ic fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FOURTH FLOOR | Kgs | 616.98 | 616.98 | 559.04 | False | None | None | False | None | False | 344916.4992 | 0 |
2927644 | 96520 | None | RGU366 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge FOURTH FLOOR | Sqm | 120.12 | 120.12 | 4309.15 | False | None | None | False | None | False | 517615.098 | 0 |
2927645 | 96520 | None | RGU367 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 170.35 | 170.35 | 1249.99 | False | None | None | False | None | False | 212935.7965 | 0 |
2927646 | 96520 | None | RGU368 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 309.04 | 309.04 | 833.33 | False | None | None | False | None | False | 257532.3032 | 0 |
2927647 | 96520 | None | RGU369 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 54.6 | 54.6 | 89.28 | False | None | None | False | None | False | 4874.688 | 0 |
2927648 | 96520 | None | RGU370 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 125.58 | 125.58 | 89.28 | False | None | None | False | None | False | 11211.7824 | 0 |
2927649 | 96520 | None | RGU371 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FOURTH FLOOR | Sqm | 57.88 | 57.88 | 118.08 | False | None | None | False | None | False | 6834.4704 | 0 |
2927650 | 96520 | None | RGU372 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. FOURTH FLOOR | Sqm | 739.28 | 739.28 | 118.08 | False | None | None | False | None | False | 87294.1824 | 0 |
2927651 | 96520 | None | RGU373 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FOURTH FLOOR | Kg | 160.52 | 160.52 | 1298.7 | False | None | None | False | None | False | 208467.324 | 0 |
2927652 | 96520 | None | RGU374 | Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account .The weight of aluminium extruded section shall be taken for purpose of payment. FOURTH FLOOR | Kg | 444.44 | 444.44 | 562.77 | False | None | None | False | None | False | 250117.4988 | 0 |
2927653 | 96520 | None | RGU375 | Providing, assembling and supplying vision glass panels IGUs comprising of hermeticallysealed 612 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal structural silicone sealant etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2 For payment, only the actual area of glass on face 1 of the glass panels excluding the areas of the grooves and weather silicone sealant provided and fixed in position, shall be measured in m2. i Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance VLT of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient 0.250.28 and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. FOURTH FLOOR | Sqm | 3322.96 | 3322.96 | 86.58 | False | None | None | False | None | False | 287701.8768 | 0 |
2927654 | 96520 | None | RGU376 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. FOURTH FLOOR | Kg | 493.58 | 493.58 | 142.25 | False | None | None | False | None | False | 70211.755 | 0 |
2927655 | 96520 | None | RGU377 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS FIFTH FLOOR | Cum | 13132.87 | 13132.87 | 134.08 | False | None | None | False | None | False | 1760855.2096 | 0 |
2927656 | 96520 | None | RGU378 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS FIFTH FLOOR | Cum | 12360.35 | 12360.35 | 151.66 | False | None | None | False | None | False | 1874570.681 | 0 |
2927657 | 96520 | None | RGU379 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB FIFTH FLOOR | Cum | 11587.83 | 11587.83 | 217.74 | False | None | None | False | None | False | 2523134.1042 | 0 |
2927658 | 96520 | None | RGU380 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC STAIRCASE FIFTH FLOOR | Cum | 11587.83 | 11587.83 | 7.7 | False | None | None | False | None | False | 89226.291 | 0 |
2927659 | 96520 | None | RGU381 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. LINTELS FIFTH FLOOR | Cum | 12360.35 | 12360.35 | 22.27 | False | None | None | False | None | False | 275264.9945 | 0 |
2927660 | 96520 | None | RGU382 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, The cost includes Formwork all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other. The cost of steel reinforcement, dowel bars and to be paid separately Mix 1:2:4 M15 Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork FIFTH FLOOR | Cum | 10598.88 | 10598.88 | 17.25 | False | None | None | False | None | False | 182830.68 | 0 |
2927661 | 96520 | None | RGU383 | Providing and inserting nipples with approved fixing compound after drilling holes for grouting as per Technical Specifications including subsequent cuttingremoval and sealing of the hole as necessary of nipples after completion of grouting with Cement Epoxy FIFTH FLOOR | No | 224.91 | 224.91 | 100.0 | False | None | None | False | None | False | 22491.0 | 0 |
2927662 | 96520 | None | RGU384 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. FIFTH FLOOR | Tonne | 98626.34 | 98626.34 | 81.9 | False | None | None | False | None | False | 8077497.246 | 0 |
2927663 | 96520 | None | RGU385 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS FIFTH FLOOR | Rmtr | 33.0 | 33.0 | 191.0 | False | None | None | False | None | False | 6303.0 | 0 |
2927664 | 96520 | None | RGU386 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. FIFTH FLOOR | Cum | 8795.75 | 8795.75 | 334.08 | False | None | None | False | None | False | 2938484.16 | 0 |
2927665 | 96520 | None | RGU387 | Providing and laying Autoclaved Aerated Cement blocks masonry with 100 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level in cement mortar 1:4 1 cement : 4 coarse sand including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. FIFTH FLOOR | Cum | 9434.09 | 9434.09 | 22.53 | False | None | None | False | None | False | 212550.0477 | 0 |
2927666 | 96520 | None | RGU388 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. FIFTH FLOOR | Cum | 108943.54 | 108943.54 | 1.19 | False | None | None | False | None | False | 129642.8126 | 0 |
2927667 | 96520 | None | RGU389 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FIFTH FLOOR | Nos | 1120.14 | 1120.14 | 15.0 | False | None | None | False | None | False | 16802.1 | 0 |
2927668 | 96520 | None | RGU390 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm FIFTH FLOOR | Nos | 7166.25 | 7166.25 | 30.0 | False | None | None | False | None | False | 214987.5 | 0 |
2927669 | 96520 | None | RGU391 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm FIFTH FLOOR | Nos | 413.44 | 413.44 | 15.0 | False | None | None | False | None | False | 6201.6 | 0 |
2927670 | 96520 | None | RGU392 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm FIFTH FLOOR | Nos | 165.38 | 165.38 | 30.0 | False | None | None | False | None | False | 4961.4 | 0 |
2927671 | 96520 | None | RGU393 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm FIFTH FLOOR | Nos | 77.18 | 77.18 | 60.0 | False | None | None | False | None | False | 4630.8 | 0 |
2927672 | 96520 | None | RGU394 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm FIFTH FLOOR | Nos | 110.25 | 110.25 | 15.0 | False | None | None | False | None | False | 1653.75 | 0 |
2927673 | 96520 | None | RGU395 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIFTH FLOOR | Nos | 1159.83 | 1159.83 | 15.0 | False | None | None | False | None | False | 17397.45 | 0 |
2927674 | 96520 | None | RGU396 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIFTH FLOOR | Nos | 66.15 | 66.15 | 90.0 | False | None | None | False | None | False | 5953.5 | 0 |
2927675 | 96520 | None | RGU397 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. FIFTH FLOOR | Sqm | 4996.53 | 4996.53 | 45.6 | False | None | None | False | None | False | 227841.768 | 0 |
2927676 | 96520 | None | RGU398 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top and bottom pivot and double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineerincharge Door handle, lock and stopper etc. to be paid separately including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FIFTH FLOOR | Sqm | 5206.01 | 5206.01 | 4.8 | False | None | None | False | None | False | 24988.848 | 0 |
2927677 | 96520 | None | RGU399 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FIFTH FLOOR | Sqm | 7424.24 | 7424.24 | 81.0 | False | None | None | False | None | False | 601363.44 | 0 |
2927678 | 96520 | None | RGU400 | Providing and fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FIFTH FLOOR | Sqm | 6305.2 | 6305.2 | 8.28 | False | None | None | False | None | False | 52207.056 | 0 |
2927679 | 96520 | None | RGU401 | Providing and fixing of 2track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+0.2 mm. Maximum possible size 1519mm x 1519mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made FIFTH FLOOR | Sqm | 5942.48 | 5942.48 | 28.86 | False | None | None | False | None | False | 171499.9728 | 0 |
2927680 | 96520 | None | RGU402 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIFTH FLOOR | Kg | 185.22 | 185.22 | 1874.88 | False | None | None | False | None | False | 347265.2736 | 0 |
2927681 | 96520 | None | RGU403 | Providing and fixing factory made single extruded WPC Wood Polymer Composite solid doorwindowClerestory windows and other Frames Chowkhat comprising of virgin PVC polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibres wood powderrice husk wheat husk and non toxic additives maximum toxicity index of 12 for 100 g fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kgm3, screw withdrawal strength of 2200 N Face and 1100 N Edge , minimum compressive strength of 58 Nmm2 , modulus of elasticity 900 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixed in position with M.S hold fastlugsSS dash fasteners of required dia and length complete as per direction of EngineerInCharge. Fixtures shall be paid for separately Size 62 x 100mm FIFTH FLOOR | Rmtr | 773.96 | 773.96 | 60.0 | False | None | None | False | None | False | 46437.6 | 0 |
2927682 | 96520 | None | RGU404 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC Wood PolymerComposite solid plain flush door shutter of required size comprising of virgin polymer of K value 5860 Suspension Grade , calcium carbonate and natural fibers wood powderrice huskwheat husk and non toxic additives maximum toxicity index of 12 for 100 g having minimum density of 650 kgm3 and screw withdrawal strength of 1800 N Face and 900 N Edge , minimum compressive strength of 50 Nmm2 , modulus of elasticity 850 Nmm2 and resistance to spread of flame of Class A category with property of being termiteborer proof, watermoisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. Cost of Fixtures to be paid separately 30 mm thickness FIFTH FLOOR | Sqm | 3842.21 | 3842.21 | 20.16 | False | None | None | False | None | False | 77458.9536 | 0 |
2927683 | 96520 | None | RGU405 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. FIFTH FLOOR | Nos | 1228.19 | 1228.19 | 15.0 | False | None | None | False | None | False | 18422.85 | 0 |
2927684 | 96520 | None | RGU406 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. FIFTH FLOOR | Kg | 468.56 | 468.56 | 734.4 | False | None | None | False | None | False | 344110.464 | 0 |
2927685 | 96520 | None | RGU407 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber neoprene gasket etc. complete as per the architectural drawings and the directions of engineerincharge . Cost of aluminium snap beading shall be paid in basic item :With float glass panes of 4.0 mm thickness weight not less than 10kg Sqm including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FIFTH FLOOR | Sqm | 1089.27 | 1089.27 | 36.72 | False | None | None | False | None | False | 39997.9944 | 0 |
2927686 | 96520 | None | RGU408 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass stainless steel screws etc. complete as per architectural drawings and directions of engineerincharge: Prelaminated particle board with decorative lamination on one side and balancing lamination on other side including cost of materials, labour, usage charges of machinery complete as per specifications. FIFTH FLOOR | Sqm | 988.94 | 988.94 | 36.72 | False | None | None | False | None | False | 36313.8768 | 0 |
2927687 | 96520 | None | RGU409 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 356.11 | 356.11 | 2244.4 | False | None | None | False | None | False | 799253.284 | 0 |
2927688 | 96520 | None | RGU410 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside FIFTH FLOOR | Sqm | 343.98 | 343.98 | 1850.57 | False | None | None | False | None | False | 636559.0686 | 0 |
2927689 | 96520 | None | RGU411 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. FIFTH FLOOR | Sqm | 110.25 | 110.25 | 4094.97 | False | None | None | False | None | False | 451470.4425 | 0 |
2927690 | 96520 | None | RGU412 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside FIFTH FLOOR | Sqm | 384.77 | 384.77 | 1255.32 | False | None | None | False | None | False | 483009.4764 | 0 |
2927691 | 96520 | None | RGU413 | Providing 20 mm cement plaster of mix :1:4 1 cement: 4 fine sand to brickstone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc tions of Engineerincharge. FIFTH FLOOR | Sqm | 390.29 | 390.29 | 43.7 | False | None | None | False | None | False | 17055.673 | 0 |
2927692 | 96520 | None | RGU414 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide FIFTH FLOOR | Rmtr | 41.9 | 41.9 | 4100.7 | False | None | None | False | None | False | 171819.33 | 0 |
2927693 | 96520 | None | RGU415 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. FIFTH FLOOR | Rmtr | 57.33 | 57.33 | 942.56 | False | None | None | False | None | False | 54036.9648 | 0 |
2927694 | 96520 | None | RGU416 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm FIFTH FLOOR | Sqm | 1295.44 | 1295.44 | 973.37 | False | None | None | False | None | False | 1260942.4328 | 0 |
2927695 | 96520 | None | RGU417 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. FIFTH FLOOR | Sqm | 3144.33 | 3144.33 | 362.47 | False | None | None | False | None | False | 1139725.2951 | 0 |
2927696 | 96520 | None | RGU418 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. FIFTH FLOOR | Sqm | 5874.12 | 5874.12 | 43.45 | False | None | None | False | None | False | 255230.514 | 0 |
2927697 | 96520 | None | RGU419 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percent and conforming to IS:15622, of approved brand and manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477, in average 6 mm thickness, including grouting of joints Payment for grouting of joints to be made separately .Size of Tile 600x600 mm FIFTH FLOOR | Sqm | 1461.92 | 1461.92 | 504.26 | False | None | None | False | None | False | 737187.7792 | 0 |
2927698 | 96520 | None | RGU420 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade 0.10 kg of hardener and 0.20 kg of resin per kg , including filling grouting and finishing complete as per direction of Engineerincharge..Size of Tile 600x600 mm FIFTH FLOOR | Sqm | 230.42 | 230.42 | 504.26 | False | None | None | False | None | False | 116191.5892 | 0 |
2927699 | 96520 | None | RGU421 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 1 cement : 3 coarse sand proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete FIFTH FLOOR | Sqm | 3703.3 | 3703.3 | 15.45 | False | None | None | False | None | False | 57215.985 | 0 |
2927700 | 96520 | None | RGU422 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 1 cement: 4 fine sand including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 325.24 | 325.24 | 245.09 | False | None | None | False | None | False | 79713.0716 | 0 |
2927701 | 96520 | None | RGU423 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, selfseal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width and resist hydrostatic pressure upto 16bar for both positive and negative pressure confirming to DIN 1048 part 5 for 56percent reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64percent improvement against control and protecting steel reinforcement against corrosion mixed at 1percent by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix at 0.5 kgbag of cement. For calculation purpose 320 kg of Cement for M20 grade of Concrete is considered in the analysis FIFTH FLOOR | Sqm | 678.04 | 678.04 | 97.28 | False | None | None | False | None | False | 65959.7312 | 0 |
2927702 | 96520 | None | RGU424 | Providing and laying cinder concrete in cement 1:15 1 cement : 15 cinder of 12.5mm nominal gauge on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. FIFTH FLOOR | Cum | 2223.74 | 2223.74 | 50.3 | False | None | None | False | None | False | 111854.122 | 0 |
2927703 | 96520 | None | RGU425 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm thick ness to be specified by the manufacturer , of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 1 Cement : 4 Coarse sand , jointing with grey cement slurry at 3.3 kg m2 including pointing the joints with white cement and matching pigments etc., complete. FIFTH FLOOR | Sqm | 980.12 | 980.12 | 61.59 | False | None | None | False | None | False | 60365.5908 | 0 |
2927704 | 96520 | None | RGU426 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIFTH FLOOR | Sqm | 1597.52 | 1597.52 | 229.64 | False | None | None | False | None | False | 366854.4928 | 0 |
2927705 | 96520 | None | RGU427 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 1 cement : 4 coarse sand , joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 FIFTH FLOOR | Sqm | 4340.54 | 4340.54 | 58.82 | False | None | None | False | None | False | 255310.5628 | 0 |
2927706 | 96520 | None | RGU428 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size as per direction of Engineerin charge and finished smooth. FIFTH FLOOR | Sqm | 3074.87 | 3074.87 | 2.7 | False | None | None | False | None | False | 8302.149 | 0 |
2927707 | 96520 | None | RGU429 | Providing and fixing stainless steel Grade 304 railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature wherever required and fitting the same with necessary stainless steel nuts and bolts complete, ic fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc. including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FIFTH FLOOR | Kgs | 622.91 | 622.91 | 294.15 | False | None | None | False | None | False | 183228.9765 | 0 |
2927708 | 96520 | None | RGU430 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge FIFTH FLOOR | Sqm | 121.28 | 121.28 | 4138.67 | False | None | None | False | None | False | 501937.8976 | 0 |
2927709 | 96520 | None | RGU431 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 171.99 | 171.99 | 753.19 | False | None | None | False | None | False | 129541.1481 | 0 |
2927710 | 96520 | None | RGU432 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 312.01 | 312.01 | 502.13 | False | None | None | False | None | False | 156669.5813 | 0 |
2927711 | 96520 | None | RGU433 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 55.13 | 55.13 | 89.28 | False | None | None | False | None | False | 4922.0064 | 0 |
2927712 | 96520 | None | RGU434 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 126.79 | 126.79 | 89.28 | False | None | None | False | None | False | 11319.8112 | 0 |
2927713 | 96520 | None | RGU435 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. FIFTH FLOOR | Sqm | 58.43 | 58.43 | 109.44 | False | None | None | False | None | False | 6394.5792 | 0 |
2927714 | 96520 | None | RGU436 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. FIFTH FLOOR | Sqm | 746.39 | 746.39 | 109.44 | False | None | None | False | None | False | 81684.9216 | 0 |
2927715 | 96520 | None | RGU437 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. FIFTH FLOOR | Kg | 162.07 | 162.07 | 1298.7 | False | None | None | False | None | False | 210480.309 | 0 |
2927716 | 96520 | None | RGU438 | Providing and supplying aluminium extruded tubular and other alu minium sections as per the architectural drawings and approved draw ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account .The weight of aluminium extruded section shall be taken for purpose of payment. FIFTH FLOOR | Kg | 448.72 | 448.72 | 562.77 | False | None | None | False | None | False | 252526.1544 | 0 |
2927717 | 96520 | None | RGU439 | Providing, assembling and supplying vision glass panels IGUs comprising of hermeticallysealed 612 6 mm insulated glass double glazed vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal structural silicone sealant etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2 For payment, only the actual area of glass on face 1 of the glass panels excluding the areas of the grooves and weather silicone sealant provided and fixed in position, shall be measured in m2. i Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance VLT of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient 0.250.28 and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. FIFTH FLOOR | Sqm | 3354.91 | 3354.91 | 86.58 | False | None | None | False | None | False | 290468.1078 | 0 |
2927718 | 96520 | None | RGU440 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separately :For Fixed Portion : Anodised aluminium anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. FIFTH FLOOR | Kg | 498.33 | 498.33 | 141.75 | False | None | None | False | None | False | 70638.2775 | 0 |
2927719 | 96520 | None | RGU441 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS TERRACE FLOOR | Cum | 13257.94 | 13257.94 | 54.49 | False | None | None | False | None | False | 722425.1506 | 0 |
2927720 | 96520 | None | RGU442 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. OHT WALL TERRACE FLOOR | Cum | 13257.94 | 13257.94 | 16.91 | False | None | None | False | None | False | 224191.7654 | 0 |
2927721 | 96520 | None | RGU443 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC BEAMS TERRACE FLOOR | Cum | 12478.07 | 12478.07 | 28.79 | False | None | None | False | None | False | 359243.6353 | 0 |
2927722 | 96520 | None | RGU444 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. RCC SLAB TERRACE FLOOR | Cum | 11698.19 | 11698.19 | 47.76 | False | None | None | False | None | False | 558705.5544 | 0 |
2927723 | 96520 | None | RGU445 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. LINTELS TERRACE FLOOR | Cum | 12478.07 | 12478.07 | 15.86 | False | None | None | False | None | False | 197902.1902 | 0 |
2927724 | 96520 | None | RGU446 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, The cost includes Formwork all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other. The cost of steel reinforcement, dowel bars and to be paid separately Mix 1:2:4 M15 Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork TERRACE FLOOR | Cum | 10699.83 | 10699.83 | 6.77 | False | None | None | False | None | False | 72437.8491 | 0 |
2927725 | 96520 | None | RGU447 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. TERRACE FLOOR | Tonne | 99565.64 | 99565.64 | 24.12 | False | None | None | False | None | False | 2401523.2368 | 0 |
2927726 | 96520 | None | RGU448 | Extra for providing throating or drip moulding to RCC chejjas with plastering labour charges only as per specifications. Specification No . KBS TERRACE FLOOR | Rmtr | 33.0 | 33.0 | 17.4 | False | None | None | False | None | False | 574.2 | 0 |
2927727 | 96520 | None | RGU449 | Providing and laying autoclaved aerated cement blocks masonry with 150mm200mm230mm300 mm thick AAC blocks as per IS 2185 Part III in super structure above plinth level up to floor I level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. TERRACE FLOOR | Cum | 8879.51 | 8879.51 | 97.64 | False | None | None | False | None | False | 866995.3564 | 0 |
2927728 | 96520 | None | RGU450 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves excluding cost of cement concrete and side clamps , but including cost of materials, labour, usage charges complete as per specifications. TERRACE FLOOR | Cum | 108943.54 | 108943.54 | 0.23 | False | None | None | False | None | False | 25057.0142 | 0 |
2927729 | 96520 | None | RGU451 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. TERRACE FLOOR | Nos | 1120.14 | 1120.14 | 3.0 | False | None | None | False | None | False | 3360.42 | 0 |
2927730 | 96520 | None | RGU452 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm TERRACE FLOOR | Nos | 7166.25 | 7166.25 | 6.0 | False | None | None | False | None | False | 42997.5 | 0 |
2927731 | 96520 | None | RGU453 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm TERRACE FLOOR | Nos | 413.44 | 413.44 | 3.0 | False | None | None | False | None | False | 1240.32 | 0 |
2927732 | 96520 | None | RGU454 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm TERRACE FLOOR | Nos | 165.38 | 165.38 | 6.0 | False | None | None | False | None | False | 992.28 | 0 |
2927733 | 96520 | None | RGU455 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm TERRACE FLOOR | Nos | 77.18 | 77.18 | 12.0 | False | None | None | False | None | False | 926.16 | 0 |
2927734 | 96520 | None | RGU456 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm TERRACE FLOOR | Nos | 110.25 | 110.25 | 3.0 | False | None | None | False | None | False | 330.75 | 0 |
2927735 | 96520 | None | RGU457 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. TERRACE FLOOR | Nos | 1159.83 | 1159.83 | 3.0 | False | None | None | False | None | False | 3479.49 | 0 |
2927736 | 96520 | None | RGU458 | Providing and fixing expansion hold fasteners on C.C. R.C.C.Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm TERRACE FLOOR | Nos | 66.15 | 66.15 | 18.0 | False | None | None | False | None | False | 1190.7 | 0 |
2927737 | 96520 | None | RGU459 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification.do 35 mm thick both side Teak. TERRACE FLOOR | Sqm | 4996.53 | 4996.53 | 9.24 | False | None | None | False | None | False | 46167.9372 | 0 |
2927738 | 96520 | None | RGU460 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC Matching to RAL9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware and Multi point locking system with touch lock. Wall thickness of frame and sash shallbe of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T andP's shall not be made TERRACE FLOOR | Sqm | 7494.94 | 7494.94 | 8.1 | False | None | None | False | None | False | 60709.014 | 0 |
2927739 | 96520 | None | RGU461 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding TERRACE FLOOR | Kg | 186.98 | 186.98 | 170.1 | False | None | None | False | None | False | 31805.298 | 0 |
2927740 | 96520 | None | RGU462 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. TERRACE FLOOR | Sqm | 4984.01 | 4984.01 | 4.2 | False | None | None | False | None | False | 20932.842 | 0 |
2927741 | 96520 | None | RGU463 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm , with necessary accessories and screws etc. complete. TERRACE FLOOR | Nos | 1239.88 | 1239.88 | 3.0 | False | None | None | False | None | False | 3719.64 | 0 |
2927742 | 96520 | None | RGU464 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 1 cement: 3 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. TERRACE FLOOR | Sqm | 359.5 | 359.5 | 258.02 | False | None | None | False | None | False | 92758.19 | 0 |
2927743 | 96520 | None | RGU465 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge... Inside TERRACE FLOOR | Sqm | 347.26 | 347.26 | 230.51 | False | None | None | False | None | False | 80046.9026 | 0 |
2927744 | 96520 | None | RGU466 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. TERRACE FLOOR | Sqm | 111.3 | 111.3 | 488.52 | False | None | None | False | None | False | 54372.276 | 0 |
2927745 | 96520 | None | RGU467 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 1 cement: 4 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. Outside TERRACE FLOOR | Sqm | 388.44 | 388.44 | 840.59 | False | None | None | False | None | False | 326518.7796 | 0 |
2927746 | 96520 | None | RGU468 | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 percent as per ASTM D412, having Tensile strength 1.5 nmm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification. Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant. TERRACE FLOOR | Sqm | 1350.0 | 1350.0 | 1611.74 | False | None | None | False | None | False | 2175849.0 | 0 |
2927747 | 96520 | None | RGU469 | Providing and fixing Ceramic Cool tiles of size 254x254x15mm thickness thermal insulation properties as per GRIHA guidelines with satisfactory SRI 70percent and R value laid on 12mm insulated Mortar mix using heat proof sand complete. TERRACE FLOOR | Sqm | 1275.5 | 1275.5 | 1611.74 | False | None | None | False | None | False | 2055774.37 | 0 |
2927748 | 96520 | None | RGU470 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gm2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. length of mesh only be measured for payment.Plaster mesh 150mm wide TERRACE FLOOR | Rmtr | 42.29 | 42.29 | 574.8 | False | None | None | False | None | False | 24308.292 | 0 |
2927749 | 96520 | None | RGU471 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineerincharge: 10mm to 15 mm wide and 8 mm deep groove. TERRACE FLOOR | Rmtr | 57.88 | 57.88 | 221.4 | False | None | None | False | None | False | 12814.632 | 0 |
2927750 | 96520 | None | RGU472 | Providing and laying Vitrified tiles with thickness 910 mm in different sizes with water absorption less than 0.08 percent and conforming to I.S. 15622, of approved make, in all colours and shade, over 12 mm thick bed of cement mortar 1:3 1 cement: 3 coarse sand , jointing with grey cement slurry at 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete.Size of Tile 600x600 mm TERRACE FLOOR | Sqm | 1307.78 | 1307.78 | 34.92 | False | None | None | False | None | False | 45667.6776 | 0 |
2927751 | 96520 | None | RGU473 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm average thick base of cement mortar 1:4 1 cement : 4 coarse sand laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. TERRACE FLOOR | Sqm | 3174.28 | 3174.28 | 29.21 | False | None | None | False | None | False | 92720.7188 | 0 |
2927752 | 96520 | None | RGU474 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC Volatile Organic Compound content less than 50 gL of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge TERRACE FLOOR | Sqm | 122.43 | 122.43 | 488.52 | False | None | None | False | None | False | 59809.5036 | 0 |
2927753 | 96520 | None | RGU475 | Finishing walls with 100percent Premium acrylic emulsion paint having VOC less than 50 gL and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted with silicon additives, New work Two coats applied at 1.43 L 10 Sqm. Over and including priming coat of exterior primer applied at 0.90 L10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. TERRACE FLOOR | Sqm | 173.63 | 173.63 | 672.47 | False | None | None | False | None | False | 116760.9661 | 0 |
2927754 | 96520 | None | RGU476 | Finishing walls with textured exterior paint of required shade :New work Two coats applied at 3.28 L10 Sqm over and including priming coat of exterior primer applied at 2.20kg10 Sqm to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. TERRACE FLOOR | Sqm | 314.98 | 314.98 | 168.12 | False | None | None | False | None | False | 52954.4376 | 0 |
2927755 | 96520 | None | RGU477 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. TERRACE FLOOR | Sqm | 55.65 | 55.65 | 8.1 | False | None | None | False | None | False | 450.765 | 0 |
2927756 | 96520 | None | RGU478 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. TERRACE FLOOR | Sqm | 128.0 | 128.0 | 8.1 | False | None | None | False | None | False | 1036.8 | 0 |
2927757 | 96520 | None | RGU479 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work hard and soft wood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. TERRACE FLOOR | Sqm | 58.99 | 58.99 | 22.18 | False | None | None | False | None | False | 1308.3982 | 0 |
2927758 | 96520 | None | RGU480 | Polishing in high glossmatt finish melamine clear polish on wood work in required colorwooden shade texture with following process in the sequence as detailed below:1. The surface to be polished is rubbed with sand paper 80120 no. and then with sand paper of 160180 no.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holesgrooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of EngineerinCharge. Final coat to be done in 1 or 2 layers without gap of time. TERRACE FLOOR | Sqm | 753.5 | 753.5 | 22.18 | False | None | None | False | None | False | 16712.63 | 0 |
2927759 | 96520 | None | RGU481 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kgsqcm and class 3 TERRACE FLOOR | Mtr | 457.44 | 457.44 | 477.0 | False | None | None | False | None | False | 218198.88 | 0 |
2927760 | 96520 | None | RGU482 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:: MS angle of 65 x 65 x 10mm TERRACE FLOOR | Mtr | 5343.51 | 5343.51 | 3.3 | False | None | None | False | None | False | 17633.583 | 0 |
2927761 | 96520 | None | RGU483 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. TERRACE FLOOR | Kg | 162.07 | 162.07 | 372.0 | False | None | None | False | None | False | 60290.04 | 0 |
2927762 | 96520 | None | RGU484 | Providing and fixing 6mm Clearopal whitesolar bronzebluegreen tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work. TERRACE FLOOR | Sqm | 3445.31 | 3445.31 | 24.95 | False | None | None | False | None | False | 85960.4845 | 0 |
2927763 | 96520 | None | RGU485 | Providing and Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate SlurryMixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance RH of 100percent, Water Resistance, Non Combustible: as per BS:476 Part4, Fire Performance: as per BS:476 Part6 for Fire Propagation, as per BS:476 Part7 for Surface Spread of Flame, As per UK standards Fire Performace A1S1d0, Thermal Conductivity K= 0.048 to 0.050 wm K as per ECBC code 2007, NRC Noise Reduction Coefficient 0.5 to 0.75 Semi Perforated and Fully Perforated tiles as per IS 8225:1987, Sound Attenuation STA 3032dB,Thickness of tile should be 15mm thick with 450 kgm3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kgm3 density in the center of the body,Light Reflectance 85percent, Weight of material is 55.5 kgm2 and Suitable for Green Building application with InOrganic Recycled content of 46 50percent out of which 18 20percent should be FLYASH and meets the GRIHA and SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11 and12, GRIHA V.3 criterion: 17 and29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal TSections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm and 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kgm2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. GROUND FLOOR | Sqm | 2289.0 | 2289.0 | 888.09 | False | None | None | False | None | False | 2032838.01 | 0 |
2927764 | 96520 | None | RGU486 | Providing and Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate SlurryMixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance RH of 100percent, Water Resistance, Non Combustible: as per BS:476 Part4, Fire Performance: as per BS:476 Part6 for Fire Propagation, as per BS:476 Part7 for Surface Spread of Flame, As per UK standards Fire Performace A1S1d0, Thermal Conductivity K= 0.048 to 0.050 wm K as per ECBC code 2007, NRC Noise Reduction Coefficient 0.5 to 0.75 Semi Perforated and Fully Perforated tiles as per IS 8225:1987, Sound Attenuation STA 3032dB,Thickness of tile should be 15mm thick with 450 kgm3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kgm3 density in the center of the body,Light Reflectance 85percent, Weight of material is 55.5 kgm2 and Suitable for Green Building application with InOrganic Recycled content of 46 50percent out of which 18 20percent should be FLYASH and meets the GRIHA and SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11 and12, GRIHA V.3 criterion: 17 and29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal TSections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm and 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kgm2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. FIRST FLOOR | Sqm | 2311.89 | 2311.89 | 825.78 | False | None | None | False | None | False | 1909112.5242 | 0 |
2927765 | 96520 | None | RGU487 | Providing and Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate SlurryMixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance RH of 100percent, Water Resistance, Non Combustible: as per BS:476 Part4, Fire Performance: as per BS:476 Part6 for Fire Propagation, as per BS:476 Part7 for Surface Spread of Flame, As per UK standards Fire Performace A1S1d0, Thermal Conductivity K= 0.048 to 0.050 wm K as per ECBC code 2007, NRC Noise Reduction Coefficient 0.5 to 0.75 Semi Perforated and Fully Perforated tiles as per IS 8225:1987, Sound Attenuation STA 3032dB,Thickness of tile should be 15mm thick with 450 kgm3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kgm3 density in the center of the body,Light Reflectance 85percent, Weight of material is 55.5 kgm2 and Suitable for Green Building application with InOrganic Recycled content of 46 50percent out of which 18 20percent should be FLYASH and meets the GRIHA and SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11 and12, GRIHA V.3 criterion: 17 and29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal TSections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm and 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kgm2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. SECOND FLOOR | Sqm | 2334.78 | 2334.78 | 875.11 | False | None | None | False | None | False | 2043189.3258 | 0 |
2927766 | 96520 | None | RGU488 | Providing and Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate SlurryMixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance RH of 100percent, Water Resistance, Non Combustible: as per BS:476 Part4, Fire Performance: as per BS:476 Part6 for Fire Propagation, as per BS:476 Part7 for Surface Spread of Flame, As per UK standards Fire Performace A1S1d0, Thermal Conductivity K= 0.048 to 0.050 wm K as per ECBC code 2007, NRC Noise Reduction Coefficient 0.5 to 0.75 Semi Perforated and Fully Perforated tiles as per IS 8225:1987, Sound Attenuation STA 3032dB,Thickness of tile should be 15mm thick with 450 kgm3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kgm3 density in the center of the body,Light Reflectance 85percent, Weight of material is 55.5 kgm2 and Suitable for Green Building application with InOrganic Recycled content of 46 50percent out of which 18 20percent should be FLYASH and meets the GRIHA and SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11 and12, GRIHA V.3 criterion: 17 and29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal TSections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm and 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kgm2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. THIRD FLOOR | Sqm | 2357.67 | 2357.67 | 883.58 | False | None | None | False | None | False | 2083190.0586 | 0 |
2927767 | 96520 | None | RGU489 | Providing and Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate SlurryMixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance RH of 100percent, Water Resistance, Non Combustible: as per BS:476 Part4, Fire Performance: as per BS:476 Part6 for Fire Propagation, as per BS:476 Part7 for Surface Spread of Flame, As per UK standards Fire Performace A1S1d0, Thermal Conductivity K= 0.048 to 0.050 wm K as per ECBC code 2007, NRC Noise Reduction Coefficient 0.5 to 0.75 Semi Perforated and Fully Perforated tiles as per IS 8225:1987, Sound Attenuation STA 3032dB,Thickness of tile should be 15mm thick with 450 kgm3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kgm3 density in the center of the body,Light Reflectance 85percent, Weight of material is 55.5 kgm2 and Suitable for Green Building application with InOrganic Recycled content of 46 50percent out of which 18 20percent should be FLYASH and meets the GRIHA and SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11 and12, GRIHA V.3 criterion: 17 and29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal TSections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm and 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kgm2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. FOURTH FLOOR | Sqm | 2380.56 | 2380.56 | 882.82 | False | None | None | False | None | False | 2101605.9792 | 0 |
2927768 | 96520 | None | RGU490 | Providing and Fixing of Intergral Densified Micro Look edged Eco Friendly Lightweight Calcium Silicate Suspended Ceiling System in Module Size of 600x600x15mm Suitable with Exposed GI Silhouette Profile Black Reveal T 15 Grid for Offices, Hospitals, Institutions, Airports, Banking Sector, Auditoriums, Community halls, laboratories, Factories and All buildings in high humidity or coastal Areas.The Lightweight Calcium Silicate Ceiling tiles shall be made from Non Cementitious Hydrated Calcium Silicate SlurryMixture, Reinforced recycled material with fibers and natural fillers. Free from Formaldehyde and other harmful materials. Doesn't contain any toxic ingrediants. The Tiles should have Humidity Resistance RH of 100percent, Water Resistance, Non Combustible: as per BS:476 Part4, Fire Performance: as per BS:476 Part6 for Fire Propagation, as per BS:476 Part7 for Surface Spread of Flame, As per UK standards Fire Performace A1S1d0, Thermal Conductivity K= 0.048 to 0.050 wm K as per ECBC code 2007, NRC Noise Reduction Coefficient 0.5 to 0.75 Semi Perforated and Fully Perforated tiles as per IS 8225:1987, Sound Attenuation STA 3032dB,Thickness of tile should be 15mm thick with 450 kgm3 density all around on edge resting portion with Integral Densified edge and 10mm thick with 350kgm3 density in the center of the body,Light Reflectance 85percent, Weight of material is 55.5 kgm2 and Suitable for Green Building application with InOrganic Recycled content of 46 50percent out of which 18 20percent should be FLYASH and meets the GRIHA and SVAGRIHA norms under the categories: GRIHA V.2015 criterion:11 and12, GRIHA V.3 criterion: 17 and29 and SVAGRIHA criterion:12. The tiles Shall be laid on 15mm Wide Silhouette Profile Black reveal TSections Flanges colour white having rotary stitching double webbed on all T sections i.e. the Main runner with a web height of 42mm and 1200mm and 600mm Cross Tees with a web height of 42mm having thickness of 0.4mm and Wall angle of 15x20mm with 0.4 mm thickness , having load carrying capacity of 22 to 25 kgm2. The T sections should have Galvanizing of 120 grams per m2 and need to be installed with Suspension system. FIFTH FLOOR | Sqm | 2403.45 | 2403.45 | 884.67 | False | None | None | False | None | False | 2126260.1115 | 0 |
2927769 | 96520 | None | RGU491 | Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 1229.55 | 1229.55 | 380.61 | False | None | None | False | None | False | 467979.0255 | 0 |
2927770 | 96520 | None | RGU492 | Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications FIRST FLOOR | Sqm | 1241.85 | 1241.85 | 353.9 | False | None | None | False | None | False | 439490.715 | 0 |
2927771 | 96520 | None | RGU493 | Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications SECOND FLOOR | Sqm | 1254.14 | 1254.14 | 375.05 | False | None | None | False | None | False | 470365.207 | 0 |
2927772 | 96520 | None | RGU494 | Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications THIRD FLOOR | Sqm | 1266.44 | 1266.44 | 378.68 | False | None | None | False | None | False | 479575.4992 | 0 |
2927773 | 96520 | None | RGU495 | Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications FOURTH FLOOR | Sqm | 1278.73 | 1278.73 | 378.35 | False | None | None | False | None | False | 483807.4955 | 0 |
2927774 | 96520 | None | RGU496 | Providing and fixing in position 12mm thick plaster of paris Gypsum anhydrous for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications FIFTH FLOOR | Sqm | 1291.03 | 1291.03 | 379.24 | False | None | None | False | None | False | 489610.2172 | 0 |
2927775 | 96520 | None | RGU497 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet. Short point upto 3 mts from tapping point to out let via switch box | Point | 282.45 | 282.45 | 126.0 | False | None | None | False | None | False | 35588.7 | 0 |
2927776 | 96520 | None | RGU498 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box | Point | 397.95 | 397.95 | 182.0 | False | None | None | False | None | False | 72426.9 | 0 |
2927777 | 96520 | None | RGU499 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box | Point | 582.75 | 582.75 | 728.0 | False | None | None | False | None | False | 424242.0 | 0 |
2927778 | 96520 | None | RGU500 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches | Point | 710.85 | 710.85 | 328.0 | False | None | None | False | None | False | 233158.8 | 0 |
2927779 | 96520 | None | RGU501 | Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5Sqmm Phase and Neutral and 1x1.0 sqmm Earth wire FRLS multi strand PVC insulated copper wire confirming to IS694: and latest amendments without control switch shall be fixed on the existing plastic sheet gang box, the other end of the wires shall be terminated with sufficient loose length in a woodPVC round block. complete for each outlet. Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches | Point | 1038.45 | 1038.45 | 110.0 | False | None | None | False | None | False | 114229.5 | 0 |
2927780 | 96520 | None | RGU502 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl plugs, MachineNF screws etc., complete. 1 2 Way | Each | 108.15 | 108.15 | 30.0 | False | None | None | False | None | False | 3244.5 | 0 |
2927781 | 96520 | None | RGU503 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl plugs, MachineNF screws etc., complete. 3 Way | Each | 130.2 | 130.2 | 35.0 | False | None | None | False | None | False | 4557.0 | 0 |
2927782 | 96520 | None | RGU504 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl plugs, MachineNF screws etc., complete. 4 5Way | Each | 143.85 | 143.85 | 45.0 | False | None | None | False | None | False | 6473.25 | 0 |
2927783 | 96520 | None | RGU505 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl plugs, MachineNF screws etc., complete. 6 Way | Each | 181.65 | 181.65 | 30.0 | False | None | None | False | None | False | 5449.5 | 0 |
2927784 | 96520 | None | RGU506 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl plugs, MachineNF screws etc., complete. 8 Way | Each | 229.95 | 229.95 | 20.0 | False | None | None | False | None | False | 4599.0 | 0 |
2927785 | 96520 | None | RGU507 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 1 2 Way | Each | 144.9 | 144.9 | 130.0 | False | None | None | False | None | False | 18837.0 | 0 |
2927786 | 96520 | None | RGU508 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 3 Way | Each | 166.95 | 166.95 | 400.0 | False | None | None | False | None | False | 66780.0 | 0 |
2927787 | 96520 | None | RGU509 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 4 5Way | Each | 185.85 | 185.85 | 322.0 | False | None | None | False | None | False | 59843.7 | 0 |
2927788 | 96520 | None | RGU510 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 6 Way | Each | 231.0 | 231.0 | 560.0 | False | None | None | False | None | False | 129360.0 | 0 |
2927789 | 96520 | None | RGU511 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 8 Way | Each | 274.05 | 274.05 | 180.0 | False | None | None | False | None | False | 49329.0 | 0 |
2927790 | 96520 | None | RGU512 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 10 12 Way | Each | 334.95 | 334.95 | 96.0 | False | None | None | False | None | False | 32155.2 | 0 |
2927791 | 96520 | None | RGU513 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 16 Way | Each | 381.15 | 381.15 | 50.0 | False | None | None | False | None | False | 19057.5 | 0 |
2927792 | 96520 | None | RGU514 | Supplying and flush mounting powder coated metal box suitable for mounding modular switch plates. The box should be firmly flush mounted after due groove cutting in brick stone cc wall 18 Way | Each | 425.25 | 425.25 | 10.0 | False | None | None | False | None | False | 4252.5 | 0 |
2927793 | 96520 | None | RGU515 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box. 1 to 2 Module | Each | 143.85 | 143.85 | 160.0 | False | None | None | False | None | False | 23016.0 | 0 |
2927794 | 96520 | None | RGU516 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 3 Module | Each | 169.05 | 169.05 | 435.0 | False | None | None | False | None | False | 73536.75 | 0 |
2927795 | 96520 | None | RGU517 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 4 Module | Each | 183.75 | 183.75 | 367.0 | False | None | None | False | None | False | 67436.25 | 0 |
2927796 | 96520 | None | RGU518 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 6 Module | Each | 245.7 | 245.7 | 590.0 | False | None | None | False | None | False | 144963.0 | 0 |
2927797 | 96520 | None | RGU519 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 8 Module | Each | 298.2 | 298.2 | 200.0 | False | None | None | False | None | False | 59640.0 | 0 |
2927798 | 96520 | None | RGU520 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 1210Module | Each | 361.2 | 361.2 | 96.0 | False | None | None | False | None | False | 34675.2 | 0 |
2927799 | 96520 | None | RGU521 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 16 Module | Each | 416.85 | 416.85 | 50.0 | False | None | None | False | None | False | 20842.5 | 0 |
2927800 | 96520 | None | RGU522 | Supplying and fixing superior quality modular switch mountingpolycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. 1 to 2 ModulemetalPVC box 18 Module | Each | 479.85 | 479.85 | 10.0 | False | None | None | False | None | False | 4798.5 | 0 |
2927801 | 96520 | None | RGU523 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps one way switch | Each | 107.1 | 107.1 | 2652.0 | False | None | None | False | None | False | 284029.2 | 0 |
2927802 | 96520 | None | RGU524 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 amps two way switch | Each | 174.3 | 174.3 | 62.0 | False | None | None | False | None | False | 10806.6 | 0 |
2927803 | 96520 | None | RGU525 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6 Amps 3 way sockets | Each | 179.55 | 179.55 | 896.0 | False | None | None | False | None | False | 160876.8 | 0 |
2927804 | 96520 | None | RGU526 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 stepped fan Regulator's | Each | 374.85 | 374.85 | 520.0 | False | None | None | False | None | False | 194922.0 | 0 |
2927805 | 96520 | None | RGU527 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 616 Amps universal sockets | Each | 247.8 | 247.8 | 535.0 | False | None | None | False | None | False | 132573.0 | 0 |
2927806 | 96520 | None | RGU528 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16A one way switch | Each | 189.0 | 189.0 | 535.0 | False | None | None | False | None | False | 101115.0 | 0 |
2927807 | 96520 | None | RGU529 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 32A DP switch | Each | 342.3 | 342.3 | 52.0 | False | None | None | False | None | False | 17799.6 | 0 |
2927808 | 96520 | None | RGU530 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 6A Bell push | Each | 185.85 | 185.85 | 25.0 | False | None | None | False | None | False | 4646.25 | 0 |
2927809 | 96520 | None | RGU531 | Supplying and fixing one of 230 V Ding dong bell and a flushtype bell push with gang box fixed on necessary wooden or rawlplugs using NF screws with Remote. Ding Donng bell | Each | 258.3 | 258.3 | 25.0 | False | None | None | False | None | False | 6457.5 | 0 |
2927810 | 96520 | None | RGU532 | Supplying and fixing one of 230 V Ding dong bell and a flushtype bell push with gang box fixed on necessary wooden or rawlplugs using NF screws with Remote. Extra length of GI pipe of class B 19mm dia for down rod. | Each | 206.85 | 206.85 | 520.0 | False | None | None | False | None | False | 107562.0 | 0 |
2927811 | 96520 | None | RGU533 | Supplying and fixing one of 230 V Ding dong bell and a flushtype bell push with gang box fixed on necessary wooden or rawlplugs using NF screws with Remote. Supply and fixing metal Fan box with round hook | Each | 122.85 | 122.85 | 520.0 | False | None | None | False | None | False | 63882.0 | 0 |
2927812 | 96520 | None | RGU534 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2mm thick | Mtr | 85.05 | 85.05 | 1500.0 | False | None | None | False | None | False | 127575.0 | 0 |
2927813 | 96520 | None | RGU535 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5mm thick | Mtr | 111.3 | 111.3 | 250.0 | False | None | None | False | None | False | 27825.0 | 0 |
2927814 | 96520 | None | RGU536 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends metal PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 25 mm dia 2mm thick | Mtr | 81.9 | 81.9 | 41296.0 | False | None | None | False | None | False | 3382142.4 | 0 |
2927815 | 96520 | None | RGU537 | Concealed Conduit System Supplying 2 mm thick heavy gauge PVC conduit pipe with suitable size bends metal PVC junction boxes adhesive paste etc..and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wires where ever necessary 32 mm dia 2.5mm thick | Mtr | 108.15 | 108.15 | 4800.0 | False | None | None | False | None | False | 519120.0 | 0 |
2927816 | 96520 | None | RGU538 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 25 mm dia 2mm thick | Mtr | 82.95 | 82.95 | 14000.0 | False | None | None | False | None | False | 1161300.0 | 0 |
2927817 | 96520 | None | RGU539 | Groove Cutting in Wall Supplying 2 mm thick heavy gauge PVC conduit pipe with bends metal junction boxes adhesives paste etc and bracing U or J hooks and cement plastering upto the surface of the trick level and run with 18 SWG Gi fish wire run through out the conduit wherever necessary 32 mm dia 2.5mm thick | Mtr | 103.95 | 103.95 | 1000.0 | False | None | None | False | None | False | 103950.0 | 0 |
2927818 | 96520 | None | RGU540 | Supplying and fixing PVCmetal conduit deep junction box . 25mm deep junction box | Each | 58.8 | 58.8 | 1500.0 | False | None | None | False | None | False | 88200.0 | 0 |
2927819 | 96520 | None | RGU541 | Supplying and fixing PVCmetal conduit deep junction box . 32mm deep junction box | Each | 64.05 | 64.05 | 150.0 | False | None | None | False | None | False | 9607.5 | 0 |
2927820 | 96520 | None | RGU542 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS 694:1990 and cofirming to Latest amendments. 1.5 Sq.mm | Mtr | 27.3 | 27.3 | 6000.0 | False | None | None | False | None | False | 163800.0 | 0 |
2927821 | 96520 | None | RGU543 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS 694:1990 and cofirming to Latest amendments. 2.5 sq.mm | Mtr | 44.1 | 44.1 | 30000.0 | False | None | None | False | None | False | 1323000.0 | 0 |
2927822 | 96520 | None | RGU544 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS 694:1990 and cofirming to Latest amendments. 4 sq.mm | Mtr | 66.15 | 66.15 | 25500.0 | False | None | None | False | None | False | 1686825.0 | 0 |
2927823 | 96520 | None | RGU545 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS 694:1990 and cofirming to Latest amendments. 6sq.mm | Mtr | 96.6 | 96.6 | 6950.0 | False | None | None | False | None | False | 671370.0 | 0 |
2927824 | 96520 | None | RGU546 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS 694:1990 and cofirming to Latest amendments. 10sq.mm | Mtr | 175.35 | 175.35 | 3250.0 | False | None | None | False | None | False | 569887.5 | 0 |
2927825 | 96520 | None | RGU547 | FRLS PVC insulated 1100V grade, multistrand copper with low conductor resistance single core wire in open or concealed wiring system with specified IS 694:1990 and cofirming to Latest amendments. 16sq.mm | Mtr | 333.9 | 333.9 | 750.0 | False | None | None | False | None | False | 250425.0 | 0 |
2927826 | 96520 | None | RGU548 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sq.mm | Each | 3.0 | 3.0 | 6500.0 | False | None | None | False | None | False | 19500.0 | 0 |
2927827 | 96520 | None | RGU549 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5 sq.mm | Each | 4.0 | 4.0 | 5496.0 | False | None | None | False | None | False | 21984.0 | 0 |
2927828 | 96520 | None | RGU550 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4 sq.mm | Each | 7.0 | 7.0 | 2200.0 | False | None | None | False | None | False | 15400.0 | 0 |
2927829 | 96520 | None | RGU551 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sq.mm | Each | 7.0 | 7.0 | 250.0 | False | None | None | False | None | False | 1750.0 | 0 |
2927830 | 96520 | None | RGU552 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10 sqmm | Each | 8.0 | 8.0 | 150.0 | False | None | None | False | None | False | 1200.0 | 0 |
2927831 | 96520 | None | RGU553 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm | Each | 12.0 | 12.0 | 100.0 | False | None | None | False | None | False | 1200.0 | 0 |
2927832 | 96520 | None | RGU554 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 8 Way SP and N | Each | 1946.7 | 1946.7 | 6.0 | False | None | None | False | None | False | 11680.2 | 0 |
2927833 | 96520 | None | RGU555 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way SP and N | Each | 2445.45 | 2445.45 | 1.0 | False | None | None | False | None | False | 2445.45 | 0 |
2927834 | 96520 | None | RGU556 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 16 Way SP and N | Each | 3053.4 | 3053.4 | 4.0 | False | None | None | False | None | False | 12213.6 | 0 |
2927835 | 96520 | None | RGU557 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 4 Way TP and N | Each | 4239.9 | 4239.9 | 18.0 | False | None | None | False | None | False | 76318.2 | 0 |
2927836 | 96520 | None | RGU558 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 6 Way TP and N | Each | 5187.0 | 5187.0 | 4.0 | False | None | None | False | None | False | 20748.0 | 0 |
2927837 | 96520 | None | RGU559 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 8 Way TP and N | Each | 6395.55 | 6395.55 | 2.0 | False | None | None | False | None | False | 12791.1 | 0 |
2927838 | 96520 | None | RGU560 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase 3 phase single DOUBLE door with powder coated painting etc.Made out of 14 SWG MS enclosure. 12 Way TP and N | Each | 9171.75 | 9171.75 | 8.0 | False | None | None | False | None | False | 73374.0 | 0 |
2927839 | 96520 | None | RGU561 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ONOFF, energy cross3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 632 A SP | Each | 435.75 | 435.75 | 410.0 | False | None | None | False | None | False | 178657.5 | 0 |
2927840 | 96520 | None | RGU562 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ONOFF, energy cross3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 632 A DP | Each | 775.95 | 775.95 | 155.0 | False | None | None | False | None | False | 120272.25 | 0 |
2927841 | 96520 | None | RGU563 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ONOFF, energy cross3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 40 A DP | Each | 1113.0 | 1113.0 | 6.0 | False | None | None | False | None | False | 6678.0 | 0 |
2927842 | 96520 | None | RGU564 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ONOFF, energy cross3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 5063 A TPN | Each | 3242.4 | 3242.4 | 25.0 | False | None | None | False | None | False | 81060.0 | 0 |
2927843 | 96520 | None | RGU565 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ONOFF, energy cross3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 40 A TPN | Each | 3196.2 | 3196.2 | 18.0 | False | None | None | False | None | False | 57531.6 | 0 |
2927844 | 96520 | None | RGU566 | Supplying and fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ONOFF, energy cross3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 632 A TPN | Each | 1802.85 | 1802.85 | 8.0 | False | None | None | False | None | False | 14422.8 | 0 |
2927845 | 96520 | None | RGU567 | Supplying, fixing and wiring Residual current circuit breaker RCCB 240450V up to 300mA sensitivity on existing wood panel board. 3240Amps 2 pole | Each | 4786.95 | 4786.95 | 15.0 | False | None | None | False | None | False | 71804.25 | 0 |
2927846 | 96520 | None | RGU568 | Supplying, fixing and wiring Residual current circuit breaker RCCB 240450V up to 300mA sensitivity on existing wood panel board. 63Amps 4 pole | Each | 5822.25 | 5822.25 | 5.0 | False | None | None | False | None | False | 29111.25 | 0 |
2927847 | 96520 | None | RGU569 | Supply, Installation, testing and Commissioning of 63A, three phase 5pin Plug and socket outlet controlled by 63A 4pole MCB 10 KA For AC C Curve and Lab. | Each | 8650.0 | 8650.0 | 8.0 | False | None | None | False | None | False | 69200.0 | 0 |
2927848 | 96520 | None | RGU570 | Supply, Installation, testing and Commissioning of 32A, three phase 5pin Plug and socket outlet controlled by 32A 4pole MCB 10 KA For AC C Curve and Lab. | Each | 3750.0 | 3750.0 | 15.0 | False | None | None | False | None | False | 56250.0 | 0 |
2927849 | 96520 | None | RGU571 | Supply, Installation, testing and Commissioning of 20A, single phase 3pin plug and socket outlet controlled by 20A 2POLE MCB 10 KA For AC C Curve and Lab. | Each | 2450.0 | 2450.0 | 60.0 | False | None | None | False | None | False | 147000.0 | 0 |
2927850 | 96520 | None | RGU572 | Supply, Installation, testing and Commissioning of 32A, single phase 3pin plug and socket outlet controlled by 32A 2POLE MCB 10 KA For AC C Curve and Lab. | Each | 3800.0 | 3800.0 | 48.0 | False | None | None | False | None | False | 182400.0 | 0 |
2927851 | 96520 | None | RGU573 | SP andN Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB . The entire plug and socket shall be mounted in a thermoplastic powder coated metal box and wired Completely. 10A | Each | 5822.25 | 5822.25 | 10.0 | False | None | None | False | None | False | 58222.5 | 0 |
2927852 | 96520 | None | RGU574 | SP andN Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB . The entire plug and socket shall be mounted in a thermoplastic powder coated metal box and wired Completely. 20A | Each | 5822.25 | 5822.25 | 5.0 | False | None | None | False | None | False | 29111.25 | 0 |
2927853 | 96520 | None | RGU575 | TP andN Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB . The entire plug and socket shall be mounted in a thermoplastic powder coated metal box and wired Completely. 20A | Each | 5822.25 | 5822.25 | 4.0 | False | None | None | False | None | False | 23289.0 | 0 |
2927854 | 96520 | None | RGU576 | TP andN Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB Without MCB . The entire plug and socket shall be mounted in a thermoplastic powder coated metal box and wired Completely 30A | Each | 5822.25 | 5822.25 | 2.0 | False | None | None | False | None | False | 11644.5 | 0 |
2927855 | 96520 | None | RGU577 | Supply and Installation Fixing Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 Weather Proof , rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase Three Phase Energy Meter in suitable base plate and having a provision for Fuse MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 300 mm x 214 mm | Each | 4737.6 | 4737.6 | 25.0 | False | None | None | False | None | False | 118440.0 | 0 |
2927856 | 96520 | None | RGU578 | Supply and Installation Fixing Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 Weather Proof , rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase Three Phase Energy Meter in suitable base plate and having a provision for Fuse MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 450 mm x 214 mm | Each | 6471.15 | 6471.15 | 15.0 | False | None | None | False | None | False | 97067.25 | 0 |
2927857 | 96520 | None | RGU579 | Supply and installation of 300 mm wide and 40mm height, 1.6 mm thick ladder type cable trays fixed with MS supports,anchor bolt etc.,complete as required at site. | Mtr | 465.0 | 465.0 | 100.0 | False | None | None | False | None | False | 46500.0 | 0 |
2927858 | 96520 | None | RGU580 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI boltsnuts and washer or welding as required. 150 X 50 mm | Mtr | 486.15 | 486.15 | 200.0 | False | None | None | False | None | False | 97230.0 | 0 |
2927859 | 96520 | None | RGU581 | 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI boltsnuts and washer or welding as required. 300 x 50 mm | Mtr | 616.35 | 616.35 | 350.0 | False | None | None | False | None | False | 215722.5 | 0 |
2927860 | 96520 | None | RGU582 | Supply and laying of Raceways 200mm wide x 40mm Deep MS cold galvanised 16 guage made of CRCA sheet with removable type cover plate maximum length of each section shall not be more than 2.5 Mtrs. Length. etc., as required. | Mtr | 865.0 | 865.0 | 120.0 | False | None | None | False | None | False | 103800.0 | 0 |
2927861 | 96520 | None | RGU583 | Supply and laying of Raceways 100mm wide x 40mm Deep MS cold galvanised 16 guage made of CRCA sheet with removable type cover plate maximum length of each section shall not be more than 2.5 Mtrs. Length. etc., as required. | Mtr | 610.0 | 610.0 | 120.0 | False | None | None | False | None | False | 73200.0 | 0 |
2927862 | 96520 | None | RGU584 | Supply and laying of underfloor concealed raceways manufactured from 1.5 mm thick cover and base including partitions for multicompartment raceways , zero spangle pregalvanized sheet steel with 275 GSM 36.67 microns coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 50 x 38 x 2500mm, 1 compartment | Mtr | 662.55 | 662.55 | 50.0 | False | None | None | False | None | False | 33127.5 | 0 |
2927863 | 96520 | None | RGU585 | Supply and laying of underfloor concealed raceways manufactured from 1.5 mm thick cover and base including partitions for multicompartment raceways , zero spangle pregalvanized sheet steel with 275 GSM 36.67 microns coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 75 x 38 x 2500mm, 1 compartment | Mtr | 777.0 | 777.0 | 35.0 | False | None | None | False | None | False | 27195.0 | 0 |
2927864 | 96520 | None | RGU586 | Supply and laying of underfloor concealed raceways manufactured from 1.5 mm thick cover and base including partitions for multicompartment raceways , zero spangle pregalvanized sheet steel with 275 GSM 36.67 microns coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 100 x 38 x 2500mm, 2 compartments | Mtr | 1119.3 | 1119.3 | 25.0 | False | None | None | False | None | False | 27982.5 | 0 |
2927865 | 96520 | None | RGU587 | Supplying,Installation,testing and commissioning of passive infrared PIR technology based accupancy sensor with day light dimming Lighting levell shall be regulated as per availability of natural day light in an area along with accuoancy detection . Having high preformance,regulating programmable type,suitable for connected load upto 10 Amp,for mounting height upto 2.8 mtr. and for 5 m diameter coverage area along with necessary fixing arrangements ic programming at site etc, complete as required. DSR 2022 | Each | 9629.55 | 9629.55 | 28.0 | False | None | None | False | None | False | 269627.4 | 0 |
2927866 | 96520 | None | RGU588 | Supplying,Installation,testing and commissioning of microwave technology based accupancy sensor having high preformance,non regulating programmable type,suitable for connected load upto 10 Amp,for mounting height upto 2.6 mtr. and for 5 m X 20m coverage area along with necessary fixing arrangements ic programming at site etc, complete as required. DSR 2022 | Each | 12487.65 | 12487.65 | 30.0 | False | None | None | False | None | False | 374629.5 | 0 |
2927867 | 96520 | None | RGU589 | Supplying of .....feet PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours and 70percent lumen maintenance with CRI 80. PowerInput: 220240Vat 5060Hz and Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition. LED light fitting 1 x 2ft 910 W | Each | 578.55 | 578.55 | 40.0 | False | None | None | False | None | False | 23142.0 | 0 |
2927868 | 96520 | None | RGU590 | Supplying of .....feet PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours and 70percent lumen maintenance with CRI 80. PowerInput: 220240Vat 5060Hz and Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition. LED light fitting 1 x 4ft 2022 W | Each | 724.5 | 724.5 | 720.0 | False | None | None | False | None | False | 521640.0 | 0 |
2927869 | 96520 | None | RGU591 | Supplying of .....feet PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burninghours and 70percent lumen maintenance with CRI 80. PowerInput: 220240Vat 5060Hz and Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition. LED light fitting 1 x 4ft 3640 W | Each | 1332.45 | 1332.45 | 20.0 | False | None | None | False | None | False | 26649.0 | 0 |
2927870 | 96520 | None | RGU592 | Supply of roundsquare recesssurface mounted rollingtype LED Down light with ...... W GU 10 LED Lamp RibFabricated from diecast aluminium with white powdercoated prewired to mains connector and has swivelling unit ofaluminium die cast eye ball and LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours and 70percentlumen maintenance with CRI 80. Power Input: 220240Vat5060Hz and Power factor 0.9 along with CE approved. 2yearsWarranty against any manufacturing defect working understandard electrical condition LED square or round down light 1012W | Each | 929.25 | 929.25 | 120.0 | False | None | None | False | None | False | 111510.0 | 0 |
2927871 | 96520 | None | RGU593 | Supply of roundsquare recesssurface mounted rollingtype LED Down light with ...... W GU 10 LED Lamp RibFabricated from diecast aluminium with white powdercoated prewired to mains connector and has swivelling unit ofaluminium die cast eye ball and LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours and 70percentlumen maintenance with CRI 80. Power Input: 220240Vat5060Hz and Power factor 0.9 along with CE approved. 2yearsWarranty against any manufacturing defect working understandard electrical condition LED square or round down light 1518W | Each | 1390.2 | 1390.2 | 280.0 | False | None | None | False | None | False | 389256.0 | 0 |
2927872 | 96520 | None | RGU594 | Supplying of recess mounting non integral type ........ LED wluminaire comprising of pressure decastextruded aluminiumhousing, with spring loaded false ceiling clA, Power LEDs withCCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W,120degree beam spread, life 25000 burning hours andCompliance to IS 10322IEC 60598, LM 79 and LM 80. Thelamp compartment is enclosed with anti glare opal diffuserwhich enhances the lighting level LEDs are driven by HFelectronic driver integrated in a separate control gearassembly., with PF 0.95, power loss should 5percent of lampWage., short circuit and open circuit protection to be integratedin the circuit, THD less than 20percent, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BISApproved and Tested by NABLCPRI accredited laboratorywith 2 years Warranty against any manufacturing defectworking under standard electrical condition. LED modular down light 2ftx2ft36W | Each | 4780.65 | 4780.65 | 68.0 | False | None | None | False | None | False | 325084.2 | 0 |
2927873 | 96520 | None | RGU595 | Supply and fixing of 12W LED retro fit lamp with holder | Each | 650.0 | 650.0 | 52.0 | False | None | None | False | None | False | 33800.0 | 0 |
2927874 | 96520 | None | RGU596 | Supply and fixing of 18W LED Bulk Head light Fixture | Each | 1850.0 | 1850.0 | 45.0 | False | None | None | False | None | False | 83250.0 | 0 |
2927875 | 96520 | None | RGU597 | Supply,installation and Testing of LED Clean room Fixtures 2'x2'3436W | Each | 5200.0 | 5200.0 | 54.0 | False | None | None | False | None | False | 280800.0 | 0 |
2927876 | 96520 | None | RGU598 | Supply,installation and Testing of LED Clean room Fixtures 1'x1'2026W | Each | 3600.0 | 3600.0 | 36.0 | False | None | None | False | None | False | 129600.0 | 0 |
2927877 | 96520 | None | RGU599 | Supplying exhaust fan of 1440 RPM of 300 mm 12inches size withbracket blades complete for light duty suitable to operate on230V 50Hz, AC Supply. | Each | 1566.6 | 1566.6 | 50.0 | False | None | None | False | None | False | 78330.0 | 0 |
2927878 | 96520 | None | RGU600 | Supplying of Ceiling Fan with Capacitor rating As perguideline of BEE 5 star rating and IS:37479 and alsocomply with IS: 17091984 with latest amendment, Ratedvoltage 220 V50 Hz, Rated power input 48 W + 10 percent,Rated current As per IS:37479, Rated power factor 0.9lagging min , Rated speed 350 + 10percent RPM, Rated airdelivery 210 + 10percent Cubic Meter Minimum, Rated servicevalue 4.2 CMM W, Three Blades of blade leaf 1.05 mm thickAluminium Alloy sheet, Class B motor insulation, Bearing Twoball bearings, Top 6202, Bottom 6201, as per IS specification,Motor winding. Temp rise Shall not exceed 75 deg C over andambient of 40 0C by resistance method at 245 V, Insulationresistance Shall not be less than Two Mega Ohms 2M Ohms ,Leakage current Should not exceed 210 Micro Amp, Powerinput, W and current, Air Delivery and Fan Speed as perIS:3741979 with latest amendment, 2 year manufacturerWarranty. 48inches Sweep 5 Star 1200 mm | Each | 2810.85 | 2810.85 | 500.0 | False | None | None | False | None | False | 1405425.0 | 0 |
2927879 | 96520 | None | RGU601 | Supplying of Ceiling Fan with Capacitor rating As perguideline of BEE 5 star rating and IS:37479 and alsocomply with IS: 17091984 with latest amendment, Ratedvoltage 220 V50 Hz, Rated power input 48 W + 10 percent,Rated current As per IS:37479, Rated power factor 0.9lagging min , Rated speed 350 + 10percent RPM, Rated airdelivery 210 + 10percent Cubic Meter Minimum, Rated servicevalue 4.2 CMM W, Three Blades of blade leaf 1.05 mm thickAluminium Alloy sheet, Class B motor insulation, Bearing Twoball bearings, Top 6202, Bottom 6201, as per IS specification,Motor winding. Temp rise Shall not exceed 75 deg C over andambient of 40 0C by resistance method at 245 V, Insulationresistance Shall not be less than Two Mega Ohms 2M Ohms ,Leakage current Should not exceed 210 Micro Amp, Powerinput, W and current, Air Delivery and Fan Speed as perIS:3741979 with latest amendment, 2 year manufacturerWarranty. 56inches Sweep 5 Star 1400 mm | Each | 3941.7 | 3941.7 | 20.0 | False | None | None | False | None | False | 78834.0 | 0 |
2927880 | 96520 | None | RGU602 | Supplying wall mounting fan suitable to operate at singlephase230v AC. supply. 400 mm Sweep | Each | 3372.6 | 3372.6 | 12.0 | False | None | None | False | None | False | 40471.2 | 0 |
2927881 | 96520 | None | RGU603 | Fixing all types and all capacities of fluorescent false ceiling spot light CFL LED fittings indoor on the wall ceiling rafters girders using 230.0076inches twin twisted PVC insulatedwires, required Nos of round blocks and clA. | Each | 128.1 | 128.1 | 1248.0 | False | None | None | False | None | False | 159868.8 | 0 |
2927882 | 96520 | None | RGU604 | Fixing a ceiling Wall mounting fan of all capacities and alltypes to the existing 'S'' hook with fan regulator to the existingboard together with supplying and fixing 5 A. ceiling rose,necessary length of 23 0.0076 inch PVC insulated twintwisted copper wire and wiring. | Each | 179.55 | 179.55 | 532.0 | False | None | None | False | None | False | 95520.6 | 0 |
2927883 | 96520 | None | RGU605 | Fixing one exhaust fan in the nitch already left in the wall withbolts and nuts and 5 A. ceiling rose with sufficient length of 230.0076 inch PVC insulated twin core wire. | Each | 516.6 | 516.6 | 50.0 | False | None | None | False | None | False | 25830.0 | 0 |
2927884 | 96520 | None | RGU606 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateclear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 5060Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 100W System Power consumption. LED Efficiency 1301mw, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and CreeNichia LumiledsOsram make LED Source LED Floodlight 70W | Each | 7106.4 | 7106.4 | 12.0 | False | None | None | False | None | False | 85276.8 | 0 |
2927885 | 96520 | None | RGU607 | Fabricating, supplying and erection of ... ms long hotdip Galvanized Conical hot dip Pole with BSEN 10025 gradeS355JO steel plate for shaft, IS 2062 for base plate with dooropening arrangements, including suitable boards, Bakelitesheet and MCBs as per IS specifications suitable to withstandthe wind speed of 47 ms for ....... m Pole in single section andsingle joint welded as per IS 9595IS10178AWS havingdimensions bottom ..... mm , top ... mm with 3 mm thick,suitable base plate and 4Nos of.........long J bolts along withtemplate and the Pole shall be hot dip galvanized in singledipping with not less than 65micron as per ASTMA123 and 153etc., excluding foundation as per drawing appended. 7 Meters Top 75mm and botton 145mm dia | Each | 15750.0 | 15750.0 | 12.0 | False | None | None | False | None | False | 189000.0 | 0 |
2927886 | 96520 | None | RGU608 | Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1000mm Standard 4050MM dia | Each | 1785.0 | 1785.0 | 12.0 | False | None | None | False | None | False | 21420.0 | 0 |
2927887 | 96520 | None | RGU609 | LED STREET LIGHT Supply of LED street light with pressure die cast aluminium housing body with optimal heat sink for better thermal dissipation, Diffuser with injection moulded and is made of polycorbonate material with high transmission index, delivering superior light output . Rated life Burning Hrs. 50000 hr at Lumen maintanance of 70percent. CCT 5500 K, IP 66 optical and electrical compartment and impact resistance of complete luminare IK08. Power Factor 0.9 with mains current should not be greater than 0.1A to 0.7 A and Surge Protection Min 4 KV alongwith over voltage overload, short circuit miss wiring protection. Compatable for pole mounting with outer dia of 40 mm to 50mm .Universal voltage driver to operates wide voltage from 100 V to 270 Volts , 50 60 Hz application. Over load and short circuit protection ensures reliable operation in spite of problem in output side. Complaince to IS 10322IEC 60598, LM 79 and LM 80 Adherance with ROHS .UL approved MCPCB . Supplying, and fixing of hot dip Galvanized M.S.Bracket suitable for out door liminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Top access street light with single screws to ensure ease of maintenance at the sight site location with minimized tools. LED Light fixture with.... W System Power consumption. LED Efficiency 130 mw at Fixture Efficiency 80 mw with nominal CRI 75 Luminarie manufacture should have inhouse facility accredited by NABL CPRI and any government certified agency and Design with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 years against any manufacturing defects working under standard electrical conditions suitable for B1 B2 Roads as per IS 1944 Part and Part II LED Streetlight 70watts | Each | 6291.6 | 6291.6 | 12.0 | False | None | None | False | None | False | 75499.2 | 0 |
2927888 | 96520 | None | RGU610 | Fixing halogenmetal halide SVLILLED floodlight fitting overexisting pole wall ceiling including clA, bolts, nuts and wiringusing suitable capacity wires. | Each | 170.1 | 170.1 | 12.0 | False | None | None | False | None | False | 2041.2 | 0 |
2927889 | 96520 | None | RGU611 | Supply and laying double walled corrugated DWC HDPE pipe inculding all necessary connecting sockets couplings Tees bends Endcaps of same materials in existing trench as per is 14930 part11 suitable for drawing underground cable 63mm OD 50MM ID | Mtr | 255.0 | 255.0 | 260.0 | False | None | None | False | None | False | 66300.0 | 0 |
2927890 | 96520 | None | RGU612 | Digging of trench of 0.6m deep x 0.50 mtr wide refiling the trench to the required ground level and consolidating etc., complete. As per Civil SR KSRB I2, P7 706 SR 20192020 | Mtr | 79.8 | 79.8 | 550.0 | False | None | None | False | None | False | 43890.0 | 0 |
2927891 | 96520 | None | RGU613 | Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm allround the cable. SR 20192020 | Mtr | 105.0 | 105.0 | 450.0 | False | None | None | False | None | False | 47250.0 | 0 |
2927892 | 96520 | None | RGU614 | Supply of LED pole mounting type post top lantern withpressure die cast aluminium housing body for optimalthermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonateclear glass material, delivering superior light outputRated lifeBurning Hrs 50000 hrat Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impactresistance of complete luminaire IK08. Power Factor 0.9 withmains, Surge Protection Min 5KV along with OvervoltageOverload, short circuit misswiring protection.Compatible for pole mounting with outer dia of 40mm to50mm. Universal Voltage driver to operate wide voltagerange from 100V to 270V 5060Hz application. Compliance toIS 103221 EC 60598, LM 79 and LM 80 Adherence withRoHS. UL approved MCPCB LED Efficiency 1301mw, nominalCRI 75. Luminaire manufacturer should have in house facilityaccredited by NABLCPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008.Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2Years against any manufacturing defect working understandard electrical conditions as mentioned above should begiven by LED manufacturer and CreeNichia LumiledsOsrammake LED Source. LED Post Top Lantern with 2530 Watts | Each | 8108.1 | 8108.1 | 10.0 | False | None | None | False | None | False | 81081.0 | 0 |
2927893 | 96520 | None | RGU615 | Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonateclear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltageOverload, short circuit misswiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 5060Hz application. Compliance to IS 10322IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition 8w 1 Mtr Height | Each | 4755.4 | 4755.4 | 10.0 | False | None | None | False | None | False | 47554.0 | 0 |
2927894 | 96520 | None | RGU616 | Fabricating supplying and mounting MS box made out....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.53 | 0.53 | 710000.0 | False | None | None | False | None | False | 376300.0 | 0 |
2927895 | 96520 | None | RGU617 | Fabricating supplying and mounting MS box made out....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG | Sq CM | 0.45 | 0.45 | 2341820.0 | False | None | None | False | None | False | 1053819.0 | 0 |
2927896 | 96520 | None | RGU618 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolicFRPDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4x50x10 mm Aluminium Strips | Mtr | 4667.25 | 4667.25 | 60.0 | False | None | None | False | None | False | 280035.0 | 0 |
2927897 | 96520 | None | RGU619 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolicFRPDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips | Mtr | 3606.75 | 3606.75 | 14.0 | False | None | None | False | None | False | 50494.5 | 0 |
2927898 | 96520 | None | RGU620 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolicFRPDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Strips | Mtr | 2588.25 | 2588.25 | 15.5 | False | None | None | False | None | False | 40117.875 | 0 |
2927899 | 96520 | None | RGU621 | Supplying and fixing angle iron frame work fabricated out ofM.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | Mtr | 582.75 | 582.75 | 51.0 | False | None | None | False | None | False | 29720.25 | 0 |
2927900 | 96520 | None | RGU622 | Supplying and fixing angle iron frame work fabricated out ofM.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | Mtr | 320.25 | 320.25 | 61.0 | False | None | None | False | None | False | 19535.25 | 0 |
2927901 | 96520 | None | RGU623 | Supplying and fixing of One no. incomer of 1 x 1250A 4P EDO ACB with microprocessor based over current, short circuit and earth fault release. ACB releases shall have over current different time settings, short ckt. release with variable setting, short time delay, instantaneous current setting, earth fault release, earth fault time delay. Suitable links shall be provided for 1250A after derating . 1250 A ACB 50KA Incomer and Bus Coupler | Each | 195750.0 | 195750.0 | 2.0 | False | None | None | False | None | False | 391500.0 | 0 |
2927902 | 96520 | None | RGU624 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400500 A 36KA DG Incomer | Each | 43571.85 | 43571.85 | 3.0 | False | None | None | False | None | False | 130715.55 | 0 |
2927903 | 96520 | None | RGU625 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 500630 A 50KA | Each | 43993.95 | 43993.95 | 5.0 | False | None | None | False | None | False | 219969.75 | 0 |
2927904 | 96520 | None | RGU626 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA | Each | 14119.35 | 14119.35 | 17.0 | False | None | None | False | None | False | 240028.95 | 0 |
2927905 | 96520 | None | RGU627 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA | Each | 8911.35 | 8911.35 | 7.0 | False | None | None | False | None | False | 62379.45 | 0 |
2927906 | 96520 | None | RGU628 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 125 A 25 kA | Each | 10858.05 | 10858.05 | 1.0 | False | None | None | False | None | False | 10858.05 | 0 |
2927907 | 96520 | None | RGU629 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 632 A SP | Each | 435.75 | 435.75 | 23.0 | False | None | None | False | None | False | 10022.25 | 0 |
2927908 | 96520 | None | RGU630 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6 32 A DP | Each | 775.95 | 775.95 | 12.0 | False | None | None | False | None | False | 9311.4 | 0 |
2927909 | 96520 | None | RGU631 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5063 A TPN For TVSS Connectivity | Each | 3242.4 | 3242.4 | 55.0 | False | None | None | False | None | False | 178332.0 | 0 |
2927910 | 96520 | None | RGU632 | Surge Protection device SPD 3 phase TypeB | Each | 13500.0 | 13500.0 | 1.0 | False | None | None | False | None | False | 13500.0 | 0 |
2927911 | 96520 | None | RGU633 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN | Each | 3196.2 | 3196.2 | 35.0 | False | None | None | False | None | False | 111867.0 | 0 |
2927912 | 96520 | None | RGU634 | Supplying, fixing and wiring Earth Leakage Miniature CircuitBreaker ELMCB 240450V upto 300mA sensitivity on existing woodpanel board. 3240 A 4 pole | Each | 5404.35 | 5404.35 | 2.0 | False | None | None | False | None | False | 10808.7 | 0 |
2927913 | 96520 | None | RGU635 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230440VAC. 50 Hz1224V D.C. | Each | 540.75 | 540.75 | 60.0 | False | None | None | False | None | False | 32445.0 | 0 |
2927914 | 96520 | None | RGU636 | Supplying, fixing and wiring 0 to 600V 96x96mm ACVoltmeter on existing panelwood board. | Each | 474.6 | 474.6 | 19.0 | False | None | None | False | None | False | 9017.4 | 0 |
2927915 | 96520 | None | RGU637 | Supplying, fixing and wiring earth leakage relay with corebalanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delayauto manual reset facility suitable to mount on DIN rail flush mounting on panel board. | Each | 9717.75 | 9717.75 | 54.0 | False | None | None | False | None | False | 524758.5 | 0 |
2927916 | 96520 | None | RGU638 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9780.75 | 9780.75 | 2.0 | False | None | None | False | None | False | 19561.5 | 0 |
2927917 | 96520 | None | RGU639 | Supplying, fixing and wiring rotary selector switch suitablefor Ammeter | Each | 210.0 | 210.0 | 15.0 | False | None | None | False | None | False | 3150.0 | 0 |
2927918 | 96520 | None | RGU640 | Supplying, fixing and wiring rotary selector switch suitablefor Voltmeter | Each | 168.0 | 168.0 | 19.0 | False | None | None | False | None | False | 3192.0 | 0 |
2927919 | 96520 | None | RGU641 | Supplying, fixing and wiring 10005A to 16005A 15VA Burden class 1 Current Transformer | Each | 840.0 | 840.0 | 4.0 | False | None | None | False | None | False | 3360.0 | 0 |
2927920 | 96520 | None | RGU642 | Supplying, fixing and wiring 0 to 1500A CT operated AC analogtype Ammeter without CT | Each | 504.0 | 504.0 | 51.0 | False | None | None | False | None | False | 25704.0 | 0 |
2927921 | 96520 | None | RGU643 | Supplying, fixing and wiring 3 Phase Digital Ammeter Voltmeter | Each | 1496.25 | 1496.25 | 8.0 | False | None | None | False | None | False | 11970.0 | 0 |
2927922 | 96520 | None | RGU644 | Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect disconnect banks, with automatic recognition or with standard programs. | Each | 22722.0 | 22722.0 | 1.0 | False | None | None | False | None | False | 22722.0 | 0 |
2927923 | 96520 | None | RGU645 | Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on PhenolicFRPDMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete. Supplying .. A rated 3Phase with Neutral bus bar arrangement using required capacity Electrolytic Al strips covered with Heat shrinkable PVC sleves mounted on PhenolicFRPDMC insulators which are mounted on powder coated 40x6mm MS flat frame work in existing Panel Board. The Bus bars shall have suitable holes for termination of Incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc complete. 600 A 4 x 75 x 10 mm Aluminium Strips | Mtr | 5906.25 | 5906.25 | 36.0 | False | None | None | False | None | False | 212625.0 | 0 |
2927924 | 96520 | None | RGU646 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 36 KA | Each | 25857.3 | 25857.3 | 1.0 | False | None | None | False | None | False | 25857.3 | 0 |
2927925 | 96520 | None | RGU647 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu=100percent lcs . In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open . Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kA | Each | 6390.3 | 6390.3 | 4.0 | False | None | None | False | None | False | 25561.2 | 0 |
2927926 | 96520 | None | RGU648 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 16 32 A TP | Each | 842.1 | 842.1 | 2.0 | False | None | None | False | None | False | 1684.2 | 0 |
2927927 | 96520 | None | RGU649 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 63 A TP | Each | 1254.75 | 1254.75 | 4.0 | False | None | None | False | None | False | 5019.0 | 0 |
2927928 | 96520 | None | RGU650 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400440 V grade, for power factor improvement of rotating machineries like induction motor. | Kvar | 504.0 | 504.0 | 300.0 | False | None | None | False | None | False | 151200.0 | 0 |
2927929 | 96520 | None | RGU651 | Fixing a shunt capacitor of ... kVAR capacity with necessary clA, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. 6 to 10 kVAR | Each | 224.7 | 224.7 | 2.0 | False | None | None | False | None | False | 449.4 | 0 |
2927930 | 96520 | None | RGU652 | ILPB Type push button with Lanmp ONOFF L andT Make | Each | 350.0 | 350.0 | 20.0 | False | None | None | False | None | False | 7000.0 | 0 |
2927931 | 96520 | None | RGU653 | Supply and fixing of 4pole power contactor with NONC contacts on existing woodpanel board using necessary bolts, nuts, washers and wiring etc., complete with AC3 Rating and as per IS13947. 25 A | Each | 1354.5 | 1354.5 | 1.0 | False | None | None | False | None | False | 1354.5 | 0 |
2927932 | 96520 | None | RGU654 | Supply and fixing of 3pole Capacitor switching contactor with NONC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing woodpanel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 12.5 KVAR | Each | 3046.05 | 3046.05 | 2.0 | False | None | None | False | None | False | 6092.1 | 0 |
2927933 | 96520 | None | RGU655 | Supply and fixing of 3pole Capacitor switching contactor with NONC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing woodpanel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 30 KVAR | Each | 5527.2 | 5527.2 | 4.0 | False | None | None | False | None | False | 22108.8 | 0 |
2927934 | 96520 | None | RGU656 | Supply and fixing of 3pole Capacitor switching contactor with NONC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest inrush current , fixed on existing woodpanel board using necessary bolts, nuts, washers and wiring etc., complete with AC 690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 50 KVAR | Each | 15820.35 | 15820.35 | 4.0 | False | None | None | False | None | False | 63281.4 | 0 |
2927935 | 96520 | None | RGU657 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V PLUG 16A | Each | 407.15 | 407.15 | 2.0 | False | None | None | False | None | False | 814.3 | 0 |
2927936 | 96520 | None | RGU658 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V PLUG 32A | Each | 575.48 | 575.48 | 6.0 | False | None | None | False | None | False | 3452.88 | 0 |
2927937 | 96520 | None | RGU659 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V PLUG 16A | Each | 474.74 | 474.74 | 5.0 | False | None | None | False | None | False | 2373.7 | 0 |
2927938 | 96520 | None | RGU660 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V PLUG 32A | Each | 640.35 | 640.35 | 5.0 | False | None | None | False | None | False | 3201.75 | 0 |
2927939 | 96520 | None | RGU661 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V SOCKET 16A | Each | 556.57 | 556.57 | 2.0 | False | None | None | False | None | False | 1113.14 | 0 |
2927940 | 96520 | None | RGU662 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V SOCKET 32A | Each | 700.39 | 700.39 | 6.0 | False | None | None | False | None | False | 4202.34 | 0 |
2927941 | 96520 | None | RGU663 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V SOCKET 16A | Each | 665.47 | 665.47 | 5.0 | False | None | None | False | None | False | 3327.35 | 0 |
2927942 | 96520 | None | RGU664 | MS Enclosures Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V SOCKET 32A | Each | 869.21 | 869.21 | 6.0 | False | None | None | False | None | False | 5215.26 | 0 |
2927943 | 96520 | None | RGU665 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 10 Sqmm, 4 Core. | Km | 123904.2 | 123904.2 | 0.5 | False | None | None | False | None | False | 61952.1 | 0 |
2927944 | 96520 | None | RGU666 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 16 Sqmm, 4 Core. | Km | 148934.1 | 148934.1 | 1.0 | False | None | None | False | None | False | 148934.1 | 0 |
2927945 | 96520 | None | RGU667 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 25 Sqmm, 4 Core. | Km | 188836.2 | 188836.2 | 0.2 | False | None | None | False | None | False | 37767.24 | 0 |
2927946 | 96520 | None | RGU668 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 35 Sqmm, 3.5 Core. | Km | 161765.1 | 161765.1 | 0.4 | False | None | None | False | None | False | 64706.04 | 0 |
2927947 | 96520 | None | RGU669 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 50 Sqmm, 3.5 Core. | Km | 187921.65 | 187921.65 | 0.3 | False | None | None | False | None | False | 56376.495 | 0 |
2927948 | 96520 | None | RGU670 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 70 Sqmm, 3.5 Core. | Km | 333807.6 | 333807.6 | 0.1 | False | None | None | False | None | False | 33380.76 | 0 |
2927949 | 96520 | None | RGU671 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 95 Sqmm, 3.5 Core. | Km | 391875.75 | 391875.75 | 0.7 | False | None | None | False | None | False | 274313.025 | 0 |
2927950 | 96520 | None | RGU672 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 120 Sqmm, 3.5 Core. | Km | 479733.45 | 479733.45 | 0.2 | False | None | None | False | None | False | 95946.69 | 0 |
2927951 | 96520 | None | RGU673 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness in average +5percent and resistivity 14 OhmsKms Max as per IS3975 BESCOM SR 20232024 A2XFY 240 Sqmm, 3.5 Core. | Km | 905799.3 | 905799.3 | 0.6 | False | None | None | False | None | False | 543479.58 | 0 |
2927952 | 96520 | None | RGU674 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers asdirected by the departmental staff 2.5 to 25 Sqmm | Km | 21930.3 | 21930.3 | 1.5 | False | None | None | False | None | False | 32895.45 | 0 |
2927953 | 96520 | None | RGU675 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers asdirected by the departmental staff 35 to 95 Sqmm | Km | 32695.95 | 32695.95 | 1.5 | False | None | None | False | None | False | 49043.925 | 0 |
2927954 | 96520 | None | RGU676 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers asdirected by the departmental staff 120 to 240 Sqmm | Km | 33891.9 | 33891.9 | 0.8 | False | None | None | False | None | False | 27113.52 | 0 |
2927955 | 96520 | None | RGU677 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 4X10 Sq. mm 25 mm | Each | 282.45 | 282.45 | 80.0 | False | None | None | False | None | False | 22596.0 | 0 |
2927956 | 96520 | None | RGU678 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 4X16 Sq. mm 28 mm | Each | 324.45 | 324.45 | 40.0 | False | None | None | False | None | False | 12978.0 | 0 |
2927957 | 96520 | None | RGU679 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 4X25 Sq. mm 28 mm | Each | 330.75 | 330.75 | 14.0 | False | None | None | False | None | False | 4630.5 | 0 |
2927958 | 96520 | None | RGU680 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 3.5X35 Sq. mm 32 mm | Each | 387.45 | 387.45 | 10.0 | False | None | None | False | None | False | 3874.5 | 0 |
2927959 | 96520 | None | RGU681 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 3.5X50 Sq. mm 35 mm | Each | 433.65 | 433.65 | 6.0 | False | None | None | False | None | False | 2601.9 | 0 |
2927960 | 96520 | None | RGU682 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 3.5X70 Sq. mm 38 mm | Each | 491.4 | 491.4 | 4.0 | False | None | None | False | None | False | 1965.6 | 0 |
2927961 | 96520 | None | RGU683 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 3.5X120 Sq. mm 45 mm | Each | 643.65 | 643.65 | 6.0 | False | None | None | False | None | False | 3861.9 | 0 |
2927962 | 96520 | None | RGU684 | MV CABLE JOINTING and END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 3.5X240 Sq. mm 62 mm | Each | 1078.35 | 1078.35 | 26.0 | False | None | None | False | None | False | 28037.1 | 0 |
2927963 | 96520 | None | RGU685 | Heavy Duty Copper Terminal Long Barrel 35 Sqmm Copper Terminal, Apprx Wt: 17 Gm | Nos | 42.0 | 42.0 | 56.0 | False | None | None | False | None | False | 2352.0 | 0 |
2927964 | 96520 | None | RGU686 | Heavy Duty Copper Terminal Long Barrel 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm | Nos | 60.9 | 60.9 | 24.0 | False | None | None | False | None | False | 1461.6 | 0 |
2927965 | 96520 | None | RGU687 | Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm | Nos | 93.45 | 93.45 | 24.0 | False | None | None | False | None | False | 2242.8 | 0 |
2927966 | 96520 | None | RGU688 | Heavy Duty Copper Terminal Long Barrel 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm | Nos | 147.0 | 147.0 | 50.0 | False | None | None | False | None | False | 7350.0 | 0 |
2927967 | 96520 | None | RGU689 | Heavy Duty Copper Terminal Long Barrel 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm | Nos | 372.75 | 372.75 | 50.0 | False | None | None | False | None | False | 18637.5 | 0 |
2927968 | 96520 | None | RGU690 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 3685.5 | 3685.5 | 34.0 | False | None | None | False | None | False | 125307.0 | 0 |
2927969 | 96520 | None | RGU691 | Supplying and Fixing Chemical earthling for grounding. Conduits, IC cutouts and other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm Using 4ft. Copper bonded rod with backfill compound | Kit | 4754.4 | 4754.4 | 4.0 | False | None | None | False | None | False | 19017.6 | 0 |
2927970 | 96520 | None | RGU692 | Supplying and Fixing Chemical earthling for grounding. Conduits, IC cutouts and other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm Using 10ft. Copper bonded rod with backfill compound | Kit | 8918.7 | 8918.7 | 4.0 | False | None | None | False | None | False | 35674.8 | 0 |
2927971 | 96520 | None | RGU693 | Supplying and running of GICopper strips for grounding connections, using necessary fixing materials as required. GICopper Strips 25x3mm GI strip In Cable Trays and All Electrical Equipments. | Mtr | 86.1 | 86.1 | 750.0 | False | None | None | False | None | False | 64575.0 | 0 |
2927972 | 96520 | None | RGU694 | Supplying and running of GICopper strips for grounding connections, using necessary fixing materials as required. GICopper Strips 25x6mm GI strip Sub Panels | Mtr | 134.4 | 134.4 | 200.0 | False | None | None | False | None | False | 26880.0 | 0 |
2927973 | 96520 | None | RGU695 | Supplying and running of GICopper strips for grounding connections, using necessary fixing materials as required. GICopper Strips 40x6mm GI strip Main LT Panel | Mtr | 190.05 | 190.05 | 45.0 | False | None | None | False | None | False | 8552.25 | 0 |
2927974 | 96520 | None | RGU696 | Supplying and running of GICopper strips for grounding connections, using necessary fixing materials as required. GICopper Strips 600x600x3mm GI Plate Body Earthing | Each | 918.75 | 918.75 | 22.0 | False | None | None | False | None | False | 20212.5 | 0 |
2927975 | 96520 | None | RGU697 | Supplying and running of GICopper strips for grounding connections, using necessary fixing materials as required. GICopper Strips 25x3mm Copper strip 2 runs UPS,EPABX,Server room and Lab Equipments. | Mtr | 598.5 | 598.5 | 500.0 | False | None | None | False | None | False | 299250.0 | 0 |
2927976 | 96520 | None | RGU698 | Supplying and running of GICopper strips for grounding connections, using necessary fixing materials as required. GICopper Strips 600x600x3mm Copper plate | Each | 7792.05 | 7792.05 | 12.0 | False | None | None | False | None | False | 93504.6 | 0 |
2927977 | 96520 | None | RGU699 | Aircraft warning lights with Photosenser cell for dusk and down control | Each | 11500.0 | 11500.0 | 1.0 | False | None | None | False | None | False | 11500.0 | 0 |
2927978 | 96520 | None | RGU700 | ESE LIGHTNING ARRESTER Supply and installation of ESE lightning air terminal with the below technical Parameters. Stainless Steel material 304 L suitable for corrosive Environments. delta T = 15 micro seconds.METU lab tested as per NF C 17102 2011 standard. Lightning current = 100 KA 10350 micro sec tested. Protection radius = 107 Meter CPRI TESTED. | Each | 85000.0 | 85000.0 | 1.0 | False | None | None | False | None | False | 85000.0 | 0 |
2927979 | 96520 | None | RGU701 | ESE LIGHTNING ARRESTER MAST POLE ACCESSORIES Supply and installation of GI Mast Pole 5meter length with below accessories GI Mast pole 5 meter 01 No GI Base Plate 1feetx1feet HDP Adaptor 01 No GI Base Plate 1feetx1feet HDP Adaptor 01 No Guy Wire kit 20 meter Anchor Fastener 04 Nos Guy Wire Hook 03 Nos | Each | 32750.0 | 32750.0 | 1.0 | False | None | None | False | None | False | 32750.0 | 0 |
2927980 | 96520 | None | RGU702 | LIGHTNING ELECTRO MECHANICAL COUNTER Supply and installation of lightning event counter with the below technical parameters. 6 digits Counter Non resettable Electromechanical display IP 65 protection IEC 529 Lightning Current of 100 KA. | Each | 23500.0 | 23500.0 | 1.0 | False | None | None | False | None | False | 23500.0 | 0 |
2927981 | 96520 | None | RGU703 | IP 65 TEST LINK BOX Supply and installation of Test link box withcopper test link inside the IP 65protected box | Each | 4920.0 | 4920.0 | 1.0 | False | None | None | False | None | False | 4920.0 | 0 |
2927982 | 96520 | None | RGU704 | COPPER EARTH KITMAINTENANCE FREE ADVANCE EARTHING Supply of Maintenance free earthing system of 01 no of Copper Earth rod 17.2mm with flat terminal connection EARTH ROD SPECIFICATION Technology = Copper Bonded Rod Length of the electrode = 2000 mm 2 Mtrs Rod Dia= 17.2mm Dia BACK FILL COMPOUND Supply of Earthing back fill compound manufactured as per complying with the international standard IEEE 802000.Earthing Chemical compound is certified from BIS and NABL accredited laboratory as per IEEE 802000 Clause 14.5d .Certification Test certificate from BIS Bureau of Indian Standards , Govt of India accredited laboratory confirming the contents. IEEE802000 standard Test certificate from NABL, BIS, DGS andD, MOEF, DGQA accredited laboratory as per IEEE802000 clause 14.5 d. Moisture retaining capacity pH Value Between 7 to 7.2 ROHS certified. Weight = 25KG BAG | Each | 13500.0 | 13500.0 | 12.0 | False | None | None | False | None | False | 162000.0 | 0 |
2927983 | 96520 | None | RGU705 | Supply of 20 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : Digital Technology Three Phase Input, Three Phase Output With bidirectional Static and manual bypass Switch .Hot swipable. | No | 400000.0 | 400000.0 | 2.0 | False | None | None | False | None | False | 800000.0 | 0 |
2927984 | 96520 | None | RGU706 | Software monitoringBMS ServicePer Battery | No | 20000.0 | 20000.0 | 2.0 | False | None | None | False | None | False | 40000.0 | 0 |
2927985 | 96520 | None | RGU707 | Cables between UPS and Batteries [5 Mtrs. Max] | No | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2927986 | 96520 | None | RGU708 | Installation and commissioning charges. | No | 10000.0 | 10000.0 | 2.0 | False | None | None | False | None | False | 20000.0 | 0 |
2927987 | 96520 | None | RGU709 | Supply of 30 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : Digital Technology Three Phase Input, Three Phase Output With Static with static by pass.switch . | No | 850000.0 | 850000.0 | 2.0 | False | None | None | False | None | False | 1700000.0 | 0 |
2927988 | 96520 | None | RGU710 | Software monitoringBMS ServicePer Battery | No | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2927989 | 96520 | None | RGU711 | Cables between UPS and Batteries [5 Mtrs. Max] | No | 25000.0 | 25000.0 | 2.0 | False | None | None | False | None | False | 50000.0 | 0 |
2927990 | 96520 | None | RGU712 | Installation and commissioning charges. | No | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2927991 | 96520 | None | RGU713 | Supply of 10 KVA UNINTERRUPTED POWER SUPPLY SYSTEM with Moudular type : Digital Technology Three Phase Input, Three Phase Output With bidirectional Static and manual bypass Switch .Hot swipable. | No | 225000.0 | 225000.0 | 2.0 | False | None | None | False | None | False | 450000.0 | 0 |
2927992 | 96520 | None | RGU714 | Software monitoringBMS ServicePer Battery | No | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2927993 | 96520 | None | RGU715 | Cables between UPS and Batteries [5 Mtrs. Max] | No | 15000.0 | 15000.0 | 2.0 | False | None | None | False | None | False | 30000.0 | 0 |
2927994 | 96520 | None | RGU716 | Installation and commissioning charges. | No | 10000.0 | 10000.0 | 2.0 | False | None | None | False | None | False | 20000.0 | 0 |
2927995 | 96520 | None | RGU717 | LIFT WORKS Design, supplying, erecting testing and commissioning of passenger Bedcumpassenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V3 phase 50 cycles AC supply, powder coated Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening side opening door with orwithout attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc. with back ground music system. D. With Out Machine RoomSS Finish LIFT WORKS Design, supplying, erecting testing and commissioning of passenger Bedcumpassenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V3 phase 50 cycles AC supply, powder coated Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening side opening door with orwithout attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc. with back ground music system. 20 Passengers 7 Stops | Nos | 3558310.89 | 3558310.89 | 2.0 | False | None | None | False | None | False | 7116621.78 | 0 |
2927996 | 96520 | None | RGU718 | Supplying and drawing UTPCAT 6E LAN cable. | Mtr | 39.9 | 39.9 | 15200.0 | False | None | None | False | None | False | 606480.0 | 0 |
2927997 | 96520 | None | RGU719 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 2 Pair | Mtr | 22.05 | 22.05 | 5040.0 | False | None | None | False | None | False | 111132.0 | 0 |
2927998 | 96520 | None | RGU720 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable 20 Pair | Mtr | 150.0 | 150.0 | 300.0 | False | None | None | False | None | False | 45000.0 | 0 |
2927999 | 96520 | None | RGU721 | Supplying and Fixing of sitch mountng rack with power manager and Cable manager 42U with 650mm depth | Each | 45326.4 | 45326.4 | 1.0 | False | None | None | False | None | False | 45326.4 | 0 |
2928000 | 96520 | None | RGU722 | Supplying and Fixing of sitch mountng rack with power manager and Cable manager 6U with 450mm depth | Each | 7325.85 | 7325.85 | 7.0 | False | None | None | False | None | False | 51280.95 | 0 |
2928001 | 96520 | None | RGU723 | Supplying and fixing of Networking Switches16 Port 101001000 Switch | Each | 6762.0 | 6762.0 | 8.0 | False | None | None | False | None | False | 54096.0 | 0 |
2928002 | 96520 | None | RGU724 | Supplying and fixing of Networking Switches24 Port 101001000 Switch | Each | 7785.75 | 7785.75 | 14.0 | False | None | None | False | None | False | 109000.5 | 0 |
2928003 | 96520 | None | RGU725 | Supplying and fixing of Networking Switches24 Port Gigabyte manageable | Each | 43522.5 | 43522.5 | 2.0 | False | None | None | False | None | False | 87045.0 | 0 |
2928004 | 96520 | None | RGU726 | Supplying and Fixing of Power strip | Each | 1529.85 | 1529.85 | 8.0 | False | None | None | False | None | False | 12238.8 | 0 |
2928005 | 96520 | None | RGU727 | Supplying of shelf | Each | 868.35 | 868.35 | 8.0 | False | None | None | False | None | False | 6946.8 | 0 |
2928006 | 96520 | None | RGU728 | Supplying and fixing of Castor wheels to the Shelf set of 4 | Each | 1661.1 | 1661.1 | 2.0 | False | None | None | False | None | False | 3322.2 | 0 |
2928007 | 96520 | None | RGU729 | Supplying and Fixing of Fan | Each | 1269.45 | 1269.45 | 10.0 | False | None | None | False | None | False | 12694.5 | 0 |
2928008 | 96520 | None | RGU730 | Supplying andfixing of IOsocket, face plate with back box Single IO | Each | 514.5 | 514.5 | 342.0 | False | None | None | False | None | False | 175959.0 | 0 |
2928009 | 96520 | None | RGU731 | Supplying andfixing of IOsocket, face plate with back box Double IO | Each | 577.5 | 577.5 | 112.0 | False | None | None | False | None | False | 64680.0 | 0 |
2928010 | 96520 | None | RGU732 | Supplying andfixing of 2mtr cat 6 Patch Cable | Each | 269.85 | 269.85 | 460.0 | False | None | None | False | None | False | 124131.0 | 0 |
2928011 | 96520 | None | RGU733 | Supplying andfixing of 3mtr cat 6 Patch Cable | Each | 347.55 | 347.55 | 460.0 | False | None | None | False | None | False | 159873.0 | 0 |
2928012 | 96520 | None | RGU734 | Supplying and Fixing of patch panel for LAN cabling 24 port 101001000 patch panel | Each | 8295.0 | 8295.0 | 16.0 | False | None | None | False | None | False | 132720.0 | 0 |
2928013 | 96520 | None | RGU735 | Supplying and Fixing of patch panel for LAN cabling 16 port 101001000 patch panel | Each | 8137.5 | 8137.5 | 8.0 | False | None | None | False | None | False | 65100.0 | 0 |
2928014 | 96520 | None | RGU736 | Supplying and fixing of MDF krone junction box with KRONE Module Telephone cable termination20 pair krone module with MDF BOX | Each | 402.15 | 402.15 | 1.0 | False | None | None | False | None | False | 402.15 | 0 |
2928015 | 96520 | None | RGU737 | Supplying and fixing of MDF krone junction box with KRONE Module Telephone cable termination50 pair krone module with MDF BOX | Each | 662.55 | 662.55 | 4.0 | False | None | None | False | None | False | 2650.2 | 0 |
2928016 | 96520 | None | RGU738 | 300 Pair Krone Module with MDF BOX | Each | 5000.0 | 5000.0 | 1.0 | False | None | None | False | None | False | 5000.0 | 0 |
2928017 | 96520 | None | RGU739 | Supply, Installation, Testing and Commissioning of 6 core single mode Armored Optic fibre cable OS1OS2 loose tube indooroutdoor Loose Tube 2.8 mm jelly filled loose tube with 224 fibres, Sheath 1,5 mm sheath, UV stabilised, IEC 50290227 Colour = Yellow Ral 1018, Fire Rating IEC 60332324 IEC 6033212 IEC 607541 EN50399, Nominal outer diameter 224 fibres : 7,3 mm, Min. Bending radius, unloaded E11 R = 73 mm, Min. Bending radius, loaded R=146, Temperature range Operation : 30 degree C to 70 degree C. Standards and Norms IEC 60793250 category B.1.3 EN 60793250: class B1.3 ITU Recommendation G.652.D the other ITU designations A, B and C are also fulfilled. EN 50 1731:2007, cat. OS2, also OS1 requirements are fulfilled. ISOIEC 11801:2002, cat. OS1 ISOIEC 24702:2006, cat. OS2, also OS1 requirements are fulfilled IEEE 802.3 2002 incl. 802.3ae. | Mtr | 75.0 | 75.0 | 300.0 | False | None | None | False | None | False | 22500.0 | 0 |
2928018 | 96520 | None | RGU740 | Supply, Installation, Testing and Commissioning of 12 port LIU of 19inches slidein modular optic drawers with galvanised steel accommodates up to 4 fibre optic units, 4 cables, accommodates up to 12ST and SC connectors and 12 LC connectors. Should meet EN50173 and ISOIEC 11801 operating specifications.10 GB 9125 ohmm OS2 LC LSZH Pigtails confirming to ITUG651 and TIAEIA 492AAAA standards | Each | 15000.0 | 15000.0 | 1.0 | False | None | None | False | None | False | 15000.0 | 0 |
2928019 | 96520 | None | RGU741 | Supply, Installation, Testing and Commissioning of 6 port LIU of 19inches slidein modular optic drawers with galvanised steel accommodates up to 4 fibre optic units, 4 cables, accommodates up to 6ST and SC connectors and 6 LC connectors. Should meet EN50173 and ISOIEC 11801 operating specifications.10 GB 9125 ohmm OS2 LC LSZH Pigtails confirming to ITUG651 and TIAEIA 492AAAA standards | Each | 13000.0 | 13000.0 | 1.0 | False | None | None | False | None | False | 13000.0 | 0 |
2928020 | 96520 | None | RGU742 | Supply, Installation, Testing and Commissioning of LCLC Duplex Patch Cords OS2 2 mtr. The OFC patchcords provide flexible interconnection to active equipment, passive optical devices and crossconnects.. Maximum optical losses : 0.3 dB. IL MAXMaster Acceptance 0.3 dB as pe IEC 6130034, MAX ILRandom 0.4 dB as per IEC 61300334, Mechanical endurance 500 matings as per IEC 6130022. Connector type IEC 6175420 MM PC Beige with clips Boot white. Cable Material LSZHPVC. | Each | 2500.0 | 2500.0 | 10.0 | False | None | None | False | None | False | 25000.0 | 0 |
2928021 | 96520 | None | RGU743 | Supply, Installation, Testing and Commissioning of Sfp Module Single Mode as rquired | Each | 7500.0 | 7500.0 | 12.0 | False | None | None | False | None | False | 90000.0 | 0 |
2928022 | 96520 | None | RGU744 | 12Port Gigabit Fiber Metro Ethernet Switch, 2P101001000BASET RJ45 ports, 1G SFP ports, and 10G SFP+ ports,,increased network bandwidth. Surge protection, advanced Layer 2 functions | Each | 25000.0 | 25000.0 | 1.0 | False | None | None | False | None | False | 25000.0 | 0 |
2928023 | 96520 | None | RGU745 | Supply and Fixing of GbESpeed Wifi Router, PoE Support. | Each | 10000.0 | 10000.0 | 6.0 | False | None | None | False | None | False | 60000.0 | 0 |
2928024 | 96520 | None | RGU746 | 8 x 1001000 BaseT 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with SFP Transceiver Module x 2 Nos | Each | 14000.0 | 14000.0 | 1.0 | False | None | None | False | None | False | 14000.0 | 0 |
2928025 | 96520 | None | RGU747 | EPABX: Supply,Installation,Testing and Commissioning of microprocessor based, state of the Art, Telephone PBX System , IP READY,based on LinuxGRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 150 Ports Providing PRI cards for Trunk lines for tie line with reqd.software 8Analog Trunk Lines 8 Digital Extensions 300 Analogue Extensions Expandable up to 400 InBuilt Voicemail 4 Port and 80 Min LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold | Each | 725000.0 | 725000.0 | 1.0 | False | None | None | False | None | False | 725000.0 | 0 |
2928026 | 96520 | None | RGU748 | TELEPHONES Analog push button telephone with Caller ID, flash and radial | Each | 1850.0 | 1850.0 | 110.0 | False | None | None | False | None | False | 203500.0 | 0 |
2928027 | 96520 | None | RGU749 | TELEPHONES Digital Phones | Each | 7500.0 | 7500.0 | 2.0 | False | None | None | False | None | False | 15000.0 | 0 |
2928028 | 96520 | None | RGU750 | Supply,Installation,Testing and Commissioning of Facial Recognition , Biometric and Card. Dual Core 1.2Ghz Processor, Linux Operating System, Verification time 1 Second, 0.52Mtrs recognition distance, 512MB RAM, 8GB ROM, Communication WIFI,TCPIP, USB, Wiegand INOUT, Power 12V2A | Nos | 38000.0 | 38000.0 | 4.0 | False | None | None | False | None | False | 152000.0 | 0 |
2928029 | 96520 | None | RGU751 | Supply and Fixing of T and A Software | Nos | 50000.0 | 50000.0 | 1.0 | False | None | None | False | None | False | 50000.0 | 0 |
2928030 | 96520 | None | RGU752 | Supplying and drawing UTPCAT 6E LAN cable | Rmtr | 39.9 | 39.9 | 120.0 | False | None | None | False | None | False | 4788.0 | 0 |
2928031 | 96520 | None | RGU753 | Supply, Installation, Testing and Commissioning of 4MP Lite IR Fixedfocal Dome Network Camera , 13in CMOS image sensor, low illuminance, high image definition Outputs 4MP 2560 x 1440 at2530 fps, max. supports 4MP 2688 x1520 at 20 fps,H.265 codec, high compression rate, ultralow bit rate Builtin IR LED, max IR distance: 40 m, ROI, SMART H.264+H.265+, flexible coding, applicable to various bandwidth and storage environment Rotation mode, WDR, 3D NR, HLC, BLC, digital watermarking, applicable to various monitoring scenes,Intelligent detection: Intrusion, tripwire,Abnormality detection: Motion detection, video tampering, no SD card,SD card full, SD card error, network disconnected, IP conflict, illegal access, voltage detection, Supports max. 256 GB Micro SD card,Inbuilt 64 GB micro SD card,12V DCPoE power supply IP67, IK10 protectionThe prices should include the necessary mounts and brackets. | Each | 10500.0 | 10500.0 | 96.0 | False | None | None | False | None | False | 1008000.0 | 0 |
2928032 | 96520 | None | RGU754 | Supply, Installation, Testing and Commissioning of 4MP IP Indoor Dome VF Camera with 1 2.8in CMOS Image Sensor , 2.7mm 13.5mm Motorized lens, 2688 H x 1520 V resolution, 0.008 Lux at F1.5, IR Illumination Up to 40m IR Distance, BLC, HLC, WDR, White Balance: Auto, Natural, Street Lamp, Outdoor, Manual, Customized Region , 3D DNR Noise Reduction, Privacy Masking, ROI, H.265H.264MJpeg Compression, Dual Stream, Motion Detection, Video Tampering, Tripwire Intrusion Analytics, RJ 45 10100Base T , IPv4, IPv6, HTTP, TCP, UDP, ARP, RTP , RTSP, RTCP, RTMP, SMTP, FTP, SFTP, DHCP, DNS, DDNS, QoS, UPnP, NTP, Multicast, ICMP, IGMP, NFS, PPPoE, Bonjour. Cyber security: Video encryption, firmware encryption, configuration encryption, Digest, WSSE, account lockout, security logs, IPMAC filtering, generation and importing of X.509 certification, syslog, HTTPS, 802.1x, trusted boot, trusted execution, trusted upgrade. Alarm events: No SD card, SD card full, SD card error, network disconnection, IP conflict, motion detection, video tampering, tripwire, intrusion, illegal access, voltage detection, audio detection, safety exception, local alarm. 1 channel RCA port Audio In, 1 channel RCA port Audio Out, Alaram Inout: 11, Supports max. 256 GB Micro SD card. DC12V, PoE 802.3 af Class 0 IP67, IK10, CE, FCC,UL. 30 degree C 60 degree C Operating Temperature | Each | 18000.0 | 18000.0 | 19.0 | False | None | None | False | None | False | 342000.0 | 0 |
2928033 | 96520 | None | RGU755 | Supply,Installation,Testing andCommissioningof 5MP WDR IR Bullet WizMind Network Camera ,12.7in 5Megapixel progressive scan CMOS, ROI, SMART H.264+H.265+, flexible coding, applicable to various bandwidth and storage environments,20 fpsat2592 x 1944, 5060 fpsat1080P 1920 x 1080 ,WDR 120 dB , DayNight ICR , 3D DNR, AWB, AGC, BLCMultiple network monitoring: Web viewer, CMS DSSPSS and DMSS ,2.8 mm fixed lens 3.6 mm, 6.0 mm optional ,11 Alarm inout, 11 audio inout,Max. IR LEDs Length 50m,Micro SD memory, IP67, IK10,Builtin micro SDSDHCSDXC card slot,up to 128 GB Inbuilt 64 GB micro SD card, DC12V, PoE 802.3 af Class 0 , IK10 Vanidal Resistance, The prices should include the necessary mounts and brackets. | Each | 17000.0 | 17000.0 | 6.0 | False | None | None | False | None | False | 102000.0 | 0 |
2928034 | 96520 | None | RGU756 | Supply, Installation and Commissioning of 4MP IP PTZ camera with 13inchesCMOS Sensor 30X Optical Zoom 16X Digital Zoom 120dB WDR Color: 0.05 Lux at F1.6 0 Lux at F1.6 IR on IR Illumination focal length 4.5 mm 135 mm Apperture F1.6 F4.4 IR Distance UPTO 100Mtr, Video compression H.265MJPEGH.264 Video Streaming triple streams Resolution 4 MP 2592 x 1520 , RJ45,10100 Mbps Ethernet IPv4v6, TCPIP, ONVIF 20 users supports 128 GB MicroSD Card nbuilt 64 GB micro SD card, ONVIF Profile S 24 VAC, 3 A 10percent , PoE+ 802.3at class 4,The prices should include the necessary mounts and brackets. | Each | 99500.0 | 99500.0 | 2.0 | False | None | None | False | None | False | 199000.0 | 0 |
2928035 | 96520 | None | RGU757 | NETWORK VIDEO RECORDER NVR :Supply, Installation, Testing and Commissioning of 32ch NVR with Industrial embedded microprocessor, Embedded Linux operating system, 320 Mbps bandwidth, supporting resolution 12MP, 8MP, 6MP, 5MP, 4MP, 3MP, 1080p, 1.3MP, 720p, D1, and more, Smart H.265+, Smart H.264+, H.265, H.264, MJPEG compression, HTTP, HTTPS, TCPIP, IPv4IPv6, UPnP, SNMP, RTSP, UDP, SMTP, NTP, DHCP, DNS, IP Filter, PPPoE, DDNS, FTP, Alarm Server, IP Search, P2P protocols supporting, ONVIF profile TSG , Manual, schedule record modes, disk group options, should supports analytics features of the cameras like, perimeter protection, face detection, ANPR, Video metadata, Audio ports inout: 12, Alarm ports inout: 166, should support 4 SATA III ports, up to 10 TB for a single HDD, eSATA, RS232, RS485, 1 front USB 2.0 port, 2 rear USB 3.0 port, 2 HDMI, 2 VGA, 2 RJ45 101001000 Mbps selfadaptive Ethernet port, 10 degree C to +55 degree C +14 degree F to +131 degree F , CE, FCC, UL cirtified. | Each | 55000.0 | 55000.0 | 4.0 | False | None | None | False | None | False | 220000.0 | 0 |
2928036 | 96520 | None | RGU758 | 4TB HDD Surveillance or Enterprise Grade | Each | 15000.0 | 15000.0 | 16.0 | False | None | None | False | None | False | 240000.0 | 0 |
2928037 | 96520 | None | RGU759 | 24P x 1001000 GbE BaseT 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 degree operating temperature support | Each | 25000.0 | 25000.0 | 6.0 | False | None | None | False | None | False | 150000.0 | 0 |
2928038 | 96520 | None | RGU760 | 16P x 1001000 GbE BaseT 802.3at supported PoE+ Ports + 2 x 1GbE SFP Ports Managed Switch with Layer 2+ Image, 50 degree operating temperature support | Each | 25000.0 | 25000.0 | 1.0 | False | None | None | False | None | False | 25000.0 | 0 |
2928039 | 96520 | None | RGU761 | Supplying and Fixing of patch panel for LAN cabling 24 port 101001000 patch panel | Each | 8295.0 | 8295.0 | 7.0 | False | None | None | False | None | False | 58065.0 | 0 |
2928040 | 96520 | None | RGU762 | Supplying andfixing of 1mtr cat 6 Patch Cable | Each | 235.2 | 235.2 | 125.0 | False | None | None | False | None | False | 29400.0 | 0 |
2928041 | 96520 | None | RGU763 | Category 6 Field termination Plug with 4 x 4 PVC boxes | Each | 165.0 | 165.0 | 123.0 | False | None | None | False | None | False | 20295.0 | 0 |
2928042 | 96520 | None | RGU764 | Supplying and Fixing of sitch mountng rack with power manager and Cable manager 6U with 450mm depth | Each | 7325.85 | 7325.85 | 5.0 | False | None | None | False | None | False | 36629.25 | 0 |
2928043 | 96520 | None | RGU765 | Supplying and Fixing of sitch mountng rack with power manager and Cable manager 27U with 650mm depth | Each | 33755.4 | 33755.4 | 1.0 | False | None | None | False | None | False | 33755.4 | 0 |
2928044 | 96520 | None | RGU766 | Supplying and Fixing of Power strip | Each | 1529.85 | 1529.85 | 6.0 | False | None | None | False | None | False | 9179.1 | 0 |
2928045 | 96520 | None | RGU767 | Supplying of shelf | Each | 868.35 | 868.35 | 6.0 | False | None | None | False | None | False | 5210.1 | 0 |
2928046 | 96520 | None | RGU768 | Supplying and Fixing of Fan | Each | 1269.45 | 1269.45 | 6.0 | False | None | None | False | None | False | 7616.7 | 0 |
2928047 | 96520 | None | RGU769 | Supplying and drawing UTPCAT 6E LAN cable. | Mtr | 39.9 | 39.9 | 5350.0 | False | None | None | False | None | False | 213465.0 | 0 |
2928048 | 96520 | None | RGU770 | Supplying and Fixing of 42inches HD TV with HDMI Cable and Acessories Fixing option Wall Mount and Table Mount both option required | Each | 55000.0 | 55000.0 | 4.0 | False | None | None | False | None | False | 220000.0 | 0 |
2928049 | 96520 | None | RGU771 | SFP Single mode Gbs tranceiver module | Each | 5000.0 | 5000.0 | 8.0 | False | None | None | False | None | False | 40000.0 | 0 |
2928050 | 96520 | None | RGU772 | Supply, Installation, Testing and Commissioning of 6core OFC Armoured outdoor cable SM | Mtr | 195.0 | 195.0 | 160.0 | False | None | None | False | None | False | 31200.0 | 0 |
2928051 | 96520 | None | RGU773 | Supply and Installation of Fiber Optic Patch Chord for OFC Cable The rate shall include all mounting accessories complete as required etc., | Nos | 4500.0 | 4500.0 | 7.0 | False | None | None | False | None | False | 31500.0 | 0 |
2928052 | 96520 | None | RGU774 | Supply and Installation of 6P LIU For OFC Cable Termination The rate shall include all mounting accessories complete as required etc | Nos | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
2928053 | 96520 | None | RGU775 | Fiber Termination box | Nos | 600.0 | 600.0 | 5.0 | False | None | None | False | None | False | 3000.0 | 0 |
2928054 | 96520 | None | RGU776 | Supplying and fixing of modular switch socket stepped electronic fan regulator's dimmer telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV socket | Each | 163.8 | 163.8 | 5.0 | False | None | None | False | None | False | 819.0 | 0 |
2928055 | 96520 | None | RGU777 | Supplying and Fixing of 32inches HD TV | Each | 35000.0 | 35000.0 | 4.0 | False | None | None | False | None | False | 140000.0 | 0 |
2928056 | 96520 | None | RGU778 | Supplying and Fixing of 42inches HD TV | Each | 55000.0 | 55000.0 | 1.0 | False | None | None | False | None | False | 55000.0 | 0 |
2928057 | 96520 | None | RGU779 | Supplying and drawing PVC insulated gas injected physicalfoam jelly flooded coaxial TV cable.RG6. | Mtr | 46.2 | 46.2 | 350.0 | False | None | None | False | None | False | 16170.0 | 0 |
2928058 | 96520 | None | RGU780 | Supply and fixing of booster amplifier | Each | 7850.0 | 7850.0 | 2.0 | False | None | None | False | None | False | 15700.0 | 0 |
2928059 | 96520 | None | RGU781 | Supply and fixing of 3 way splitter | Each | 850.0 | 850.0 | 4.0 | False | None | None | False | None | False | 3400.0 | 0 |
2928060 | 96520 | None | RGU782 | Supply and Installation of 6W RMSWall Mount Cabinet Speaker with power taps at 642 on 100V, 6015,000 Hz with all Accessories, | Each | 1882.65 | 1882.65 | 100.0 | False | None | None | False | None | False | 188265.0 | 0 |
2928061 | 96520 | None | RGU783 | Supply and Installation of 6W RMS Ceiling Mount Speaker with power taps at 642 on 100V, 6015,000 Hz with all Accessories, | Each | 1013.25 | 1013.25 | 10.0 | False | None | None | False | None | False | 10132.5 | 0 |
2928062 | 96520 | None | RGU784 | Supply, Installation, Testing and commissioning of Public Address System 6 Zone Voice Alarm controller Preamplifier Mixer amplifer, Inbuilt 240W Amplifier, Auto fire evacualtion message with USB MP3 AM FM CAT 6 connectivity for Mic | Each | 132731.55 | 132731.55 | 1.0 | False | None | None | False | None | False | 132731.55 | 0 |
2928063 | 96520 | None | RGU785 | Supply, Installation, Testing and commissioning of Power Amplifier 400 W | Each | 45000.0 | 45000.0 | 2.0 | False | None | None | False | None | False | 90000.0 | 0 |
2928064 | 96520 | None | RGU786 | Supply, Installation, testing and Commissioning of Voice Command Keypad 6 Zone, with microphone assembley complete as required. | Nos | 85843.8 | 85843.8 | 1.0 | False | None | None | False | None | False | 85843.8 | 0 |
2928065 | 96520 | None | RGU787 | Supply and Installation of 2Cx1.5 Sqmm transprent annealead plain flexible electrolytic grade copper wire and acessories | Each | 56.7 | 56.7 | 2300.0 | False | None | None | False | None | False | 130410.0 | 0 |
2928066 | 96520 | None | RGU788 | Supplying and drawing UTPCAT 6E LAN cable | Mtr | 39.9 | 39.9 | 120.0 | False | None | None | False | None | False | 4788.0 | 0 |
2928067 | 96520 | None | RGU789 | Supplying and Fixing of sitch mountng rack with power manager and Cable manager 12U with 450mm depth | Each | 9276.75 | 9276.75 | 1.0 | False | None | None | False | None | False | 9276.75 | 0 |
2928068 | 96520 | None | RGU790 | Supplying and Fixing of Power strip | Each | 1529.85 | 1529.85 | 1.0 | False | None | None | False | None | False | 1529.85 | 0 |
2928069 | 96520 | None | RGU791 | Supplying of shelf | Each | 868.35 | 868.35 | 2.0 | False | None | None | False | None | False | 1736.7 | 0 |
2928070 | 96520 | None | RGU792 | Supplying and Fixing of Fan | Each | 1269.45 | 1269.45 | 1.0 | False | None | None | False | None | False | 1269.45 | 0 |
2928071 | 96520 | None | RGU793 | Supply, Installation, testing and commissioning of View Board 75inches 4K Interactive Display, my View Board suite with whiteboard, wireless casting and remote device management, Front facing dual speakers for better engagemenT,Pen on paper writing experience with Ultra Fine Touch , TFT LCD Module with DLED Backlight, Display Area mm 1650.24mm H x 928.26mm V 74.6in diagonal ,Resolution UHD 3840x2160 Pixels, RAM2GB DDR4 ,Storage 16GB,Ultra Fine Touch Technology,20 points touch, 2 points writing, HDMI: 2.0x2 3840x2160 at60Hz ,Audio: x1 PC audio in ,10Wx2 subwoofers,Android 9 Viewsonic Maxsub | Nos | 575000.0 | 575000.0 | 4.0 | False | None | None | False | None | False | 2300000.0 | 0 |
2928072 | 96520 | None | RGU794 | Supply and Installation of Rack Mounted 70 watt PA mixing Amplifier, 2Mic and 1 Aux Input | Nos | 12000.0 | 12000.0 | 4.0 | False | None | None | False | None | False | 48000.0 | 0 |
2928073 | 96520 | None | RGU795 | Supply, Installation, testing and Commissioning of Wireless head Collar Mic, VHFUHF Economical Wireless Microphone Transmitter and receiver with selectable carrier Frequency from VHFUHF. | Set | 10000.0 | 10000.0 | 4.0 | False | None | None | False | None | False | 40000.0 | 0 |
2928074 | 96520 | None | RGU796 | Supply, Installation, testing and Commissioning of 1.53 6W wall Speaker Complete as required | Nos | 1882.65 | 1882.65 | 4.0 | False | None | None | False | None | False | 7530.6 | 0 |
2928075 | 96520 | None | RGU797 | Supplying and Fixing of switch mounting rack with power manager and Cable manager 6U With 450mm depth | Nos | 7325.85 | 7325.85 | 4.0 | False | None | None | False | None | False | 29303.4 | 0 |
2928076 | 96520 | None | RGU798 | Supplying and Fixing of Power strip | Nos | 1529.85 | 1529.85 | 4.0 | False | None | None | False | None | False | 6119.4 | 0 |
2928077 | 96520 | None | RGU799 | Supplying of shelf | Nos | 868.35 | 868.35 | 4.0 | False | None | None | False | None | False | 3473.4 | 0 |
2928078 | 96520 | None | RGU800 | Speaker Cable singlr pair, 2Core X 1.5sqmm | Mtr | 56.7 | 56.7 | 250.0 | False | None | None | False | None | False | 14175.0 | 0 |
2928079 | 96520 | None | RGU801 | Supply of Hi Speed HDMI Cable 15Mtrs | Each | 3500.0 | 3500.0 | 4.0 | False | None | None | False | None | False | 14000.0 | 0 |
2928080 | 96520 | None | RGU802 | Supply of Audio Video Cable,AUDIOUSB Single Gang Wall Box Face Plate with Pigtails Cable Acessories, Face plate with HDMI and USB Connectivity, with all kind of Connecting Patch Cables with Acessories | Job | 8000.0 | 8000.0 | 4.0 | False | None | None | False | None | False | 32000.0 | 0 |
2928081 | 96520 | None | RGU803 | Supply, Installation, Testing and Commissioning of 5000 ANSI Lumens, Full HD 1920x1080, Laser Light Source, 20000 hours lamp life, 2xHDMI connectivity, Aspect Ratio 16:9 format, Ceiling Mount Bracket , 2 Years Warranty. ViewsonicChristie | Nos | 310000.0 | 310000.0 | 1.0 | False | None | None | False | None | False | 310000.0 | 0 |
2928082 | 96520 | None | RGU804 | Supply, Installation, testing and commissioning of motorised Projector screen white colour, as per the class requirement. | Nos | 15000.0 | 15000.0 | 1.0 | False | None | None | False | None | False | 15000.0 | 0 |
2928083 | 96520 | None | RGU805 | 50inches 4k Ultra HD, Smart , Commercial Grade IPS Panel, 400nits brightness,HDMI X 3, RS 232, RJ45,USB, 10W X 2 in Built Speaker, in Built Browser, wifi, Screen share,CMS template with Universal flatscreen Wall Mount. LGSamsungEqui | Nos | 80000.0 | 80000.0 | 1.0 | False | None | None | False | None | False | 80000.0 | 0 |
2928084 | 96520 | None | RGU806 | Supply , Installation, Testing and Commissioning of Professional 2way Speaker system to provide superb LF Response, Speaker maximum input Power 200W RMS, High efficency and long throw with Excellent sound intelligibility, 12inches full range dual cone speaker and a piezo horn tweeter, Frequency response 50 Hz 20 kHz, with Speaker Stand and Boxes. | Nos | 20000.0 | 20000.0 | 8.0 | False | None | None | False | None | False | 160000.0 | 0 |
2928085 | 96520 | None | RGU807 | Supply , Installation, Testing and Commissioning of Dual channel Power Amplifier, 1350 watts rated output,Continuous rated Power StereoMono, 8 ohms : 2 X 250W, 4 ohms : 2 X 475W, frequency response 2020,000HZ, Power Bandwidth 2020,000HZ, input impedence 10K Un balanced, 20K Balanced, High fidelity sound, power consumptions 1800VA at 240V 50Hz. | Nos | 35000.0 | 35000.0 | 2.0 | False | None | None | False | None | False | 70000.0 | 0 |
2928086 | 96520 | None | RGU808 | Audio Mixer: Supply , Installation, Testing and Commissioning of 4 to 6 channel, 4 Music line input mixer with 23 band semi parametric eq 2 bus and 2aux a stereo return | Nos | 14000.0 | 14000.0 | 1.0 | False | None | None | False | None | False | 14000.0 | 0 |
2928087 | 96520 | None | RGU809 | Wireless Microphone : Supply , Installation, Testing and Commissioning of High quality UHF band frequency duet Wireless Microphone,Display on Transmitter and Receiver for frequency indication,Individual channel output with level control and mix output,Two microphones can be used at the same time. Wireless Mic with head Colar | Nos | 15500.0 | 15500.0 | 2.0 | False | None | None | False | None | False | 31000.0 | 0 |
2928088 | 96520 | None | RGU810 | Supply and Installation of Paging Table Top Microphone with Acessories AhujaBosch | Nos | 12000.0 | 12000.0 | 1.0 | False | None | None | False | None | False | 12000.0 | 0 |
2928089 | 96520 | None | RGU811 | Supply of Podium Lectern Presentation Stand for Conference, Meetings, Events, Including Mic Stand and 230V AC Power Point. | Nos | 19000.0 | 19000.0 | 1.0 | False | None | None | False | None | False | 19000.0 | 0 |
2928090 | 96520 | None | RGU812 | Supply and Installation of 2C x 1.5 Sqmm speaker Cable | Mtr | 56.7 | 56.7 | 500.0 | False | None | None | False | None | False | 28350.0 | 0 |
2928091 | 96520 | None | RGU813 | Supplying and Fixing of switch mounting rack with power manager and Cable manager 27U with 650mm depth | Each | 33755.4 | 33755.4 | 1.0 | False | None | None | False | None | False | 33755.4 | 0 |
2928092 | 96520 | None | RGU814 | Supplying and Fixing of Power strip | Nos | 1529.85 | 1529.85 | 1.0 | False | None | None | False | None | False | 1529.85 | 0 |
2928093 | 96520 | None | RGU815 | Supplying of shelf | Nos | 868.35 | 868.35 | 2.0 | False | None | None | False | None | False | 1736.7 | 0 |
2928094 | 96520 | None | RGU816 | Supply of High Speed HDMI Cable 30Mtrs | Each | 8000.0 | 8000.0 | 1.0 | False | None | None | False | None | False | 8000.0 | 0 |
2928095 | 96520 | None | RGU817 | Supply of Hi Speed HDMI Cable 15Mtrs | Each | 3500.0 | 3500.0 | 1.0 | False | None | None | False | None | False | 3500.0 | 0 |
2928096 | 96520 | None | RGU818 | Supply of Audio Video Cable,AUDIOUSB Single Gang Wall Box Face Plate with Pigtails Cable Acessories, Face plate with HDMI and USB Connectivity, with all kind of Connecting Patch Cables with Acessories Podium to Ampifier Location, Projector to Amplifier Location , USB Cables with Connectors and Face palte, Podium as per the requirement. | Each | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
2928097 | 96520 | None | RGU819 | Supply, Installation, Testing and Commissioning of HD Projector 4500 ANSI Lumens, Full HD 1920x1080, LED Light Source, 30000 hours lamp life, IP5x sealed engine, 2xHDMI connectivity Ceiling Mount Bracket , 2 years Warranty. ViewsonicChristie | Nos | 175000.0 | 175000.0 | 41.0 | False | None | None | False | None | False | 7175000.0 | 0 |
2928098 | 96520 | None | RGU820 | Supply, Installation, testing and commissioning of motorised Projector screen white colour, as per the class requirement. | Nos | 15000.0 | 15000.0 | 41.0 | False | None | None | False | None | False | 615000.0 | 0 |
2928099 | 96520 | None | RGU821 | Supply and Installation of Rack Mounted 70 watt PA mixing Amplifier, 2Mic and 1 Aux Input. | Nos | 12000.0 | 12000.0 | 41.0 | False | None | None | False | None | False | 492000.0 | 0 |
2928100 | 96520 | None | RGU822 | Supply and Installation of 6W RMSWall Mount Cabinet Speaker with power taps at 642 on 100V, 6015,000 Hz with all Accessories, | Each | 1882.65 | 1882.65 | 82.0 | False | None | None | False | None | False | 154377.3 | 0 |
2928101 | 96520 | None | RGU823 | Supply and Installation of Cordless Microphone with Acessories AhujaBosch | Set | 10000.0 | 10000.0 | 1.0 | False | None | None | False | None | False | 10000.0 | 0 |
2928102 | 96520 | None | RGU824 | Supply, Installation, testing and Commissioning of Wireless head Collar Mic, VHFUHF Economical Wireless Microphone Transmitter and receiver with selectable carrier Frequency from VHFUHF. | Set | 10000.0 | 10000.0 | 41.0 | False | None | None | False | None | False | 410000.0 | 0 |
2928103 | 96520 | None | RGU825 | Supplying and Fixing of switch mounting rack with power manager and Cable manager of 6U Network Rack | Nos | 7325.85 | 7325.85 | 41.0 | False | None | None | False | None | False | 300359.85 | 0 |
2928104 | 96520 | None | RGU826 | Supplying and Fixing of Power strip | Nos | 1529.85 | 1529.85 | 41.0 | False | None | None | False | None | False | 62723.85 | 0 |
2928105 | 96520 | None | RGU827 | Supplying of shelf | Nos | 868.35 | 868.35 | 41.0 | False | None | None | False | None | False | 35602.35 | 0 |
2928106 | 96520 | None | RGU828 | Speaker Cable singlr pair, 2Core, 1.5sqmm | Mtr | 56.7 | 56.7 | 1874.0 | False | None | None | False | None | False | 106255.8 | 0 |
2928107 | 96520 | None | RGU829 | Supply of Hi Speed HDMI Cable 15Mtrs | Each | 3500.0 | 3500.0 | 41.0 | False | None | None | False | None | False | 143500.0 | 0 |
2928108 | 96520 | None | RGU830 | Supply of Audio Video Cable,AUDIOUSB Single Gang Wall Box Face Plate with Pigtails Cable Acessories, Face plate with HDMI and USB Connectivity, with all kind of Connecting Patch Cables with Acessories Podium to Ampifier Location, Projector to Amplifier Location , USB Cables with Connectors and Face palte, Podium as per the requirement. | Each | 8000.0 | 8000.0 | 41.0 | False | None | None | False | None | False | 328000.0 | 0 |
2928109 | 96520 | None | RGU831 | Providing 2 Pole Structrue at the Tapping Point Using RCC Pole DP Structure using RCC Pole 9 Mtr Long, 145 Kg WL Including Cost of Poles | Set | 27615.0 | 27615.0 | 1.0 | False | None | None | False | None | False | 27615.0 | 0 |
2928110 | 96520 | None | RGU832 | 11 kV, 45 KN Polymeric Insulator | Nos | 195.3 | 195.3 | 6.0 | False | None | None | False | None | False | 1171.8 | 0 |
2928111 | 96520 | None | RGU833 | Guy Set Complete with No. 15 Strain Insulator and Concreting materials | Set | 1851.15 | 1851.15 | 2.0 | False | None | None | False | None | False | 3702.3 | 0 |
2928112 | 96520 | None | RGU834 | Spiral Earth Electrode | Nos | 348.6 | 348.6 | 2.0 | False | None | None | False | None | False | 697.2 | 0 |
2928113 | 96520 | None | RGU835 | Guy concreting with Boulders, Mud and Sand | Nos | 262.5 | 262.5 | 2.0 | False | None | None | False | None | False | 525.0 | 0 |
2928114 | 96520 | None | RGU836 | CautionDanger Board | Nos | 241.5 | 241.5 | 1.0 | False | None | None | False | None | False | 241.5 | 0 |
2928115 | 96520 | None | RGU837 | Anti Climbing Device 12 Mtr GI Barbed Wire | Each | 137.55 | 137.55 | 2.0 | False | None | None | False | None | False | 275.1 | 0 |
2928116 | 96520 | None | RGU838 | 11 kV, 400 Amps Double Break GOS | Set | 23597.7 | 23597.7 | 1.0 | False | None | None | False | None | False | 23597.7 | 0 |
2928117 | 96520 | None | RGU839 | HFrame for mounting GOS | Nos | 4797.45 | 4797.45 | 1.0 | False | None | None | False | None | False | 4797.45 | 0 |
2928118 | 96520 | None | RGU840 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor RCC Pole 9 Mtr Long, 145 Kg WL | Nos | 9258.9 | 9258.9 | 1.0 | False | None | None | False | None | False | 9258.9 | 0 |
2928119 | 96520 | None | RGU841 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole 9 Mtr Long, 145 Kg WL | Set | 963.9 | 963.9 | 1.0 | False | None | None | False | None | False | 963.9 | 0 |
2928120 | 96520 | None | RGU842 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor DP Structure with RCC Pole 9 Mtr Long, 145 Kg WL | Set | 27636.0 | 27636.0 | 1.0 | False | None | None | False | None | False | 27636.0 | 0 |
2928121 | 96520 | None | RGU843 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor 11 kV, 5 KN Polymeric Pin Insulator 24 mm Dia FRP Rod | Nos | 215.25 | 215.25 | 72.0 | False | None | None | False | None | False | 15498.0 | 0 |
2928122 | 96520 | None | RGU844 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor 11 kV, 45 KN Polymeric Insulator | Nos | 195.3 | 195.3 | 6.0 | False | None | None | False | None | False | 1171.8 | 0 |
2928123 | 96520 | None | RGU845 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor Guy Set Complete with No. 15 Strain Insulator and Concreting materials | Set | 1851.15 | 1851.15 | 6.0 | False | None | None | False | None | False | 11106.9 | 0 |
2928124 | 96520 | None | RGU846 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor Rabbit ACSR Conductor | Km | 53124.75 | 53124.75 | 2.2 | False | None | None | False | None | False | 116874.45 | 0 |
2928125 | 96520 | None | RGU847 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor PG Clamps for Rabbit Conductor | Nos | 107.1 | 107.1 | 6.0 | False | None | None | False | None | False | 642.6 | 0 |
2928126 | 96520 | None | RGU848 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor Spiral Earth Electrode | Nos | 348.6 | 348.6 | 13.0 | False | None | None | False | None | False | 4531.8 | 0 |
2928127 | 96520 | None | RGU849 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor EG Stirrups with GI wire lacing | Set of 2 Nos | 457.8 | 457.8 | 12.0 | False | None | None | False | None | False | 5493.6 | 0 |
2928128 | 96520 | None | RGU850 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor Guy concreting with Boulders, Mud and Sand | Nos | 262.5 | 262.5 | 3.0 | False | None | None | False | None | False | 787.5 | 0 |
2928129 | 96520 | None | RGU851 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor CautionDanger Board | Nos | 241.5 | 241.5 | 4.0 | False | None | None | False | None | False | 966.0 | 0 |
2928130 | 96520 | None | RGU852 | Running Single Circuit 11 kV, 3 Phase Power Line On 9 Mtr Supports With An Average Span Of 40 Mtr Using RABBIT ACSR Conductor Anti Climbing Device 12 Mtr GI Barbed Wire | Each | 137.55 | 137.55 | 13.0 | False | None | None | False | None | False | 1788.15 | 0 |
2928131 | 96520 | None | RGU853 | ACSR conductor as per IS : 398 Part 21996 are the latest revision Rabbit ACSR 63.35 mm Al + 13.35 mm St , Std Wt.: 214 KgKM | Km | 53124.75 | 53124.75 | 0.3 | False | None | None | False | None | False | 15937.425 | 0 |
2928132 | 96520 | None | RGU854 | Guy Wire and GI Wire 710 SWG Guy Wire 73.251 mm Dia , Std Wt.: 128 KgKM | Mtr | 81087.3 | 81087.3 | 0.01 | False | None | None | False | None | False | 810.873 | 0 |
2928133 | 96520 | None | RGU855 | Guy Wire and GI Wire 8 SWG GI Wire 4.064 mm Dia , Std Wt.: 125 KgKM | Mtr | 78792.0 | 78792.0 | 0.01 | False | None | None | False | None | False | 787.92 | 0 |
2928134 | 96520 | None | RGU856 | Guy Wire and GI Wire GI Barbed Wire 12 SWG | Mtr | 97827.45 | 97827.45 | 0.01 | False | None | None | False | None | False | 978.2745 | 0 |
2928135 | 96520 | None | RGU857 | HG Fuse Unit as per IS5350 Part2 11 kV, HG Fuse Unit with Solid Core Insulator Dwg No. BESCOMGMQS andS21 Dtd 24.11.2018 | Set | 1309.35 | 1309.35 | 1.0 | False | None | None | False | None | False | 1309.35 | 0 |
2928136 | 96520 | None | RGU858 | Lightning Arrester as per IEC600994 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR Dwg No. BESCOMGMQS andS26 Dtd 24.10.2007 | Set | 1090.95 | 1090.95 | 1.0 | False | None | None | False | None | False | 1090.95 | 0 |
2928137 | 96520 | None | RGU859 | Concrete works Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete cost does not include excavation A Base Concreting with CC 1:4: 8 For 119.598 Mtr Pole 500x650x150 mm | Each | 286.65 | 286.65 | 2.0 | False | None | None | False | None | False | 573.3 | 0 |
2928138 | 96520 | None | RGU860 | Concrete works Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete cost does not include excavation B Pole concreting CC 1:2:4 without coping For 9 Mtr Pole 650x500x1700 mm | Each | 3315.9 | 3315.9 | 2.0 | False | None | None | False | None | False | 6631.8 | 0 |
2928139 | 96520 | None | RGU861 | Concrete works Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete cost does not include excavation B Pole concreting CC 1:2:4 without coping Guy concreting with Boulders, Mud and SandAs per Drawing No. BESCOMGMCP7 Dt: 24.10.07 | Each | 210.0 | 210.0 | 1.0 | False | None | None | False | None | False | 210.0 | 0 |
2928140 | 96520 | None | RGU862 | C Providing Coping for Poles with CC 1:2:4 As per actuals 150 mm around pole for an height of 300 mm for RCCPSCC Pole | Each | 569.1 | 569.1 | 2.0 | False | None | None | False | None | False | 1138.2 | 0 |
2928141 | 96520 | None | RGU863 | 11 kV, Jointing and Cable Termination Kit as per IS13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x95 Sqmm | Set | 10758.3 | 10758.3 | 1.0 | False | None | None | False | None | False | 10758.3 | 0 |
2928142 | 96520 | None | RGU864 | 11 kV, Jointing and Cable Termination Kit as per IS13573 Heat Shrinkable Type Transition Jointing Kit for XLPE Cable 3x240 Sqmm | Set | 13297.2 | 13297.2 | 2.0 | False | None | None | False | None | False | 26594.4 | 0 |
2928143 | 96520 | None | RGU865 | 11 kV, Jointing and Cable Termination Kit as per IS13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4173.75 | 4173.75 | 6.0 | False | None | None | False | None | False | 25042.5 | 0 |
2928144 | 96520 | None | RGU866 | 11 kV, Jointing and Cable Termination Kit as per IS13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm | Set | 4925.55 | 4925.55 | 1.0 | False | None | None | False | None | False | 4925.55 | 0 |
2928145 | 96520 | None | RGU867 | 11 kV, Jointing and Cable Termination Kit as per IS13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 4270.35 | 4270.35 | 1.0 | False | None | None | False | None | False | 4270.35 | 0 |
2928146 | 96520 | None | RGU868 | 11 kV, Jointing and Cable Termination Kit as per IS13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x240 Sqmm | Set | 5583.9 | 5583.9 | 2.0 | False | None | None | False | None | False | 11167.8 | 0 |
2928147 | 96520 | None | RGU869 | Cable Joint and wiring for HT and LT UG Cable Making and Fixing pot head for HT Cable only Heat shrinkable type HT UG Cable Heat shrinkable Straight Through Joint 3x95 to 3x150 Sqmm | Nos | 2990.4 | 2990.4 | 1.0 | False | None | None | False | None | False | 2990.4 | 0 |
2928148 | 96520 | None | RGU870 | Cable Joint and wiring for HT and LT UG Cable Making and Fixing pot head for HT Cable only Heat shrinkable type HT UG Cable Heat shrinkable Straight Through Joint 3x185 to 3x240 Sqmm | Nos | 2990.4 | 2990.4 | 1.0 | False | None | None | False | None | False | 2990.4 | 0 |
2928149 | 96520 | None | RGU871 | Making and Fixing pot head for HT Cable only Heat shrinkable Type Terminations Indoor and Out door joint kits 3x95 to 3x150 Sqmm | Nos | 2790.9 | 2790.9 | 8.0 | False | None | None | False | None | False | 22327.2 | 0 |
2928150 | 96520 | None | RGU872 | Making and Fixing pot head for HT Cable only Heat shrinkable Type Terminations Indoor and Out door joint kits 3x185 to 3x240 Sqmm | Nos | 2790.9 | 2790.9 | 5.0 | False | None | None | False | None | False | 13954.5 | 0 |
2928151 | 96520 | None | RGU873 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS7098 Part2 Armouring wires dia and Resistivity as per IS3975 95 Sqmm, 54 GI Wires 2.5 mm Dia | Km | 934149.3 | 934149.3 | 0.2 | False | None | None | False | None | False | 186829.86 | 0 |
2928152 | 96520 | None | RGU874 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS7098 Part2 Armouring wires dia and Resistivity as per IS3975 240 Sqmm, 54 GI Wires 2.5 mm Dia | Km | 1738850.4 | 1738850.4 | 0.14 | False | None | None | False | None | False | 243439.056 | 0 |
2928153 | 96520 | None | RGU875 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers as directed by the departmental staff 3x95 to 150 Sqmm | Km | 64388.1 | 64388.1 | 0.14 | False | None | None | False | None | False | 9014.334 | 0 |
2928154 | 96520 | None | RGU876 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers as directed by the departmental staff 3x185 to 3x240 Sqmm | Km | 67360.65 | 67360.65 | 0.1 | False | None | None | False | None | False | 6736.065 | 0 |
2928155 | 96520 | None | RGU877 | Releasing of HT cable after excavation refilling, consolidation Rewinding to the drum etc., | Km | 62407.8 | 62407.8 | 0.18 | False | None | None | False | None | False | 11233.404 | 0 |
2928156 | 96520 | None | RGU878 | do for LT cable | Km | 22428.0 | 22428.0 | 0.01 | False | None | None | False | None | False | 224.28 | 0 |
2928157 | 96520 | None | RGU879 | DAS Specification Compact RMU VCBSF6 Type as per IEC62271 The DAS RMUs shall have the following in addition to the Standards: DC motors, Numerical Relays, Multi functional meters, fault passage indicator FPI , Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers 12V and 24 V , AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connector in the control panel. Suitable space for fixing the Remote Terminal Unit RTU and Radio Modem in Control panel. Suitable Clamps for fixing Antenna Pipe 3 Way RMU 2OD + 1VL One Incomer + One Breakers + One Outgoing 630 Amps with Copper Busbar | Unit | 788249.0 | 788249.0 | 1.0 | False | None | None | False | None | False | 788249.0 | 0 |
2928158 | 96520 | None | RGU880 | Lettering the RMU with enamel paint and also writing single line diagram of each panel, caution Board, Danger Board etc., including cost of Paint, Brush etc., | Per Panel | 1009.05 | 1009.05 | 1.0 | False | None | None | False | None | False | 1009.05 | 0 |
2928159 | 96520 | None | RGU881 | HT and LT Metering Equipment 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT and 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem and 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated as per revised Specification Dwg No. BESCOMGMQS andS Dtd 24.11.2018 | Unit | 255645.6 | 255645.6 | 1.0 | False | None | None | False | None | False | 255645.6 | 0 |
2928160 | 96520 | None | RGU882 | Erection of HT Metering Cubicle, LT Metering Cubicle, LT Feeder Piller Box, LT Distribution Box HT Metering Cubicle, LT Metering Cubicle Erection of HT metering Cubicle on Platform | Nos | 1936.2 | 1936.2 | 1.0 | False | None | None | False | None | False | 1936.2 | 0 |
2928161 | 96520 | None | RGU883 | Supply, erection, testing and commissioning of 800 KVA 5Star rated Copper wound Distribution Transformer 11 KV433Vwith Off Load Tap Switch, Bocholt relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with+ 5percent to 10percent Steps of 2.5percent, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180 Part1 :2014 with all standard accessories as per latest IS standard No:20261977 and IS:335, technical specification and BESCOM approved. With OLTC With RTCC | No | 2492500.0 | 2492500.0 | 1.0 | False | None | None | False | None | False | 2492500.0 | 0 |
2928162 | 96520 | None | RGU884 | HT Panel Protection Realy: Over Load Inst. Realy UV Realy Earth Fault . Out Door Type. Supply, installation, testing and commissioning of outdoor cubicle type 1 Module 11 kV, 50 HZ, AC HT panel. as per BESCOM requirement. The GA drawing shall be got approved by BESCOM authorities before fabrication. The cubicle shall be made out of 14G MS sheet and shall conform to IP 54 category classification. The unit shall be mounted on PCC pedestal. | No | 290000.0 | 290000.0 | 1.0 | False | None | None | False | None | False | 290000.0 | 0 |
2928163 | 96520 | None | RGU885 | Construction of platform 1.5x1.5x1.2 mtr in size stone, for erection of transformersHeavy equipment including all materials, labour.Excavation of 1.5x1.5x1 mt pit for foundation providing and laying cement concrete 1:4:8 for foundation laid in 1cm thick layers, well compacted curing etc., complete providing and construction of stone masonary 0.9m below ground level and 1.2m above ground level neatly hammer dressed in cement morter 1:6 cutting complete providing pointing to stone masonary in cement morter 1:3 after racking joint and nisely lining curing etc., plastering the concrete surfaces in cement morter 1:4 including smooth randering curing etc., curing at every stages completely. | Per Structure | 31879.05 | 31879.05 | 5.0 | False | None | None | False | None | False | 159395.25 | 0 |
2928164 | 96520 | None | RGU886 | Grounding Material Pipe Grounding GI Grounding pipe, B Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg | Nos | 780.15 | 780.15 | 6.0 | False | None | None | False | None | False | 4680.9 | 0 |
2928165 | 96520 | None | RGU887 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | Nos | 709.8 | 709.8 | 6.0 | False | None | None | False | None | False | 4258.8 | 0 |
2928166 | 96520 | None | RGU888 | Good Quality Salt for grounding purposes packed in 50Kg gunny bag | Bag | 325.5 | 325.5 | 6.0 | False | None | None | False | None | False | 1953.0 | 0 |
2928167 | 96520 | None | RGU889 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm allround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Nos | 3685.5 | 3685.5 | 2.0 | False | None | None | False | None | False | 7371.0 | 0 |
2928168 | 96520 | None | RGU890 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm allround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Nos | 4468.8 | 4468.8 | 2.0 | False | None | None | False | None | False | 8937.6 | 0 |
2928169 | 96520 | None | RGU891 | Rod Earthing Rod type of earthing using 40 mm Dia, 3 Mtr long MSrod as ground rod, in earth pit of 300 mm width and3300 mm depth and using 50x6 mm flat welded to ground rod as terminal and connected to equipment ground terminal using PVC Al wire as specified | Nos | 2280.6 | 2280.6 | 2.0 | False | None | None | False | None | False | 4561.2 | 0 |
2928170 | 96520 | None | RGU892 | Bentonite clay slurry for earthing in 50 Kg Bag | Bag | 386.4 | 386.4 | 2.0 | False | None | None | False | None | False | 772.8 | 0 |
2928171 | 96520 | None | RGU893 | Alkathine tube Transparent Alkathine tube 19 mm dia, 2 mm thick in coils of 30 Mtr | Coil | 542.85 | 542.85 | 5.0 | False | None | None | False | None | False | 2714.25 | 0 |
2928172 | 96520 | None | RGU894 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | Per Pit | 796.95 | 796.95 | 8.0 | False | None | None | False | None | False | 6375.6 | 0 |
2928173 | 96520 | None | RGU895 | Digging of Pit for providing GI Pipe type Earthing Hard Soil | Per Pit | 3139.5 | 3139.5 | 4.0 | False | None | None | False | None | False | 12558.0 | 0 |
2928174 | 96520 | None | RGU896 | Miscellaneous Matarials Cable Covering Tile 125x250x40 mm | Per Thousand | 10767.75 | 10767.75 | 0.2 | False | None | None | False | None | False | 2153.55 | 0 |
2928175 | 96520 | None | RGU897 | Miscellaneous Matarials Cable Covering Tile 125x125x40 mm | Per Thousand | 5383.35 | 5383.35 | 0.2 | False | None | None | False | None | False | 1076.67 | 0 |
2928176 | 96520 | None | RGU898 | Miscellaneous Matarials RCC Hume Pipe 2000 mm long 150 mm Dia | Nos | 322.35 | 322.35 | 10.0 | False | None | None | False | None | False | 3223.5 | 0 |
2928177 | 96520 | None | RGU899 | Miscellaneous Matarials RCC Hume Pipe 2000 mm long 200 mm Dia | Nos | 409.5 | 409.5 | 20.0 | False | None | None | False | None | False | 8190.0 | 0 |
2928178 | 96520 | None | RGU900 | Miscellaneous Matarials Collars for RCC Hume Pipe 150 mm Dia | Nos | 86.1 | 86.1 | 6.0 | False | None | None | False | None | False | 516.6 | 0 |
2928179 | 96520 | None | RGU901 | Miscellaneous Matarials Collars for RCC Hume Pipe 200 mm Dia | Nos | 108.15 | 108.15 | 11.0 | False | None | None | False | None | False | 1189.65 | 0 |
2928180 | 96520 | None | RGU902 | Miscellaneous Matarials Route and Joint indicating slab with MS Anchor rod | Nos | 139.65 | 139.65 | 25.0 | False | None | None | False | None | False | 3491.25 | 0 |
2928181 | 96520 | None | RGU903 | Miscellaneous Matarials Black Cambric tape 25 mm wide 10 mil thick and in rolls of 50 Mtr | Roll | 137.55 | 137.55 | 10.0 | False | None | None | False | None | False | 1375.5 | 0 |
2928182 | 96520 | None | RGU904 | Miscellaneous Matarials Yellow Cambric tape 25 mm wide 7 mil thick and in rolls of 50 Mtr | Roll | 126.0 | 126.0 | 10.0 | False | None | None | False | None | False | 1260.0 | 0 |
2928183 | 96520 | None | RGU905 | Miscellaneous Matarials Spiral Earth Electrode | Set | 358.05 | 358.05 | 2.0 | False | None | None | False | None | False | 716.1 | 0 |
2928184 | 96520 | None | RGU906 | Miscellaneous Matarials CautionDanger Board | Nos | 157.5 | 157.5 | 2.0 | False | None | None | False | None | False | 315.0 | 0 |
2928185 | 96520 | None | RGU907 | 25x6mm GI strip Fencing,RMU,HT Breacker and LTK | Mtr | 134.4 | 134.4 | 103.0 | False | None | None | False | None | False | 13843.2 | 0 |
2928186 | 96520 | None | RGU908 | 40x6mm GI strip Tr. Body | Mtr | 190.05 | 190.05 | 35.0 | False | None | None | False | None | False | 6651.75 | 0 |
2928187 | 96520 | None | RGU909 | 600x600x3mm GI Plate Body earthing | Each | 918.75 | 918.75 | 6.0 | False | None | None | False | None | False | 5512.5 | 0 |
2928188 | 96520 | None | RGU910 | 25x3mm Copper strip Tr. Neutral | Mtr | 598.5 | 598.5 | 60.0 | False | None | None | False | None | False | 35910.0 | 0 |
2928189 | 96520 | None | RGU911 | 600x600x3mm Copper plate Tr.Neutral | Each | 7792.05 | 7792.05 | 3.0 | False | None | None | False | None | False | 23376.15 | 0 |
2928190 | 96520 | None | RGU912 | Chain Link FencingSupplying and fixing M.S rectangular pole made of 2 equal angles 65 x 65 x 6 mm welded together and fixed in C.C 1:2:4 with 2 nos 16 mm dia MS welded fost rods equal of length 25 mm including cost of all materials cutting, bending, scarffolding where ever necessary, nicely finishing the welded joints with all lead and lift as per the direction of the engineer incharge of the work and including, provoiding 2 coats of approved quality paint over 1 coat of shop painting excluding cost of earth work and concreate . | Rmtr | 1350.0 | 1350.0 | 55.0 | False | None | None | False | None | False | 74250.0 | 0 |
2928191 | 96520 | None | RGU913 | Providing Chain link fencing 50 mm size of 8 gauage properly streched between rectangular poles and fixed with sutable bolt and nuts, the free ends shall be welded to the pole and black pipe at top and bottom as required including cost of all materials, labour, | Sqmm | 850.0 | 850.0 | 55.0 | False | None | None | False | None | False | 46750.0 | 0 |
2928192 | 96520 | None | RGU914 | Supply Intstallation and Spreading of 40mm thick metal, 80mm depth in outdoor H.T yard | Sqm | 700.0 | 700.0 | 35.0 | False | None | None | False | None | False | 24500.0 | 0 |
2928193 | 96520 | None | RGU915 | Supplying of two bucket stand alongwith buckets. Complete | Each | 630.0 | 630.0 | 4.0 | False | None | None | False | None | False | 2520.0 | 0 |
2928194 | 96520 | None | RGU916 | Rubber Hand Gloves 15 kV,SEAMLESS Confirming to IS | Pair | 170.0 | 170.0 | 4.0 | False | None | None | False | None | False | 680.0 | 0 |
2928195 | 96520 | None | RGU917 | Supplying of first aid box. Complete | Each | 600.0 | 600.0 | 4.0 | False | None | None | False | None | False | 2400.0 | 0 |
2928196 | 96520 | None | RGU918 | Supplying of SAFETY MASK. Complete | Each | 64.0 | 64.0 | 10.0 | False | None | None | False | None | False | 640.0 | 0 |
2928197 | 96520 | None | RGU919 | Supplying of FIRST AID CHART with lamination. Complete | Each | 225.0 | 225.0 | 4.0 | False | None | None | False | None | False | 900.0 | 0 |
2928198 | 96520 | None | RGU920 | Supply, erection, testing, commissioning including actual measurement at site of TPN bus duct of Al. conductor enclosed in 2 mm thick painted CRCA sheet and shall be accessible from top and bottom. It should be complete with required steel stracture supports, bends etc complete in everyway. It shall be suitable for fault level of 50 KA and distance between SMC supports shall not exceed 350mm. It shall have louvres at regular intervals for following ratings along with two distinct earth bars. The bus bar temp shall not be more than 85 deg C and body temperature shall not exceed 60 deg. C Two distinct and separate earth bus shall run outside along the duct. Length shall be measured along centre line of bus duct and this bus duct will be partly indoor and partly outdoor. We shall not use 6mm thick busduct and there shall be no humming sound in bus duct. Measurement of Bus duct shall be along the centre phase of Bus duct from end to end. Air Insulated . 1250 Amps net after derating TPN Bus duct IP 52 Indoor type shall be suitable 50KA fault level. The exact calculations of bus duct shall be submitted and minimum derating of 0.75 shall be considered. From existing LT panel 1 to Main LT panel2 Flexible end laminated copper terminations Outdoor type for 1250 amps TPN Aluminium Bus Duct. braided wire shall be used Note : Including installation. | Mtr | 41500.0 | 41500.0 | 4.0 | False | None | None | False | None | False | 166000.0 | 0 |
2928199 | 96520 | None | RGU921 | Fabricating supplying and mounting MS box made out....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.53 | 0.53 | 75042.0 | False | None | None | False | None | False | 39772.26 | 0 |
2928200 | 96520 | None | RGU922 | Fabricating supplying and mounting MS box made out....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG | Sq CM | 0.45 | 0.45 | 162832.0 | False | None | None | False | None | False | 73274.4 | 0 |
2928201 | 96520 | None | RGU923 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolicFRPDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4x50x10 mm Aluminium Strips | Mtr | 4667.25 | 4667.25 | 7.0 | False | None | None | False | None | False | 32670.75 | 0 |
2928202 | 96520 | None | RGU924 | Supplying and fixing angle iron frame work fabricated out ofM.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mm | Mtr | 582.75 | 582.75 | 4.0 | False | None | None | False | None | False | 2331.0 | 0 |
2928203 | 96520 | None | RGU925 | LTK Incomer 1x1250A 4P EDO ACB from 1x 800 KVA Transformer and this will also be connected to LT Kiosk through busduct. Separate busduct will be made. Supplying and fixing of One no. incomer of 1 x 1250A 4P EDO ACB with microprocessor based over current, short circuit and earth fault release. ACB releases shall have over current different time settings, short ckt. release with variable setting, short time delay, instantaneous current setting, earth fault release, earth fault time delay. Suitable links shall be provided for 1250A after derating Aluminium Busduct termination. Air Insulated . 1250 A 50 KA | Each | 195750.0 | 195750.0 | 1.0 | False | None | None | False | None | False | 195750.0 | 0 |
2928204 | 96520 | None | RGU926 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5063 A TPN For TVSS Connectivity | Each | 3242.4 | 3242.4 | 1.0 | False | None | None | False | None | False | 3242.4 | 0 |
2928205 | 96520 | None | RGU927 | Surge Protection device SPD 3 phase TypeB | Each | 13500.0 | 13500.0 | 1.0 | False | None | None | False | None | False | 13500.0 | 0 |
2928206 | 96520 | None | RGU928 | Supplying, fixing and wiring earth leakage relay with corebalanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delayauto manual reset facility suitable to mount on DIN rail flush mounting on panel board. | Each | 9717.75 | 9717.75 | 3.0 | False | None | None | False | None | False | 29153.25 | 0 |
2928207 | 96520 | None | RGU929 | Supplying, fixing and wiring 10005A to 16005A 15VA Burden class 1 Current Transformer | Each | 840.0 | 840.0 | 4.0 | False | None | None | False | None | False | 3360.0 | 0 |
2928208 | 96520 | None | RGU930 | 250 kVA DIESEL GENERATOR SET Supplying, installing, testing and commissioning of DieselGenerator set with following specifications. Power rating as perstandard reference condition as perBS 5514ISO 3046 ISO8528 and IS 1002ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM andconform to ISO 8528 specifications. The engines are radiatorcooled, four stroke and multi cylinder, conforming to ISO3046. The scope of supply includes: Electrical starter motor12VDC Battery charging alternator, Bosch fuel system withmechanical governor, A1 Class. Spinon lube oil filter, Spinondual fuel filter with water separator, Turbocharger, Charge aircooler, Silencer Hospital grade , Dry type air cleaner,Shutoff coil, Flywheel and flywheel housing, First fill of lubeoil and coolant, Safety for low lube oil pressure, Safety for highwater temperature, Permissible overload of 10percent for one hourin 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM padsControl Panel: The control panel is manufactured with 1416gauge CRCA sheet and is powder coated for weatherproof andlong lasting finish. The control panel consists of the followingparts: PS0500 Controller, Aluminium bus bars withsuitable capacity withinoutgoing terminals, Indicating lA for'Load On' and 'Set Running', Instrument fuses duly wiredand ferruled, MCCB of suitable rating with overload andshort circuit protections. Use of special hardware for longer life, Insulation materialmeets exacting IS 8183 specifications for better soundattenuation, Flush styling no projections, Fluid drains for lubeoil and fuel, Fuel filling point inside the enclosure. The completeset shall have sufficient safety and adhere to NEC, NBC 2016,IEC, CPWD specifications, PCB norms and KSGEI Acts andRules. | Set | 1999537.05 | 1999537.05 | 1.0 | False | None | None | False | None | False | 1999537.05 | 0 |
2928209 | 96520 | None | RGU931 | Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type basefloor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal OL relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine startstoplogic, Mainsgenerator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperatureLube oil pressureengine speed, VoltageampereFrequency kVA, Runninghour count, Noof starts, Fault indication, over under speed, Fails to start, Low oil pleasure, High engine temperature, Underover voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt AutoManual and FlatBoost facility. The complete set shall havesufficient safety and adhere to NEC, NBC 2016, IEC, CPWDspecifications, PCB norms and KSGEI Acts and Rules. 250 kVA | Each | 295100.4 | 295100.4 | 1.0 | False | None | None | False | None | False | 295100.4 | 0 |
2928210 | 96520 | None | RGU932 | Supply and installation of Exhaust piping using 125MM dia of M.S. as per IS including hardwares like flanges, bends, bolts and Gaskets etc, for Connection of Exhaust Piping from DG set complete with supporting Structures and Foundation etc complete. The same shall conform to CPCB norms. | Mtr | 2550.0 | 2550.0 | 30.0 | False | None | None | False | None | False | 76500.0 | 0 |
2928211 | 96520 | None | RGU933 | Supply and fixing of MS angle channel with anchor fasteners for supporting of exhaust fuel piping with epoxy painting | Kgs | 135.0 | 135.0 | 250.0 | False | None | None | False | None | False | 33750.0 | 0 |
2928212 | 96520 | None | RGU934 | Providing thermal cladding for 120 exhaust pipe by mineral wool wrapping with chicken mesh and Alu. sheet including bends. | Mtr | 1250.0 | 1250.0 | 30.0 | False | None | None | False | None | False | 37500.0 | 0 |
2928213 | 96520 | None | RGU935 | Supplying and drawing Flexible Multicore Cable manufacturedwith electrolytic grade flexible copper with low conductorconfirming to IS 81301984 and Virgin PVC insulationsheathed suitable for working voltage upto 1100V as per IS694:1990A2XFY 4C X 2.5Sq.mm | Mtr | 78.75 | 78.75 | 35.0 | False | None | None | False | None | False | 2756.25 | 0 |
2928214 | 96520 | None | RGU936 | Supplying and drawing Flexible Multicore Cable manufacturedwith electrolytic grade flexible copper with low conductorconfirming to IS 81301984 and Virgin PVC insulationsheathed suitable for working voltage upto 1100V as per IS694:1990A2XFY4C X 4Sq.mm | Mtr | 68.25 | 68.25 | 40.0 | False | None | None | False | None | False | 2730.0 | 0 |
2928215 | 96520 | None | RGU937 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathedXLPE aluminium conductor cable of 1.1 KV Grade as required. 4X10 Sq. mm 25 mm | Each | 282.45 | 282.45 | 4.0 | False | None | None | False | None | False | 1129.8 | 0 |
2928216 | 96520 | None | RGU938 | Approval charges from Electrical inspectorate | LS | 135000.0 | 135000.0 | 1.0 | False | None | None | False | None | False | 135000.0 | 0 |
2928217 | 96520 | None | RGU939 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm allround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 4468.8 | 4468.8 | 4.0 | False | None | None | False | None | False | 17875.2 | 0 |
2928218 | 96520 | None | RGU940 | Using 4ft. Copper bonded rod with backfill compound | Kit | 4754.4 | 4754.4 | 1.0 | False | None | None | False | None | False | 4754.4 | 0 |
2928219 | 96520 | None | RGU941 | Using 10ft. Copper bonded rod with backfill compound | Kit | 8918.7 | 8918.7 | 1.0 | False | None | None | False | None | False | 8918.7 | 0 |
2928220 | 96520 | None | RGU942 | 25x3mm GI strip In Cable Trays and All Electrical Equipments. | Mtr | 86.1 | 86.1 | 40.0 | False | None | None | False | None | False | 3444.0 | 0 |
2928221 | 96520 | None | RGU943 | 600x600x3mm GI Plate | Each | 918.75 | 918.75 | 2.0 | False | None | None | False | None | False | 1837.5 | 0 |
2928222 | 96520 | None | RGU944 | 25x3mm Copper strip | Mtr | 598.5 | 598.5 | 55.0 | False | None | None | False | None | False | 32917.5 | 0 |
2928223 | 96520 | None | RGU945 | 600x600x3mm Copper plate | Each | 7792.05 | 7792.05 | 2.0 | False | None | None | False | None | False | 15584.1 | 0 |
2928224 | 96520 | None | RGU946 | MV CABLE LAYING Laying of one number PVC insulated and PVC sheathedXLPE power cable of 1.1 KV grade of following size direct in ground including excavation,snd cushioning,protective covering and refilling the trench etc as required. 1000 X 450 X 750 mm LxWxD Above 95 sq.mm and upto 185 sq, mm | Mtr | 79.8 | 79.8 | 60.0 | False | None | None | False | None | False | 4788.0 | 0 |
2928225 | 96520 | None | RGU947 | GI Pipe B Class as per IS1239 GI Pipe 100 mm Dia | Mtr | 1359.75 | 1359.75 | 10.0 | False | None | None | False | None | False | 13597.5 | 0 |
2928226 | 96520 | None | RGU948 | Sanitary and CP fixtures Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever , conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5079.9 | 5079.9 | 11.0 | False | None | None | False | None | False | 55878.9 | 0 |
2928227 | 96520 | None | RGU949 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 880.95 | 880.95 | 11.0 | False | None | None | False | None | False | 9690.45 | 0 |
2928228 | 96520 | None | RGU950 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3559.5 | 3559.5 | 10.0 | False | None | None | False | None | False | 35595.0 | 0 |
2928229 | 96520 | None | RGU951 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 321.3 | 321.3 | 11.0 | False | None | None | False | None | False | 3534.3 | 0 |
2928230 | 96520 | None | RGU952 | C.P. Brass stop cock concealed 15 mm GF Toilet | Each | 551.25 | 551.25 | 11.0 | False | None | None | False | None | False | 6063.75 | 0 |
2928231 | 96520 | None | RGU953 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. | Nos | 96.6 | 96.6 | 11.0 | False | None | None | False | None | False | 1062.6 | 0 |
2928232 | 96520 | None | RGU954 | Providing and fixing unplasticised PVC connection pipe with brassunions : 15 mm nominal bore | Nos | 110.25 | 110.25 | 11.0 | False | None | None | False | None | False | 1212.75 | 0 |
2928233 | 96520 | None | RGU955 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 492.45 | 492.45 | 11.0 | False | None | None | False | None | False | 5416.95 | 0 |
2928234 | 96520 | None | RGU956 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1281.0 | 1281.0 | 10.0 | False | None | None | False | None | False | 12810.0 | 0 |
2928235 | 96520 | None | RGU957 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | Nos | 152.25 | 152.25 | 11.0 | False | None | None | False | None | False | 1674.75 | 0 |
2928236 | 96520 | None | RGU958 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern | Nos | 13723.5 | 13723.5 | 4.0 | False | None | None | False | None | False | 54894.0 | 0 |
2928237 | 96520 | None | RGU959 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 300.3 | 300.3 | 3.0 | False | None | None | False | None | False | 900.9 | 0 |
2928238 | 96520 | None | RGU960 | Providing and fixing Sink cock with swivel spout and wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 5898.9 | 5898.9 | 1.0 | False | None | None | False | None | False | 5898.9 | 0 |
2928239 | 96520 | None | RGU961 | Providing and fixing Stainless Steel A ISI 304 188 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : | Nos | 3030.3 | 3030.3 | 1.0 | False | None | None | False | None | False | 3030.3 | 0 |
2928240 | 96520 | None | RGU962 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 575.4 | 575.4 | 11.0 | False | None | None | False | None | False | 6329.4 | 0 |
2928241 | 96520 | None | RGU963 | Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessories complete | Nos | 256.2 | 256.2 | 19.0 | False | None | None | False | None | False | 4867.8 | 0 |
2928242 | 96520 | None | RGU964 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 8566.95 | 8566.95 | 1.0 | False | None | None | False | None | False | 8566.95 | 0 |
2928243 | 96520 | None | RGU965 | Sanitary piping Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: 50mm nominal bore pipes, From Wash basin, Sink and Urinal line | Mtr | 210.0 | 210.0 | 37.0 | False | None | None | False | None | False | 7770.0 | 0 |
2928244 | 96520 | None | RGU966 | Sanitary piping Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 512.4 | 512.4 | 75.0 | False | None | None | False | None | False | 38430.0 | 0 |
2928245 | 96520 | None | RGU967 | Sanitary piping Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc. for: PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 995.4 | 995.4 | 70.0 | False | None | None | False | None | False | 69678.0 | 0 |
2928246 | 96520 | None | RGU968 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 50mm | Mtr | 42.0 | 42.0 | 37.0 | False | None | None | False | None | False | 1554.0 | 0 |
2928247 | 96520 | None | RGU969 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm | Mtr | 79.8 | 79.8 | 75.0 | False | None | None | False | None | False | 5985.0 | 0 |
2928248 | 96520 | None | RGU970 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm | Mtr | 117.6 | 117.6 | 70.0 | False | None | None | False | None | False | 8232.0 | 0 |
2928249 | 96520 | None | RGU971 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | Mtr | 397.95 | 397.95 | 85.0 | False | None | None | False | None | False | 33825.75 | 0 |
2928250 | 96520 | None | RGU972 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes | Mtr | 500.85 | 500.85 | 55.0 | False | None | None | False | None | False | 27546.75 | 0 |
2928251 | 96520 | None | RGU973 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal dia Pipes | Mtr | 584.85 | 584.85 | 6.0 | False | None | None | False | None | False | 3509.1 | 0 |
2928252 | 96520 | None | RGU974 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM Copper alloy Gate valves | Nos | 932.4 | 932.4 | 2.0 | False | None | None | False | None | False | 1864.8 | 0 |
2928253 | 96520 | None | RGU975 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1227.45 | 1227.45 | 3.0 | False | None | None | False | None | False | 3682.35 | 0 |
2928254 | 96520 | None | RGU976 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1404.9 | 1404.9 | 2.0 | False | None | None | False | None | False | 2809.8 | 0 |
2928255 | 96520 | None | RGU977 | Sanitary and CP fixtures Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever , conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5130.7 | 5130.7 | 10.0 | False | None | None | False | None | False | 51307.0 | 0 |
2928256 | 96520 | None | RGU978 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 889.76 | 889.76 | 10.0 | False | None | None | False | None | False | 8897.6 | 0 |
2928257 | 96520 | None | RGU979 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3268.46 | 3268.46 | 9.0 | False | None | None | False | None | False | 29416.14 | 0 |
2928258 | 96520 | None | RGU980 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 324.51 | 324.51 | 9.0 | False | None | None | False | None | False | 2920.59 | 0 |
2928259 | 96520 | None | RGU981 | C.P. Brass stop cock concealed 15 mm | Nos | 556.76 | 556.76 | 9.0 | False | None | None | False | None | False | 5010.84 | 0 |
2928260 | 96520 | None | RGU982 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. | Nos | 93.32 | 93.32 | 9.0 | False | None | None | False | None | False | 839.88 | 0 |
2928261 | 96520 | None | RGU983 | Providing and fixing unplasticised PVC connection pipe with brassunions : 15 mm nominal bore | Nos | 96.51 | 96.51 | 9.0 | False | None | None | False | None | False | 868.59 | 0 |
2928262 | 96520 | None | RGU984 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 526.01 | 526.01 | 9.0 | False | None | None | False | None | False | 4734.09 | 0 |
2928263 | 96520 | None | RGU985 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1293.81 | 1293.81 | 9.0 | False | None | None | False | None | False | 11644.29 | 0 |
2928264 | 96520 | None | RGU986 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | Nos | 153.77 | 153.77 | 9.0 | False | None | None | False | None | False | 1383.93 | 0 |
2928265 | 96520 | None | RGU987 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern | Nos | 13860.74 | 13860.74 | 4.0 | False | None | None | False | None | False | 55442.96 | 0 |
2928266 | 96520 | None | RGU988 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 303.3 | 303.3 | 2.0 | False | None | None | False | None | False | 606.6 | 0 |
2928267 | 96520 | None | RGU989 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 581.15 | 581.15 | 10.0 | False | None | None | False | None | False | 5811.5 | 0 |
2928268 | 96520 | None | RGU990 | Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessories complete | Nos | 258.76 | 258.76 | 17.0 | False | None | None | False | None | False | 4398.92 | 0 |
2928269 | 96520 | None | RGU991 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 8652.62 | 8652.62 | 1.0 | False | None | None | False | None | False | 8652.62 | 0 |
2928270 | 96520 | None | RGU992 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 50mm nominal bore pipes, From, Wash basin, Sink and Urinal lines | Mtr | 212.1 | 212.1 | 35.0 | False | None | None | False | None | False | 7423.5 | 0 |
2928271 | 96520 | None | RGU993 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 517.52 | 517.52 | 55.0 | False | None | None | False | None | False | 28463.6 | 0 |
2928272 | 96520 | None | RGU994 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 1005.35 | 1005.35 | 65.0 | False | None | None | False | None | False | 65347.75 | 0 |
2928273 | 96520 | None | RGU995 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 50mm | Mtr | 42.42 | 42.42 | 40.0 | False | None | None | False | None | False | 1696.8 | 0 |
2928274 | 96520 | None | RGU996 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm | Mtr | 80.6 | 80.6 | 55.0 | False | None | None | False | None | False | 4433.0 | 0 |
2928275 | 96520 | None | RGU997 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm | Mtr | 118.78 | 118.78 | 65.0 | False | None | None | False | None | False | 7720.7 | 0 |
2928276 | 96520 | None | RGU998 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | Mtr | 395.57 | 395.57 | 55.0 | False | None | None | False | None | False | 21756.35 | 0 |
2928277 | 96520 | None | RGU999 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes | Mtr | 504.8 | 504.8 | 55.0 | False | None | None | False | None | False | 27764.0 | 0 |
2928278 | 96520 | None | RGU1000 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal dia Pipes | Mtr | 589.64 | 589.64 | 6.0 | False | None | None | False | None | False | 3537.84 | 0 |
2928279 | 96520 | None | RGU1001 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1239.72 | 1239.72 | 2.0 | False | None | None | False | None | False | 2479.44 | 0 |
2928280 | 96520 | None | RGU1002 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1418.95 | 1418.95 | 2.0 | False | None | None | False | None | False | 2837.9 | 0 |
2928281 | 96520 | None | RGU1003 | Sanitary and CP fixtures Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever , conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5181.5 | 5181.5 | 12.0 | False | None | None | False | None | False | 62178.0 | 0 |
2928282 | 96520 | None | RGU1004 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 898.57 | 898.57 | 12.0 | False | None | None | False | None | False | 10782.84 | 0 |
2928283 | 96520 | None | RGU1005 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3300.82 | 3300.82 | 15.0 | False | None | None | False | None | False | 49512.3 | 0 |
2928284 | 96520 | None | RGU1006 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 327.73 | 327.73 | 48.0 | False | None | None | False | None | False | 15731.04 | 0 |
2928285 | 96520 | None | RGU1007 | C.P. Brass stop cock concealed 15 mm | Nos | 562.28 | 562.28 | 48.0 | False | None | None | False | None | False | 26989.44 | 0 |
2928286 | 96520 | None | RGU1008 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. | Nos | 94.25 | 94.25 | 48.0 | False | None | None | False | None | False | 4524.0 | 0 |
2928287 | 96520 | None | RGU1009 | Providing and fixing unplasticised PVC connection pipe with brassunions : 15 mm nominal bore | Nos | 97.46 | 97.46 | 48.0 | False | None | None | False | None | False | 4678.08 | 0 |
2928288 | 96520 | None | RGU1010 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 531.22 | 531.22 | 48.0 | False | None | None | False | None | False | 25498.56 | 0 |
2928289 | 96520 | None | RGU1011 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1306.62 | 1306.62 | 15.0 | False | None | None | False | None | False | 19599.3 | 0 |
2928290 | 96520 | None | RGU1012 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | Nos | 155.3 | 155.3 | 48.0 | False | None | None | False | None | False | 7454.4 | 0 |
2928291 | 96520 | None | RGU1013 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern | Nos | 13997.97 | 13997.97 | 4.0 | False | None | None | False | None | False | 55991.88 | 0 |
2928292 | 96520 | None | RGU1014 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 306.31 | 306.31 | 2.0 | False | None | None | False | None | False | 612.62 | 0 |
2928293 | 96520 | None | RGU1015 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm | Nos | 5442.82 | 5442.82 | 32.0 | False | None | None | False | None | False | 174170.24 | 0 |
2928294 | 96520 | None | RGU1016 | Providing and fixing Stainless Steel A ISI 304 188 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm | Nos | 6016.88 | 6016.88 | 1.0 | False | None | None | False | None | False | 6016.88 | 0 |
2928295 | 96520 | None | RGU1017 | Providing and fixing Sink cock with swivel spout and wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 3090.91 | 3090.91 | 33.0 | False | None | None | False | None | False | 102000.03 | 0 |
2928296 | 96520 | None | RGU1018 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 586.91 | 586.91 | 12.0 | False | None | None | False | None | False | 7042.92 | 0 |
2928297 | 96520 | None | RGU1019 | Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessories complete | Nos | 261.32 | 261.32 | 56.0 | False | None | None | False | None | False | 14633.92 | 0 |
2928298 | 96520 | None | RGU1020 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 8738.29 | 8738.29 | 1.0 | False | None | None | False | None | False | 8738.29 | 0 |
2928299 | 96520 | None | RGU1021 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete 50mm nominal bore pipes, From Wash Basin, Sink and Urinal lines | Mtr | 214.2 | 214.2 | 125.0 | False | None | None | False | None | False | 26775.0 | 0 |
2928300 | 96520 | None | RGU1022 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 522.65 | 522.65 | 250.0 | False | None | None | False | None | False | 130662.5 | 0 |
2928301 | 96520 | None | RGU1023 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 1015.31 | 1015.31 | 95.0 | False | None | None | False | None | False | 96454.45 | 0 |
2928302 | 96520 | None | RGU1024 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 50mm | Mtr | 42.84 | 42.84 | 125.0 | False | None | None | False | None | False | 5355.0 | 0 |
2928303 | 96520 | None | RGU1025 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm | Mtr | 81.4 | 81.4 | 250.0 | False | None | None | False | None | False | 20350.0 | 0 |
2928304 | 96520 | None | RGU1026 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm | Mtr | 119.95 | 119.95 | 95.0 | False | None | None | False | None | False | 11395.25 | 0 |
2928305 | 96520 | None | RGU1027 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | Mtr | 399.48 | 399.48 | 195.0 | False | None | None | False | None | False | 77898.6 | 0 |
2928306 | 96520 | None | RGU1028 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes | Mtr | 509.8 | 509.8 | 110.0 | False | None | None | False | None | False | 56078.0 | 0 |
2928307 | 96520 | None | RGU1029 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM Copper alloy Gate valves | Nos | 951.05 | 951.05 | 3.0 | False | None | None | False | None | False | 2853.15 | 0 |
2928308 | 96520 | None | RGU1030 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1252.0 | 1252.0 | 8.0 | False | None | None | False | None | False | 10016.0 | 0 |
2928309 | 96520 | None | RGU1031 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1433.0 | 1433.0 | 2.0 | False | None | None | False | None | False | 2866.0 | 0 |
2928310 | 96520 | None | RGU1032 | Sanitary and CP fixtures Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually con trolled device handle lever , conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5232.3 | 5232.3 | 12.0 | False | None | None | False | None | False | 62787.6 | 0 |
2928311 | 96520 | None | RGU1033 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 907.38 | 907.38 | 12.0 | False | None | None | False | None | False | 10888.56 | 0 |
2928312 | 96520 | None | RGU1034 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3333.18 | 3333.18 | 21.0 | False | None | None | False | None | False | 69996.78 | 0 |
2928313 | 96520 | None | RGU1035 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 330.94 | 330.94 | 30.0 | False | None | None | False | None | False | 9928.2 | 0 |
2928314 | 96520 | None | RGU1036 | C.P. Brass stop cock concealed 15 mm | Each | 567.79 | 567.79 | 30.0 | False | None | None | False | None | False | 17033.7 | 0 |
2928315 | 96520 | None | RGU1037 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. | Nos | 95.17 | 95.17 | 30.0 | False | None | None | False | None | False | 2855.1 | 0 |
2928316 | 96520 | None | RGU1038 | Providing and fixing unplasticised PVC connection pipe with brassunions : 15 mm nominal bore | Nos | 98.42 | 98.42 | 30.0 | False | None | None | False | None | False | 2952.6 | 0 |
2928317 | 96520 | None | RGU1039 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 536.42 | 536.42 | 30.0 | False | None | None | False | None | False | 16092.6 | 0 |
2928318 | 96520 | None | RGU1040 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1319.43 | 1319.43 | 21.0 | False | None | None | False | None | False | 27708.03 | 0 |
2928319 | 96520 | None | RGU1041 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | Nos | 156.82 | 156.82 | 30.0 | False | None | None | False | None | False | 4704.6 | 0 |
2928320 | 96520 | None | RGU1042 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern | Nos | 14135.21 | 14135.21 | 4.0 | False | None | None | False | None | False | 56540.84 | 0 |
2928321 | 96520 | None | RGU1043 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 309.31 | 309.31 | 2.0 | False | None | None | False | None | False | 618.62 | 0 |
2928322 | 96520 | None | RGU1044 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm | Nos | 5496.18 | 5496.18 | 8.0 | False | None | None | False | None | False | 43969.44 | 0 |
2928323 | 96520 | None | RGU1045 | Providing and fixing Stainless Steel A ISI 304 188 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Nos | 6075.87 | 6075.87 | 1.0 | False | None | None | False | None | False | 6075.87 | 0 |
2928324 | 96520 | None | RGU1046 | Providing and fixing Sink cock with swivel spout and wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 3090.91 | 3090.91 | 9.0 | False | None | None | False | None | False | 27818.19 | 0 |
2928325 | 96520 | None | RGU1047 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 592.66 | 592.66 | 12.0 | False | None | None | False | None | False | 7111.92 | 0 |
2928326 | 96520 | None | RGU1048 | Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessories complete | Nos | 263.89 | 263.89 | 35.0 | False | None | None | False | None | False | 9236.15 | 0 |
2928327 | 96520 | None | RGU1049 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 8823.96 | 8823.96 | 1.0 | False | None | None | False | None | False | 8823.96 | 0 |
2928328 | 96520 | None | RGU1050 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 50mm nominal bore pipes, From Sink and Urinal lines | Mtr | 216.3 | 216.3 | 85.0 | False | None | None | False | None | False | 18385.5 | 0 |
2928329 | 96520 | None | RGU1051 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 527.77 | 527.77 | 205.0 | False | None | None | False | None | False | 108192.85 | 0 |
2928330 | 96520 | None | RGU1052 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 1025.26 | 1025.26 | 85.0 | False | None | None | False | None | False | 87147.1 | 0 |
2928331 | 96520 | None | RGU1053 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 50mm | Mtr | 43.26 | 43.26 | 85.0 | False | None | None | False | None | False | 3677.1 | 0 |
2928332 | 96520 | None | RGU1054 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm | Mtr | 82.19 | 82.19 | 205.0 | False | None | None | False | None | False | 16848.95 | 0 |
2928333 | 96520 | None | RGU1055 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm | Mtr | 121.13 | 121.13 | 85.0 | False | None | None | False | None | False | 10296.05 | 0 |
2928334 | 96520 | None | RGU1056 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | Mtr | 403.4 | 403.4 | 195.0 | False | None | None | False | None | False | 78663.0 | 0 |
2928335 | 96520 | None | RGU1057 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes | Mtr | 514.79 | 514.79 | 70.0 | False | None | None | False | None | False | 36035.3 | 0 |
2928336 | 96520 | None | RGU1058 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal dia Pipes | Mtr | 601.31 | 601.31 | 6.0 | False | None | None | False | None | False | 3607.86 | 0 |
2928337 | 96520 | None | RGU1059 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM Copper alloy Gate valves | Nos | 960.37 | 960.37 | 6.0 | False | None | None | False | None | False | 5762.22 | 0 |
2928338 | 96520 | None | RGU1060 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1264.27 | 1264.27 | 4.0 | False | None | None | False | None | False | 5057.08 | 0 |
2928339 | 96520 | None | RGU1061 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1447.05 | 1447.05 | 2.0 | False | None | None | False | None | False | 2894.1 | 0 |
2928340 | 96520 | None | RGU1062 | Sanitary and CP fixtures Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever , conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5283.1 | 5283.1 | 12.0 | False | None | None | False | None | False | 63397.2 | 0 |
2928341 | 96520 | None | RGU1063 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 916.19 | 916.19 | 12.0 | False | None | None | False | None | False | 10994.28 | 0 |
2928342 | 96520 | None | RGU1064 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3365.54 | 3365.54 | 23.0 | False | None | None | False | None | False | 77407.42 | 0 |
2928343 | 96520 | None | RGU1065 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 334.15 | 334.15 | 24.0 | False | None | None | False | None | False | 8019.6 | 0 |
2928344 | 96520 | None | RGU1066 | C.P. Brass stop cock concealed 15 mm | Each | 573.3 | 573.3 | 24.0 | False | None | None | False | None | False | 13759.2 | 0 |
2928345 | 96520 | None | RGU1067 | Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete. | Nos | 96.1 | 96.1 | 24.0 | False | None | None | False | None | False | 2306.4 | 0 |
2928346 | 96520 | None | RGU1068 | Providing and fixing unplasticised PVC connection pipe with brassunions : 15 mm nominal bore | Nos | 99.37 | 99.37 | 24.0 | False | None | None | False | None | False | 2384.88 | 0 |
2928347 | 96520 | None | RGU1069 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 541.63 | 541.63 | 24.0 | False | None | None | False | None | False | 12999.12 | 0 |
2928348 | 96520 | None | RGU1070 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1332.24 | 1332.24 | 23.0 | False | None | None | False | None | False | 30641.52 | 0 |
2928349 | 96520 | None | RGU1071 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | Nos | 158.34 | 158.34 | 24.0 | False | None | None | False | None | False | 3800.16 | 0 |
2928350 | 96520 | None | RGU1072 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern | Nos | 14272.44 | 14272.44 | 4.0 | False | None | None | False | None | False | 57089.76 | 0 |
2928351 | 96520 | None | RGU1073 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 312.31 | 312.31 | 2.0 | False | None | None | False | None | False | 624.62 | 0 |
2928352 | 96520 | None | RGU1074 | Providing and fixing Stainless Steel A ISI 304 188 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm | Nos | 6134.86 | 6134.86 | 1.0 | False | None | None | False | None | False | 6134.86 | 0 |
2928353 | 96520 | None | RGU1075 | Providing and fixing Sink cock with swivel spout and wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 3090.91 | 3090.91 | 1.0 | False | None | None | False | None | False | 3090.91 | 0 |
2928354 | 96520 | None | RGU1076 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 598.42 | 598.42 | 12.0 | False | None | None | False | None | False | 7181.04 | 0 |
2928355 | 96520 | None | RGU1077 | Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessories complete | Nos | 266.45 | 266.45 | 28.0 | False | None | None | False | None | False | 7460.6 | 0 |
2928356 | 96520 | None | RGU1078 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 8909.63 | 8909.63 | 1.0 | False | None | None | False | None | False | 8909.63 | 0 |
2928357 | 96520 | None | RGU1079 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 50mm nominal bore pipes, From Sink and Urinal lines | Mtr | 218.4 | 218.4 | 70.0 | False | None | None | False | None | False | 15288.0 | 0 |
2928358 | 96520 | None | RGU1080 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 532.9 | 532.9 | 190.0 | False | None | None | False | None | False | 101251.0 | 0 |
2928359 | 96520 | None | RGU1081 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 1035.22 | 1035.22 | 80.0 | False | None | None | False | None | False | 82817.6 | 0 |
2928360 | 96520 | None | RGU1082 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 50mm | Mtr | 43.68 | 43.68 | 70.0 | False | None | None | False | None | False | 3057.6 | 0 |
2928361 | 96520 | None | RGU1083 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm | Mtr | 82.99 | 82.99 | 190.0 | False | None | None | False | None | False | 15768.1 | 0 |
2928362 | 96520 | None | RGU1084 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm | Mtr | 122.3 | 122.3 | 80.0 | False | None | None | False | None | False | 9784.0 | 0 |
2928363 | 96520 | None | RGU1085 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | Mtr | 407.32 | 407.32 | 195.0 | False | None | None | False | None | False | 79427.4 | 0 |
2928364 | 96520 | None | RGU1086 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes | Mtr | 519.79 | 519.79 | 85.0 | False | None | None | False | None | False | 44182.15 | 0 |
2928365 | 96520 | None | RGU1087 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal dia Pipes | Mtr | 607.15 | 607.15 | 6.0 | False | None | None | False | None | False | 3642.9 | 0 |
2928366 | 96520 | None | RGU1088 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM Copper alloy Gate valves | Nos | 969.7 | 969.7 | 5.0 | False | None | None | False | None | False | 4848.5 | 0 |
2928367 | 96520 | None | RGU1089 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1276.55 | 1276.55 | 5.0 | False | None | None | False | None | False | 6382.75 | 0 |
2928368 | 96520 | None | RGU1090 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1461.1 | 1461.1 | 2.0 | False | None | None | False | None | False | 2922.2 | 0 |
2928369 | 96520 | None | RGU1091 | Sanitary and CP fixtures Providing and fixing white vitreous china pedestal type water closet European type W.C. pan with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device handle lever , conforming to IS : 7231, with all fittings and fix tures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid | Nos | 5333.9 | 5333.9 | 12.0 | False | None | None | False | None | False | 64006.8 | 0 |
2928370 | 96520 | None | RGU1092 | Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 925.0 | 925.0 | 12.0 | False | None | None | False | None | False | 11100.0 | 0 |
2928371 | 96520 | None | RGU1093 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps | Nos | 3397.91 | 3397.91 | 15.0 | False | None | None | False | None | False | 50968.65 | 0 |
2928372 | 96520 | None | RGU1094 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: | Nos | 337.37 | 337.37 | 32.0 | False | None | None | False | None | False | 10795.84 | 0 |
2928373 | 96520 | None | RGU1095 | C.P. Brass stop cock concealed 15 mm | Mtr | 578.81 | 578.81 | 32.0 | False | None | None | False | None | False | 18521.92 | 0 |
2928374 | 96520 | None | RGU1096 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. | Nos | 97.02 | 97.02 | 32.0 | False | None | None | False | None | False | 3104.64 | 0 |
2928375 | 96520 | None | RGU1097 | Providing and fixing unplasticised PVC connection pipe with brassunions : 15 mm nominal bore | Nos | 100.33 | 100.33 | 32.0 | False | None | None | False | None | False | 3210.56 | 0 |
2928376 | 96520 | None | RGU1098 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Nos | 546.84 | 546.84 | 32.0 | False | None | None | False | None | False | 17498.88 | 0 |
2928377 | 96520 | None | RGU1099 | Providing and fixing 600x450 mm beveled edge mirror of superior glass of approved quality complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1345.05 | 1345.05 | 15.0 | False | None | None | False | None | False | 20175.75 | 0 |
2928378 | 96520 | None | RGU1100 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. | Nos | 159.86 | 159.86 | 17.0 | False | None | None | False | None | False | 2717.62 | 0 |
2928379 | 96520 | None | RGU1101 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern | Nos | 14409.68 | 14409.68 | 3.0 | False | None | None | False | None | False | 43229.04 | 0 |
2928380 | 96520 | None | RGU1102 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 315.32 | 315.32 | 2.0 | False | None | None | False | None | False | 630.64 | 0 |
2928381 | 96520 | None | RGU1103 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm | Nos | 5602.91 | 5602.91 | 16.0 | False | None | None | False | None | False | 89646.56 | 0 |
2928382 | 96520 | None | RGU1104 | Providing and fixing Stainless Steel A ISI 304 188 kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Nos | 6193.85 | 6193.85 | 1.0 | False | None | None | False | None | False | 6193.85 | 0 |
2928383 | 96520 | None | RGU1105 | Providing and fixing Sink cock with swivel spout and wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 3181.82 | 3181.82 | 17.0 | False | None | None | False | None | False | 54090.94 | 0 |
2928384 | 96520 | None | RGU1106 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy | Nos | 604.17 | 604.17 | 12.0 | False | None | None | False | None | False | 7250.04 | 0 |
2928385 | 96520 | None | RGU1107 | Providing and fixing PVC S.W.R Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements and all necessary accessories complete | Nos | 269.01 | 269.01 | 40.0 | False | None | None | False | None | False | 10760.4 | 0 |
2928386 | 96520 | None | RGU1108 | Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements and all necessary accesories complete Class Premium | Nos | 8995.3 | 8995.3 | 1.0 | False | None | None | False | None | False | 8995.3 | 0 |
2928387 | 96520 | None | RGU1109 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 50mm nominal bore pipes, From Wash bains, Sink and Urinal lines | Mtr | 220.5 | 220.5 | 90.0 | False | None | None | False | None | False | 19845.0 | 0 |
2928388 | 96520 | None | RGU1110 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 538.02 | 538.02 | 180.0 | False | None | None | False | None | False | 96843.6 | 0 |
2928389 | 96520 | None | RGU1111 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 1045.17 | 1045.17 | 90.0 | False | None | None | False | None | False | 94065.3 | 0 |
2928390 | 96520 | None | RGU1112 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 50mm | Mtr | 44.1 | 44.1 | 90.0 | False | None | None | False | None | False | 3969.0 | 0 |
2928391 | 96520 | None | RGU1113 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 75mm | Mtr | 83.79 | 83.79 | 180.0 | False | None | None | False | None | False | 15082.2 | 0 |
2928392 | 96520 | None | RGU1114 | Sanitary piping Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 110mm | Mtr | 123.48 | 123.48 | 90.0 | False | None | None | False | None | False | 11113.2 | 0 |
2928393 | 96520 | None | RGU1115 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes | Mtr | 411.23 | 411.23 | 155.0 | False | None | None | False | None | False | 63740.65 | 0 |
2928394 | 96520 | None | RGU1116 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal dia Pipes | Mtr | 524.79 | 524.79 | 55.0 | False | None | None | False | None | False | 28863.45 | 0 |
2928395 | 96520 | None | RGU1117 | WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal dia Pipes | Mtr | 612.99 | 612.99 | 6.0 | False | None | None | False | None | False | 3677.94 | 0 |
2928396 | 96520 | None | RGU1118 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM Copper alloy Gate valves | Nos | 979.02 | 979.02 | 5.0 | False | None | None | False | None | False | 4895.1 | 0 |
2928397 | 96520 | None | RGU1119 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1288.82 | 1288.82 | 3.0 | False | None | None | False | None | False | 3866.46 | 0 |
2928398 | 96520 | None | RGU1120 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1475.15 | 1475.15 | 2.0 | False | None | None | False | None | False | 2950.3 | 0 |
2928399 | 96520 | None | RGU1121 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 20 mm nominal dia Pipes | Mtr | 227.85 | 227.85 | 60.0 | False | None | None | False | None | False | 13671.0 | 0 |
2928400 | 96520 | None | RGU1122 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 25 mm nominal dia Pipes | Mtr | 310.8 | 310.8 | 115.0 | False | None | None | False | None | False | 35742.0 | 0 |
2928401 | 96520 | None | RGU1123 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 32 mm nominal dia Pipes | Mtr | 390.6 | 390.6 | 150.0 | False | None | None | False | None | False | 58590.0 | 0 |
2928402 | 96520 | None | RGU1124 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 40 mm nominal dia Pipes | Mtr | 500.85 | 500.85 | 440.0 | False | None | None | False | None | False | 220374.0 | 0 |
2928403 | 96520 | None | RGU1125 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 50 mm nominal dia Pipes | Mtr | 757.05 | 757.05 | 745.0 | False | None | None | False | None | False | 564002.25 | 0 |
2928404 | 96520 | None | RGU1126 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 65 mm nominal dia Pipes | Mtr | 1470.0 | 1470.0 | 120.0 | False | None | None | False | None | False | 176400.0 | 0 |
2928405 | 96520 | None | RGU1127 | WATER SUPPLY WORKS Providing and fixing Chlorinated Polyvinyl Chloride CPVC pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings This includes jointing of pipes and fittings with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge. External Work 80 mm nominal dia Pipes | Mtr | 1882.65 | 1882.65 | 70.0 | False | None | None | False | None | False | 131785.5 | 0 |
2928406 | 96520 | None | RGU1128 | Supplying and fixing surface box of required dia. and size with synthetic lid for valves or spindle rods. The surface box should be usable for 50 to 400mm dia. valves, PN 10 16 and will consist of lid, housing, locking clip, notched bolt, cross bar, washer and torque nut. | Nos | 3573.15 | 3573.15 | 1.0 | False | None | None | False | None | False | 3573.15 | 0 |
2928407 | 96520 | None | RGU1129 | B098ASupply and fixing RCC Precast Cover Slab of size 0.8 m x 0.8 m x 0.2m of M25Design mix concrete with 12 mm steel at 120 mm cc both ways, over Gate valve extension spindle with central opening along with lid for smooth operation with appurtenances., complete with all lead and lifts. | Nos | 3034.5 | 3034.5 | 1.0 | False | None | None | False | None | False | 3034.5 | 0 |
2928408 | 96520 | None | RGU1130 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM Copper alloy Gate valves | Nos | 932.4 | 932.4 | 10.0 | False | None | None | False | None | False | 9324.0 | 0 |
2928409 | 96520 | None | RGU1131 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 25 mm dia GM Copper alloy Gate valves | Nos | 1227.45 | 1227.45 | 9.0 | False | None | None | False | None | False | 11047.05 | 0 |
2928410 | 96520 | None | RGU1132 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 32 mm dia GM Copper alloy Gate valves | Nos | 1404.9 | 1404.9 | 6.0 | False | None | None | False | None | False | 8429.4 | 0 |
2928411 | 96520 | None | RGU1133 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 40 mm dia GM Copper alloy Gate valves | Nos | 1575.0 | 1575.0 | 9.0 | False | None | None | False | None | False | 14175.0 | 0 |
2928412 | 96520 | None | RGU1134 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM Copper alloy Gate valves | Nos | 1772.4 | 1772.4 | 12.0 | False | None | None | False | None | False | 21268.8 | 0 |
2928413 | 96520 | None | RGU1135 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 65 mm dia GM Copper alloy Gate valves | Nos | 1962.45 | 1962.45 | 1.0 | False | None | None | False | None | False | 1962.45 | 0 |
2928414 | 96520 | None | RGU1136 | Supply and delivery at site GM copper alloy gate valves confirming to ClassI as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 80 mm dia GM Copper alloy Gate valves | Nos | 1997.1 | 1997.1 | 1.0 | False | None | None | False | None | False | 1997.1 | 0 |
2928415 | 96520 | None | RGU1137 | Providing GM copper alloy reflex valvesglobe valves confirming to ClassI and as per IS 7781990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP. For 32 mm dia GM Copper alloy reflex valve | Nos | 636.3 | 636.3 | 1.0 | False | None | None | False | None | False | 636.3 | 0 |
2928416 | 96520 | None | RGU1138 | Providing GM copper alloy reflex valvesglobe valves confirming to ClassI and as per IS 7781990 with latest amendments, 1 No. and with ISI mark screwed female ends confirming to IS 554 1990 horizontal body hydraulically tested for 1.50 HP and seat hydraulically tested 1 HP. For 50 mm dia GM Copper alloy reflex valve | Nos | 833.7 | 833.7 | 7.0 | False | None | None | False | None | False | 5835.9 | 0 |
2928417 | 96520 | None | RGU1139 | Earth work excavation for pipelinescables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. In all kinds of soils, depth up to 1.50m | Cum | 572.25 | 572.25 | 15.0 | False | None | None | False | None | False | 8583.75 | 0 |
2928418 | 96520 | None | RGU1140 | Filling approved earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 15.0 | False | None | None | False | None | False | 6819.75 | 0 |
2928419 | 96520 | None | RGU1141 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore | Nos | 300.3 | 300.3 | 10.0 | False | None | None | False | None | False | 3003.0 | 0 |
2928420 | 96520 | None | RGU1142 | SANITARY PIPING WORKS Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 50mm dia., 6 kgsqcm and class 3 Vent pipe | Mtr | 210.0 | 210.0 | 55.0 | False | None | None | False | None | False | 11550.0 | 0 |
2928421 | 96520 | None | RGU1143 | SANITARY PIPING WORKS Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 75mm dia., 6 kgsqcm and class 3 Waste pipe | Mtr | 512.4 | 512.4 | 205.0 | False | None | None | False | None | False | 105042.0 | 0 |
2928422 | 96520 | None | RGU1144 | SANITARY PIPING WORKS Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 Soil pipe | Mtr | 995.4 | 995.4 | 220.0 | False | None | None | False | None | False | 218988.0 | 0 |
2928423 | 96520 | None | RGU1145 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 50mm Vent pipe | Mtr | 42.0 | 42.0 | 55.0 | False | None | None | False | None | False | 2310.0 | 0 |
2928424 | 96520 | None | RGU1146 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm Waste pipe | Mtr | 79.8 | 79.8 | 205.0 | False | None | None | False | None | False | 16359.0 | 0 |
2928425 | 96520 | None | RGU1147 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm Soil pipe | Mtr | 117.6 | 117.6 | 220.0 | False | None | None | False | None | False | 25872.0 | 0 |
2928426 | 96520 | None | RGU1148 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. for: For external Sanitary Work . Sewer line Block Water Pipes of SN4, 160mm dia. | Mtr | 604.8 | 604.8 | 205.0 | False | None | None | False | None | False | 123984.0 | 0 |
2928427 | 96520 | None | RGU1149 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. for: For external Sanitary Work . Sewer line Block Water Pipes of SN4, 160mm dia. | Mtr | 604.8 | 604.8 | 205.0 | False | None | None | False | None | False | 123984.0 | 0 |
2928428 | 96520 | None | RGU1150 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover. | Nos | 5219.55 | 5219.55 | 15.0 | False | None | None | False | None | False | 78293.25 | 0 |
2928429 | 96520 | None | RGU1151 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover.. INSPECTION CHAMBER | Nos | 5726.7 | 5726.7 | 12.0 | False | None | None | False | None | False | 68720.4 | 0 |
2928430 | 96520 | None | RGU1152 | Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.0 M depth and SFRC cover and frame | Nos | 30499.35 | 30499.35 | 1.0 | False | None | None | False | None | False | 30499.35 | 0 |
2928431 | 96520 | None | RGU1153 | Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. ,1.1 M depth and SFRC cover and frame | Nos | 31007.55 | 31007.55 | 1.0 | False | None | None | False | None | False | 31007.55 | 0 |
2928432 | 96520 | None | RGU1154 | Earth work excavation for pipelinescables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. In all kinds of soils, depth up to 1.50m | Cum | 493.5 | 493.5 | 111.0 | False | None | None | False | None | False | 54778.5 | 0 |
2928433 | 96520 | None | RGU1155 | Filling approved earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 455.0 | 455.0 | 111.0 | False | None | None | False | None | False | 50505.0 | 0 |
2928434 | 96520 | None | RGU1156 | RAIN WATER PIPING WORKS Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 75mm dia., 6 kgsqcm and class 3 | Mtr | 512.4 | 512.4 | 6.0 | False | None | None | False | None | False | 3074.4 | 0 |
2928435 | 96520 | None | RGU1157 | RAIN WATER PIPING WORKS Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 110mm dia., 6 kgsqcm and class 3 | Mtr | 995.4 | 995.4 | 10.0 | False | None | None | False | None | False | 9954.0 | 0 |
2928436 | 96520 | None | RGU1158 | RAIN WATER PIPING WORKS Providing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. PVC pipes 160mm dia., 6 kgsqcm and class 3 | Mtr | 1424.85 | 1424.85 | 265.0 | False | None | None | False | None | False | 377585.25 | 0 |
2928437 | 96520 | None | RGU1159 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 75mm | Mtr | 79.8 | 79.8 | 6.0 | False | None | None | False | None | False | 478.8 | 0 |
2928438 | 96520 | None | RGU1160 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 110mm | Mtr | 117.6 | 117.6 | 10.0 | False | None | None | False | None | False | 1176.0 | 0 |
2928439 | 96520 | None | RGU1161 | Lowering, laying true to line and level of PVC Ringtite PVC Pipes and cuts of pipes wherever necessary including jointing of pipes and specials with jointing of approved type, with all labour with encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS and commissioning Contractor will make his own arrangements for procuring water for testing etc. for: 160mm | Mtr | 132.3 | 132.3 | 265.0 | False | None | None | False | None | False | 35059.5 | 0 |
2928440 | 96520 | None | RGU1162 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover. CATCH BASIN | Nos | 5726.7 | 5726.7 | 12.0 | False | None | None | False | None | False | 68720.4 | 0 |
2928441 | 96520 | None | RGU1163 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. for: For external Sanitary Work . Pipes of SN4, 160mm dia. | Mtr | 604.8 | 604.8 | 95.0 | False | None | None | False | None | False | 57456.0 | 0 |
2928442 | 96520 | None | RGU1164 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes with cost of elastomeric sealing rings and specials excluding cost of specials with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS contractor will make his own arrangements for procuring water for testing etc. for: For external Sanitary Work . Pipes of SN4, 200mm dia. | Mtr | 872.55 | 872.55 | 110.0 | False | None | None | False | None | False | 95980.5 | 0 |
2928443 | 96520 | None | RGU1165 | Earth work excavation for pipelinescables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage and other appurtenances required to complete the work. In all kinds of soils, depth up to 1.50m | Cum | 572.25 | 572.25 | 67.9 | False | None | None | False | None | False | 38855.775 | 0 |
2928444 | 96520 | None | RGU1166 | Filling approved earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 70.0 | False | None | None | False | None | False | 31825.5 | 0 |
2928445 | 96520 | None | RGU1167 | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD577. Jaguar make or Equalent . GF Toilet | Nos | 1950.0 | 1950.0 | 11.0 | False | None | None | False | None | False | 21450.0 | 0 |
2928446 | 96520 | None | RGU1168 | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD577. Jaguar make or Equalent . 1F Toilet | Nos | 1950.0 | 1950.0 | 10.0 | False | None | None | False | None | False | 19500.0 | 0 |
2928447 | 96520 | None | RGU1169 | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD577. Jaguar make or Equalent . 2F Toilet | Nos | 1950.0 | 1950.0 | 12.0 | False | None | None | False | None | False | 23400.0 | 0 |
2928448 | 96520 | None | RGU1170 | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD577. Jaguar make or Equalent . 3F Toilet | Nos | 1950.0 | 1950.0 | 12.0 | False | None | None | False | None | False | 23400.0 | 0 |
2928449 | 96520 | None | RGU1171 | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD577. Jaguar make or Equalent . 4F Toilet | Nos | 1950.0 | 1950.0 | 12.0 | False | None | None | False | None | False | 23400.0 | 0 |
2928450 | 96520 | None | RGU1172 | Sanitary and CP fixtures Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit instant type CP Crutch etc., complete as directed by the Engineer in charge. ALD577. Jaguar make or Equalent . 5F Toilet | Nos | 1950.0 | 1950.0 | 12.0 | False | None | None | False | None | False | 23400.0 | 0 |
2928451 | 96520 | None | RGU1173 | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. Thequoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,. 1 no. working and 1no. Standby Sump To OHT DOMESTIC 5.0 HP x 02 Nos 01 Working and 01 Stand by pumps. | Nos | 85500.0 | 85500.0 | 2.0 | False | None | None | False | None | False | 171000.0 | 0 |
2928452 | 96520 | None | RGU1174 | Supplying, installing, testing and commissioning approved make Submersible Pump made of C.I Construction suitable for building application. The quoted rate shall also include for auto lvl.controller with cabling between hePumps, control panel, UGR and OHT etc.,. complete.approx. Length of cable = 80. providing necessary safety devices viz. dry run protection, over load relays etc., complete working on 230V, 50Hz, 1Ph, with starter,. 1 no. working and 1no. Standby Sump To OHT Flushing water 5HP x 02 Nos 01 Working and 01 Stand by pumps. | Nos | 85500.0 | 85500.0 | 2.0 | False | None | None | False | None | False | 171000.0 | 0 |
2928453 | 96520 | None | RGU1175 | Making openings of the following diameters RCC beamsslab using core cutters having diamond edged core bits and redoing the same after fixing of pipes with PVC rings grouting with nonshrink grouts etc., comp lete including ensuring water tightness of the system. FF TOILET | Nos | 850.0 | 850.0 | 4.0 | False | None | None | False | None | False | 3400.0 | 0 |
2928454 | 96520 | None | RGU1176 | Making openings of the following diameters RCC beamsslab using core cutters having diamond edged core bits and redoing the same after fixing of pipes with PVC rings grouting with nonshrink grouts etc., comp lete including ensuring water tightness of the system. SF TOILET | Nos | 850.0 | 850.0 | 12.0 | False | None | None | False | None | False | 10200.0 | 0 |
2928455 | 96520 | None | RGU1177 | Making openings of the following diameters RCC beamsslab using core cutters having diamond edged core bits and redoing the same after fixing of pipes with PVC rings grouting with nonshrink grouts etc., comp lete including ensuring water tightness of the system. TF TOILET | Nos | 850.0 | 850.0 | 12.0 | False | None | None | False | None | False | 10200.0 | 0 |
2928456 | 96520 | None | RGU1178 | Packing the core openings in slabs and beams by providing PVC pipes and filling the void after fixing the pipe by packing with polymer concrete or non shrink grout etc,. Complete ensuring water tightness in the joint.The core cut area of the slab shall be prepared rough also same treatment on the puddle pipe to be made to ensure proper bonding. FF TOILET | Nos | 950.0 | 950.0 | 4.0 | False | None | None | False | None | False | 3800.0 | 0 |
2928457 | 96520 | None | RGU1179 | Packing the core openings in slabs and beams by providing PVC pipes and filling the void after fixing the pipe by packing with polymer concrete or non shrink grout etc,. Complete ensuring water tightness in the joint.The core cut area of the slab shall be prepared rough also same treatment on the puddle pipe to be made to ensure proper bonding. SF TOILET | Nos | 950.0 | 950.0 | 12.0 | False | None | None | False | None | False | 11400.0 | 0 |
2928458 | 96520 | None | RGU1180 | Packing the core openings in slabs and beams by providing PVC pipes and filling the void after fixing the pipe by packing with polymer concrete or non shrink grout etc,. Complete ensuring water tightness in the joint.The core cut area of the slab shall be prepared rough also same treatment on the puddle pipe to be made to ensure proper bonding. TF TOILET | Nos | 950.0 | 950.0 | 12.0 | False | None | None | False | None | False | 11400.0 | 0 |
2928459 | 96520 | None | RGU1181 | Packing the core openings in slabs and beams by providing PVC pipes and filling the void after fixing the pipe by packing with polymer concrete or non shrink grout etc,. Complete ensuring water tightness in the joint.The core cut area of the slab shall be prepared rough also same treatment on the puddle pipe to be made to ensure proper bonding. FF TOILET | Nos | 950.0 | 950.0 | 10.0 | False | None | None | False | None | False | 9500.0 | 0 |
2928460 | 96520 | None | RGU1182 | Packing the core openings in slabs and beams by providing PVC pipes and filling the void after fixing the pipe by packing with polymer concrete or non shrink grout etc,. Complete ensuring water tightness in the joint.The core cut area of the slab shall be prepared rough also same treatment on the puddle pipe to be made to ensure proper bonding. 5TH TOILET | Nos | 950.0 | 950.0 | 10.0 | False | None | None | False | None | False | 9500.0 | 0 |
2928461 | 96520 | None | RGU1183 | Air Vent Cowel 75mm | Nos | 125.0 | 125.0 | 8.0 | False | None | None | False | None | False | 1000.0 | 0 |
2928462 | 96520 | None | RGU1184 | Air Vent Cowel 110mm | Nos | 165.0 | 165.0 | 3.0 | False | None | None | False | None | False | 495.0 | 0 |
2928463 | 96520 | None | RGU1185 | Supplying, fixing, testing and commissioning of portable Water Cooler Floor mounted model in corridors for drinking water with all the necessary accessories etc. GF | Nos | 18000.0 | 18000.0 | 2.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928464 | 96520 | None | RGU1186 | Supplying, fixing, testing and commissioning of portable Water Cooler Floor mounted model in corridors for drinking water with all the necessary accessories etc. FF | Nos | 18000.0 | 18000.0 | 2.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928465 | 96520 | None | RGU1187 | Supplying, fixing, testing and commissioning of portable Water Cooler Floor mounted model in corridors for drinking water with all the necessary accessories etc. SF | Nos | 18000.0 | 18000.0 | 2.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928466 | 96520 | None | RGU1188 | Supplying, fixing, testing and commissioning of portable Water Cooler Floor mounted model in corridors for drinking water with all the necessary accessories etc. TF | Nos | 18000.0 | 18000.0 | 2.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928467 | 96520 | None | RGU1189 | Supplying, fixing, testing and commissioning of portable Water Cooler Floor mounted model in corridors for drinking water with all the necessary accessories etc. FF | Nos | 18000.0 | 18000.0 | 2.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928468 | 96520 | None | RGU1190 | Supplying, fixing, testing and commissioning of portable Water Cooler Floor mounted model in corridors for drinking water with all the necessary accessories etc. 5TH FLOOR | Nos | 18000.0 | 18000.0 | 2.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928469 | 96520 | None | RGU1191 | Supplying and fixing in position solid block masonry pedestals of approaximate size 400x230x230mm with brackets and G.I clamps for laying pipes on terrace. etc,. complete as directed by the Engineer in charge. | Nos | 600.0 | 600.0 | 125.0 | False | None | None | False | None | False | 75000.0 | 0 |
2928470 | 96520 | None | RGU1192 | Supply and fixing of GM ball cock with copper float High pressure float of approved brand of manufacture and fixed on to the inlet pipe at the underground sump tank and OHT. 50mm die | Nos | 3525.0 | 3525.0 | 1.0 | False | None | None | False | None | False | 3525.0 | 0 |
2928471 | 96520 | None | RGU1193 | Note: The length of the bracket shall be equal to the sum of the outer diameters of all pipe and 50mm for working space per pipe of size 15 to 75mm and 100mm for working space per pipe for pipes of size 75mm and above diameters. | Kg | 140.0 | 140.0 | 350.0 | False | None | None | False | None | False | 49000.0 | 0 |
2928472 | 96520 | None | RGU1194 | Supplying and fixing of SS Grab bar Right 90ºAngle L shape with all Accessories For Disablefriendly Bathroom Make: Jaquar, Cat. No.: WACSAPBG0800CS and AHS 1507. GF | Nos | 6985.0 | 6985.0 | 1.0 | False | None | None | False | None | False | 6985.0 | 0 |
2928473 | 96520 | None | RGU1195 | Supplying and fixing of SS Grab bar Right 90ºAngle L shape with all Accessories For Disablefriendly Bathroom Make: Jaquar, Cat. No.: WACSAPBG0800CS and AHS 1507. FF | Nos | 6985.0 | 6985.0 | 1.0 | False | None | None | False | None | False | 6985.0 | 0 |
2928474 | 96520 | None | RGU1196 | Supplying and fixing of SS Grab bar Right 90ºAngle L shape with all Accessories For Disablefriendly Bathroom Make: Jaquar, Cat. No.: WACSAPBG0800CS and AHS 1507. SF | Nos | 6985.0 | 6985.0 | 1.0 | False | None | None | False | None | False | 6985.0 | 0 |
2928475 | 96520 | None | RGU1197 | Supplying and fixing of SS Grab bar Right 90ºAngle L shape with all Accessories For Disablefriendly Bathroom Make: Jaquar, Cat. No.: WACSAPBG0800CS and AHS 1507. TF | Nos | 6985.0 | 6985.0 | 1.0 | False | None | None | False | None | False | 6985.0 | 0 |
2928476 | 96520 | None | RGU1198 | Supplying and fixing of SS Grab bar Right 90ºAngle L shape with all Accessories For Disablefriendly Bathroom Make: Jaquar, Cat. No.: WACSAPBG0800CS and AHS 1507. FF | Nos | 6985.0 | 6985.0 | 1.0 | False | None | None | False | None | False | 6985.0 | 0 |
2928477 | 96520 | None | RGU1199 | Supplying and fixing of SS Grab bar Right 90ºAngle L shape with all Accessories For Disablefriendly Bathroom Make: Jaquar, Cat. No.: WACSAPBG0800CS and AHS 1507. 5TH Floor | Nos | 6985.0 | 6985.0 | 1.0 | False | None | None | False | None | False | 6985.0 | 0 |
2928478 | 96520 | None | RGU1200 | Rain harvest pit of size 1200 mm dia and 6 m deep is proposed to be constructed. The rain water harvest pit consists of 300 mm deep RCC precast rings along with 50mm dia holes from the invert level of percolation pit. The pit outer wall is constructed in precast RCC and crushed stone of 200mm thick all around it on PCC bed of 1:4:8 ratio. The first layer for 600mm thick is left hollow with 50mm dia holes around it. The second layer for 600mm thick is filled with 40mm gravel filling. The third layer for 600mm thick is filled with 65mm gravel filling. The fourth layer for 900mm thick is filled with brick bats. Finally the top of rain harvest pit is covered with RCC precast slab with perforation of min 50 mm dia in strip of size 2’0’ wide, to allow entry of surface ground level rainwater. | Nos | 52500.0 | 52500.0 | 7.0 | False | None | None | False | None | False | 367500.0 | 0 |
2928479 | 96520 | None | RGU1201 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1 Additional rate on item 1 and2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M for fixing Casing pipes only a Above M and upto 30 M 15percent,b Above 30 M 30percent Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level . 2 A sum of R . 100 is to be deducted for Dry Borewell towards yield test. tc. complete. | Each | 5552.4 | 5552.4 | 2.0 | False | None | None | False | None | False | 11104.8 | 0 |
2928480 | 96520 | None | RGU1202 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 0 to 50 Mtrs | Rmtr | 388.5 | 388.5 | 100.0 | False | None | None | False | None | False | 38850.0 | 0 |
2928481 | 96520 | None | RGU1203 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 50 to 100 Mtrs | Rmtr | 487.2 | 487.2 | 100.0 | False | None | None | False | None | False | 48720.0 | 0 |
2928482 | 96520 | None | RGU1204 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 100 to 150 Mtrs | Rmtr | 517.65 | 517.65 | 100.0 | False | None | None | False | None | False | 51765.0 | 0 |
2928483 | 96520 | None | RGU1205 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 150 to 200 Mtrs | Rmtr | 600.6 | 600.6 | 100.0 | False | None | None | False | None | False | 60060.0 | 0 |
2928484 | 96520 | None | RGU1206 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 200 to 250 Mtrs | Rmtr | 704.55 | 704.55 | 100.0 | False | None | None | False | None | False | 70455.0 | 0 |
2928485 | 96520 | None | RGU1207 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 250 to 300 Mtrs | Rmtr | 777.0 | 777.0 | 100.0 | False | None | None | False | None | False | 77700.0 | 0 |
2928486 | 96520 | None | RGU1208 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour Excluding cost of casing pipes, collars, cap etc., complete Above 450m of drilling add 10percent for every 50m depth Borewell depth of 300 to 350 Mtrs | Rmtr | 911.4 | 911.4 | 100.0 | False | None | None | False | None | False | 91140.0 | 0 |
2928487 | 96520 | None | RGU1209 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 42702001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 13871993 and manufactured by basic open hearth electric or basic oxygen process in random length of 57m both ends.threaded conforming to IS 5541985 one end fixe with socket conforming to IS 42702001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kgm.prices include CollarMedium duty. | Mtr | 2029.65 | 2029.65 | 70.0 | False | None | None | False | None | False | 142075.5 | 0 |
2928488 | 96520 | None | RGU1210 | Supply and delivery at site 50mm 2” dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. | Rmtr | 577.5 | 577.5 | 401.0 | False | None | None | False | None | False | 231577.5 | 0 |
2928489 | 96520 | None | RGU1211 | Providing and fixing MS casing collars per IS 1239 partII 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm minimum . The dimensions of caps and colars shall be strictly as per IS 1239 PartII 1982 with all amendments. | Nos | 157.5 | 157.5 | 2.0 | False | None | None | False | None | False | 315.0 | 0 |
2928490 | 96520 | None | RGU1212 | Providing and laying at site of wor MS asing caps as per IS 1239 part II 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm minimum . The dimensions of caps and olars shall be strictly as per IS 1239 PartII 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge. | Nos | 172.2 | 172.2 | 2.0 | False | None | None | False | None | False | 344.4 | 0 |
2928491 | 96520 | None | RGU1213 | Providing NPCP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions Rates includes cost of materials fixtures and conveyance to work spot etc complete | Nos | 220.5 | 220.5 | 2.0 | False | None | None | False | None | False | 441.0 | 0 |
2928492 | 96520 | None | RGU1214 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 80342000,3Phase, SS Bowl and Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP 90 LPM at 110 m = 15 STG Outlet Dia 2.00inches | Each | 33743.85 | 33743.85 | 2.0 | False | None | None | False | None | False | 67487.7 | 0 |
2928493 | 96520 | None | RGU1215 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of SD Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current and dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1 DOL Direct Online Starter2 SD Star Delta Starter etc. complete.3 to 6 HP pumps | Each | 10027.5 | 10027.5 | 2.0 | False | None | None | False | None | False | 20055.0 | 0 |
2928494 | 96520 | None | RGU1216 | Supply and delivery at site 50mm 2” dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets | Set | 1627.5 | 1627.5 | 2.0 | False | None | None | False | None | False | 3255.0 | 0 |
2928495 | 96520 | None | RGU1217 | Supply and delivery at site Stringing of heavy duty NaylonePP rope with ISI etc complete suitable for Single phase Pumpsets. | Job | 42.0 | 42.0 | 200.0 | False | None | None | False | None | False | 8400.0 | 0 |
2928496 | 96520 | None | RGU1218 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6825.0 | 6825.0 | 2.0 | False | None | None | False | None | False | 13650.0 | 0 |
2928497 | 96520 | None | RGU1219 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundationbed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1417.5 | 1417.5 | 2.0 | False | None | None | False | None | False | 2835.0 | 0 |
2928498 | 96520 | None | RGU1220 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:81301984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS694:1990.3C x 4 mm2 | Mtr | 176.4 | 176.4 | 550.0 | False | None | None | False | None | False | 97020.0 | 0 |
2928499 | 96520 | None | RGU1221 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG | Sq CM | 0.45 | 0.45 | 60000.0 | False | None | None | False | None | False | 27000.0 | 0 |
2928500 | 96520 | None | RGU1222 | Supply and Installation Fixing Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 Weather Proof , rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase Three Phase Energy Meter in suitable base plate and having a provision for Fuse MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. | Each | 15246.0 | 15246.0 | 2.0 | False | None | None | False | None | False | 30492.0 | 0 |
2928501 | 96520 | None | RGU1223 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20inches x 20inches x 2.5inches | Each | 342.44 | 342.44 | 2.0 | False | None | None | False | None | False | 684.88 | 0 |
2928502 | 96520 | None | RGU1224 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.632 A SP | Each | 435.75 | 435.75 | 2.0 | False | None | None | False | None | False | 871.5 | 0 |
2928503 | 96520 | None | RGU1225 | Fixing of ..... A TPST change over switch Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..15A to 63A TPST | Each | 291.9 | 291.9 | 2.0 | False | None | None | False | None | False | 583.8 | 0 |
2928504 | 96520 | None | RGU1226 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400440 V grade, for power factor improvement of rotating machineries like induction motor. | Kvar | 504.0 | 504.0 | 2.0 | False | None | None | False | None | False | 1008.0 | 0 |
2928505 | 96520 | None | RGU1227 | Supply and installation of Filter Feed PumpsMake: Kirloskar, KDS SeriesCapacity: 5.0 HP3.0 PH | No | 36800.0 | 36800.0 | 2.0 | False | None | None | False | None | False | 73600.0 | 0 |
2928506 | 96520 | None | RGU1228 | Motor for Air blowerMake: KirloskarCapacity: 5 HP of 1440 rpm as recommended | No | 28175.0 | 28175.0 | 2.0 | False | None | None | False | None | False | 56350.0 | 0 |
2928507 | 96520 | None | RGU1229 | Supply and installation of Fine buble diffusers Disc diffusers long with membrane.Make: Southern cogen | Nos | 7475.0 | 7475.0 | 8.0 | False | None | None | False | None | False | 59800.0 | 0 |
2928508 | 96520 | None | RGU1230 | Supply and installation of Course buble diffusers Disc diffusers long with membrane.Make: Southern cogen | Nos | 2472.5 | 2472.5 | 4.0 | False | None | None | False | None | False | 9890.0 | 0 |
2928509 | 96520 | None | RGU1231 | Supply of Root Blower.Type: Twin Lobe Air CompressorMake: KAYEverestinchesAccessories: base frame, suction filter, suction and discharge silencer, NR valve, safety valve, set of V belt drive etc. inchesFlow Media: Air, 80 cubicmeterMaterial of Impeller: CIDirection of Flow: VerticalDischarge Pressure: 0.5 Kgcm2 | No | 100625.0 | 100625.0 | 2.0 | False | None | None | False | None | False | 201250.0 | 0 |
2928510 | 96520 | None | RGU1232 | Supply and installation of Sludge Recirculation Pump Duty: 1.0 H.P at 3.0 P.H, Make: SR Pumps | No | 32775.0 | 32775.0 | 1.0 | False | None | None | False | None | False | 32775.0 | 0 |
2928511 | 96520 | None | RGU1233 | Supply and installation of Pressure Sand Filters Size:600mm dia x 1000mm ht | No | 120750.0 | 120750.0 | 1.0 | False | None | None | False | None | False | 120750.0 | 0 |
2928512 | 96520 | None | RGU1234 | Supply and installation of Activated Carbon Filter Size:600mm dia x 1000mm ht | No | 132250.0 | 132250.0 | 1.0 | False | None | None | False | None | False | 132250.0 | 0 |
2928513 | 96520 | None | RGU1235 | M.S bar screen size: 40 X 8 SS flat and inside with 20 X 5 MS flat with handle rake arm to fit to installed bar screen chamber . | No | 13800.0 | 13800.0 | 1.0 | False | None | None | False | None | False | 13800.0 | 0 |
2928514 | 96520 | None | RGU1236 | Supply and installation of Chlorine dosing pumpCapacity: 6lphMake : Innovative | No | 28750.0 | 28750.0 | 1.0 | False | None | None | False | None | False | 28750.0 | 0 |
2928515 | 96520 | None | RGU1237 | Supply and installation of Electrical Panel boardUt door mount with ammeter, volt meters etc. | No | 327750.0 | 327750.0 | 1.0 | False | None | None | False | None | False | 327750.0 | 0 |
2928516 | 96520 | None | RGU1238 | Supply and installation of Plant piping GI and CPVC | Lot | 161000.0 | 161000.0 | 1.0 | False | None | None | False | None | False | 161000.0 | 0 |
2928517 | 96520 | None | RGU1239 | Supply and installation of Power Wiring | Lot | 28750.0 | 28750.0 | 1.0 | False | None | None | False | None | False | 28750.0 | 0 |
2928518 | 96520 | None | RGU1240 | Supply and installation of Plant Plumbing work | Lot | 46000.0 | 46000.0 | 1.0 | False | None | None | False | None | False | 46000.0 | 0 |
2928519 | 96520 | None | RGU1241 | Decant Mechanism, Motor operated valve | Lot | 97750.0 | 97750.0 | 1.0 | False | None | None | False | None | False | 97750.0 | 0 |
2928520 | 96520 | None | RGU1242 | Maintenace for one month, showing complete operation and the test report of final treated water. | Lot | 57500.0 | 57500.0 | 1.0 | False | None | None | False | None | False | 57500.0 | 0 |
2928521 | 96520 | None | RGU1243 | Water level controller Providing and fixing water level controller with auto change over from working and stand by pump of approved make, MAKE: Pioneer controller, 3phase | Nos | 18000.0 | 18000.0 | 1.0 | False | None | None | False | None | False | 18000.0 | 0 |
2928522 | 96520 | None | RGU1244 | Providing and fixing of filter feed pump having duty and head rating as mentioned of approved make. The pump shall be supplied with all necessary accessories like connectors, rubber bushes, foundation bolts, base mounting assembly as may be necessary for the installation of the pump.Capacity: 8.62 m3hr, Head: 30mtrs, Head: 30mtrs, Centrifugal Pump 2 no, 3.75 HP | Nos | 16000.0 | 16000.0 | 2.0 | False | None | None | False | None | False | 32000.0 | 0 |
2928523 | 96520 | None | RGU1245 | Pressure sand filter Providing and fixing Pressure Sand Filter of flow rate as mentioned with MS pressure vessel with FRP coating inside of approved make as per specification with high quality filter grade media, distribution, collection system with strainer, Size: 600 x 1250mm Make: LEPS | Nos | 185000.0 | 185000.0 | 1.0 | False | None | None | False | None | False | 185000.0 | 0 |
2928524 | 96520 | None | RGU1246 | Softener Providing and fixing water softener of flow rate as mentioned with MS pressure vessel with FRP coating inside the filter of approved make as per specification. Make: MS filter with MULTIPORT VALVE. Resin: Ion exchange, 220NA. Size : 600 x 1500mm | Nos | 175000.0 | 175000.0 | 1.0 | False | None | None | False | None | False | 175000.0 | 0 |
2928525 | 96520 | None | RGU1247 | Brine solution tank Providing and fixing double layer rotational moulded vertical cylindrical water tank of capacity as mentioned below made from virgin grade PE polymer with inlet connection from soft water line and outlet to connect to brine feed pump, including cost of making inlet and outlet connections using PVC PPR tank connectors of approved make, hoisting, transportation etc., complete. | No | 18000.0 | 18000.0 | 1.0 | False | None | None | False | None | False | 18000.0 | 0 |
2928526 | 96520 | None | RGU1248 | ELECTRICAL WORKS Providing the following electrical works necessary for suitable operation of the plant as per specification, design and relavant standards etc., Cabling: FinolexPolycab. Earthing from clients | Nos | 80000.0 | 80000.0 | 1.0 | False | None | None | False | None | False | 80000.0 | 0 |
2928527 | 96520 | None | RGU1249 | Supply, installation, testing and commissioning of electronic Chlorine dosing unit with automatically operated dosing pump etc. Make: Edose | No | 15000.0 | 15000.0 | 1.0 | False | None | None | False | None | False | 15000.0 | 0 |
2928528 | 96520 | None | RGU1250 | Drain pump 1hp, 3phase, | Nos | 62500.0 | 62500.0 | 1.0 | False | None | None | False | None | False | 62500.0 | 0 |
2928529 | 96520 | None | RGU1251 | Chlorine dosing pump, Make: edose, capacity:46lph With 100 ltrs storage tank | Nos | 45000.0 | 45000.0 | 1.0 | False | None | None | False | None | False | 45000.0 | 0 |
2928530 | 96520 | None | RGU1252 | Digital flow meter, Make, Kranthi, Display boards, Flow sheet and Plan copy in A1 size, Flow direction stickers | Nos | 15000.0 | 15000.0 | 1.0 | False | None | None | False | None | False | 15000.0 | 0 |
2928531 | 96520 | None | RGU1253 | Plant piping and plumbing work, providing puddle flanges, butterfly valve and CPVC piping, Make: Astral pipes | Lot | 85000.0 | 85000.0 | 1.0 | False | None | None | False | None | False | 85000.0 | 0 |
2928532 | 96520 | None | RGU1254 | 3D 90mm Thick SS Mirror finish gold channel letters internally illuminated with LEDs and fixed directly on the surface Dimensions as per site conditions. Reception BillingBackdrop | Nos | 225400.0 | 225400.0 | 1.0 | False | None | None | False | None | False | 225400.0 | 0 |
2928533 | 96520 | None | RGU1255 | Acid Etching on SS fixed on Acrylic. Floor Directory | Nos | 12800.0 | 12800.0 | 6.0 | False | None | None | False | None | False | 76800.0 | 0 |
2928534 | 96520 | None | RGU1256 | Acrylic Signage. Lift Identiciation | Nos | 2500.0 | 2500.0 | 2.0 | False | None | None | False | None | False | 5000.0 | 0 |
2928535 | 96520 | None | RGU1257 | SS Acid etching Information Signage | Nos | 7500.0 | 7500.0 | 12.0 | False | None | None | False | None | False | 90000.0 | 0 |
2928536 | 96520 | None | RGU1258 | 5MM Sunboard with vinyl. Mandatory Signage A4 | Nos | 1500.0 | 1500.0 | 12.0 | False | None | None | False | None | False | 18000.0 | 0 |
2928537 | 96520 | None | RGU1259 | 5MM Sunboard with vinyl.Mandatory Signage A0 | Nos | 2500.0 | 2500.0 | 12.0 | False | None | None | False | None | False | 30000.0 | 0 |
2928538 | 96520 | None | RGU1260 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing thickness typically to be 30 microns. The integrity to meet international specifications ISO 21431981 with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glareglossy finish. Size 210 X 700. ON THE BUILDING. BUILDING SIGNAGE | Nos | 355700.0 | 355700.0 | 1.0 | False | None | None | False | None | False | 355700.0 | 0 |
2928539 | 96520 | None | RGU1261 | Aluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing thickness typically to be 30 microns. The integrity to meet international specifications ISO 21431981 with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glareglossy finish. Size 1200 X 3600. IN THE CAMPUS. ENTRY WAY FINDING SIGNAGE | Nos | 95400.0 | 95400.0 | 1.0 | False | None | None | False | None | False | 95400.0 | 0 |
2928540 | 96520 | None | RGU1262 | Supplying of ..... TR Invertor type split Air conditioners suitable for operation on AC supply single phase 230V50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A R32 Refrigerant fan motor, start and run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathedPVC copper cable and a battery operated wireless remote unit. 5 Star.2.0 Ton capacity. | Nos | 70768.95 | 70768.95 | 12.0 | False | None | None | False | None | False | 849227.4 | 0 |
2928541 | 96520 | None | RGU1263 | Supply, erection, testing, commissioning of package type Duct able type split AirConditioner with microprocessor control, fitted with twin scroll Compressor with R22Latest Refrigerant. The unit shall be prewired to operate on 415V50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, IndoorOutdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.11.0 TR | Nos | 222721.8 | 222721.8 | 2.0 | False | None | None | False | None | False | 445443.6 | 0 |
2928542 | 96520 | None | RGU1264 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable angle iron support upto 3.0 Ton splitcassette type AC. | Nos | 3333.75 | 3333.75 | 12.0 | False | None | None | False | None | False | 40005.0 | 0 |
2928543 | 96520 | None | RGU1265 | Supplying and installation of insulated refrigerant copper tubing of 58inches and 38inches with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube. Split | Rmtr | 1626.45 | 1626.45 | 144.0 | False | None | None | False | None | False | 234208.8 | 0 |
2928544 | 96520 | None | RGU1266 | Supply, installation of 58inches and 78inches Hard drawn refrigerant pipe and insulation suitable for 11.0 TR duct able split Air Conditioner. | Rmtr | 2345.7 | 2345.7 | 60.0 | False | None | None | False | None | False | 140742.0 | 0 |
2928545 | 96520 | None | RGU1267 | Supply, fabrication and installation of GI Ducting Along with flanges, supports and all fixing materials.24 Gauge | Sqm | 1901.55 | 1901.55 | 3225.0 | False | None | None | False | None | False | 6132498.75 | 0 |
2928546 | 96520 | None | RGU1268 | Supply, fabrication and installation of GI Ducting Along with flanges, supports and all fixing materials.22 Gauge | Sqm | 2227.05 | 2227.05 | 35.0 | False | None | None | False | None | False | 77946.75 | 0 |
2928547 | 96520 | None | RGU1269 | Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts. | Sqm | 1250.55 | 1250.55 | 3035.0 | False | None | None | False | None | False | 3795419.25 | 0 |
2928548 | 96520 | None | RGU1270 | Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories. | Nos | 4792.2 | 4792.2 | 14.0 | False | None | None | False | None | False | 67090.8 | 0 |
2928549 | 96520 | None | RGU1271 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply and return air.Aluminium Diffusers | Nos | 5331.9 | 5331.9 | 600.0 | False | None | None | False | None | False | 3199140.0 | 0 |
2928550 | 96520 | None | RGU1272 | Collar Dampers | Nos | 2755.2 | 2755.2 | 300.0 | False | None | None | False | None | False | 826560.0 | 0 |
2928551 | 96520 | None | RGU1273 | GI Mixing Box | Nos | 6588.75 | 6588.75 | 300.0 | False | None | None | False | None | False | 1976625.0 | 0 |
2928552 | 96520 | None | RGU1274 | Flexible Duct Per Mtr | Nos | 1776.6 | 1776.6 | 300.0 | False | None | None | False | None | False | 532980.0 | 0 |
2928553 | 96520 | None | RGU1275 | Supply and fixing of powder coated extruded aluminium grill suitable for supplyreturn air including all fixing hardware etc.,. Complete.4inches Extruded aluminium grille with 15 deg to 30 deg louvers. | Rmtr | 1545.6 | 1545.6 | 10.0 | False | None | None | False | None | False | 15456.0 | 0 |
2928554 | 96520 | None | RGU1276 | Supply and fixing of powder coated extruded aluminium grill suitable for supplyreturn air including all fixing hardware etc.,. Complete.6inches Extruded aluminium grille with 15 deg to 30 deg louvers. | Rmtr | 1787.1 | 1787.1 | 60.0 | False | None | None | False | None | False | 107226.0 | 0 |
2928555 | 96520 | None | RGU1277 | Supplying push button operated direct online starter with anantiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for230440 V 13 phase motor upto 5 HP. | Nos | 2023.35 | 2023.35 | 12.0 | False | None | None | False | None | False | 24280.2 | 0 |
2928556 | 96520 | None | RGU1278 | Supply, Installation, Testing and Commissioning of Air cooled Modular type Top Discharge VRVVRF Outdoor units with Inverter Driven Digital scroll singlemulti Compressor, special precoated Hydrophlic blue aluminium fines, panel, corrosion resistant and hydrophillic treatment coated condenser, variable speed based condenser fan, electrical and microprocessor panel with controls, isolating valves and etc. The VRVVRF Outdoor units should have BMS compatible with BACnet IP.The outdoor units system capable of cooling application as per individual or season requirement suitable for operation on 415 V, 3 Phase, 50 Hz AC electric supply. The outdoor units shall have cooling mode, consisting of one multiple outdoor unit with single circuit of refrigerant piping and multiple indoor units of various types. Each indoor unit should have capability to cool as per seasonal weather changes. Outdoor unit including full charging of R410a134a Chlorofluorocarbons CFC environmentally free refrigerant.Quoted unit should be single out door module and above 14.0 HP VRVVRF units to have multiple compressors. Combination of high wall, cassette, fancoil, ducted type indoor units , to have capability to cool independently for the requirements of the rooms. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing, cabling, control wiring, interlocking and all the necessary accessories for proper functioning of the units having following capacities.Proposed system to have ISEER of minimum 5.7 at variable ambient and the COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. and the ODU Unit should have ultra precise 0.1 Hz control over compressor rotation speed. Sound pressure level of each out door unit shall not be more than 63 dBA measured horizontally 1.0 m away and 1.5 meter above ground at at the standard condition. Condensing unit should selected and operated under the wider range of outdoor ambient temperature from 5degree C to 52degree C.Out door unit to have ESP of minimum 60 Pa for effective air circulation and heat transfer.The compressor shall be of highly efficient hermetic scroll type and equipped with inverter control capable of changing the speed in accordance to the cooling load requirement.out door units outdoors units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint. The VRFVRV outdoor units should selected for Ambient condition of Gulbarga.34 HP 16 +18 | Nos | 760000.0 | 760000.0 | 1.0 | False | None | None | False | None | False | 760000.0 | 0 |
2928557 | 96520 | None | RGU1279 | Supply, Installation, Testing and Commissioning of Air cooled Modular type Top Discharge VRVVRF Outdoor units with Inverter Driven Digital scroll singlemulti Compressor, special precoated Hydrophlic blue aluminium fines, panel, corrosion resistant and hydrophillic treatment coated condenser, variable speed based condenser fan, electrical and microprocessor panel with controls, isolating valves and etc. The VRVVRF Outdoor units should have BMS compatible with BACnet IP.The outdoor units system capable of cooling application as per individual or season requirement suitable for operation on 415 V, 3 Phase, 50 Hz AC electric supply. The outdoor units shall have cooling mode, consisting of one multiple outdoor unit with single circuit of refrigerant piping and multiple indoor units of various types. Each indoor unit should have capability to cool as per seasonal weather changes. Outdoor unit including full charging of R410a134a Chlorofluorocarbons CFC environmentally free refrigerant.Quoted unit should be single out door module and above 14.0 HP VRVVRF units to have multiple compressors. Combination of high wall, cassette, fancoil, ducted type indoor units , to have capability to cool independently for the requirements of the rooms. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing, cabling, control wiring, interlocking and all the necessary accessories for proper functioning of the units having following capacities.Proposed system to have ISEER of minimum 5.7 at variable ambient and the COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. and the ODU Unit should have ultra precise 0.1 Hz control over compressor rotation speed. Sound pressure level of each out door unit shall not be more than 63 dBA measured horizontally 1.0 m away and 1.5 meter above ground at at the standard condition. Condensing unit should selected and operated under the wider range of outdoor ambient temperature from 5degree C to 52degree C.Out door unit to have ESP of minimum 60 Pa for effective air circulation and heat transfer.The compressor shall be of highly efficient hermetic scroll type and equipped with inverter control capable of changing the speed in accordance to the cooling load requirement.out door units outdoors units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint. The VRFVRV outdoor units should selected for Ambient condition of Gulbarga.38 HP 18 +20 | Nos | 840000.0 | 840000.0 | 1.0 | False | None | None | False | None | False | 840000.0 | 0 |
2928558 | 96520 | None | RGU1280 | Supply, Installation, Testing and Commissioning of Air cooled Modular type Top Discharge VRVVRF Outdoor units with Inverter Driven Digital scroll singlemulti Compressor, special precoated Hydrophlic blue aluminium fines, panel, corrosion resistant and hydrophillic treatment coated condenser, variable speed based condenser fan, electrical and microprocessor panel with controls, isolating valves and etc. The VRVVRF Outdoor units should have BMS compatible with BACnet IP.The outdoor units system capable of cooling application as per individual or season requirement suitable for operation on 415 V, 3 Phase, 50 Hz AC electric supply. The outdoor units shall have cooling mode, consisting of one multiple outdoor unit with single circuit of refrigerant piping and multiple indoor units of various types. Each indoor unit should have capability to cool as per seasonal weather changes. Outdoor unit including full charging of R410a134a Chlorofluorocarbons CFC environmentally free refrigerant.Quoted unit should be single out door module and above 14.0 HP VRVVRF units to have multiple compressors. Combination of high wall, cassette, fancoil, ducted type indoor units , to have capability to cool independently for the requirements of the rooms. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing, cabling, control wiring, interlocking and all the necessary accessories for proper functioning of the units having following capacities.Proposed system to have ISEER of minimum 5.7 at variable ambient and the COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. and the ODU Unit should have ultra precise 0.1 Hz control over compressor rotation speed. Sound pressure level of each out door unit shall not be more than 63 dBA measured horizontally 1.0 m away and 1.5 meter above ground at at the standard condition. Condensing unit should selected and operated under the wider range of outdoor ambient temperature from 5degree C to 52degree C.Out door unit to have ESP of minimum 60 Pa for effective air circulation and heat transfer.The compressor shall be of highly efficient hermetic scroll type and equipped with inverter control capable of changing the speed in accordance to the cooling load requirement.out door units outdoors units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint. The VRFVRV outdoor units should selected for Ambient condition of Gulbarga.40 HP 20 +20 | Nos | 870000.0 | 870000.0 | 1.0 | False | None | None | False | None | False | 870000.0 | 0 |
2928559 | 96520 | None | RGU1281 | Supply, Installation, Testing and Commissioning of Air cooled Modular type Top Discharge VRVVRF Outdoor units with Inverter Driven Digital scroll singlemulti Compressor, special precoated Hydrophlic blue aluminium fines, panel, corrosion resistant and hydrophillic treatment coated condenser, variable speed based condenser fan, electrical and microprocessor panel with controls, isolating valves and etc. The VRVVRF Outdoor units should have BMS compatible with BACnet IP.The outdoor units system capable of cooling application as per individual or season requirement suitable for operation on 415 V, 3 Phase, 50 Hz AC electric supply. The outdoor units shall have cooling mode, consisting of one multiple outdoor unit with single circuit of refrigerant piping and multiple indoor units of various types. Each indoor unit should have capability to cool as per seasonal weather changes. Outdoor unit including full charging of R410a134a Chlorofluorocarbons CFC environmentally free refrigerant.Quoted unit should be single out door module and above 14.0 HP VRVVRF units to have multiple compressors. Combination of high wall, cassette, fancoil, ducted type indoor units , to have capability to cool independently for the requirements of the rooms. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing, cabling, control wiring, interlocking and all the necessary accessories for proper functioning of the units having following capacities.Proposed system to have ISEER of minimum 5.7 at variable ambient and the COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. and the ODU Unit should have ultra precise 0.1 Hz control over compressor rotation speed. Sound pressure level of each out door unit shall not be more than 63 dBA measured horizontally 1.0 m away and 1.5 meter above ground at at the standard condition. Condensing unit should selected and operated under the wider range of outdoor ambient temperature from 5degree C to 52degree C.Out door unit to have ESP of minimum 60 Pa for effective air circulation and heat transfer.The compressor shall be of highly efficient hermetic scroll type and equipped with inverter control capable of changing the speed in accordance to the cooling load requirement.out door units outdoors units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint. The VRFVRV outdoor units should selected for Ambient condition of Gulbarga.48 HP 16 +16 +16 | Nos | 1085000.0 | 1085000.0 | 1.0 | False | None | None | False | None | False | 1085000.0 | 0 |
2928560 | 96520 | None | RGU1282 | Supply, Installation, Testing and Commissioning of Air cooled Modular type Top Discharge VRVVRF Outdoor units with Inverter Driven Digital scroll singlemulti Compressor, special precoated Hydrophlic blue aluminium fines, panel, corrosion resistant and hydrophillic treatment coated condenser, variable speed based condenser fan, electrical and microprocessor panel with controls, isolating valves and etc. The VRVVRF Outdoor units should have BMS compatible with BACnet IP.The outdoor units system capable of cooling application as per individual or season requirement suitable for operation on 415 V, 3 Phase, 50 Hz AC electric supply. The outdoor units shall have cooling mode, consisting of one multiple outdoor unit with single circuit of refrigerant piping and multiple indoor units of various types. Each indoor unit should have capability to cool as per seasonal weather changes. Outdoor unit including full charging of R410a134a Chlorofluorocarbons CFC environmentally free refrigerant.Quoted unit should be single out door module and above 14.0 HP VRVVRF units to have multiple compressors. Combination of high wall, cassette, fancoil, ducted type indoor units , to have capability to cool independently for the requirements of the rooms. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing, cabling, control wiring, interlocking and all the necessary accessories for proper functioning of the units having following capacities.Proposed system to have ISEER of minimum 5.7 at variable ambient and the COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. and the ODU Unit should have ultra precise 0.1 Hz control over compressor rotation speed. Sound pressure level of each out door unit shall not be more than 63 dBA measured horizontally 1.0 m away and 1.5 meter above ground at at the standard condition. Condensing unit should selected and operated under the wider range of outdoor ambient temperature from 5degree C to 52degree C.Out door unit to have ESP of minimum 60 Pa for effective air circulation and heat transfer.The compressor shall be of highly efficient hermetic scroll type and equipped with inverter control capable of changing the speed in accordance to the cooling load requirement.out door units outdoors units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint. The VRFVRV outdoor units should selected for Ambient condition of Gulbarga.60 HP 20+20 +20 | Nos | 1300000.0 | 1300000.0 | 3.0 | False | None | None | False | None | False | 3900000.0 | 0 |
2928561 | 96520 | None | RGU1283 | Supply, installation, testing and commissioning of Air cooled VRVVRF outdoor units InterfaceCommunicate to with Third party Building AutomationBMS System. Bacnet integrator for 64 Indoor unit Note : Communication should be BACnet IP communication and necessary cabling works.and Indoor units and out door units naming is done as per the client requirement and required interface to be done by HVAC vendor to IBMS vendor. | Nos | 150000.0 | 150000.0 | 1.0 | False | None | None | False | None | False | 150000.0 | 0 |
2928562 | 96520 | None | RGU1284 | Supply, Installing, testing and commissioning of Centralized Intelligent inchesIinches Touch Manager Controller with LCD display server for entire circuits with relay interface and necessary hardwaresoftware. The scope should also inclusive of necessary monitoring and controling with communication cabling With PVC conduit from VRFVRV ODU to Centralized Intelligent inchesIinches Touch Manager Controller with Self diagnostics and zonal temperature measurement facilities and yearly schedule with adaptor to control and monitor all indoor units and generate the tenant billing.Location : Maintance room. Room Location will confirm by clientoperator | Nos | 150000.0 | 150000.0 | 2.0 | False | None | None | False | None | False | 300000.0 | 0 |
2928563 | 96520 | None | RGU1285 | Supply Installation, Testing and Commissioning of VRVVRFMedium StaticCeiling Suspended ductable Units with multi 3 step speed controller with canvass connection. These unit shall be includeing of prefilter, fan section, coil section etc. The fan shall be Aerodynamically designed diffuser turbo fan type, low noise, electronic expansion valve, compact cooling coil with in built Drain pump with sound absorbing insulation material, washable Prefilter and thermal protector fan motor with carded remote controller and remote controller shall house a thermostat sensor for better room temperature control,should be sleek and self diagnostic type. Degree air distribution, The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit shall have, fresh air intake provision, low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc...Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kgcm2.3.20 TR 1342 CFM 15mm TSP | Nos | 53000.0 | 53000.0 | 2.0 | False | None | None | False | None | False | 106000.0 | 0 |
2928564 | 96520 | None | RGU1286 | Supply Installation, Testing and Commissioning of VRVVRFMedium StaticCeiling Suspended ductable Units with multi 3 step speed controller with canvass connection. These unit shall be includeing of prefilter, fan section, coil section etc. The fan shall be Aerodynamically designed diffuser turbo fan type, low noise, electronic expansion valve, compact cooling coil with in built Drain pump with sound absorbing insulation material, washable Prefilter and thermal protector fan motor with carded remote controller and remote controller shall house a thermostat sensor for better room temperature control,should be sleek and self diagnostic type. Degree air distribution, The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit shall have, fresh air intake provision, low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc...Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kgcm2.4.00 TR 1350 CFM 15mm TSP | Nos | 56000.0 | 56000.0 | 43.0 | False | None | None | False | None | False | 2408000.0 | 0 |
2928565 | 96520 | None | RGU1287 | Supply Installation, Testing and Commissioning of VRVVRFMedium StaticCeiling Suspended ductable Units with multi 3 step speed controller with canvass connection. These unit shall be includeing of prefilter, fan section, coil section etc. The fan shall be Aerodynamically designed diffuser turbo fan type, low noise, electronic expansion valve, compact cooling coil with in built Drain pump with sound absorbing insulation material, washable Prefilter and thermal protector fan motor with carded remote controller and remote controller shall house a thermostat sensor for better room temperature control,should be sleek and self diagnostic type. Degree air distribution, The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit shall have, fresh air intake provision, low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc...Statically and dynamically balanced to ensure lowest noise. The cooling coil shall be made of seamless copper tube. The tube shall be hydraulically or mechanically expanded and tested for 21 Kgcm2.4.60 TR 1400 CFM 15mm TSP | Nos | 62000.0 | 62000.0 | 2.0 | False | None | None | False | None | False | 124000.0 | 0 |
2928566 | 96520 | None | RGU1288 | Supply Installation, Testing and Commissioning of Ceiling mounted VRVVRF4 Way Cassette Units with Panel 950x950 with multi 3 step speed controller Ceiling mounted unit with multi speed fan, cooling coil, cordless remote sensor, thermostat, washable type Prefilter, auto swing in both directions, low noise fan, complete with refrigerant valve set, electronic expansion valve. The fan shall be Aerodynamically designed diffuser turbo fan type. 360 degree air distribution. The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit should haveing with In Built High Lift drain pump with fresh air intake provision. low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc. The units shall be suitable for input power supply of 1phase, 230volts, 50hz. 2.60 TR 750 CFM | Nos | 42000.0 | 42000.0 | 23.0 | False | None | None | False | None | False | 966000.0 | 0 |
2928567 | 96520 | None | RGU1289 | Supply Installation, Testing and Commissioning of Ceiling mounted VRVVRF4 Way Cassette Units with Panel 950x950 with multi 3 step speed controller Ceiling mounted unit with multi speed fan, cooling coil, cordless remote sensor, thermostat, washable type Prefilter, auto swing in both directions, low noise fan, complete with refrigerant valve set, electronic expansion valve. The fan shall be Aerodynamically designed diffuser turbo fan type. 360 degree air distribution. The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit should haveing with In Built High Lift drain pump with fresh air intake provision. low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc. The units shall be suitable for input power supply of 1phase, 230volts, 50hz. 3.20 TR 950 CFM | Nos | 44000.0 | 44000.0 | 13.0 | False | None | None | False | None | False | 572000.0 | 0 |
2928568 | 96520 | None | RGU1290 | Supply Installation, Testing and Commissioning of Ceiling mounted VRVVRF4 Way Cassette Units with Panel 950x950 with multi 3 step speed controller Ceiling mounted unit with multi speed fan, cooling coil, cordless remote sensor, thermostat, washable type Prefilter, auto swing in both directions, low noise fan, complete with refrigerant valve set, electronic expansion valve. The fan shall be Aerodynamically designed diffuser turbo fan type. 360 degree air distribution. The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit should haveing with In Built High Lift drain pump with fresh air intake provision. low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc. The units shall be suitable for input power supply of 1phase, 230volts, 50hz. 4.00 TR 1050 CFM | Nos | 49500.0 | 49500.0 | 2.0 | False | None | None | False | None | False | 99000.0 | 0 |
2928569 | 96520 | None | RGU1291 | Supply Installation, Testing and Commissioning of Ceiling mounted VRVVRF4 Way Cassette Units with Panel 600x600 with multi 3 step speed controller Ceiling mounted unit with multi speed fan, cooling coil, cordless remote sensor, thermostat, washable type Prefilter, auto swing in both directions, low noise fan, complete with refrigerant valve set, electronic expansion valve. The fan shall be Aerodynamically designed diffuser turbo fan type. 360 degree air distribution. The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit should haveing with In Built High Lift drain pump with fresh air intake provision. low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc. The units shall be suitable for input power supply of 1phase, 230volts, 50hz. 1.00 TR 450 CFM | Nos | 36000.0 | 36000.0 | 18.0 | False | None | None | False | None | False | 648000.0 | 0 |
2928570 | 96520 | None | RGU1292 | Supply Installation, Testing and Commissioning of Ceiling mounted VRVVRF4 Way Cassette Units with Panel 600x600 with multi 3 step speed controller Ceiling mounted unit with multi speed fan, cooling coil, cordless remote sensor, thermostat, washable type Prefilter, auto swing in both directions, low noise fan, complete with refrigerant valve set, electronic expansion valve. The fan shall be Aerodynamically designed diffuser turbo fan type. 360 degree air distribution. The cooling coil shall be of seamless copper tubes and shall have continuous aluminium fins. Unit shall have filter cleanable type of resin net fixed to an integrally molded plastic frame. Unit should haveing with In Built High Lift drain pump with fresh air intake provision. low gas level detection system. Unit shall have an electronic expansion valve which control refrigerant flow rate in respond to load variations of room. units shall be suitable for single phase power supply, etc. The units shall be suitable for input power supply of 1phase, 230volts, 50hz. 1.30 TR 500 CFM | Nos | 37000.0 | 37000.0 | 4.0 | False | None | None | False | None | False | 148000.0 | 0 |
2928571 | 96520 | None | RGU1293 | Supply Installation, Testing and Commissioning of VRVVRFHIWall Units with multi 3 step speed controllerWall mounted type Indoor unit with multi speed fan, cooling coil, cordless remote sensor, thermostat, washable type Prefilter, auto swing in both directions, low noise fan, complete with refrigerant valve set, electronic expansion valve.units shall be suitable for single phase power supply, etc.2.00 TR 550 CFM | Nos | 43000.0 | 43000.0 | 12.0 | False | None | None | False | None | False | 516000.0 | 0 |
2928572 | 96520 | None | RGU1294 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.14inches 6.35 mm X 21 Swg 0.8 mm Soft drawn Insulation = 13mm thick | Rmtr | 1200.0 | 1200.0 | 110.0 | False | None | None | False | None | False | 132000.0 | 0 |
2928573 | 96520 | None | RGU1295 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.38inches 9.52 mm X 21 Swg 0.8mm Soft drawn Insulation = 13mm thick | Rmtr | 1250.0 | 1250.0 | 785.9 | False | None | None | False | None | False | 982375.0 | 0 |
2928574 | 96520 | None | RGU1296 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.12inches 12.7 mm X 21 Swg 0.8 mm Soft drawn Insulation = 13mm thick | Rmtr | 1400.0 | 1400.0 | 222.85 | False | None | None | False | None | False | 311990.0 | 0 |
2928575 | 96520 | None | RGU1297 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.58inches 15.9 mm X 19 Swg 1 mm Soft drawn Insulation = 13mm thick | Rmtr | 1550.0 | 1550.0 | 770.8 | False | None | None | False | None | False | 1194740.0 | 0 |
2928576 | 96520 | None | RGU1298 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.34inches 19.05 mm X 19 Swg 1 mm Hard drawn Insulation = 13mm thick | Rmtr | 1650.0 | 1650.0 | 456.9 | False | None | None | False | None | False | 753885.0 | 0 |
2928577 | 96520 | None | RGU1299 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.78inches 22.2 mm X 19 Swg 1 mm Hard drawn Insulation = 19mm thick | Rmtr | 1750.0 | 1750.0 | 157.9 | False | None | None | False | None | False | 276325.0 | 0 |
2928578 | 96520 | None | RGU1300 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.1.0inches 25.4 mm X 19 Swg 1 mm Hard drawn Insulation = 19mm thick | Rmtr | 1850.0 | 1850.0 | 35.2 | False | None | None | False | None | False | 65120.0 | 0 |
2928579 | 96520 | None | RGU1301 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.1 18inches 28.6 mm X 19 Swg 1 mm Hard drawn Insulation = 19mm thick | Rmtr | 1950.0 | 1950.0 | 123.35 | False | None | None | False | None | False | 240532.5 | 0 |
2928580 | 96520 | None | RGU1302 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.1 14inches 31.8 mm X 18.5 Swg 1.1 mm Hard drawn Insulation = 19mm thick | Rmtr | 2050.0 | 2050.0 | 117.45 | False | None | None | False | None | False | 240772.5 | 0 |
2928581 | 96520 | None | RGU1303 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.1 38inches 34.9 mm X 18 Swg 1.2 mm Hard drawn Insulation = 19mm thick | Rmtr | 2150.0 | 2150.0 | 15.4 | False | None | None | False | None | False | 33110.0 | 0 |
2928582 | 96520 | None | RGU1304 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.1 12inches 38.1 mm X 17.5 Swg 1.3 mm Hard drawn Insulation = 19mm thick | Rmtr | 2250.0 | 2250.0 | 75.7 | False | None | None | False | None | False | 170325.0 | 0 |
2928583 | 96520 | None | RGU1305 | Supply, installation, testing and commissioning of Interconnecting Soft drawn Hard drawn Refrigerant copper Piping with insulation with UV protection coating. Note: a To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.b UV protection coating on existing copper pipes with insulation shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipeswork duly insulated with 13mm and 19mm thick elastomeric nitrile rubber type tubular insulation between VRVVRF Type indoor and outdoor units.Note : c Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.d Refrigerant copper Piping quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.e Actual measurement of Refrigerant copper Piping quantity Rmt should be taken as per site condition only.1 58inches 41.3 mm X 17 Swg 1.43 mm Hard drawn Insulation = 19mm thick | Rmtr | 2400.0 | 2400.0 | 221.35 | False | None | None | False | None | False | 531240.0 | 0 |
2928584 | 96520 | None | RGU1306 | Supply, installation, testing and commissioning of high pressure grade required copper connection Y or TRefnet joints for liquid and suction line complete erected on wallceiling with supportsraceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRVVRF air conditioning system. | Nos | 5000.0 | 5000.0 | 130.0 | False | None | None | False | None | False | 650000.0 | 0 |
2928585 | 96520 | None | RGU1307 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal CeilingFloor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI outer skin shall be pre coated and 0.6 Plain GI inner skin double skin 23 2 mm insulated with CFC free polyurethane foam PUF panels of 40 Kgcum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans Efficiency with 75percent AMCA Certified to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts and Belt guard, PreFilter of MERV 8 EU4 90percent down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make Nicotra Kruger.The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels and threaded rods.The Motor shall be of TEFC, IP55 protected, IE3, Class F insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately Cost excluded for the same .Costing is inclusive of Factory fabricated noncloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.1,000 CFM 40 mm TSP 0.75 kW | Nos | 30000.0 | 30000.0 | 3.0 | False | None | None | False | None | False | 90000.0 | 0 |
2928586 | 96520 | None | RGU1308 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal CeilingFloor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI outer skin shall be pre coated and 0.6 Plain GI inner skin double skin 23 2 mm insulated with CFC free polyurethane foam PUF panels of 40 Kgcum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans Efficiency with 75percent AMCA Certified to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts and Belt guard, PreFilter of MERV 8 EU4 90percent down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make Nicotra Kruger.The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels and threaded rods.The Motor shall be of TEFC, IP55 protected, IE3, Class F insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately Cost excluded for the same .Costing is inclusive of Factory fabricated noncloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.1,500 CFM 40 mm TSP 0.75 kW | Nos | 37500.0 | 37500.0 | 3.0 | False | None | None | False | None | False | 112500.0 | 0 |
2928587 | 96520 | None | RGU1309 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal CeilingFloor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI outer skin shall be pre coated and 0.6 Plain GI inner skin double skin 23 2 mm insulated with CFC free polyurethane foam PUF panels of 40 Kgcum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans Efficiency with 75percent AMCA Certified to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts and Belt guard, PreFilter of MERV 8 EU4 90percent down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make Nicotra Kruger.The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels and threaded rods.The Motor shall be of TEFC, IP55 protected, IE3, Class F insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately Cost excluded for the same .Costing is inclusive of Factory fabricated noncloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.2,000 CFM 40 mm TSP 1.1 kW | Nos | 60000.0 | 60000.0 | 3.0 | False | None | None | False | None | False | 180000.0 | 0 |
2928588 | 96520 | None | RGU1310 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal CeilingFloor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI outer skin shall be pre coated and 0.6 Plain GI inner skin double skin 23 2 mm insulated with CFC free polyurethane foam PUF panels of 40 Kgcum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans Efficiency with 75percent AMCA Certified to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts and Belt guard, PreFilter of MERV 8 EU4 90percent down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make Nicotra Kruger.The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels and threaded rods.The Motor shall be of TEFC, IP55 protected, IE3, Class F insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately Cost excluded for the same .Costing is inclusive of Factory fabricated noncloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.2,500 CFM 40 mm TSP 1.1 kW | Nos | 75000.0 | 75000.0 | 3.0 | False | None | None | False | None | False | 225000.0 | 0 |
2928589 | 96520 | None | RGU1311 | Supply, Installation, Testing and Commissioning of Rectangular Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, noncanvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.Note : Rectangular Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.Note: Costing is inclusive of Factory fabricated noncloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between FreshExhaut air units outlet flange and the connected plenum or ducts.150 CFM 20mm TSP. | Nos | 9000.0 | 9000.0 | 5.0 | False | None | None | False | None | False | 45000.0 | 0 |
2928590 | 96520 | None | RGU1312 | Supply, Installation, Testing and Commissioning of Rectangular Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, noncanvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.Note : Rectangular Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.Note: Costing is inclusive of Factory fabricated noncloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between FreshExhaut air units outlet flange and the connected plenum or ducts.300 CFM 20mm TSP . | Nos | 10000.0 | 10000.0 | 5.0 | False | None | None | False | None | False | 50000.0 | 0 |
2928591 | 96520 | None | RGU1313 | Supply, Installation, Testing and Commissioning of Galvanized ductClass VIII with zinc coating of 120 gm Sqmt surface area as per IS277. With TDFTDC Flange system with factory fabricated Box section with neoprene rubber gaskets of thickness to match the dimensions of the ducts shall be used for connecting two ducts.Duct construction and installation shall be in accordance with SMACNA codes and Standards and all ducts testing pressure should be 500 Pascal. pa .All ducting shall be of factory fabricated completely finished and transported to site in a boxed form including the duct flange and the VAV transition pieces, grille slot diffusers plenum boxes, Z pieces and etc.. The Duct shall be supported with GI steel Rods and MS angle Supports at regular minimum 2500mm intervals.Ducts should be factory fabricated and Transportation should be in box section only to site. in site the duct needs to be stored in proper manner and covered with polythene sheets to avoid dust accumulation.G.I. Sheet Make Tata Sail Jindal Vizag Steel. Ducts sizes from and above 1200mm width should have Tie rods placed as per the standards with gasket and sealant to avoid the duct Bulging and Bulge out. These ducting quintettes are including of slot diffusers plenum boxes with necessary threaded rods for supporting and anchor fasten. Vendor need to consider while quoting.All accessories like sealant, vanes, flanges, suspension rods , anchor bolts, GI bolts and nuts, canvas connections and splitter dampers etc.,. Costing is inclusive of MS angle Supports at regular intervals, threaded rod supports, angle flanges, anchor fastners, hot dipped galvanized bolts and nuts. Scaffolding arrangements to install the ducts and air terminals etc., Costing is inclusive of Scaffolding arrangements to install the ducts and air terminals.Costing is inclusive of Opening and closing for all the duct entries in civil gypsum any type of partition shall be under scope of HVAC vendor. Duct routing diagram can be checked in drawing prior for quoting.ressure testing of sheet metal ducts with necessary components like semirigid flexible ducts, fans and the measuring kit. Pressure testing shall be carried out for complete air distribution system excluding flexible ducts, diffuser box, diffusers and grilles. Pressure testing shall be carried out prior to thermal insulation and as per SMACNA standards and approval shall be obtained from PMC and consultants.20 Gauge 1.00mm Thick 1201mm 2100mm | Sqm | 2200.0 | 2200.0 | 20.0 | False | None | None | False | None | False | 44000.0 | 0 |
2928592 | 96520 | None | RGU1314 | Supply, Installation, Testing and Commissioning of Open cell inchesClass1inches Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL181 and E2180 , Density 140180Kg m3, UL94 approved HBF, HF 1 and HF 2 in accordance to UL 94,1996. Thermal conductivity 0.047 W MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 107105 section 12.7 . Moisture resistantjoining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier.Use Low Voc Adhesive. Adhesive VOC level as per LEED requirement Note if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.15mm Thick | Sqm | 1100.0 | 1100.0 | 400.0 | False | None | None | False | None | False | 440000.0 | 0 |
2928593 | 96520 | None | RGU1315 | Supply, Installation, Testing and Commissioning of Open cell inchesClass1inches Nitrile rubber Insulation for Wall Acoustics insulation with PreFabricated Panels of 600 x 600 mm or size suiting siteAHU room conditions with GI frame work using 1mm thick formed U shaped channel with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL181 and E2180 , Density 140180Kg m3, UL94 approved HBF, HF 1 and HF 2 in accordance to UL 94,1996. Thermal conductivity 0.047 W MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 107105 section 12.7 . Use Low Voc Adhesive. Adhesive VOC level as per LEED requirement Note if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.25mm Thick | Sqm | 1500.0 | 1500.0 | 100.0 | False | None | None | False | None | False | 150000.0 | 0 |
2928594 | 96520 | None | RGU1316 | Supply, Installation, Testing and Commissioning of Closed cell inchesClassOinches Nitrile rubber Insulation with Factroy Laminated Alufoil with Ultrafresh Antimicrobial protection with both side skinsmooth surface, As per ASTM G21, ASTM G22, UL181 and E2180. Class O IMO A 653 16 , FM Global, UL 94 and EPA approved,with Density 4060kg m3. Temperature of 50 to 116 Deg C and As per EN12667 DIN 52612 . Thermal conductivity of 0.036 W m K at 0 deg C. Water vapour permeability as per EN12086 DIN 52615 , Moisture Resistance Factor = 7000. Aluminum foil tape of 75mm width should be used to seal the joints with self adhesive tape Black Cotton Tape not acceptable . Use Low Voc Adhesive. Adhesive VOC level as per LEED requirement Material shall be FM approved and preferred color shall be Black.Note if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.Note: Costing is inclusive of necessary support like cup and washer with scaffolding arrangements to install the underdeck insulation.25mm Thick Under Deck Insulation | Sqm | 900.0 | 900.0 | 1550.0 | False | None | None | False | None | False | 1395000.0 | 0 |
2928595 | 96520 | None | RGU1317 | Supply, Installation, Testing and Commissioning of Factory fabricated powder coated Double skin plenum. Outer skin constructed with not less than 0.63mm thick GI sheet and the inner sheet shall be of not less than 0.63mm GI plain sheet., with 25mm thick sandwiched RPUF CFC free insulation of density not less than 40kg cum. And with necessary High grade Extruded Aluminum cross supports for rigidity and cutouts for duct and AHU connections. Note: a The Plenum shall be provided with as Access Door. Size are not less then 800mmx600mm b These plenum is inside the AHU Rooms should be supported with special acoustic hangers to avoid transmission of vibaration from AHU Room to adjacent sensitive areas.c Color of the Plenum should match the color of AHU and CSU installed at site. | Sqm | 5000.0 | 5000.0 | 25.0 | False | None | None | False | None | False | 125000.0 | 0 |
2928596 | 96520 | None | RGU1318 | Supply, Installation, Testing and Commissioning of Fire damper with opposed blade Fusible link type . Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the bladeLeaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link and spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C. Area calculation : L x B | Sqm | 13000.0 | 13000.0 | 5.0 | False | None | None | False | None | False | 65000.0 | 0 |
2928597 | 96520 | None | RGU1319 | Supply, Installation, Testing and Commissioning of Quadrant type Volume controle Damper VCD . The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the bladeLeaf with 1.6mm thick GSS and with necessary flanges for connection etc., Area calculation : L x B | Sqm | 8000.0 | 8000.0 | 15.0 | False | None | None | False | None | False | 120000.0 | 0 |
2928598 | 96520 | None | RGU1320 | Supply, Installation, Testing and Commissioning of Back draft damper BDD . The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the bladeLeaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications. Area calculation : L x B | Sqm | 9000.0 | 9000.0 | 2.0 | False | None | None | False | None | False | 18000.0 | 0 |
2928599 | 96520 | None | RGU1321 | Supply, Installation, Testing and Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange.250 dia | Nos | 2000.0 | 2000.0 | 300.0 | False | None | None | False | None | False | 600000.0 | 0 |
2928600 | 96520 | None | RGU1322 | Supply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers. Used in supplay air | Sqm | 6500.0 | 6500.0 | 5.0 | False | None | None | False | None | False | 32500.0 | 0 |
2928601 | 96520 | None | RGU1323 | Supply, Installation, Testing and Commissioning of Extruded Aluminum powder coated Exhaust air Disc valvesgrille without volume control dampers for Pantry. a Note: Colour shall be as per the False ceiling or Architect intent.150 mm Dia | Nos | 1250.0 | 1250.0 | 10.0 | False | None | None | False | None | False | 12500.0 | 0 |
2928602 | 96520 | None | RGU1324 | Supply, Installation, Testing and Commissioning of Extruded Aluminum powder coated Exhaust air Disc valvesgrille without volume control dampers for Pantry. a Note: Colour shall be as per the False ceiling or Architect intent.200 mm Dia | Nos | 1500.0 | 1500.0 | 10.0 | False | None | None | False | None | False | 15000.0 | 0 |
2928603 | 96520 | None | RGU1325 | Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air Exhaust air louvers with slimline blade 3 mm nominal thickness grille height 16 mm, blade pitch 12.5 mm and blade angle 015 degree deflection without damper and with end flanges.Note: Colour shall be as per the False ceiling or Architect intent. | Sqm | 9000.0 | 9000.0 | 5.0 | False | None | None | False | None | False | 45000.0 | 0 |
2928604 | 96520 | None | RGU1326 | Supply, Installation, Testing and Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Yconnections and flexible tubing for all indoor units to the nearest drain points toilet drain pantry drain HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.40 mm dia | Rmtr | 500.0 | 500.0 | 90.0 | False | None | None | False | None | False | 45000.0 | 0 |
2928605 | 96520 | None | RGU1327 | Supply, Installation, Testing and Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Yconnections and flexible tubing for all indoor units to the nearest drain points toilet drain pantry drain HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.32 mm dia | Rmtr | 450.0 | 450.0 | 660.0 | False | None | None | False | None | False | 297000.0 | 0 |
2928606 | 96520 | None | RGU1328 | Supply, Installation, Testing and Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Yconnections and flexible tubing for all indoor units to the nearest drain points toilet drain pantry drain HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.25 mm dia | Rmtr | 350.0 | 350.0 | 800.0 | False | None | None | False | None | False | 280000.0 | 0 |
2928607 | 96520 | None | RGU1329 | Supply, Installation, Testing and Commissioning of Drain Pumps for CHWVRVVRFDX Type HiWall Units and Ceiling Mounted Units.Mini Blanc Pumps External for HiWall units. Max. flow 12Lh and Head is 10Met | Nos | 7000.0 | 7000.0 | 24.0 | False | None | None | False | None | False | 168000.0 | 0 |
2928608 | 96520 | None | RGU1330 | Supply, Installation, Testing and Commissioning of Drain Pumps for CHWVRVVRFDX Type HiWall Units and Ceiling Mounted Units.Max HiFlow Above 5.0 TR CSUFCU Max. flow 550Lh and Head is 5Met | Nos | 9000.0 | 9000.0 | 2.0 | False | None | None | False | None | False | 18000.0 | 0 |
2928609 | 96520 | None | RGU1331 | Supply, installation, testing and commissioning of Electrical Power and Controle cabling for AC units, Ventilation and Pressurization fans units.Note : a Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.b Electrical Power cabling quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.c Actual measurement of Electrical Power cabling quantity Rmt should be taken as per site condition only.3.0 Core x 2.5 Sqmm For AHUCSUVentilation units units. Can be used up to 3.7 Kw 3Phase Flexible Crosslinked polyethylene XLPE insulated Armoured copper cables FRLS Control and Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. | Rmtr | 400.0 | 400.0 | 90.0 | False | None | None | False | None | False | 36000.0 | 0 |
2928610 | 96520 | None | RGU1332 | Supply, installation, testing and commissioning of Electrical Power and Controle cabling for VRV VRF Indoor and Outdoor units.Note : a Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.b Electrical Power and Controle cabling quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.c Actual measurement of Electrical Power and Controle cabling quantity Rmt should be taken as per site condition only.4 core 6 sq.mm For 8 to 10 HP flexible Crosslinked polyethylene XLPE Insulated Armoured copper cables FRLS Power cable with saddlessupports and PVC conduits to connect Ele Individual 25 Amps feedar to all VRF Outdoor units. Location near to the VRVVRF ODU units Note From main electrical panel to TPN MCBMCCB is in Electrical scope of works and TPN MCBMCCB to VRVVRF out door units power supply are in HVAC vendor scope. | Rmtr | 550.0 | 550.0 | 10.0 | False | None | None | False | None | False | 5500.0 | 0 |
2928611 | 96520 | None | RGU1333 | Supply, installation, testing and commissioning of Electrical Power and Controle cabling for VRV VRF Indoor and Outdoor units.Note : a Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.b Electrical Power and Controle cabling quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.c Actual measurement of Electrical Power and Controle cabling quantity Rmt should be taken as per site condition only.4 core 10 sq.mm For 12 to 18 HP flexible Crosslinked polyethylene XLPE Insulated Armoured copper cables FRLS Power cable with saddlessupports and PVC conduits to connect Ele Individual 32 Amps feedar to all VRF Outdoor units. Location near to the VRVVRF ODU units Note From main electrical panel to TPN MCBMCCB is in Electrical scope of works and TPN MCBMCCB to VRVVRF out door units power supply are in HVAC vendor scope. | Rmtr | 700.0 | 700.0 | 60.0 | False | None | None | False | None | False | 42000.0 | 0 |
2928612 | 96520 | None | RGU1334 | Supply, installation, testing and commissioning of Electrical Power and Controle cabling for VRV VRF Indoor and Outdoor units.Note : a Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.b Electrical Power and Controle cabling quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.c Actual measurement of Electrical Power and Controle cabling quantity Rmt should be taken as per site condition only.4 core16 sq.mm For 20 HP and 24 HP flexible Crosslinked polyethylene XLPE Insulated Armoured copper cables FRLS Power cable with saddlessupports and PVC conduits to connect Ele Individual 40 Amps feedar to all VRF Outdoor units. Location near to the VRVVRF ODU units Note From main electrical panel to TPN MCBMCCB is in Electrical scope of works and TPN MCBMCCB to VRVVRF out door units power supply are in HVAC vendor scope. | Rmtr | 800.0 | 800.0 | 60.0 | False | None | None | False | None | False | 48000.0 | 0 |
2928613 | 96520 | None | RGU1335 | Supply, installation, testing and commissioning of Electrical Power and Controle cabling for VRV VRF Indoor and Outdoor units.Note : a Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.b Electrical Power and Controle cabling quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.c Actual measurement of Electrical Power and Controle cabling quantity Rmt should be taken as per site condition only.3 core 2.5 sq.mm Flexible Crosslinked polyethylene XLPE Insulated Armoured copper cables FRLS Power cable with saddlessupports and PVC conduits to connect Ele 5 AmpsPlug top and socket feedar to all VRVVRF indoor units. | Rmtr | 300.0 | 300.0 | 118.0 | False | None | None | False | None | False | 35400.0 | 0 |
2928614 | 96520 | None | RGU1336 | Supply, installation, testing and commissioning of Electrical Power and Controle cabling for VRV VRF Indoor and Outdoor units.Note : a Costing is inclusive of necessary supports and supporting rods, saddles at 1m interval.b Electrical Power and Controle cabling quantity Rmt to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.c Actual measurement of Electrical Power and Controle cabling quantity Rmt should be taken as per site condition only.2 core 1.5 sq.mm Flexible Crosslinked polyethylene XLPE Insulated Armoured copper cables FRLS communication looping cable with saddlessupports and PVC conduits to connect VRFVRV indoor units to VRFVR Outdoor units. | Rmtr | 200.0 | 200.0 | 2164.96 | False | None | None | False | None | False | 432992.0 | 0 |
2928615 | 96520 | None | RGU1337 | Supplying, Installing testing and commissioning approved make BOOSTER PUMP . The quated price shall aslo include 1 Nos. Pressure guages fitted on suction and delivery sides of the pump. The pumps shall run on 400440V 3 ph. 50 Hz electric supply. Duty of pumps: 900 Lpm at 35.0m Head. Control panel shall be as specified in item no, 87, including cost of materials, labour, usage charges of machinery complete as per specifications. | No | 94500.0 | 94500.0 | 1.0 | False | None | None | False | None | False | 94500.0 | 0 |
2928616 | 96520 | None | RGU1338 | Supplying, installing , testing and commissioning approved make BOOSTER PUMP Panel with necessary nuts and bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineerincharge of the work | Each | 36750.0 | 36750.0 | 1.0 | False | None | None | False | None | False | 36750.0 | 0 |
2928617 | 96520 | None | RGU1339 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronzegunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13039 of following sizes as required 100mm dia | Nos | 9450.0 | 9450.0 | 5.0 | False | None | None | False | None | False | 47250.0 | 0 |
2928618 | 96520 | None | RGU1340 | Providing, installation, testing and commissioning of nonreturn valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100 mm dia | Nos | 7476.0 | 7476.0 | 2.0 | False | None | None | False | None | False | 14952.0 | 0 |
2928619 | 96520 | None | RGU1341 | Providing, installation, testing and commissioning of stainless steel Ystrainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm diaholes with stainless steel flange.100mm dia | Nos | 13009.5 | 13009.5 | 1.0 | False | None | None | False | None | False | 13009.5 | 0 |
2928620 | 96520 | None | RGU1342 | Pressure guage of 150 mm dia including Isolation Valve and forged siphon Tube including with all accssories as per IS:Spec. | Nos | 3045.0 | 3045.0 | 1.0 | False | None | None | False | None | False | 3045.0 | 0 |
2928621 | 96520 | None | RGU1343 | Providing and fixing of pressure switch in M.S. pipe line including connection etc. as required. | Nos | 2047.5 | 2047.5 | 1.0 | False | None | None | False | None | False | 2047.5 | 0 |
2928622 | 96520 | None | RGU1344 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. | Kg | 154.35 | 154.35 | 150.0 | False | None | None | False | None | False | 23152.5 | 0 |
2928623 | 96520 | None | RGU1345 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 4.0 Core 16.00 Sq.mm.Main Panel to Jockey | Km | 192614.1 | 192614.1 | 0.08 | False | None | None | False | None | False | 15409.128 | 0 |
2928624 | 96520 | None | RGU1346 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed. 3 Core x 1.5Sqmm for Pressure Switch | Mtr | 75.6 | 75.6 | 50.0 | False | None | None | False | None | False | 3780.0 | 0 |
2928625 | 96520 | None | RGU1347 | GICopper strips for grounding connections, using necessary fixingmaterials as required 25 x 3 mm GI strip | Mtr | 86.1 | 86.1 | 100.0 | False | None | None | False | None | False | 8610.0 | 0 |
2928626 | 96520 | None | RGU1348 | Supplying Installing, testing and commissioning of Gun metal AIRRELEASE VALVE SIZE OF 25mm dia including cost of materials, labour,usage charges of machinery complete as per specifications. Complete | Each | 1575.0 | 1575.0 | 2.0 | False | None | None | False | None | False | 3150.0 | 0 |
2928627 | 96520 | None | RGU1349 | Supplying Installing, testing and commissioning of Gun metal BALLVALVE SIZE OF 25mm dia including cost of materials, labour, usagecharges of machinery complete as per specifications. Complete | Nos | 1260.0 | 1260.0 | 14.0 | False | None | None | False | None | False | 17640.0 | 0 |
2928628 | 96520 | None | RGU1350 | Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41Tech pipeM.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 100 mm dia | Mtr | 2992.5 | 2992.5 | 154.0 | False | None | None | False | None | False | 460845.0 | 0 |
2928629 | 96520 | None | RGU1351 | Supply, Installation testing and commissioning of approved make heavy quantity Class 'C' confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing Using 41Tech pipeM.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. 25 mm dia | Mtr | 735.0 | 735.0 | 12.0 | False | None | None | False | None | False | 8820.0 | 0 |
2928630 | 96520 | None | RGU1352 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire brigade inlet connection of 2 nos. 63 mm dia. including cost of materials, labour, usage charges of machinery complete as per specifications | Nos | 34650.0 | 34650.0 | 1.0 | False | None | None | False | None | False | 34650.0 | 0 |
2928631 | 96520 | None | RGU1353 | FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioningof 63mm mm dia single headed Gun mental Hydrant Valve with flangedinlet, stop valve, spindle and cast iron hand wheel. It has a femaleinstantaneous outlet with Blank Cap and is Hydrostatically tested to 21Kgfcm2 pressure having a flow rate of 900 LPM at 7 Kgfcm 2 ofpressure with blank cap and wheel as per IS 5290 etc. complete includingcost of materials, labour, usage charges of machinery complete as perspecifications | Nos | 11025.0 | 11025.0 | 12.0 | False | None | None | False | None | False | 132300.0 | 0 |
2928632 | 96520 | None | RGU1354 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 5250.0 | 5250.0 | 24.0 | False | None | None | False | None | False | 126000.0 | 0 |
2928633 | 96520 | None | RGU1355 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. | Each | 4725.0 | 4725.0 | 12.0 | False | None | None | False | None | False | 56700.0 | 0 |
2928634 | 96520 | None | RGU1356 | Supplying and fixing of Fire duct Shutter fabricated out of M.S.sheet andframe, door shall befixed with 4 mm thick Glass, suitable Rubber beadingand Locking arrangement. Rate shall be includes all fasteners etc, andcomplete shutter shall be powder coated of approved colour both inside andoutside | Sqm | 13125.0 | 13125.0 | 12.0 | False | None | None | False | None | False | 157500.0 | 0 |
2928635 | 96520 | None | RGU1357 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size20inchesx24inchesx10inches complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 6825.0 | 6825.0 | 12.0 | False | None | None | False | None | False | 81900.0 | 0 |
2928636 | 96520 | None | RGU1358 | Supplying Installing, testing and commissioning of 19mm dia 40.0mlength hose with rubber lining smooth bore, reinforced of naturalsyntheticfibres, a rubber cover finish shall be smooth, fluted or fabric marked withminimum thickness of 1.50mm and to with stand a working pressure of10Kgfsqcm confirms and tested as per IS 444 IS 12585 including cost ofmaterials, labour, usage charges of machinery complete as per specifications. | Each | 6300.0 | 6300.0 | 4.0 | False | None | None | False | None | False | 25200.0 | 0 |
2928637 | 96520 | None | RGU1359 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passingdrain pipe etc. and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size , including finishing complete so as tomake it leak proof. | Nos | 328.65 | 328.65 | 15.0 | False | None | None | False | None | False | 4929.75 | 0 |
2928638 | 96520 | None | RGU1360 | Supply, erection, testing and commissioning of 1inches GIMS collar. etc.,complete with all leads And lifts as per specifications and as directed by the Engineerincharge . | Nos | 115.5 | 115.5 | 20.0 | False | None | None | False | None | False | 2310.0 | 0 |
2928639 | 96520 | None | RGU1361 | Providing and fixing Steel work in built up tubular round, square or rectangular hollow tubes etc. trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. | Kg | 142.8 | 142.8 | 120.0 | False | None | None | False | None | False | 17136.0 | 0 |
2928640 | 96520 | None | RGU1362 | Supply and installation of CO2 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg, empty weight 1.7 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism Squeeze grip with easy snap safety seal , Range minimum 2 meters, applicable on Class A,8,C and electrically started Fire, 8 Rating 218, Can construction: Deep drawn andCo., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand and accessaries if it is fixing n floor MS brackets and accessories if it is fixing on wall,, labour, usage charges of machinery complete as per specifications. complete IS15683 and CE Approved. | Each | 6825.0 | 6825.0 | 3.0 | False | None | None | False | None | False | 20475.0 | 0 |
2928641 | 96520 | None | RGU1363 | Providing ABC Powder based MAP 50, 6Kg:Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50,Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees,Controllable discharge mechanism Squeeze grip with easy snap safety seal ,Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire,A Rating 3A, 8 Rating 218, Can construction : Deep drawn and Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, | Each | 2992.5 | 2992.5 | 30.0 | False | None | None | False | None | False | 89775.0 | 0 |
2928642 | 96520 | None | RGU1364 | Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8 andC Fire, 8 Rating 138, Can Constuctin : Hot spinningForging, Valve Construction : Forging and Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete | Each | 6825.0 | 6825.0 | 13.0 | False | None | None | False | None | False | 88725.0 | 0 |
2928643 | 96520 | None | RGU1365 | Providing Water Mist 4 Kg CO2 Gas Type Fire Extinguisher, used Unused Mechanism, Squeeze Grip , Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 600MM Diameter 108MM, Discharge Time less than 8 Secs, Controllable discharge mechanism, Applicable on Class B andC Fire, B Rating 13B, Can Constructing : Hot spinningForging, Value Construction : Forging and Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.0MM ISI Approved, 1 Year Warranty. With all Lead and Lifts etc., complete. as per the detailed specifications and the Directions of Engineer In charge of the work | Each | 9500.0 | 9500.0 | 12.0 | False | None | None | False | None | False | 114000.0 | 0 |
2928644 | 96520 | None | RGU1366 | Providing and fixing in position the following type of sign boards made out of 3mm thick inchesOpaqueinches PVC foam board with computer cut, PVC nonreflective self adhesive vinyl painted foam board, complete with mirror fasteners. Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used Non Radiocactive, nonphosphorous, non toxic and lead free. Available in different types and sizes, Time after removing the light source in minutes 60 minutes, Luminescent intensity milicandelas * per square meter mcdsqm : 30 mcdsqm.Luminescent Intensity greater than 0.32 mcdsqm, Period of Light Decay* In Minutes :3100, including cost of materials, labour, usage charges of machinery complete as per specifications. Signage with the following text inchesIN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISEinches Size:25cm x 30 cm | Sq CM | 2.1 | 2.1 | 9000.0 | False | None | None | False | None | False | 18900.0 | 0 |
2928645 | 96520 | None | RGU1367 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used Non Radiocactive, nonphosphorous, non toxic and lead free. Available in different types and sizes, Time after removing the light source in minutes 60 minutes, Luminescent intensity milicandelas * per square meter mcdsqm : 30 mcdsqm.Luminescent Intensity greater than 0.32 mcdsqm, Period of Light Decay* In Minutes :3100, including cost of materials, labour, usage charges of machinery complete as per specifications. Floor identification signage ie, GROUND FLOOR …etc. at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm. | Sq CM | 2.1 | 2.1 | 10800.0 | False | None | None | False | None | False | 22680.0 | 0 |
2928646 | 96520 | None | RGU1368 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used Non Radiocactive, nonphosphorous, non toxic and lead free. Available in different types and sizes, Time after removing the light source in minutes 60 minutes, Luminescent intensity milicandelas * per square meter mcdsqm : 30 mcdsqm.Luminescent Intensity greater than 0.32 mcdsqm, Period of Light Decay* In Minutes :3100, including cost of materials, labour, usage charges of machinery complete as per specifications. signage with text FIRE EXIT,Size shall be 15cm x 60cm. | Sq CM | 2.1 | 2.1 | 10800.0 | False | None | None | False | None | False | 22680.0 | 0 |
2928647 | 96520 | None | RGU1369 | Providing and fixing in position the signages inchesFIRE ORDERinches it should contain the following text on 3mm thick inchesOpaqueinches PVC foam board of computerized cut, PVC nonreflective self adhesive vinyl painted foam board of size 3' x 4'.A ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS. B EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS. C IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER. D BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.E IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. | Each | 2625.0 | 2625.0 | 12.0 | False | None | None | False | None | False | 31500.0 | 0 |
2928648 | 96520 | None | RGU1370 | ACTION BY SECURITYRECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.A ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: Current phone numbers to be provided in this location by the contractor C REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.E IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: Current phone numbers to be provided in this location by the contractor F FIRE FIGHTING AGENCY: PHONE : Current phone numbers to be provided in this location by the contractor FAX : Current fax numbers to be provided in this location by the contractor | Each | 2625.0 | 2625.0 | 12.0 | False | None | None | False | None | False | 31500.0 | 0 |
2928649 | 96520 | None | RGU1371 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used Non Radiocactive, nonphosphorous, non toxic and lead free. Available in different types and sizes, Time after removing the light source in minutes 60 minutes, Luminescent intensity milicandelas per square meter mcdsqm : 30 mcdsqm.Luminescent Intensity greater than 0.32 mcdsqm, Period of Light Decay In Minutes :3100, including cost of materials, labour, usage charges of machinery complete as per specifications. route plan Fire Escape Route Plan A2 Size | Sq CM | 2.1 | 2.1 | 89812.0 | False | None | None | False | None | False | 188605.2 | 0 |
2928650 | 96520 | None | RGU1372 | Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth including all lead and lift charges loading and unloading charges labour charges, curing, cost and conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work | Nos | 49500.0 | 49500.0 | 1.0 | False | None | None | False | None | False | 49500.0 | 0 |
2928651 | 96520 | None | RGU1373 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting do 40 Zone cansole. Complete | Nos | 85050.0 | 85050.0 | 1.0 | False | None | None | False | None | False | 85050.0 | 0 |
2928652 | 96520 | None | RGU1374 | P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front | Nos | 37012.5 | 37012.5 | 1.0 | False | None | None | False | None | False | 37012.5 | 0 |
2928653 | 96520 | None | RGU1375 | Supplying Installing, testing and commissioning of MIKE | Each | 5775.0 | 5775.0 | 1.0 | False | None | None | False | None | False | 5775.0 | 0 |
2928654 | 96520 | None | RGU1376 | Supplying Installing, testing and commissioning of Public address system Two way comminication type as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 2572.5 | 2572.5 | 12.0 | False | None | None | False | None | False | 30870.0 | 0 |
2928655 | 96520 | None | RGU1377 | Supply and Laying of 2 X 1.5 Sqmm fire alarm armored cable,6001000V rated with annealed copper conductor having XLPE insulation, steel wire armouring and FRLS outer sheath complete as required. | Mtr | 181.65 | 181.65 | 650.0 | False | None | None | False | None | False | 118072.5 | 0 |
2928656 | 96520 | None | RGU1378 | Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character 240X64 Pixel 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20percent spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126240 detectors devices in any combination with key pad, dual flashbased microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10percent with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMSintegration MODBUS BACKNET, graphical software for provision of TCP IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor and control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels Nodes in one network with all other accessories required to successfully run the system. The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design . Approval: VDSULEN54 Std. Make:Advanced UK , Argus, Uk Simplex, Notifier 2 Loop Panel | Each | 220500.0 | 220500.0 | 1.0 | False | None | None | False | None | False | 220500.0 | 0 |
2928657 | 96520 | None | RGU1379 | Supplying Installing, testing and commissioning of electronic Hooter, it conists ofelectronic circuit to give dual Fire alaram sound with works.24V DC with speaker all encased in suitable in MS 16 gauge red painted box.complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 5040.0 | 5040.0 | 18.0 | False | None | None | False | None | False | 90720.0 | 0 |
2928658 | 96520 | None | RGU1380 | Supplying Installing, testing and commissioning of electronic Hooter, itconists of electronic circuit to give dual Fire alaram sound with works. 24VDC with speaker all encased in suitable in MS 16 gauge red painted box.complete including cost of materials, labour, usage charges of machinerycomplete as per specifications. | Each | 1575.0 | 1575.0 | 18.0 | False | None | None | False | None | False | 28350.0 | 0 |
2928659 | 96520 | None | RGU1381 | Supplying and fixing sheet Metal box made out of 18 SWGsheet metal with necessary holes for cableconduit entry asrequired with one coat of primer of approved make etc.100 x 75 x 65 mm | Each | 123.9 | 123.9 | 50.0 | False | None | None | False | None | False | 6195.0 | 0 |
2928660 | 96520 | None | RGU1382 | Supply, install, test and commissioning of Analogue addressable Monitor CumControl InputOutput module 1+1 with inbuilt relay and isolator with LEDindicator, approved to operate in 10 degree C to +55 degree C temperature, complies with theessential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item. For DetectorsDevice without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detectordevice Approval: EN54. | Each | 4095.0 | 4095.0 | 3.0 | False | None | None | False | None | False | 12285.0 | 0 |
2928661 | 96520 | None | RGU1383 | Supply, intallation, testing and Commissioning of 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws RED colour | Mtr | 181.65 | 181.65 | 1500.0 | False | None | None | False | None | False | 272475.0 | 0 |
2928662 | 96520 | None | RGU1384 | SITC of 7AM12 V Battery for fire alarm system | Each | 1124.55 | 1124.55 | 2.0 | False | None | None | False | None | False | 2249.1 | 0 |
2928663 | 96520 | None | RGU1385 | Preparation of architectural drawings, as per I.S Codes and got it proof checked from IISCIITREC or any other equivalent reputed agency. Prepration of drawings and estimate for internal and external Electrical works, public health, engineering, fire fighting, roads, drains, acoustic treatment, land scaping, rain water harvesting, sewage treatement plant, hvac, mgps , Nurse calling system , BMS etc., etc., complete with all lead and lift, as per specifications and as per directions of the Engineer in charge of the work. | Lot | 5823000.0 | 5823000.0 | 1.0 | False | None | None | False | None | False | 5823000.0 | 0 |