tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1709797413000 | 0 | None | None | Buildings | Constuction of building SJJM at Byadgi town in Byadgi taluk | 169734.19 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2955444 | 97681 | None | 1.5.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir draft,
approach channels, key trench, foundation of Bridges and such similar works,
as per drawing and technical specifications, including setting out, shoring,
strutting, barricading, caution lights, excavated surface leveled and sides neatly
dressed disposing off or leveling the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost
of labour, tools, usage & other appurtenances required to complete the work.In ordinary/soft rock without blasting upto 1.5 m dept | Cum | 299.0 | 299.0 | 24.43 | False | None | None | False | None | False | 7304.57 | 0 | 2955445 | 97681 | None | 2.1.2 V-1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 2.38 | False | None | None | False | None | False | 13480.32 | 0 | 2955446 | 97681 | None | 2.1.4 V-1 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6217.0 | 6217.0 | 1.6 | False | None | None | False | None | False | 9947.2 | 0 | 2955447 | 97681 | None | 6.3- V-02 | Providing Brick work with common burnt clay modular bricks of class
designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement
: 4 coarse sand) including cost of all materials, labour, scaffolding and
usage charges of machinery & other incidental charges complete as per
the direction of engineer incharge of work. | Cum | 8874.0 | 8874.0 | 9.2 | False | None | None | False | None | False | 81640.8 | 0 | 2955448 | 97681 | None | 2.2.1 Vol-1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. | Cum | 6287.0 | 6287.0 | 1.35 | False | None | None | False | None | False | 8487.45 | 0 | 2955449 | 97681 | None | 2.11 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. | t | 89457.0 | 89457.0 | 0.1215 | False | None | None | False | None | False | 10869.0255 | 0 | 2955450 | 97681 | None | S No-15 V-01 | RCC Roof Slabs Percentage Additionalities for Formwork,
Centering & ScaffoldingPercentage on finished rate
of concrete per m 50% | Cum | 3143.5 | 3143.5 | 1.35 | False | None | None | False | None | False | 4243.725 | 0 | 2955451 | 97681 | None | 2.35.1 Vol-04 | Providing and constructing vertical /inclined graded filter media
using clean, hard graded sand and coarse aggregates from approved
source satisfying specified filter criteria in layers of specified thickness
including cost of all materials, machinery, labour, laying to required
slopes, compacting and all other ancillary operations complete as per
specifications and approved drawings.Sand layer | Cum | 2092.0 | 2092.0 | 1.3 | False | None | None | False | None | False | 2719.6 | 0 | 2955452 | 97681 | None | 2.35.4 Vol-04 | Providing and constructing vertical /inclined graded filter media
using clean, hard graded sand and coarse aggregates from approved
source satisfying specified filter criteria in layers of specified thickness
including cost of all materials, machinery, labour, laying to required
slopes, compacting and all other ancillary operations complete as per
specifications and approved drawings 40 mm down graded coarse aggregate layer | Cum | 1806.0 | 1806.0 | 1.3 | False | None | None | False | None | False | 2347.8 | 0 | 2955453 | 97681 | None | 11.2 PWD SR 2018-19 | Providing and laying in position to required level or slope 150mm internal diameter salt glazed stone ware pipes grade A and jointing with stiff mixture of cement mortor in proportion of 1:1 testing of pipes and joints, including cost of materials, labour charges complete as per specifications.Specifications No | m | 380.07 | 380.07 | 10.0 | False | None | None | False | None | False | 3800.7 | 0 | 2955454 | 97681 | None | 8.9 Vol-02 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a
top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge | Sqm | 385.0 | 385.0 | 16.2 | False | None | None | False | None | False | 6237.0 | 0 | 2955455 | 97681 | None | 14.2.1 Vol-02 | Providing and fixing white vitreous china pedestal type water closet
(European type W.C. pan) with seat and lid, 10 litre low level white P.V.C.
flushing cistern, including flush pipe, with manually controlled device
(handle lever), conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required W.C. pan with ISI marked white solid plastic seat and lid | Each | 4838.0 | 4838.0 | 2.0 | False | None | None | False | None | False | 9676.0 | 0 | 2955456 | 97681 | None | 13.50.1 VOL-02 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 80 mm nominal dia Pipes ( PWDSR 23-24 Item no 13.50.1) | m | 674.0 | 674.0 | 10.0 | False | None | None | False | None | False | 6740.0 | 0 | 2955457 | 97681 | None | 13.50.2 vOL-02 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal dia Pipes ( PWDSR 23-24 Item no 13.50.1) | m | 224.0 | 224.0 | 10.0 | False | None | None | False | None | False | 2240.0 | 0 |
| 1709797413000 | 0 | None | None | Buildings | Construction Of Boys Toilet In S J J M School At Byadagi Town | 338689.11 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2955458 | 97682 | None | 1.5.1 V-1 | Earth work excavation by manual means for drains,canals, waste weir
draft, approach channels, key trench, foundation of Bridges and such
similar works, as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, excavated
surface leveled and sides neatly dressed disposing off or leveling the
excavated stuff or sorting & stacking the selected stuff for reuse in a
radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage
& other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 299.0 | 299.0 | 16.75 | False | None | None | False | None | False | 5008.25 | 0 | 2955459 | 97682 | None | 2.1.2 Vol-01 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 1.54 | False | None | None | False | None | False | 8722.56 | 0 | 2955460 | 97682 | None | 1.9 vol-01 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m | Cum | 433.0 | 433.0 | 13.16 | False | None | None | False | None | False | 5698.28 | 0 | 2955461 | 97682 | None | 5.1.1 Vol-02 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : | Cum | 5611.0 | 5611.0 | 9.17 | False | None | None | False | None | False | 51452.87 | 0 | 2955462 | 97682 | None | 2.2.1 Vol-01 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6287.0 | 6287.0 | 7.19 | False | None | None | False | None | False | 45203.53 | 0 | 2955463 | 97682 | None | 2.11 Vol-1 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (PWD SR 2023-24 Vol 1 Item no 2.11 ) All other type of structures | t | 89457.0 | 89457.0 | 0.5035 | False | None | None | False | None | False | 45041.5995 | 0 | 2955464 | 97682 | None | Sl.No-15 V No-01 | centeriong and shuttering RCC Roof Slabs 50% | Cum | 3143.5 | 3143.5 | 2.64 | False | None | None | False | None | False | 8298.84 | 0 | 2955465 | 97682 | None | Sl No-14 Vol No-01 | Percentage Additionalities for Formwork,
Centering & Scaffoldin RCC Beams, Lintels & Troughs of Aqueducts 60% | Cum | 3772.2 | 3772.2 | 1.44 | False | None | None | False | None | False | 5431.968 | 0 | 2955466 | 97682 | None | 6.32 Vol-02 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Cum | 1310.0 | 1310.0 | 41.58 | False | None | None | False | None | False | 54469.8 | 0 | 2955467 | 97682 | None | 8.2.1 vol-02 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 295.0 | 295.0 | 101.49 | False | None | None | False | None | False | 29939.55 | 0 | 2955468 | 97682 | None | 8.35 vol-02 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR 2023-24 Vol 8.25 Item no ) | Sqm | 137.0 | 137.0 | 99.15 | False | None | None | False | None | False | 13583.55 | 0 | 2955469 | 97682 | None | 8.31 vol-02 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one coats) as per specifications and as per directions of Engineer in charge. | Sqm | 131.0 | 131.0 | 29.97 | False | None | None | False | None | False | 3926.07 | 0 | 2955470 | 97682 | None | 9.10 Vol-02 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. ( PWD Sr 23-24 Item no 9.10 Vol 2) | Sqm | 1106.0 | 1106.0 | 28.67 | False | None | None | False | None | False | 31709.02 | 0 | 2955471 | 97682 | None | 11.5.2 Vol-02 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( | Sqm | 4242.0 | 4242.0 | 0.36 | False | None | None | False | None | False | 1527.12 | 0 | 2955472 | 97682 | None | 9.35 Vol -02 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. (PWD SR 2023-24 Vol 2 Item no 9.35) | Sqm | 1636.0 | 1636.0 | 4.5 | False | None | None | False | None | False | 7362.0 | 0 | 2955473 | 97682 | None | 12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. | Sqm | 1.89 | 1.89 | 2040.0 | False | None | None | False | None | False | 3855.6 | 0 | 2955474 | 97682 | None | 13.32.1 Vol 02 | Providing & fixing Chorinated Poly Venyl Chloride (CPVC) Pipes conforming to IS 15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete (internal work exposed on wall 15mm normal dia pipes | m | 309.0 | 309.0 | 20.0 | False | None | None | False | None | False | 6180.0 | 0 | 2955475 | 97682 | None | 14.1 Vol-02 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: 581x 44mm | Each | 4884.0 | 4884.0 | 1.0 | False | None | None | False | None | False | 4884.0 | 0 | 2955476 | 97682 | None | 14.7.7 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap | No | 2099.0 | 2099.0 | 1.0 | False | None | None | False | None | False | 2099.0 | 0 | 2955477 | 97682 | None | 1.2.1 Vol-06 | Concealed conduit system : Supplying . . . . heavy gauge PVC conduit pipe mm dia mm mm thick with Suitable size bends, metal/PVC junction boxes adhesive paste. Etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of juction boxes and pipe ends. run with 18SWG GI fish wire wherever necessary. | m | 66.0 | 66.0 | 10.0 | False | None | None | False | None | False | 660.0 | 0 | 2955478 | 97682 | None | 1.3.1 Vol 06 | Supplying heavy gauge PVC Counduit Pipe… dia…Mm thick with sutable size bends, metal junction boxes adhesive paste etc… by groove cutting in the wall and fixing by braching U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessry ( SR 23-24 ELECTRIFICATION Supplying heavy gauge PVC Counduit Pipe… dia…Mm thick with sutable size bends, metal junction boxes adhesive paste etc… by groove cutting in the wall and fixing by braching U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessry ( SR 23-24 ELECTRIFICATION Vol 6 page No 1.3.1 Chapter 1)Chapter 1) | m | 68.0 | 68.0 | 10.0 | False | None | None | False | None | False | 680.0 | 0 | 2955479 | 97682 | None | 2.1.1 vol-06 | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch ( SR 2023-24 ELECTRIFICATION Vol 6 page No 2.1.1 Chapter 2) | Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 2955480 | 97682 | None | 2.2.1 Vol-06 | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch | Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 2955481 | 97682 | None | Vol 6- 2.2.3 Chapter 2 | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto6Mtr form tapping to out let via seitch | Point | 555.0 | 555.0 | 1.0 | False | None | None | False | None | False | 555.0 | 0 | 2955482 | 97682 | None | Vol 6 -11.3.1 Chapter 11 | Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burninghours 70% lumen aintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting1 2-9/10W | Each | 551.0 | 551.0 | 1.0 | False | None | None | False | None | False | 551.0 | 0 | 2955483 | 97682 | None | Vol 6 - 2.3.3 Chapter 2 | Wiring for lighting/power circuit using one of FRLS PVC onsulated 1100V grade, multis and Copper conductor single core in open or consealed system of wiring. Using Class 'A' approved materials ( SR 23-24 ELECTRIFICATION | m | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 | 2955484 | 97682 | None | Vol 6 - 3.1.2Chapter 3 | Supplying 6A flush/projected type socket and a 6amps flush/ projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required.6Amps 3/5 way ( SR 23-24 ELECTRIFICATION ) | Each | 147.0 | 147.0 | 1.0 | False | None | None | False | None | False | 147.0 | 0 | 2955485 | 97682 | None | Vol 6 - 3.8Chapter 3 | Supplying 4mm ickplasticsheetwithnecessrynitchesforfixingswitches,regulations etc, and fixing on existing wooden or metal box using N.F screws( SR 23-24 ELECTRIFICATION Vol 6 page No3.8Chapter 3) | Sq CM | 0.41 | 0.41 | 750.0 | False | None | None | False | None | False | 307.5 | 0 | 2955486 | 97682 | None | Vol 6 -2.1.4 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers etc. GI wire | m | 17.0 | 17.0 | 10.0 | False | None | None | False | None | False | 170.0 | 0 | 2955487 | 97682 | None | Vol 6 -1.6 Chapter 1 | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" x12"x3"(300x300x76mm) ( SR23-24 ELECTRIFICATION Vol 6 page No 1.6 Chapter 1) | Each | 120.0 | 120.0 | 1.0 | False | None | None | False | None | False | 120.0 | 0 | 2955488 | 97682 | None | Vol 6 -1.6 Chapter 1 | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete12" x9"x3"(300x228x76mm) | Each | 115.0 | 115.0 | 1.0 | False | None | None | False | None | False | 115.0 | 0 |
| 1709797413000 | 0 | None | None | Buildings | Construction Of Ladies Toilet in S J JM School In Byadagi Town | 338349.11 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2955489 | 97683 | None | PWD SR 2023-24 Item nO 1.5.1 Vol 1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work | Cum | 299.0 | 299.0 | 16.75 | False | None | None | False | None | False | 5008.25 | 0 | 2955490 | 97683 | None | PWD SR 2023-24 Vol 1 Item no 2.1.1CHAPTE | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 1.54 | False | None | None | False | None | False | 8722.56 | 0 | 2955491 | 97683 | None | PWD SR 23-24 Item no 1.11 Vol 1 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m. | Cum | 433.0 | 433.0 | 13.16 | False | None | None | False | None | False | 5698.28 | 0 | 2955492 | 97683 | None | PWD SR 2023-24 Vol 2 Item no 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with | Cum | 5611.0 | 5611.0 | 9.17 | False | None | None | False | None | False | 51452.87 | 0 | 2955493 | 97683 | None | PWD SR 2023-24 Item no 2.2.1 Vol 2 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6287.0 | 6287.0 | 7.19 | False | None | None | False | None | False | 45203.53 | 0 | 2955494 | 97683 | None | PWD SR 2023-24 Vol 1 Item no 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | t | 89457.0 | 89457.0 | 0.5035 | False | None | None | False | None | False | 45041.5995 | 0 | 2955495 | 97683 | None | sL-NO15 VOL 1 | RCC Roof Slabs 50% Percentage Additionalities for Formwork,
Centering & Scaffolding | Cum | 3143.5 | 3143.5 | 2.64 | False | None | None | False | None | False | 8298.84 | 0 | 2955496 | 97683 | None | Vol-01 Sl.no-14 | RCC Beams, Lintels & Troughs of Aqueducts 60% Percentage Additionalities for Formwork,
Centering & Scaffolding | Cum | 3772.2 | 3772.2 | 1.44 | False | None | None | False | None | False | 5431.968 | 0 | 2955497 | 97683 | None | PWD SR 2023-24 Item no 6.32 Vol 2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1310.0 | 1310.0 | 41.58 | False | None | None | False | None | False | 54469.8 | 0 | 2955498 | 97683 | None | PWD SR 23-24 Item no 8.2.1 Vol 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 295.0 | 295.0 | 101.49 | False | None | None | False | None | False | 29939.55 | 0 | 2955499 | 97683 | None | PWD SR 2023-24 Vol -02 i no-8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 137.0 | 137.0 | 99.15 | False | None | None | False | None | False | 13583.55 | 0 | 2955500 | 97683 | None | PWD SR 23-24Vol 2 Item no 8.37 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one coats) as per specifications and as per directions of Engineer in charge | Sqm | 131.0 | 131.0 | 29.97 | False | None | None | False | None | False | 3926.07 | 0 | 2955501 | 97683 | None | PWD Sr 23-24 Item no 9.10 Vol 2 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1106.0 | 1106.0 | 28.67 | False | None | None | False | None | False | 31709.02 | 0 | 2955502 | 97683 | None | WD SR 2023-24 Item no 11.5.2 Vol 2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4242.0 | 4242.0 | 0.36 | False | None | None | False | None | False | 1527.12 | 0 | 2955503 | 97683 | None | PWD SR 2023-24 Vol 2 Item no 9.35 | Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications | Sqm | 1636.0 | 1636.0 | 4.5 | False | None | None | False | None | False | 7362.0 | 0 | 2955504 | 97683 | None | PWD SR 23-24 Volume NO 2 Item No12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges | Sqm | 2040.0 | 2040.0 | 1.89 | False | None | None | False | None | False | 3855.6 | 0 | 2955505 | 97683 | None | PWD SR 23-24 P.No.93. I.No.13.32. Vol-02 | Providing & fixing Chorinated Poly Venyl Chloride (CPVC) Pipes conforming to IS 15778 having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete (internal work exposed on wall 15 mm nromal dia pipe | m | 309.0 | 309.0 | 20.0 | False | None | None | False | None | False | 6180.0 | 0 | 2955506 | 97683 | None | PWD SR 2023-24 Vol 2 Item no 14.1 Chapter - 14 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required | Each | 4554.0 | 4554.0 | 1.0 | False | None | None | False | None | False | 4554.0 | 0 | 2955507 | 97683 | None | PWD SR 2023-24 Vol 2 Item no 14.7.7 Chapter -1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap | Each | 2099.0 | 2099.0 | 1.0 | False | None | None | False | None | False | 2099.0 | 0 | 2955508 | 97683 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 1.2.1 | Concealed conduit system : Supplying . . . . heavy gauge PVC conduit pipe mm dia mm mm thick with Suitable size bends, metal/PVC junction boxes adhesive paste. Etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of juction boxes and pipe ends. run with 18SWG GI fish wire wherever necessary | m | 66.0 | 66.0 | 10.0 | False | None | None | False | None | False | 660.0 | 0 | 2955509 | 97683 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 1.2.1 | Supplying heavy gauge PVC Counduit Pipe… dia…Mm thick with sutable size bends, metal junction boxes adhesive paste etc… by groove cutting in the wall and fixing by braching U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessry | m | 68.0 | 68.0 | 10.0 | False | None | None | False | None | False | 680.0 | 0 | 2955510 | 97683 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 2.1.1 | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch | Per Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 2955511 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.1.1 | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch | Point | 285.0 | 285.0 | 1.0 | False | None | None | False | None | False | 285.0 | 0 | 2955512 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.2.3 | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto6Mtr form tapping to out let via seitch | Point | 555.0 | 555.0 | 1.0 | False | None | None | False | None | False | 555.0 | 0 | 2955513 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 11.3.1 C | Supplying offeet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 1.0 | False | None | None | False | None | False | 551.0 | 0 | 2955514 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC onsulated 1100V grade, multis and Copper conductor single core in open or consealed system of wiring. Using Class 'A' approved materials | m | 42.0 | 42.0 | 10.0 | False | None | None | False | None | False | 420.0 | 0 | 2955515 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 3.1.2Ch3 | Supplying 6A flush/projected type socket and a 6amps flush/ projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required.6Amps 3/5 wayapter | Each | 147.0 | 147.0 | 1.0 | False | None | None | False | None | False | 147.0 | 0 | 2955516 | 97683 | None | SR23-24 ELECTRIFICATION Vol 6 page No3.10Chapter | Supplying 4mm thickplasticsheetwithnecessrynitchesforfixingswitches,regulations etc, and fixing on existing wooden or metal box using N.F screws | Sq CM | 0.41 | 0.41 | 750.0 | False | None | None | False | None | False | 307.5 | 0 | 2955517 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No2.1.4Chap | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers etc. GI wire | m | 17.0 | 17.0 | 10.0 | False | None | None | False | None | False | 170.0 | 0 | 2955518 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.6 Chap | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" x12"x3"(300x300x76mm) | Each | 120.0 | 120.0 | 1.0 | False | None | None | False | None | False | 120.0 | 0 | 2955519 | 97683 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.7 Chap | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" x9"x3"(300x228x76mm) | Each | 105.0 | 105.0 | 1.0 | False | None | None | False | None | False | 105.0 | 0 |
| 1709797413000 | 0 | None | None | Buildings | Constuction of School Building Govt S J J M Building Primary School in Byadagi town | 2348671.13 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2955520 | 97684 | None | PWD SR 2023-24 Item nO 1.5.1 Vol 1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work | Cum | 299.0 | 299.0 | 15.7 | False | None | None | False | None | False | 4694.3 | 0 | 2955521 | 97684 | None | PWD SR 2023-24 Vol 1 Item no 2.1.1CHAPTEr 2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5664.0 | 5664.0 | 4.47 | False | None | None | False | None | False | 25318.08 | 0 | 2955522 | 97684 | None | PWD SR 23-24 Item no 1.11 Vol 1 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m | Cum | 433.0 | 433.0 | 13.3 | False | None | None | False | None | False | 5758.9 | 0 | 2955523 | 97684 | None | PWD SR 2023-24 Vol 1 Item no 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with | Cum | 5611.0 | 5611.0 | 13.1 | False | None | None | False | None | False | 73504.1 | 0 | 2955524 | 97684 | None | PWD SR 23-24 Item no 2.5.1 Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6630.0 | 6630.0 | 55.1 | False | None | None | False | None | False | 365313.0 | 0 | 2955525 | 97684 | None | PWD SR 2023-24 Vol 1 Item no 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures | t | 89457.0 | 89457.0 | 4.407 | False | None | None | False | None | False | 394236.999 | 0 | 2955526 | 97684 | None | VOL -01 S NO-15 | Percentage Additionalities for Formwork,
Centering & Scaffolding RCC Roof Slabs 50% | Cum | 3315.0 | 3315.0 | 31.04 | False | None | None | False | None | False | 102897.6 | 0 | 2955527 | 97684 | None | vOL-01 s l nO-14 | RCC Columns / Shaft (Slip Centering) 70% Percentage Additionalities for Formwork,
Centering & Scaffolding | Cum | 4641.0 | 4641.0 | 9.99 | False | None | None | False | None | False | 46363.59 | 0 | 2955528 | 97684 | None | VOL-01 S.N0-14 | Percentage Additionalities for Formwork,
Centering & Scaffolding RCC Beams, Lintels & Troughs of Aqueducts 60% | Cum | 3978.0 | 3978.0 | 11.79 | False | None | None | False | None | False | 46900.62 | 0 | 2955529 | 97684 | None | VOL-01 S NO-19 | hejjas, Canopy & Other Architectural projections of
minor sections Percentage Additionalities for Formwork45%,
Centering & Scaffolding | Cum | 2983.5 | 2983.5 | 0.52 | False | None | None | False | None | False | 1551.42 | 0 | 2955530 | 97684 | None | PWD SR 2023-24 Item no 6.32 Vol 2 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1310.0 | 1310.0 | 385.25 | False | None | None | False | None | False | 504677.5 | 0 | 2955531 | 97684 | None | PWD SR 23-24 Item no 8.2.1 Vol 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 295.0 | 295.0 | 320.62 | False | None | None | False | None | False | 94582.9 | 0 | 2955532 | 97684 | None | PWD SR23-24 Item no 8.9 Vol 2 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 385.0 | 385.0 | 229.83 | False | None | None | False | None | False | 88484.55 | 0 | 2955533 | 97684 | None | pWD SR 2023-24 Item no 9.17 Vol 2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete) | Sqm | 1112.0 | 1112.0 | 221.72 | False | None | None | False | None | False | 246552.64 | 0 | 2955534 | 97684 | None | PWD SR 2023-24 Vol 8.25 Item no | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 137.0 | 137.0 | 784.17 | False | None | None | False | None | False | 107431.29 | 0 | 2955535 | 97684 | None | PWD SR 23-24 Vol 2 Item no 11.34 A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 168.0 | 168.0 | 221.76 | False | None | None | False | None | False | 37255.68 | 0 | 2955536 | 97684 | None | PWD SR 2023-24 Item no 11.5.2 Vol 2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4242.0 | 4242.0 | 17.49 | False | None | None | False | None | False | 74192.58 | 0 | 2955537 | 97684 | None | PWD SR 2023-24 Vol 2 Item no 8.37 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one coats) as per specifications and as per directions of Engineer in charge.Revised Rate W.E.F. 07-07-2022 | Sqm | 131.0 | 131.0 | 165.78 | False | None | None | False | None | False | 21717.18 | 0 | 2955538 | 97684 | None | VOL-02- ITEM NO-133.1 | Providing Wall Black boards CM 1:3 with two coats of black paint including finishing etc. Including cast of materials labour HOM complete as per specifications | No | 869.4 | 869.4 | 3.0 | False | None | None | False | None | False | 2608.2 | 0 | 2955539 | 97684 | None | SR 23-24ELECTRIFICATION Vol 6 page No 1.2.1 Cha | Concealed conduit system : Supplying . . . . heavy gauge PVC conduit pipe mm dia mm mm thick with Suitable size bends, metal/PVC junction boxes adhesive paste. Etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of juction boxes and pipe ends. run with 18SWG GI fish wire wherever necessary. | m | 66.0 | 66.0 | 300.0 | False | None | None | False | None | False | 19800.0 | 0 | 2955540 | 97684 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.2.1 Cha | Supplying heavy gauge PVC Counduit Pipe… dia…Mm thick with sutable size bends, metal junction boxes adhesive paste etc… by groove cutting in the wall and fixing by braching U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessry 19/20 mm dia 2mm | m | 68.0 | 68.0 | 300.0 | False | None | None | False | None | False | 20400.0 | 0 | 2955541 | 97684 | None | SR 223-24 ELECTRIFICATION Vol 6 page No 2.1.1 C | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch | Point | 285.0 | 285.0 | 14.0 | False | None | None | False | None | False | 3990.0 | 0 | 2955542 | 97684 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.2.1 Ch | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch | Point | 285.0 | 285.0 | 12.0 | False | None | None | False | None | False | 3420.0 | 0 | 2955543 | 97684 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 2.2.3 C | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto6Mtr form tapping to out let via seitch | Point | 555.0 | 555.0 | 10.0 | False | None | None | False | None | False | 5550.0 | 0 | 2955544 | 97684 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 11.3.1 | Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 1.0 | False | None | None | False | None | False | 551.0 | 0 | 2955545 | 97684 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC onsulated 1100V grade, multis and Copper conductor single core in open or consealed system of wiring. Using Class 'A' approved materials | m | 42.0 | 42.0 | 280.0 | False | None | None | False | None | False | 11760.0 | 0 | 2955546 | 97684 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No 3.1.2C | Supplying 6A flush/projected type socket and a 6amps flush/ projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required.6Amps 3/5 way | Each | 146.0 | 146.0 | 8.0 | False | None | None | False | None | False | 1168.0 | 0 | 2955547 | 97684 | None | SR 2023-24 ELECTRIFICATION Vol 6 page No3.10Chap | Supplying 4mm thickplasticsheetwithnecessrynitchesforfixingswitches,regulations etc, and fixing on existing wooden or metal box using N.F screws) | Sq CM | 0.41 | 0.41 | 3000.0 | False | None | None | False | None | False | 1230.0 | 0 | 2955548 | 97684 | None | SR 2023-24 ELECTRIFICATION Vol 6 pageNo 6.3Chap | Supplyingcapacitortypecellingfancompletewithdownroadblades,shakle,canopiesetc., for operating on 230 Volts, 50Cycles. Single fase AC supplyconforming to ISS- 374-1979 & with double ball bearing system. 48"Sweep (1200)mm Regular model (khaitan,coromptongreaves,orientpolar,bajaj,Usha,Havells,Almonard(P.No.23,I.No. 23 (1) (a)) | No | 2984.0 | 2984.0 | 6.0 | False | None | None | False | None | False | 17904.0 | 0 | 2955549 | 97684 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 5.17.1C | Supplying and fixing minitaure circuit breakers on existing MCB distribution board using necessary fixing materials and "C" Type curve, indic wiring complete as required. Indicator ON\OFF, energy cross 3 with short corcuit breaking of 10k and Complete wiring as required | Each | 739.0 | 739.0 | 3.0 | False | None | None | False | None | False | 2217.0 | 0 | 2955550 | 97684 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 5.18.1Cha | Supplying and fixing regular MCB distribution boards on wall / wood board/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3phase/single door with powder coated painting etc., complete. Double door) | No | 1241.0 | 1241.0 | 6.0 | False | None | None | False | None | False | 7446.0 | 0 | 2955551 | 97684 | None | SR 23-24 ELECTRIFICATION Vol 6 page No2.1.4Chap | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers etc. GI wire | m | 17.0 | 17.0 | 400.0 | False | None | None | False | None | False | 6800.0 | 0 | 2955552 | 97684 | None | SR 23-24ELECTRIFICATION Vol 6 page No 1.6 Chap | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" x12"x3"(300x300x76mm) | Each | 120.0 | 120.0 | 3.0 | False | None | None | False | None | False | 360.0 | 0 | 2955553 | 97684 | None | SR 23-24ELECTRIFICATION Vol 6 page No 1.6 Chapte | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" x9"x3"(300x228x76mm) | Each | 115.0 | 115.0 | 6.0 | False | None | None | False | None | False | 690.0 | 0 | 2955554 | 97684 | None | SR 23-24ELECTRIFICATION Vol 6 page No 1.8 Chapt | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete10" x7"x3"(254x178x76mm) | Each | 112.0 | 112.0 | 12.0 | False | None | None | False | None | False | 1344.0 | 0 |
| 1709797413000 | 0 | None | None | Buildings | Construction Of Pre primary School Room IN S J J M School At Byadagi | 999611.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2955555 | 97685 | None | PWD SR 23-24 Item no 2.5.1Vol 1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mmnominal size graded crushed coarse aggregates | Cum | 6630.0 | 6630.0 | 16.81 | False | None | None | False | None | False | 111450.3 | 0 | 2955556 | 97685 | None | PWD SR 2023-24 Vol 1 Item no 2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structures | t | 89457.0 | 89457.0 | 1.5965 | False | None | None | False | None | False | 142818.1005 | 0 | 2955557 | 97685 | None | Volno-01 Sl no-9 | RCC Columns / Shaft (Slip Centering)70% Percentage Additionalities for Formwork,
Centering & Scaffoldin | Cum | 4641.0 | 4641.0 | 2.75 | False | None | None | False | None | False | 12762.75 | 0 | 2955558 | 97685 | None | vol-01 S No-15 | Percentage Additionalities for Formwork,
Centering & Scaffoldin Curved RCC Roof Slabs, Domes & Sloped Roofs70% | Cum | 1326.0 | 1326.0 | 10.08 | False | None | None | False | None | False | 13366.08 | 0 | 2955559 | 97685 | None | vol no-01 s no-14 | Percentage Additionalities for Formwork,
Centering & Scaffoldin RCC Beams, Lintels & Troughs of Aqueducts 60% | Cum | 1326.0 | 1326.0 | 5.1 | False | None | None | False | None | False | 6762.6 | 0 | 2955560 | 97685 | None | vol-01 S N-19 | – Percentage Additionalities for Formwork,
Centering & Scaffoldin Chejjas, Canopy & Other Architectural projections ofminor sections 45% | Cum | 2983.5 | 2983.5 | 0.14 | False | None | None | False | None | False | 417.69 | 0 | 2955561 | 97685 | None | PWD SR 2023-24 Item no 6.32 Vol 1 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1310.0 | 1310.0 | 87.12 | False | None | None | False | None | False | 114127.2 | 0 | 2955562 | 97685 | None | PWD SR 23-24 Vol 2 Item no 11.34 A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 168.0 | 168.0 | 829.08 | False | None | None | False | None | False | 139285.44 | 0 | 2955563 | 97685 | None | PWD SR 23-24 Vol 2 Item no 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub- bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent | Sqm | 2466.0 | 2466.0 | 86.22 | False | None | None | False | None | False | 212618.52 | 0 | 2955564 | 97685 | None | pwd sr 23-24 iTEM NO 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 138.0 | 138.0 | 400.0 | False | None | None | False | None | False | 55200.0 | 0 | 2955565 | 97685 | None | PWD SR 2023-24 Item no 11.5.2 Vol 2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 4242.0 | 4242.0 | 6.21 | False | None | None | False | None | False | 26342.82 | 0 | 2955566 | 97685 | None | PWD SR 2023-24 Vol 2 Item no 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 241.0 | 241.0 | 61.76 | False | None | None | False | None | False | 14884.16 | 0 | 2955567 | 97685 | None | PWD SR 23-24 Item no 8.2.1 Vol 2 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 295.0 | 295.0 | 85.07 | False | None | None | False | None | False | 25095.65 | 0 | 2955568 | 97685 | None | PWD SR23-24 Item no 8.9 Vol 2 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 385.0 | 385.0 | 90.03 | False | None | None | False | None | False | 34661.55 | 0 | 2955569 | 97685 | None | PWD SR 2023-24 Vol 8.25 Item no | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in- cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 137.0 | 137.0 | 152.39 | False | None | None | False | None | False | 20877.43 | 0 | 2955570 | 97685 | None | PWD SR 2023-24 Item nO 8.31 Vol 2 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 283.0 | 283.0 | 129.03 | False | None | None | False | None | False | 36515.49 | 0 | 2955571 | 97685 | None | PWD SR 2023-24 Vol 2 Item no8.37 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Old work (one coats) as per specifications and as per directions of Engineer in charge | Sqm | 131.0 | 131.0 | 13.97 | False | None | None | False | None | False | 1830.07 | 0 | 2955572 | 97685 | None | PWD SR 2023-24 Item nO 11.32 Vol 2 | Providing Wall Black boards CM 1:3 with two coats of black paint including finishing etc. Including cast of materials labour HOM complete as per specifications | No | 869.4 | 869.4 | 1.0 | False | None | None | False | None | False | 869.4 | 0 | 2955573 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.1.1 C | Concealed conduit system : Supplying . . . . heavy gauge PVC conduit pipe mm dia mm mm thick with Suitable size bends, metal/PVC junction boxes adhesive paste. Etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of juction boxes and pipe ends. run with 18SWG GI fish wire wherever necessary | m | 66.0 | 66.0 | 40.0 | False | None | None | False | None | False | 2640.0 | 0 | 2955574 | 97685 | None | SR23-24 ELECTRIFICATION Vol 6 page No 1.2.1 Cha | Supplying heavy gauge PVC Counduit Pipe… dia…Mm thick with sutable size bends, metal junction boxes adhesive paste etc… by groove cutting in the wall and fixing by braching U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessry | m | 68.0 | 68.0 | 40.0 | False | None | None | False | None | False | 2720.0 | 0 | 2955575 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.1.1 Ch | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch | Point | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 | 2955576 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.2.1 Ch | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto 3Mtr form tapping to out let via seitch) | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 | 2955577 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.2.3 Ch | Point wiring using Copper wire with swith supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2x1,5sq mm Cable conforming to the GTP with 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box the other end of the wires shall be terminated with suffcient loose lenght in a wood./PVC round block complete for each outlet GROUPA short point upto6Mtr form tapping to out let via seitch | Each | 555.0 | 555.0 | 4.0 | False | None | None | False | None | False | 2220.0 | 0 | 2955578 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 11.3.1 Ch | g of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burninghours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CEapproved. 2 years Warranty against any manufacturing defectworking under standard electrical condition.LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 3.0 | False | None | None | False | None | False | 1653.0 | 0 | 2955579 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 2.3.1 Ch | Wiring for lighting/power circuit using one of FRLS PVC onsulated 1100V grade, multis and Copper conductor single core in open or consealed system of wiring. Using Class 'A' approved materials | m | 42.0 | 42.0 | 70.0 | False | None | None | False | None | False | 2940.0 | 0 | 2955580 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 3.1.2 | Supplying 6A flush/projected type socket and a 6amps flush/ projected type SP switch either surface/flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required.6Amps 3/5 way Chapter 3) | Each | 147.0 | 147.0 | 2.0 | False | None | None | False | None | False | 294.0 | 0 | 2955581 | 97685 | None | SR23-24 ELECTRIFICATION Vol 6 page No3.10Chapter | Supplying4mmthickplasticsheetwithnecessrynitchesforfixingswitches,regulations etc, and fixing on existing wooden or metal box using N.F screws | Sq CM | 1500.0 | 1500.0 | 0.41 | False | None | None | False | None | False | 615.0 | 0 | 2955582 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 pageNo 6.3Chapte | Supplyingcapacitortypecellingfancompletewithdownroadblades,shakle,canopiesetc., for operating on 230 Volts, 50Cycles. Single fase AC supplyconforming to ISS- 374-1979 & with double ball bearing system. 48"Sweep(1200)mmRegularmodel(khaitan,coromptongreaves,orientpolar,bajaj,Usha,Havells,Almonard(P.No.23,I.No. 23 (1) (a)) | No | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 | 2955583 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 5.17.1C | Supplying and fixing minitaure circuit breakers on existing MCB distribution board using necessary fixing materials and "C" Type curve, indic wiring complete as required. Indicator ON\OFF, energy cross 3 with short corcuit breaking of 10k and Complete wiring as required) | Each | 759.0 | 759.0 | 2.0 | False | None | None | False | None | False | 1518.0 | 0 | 2955584 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 5.18.1Ch | Supplying and fixing regular MCB distribution boards on wall / wood board/ flush mounting using required clamps, bolts, nuts etc., with provisionforfixingsuitabletypecapacityMCB'ssinglephase/3phase/single door with powder coated painting etc., complete. Double doo | No | 1241.0 | 1241.0 | 2.0 | False | None | None | False | None | False | 2482.0 | 0 | 2955585 | 97685 | None | SR 23-24ELECTRIFICATION Vol 6 page No2.11Chapter | Supplying, fixing & wiring, earth electrode for ground conduits. I.C. cutouts and other equipements, on the meter board using 40mm dia 2.90 thick of GI pipe 2.5 mtr long burid in a pit. The pit sholud be gilled with equal pro[ortion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per clause 7.3.3 of is 732 using 12mm dia bolts, nuts, washers, & check nut etc., The pipe shall have 16 through holes of 12mm dia | Point | 285.0 | 285.0 | 3.0 | False | None | None | False | None | False | 855.0 | 0 | 2955586 | 97685 | None | SR 2021-22 ELECTRIFICATION Vol 6 page No2.1.3 Ch | Supplying, fixing & wiring, earth electrode for ground conduits. I.C. cutouts and other equipements, on the meter board using 40mm dia 2.90 thick of GI pipe 2.5 mtr long burid in a pit. The pit sholud be gilled with equal pro[ortion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per clause 7.3.3 of is 732 using 12mm dia bolts, nuts, washers, & check nut etc., The pipe shall have 16 through holes of 12mm dia Medium point above 3m upto 6 m from tapping to out let via switch 2 | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 2955587 | 97685 | None | SR 2021-22 ELECTRIFICATION Vol 6 page No2.1.4Cha | Supplying and fixing regular MCB distribution boards on wall / wood board/ flush mounting using required clamps, bolts, nuts etc., with provisionforfixingsuitabletypecapacityMCB'ssinglephase/3phase/single door with powder coated painting etc., complete. Double doorLong point above 6m upto 10 m from tapping to out let via switch | Point | 570.0 | 570.0 | 1.0 | False | None | None | False | None | False | 570.0 | 0 | 2955588 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No2.1.4Chapt | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps nails guttas/spacers etc. GI wire | m | 17.0 | 17.0 | 100.0 | False | None | None | False | None | False | 1700.0 | 0 | 2955589 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.6 Chap | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" x12"x3"(300x300x76mm) | Each | 120.0 | 120.0 | 2.0 | False | None | None | False | None | False | 240.0 | 0 | 2955590 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.7 Chap | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete12" x9"x3"(300x228x76mm) | Each | 115.0 | 115.0 | 3.0 | False | None | None | False | None | False | 345.0 | 0 | 2955591 | 97685 | None | SR 23-24 ELECTRIFICATION Vol 6 page No 1.8 Cha | Supplying and Flush Mounting teak wooden box without front plank made of not less than 12 mm thick wood after due groove cutting finishing with necessary cement plastering complete 12" 10" x7"x3"(254x178x76mm) | cm | 117.0 | 117.0 | 4.0 | False | None | None | False | None | False | 468.0 | 0 |
|
|
---|