createdTs1709820324006
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3450.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-03-2024 16:00:00
tenderQueryClose12-03-2024 12:30:00
technicalBidOpen16-03-2024 16:30:00
publishedDate07-03-2024 20:20:26
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate13-03-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonTechnical Assistant
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9986183379
tenderSupplierListNone
tenderSchedule
createdTs1709820324035
version5
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT378
titleCONSTRUCTION OF MANIFOLD ROOM AND PROVIDING MGPLS SYSTEM AND DG SET FOR TRAUMA CARE CENTER CHIGATERI GENERAL HOSPITAL DAVANAGERE
descriptionCONSTRUCTION OF MANIFOLD ROOM AND PROVIDING MGPLS SYSTEM AND DG SET FOR TRAUMA CARE CENTER CHIGATERI GENERAL HOSPITAL DAVANAGERE
categoryWORKS
categoryTextWorks
ecv13800000.00
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount13800000.0
groupOverheadTotal2559.58
fileNumberTCC
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17098203240000NoneNoneBuildingsCONSTRUCTION OF MANIFOLD ROOM AND PROVIDING MGPLS SYSTEM AND DG SET FOR TRAUMA CARE CENTER CHIGATERI GENERAL HOSPITAL DAVANAGERE (BRIDGE)465790.52
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296713698145NonePWD SR 2023-24, Page no-5, Item No-1.4.1, Vol-1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. Note: Cost of De-watering upto 5percent may be added, where required assessment for dewatering shall be made as per site condition ( PWD SR 2023-24, Page no-5, Item No-1.4.1, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.84299.844.64FalseNoneNoneFalseNoneFalse1391.25760
296713798145NoneItem Code 2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately) ( PWD SR 2023-24, Page no-15, Item No-2.1.2, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7017.77017.75.57FalseNoneNoneFalseNoneFalse39088.5890
296713898145NoneItem Code 11.2Providing & fixing Structural Steel work riveted, bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications & as per directions of Engineer-in-Charge.(P.No77 I.No.11.2 of PWD SR 2023-24 Vol-2) 90 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKg140.01140.012959.94FalseNoneNoneFalseNoneFalse414421.19940
296713998145NoneItem Code 8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46 I.No. 8.33.3 of PWD SR 2023-24 Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm172.22172.2263.23FalseNoneNoneFalseNoneFalse10889.47060
17098203240000NoneNoneBuildingsCONSTRUCTION OF MANIFOLD ROOM AND PROVIDING MGPLS SYSTEM AND DG SET FOR TRAUMA CARE CENTER CHIGATERI GENERAL HOSPITAL DAVANAGERE (CIVIL WORK)1801844.79
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296714098146NoneItem Code 1.4.1Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. Note: Cost of De-watering upto 5percent may be added, where required assessment for dewatering shall be made as per site condition ( PWD SR 2023-24, Page no-5, Item No-1.4.1, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum299.83299.8343.82FalseNoneNoneFalseNoneFalse13138.55060
296714198146NoneItem Code 2.1.2Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost ofall materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formworkshall be paid separately) ( PWD SR 2023-24, Page no-15, Item No-2.1.2, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7017.697017.6924.61FalseNoneNoneFalseNoneFalse172705.35090
296714298146NoneItem Code 5.3Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ( PWD SR 2023-24, Page no-9, Item No-5.3, Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7687.997687.9934.73FalseNoneNoneFalseNoneFalse267003.89270
296714398146NoneItem Code 1.11Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ( PWD SR 2023-24, Page no-7, Item No-1.11, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum536.48536.4871.25FalseNoneNoneFalseNoneFalse38224.20
296714498146NoneItem Code 2.1.6Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers not exceeding 150mm thickness , well compacted using plate vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. (The costof steel reinforcement & formwork to be paid separately) Mix 1:2:4 Using 20 mm and down size graded crushed coarse aggregates. ( PWD SR 2023-24, Page no-15, Item No-2.1.6, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCum7735.077735.0721.36FalseNoneNoneFalseNoneFalse165221.09520
296714598146NoneItem Code 6.32Providing and constructing load bearing wall with Solid Concrete blocksof size 400x200x200mm having block density more than 1800kg/m3and minimum compressive strength of 4.00 N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005including cost of all materials, labour, scaffolding and curing, usagecharges of machinery etc complete as per specifications. ( PWD SR 2023-24, Page no-16, Item No-6.32, Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm1623.091623.09135.3FalseNoneNoneFalseNoneFalse219604.0770
296714698146NoneItem Code 8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removingscaffolding, including cost of materials, labour, curingcomplete as perspecifications and as per directions of Engineer-in-charge. ( PWD SR 2023-24, Page no-41, Item No-8.2.1, Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm365.5365.5282.22FalseNoneNoneFalseNoneFalse103151.410
296714798146NoneItem Code 11.16.1Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications & as per directions of Engineer-in-Charge. (P.No.82, I.No. 11.16.1 of PWD SR 2023-24,Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs168.5168.52900.0FalseNoneNoneFalseNoneFalse488650.00
296714898146NoneItem Code 8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46 I.No. 8.33.3 of PWD SR 2023-24 Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm172.22172.22149.44FalseNoneNoneFalseNoneFalse25736.55680
296714998146NoneItem Code 7.38.1Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. :(P.No.26, I.No. 7.38.1 of PWD SR 2023-24 Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm703.75703.75120.72FalseNoneNoneFalseNoneFalse84956.70
296715098146NoneItem Code 8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46, I.No. 8.33.1 of PWD SR 2023-24 Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm195.76195.7697.44FalseNoneNoneFalseNoneFalse19074.85440
296715198146NoneItem Code 11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage chargesof machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No77 I.No.11.2 of PWD SR 2023-24 Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workKgs140.0140.0945.0FalseNoneNoneFalseNoneFalse132300.00
296715298146NoneItem Code 13.31.2Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.(P.No.59 I.No. 9.1 of PWD SR 2023-24 Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSqm558.78558.7871.25FalseNoneNoneFalseNoneFalse39813.0750
296715398146NoneItem Code 1.4.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. 20 mm nominal dia Pipes (Page no: 122, I No 13.31.2, PWD SR 2023-24, Vol-2) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMT299.83299.8320.0FalseNoneNoneFalseNoneFalse5996.60
296715498146NoneItem Code 2.11aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. Buildings (Page no: 18, I No- 2.11a, PWD SR 2023-24, Vol-1) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workTonne110837.22110837.220.237FalseNoneNoneFalseNoneFalse26268.421140
17098203240000NoneNoneBuildingsCONSTRUCTION OF MANIFOLD ROOM AND PROVIDING MGPLS SYSTEM AND DG SET FOR TRAUMA CARE CENTER CHIGATERI GENERAL HOSPITAL DAVANAGERE (ELECTRICAL WORK)4620466.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296715598147NoneItem Code2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint447.21447.215.0FalseNoneNoneFalseNoneFalse2236.050
296715698147NoneItem Code2.2.3Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workPoint654.9654.918.0FalseNoneNoneFalseNoneFalse11788.20
296715798147NoneItem Code3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.6.0 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach204.14204.1413.0FalseNoneNoneFalseNoneFalse2653.820
296715898147NoneItem Code3.3.8Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.118 Way ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach400.02400.021.0FalseNoneNoneFalseNoneFalse400.020
296715998147NoneItem Code3.14.4Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 3 pin Top ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.66102.6624.0FalseNoneNoneFalseNoneFalse2463.840
296716098147NoneItem Code3.14.10Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.16Amps switch ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach154.57154.5712.0FalseNoneNoneFalseNoneFalse1854.840
296716198147NoneItem Code3.14.4Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 3 pin Top ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach102.66102.6623.0FalseNoneNoneFalseNoneFalse2361.180
296716298147NoneItem Code3.14.5Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps Bakelite ceiling rose ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach92.0392.0323.0FalseNoneNoneFalseNoneFalse2116.690
296716398147NoneItem Code3.14.7Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps lamp holder ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach87.3287.3223.0FalseNoneNoneFalseNoneFalse2008.360
296716498147NoneItem Code5.40.2Supplying .....amps rated 3phase with neutral bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary botls,nuts and washers 250Amps 4x30x10mm Alluminium Strips ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr4053.294053.293.0FalseNoneNoneFalseNoneFalse12159.870
296716598147NoneItem Code11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, deliveringsuperior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percent, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistanceof complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection Min 5KV along with Over voltage/Overload, short circuit/ miss wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LEDLight fixture with70W System power consumption.LED Efficiency greater than 130lm per w, nominal CRI greater than75. Luminaire manufacturer should have in house facility accredited by NABL/CPRI and any Government certified agency and Design and Development facility certified by ISO 9001 2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia /Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach7070.557070.552.0FalseNoneNoneFalseNoneFalse14141.10
296716698147NoneItem Code11.3.2Supplying of feet PVC Batten with integrated LED tube w with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI greater than 80.Power Input 220 to240V at 50 to 60Hz and Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1feet x4feet 20 to 22 w ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach814.19814.199.0FalseNoneNoneFalseNoneFalse7327.710
296716798147NoneItem Code13.1.2Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV /MH /FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts ,nuts and wiring using suitable capacity wires. Using 32mm dia G.I.pipe ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1233.11233.15.0FalseNoneNoneFalseNoneFalse6165.50
296716898147NoneItem Code13.7.1Fixing all types and all capacities of flurescent/ flase ceiling / spot light/ CFL/ LED fittings indoor on the wall / celling / rafters / griders using 23/0.0076" twin rwisted PVC insulated wires, required Nos of round blocks and clamps. On wall / celling / rafter / griders ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach143.95143.9517.0FalseNoneNoneFalseNoneFalse2447.150
296716998147NoneItem Code32.091.1 kV, XLPE or Heat resistant PVCinsulated, PVC exutruted Inner SeathArmoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-39753.5 core 35 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workCoil181793.16181793.160.1FalseNoneNoneFalseNoneFalse18179.3160
296717098147NoneItem Code5.18.1Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.6-32 A SP ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach489.7489.74.0FalseNoneNoneFalseNoneFalse1958.80
296717198147NoneItem Code5.18.6Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.50-63 A TPN ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach1300.361300.361.0FalseNoneNoneFalseNoneFalse1300.360
296717298147NoneItem Code5.20.10Supplying, fixing and wiring Residual current circuit breaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board.63 A 4 pole ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach6543.096543.091.0FalseNoneNoneFalseNoneFalse6543.090
296717398147NoneItem Code51.01GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo879.74879.746.0FalseNoneNoneFalseNoneFalse5278.440
296717498147NoneItem Code51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kgeach ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNo797.68797.686.0FalseNoneNoneFalseNoneFalse4786.080
296717598147NoneItem Code51.03GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long,3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 Kg ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workBag365.8365.86.0FalseNoneNoneFalseNoneFalse2194.80
296717698147NoneItem Code5.18.9Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.. II - Double Door 12Way SP &N ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach2748.222748.221.0FalseNoneNoneFalseNoneFalse2748.220
296717798147NoneItem Code6.2.1Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 12" Sweep (300mm) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workEach3503.413503.414.0FalseNoneNoneFalseNoneFalse14013.640
296717898147NoneItem Code2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 1.5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr30.6830.6875.0FalseNoneNoneFalseNoneFalse2301.00
296717998147NoneItem Code2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 2 .5 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr49.5549.5550.0FalseNoneNoneFalseNoneFalse2477.50
296718098147NoneItem Code2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments 4 .0 sqmm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr74.3374.33100.0FalseNoneNoneFalseNoneFalse7433.00
296718198147NonePWD SR 2023-24, Page no-3, Item No-1.8.3, Vol-6Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm 30MM …. Etc as required. ( PWD SR 2023-24, Page no-3, Item No-1.8.3, Vol-6) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr50.7450.7475.0FalseNoneNoneFalseNoneFalse3805.50
296718298147NonePWD SR 2023-24, Page no-42, Item No 10.1.16 VolSupplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. Engine Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10 percent for one hour in 12 hours of operation Capacity of Fuel Tank Fuel tank suitable for 8 hours of operation Alternator Alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 pf lag suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator 500 KVA/400 kw etc., complete with all lead & lift, as per specifications and a per directions of the Engineer in charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet4477322.384477322.381.0FalseNoneNoneFalseNoneFalse4477322.380
17098203240000NoneNoneBuildingsCONSTRUCTION OF MANIFOLD ROOM AND PROVIDING MGPLS SYSTEM AND DG SET FOR TRAUMA CARE CENTER CHIGATERI GENERAL HOSPITAL DAVANAGERE (MGPLS WORKS)6909338.65
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296718398148NoneItem Code 1Oxygen Manifold: Main 10+10 Cylinder Oxygen Manifold Should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames Should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 pig ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet128915.0128915.01.0FalseNoneNoneFalseNoneFalse128915.00
296718498148NoneItem Code 2Micro process based Automatic High flow upto 2100 ltrs per min Oxygen Control Panel. 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrate plant 4.1 kg per sqcm (Future Provision) Working Pressure from fully automatic control panel. 4.1 kg per cm 2 Working Pressure from Emergency manifold system 4.1 kg per sqcm Changeover unit of all 3 sources Should be at the pressure from oxygen concentrator plant Below 4.1kg per sqcm Changeover unit of all 3 sources Should be at the pressure from main Manifold system Below 4.1kg per sqcm Changeover unit of all 3 sources Should be at the pressure from Emergency manifold system Below 4.1kg per sqcm The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. All the electrical circuits Should be operated at 12 volts and 24 volts with provision of inbuilt power conversion equipment. The Pannel shall have the necessary instruments, gauges, LED Indicators etc complete with Separate indicators for from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure. Left bank Green signal for Normal Pressure and Red for Low pressure. In Right bank Green signal for Normal Pressure and Red for Low pressure. In Emergency manifold Green signal for Normal Pressure and Red for Low pressure. Main Line Green signal for Normal Pressure and Red for Low pressure ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet218300.0218300.01.0FalseNoneNoneFalseNoneFalse218300.00
296718598148NoneItem Code 3Oxygen Manifold System Emergency. The Control panel shall be of fully integrated type with all safety futures inbuilt for high pressure and high flow upto 2200 ltrs per min Oxygen system. 2 plus 2 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg per sqcm and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold.Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. Semi automatic control panel. Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows   Control panel shall be made of M.S.duly powder coated. Easy maintenance.   Highly reliable.  Designed for safety and continuity of flow supply at a constant pressure. Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure.  Capable to provide a distribution flow rate in excess of 1500LPM. Should have Incorporation of safety features in case pressure exceeds 100Psi. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet94990.094990.01.0FalseNoneNoneFalseNoneFalse94990.00
296718698148NoneItem Code 4Nitrous Oxide Main Manifold System Supply, Installation, Testing and commissioning of 2 cylinder (1 plus 1) Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg per sqcmHigh Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
296718798148NoneItem Code 5VACCUM SUPPLY SYSTEM COMPLETE IN ALL RESPECT with receiver tank The pump installation shall be duplex system consisting of two (1W plus1S BY) identical rotary vane pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 3276 LPM (200cum per h) i.e 117 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg . The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022 HTM 02 01 conforms to IEC Standards manufactured in accordance with HTM 2022 HTM 02 01 conforms to IEC Standards Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply. Each pump shall have a built in non return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system. Pump should be of reputed make as per international standards. The control panel shall consist of three separate. Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable.The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 1500 Liter or as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two component coating to provide a hard, durable lining for rust protection. The System should provide audible and visual local and remote alarm indications for the compressor temperature malfunction and reserve compressor in use. All control and alarm functions should remain energized while any compressor remains electrically on line.The System should provide manual reset for thermal malfunction shutdown.The lag Pumps should be able to start automatically if the lead compressor fails to operate. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet949900.0949900.01.0FalseNoneNoneFalseNoneFalse949900.00
296718898148NoneItem Code 6VACUUM BACTERIAL FILTERATION, Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005percentage penetration specified in HTM2022 for infectious disease unit. i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below FAC AT Atmospheric 1850 LPM Size G 1 Bacterial Removal 0.0001percentage penetration when tested to BS 3928 ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet162840.0162840.01.0FalseNoneNoneFalseNoneFalse162840.00
296718998148NoneItem Code 7Compressed Air System System For Medical use. Type Reciprocating, Air cooled oil grease free Capacity of Piston Displacement 22.93 cfm 649 Lpm Capacity of Piston Displacement 22.93 cfm 649 Lpm Drive Belt driven No. of Air Compressors 2 Nos. (1W plus 1S by) Motor Capacity 5 HP as required Receiver Capacity 1000 liters water capacity Air reciever Receiver type Vertical type with inlet, outlet & drain provisions ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet800630.0800630.01.0FalseNoneNoneFalseNoneFalse800630.00
296719098148NoneItem Code 8Duplex Medical Air Dryer System ( Breathing Air System) (2 Nos of 1 set) 100 CFM Air Dryer Min Working Pressure should be 4 bar, Rated Inlet Pressure should be 7 bar Max Working Pressure should be 16 bar Supply Voltage Should be 100 240 VAC, 50/60 Hz, 1 Ph Rated Inlet temperature should be 38 deg C Dryer capable to give should be 40 PDP Purge Loss 15 percent Air quality As per NFPA 99 Dual System Three stage filter (Dessicated drier) CO and Dew point level as per NFPA 99 Bacterial Penetration 0.00001percent Failure Indication Purge Saving control Manual No refrigerant used Energy saving Dew point based dryer cycling. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet88205.088205.01.0FalseNoneNoneFalseNoneFalse88205.00
296719198148NoneItem Code 9DUPLEX COMPRESSED AIR BREATHING FILTERATION SYSTEM 3 STAGE .The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3 stages of filters Shouldbe used as mentioned below Stage 1 Oil aerosol contents removal up to 0.5 mg per cum. Stage 2 Oil aerosol contents removal up to 0.01 mg per cum. Stage 3 Oil content removal up to 0.003 mg per cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch I Standard. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workSet67850.067850.01.0FalseNoneNoneFalseNoneFalse67850.00
296719298148NoneItem Code 10Air Cooler Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos81420.081420.01.0FalseNoneNoneFalseNoneFalse81420.00
296719398148NoneItem Code 11Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 54mm. OD x 1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr4854.514854.51100.0FalseNoneNoneFalseNoneFalse485451.00
296719498148NoneItem Code 12Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 42mm. ODx1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr3608.433608.4355.0FalseNoneNoneFalseNoneFalse198463.650
296719598148NoneItem Code 13Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 35mm. ODx1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr2570.042570.0480.0FalseNoneNoneFalseNoneFalse205603.20
296719698148NoneItem Code 14Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 28mm. ODx1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr1492.691492.69220.0FalseNoneNoneFalseNoneFalse328391.80
296719798148NoneItem Code 15Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 22mm. ODx1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr1156.391156.39600.0FalseNoneNoneFalseNoneFalse693834.00
296719898148NoneItem Code 16Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 15mm. OD x 1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr949.9949.9600.0FalseNoneNoneFalseNoneFalse569940.00
296719998148NoneItem Code 17Copper Fittings Supply, Installation, Testing and Commissioning All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BSEN 133482001 plus A12005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.Copper Pipe 12mm. OD x1.2 mm.thick. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workMtr651.36651.36200.0FalseNoneNoneFalseNoneFalse130272.00
296720098148NoneItem Code 18OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes). Oxygen Terminals drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3392.53392.550.0FalseNoneNoneFalseNoneFalse169625.00
296720198148NoneItem Code 19OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes).Vacuum Terminal drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3392.53392.547.0FalseNoneNoneFalseNoneFalse159447.50
296720298148NoneItem Code 20OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes).Compressed Air Terminals 4 Bar drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3392.53392.54.0FalseNoneNoneFalseNoneFalse13570.00
296720398148NoneItem Code 21OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes). Compressed Air Terminals 7 Bar drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3392.53392.52.0FalseNoneNoneFalseNoneFalse6785.00
296720498148NoneItem Code 22OUTLET POINTS Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes). Nitous Oxide Terminals drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3392.53392.52.0FalseNoneNoneFalseNoneFalse6785.00
296720598148NoneItem Code 23ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES. Oxygen Flow meter with Humidifier Bottle. Flow meter should be Backpressure Compensated. Flow meter should be accurate gas flow measurement and control within a range of 0 15 liters per minute. It should meet strict precision and durability standards. Flow meter body should be made of brass material. Flow tube and shroud components should be made of clear, impact resistant polycarbonate. The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier should have built in safety valve. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos2849.72849.754.0FalseNoneNoneFalseNoneFalse153883.80
296720698148NoneItem Code 24Single piece wall mounted suction collection & regulation unit. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3528.23528.247.0FalseNoneNoneFalseNoneFalse165825.40
296720798148NoneItem Code 25Theatre Vacuum Unit The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade. Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either.Left, Right or Both . All the above items Should be mounted on a Trolley having a free moving castor wheels. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos16962.516962.52.0FalseNoneNoneFalseNoneFalse33925.00
296720898148NoneItem Code 26ISOLATION VALVES Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction. Isolation Valves 54 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos8814.68814.62.0FalseNoneNoneFalseNoneFalse17629.20
296720998148NoneItem Code 27ISOLATION VALVES Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction. Isolation Valves 42 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos8142.08142.07.0FalseNoneNoneFalseNoneFalse56994.00
296721098148NoneItem Code 28ISOLATION VALVES Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction. Isolation Valves 35 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos5428.05428.09.0FalseNoneNoneFalseNoneFalse48852.00
296721198148NoneItem Code 29ISOLATION VALVES Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction. Isolation Valves 28 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos4071.04071.012.0FalseNoneNoneFalseNoneFalse48852.00
296721298148NoneItem Code 30ISOLATION VALVES Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction. Isolation Valves 22 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos3392.53392.518.0FalseNoneNoneFalseNoneFalse61065.00
296721398148NoneItem Code 31ISOLATION VALVES Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction. Isolation Valves 15 mm ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos2714.02714.040.0FalseNoneNoneFalseNoneFalse108560.00
296721498148NoneItem Code 32Zonal Valve box three Gas services An Zonal area valve box should have bellow spec. .Wall mounted M.S. box with powder coated & lockable, front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position. The valve box door cannot be close during valve close position. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos18319.518319.53.0FalseNoneNoneFalseNoneFalse54958.50
296721598148NoneItem Code 33Zonal Valve box five Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable,   front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position. The valve box door cannot be close during valve close position. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos23364.023364.02.0FalseNoneNoneFalseNoneFalse46728.00
296721698148NoneItem Code 34Digital Area Alarm for Three Gas Systems Micro processor controlled Area Gas alarm panel five Lines, Should audio visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos35282.035282.03.0FalseNoneNoneFalseNoneFalse105846.00
296721798148NoneItem Code 35Digital Area Alarm for Five Gas Systems Micro processor controlled Area Gas alarm panel five Lines, Should audio visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos47495.047495.02.0FalseNoneNoneFalseNoneFalse94990.00
296721898148NoneItem Code 36Bed Headed Panel and Railing. 1.5M Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6 per 16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets. Provision Medical Gas Terminal Units as follows.  2.1 Two oxygen outlet. 2.2  One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos36639.036639.08.0FalseNoneNoneFalseNoneFalse293112.00
296721998148NoneItem Code 37Conversion Kit for Anesthesia for Oxygen. Should have high pressure antistatic tubing which is color coded. etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1899.81899.81.0FalseNoneNoneFalseNoneFalse1899.80
296722098148NoneItem Code 38Conversion Kit for Anesthesia for Nitrous Oxide. Should have high pressure antistatic tubing which is color coded Etc.complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the workNos1899.81899.81.0FalseNoneNoneFalseNoneFalse1899.80
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17098203270000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17098203270001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17098203270001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17098204100000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17098204190000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17098204280000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17098204380000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17098204480000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17098204580000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete mannerNone
17098204670000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17098204750000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17098204840000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17098204940000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17098205080000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17098205170000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17098205290000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17098205390000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17098205480000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17098205590000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17098205680000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17098205780000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17098205860000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17098205940000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2023-24.None
17098206050000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsiveNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23)as a prime Contractor. The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.69.00 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2018-19 to 2022-23)as a prime contractor. Clause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.23.00 Lakhs in any one year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not less than the rank of Executive Engineer
NoneNoneNoneNoneClause 3.2(e) The Tenderer or his identified Sub Contractor should have executed similar building MGPLS works totaling to Rs.35.00lakhs in any one year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/autonomous bodies of Government will be considered for the clause 3.2 (e).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not less than the rank of Executive Engineer
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e. (2018-19 to 2022-23)as a prime contractor. Clause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23). Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 39.00Cum, 2)RCC and PCC 41.00 Cum 3)Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall 108.00Sqmtr, 5)Plastering 226.00Sqm, 6)Painting 248.00Sqmtr.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done certificate issued by the officer not less than the rank of Executive Engineer
NoneNoneNoneNoneKPWD Class-III & Above Registration CertificateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level of existing commitments and ongoing works to be completed during the next 03 months. Note The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneTo qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e. (2018-19 to 2022-23)as a prime contractor. Clause ITT 3.2(a)The tenderer should have been achieved in at least two financial years a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.276.00 Lakhs.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.42.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
KPWD Class-III & Above Registration Certificate issued by Chief Engineer PWD.TrueTechnical Bid
GST CertificateTrueTechnical Bid
ESI & EPF CertificateTrueTechnical Bid
Work done Certificate issued by the officer not lessthan the rank of Executive EngineerTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709822634000
version0
createdDateNone
modifiedDateNone
blockNumberArogya Soudha, 3rd Floor, Leprosy Hospital Premises
streetNone
cityBengaluru
stateKarnataka
pin560023
tenderRecallDTONone