2905693 | 95424 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work etc.., complete and as directed by the Engineer-in-charge. | Cum | 76.65 | 76.65 | 464.82 | False | None | None | False | None | False | 35628.453 | 0 |
2905694 | 95424 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. | Cum | 5831.7 | 5831.7 | 20.21 | False | None | None | False | None | False | 117858.657 | 0 |
2905695 | 95424 | None | code03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Footings | Cum | 6595.16 | 6595.16 | 124.51 | False | None | None | False | None | False | 821163.3716 | 0 |
2905696 | 95424 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Columns and Curtain Wall | Cum | 6783.59 | 6783.59 | 26.99 | False | None | None | False | None | False | 183089.0941 | 0 |
2905697 | 95424 | None | code05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Plinth Beam | Cum | 9421.65 | 9421.65 | 10.86 | False | None | None | False | None | False | 102319.119 | 0 |
2905698 | 95424 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Columns | Cum | 11042.01 | 11042.01 | 7.97 | False | None | None | False | None | False | 88004.8197 | 0 |
2905699 | 95424 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Lintle, Beams, | Cum | 10392.48 | 10392.48 | 18.94 | False | None | None | False | None | False | 196833.5712 | 0 |
2905700 | 95424 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Roof | Cum | 9742.95 | 9742.95 | 39.14 | False | None | None | False | None | False | 381339.063 | 0 |
2905701 | 95424 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. Chajja And Stair Case | Cum | 9418.19 | 9418.19 | 6.22 | False | None | None | False | None | False | 58581.1418 | 0 |
2905702 | 95424 | None | code10 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)etc.., complete and as directed by the Engineer-in-charge. | Kg | 96.6 | 96.6 | 17858.9 | False | None | None | False | None | False | 1725169.74 | 0 |
2905703 | 95424 | None | code11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m etc.., complete and as directed by the Engineer-in-charge. | Cum | 214.2 | 214.2 | 293.12 | False | None | None | False | None | False | 62786.304 | 0 |
2905704 | 95424 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work etc.., complete and as directed by the Engineer-in-charge. | Cum | 7024.5 | 7024.5 | 65.43 | False | None | None | False | None | False | 459613.035 | 0 |
2905705 | 95424 | None | code13 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work etc.., complete and as directed by the Engineer-in-charge. | Sqm | 863.1 | 863.1 | 68.34 | False | None | None | False | None | False | 58984.254 | 0 |
2905706 | 95424 | None | code14 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all others appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates etc.., complete and as directed by the Engineer-in-charge. | Cum | 7408.8 | 7408.8 | 1.98 | False | None | None | False | None | False | 14669.424 | 0 |
2905707 | 95424 | None | code15 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications etc.., complete and as directed by the Engineer-in-charge. | Cum | 79111.2 | 79111.2 | 0.78 | False | None | None | False | None | False | 61706.736 | 0 |
2905708 | 95424 | None | code16 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) etc.., complete and as directed by the Engineer-in-charge. | Sqm | 5327.7 | 5327.7 | 19.38 | False | None | None | False | None | False | 103250.826 | 0 |
2905709 | 95424 | None | code17 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications etc.., complete and as directed by the Engineer-in-charge. | No | 1559.25 | 1559.25 | 8.0 | False | None | None | False | None | False | 12474.0 | 0 |
2905710 | 95424 | None | code18 | Providing and fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL 9016) sections and with minimum TiO2 (Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame.The outer frame having an overall size of 44mm width x 40mm height with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) etccomplete and as directed by the Engineer in-charge. | Sqm | 4319.7 | 4319.7 | 18.63 | False | None | None | False | None | False | 80476.011 | 0 |
2905711 | 95424 | None | code19 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.., complete and as directed by the Engineer-in-charge. | Kg | 166.95 | 166.95 | 476.28 | False | None | None | False | None | False | 79514.946 | 0 |
2905712 | 95424 | None | code20 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc.., complete and as directed by the Engineer-in-charge. | Sqm | 223.65 | 223.65 | 707.29 | False | None | None | False | None | False | 158185.4085 | 0 |
2905713 | 95424 | None | code21 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing etc.., complete and as directed by the Engineer-in-charge. | Sqm | 241.5 | 241.5 | 265.52 | False | None | None | False | None | False | 64123.08 | 0 |
2905714 | 95424 | None | code22 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labouretc.., complete and as directed by the Engineer-in-charge. | Sqm | 87.0 | 87.0 | 909.79 | False | None | None | False | None | False | 79151.73 | 0 |
2905715 | 95424 | None | code23 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 69.3 | 69.3 | 265.52 | False | None | None | False | None | False | 18400.536 | 0 |
2905716 | 95424 | None | code24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. **Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 3025.05 | 3025.05 | 233.97 | False | None | None | False | None | False | 707770.9485 | 0 |
2905717 | 95424 | None | code25 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I.pipes including cost of materials, labour, usage charges of machinery complete as per pecifications and as per directions of the Engineerin-Charge. | Kg | 154.35 | 154.35 | 177.98 | False | None | None | False | None | False | 27471.213 | 0 |
2905718 | 95424 | None | code26 | Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge. | Sqm | 144.9 | 144.9 | 42.74 | False | None | None | False | None | False | 6193.026 | 0 |
2905719 | 95424 | None | code27 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 mover an under coat of primer applied @0.75 ltr/10 mof approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 110.25 | 110.25 | 19.38 | False | None | None | False | None | False | 2136.645 | 0 |
2905720 | 95424 | None | code28 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specifications and as per directions of Engineer-in-charge. Columns | Cum | 11145.22 | 11145.22 | 7.29 | False | None | None | False | None | False | 81248.6538 | 0 |
2905721 | 95424 | None | code29 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specifications and as per directions of Engineer-in-charge. Lintle, Beams | Cum | 10489.62 | 10489.62 | 18.94 | False | None | None | False | None | False | 198673.4028 | 0 |
2905722 | 95424 | None | code30 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specifications and as per directions of Engineer-in-charge. Roof | Cum | 9834.02 | 9834.02 | 39.14 | False | None | None | False | None | False | 384903.5428 | 0 |
2905723 | 95424 | None | code31 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates complete as per specifications and as per directions of Engineer-in-charge. Chajja And Stair Case | Cum | 9501.73 | 9501.73 | 4.52 | False | None | None | False | None | False | 42947.8196 | 0 |
2905724 | 95424 | None | code32 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)complete as per specifications and as per directions of Engineer-in-charge. | Kg | 97.57 | 97.57 | 10428.19 | False | None | None | False | None | False | 1017478.4983 | 0 |
2905725 | 95424 | None | code33 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7094.74 | 7094.74 | 66.64 | False | None | None | False | None | False | 472793.4736 | 0 |
2905726 | 95424 | None | code34 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 871.73 | 871.73 | 42.5 | False | None | None | False | None | False | 37048.525 | 0 |
2905727 | 95424 | None | code35 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all others appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates complete as per the direction of engineer incharge of work. | Cum | 7482.89 | 7482.89 | 1.92 | False | None | None | False | None | False | 14367.1488 | 0 |
2905728 | 95424 | None | code36 | Providing & fixing of 2track x 2panel sliding windows made out of multi chambered UPVC (Matching to RAL9016) sections and with minimum TiO2 (Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame.The outer frame having an overall size of 44mm width x 40mm height with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) complete as per the direction of engineer incharge of work. | Sqm | 4362.9 | 4362.9 | 18.63 | False | None | None | False | None | False | 81280.827 | 0 |
2905729 | 95424 | None | code37 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.complete as per the direction of engineer incharge of work. | Sqm | 168.62 | 168.62 | 253.26 | False | None | None | False | None | False | 42704.7012 | 0 |
2905730 | 95424 | None | code38 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. etc.complete as per the direction of engineer incharge of work. 19/20mm dia 2mm thick | Mtr | 68.0 | 68.0 | 250.0 | False | None | None | False | None | False | 17000.0 | 0 |
2905731 | 95424 | None | code39 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws etc.complete as per the direction of engineer incharge of work. 25mm dia 2mm thick. | Mtr | 80.0 | 80.0 | 350.0 | False | None | None | False | None | False | 28000.0 | 0 |
2905732 | 95424 | None | code40 | Concealed PVC Conduit. Supplying Heavy Gauge PVC Conduit pipe ……dia......mm dia thick confirming to IS 2059 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. Make;Sudhakar Polimers Limited.etc.complete as per the direction of engineer incharge of work. 19/20mm dia 2mm thick | Mtr | 61.0 | 61.0 | 250.0 | False | None | None | False | None | False | 15250.0 | 0 |
2905733 | 95424 | None | code41 | Concealed PVC Conduit. Supplying Heavy Gauge PVC Conduit pipe ……dia......mm dia thick confirming to IS 2059 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. Make;Sudhakar Polimers Limited. .etc.complete as per the direction of engineer incharge of work. 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 350.0 | False | None | None | False | None | False | 24500.0 | 0 |
2905734 | 95424 | None | code42 | Groove cutting in the wall supplying Heavy Gauge PVC Conduit pipe ……dia......mm thick heavy guage PVC conduit pipe with sutable size bends, metal junction boxes, adhesive paste etc.by groove cutting in the wall and fixing by using U og J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.etc.complete as per the direction of engineer incharge of work 19/20mm dia 2mm thick | Mtr | 75.0 | 75.0 | 250.0 | False | None | None | False | None | False | 18750.0 | 0 |
2905735 | 95424 | None | code43 | Groove cutting in the wall supplying Heavy Gauge PVC Conduit pipe ……dia......mm thick heavy guage PVC conduit pipe with sutable size bends, metal junction boxes, adhesive paste etc.by groove cutting in the wall and fixing by using U og J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary etc.., complete and as directed by the Engineer-in-charge. 25mm dia 2mm thick. | Mtr | 80.0 | 80.0 | 350.0 | False | None | None | False | None | False | 28000.0 | 0 |
2905736 | 95424 | None | code44 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.., complete and as directed by the Engineer-in-charge. 75 x 75 x 65 mm, | No | 100.0 | 100.0 | 10.0 | False | None | None | False | None | False | 1000.0 | 0 |
2905737 | 95424 | None | code45 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.., complete and as directed by the Engineer-in-charge. . 100 x 75 x 65 mm | No | 112.0 | 112.0 | 10.0 | False | None | None | False | None | False | 1120.0 | 0 |
2905738 | 95424 | None | code46 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.., complete and as directed by the Engineer-in-charge. .135 x 75 x 65 mm | No | 131.0 | 131.0 | 10.0 | False | None | None | False | None | False | 1310.0 | 0 |
2905739 | 95424 | None | code47 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.., complete and as directed by the Engineer-in-charge. .180 x 90 x 65 mm, | No | 155.0 | 155.0 | 25.0 | False | None | None | False | None | False | 3875.0 | 0 |
2905740 | 95424 | None | code48 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.., complete and as directed by the Engineer-in-charge. .200 x 90 x 65 mm, | No | 169.0 | 169.0 | 10.0 | False | None | None | False | None | False | 1690.0 | 0 |
2905741 | 95424 | None | code49 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.., complete and as directed by the Engineer-in-charge. .35 x 160 x 65 mm, | No | 169.0 | 169.0 | 8.0 | False | None | None | False | None | False | 1352.0 | 0 |
2905742 | 95424 | None | code50 | Supplying and fixing PVC/metal conduit accessories Deep junction box 19 /20mmdia deep Junction Box etc.., complete and as directed by the Engineer-in-charge. | No | 49.0 | 49.0 | 45.0 | False | None | None | False | None | False | 2205.0 | 0 |
2905743 | 95424 | None | code51 | Supplying and fixing PVC/metal conduit accessories Deep junction box 25 mm dia deep Junction Box etc.., complete and as directed by the Engineer-in-charge. | No | 81.0 | 81.0 | 40.0 | False | None | None | False | None | False | 3240.0 | 0 |
2905744 | 95424 | None | code52 | Supplyin And Fixing Metal Fan Box with Round Hook etc.., complete and as directed by the Engineer-in-charge. . | No | 163.0 | 163.0 | 18.0 | False | None | None | False | None | False | 2934.0 | 0 |
2905745 | 95424 | None | code53 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With low conductor resistance single core cable in open or concealed system of wiring with specified IS 694:1990 & Conforming to GTP of GROUP-A etc.., complete and as directed by the Engineer-in-charge. 1.5 sqmm | Mtr | 26.0 | 26.0 | 1500.0 | False | None | None | False | None | False | 39000.0 | 0 |
2905746 | 95424 | None | code54 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With low conductor resistance single core cable in open or concealed system of wiring with specified IS 694:1990 & Conforming to GTP of GROUP-A etc.., complete and as directed by the Engineer-in-charge. 2.50 sqmm | Mtr | 40.0 | 40.0 | 1450.0 | False | None | None | False | None | False | 58000.0 | 0 |
2905747 | 95424 | None | code55 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper With low conductor resistance single core cable in open or concealed system of wiring with specified IS 694:1990 & Conforming to GTP of GROUP-A etc.., complete and as directed by the Engineer-in-charge. 4.00 sqmm | Mtr | 59.0 | 59.0 | 650.0 | False | None | None | False | None | False | 38350.0 | 0 |
2905748 | 95424 | None | code56 | Supplying 6A flush type socket and a 6 amps flush type SP switch either surface /flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. etc.., complete and as directed by the Engineer-in-charge. 6Amps 2 Way | Each | 112.0 | 112.0 | 14.0 | False | None | None | False | None | False | 1568.0 | 0 |
2905749 | 95424 | None | code57 | Supplying 6A flush type socket and a 6 amps flush type SP switch either surface /flush mounting in a existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654. etc.., complete and as directed by the Engineer-in-charge. 6Amps 3/5 Way | Each | 132.0 | 132.0 | 12.0 | False | None | None | False | None | False | 1584.0 | 0 |
2905750 | 95424 | None | code58 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293. etc.., complete and as directed by the Engineer-in-charge. 6Amps one way switch | Each | 70.0 | 70.0 | 30.0 | False | None | None | False | None | False | 2100.0 | 0 |
2905751 | 95424 | None | code59 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293. etc.., complete and as directed by the Engineer-in-charge. 6Amps two way switch | Each | 95.0 | 95.0 | 25.0 | False | None | None | False | None | False | 2375.0 | 0 |
2905752 | 95424 | None | code60 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293. etc.., complete and as directed by the Engineer-in-charge. 6Amps 3 way socket | Each | 105.0 | 105.0 | 12.0 | False | None | None | False | None | False | 1260.0 | 0 |
2905753 | 95424 | None | code61 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293. etc.., complete and as directed by the Engineer-in-charge. 16Amps one way switch | Each | 115.0 | 115.0 | 18.0 | False | None | None | False | None | False | 2070.0 | 0 |
2905754 | 95424 | None | code62 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293. etc.., complete and as directed by the Engineer-in-charge. 32Amps DP switch | Each | 182.0 | 182.0 | 16.0 | False | None | None | False | None | False | 2912.0 | 0 |
2905755 | 95424 | None | code63 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293. etc.., complete and as directed by the Engineer-in-charge. 6/16 Amps universal socket | Each | 162.0 | 162.0 | 14.0 | False | None | None | False | None | False | 2268.0 | 0 |
2905756 | 95424 | None | code64 | Supplying and fixing of modular switch & conncted accessories on existing modular swicth plate as per per IS 3854 and IS 1293 etc.., complete and as directed by the Engineer-in-charge. 16Amp sone way switch | Each | 115.0 | 115.0 | 8.0 | False | None | None | False | None | False | 920.0 | 0 |
2905757 | 95424 | None | code65 | Electronic stepped fan regulator etc.., complete and as directed by the Engineer-in-charge. | No | 205.0 | 205.0 | 12.0 | False | None | None | False | None | False | 2460.0 | 0 |
2905758 | 95424 | None | code66 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws. etc.., complete and as directed by the Engineer-in-charge. | Sqm | 0.27 | 0.27 | 5000.0 | False | None | None | False | None | False | 1350.0 | 0 |
2905759 | 95424 | None | code67 | Extra for supplying 4mm thcik white plastic plate and covering for junction boxes or size 80mm mm conduit using necessary machine screws. make, etc.., complete and as directed by the Engineer-in-charge. | No | 9.0 | 9.0 | 150.0 | False | None | None | False | None | False | 1350.0 | 0 |
2905760 | 95424 | None | code68 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies, for operation on 230Volts, 50cycles, single phase AC supply conforming to ISS-374-1979 and with double ball bearing system . etc.., complete and as directed by the Engineer-in-charge. 48 " sweep regular model [1200mm] | Each | 2090.0 | 2090.0 | 20.0 | False | None | None | False | None | False | 41800.0 | 0 |
2905761 | 95424 | None | code69 | Supplying and fixing using a mm dia class A GI pipe bracket upto 2.0 mtrs long bent at suitable and fixing to this bracket 1x40w/2x40w fluirescent tubes street light fittings of all capacities to GI or CI or rail OR RCC pole /wall using suitable clamps, bolts and nuts, and wiring using suitable capacity wires. etc.., complete and as directed by the Engineer-in-charge. Using 25mm dia G.I Pipe | Each | 775.0 | 775.0 | 4.0 | False | None | None | False | None | False | 3100.0 | 0 |
2905762 | 95424 | None | code70 | Supplying and fixing using a mm dia class A GI pipe bracket upto 2.0 mtrs long bent at suitable and fixing to this bracket 1x40w/2x40w fluirescent tubes street light fittings of all capacities to GI or CI or rail OR RCC pole /wall using suitable clamps, bolts and nuts, and wiring using suitable capacity wires etc.., complete and as directed by the Engineer-in-charge. .Using 32mm dia G.I Pipe | Each | 835.0 | 835.0 | 2.0 | False | None | None | False | None | False | 1670.0 | 0 |
2905763 | 95424 | None | code71 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.., complete and as directed by the Engineer-in-charge. complete on the existing metal/PVC box1-3 Module | Each | 110.0 | 110.0 | 16.0 | False | None | None | False | None | False | 1760.0 | 0 |
2905764 | 95424 | None | code72 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.., complete and as directed by the Engineer-in-charge. complete on the existing metal/PVC box4 Module | Each | 125.0 | 125.0 | 10.0 | False | None | None | False | None | False | 1250.0 | 0 |
2905765 | 95424 | None | code73 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.., complete and as directed by the Engineer-in-charge. complete on the existing metal/PVC box6 Module | Each | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 |
2905766 | 95424 | None | code74 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.., complete and as directed by the Engineer-in-charge. , complete on the existing metal/PVC box8 Module | Each | 200.0 | 200.0 | 8.0 | False | None | None | False | None | False | 1600.0 | 0 |
2905767 | 95424 | None | code75 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc.., complete and as directed by the Engineer-in-charge. complete on the existing metal/PVC box10-12 Module | Each | 230.0 | 230.0 | 8.0 | False | None | None | False | None | False | 1840.0 | 0 |
2905768 | 95424 | None | code76 | Fixing all types and all capacities Fluorescent / false ceiling /spot light/CFL/ LED fittings indoor on the wall / ceiling rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps. On wall / ceiling /rafter/girder etc.., complete and as directed by the Engineer-in-charge. | Each | 110.0 | 110.0 | 20.0 | False | None | None | False | None | False | 2200.0 | 0 |
2905769 | 95424 | None | code77 | Fixing a ceiling/ Wall mounting fan of all capacities and all types to the existing S hook, with fan regulator to the existing board together with supplying and fixing 5amps ceiling rose , necessary length of 23/0.0076 inch pvc insulated twin twisted copper wire and wiring etc.., complete and as directed by the Engineer-in-charge. | Each | 150.0 | 150.0 | 18.0 | False | None | None | False | None | False | 2700.0 | 0 |
2905770 | 95424 | None | code78 | Extra length of GI pipe of class B 19mm for down rod. etc.., complete and as directed by the Engineer-in-charge. | Each | 160.0 | 160.0 | 12.0 | False | None | None | False | None | False | 1920.0 | 0 |
2905771 | 95424 | None | code79 | Supplying and fixing of porcelain fuse channel with cut out on existing wooden/ pannel using necessary nuts, bolts and washers etc complete etc.., complete and as directed by the Engineer-in-charge. 63Amps | Each | 227.0 | 227.0 | 10.0 | False | None | None | False | None | False | 2270.0 | 0 |
2905772 | 95424 | None | code80 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board. etc.., complete and as directed by the Engineer-in-charge. 16 -25A 2 pole | Nos | 2300.0 | 2300.0 | 2.0 | False | None | None | False | None | False | 4600.0 | 0 |
2905773 | 95424 | None | code81 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. etc.., complete and as directed by the Engineer-in-charge. 12"x12"x2". | Each | 150.0 | 150.0 | 5.0 | False | None | None | False | None | False | 750.0 | 0 |
2905774 | 95424 | None | code82 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG M.S enclosure, etc.., complete and as directed by the Engineer-in-charge. Double Door 12 way SP & N | Each | 1800.0 | 1800.0 | 1.0 | False | None | None | False | None | False | 1800.0 | 0 |
2905775 | 95424 | None | code83 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia. etc.., complete and as directed by the Engineer-in-charge. | No | 2999.7 | 2999.7 | 2.0 | False | None | None | False | None | False | 5999.4 | 0 |
2905776 | 95424 | None | code84 | Labour charges for laying of 1x1 KV class UG cable in existing trench GI pipe/stoneware pipe/ on wall / on pole as required. . In Existing Trench./duck 6sqmm to 16 sqmm. etc.., complete and as directed by the Engineer-in-charge. | Mtr | 11.8 | 11.8 | 80.0 | False | None | None | False | None | False | 944.0 | 0 |
2905777 | 95424 | None | code85 | Supplying and fixing of class A [ medium duty ] GI pipe of wall thickness not less than 3.25mm on pole / waa/drain crossing with necessary clamping arrangements for UG cable of 1x1 KV class. 40mm etc.., complete and as directed by the Engineer-in-charge. | Mtr | 335.0 | 335.0 | 10.0 | False | None | None | False | None | False | 3350.0 | 0 |