createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709811903858
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3270.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose22-03-2024 16:00:00
tenderQueryClose14-03-2024 16:00:00
technicalBidOpen25-03-2024 16:00:00
publishedDate07-03-2024 18:18:31
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate15-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8002227351
tenderSupplierListNone
tenderSchedule
createdTs1709811903878
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2023-24/BD/WORK_INDENT202
titleConstruction of Post Metric Girls Hostel 2nd Phase at Gangotri Nagara in Tumakuru Town, Tumakuru District
descriptionConstruction of Post Metric Girls Hostel 2nd Phase at Gangotri Nagara in Tumakuru Town, Tumakuru District
categoryWORKS
categoryTextWorks
ecv13048254.00
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount13048254.0
groupOverheadTotalNone
fileNumber332/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17098119040000NoneNoneBuildingsConstruction of Post Metric Girls Hostel 2nd Phase at Gangotri Nagara in Tumakuru Town, Tumakuru District13048254.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296414497986Nonecode01THIRD FLOOR CIVIL WORKS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) consider 70% of finished rate of concrete for column shutteringCum12581.212581.216.52FalseNoneNoneFalseNoneFalse207841.4240
296414597986Nonecode02THIRD FLOOR CIVIL WORKS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) consider 60% of finished rate of concrete for roof beam shutteringCum11841.1311841.1326.51FalseNoneNoneFalseNoneFalse313908.35630
296414697986Nonecode03THIRD FLOOR CIVIL WORKS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) consider 50% of finished rate of concrete for roof slab shutteringCum11101.0611101.0626.54FalseNoneNoneFalseNoneFalse294622.13240
296414797986Nonecode04THIRD FLOOR CIVIL WORKS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) consider 60% of finished rate of concrete for linte lshutteringCum11841.1311841.134.4FalseNoneNoneFalseNoneFalse52100.9720
296414897986Nonecode05THIRD FLOOR CIVIL WORKS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) consider 45% of finished rate of concrete for chejja shutteringCum10731.0210731.022.02FalseNoneNoneFalseNoneFalse21676.66040
296414997986Nonecode06THIRD FLOOR CIVIL WORKS Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) consider 45% of finished rate of concrete for staircase shutteringCum10731.0210731.023.71FalseNoneNoneFalseNoneFalse39812.08420
296415097986Nonecode07Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne96747.7596747.7514.39FalseNoneNoneFalseNoneFalse1392200.12250
296415197986Nonecode08Provision of an Reinforced cement concrete crash barrier at the edges of the road, approaches to bridge structures and medians, constructed with M-25 grade concrete with TMT reinforcement conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at expansion joints filled with pre-moulded asphalt filler board, keyed to the structure on which it is built and installed as per design given in the enclosure to MOST circular No. RW/NH - 33022/1/94-DO III dated 24 June 1994 as per dimensions in the approved drawing and at ocations directed by the Engineer, all as specified. (Area = 0.243 m2/m, single face)Mtr2597.72597.718.0FalseNoneNoneFalseNoneFalse46758.60
296415297986Nonecode09Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1416.771416.77338.13FalseNoneNoneFalseNoneFalse479052.44010
296415397986Nonecode10Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1193.981193.98100.68FalseNoneNoneFalseNoneFalse120209.90640
296415497986Nonecode11Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum106868.42106868.420.79FalseNoneNoneFalseNoneFalse84426.05180
296415597986Nonecode12Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercialSqm3592.743592.7415.84FalseNoneNoneFalseNoneFalse56909.00160
296415697986Nonecode13Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Mtr343.92343.9245.6FalseNoneNoneFalseNoneFalse15682.7520
296415797986Nonecode14Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges -do- with both side prelamSqm2558.832558.8312.6FalseNoneNoneFalseNoneFalse32241.2580
296415897986Nonecode15Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specificationsNos1098.81098.815.0FalseNoneNoneFalseNoneFalse16482.00
296415997986Nonecode16Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm7282.827282.8235.07FalseNoneNoneFalseNoneFalse255408.49740
296416097986Nonecode17Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6185.16185.16.36FalseNoneNoneFalseNoneFalse39337.2360
296416197986Nonecode18Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.32349.32333.27FalseNoneNoneFalseNoneFalse116417.87640
296416297986Nonecode19Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm401.24401.24621.01FalseNoneNoneFalseNoneFalse249174.05240
296416397986Nonecode20Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm108.15108.15954.1359FalseNoneNoneFalseNoneFalse103189.7975850
296416497986Nonecode21Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm170.88170.88954.27FalseNoneNoneFalseNoneFalse163065.65760
296416597986Nonecode22Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm463.96463.96275.1FalseNoneNoneFalseNoneFalse127635.3960
296416697986Nonecode23Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm395.83395.83235.68FalseNoneNoneFalseNoneFalse93289.21440
296416797986Nonecode24Finishing with Epoxy paint (two coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Enginer-in-charge.Sqm190.34190.3447.12FalseNoneNoneFalseNoneFalse8968.82080
296416897986Nonecode25Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm149.25149.2528.44FalseNoneNoneFalseNoneFalse4244.670
296416997986Nonecode26Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm192.51192.51137.55FalseNoneNoneFalseNoneFalse26479.75050
296417097986Nonecode27Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm306.06306.06137.55FalseNoneNoneFalseNoneFalse42098.5530
296417197986Nonecode28Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Sqm1270.761270.76125.84FalseNoneNoneFalseNoneFalse159912.43840
296417297986Nonecode29Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3084.443084.4472.79FalseNoneNoneFalseNoneFalse224516.38760
296417397986Nonecode30Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Sqm961.45961.4545.8FalseNoneNoneFalseNoneFalse44034.410
296417497986Nonecode31Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1567.091567.09235.68FalseNoneNoneFalseNoneFalse369331.77120
296417597986Nonecode32Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GFSqm1521.451521.4554.0FalseNoneNoneFalseNoneFalse82158.30
296417697986Nonecode33Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg181.69181.69870.03FalseNoneNoneFalseNoneFalse158075.75070
296417797986Nonecode34Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg611.05611.05135.0FalseNoneNoneFalseNoneFalse82491.750
296417897986Nonecode35Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm883.59883.5945.8FalseNoneNoneFalseNoneFalse40468.4220
296417997986Nonecode36Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m²Sqm950.64950.6436.0FalseNoneNoneFalseNoneFalse34223.040
296418097986Nonecode37Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/m²)Mtr697.57697.5730.0FalseNoneNoneFalseNoneFalse20927.10
296418197986Nonecode38Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg114.64114.64725.57FalseNoneNoneFalseNoneFalse83179.34480
296418297986Nonecode39Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2117.852117.854.03FalseNoneNoneFalseNoneFalse8534.93550
296418397986Nonecode40Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2139.032139.0313.74FalseNoneNoneFalseNoneFalse29390.27220
296418497986Nonecode41Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2160.212160.2113.74FalseNoneNoneFalseNoneFalse29681.28540
296418597986Nonecode42Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Cum2181.392181.3913.74FalseNoneNoneFalseNoneFalse29972.29860
296418697986Nonecode43Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6724.26724.28.84FalseNoneNoneFalseNoneFalse59441.9280
296418797986Nonecode44Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6791.446791.446.98FalseNoneNoneFalseNoneFalse47404.25120
296418897986Nonecode45Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6858.686858.686.98FalseNoneNoneFalseNoneFalse47873.58640
296418997986Nonecode46Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum6925.936925.936.98FalseNoneNoneFalseNoneFalse48342.99140
296419097986Nonecode47Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm5646.515646.512.88FalseNoneNoneFalseNoneFalse16261.94880
296419197986Nonecode48COMPOUND WALL : Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.Cum99.7599.7531.2FalseNoneNoneFalseNoneFalse3112.20
296419297986Nonecode49Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum107.1107.12.67FalseNoneNoneFalseNoneFalse285.9570
296419397986Nonecode50In ordinary/soft rock without blasting, Depth exceeding 1.5 m, but not exceeding 3 m consider 25% of total excavation qtyCum381.15381.152.67FalseNoneNoneFalseNoneFalse1017.67050
296419497986Nonecode51Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m consider 90% of total excavation qtyCum581.7581.748.14FalseNoneNoneFalseNoneFalse28003.0380
296419597986Nonecode52Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.32.67FalseNoneNoneFalseNoneFalse745.7310
296419697986Nonecode53Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm123.9123.962.4FalseNoneNoneFalseNoneFalse7731.360
296419797986Nonecode54Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.754.16FalseNoneNoneFalseNoneFalse26955.4320
296419897986Nonecode55Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregatesCum6288.456288.458.91FalseNoneNoneFalseNoneFalse56030.08950
296419997986Nonecode56Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates consider 8% of finished rate of concrete for foundation upto plitnth shutteringCum7185.027185.0217.75FalseNoneNoneFalseNoneFalse127534.1050
296420097986Nonecode57Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates consider 50% of finished rate of concrete for plitnth shutteringCum9979.29979.217.16FalseNoneNoneFalseNoneFalse171243.0720
296420197986Nonecode58Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)consider 70% of finished rate of concrete for column shutteringCum12214.7612214.769.14FalseNoneNoneFalseNoneFalse111642.90640
296420297986Nonecode59Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Tonne93929.8593929.854.9FalseNoneNoneFalseNoneFalse460256.2650
296420397986Nonecode60Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per spe specifications.Sqm978.6978.6342.7FalseNoneNoneFalseNoneFalse335366.220
296420497986Nonecode61Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1375.51375.5163.8FalseNoneNoneFalseNoneFalse225306.90
296420597986Nonecode62Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm389.55389.55445.9FalseNoneNoneFalseNoneFalse173700.3450
296420697986Nonecode63Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. consider 75% of total qty for Premium acrelicSqm186.9186.9334.43FalseNoneNoneFalseNoneFalse62504.9670
296420797986Nonecode64Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. consider 25% of total qty for texture paintSqm297.15297.15111.48FalseNoneNoneFalseNoneFalse33126.2820
296420897986Nonecode65Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm5482.055482.0512.0FalseNoneNoneFalseNoneFalse65784.60
296420997986Nonecode66Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3.5 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/mm2 with tape (0.52 mm thick) and weight 43.478 g/m (cost of M.S. angle, C.C. blocks shall be paid separately)Mtr331.8331.8104.0FalseNoneNoneFalseNoneFalse34507.20
296421097986Nonecode67Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.Kg118.65118.65329.97FalseNoneNoneFalseNoneFalse39150.94050
296421197986Nonecode68CONCRETE ROAD : Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.Sqm1178.11178.11.2FalseNoneNoneFalseNoneFalse1413.720
296421297986Nonecode69Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.136.0FalseNoneNoneFalseNoneFalse3855.60
296421397986Nonecode70Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of workCum89.2589.2536.0FalseNoneNoneFalseNoneFalse3213.00
296421497986Nonecode71Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction.Cum110.25110.2518.0FalseNoneNoneFalseNoneFalse1984.50
296421597986Nonecode72Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ m3, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.Cum5166.05166.018.0FalseNoneNoneFalseNoneFalse92988.00
296421697986Nonecode73Construction of M40 Grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base in recommended proportions, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a slip form paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures, curing compound, steel channels, finishing to lines and grades as per drawingCum8616.38616.318.0FalseNoneNoneFalseNoneFalse155093.40
296421797986Nonecode74Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne82961.5582961.550.54FalseNoneNoneFalseNoneFalse44799.2370
296421897986Nonecode75Crack Groove Cutting: Groove shall be cut using hand held electrically operated concrete cutting machine of size of 50 mm wide and 75 mm deep on each side of the crack to form as "V" groove all along the crack to fill the polyester resin/ Epoxy putty (horizontal and vertical cracks). After the groove cutting, the concrete shall be removed from the groove using the pneumatic concrete chipping machine to form "V" groove. The item includes the cost of hire charges for all machineries, tools and barges and all labour charges etc., complete.Mtr787.5787.552.0FalseNoneNoneFalseNoneFalse40950.00
296421997986Nonecode76Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.Mtr2322.62322.610.0FalseNoneNoneFalseNoneFalse23226.00
296422097986Nonecode77Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164:2015 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control Over 10 cm in widthSqm213.15213.158.93FalseNoneNoneFalseNoneFalse1903.42950
296422197986Nonecode78DRAIN WORKS : Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m consider hard soil 10% of total excavation qtyCum107.1107.11.32FalseNoneNoneFalseNoneFalse141.3720
296422297986Nonecode79In ordinary/soft rock without blasting, Depth exceeding 1.5 m, but not exceeding 3 m consider 10% of total excavation qtyCum381.15381.151.32FalseNoneNoneFalseNoneFalse503.1180
296422397986Nonecode80Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work In Hard Rock ( requiring blasting) Depth upto 1.50m consider 80% of total excavation qtyCum581.7581.710.56FalseNoneNoneFalseNoneFalse6142.7520
296422497986Nonecode81Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.30.12FalseNoneNoneFalseNoneFalse33.5160
296422597986Nonecode82Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm123.9123.96.0FalseNoneNoneFalseNoneFalse743.40
296422697986Nonecode83Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregatesCum6288.456288.452.4FalseNoneNoneFalseNoneFalse15092.280
296422797986Nonecode84Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates consider 35% of finished rate of concrete for drain shutteringCum8981.288981.289.6FalseNoneNoneFalseNoneFalse86220.2880
296422897986Nonecode85Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specificationTonne94510.594510.50.66FalseNoneNoneFalseNoneFalse62376.930
296422997986Nonecode86INTERNAL ELECTRICAL - Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends, junction boxes,adhesive paste etc.,and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(KPWD SR 23-24) /I.No.1.1/Pg.No.2) 32 mm dia 2.5mm thickMtr106.0106.060.0FalseNoneNoneFalseNoneFalse6360.00
296423097986Nonecode87Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary.(KPWD SR 23-24) /I.No.1.2/Pg.No.2). 25 mm dia 2mm thickMtr78.078.0120.0FalseNoneNoneFalseNoneFalse9360.00
296423197986Nonecode88Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary.(KPWD SR 23-24) /I.No.1.2/Pg.No.2). 20 mm dia 2mm thickMtr66.066.0140.0FalseNoneNoneFalseNoneFalse9240.00
296423297986Nonecode89Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick conforming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWG GI fish wire wherever necessary.(KPWD SR 23-24) /I.No.1.2/Pg.No.2). 32 mm dia 2.5mm thickMtr103.0103.080.0FalseNoneNoneFalseNoneFalse8240.00
296423397986Nonecode90Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick with suitable size bends,metal junction boxes,adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.(KPWD SR 23-24/I.No.1.3.1,2 /Pg.No.2) 25 mm dia 2mm thickMtr79.079.080.0FalseNoneNoneFalseNoneFalse6320.00
296423497986Nonecode91Supplying heavy gauge PVC conduit pipe……mm dia ......mm thick with suitable size bends,metal junction boxes,adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.(KPWD SR 23-24/I.No.1.3.1,2 /Pg.No.2) 20 mm dia 2mm thickMtr68.068.085.0FalseNoneNoneFalseNoneFalse5780.00
296423597986Nonecode92Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 23-24/I.No.3.4.1,2,3,4,5 /Pg.No.9). 1-3 WayEach138.0138.020.0FalseNoneNoneFalseNoneFalse2760.00
296423697986Nonecode93Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 23-24/I.No.3.4.1,2,3,4,5 /Pg.No.9). 4-5 WayEach177.0177.010.0FalseNoneNoneFalseNoneFalse1770.00
296423797986Nonecode94Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 23-24/I.No.3.4.1,2,3,4,5 /Pg.No.9). 6 WayEach220.0220.010.0FalseNoneNoneFalseNoneFalse2200.00
296423897986Nonecode95Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 23-24/I.No.3.4.1,2,3,4,5 /Pg.No.9). 8 WayEach261.0261.015.0FalseNoneNoneFalseNoneFalse3915.00
296423997986Nonecode96Supplying and flush mounting powder coated / galvanised metal box suitable for mounting modular witch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall.(KPWD SR 23-24/I.No.3.4.1,2,3,4,5 /Pg.No.9). 12 WayEach319.0319.020.0FalseNoneNoneFalseNoneFalse6380.00
296424097986Nonecode97Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 23-24/I.No.3.5.1,2,3,4,5 /Pg.No.9). 1-3 WayEach137.0137.020.0FalseNoneNoneFalseNoneFalse2740.00
296424197986Nonecode98Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 23-24/I.No.3.5.1,2,3,4,5 /Pg.No.9). 4 WayEach175.0175.020.0FalseNoneNoneFalseNoneFalse3500.00
296424297986Nonecode99Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 23-24/I.No.3.5.1,2,3,4,5 /Pg.No.9). 6 WayEach234.0234.025.0FalseNoneNoneFalseNoneFalse5850.00
296424397986Nonecode100Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 23-24/I.No.3.5.1,2,3,4,5 /Pg.No.9). 8 WayEach284.0284.010.0FalseNoneNoneFalseNoneFalse2840.00
296424497986Nonecode101Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(KPWD 23-24/I.No.3.5.1,2,3,4,5 /Pg.No.9). 12 WayEach344.0344.06.0FalseNoneNoneFalseNoneFalse2064.00
296424597986Nonecode102Supplying 4 mm thick plastic sheet with necessary nitches for fixing switches regulators etc, and fixing on existing wooden / metal box using N.F screws.(KPWD SR 23-24/I.No.3.8/Pg.No.10).Sq CM0.410.414000.0FalseNoneNoneFalseNoneFalse1640.00
296424697986Nonecode103Point wiring using Copper wire without switch Short point upto 3 Mtr from the tapping point to outlet via switch box.Each269.0269.02.0FalseNoneNoneFalseNoneFalse538.00
296424797986Nonecode104Medium point above 3 Mtr upto 6 mtr from tapping point to outlet via switch box.Each379.0379.02.0FalseNoneNoneFalseNoneFalse758.00
296424897986Nonecode105Long point above 6 Mtr upto 10 Mtr. tapping point from outlet via switch box.Each555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
296424997986Nonecode106Two out let in a row, above 3 meter upto 6 meter from tapping point to outlet via switchEach677.0677.02.0FalseNoneNoneFalseNoneFalse1354.00
296425097986Nonecode107Three out let in a row, above 6 meter upto 10 meter from tapping point to outlet via switchEach989.0989.02.0FalseNoneNoneFalseNoneFalse1978.00
296425197986Nonecode108Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR23-24/I.No.2.3.2,3,4,5,6,7 /Pg.No.5&6). 1.5 sqmmMtr26.026.0400.0FalseNoneNoneFalseNoneFalse10400.00
296425297986Nonecode109Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR23-24/I.No.2.3.2,3,4,5,6,7 /Pg.No.5&6). 2.5 sqmmMtr42.042.0300.0FalseNoneNoneFalseNoneFalse12600.00
296425397986Nonecode110Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR23-24/I.No.2.3.2,3,4,5,6,7 /Pg.No.5&6). 4 sqmmMtr63.063.0250.0FalseNoneNoneFalseNoneFalse15750.00
296425497986Nonecode111Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR23-24/I.No.2.3.2,3,4,5,6,7 /Pg.No.5&6). 6 sqmmMtr92.092.010.0FalseNoneNoneFalseNoneFalse920.00
296425597986Nonecode112Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR23-24/I.No.2.3.2,3,4,5,6,7 /Pg.No.5&6). 10 sqmmMtr167.0167.0100.0FalseNoneNoneFalseNoneFalse16700.00
296425697986Nonecode113Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multi-strand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & cofirming to latest amendments.(KPWD SR23-24/I.No.2.3.2,3,4,5,6,7 /Pg.No.5&6). 16 sqmmMtr318.0318.056.64FalseNoneNoneFalseNoneFalse18011.520
296425797986Nonecode114Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). 6 Amps One Way switchEach102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
296425897986Nonecode115Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). 6 Amps Two Way switchEach166.0166.06.0FalseNoneNoneFalseNoneFalse996.00
296425997986Nonecode116Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). 6 Amps 3 Way socketEach171.0171.012.0FalseNoneNoneFalseNoneFalse2052.00
296426097986Nonecode117Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). Stepped Fan RegulatorEach357.0357.020.0FalseNoneNoneFalseNoneFalse7140.00
296426197986Nonecode118Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). 16 Amps One Way switchEach180.0180.06.0FalseNoneNoneFalseNoneFalse1080.00
296426297986Nonecode119Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). 6/16 Amps universel socketEach236.0236.02.0FalseNoneNoneFalseNoneFalse472.00
296426397986Nonecode120Modular Switches, Sockets, Fan Regulators, TV/Telephone sockets with Networking&Telecommunications Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. .(KPWD SR 23-24/I.No.3.6.1, 2,3,4,8,11,12 /Pg.No.9). Telephone Socket - RJ 11/TV SocketEach156.0156.02.0FalseNoneNoneFalseNoneFalse312.00
296426497986Nonecode121Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete.(KPWD SR 23-24/I.No.5.19.9, 5.19.10,5.19.11,5.19.8 /Pg.No.18). 4 Way TPN Distribution BoardEach4038.04038.01.0FalseNoneNoneFalseNoneFalse4038.00
296426597986Nonecode122Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete.(KPWD SR 23-24/I.No.5.19.9, 5.19.10,5.19.11,5.19.8 /Pg.No.18). 6 Way TPN Distribution BoardEach4940.04940.01.0FalseNoneNoneFalseNoneFalse4940.00
296426697986Nonecode123Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete.(KPWD SR 23-24/I.No.5.19.9, 5.19.10,5.19.11,5.19.8 /Pg.No.18). 8 Way TPN Distribution BoardEach6091.06091.01.0FalseNoneNoneFalseNoneFalse6091.00
296426797986Nonecode124Supplying and Fixing regular MCB distribution board on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing suitable type capacity MCB's single phase / Three phase double door with powder coated painting, made out of 14 SWG MS enclosure, complete.(KPWD SR 23-24/I.No.5.19.9, 5.19.10,5.19.11,5.19.8 /Pg.No.18). 12Way SP & NEach2329.02329.01.0FalseNoneNoneFalseNoneFalse2329.00
296426897986Nonecode125Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898.(KPWD SR 23-24 /I.No.5.18.1, 5.18.8,5.18.9, 5.18.6 /Pg.No.17). 6-32Amps SPEach415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
296426997986Nonecode126Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898.(KPWD SR 23-24 /I.No.5.18.1, 5.18.8,5.18.9, 5.18.6 /Pg.No.17). 40 Amps TPNEach3044.03044.01.0FalseNoneNoneFalseNoneFalse3044.00
296427097986Nonecode127Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898.(KPWD SR 23-24 /I.No.5.18.1, 5.18.8,5.18.9, 5.18.6 /Pg.No.17). 50-63AmpsTPNEach3088.03088.01.0FalseNoneNoneFalseNoneFalse3088.00
296427197986Nonecode128Supplying and Fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10 kA and wiring complete as required confirming to IEC 60898.(KPWD SR 23-24 /I.No.5.18.1, 5.18.8,5.18.9, 5.18.6 /Pg.No.17). 40 Amps DPEach1060.01060.01.0FalseNoneNoneFalseNoneFalse1060.00
296427297986Nonecode129Supplying , fixing and wiring Residual Current Circuit Breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood / panel board.(KPWD SR 23-24 /I.No.5.20.9, 5.20.10 /Pg.No.18). 63 Amps 4 Pole, 300mAEach5545.05545.01.0FalseNoneNoneFalseNoneFalse5545.00
296427397986Nonecode130TELEPHONE WORKS & DATA WORKS Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable of approved make.(KPWD SR 23-24 /I.No.8.2.2, 8.2.5, 8.2.5, 8.1 /Pg.No.36). 2 PairMtr21.021.080.0FalseNoneNoneFalseNoneFalse1680.00
296427497986Nonecode131TELEPHONE WORKS & DATA WORKS Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable of approved make.(KPWD SR 23-24 /I.No.8.2.2, 8.2.5, 8.2.5, 8.1 /Pg.No.36). 5 PairMtr46.046.040.0FalseNoneNoneFalseNoneFalse1840.00
296427597986Nonecode132Supplying and Drawing UTP-CAT - 6E LAN CableMtr38.038.030.0FalseNoneNoneFalseNoneFalse1140.00
296427697986Nonecode133Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. and M.S.flat .. with bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . a) 40 x 40 x 6 mm .Mtr305.0305.01.0FalseNoneNoneFalseNoneFalse305.00
296427797986Nonecode134Supplying and fixing angle iron frame work fabricated out of M.S angle iron .. and M.S.flat .. with bolts , washers etc., and painted with 2 coats of red oxide and then two coats of approved paint . b) 50 x 50 x6 mm .Mtr395.0395.01.0FalseNoneNoneFalseNoneFalse395.00
296427897986Nonecode135Fabricating supplying and mounting MS box made out …. SWG suitable for floor / wall mounting , fully weather poof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper poof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tank treatment with powder coated paint and finally finished with approved colour etc., complete . b) 14 SWGSq CM0.50.53000.0FalseNoneNoneFalseNoneFalse1500.00
296427997986Nonecode136Supplying, fixing and wiring of earth electrode for grounding of lifts, Transformers DG Sets etc, using 40mm dia 2.9 mm thick 2.5 meter long GI pipe with GI nnel with mesh & suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400 X 400 X 400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using bolts and nuts.(KPWD SR 23-24 /I.No.12.57/Pg.No.54).No4256.04256.01.0FalseNoneNoneFalseNoneFalse4256.00
296428097986Nonecode137Supply and Installation of Conventional type, 5 segment 50mm dia hollow copper spike (air termination rod) for lightning protection with copper down rod and necessary fixing hardware as per IS 2309, 1969 ( MR)No5200.05200.01.0FalseNoneNoneFalseNoneFalse5200.00
296428197986Nonecode138Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required.(KPWD SR 23-24 /I.No.12.58.1,2 /Pg.No.54). a) 25 X 3 mm GI stripMtr82.082.020.0FalseNoneNoneFalseNoneFalse1640.00
296428297986Nonecode139Supplying and running of GI/Copper stripes for grounding connections, using necessary fixing materials as required.(KPWD SR 23-24 /I.No.12.58.1,2 /Pg.No.54). a) 25 X 6 mm GI StripMtr128.0128.010.0FalseNoneNoneFalseNoneFalse1280.00
296428397986Nonecode140Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 23-24 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). a) 8 SWG Copper wireMtr105.0105.025.0FalseNoneNoneFalseNoneFalse2625.00
296428497986Nonecode141Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 23-24 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). b) 10 SWG Copper wireMtr68.068.025.0FalseNoneNoneFalseNoneFalse1700.00
296428597986Nonecode142Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 23-24 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). c) 8 SWG GI wireMtr19.019.010.0FalseNoneNoneFalseNoneFalse190.00
296428697986Nonecode143Supplying and running GI/Copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, Nails, gattas/Spacers etc,.(KPWD SR 23-24 /I.No.6.18.6, 6.18.5, 6.18.3, 6.18.2 /Pg.No.43-44). d) 10 SWG GI wireMtr15.015.010.0FalseNoneNoneFalseNoneFalse150.00
296428797986Nonecode144Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a. 450 X 50 mmMtr913.0913.04.0FalseNoneNoneFalseNoneFalse3652.00
296428897986Nonecode145Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. 1x2 ' - 9/10wEach551.0551.025.0FalseNoneNoneFalseNoneFalse13775.00
296428997986Nonecode146Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. 1x4' - 20/22 wEach690.0690.06.0FalseNoneNoneFalseNoneFalse4140.00
296429097986Nonecode147Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting. 2x4' - 20/22 wEach1269.01269.02.0FalseNoneNoneFalseNoneFalse2538.00
296429197986Nonecode148Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 23-24 /I.No.13.7.1, 13.7.2 /Pg.No.56). a) On Wall / Ceiling / Rafter / GridersEach122.0122.08.0FalseNoneNoneFalseNoneFalse976.00
296429297986Nonecode149Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 23-24 /I.No.13.7.1, 13.7.2 /Pg.No.56). b) Using necessary length of G.I. ChainEach263.0263.012.0FalseNoneNoneFalseNoneFalse3156.00
296429397986Nonecode150Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 10-12 WEach885.0885.04.0FalseNoneNoneFalseNoneFalse3540.00
296429497986Nonecode151Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 15-18 WEach1324.01324.06.0FalseNoneNoneFalseNoneFalse7944.00
296429597986Nonecode152Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps.(KPWD SR 23-24 /I.No.13.7.1, /Pg.No.56). a) On Wall / Ceiling / Rafter / GridersEach122.0122.010.0FalseNoneNoneFalseNoneFalse1220.00
296429697986Nonecode153Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 5-6 W (Mirror Light)Each571.0571.04.0FalseNoneNoneFalseNoneFalse2284.00
296429797986Nonecode154Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED Square or round down light 10-12 W (Bulk head Light)Each885.0885.06.0FalseNoneNoneFalseNoneFalse5310.00
296429897986Nonecode155Fixing all types and capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafter / griders using 23/0.0076" twin twisted PVC insulated wires, required no.s of round blocks and clamps. a) On Wall / Ceiling / Rafter / GridersEach122.0122.02.0FalseNoneNoneFalseNoneFalse244.00
296429997986Nonecode156Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system 48" Sweep (1200mm) Regular modelEach2984.02984.07.0FalseNoneNoneFalseNoneFalse20888.00
296430097986Nonecode157Supplying wall mounting Fan suitable to operate at single-phase 230V AC supply .Each3212.03212.07.0FalseNoneNoneFalseNoneFalse22484.00
296430197986Nonecode158Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Each315.0315.08.0FalseNoneNoneFalseNoneFalse2520.00
296430297986Nonecode159a)Supplying exhaust fan of 1440 RPM of 300mm (12" ) size with bracket blades complete for light duty suitable to operate on 230v 50Hz , AC Supply…Each1492.01492.016.0FalseNoneNoneFalseNoneFalse23872.00
296430397986Nonecode160Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each707.0707.016.0FalseNoneNoneFalseNoneFalse11312.00
296430497986Nonecode161Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 100 LitresEach31778.031778.02.0FalseNoneNoneFalseNoneFalse63556.00
296430597986Nonecode162Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 200 LitresEach46914.046914.01.0FalseNoneNoneFalseNoneFalse46914.00
296430697986Nonecode163Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 300 LitresEach69986.069986.01.0FalseNoneNoneFalseNoneFalse69986.00
296430797986Nonecode164Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. 5 kVA ON LINE UPSEach68383.068383.01.0FalseNoneNoneFalseNoneFalse68383.00
296430897986Nonecode165Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 / 80 AH capacityEach10172.010172.02.0FalseNoneNoneFalseNoneFalse20344.00
296430997986Nonecode166INTERNAL WATER SUPPLY & SANITORY WORK Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mMtr508.2508.210.0FalseNoneNoneFalseNoneFalse5082.00
296431097986Nonecode167Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.310.0FalseNoneNoneFalseNoneFalse2793.00
296431197986Nonecode168Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant IS/ ISO/DIN/BIS codes and also testing of joints complete as per direction of Engineer-In- Charge.etc. complete PN - 16 Pipe, SDR 7.4 -16 mm ODMtr199.5199.540.0FalseNoneNoneFalseNoneFalse7980.00
296431297986Nonecode169Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant IS/ ISO/DIN/BIS codes and also testing of joints complete as per direction of Engineer-In- Charge.etc. complete PN - 16 Pipe, SDR 7.4 -20 mm ODMtr215.25215.2545.0FalseNoneNoneFalseNoneFalse9686.250
296431397986Nonecode170Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant IS/ ISO/DIN/BIS codes and also testing of joints complete as per direction of Engineer-In- Charge.etc. complete PN - 16 Pipe, SDR 7.4-25 mm ODMtr266.7266.735.0FalseNoneNoneFalseNoneFalse9334.50
296431497986Nonecode171Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801: 2008 OR WRAS, NSF certificates which is UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes Lot wise test report as per the relevant IS/ ISO/DIN/BIS codes and also testing of joints complete as per direction of Engineer-In- Charge.etc. complete PN - 16 Pipe,SDR 7.4- 32 mm ODMtr362.25362.2530.0FalseNoneNoneFalseNoneFalse10867.50
296431597986Nonecode172Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :Each5079.95079.98.0FalseNoneNoneFalseNoneFalse40639.20
296431697986Nonecode173600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Unit520.8520.88.0FalseNoneNoneFalseNoneFalse4166.40
296431797986Nonecode174Providing and fixing brass bib cock of approved quality : 15 mm nominal boreNos300.3300.310.0FalseNoneNoneFalseNoneFalse3003.00
296431897986Nonecode175Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach3009.33009.38.0FalseNoneNoneFalseNoneFalse24074.40
296431997986Nonecode176Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mmEach5662.655662.651.0FalseNoneNoneFalseNoneFalse5662.650
296432097986Nonecode177Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal boreEach576.45576.454.0FalseNoneNoneFalseNoneFalse2305.80
296432197986Nonecode178Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal boreEach627.9627.92.0FalseNoneNoneFalseNoneFalse1255.80
296432297986Nonecode179Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal boreEach737.1737.12.0FalseNoneNoneFalseNoneFalse1474.20
296432397986Nonecode180Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Nos5726.75726.71.0FalseNoneNoneFalseNoneFalse5726.70
296432497986Nonecode181Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. PN - 16 Pipe,SDR 7.4-40 mm ODMtr527.1527.145.0FalseNoneNoneFalseNoneFalse23719.50
296432597986Nonecode182Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. PN - 16 Pipe,SDR 7.4- 32 mm ODMtr362.25362.2540.0FalseNoneNoneFalseNoneFalse14490.00
296432697986Nonecode183Providing and fixing 3 layer PP-R (Poly Propylene Random Copolymer) pipes confirming to IS.15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply, including all PP-R plain and brass threaded polypropylene random fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per direction of Engineer-In- Charge. PN - 16 Pipe,SDR 7.4-63 mm ODMtr991.2991.235.0FalseNoneNoneFalseNoneFalse34692.00
296432797986Nonecode184Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3Mtr613.2613.276.79FalseNoneNoneFalseNoneFalse47087.6280
296432897986Nonecode185Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3Mtr431.55431.5560.0FalseNoneNoneFalseNoneFalse25893.00
296432997986Nonecode186Providing and placing on terrace polyethylene water storage tanks as per IS : 12701 : 1996 with manhole lid and suitable locking arrangements, aking holes of suitable diameter for inlet, outlet and overflow pipes, includng cost of all materilas, labour, transporation charges HOM of Equipmnts and testing complete as per specificatiosnsLtr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
296433097986Nonecode187NON SR ITEM Supplying and fixing of liquid soap dispenser with glass bottle fixed on wooden cleats with CP brass screws & washers including driling hole in walls with drill gun and making good the walls.Each1184.91184.98.0FalseNoneNoneFalseNoneFalse9479.20
296433197986Nonecode188Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.Mtr25.4225.42950.0FalseNoneNoneFalseNoneFalse24149.00
296433297986Nonecode189Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, covering the top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc. The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor. The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Alternate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration. 3 Nos. bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually. Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration.Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge.Each22960.022960.01.0FalseNoneNoneFalseNoneFalse22960.00
296433397986Nonecode190NON SR ITEMS : Providing and fixing Alluminium fixtures like 1 no of Aldrops of size 300 x 16 mm, 2 no's of Tower bolts of size 200 x 12 mm, 100 mm length ss Hinges, 2nos of Handles of size 200 mm, 1 no of Door Stopper & 1 no of Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works.Each807.7807.715.0FalseNoneNoneFalseNoneFalse12115.50
296433497986Nonecode191Supplying and fixing of Robe hook Fixed on the toilet Door as directed by the Engineer in charge.Each525.62525.625.0FalseNoneNoneFalseNoneFalse2628.10
296433597986Nonecode192Supplying, fixing, testing and commissioning of 15mm dia CP Long body Bib Cock (wall mounted model) for wash area with CP wall flange etc.Nos738.0738.05.0FalseNoneNoneFalseNoneFalse3690.00
296433697986Nonecode193Providing & fixing of CP waste coupling 32mm Size full thread for Truf.Each369.0369.05.0FalseNoneNoneFalseNoneFalse1845.00
296433797986Nonecode194Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge.Each258.3258.310.0FalseNoneNoneFalseNoneFalse2583.00
296433897986Nonecode195Supplying , installing, testing and commissioning of brass body nickel plated automatic air release valves with brass splindle, NBR and joinfraniteelastomer,staniless steel spring polypropylenic float at the top most points of watersupply distribution ringmain.Each1125.041125.044.0FalseNoneNoneFalseNoneFalse4500.160
296433997986Nonecode196Supplying and fixing in position solid block masonry pedestals of approaximate size 400x230x230mm with brackets and G.I clamps for laying pipes on terrace. etc,. complete as directed by the Engineer in charge.Each410.0410.010.0FalseNoneNoneFalseNoneFalse4100.00
296434097986Nonecode197Providing, fixing, testing and commissioning of PVC gullytrap of 150 x 150 mm size with 100 mm dia outlet making excavation pit in all kinds of soil and laying of 100 mm thick 1:4:8 mix cement concrete bed and constructing chamber with internal clear dimension of 300 x 300 mm using table moulded wire cut bricks in brick work 115 mm thick in cement mortar 1:4 up to a height of 300 mm above gully trap or up to 100 mm above paving level, plastering internal and external surface with cement mortar 1:4 to 15m thick finishing to smooth inside surface with necessary benching and channelling providing 150 x 150 mm size cast iron grating, including 40 mm thick precast RCC cover slab, clearing the surplus material, earth etc. complete as per drawing. 150mm x 150mm size 'P/S' trapNos3690.03690.02.0FalseNoneNoneFalseNoneFalse7380.00
296434197986Nonecode198Providing, fixing, testing and commissioning of PVC rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 300 x 300mm PVC GratingNos1972.921972.926.0FalseNoneNoneFalseNoneFalse11837.520
296434297986Nonecode199Providing, fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 300 x 300mm PVC GratingNos1972.921972.926.0FalseNoneNoneFalseNoneFalse11837.520
296434397986Nonecode200Providing & fixing of brass Y' / pot strainer screw type tested to 20 kg / sq.cm.Each4834.724834.722.0FalseNoneNoneFalseNoneFalse9669.440
296434497986Nonecode201Construction of valve chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick & plastering in CM 1:6 15 mm thick with adding water proof compound as per standard specifications for bottom and internal side walls, exposed top surface finished smooth etc., including necessary excavation in all types of soil, back filling including consolidation, disposing of surplus earth to all leads & providing precast RCC cover with frame of SFRC and weight not less than 90 kgs (as per standard make or SFRC / southern concrete company) curing etc. complete as per the drawing. Size 750 x450X 450mm deepNos5740.05740.01.0FalseNoneNoneFalseNoneFalse5740.00
296434597986Nonecode202Construction of valve chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick & plastering in CM 1:6 15 mm thick with adding water proof compound as per standard specifications for bottom and internal side walls, exposed top surface finished smooth etc., including necessary excavation in all types of soil, back filling including consolidation, disposing of surplus earth to all leads & providing precast RCC cover with frame of SFRC and weight not less than 90 kgs (as per standard make or SFRC / southern concrete company) curing etc. complete as per the drawing. Size 600 x 600 x 600mm deepNos4920.04920.01.0FalseNoneNoneFalseNoneFalse4920.00
296434697986Nonecode203CAMERAS & ACCESSORIES: Supply, erection, testing & commissioning 2 Megapixel high-performance CMOS, Analog HD output, up to 1080P resolution, True Day/Night, True WDR, up to 120dB,EXIR technology, up to 20m IR distance , IP66 weatherproof ,Max. 5W, with 4*4 Model Box for Camera and other accessories.Nos4524.764524.766.0FalseNoneNoneFalseNoneFalse27148.560
296434797986Nonecode204Supply, erection, testing & commissioning of 12/24V, 4 out put Camera Power Supply (SMPS, switched-mode power supply) Each Camera have Separate Terminal, including all Accessories.Nos1256.241256.246.0FalseNoneNoneFalseNoneFalse7537.440
296434897986Nonecode205Supply, erection, testing & commissioning of High resolution 16 channel Supply, erection, testing & commissioning of High resolution 16 channel with following configuration. High performance Triple Platform HD TVI DVR, with H.264 Compression (High Profile) Max 1080p HD resolution supported HD TVI, Analog and IP cameras supported; Supports ONVIF Under NVR Mode HDD 1 HDDs upto 4TB supported Audio Input/output 1 In/1 Out Video Outputs 1 x HDMI, 1 x VGA Network Port 1 x Gigabit (10/100/1000) adaptive network port Multi Input modes Analog (16 x 720p HD TVI/ 16 x 960H); Network (2 x 720P/ 960P/ 1080P), 2 TB Sata Surveillance HDD storage capacity.Nos42856.4842856.481.0FalseNoneNoneFalseNoneFalse42856.480
296434997986Nonecode206Supply, Installation, Testing & Commissioning of 24inch LED Monitor with all accessories.Nos14076.1214076.121.0FalseNoneNoneFalseNoneFalse14076.120
296435097986Nonecode207Supply and laying of 3+1 Camera Cable with power and co axial (Pure Copper) in Existing 25mm Dia PVC conduits with all necessary accessories.Mtr34.4434.44210.0FalseNoneNoneFalseNoneFalse7232.40
296435197986Nonecode208Supply and Termination of above cable by using BNC connector and DC pin with all accessories.Mtr185.32185.32102.0FalseNoneNoneFalseNoneFalse18902.640
296435297986Nonecode209Supply and fixing of Krone type tag block with lock & key enclosed in a MS. box of cable terminations.5 PairNos401.8401.88.0FalseNoneNoneFalseNoneFalse3214.40
296435397986Nonecode210Supply and fixing of Krone type tag block with lock & key enclosed in a MS. box of cable terminations.20 PairNos1105.361105.364.0FalseNoneNoneFalseNoneFalse4421.440
296435497986Nonecode211Supply and Installation of EPABX for Intercom system for 1 No. Direct lines, 1No. STD Line, 24Nos. Extension Lines, with other standard specification.Nos25138.7425138.741.0FalseNoneNoneFalseNoneFalse25138.740
296435597986Nonecode212FURNITURE WORKS BACK STORAGE (Length between 5770 to 6250mm) x 600mm depth x 2100mm height:Back Storage: Providing & fabricating storage formed out of 19mm thick ply & finished with 4mm thk approved Veneer and melamine polished. The storage shall consists of shutters & shelves in 19mm thk ply & finished with 1.5mm thk approved laminate on both sides. The shutters for the central top portion to be formed out of 6mm thick plain toughened glass as per the detail drawings. The shutters shall be mounted over spring loaded auto closing hinges of approved make, tower bolt. The exposed edges of the storage shall be lipped using approved edge binding, complete as per detail dwg. & instructions of the Engineer-in-charge.Mode of Measurement : Length & Height of the storage shall be measure for payment.Nos14353.2814353.2818.0FalseNoneNoneFalseNoneFalse258359.040
296435697986Nonecode213STORAGE/TABLE: Providing and fixing storage unit of 0.45m depth / actual measurement as per the drawing made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply backing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specifications & instructions of the Engineer-in-charge.Mode of measurement : Length & height of the storage shall be measured for payment.Sqm7482.57482.545.6FalseNoneNoneFalseNoneFalse341202.00
296435797986Nonecode214CABIN TABLES - TYPE-2:Table Dimension: 1800mm x 750mm x 750mm: Providing and Fabricating Cabin Table with 19mm ply Finished with 4mmthk Approved Veneer Melamine finished. Table top: 19mm thick table top to be formed out of 19mm tk ply and to be finished with 4mm thk approved Veneer and melamine polished. The edge of the table to be provided with approved timber beading to form 30mm thick fascia formed to shape Finished with approved Melamine polish to match the veneer. The top to house cable trough / cable pop up box for cable management with 19mm thk ply openable as per details, complete as per detail dwg. Base: The base of the table shall consist of 19mm commercial ply finished with 4mm thk veneer of approved make & shade. complete as per the drawing & instructions of the Engineer-in-charge.Sqm16703.416703.41.0FalseNoneNoneFalseNoneFalse16703.40
296435897986Nonecode215MEDIUM BACK CHAIR- FABRIC with castors:Supplying & placing in position medium back chair with following specification.Seat: Seat to be formed out of bent ply / PVC backing with deformable pre moulded foam upholstered with approved fabric.Back rest: The medium back rest in fabric over frame. The back rest to have provision of height adjustable backrest for an optimum adjustment of the lumbar support, to be either by turning knob or push- button. upholstered with Mesh fabric.Mechanism: Synchronised knee-tilt with 2 way locking mechanism.Gas lift: synchronised gas lift.Arm rest: Fixed arm rest to be formed out of PU foam / PVC with provision of height swinging adjustment, Width adjustment, height adjustments. Base: Base shall consist of 5 prong formed of Nylon legs finish with soft-dual wheel casters.Castors: Twin wheel high resistant polyamide castors.Nos7030.687030.683.0FalseNoneNoneFalseNoneFalse21092.040
296435997986Nonecode216Study Chair : SEAT / BACK The seat and back are made up of injection moulded high impact strength polypropylene polymer compound with indoor grade UV resistence. M.S POWDER COATED UNDERSTRUCTURE FOR CHAIR: The Powde coated (DFT 50+10 microns) welded tubular frame is made from O 2.22+0.03cm x 0.16+0.0128cm and 3.5+0.03cm x 1.5+0.03cm x 0.16+0.0128cm M.S.E.R.W tube. SHOE The shoes areamade of high impact strength polypropylene polymer compound with indoor grade UV resistance and pressed fitted with tubular frame the product should be knock down and assembled at siteNos2378.02378.0100.0FalseNoneNoneFalseNoneFalse237800.00
296436097986Nonecode217SINGLE COT Diamension : 2100x900mm Providing & placing the single cot made out of MS struture power coated as per the manufactures specification & Architects instruction.Nos6150.06150.01.0FalseNoneNoneFalseNoneFalse6150.00
296436197986Nonecode218PANTRY COUNTER - GRANITE TOPFabricating and fixing low height storage cabinet of height 850mm and depth 600mm formed of 19mm marine grade plywood formwork/carcass for front, sides & back formed out of 12mm thick marine grade ply, internal shelves of 19mm marine ply. Shutter of storage unit to be made of 19mm thk marine ply finished with 1.5mm thk laminate The shutter shall be mounted on 3Nos of approved spring loaded auto closing hinges of approved make. The rear backing of the storage shall be formed of 8mm thick marine plywood. Low height cabinet to be topped with 20mm thick approved Granite counter sandwiched at the edge to form a fascia of 40mm thick affixed to carcass with exposed edge profiled full round and polished to high gloss with 50mm height skirting formed out of 19mm thk marine ply & finished in 1.5mm thick Laminate sheet as per detail dwg. Storage to be complete with hardware installed as directed to consist of the following. Shutter to have auto-closing spring loaded hinge of approved make installed strictly as per manufacturers guidelines. All necessary tools should be strictly used for correct installation of hinges. Each set of shutters to be provided with 1 Nos. chrome finished multi-purpose lock of approved make, 75mm medium sized stainless steel tower bolt, 1 Nos. heavy duty SS ball catch, 100mm C type brushed SS handle. complete as per the instructions of the Engineer-in-charge.Mode of measurement: Length & height of the storage shall be measured for payment.Nos11835.0611835.064.05FalseNoneNoneFalseNoneFalse47931.9930
296436297986Nonecode219Z-TYPE FIXED LOUVERESSupplying, providing and fixing in position Aluminium framework(frame as per SR code 0533/Pg84) with aluminium louvers of louver thickness not less than 2mm thick with fly mesh provision as per the detail drawing provided by the vendor and executed as per instructions of the Engineer-in-charge.At all levels, leads and lifts.Sqm3300.53300.59.0FalseNoneNoneFalseNoneFalse29704.50
296436397986Nonecode220TWO TIER COT: The bed shall be of size: 2100 mm H x 760Dmm D X 1980mm W The height of lower tier from the floor shall be 460mm and the upper tier shall be at a height of 1000mm from the lower tier. The bed frame assembly is a welding of inner frame, slat & cladding. The side frame assembly shall be made up of Sq. Tube 38.1 x 1.2mm thick. Inner slats shall be made up of 19 x 1.0mm thick MS ERW tube of Grade IS: 7138. Cladding shall be made up of 1.2mm thick CRCA sheet of GRADE IS: 513. The Head Board & Tail Board shall be made up of SQ.PIPE 38.1 X 1.6mm & Sq. 25.4 x 1.0mm thick MS ERW TUBE OF GRADE IS: 7138. And the support bracket shall be made up of 3.2mm thick MS Sheet of Grade IS: 513. The Manufacturer shall be a member of BIFMA for a continuous period of 10 years and shall have latest ISO 9001:2015, ISO 14001: 2015, ISO 45001:2018, EN ISO 50001: 2018. Head / Tail Boards are connected to the bed frame assembly with M8 nut & Bolt. Grouting CON flange of 3.2mm thick MS sheet provided at the bottom of vertical pipe for fixing to the ground with suitable grouting bolt. The ladder assembly shall be made up of SQ. 25.4X 1.0mm thick & SQ.19 X 1.0mm thick MS ERW tube of GRADE IS: 7138. Side support shall be made of dia25.4 x 1.2mm thick &dia19 x 1.0mm thick tube. Mosquito Rod of dia 19 x 0.8mm thick MS ERW tube to be fit in dia 22 x 1.0mm thick MS ERW Tube& both the tubes are of grade IS: 7138. Mosquito rod is fixed with rod holder with the help of screw. Hook is made up of dia 6mm thick. The entire cot shall be EPOXY POLYESTER POWDER COATED with DFT 40 60 micron.Nos31790.5831790.5850.0FalseNoneNoneFalseNoneFalse1589529.00
296436497986Nonecode221Providing and Supplying Stainless steel Dining Table with Bench sets - 1 sets contain one dining table and 2 benches each bench of 4 seater of Size-Table : 2250mm x 800mm x 750mm H -10 seater, Size-Bench (2 Nos) : 2250mm x 300mm x 450mm H, Frame (Table & Bench) : 30mm & 25mm Sq. x 1.2mm thick, stainless steel tube-202 grade, Top (Table & Bench) : 1.2mm thick stainless steel sheet-polished-202 grade, including transportation, loading, unloading, fixing labhour & all other charges etc.., as per the direction of Engineer in-charge. Dining Hall (Total Seating Capacity - 80 Students)Nos27060.027060.028.0FalseNoneNoneFalseNoneFalse757680.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17098119050000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17098119050000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17098119050000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17098119120000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17098119160000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17098119210000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17098119250000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17098119300000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17098119330000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17098119370000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17098119420000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17098119450000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17098119510000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17098119540000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17098119580000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17098119610000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17098119660000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17098119710000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709814936000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone