2965139 | 98022 | None | code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS | Cum | 12101.91 | 12101.91 | 4.75 | False | None | None | False | None | False | 57484.0725 | 0 |
2965140 | 98022 | None | code02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. | Cum | 11390.04 | 11390.04 | 8.21 | False | None | None | False | None | False | 93512.2284 | 0 |
2965141 | 98022 | None | code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. | Cum | 10678.16 | 10678.16 | 39.37 | False | None | None | False | None | False | 420399.1592 | 0 |
2965142 | 98022 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. | Cum | 11390.04 | 11390.04 | 2.14 | False | None | None | False | None | False | 24374.6856 | 0 |
2965143 | 98022 | None | code05 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9377.94 | 9377.94 | 1.87 | False | None | None | False | None | False | 17536.7478 | 0 |
2965144 | 98022 | None | code06 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93062.12 | 93062.12 | 6.71 | False | None | None | False | None | False | 624446.8252 | 0 |
2965145 | 98022 | None | code07 | KSRB 4-2.12 : Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. Specification No . KBS | Mtr | 33.0 | 33.0 | 19.8 | False | None | None | False | None | False | 653.4 | 0 |
2965146 | 98022 | None | code08 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1362.79 | 1362.79 | 223.44 | False | None | None | False | None | False | 304501.7976 | 0 |
2965147 | 98022 | None | code09 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1148.49 | 1148.49 | 10.62 | False | None | None | False | None | False | 12196.9638 | 0 |
2965148 | 98022 | None | code10 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 102797.24 | 102797.24 | 0.44 | False | None | None | False | None | False | 45230.7856 | 0 |
2965149 | 98022 | None | code11 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1056.94 | 1056.94 | 6.0 | False | None | None | False | None | False | 6341.64 | 0 |
2965150 | 98022 | None | code12 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. | Nos | 1094.4 | 1094.4 | 6.0 | False | None | None | False | None | False | 6566.4 | 0 |
2965151 | 98022 | None | code13 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Nos | 1029.9 | 1029.9 | 6.0 | False | None | None | False | None | False | 6179.4 | 0 |
2965152 | 98022 | None | code14 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete | Nos | 246.55 | 246.55 | 12.0 | False | None | None | False | None | False | 2958.6 | 0 |
2965153 | 98022 | None | code15 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Nos | 135.24 | 135.24 | 12.0 | False | None | None | False | None | False | 1622.88 | 0 |
2965154 | 98022 | None | code16 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms | Nos | 57.22 | 57.22 | 6.0 | False | None | None | False | None | False | 343.32 | 0 |
2965155 | 98022 | None | code17 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Nos | 286.08 | 286.08 | 12.0 | False | None | None | False | None | False | 3432.96 | 0 |
2965156 | 98022 | None | code18 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm | Nos | 62.42 | 62.42 | 36.0 | False | None | None | False | None | False | 2247.12 | 0 |
2965157 | 98022 | None | code19 | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. | Mtr | 12.71 | 12.71 | 40.8 | False | None | None | False | None | False | 518.568 | 0 |
2965158 | 98022 | None | code20 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial | Sqm | 3455.88 | 3455.88 | 14.4 | False | None | None | False | None | False | 49764.672 | 0 |
2965159 | 98022 | None | code21 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7005.38 | 7005.38 | 16.2 | False | None | None | False | None | False | 113487.156 | 0 |
2965160 | 98022 | None | code22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 174.77 | 174.77 | 291.6 | False | None | None | False | None | False | 50962.932 | 0 |
2965161 | 98022 | None | code23 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1158.89 | 1158.89 | 6.0 | False | None | None | False | None | False | 6953.34 | 0 |
2965162 | 98022 | None | code24 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) | Sqm | 324.57 | 324.57 | 432.21 | False | None | None | False | None | False | 140282.3997 | 0 |
2965163 | 98022 | None | code25 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 104.03 | 104.03 | 781.32 | False | None | None | False | None | False | 81280.7196 | 0 |
2965164 | 98022 | None | code26 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 363.06 | 363.06 | 142.2677 | False | None | None | False | None | False | 51651.711162 | 0 |
2965165 | 98022 | None | code27 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. | Mtr | 54.1 | 54.1 | 174.72 | False | None | None | False | None | False | 9452.352 | 0 |
2965166 | 98022 | None | code28 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm | Sqm | 1222.35 | 1222.35 | 123.3 | False | None | None | False | None | False | 150715.755 | 0 |
2965167 | 98022 | None | code29 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rub- bing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2565.38 | 2565.38 | 34.86 | False | None | None | False | None | False | 89429.1468 | 0 |
2965168 | 98022 | None | code30 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 1507.39 | 1507.39 | 48.48 | False | None | None | False | None | False | 73078.2672 | 0 |
2965169 | 98022 | None | code31 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 1492.47 | 1492.47 | 58.2 | False | None | None | False | None | False | 86861.754 | 0 |
2965170 | 98022 | None | code32 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 132.12 | 132.12 | 781.32 | False | None | None | False | None | False | 103227.9984 | 0 |
2965171 | 98022 | None | code33 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 162.29 | 162.29 | 141.66 | False | None | None | False | None | False | 22990.0014 | 0 |
2965172 | 98022 | None | code34 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 52.02 | 52.02 | 16.2 | False | None | None | False | None | False | 842.724 | 0 |
2965173 | 98022 | None | code35 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 119.63 | 119.63 | 16.2 | False | None | None | False | None | False | 1938.006 | 0 |
2965174 | 98022 | None | code36 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.14 | 55.14 | 34.56 | False | None | None | False | None | False | 1905.6384 | 0 |
2965175 | 98022 | None | code37 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 704.28 | 704.28 | 34.56 | False | None | None | False | None | False | 24339.9168 | 0 |
2965176 | 98022 | None | code38 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR | Kg | 581.95 | 581.95 | 183.75 | False | None | None | False | None | False | 106933.3125 | 0 |
2965177 | 98022 | None | code39 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FIRST FLOOR | Kg | 587.77 | 587.77 | 123.11 | False | None | None | False | None | False | 72360.3647 | 0 |
2965178 | 98022 | None | code40 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. FIRST FLOOR | Kg | 152.92 | 152.92 | 51.3 | False | None | None | False | None | False | 7844.796 | 0 |
2965179 | 98022 | None | code41 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 151.41 | 151.41 | 51.3 | False | None | None | False | None | False | 7767.333 | 0 |
2965180 | 98022 | None | code42 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. COLUMNS | Cum | 12221.73 | 12221.73 | 1.32 | False | None | None | False | None | False | 16132.6836 | 0 |
2965181 | 98022 | None | code43 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 93983.52 | 93983.52 | 0.3 | False | None | None | False | None | False | 28195.056 | 0 |
2965182 | 98022 | None | code44 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1376.29 | 1376.29 | 169.0 | False | None | None | False | None | False | 232593.01 | 0 |
2965183 | 98022 | None | code45 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 366.66 | 366.66 | 338.0 | False | None | None | False | None | False | 123931.08 | 0 |
2965184 | 98022 | None | code46 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 163.89 | 163.89 | 338.0 | False | None | None | False | None | False | 55394.82 | 0 |
2965185 | 98022 | None | code47 | PVC pipes of 6 Kg/cm2 for 110mm(1.894) | Mtr | 267.9 | 267.9 | 36.0 | False | None | None | False | None | False | 9644.4 | 0 |
2965186 | 98022 | None | code48 | Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa- terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa- terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 858.34 | 858.34 | 629.0 | False | None | None | False | None | False | 539895.86 | 0 |
2965187 | 98022 | None | code49 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 154.44 | 154.44 | 13175.0 | False | None | None | False | None | False | 2034747.0 | 0 |
2965188 | 98022 | None | code50 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required | Sqm | 596.74 | 596.74 | 577.25 | False | None | None | False | None | False | 344468.165 | 0 |
2965189 | 98022 | None | code51 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm) | m | 473.82 | 473.82 | 30.0 | False | None | None | False | None | False | 14214.6 | 0 |
2965190 | 98022 | None | code52 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth) | m | 1128.34 | 1128.34 | 60.0 | False | None | None | False | None | False | 67700.4 | 0 |
2965191 | 98022 | None | code53 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch | Point | 277.07 | 277.07 | 6.0 | False | None | None | False | None | False | 1662.42 | 0 |
2965192 | 98022 | None | code54 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 287.37 | 287.37 | 10.0 | False | None | None | False | None | False | 2873.7 | 0 |
2965193 | 98022 | None | code55 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 571.65 | 571.65 | 20.0 | False | None | None | False | None | False | 11433.0 | 0 |
2965194 | 98022 | None | code56 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way | Each | 142.14 | 142.14 | 5.0 | False | None | None | False | None | False | 710.7 | 0 |
2965195 | 98022 | None | code57 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way | Each | 163.77 | 163.77 | 10.0 | False | None | None | False | None | False | 1637.7 | 0 |
2965196 | 98022 | None | code58 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 182.31 | 182.31 | 6.0 | False | None | None | False | None | False | 1093.86 | 0 |
2965197 | 98022 | None | code59 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 226.6 | 226.6 | 8.0 | False | None | None | False | None | False | 1812.8 | 0 |
2965198 | 98022 | None | code60 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 268.83 | 268.83 | 24.0 | False | None | None | False | None | False | 6451.92 | 0 |
2965199 | 98022 | None | code61 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12Way | Each | 328.57 | 328.57 | 18.0 | False | None | None | False | None | False | 5914.26 | 0 |
2965200 | 98022 | None | code62 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module | Each | 141.11 | 141.11 | 5.0 | False | None | None | False | None | False | 705.55 | 0 |
2965201 | 98022 | None | code63 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 165.83 | 165.83 | 10.0 | False | None | None | False | None | False | 1658.3 | 0 |
2965202 | 98022 | None | code64 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 180.25 | 180.25 | 6.0 | False | None | None | False | None | False | 1081.5 | 0 |
2965203 | 98022 | None | code65 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 241.02 | 241.02 | 8.0 | False | None | None | False | None | False | 1928.16 | 0 |
2965204 | 98022 | None | code66 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 292.52 | 292.52 | 24.0 | False | None | None | False | None | False | 7020.48 | 0 |
2965205 | 98022 | None | code67 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.10-12 Module | Each | 354.32 | 354.32 | 18.0 | False | None | None | False | None | False | 6377.76 | 0 |
2965206 | 98022 | None | code68 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch | Each | 105.06 | 105.06 | 84.0 | False | None | None | False | None | False | 8825.04 | 0 |
2965207 | 98022 | None | code69 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch | Each | 170.98 | 170.98 | 2.0 | False | None | None | False | None | False | 341.96 | 0 |
2965208 | 98022 | None | code70 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket | Each | 176.13 | 176.13 | 48.0 | False | None | None | False | None | False | 8454.24 | 0 |
2965209 | 98022 | None | code71 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Each | 367.71 | 367.71 | 6.0 | False | None | None | False | None | False | 2206.26 | 0 |
2965210 | 98022 | None | code72 | Supplyin and Fixing Metal Fan Box with Round Hook. | No | 120.51 | 120.51 | 6.0 | False | None | None | False | None | False | 723.06 | 0 |
2965211 | 98022 | None | code73 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 19/20mm dia 2mm thick | Mtr | 67.98 | 67.98 | 250.0 | False | None | None | False | None | False | 16995.0 | 0 |
2965212 | 98022 | None | code74 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 25mm dia 2mm thick | Mtr | 80.34 | 80.34 | 300.0 | False | None | None | False | None | False | 24102.0 | 0 |
2965213 | 98022 | None | code75 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) 32mm dia 2.5mm thick | Mtr | 106.09 | 106.09 | 100.0 | False | None | None | False | None | False | 10609.0 | 0 |
2965214 | 98022 | None | code76 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick | Mtr | 70.04 | 70.04 | 125.0 | False | None | None | False | None | False | 8755.0 | 0 |
2965215 | 98022 | None | code77 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 81.37 | 81.37 | 150.0 | False | None | None | False | None | False | 12205.5 | 0 |
2965216 | 98022 | None | code78 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick | Mtr | 101.97 | 101.97 | 50.0 | False | None | None | False | None | False | 5098.5 | 0 |
2965217 | 98022 | None | code79 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm | Mtr | 26.78 | 26.78 | 150.0 | False | None | None | False | None | False | 4017.0 | 0 |
2965218 | 98022 | None | code80 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm | Mtr | 43.26 | 43.26 | 330.0 | False | None | None | False | None | False | 14275.8 | 0 |
2965219 | 98022 | None | code81 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm | Mtr | 64.89 | 64.89 | 50.0 | False | None | None | False | None | False | 3244.5 | 0 |
2965220 | 98022 | None | code82 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm | Mtr | 94.76 | 94.76 | 200.0 | False | None | None | False | None | False | 18952.0 | 0 |
2965221 | 98022 | None | code83 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N | Each | 4159.14 | 4159.14 | 1.0 | False | None | None | False | None | False | 4159.14 | 0 |
2965222 | 98022 | None | code84 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP | Each | 427.45 | 427.45 | 12.0 | False | None | None | False | None | False | 5129.4 | 0 |
2965223 | 98022 | None | code85 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN | Each | 3180.64 | 3180.64 | 1.0 | False | None | None | False | None | False | 3180.64 | 0 |
2965224 | 98022 | None | code86 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole | Each | 4695.77 | 4695.77 | 1.0 | False | None | None | False | None | False | 4695.77 | 0 |
2965225 | 98022 | None | code87 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 911.55 | 911.55 | 6.0 | False | None | None | False | None | False | 5469.3 | 0 |
2965226 | 98022 | None | code88 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | Each | 710.7 | 710.7 | 12.0 | False | None | None | False | None | False | 8528.4 | 0 |
2965227 | 98022 | None | code89 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 18 W, 6500K | Each | 438.78 | 438.78 | 6.0 | False | None | None | False | None | False | 2632.68 | 0 |
2965228 | 98022 | None | code90 | Supplying & Fixing of Special Type pigmy and candle lamp. Operating voltage range from 180V to 265V, 50Hz AC power Supply | No | 53.56 | 53.56 | 6.0 | False | None | None | False | None | False | 321.36 | 0 |
2965229 | 98022 | None | code91 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) | Each | 2757.31 | 2757.31 | 6.0 | False | None | None | False | None | False | 16543.86 | 0 |
2965230 | 98022 | None | code92 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin | Each | 64.89 | 64.89 | 6.0 | False | None | None | False | None | False | 389.34 | 0 |
2965231 | 98022 | None | code93 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 125.66 | 125.66 | 18.0 | False | None | None | False | None | False | 2261.88 | 0 |
2965232 | 98022 | None | code94 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. | Each | 324.45 | 324.45 | 6.0 | False | None | None | False | None | False | 1946.7 | 0 |
2965233 | 98022 | None | code95 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle | Sqm | 404.79 | 404.79 | 7.4 | False | None | None | False | None | False | 2995.446 | 0 |
2965234 | 98022 | None | code96 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 97.85 | 97.85 | 221.85 | False | None | None | False | None | False | 21708.0225 | 0 |
2965235 | 98022 | None | code97 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 249.26 | 249.26 | 221.85 | False | None | None | False | None | False | 55298.331 | 0 |
2965236 | 98022 | None | code98 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 87.55 | 87.55 | 73.95 | False | None | None | False | None | False | 6474.3225 | 0 |
2965237 | 98022 | None | code99 | Making 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cutting | Sqm | 8.0 | 8.0 | 739.5 | False | None | None | False | None | False | 5916.0 | 0 |
2965238 | 98022 | None | code100 | Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 105.0 | 105.0 | 110.93 | False | None | None | False | None | False | 11647.65 | 0 |
2965239 | 98022 | None | code101 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 221.85 | False | None | None | False | None | False | 108311.607 | 0 |
2965240 | 98022 | None | code102 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material | Cum | 2429.77 | 2429.77 | 110.93 | False | None | None | False | None | False | 269534.3861 | 0 |
2965241 | 98022 | None | code103 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface andcompactingwithvibratoryrollertoachievethedesireddensity. | Cum | 2635.77 | 2635.77 | 147.9 | False | None | None | False | None | False | 389830.383 | 0 |
2965242 | 98022 | None | code104 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. | Sqm | 42.23 | 42.23 | 739.5 | False | None | None | False | None | False | 31229.085 | 0 |
2965243 | 98022 | None | code105 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom | Sqm | 12.36 | 12.36 | 739.5 | False | None | None | False | None | False | 9140.22 | 0 |
2965244 | 98022 | None | code106 | Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 30 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction | Cum | 7762.08 | 7762.08 | 55.46 | False | None | None | False | None | False | 430484.9568 | 0 |
2965245 | 98022 | None | code107 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. | Cum | 10456.56 | 10456.56 | 18.49 | False | None | None | False | None | False | 193341.7944 | 0 |
2965246 | 98022 | None | code108 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 6.3 | False | None | None | False | None | False | 38862.621 | 0 |
2965247 | 98022 | None | code109 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone | m | 257.5 | 257.5 | 210.0 | False | None | None | False | None | False | 54075.0 | 0 |
2965248 | 98022 | None | code110 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. | Sqm | 112.27 | 112.27 | 147.0 | False | None | None | False | None | False | 16503.69 | 0 |
2965249 | 98022 | None | code111 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle | Sqm | 404.79 | 404.79 | 0.45 | False | None | None | False | None | False | 182.1555 | 0 |
2965250 | 98022 | None | code112 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 150.0 | False | None | None | False | None | False | 15759.0 | 0 |
2965251 | 98022 | None | code113 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) | Cum | 139.05 | 139.05 | 150.0 | False | None | None | False | None | False | 20857.5 | 0 |
2965252 | 98022 | None | code114 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 12.0 | False | None | None | False | None | False | 74024.04 | 0 |
2965253 | 98022 | None | code115 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. Base slab | Cum | 7170.35 | 7170.35 | 12.0 | False | None | None | False | None | False | 86044.2 | 0 |
2965254 | 98022 | None | code116 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. Side wall | Cum | 9219.02 | 9219.02 | 22.5 | False | None | None | False | None | False | 207427.95 | 0 |
2965255 | 98022 | None | code117 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | m | 955.84 | 955.84 | 150.0 | False | None | None | False | None | False | 143376.0 | 0 |
2965256 | 98022 | None | code118 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | Tonne | 81381.33 | 81381.33 | 2.3 | False | None | None | False | None | False | 187177.059 | 0 |
2965257 | 98022 | None | code119 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle | Sqm | 404.79 | 404.79 | 3.24 | False | None | None | False | None | False | 1311.5196 | 0 |
2965258 | 98022 | None | code120 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 97.85 | 97.85 | 97.2 | False | None | None | False | None | False | 9511.02 | 0 |
2965259 | 98022 | None | code121 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 254.18 | False | None | None | False | None | False | 26704.1508 | 0 |
2965260 | 98022 | None | code122 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 254.18 | False | None | None | False | None | False | 69640.2364 | 0 |
2965261 | 98022 | None | code123 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork | Cum | 6168.67 | 6168.67 | 25.23 | False | None | None | False | None | False | 155635.5441 | 0 |
2965262 | 98022 | None | code124 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | Tonne | 81381.33 | 81381.33 | 12.52 | False | None | None | False | None | False | 1018894.2516 | 0 |
2965263 | 98022 | None | code125 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 6.36 | False | None | None | False | None | False | 40726.3236 | 0 |
2965264 | 98022 | None | code126 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. Column | Cum | 11982.09 | 11982.09 | 17.69 | False | None | None | False | None | False | 211963.1721 | 0 |
2965265 | 98022 | None | code127 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. Footing | Cum | 7612.15 | 7612.15 | 53.9 | False | None | None | False | None | False | 410294.885 | 0 |
2965266 | 98022 | None | code128 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork. Plinth Beam | Cum | 10572.44 | 10572.44 | 62.8 | False | None | None | False | None | False | 663949.232 | 0 |
2965267 | 98022 | None | code129 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 572.4 | False | None | None | False | None | False | 772339.32 | 0 |
2965268 | 98022 | None | code130 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) | Sqm | 359.47 | 359.47 | 1208.4 | False | None | None | False | None | False | 434383.548 | 0 |
2965269 | 98022 | None | code131 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kg | 140.08 | 140.08 | 712.8 | False | None | None | False | None | False | 99849.024 | 0 |
2965270 | 98022 | None | code132 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 160.68 | 160.68 | 1208.4 | False | None | None | False | None | False | 194165.712 | 0 |
2965271 | 98022 | None | code133 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 249.26 | 249.26 | 16.97 | False | None | None | False | None | False | 4229.9422 | 0 |
2965272 | 98022 | None | code134 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 m | Cum | 266.77 | 266.77 | 16.97 | False | None | None | False | None | False | 4527.0869 | 0 |
2965273 | 98022 | None | code135 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) | Cum | 139.05 | 139.05 | 33.93 | False | None | None | False | None | False | 4717.9665 | 0 |
2965274 | 98022 | None | code136 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. | Each | 1156.69 | 1156.69 | 70.0 | False | None | None | False | None | False | 80968.3 | 0 |
2965275 | 98022 | None | code137 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. | Cum | 1032.06 | 1032.06 | 11.31 | False | None | None | False | None | False | 11672.5986 | 0 |
2965276 | 98022 | None | code138 | Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer in-charge. | Cum | 1221.58 | 1221.58 | 5.66 | False | None | None | False | None | False | 6914.1428 | 0 |
2965277 | 98022 | None | code139 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.. | Cum | 1227.76 | 1227.76 | 5.66 | False | None | None | False | None | False | 6949.1216 | 0 |
2965278 | 98022 | None | code140 | Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer in-charge. | Cum | 1379.17 | 1379.17 | 5.66 | False | None | None | False | None | False | 7806.1022 | 0 |
2965279 | 98022 | None | code141 | Providing and laying 100mm thick pre-cast cover slabs over Road side drains / utility ducts / Rain water harvesting pit of width not exceeding 1000 mm using M20 concrete reinforced with TMT bars Fe 550 @ 6kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. | Sqm | 1205.1 | 1205.1 | 10.0 | False | None | None | False | None | False | 12051.0 | 0 |