tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1709811495000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK DISTRICT HOSPITAL AT MANGALURU, KARNATAKA-CIVIL WORKS | 143396837.17 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2963335 | 97969 | None | V-1 8 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.( Basement floor)
---- etc., complete with all lead | Cum | 125.55 | 125.55 | 792.0 | False | None | None | False | None | False | 99435.6 | 0 | 2963336 | 97969 | None | V-1 8 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work in all kinds of soils Depth upto 3 m.( Basement floor)
---- etc., complete with all lead | Cum | 134.8 | 134.8 | 2328.09 | False | None | None | False | None | False | 313826.532 | 0 | 2963337 | 97969 | None | V-3 3 1.1A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.( Basement floor)
---- etc., complete with all lead | Cum | 178.42 | 178.42 | 1264.05 | False | None | None | False | None | False | 225531.801 | 0 | 2963338 | 97969 | None | V-2 5 4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.( Basement floor)
---- etc., complete with all lead | Sqm | 155.95 | 155.95 | 1300.0 | False | None | None | False | None | False | 202735.0 | 0 | 2963339 | 97969 | None | V-1 7 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.( Basement floor)
---- etc., complete with all lead | Cum | 351.55 | 351.55 | 1164.05 | False | None | None | False | None | False | 409221.7775 | 0 | 2963340 | 97969 | None | V-1 7 1.8 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.( Basement floor)
---- etc., complete with all lead | Cum | 626.44 | 626.44 | 442.74 | False | None | None | False | None | False | 277350.0456 | 0 | 2963341 | 97969 | None | V-1 15 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ( Basement floor)
---- etc., complete with all lead | Cum | 7915.06 | 7915.06 | 277.87 | False | None | None | False | None | False | 2199357.7222 | 0 | 2963342 | 97969 | None | V-1 15 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork ( Basement floor)FOOTINGS
---- etc., complete with all lead | Cum | 8973.61 | 8973.61 | 743.58 | False | None | None | False | None | False | 6672596.9238 | 0 | 2963343 | 97969 | None | V-1 15 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork ( Basement floor)
PEDESTALS
---- etc., complete with all lead | Cum | 9139.79 | 9139.79 | 21.2 | False | None | None | False | None | False | 193763.548 | 0 | 2963344 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
COLUMNS
---- etc., complete with all lead | Cum | 15374.3 | 15374.3 | 69.42 | False | None | None | False | None | False | 1067283.906 | 0 | 2963345 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
LIFT CORE WALL
---- etc., complete with all lead | Cum | 9948.08 | 9948.08 | 108.04 | False | None | None | False | None | False | 1074790.5632 | 0 | 2963346 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
PLINTH BEAM
---- etc., complete with all lead | Cum | 13565.56 | 13565.56 | 68.65 | False | None | None | False | None | False | 931275.694 | 0 | 2963347 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
RCC BEAMS
---- etc., complete with all lead | Cum | 14469.93 | 14469.93 | 138.56 | False | None | None | False | None | False | 2004953.5008 | 0 | 2963348 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
RCC Slab ---- etc., complete with all lead | Cum | 13565.56 | 13565.56 | 151.14 | False | None | None | False | None | False | 2050298.7384 | 0 | 2963349 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
RCC STAIRCASE
---- etc., complete with all lead | Cum | 13565.56 | 13565.56 | 15.99 | False | None | None | False | None | False | 216913.3044 | 0 | 2963350 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Basement floor)
LINTELS
---- etc., complete with all lead | Cum | 14469.93 | 14469.93 | 1.78 | False | None | None | False | None | False | 25756.4754 | 0 | 2963351 | 97969 | None | V-1 16 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for cills ( Basement floor)
---- etc., complete with all lead | Cum | 12705.2 | 12705.2 | 2.82 | False | None | None | False | None | False | 35828.664 | 0 | 2963352 | 97969 | None | V-2 43 8.16 a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.( Basement floor)
---- etc., complete with all lead | Sqm | 1636.14 | 1636.14 | 10.8 | False | None | None | False | None | False | 17670.312 | 0 | 2963353 | 97969 | None | V-1 18 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification for Building .( Basement floor)
---- etc., complete with all lead | Tonne | 118226.37 | 118226.37 | 141.23 | False | None | None | False | None | False | 16697110.2351 | 0 | 2963354 | 97969 | None | 18-19 SR 15 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications.( Basement floor)
---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 63.8 | False | None | None | False | None | False | 2484.372 | 0 | 2963355 | 97969 | None | V-2 9 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.( Basement floor)
---- etc., complete with all lead | Cum | 8927.41 | 8927.41 | 160.92 | False | None | None | False | None | False | 1436598.8172 | 0 | 2963356 | 97969 | None | V-2 17 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.( Basement floor)
---- etc., complete with all lead | Sqm | 1459.05 | 1459.05 | 72.81 | False | None | None | False | None | False | 106233.4305 | 0 | 2963357 | 97969 | None | V-2 105 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ( Basement floor)
---- etc., complete with all lead | Sqm | 4390.36 | 4390.36 | 26.64 | False | None | None | False | None | False | 116959.1904 | 0 | 2963358 | 97969 | None | V-2 100 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ( Basement floor)
---- etc., complete with all lead | Cum | 130593.9 | 130593.9 | 0.6 | False | None | None | False | None | False | 78356.34 | 0 | 2963359 | 97969 | None | V-2 105 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ( Basement floor)
---- etc., complete with all lead | Nos | 1342.75 | 1342.75 | 7.0 | False | None | None | False | None | False | 9399.25 | 0 | 2963360 | 97969 | None | V-2 218 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ( Basement floor)
---- etc., complete with all lead | No | 726.88 | 726.88 | 14.0 | False | None | None | False | None | False | 10176.32 | 0 | 2963361 | 97969 | None | V-2 219 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ( Basement floor)
---- etc., complete with all lead | No | 495.6 | 495.6 | 19.0 | False | None | None | False | None | False | 9416.4 | 0 | 2963362 | 97969 | None | V-2 219 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ( Basement floor)
---- etc., complete with all lead | No | 198.24 | 198.24 | 14.0 | False | None | None | False | None | False | 2775.36 | 0 | 2963363 | 97969 | None | V-2 219 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ( Basement floor)
---- etc., complete with all lead | No | 92.51 | 92.51 | 28.0 | False | None | None | False | None | False | 2590.28 | 0 | 2963364 | 97969 | None | V-2 219 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ( Basement floor)
---- etc., complete with all lead | No | 132.16 | 132.16 | 7.0 | False | None | None | False | None | False | 925.12 | 0 | 2963365 | 97969 | None | V-2 105 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.( Basement floor)
---- etc., complete with all lead | No | 1390.32 | 1390.32 | 7.0 | False | None | None | False | None | False | 9732.24 | 0 | 2963366 | 97969 | None | V-2 69 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ( Basement floor)
---- etc., complete with all lead | Nos | 79.3 | 79.3 | 42.0 | False | None | None | False | None | False | 3330.6 | 0 | 2963367 | 97969 | None | V-2 110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC Matching to RAL- 9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free, gaskets - grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made
Basement floor
---- etc., complete with all lead | Sqm | 8899.65 | 8899.65 | 15.66 | False | None | None | False | None | False | 139368.519 | 0 | 2963368 | 97969 | None | V-2 109 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( Basement floor)
---- etc., complete with all lead | Sqm | 7558.23 | 7558.23 | 5.94 | False | None | None | False | None | False | 44895.8862 | 0 | 2963369 | 97969 | None | V-2 86 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ( Basement floor)
---- etc., complete with all lead | Kg | 222.03 | 222.03 | 453.6 | False | None | None | False | None | False | 100712.808 | 0 | 2963370 | 97969 | None | V-2 111 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ( Basement floor)
---- etc., complete with all lead | m | 927.76 | 927.76 | 18.0 | False | None | None | False | None | False | 16699.68 | 0 | 2963371 | 97969 | None | V-2 112 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ( Basement floor)
---- etc., complete with all lead | Sqm | 4605.78 | 4605.78 | 5.67 | False | None | None | False | None | False | 26114.7726 | 0 | 2963372 | 97969 | None | V-2 107 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.( Basement floor)
---- etc., complete with all lead | Nos | 1472.26 | 1472.26 | 17.0 | False | None | None | False | None | False | 25028.42 | 0 | 2963373 | 97969 | None | V-2 109 11.25.2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Basement floor)
---- etc., complete with all lead | Kgs | 179.74 | 179.74 | 504.0 | False | None | None | False | None | False | 90588.96 | 0 | 2963374 | 97969 | None | V-2 41 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ( Basement floor)
---- etc., complete with all lead | Sqm | 412.34 | 412.34 | 705.06 | False | None | None | False | None | False | 290724.4404 | 0 | 2963375 | 97969 | None | V-2 43 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 278.86 | 278.86 | 1861.92 | False | None | None | False | None | False | 519215.0112 | 0 | 2963376 | 97969 | None | V-2 50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.( Basement floor)
---- etc., complete with all lead | Sqm | 132.16 | 132.16 | 2567.0 | False | None | None | False | None | False | 339254.72 | 0 | 2963377 | 97969 | None | V-2 42 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ( Basement floor)
---- etc., complete with all lead | Sqm | 461.24 | 461.24 | 633.6 | False | None | None | False | None | False | 292241.664 | 0 | 2963378 | 97969 | None | V-2 41 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 467.85 | 467.85 | 86.35 | False | None | None | False | None | False | 40398.8475 | 0 | 2963379 | 97969 | None | V-2 43 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ( Basement floor)
---- etc., complete with all lead | Rmtr | 50.22 | 50.22 | 3720.0 | False | None | None | False | None | False | 186818.4 | 0 | 2963380 | 97969 | None | V-2 54 8.79 |
Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.( Basement floor)
---- etc., complete with all lead | Rmtr | 68.72 | 68.72 | 800.8 | False | None | None | False | None | False | 55030.976 | 0 | 2963381 | 97969 | None | V-2 61 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ( Basement floor)
---- etc., complete with all lead | Sqm | 1552.88 | 1552.88 | 404.75 | False | None | None | False | None | False | 628528.18 | 0 | 2963382 | 97969 | None | V-2 62 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ( Basement floor)
---- etc., complete with all lead | Sqm | 1752.44 | 1752.44 | 180.24 | False | None | None | False | None | False | 315859.7856 | 0 | 2963383 | 97969 | None | V-2 64 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ( Basement floor)
---- etc., complete with all lead | Sqm | 7041.48 | 7041.48 | 97.02 | False | None | None | False | None | False | 683164.3896 | 0 | 2963384 | 97969 | None | V-2 64 9.32 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.( Basement floor)
---- etc., complete with all lead | Sqm | 3412.37 | 3412.37 | 43.61 | False | None | None | False | None | False | 148813.4557 | 0 | 2963385 | 97969 | None | V-2 41 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 389.87 | 389.87 | 212.97 | False | None | None | False | None | False | 83030.6139 | 0 | 2963386 | 97969 | None | V-2 150 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ( Basement floor)
---- etc., complete with all lead | Sqm | 812.78 | 812.78 | 12.78 | False | None | None | False | None | False | 10387.3284 | 0 | 2963387 | 97969 | None | V-2 60 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.( Basement floor)
---- etc., complete with all lead | Sqm | 1174.9 | 1174.9 | 7.98 | False | None | None | False | None | False | 9375.702 | 0 | 2963388 | 97969 | None | V-2 65 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.( Basement floor)
---- etc., complete with all lead | Sqm | 1915.0 | 1915.0 | 32.73 | False | None | None | False | None | False | 62677.95 | 0 | 2963389 | 97969 | None | V-2 85 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( Basement floor)
---- etc., complete with all lead | Kg | 746.7 | 746.7 | 352.8 | False | None | None | False | None | False | 263435.76 | 0 | 2963390 | 97969 | None | V-2 48 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 167.84 | 167.84 | 2566.98 | False | None | None | False | None | False | 430841.9232 | 0 | 2963391 | 97969 | None | V-2 46 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 206.17 | 206.17 | 633.6 | False | None | None | False | None | False | 130629.312 | 0 | 2963392 | 97969 | None | V-2 47 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 66.08 | 66.08 | 21.6 | False | None | None | False | None | False | 1427.328 | 0 | 2963393 | 97969 | None | V-2 48 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 151.98 | 151.98 | 21.6 | False | None | None | False | None | False | 3282.768 | 0 | 2963394 | 97969 | None | V-2 47 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Basement floor)
---- etc., complete with all lead | Sqm | 70.04 | 70.04 | 63.94 | False | None | None | False | None | False | 4478.3576 | 0 | 2963395 | 97969 | None | V-2 54 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ( Basement floor)"
---- etc., complete with all lead | Sqm | 894.72 | 894.72 | 63.94 | False | None | None | False | None | False | 57208.3968 | 0 | 2963396 | 97969 | None | V-2 25 7.31 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications.( Basement floor)
---- etc., complete with all lead | Sqm | 1683.72 | 1683.72 | 121.4 | False | None | None | False | None | False | 204403.608 | 0 | 2963397 | 97969 | None | V-2 28 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling
with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.( Basement floor)
---- etc., complete with all lead | Sqm | 2237.47 | 2237.47 | 182.1 | False | None | None | False | None | False | 407443.287 | 0 | 2963398 | 97969 | None | V-2 69 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ( Basement floor)
---- etc., complete with all lead | Sqm | 5294.33 | 5294.33 | 3.24 | False | None | None | False | None | False | 17153.6292 | 0 | 2963399 | 97969 | None | Data rate | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete.( Basement floor)
---- etc., complete with all lead | Rmtr | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 | 2963400 | 97969 | None | V-1 (CPWD) 205 9.136 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately).( Basement floor)
---- etc., complete with all lead | m | 1541.11 | 1541.11 | 288.0 | False | None | None | False | None | False | 443839.68 | 0 | 2963401 | 97969 | None | V-1 (CPWD) 205 9.137 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately).( Basement floor)
---- etc., complete with all lead | Sqm | 6790.22 | 6790.22 | 94.68 | False | None | None | False | None | False | 642898.0296 | 0 | 2963402 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Ground floor) COLUMNS
---- etc., complete with all lead | Cum | 15374.3 | 15374.3 | 63.18 | False | None | None | False | None | False | 971348.274 | 0 | 2963403 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Ground floor)
LIFT CORE WALL
---- etc., complete with all lead | Cum | 15374.3 | 15374.3 | 17.17 | False | None | None | False | None | False | 263976.731 | 0 | 2963404 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Ground floor)
RCC BEAMS
---- etc., complete with all lead | Cum | 14469.93 | 14469.93 | 138.56 | False | None | None | False | None | False | 2004953.5008 | 0 | 2963405 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Ground floor)
RCC SLAB
---- etc., complete with all lead | Cum | 13565.56 | 13565.56 | 151.14 | False | None | None | False | None | False | 2050298.7384 | 0 | 2963406 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Ground floor)
RCC STAIRCASE
---- etc., complete with all lead | Cum | 13565.56 | 13565.56 | 15.54 | False | None | None | False | None | False | 210808.8024 | 0 | 2963407 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( Ground floor)
LINTELS
---- etc., complete with all lead | Cum | 14469.93 | 14469.93 | 5.53 | False | None | None | False | None | False | 80018.7129 | 0 | 2963408 | 97969 | None | V-1 16 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for cills ( Ground floor)
---- etc., complete with all lead | Cum | 12705.2 | 12705.2 | 5.58 | False | None | None | False | None | False | 70895.016 | 0 | 2963409 | 97969 | None | V-2 43 8.16 a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ( Ground floor)
---- etc., complete with all lead | Sqm | 1636.14 | 1636.14 | 11.7 | False | None | None | False | None | False | 19142.838 | 0 | 2963410 | 97969 | None | V-1 18 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ( Ground floor)
---- etc., complete with all lead | Tonne | 118226.37 | 118226.37 | 58.7 | False | None | None | False | None | False | 6939887.919 | 0 | 2963411 | 97969 | None | 18-19 SR 15 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ( Ground floor)
---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 134.7 | False | None | None | False | None | False | 5245.218 | 0 | 2963412 | 97969 | None | Data RateV-2 9 5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)( Ground floor)
---- etc., complete with all lead | Cum | 8443.7 | 8443.7 | 7.22 | False | None | None | False | None | False | 60963.514 | 0 | 2963413 | 97969 | None | V-2 9 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.( Ground floor)
---- etc., complete with all lead | Cum | 8927.41 | 8927.41 | 334.55 | False | None | None | False | None | False | 2986665.0155 | 0 | 2963414 | 97969 | None | V-2 17 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.( Ground floor)
---- etc., complete with all lead | Sqm | 1459.05 | 1459.05 | 264.42 | False | None | None | False | None | False | 385802.001 | 0 | 2963415 | 97969 | None | V-2 93 11.52 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Ground floor)
---- etc., complete with all lead | Sqm | 6240.6 | 6240.6 | 4.8 | False | None | None | False | None | False | 29954.88 | 0 | 2963416 | 97969 | None | V-2 105 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ( Ground floor)
---- etc., complete with all lead | Sqm | 4390.36 | 4390.36 | 103.2 | False | None | None | False | None | False | 453085.152 | 0 | 2963417 | 97969 | None | V-2 100 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.( Ground floor)
---- etc., complete with all lead | Cum | 130593.9 | 130593.9 | 2.93 | False | None | None | False | None | False | 382640.127 | 0 | 2963418 | 97969 | None | V-2 105 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.( Ground floor)
---- etc., complete with all lead | Nos | 1342.75 | 1342.75 | 29.0 | False | None | None | False | None | False | 38939.75 | 0 | 2963419 | 97969 | None | V-2 218 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm ( Ground floor)
---- etc., complete with all lead | No | 726.88 | 726.88 | 58.0 | False | None | None | False | None | False | 42159.04 | 0 | 2963420 | 97969 | None | V-2 219 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ( Ground floor)
---- etc., complete with all lead | No | 495.6 | 495.6 | 29.0 | False | None | None | False | None | False | 14372.4 | 0 | 2963421 | 97969 | None | V-2 219 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ( Ground floor)
---- etc., complete with all lead | No | 198.24 | 198.24 | 57.0 | False | None | None | False | None | False | 11299.68 | 0 | 2963422 | 97969 | None | V-2 219 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ( Ground floor)
---- etc., complete with all lead | No | 92.51 | 92.51 | 105.0 | False | None | None | False | None | False | 9713.55 | 0 | 2963423 | 97969 | None | V-2 219 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ( Ground floor)
---- etc., complete with all lead | No | 132.16 | 132.16 | 29.0 | False | None | None | False | None | False | 3832.64 | 0 | 2963424 | 97969 | None | V-2 105 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ( Ground floor)
---- etc., complete with all lead | No | 1390.32 | 1390.32 | 29.0 | False | None | None | False | None | False | 40319.28 | 0 | 2963425 | 97969 | None | V-2 69 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ( Ground floor)
---- etc., complete with all lead | Nos | 79.3 | 79.3 | 174.0 | False | None | None | False | None | False | 13798.2 | 0 | 2963426 | 97969 | None | Data Rate | Providing & Fixing of corner beads of wooden door frame to wall including cost of materials, labour charges, complete as per specifications. ( Ground floor)
---- etc., complete with all lead | Rmtr | 15.0 | 15.0 | 182.2 | False | None | None | False | None | False | 2733.0 | 0 | 2963427 | 97969 | None | V-2 110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( Ground floor)
---- etc., complete with all lead | Sqm | 8899.65 | 8899.65 | 67.8 | False | None | None | False | None | False | 603396.27 | 0 | 2963428 | 97969 | None | V-2 109 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( Ground floor)
---- etc., complete with all lead | Sqm | 7558.23 | 7558.23 | 8.1 | False | None | None | False | None | False | 61221.663 | 0 | 2963429 | 97969 | None | V-2 86 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ( Ground floor)
---- etc., complete with all lead | Kg | 222.03 | 222.03 | 1593.9 | False | None | None | False | None | False | 353893.617 | 0 | 2963430 | 97969 | None | V-2 111 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ( Ground floor)
---- etc., complete with all lead | m | 927.76 | 927.76 | 60.0 | False | None | None | False | None | False | 55665.6 | 0 | 2963431 | 97969 | None | V-2 112 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ( Ground floor)
---- etc., complete with all lead | Sqm | 4605.78 | 4605.78 | 18.9 | False | None | None | False | None | False | 87049.242 | 0 | 2963432 | 97969 | None | V-2 107 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ( Ground floor)
---- etc., complete with all lead | Nos | 1472.26 | 1472.26 | 39.0 | False | None | None | False | None | False | 57418.14 | 0 | 2963433 | 97969 | None | V-2 41 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ( Ground floor)
---- etc., complete with all lead | Sqm | 412.34 | 412.34 | 2981.0 | False | None | None | False | None | False | 1229185.54 | 0 | 2963434 | 97969 | None | V-2 43 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 278.86 | 278.86 | 1861.92 | False | None | None | False | None | False | 519215.0112 | 0 | 2963435 | 97969 | None | V-2 50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 132.16 | 132.16 | 4842.93 | False | None | None | False | None | False | 640041.6288 | 0 | 2963436 | 97969 | None | V-2 42 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ( Ground floor)
---- etc., complete with all lead | Sqm | 461.24 | 461.24 | 601.8 | False | None | None | False | None | False | 277574.232 | 0 | 2963437 | 97969 | None | V-2 41 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 467.85 | 467.85 | 87.6 | False | None | None | False | None | False | 40983.66 | 0 | 2963438 | 97969 | None | V-2 43 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ( Ground floor)
---- etc., complete with all lead | Rmtr | 50.22 | 50.22 | 4200.0 | False | None | None | False | None | False | 210924.0 | 0 | 2963439 | 97969 | None | 18-19 SR 69 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer.( Ground floor)
---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 2963440 | 97969 | None | V-2 54 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.( Ground floor)
---- etc., complete with all lead | Rmtr | 68.72 | 68.72 | 800.8 | False | None | None | False | None | False | 55030.976 | 0 | 2963441 | 97969 | None | V-2 61 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ( Ground floor)
---- etc., complete with all lead | Sqm | 1552.88 | 1552.88 | 959.17 | False | None | None | False | None | False | 1489475.9096 | 0 | 2963442 | 97969 | None | V-2 59 9.1 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.( Ground floor)
---- etc., complete with all lead | Sqm | 596.04 | 596.04 | 96.0 | False | None | None | False | None | False | 57219.84 | 0 | 2963443 | 97969 | None | V-2 62 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ( Ground floor)
---- etc., complete with all lead | Sqm | 1752.44 | 1752.44 | 542.76 | False | None | None | False | None | False | 951154.3344 | 0 | 2963444 | 97969 | None | V-2 64 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ( Ground floor)
---- etc., complete with all lead | Sqm | 7041.48 | 7041.48 | 97.02 | False | None | None | False | None | False | 683164.3896 | 0 | 2963445 | 97969 | None | V-2 41 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 389.87 | 389.87 | 817.02 | False | None | None | False | None | False | 318531.5874 | 0 | 2963446 | 97969 | None | V-2 150 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ( Ground floor)
---- etc., complete with all lead | Sqm | 812.78 | 812.78 | 127.03 | False | None | None | False | None | False | 103247.4434 | 0 | 2963447 | 97969 | None | V-2 23 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ( Ground floor)
---- etc., complete with all lead | Cum | 2665.67 | 2665.67 | 24.47 | False | None | None | False | None | False | 65228.9449 | 0 | 2963448 | 97969 | None | V-2 60 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ( Ground floor)
---- etc., complete with all lead | Sqm | 1174.9 | 1174.9 | 89.12 | False | None | None | False | None | False | 104707.088 | 0 | 2963449 | 97969 | None | V-2 65 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ( Ground floor)
---- etc., complete with all lead | Sqm | 1915.0 | 1915.0 | 274.26 | False | None | None | False | None | False | 525207.9 | 0 | 2963450 | 97969 | None | V-2 85 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.( Ground floor)
---- etc., complete with all lead | Kg | 746.7 | 746.7 | 352.8 | False | None | None | False | None | False | 263435.76 | 0 | 2963451 | 97969 | None | V-2 48 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 167.84 | 167.84 | 4842.93 | False | None | None | False | None | False | 812837.3712 | 0 | 2963452 | 97969 | None | V-2 46 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 206.17 | 206.17 | 601.8 | False | None | None | False | None | False | 124073.106 | 0 | 2963453 | 97969 | None | V-2 47 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Ground floor)
---- etc., complete with all lead | Sqm | 66.08 | 66.08 | 75.9 | False | None | None | False | None | False | 5015.472 | 0 | 2963454 | 97969 | None | V-2 48 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.( Ground floor)
---- etc., complete with all lead | Sqm | 151.98 | 151.98 | 75.9 | False | None | None | False | None | False | 11535.282 | 0 | 2963455 | 97969 | None | V-2 47 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 70.04 | 70.04 | 247.68 | False | None | None | False | None | False | 17347.5072 | 0 | 2963456 | 97969 | None | V-2 54 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ( Ground floor)
---- etc., complete with all lead | Sqm | 894.72 | 894.72 | 247.68 | False | None | None | False | None | False | 221604.2496 | 0 | 2963457 | 97969 | None | V-2 181 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ( Ground floor)
---- etc., complete with all lead | Kg | 537.89 | 537.89 | 1316.25 | False | None | None | False | None | False | 707997.7125 | 0 | 2963458 | 97969 | None | V-2 183 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ( Ground floor)
---- etc., complete with all lead | Sqm | 4021.63 | 4021.63 | 150.0 | False | None | None | False | None | False | 603244.5 | 0 | 2963459 | 97969 | None | V-2 183 18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 5495.21 | 5495.21 | 60.0 | False | None | None | False | None | False | 329712.6 | 0 | 2963460 | 97969 | None | V-2 25 7.31 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ( Ground floor)
---- etc., complete with all lead | Sqm | 1683.72 | 1683.72 | 208.16 | False | None | None | False | None | False | 350483.1552 | 0 | 2963461 | 97969 | None | V-2 28 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ( Ground floor)
---- etc., complete with all lead | Sqm | 2237.47 | 2237.47 | 312.24 | False | None | None | False | None | False | 698627.6328 | 0 | 2963462 | 97969 | None | V-2 69 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ( Ground floor)
---- etc., complete with all lead | Sqm | 5294.33 | 5294.33 | 66.61 | False | None | None | False | None | False | 352655.3213 | 0 | 2963463 | 97969 | None | V-1 1 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( First Floor)COLUMNS
---- etc., complete with all lead | Cum | 15528.05 | 15528.05 | 63.18 | False | None | None | False | None | False | 981062.199 | 0 | 2963464 | 97969 | None | V-1 1 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( First Floor)
LIFT CORE WALL
---- etc., complete with all lead | Cum | 15528.05 | 15528.05 | 13.69 | False | None | None | False | None | False | 212579.0045 | 0 | 2963465 | 97969 | None | V-1 1 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( First Floor)
RCC BEAMS
---- etc., complete with all lead | Cum | 14614.63 | 14614.63 | 148.1 | False | None | None | False | None | False | 2164426.703 | 0 | 2963466 | 97969 | None | V-1 1 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( First Floor)RCC SLAB
---- etc., complete with all lead | Cum | 13701.22 | 13701.22 | 149.73 | False | None | None | False | None | False | 2051483.6706 | 0 | 2963467 | 97969 | None | V-1 1 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( First Floor)
RCC STAIRCASE
---- etc., complete with all lead | Cum | 13701.22 | 13701.22 | 15.54 | False | None | None | False | None | False | 212916.9588 | 0 | 2963468 | 97969 | None | V-1 1 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( First Floor)
LINTELS
---- etc., complete with all lead | Cum | 14614.63 | 14614.63 | 6.44 | False | None | None | False | None | False | 94118.2172 | 0 | 2963469 | 97969 | None | V-1 2 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for cills ( First Floor)
---- etc., complete with all lead | Cum | 12832.25 | 12832.25 | 6.59 | False | None | None | False | None | False | 84564.5275 | 0 | 2963470 | 97969 | None | V-1 3 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ( First Floor)
---- etc., complete with all lead | Tonne | 119408.63 | 119408.63 | 63.95 | False | None | None | False | None | False | 7636181.8885 | 0 | 2963471 | 97969 | None | 18-19 SR 4 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ( First Floor)
---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 165.0 | False | None | None | False | None | False | 6425.1 | 0 | 2963472 | 97969 | None | V-2 6 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. ( First Floor)
---- etc., complete with all lead | Cum | 9016.68 | 9016.68 | 314.18 | False | None | None | False | None | False | 2832860.5224 | 0 | 2963473 | 97969 | None | V-2 7 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( First Floor)
---- etc., complete with all lead | Sqm | 1473.64 | 1473.64 | 217.8 | False | None | None | False | None | False | 320958.792 | 0 | 2963474 | 97969 | None | V-2 8 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ( First Floor)
---- etc., complete with all lead | Sqm | 4434.26 | 4434.26 | 100.56 | False | None | None | False | None | False | 445909.1856 | 0 | 2963475 | 97969 | None | V-2 9 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ( First Floor)
---- etc., complete with all lead | Cum | 131899.84 | 131899.84 | 2.92 | False | None | None | False | None | False | 385147.5328 | 0 | 2963476 | 97969 | None | V-2 10 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ( First Floor)
---- etc., complete with all lead | Nos | 1356.17 | 1356.17 | 31.0 | False | None | None | False | None | False | 42041.27 | 0 | 2963477 | 97969 | None | V-2 11 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm ( First Floor)
---- etc., complete with all lead | No | 734.15 | 734.15 | 62.0 | False | None | None | False | None | False | 45517.3 | 0 | 2963478 | 97969 | None | V-2 12 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ( First Floor)
---- etc., complete with all lead | No | 500.56 | 500.56 | 31.0 | False | None | None | False | None | False | 15517.36 | 0 | 2963479 | 97969 | None | V-2 13 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ( First Floor)
---- etc., complete with all lead | No | 200.22 | 200.22 | 43.0 | False | None | None | False | None | False | 8609.46 | 0 | 2963480 | 97969 | None | V-2 14 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ( First Floor)
---- etc., complete with all lead | No | 93.44 | 93.44 | 103.0 | False | None | None | False | None | False | 9624.32 | 0 | 2963481 | 97969 | None | V-2 15 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ( First Floor)
---- etc., complete with all lead | No | 133.48 | 133.48 | 31.0 | False | None | None | False | None | False | 4137.88 | 0 | 2963482 | 97969 | None | V-2 16 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ( First Floor)
---- etc., complete with all lead | No | 1404.23 | 1404.23 | 31.0 | False | None | None | False | None | False | 43531.13 | 0 | 2963483 | 97969 | None | V-2 17 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ( First Floor)
---- etc., complete with all lead | Nos | 80.09 | 80.09 | 186.0 | False | None | None | False | None | False | 14896.74 | 0 | 2963484 | 97969 | None | V-2 19 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( First Floor)
---- etc., complete with all lead | Sqm | 8988.65 | 8988.65 | 79.44 | False | None | None | False | None | False | 714058.356 | 0 | 2963485 | 97969 | None | V-2 20 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( First Floor)
---- etc., complete with all lead | Sqm | 7633.81 | 7633.81 | 16.2 | False | None | None | False | None | False | 123667.722 | 0 | 2963486 | 97969 | None | V-2 21 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ( First Floor)
---- etc., complete with all lead | Kg | 224.25 | 224.25 | 2008.44 | False | None | None | False | None | False | 450392.67 | 0 | 2963487 | 97969 | None | V-2 22 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ( First Floor)
---- etc., complete with all lead | m | 937.04 | 937.04 | 48.0 | False | None | None | False | None | False | 44977.92 | 0 | 2963488 | 97969 | None | V-2 23 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ( First Floor)
---- etc., complete with all lead | Sqm | 4651.83 | 4651.83 | 15.12 | False | None | None | False | None | False | 70335.6696 | 0 | 2963489 | 97969 | None | V-2 24 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ( First Floor)
---- etc., complete with all lead | Nos | 1486.99 | 1486.99 | 41.0 | False | None | None | False | None | False | 60966.59 | 0 | 2963490 | 97969 | None | V-2 25 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ( First Floor)
---- etc., complete with all lead | Sqm | 416.46 | 416.46 | 3109.4 | False | None | None | False | None | False | 1294940.724 | 0 | 2963491 | 97969 | None | V-2 26 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 281.65 | 281.65 | 1878.67 | False | None | None | False | None | False | 529127.4055 | 0 | 2963492 | 97969 | None | V-2 27 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ( First Floor)
---- etc., complete with all lead | Sqm | 133.48 | 133.48 | 4988.07 | False | None | None | False | None | False | 665807.5836 | 0 | 2963493 | 97969 | None | V-2 28 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ( First Floor)
---- etc., complete with all lead | Sqm | 465.85 | 465.85 | 586.86 | False | None | None | False | None | False | 273388.731 | 0 | 2963494 | 97969 | None | V-2 29 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 472.52 | 472.52 | 87.6 | False | None | None | False | None | False | 41392.752 | 0 | 2963495 | 97969 | None | V-2 30 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ( First Floor)
---- etc., complete with all lead | Rmtr | 50.72 | 50.72 | 4200.0 | False | None | None | False | None | False | 213024.0 | 0 | 2963496 | 97969 | None | 18-19 SR 31 10.5.2 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ( First Floor)
---- etc., complete with all lead | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 2963497 | 97969 | None | V-2 32 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ( First Floor)
---- etc., complete with all lead | Rmtr | 69.41 | 69.41 | 800.8 | False | None | None | False | None | False | 55583.528 | 0 | 2963498 | 97969 | None | V-2 33 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ( First Floor)
---- etc., complete with all lead | Sqm | 1568.41 | 1568.41 | 973.65 | False | None | None | False | None | False | 1527082.3965 | 0 | 2963499 | 97969 | None | V-2 34 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ( First Floor)
---- etc., complete with all lead | Sqm | 1769.97 | 1769.97 | 268.92 | False | None | None | False | None | False | 475980.3324 | 0 | 2963500 | 97969 | None | V-2 35 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ( First Floor)
---- etc., complete with all lead | Sqm | 7111.9 | 7111.9 | 97.02 | False | None | None | False | None | False | 689996.538 | 0 | 2963501 | 97969 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
---- etc., complete with all lead | Sqm | 393.77 | 393.77 | 584.04 | False | None | None | False | None | False | 229977.4308 | 0 | 2963502 | 97969 | None | 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ( First Floor)
---- etc., complete with all lead | Sqm | 820.91 | 820.91 | 142.26 | False | None | None | False | None | False | 116782.6566 | 0 | 2963503 | 97969 | None | 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ( First Floor)
---- etc., complete with all lead | Cum | 2692.32 | 2692.32 | 30.29 | False | None | None | False | None | False | 81550.3728 | 0 | 2963504 | 97969 | None | 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ( First Floor)
---- etc., complete with all lead | Sqm | 1186.65 | 1186.65 | 100.98 | False | None | None | False | None | False | 119827.917 | 0 | 2963505 | 97969 | None | 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ( First Floor)
---- etc., complete with all lead | Sqm | 1934.15 | 1934.15 | 315.12 | False | None | None | False | None | False | 609489.348 | 0 | 2963506 | 97969 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( First Floor)
---- etc., complete with all lead | Kg | 754.17 | 754.17 | 352.8 | False | None | None | False | None | False | 266071.176 | 0 | 2963507 | 97969 | None | 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 169.52 | 169.52 | 4988.07 | False | None | None | False | None | False | 845577.6264 | 0 | 2963508 | 97969 | None | 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 208.23 | 208.23 | 586.86 | False | None | None | False | None | False | 122201.8578 | 0 | 2963509 | 97969 | None | 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 66.74 | 66.74 | 95.64 | False | None | None | False | None | False | 6383.0136 | 0 | 2963510 | 97969 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 153.5 | 153.5 | 95.64 | False | None | None | False | None | False | 14680.74 | 0 | 2963511 | 97969 | None | 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( First Floor)
---- etc., complete with all lead | Sqm | 70.75 | 70.75 | 241.34 | False | None | None | False | None | False | 17074.805 | 0 | 2963512 | 97969 | None | 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ( First Floor)
---- etc., complete with all lead | Sqm | 903.67 | 903.67 | 241.34 | False | None | None | False | None | False | 218091.7178 | 0 | 2963513 | 97969 | None | 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ( First Floor)
---- etc., complete with all lead | Kg | 543.27 | 543.27 | 1316.25 | False | None | None | False | None | False | 715079.1375 | 0 | 2963514 | 97969 | None | 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface no 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face no. 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face no. 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ( First Floor) ---- etc., complete with all lead | Sqm | 4061.85 | 4061.85 | 150.0 | False | None | None | False | None | False | 609277.5 | 0 | 2963515 | 97969 | None | 18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ( First Floor)
---- etc., complete with all lead | Sqm | 5550.16 | 5550.16 | 60.0 | False | None | None | False | None | False | 333009.6 | 0 | 2963516 | 97969 | None | 7.31 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ( First Floor)
---- etc., complete with all lead | Sqm | 1700.56 | 1700.56 | 93.34 | False | None | None | False | None | False | 158730.2704 | 0 | 2963517 | 97969 | None | 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ( First Floor)
---- etc., complete with all lead | Sqm | 2259.84 | 2259.84 | 140.0 | False | None | None | False | None | False | 316377.6 | 0 | 2963518 | 97969 | None | 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ( First Floor)
---- etc., complete with all lead | Sqm | 5347.27 | 5347.27 | 66.61 | False | None | None | False | None | False | 356181.6547 | 0 | 2963519 | 97969 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( SECOND FLOOR) For COLUMNS
---- etc., complete with all lead | Cum | 15681.79 | 15681.79 | 63.18 | False | None | None | False | None | False | 990775.4922 | 0 | 2963520 | 97969 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( SECOND FLOOR) For LIFT CORE WALL
---- etc., complete with all lead | Cum | 15681.79 | 15681.79 | 13.69 | False | None | None | False | None | False | 214683.7051 | 0 | 2963521 | 97969 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( SECOND FLOOR) For RCC BEAMS
---- etc., complete with all lead | Cum | 14759.33 | 14759.33 | 148.1 | False | None | None | False | None | False | 2185856.773 | 0 | 2963522 | 97969 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( SECOND FLOOR) For RCC SLAB
---- etc., complete with all lead | Cum | 13836.87 | 13836.87 | 155.35 | False | None | None | False | None | False | 2149557.7545 | 0 | 2963523 | 97969 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( SECOND FLOOR) For RCC STAIRCASE
---- etc., complete with all lead | Cum | 13836.87 | 13836.87 | 15.54 | False | None | None | False | None | False | 215024.9598 | 0 | 2963524 | 97969 | None | 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ( SECOND FLOOR) For LINTELS
---- etc., complete with all lead | Cum | 14759.33 | 14759.33 | 6.46 | False | None | None | False | None | False | 95345.2718 | 0 | 2963525 | 97969 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for cills ( SECOND FLOOR)
---- etc., complete with all lead | Cum | 12959.31 | 12959.31 | 8.24 | False | None | None | False | None | False | 106784.7144 | 0 | 2963526 | 97969 | None | 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ( SECOND FLOOR)
---- etc., complete with all lead | Tonne | 120590.9 | 120590.9 | 57.24 | False | None | None | False | None | False | 6902623.116 | 0 | 2963527 | 97969 | None | SR18-19 - 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Rmtr | 38.94 | 38.94 | 184.4 | False | None | None | False | None | False | 7180.536 | 0 | 2963528 | 97969 | None | 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. ( SECOND FLOOR)
---- etc., complete with all lead | Cum | 9105.96 | 9105.96 | 329.23 | False | None | None | False | None | False | 2997955.2108 | 0 | 2963529 | 97969 | None | 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1488.23 | 1488.23 | 181.8 | False | None | None | False | None | False | 270560.214 | 0 | 2963530 | 97969 | None | 12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 4478.16 | 4478.16 | 114.48 | False | None | None | False | None | False | 512659.7568 | 0 | 2963531 | 97969 | None | 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Cum | 133205.78 | 133205.78 | 3.2 | False | None | None | False | None | False | 426258.496 | 0 | 2963532 | 97969 | None | 12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | No | 1369.6 | 1369.6 | 35.0 | False | None | None | False | None | False | 47936.0 | 0 | 2963533 | 97969 | None | 22.15.2 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm ( SECOND FLOOR)
---- etc., complete with all lead | No | 741.42 | 741.42 | 70.0 | False | None | None | False | None | False | 51899.4 | 0 | 2963534 | 97969 | None | 22.15.4 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ( SECOND FLOOR)
---- etc., complete with all lead | No | 505.51 | 505.51 | 35.0 | False | None | None | False | None | False | 17692.85 | 0 | 2963535 | 97969 | None | 22.15.6 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ( SECOND FLOOR)
---- etc., complete with all lead | No | 202.2 | 202.2 | 67.0 | False | None | None | False | None | False | 13547.4 | 0 | 2963536 | 97969 | None | 22.15.9 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ( SECOND FLOOR)
---- etc., complete with all lead | No | 94.36 | 94.36 | 119.0 | False | None | None | False | None | False | 11228.84 | 0 | 2963537 | 97969 | None | 22.15.10 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ( SECOND FLOOR)
---- etc., complete with all lead | No | 134.8 | 134.8 | 35.0 | False | None | None | False | None | False | 4718.0 | 0 | 2963538 | 97969 | None | 12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ( SECOND FLOOR)
---- etc., complete with all lead | No | 1418.13 | 1418.13 | 35.0 | False | None | None | False | None | False | 49634.55 | 0 | 2963539 | 97969 | None | 10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ( SECOND FLOOR)
---- etc., complete with all lead | No | 80.88 | 80.88 | 210.0 | False | None | None | False | None | False | 16984.8 | 0 | 2963540 | 97969 | None | V-2 110 12.90 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 9077.65 | 9077.65 | 89.76 | False | None | None | False | None | False | 814809.864 | 0 | 2963541 | 97969 | None | V-2 109 12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 7709.4 | 7709.4 | 10.8 | False | None | None | False | None | False | 83261.52 | 0 | 2963542 | 97969 | None | V-2 86 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ( SECOND FLOOR)
---- etc., complete with all lead | Kg | 226.47 | 226.47 | 2111.76 | False | None | None | False | None | False | 478250.2872 | 0 | 2963543 | 97969 | None | V-2 111 12.93.1 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ( SECOND FLOOR)
---- etc., complete with all lead | m | 946.32 | 946.32 | 24.0 | False | None | None | False | None | False | 22711.68 | 0 | 2963544 | 97969 | None | V-2 112 12.94.1 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 4697.89 | 4697.89 | 7.56 | False | None | None | False | None | False | 35516.0484 | 0 | 2963545 | 97969 | None | V-2 107 12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1501.71 | 1501.71 | 45.0 | False | None | None | False | None | False | 67576.95 | 0 | 2963546 | 97969 | None | V-2 41 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 420.59 | 420.59 | 3649.5 | False | None | None | False | None | False | 1534943.205 | 0 | 2963547 | 97969 | None | V-2 43 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 284.43 | 284.43 | 1916.17 | False | None | None | False | None | False | 545016.2331 | 0 | 2963548 | 97969 | None | V-2 50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 134.8 | 134.8 | 5565.7 | False | None | None | False | None | False | 750256.36 | 0 | 2963549 | 97969 | None | V-2 42 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 470.46 | 470.46 | 581.94 | False | None | None | False | None | False | 273779.4924 | 0 | 2963550 | 97969 | None | V-2 41 8.3.1 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 477.2 | 477.2 | 87.6 | False | None | None | False | None | False | 41802.72 | 0 | 2963551 | 97969 | None | V-2 43 8.16.2 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ( SECOND FLOOR)
---- etc., complete with all lead | m | 51.23 | 51.23 | 4200.0 | False | None | None | False | None | False | 215166.0 | 0 | 2963552 | 97969 | None | V-2 54 8.79 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ( SECOND FLOOR)
---- etc., complete with all lead | m | 70.1 | 70.1 | 800.8 | False | None | None | False | None | False | 56136.08 | 0 | 2963553 | 97969 | None | V-2 61 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1583.94 | 1583.94 | 1095.07 | False | None | None | False | None | False | 1734525.1758 | 0 | 2963554 | 97969 | None | V-2 62 9.22.2 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1787.49 | 1787.49 | 338.04 | False | None | None | False | None | False | 604243.1196 | 0 | 2963555 | 97969 | None | V-2 64 9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 7182.31 | 7182.31 | 97.02 | False | None | None | False | None | False | 696827.7162 | 0 | 2963556 | 97969 | None | V-2 41 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 397.67 | 397.67 | 443.28 | False | None | None | False | None | False | 176279.1576 | 0 | 2963557 | 97969 | None | V-2 150 15.7 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 829.04 | 829.04 | 50.68 | False | None | None | False | None | False | 42015.7472 | 0 | 2963558 | 97969 | None | V-2 23 7.18 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Cum | 2718.98 | 2718.98 | 10.97 | False | None | None | False | None | False | 29827.2106 | 0 | 2963559 | 97969 | None | V-2 60 9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1198.4 | 1198.4 | 36.58 | False | None | None | False | None | False | 43837.472 | 0 | 2963560 | 97969 | None | V-2 65 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1953.3 | 1953.3 | 105.24 | False | None | None | False | None | False | 205565.292 | 0 | 2963561 | 97969 | None | V-2 85 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ( SECOND FLOOR)
---- etc., complete with all lead | Kg | 761.64 | 761.64 | 352.8 | False | None | None | False | None | False | 268706.592 | 0 | 2963562 | 97969 | None | V-2 48 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 171.2 | 171.2 | 5565.67 | False | None | None | False | None | False | 952842.704 | 0 | 2963563 | 97969 | None | V-2 46 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 210.29 | 210.29 | 581.94 | False | None | None | False | None | False | 122376.1626 | 0 | 2963564 | 97969 | None | V-2 47 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 67.4 | 67.4 | 100.56 | False | None | None | False | None | False | 6777.744 | 0 | 2963565 | 97969 | None | V-2 48 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 155.02 | 155.02 | 100.56 | False | None | None | False | None | False | 15588.8112 | 0 | 2963566 | 97969 | None | V-2 47 8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 71.45 | 71.45 | 274.75 | False | None | None | False | None | False | 19630.8875 | 0 | 2963567 | 97969 | None | V-2 54 8.82 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 912.62 | 912.62 | 274.75 | False | None | None | False | None | False | 250742.345 | 0 | 2963568 | 97969 | None | V-2 183 18.3 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6.12. 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, 12mm Airgap 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 4102.06 | 4102.06 | 150.0 | False | None | None | False | None | False | 615309.0 | 0 | 2963569 | 97969 | None | V-2 183 18.4 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 5605.12 | 5605.12 | 60.0 | False | None | None | False | None | False | 336307.2 | 0 | 2963570 | 97969 | None | V-2 25 7.31 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 1717.39 | 1717.39 | 126.5 | False | None | None | False | None | False | 217249.835 | 0 | 2963571 | 97969 | None | V-2 28 7.41 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 2282.22 | 2282.22 | 189.7 | False | None | None | False | None | False | 432937.134 | 0 | 2963572 | 97969 | None | V-2 69 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ( SECOND FLOOR)
---- etc., complete with all lead | Sqm | 5400.22 | 5400.22 | 63.25 | False | None | None | False | None | False | 341563.915 | 0 | 2963573 | 97969 | None | Approved data rate | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ( SECOND FLOOR)
---- etc., complete with all lead | m | 2596.0 | 2596.0 | 290.0 | False | None | None | False | None | False | 752840.0 | 0 | 2963574 | 97969 | None | V-2 181 18.1 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ( SECOND FLOOR)
---- etc., complete with all lead | Kg | 548.65 | 548.65 | 1316.25 | False | None | None | False | None | False | 722160.5625 | 0 | 2963575 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for columns(Terrace)
---- etc., complete with all lead | Cum | 15835.53 | 15835.53 | 20.84 | False | None | None | False | None | False | 330012.4452 | 0 | 2963576 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for RCC Beams and Lintels(Terrace)
---- etc., complete with all lead | Cum | 14904.03 | 14904.03 | 29.73 | False | None | None | False | None | False | 443096.8119 | 0 | 2963577 | 97969 | None | V-1 16 2.5.2 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for RCC roof slab (Terrace)
---- etc., complete with all lead | Cum | 13972.53 | 13972.53 | 30.79 | False | None | None | False | None | False | 430214.1987 | 0 | 2963578 | 97969 | None | V-1 16 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork for cills (Terrace)
---- etc., complete with all lead | Cum | 13086.36 | 13086.36 | 1.09 | False | None | None | False | None | False | 14264.1324 | 0 | 2963579 | 97969 | None | V-1 18 2.11 a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Terrace)
---- etc., complete with all lead | Tonne | 121773.16 | 121773.16 | 9.94 | False | None | None | False | None | False | 1210425.2104 | 0 | 2963580 | 97969 | None | 18-19 SR 15 4.21 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. (Terrace)
---- etc., complete with all lead | m | 38.94 | 38.94 | 9.9 | False | None | None | False | None | False | 385.506 | 0 | 2963581 | 97969 | None | V-2 9 5.7 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (Terrace)
---- etc., complete with all lead | Cum | 9195.23 | 9195.23 | 96.32 | False | None | None | False | None | False | 885684.5536 | 0 | 2963582 | 97969 | None | V-2 110 12.90 | Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL.9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm .2.5mm. Maximum possible size . 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (Terrace)
---- etc., complete with all lead | Sqm | 9166.64 | 9166.64 | 17.7 | False | None | None | False | None | False | 162249.528 | 0 | 2963583 | 97969 | None | V-2 86 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (Terrace)
---- etc., complete with all lead | Kg | 228.69 | 228.69 | 371.7 | False | None | None | False | None | False | 85004.073 | 0 | 2963584 | 97969 | None | V-2 77 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. (Terrace)
---- etc., complete with all lead | Sqm | 6095.67 | 6095.67 | 6.3 | False | None | None | False | None | False | 38402.721 | 0 | 2963585 | 97969 | None | V-2 41 8.4.2 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Inside) (Terrace)
---- etc., complete with all lead | Sqm | 424.71 | 424.71 | 233.36 | False | None | None | False | None | False | 99110.3256 | 0 | 2963586 | 97969 | None | V-2 43 8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Terrace)
---- etc., complete with all lead | Sqm | 287.22 | 287.22 | 407.15 | False | None | None | False | None | False | 116941.623 | 0 | 2963587 | 97969 | None | V-2 50 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Terrace)
---- etc., complete with all lead | Sqm | 136.12 | 136.12 | 640.5 | False | None | None | False | None | False | 87184.86 | 0 | 2963588 | 97969 | None | V-2 42 8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ( Outside) (Terrace)
---- etc., complete with all lead | Sqm | 475.08 | 475.08 | 657.2 | False | None | None | False | None | False | 312222.576 | 0 | 2963589 | 97969 | None | V-2 152 15.13 | Newly Constructed Roof/Podium with PU Waterproof coating Above 500 m2 Providing and Applying single component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.4kg/m2 in 3 coats to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids greater than 85%, Tensile strength greater than 2 Mpa as per ASTM D 412, Elongation at break greater than 400% confirms to ASTM C 1305 for crack bridging ability (no cracks up to 3.2mm) Shore A Hardness greaterthan 55 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration as per UNE CN/ TS 14416. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification.
---- etc., complete with all lead | Sqm | 1585.85 | 1585.85 | 1300.0 | False | None | None | False | None | False | 2061605.0 | 0 | 2963590 | 97969 | None | V-2 48 8.39 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( TERRACE FLOOR)
---- etc., complete with all lead | Sqm | 172.88 | 172.88 | 640.51 | False | None | None | False | None | False | 110731.3688 | 0 | 2963591 | 97969 | None | V-2 46 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( TERRACE FLOOR)
---- etc., complete with all lead | Sqm | 212.35 | 212.35 | 657.2 | False | None | None | False | None | False | 139556.42 | 0 | 2963592 | 97969 | None | V-2 47 8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( TERRACE FLOOR)
---- etc., complete with all lead | Sqm | 68.06 | 68.06 | 24.0 | False | None | None | False | None | False | 1633.44 | 0 | 2963593 | 97969 | None | V-2 48 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Terrace)
---- etc., complete with all lead | Sqm | 156.54 | 156.54 | 24.0 | False | None | None | False | None | False | 3756.96 | 0 | 2963594 | 97969 | None | V-5 113 10.1.7 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (Terrace)
---- etc., complete with all lead | m | 559.47 | 559.47 | 90.0 | False | None | None | False | None | False | 50352.3 | 0 | 2963595 | 97969 | None | V-5 85 7.1.2 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete withwith:: MS angle of 65 x 65 x 10mm (Terrace)
---- etc., complete with all lead | m | 6535.35 | 6535.35 | 13.2 | False | None | None | False | None | False | 86266.62 | 0 | 2963596 | 97969 | None | Approved rate | The Tenderer (agency) should arrange to obtain (get), detailed Architectural drawings and elevations, Structural designs and drawings including Soil exploration & proof checking by IISC /IIT/NIT only as decided by the Department and the same has to be furnished to the Department for approval and providing consultancy for Architectural designs & drawings, elevation, 3D view, MFP design and Drawings, Internal and External Electrical services including electrical infrastructure , interior layout and liaison with other department and approval of pollution control board and allied works etc., and any other drawings related to this project (This item is included in schedule B as a item) and 6 sets of as built drawings should be submitted to the employer. The Consultancy Fees which is included as an item in schedule B shall be paid on prorate basis of the main work or by negotiation with the employer. - etc., complete with all lead & lift and work to be executed as per the specification and Engineer-in-charge of the work.
---- etc., complete with all lead | Job | 2232520.0 | 2232520.0 | 1.0 | False | None | None | False | None | False | 2232520.0 | 0 |
| 1709811496000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK HOSPITAL AT MANGALURU, KARNATAKA-ELECTRICAL WORKS | 39804972.94 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2963597 | 97970 | None | V-6 5 2.2.1 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch
---- etc., complete with all lead | Point | 355.51 | 355.51 | 105.0 | False | None | None | False | None | False | 37328.55 | 0 | 2963598 | 97970 | None | V-6 5 2.2.2 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
---- etc., complete with all lead | Point | 500.89 | 500.89 | 200.0 | False | None | None | False | None | False | 100178.0 | 0 | 2963599 | 97970 | None | V-6 5 2.2.3 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch
---- etc., complete with all lead | Point | 733.49 | 733.49 | 350.0 | False | None | None | False | None | False | 256721.5 | 0 | 2963600 | 97970 | None | V-6 5 2.2.4 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches
---- etc., complete with all lead | Point | 894.72 | 894.72 | 65.0 | False | None | None | False | None | False | 58156.8 | 0 | 2963601 | 97970 | None | V-6 5 2.2.5 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches
---- etc., complete with all lead | Point | 1307.06 | 1307.06 | 30.0 | False | None | None | False | None | False | 39211.8 | 0 | 2963602 | 97970 | None | V-6 8 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way
---- etc., complete with all lead | Each | 182.38 | 182.38 | 185.0 | False | None | None | False | None | False | 33740.3 | 0 | 2963603 | 97970 | None | V-6 8 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way
---- etc., complete with all lead | Each | 210.13 | 210.13 | 330.0 | False | None | None | False | None | False | 69342.9 | 0 | 2963604 | 97970 | None | V-6 8 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way
---- etc., complete with all lead | Each | 233.92 | 233.92 | 140.0 | False | None | None | False | None | False | 32748.8 | 0 | 2963605 | 97970 | None | V-6 8 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way
---- etc., complete with all lead | Each | 290.75 | 290.75 | 90.0 | False | None | None | False | None | False | 26167.5 | 0 | 2963606 | 97970 | None | V-6 8 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way
---- etc., complete with all lead | Each | 344.94 | 344.94 | 135.0 | False | None | None | False | None | False | 46566.9 | 0 | 2963607 | 97970 | None | V-6 8 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way
---- etc., complete with all lead | Each | 421.59 | 421.59 | 220.0 | False | None | None | False | None | False | 92749.8 | 0 | 2963608 | 97970 | None | V-6 8 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module
---- etc., complete with all lead | Each | 181.06 | 181.06 | 185.0 | False | None | None | False | None | False | 33496.1 | 0 | 2963609 | 97970 | None | V-6 8 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module
---- etc., complete with all lead | Each | 212.78 | 212.78 | 330.0 | False | None | None | False | None | False | 70217.4 | 0 | 2963610 | 97970 | None | V-6 8 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module
---- etc., complete with all lead | Each | 231.28 | 231.28 | 140.0 | False | None | None | False | None | False | 32379.2 | 0 | 2963611 | 97970 | None | V-6 8 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module
---- etc., complete with all lead | Each | 309.25 | 309.25 | 90.0 | False | None | None | False | None | False | 27832.5 | 0 | 2963612 | 97970 | None | V-6 8 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module
---- etc., complete with all lead | Each | 375.33 | 375.33 | 135.0 | False | None | None | False | None | False | 50669.55 | 0 | 2963613 | 97970 | None | V-6 8 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module
---- etc., complete with all lead | Each | 454.63 | 454.63 | 220.0 | False | None | None | False | None | False | 100018.6 | 0 | 2963614 | 97970 | None | V-6 9 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch
---- etc., complete with all lead | Each | 134.8 | 134.8 | 1030.0 | False | None | None | False | None | False | 138844.0 | 0 | 2963615 | 97970 | None | V-6 9 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch
---- etc., complete with all lead | Each | 219.39 | 219.39 | 18.0 | False | None | None | False | None | False | 3949.02 | 0 | 2963616 | 97970 | None | V-6 9 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket
---- etc., complete with all lead | Each | 225.99 | 225.99 | 280.0 | False | None | None | False | None | False | 63277.2 | 0 | 2963617 | 97970 | None | V-6 9 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.
---- etc., complete with all lead | Each | 471.81 | 471.81 | 40.0 | False | None | None | False | None | False | 18872.4 | 0 | 2963618 | 97970 | None | V-6 9 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch
---- etc., complete with all lead | Each | 430.84 | 430.84 | 50.0 | False | None | None | False | None | False | 21542.0 | 0 | 2963619 | 97970 | None | V-6 9 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket
---- etc., complete with all lead | Each | 311.9 | 311.9 | 80.0 | False | None | None | False | None | False | 24952.0 | 0 | 2963620 | 97970 | None | V-6 9 3.6.7 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch
---- etc., complete with all lead | Each | 237.89 | 237.89 | 30.0 | False | None | None | False | None | False | 7136.7 | 0 | 2963621 | 97970 | None | V-6 4 1.13 | Supplyin and Fixing Metal Fan Box with Round Hook.
---- etc., complete with all lead | Nos | 154.63 | 154.63 | 40.0 | False | None | None | False | None | False | 6185.2 | 0 | 2963622 | 97970 | None | V-6 21 5.45.2 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20Amps
---- etc., complete with all lead | Each | 1283.27 | 1283.27 | 4.0 | False | None | None | False | None | False | 5133.08 | 0 | 2963623 | 97970 | None | V-6 21 5.45.4 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30Amps
---- etc., complete with all lead | Each | 2246.72 | 2246.72 | 4.0 | False | None | None | False | None | False | 8986.88 | 0 | 2963624 | 97970 | None | V-6 2 1.2.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick
---- etc., complete with all lead | m | 87.23 | 87.23 | 4500.0 | False | None | None | False | None | False | 392535.0 | 0 | 2963625 | 97970 | None | V-6 2 1.2.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick
---- etc., complete with all lead | m | 103.08 | 103.08 | 16900.0 | False | None | None | False | None | False | 1742052.0 | 0 | 2963626 | 97970 | None | V-6 2 1.2.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick
---- etc., complete with all lead | m | 136.12 | 136.12 | 1800.0 | False | None | None | False | None | False | 245016.0 | 0 | 2963627 | 97970 | None | V-6 2 1.3.1 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick
---- etc., complete with all lead | m | 89.87 | 89.87 | 2200.0 | False | None | None | False | None | False | 197714.0 | 0 | 2963628 | 97970 | None | V-6 2 1.3.2 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick
---- etc., complete with all lead | m | 104.41 | 104.41 | 4000.0 | False | None | None | False | None | False | 417640.0 | 0 | 2963629 | 97970 | None | V-6 2 1.3.3 | Supplying heavy gauge PVC conduit pipe …….dia . mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick
---- etc., complete with all lead | m | 130.84 | 130.84 | 1000.0 | False | None | None | False | None | False | 130840.0 | 0 | 2963630 | 97970 | None | V-6 5 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm
---- etc., complete with all lead | m | 34.36 | 34.36 | 4000.0 | False | None | None | False | None | False | 137440.0 | 0 | 2963631 | 97970 | None | V-6 5 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm
---- etc., complete with all lead | m | 55.51 | 55.51 | 13000.0 | False | None | None | False | None | False | 721630.0 | 0 | 2963632 | 97970 | None | V-6 5 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm
---- etc., complete with all lead | m | 83.26 | 83.26 | 8000.0 | False | None | None | False | None | False | 666080.0 | 0 | 2963633 | 97970 | None | V-6 5 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm ---- etc., complete with all lead | m | 121.59 | 121.59 | 3800.0 | False | None | None | False | None | False | 462042.0 | 0 | 2963634 | 97970 | None | V-6 5 2.3.6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 10 sqmm
---- etc., complete with all lead | m | 220.71 | 220.71 | 1000.0 | False | None | None | False | None | False | 220710.0 | 0 | 2963635 | 97970 | None | V-6 18 5.19.11 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N
---- etc., complete with all lead | Each | 5336.62 | 5336.62 | 11.0 | False | None | None | False | None | False | 58702.82 | 0 | 2963636 | 97970 | None | V-6 18 5.19.12 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N
---- etc., complete with all lead | Each | 6528.7 | 6528.7 | 11.0 | False | None | None | False | None | False | 71815.7 | 0 | 2963637 | 97970 | None | V-6 18 5.19.9 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N
---- etc., complete with all lead | Each | 3078.01 | 3078.01 | 4.0 | False | None | None | False | None | False | 12312.04 | 0 | 2963638 | 97970 | None | V-6 17 5.18.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP
---- etc., complete with all lead | Each | 548.46 | 548.46 | 438.0 | False | None | None | False | None | False | 240225.48 | 0 | 2963639 | 97970 | None | V-6 17 5.18.8 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN
---- etc., complete with all lead | Each | 4022.95 | 4022.95 | 25.0 | False | None | None | False | None | False | 100573.75 | 0 | 2963640 | 97970 | None | V-6 18 5.18.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN
---- etc., complete with all lead | Each | 4081.1 | 4081.1 | 78.0 | False | None | None | False | None | False | 318325.8 | 0 | 2963641 | 97970 | None | V-6 18 5.20.8 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole
---- etc., complete with all lead | Each | 6802.28 | 6802.28 | 22.0 | False | None | None | False | None | False | 149650.16 | 0 | 2963642 | 97970 | None | V-6 18 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 pole
---- etc., complete with all lead | Each | 5652.48 | 5652.48 | 4.0 | False | None | None | False | None | False | 22609.92 | 0 | 2963643 | 97970 | None | V-6 13 32.05 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm
---- etc., complete with all lead | Km | 116853.23 | 116853.23 | 0.9 | False | None | None | False | None | False | 105167.907 | 0 | 2963644 | 97970 | None | V-6 13 32.07 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm
---- etc., complete with all lead | Km | 184427.96 | 184427.96 | 0.8 | False | None | None | False | None | False | 147542.368 | 0 | 2963645 | 97970 | None | V-6 13 32.09 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm
---- etc., complete with all lead | Km | 203608.34 | 203608.34 | 0.35 | False | None | None | False | None | False | 71262.919 | 0 | 2963646 | 97970 | None | V-6 13 32.11 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 50 sqmm
---- etc., complete with all lead | Km | 236530.72 | 236530.72 | 0.4 | False | None | None | False | None | False | 94612.288 | 0 | 2963647 | 97970 | None | V-6 13 32.13 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm
---- etc., complete with all lead | Km | 420152.5 | 420152.5 | 0.5 | False | None | None | False | None | False | 210076.25 | 0 | 2963648 | 97970 | None | V-6 13 32.14 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm
---- etc., complete with all lead | Km | 493240.94 | 493240.94 | 0.25 | False | None | None | False | None | False | 123310.235 | 0 | 2963649 | 97970 | None | V-6 13 32.15 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 120 sqmm
---- etc., complete with all lead | Km | 603824.5 | 603824.5 | 0.1 | False | None | None | False | None | False | 60382.45 | 0 | 2963650 | 97970 | None | V-6 13 32.17 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 185 sqmm
---- etc., complete with all lead | Km | 913513.71 | 913513.71 | 0.05 | False | None | None | False | None | False | 45675.6855 | 0 | 2963651 | 97970 | None | V-6 13 32.18 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 240 sqmm
---- etc., complete with all lead | Km | 1140099.39 | 1140099.39 | 0.1 | False | None | None | False | None | False | 114009.939 | 0 | 2963652 | 97970 | None | V-6 13 32.19 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 300 sqmm
---- etc., complete with all lead | Km | 1408844.1 | 1408844.1 | 0.6 | False | None | None | False | None | False | 845306.46 | 0 | 2963653 | 97970 | None | V-6 52 31.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm
---- etc., complete with all lead | Km | 27602.94 | 27602.94 | 1.7 | False | None | None | False | None | False | 46924.998 | 0 | 2963654 | 97970 | None | V-6 52 31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm
---- etc., complete with all lead | Km | 41153.3 | 41153.3 | 1.5 | False | None | None | False | None | False | 61729.95 | 0 | 2963655 | 97970 | None | V-6 52 31.07 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 sqmm to 300 sqmm
---- etc., complete with all lead | Km | 42658.6 | 42658.6 | 0.85 | False | None | None | False | None | False | 36259.81 | 0 | 2963656 | 97970 | None | PWD SR 19-20 6.11.3 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia
---- etc., complete with all lead | Each | 154.63 | 154.63 | 25.0 | False | None | None | False | None | False | 3865.75 | 0 | 2963657 | 97970 | None | PWD SR 19-20 6.11.6 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia
---- etc., complete with all lead | Each | 512.78 | 512.78 | 28.0 | False | None | None | False | None | False | 14357.84 | 0 | 2963658 | 97970 | None | PWD SR 19-20 6.17.6 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm
---- etc., complete with all lead | Each | 16.44 | 16.44 | 24.0 | False | None | None | False | None | False | 394.56 | 0 | 2963659 | 97970 | None | PWD SR 19-20 6.17.8 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel
---- etc., complete with all lead | Each | 42.29 | 42.29 | 32.0 | False | None | None | False | None | False | 1353.28 | 0 | 2963660 | 97970 | None | PWD SR 19-20 6.17.9 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel
---- etc., complete with all lead | Each | 79.3 | 79.3 | 24.0 | False | None | None | False | None | False | 1903.2 | 0 | 2963661 | 97970 | None | PWD SR 19-20 6.17.10 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel
---- etc., complete with all lead | Each | 158.59 | 158.59 | 32.0 | False | None | None | False | None | False | 5074.88 | 0 | 2963662 | 97970 | None | PWD SR 19-20 6.17.11 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 95 sqmm Long Barrel
---- etc., complete with all lead | Each | 198.24 | 198.24 | 24.0 | False | None | None | False | None | False | 4757.76 | 0 | 2963663 | 97970 | None | PWD SR 19-20 6.17.12 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 120 sqmm Long Barrel
---- etc., complete with all lead | Each | 251.1 | 251.1 | 24.0 | False | None | None | False | None | False | 6026.4 | 0 | 2963664 | 97970 | None | PWD SR 19-20 6.17.14 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm Long Barrel
---- etc., complete with all lead | Each | 432.16 | 432.16 | 16.0 | False | None | None | False | None | False | 6914.56 | 0 | 2963665 | 97970 | None | PWD SR 19-20 6.17.15 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 240 sqmm Long Barrel
---- etc., complete with all lead | Each | 611.9 | 611.9 | 16.0 | False | None | None | False | None | False | 9790.4 | 0 | 2963666 | 97970 | None | PWD SR 19-20 6.17.16 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 300 sqmm Long Barrel
---- etc., complete with all lead | Each | 828.64 | 828.64 | 16.0 | False | None | None | False | None | False | 13258.24 | 0 | 2963667 | 97970 | None | V-6 54 12.56 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia
---- etc., complete with all lead | Nos | 4638.82 | 4638.82 | 32.0 | False | None | None | False | None | False | 148442.24 | 0 | 2963668 | 97970 | None | V-6 54 12.58.2 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip
---- etc., complete with all lead | m | 108.37 | 108.37 | 730.0 | False | None | None | False | None | False | 79110.1 | 0 | 2963669 | 97970 | None | V-6 55 12.58.7 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 25x6mm Copper strip
---- etc., complete with all lead | m | 753.31 | 753.31 | 200.0 | False | None | None | False | None | False | 150662.0 | 0 | 2963670 | 97970 | None | V-6 55 12.58.11 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate
---- etc., complete with all lead | Each | 9807.59 | 9807.59 | 32.0 | False | None | None | False | None | False | 313842.88 | 0 | 2963671 | 97970 | None | V-6 44 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220. 240V @ 50/60Hz & Power factor greaterthan 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10.12W
---- etc., complete with all lead | Each | 1169.62 | 1169.62 | 90.0 | False | None | None | False | None | False | 105265.8 | 0 | 2963672 | 97970 | None | V-6 44 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 18W
---- etc., complete with all lead | Each | 1749.8 | 1749.8 | 170.0 | False | None | None | False | None | False | 297466.0 | 0 | 2963673 | 97970 | None | V-6 43 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w
---- etc., complete with all lead | Each | 911.9 | 911.9 | 290.0 | False | None | None | False | None | False | 264451.0 | 0 | 2963674 | 97970 | None | V-6 47 11.11.3 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K
---- etc., complete with all lead | Each | 196.92 | 196.92 | 35.0 | False | None | None | False | None | False | 6892.2 | 0 | 2963675 | 97970 | None | V-6 47 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K
---- etc., complete with all lead | Each | 355.51 | 355.51 | 70.0 | False | None | None | False | None | False | 24885.7 | 0 | 2963676 | 97970 | None | V-6 45 11.6.3 | Supplying of recess mounting non integral type .LED . W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt
---- etc., complete with all lead | Each | 6017.24 | 6017.24 | 135.0 | False | None | None | False | None | False | 812327.4 | 0 | 2963677 | 97970 | None | V-6 46 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 40watts
---- etc., complete with all lead | No | 5318.12 | 5318.12 | 13.0 | False | None | None | False | None | False | 69135.56 | 0 | 2963678 | 97970 | None | V-6 30 6.1 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.
---- etc., complete with all lead | Each | 1971.83 | 1971.83 | 35.0 | False | None | None | False | None | False | 69014.05 | 0 | 2963679 | 97970 | None | V-6 30 6.2.2 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450mm)
---- etc., complete with all lead | Each | 5452.92 | 5452.92 | 5.0 | False | None | None | False | None | False | 27264.6 | 0 | 2963680 | 97970 | None | V-6 30 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm)
---- etc., complete with all lead | Each | 3537.92 | 3537.92 | 40.0 | False | None | None | False | None | False | 141516.8 | 0 | 2963681 | 97970 | None | V-6 30 6.5.1 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep
---- etc., complete with all lead | Each | 3293.43 | 3293.43 | 10.0 | False | None | None | False | None | False | 32934.3 | 0 | 2963682 | 97970 | None | V-6 52 12.46 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin
---- etc., complete with all lead | Each | 83.26 | 83.26 | 105.0 | False | None | None | False | None | False | 8742.3 | 0 | 2963683 | 97970 | None | V-6 56 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
---- etc., complete with all lead | Each | 161.24 | 161.24 | 685.0 | False | None | None | False | None | False | 110449.4 | 0 | 2963684 | 97970 | None | V-6 57 13.11 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired
---- etc., complete with all lead | Each | 416.3 | 416.3 | 50.0 | False | None | None | False | None | False | 20815.0 | 0 | 2963685 | 97970 | None | V-6 57 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
---- etc., complete with all lead | Each | 934.37 | 934.37 | 40.0 | False | None | None | False | None | False | 37374.8 | 0 | 2963686 | 97970 | None | V-6 56 13.4.1 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. Length
---- etc., complete with all lead | Each | 1930.86 | 1930.86 | 33.0 | False | None | None | False | None | False | 63718.38 | 0 | 2963687 | 97970 | None | V-6 56 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.
---- etc., complete with all lead | Each | 214.1 | 214.1 | 33.0 | False | None | None | False | None | False | 7065.3 | 0 | 2963688 | 97970 | None | V-6 20 5.42.1 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG
---- etc., complete with all lead | Sq CM | 0.66 | 0.66 | 2426000.0 | False | None | None | False | None | False | 1601160.0 | 0 | 2963689 | 97970 | None | V-6 20 5.40.5 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips
---- etc., complete with all lead | Mtr | 13982.53 | 13982.53 | 25.0 | False | None | None | False | None | False | 349563.25 | 0 | 2963690 | 97970 | None | V-6 20 5.41.3 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm
---- etc., complete with all lead | Mtr | 733.49 | 733.49 | 42.0 | False | None | None | False | None | False | 30806.58 | 0 | 2963691 | 97970 | None | V-6 20 5.41.5 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel
---- etc., complete with all lead | Mtr | 1223.8 | 1223.8 | 42.0 | False | None | None | False | None | False | 51399.6 | 0 | 2963692 | 97970 | None | V-6 17 5.15.9 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA
---- etc., complete with all lead | Each | 11216.42 | 11216.42 | 44.0 | False | None | None | False | None | False | 493522.48 | 0 | 2963693 | 97970 | None | V-6 17 5.15.10 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA125Amps 25kA
---- etc., complete with all lead | Each | 13666.67 | 13666.67 | 7.0 | False | None | None | False | None | False | 95666.69 | 0 | 2963694 | 97970 | None | V-6 17 5.15.11 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 160Amps 25kA
---- etc., complete with all lead | Each | 17771.56 | 17771.56 | 7.0 | False | None | None | False | None | False | 124400.92 | 0 | 2963695 | 97970 | None | V-6 17 5.15.13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 250Amps 35kA
---- etc., complete with all lead | Each | 28270.35 | 28270.35 | 6.0 | False | None | None | False | None | False | 169622.1 | 0 | 2963696 | 97970 | None | V-6 17 5.15.17 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA
---- etc., complete with all lead | Each | 39794.7 | 39794.7 | 2.0 | False | None | None | False | None | False | 79589.4 | 0 | 2963697 | 97970 | None | V-6 22 5.51.4 | Supply and fixing of fully Enclosed 250A Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts
---- etc., complete with all lead | Each | 138556.54 | 138556.54 | 1.0 | False | None | None | False | None | False | 138556.54 | 0 | 2963698 | 97970 | None | V-6 18 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board
---- etc., complete with all lead | Each | 12231.41 | 12231.41 | 2.0 | False | None | None | False | None | False | 24462.82 | 0 | 2963699 | 97970 | None | V-6 19 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy
---- etc., complete with all lead | Each | 12310.7 | 12310.7 | 18.0 | False | None | None | False | None | False | 221592.6 | 0 | 2963700 | 97970 | None | V-6 19 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C
---- etc., complete with all lead | Each | 680.62 | 680.62 | 63.0 | False | None | None | False | None | False | 42879.06 | 0 | 2963701 | 97970 | None | V-6 19 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound
---- etc., complete with all lead | Each | 742.74 | 742.74 | 51.0 | False | None | None | False | None | False | 37879.74 | 0 | 2963702 | 97970 | None | V-6 17 5.16 | Suppiying and fixing of Shunt trip suitable for MCCB.CBCT
---- etc., complete with all lead | Each | 2250.68 | 2250.68 | 2.0 | False | None | None | False | None | False | 4501.36 | 0 | 2963703 | 97970 | None | V-6 19 5.36 | Supplying,fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer
---- etc., complete with all lead | Each | 1110.14 | 1110.14 | 9.0 | False | None | None | False | None | False | 9991.26 | 0 | 2963704 | 97970 | None | V-6 20 5.42.2 | Fabricating supplying and mounting MS box made out .SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG
---- etc., complete with all lead | Sq CM | 0.57 | 0.57 | 4142000.0 | False | None | None | False | None | False | 2360940.0 | 0 | 2963705 | 97970 | None | V-6 20 5.40.3 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Aluminum Strips
---- etc., complete with all lead | m | 5874.51 | 5874.51 | 15.0 | False | None | None | False | None | False | 88117.65 | 0 | 2963706 | 97970 | None | V-6 20 5.41.2 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm
---- etc., complete with all lead | m | 522.03 | 522.03 | 30.0 | False | None | None | False | None | False | 15660.9 | 0 | 2963707 | 97970 | None | V-6 20 5.41.4 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete with all lead | m | 999.13 | 999.13 | 214.0 | False | None | None | False | None | False | 213813.82 | 0 | 2963708 | 97970 | None | V-6 19 5.39 | Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs.
---- etc., complete with all lead | Each | 28599.42 | 28599.42 | 1.0 | False | None | None | False | None | False | 28599.42 | 0 | 2963709 | 97970 | None | V-6 19 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery
---- etc., complete with all lead | Kvar | 634.37 | 634.37 | 150.0 | False | None | None | False | None | False | 95155.5 | 0 | 2963710 | 97970 | None | V-6 15 5.13.1 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps
---- etc., complete with all lead | Each | 1704.86 | 1704.86 | 5.0 | False | None | None | False | None | False | 8524.3 | 0 | 2963711 | 97970 | None | V-6 15 5.13.2 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps
---- etc., complete with all lead | Each | 2984.17 | 2984.17 | 5.0 | False | None | None | False | None | False | 14920.85 | 0 | 2963712 | 97970 | None | V-6 20 5.40.1 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips
---- etc., complete with all lead | m | 3257.74 | 3257.74 | 38.0 | False | None | None | False | None | False | 123794.12 | 0 | 2963713 | 97970 | None | V-6 20 5.40.2 | Supplying .amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips
---- etc., complete with all lead | m | 4539.7 | 4539.7 | 62.0 | False | None | None | False | None | False | 281461.4 | 0 | 2963714 | 97970 | None | V-6 20 5.41.1 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm
---- etc., complete with all lead | m | 403.09 | 403.09 | 204.0 | False | None | None | False | None | False | 82230.36 | 0 | 2963715 | 97970 | None | V-6 17 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP
---- etc., complete with all lead | Each | 976.66 | 976.66 | 26.0 | False | None | None | False | None | False | 25393.16 | 0 | 2963716 | 97970 | None | V-6 17 5.18.7 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN
---- etc., complete with all lead | Each | 2269.19 | 2269.19 | 28.0 | False | None | None | False | None | False | 63537.32 | 0 | 2963717 | 97970 | None | V-6 14 5.2.1 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired ajter fixing to the existing wooden board for motor Upto 12.5 HP
---- etc., complete with all lead | Each | 9852.53 | 9852.53 | 24.0 | False | None | None | False | None | False | 236460.72 | 0 | 2963718 | 97970 | None | V-6 20 5.41.6 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron. and M.S. flat . with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel
---- etc., complete with all lead | m | 999.13 | 999.13 | 20.0 | False | None | None | False | None | False | 19982.6 | 0 | 2963719 | 97970 | None | V-6 11 4.1.1 | Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32
---- etc., complete with all lead | Each | 20484.8 | 20484.8 | 20.0 | False | None | None | False | None | False | 409696.0 | 0 | 2963720 | 97970 | None | V-6 46 11.8.3 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts
---- etc., complete with all lead | Each | 7919.03 | 7919.03 | 20.0 | False | None | None | False | None | False | 158380.6 | 0 | 2963721 | 97970 | None | V-6 47 11.12.2 | Supply of LED Bollard light fitting of .W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr Height
---- etc., complete with all lead | Each | 5985.46 | 5985.46 | 10.0 | False | None | None | False | None | False | 59854.6 | 0 | 2963722 | 97970 | None | V-6 59 14.4.6 | Design, supplying, erecting testing and commissioning of - 20Passenger/ Bed-cum-passenger hospital lift(4 stops/4 Opening) with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka.
---- etc., complete with all lead | Each | 3973787.91 | 3973787.91 | 2.0 | False | None | None | False | None | False | 7947575.82 | 0 | 2963723 | 97970 | None | V-6 9 3.6.13 | RJ45/ I.O. outlet Cat 6
---- etc., complete with all lead | Each | 445.38 | 445.38 | 50.0 | False | None | None | False | None | False | 22269.0 | 0 | 2963724 | 97970 | None | V-6 9 3.6.12 | Telephone socket
---- etc., complete with all lead | Each | 206.17 | 206.17 | 35.0 | False | None | None | False | None | False | 7215.95 | 0 | 2963725 | 97970 | None | V-6 36 8.1 | Supplying and drawing UTP-CAT 6E LAN cable.
---- etc., complete with all lead | m | 50.22 | 50.22 | 10300.0 | False | None | None | False | None | False | 517266.0 | 0 | 2963726 | 97970 | None | V-6 36 8.10.1 | Supplying & Fixing of I/O Socket with back box Single I/O
---- etc., complete with all lead | Each | 647.58 | 647.58 | 50.0 | False | None | None | False | None | False | 32379.0 | 0 | 2963727 | 97970 | None | V-6 36 8.4.3 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth
---- etc., complete with all lead | Each | 11201.88 | 11201.88 | 8.0 | False | None | None | False | None | False | 89615.04 | 0 | 2963728 | 97970 | None | V-6 36 8.9.11 | Supplying fixing of Network Switches. 16 port 10/100/1000 Switch
---- etc., complete with all lead | Each | 8511.1 | 8511.1 | 4.0 | False | None | None | False | None | False | 34044.4 | 0 | 2963729 | 97970 | None | V-6 37 8.11.1 | Supplying & fixing of .mtrs. Cat 6Patch Cable. 2Mtr
---- etc., complete with all lead | Each | 339.65 | 339.65 | 50.0 | False | None | None | False | None | False | 16982.5 | 0 | 2963730 | 97970 | None | V-6 37 8.12.3 | Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel
---- etc., complete with all lead | Each | 4030.88 | 4030.88 | 4.0 | False | None | None | False | None | False | 16123.52 | 0 | 2963731 | 97970 | None | V-6 36 8.2.2 | Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable.
---- etc., complete with all lead | Mtr | 27.75 | 27.75 | 1800.0 | False | None | None | False | None | False | 49950.0 | 0 | 2963732 | 97970 | None | V-6 37 8.13.2 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair
---- etc., complete with all lead | Each | 506.17 | 506.17 | 3.0 | False | None | None | False | None | False | 1518.51 | 0 | 2963733 | 97970 | None | V-6 37 8.12.2 | Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel
---- etc., complete with all lead | Each | 5418.56 | 5418.56 | 6.0 | False | None | None | False | None | False | 32511.36 | 0 | 2963734 | 97970 | None | V-6 9 3.6.11 | TV socket
---- etc., complete with all lead | Each | 206.17 | 206.17 | 10.0 | False | None | None | False | None | False | 2061.7 | 0 | 2963735 | 97970 | None | V-6 36 8.3 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.
---- etc., complete with all lead | Rmtr | 58.15 | 58.15 | 600.0 | False | None | None | False | None | False | 34890.0 | 0 | 2963736 | 97970 | None | V-6 3 1.01 | DP STRUCTURE
Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete with all lead | Set | 9351.64 | 9351.64 | 2.0 | False | None | None | False | None | False | 18703.28 | 0 | 2963737 | 97970 | None | V-6 44 2.02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785
---- etc., complete with all lead | Set | 1470.94 | 1470.94 | 2.0 | False | None | None | False | None | False | 2941.88 | 0 | 2963738 | 97970 | None | V-6 5 6.05 | Supply of 11 kV, 45 KN Polymeric Insulator
---- etc., complete with all lead | No | 114.98 | 114.98 | 6.0 | False | None | None | False | None | False | 689.88 | 0 | 2963739 | 97970 | None | V-6 48 13.12 | Erection of 11 kV, 45 KN Polymeric Insulator
---- etc., complete with all lead | No | 63.44 | 63.44 | 6.0 | False | None | None | False | None | False | 380.64 | 0 | 2963740 | 97970 | None | V-6 4 2.16 | Supply of Spiral Earth Electrode
---- etc., complete with all lead | No | 315.86 | 315.86 | 4.0 | False | None | None | False | None | False | 1263.44 | 0 | 2963741 | 97970 | None | V-6 32 68.17 | Supply and fixing of Caution/Danger Board
---- etc., complete with all lead | No | 198.24 | 198.24 | 1.0 | False | None | None | False | None | False | 198.24 | 0 | 2963742 | 97970 | None | V-6 4 4.02 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete with all lead | Each | 117.62 | 117.62 | 2.0 | False | None | None | False | None | False | 235.24 | 0 | 2963743 | 97970 | None | V-6 45 5.09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire
---- etc., complete with all lead | Each | 55.51 | 55.51 | 2.0 | False | None | None | False | None | False | 111.02 | 0 | 2963744 | 97970 | None | V-6 11 24.05 | Supply and fixing of 11 kV, 400 Amps Double Break GOS
---- etc., complete with all lead | Set | 28097.22 | 28097.22 | 1.0 | False | None | None | False | None | False | 28097.22 | 0 | 2963745 | 97970 | None | V-6 11 24.07 | Supply and fixing of H-Frame for mounting GOS
---- etc., complete with all lead | Set | 8023.43 | 8023.43 | 1.0 | False | None | None | False | None | False | 8023.43 | 0 | 2963746 | 97970 | None | V-6 12 25.01 | Supply of DOLO Cut Out
---- etc., complete with all lead | Set of 3 Nos | 7764.4 | 7764.4 | 1.0 | False | None | None | False | None | False | 7764.4 | 0 | 2963747 | 97970 | None | V-6 12 13.01 |
Erection of DOLO Cut Out
---- etc., complete with all lead | Set of 3 Nos | 313.22 | 313.22 | 1.0 | False | None | None | False | None | False | 313.22 | 0 | 2963748 | 97970 | None | V-6 54 12.58.3 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip
---- etc., complete with all lead | m | 169.16 | 169.16 | 100.0 | False | None | None | False | None | False | 16916.0 | 0 | 2963749 | 97970 | None | V-6 55 12.58.9 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip
---- etc., complete with all lead | Mtr | 2171.39 | 2171.39 | 100.0 | False | None | None | False | None | False | 217139.0 | 0 | 2963750 | 97970 | None | V-6 20 45.07 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor
---- etc., complete with all lead | Set | 5374.95 | 5374.95 | 4.0 | False | None | None | False | None | False | 21499.8 | 0 | 2963751 | 97970 | None | V-6 20 45.04 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor
---- etc., complete with all lead | Set | 4147.18 | 4147.18 | 2.0 | False | None | None | False | None | False | 8294.36 | 0 | 2963752 | 97970 | None | V-6 15 36.01 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia)
---- etc., complete with all lead | Km | 1175782.59 | 1175782.59 | 0.25 | False | None | None | False | None | False | 293945.6475 | 0 | 2963753 | 97970 | None | V-6 16 38 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be welded to the Pole and block pipe at top and bottom as required including cost of all materials, labour, lead and lifts, cutting, bending wherever necessary, wastage and lapping etc., complete as per the direction of the engineer incharge for work including two coats of approved quality paint over one coat of primer paint.
---- etc., complete with all lead | Sqm | 1304.42 | 1304.42 | 150.0 | False | None | None | False | None | False | 195663.0 | 0 | 2963754 | 97970 | None | V-6 17 5.15.20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 800Amps 50kA
---- etc., complete with all lead | Each | 65947.84 | 65947.84 | 1.0 | False | None | None | False | None | False | 65947.84 | 0 | 2963755 | 97970 | None | V-6 42 10.1.13 | Supplying, installing, testing and commissioning of 250KVA/200kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf lag suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation max in static conditions IP 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on specialsheets in suitable approved shade and ---- etc., complete with all lead | Set | 2516750.63 | 2516750.63 | 1.0 | False | None | None | False | None | False | 2516750.63 | 0 | 2963756 | 97970 | None | V-6 33 10.2.7 | Supply, Erection, testing and commissioning of AMF panel suitable for .KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .amps 4 pole contactor for alternator with thermal O/L relay,. Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 250 KVA
---- etc., complete with all lead | Each | 371433.04 | 371433.04 | 1.0 | False | None | None | False | None | False | 371433.04 | 0 | 2963757 | 97970 | None | Approved Rate | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc.
---- etc., complete with all lead | m | 9440.0 | 9440.0 | 10.0 | False | None | None | False | None | False | 94400.0 | 0 | 2963758 | 97970 | None | Approved Rate | Supply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately.
---- etc., complete with all lead | Kg | 236.0 | 236.0 | 700.0 | False | None | None | False | None | False | 165200.0 | 0 | 2963759 | 97970 | None | Approved rate | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables
---- etc., complete with all lead | m | 236.0 | 236.0 | 100.0 | False | None | None | False | None | False | 23600.0 | 0 | 2963760 | 97970 | None | Approved Rate | Supplying and fixing of 800A, FP, 50kA, microprocessor based Motorised ACB electrical drawout type.over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs)
---- etc., complete with all lead | Each | 198240.0 | 198240.0 | 2.0 | False | None | None | False | None | False | 396480.0 | 0 | 2963761 | 97970 | None | Approved Rate | STREET LIGHTING PANEL-Fabricating, Supplying & Mounting M.S. Box made out of 16 SWG of size 700x750x220mm suitable for floor / wall mounting, fully weather proof with provision for better heat desipation, with two chambers & window for energy meter, provided with hinged front cover, two inside doors, with tamper proof locking arrangments, suitable size clamps with necessary cable entry pipe with gland and box should be finished with two coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. The box should be mounted on M.S.angle iron of size 40x40x6mm (total length 4.7 mtr) with 1:2:4 concreting (0.25x0.75x0.9 mtr) including coping. provision for housing 3 phase energy meter, suitable size bus bar, 100 A cut out (3 Nos), with timer (3-120sec) & contactorc) (60-70Amps), 63 A MCB TPN (1 No), 2 Nos 32 A TPN MCB on 4mm thick hylum sheet, wiring with suitable size copper wire & lugs. The box should be earthed with pipe type earthing. (AS PER PWD SR)
---- etc., complete with all lead | Set | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 2963762 | 97970 | None | Approved rate | Supply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 2 x30KVA Modular type UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 15 minutes back up on 60kva load with required VRLA SMF individual Battery bank System(65AH-32 Nos each Battery Bank) housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more.
---- etc., complete with all lead | Each | 1631940.0 | 1631940.0 | 1.0 | False | None | None | False | None | False | 1631940.0 | 0 | 2963763 | 97970 | None | Approved rate | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 50 Ports Providing PRI cards for Trunk lines / for tie line with reqd.software 16Analog Trunk Lines 4 Digital Extensions 20 Analogue Extensions( Expandable up to 50) In-Built Voicemail ( 4 Port & 80 Min) LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold .
---- etc., complete with all lead | No. | 141600.0 | 141600.0 | 1.0 | False | None | None | False | None | False | 141600.0 | 0 | 2963764 | 97970 | None | Approved rate | TELEPHONES Analog push button telephone with Caller ID, flash and radial
---- etc., complete with all lead | No | 2124.0 | 2124.0 | 35.0 | False | None | None | False | None | False | 74340.0 | 0 | 2963765 | 97970 | None | Approved rate | Supply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable (SM)
---- etc., complete with all lead | m | 115.64 | 115.64 | 100.0 | False | None | None | False | None | False | 11564.0 | 0 | 2963766 | 97970 | None | Approved rate | IP DOME CAMERASSupplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.
---- etc., complete with all lead | Each | 23836.0 | 23836.0 | 28.0 | False | None | None | False | None | False | 667408.0 | 0 | 2963767 | 97970 | None | Approved rate | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.
---- etc., complete with all lead | Each | 25606.0 | 25606.0 | 12.0 | False | None | None | False | None | False | 307272.0 | 0 | 2963768 | 97970 | None | Approved rate | IP PTZ CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.
---- etc., complete with all lead | Each | 177000.0 | 177000.0 | 2.0 | False | None | None | False | None | False | 354000.0 | 0 | 2963769 | 97970 | None | Approved Rate | Supplying, installation, testing and commissioning of SITC of complete 32 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC.
---- etc., complete with all lead | Each | 271400.0 | 271400.0 | 2.0 | False | None | None | False | None | False | 542800.0 | 0 | 2963770 | 97970 | None | Approved rate | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required
---- etc., complete with all lead | Each | 17110.0 | 17110.0 | 20.0 | False | None | None | False | None | False | 342200.0 | 0 | 2963771 | 97970 | None | Approved rate | Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required
---- etc., complete with all lead | Each | 47495.0 | 47495.0 | 4.0 | False | None | None | False | None | False | 189980.0 | 0 | 2963772 | 97970 | None | Approved rate | Supply and Installation of I/Os
---- etc., complete with all lead | Each | 147.5 | 147.5 | 200.0 | False | None | None | False | None | False | 29500.0 | 0 | 2963773 | 97970 | None | Approved rate | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required
---- etc., complete with all lead | Each | 265.5 | 265.5 | 60.0 | False | None | None | False | None | False | 15930.0 | 0 | 2963774 | 97970 | None | Approved rate | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required
---- etc., complete with all lead | Each | 336.3 | 336.3 | 60.0 | False | None | None | False | None | False | 20178.0 | 0 | 2963775 | 97970 | None | Approved rate | Supply and Installation of 6 Core Single Mode Ofc Cable The rate shall include all mounting accessories complete as required
---- etc., complete with all lead | m | 115.64 | 115.64 | 250.0 | False | None | None | False | None | False | 28910.0 | 0 | 2963776 | 97970 | None | Approved rate | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required
---- etc., complete with all lead | Each | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 2963777 | 97970 | None | Approved rate | The Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor.Booster amplifier.
---- etc., complete with all lead | Each | 3540.0 | 3540.0 | 4.0 | False | None | None | False | None | False | 14160.0 | 0 | 2963778 | 97970 | None | Approved rate | The Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor. 3 way splitter.
---- etc., complete with all lead | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 | 2963779 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of 'The Bedside call unit shall be mounted on the head boards where there are patient headboards or on the walls where it can be implemented within the system.'The Bedside call unit shall be 2 input\output ports for RJ45 Endings for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. 'On the standard bedside call unit front side there shall be: 'An "End Call" Button with a green tick mark symbol.'Reassurance backlight in order to give visual information about call ststus.'Continous backlight for easy visibility of the unit at night.'Pressing on the end call button ends the call and turns the assigned overdoor light to green. IP System controller logs the event as "Presence"'Pressing the end call button for the second time ends the "presence" and turns off the assigned overdoor light.'The Bedside Call Unit shall made from noninflammable PC-ABS-FR Materials.'It can be used individually as a call button where patient handset is not needed. Other wise, its connection with the patient handset shall be easily established ny the connecting via RJ45 on its front side.'A Nurse call shall be initated via the patient handset or the bedside call unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed.'If the unit is ablee to transmit the call to the zone controller, the LED on the unit shall flash with 1.0 second intervals, call transmission information shall be audibly notified to the patient.'If there is an error in the call transmission, a continuous red light showing error status shall only stop when the call termination button is pressed, subsequent presses of the button shall trigger an audio alert each time.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller.
---- etc., complete with all lead | No | 4130.0 | 4130.0 | 40.0 | False | None | None | False | None | False | 165200.0 | 0 | 2963780 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of PATIENT HANDSET BASIC.This Handset will be used in the locations that are connected to the system by a zone controller.'It Shall be ergonomically suitable to be handheld.'It shall be connected to the bedside call unit with an independent cable.'on its front side there shall be 'A "start Call" Button with red nurse symbol.'Reassurance LED light in order to give visual information about the call status.Continues LED Light for easy visibility at night.'Call Initation and error notification procedures is the same as bedside call unit except audio alerts are always issued by the bedside call unit its call initiation button and back light works in parallel with the one on the bedside call unit.It shall have an easily cleanable surface that dose not promote bacterial growth.Patient handset shall be made from non inflammable PC-ABS-FR Materials.
---- etc., complete with all lead | No | 5900.0 | 5900.0 | 40.0 | False | None | None | False | None | False | 236000.0 | 0 | 2963781 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of CODE BLIE CALL UNIT;- The Code Blue Call Unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. The Code Blue Call Unit has 2 Input/Output ports for RJ45 endings for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller.
On the Code Blue call unit front side there shall be; A “start code blue” button with a blue medicine symbol. Pressing the button initiates a Code Blue event, turning on the assigned Overdoor lights to Blue. An “end code blue” button with a green tick mark symbol. Pressing the Button shall cancel the Code blue alarm turning the assigned Overdoor lights. Reassurance backlight in order to give visual information about the call status. Continuous backlight for easy visibility of the unit at night.
The Code Blue Call Unit shall be made from nonflammable PC-ABS-FR materials.
If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient.
If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard."
---- etc., complete with all lead | No | 4071.0 | 4071.0 | 40.0 | False | None | None | False | None | False | 162840.0 | 0 | 2963782 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of PULL-CORD CALL UNIT(WC\Bathroom)-The Pull-cord call unit has 2 input\output ports for RJ45 Ending for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. on its front side there shall be A pull-code call unit with customizable length with minimum 1.5 meters to serve as a call-code.A call termination button (indicated by a green tick Mark Symbol).Its Connection shall be made with CAT6 UTP cable and RJ45 of B standard.A priority WC Emergency call shall start when the cord is pulled.This Device will be used in the locations that are connected to the system by a zone controller.
---- etc., complete with all lead | No | 4189.0 | 4189.0 | 10.0 | False | None | None | False | None | False | 41890.0 | 0 | 2963783 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of 'Over Door Light shall use environmentally friendly LEDs.'It shall consist of Red, Green, Blue, white, Pink Colored Warning Light.'In Normal Condition, no light shall be lit, if the patient makes nurse call, Red Light shall be Lit with in 0.5 Seconds. After all nurse call, when the nurse presses the green presence button on the call unit, the light of the over door light will return green.'In code blue, the blue light shall be lit.'The outer casing of the over door light shall be made of nonflammble PC-ABS-FR Materials.'Over door light shall have 2 input\output ports for RJ45 ending for cabling in a chain with call units on one of the communication lines of the zone controller. Alternativley, it connects to the RCU in private & semi private rooms.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller or black colored communication ports of RCU unit to which it is connected. It shall not require additional energy supply.
---- etc., complete with all lead | No | 11463.7 | 11463.7 | 10.0 | False | None | None | False | None | False | 114637.0 | 0 | 2963784 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of 'IP BASED NURSE CALL SYSTEM Supply, Installation, testing and commissioning of the IP based Nurse Call System based on the following components including but not restricted to gold plated connecting leads, connectors, patch cables, jumpers, nuts, screws, bolts, mounting plates, cover plates, back boxes etc., 'Shall be in accordance with International guidelines and shall be in such a way that the most effective communication between Patient, Nursing Staff, Doctor & management staff can be provided in the least possible time. 'System Operation\Ward Nurse Station;-'The ward Nurse Station Shall be used in the location that are connected to the system by a zone controller. It is placed in each multi bed ward areas at the nurse station overlooking the patent beds.'The ward Nurse station Shall have a minimum 10 Inch touchscreen and include its own integrated handsfree voice communication with other Nurse control Panels.'The Nurse control panel may be used to monitor the status of every assigned call points, call and alarm status.the screen will show active calls and emergency code with top to bottom priority, highest priority active calls is on top and longest awaiting calls within same call type having more priority than same type.'The origin room and the bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type.'onscreen call points shall have notification of relevant icons, colors, and tones according to their call status as well as time the call started and time passed since.'call shall be shown real time. Each activity will be send to IP System Controller for logging enabling later inspection and reporting.'Time stamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System controller.'Emergency codeblue, Red, pink, and white shall be initiated from the touch screen.
---- etc., complete with all lead | No | 95138.68 | 95138.68 | 3.0 | False | None | None | False | None | False | 285416.04 | 0 | 2963785 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of IP ZONE CONTROLLER This is the main node device used to network the Nurse call system devices to each other for areas are not private or semi-private rooms and do not have item 3.2(RCU). It is to be used for multi bed wards areas in a single open soace with a nurse desk overlooking the assigned patient beds.Each zone controller has 2 communication ports which support chains of up to 24 calls initiation devices each,and up to as many over door lights as the number of the call initiation devices, for a total maximum support of 48 call devices.The connection shall be made with cat 6 UTP Cable and RJ45 of B Standard. Toatl cable length from the Zone Controller to the last call device Cannot be longer than 500 meters for each communication line oneach communication port.Zone controller shall have 2 power injectors to be included with the device to be used for injecting 12V power to be used on each communication line. Each power injector has 2 R Ports to be connected at suitable location to prevent voltage drops on the lines.Each Power injector require 110 240 V Power.There shall not be any limits to the number of zone controllers that can be used in a nurse call system, they may be placed in the network switch, its connection shall be made with cat 6 UTP cable and of B Standard.The zone controller shall have 1 port for 110240 V Power.The zone controller must be configurable from the IP System Controller
---- etc., complete with all lead | No | 85388.34 | 85388.34 | 3.0 | False | None | None | False | None | False | 256165.02 | 0 | 2963786 | 97970 | None | Approved rate | Supply, installation, testing and commissioning of 500 kVA , 11kV/433V, 3 phase, 50 Hz, Delta star, DYn11 , outdoor, natually cooled, Oil Immersed copper double wound transformer Conforming to IS: 1180 1180 3 LEVEL Contained in mild steel radiator Cooled tank with first fill of oil as per IS: 335 with On load tap changer from +5% to 15% in steps of remote tap changes panel with AVR, class F insulation, Rating and Diagram Plate, Earthing Terminals - 2 Nos,Liffting Lugs,Air release hole with plug,Dehydrating Silica Gel Breather,Prismatic Oil level Guage,Oil Conservator with drain plug,Thermometer pocket,Jacking Lugs,Bottom drain cum filter valve,Top filter valve,4 Nos. Bi-Directional rollers,Pressure relief device,Marshalling Box [wherever applicable],100 mm OTI/ 150 mm OTI with alarm & trip,WTI with alarm and trip,Buchholz Relay with alarm and trip,Shut off valves for Buchholz Relay,Magnetic Oil Level guage,Radiators - Fixed / Detachable With HT & LT Cable end boxes / Provison for LV Bus Duct type, The transformer shall have suitable enclosure for providing neutral CT on earthed star point with connector for connection to REF relay provided in Main panel. All routing test as per IS shall be conducted on the transformer. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation & efficient Cooling, required Danger boards, signages, lettering etc. The enclosure shall be Epoxy Powder coated. The transformer shall be subjected to all routine tests as per IS/IEC standards. Type test certificate shall be submitted (As Per EC BC Norms)
---- etc., complete with all lead | Each | 433989.84 | 433989.84 | 1.0 | False | None | None | False | None | False | 433989.84 | 0 |
| 1709811496000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK HOSPITAL AT MANGALURU, KARNATAKA- WATER SUPPLY AND SANITORY WORKS | 5696002.83 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2963787 | 97971 | None | V-2 125 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines(Basemet Floor)
---- etc., complete with all lead | m | 401.77 | 401.77 | 40.0 | False | None | None | False | None | False | 16070.8 | 0 | 2963788 | 97971 | None | V-2 125 13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work50mm dia pipes, From sink & urinal waste lines (Basemet Floor)
---- etc., complete with all lead | m | 510.14 | 510.14 | 30.0 | False | None | None | False | None | False | 15304.2 | 0 | 2963789 | 97971 | None | V-2 128 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 75mm nominal dia pipes
( Internal drainage) (Basemet Floor)
---- etc., complete with all lead | m | 381.94 | 381.94 | 165.0 | False | None | None | False | None | False | 63020.1 | 0 | 2963790 | 97971 | None | V-2 128 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.110mm nominal dia pipes
( Internal drainage) (Basemet Floor)
---- etc., complete with all lead | m | 508.82 | 508.82 | 135.0 | False | None | None | False | None | False | 68690.7 | 0 | 2963791 | 97971 | None | V-2 128 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Basemet Floor)
---- etc., complete with all lead | Nos. | 322.47 | 322.47 | 3.0 | False | None | None | False | None | False | 967.41 | 0 | 2963792 | 97971 | None | V-2 128 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Basemet Floor)
---- etc., complete with all lead | Nos | 1612.35 | 1612.35 | 2.0 | False | None | None | False | None | False | 3224.7 | 0 | 2963793 | 97971 | None | V-2 131 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Basemet Floor)
---- etc., complete with all lead | Nos | 14396.19 | 14396.19 | 2.0 | False | None | None | False | None | False | 28792.38 | 0 | 2963794 | 97971 | None | V-2 119 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (Basemet Floor)
---- etc., complete with all lead | Nos | 958.16 | 958.16 | 3.0 | False | None | None | False | None | False | 2874.48 | 0 | 2963795 | 97971 | None | V-2 132 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps (Basemet Floor)
---- etc., complete with all lead | Nos | 401.77 | 401.77 | 2.0 | False | None | None | False | None | False | 803.54 | 0 | 2963796 | 97971 | None | V-2 135 14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. (Basemet Floor)
---- etc., complete with all lead | Nos | 1070.5 | 1070.5 | 2.0 | False | None | None | False | None | False | 2141.0 | 0 | 2963797 | 97971 | None | V-2 118 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) (Basemet Floor)
---- etc., complete with all lead | Nos | 109.69 | 109.69 | 2.0 | False | None | None | False | None | False | 219.38 | 0 | 2963798 | 97971 | None | V-2 13 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g (Basemet Floor)
---- etc., complete with all lead | Nos | 404.41 | 404.41 | 2.0 | False | None | None | False | None | False | 808.82 | 0 | 2963799 | 97971 | None | V-2 137 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g (Basemet Floor)
---- etc., complete with all lead | Nos | 118.94 | 118.94 | 2.0 | False | None | None | False | None | False | 237.88 | 0 | 2963800 | 97971 | None | V-2 115 13.21 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore
(Basemet Floor)
---- etc., complete with all lead | Nos | 377.98 | 377.98 | 2.0 | False | None | None | False | None | False | 755.96 | 0 | 2963801 | 97971 | None | V-2 122 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes
(Basemet Floor)
---- etc., complete with all lead | m | 399.12 | 399.12 | 18.0 | False | None | None | False | None | False | 7184.16 | 0 | 2963802 | 97971 | None | V2 122 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
(Basemet Floor)
---- etc., complete with all lead | m | 500.89 | 500.89 | 25.0 | False | None | None | False | None | False | 12522.25 | 0 | 2963803 | 97971 | None | V-2 125 13.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines
(Ground Floor)
---- etc., complete with all lead | m | 401.77 | 401.77 | 55.0 | False | None | None | False | None | False | 22097.35 | 0 | 2963804 | 97971 | None | V-2 125 13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work50mm dia pipes, From sink & urinal waste lines
(Ground Floor)
---- etc., complete with all lead | m | 510.14 | 510.14 | 10.0 | False | None | None | False | None | False | 5101.4 | 0 | 2963805 | 97971 | None | V-2 128 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.75mm nominal dia pipes
( Internal drainage) (Ground Floor)
---- etc., complete with all lead | m | 381.94 | 381.94 | 80.0 | False | None | None | False | None | False | 30555.2 | 0 | 2963806 | 97971 | None | V-2 128 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.110mm nominal dia pipes
( Internal drainage) (Ground Floor)
---- etc., complete with all lead | m | 508.82 | 508.82 | 60.0 | False | None | None | False | None | False | 30529.2 | 0 | 2963807 | 97971 | None | V-2 128 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Ground Floor)
---- etc., complete with all lead | Nos | 322.47 | 322.47 | 33.0 | False | None | None | False | None | False | 10641.51 | 0 | 2963808 | 97971 | None | V-2 123 13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (Ground Floor)
---- etc., complete with all lead | Nos | 413.66 | 413.66 | 28.0 | False | None | None | False | None | False | 11582.48 | 0 | 2963809 | 97971 | None | V-2 128 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Ground Floor)
---- etc., complete with all lead | Nos | 1612.35 | 1612.35 | 13.0 | False | None | None | False | None | False | 20960.55 | 0 | 2963810 | 97971 | None | V-2 118 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :150 mm diameter
(Ground Floor)
---- etc., complete with all lead | Nos | 368.73 | 368.73 | 5.0 | False | None | None | False | None | False | 1843.65 | 0 | 2963811 | 97971 | None | V-2 135 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (Ground Floor)
---- etc., complete with all lead | Nos | 7350.74 | 7350.74 | 5.0 | False | None | None | False | None | False | 36753.7 | 0 | 2963812 | 97971 | None | V-2 137 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour "600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g (Ground Floor)
---- etc., complete with all lead | Nos | 655.51 | 655.51 | 5.0 | False | None | None | False | None | False | 3277.55 | 0 | 2963813 | 97971 | None | V-2 137 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g (Ground Floor)
---- etc., complete with all lead | Nos | 191.63 | 191.63 | 5.0 | False | None | None | False | None | False | 958.15 | 0 | 2963814 | 97971 | None | V-2 119 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (Ground Floor)
---- etc., complete with all lead | Nos | 819.39 | 819.39 | 28.0 | False | None | None | False | None | False | 22942.92 | 0 | 2963815 | 97971 | None | V-2 131 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Ground Floor)
---- etc., complete with all lead | Nos | 14396.19 | 14396.19 | 14.0 | False | None | None | False | None | False | 201546.66 | 0 | 2963816 | 97971 | None | V-2 131 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern (Ground Floor)
---- etc., complete with all lead | Nos | 5886.41 | 5886.41 | 6.0 | False | None | None | False | None | False | 35318.46 | 0 | 2963817 | 97971 | None | V-2 119 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (Ground Floor)
---- etc., complete with all lead | Nos | 958.16 | 958.16 | 48.0 | False | None | None | False | None | False | 45991.68 | 0 | 2963818 | 97971 | None | V-2 132 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps (Ground Floor)
---- etc., complete with all lead | Nos | 4073.17 | 4073.17 | 11.0 | False | None | None | False | None | False | 44804.87 | 0 | 2963819 | 97971 | None | V-2 135 14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. (Ground Floor)
---- etc., complete with all lead | Nos | 1070.5 | 1070.5 | 26.0 | False | None | None | False | None | False | 27833.0 | 0 | 2963820 | 97971 | None | V-2 118 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) (Ground Floor)
---- etc., complete with all lead | Nos | 109.69 | 109.69 | 26.0 | False | None | None | False | None | False | 2851.94 | 0 | 2963821 | 97971 | None | V-2 137 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g (Ground Floor)
---- etc., complete with all lead | Nos | 404.41 | 404.41 | 26.0 | False | None | None | False | None | False | 10514.66 | 0 | 2963822 | 97971 | None | V-2 137 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g (Ground Floor)
---- etc., complete with all lead | Nos | 118.94 | 118.94 | 26.0 | False | None | None | False | None | False | 3092.44 | 0 | 2963823 | 97971 | None | V-3 116 13.2.1 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore
(Ground Floor)
---- etc., complete with all lead | Nos | 377.98 | 377.98 | 32.0 | False | None | None | False | None | False | 12095.36 | 0 | 2963824 | 97971 | None | V-2 122 13.32.1 | Providing and laying flooring and steps fine dressed granite stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes
(Ground Floor)
---- etc., complete with all lead | m | 399.12 | 399.12 | 40.0 | False | None | None | False | None | False | 15964.8 | 0 | 2963825 | 97971 | None | V2 122 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc20 mm nominal dia Pipes
. (Ground Floor)
---- etc., complete with all lead | m | 500.89 | 500.89 | 65.0 | False | None | None | False | None | False | 32557.85 | 0 | 2963826 | 97971 | None | V2 122 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
(Ground Floor)
---- etc., complete with all lead | m | 630.4 | 630.4 | 78.0 | False | None | None | False | None | False | 49171.2 | 0 | 2963827 | 97971 | None | V2 122 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.32 mm nominal dia pipes
(Ground Floor)
---- etc., complete with all lead | m | 736.13 | 736.13 | 30.0 | False | None | None | False | None | False | 22083.9 | 0 | 2963828 | 97971 | None | V-2 122 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 40 mm nominal dia Pipes
(Ground Floor)
---- etc., complete with all lead | m | 708.38 | 708.38 | 30.0 | False | None | None | False | None | False | 21251.4 | 0 | 2963829 | 97971 | None | V2 122 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 50 mm nominal dia Pipes
(Ground Floor) ---- etc., complete with all lead | m | 1032.17 | 1032.17 | 15.0 | False | None | None | False | None | False | 15482.55 | 0 | 2963830 | 97971 | None | V2 122 13.33.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal dia Pipes
(Ground Floor)
---- etc., complete with all lead | m | 491.64 | 491.64 | 120.0 | False | None | None | False | None | False | 58996.8 | 0 | 2963831 | 97971 | None | V2 122 13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work40 mm nominal dia Pipes
(Ground Floor)
---- etc., complete with all lead | m | 630.4 | 630.4 | 135.0 | False | None | None | False | None | False | 85104.0 | 0 | 2963832 | 97971 | None | V2 122 13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal dia Pipes
(Ground Floor)
---- etc., complete with all lead | m | 952.87 | 952.87 | 290.0 | False | None | None | False | None | False | 276332.3 | 0 | 2963833 | 97971 | None | V-2 115 13.5.2 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
: (Ground Floor)
---- etc., complete with all lead | Nos | 900.01 | 900.01 | 28.0 | False | None | None | False | None | False | 25200.28 | 0 | 2963834 | 97971 | None | V-2 117 13.4.2 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)32 mm nominal bore
: (Ground Floor)
---- etc., complete with all lead | Nos | 785.03 | 785.03 | 25.0 | False | None | None | False | None | False | 19625.75 | 0 | 2963835 | 97971 | None | V-2 117 13.4.3 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bore
: (Ground Floor)
---- etc., complete with all lead | Nos | 927.76 | 927.76 | 15.0 | False | None | None | False | None | False | 13916.4 | 0 | 2963836 | 97971 | None | V-2 117 13.4.4 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end)50 mm nominal bore
: (Ground Floor)
---- etc., complete with all lead | Nos | 1129.97 | 1129.97 | 10.0 | False | None | None | False | None | False | 11299.7 | 0 | 2963837 | 97971 | None | V-2 117 13.4.5 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 65 mm nominal bore
: (Ground Floor)
---- etc., complete with all lead | Nos | 1864.78 | 1864.78 | 8.0 | False | None | None | False | None | False | 14918.24 | 0 | 2963838 | 97971 | None | Ele7.3.3 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding
300L ---- etc., complete with all lead | Nos | 82583.48 | 82583.48 | 4.0 | False | None | None | False | None | False | 330333.92 | 0 | 2963839 | 97971 | None | V-2 125 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 40mm dia pipes, From wash basin waste lines
(First Floor)
---- etc., complete with all lead | m | 405.78 | 405.78 | 45.0 | False | None | None | False | None | False | 18260.1 | 0 | 2963840 | 97971 | None | V-2 125 13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50mm dia pipes, From sink & urinal waste lines
(First Floor)
---- etc., complete with all lead | m | 515.24 | 515.24 | 10.0 | False | None | None | False | None | False | 5152.4 | 0 | 2963841 | 97971 | None | V-2 128 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage) 75mm nominal dia pipes
(First Floor)
---- etc., complete with all lead | m | 385.76 | 385.76 | 65.0 | False | None | None | False | None | False | 25074.4 | 0 | 2963842 | 97971 | None | V-2 128 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes
( Internal drainage) (First Floor)
---- etc., complete with all lead | m | 513.9 | 513.9 | 50.0 | False | None | None | False | None | False | 25695.0 | 0 | 2963843 | 97971 | None | V-2 128 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (First Floor)
---- etc., complete with all lead | Nos | 325.7 | 325.7 | 39.0 | False | None | None | False | None | False | 12702.3 | 0 | 2963844 | 97971 | None | V-2 123 13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (First Floor)
---- etc., complete with all lead | Nos | 417.8 | 417.8 | 25.0 | False | None | None | False | None | False | 10445.0 | 0 | 2963845 | 97971 | None | V-2 128 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (First Floor)
---- etc., complete with all lead | Nos | 1628.48 | 1628.48 | 15.0 | False | None | None | False | None | False | 24427.2 | 0 | 2963846 | 97971 | None | V-2 118 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter
: (First Floor)
---- etc., complete with all lead | Nos | 372.41 | 372.41 | 8.0 | False | None | None | False | None | False | 2979.28 | 0 | 2963847 | 97971 | None | V-2 135 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (First Floor)
---- etc., complete with all lead | Nos | 7424.25 | 7424.25 | 8.0 | False | None | None | False | None | False | 59394.0 | 0 | 2963848 | 97971 | None | V-3 138 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour (First Floor)
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g (First Floor)
---- etc., complete with all lead | Nos | 662.07 | 662.07 | 8.0 | False | None | None | False | None | False | 5296.56 | 0 | 2963849 | 97971 | None | V-2 137 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g (First Floor)
---- etc., complete with all lead | Nos | 193.55 | 193.55 | 8.0 | False | None | None | False | None | False | 1548.4 | 0 | 2963850 | 97971 | None | V-2 119 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (First Floor)
---- etc., complete with all lead | Nos | 827.59 | 827.59 | 48.0 | False | None | None | False | None | False | 39724.32 | 0 | 2963851 | 97971 | None | V-2 131 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (First Floor)
---- etc., complete with all lead | Nos | 14540.15 | 14540.15 | 17.0 | False | None | None | False | None | False | 247182.55 | 0 | 2963852 | 97971 | None | V-2 131 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern (First Floor)
---- etc., complete with all lead | Nos | 5945.27 | 5945.27 | 5.0 | False | None | None | False | None | False | 29726.35 | 0 | 2963853 | 97971 | None | V-2 119 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (First Floor)
---- etc., complete with all lead | Nos | 967.74 | 967.74 | 42.0 | False | None | None | False | None | False | 40645.08 | 0 | 2963854 | 97971 | None | V-2 132 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps (First Floor)
---- etc., complete with all lead | Nos | 4113.9 | 4113.9 | 10.0 | False | None | None | False | None | False | 41139.0 | 0 | 2963855 | 97971 | None | V-2 135 14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. (First Floor)
---- etc., complete with all lead | Nos | 1081.2 | 1081.2 | 28.0 | False | None | None | False | None | False | 30273.6 | 0 | 2963856 | 97971 | None | V-2 118 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) (First Floor)
---- etc., complete with all lead | Nos | 110.79 | 110.79 | 28.0 | False | None | None | False | None | False | 3102.12 | 0 | 2963857 | 97971 | None | V-2 137 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g (First Floor)
---- etc., complete with all lead | Nos | 408.45 | 408.45 | 28.0 | False | None | None | False | None | False | 11436.6 | 0 | 2963858 | 97971 | None | V-2 137 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g (Ground Floor)
---- etc., complete with all lead | Nos | 120.13 | 120.13 | 31.0 | False | None | None | False | None | False | 3724.03 | 0 | 2963859 | 97971 | None | V-3 116 13.2.1 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore
(First Floor)
---- etc., complete with all lead | Nos | 381.76 | 381.76 | 20.0 | False | None | None | False | None | False | 7635.2 | 0 | 2963860 | 97971 | None | V-2 122 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes
(First Floor)
---- etc., complete with all lead | m | 403.11 | 403.11 | 35.0 | False | None | None | False | None | False | 14108.85 | 0 | 2963861 | 97971 | None | V2 122 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
(First Floor)
---- etc., complete with all lead | m | 505.9 | 505.9 | 45.0 | False | None | None | False | None | False | 22765.5 | 0 | 2963862 | 97971 | None | V2 122 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes
(First Floor)
---- etc., complete with all lead | m | 636.71 | 636.71 | 68.0 | False | None | None | False | None | False | 43296.28 | 0 | 2963863 | 97971 | None | V2 122 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.32 mm nominal dia pipes
(First Floor)
---- etc., complete with all lead | m | 758.22 | 758.22 | 40.0 | False | None | None | False | None | False | 30328.8 | 0 | 2963864 | 97971 | None | V-2 122 13.31.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 40 mm nominal dia Pipes
(First Floor) ---- etc., complete with all lead | m | 715.46 | 715.46 | 30.0 | False | None | None | False | None | False | 21463.8 | 0 | 2963865 | 97971 | None | V2 122 13.31.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 50 mm nominal dia Pipes
(First Floor)
---- etc., complete with all lead | m | 1042.49 | 1042.49 | 20.0 | False | None | None | False | None | False | 20849.8 | 0 | 2963866 | 97971 | None | V-2 125 13.50.5 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.40mm dia pipes, From wash basin waste lines
(Second Floor)
---- etc., complete with all lead | m | 409.8 | 409.8 | 25.0 | False | None | None | False | None | False | 10245.0 | 0 | 2963867 | 97971 | None | V-2 125 13.50.6 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work.50mm dia pipes, From sink & urinal waste lines
(Second Floor)
---- etc., complete with all lead | m | 520.34 | 520.34 | 8.0 | False | None | None | False | None | False | 4162.72 | 0 | 2963868 | 97971 | None | V-2 128 13.64.1 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.75mm nominal dia pipes
( Internal drainage) (Second Floor)
---- etc., complete with all lead | m | 389.58 | 389.58 | 50.0 | False | None | None | False | None | False | 19479.0 | 0 | 2963869 | 97971 | None | V-2 128 13.64.2 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 110mm nominal dia pipes
( Internal drainage) (Second Floor)
---- etc., complete with all lead | m | 518.99 | 518.99 | 40.0 | False | None | None | False | None | False | 20759.6 | 0 | 2963870 | 97971 | None | V-2 128 13.63 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete (Second Floor)
---- etc., complete with all lead | Nos | 328.92 | 328.92 | 18.0 | False | None | None | False | None | False | 5920.56 | 0 | 2963871 | 97971 | None | V-2 123 13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. (Second Floor)
---- etc., complete with all lead | Nos | 421.93 | 421.93 | 10.0 | False | None | None | False | None | False | 4219.3 | 0 | 2963872 | 97971 | None | V-2 128 14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (Second Floor)
---- etc., complete with all lead | Nos | 1644.6 | 1644.6 | 8.0 | False | None | None | False | None | False | 13156.8 | 0 | 2963873 | 97971 | None | V-2 118 13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter
: (Second Floor)
---- etc., complete with all lead | Nos | 376.1 | 376.1 | 3.0 | False | None | None | False | None | False | 1128.3 | 0 | 2963874 | 97971 | None | V-2 135 14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (Second Floor)
---- etc., complete with all lead | Nos | 7497.75 | 7497.75 | 3.0 | False | None | None | False | None | False | 22493.25 | 0 | 2963875 | 97971 | None | V-3 138 14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour
600 mm long towel rail with total length of 645 mm, width 78 mm and eSFective height of 88 mm, weighing not less than 190 g (Second Floor)
---- etc., complete with all lead | Nos | 668.62 | 668.62 | 3.0 | False | None | None | False | None | False | 2005.86 | 0 | 2963876 | 97971 | None | V-2 137 14.38 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 g (Second Floor)
---- etc., complete with all lead | Nos | 195.46 | 195.46 | 3.0 | False | None | None | False | None | False | 586.38 | 0 | 2963877 | 97971 | None | V-2 119 13.16 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 (Second Floor)
---- etc., complete with all lead | Nos | 835.78 | 835.78 | 15.0 | False | None | None | False | None | False | 12536.7 | 0 | 2963878 | 97971 | None | V-2 131 14.2.1 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (Second Floor)
---- etc., complete with all lead | Nos | 14684.11 | 14684.11 | 7.0 | False | None | None | False | None | False | 102788.77 | 0 | 2963879 | 97971 | None | V-2 131 14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern (Second Floor)
---- etc., complete with all lead | Nos | 6004.13 | 6004.13 | 3.0 | False | None | None | False | None | False | 18012.39 | 0 | 2963880 | 97971 | None | V-2 119 13.15 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. (Second Floor)
---- etc., complete with all lead | Nos | 977.32 | 977.32 | 18.0 | False | None | None | False | None | False | 17591.76 | 0 | 2963881 | 97971 | None | V-2 132 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps (Second Floor)
---- etc., complete with all lead | Nos | 4154.63 | 4154.63 | 5.0 | False | None | None | False | None | False | 20773.15 | 0 | 2963882 | 97971 | None | V-2 135 14.22A | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. (Second Floor)
---- etc., complete with all lead | Nos | 1091.91 | 1091.91 | 15.0 | False | None | None | False | None | False | 16378.65 | 0 | 2963883 | 97971 | None | V-2 118 13.8.1.1 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) (Second Floor)
---- etc., complete with all lead | Nos | 412.5 | 412.5 | 15.0 | False | None | None | False | None | False | 6187.5 | 0 | 2963884 | 97971 | None | V-2 137 14.37.1 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, eSFective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g (Second Floor)
---- etc., complete with all lead | Nos | 412.5 | 412.5 | 15.0 | False | None | None | False | None | False | 6187.5 | 0 | 2963885 | 97971 | None | V-2 137 14.36.1 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 g (Second Floor)
---- etc., complete with all lead | Nos | 121.32 | 121.32 | 15.0 | False | None | None | False | None | False | 1819.8 | 0 | 2963886 | 97971 | None | V-3 116 13.2.1 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore
(Second Floor)
---- etc., complete with all lead | Nos | 385.54 | 385.54 | 20.0 | False | None | None | False | None | False | 7710.8 | 0 | 2963887 | 97971 | None | V-2 13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal dia Pipes
(Second Floor)
---- etc., complete with all lead | m | 407.11 | 407.11 | 10.0 | False | None | None | False | None | False | 4071.1 | 0 | 2963888 | 97971 | None | V2 13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc20 mm nominal dia Pipes
. (Second Floor)
---- etc., complete with all lead | m | 510.9 | 510.9 | 18.0 | False | None | None | False | None | False | 9196.2 | 0 | 2963889 | 97971 | None | V2 13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia pipes
(Second Floor)
---- etc., complete with all lead | Nos | 544.92 | 544.92 | 68.0 | False | None | None | False | None | False | 37054.56 | 0 | 2963890 | 97971 | None | V2 13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc32 mm nominal dia pipes
. (Second Floor)
---- etc., complete with all lead | m | 750.85 | 750.85 | 30.0 | False | None | None | False | None | False | 22525.5 | 0 | 2963891 | 97971 | None | V-2 7 1.4.1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m
---- etc., complete with all lead | Cum | 319.83 | 319.83 | 341.0 | False | None | None | False | None | False | 109062.03 | 0 | 2963892 | 97971 | None | V-1 7 1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
---- etc., complete with all lead | Cum | 572.25 | 572.25 | 341.0 | False | None | None | False | None | False | 195137.25 | 0 | 2963893 | 97971 | None | V-5 114 10.3.7 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for:Pipes of SN8 Self Fit - 160mm dia.
---- etc., complete with all lead | m | 815.43 | 815.43 | 154.0 | False | None | None | False | None | False | 125576.22 | 0 | 2963894 | 97971 | None | V-5 115 10.3.8 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. forPipes of SN8 Self Fit - 200mm dia.
:
---- etc., complete with all lead | m | 1176.22 | 1176.22 | 120.0 | False | None | None | False | None | False | 141146.4 | 0 | 2963895 | 97971 | None | V-5 114 10.3.9 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for Pipes of SN8 Self Fit - 250mm dia.
:
---- etc., complete with all lead | m | 1807.95 | 1807.95 | 80.0 | False | None | None | False | None | False | 144636.0 | 0 | 2963896 | 97971 | None | V-6 114 10.2.4 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN4, 160mm dia.
---- etc., complete with all lead | m | 761.24 | 761.24 | 186.0 | False | None | None | False | None | False | 141590.64 | 0 | 2963897 | 97971 | None | V-5 191 16.9 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.
---- etc., complete with all lead | Nos | 7208.01 | 7208.01 | 22.0 | False | None | None | False | None | False | 158576.22 | 0 | 2963898 | 97971 | None | V-2 123 13.38 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber 100mm x 100mm size P type with Non Modular common burnt clay bricks of designation 3.5& water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
---- etc., complete with all lead | Nos | 3346.29 | 3346.29 | 19.0 | False | None | None | False | None | False | 63579.51 | 0 | 2963899 | 97971 | None | V-5 194 16.18.6 | Construction of RCC Machinehole chambers of 1:1.5:3 proportion or approved type Cast-insitu / Pre-cast RCC Machinehole chambers, constructed using form vibrators of standard type, with barricading, danger lighting and using of sight rails and boning rods wherever necessary, shoring and strutting wherever required using Ordinary Port Land Cement, using 1:1.5:3 proportion RCC with 20 mm and down graded jelly, well graded sand and steel of approved quality, 200 mm thick top concrete slab, having wall thickness and raft thickness as in approved drawings and with an offset in raft alround the chamber as in approved drawing, benching concrete with 1:6 slope towards the central drain finished smooth, including fixing and grouting of pipes, including conveying to work spot supply and fixing SFRC Machinehole cover and frame (Heavy duty) conforming to IS:12592 with latest amendments, on a bed of CC 1:2:4 Providing and fixing of minimum 3 mm thick encapsulated plastic footsteps (as per IS 10910) on 12 mm dia. Grade Fe-500 steel bar (as per IS 1786) staggered at 300 mm apart as detailed in Technical specifications, including stone grit beding wherever required, watering, curing, engraving Machinehole number with flow direction on the inner cylindrical surface etc., complete including cost of reinforcement steel and fabrication charges and also cost and conveyance of all materials, labour with all lead and lifts. The Pre-cast RCC Machinehole are for various diamters and depths as stated below and as per detailed drawings, specifications and direction of the Engineer. For 1.2m dia Machinehole:Constructing Pre-cast RCC Machinehole 1.2 m internal dia. ,3.0M depth & SFRC cover & frame
---- etc., complete with all lead | Nos | 103729.74 | 103729.74 | 3.0 | False | None | None | False | None | False | 311189.22 | 0 | 2963900 | 97971 | None | V-2 118 13.23.5 | Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball 50 mm nominal bore, 242mm long, weighing not less than 1240 g
---- etc., complete with all lead | Nos | 1776.23 | 1776.23 | 3.0 | False | None | None | False | None | False | 5328.69 | 0 | 2963901 | 97971 | None | V5 86 7.5.1 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete For DI/CI puddle flanges of 80mm dia.
.
---- etc., complete with all lead | Nos | 2088.13 | 2088.13 | 8.0 | False | None | None | False | None | False | 16705.04 | 0 | 2963902 | 97971 | None | V5 86 7.5.2 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete For DI/CI puddle flanges of 100mm dia.
.
---- etc., complete with all lead | Nos | 2459.5 | 2459.5 | 6.0 | False | None | None | False | None | False | 14757.0 | 0 | 2963903 | 97971 | None | V5 86 7.5.3 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .For DI/CI puddle flanges of 150mm dia.
---- etc., complete with all lead | Nos | 3130.87 | 3130.87 | 4.0 | False | None | None | False | None | False | 12523.48 | 0 | 2963904 | 97971 | None | V5 86 7.5.5 | Providing and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .
For DI/CI puddle flanges of 250mm dia.
---- etc., complete with all lead | Nos | 5960.42 | 5960.42 | 3.0 | False | None | None | False | None | False | 17881.26 | 0 | 2963905 | 97971 | None | V-5 247 21.1.10 | Water purification plants: Supplying, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each componentsFor (For 1000 LPH FRP : Skid) Type (HOSPITAL )
---- etc., complete with all lead | Nos | 549785.6 | 549785.6 | 1.0 | False | None | None | False | None | False | 549785.6 | 0 | 2963906 | 97971 | None | 13.40.1 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (2 HP, Size 65x50 Head 13M, Discharge 462 LPM)
---- etc., complete with all lead | Nos | 20630.18 | 20630.18 | 4.0 | False | None | None | False | None | False | 82520.72 | 0 | 2963907 | 97971 | None | V5 156 13.32 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and
equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work
---- etc., complete with all lead | Job | 8590.4 | 8590.4 | 10.0 | False | None | None | False | None | False | 85904.0 | 0 | 2963908 | 97971 | None | V5 157 13.40.3 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (3 HP, size 50x40 Head 30M, Discharge 198 LPM)
---- etc., complete with all lead | Nos | 24867.23 | 24867.23 | 2.0 | False | None | None | False | None | False | 49734.46 | 0 | 2963909 | 97971 | None | V5 157 13.40.5 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. ( 5 HP, size 50x40 Head 46M, Discharge 174 LPM)
---- etc., complete with all lead | Nos | 34912.71 | 34912.71 | 4.0 | False | None | None | False | None | False | 139650.84 | 0 | 2963910 | 97971 | None | Approved rate | Air Vent Cowel 75mm
---- etc., complete with all lead | Nos | 350.0 | 350.0 | 16.0 | False | None | None | False | None | False | 5600.0 | 0 | 2963911 | 97971 | None | Approved rate | Air Vent Cowel 110mm
---- etc., complete with all lead | Nos | 500.0 | 500.0 | 16.0 | False | None | None | False | None | False | 8000.0 | 0 | 2963912 | 97971 | None | Approved rate | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap with extension pipe, CP wall flanges, 2 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent )
---- etc., complete with all lead | Nos | 7897.0 | 7897.0 | 33.0 | False | None | None | False | None | False | 260601.0 | 0 | 2963913 | 97971 | None | Approved rate | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. ( Jaguar make or Equalent ).
---- etc., complete with all lead | Nos | 1850.0 | 1850.0 | 40.0 | False | None | None | False | None | False | 74000.0 | 0 |
| 1709811496000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK HOSPITAL AT MANGALURU, KARNATAKA-FIRE-FIGHTING SYSTEM WORKS | 3693233.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2963914 | 97972 | None | V-6 68 15.22 | Supply and installation of 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg, empty weight 1.7 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,8,C and electrically started Fire, 8 Rating 218, Can construction: Deep drawn &Co., Mig welded, valve Construciton: Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 2.00 MM, 5 years warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets & accessories if it is fixing on wall, labour, usage charges of machinery complete as per specifications. complete IS15683 and CE Approved.
---- etc., complete with all lead | Each | 8590.4 | 8590.4 | 6.0 | False | None | None | False | None | False | 51542.4 | 0 | 2963915 | 97972 | None | V-6 72 15.33 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete
---- etc., complete with all lead | Each | 7268.8 | 7268.8 | 5.0 | False | None | None | False | None | False | 36344.0 | 0 | 2963916 | 97972 | None | V-6 74 15.4 | Providing Aqueous Film-Forming Foam - 9 Ltr
Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6
Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster
Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete
---- etc., complete with all lead | Each | 10704.96 | 10704.96 | 2.0 | False | None | None | False | None | False | 21409.92 | 0 | 2963917 | 97972 | None | V-6 62 15.4 | Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50,
Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5
Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees,
Controllable discharge mechanism (Squeeze grip with easy snap safety seal),
Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire,
A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved,
---- etc., complete with all lead | Each | 3766.56 | 3766.56 | 9.0 | False | None | None | False | None | False | 33899.04 | 0 | 2963918 | 97972 | None | V-6 72 15.34 | Supply, installation in position, testing and commissioning of 4.5Kg C0 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete
---- etc., complete with all lead | Each | 8590.4 | 8590.4 | 9.0 | False | None | None | False | None | False | 77313.6 | 0 | 2963919 | 97972 | None | V-6 93 15.112 | Supplying of two bucket stand alongwith buckets. complete
---- etc., complete with all lead | Each | 1453.76 | 1453.76 | 4.0 | False | None | None | False | None | False | 5815.04 | 0 | 2963920 | 97972 | None | PWD SR -21-22 14 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm)
---- etc., complete with all lead | Sq CM | 2.64 | 2.64 | 6000.0 | False | None | None | False | None | False | 15840.0 | 0 | 2963921 | 97972 | None | PWD SR -21-22 14 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.)
---- etc., complete with all lead | Sq CM | 2.64 | 2.64 | 6000.0 | False | None | None | False | None | False | 15840.0 | 0 | 2963922 | 97972 | None | PWD SR 21-22 14 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(signage with text FIRE EXIT,Size shall be 15cm x 60cm.)
---- etc., complete with all lead | Sq CM | 2.64 | 2.64 | 7200.0 | False | None | None | False | None | False | 19008.0 | 0 | 2963923 | 97972 | None | V-6 92 15.106 | A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.
B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS.
C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.
E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
---- etc., complete with all lead | Each | 3304.0 | 3304.0 | 8.0 | False | None | None | False | None | False | 26432.0 | 0 | 2963924 | 97972 | None | PWD SR 92 15.106 | ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.
A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM.
B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor)
C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE.
D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.
E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor)
F) FIRE FIGHTING AGENCY:
PHONE :(Current phone numbers to be provided in this location by the contractor)
FAX : (Current fax numbers to be provided in this location by the contractor)
---- etc., complete with all lead | Each | 3304.0 | 3304.0 | 8.0 | False | None | None | False | None | False | 26432.0 | 0 | 2963925 | 97972 | None | PWD SR 21-22 14 15.72 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size)
---- etc., complete with all lead | Each | 2.64 | 2.64 | 9000.0 | False | None | None | False | None | False | 23760.0 | 0 | 2963926 | 97972 | None | V-6 92 15.108.3 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 40 Zone cansole. Complete
---- etc., complete with all lead | Nos | 107049.6 | 107049.6 | 1.0 | False | None | None | False | None | False | 107049.6 | 0 | 2963927 | 97972 | None | V-6 93 15.109 | P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front
---- etc., complete with all lead | Nos | 46586.4 | 46586.4 | 1.0 | False | None | None | False | None | False | 46586.4 | 0 | 2963928 | 97972 | None | V-6 93 15.109 | Supplying Installing, testing and commissioning of MIKE
---- etc., complete with all lead | Each | 7268.8 | 7268.8 | 1.0 | False | None | None | False | None | False | 7268.8 | 0 | 2963929 | 97972 | None | V-6 92 15.107 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.
---- etc., complete with all lead | Each | 3237.92 | 3237.92 | 8.0 | False | None | None | False | None | False | 25903.36 | 0 | 2963930 | 97972 | None | CPWD-21-22 15.105 | Supply & Laying of 2 X 1.5 Sqmm fire alarm armored cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
---- etc., complete with all lead | Mtr | 182.31 | 182.31 | 800.0 | False | None | None | False | None | False | 145848.0 | 0 | 2963931 | 97972 | None | V-6 84 15.66.1 | FIRE ALARM SYSTEM
"Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS
integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std." 2 Loop Panel
---- etc., complete with all lead | Each | 277536.0 | 277536.0 | 3.0 | False | None | None | False | None | False | 832608.0 | 0 | 2963932 | 97972 | None | V-6 15.103 | Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications.
---- etc., complete with all lead | Each | 330.4 | 330.4 | 50.0 | False | None | None | False | None | False | 16520.0 | 0 | 2963933 | 97972 | None | V-6 84 15.67 | Supply, Installation , Testing & Commissioning of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked. Approval: UL/VDS/EN54. Make:
---- etc., complete with all lead | Each | 85904.0 | 85904.0 | 1.0 | False | None | None | False | None | False | 85904.0 | 0 | 2963934 | 97972 | None | PWD SR 21-22 15.66 | Supply, intallation, testing and Commissioning of loop card - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
---- etc., complete with all lead | Each | 3700.48 | 3700.48 | 3.0 | False | None | None | False | None | False | 11101.44 | 0 | 2963935 | 97972 | None | V-6 92 15.1 | Supply Installation testing & Commissioning of conventional type photo Heat electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20 C to +60 C. IP Rating at IP 23D & Approval with EN 54 7, LPCB Approved. ---- etc., complete with all lead | Each | 2775.36 | 2775.36 | 280.0 | False | None | None | False | None | False | 777100.8 | 0 | 2963936 | 97972 | None | V-6 84 15.68 | Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10 C to +55 C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) ---- etc., complete with all lead | Each | 6475.84 | 6475.84 | 8.0 | False | None | None | False | None | False | 51806.72 | 0 | 2963937 | 97972 | None | V-6 85 15.73 | Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function.
---- etc., complete with all lead | Each | 3964.8 | 3964.8 | 8.0 | False | None | None | False | None | False | 31718.4 | 0 | 2963938 | 97972 | None | ELE-SR - 23-24 2 1.4.2 | Supplying and fixing sheet Metal box made out of 18 SWGsheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm
---- etc., complete with all lead | Each | 155.95 | 155.95 | 280.0 | False | None | None | False | None | False | 43666.0 | 0 | 2963939 | 97972 | None | PWD SR 85 15.72 | Supply, install, test and commissioning of Analogue addressable Monitor Cum Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED indicator, approved to operate in 10 C to +55 C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54.
---- etc., complete with all lead | Each | 5154.24 | 5154.24 | 8.0 | False | None | None | False | None | False | 41233.92 | 0 | 2963940 | 97972 | None | CPWD - 21-22 17.5.2 | Supply, intallation, testing and Commissioning of 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws (RED colour)
---- etc., complete with all lead | Mtr | 228.64 | 228.64 | 1800.0 | False | None | None | False | None | False | 411552.0 | 0 | 2963941 | 97972 | None | PWD SR-21-22 90 15.113 | SITC of 7AM-12 V Battery for fire alarm system
---- etc., complete with all lead | Each | 1415.43 | 1415.43 | 6.0 | False | None | None | False | None | False | 8492.58 | 0 | 2963942 | 97972 | None | Approved rate | Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth - including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work
---- etc., complete with all lead | No | 58410.0 | 58410.0 | 1.0 | False | None | None | False | None | False | 58410.0 | 0 | 2963943 | 97972 | None | CPWD 17.2.2 | Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc
---- etc., complete with all lead | Each | 265127.5 | 265127.5 | 1.0 | False | None | None | False | None | False | 265127.5 | 0 | 2963944 | 97972 | None | Approved rate | Supply, intallation, testing and Commissioning of Network card for fire alram panels integration
---- etc., complete with all lead | Each | 88500.0 | 88500.0 | 3.0 | False | None | None | False | None | False | 265500.0 | 0 | 2963945 | 97972 | None | Approved rate | SITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories.
---- etc., complete with all lead | Each | 7080.0 | 7080.0 | 15.0 | False | None | None | False | None | False | 106200.0 | 0 |
| 1709811496000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK HOSPITAL AT MANGALURU, KARNATAKA-HVAC SYSTEM WORKS | 16578701.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2963946 | 97973 | None | V-6 6.8.4 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit.5 star 1.0 Ton Capacity.
---- etc., complete with all lead | Nos | 62851.33 | 62851.33 | 2.0 | False | None | None | False | None | False | 125702.66 | 0 | 2963947 | 97973 | None | V-6 6.8.5 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit.
5 star 1.5 Ton Capacity.
---- etc., complete with all lead | Nos | 74478.77 | 74478.77 | 15.0 | False | None | None | False | None | False | 1117181.55 | 0 | 2963948 | 97973 | None | V-6 6.8.6 | Supplying of . TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit.
5 star 2.0 Ton capacity.
---- etc., complete with all lead | Nos | 89074.52 | 89074.52 | 13.0 | False | None | None | False | None | False | 1157968.76 | 0 | 2963949 | 97973 | None | V-6 6.9.3 | Supply, erection, testing, commissioning of Supplying, Erecting, Testing, commissioning of sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit.
2.0 TR Cassette 1 Ph
---- etc., complete with all lead | Nos | 104161.9 | 104161.9 | 1.0 | False | None | None | False | None | False | 104161.9 | 0 | 2963950 | 97973 | None | V-6 6.9.4 | Supply, erection, testing, commissioning of Supplying, Erecting, Testing, commissioning of sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit.
3.0 TR Cassette 3 Ph
---- etc., complete with all lead | Nos | 138922.63 | 138922.63 | 1.0 | False | None | None | False | None | False | 138922.63 | 0 | 2963951 | 97973 | None | V-6 6.10.2 | Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.
5.5 TR
---- etc., complete with all lead | Nos | 149484.85 | 149484.85 | 3.0 | False | None | None | False | None | False | 448454.55 | 0 | 2963952 | 97973 | None | V-6 6.12 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable angle iron support upto 3.0 Ton split/cassette type A/C.
---- etc., complete with all lead | Nos | 4196.08 | 4196.08 | 30.0 | False | None | None | False | None | False | 125882.4 | 0 | 2963953 | 97973 | None | V-6 6.13.1 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube.
Split
---- etc., complete with all lead | Rmtr | 2047.16 | 2047.16 | 130.0 | False | None | None | False | None | False | 266130.8 | 0 | 2963954 | 97973 | None | V-6 6.13.2 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube.
Cassette
---- etc., complete with all lead | Rmtr | 2166.1 | 2166.1 | 30.0 | False | None | None | False | None | False | 64983.0 | 0 | 2963955 | 97973 | None | V-6 6.25.1 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.
24 Gauge
---- etc., complete with all lead | Sqm | 2393.42 | 2393.42 | 1100.0 | False | None | None | False | None | False | 2632762.0 | 0 | 2963956 | 97973 | None | V-6 6.25.2 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.
22 Gauge
---- etc., complete with all lead | Sqm | 2803.11 | 2803.11 | 50.0 | False | None | None | False | None | False | 140155.5 | 0 | 2963957 | 97973 | None | V-6 6.26 | Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts.
---- etc., complete with all lead | Sqm | 1574.03 | 1574.03 | 900.0 | False | None | None | False | None | False | 1416627.0 | 0 | 2963958 | 97973 | None | V-6 6.27 | Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories.
---- etc., complete with all lead | Nos | 6031.78 | 6031.78 | 15.0 | False | None | None | False | None | False | 90476.7 | 0 | 2963959 | 97973 | None | V-6 6.29.1 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.
Aluminium Diffusers
---- etc., complete with all lead | Nos | 6711.08 | 6711.08 | 260.0 | False | None | None | False | None | False | 1744880.8 | 0 | 2963960 | 97973 | None | V-6 6.29.2 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.
Collar Dampers
---- etc., complete with all lead | Nos | 3467.88 | 3467.88 | 130.0 | False | None | None | False | None | False | 450824.4 | 0 | 2963961 | 97973 | None | V-6 6.29.3 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.
GI Mixing Box
---- etc., complete with all lead | Nos | 8293.04 | 8293.04 | 25.0 | False | None | None | False | None | False | 207326.0 | 0 | 2963962 | 97973 | None | V-6 6.29.4 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.
Flexible Duct Per Mtr
---- etc., complete with all lead | Nos | 2236.15 | 2236.15 | 25.0 | False | None | None | False | None | False | 55903.75 | 0 | 2963963 | 97973 | None | V-6 6.30.2 | Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware etc.,. Complete.
6" Extruded aluminium grille with 15 deg to 30 deg louvers.
---- etc., complete with all lead | Rmtr | 2249.36 | 2249.36 | 30.0 | False | None | None | False | None | False | 67480.8 | 0 | 2963964 | 97973 | None | V-6 SR-5.1 | Supplying push button operated direct online starter with anantiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overloadrelay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for230/440 V 1/3 phase motor upto 5 HP.
---- etc., complete with all lead | Nos | 2546.72 | 2546.72 | 15.0 | False | None | None | False | None | False | 38200.8 | 0 | 2963965 | 97973 | None | Approved rate | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with greaterthank 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec.Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns as per IS 7613,.The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type.The AHU to be selected that the noise level not to exceed 60 dBA at 1.5meter distance from the AHU cabinet in all directions. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, power & communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. The frame structure shall be mounted on MS plate & serrated rubber pads,with nitrile rubber insulation, UPVC drain piping and termination, valves and insulation and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 3.0 TR / 1,200 CFM with 50 TSP - 0.75 Kw for CSU's and 1x3.0 - Condensing units with necessary KIT
---- etc., complete with all lead | Nos | 172044.0 | 172044.0 | 3.0 | False | None | None | False | None | False | 516132.0 | 0 | 2963966 | 97973 | None | Approved rate | 5.5 TR / 2,200 CFM with 50 TSP - 1.5 Kw for CSU's and 1x5.5 - Condensing units with necessary KIT. (Location - As per the site condition)
---- etc., complete with all lead | No | 215586.0 | 215586.0 | 1.0 | False | None | None | False | None | False | 215586.0 | 0 | 2963967 | 97973 | None | Approved rate | 8.5 TR / 3,400 CFM with 50 TSP - 1.5 Kw for CSU's and 1x8.5 - Condensing units with necessary KIT. (Location - As per the site condition)
---- etc., complete with all lead | No | 317538.0 | 317538.0 | 2.0 | False | None | None | False | None | False | 635076.0 | 0 | 2963968 | 97973 | None | Approved rate | 11.0 TR / 4,400 CFM with 50 TSP - 2.2 Kw for CSU's and 1x11.0 - Condensing units with necessary KIT. (Location - As per the site condition)
---- etc., complete with all lead | No | 373824.0 | 373824.0 | 3.0 | False | None | None | False | None | False | 1121472.0 | 0 | 2963969 | 97973 | None | Approved rate | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23 2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger. The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods. The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
2,500 CFM / 40 mm TSP / 1.1 kW
---- etc., complete with all lead | Nos | 84960.0 | 84960.0 | 1.0 | False | None | None | False | None | False | 84960.0 | 0 | 2963970 | 97973 | None | Approved rate | 3,500 CFM / 40 mm TSP / 1.1 kW
---- etc., complete with all lead | Nos | 118000.0 | 118000.0 | 2.0 | False | None | None | False | None | False | 236000.0 | 0 | 2963971 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
150 CFM / 20mm TSP.
---- etc., complete with all lead | Nos | 9440.0 | 9440.0 | 3.0 | False | None | None | False | None | False | 28320.0 | 0 | 2963972 | 97973 | None | Approved rate | 300 CFM / 20mm TSP.
---- etc., complete with all lead | Nos | 10738.0 | 10738.0 | 2.0 | False | None | None | False | None | False | 21476.0 | 0 | 2963973 | 97973 | None | Approved rate | 500 CFM / 20mm TSP.
---- etc., complete with all lead | Nos | 12980.0 | 12980.0 | 2.0 | False | None | None | False | None | False | 25960.0 | 0 | 2963974 | 97973 | None | Approved rate | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Refrigerant copper Piping quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Refrigerant copper Piping quantity (Rmt) should be taken as per site condition only.
1/4"" (6.35 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick)"
---- etc., complete with all lead | Rmtr | 1062.0 | 1062.0 | 170.0 | False | None | None | False | None | False | 180540.0 | 0 | 2963975 | 97973 | None | Approved rate | 3/8 (9.52 mm) X 21 Swg (0.8mm) - Soft drawn (Insulation = 13mm thick)
---- etc., complete with all lead | Rmtr | 1180.0 | 1180.0 | 65.0 | False | None | None | False | None | False | 76700.0 | 0 | 2963976 | 97973 | None | Approved rate | 1/2 (12.7 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick)
---- etc., complete with all lead | Rmtr | 1298.0 | 1298.0 | 285.0 | False | None | None | False | None | False | 369930.0 | 0 | 2963977 | 97973 | None | Approved rate | 5/8 (15.9 mm) X 19 Swg (1 mm) - Soft drawn (Insulation = 13mm thick)
---- etc., complete with all lead | Rmtr | 1416.0 | 1416.0 | 45.0 | False | None | None | False | None | False | 63720.0 | 0 | 2963978 | 97973 | None | Approved rate | 7/8 ( 22.2 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick)
---- etc., complete with all lead | Rmtr | 1652.0 | 1652.0 | 60.0 | False | None | None | False | None | False | 99120.0 | 0 | 2963979 | 97973 | None | Approved rate | 1 1/8 (28.6 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick)
---- etc., complete with all lead | Rmtr | 1770.0 | 1770.0 | 75.0 | False | None | None | False | None | False | 132750.0 | 0 | 2963980 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Open cell ""Class-1"" Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL-181 and E2180 , Density 140-180Kg / m3, UL94 approved (HBF, HF 1 & HF 2) in accordance to UL 94,1996. Thermal conductivity 0.047 W / MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 1071-05 (section 12.7). Moisture resistant-joining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier. Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer. 15mm Thick
---- etc., complete with all lead | Sqm | 1121.0 | 1121.0 | 200.0 | False | None | None | False | None | False | 224200.0 | 0 | 2963981 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Closed cell ""Class-O"" Nitrile rubber Insulation with Factroy Laminated Alu-foil with Ultrafresh Antimicrobial protection with both side skin/smooth surface, As per ASTM G21, ASTM G22, UL-181 and E2180. Class “O” IMO A 653 (16), FM Global, UL 94 & EPA approved,with Density 40-60kg / m3. Temperature of -50 to 116 Deg C and As per EN12667(DIN 52612). Thermal conductivity of 0.036 W / m K @ 0 deg C. Water vapour permeability as per EN12086 (DIN 52615) , Moisture Resistance Factor = 7000. Aluminum foil tape of 75mm width should be used to seal the joints with self adhesive tape (Black Cotton Tape not acceptable). Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement) Material shall be FM approved and preferred color shall be Black.
Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
Note: Costing is inclusive of necessary support like cup and washer with scaffolding arrangements to install the underdeck insulation.
25mm Thick (Under Deck Insulation)
---- etc., complete with all lead | Sqm | 944.0 | 944.0 | 625.0 | False | None | None | False | None | False | 590000.0 | 0 | 2963982 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Factory fabricated powder coated Double skin plenum. Outer skin constructed with not less than 0.63mm thick GI sheet and the inner sheet shall be of not less than 0.63mm GI plain sheet., with 25mm thick sandwiched RPUF (CFC free) insulation of density not less than 40kg m3. And with necessary High grade Extruded Aluminum cross supports for rigidity and cutouts for duct & AHU connections.
Note:
a) The Plenum shall be provided with as Access Door. (Size are not less then 800mmx600mm)
b) These plenum is inside the AHU Rooms should be supported with special acoustic hangers to avoid transmission of vibaration from AHU Room to adjacent sensitive areas.
c) Color of the Plenum should match the color of AHU & CSU installed at site. ---- etc., complete with all lead | Sqm | 5310.0 | 5310.0 | 25.0 | False | None | None | False | None | False | 132750.0 | 0 | 2963983 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Fire damper with opposed blade (Fusible link type). Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link & spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C.
(Area calculation : (L x B)
---- etc., complete with all lead | Sqm | 12980.0 | 12980.0 | 6.5 | False | None | None | False | None | False | 84370.0 | 0 | 2963984 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc.,
(Area calculation : (L x B)
---- etc., complete with all lead | Sqm | 8260.0 | 8260.0 | 10.0 | False | None | None | False | None | False | 82600.0 | 0 | 2963985 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications.
(Area calculation : (L x B)
---- etc., complete with all lead | Sqm | 9440.0 | 9440.0 | 1.0 | False | None | None | False | None | False | 9440.0 | 0 | 2963986 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange.
250 dia
---- etc., complete with all lead | Nos | 2124.0 | 2124.0 | 25.0 | False | None | None | False | None | False | 53100.0 | 0 | 2963987 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Extruded Aluminum powder coated Exhaust air Disc valves/grille without volume control dampers for Pantry. a) Note: Colour shall be as per the False ceiling or Architect intent.
150 mm Dia
---- etc., complete with all lead | Nos | 1180.0 | 1180.0 | 25.0 | False | None | None | False | None | False | 29500.0 | 0 | 2963988 | 97973 | None | Approved rate | Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges.
Note: Colour shall be as per the False ceiling or Architect intent.
---- etc., complete with all lead | Sqm | 9440.0 | 9440.0 | 5.0 | False | None | None | False | None | False | 47200.0 | 0 | 2963989 | 97973 | None | Approved rate | Supply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers. (Used in supplay air)
---- etc., complete with all lead | Sqm | 6490.0 | 6490.0 | 3.0 | False | None | None | False | None | False | 19470.0 | 0 | 2963990 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
40 mm dia
---- etc., complete with all lead | Rmtr | 531.0 | 531.0 | 25.0 | False | None | None | False | None | False | 13275.0 | 0 | 2963991 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
32 mm dia
---- etc., complete with all lead | Rmtr | 472.0 | 472.0 | 150.0 | False | None | None | False | None | False | 70800.0 | 0 | 2963992 | 97973 | None | Approved data rate | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
25 mm dia
---- etc., complete with all lead | Rmtr | 354.0 | 354.0 | 350.0 | False | None | None | False | None | False | 123900.0 | 0 | 2963993 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Blanc Pumps (External) for Hi-Wall units. (Max. flow 12L/h & Head is 10Met)
---- etc., complete with all lead | No | 7965.0 | 7965.0 | 30.0 | False | None | None | False | None | False | 238950.0 | 0 | 2963994 | 97973 | None | Approved rate | Mini Tank Pump (Less then 5.0 TR CSU/FCU) - (Max. flow 35L/h & Head is 15Met)
---- etc., complete with all lead | No | 9440.0 | 9440.0 | 3.0 | False | None | None | False | None | False | 28320.0 | 0 | 2963995 | 97973 | None | Approved rate | Max Hi-Flow (Above 5.0 TR CSU/FCU) - (Max. flow 550L/h & Head is 5Met)
---- etc., complete with all lead | No | 11682.0 | 11682.0 | 9.0 | False | None | None | False | None | False | 105138.0 | 0 | 2963996 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp) Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
1.5 Kw
---- etc., complete with all lead | No | 7434.0 | 7434.0 | 15.0 | False | None | None | False | None | False | 111510.0 | 0 | 2963997 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp) Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
3.0 Kw
---- etc., complete with all lead | No | 10620.0 | 10620.0 | 10.0 | False | None | None | False | None | False | 106200.0 | 0 | 2963998 | 97973 | None | Approved rate | Supply, Installation, Testing & Commissioning of Magnehelic Differential Pressure Gages (IP-67 enclosure) to Indicate Positive, Negative or Differential, Accurate within 1%. Note: Pressures must be less than 35 psi.Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations. Costing is inclusive of with necessary fittings and Pitot Tube and etc. AHU/CSU Filter Section
---- etc., complete with all lead | No | 9440.0 | 9440.0 | 9.0 | False | None | None | False | None | False | 84960.0 | 0 | 2963999 | 97973 | None | Approved data rate | Supply, Installation, Testing & Commissioning of Duct Type Temperature & RH Sensors (IP-40 enclosure) (Immersion depth : 230 mm) with all mounting accessories to measure the Return Air temperatures. (Temperature range R.H. range 10% to 90%) Note : Used for AHU's, CSU's FCU's & Cassette units.
---- etc., complete with all lead | No | 8850.0 | 8850.0 | 9.0 | False | None | None | False | None | False | 79650.0 | 0 | 2964000 | 97973 | None | Approved data rate | Supply, Installation, Testing & Commissioning of Room Type Temperature & RH Digital Sensors (Thermostats) with all mounting accessories to measure the critical Room air temperatures. (Temperature range : -20 degree C to 60 degree C & R.H. range 0% to 99%)
---- etc., complete with all lead | No | 8850.0 | 8850.0 | 9.0 | False | None | None | False | None | False | 79650.0 | 0 | 2964001 | 97973 | None | Approved rate | Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units.
Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Electrical Power cabling quantity (Rmt) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Electrical Power cabling quantity (Rmt) should be taken as per site condition only.
3.0 Core x 2.5 Sqmm - For AHU/CSU/Ventilation units units. (Can be used up to 3.7 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment.
---- etc., complete with all lead | Rmtr | 413.0 | 413.0 | 150.0 | False | None | None | False | None | False | 61950.0 | 0 |
| 1709811496000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK HOSPITAL AT MANGALURU, KARNATAKA MODULAR OT | 5959768.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2964002 | 97974 | None | Approved rate | Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab.
Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile.
The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
MODULAR OT area -8 mtr X6 mtr apprxt.
Say 50.00 Sqm
---- etc., complete with all lead | Sqm | 10354.5 | 10354.5 | 50.0 | False | None | None | False | None | False | 517725.0 | 0 | 2964003 | 97974 | None | Approved rate | Providing and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
6 mtr X 3 mtr X2 Nos. =36 Sqmtr
8 mtr X 3 mtr X2 Nos. =48 Sqmtr
Say 84.00 Sqm
( Door area will be detected form wall panel)
---- etc., complete with all lead | Sqm | 10354.5 | 10354.5 | 84.0 | False | None | None | False | None | False | 869778.0 | 0 | 2964004 | 97974 | None | Approved rate | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Srub Door /Dirty utility Door (single leaf)
1 mtr X 2.10 mtr
Say 2.10 Sqmtr
---- etc., complete with all lead | Sqm | 53843.4 | 53843.4 | 2.1 | False | None | None | False | None | False | 113071.14 | 0 | 2964005 | 97974 | None | Approved rate | Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
---- etc., complete with all lead | Sqm | 3835.0 | 3835.0 | 54.0 | False | None | None | False | None | False | 207090.0 | 0 | 2964006 | 97974 | None | Approved rate | Supplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF 0.9, line voltage @ 50Hz, driver efficiency 85% & THD15%. LED Efficiency 130 Im/W & Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition
---- etc., complete with all lead | Each | 9725.56 | 9725.56 | 8.0 | False | None | None | False | None | False | 77804.48 | 0 | 2964007 | 97974 | None | Approved rate | Supplying and Fixing LED X-Ray Viewing Screen :X-RAY VIEWING SCREEN: Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X ray viewing screen shall be concealed with wall panel.
---- etc., complete with all lead | Each | 33040.0 | 33040.0 | 1.0 | False | None | None | False | None | False | 33040.0 | 0 | 2964008 | 97974 | None | Approved rate | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel.
---- etc., complete with all lead | Each | 6903.0 | 6903.0 | 1.0 | False | None | None | False | None | False | 6903.0 | 0 | 2964009 | 97974 | None | Approved rate | Plenum Laminar Flow :
Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos. (Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete.
---- etc., complete with all lead | Each | 312700.0 | 312700.0 | 1.0 | False | None | None | False | None | False | 312700.0 | 0 | 2964010 | 97974 | None | Approved rate | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units.
---- etc., complete with all lead | Each | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 2964011 | 97974 | None | Approved rate | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories.
---- etc., complete with all lead | Each | 76700.0 | 76700.0 | 1.0 | False | None | None | False | None | False | 76700.0 | 0 | 2964012 | 97974 | None | Approved rate | Supplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following
1. Medical gas card
2. Laminar Air flow controls Temperature & humidity indicators, filter status, temperature & humidity control.
3. Digital elapsed timer
4. Hand free phone
5. Digital day timer clock
6. Lighting control panel
---- etc., complete with all lead | Each | 129800.0 | 129800.0 | 1.0 | False | None | None | False | None | False | 129800.0 | 0 | 2964013 | 97974 | None | Approved rate | Providing & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete.
---- etc., complete with all lead | Each | 4130.0 | 4130.0 | 4.0 | False | None | None | False | None | False | 16520.0 | 0 | 2964014 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories.
---- etc., complete with all lead | Each | 21240.0 | 21240.0 | 4.0 | False | None | None | False | None | False | 84960.0 | 0 | 2964015 | 97974 | None | Approved rate | Supplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete.
---- etc., complete with all lead | Each | 7375.0 | 7375.0 | 1.0 | False | None | None | False | None | False | 7375.0 | 0 | 2964016 | 97974 | None | Approved rate | AHU's RECYCLE SYSTEM FOR OT AREA AS PER NABH NORMS
SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, ( EFF1 Motor ) coil should be 5. 5 TR x 2 circute with all concted accessories.
---- etc., complete with all lead | No | 597788.0 | 597788.0 | 1.0 | False | None | None | False | None | False | 597788.0 | 0 | 2964017 | 97974 | None | Approved rate | AIR COOLED CONDENSER UNIT & COPPER PIPING
SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU) provided with necessary controls.like Thermostart , Draier with MS painted stand
---- etc., complete with all lead | No | 146320.0 | 146320.0 | 2.0 | False | None | None | False | None | False | 292640.0 | 0 | 2964018 | 97974 | None | Approved rate | GRILLE & DAMPER
SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size
---- etc., complete with all lead | Sqm | 10384.0 | 10384.0 | 2.0 | False | None | None | False | None | False | 20768.0 | 0 | 2964019 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts
---- etc., complete with all lead | Sqm | 13924.0 | 13924.0 | 2.0 | False | None | None | False | None | False | 27848.0 | 0 | 2964020 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 DEGREEC for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop.
---- etc., complete with all lead | No | 6254.0 | 6254.0 | 1.0 | False | None | None | False | None | False | 6254.0 | 0 | 2964021 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth
---- etc., complete with all lead | No | 5546.0 | 5546.0 | 2.0 | False | None | None | False | None | False | 11092.0 | 0 | 2964022 | 97974 | None | Approved rate | DUCTING & INSULATION
SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges.
22 guage
---- etc., complete with all lead | Sqm | 2006.0 | 2006.0 | 160.0 | False | None | None | False | None | False | 320960.0 | 0 | 2964023 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade
13 mm thk for return air duct
---- etc., complete with all lead | Sqm | 920.4 | 920.4 | 80.0 | False | None | None | False | None | False | 73632.0 | 0 | 2964024 | 97974 | None | Approved rate | SUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser
---- etc., complete with all lead | Rmtr | 979.4 | 979.4 | 20.0 | False | None | None | False | None | False | 19588.0 | 0 | 2964025 | 97974 | None | Approved rate | 25 mm PVC dia drain piping with supports for AHUs
---- etc., complete with all lead | Rmtr | 625.4 | 625.4 | 50.0 | False | None | None | False | None | False | 31270.0 | 0 | 2964026 | 97974 | None | Approved rate | ELECTRICAL & CONTROLLS
SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller
For AHU
---- etc., complete with all lead | Set | 12272.0 | 12272.0 | 1.0 | False | None | None | False | None | False | 12272.0 | 0 | 2964027 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60%
---- etc., complete with all lead | Set | 66788.0 | 66788.0 | 1.0 | False | None | None | False | None | False | 66788.0 | 0 | 2964028 | 97974 | None | Approved rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 6 Sqmm
---- etc., complete with all lead | Mtr | 218.3 | 218.3 | 60.0 | False | None | None | False | None | False | 13098.0 | 0 | 2964029 | 97974 | None | Approved rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 4 Sqmm
---- etc., complete with all lead | Mtr | 177.0 | 177.0 | 60.0 | False | None | None | False | None | False | 10620.0 | 0 | 2964030 | 97974 | None | Approved rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 2.5 Sqmm
---- etc., complete with all lead | Mtr | 123.9 | 123.9 | 30.0 | False | None | None | False | None | False | 3717.0 | 0 | 2964031 | 97974 | None | Approved rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
8C X 2.5 Sqmm S.R.
---- etc., complete with all lead | Mtr | 348.1 | 348.1 | 30.0 | False | None | None | False | None | False | 10443.0 | 0 | 2964032 | 97974 | None | Approved rate | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP
4C X 10 Sqmm
---- etc., complete with all lead | Mtr | 348.1 | 348.1 | 30.0 | False | None | None | False | None | False | 10443.0 | 0 | 2964033 | 97974 | None | Approved rate | SUPPLY & Fixing Cable trey
300 width x 50 ht perforated
---- etc., complete with all lead | Rmtr | 645.46 | 645.46 | 30.0 | False | None | None | False | None | False | 19363.8 | 0 | 2964034 | 97974 | None | Approved rate | Plate COpper Earthing strip 24 x 3 mm connected to existing earthing
---- etc., complete with all lead | Rmtr | 617.14 | 617.14 | 50.0 | False | None | None | False | None | False | 30857.0 | 0 | 2964035 | 97974 | None | Approved rate | SUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure
---- etc., complete with all lead | No | 10089.0 | 10089.0 | 1.0 | False | None | None | False | None | False | 10089.0 | 0 | 2964036 | 97974 | None | Approved rate | DSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters
---- etc., complete with all lead | No | 9735.0 | 9735.0 | 2.0 | False | None | None | False | None | False | 19470.0 | 0 | 2964037 | 97974 | None | Approved rate | Supplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets (8 Nos), Data Points (1 Nos) and Medical Gas Outlets (7 Nos), 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V Stand
---- etc., complete with all lead | No | 194700.0 | 194700.0 | 1.0 | False | None | None | False | None | False | 194700.0 | 0 | 2964038 | 97974 | None | Approved rate | Supply , installation, testing and commissioning Double arm moveable pendant for surgeon with connected accessories.
The Pendants shall comply with NFPA 99C/HTM 02 01/DIN/EN/ISO 7396-1 as amended up to the last date of receipt of tenders. The support arms shall be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.
Double moveable arms (any combination) with total coverage of min 1800 mm and minimum 330DEGREE Each arm shall have ability of horizontal movement. Vertical movement shall be motorized and the arm height shall remain at a height greater than 6.5 feet above floor level.
Weight carrying capacity of the arm shall not be less than 180 kg. It shall have electromagnetic/pneumatic brakes.
Each arm shall be capable of minimum 330DEGREE of rotation, which can be easily adjusted to suit the desired mode of operation.
The pendant shall be European CE Certified with 4 digit notified body number/US FDA/ETL/UL/BIS certified/listed under medical devices directive.
The Pendant Service Heads shall be modular with minimum 800mm head.The heads shall be capable of accepting a range of shelves, infusion poles, electrical switch/sockers, gas outlets and other required accessories. The Pendant Heads shall support the range of Physiological Monitor Mounting Solutions.
The Pendant Service Heads shall be supplied with medical gas terminal units and 5A/15A or 6A/16 A hybrid sockets.
Pendant shall be supplied with outlets and probes as mentioned below.
Oxygen Outlets 2 nos , Medical Air Outlets 4 bar .1 no,Vacuum Outlets 2 nos
,Air(7bar) outlets01 no, CO2 outlets01 nos, Electrical Sockets10 no, Adjustable shelf with two rails one on each side 3 no, Data socket RJ45 2 nos, IV Fluid Pole with 2 hooks 1 no, (Pole shall be capable of stacking 4 syringe pumps), Nitrous oxide outlets1 no.
Pendent shall provide cutouts for patch panel in integrated OTs (only for integrated OTs.)
Surgeon pendant shall have NIST connection for all gases to conncet the MGPLS system.
---- etc., complete with all lead | No | 430700.0 | 430700.0 | 1.0 | False | None | None | False | None | False | 430700.0 | 0 | 2964039 | 97974 | None | Approved rate | Scrub Station
MOT SCRUB STATION (minimum size 1500 mm)
supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel (minimum thicknes 1.5 mm) and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.(built in with timer setting from 1 to 10 mic)It shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories.
---- etc., complete with all lead | No | 278480.0 | 278480.0 | 1.0 | False | None | None | False | None | False | 278480.0 | 0 | 2964040 | 97974 | None | Approved rate | Supply , installation, testing and commissioning OT surgical Lighting system with connected accessroies
MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology.
Such lighting system shall have the following technical specifications:
---- etc., complete with all lead | No | 413118.0 | 413118.0 | 1.0 | False | None | None | False | None | False | 413118.0 | 0 | 2964041 | 97974 | None | Approved rate | Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 .45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including SS 304 grade handles.02 sets, SS conceaComplete are all approved The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge ---- etc., complete with all lead | Sqm | 96585.36 | 96585.36 | 3.5 | False | None | None | False | None | False | 338048.76 | 0 | 2964042 | 97974 | None | Approved rate | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade
19 mm thk for supply air duct
---- etc., complete with all lead | Sqm | 1097.4 | 1097.4 | 90.0 | False | None | None | False | None | False | 98766.0 | 0 | 2964043 | 97974 | None | Approved rate | Polishield covering with two coats paint for exposed duct
---- etc., complete with all lead | Sqm | 1038.4 | 1038.4 | 70.0 | False | None | None | False | None | False | 72688.0 | 0 |
| 1709811496000 | 0 | None | None | Buildings | CONSTRUCTION OF 50 BED CRITICAL CARE UNIT HOSPITAL IN THE PREMISES OF WENLOCK HOSPITAL AT MANGALURU, KARNATAKA MGPLS | 10002836.4 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2964044 | 97975 | None | Approved rate | Oxygen Manifold: Main
10+10 Cylinder Oxygen Manifold Should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames Should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 pig.
---- etc., complete with all lead | Set | 128915.0 | 128915.0 | 1.0 | False | None | None | False | None | False | 128915.0 | 0 | 2964045 | 97975 | None | Approved rate | Micro process based Automatic High flow upto 2100 ltrs/min Oxygen Control Panel. 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrator plant 4.1 kg/cm2 (Future Provision) Working Pressure from fully automatic control panel. 4.1 kg/cm2 Working Pressure from Emergency manifold system 4.1 kg/cm2 Changeover unit of all 3 sources Should be at the pressure from oxygen concentrator plant Below 4.1kg/cm2 Changeover unit of all 3 sources Should be at the pressure from main Manifold system Below 4.1kg/cm2 Changeover unit of all 3 sources Should be at the pressure from Emergency manifold system Below 4.1kg/cm2 The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. All the electrical circuits Should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment. The Pannel shall have the necessary instruments, gauges, LED Indicators etc complete with Separate indicators for from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure. Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure. In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure.
---- etc., complete with all lead | No. | 217120.0 | 217120.0 | 1.0 | False | None | None | False | None | False | 217120.0 | 0 | 2964046 | 97975 | None | Approved rate | Oxygen Manifold System Emergency
2+2 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold.Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply.
Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows : Control panel shall be made of M.S.duly powder coated. Easy maintenance.Highly reliable.Designed for safety and continuity of flow supply at a constant pressure.Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure.Capable to provide a distribution flow rate in excess of 1500LPM.Should have Incorporation of safety features in case pressure exceeds 100Psi.
---- etc., complete with all lead | Set | 94990.0 | 94990.0 | 1.0 | False | None | None | False | None | False | 94990.0 | 0 | 2964047 | 97975 | None | Approved rate | Nitrous Oxide Main Manifold System Supply, Installation, Testing and commissioning of 2 cylinder (1 + 1) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
Semi Automatic Nitrous Oxide Main Manifold Control Panel Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
---- etc., complete with all lead | Set | 88500.0 | 88500.0 | 1.0 | False | None | None | False | None | False | 88500.0 | 0 | 2964048 | 97975 | None | Approved rate | Nitrous Oxide Emergency Manifold System Supply, Installation, Testing and commissioning of 1 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
---- etc., complete with all lead | Set | 47200.0 | 47200.0 | 1.0 | False | None | None | False | None | False | 47200.0 | 0 | 2964049 | 97975 | None | Approved rate | Compressed Air System: System For Medical use. Type : Reciprocating, Air cooled oil grease free Capacity of Piston Displacement : 22.93 cfm 649 Lpm Drive : Belt driven No. of Air Compressors : 2 Nos. (1W + 1S by) Motor Capacity : 5 HP as required . Receiver Capacity : 1000 liters water capacity Air reciever Receiver type : Vertical type with inlet, outlet & drain provisions
---- etc., complete with all lead | Set | 800630.0 | 800630.0 | 1.0 | False | None | None | False | None | False | 800630.0 | 0 | 2964050 | 97975 | None | Approved rate | Duplex Medical Air Dryer System ( Breathing Air System) 40 CFM Air Dryer Min Working Pressure should be 4 bar, Rated Inlet Pressure should be 7 bar Max Working Pressure should be 16 bar , Supply Voltage Should be 100-240 VAC, 50/60 Hz, 1 Ph , Rated Inlet temperature should be 38 deg C Dryer capable to give should be 40 PDP , Purge Loss 15% Air quality As per NFPA 99 Dual System, Three stage filter (Dessicated drier) CO & Dew point level as per NFPA 99, Bacterial Penetration 0.00001%, Failure Indication, Purge Saving control Manual, No refrigerant used, Energy saving Dew point based dryer cycling.
---- etc., complete with all lead | No | 88205.0 | 88205.0 | 1.0 | False | None | None | False | None | False | 88205.0 | 0 | 2964051 | 97975 | None | Approved rate | COMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGE The filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3-stages of filters Shouldbe used as mentioned below: Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. Stage 2: Oil aerosol contents removal up to 0.01 mg/cum. Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch .I Standard.
. ---- etc., complete with all lead | Set | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 2964052 | 97975 | None | Approved rate | Air Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz
---- etc., complete with all lead | No | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 2964053 | 97975 | None | Approved rate | The pump installation shall be duplex system consisting of two (1W+1S BY) Identical Rotary Vane Pumps each of which shall be capable of independently producing designed systems flow rate. The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 3276 LPM (200m3/h) i.e., 117 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa). The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system. Pump should be of reputed make as per international standards. The control panel shall consist of three separate Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hour’s run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 1500 Liter or as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust protection.The System should provide audible and visual local and remote alarm indications for the compressor temperature malfunction and reserve compressor in use. All control and alarm functions should remain energized while any compressor remains electrically on-line.
The System should provide manual reset for thermal malfunction shutdown.The lag Pumps should be able to start automatically if the lead compressor fails to operate.
---- etc., complete with all lead | Set | 949900.0 | 949900.0 | 1.0 | False | None | None | False | None | False | 949900.0 | 0 | 2964054 | 97975 | None | Approved rate | Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere. These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005 penetration specified in HTM2022 for infectious disease unit. i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below,Size G1 Bacterial Removal :0.0001 penetration when tested to BS3928
---- etc., complete with all lead | Set | 165200.0 | 165200.0 | 1.0 | False | None | None | False | None | False | 165200.0 | 0 | 2964055 | 97975 | None | Approved rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 42mm. ODx1.2 mm.thick.
---- etc., complete with all lead | m | 3608.44 | 3608.44 | 90.0 | False | None | None | False | None | False | 324759.6 | 0 | 2964056 | 97975 | None | Approved rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 35mm. ODx1.2 mm.thick.
---- etc., complete with all lead | m | 2570.04 | 2570.04 | 180.0 | False | None | None | False | None | False | 462607.2 | 0 | 2964057 | 97975 | None | Approved rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 28mm. ODx0.9 mm.thick.
---- etc., complete with all lead | m | 1492.7 | 1492.7 | 350.0 | False | None | None | False | None | False | 522445.0 | 0 | 2964058 | 97975 | None | Approved rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 22mm. ODx0.9 mm.thick.
---- etc., complete with all lead | m | 1156.4 | 1156.4 | 450.0 | False | None | None | False | None | False | 520380.0 | 0 | 2964059 | 97975 | None | Approved rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 15mm. ODx0.9 mm.thick.
---- etc., complete with all lead | m | 949.9 | 949.9 | 950.0 | False | None | None | False | None | False | 902405.0 | 0 | 2964060 | 97975 | None | Approved rate | Copper Fittings: Supply, Installation, Testing and Commissioning : All copper pipes should be Solid drawn, seamless, deoxidized, non arsenical, half hard, tempered and degreased materials conforming to BS:EN :13348:2001 + A1:2005. Fittings should be made of copper and suitable for a stem of working pressure of 17 bar and Should confirm to BS 864 with specially made for brazed socket type connections.
Copper Pipe 12mm. ODx0.7 mm.thick.
---- etc., complete with all lead | m | 651.36 | 651.36 | 420.0 | False | None | None | False | None | False | 273571.2 | 0 | 2964061 | 97975 | None | Approved rate | Oxygen Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
---- etc., complete with all lead | No | 3392.5 | 3392.5 | 100.0 | False | None | None | False | None | False | 339250.0 | 0 | 2964062 | 97975 | None | Approved rate | Vacuum Terminal - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
---- etc., complete with all lead | No | 3392.5 | 3392.5 | 60.0 | False | None | None | False | None | False | 203550.0 | 0 | 2964063 | 97975 | None | Approved rate | Compressed Air Terminals 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
---- etc., complete with all lead | No | 3392.5 | 3392.5 | 60.0 | False | None | None | False | None | False | 203550.0 | 0 | 2964064 | 97975 | None | Approved rate | Compressed Air Terminals 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
---- etc., complete with all lead | No | 3392.5 | 3392.5 | 7.0 | False | None | None | False | None | False | 23747.5 | 0 | 2964065 | 97975 | None | Approved rate | Nitous Oxide Terminals - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
---- etc., complete with all lead | No | 3392.5 | 3392.5 | 7.0 | False | None | None | False | None | False | 23747.5 | 0 | 2964066 | 97975 | None | Approved rate | ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES.
Oxygen Flow meter with Humidifier Bottle: Flow meter should be Backpressure Compensated. Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute. It should meet strict precision and durability standards. Flow meter body should be made of brass material. Flow tube and shroud components should be made of clear, impact resistant polycarbonate. The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade. The humidifier should have built in safety valve.
---- etc., complete with all lead | No | 2849.7 | 2849.7 | 70.0 | False | None | None | False | None | False | 199479.0 | 0 | 2964067 | 97975 | None | Approved rate | Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps.
---- etc., complete with all lead | No | 3528.2 | 3528.2 | 67.0 | False | None | None | False | None | False | 236389.4 | 0 | 2964068 | 97975 | None | Approved rate | Theatre Vacuum Unit: The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade. Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either. - Left, Right or Both All the above items Should be mounted on a Trolley having a free moving castor wheels.
---- etc., complete with all lead | No | 14750.0 | 14750.0 | 3.0 | False | None | None | False | None | False | 44250.0 | 0 | 2964069 | 97975 | None | Approved rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 42 mm
---- etc., complete with all lead | No | 8142.0 | 8142.0 | 2.0 | False | None | None | False | None | False | 16284.0 | 0 | 2964070 | 97975 | None | Approved rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 35 mm
---- etc., complete with all lead | No | 5428.0 | 5428.0 | 6.0 | False | None | None | False | None | False | 32568.0 | 0 | 2964071 | 97975 | None | Approved rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 28 mm
---- etc., complete with all lead | No | 4071.0 | 4071.0 | 10.0 | False | None | None | False | None | False | 40710.0 | 0 | 2964072 | 97975 | None | Approved rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 22 mm
---- etc., complete with all lead | No | 3392.5 | 3392.5 | 15.0 | False | None | None | False | None | False | 50887.5 | 0 | 2964073 | 97975 | None | Approved rate | ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction
Isolation Valves 15 mm
---- etc., complete with all lead | No | 2714.0 | 2714.0 | 53.0 | False | None | None | False | None | False | 143842.0 | 0 | 2964074 | 97975 | None | Approved rate | Zonal Valve box three Gas services
An Zonal area valve box should have bellow spec.
Wall mounted M.S. box with powder coated & lockable,
front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.
The valve box door cannot be close during valve close position.
---- etc., complete with all lead | No | 18319.5 | 18319.5 | 5.0 | False | None | None | False | None | False | 91597.5 | 0 | 2964075 | 97975 | None | Approved rate | Zonal Valve box five Gas services
An Zonal area valve box should have bellow spec.
Wall mounted M.S. box with powder coated & lockable,
front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.
The valve box door cannot be close during valve close position.
---- etc., complete with all lead | No | 23364.0 | 23364.0 | 4.0 | False | None | None | False | None | False | 93456.0 | 0 | 2964076 | 97975 | None | Approved rate | Digital Area Alarm for Three Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors.
---- etc., complete with all lead | No | 34220.0 | 34220.0 | 5.0 | False | None | None | False | None | False | 171100.0 | 0 | 2964077 | 97975 | None | Approved rate | Digital Area Alarm for Five Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors.
---- etc., complete with all lead | No | 41300.0 | 41300.0 | 4.0 | False | None | None | False | None | False | 165200.0 | 0 | 2964078 | 97975 | None | Approved rate | Bed Headed Panel and Railing. 1.5M Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets. Provision Medical Gas Terminal Units as follows. 2.1 Two oxygen outlet.
2.2 One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar.
---- etc., complete with all lead | No | 31860.0 | 31860.0 | 40.0 | False | None | None | False | None | False | 1274400.0 | 0 | 2964079 | 97975 | None | Approved rate | Surgeon Single Arm Pendant: The material of the Pendent should be Singlearmed rotary ceiling mounted surgical Pendent Highstrength aluminum alloy. Extension arm 700mm. Loading capacity: 70150kg. Level degrees rotation:340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos, Air 4 Bar 01 nos, Air 7 Bar 01 nos, Nitrous Oxide01 nos, Power socket 08 nos, Grounding terminal 01 nos, Platform 03 nos, IV pole 01 nos, Drawer 01 nos
---- etc., complete with all lead | No | 230100.0 | 230100.0 | 2.0 | False | None | None | False | None | False | 460200.0 | 0 | 2964080 | 97975 | None | Approved rate | Anaesthesia Single Arm Pendant: The material of the Pendent should be Singlearmed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70150kg.Level degrees rotation:340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos.
---- etc., complete with all lead | No | 230100.0 | 230100.0 | 2.0 | False | None | None | False | None | False | 460200.0 | 0 |
|
|
---|