2962291 | 97924 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 186.0 | 186.0 | 27.48 | False | None | None | False | None | False | 5111.28 | 0 |
2962292 | 97924 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8 (M5) 40mm nominal size graded crushed coarsed aggrigate & with all lead & lifts and as per direction of the Engineer in charge of work.Mix 1:4:8 (M5) 40mm nominal size graded crushed coarsed aggrigate | Cum | 5206.0 | 5206.0 | 12.94 | False | None | None | False | None | False | 67365.64 | 0 |
2962293 | 97924 | None | code03 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 5198.0 | 5198.0 | 14.5 | False | None | None | False | None | False | 75371.0 | 0 |
2962294 | 97924 | None | code04 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 200.0 | 200.0 | 11.65 | False | None | None | False | None | False | 2330.0 | 0 |
2962295 | 97924 | None | code05 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 122.0 | 122.0 | 35.1 | False | None | None | False | None | False | 4282.2 | 0 |
2962296 | 97924 | None | code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. For column Footings (The cost of steel reinforcement, dowel bars & including formmwork M20 design mix using 20 mm nominal size graded crushed coarsed aggrigate & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 6676.56 | 6676.56 | 1.66 | False | None | None | False | None | False | 11083.0896 | 0 |
2962297 | 97924 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications For Columns . (The cost of steel reinforcement, dowel bars & including formmwork M20 design mix using 20 mm nominal size graded crushed coarsed aggrigate & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 10509.4 | 10509.4 | 1.27 | False | None | None | False | None | False | 13346.938 | 0 |
2962298 | 97924 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.For Plinth(The cost of steel reinforcement, dowel bars & including formmwork M20 design mix using 20 mm nominal size graded crushed coarsed aggrigate & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 9273.0 | 9273.0 | 2.56 | False | None | None | False | None | False | 23738.88 | 0 |
2962299 | 97924 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specificationsFor .Lintel (The cost of steel reinforcement, dowel bars & including formmwork M20 design mix using 20 mm nominal size graded crushed coarsed aggrigate & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 9891.2 | 9891.2 | 6.39 | False | None | None | False | None | False | 63204.768 | 0 |
2962300 | 97924 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. For Roof(The cost of steel reinforcement, dowel bars & including formmwork M20 design mix using 20 mm nominal size graded crushed coarsed aggrigate & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 9273.0 | 9273.0 | 10.84 | False | None | None | False | None | False | 100519.32 | 0 |
2962301 | 97924 | None | code11 | Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (Thelaps and wastages shall not be measured separately) & with all lead and lift. and as per direction of the Engineer in charge of work. | Kg | 92.0 | 92.0 | 1590.48 | False | None | None | False | None | False | 146324.16 | 0 |
2962302 | 97924 | None | code12 | Providing Brick work with common burnt clay modular bricks of class designation 5.0 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 8860.0 | 8860.0 | 24.85 | False | None | None | False | None | False | 220171.0 | 0 |
2962303 | 97924 | None | code13 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. & with all lead & lifts and as per direction of the Engineer in charge of work. | Cum | 75344.0 | 75344.0 | 0.15 | False | None | None | False | None | False | 11301.6 | 0 |
2962304 | 97924 | None | code14 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 4556.0 | 4556.0 | 2.4 | False | None | None | False | None | False | 10934.4 | 0 |
2962305 | 97924 | None | code15 | Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 4625.0 | 4625.0 | 5.4 | False | None | None | False | None | False | 24975.0 | 0 |
2962306 | 97924 | None | code16 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 213.0 | 213.0 | 181.2 | False | None | None | False | None | False | 38595.6 | 0 |
2962307 | 97924 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 230.0 | 230.0 | 139.825 | False | None | None | False | None | False | 32159.75 | 0 |
2962308 | 97924 | None | code18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 1087.0 | 1087.0 | 85.8 | False | None | None | False | None | False | 93264.6 | 0 |
2962309 | 97924 | None | code19 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 105.0 | 105.0 | 181.2 | False | None | None | False | None | False | 19026.0 | 0 |
2962310 | 97924 | None | code20 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 66.0 | 66.0 | 139.82 | False | None | None | False | None | False | 9228.12 | 0 |
2962311 | 97924 | None | code21 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One coats on old work as per specifications and as per directions of Engineer in charge. & with all lead & lifts and as per direction of the Engineer in charge of work. | Sqm | 59.0 | 59.0 | 17.55 | False | None | None | False | None | False | 1035.45 | 0 |
2962312 | 97924 | None | code22 | KSRB15-3.12 Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to
brick/stone masonary including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost
of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge | Sqm | 276.0 | 276.0 | 78.0 | False | None | None | False | None | False | 21528.0 | 0 |
2962313 | 97924 | None | code23 | Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick & with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 50.0 | 50.0 | 40.0 | False | None | None | False | None | False | 2000.0 | 0 |
2962314 | 97924 | None | code24 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Short point upto 3Mtr from tapping point to out let via switch box & with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 160.0 | 160.0 | 2.0 | False | None | None | False | None | False | 320.0 | 0 |
2962315 | 97924 | None | code25 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box & with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 250.0 | 250.0 | 2.0 | False | None | None | False | None | False | 500.0 | 0 |
2962316 | 97924 | None | code26 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet..Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box & with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 375.0 | 375.0 | 2.0 | False | None | None | False | None | False | 750.0 | 0 |
2962317 | 97924 | None | code27 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 sqmm & with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 20.5 | 20.5 | 70.0 | False | None | None | False | None | False | 1435.0 | 0 |
2962318 | 97924 | None | code28 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm & with all lead & lifts and as per direction of the Engineer in charge of work. | Mtr | 32.0 | 32.0 | 40.0 | False | None | None | False | None | False | 1280.0 | 0 |
2962319 | 97924 | None | code29 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-3Way & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 85.0 | 85.0 | 2.0 | False | None | None | False | None | False | 170.0 | 0 |
2962320 | 97924 | None | code30 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 115.0 | 115.0 | 2.0 | False | None | None | False | None | False | 230.0 | 0 |
2962321 | 97924 | None | code31 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. 1 to 3 Module & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 110.0 | 110.0 | 2.0 | False | None | None | False | None | False | 220.0 | 0 |
2962322 | 97924 | None | code32 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.. 1 to 3 Module & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
2962323 | 97924 | None | code33 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 434.0 | 434.0 | 1.0 | False | None | None | False | None | False | 434.0 | 0 |
2962324 | 97924 | None | code34 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 0.4 | 0.4 | 2500.0 | False | None | None | False | None | False | 1000.0 | 0 |
2962325 | 97924 | None | code35 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 70.0 | 70.0 | 10.0 | False | None | None | False | None | False | 700.0 | 0 |
2962326 | 97924 | None | code36 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 105.0 | 105.0 | 2.0 | False | None | None | False | None | False | 210.0 | 0 |
2962327 | 97924 | None | code37 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 290.0 | 290.0 | 2.0 | False | None | None | False | None | False | 580.0 | 0 |
2962328 | 97924 | None | code38 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter. & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 1150.0 | 1150.0 | 1.0 | False | None | None | False | None | False | 1150.0 | 0 |
2962329 | 97924 | None | code39 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1KV 40mm & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 335.0 | 335.0 | 2.0 | False | None | None | False | None | False | 670.0 | 0 |
2962330 | 97924 | None | code40 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia 48" Sweep (1200mm) Regular model & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 2999.7 | 2999.7 | 1.0 | False | None | None | False | None | False | 2999.7 | 0 |
2962331 | 97924 | None | code41 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 2090.0 | 2090.0 | 2.0 | False | None | None | False | None | False | 4180.0 | 0 |
2962332 | 97924 | None | code42 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4'- 20/22 w & with all lead & lifts and as per direction of the Engineer in charge of work. | No | 375.0 | 375.0 | 6.0 | False | None | None | False | None | False | 2250.0 | 0 |