| 2960655 | 97875 | None | CODE1 | CIVIL WORKS Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 1.5m as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. : In all kinds of soils Upto 1.5m depth | Cum | 116.58 | 116.58 | 11430.0 | False | None | None | False | None | False | 1332509.4 | 0 |
| 2960656 | 97875 | None | CODE2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work
In all kinds of soils Depth upto 3 m | Cum | 125.17 | 125.17 | 11768.0 | False | None | None | False | None | False | 1473000.56 | 0 |
| 2960657 | 97875 | None | CODE3 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 326.44 | 326.44 | 23018.0 | False | None | None | False | None | False | 7513995.92 | 0 |
| 2960658 | 97875 | None | CODE4 | Earthwork excavation ( in deposited soil ) and filling sides of foundation upto plinth in layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming after watering with lead upto 50m. and lift upto 1.5 m. including cost of all labour complete as per pecifications.specification. | Cum | 552.61 | 552.61 | 9995.0 | False | None | None | False | None | False | 5523336.95 | 0 |
| 2960659 | 97875 | None | CODE5 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with alllifts and lead, transportation to site, spreading, grading to required slope andcompacting to meet the requirement complete as per specifications, includingcost of labour,rolling,water,all materials,usage& all other appurtenaces requiredto complete the work. | Cum | 581.69 | 581.69 | 2214.0 | False | None | None | False | None | False | 1287861.66 | 0 |
| 2960660 | 97875 | None | CODE6 | Construction of Granular Sub-Base by Mix in Place Method by providing well graded Gravel, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density complete as per Technical Spec | Cum | 2894.96 | 2894.96 | 893.0 | False | None | None | False | None | False | 2585199.28 | 0 |
| 2960661 | 97875 | None | CODE7 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with lead and lift complete as per specifications. | Cum | 3291.35 | 3291.35 | 2597.0 | False | None | None | False | None | False | 8547635.95 | 0 |
| 2960662 | 97875 | None | CODE8 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired densit | Cum | 3140.4 | 3140.4 | 893.0 | False | None | None | False | None | False | 2804377.2 | 0 |
| 2960663 | 97875 | None | CODE9 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conformingto IS: 383, the size of coarse aggregate not exceeding 25 mm,aggregate cement ratio not to exceed 14:1, aggregate gradationafter blNoing to be as per table 600-1, cement content not to beless than 140 kg/cum , optimum moisture content to be determinedduring trial length construction, concrete strength not to be lessthan 7 Mpa at 7 days, mixed in a batching plant, transported tosite, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing | Cum | 6037.82 | 6037.82 | 595.0 | False | None | None | False | None | False | 3592502.9 | 0 |
| 2960664 | 97875 | None | CODE10 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately)
Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6950.86 | 6950.86 | 1976.0 | False | None | None | False | None | False | 13734899.36 | 0 |
| 2960665 | 97875 | None | CODE11 | Providing and laying in position Reinforced/ Plain cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately) Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates 0.00m to 3.50m Level | Cum | 8487.71 | 8487.71 | 40.0 | False | None | None | False | None | False | 339508.4 | 0 |
| 2960666 | 97875 | None | CODE12 | Above 3.50m to 7.00m Level | Cum | 8572.58 | 8572.58 | 3.0 | False | None | None | False | None | False | 25717.74 | 0 |
| 2960667 | 97875 | None | CODE13 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
'--do-- for Column Footings / Retaining Wall Footings / Raft / Base Slab | Cum | 8332.64 | 8332.64 | 2766.0 | False | None | None | False | None | False | 23048082.24 | 0 |
| 2960668 | 97875 | None | CODE14 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately)
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
--do-- for Plinth Beam with M-25 | Cum | 11928.38 | 11928.38 | 582.0 | False | None | None | False | None | False | 6942317.16 | 0 |
| 2960669 | 97875 | None | CODE15 | do for RCC Wall with M-25 | Cum | 10735.55 | 10735.55 | 87.0 | False | None | None | False | None | False | 933992.85 | 0 |
| 2960670 | 97875 | None | CODE16 | do for RCC Gutter with M25 | Cum | 11530.77 | 11530.77 | 108.0 | False | None | None | False | None | False | 1245323.16 | 0 |
| 2960671 | 97875 | None | CODE17 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -For RCC Raft | Cum | 8613.62 | 8613.62 | 17.0 | False | None | None | False | None | False | 146431.54 | 0 |
| 2960672 | 97875 | None | CODE18 | DO for RCC Wall with M-30 | Cum | 10942.64 | 10942.64 | 17.0 | False | None | None | False | None | False | 186024.88 | 0 |
| 2960673 | 97875 | None | CODE19 | do-- for RCC Slab with M-30 | Cum | 12898.49 | 12898.49 | 8.0 | False | None | None | False | None | False | 103187.92 | 0 |
| 2960674 | 97875 | None | CODE20 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications including cost of formwork. (The cost of steel reinforcement shall be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates -'--do-- for Columns / Pedestals with M-25.
0.00m to 3.50m Level | Cum | 14276.14 | 14276.14 | 605.0 | False | None | None | False | None | False | 8637064.7 | 0 |
| 2960675 | 97875 | None | CODE21 | Above 3.50m to 7.00m Level | Cum | 14418.9 | 14418.9 | 67.0 | False | None | None | False | None | False | 966066.3 | 0 |
| 2960676 | 97875 | None | CODE22 | Above 7.00m to 10.50m Level | Cum | 14561.66 | 14561.66 | 4.0 | False | None | None | False | None | False | 58246.64 | 0 |
| 2960677 | 97875 | None | CODE23 | do-- for Lintel / Tie Beam with M-25
0.00m to 3.50m Level | Cum | 13436.37 | 13436.37 | 64.0 | False | None | None | False | None | False | 859927.68 | 0 |
| 2960678 | 97875 | None | CODE24 | Above 3.50m to 7.00m Level | Cum | 13570.73 | 13570.73 | 8.0 | False | None | None | False | None | False | 108565.84 | 0 |
| 2960679 | 97875 | None | CODE25 | do-- for Staircase with M-25
0.00m to 3.50m Level | Cum | 12596.59 | 12596.59 | 9.0 | False | None | None | False | None | False | 113369.31 | 0 |
| 2960680 | 97875 | None | CODE26 | Above 3.50m to 7.00m Level | Cum | 12722.56 | 12722.56 | 6.0 | False | None | None | False | None | False | 76335.36 | 0 |
| 2960681 | 97875 | None | CODE27 | do-- for Roof Beams with M-25
0.00m to 3.50m Level | Cum | 13436.37 | 13436.37 | 77.0 | False | None | None | False | None | False | 1034600.49 | 0 |
| 2960682 | 97875 | None | CODE28 | Above 3.50m to 7.00m Level | Cum | 13570.73 | 13570.73 | 176.0 | False | None | None | False | None | False | 2388448.48 | 0 |
| 2960683 | 97875 | None | CODE29 | Above 7.00m to 10.50m Level | Cum | 13705.09 | 13705.09 | 3.0 | False | None | None | False | None | False | 41115.27 | 0 |
| 2960684 | 97875 | None | CODE30 | do-- for Roof Slabs with M-25
0.00m to 3.50m Level | Cum | 12596.59 | 12596.59 | 131.0 | False | None | None | False | None | False | 1650153.29 | 0 |
| 2960685 | 97875 | None | CODE31 | Above 3.50m to 7.00m Level | Cum | 12722.56 | 12722.56 | 172.0 | False | None | None | False | None | False | 2188280.32 | 0 |
| 2960686 | 97875 | None | CODE32 | Do-- for Chejja with M-25.
0.00m to 3.50m Level | Cum | 12176.71 | 12176.71 | 36.0 | False | None | None | False | None | False | 438361.56 | 0 |
| 2960687 | 97875 | None | CODE33 | Above 3.50m to 7.00m Level | Cum | 12298.47 | 12298.47 | 3.0 | False | None | None | False | None | False | 36895.41 | 0 |
| 2960688 | 97875 | None | CODE34 | Above 7.00m to 10.50m Level | Cum | 12420.24 | 12420.24 | 1.0 | False | None | None | False | None | False | 12420.24 | 0 |
| 2960689 | 97875 | None | CODE35 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications.
0.00m to 3.50m Level | Sqm | 1519.27 | 1519.27 | 111.0 | False | None | None | False | None | False | 168638.97 | 0 |
| 2960690 | 97875 | None | CODE36 | Above 3.50m to 7.00m Level | Sqm | 1534.47 | 1534.47 | 14.0 | False | None | None | False | None | False | 21482.58 | 0 |
| 2960691 | 97875 | None | CODE37 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bNoing, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)
0.00m to 3.50m Level | MT | 109781.63 | 109781.63 | 552.0 | False | None | None | False | None | False | 60599459.76 | 0 |
| 2960692 | 97875 | None | CODE38 | Above 3.50m to 7.00m Level | MT | 110879.45 | 110879.45 | 67.0 | False | None | None | False | None | False | 7428923.15 | 0 |
| 2960693 | 97875 | None | CODE39 | Above 7.00m to 10.50m Level | MT | 111977.26 | 111977.26 | 2.0 | False | None | None | False | None | False | 223954.52 | 0 |
| 2960694 | 97875 | None | CODE40 | Providing and constructing granite / trap / basalt size stone masonry with hard stone in foundation & plinth in cement mortar 1:6, stones in courses not less than 20 cms high, bond stones at two m. apart in each course including cost of materials, labour, curing complete as per specifications. | Cum | 7840.58 | 7840.58 | 79.0 | False | None | None | False | None | False | 619405.82 | 0 |
| 2960695 | 97875 | None | CODE41 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
0.00m to 3.50m Level | Sqm | 1607.63 | 1607.63 | 4531.0 | False | None | None | False | None | False | 7284171.53 | 0 |
| 2960696 | 97875 | None | CODE42 | Above 3.50m to 7.00m Level | Sqm | 1623.71 | 1623.71 | 1511.0 | False | None | None | False | None | False | 2453425.81 | 0 |
| 2960697 | 97875 | None | CODE43 | Above 7.00m to 10.50m Level | Sqm | 1639.78 | 1639.78 | 101.0 | False | None | None | False | None | False | 165617.78 | 0 |
| 2960698 | 97875 | None | CODE44 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x100mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of allmaterials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.
0.00m to 3.50m Level | Sqm | 1354.83 | 1354.83 | 223.0 | False | None | None | False | None | False | 302127.09 | 0 |
| 2960699 | 97875 | None | CODE45 | Above 3.50m to 7.00m Level | Sqm | 1368.38 | 1368.38 | 196.0 | False | None | None | False | None | False | 268202.48 | 0 |
| 2960700 | 97875 | None | CODE46 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62 x 125mm
0.00m to 3.50m Level | Mtr | 937.58 | 937.58 | 107.0 | False | None | None | False | None | False | 100321.06 | 0 |
| 2960701 | 97875 | None | CODE47 | Above 3.50m to 7.00m Level | Mtr | 946.96 | 946.96 | 81.0 | False | None | None | False | None | False | 76703.76 | 0 |
| 2960702 | 97875 | None | CODE48 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquidphenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.
-do- 35 mm thick both side Teak
0.00m to 3.50m Level | Sqm | 7402.47 | 7402.47 | 34.0 | False | None | None | False | None | False | 251683.98 | 0 |
| 2960703 | 97875 | None | CODE49 | Above 3.50m to 7.00m Level | Sqm | 7476.5 | 7476.5 | 22.0 | False | None | None | False | None | False | 164483.0 | 0 |
| 2960704 | 97875 | None | CODE50 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.
0.00m to 3.50m Level | Mtr | 390.25 | 390.25 | 65.0 | False | None | None | False | None | False | 25366.25 | 0 |
| 2960705 | 97875 | None | CODE51 | Above 3.50m to 7.00m Level | Mtr | 394.15 | 394.15 | 65.0 | False | None | None | False | None | False | 25619.75 | 0 |
| 2960706 | 97875 | None | CODE52 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 No of 75mm Aluminium hinges. -do- with both side prelam :
0.00m to 3.50m Level | Sqm | 3517.16 | 3517.16 | 21.0 | False | None | None | False | None | False | 73860.36 | 0 |
| 2960707 | 97875 | None | CODE53 | Above 3.50m to 7.00m Level | Sqm | 3552.33 | 3552.33 | 21.0 | False | None | None | False | None | False | 74598.93 | 0 |
| 2960708 | 97875 | None | CODE54 | Supply & Fixing of Powder Coated Mild Steel doors, frames & shutters made of Skin pass galvanized Iron sheet conforming to Base Steel as per IS 513 D Quality, Galvanized as per IS 277 with Hot Zinc Coating of 120 grams/ Sq.Mtr with powder coating of thickness 60-65 Microns, frame with 1.2mm thick Skin pass Galvanized Iron sheet formed to single rebate profile of ize 100 mm X 58 mm and filled with in-fill Polyurethane foam, the Door Shutters are with 0.80 mm thick Skin pass Galvanized Iron Sheet formed to provide a 46 mm thick fully flush, double skin door shell with Lock Seam joints at stile edges, fitted with in-fill of Honeycomb Kraft Paper and coated with polyester powders of Pure polyester/ epoxy polyester or polyurethane powder for powder coating of thickness 60 65 microns and are coated with Zinc Phosphate Primer to receive any paint on site or finished with Thermosetting Polyurethane paint of Aliphatic Grade providing high levels of scratch resistance and durability, the Shutter provided with 6 MM clear float vision glass in Circular, Square or Rectangular shapes, Stainless Steel Ball Bearing Butt Hinges 3 mm thick fixed flush to the frame and shutter (Profile 102x76x3mm thick).Mortise Sash Lock with Lever Handles, Mortise Dead Bolt, etc for industrial, commercial, residential, cleanroom applications. 0.00m to 3.50m Level | Sqm | 11682.0 | 11682.0 | 107.0 | False | None | None | False | None | False | 1249974.0 | 0 |
| 2960709 | 97875 | None | CODE55 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.
0.00m to 3.50m Level | Kgs | 700.73 | 700.73 | 3988.0 | False | None | None | False | None | False | 2794511.24 | 0 |
| 2960710 | 97875 | None | CODE56 | Above 3.50m to 7.00m Level | Kgs | 707.74 | 707.74 | 1027.0 | False | None | None | False | None | False | 726848.98 | 0 |
| 2960711 | 97875 | None | CODE57 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) : With float glass panes of 5mm thickness (weight not less than 12.50kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
0.00m to 3.50m Level | Sqm | 1437.05 | 1437.05 | 528.0 | False | None | None | False | None | False | 758762.4 | 0 |
| 2960712 | 97875 | None | CODE58 | Above 3.50m to 7.00m Level | Sqm | 1451.42 | 1451.42 | 137.0 | False | None | None | False | None | False | 198844.54 | 0 |
| 2960713 | 97875 | None | CODE59 | Providing & fixing SS fly proof wire gauze to windows, clerestory windows & doors to exsisting aluminium frame. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
0.00m to 3.50m Level | Sqm | 1057.85 | 1057.85 | 264.0 | False | None | None | False | None | False | 279272.4 | 0 |
| 2960714 | 97875 | None | CODE60 | Above 3.50m to 7.00m Level | Sqm | 1068.42 | 1068.42 | 69.0 | False | None | None | False | None | False | 73720.98 | 0 |
| 2960715 | 97875 | None | CODE61 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding / Aluminium Windows with Holdfast embeded in masonry
0.00m to 3.50m Level | Kgs | 206.17 | 206.17 | 9074.0 | False | None | None | False | None | False | 1870786.58 | 0 |
| 2960716 | 97875 | None | CODE62 | Above 3.50m to 7.00m Level | Kgs | 208.23 | 208.23 | 1093.0 | False | None | None | False | None | False | 227595.39 | 0 |
| 2960717 | 97875 | None | CODE63 | Providing and fixing Stainless steel staircase railing as per Chief Architect Drawing No. 11520/HRSC with hand rail 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 5 No of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges etc., complete as per specification.
0.00m to 3.50m Level | Kgs | 693.37 | 693.37 | 298.0 | False | None | None | False | None | False | 206624.26 | 0 |
| 2960718 | 97875 | None | CODE64 | Above 3.50m to 7.00m Level | Kgs | 700.3 | 700.3 | 186.0 | False | None | None | False | None | False | 130255.8 | 0 |
| 2960719 | 97875 | None | CODE65 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the No by No locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 3231.22 | 3231.22 | 204.0 | False | None | None | False | None | False | 659168.88 | 0 |
| 2960720 | 97875 | None | CODE66 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linearas well as curvilinear portions of the building by providing semi -rigid,inorganic, non-combustible fibre glass wool insulation 50 mm thick, conformingto IS: 8183 and BS: 3958 Part 5. The insulation layer shall havefacing (factory bonded on surface 1 of the fibre glass insulation layer),of black non-woven fibre glass tissue of nominal thickness 0.5 mm andnominal mass not less than60 g/m2,made of randomly oriented glassfibres distributed in a binder by a wet-lay process including fixing 1.5mm thick solid aluminum sheet backing using, 6 mm thick cement boardincluding SS rivets, nuts, bolts, washers etc complete.
0.00m to 3.50m Level | Sqm | 2379.54 | 2379.54 | 15.0 | False | None | None | False | None | False | 35693.1 | 0 |
| 2960721 | 97875 | None | CODE67 | Above 3.50m to 7.00m Level | Sqm | 2403.34 | 2403.34 | 40.0 | False | None | None | False | None | False | 96133.6 | 0 |
| 2960722 | 97875 | None | CODE68 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary For Straight Portion | Sqm | 4895.3 | 4895.3 | 15.0 | False | None | None | False | None | False | 73429.5 | 0 |
| 2960723 | 97875 | None | CODE69 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 7635.64 | 7635.64 | 5.0 | False | None | None | False | None | False | 38178.2 | 0 |
| 2960724 | 97875 | None | CODE70 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to Ceiling / Concrete / brick masonry including rounding off corners wherever required smooth rNoering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 0.00m to 3.50m Level | Sqm | 396.39 | 396.39 | 989.0 | False | None | None | False | None | False | 392029.71 | 0 |
| 2960725 | 97875 | None | CODE71 | Above 3.50m to 7.00m Level | Sqm | 400.35 | 400.35 | 1045.0 | False | None | None | False | None | False | 418365.75 | 0 |
| 2960726 | 97875 | None | CODE72 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rNoering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 0.00m to 3.50m Level | Sqm | 428.29 | 428.29 | 5003.0 | False | None | None | False | None | False | 2142734.87 | 0 |
| 2960727 | 97875 | None | CODE73 | Above 3.50m to 7.00m Level | Sqm | 432.58 | 432.58 | 2106.0 | False | None | None | False | None | False | 911013.48 | 0 |
| 2960728 | 97875 | None | CODE74 | Above 7.00m to 10.50m Level | Sqm | 436.86 | 436.86 | 50.0 | False | None | None | False | None | False | 21843.0 | 0 |
| 2960729 | 97875 | None | CODE75 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rNoering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. 0.00m to 3.50m Level | Sqm | 472.47 | 472.47 | 8672.0 | False | None | None | False | None | False | 4097259.84 | 0 |
| 2960730 | 97875 | None | CODE76 | Above 3.50m to 7.00m Level | Sqm | 477.2 | 477.2 | 1554.0 | False | None | None | False | None | False | 741568.8 | 0 |
| 2960731 | 97875 | None | CODE77 | Above 7.00m to 10.50m Level | Sqm | 481.92 | 481.92 | 172.0 | False | None | None | False | None | False | 82890.24 | 0 |
| 2960732 | 97875 | None | CODE78 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rNoering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. with providing and mixing water proofing material in cement plaster work in proportion recommNoed by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer- in-Charge.
0.00m to 3.50m Level | Sqm | 546.1 | 546.1 | 302.0 | False | None | None | False | None | False | 164922.2 | 0 |
| 2960733 | 97875 | None | CODE79 | Above 3.50m to 7.00m Level | Sqm | 551.57 | 551.57 | 192.0 | False | None | None | False | None | False | 105901.44 | 0 |
| 2960734 | 97875 | None | CODE80 | Above 7.00m to 10.50m Level | Sqm | 557.03 | 557.03 | 163.0 | False | None | None | False | None | False | 90795.89 | 0 |
| 2960735 | 97875 | None | CODE81 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth.
0.00m to 3.50m Level | Mtr | 81.0 | 81.0 | 3059.0 | False | None | None | False | None | False | 247779.0 | 0 |
| 2960736 | 97875 | None | CODE82 | Above 3.50m to 7.00m Level | Mtr | 81.81 | 81.81 | 81.0 | False | None | None | False | None | False | 6626.61 | 0 |
| 2960737 | 97875 | None | CODE83 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.
0.00m to 3.50m Level | Sqm | 3499.97 | 3499.97 | 160.0 | False | None | None | False | None | False | 559995.2 | 0 |
| 2960738 | 97875 | None | CODE84 | Providing and laying flamed / Sand Blasted finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 30 mm thick stone slab over 25 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. | Sqm | 4085.47 | 4085.47 | 80.0 | False | None | None | False | None | False | 326837.6 | 0 |
| 2960739 | 97875 | None | CODE85 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2
0.00m to 3.50m Level | Sqm | 4831.49 | 4831.49 | 31.0 | False | None | None | False | None | False | 149776.19 | 0 |
| 2960740 | 97875 | None | CODE86 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.
0.00m to 3.50m Level | Sqm | 6538.52 | 6538.52 | 93.0 | False | None | None | False | None | False | 608082.36 | 0 |
| 2960741 | 97875 | None | CODE87 | Above 3.50m to 7.00m Level | Sqm | 6603.91 | 6603.91 | 51.0 | False | None | None | False | None | False | 336799.41 | 0 |
| 2960742 | 97875 | None | CODE88 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.
0.00m to 3.50m Level | Mtr | 402.52 | 402.52 | 224.0 | False | None | None | False | None | False | 90164.48 | 0 |
| 2960743 | 97875 | None | CODE89 | Above 3.50m to 7.00m Level | Mtr | 406.55 | 406.55 | 74.0 | False | None | None | False | None | False | 30084.7 | 0 |
| 2960744 | 97875 | None | CODE90 | Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. | Sqm | 4122.16 | 4122.16 | 25.0 | False | None | None | False | None | False | 103054.0 | 0 |
| 2960745 | 97875 | None | CODE91 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
0.00m to 3.50m Level | Sqm | 1405.14 | 1405.14 | 370.0 | False | None | None | False | None | False | 519901.8 | 0 |
| 2960746 | 97875 | None | CODE92 | Above 3.50m to 7.00m Level | Sqm | 1419.2 | 1419.2 | 359.0 | False | None | None | False | None | False | 509492.8 | 0 |
| 2960747 | 97875 | None | CODE93 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting / dadoing, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge
0.00m to 3.50m Level | Sqm | 1439.51 | 1439.51 | 277.0 | False | None | None | False | None | False | 398744.27 | 0 |
| 2960748 | 97875 | None | CODE94 | Above 3.50m to 7.00m Level | Sqm | 1453.9 | 1453.9 | 116.0 | False | None | None | False | None | False | 168652.4 | 0 |
| 2960749 | 97875 | None | CODE95 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.
0.00m to 3.50m Level | Sqm | 1357.28 | 1357.28 | 48.0 | False | None | None | False | None | False | 65149.44 | 0 |
| 2960750 | 97875 | None | CODE96 | Above 3.50m to 7.00m Level | Sqm | 1370.86 | 1370.86 | 48.0 | False | None | None | False | None | False | 65801.28 | 0 |
| 2960751 | 97875 | None | CODE97 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.
0.00m to 3.50m Level | Sqm | 1357.28 | 1357.28 | 245.0 | False | None | None | False | None | False | 332533.6 | 0 |
| 2960752 | 97875 | None | CODE98 | Above 3.50m to 7.00m Level | Sqm | 1370.86 | 1370.86 | 245.0 | False | None | None | False | None | False | 335860.7 | 0 |
| 2960753 | 97875 | None | CODE99 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M20 (Grade), coarse and fine aggregates conforming to IS:383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 7822.17 | 7822.17 | 1924.0 | False | None | None | False | None | False | 15049855.08 | 0 |
| 2960754 | 97875 | None | CODE100 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383:2016:, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick olythene film, wedges, steel plates including levelling the ormwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. | Cum | 8288.51 | 8288.51 | 1190.0 | False | None | None | False | None | False | 9863326.9 | 0 |
| 2960755 | 97875 | None | CODE101 | Vaccum de-watering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift with laser levelling | Sqm | 104.31 | 104.31 | 12958.0 | False | None | None | False | None | False | 1351648.98 | 0 |
| 2960756 | 97875 | None | CODE102 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge | Mtr | 85.9 | 85.9 | 5735.0 | False | None | None | False | None | False | 492636.5 | 0 |
| 2960757 | 97875 | None | CODE103 | Providing to contraction joints polysuphide sealent (Pouring grade) confirming to BS : 5212 - 1989 into sawed groove widened at top for sealent reservoir of specified size and shape as per detailed drawing including fixing Polyethylene foam backer rod of required diameter (approx. 25% larger than the initial 3 mm.to 4 mm. joint) overlaid with bond breaking tape as per detailed drawing. Item includes cleaning the joints with water jet / air compressor and allowing joint to become thoroughly dry before sealent is applied and applying primer. (A) Contraction and longitudinal joints (15 mm. deep x 8 mm.wide). | Mtr | 202.49 | 202.49 | 5735.0 | False | None | None | False | None | False | 1161280.15 | 0 |
| 2960758 | 97875 | None | CODE104 | Grinding, densification & polishing the concrete surface in 12 stages grind with metal pads 60 120, polish with resin pads 50 100 200 400 800 1500 3000, apply a coat of Lithium Silicate Densifier (approved make), apply a coat of Acylic Sealer (approved make), burnishing after application after application of sealer to achieve dustproof, abrasion resistant and high gloss surface. | Sqm | 295.0 | 295.0 | 12958.0 | False | None | None | False | None | False | 3822610.0 | 0 |
| 2960759 | 97875 | None | CODE105 | Providing & adding approved make Floor Hardner in flooring as per details. | Kgs | 29.5 | 29.5 | 90699.0 | False | None | None | False | None | False | 2675620.5 | 0 |
| 2960760 | 97875 | None | CODE106 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 981.76 | 981.76 | 41.0 | False | None | None | False | None | False | 40252.16 | 0 |
| 2960761 | 97875 | None | CODE107 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)
Medium shade pigment using 50% white cement 50% Grey cement | Sqm | 1462.82 | 1462.82 | 50.0 | False | None | None | False | None | False | 73141.0 | 0 |
| 2960762 | 97875 | None | CODE108 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
0.00m to 3.50m Level | Sqm | 122.72 | 122.72 | 5259.0 | False | None | None | False | None | False | 645384.48 | 0 |
| 2960763 | 97875 | None | CODE109 | Above 3.50m to 7.00m Level | Sqm | 123.95 | 123.95 | 2455.0 | False | None | None | False | None | False | 304297.25 | 0 |
| 2960764 | 97875 | None | CODE110 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directionsof Engineer-in-charge.
0.00m to 3.50m Level | Sqm | 168.13 | 168.13 | 573.0 | False | None | None | False | None | False | 96338.49 | 0 |
| 2960765 | 97875 | None | CODE111 | Above 3.50m to 7.00m Level | Sqm | 169.81 | 169.81 | 696.0 | False | None | None | False | None | False | 118187.76 | 0 |
| 2960766 | 97875 | None | CODE112 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.50m Level | Sqm | 193.9 | 193.9 | 5259.0 | False | None | None | False | None | False | 1019720.1 | 0 |
| 2960767 | 97875 | None | CODE113 | Above 3.50m to 7.00m Level | Sqm | 195.84 | 195.84 | 2455.0 | False | None | None | False | None | False | 480787.2 | 0 |
| 2960768 | 97875 | None | CODE114 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.50m Level | Sqm | 191.44 | 191.44 | 8674.0 | False | None | None | False | None | False | 1660550.56 | 0 |
| 2960769 | 97875 | None | CODE115 | Above 3.50m to 7.00m Level | Sqm | 193.36 | 193.36 | 1556.0 | False | None | None | False | None | False | 300868.16 | 0 |
| 2960770 | 97875 | None | CODE116 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 347.3 | 347.3 | 56.0 | False | None | None | False | None | False | 19448.8 | 0 |
| 2960771 | 97875 | None | CODE117 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.50m Level | Sqm | 169.35 | 169.35 | 398.0 | False | None | None | False | None | False | 67401.3 | 0 |
| 2960772 | 97875 | None | CODE118 | Above 3.50m to 7.00m Level | Sqm | 171.05 | 171.05 | 30.0 | False | None | None | False | None | False | 5131.5 | 0 |
| 2960773 | 97875 | None | CODE119 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
0.00m to 3.50m Level | Sqm | 170.58 | 170.58 | 691.0 | False | None | None | False | None | False | 117870.78 | 0 |
| 2960774 | 97875 | None | CODE120 | Above 3.50m to 7.00m Level | Sqm | 172.29 | 172.29 | 27.0 | False | None | None | False | None | False | 4651.83 | 0 |
| 2960775 | 97875 | None | CODE121 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including joining with seal ring conforming to to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter
0.00m to 3.50m Level | Mtr | 357.12 | 357.12 | 1263.0 | False | None | None | False | None | False | 451042.56 | 0 |
| 2960776 | 97875 | None | CODE122 | Above 3.50m to 7.00m Level | Mtr | 360.69 | 360.69 | 80.0 | False | None | None | False | None | False | 28855.2 | 0 |
| 2960777 | 97875 | None | CODE123 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amNoments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labor with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.
0.00m to 3.50m Level | Mtr | 504.38 | 504.38 | 550.0 | False | None | None | False | None | False | 277409.0 | 0 |
| 2960778 | 97875 | None | CODE124 | Above 3.50m to 7.00m Level | Mtr | 509.42 | 509.42 | 550.0 | False | None | None | False | None | False | 280181.0 | 0 |
| 2960779 | 97875 | None | CODE125 | Above 7.00m to 10.50m Level | Mtr | 514.47 | 514.47 | 1650.0 | False | None | None | False | None | False | 848875.5 | 0 |
| 2960780 | 97875 | None | CODE126 | Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of chemical, diluting in water to one percent concentration, labour, HOM of equipments, complete as per specifications. (Plinth area of the building at ground floor only shall be measured ) | Sqm | 144.81 | 144.81 | 13268.0 | False | None | None | False | None | False | 1921339.08 | 0 |
| 2960781 | 97875 | None | CODE127 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge. | Cum | 8180.52 | 8180.52 | 101.0 | False | None | None | False | None | False | 826232.52 | 0 |
| 2960782 | 97875 | None | CODE128 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA& for Residential Streets of approved shape and colour, laid inrequired pattern and including over 40mm thick compacted bedof coarse sand, filling the joints with fine sand etc. all complete asper the direction of Engineer-in-charge. (WMM/WBM Base to bepaid separately as per relevant technical specification) | Sqm | 1424.78 | 1424.78 | 200.0 | False | None | None | False | None | False | 284956.0 | 0 |
| 2960783 | 97875 | None | CODE129 | Providing and laying integral cement based waterproofing treatment iincluding preparation of surface as requried for treatment of roofs, balconies, terrace etc., consisting of following application. (a)Applying ang grouting a slurry coat of neat cement using 2.75kg/sqm of cement admixed with properly water proofing compound conforming to IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5 admixed with proprietary water proffing compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5 admixed with proprietary water proofing compound to required slope and treating similarly the adjoining walls upto 300mm height including rounding off junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of cement slurry admixed with proprietary water proofing compound. (D) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 admixed with proprietary water proofing compound and finally finishing the surface with trowel and neat cement slurry and making of 300x300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test including cost of materials, labour complete as per specifications.
Above 3.50m to 7.00m Level | Sqm | 1797.08 | 1797.08 | 613.0 | False | None | None | False | None | False | 1101610.04 | 0 |
| 2960784 | 97875 | None | CODE130 | Providing and fixing Steel work in built up tubular trusses (round, square or rectangular hollow tubes etc.) etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications andas per directions of the Engineer-in-Charge. For Truss / Gate & other structural steel works etc...
0.00m to 3.50m Level | Kgs | 180.4 | 180.4 | 1323.0 | False | None | None | False | None | False | 238669.2 | 0 |
| 2960785 | 97875 | None | CODE131 | Above 3.50m to 7.00m Level | Kgs | 182.2 | 182.2 | 705.0 | False | None | None | False | None | False | 128451.0 | 0 |
| 2960786 | 97875 | None | CODE132 | Pre-Engineering Structure
Providing & fixing All Primary steel including Rafters, Columns shall be Built up Sections made out of plates having a minimum yield strength of 345 Mpa. Grade 50 conforming to ASTM A 572 including providing & painting 2 coats of anticorrisive paint in apporved shade over a coat of primer & patti work. | MT | 166408.32 | 166408.32 | 641.0 | False | None | None | False | None | False | 106667733.12 | 0 |
| 2960787 | 97875 | None | CODE133 | Providing & fixing All M.S.Secondry structural Frame including Purlins, Girts shall be made out Cold Formed steel of min yield strength of 250 Mpa including providing & painting 2 coats of anticorrisive paint in apporved shade over a coat of primer & patti work. | MT | 166408.32 | 166408.32 | 199.0 | False | None | None | False | None | False | 33115255.68 | 0 |
| 2960788 | 97875 | None | CODE134 | Providing & fixing High tension foundation Bolts & nuts of various sizes having a minimum yield strength of 800 Mpa. at column bases, excluding cost of concrete including providing & painting 2 coats of anticorrisive paint in apporved shade over a coat of primer & patti work, fixing to be done by civil contractor under the supervision of PEB vNoor representative. | Kgs | 168.74 | 168.74 | 16995.0 | False | None | None | False | None | False | 2867736.3 | 0 |
| 2960789 | 97875 | None | CODE135 | Providing and Grouting the foundation bolts/pockets, base plates with ACC Shrink komp grade-2/ GP2 of FOSROC or FLOWGROUT 60 of FAIRMATE ready mixed non shrink, free flow, self leveling, cementitious grout making holes if necessary in concrete, curing etc. as per the recommNoations of the manufacturer, complete as directed. 50 to 60mm (Max) thick. | Sqm | 4460.4 | 4460.4 | 84.0 | False | None | None | False | None | False | 374673.6 | 0 |
| 2960790 | 97875 | None | CODE136 | Supplying insulated roof panels 30mm thick with rigid polyurethene foam (PUFF) insulation of 40 Kg/Cum density , panels to be laminated with colour coated (white, RAL 9002), corrugated, galvalume sheet of 0.40mm thick on top (outside), & lower skin of 0.40mm, galvanised steel (inside). The bottom layer shall be serated & top sheet is corrugated to match the roof profile including No caps as required. | Sqm | 2955.9 | 2955.9 | 12615.0 | False | None | None | False | None | False | 37288678.5 | 0 |
| 2960791 | 97875 | None | CODE137 | do-- 30mm thick with rigid polyurethene foam (PUFF) insulation of 40 Kg/Cum density, Sheet For Cladding. | Sqm | 2955.9 | 2955.9 | 7302.0 | False | None | None | False | None | False | 21583981.8 | 0 |
| 2960792 | 97875 | None | CODE138 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. For Roofing | Sqm | 697.05 | 697.05 | 304.0 | False | None | None | False | None | False | 211903.2 | 0 |
| 2960793 | 97875 | None | CODE139 | do-- For Cladding | Sqm | 697.05 | 697.05 | 3970.0 | False | None | None | False | None | False | 2767288.5 | 0 |
| 2960794 | 97875 | None | CODE140 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Gutter (600 mm over all girth) | Mtr | 1318.01 | 1318.01 | 483.0 | False | None | None | False | None | False | 636598.83 | 0 |
| 2960795 | 97875 | None | CODE141 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm) | Mtr | 553.47 | 553.47 | 319.0 | False | None | None | False | None | False | 176556.93 | 0 |
| 2960796 | 97875 | None | CODE142 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Flashings/ Aprons ( Upto 600 mm) | Mtr | 506.83 | 506.83 | 802.0 | False | None | None | False | None | False | 406477.66 | 0 |
| 2960797 | 97875 | None | CODE143 | Providing and fixing Aluminium Turbo ventilator complete as per technical specifications : Non Power Driven with 1.3mm thickness and 38 No.s of Vanes & turbine doom thickness 1mm and total weight not less than 6kg for Industrial use for area upto 100m2 for Industrial use | No | 6872.32 | 6872.32 | 20.0 | False | None | None | False | None | False | 137446.4 | 0 |
| 2960798 | 97875 | None | CODE144 | Providing and fixing 600 x600 size C.I. frames with cover of approved Ist quality and make conforming to I.S.I. Specification and fixing in C.C. (1:2:4) 7.5 cms thick including curing (Rate includes cost of all materials and conveyance to work spot). | No | 2950.0 | 2950.0 | 4.0 | False | None | None | False | None | False | 11800.0 | 0 |
| 2960799 | 97875 | None | CODE145 | Providing & fixing PVC Coated MS steps including embeding in concrete neat finishing etc complete. | No | 574.78 | 574.78 | 12.0 | False | None | None | False | None | False | 6897.36 | 0 |
| 2960800 | 97875 | None | CODE146 | P/f. 15 to 50 mm dia Puddle flanges in rcc using g.i.pipes with 6mm th. Plate as flage as per details. | No | 413.0 | 413.0 | 4.0 | False | None | None | False | None | False | 1652.0 | 0 |
| 2960801 | 97875 | None | CODE147 | do-- 65 to 100 mm dia Puddle flanges. | No | 708.0 | 708.0 | 4.0 | False | None | None | False | None | False | 2832.0 | 0 |
| 2960802 | 97875 | None | CODE148 | Constructing soak pit 2.5 m diameter 3.0 m deep with 45 x 45 cm dry brick honey comb shaft with bricks and PVC S.W.R drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay (non modular) bricks of class designation 3.5 including earthwork excavation, filling hard brick bats with charcoal etc. complete as per details | No | 33906.06 | 33906.06 | 2.0 | False | None | None | False | None | False | 67812.12 | 0 |
| 2960803 | 97875 | None | CODE149 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four No longitudinal & 9 No cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. | No | 1378.15 | 1378.15 | 50.0 | False | None | None | False | None | False | 68907.5 | 0 |
| 2960804 | 97875 | None | CODE150 | Supplying S&S RCC SPUN / VIBRATED CAST PIPES (REINFORCED) pipes NP-3 Class conforming to IS:458-1988 with latest amentments using ordinary portland cement, for sanitary works and conveying to work site, rolling and lowering into trenches, laying true to line and level including loading and unloading at both destinations and jointing of pipes and specials, perfect linking of joints with jack to correct position including cost of jointing materials, i.e, rubber rings conforming to IS: 5382 for S&S RCC pipes, with all leads and lifts as directed and giving necessary hydraulic test as per ISS to the required pressure and commissioning etc. complete. (Contractor will make his own arrangements for procuring water for testing). Before the execution of the work, the contractor shall carry out the survey.
300mm dia | Mtr | 1634.63 | 1634.63 | 25.0 | False | None | None | False | None | False | 40865.75 | 0 |
| 2960805 | 97875 | None | CODE151 | do-- 450mm dia | Mtr | 2887.6 | 2887.6 | 25.0 | False | None | None | False | None | False | 72190.0 | 0 |
| 2960806 | 97875 | None | CODE152 | do-- 600mm dia | Mtr | 3853.41 | 3853.41 | 10.0 | False | None | None | False | None | False | 38534.1 | 0 |
| 2960807 | 97875 | None | CODE153 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)
600 x 300 x 150 mm size | Mtr | 568.19 | 568.19 | 450.0 | False | None | None | False | None | False | 255685.5 | 0 |
| 2960808 | 97875 | None | CODE154 | Providing and fixing Pipe Cover on existing Storm Water Gutter 600 wide, with ISMC 75 @ 750 c/c, 65 dia GI - B class pipes @ 100 c/c & MS Flat Bracing @ 750c/c on top of pipes, welded to channel supports including channel support embedment in concrete M15, anticorrosive painting on shop primer etc complete. | Mtr | 7160.24 | 7160.24 | 20.0 | False | None | None | False | None | False | 143204.8 | 0 |
| 2960809 | 97875 | None | CODE155 | Demolishing existing building and disposal of debries fromwork site. | Job | 531000.0 | 531000.0 | 1.0 | False | None | None | False | None | False | 531000.0 | 0 |
| 2960810 | 97875 | None | CODE156 | SANITARY - PLUMBING WORKS
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 0.00m to 3.50m Level | No | 5993.64 | 5993.64 | 6.0 | False | None | None | False | None | False | 35961.84 | 0 |
| 2960811 | 97875 | None | CODE157 | Above 3.50m to 7.00m Level | No | 5993.64 | 5993.64 | 2.0 | False | None | None | False | None | False | 11987.28 | 0 |
| 2960812 | 97875 | None | CODE158 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bNo with fittings & C.I. brackets, 40 mm flush bNo, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
0.00m to 3.50m Level | No | 7334.97 | 7334.97 | 5.0 | False | None | None | False | None | False | 36674.85 | 0 |
| 2960813 | 97875 | None | CODE159 | Above 3.50m to 7.00m Level | No | 7334.97 | 7334.97 | 5.0 | False | None | None | False | None | False | 36674.85 | 0 |
| 2960814 | 97875 | None | CODE160 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge.
0.00m to 3.50m Level | No | 333.8 | 333.8 | 11.0 | False | None | None | False | None | False | 3671.8 | 0 |
| 2960815 | 97875 | None | CODE161 | Above 3.50m to 7.00m Level | No | 333.8 | 333.8 | 7.0 | False | None | None | False | None | False | 2336.6 | 0 |
| 2960816 | 97875 | None | CODE162 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
0.00m to 3.50m Level | No | 1416.19 | 1416.19 | 6.0 | False | None | None | False | None | False | 8497.14 | 0 |
| 2960817 | 97875 | None | CODE163 | Above 3.50m to 7.00m Level | No | 1416.19 | 1416.19 | 4.0 | False | None | None | False | None | False | 5664.76 | 0 |
| 2960818 | 97875 | None | CODE164 | Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm
with 1/2" BSP thread and shapes, weighing not less than 60 g.
0.00m to 3.50m Level | No | 112.9 | 112.9 | 6.0 | False | None | None | False | None | False | 677.4 | 0 |
| 2960819 | 97875 | None | CODE165 | Above 3.50m to 7.00m Level | No | 112.9 | 112.9 | 4.0 | False | None | None | False | None | False | 451.6 | 0 |
| 2960820 | 97875 | None | CODE166 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth.
0.00m to 3.50m Level | Sqm | 3422.66 | 3422.66 | 7.0 | False | None | None | False | None | False | 23958.62 | 0 |
| 2960821 | 97875 | None | CODE167 | Above 3.50m to 7.00m Level | Sqm | 3422.66 | 3422.66 | 3.0 | False | None | None | False | None | False | 10267.98 | 0 |
| 2960822 | 97875 | None | CODE168 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
0.00m to 3.50m Level | No | 3142.86 | 3142.86 | 11.0 | False | None | None | False | None | False | 34571.46 | 0 |
| 2960823 | 97875 | None | CODE169 | Above 3.50m to 7.00m Level | No | 3142.86 | 3142.86 | 7.0 | False | None | None | False | None | False | 22000.02 | 0 |
| 2960824 | 97875 | None | CODE170 | Providing and fixing CI / PVC Nahani trap of approved make conforming to ISI specifications and construction of Cistern in CC 1:2:4 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). 100x75mm including grating
0.00m to 3.50m Level | No | 269.98 | 269.98 | 36.0 | False | None | None | False | None | False | 9719.28 | 0 |
| 2960825 | 97875 | None | CODE171 | Above 3.50m to 7.00m Level | No | 269.98 | 269.98 | 16.0 | False | None | None | False | None | False | 4319.68 | 0 |
| 2960826 | 97875 | None | CODE172 | P/F 300 X 300 mm S.S. Industrial floor trap (Amul trap) including fixing in position as per details. | No | 9440.0 | 9440.0 | 2.0 | False | None | None | False | None | False | 18880.0 | 0 |
| 2960827 | 97875 | None | CODE173 | Providing and fixing C.P. brass bib cock of approved quality conforming
to IS:8931 - 0.00m to 3.50m Level | No | 779.27 | 779.27 | 29.0 | False | None | None | False | None | False | 22598.83 | 0 |
| 2960828 | 97875 | None | CODE174 | Above 3.50m to 7.00m Level | No | 779.27 | 779.27 | 7.0 | False | None | None | False | None | False | 5454.89 | 0 |
| 2960829 | 97875 | None | CODE175 | Providing and fixing C.P. brass stop cock (concealed) of standard design
and of approved make conforming to IS:8931.
0.00m to 3.50m Level | No | 889.72 | 889.72 | 36.0 | False | None | None | False | None | False | 32029.92 | 0 |
| 2960830 | 97875 | None | CODE176 | Above 3.50m to 7.00m Level | No | 889.72 | 889.72 | 16.0 | False | None | None | False | None | False | 14235.52 | 0 |
| 2960831 | 97875 | None | CODE177 | P/F Chorinated Poly chloride (CPVC) pipes conforming to IS 15778, having thermal stabilty for hot and clod water supply inclding all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one setp CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. - External Works a) 20mm dia.
0.00m to 3.50m Level | Mtr | 266.3 | 266.3 | 65.0 | False | None | None | False | None | False | 17309.5 | 0 |
| 2960832 | 97875 | None | CODE178 | Above 3.50m to 7.00m Level | Mtr | 266.3 | 266.3 | 25.0 | False | None | None | False | None | False | 6657.5 | 0 |
| 2960833 | 97875 | None | CODE179 | b) 25mm dia.
0.00m to 3.50m Level | Mtr | 363.25 | 363.25 | 85.0 | False | None | None | False | None | False | 30876.25 | 0 |
| 2960834 | 97875 | None | CODE180 | Above 3.50m to 7.00m Level | Mtr | 363.25 | 363.25 | 35.0 | False | None | None | False | None | False | 12713.75 | 0 |
| 2960835 | 97875 | None | CODE181 | c )32mm dia.
0.00m to 3.50m Level | Mtr | 456.52 | 456.52 | 200.0 | False | None | None | False | None | False | 91304.0 | 0 |
| 2960836 | 97875 | None | CODE182 | Above 3.50m to 7.00m Level | Mtr | 456.52 | 456.52 | 40.0 | False | None | None | False | None | False | 18260.8 | 0 |
| 2960837 | 97875 | None | CODE183 | P/F Chorinated Poly chloride (CPVC) pipes, having thermal stabilty for hot and clod water supply inclding all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00mtr spacing. This includes jointing of pipes and fittings with one setp CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Concealed work, including cutting chases and making good the walls etc. a) 20mm dia.
0.00m to 3.50m Level | Mtr | 465.11 | 465.11 | 120.0 | False | None | None | False | None | False | 55813.2 | 0 |
| 2960838 | 97875 | None | CODE184 | Above 3.50m to 7.00m Level | Mtr | 465.11 | 465.11 | 100.0 | False | None | None | False | None | False | 46511.0 | 0 |
| 2960839 | 97875 | None | CODE185 | b) 25mm dia.
0.00m to 3.50m Level | Mtr | 585.37 | 585.37 | 50.0 | False | None | None | False | None | False | 29268.5 | 0 |
| 2960840 | 97875 | None | CODE186 | Above 3.50m to 7.00m Level | Mtr | 585.37 | 585.37 | 40.0 | False | None | None | False | None | False | 23414.8 | 0 |
| 2960841 | 97875 | None | CODE187 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore
0.00m to 3.50m Level | No | 385.34 | 385.34 | 16.0 | False | None | None | False | None | False | 6165.44 | 0 |
| 2960842 | 97875 | None | CODE188 | Above 3.50m to 7.00m Level | No | 385.34 | 385.34 | 3.0 | False | None | None | False | None | False | 1156.02 | 0 |
| 2960843 | 97875 | None | CODE189 | 25 mm dia:
0.00m to 3.50m Level | No | 407.43 | 407.43 | 8.0 | False | None | None | False | None | False | 3259.44 | 0 |
| 2960844 | 97875 | None | CODE190 | Above 3.50m to 7.00m Level | No | 407.43 | 407.43 | 2.0 | False | None | None | False | None | False | 814.86 | 0 |
| 2960845 | 97875 | None | CODE191 | 32 mm dia:
0.00m to 3.50m Level | No | 448.17 | 448.17 | 3.0 | False | None | None | False | None | False | 1344.51 | 0 |
| 2960846 | 97875 | None | CODE192 | Above 3.50m to 7.00m Level | No | 448.17 | 448.17 | 1.0 | False | None | None | False | None | False | 448.17 | 0 |
| 2960847 | 97875 | None | CODE193 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 0.00m to 3.50m Level | No | 1497.18 | 1497.18 | 14.0 | False | None | None | False | None | False | 20960.52 | 0 |
| 2960848 | 97875 | None | CODE194 | Above 3.50m to 7.00m Level | No | 1497.18 | 1497.18 | 7.0 | False | None | None | False | None | False | 10480.26 | 0 |
| 2960849 | 97875 | None | CODE195 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. 0.00m to 3.50m Level | No | 608.69 | 608.69 | 14.0 | False | None | None | False | None | False | 8521.66 | 0 |
| 2960850 | 97875 | None | CODE196 | Above 3.50m to 7.00m Level | No | 608.69 | 608.69 | 7.0 | False | None | None | False | None | False | 4260.83 | 0 |
| 2960851 | 97875 | None | CODE197 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board - 610x510 mm bowl depth 200 mm 0.00m to 3.50m Level | No | 4448.6 | 4448.6 | 3.0 | False | None | None | False | None | False | 13345.8 | 0 |
| 2960852 | 97875 | None | CODE198 | Above 3.50m to 7.00m Level | No | 4448.6 | 4448.6 | 1.0 | False | None | None | False | None | False | 4448.6 | 0 |
| 2960853 | 97875 | None | CODE199 | Providing and fixing to wall, ceiling and floor, medium density polyethylene pipes 6.00kgf/sq.cm working pressure outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. a) 75mm dia pipe
0.00m to 3.50m Level | Mtr | 269.98 | 269.98 | 125.0 | False | None | None | False | None | False | 33747.5 | 0 |
| 2960854 | 97875 | None | CODE200 | Above 3.50m to 7.00m Level | Mtr | 269.98 | 269.98 | 70.0 | False | None | None | False | None | False | 18898.6 | 0 |
| 2960855 | 97875 | None | CODE201 | 110mm dia : 0.00m to 3.50m Level | Mtr | 504.38 | 504.38 | 75.0 | False | None | None | False | None | False | 37828.5 | 0 |
| 2960856 | 97875 | None | CODE202 | Above 3.50m to 7.00m Level | Mtr | 504.38 | 504.38 | 65.0 | False | None | None | False | None | False | 32784.7 | 0 |
| 2960857 | 97875 | None | CODE203 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | No | 424.61 | 424.61 | 13.0 | False | None | None | False | None | False | 5519.93 | 0 |
| 2960858 | 97875 | None | CODE204 | Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I. cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 Kg (Weight of cover 23Kg and weight of frame 15Kg) R.C.C. top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.
a) 455X610X450 | No | 6923.86 | 6923.86 | 12.0 | False | None | None | False | None | False | 83086.32 | 0 |
| 2960859 | 97875 | None | CODE205 | b) 455X610X450 - 750 | No | 9295.55 | 9295.55 | 18.0 | False | None | None | False | None | False | 167319.9 | 0 |
| 2960860 | 97875 | None | CODE206 | c) 500X700X600 -750 | No | 10289.58 | 10289.58 | 24.0 | False | None | None | False | None | False | 246949.92 | 0 |
| 2960861 | 97875 | None | CODE207 | Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amNoment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M depth & SFRC cover & frame | No | 38497.26 | 38497.26 | 4.0 | False | None | None | False | None | False | 153989.04 | 0 |
| 2960862 | 97875 | None | CODE208 | Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.5 M depth & SFRC cover & frame | No | 47101.16 | 47101.16 | 2.0 | False | None | None | False | None | False | 94202.32 | 0 |
| 2960863 | 97875 | None | CODE209 | Providing and fixing to wall, ceiling and floor, high density polyethylene pipes 6.00kgf/sq.cm working pressure 110mm outside diameter with special flange, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing complete as per specifications. | Mtr | 357.12 | 357.12 | 125.0 | False | None | None | False | None | False | 44640.0 | 0 |
| 2960864 | 97875 | None | CODE210 | 160 mm dia | Mtr | 697.05 | 697.05 | 230.0 | False | None | None | False | None | False | 160321.5 | 0 |
| 2960865 | 97875 | None | CODE211 | Providing and fixing rectangular high density polythylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making ncessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixures for tank shall be paid seperately. READ THE UNIT OF MEASUREMENT AS LITRES | No | 11.04 | 11.04 | 9000.0 | False | None | None | False | None | False | 99360.0 | 0 |
| 2960866 | 97875 | None | CODE212 | Providing & fixing S.S. Handwash trough 450mm wide made out of 304 grade, 1.00mm thick s.s. sheets with waste connections etc complete as per details. | Mtr | 8850.0 | 8850.0 | 2.5 | False | None | None | False | None | False | 22125.0 | 0 |
| 2960867 | 97875 | None | CODE213 | ELECTRICAL WORKS
(A) LT PANEL AND MCB DISTRIBUTION BOARDS : LT PANEL : Supply, installation, testing and commissioning of M.V. panels and switch gears suitable for 415V, 3 phase, 4 wire, 50Hz power distribution system. The panel shall be free standing floor mounting type 14G/16G sheet steel enclosed, flush front with aluminium bus bars and separate earth bus to be provided through out the length of the panel. The incoming and out going feeders breakers, changer over switches, fuses indicating lamps shall be accomadated in a modular multitier arangement. Minimum clearance of 400mm shall be provided from the floor level to the bottom most termination point adequate size cable alley and bus bar chamber shall be provided, all round the panel and it shall be connected through solid bus bars. Flexible cable links are not acceptable .
Bus bars shall be provided with sleeves or heat resistant insulated paint. The paint shall be suitable for both top/bottom cable entry. The minimum fault rupturing capacity of all incoming and out going breakers/ switches shall be as per SLD only. The panel shall be painted in conformity with the relevant IS code. The panel shall be fabricated only after obtaining approval of the GA drawings. The rate shall also include cost of civil works including fixing accessories, all complete as required
SMP- L & P
Incomer :
1no. 125A, TPN MCCB
1set of RYB indicating lamps
1no. VAF meter with suitable CT
1no. ELR with CBCT
1 set of 125A, TPN+E, Al. Busbar
Outgoings :
2No. 63A, TPN MCCB
5No. 25A, TPN MCB
1no. 20A, TPN MCB
3No. 40A, TPN MCB
3No. 63A, TPN MCB | Set | 128930.34 | 128930.34 | 1.0 | False | None | None | False | None | False | 128930.34 | 0 |
| 2960868 | 97875 | None | CODE214 | SDB-ADMIN
Incomer :
1no. 63A, TPN MCCB
1set of RYB indicating lamps
1no. VAF meter with suitable CT
1no. ELR with CBCT
1 set of 250A, TPN+E, Al. Busbar
Outgoings :
4No. 32A, TPN MCB
4No. 25A, TPN MCB | Set | 81670.16 | 81670.16 | 1.0 | False | None | None | False | None | False | 81670.16 | 0 |
| 2960869 | 97875 | None | CODE215 | UPS OUTPUT PANEL
Incomer :
1no. 40A, TPN MCB
1set of RYB indicating lamps
1no. VAF meter with suitable CT
1 set of 250A, TPN+E, Al. Busbar
Outgoings :
2No. 32A, TPN MCB
1no. 20A, TPN MCB
2No. 25A, SP MCB
4No. 6A, SP MCB | Set | 34838.32 | 34838.32 | 1.0 | False | None | None | False | None | False | 34838.32 | 0 |
| 2960870 | 97875 | None | CODE216 | DISTRIBUTION BOARDS: Supplying and fixing regular MCB distribution boards on wall/wood board/ flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase/ double door with powder coated painting made out of 14 SWG MS enclosure etc, complete as required.
SDB-CANTEEN
4 Way TPN MCB DB
Incomer :
1 No. 40A TPN MCB
Outgoings :
2No. of 20A SP MCBs
2No. of 25/32A TP MCBs | Set | 13923.81 | 13923.81 | 1.0 | False | None | None | False | None | False | 13923.81 | 0 |
| 2960871 | 97875 | None | CODE217 | SDB-1
8 Way TPN MCB DB
Incomer :
1 No. 63A TPN MCB
Outgoings :
8No. of 25/32A TP MCBs | Set | 28121.29 | 28121.29 | 1.0 | False | None | None | False | None | False | 28121.29 | 0 |
| 2960872 | 97875 | None | CODE218 | SDB-2
4 Way TPN MCB DB
Incomer :
1 No. 63A TPN MCB
Outgoings :
4No. of 25/32A TP MCBs | Set | 17173.44 | 17173.44 | 1.0 | False | None | None | False | None | False | 17173.44 | 0 |
| 2960873 | 97875 | None | CODE219 | SDB-3
6 Way TPN MCB DB
Incomer :
1 No. 63A TPN MCB
Outgoings :
6No. of 25/32A TP MCBs | Set | 22494.58 | 22494.58 | 1.0 | False | None | None | False | None | False | 22494.58 | 0 |
| 2960874 | 97875 | None | CODE220 | SDB-UPS / OFF
4 Way TPN MCB DB
Incomer :
1 No. 32A TPN MCB
Outgoings :
4No. of 25A TP MCBs | Set | 15490.95 | 15490.95 | 1.0 | False | None | None | False | None | False | 15490.95 | 0 |
| 2960875 | 97875 | None | CODE221 | LDB -TYPE-1
4 Way TPN MCB DB
Incomer :
1 No. 25A 4P RCCB 100mA + 25A TPN MCB
Outgoings :
12 No. of 6/10A SP MCBs | Set | 19390.99 | 19390.99 | 7.0 | False | None | None | False | None | False | 135736.93 | 0 |
| 2960876 | 97875 | None | CODE222 | LDB -TYPE-2
6 Way TPN MCB DB
Incomer :
1 No. 25A 4P RCCB 100mA + 25A TPN MCB
Outgoings :
18 No. of 6/10A SP MCBs | Set | 23553.65 | 23553.65 | 4.0 | False | None | None | False | None | False | 94214.6 | 0 |
| 2960877 | 97875 | None | CODE223 | LDB -TYPE-3
8 Way SPN MCB DB
Incomer :
1 No. 25A DP RCCB 100mA + 25A DP MCB
Outgoings :
6 No. of 6/10A SP MCBs | Set | 11486.59 | 11486.59 | 1.0 | False | None | None | False | None | False | 11486.59 | 0 |
| 2960878 | 97875 | None | CODE224 | RPDB -TYPE-1
4 Way TPN MCB DB
Incomer :
1 No. 32A 4P RCCB 300mA + 32A TPN MCB
Outgoings :
12 No. of 6/10A SP MCBs | Set | 19490.39 | 19490.39 | 3.0 | False | None | None | False | None | False | 58471.17 | 0 |
| 2960879 | 97875 | None | CODE225 | RPDB -TYPE-2
8 Way TPN MCB DB
Incomer :
1 No. 32A 4PRCCB 300mA + 32A TPN MCB
Outgoings :
9 No. of 6/10A SP MCBs
4 No. of 16A TP MCBs | Set | 28910.38 | 28910.38 | 1.0 | False | None | None | False | None | False | 28910.38 | 0 |
| 2960880 | 97875 | None | CODE226 | RPDB -TYPE-3
6 Way TPN MCB DB
Incomer :
1 No. 32A 4P RCCB 300mA + 32A TPN MCB
Outgoings :
5 No. of 6/10A SP MCBs
4 No. of 16A TP MCBs | Set | 25460.72 | 25460.72 | 2.0 | False | None | None | False | None | False | 50921.44 | 0 |
| 2960881 | 97875 | None | CODE227 | RPDB -TYPE-4
8 Way TPN MCB DB
Incomer :
1 No. 32A 4P RCCB 300mA + 32A TPN MCB
Outgoings :
3 No. of 6/10A SP MCBs
7 No. of 16A TP MCBs | Set | 32175.96 | 32175.96 | 1.0 | False | None | None | False | None | False | 32175.96 | 0 |
| 2960882 | 97875 | None | CODE228 | RPDB -TYPE-5
4 Way TPN MCB DB
Incomer :
1 No. 32A 4P RCCB 300mA + 32A TPN MCB
Outgoings :
3 No. of 6/10A SP MCBs
3 No. of 16A TP MCBs | Set | 21228.11 | 21228.11 | 2.0 | False | None | None | False | None | False | 42456.22 | 0 |
| 2960883 | 97875 | None | CODE229 | EL & UPSDB -TYPE-1
4 Way TPN MCB DB
Incomer :
1 No. 25A TPN MCB
Outgoings :
12 No. of 6/10A SP MCBs | Set | 13173.99 | 13173.99 | 3.0 | False | None | None | False | None | False | 39521.97 | 0 |
| 2960884 | 97875 | None | CODE230 | EL & UPSDB -TYPE-2
8 Way SPN MCB DB
Incomer :
1 No. 25A DP MCB
Outgoings :
6 No. of 6/10A SP MCBs | Set | 6237.86 | 6237.86 | 2.0 | False | None | None | False | None | False | 12475.72 | 0 |
| 2960885 | 97875 | None | CODE231 | EL & UPSDB -TYPE-3
6 Way SPN MCB DB
Incomer :
1 No. 25A DP MCB
Outgoings :
4 No. of 6/10A SP MCBs | Set | 5141.97 | 5141.97 | 3.0 | False | None | None | False | None | False | 15425.91 | 0 |
| 2960886 | 97875 | None | CODE232 | LPDB -TYPE-1
4 Way TPN MCB DB
Incomer :
1 No. 25A 4P RCCB 100mA + 25A TPN MCB
Outgoings :
12 No. of 6/10/16A SP MCBs | Set | 19390.99 | 19390.99 | 1.0 | False | None | None | False | None | False | 19390.99 | 0 |
| 2960887 | 97875 | None | CODE233 | LPDB -TYPE-2
6 Way TPN MCB DB
Incomer :
1 No. 25A 4P RCCB 100mA + 25A TPN MCB
Outgoings :
6 No. of 6/10A SP MCBs
3 No. of 16A TP MCBs | Set | 23763.5 | 23763.5 | 1.0 | False | None | None | False | None | False | 23763.5 | 0 |
| 2960888 | 97875 | None | CODE234 | LPDB -TYPE-3
4 Way TPN MCB DB
Incomer :
1 No. 25A 4P RCCB 100mA + 25A TPN MCB
Outgoings :
3 No. of 6/10A SP MCBs
2 No. of 16A TP MCBs | Set | 19021.6 | 19021.6 | 2.0 | False | None | None | False | None | False | 38043.2 | 0 |
| 2960889 | 97875 | None | CODE235 | LDB-EXT
6 Way TPN MCB DB
Incomer :
1 No. 20A TPN MCB
Outgoings :
8 No. of 6/10A SP MCBs
3No. 16A Astronomical timer Switch | Set | 30073.76 | 30073.76 | 1.0 | False | None | None | False | None | False | 30073.76 | 0 |
| 2960890 | 97875 | None | CODE236 | Supplying and fixing of following rating, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.16A, DP MCB | Each | 509.29 | 509.29 | 12.0 | False | None | None | False | None | False | 6111.48 | 0 |
| 2960891 | 97875 | None | CODE237 | 16A TPN MCB | Each | 2107.1 | 2107.1 | 45.0 | False | None | None | False | None | False | 94819.5 | 0 |
| 2960892 | 97875 | None | CODE238 | Supply, installation, testing and commissioning of metal enclosure. The enclosure. shall be wall mounted using necessary brackets and fixing accessories. SP enclosure | Each | 571.12 | 571.12 | 12.0 | False | None | None | False | None | False | 6853.44 | 0 |
| 2960893 | 97875 | None | CODE239 | TPN enclosure | Each | 785.29 | 785.29 | 45.0 | False | None | None | False | None | False | 35338.05 | 0 |
| 2960894 | 97875 | None | CODE240 | B. LT cable and terminations : Supply & Laying of 1100V grade, XLPE/ PVC insulated, PVC sheathed, Aluminium / copper conductor, steel armoured cables. The cable shall be laid in exsiting trench, cable tray / clamped on to the walls using necessary fixing accessories, The cable shall be provided with cable identification tags made out of Aluminium strip, engraved with cable size and the routing. (Note : cost of cable tray, supports, excavation, sand cushioning, brick protection and back filling measured separately).
3.5C 95 sqmm Al. XLPE Cable | Mtr | 702.68 | 702.68 | 30.0 | False | None | None | False | None | False | 21080.4 | 0 |
| 2960895 | 97875 | None | CODE241 | 3.5C 25 sqmm Al. XLPE Cable | Mtr | 296.31 | 296.31 | 241.0 | False | None | None | False | None | False | 71410.71 | 0 |
| 2960896 | 97875 | None | CODE242 | 4C 16 sqmm Al. XLPE Cable | Mtr | 299.72 | 299.72 | 560.0 | False | None | None | False | None | False | 167843.2 | 0 |
| 2960897 | 97875 | None | CODE243 | 4C 10 sqmm Al. XLPE Cable | Mtr | 249.47 | 249.47 | 420.0 | False | None | None | False | None | False | 104777.4 | 0 |
| 2960898 | 97875 | None | CODE244 | 4C 6 sqmm Al. XLPE Cable | Mtr | 402.52 | 402.52 | 2434.0 | False | None | None | False | None | False | 979733.68 | 0 |
| 2960899 | 97875 | None | CODE245 | 3C 6 sqmm Al. XLPE Cable | Mtr | 310.48 | 310.48 | 475.0 | False | None | None | False | None | False | 147478.0 | 0 |
| 2960900 | 97875 | None | CODE246 | 4C X 10 Sq.mm unarm. Cu .Arm Cable | Mtr | 234.62 | 234.62 | 30.0 | False | None | None | False | None | False | 7038.6 | 0 |
| 2960901 | 97875 | None | CODE247 | 3C X 2.5 Sq.mm arm. Cu .Arm Cable | Mtr | 138.67 | 138.67 | 70.0 | False | None | None | False | None | False | 9706.9 | 0 |
| 2960902 | 97875 | None | CODE248 | Supply and providing No termination for below listed PVC insulated, PVC sheathed, aluminium conductor,steel armoured, 1100V grade , cable using brass cable glands and copper lugs etc, all complete as required.
3.5C 95 sqmm Al. XLPE Cable | No | 1634.63 | 1634.63 | 2.0 | False | None | None | False | None | False | 3269.26 | 0 |
| 2960903 | 97875 | None | CODE249 | 3.5C 25 sqmm Al. XLPE Cable | No | 153.15 | 153.15 | 2.0 | False | None | None | False | None | False | 306.3 | 0 |
| 2960904 | 97875 | None | CODE250 | 4C 16 sqmm Al. XLPE Cable | No | 118.46 | 118.46 | 6.0 | False | None | None | False | None | False | 710.76 | 0 |
| 2960905 | 97875 | None | CODE251 | 4C 10 sqmm Al. XLPE Cable | No | 118.46 | 118.46 | 4.0 | False | None | None | False | None | False | 473.84 | 0 |
| 2960906 | 97875 | None | CODE252 | 4C 6 sqmm Al. XLPE Cable | No | 118.46 | 118.46 | 70.0 | False | None | None | False | None | False | 8292.2 | 0 |
| 2960907 | 97875 | None | CODE253 | 3C 6 sqmm Al. XLPE Cable | No | 118.46 | 118.46 | 8.0 | False | None | None | False | None | False | 947.68 | 0 |
| 2960908 | 97875 | None | CODE254 | 4C X 10 Sq.mm unarm. Cu .Arm Cable | No | 118.46 | 118.46 | 4.0 | False | None | None | False | None | False | 473.84 | 0 |
| 2960909 | 97875 | None | CODE255 | 3C X 2.5 Sq.mm arm. Cu .Arm Cable | No | 118.46 | 118.46 | 8.0 | False | None | None | False | None | False | 947.68 | 0 |
| 2960910 | 97875 | None | CODE256 | Supply and fixing of conduit / structural steel support ceiling suspNoed type / wall bracket type clamps with necessary saddles for fixing of conduits / cables, cable trays and where ever necessary. The detail of supports shall be made as per the site condition and duly approved by architect/ consultant before erection. (The contractor shall submit the GA drawing for the supports and shall be executed after getting approval from consultant) | Kgs | 138.67 | 138.67 | 6750.0 | False | None | None | False | None | False | 936022.5 | 0 |
| 2960911 | 97875 | None | CODE257 | Providing and laying Double wall Corrugated HDPE pipes for Electrical. Telecommunication & Signalling lines having flexibility & anti termite, anti corrosive, good abrasion, fatigue strength & UV resistant and capable of withstanding vehicular traffic and earth loads conforming to IS 16205:2017 as per technical specifications.
63mm Outer dia | Mtr | 116.58 | 116.58 | 250.0 | False | None | None | False | None | False | 29145.0 | 0 |
| 2960912 | 97875 | None | CODE258 | 110 mm Outer dia | Mtr | 245.44 | 245.44 | 100.0 | False | None | None | False | None | False | 24544.0 | 0 |
| 2960913 | 97875 | None | CODE259 | 160 mm Outer dia | Mtr | 413.0 | 413.0 | 50.0 | False | None | None | False | None | False | 20650.0 | 0 |
| 2960914 | 97875 | None | CODE260 | 200 mm Outer dia | Mtr | 632.01 | 632.01 | 50.0 | False | None | None | False | None | False | 31600.5 | 0 |
| 2960915 | 97875 | None | CODE261 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 593.96 | 593.96 | 565.0 | False | None | None | False | None | False | 335587.4 | 0 |
| 2960916 | 97875 | None | CODE262 | Sand Filling in Wells / Cable Trenches complete as per Drawing and Technical Specifications. | Cum | 3167.4 | 3167.4 | 75.0 | False | None | None | False | None | False | 237555.0 | 0 |
| 2960917 | 97875 | None | CODE263 | Supply and laying of brick protection for under ground cables laid in existing trench. | Mtr | 136.61 | 136.61 | 800.0 | False | None | None | False | None | False | 109288.0 | 0 |
| 2960918 | 97875 | None | CODE264 | Supply & installation of hot dip galvanized sheet steel bolted rung type ladder cable trays with suitable bNos, off sets wherever required. The supporting brackets shall be of U type with suitable size angle iron frame fixed with anchor fasteners, screw, bolts & nuts etc., (Note : The bNos, off sets shall be fabricated at site as per site requirement). The rate shall include the cost of bolt, nuts, fasteners etc.. The contractor has to submit the GA drawing for the cable tray and support to consultant / Architect. Note : The cost of supports shall be measured separately
750 mm x 50 mm x 2.00 mm | Mtr | 1619.9 | 1619.9 | 50.0 | False | None | None | False | None | False | 80995.0 | 0 |
| 2960919 | 97875 | None | CODE265 | 600 mm x 50 mm x 2.00 mm | Mtr | 1273.83 | 1273.83 | 90.0 | False | None | None | False | None | False | 114644.7 | 0 |
| 2960920 | 97875 | None | CODE266 | 450 mm x 50 mm x 2.00 mm | Mtr | 1204.62 | 1204.62 | 270.0 | False | None | None | False | None | False | 325247.4 | 0 |
| 2960921 | 97875 | None | CODE267 | 300 mm x 50 mm x 2.00 mm | Mtr | 780.5 | 780.5 | 270.0 | False | None | None | False | None | False | 210735.0 | 0 |
| 2960922 | 97875 | None | CODE268 | 200 mm x 50 mm x 2.00 mm | Mtr | 625.87 | 625.87 | 250.0 | False | None | None | False | None | False | 156467.5 | 0 |
| 2960923 | 97875 | None | CODE269 | 150 mm x 50 mm x 2.00 mm | Mtr | 625.87 | 625.87 | 250.0 | False | None | None | False | None | False | 156467.5 | 0 |
| 2960924 | 97875 | None | CODE270 | C. WIRING SYSTEM : Supplying and wiring adopting loop system in suitable size PVC Conduit/casing capping casing capping using2x1.5Sqmm (Phase & Neutral) &1x1.0sqmm (Earthwire)FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amNoments) without control switch shall be fixed on the existing plastic sheet/gang box ,the other No of the wires shall be terminated with sufficient loose length in a wood/ PVC round block. complete for each outlet. -Short point upto 3m | No | 576.78 | 576.78 | 14.0 | False | None | None | False | None | False | 8074.92 | 0 |
| 2960925 | 97875 | None | CODE271 | Medium point above 3 mtrs upto 6 mtrs. | No | 958.44 | 958.44 | 40.0 | False | None | None | False | None | False | 38337.6 | 0 |
| 2960926 | 97875 | None | CODE272 | Long point above 6 mtrs upto 10 mtrs. | No | 1503.32 | 1503.32 | 90.0 | False | None | None | False | None | False | 135298.8 | 0 |
| 2960927 | 97875 | None | CODE273 | Two in a row above 3 mts upto 6 mtrs from tapping point to outlet via switch box | No | 1324.15 | 1324.15 | 49.0 | False | None | None | False | None | False | 64883.35 | 0 |
| 2960928 | 97875 | None | CODE274 | Three in a row above 6 mts upto10 mtrs from tapping point to outlet via switch box | No | 2035.92 | 2035.92 | 33.0 | False | None | None | False | None | False | 67185.36 | 0 |
| 2960929 | 97875 | None | CODE275 | Ceiling fan point controlled by 6A modular type switch and fan regulator. Medium point above 3 mtrs upto 6 mtrs. | No | 958.44 | 958.44 | 19.0 | False | None | None | False | None | False | 18210.36 | 0 |
| 2960930 | 97875 | None | CODE276 | Long point above 6 mtrs upto 10 mtrs. | No | 1503.32 | 1503.32 | 40.0 | False | None | None | False | None | False | 60132.8 | 0 |
| 2960931 | 97875 | None | CODE277 | Exhaust fan point (Single phase) controlled by 6A modular type switch and 6A socket outlet near the exhaust fan - Medium point above 3 mtrs upto 6 mtrs. | No | 958.44 | 958.44 | 7.0 | False | None | None | False | None | False | 6709.08 | 0 |
| 2960932 | 97875 | None | CODE278 | Supply & Wiring for Lights using 2.5 sqmm flexible copper, 1100 volts grade PVC insulated wires drawn through 2mm thick, suitable size PVC conduit in concealed manner using necessary conduit accessories like junction boxes, bNos, collars, clamps, ceiling roses, etc., and shall be flush mounted in brick wall or on the surface of wall for surface installation as required. Also the rate shall include earthing of each light point using 1.5sqmm, flexible, copper conductor, PVC insulated wires. Note : 1) MCB's shall be measured separately. 2) The additional length of point wiring shall be measured separately as lighting circuit.
2L/1 MCB (20 mts) | No | 4332.02 | 4332.02 | 152.0 | False | None | None | False | None | False | 658467.04 | 0 |
| 2960933 | 97875 | None | CODE279 | 3L/1 MCB (25 mts) | No | 5411.95 | 5411.95 | 28.0 | False | None | None | False | None | False | 151534.6 | 0 |
| 2960934 | 97875 | None | CODE280 | CIRCUIT MAIN / POWER MAIN / SUBMAINS : Supplying and wiring for lighting circuit mains/ power mains/submains, using one of FRLS PVC insulated 1100V grade, multistrand Copper conductor single core cable in open or concealed slab / groove cutting system of wiring including required bNos and accessories. 2x1.5 Sqmm +1x1.0 Sqmm PVC Insulated wires drawn in 20mm dia PVC conduit for additional length of point wiring. | Mtr | 169.35 | 169.35 | 200.0 | False | None | None | False | None | False | 33870.0 | 0 |
| 2960935 | 97875 | None | CODE281 | 2 x 2.5 Sqmm + 1 x 1.5 Sq mm PVC Insulated wires drawn in 20 mm dia PVC conduit | Mtr | 217.21 | 217.21 | 5000.0 | False | None | None | False | None | False | 1086050.0 | 0 |
| 2960936 | 97875 | None | CODE282 | 2 x 4 Sqmm + 1 x 2.5 Sq mm PVC Insulated wires drawn in 20 mm dia PVC conduit | Mtr | 288.39 | 288.39 | 1400.0 | False | None | None | False | None | False | 403746.0 | 0 |
| 2960937 | 97875 | None | CODE283 | 2 x 6 Sqmm + 1 x 4 Sq mm PVC Insulated wires drawn in 32 mm dia PVC conduit. | Mtr | 427.07 | 427.07 | 30.0 | False | None | None | False | None | False | 12812.1 | 0 |
| 2960938 | 97875 | None | CODE284 | 4 x 2.5 Sqmm + 2 x 1.5 Sq mm PVC Insulated wires drawn in 25 mm dia PVC conduit | Mtr | 366.32 | 366.32 | 1800.0 | False | None | None | False | None | False | 659376.0 | 0 |
| 2960939 | 97875 | None | CODE285 | 4 x 4 Sqmm + 2 x 2.5 Sq mm PVC Insulated wires drawn in 25 mm dia PVC conduit | Mtr | 508.67 | 508.67 | 50.0 | False | None | None | False | None | False | 25433.5 | 0 |
| 2960940 | 97875 | None | CODE286 | 4 x 6 Sqmm + 2 x 4 Sq mm PVC Insulated wires drawn in 32 mm dia PVC conduit. | Mtr | 730.18 | 730.18 | 1100.0 | False | None | None | False | None | False | 803198.0 | 0 |
| 2960941 | 97875 | None | CODE287 | 4 x 10Sqmm + 2 x 6 Sq mm PVC Insulated wires drawn in 40 mm dia PVC conduit. | Mtr | 1221.06 | 1221.06 | 900.0 | False | None | None | False | None | False | 1098954.0 | 0 |
| 2960942 | 97875 | None | CODE288 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. (Group-A) 1 to 2Way | No | 169.35 | 169.35 | 160.0 | False | None | None | False | None | False | 27096.0 | 0 |
| 2960943 | 97875 | None | CODE289 | 3 Way | No | 195.12 | 195.12 | 100.0 | False | None | None | False | None | False | 19512.0 | 0 |
| 2960944 | 97875 | None | CODE290 | 4-5 Way | No | 217.21 | 217.21 | 20.0 | False | None | None | False | None | False | 4344.2 | 0 |
| 2960945 | 97875 | None | CODE291 | 6 Way | No | 269.98 | 269.98 | 17.0 | False | None | None | False | None | False | 4589.66 | 0 |
| 2960946 | 97875 | None | CODE292 | 8 Way | No | 320.3 | 320.3 | 10.0 | False | None | None | False | None | False | 3203.0 | 0 |
| 2960947 | 97875 | None | CODE293 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required No. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. Group A materials 1 to 2 module | No | 168.13 | 168.13 | 160.0 | False | None | None | False | None | False | 26900.8 | 0 |
| 2960948 | 97875 | None | CODE294 | 3 Module | No | 197.58 | 197.58 | 100.0 | False | None | None | False | None | False | 19758.0 | 0 |
| 2960949 | 97875 | None | CODE295 | 4 module | No | 214.76 | 214.76 | 20.0 | False | None | None | False | None | False | 4295.2 | 0 |
| 2960950 | 97875 | None | CODE296 | 6 module | No | 287.16 | 287.16 | 17.0 | False | None | None | False | None | False | 4881.72 | 0 |
| 2960951 | 97875 | None | CODE297 | 8 module | No | 348.52 | 348.52 | 10.0 | False | None | None | False | None | False | 3485.2 | 0 |
| 2960952 | 97875 | None | CODE298 | Supplying and fixing of modular switch/ Socket / stepped electronic fan regulator / dimmer / telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. Group B | No | 125.17 | 125.17 | 375.0 | False | None | None | False | None | False | 46938.75 | 0 |
| 2960953 | 97875 | None | CODE299 | 6Amps 3way socket. | No | 209.85 | 209.85 | 83.0 | False | None | None | False | None | False | 17417.55 | 0 |
| 2960954 | 97875 | None | CODE300 | 16Amps one way switch | No | 220.9 | 220.9 | 25.0 | False | None | None | False | None | False | 5522.5 | 0 |
| 2960955 | 97875 | None | CODE301 | 6/16Amps universal socket | No | 289.62 | 289.62 | 25.0 | False | None | None | False | None | False | 7240.5 | 0 |
| 2960956 | 97875 | None | CODE302 | Stepped Fan Regulator. | No | 438.11 | 438.11 | 59.0 | False | None | None | False | None | False | 25848.49 | 0 |
| 2960957 | 97875 | None | CODE303 | Supplying and fixing of metal clad industrial plugs and sockets
2pole + earth 250V PLUG - 16A | Each | 475.86 | 475.86 | 12.0 | False | None | None | False | None | False | 5710.32 | 0 |
| 2960958 | 97875 | None | CODE304 | 3pole + earth 440V PLUG - 16A | Each | 554.85 | 554.85 | 45.0 | False | None | None | False | None | False | 24968.25 | 0 |
| 2960959 | 97875 | None | CODE305 | 2pole+earth 250V SOCKET - 16A | Each | 651.61 | 651.61 | 12.0 | False | None | None | False | None | False | 7819.32 | 0 |
| 2960960 | 97875 | None | CODE306 | 3pole+earth 440V SOCKET - 16A | Each | 777.77 | 777.77 | 45.0 | False | None | None | False | None | False | 34999.65 | 0 |
| 2960961 | 97875 | None | CODE307 | D. SUPPLY & INSTALLATION OF LIGHT & FAN FIXTURES: Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V AT 50/60Hz AND Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition
LED square or round down light 5-6W | No | 700.73 | 700.73 | 25.0 | False | None | None | False | None | False | 17518.25 | 0 |
| 2960962 | 97875 | None | CODE308 | LED square or round down light 10-12W | No | 1086.07 | 1086.07 | 55.0 | False | None | None | False | None | False | 59733.85 | 0 |
| 2960963 | 97875 | None | CODE309 | LED square or round down light 15-18W | No | 1624.81 | 1624.81 | 58.0 | False | None | None | False | None | False | 94238.98 | 0 |
| 2960964 | 97875 | None | CODE310 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED light fitting 1 x 4' - 20/22 W | No | 846.77 | 846.77 | 41.0 | False | None | None | False | None | False | 34717.57 | 0 |
| 2960965 | 97875 | None | CODE311 | LED light fitting 1 x 4' - 36/40 W | No | 1557.32 | 1557.32 | 48.0 | False | None | None | False | None | False | 74751.36 | 0 |
| 2960966 | 97875 | None | CODE312 | Supplying of 40 W LED IP-65 Tube Light fixture of type CIS-300-40-57-SL-DP-NGR of CG make/equivalent. | No | 2738.78 | 2738.78 | 15.0 | False | None | None | False | None | False | 41081.7 | 0 |
| 2960967 | 97875 | None | CODE313 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.
LED modular down light 2'x2' 36 W | No | 5587.44 | 5587.44 | 96.0 | False | None | None | False | None | False | 536394.24 | 0 |
| 2960968 | 97875 | None | CODE314 | Supplying of 2 x22 W battery operated wall mounted light fixture of type HV203 of ABB make / equivalent. The light fixture shall comprise of lamp, battery with back up 3hrs. rating , battery charging unit and other necessary accessories | No | 31625.77 | 31625.77 | 26.0 | False | None | None | False | None | False | 822270.02 | 0 |
| 2960969 | 97875 | None | CODE315 | Fixing all types and all capacities fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling/ rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required No of round blocks and clamps. On wall / ceiling / Rafter / girders | No | 149.72 | 149.72 | 363.0 | False | None | None | False | None | False | 54348.36 | 0 |
| 2960970 | 97875 | None | CODE316 | Supplying of 350W LED, flood Light Fixture of type CFS-501-350-57-60D-SL-GL-NGG of CG make/equivalent. | No | 32982.18 | 32982.18 | 180.0 | False | None | None | False | None | False | 5936792.4 | 0 |
| 2960971 | 97875 | None | CODE317 | Fixing halogen/metal/LED flood light fitting on wall including clamps, bolts, nuts, and wiring using suitable capacity wires | No | 198.81 | 198.81 | 180.0 | False | None | None | False | None | False | 35785.8 | 0 |
| 2960972 | 97875 | None | CODE318 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, and 50 cycles. Single phase AC supply conforming to IS-374-1979 and with double ball bearing system and as per technical data approved. 48" sweep (1200mm) economy model | Each | 3285.21 | 3285.21 | 59.0 | False | None | None | False | None | False | 193827.39 | 0 |
| 2960973 | 97875 | None | CODE319 | Fixing a ceiling fan of all capacities and all types with necessary clamps & S hook made out of 15mm dia MS rod, with 5 amps ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality mounted on a suitable size wodden board and wired complete. | No | 386.57 | 386.57 | 59.0 | False | None | None | False | None | False | 22807.63 | 0 |
| 2960974 | 97875 | None | CODE320 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable for operate on 230V 50Hz, AC Supply. | No | 1830.98 | 1830.98 | 8.0 | False | None | None | False | None | False | 14647.84 | 0 |
| 2960975 | 97875 | None | CODE321 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make. | No | 603.78 | 603.78 | 8.0 | False | None | None | False | None | False | 4830.24 | 0 |
| 2960976 | 97875 | None | CODE322 | E) External lighting : Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4No of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appNoed.
7 meters - Top 70mm and bottom 130mm dia | No | 16567.2 | 16567.2 | 17.0 | False | None | None | False | None | False | 281642.4 | 0 |
| 2960977 | 97875 | None | CODE323 | 9 meters - Top 70mm and bottom 155mm dia | No | 23930.4 | 23930.4 | 13.0 | False | None | None | False | None | False | 311095.2 | 0 |
| 2960978 | 97875 | None | CODE324 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.
Single Arm Bracket with 1000mm Standard 40/50MM dia | Each | 2086.24 | 2086.24 | 29.0 | False | None | None | False | None | False | 60500.96 | 0 |
| 2960979 | 97875 | None | CODE325 | Double Arm Bracket with 1000mm Standard 40/50MM dia | Each | 3313.44 | 3313.44 | 2.0 | False | None | None | False | None | False | 6626.88 | 0 |
| 2960980 | 97875 | None | CODE326 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires.
Using 32mm dia G.I.Pipe | Each | 1282.42 | 1282.42 | 4.0 | False | None | None | False | None | False | 5129.68 | 0 |
| 2960981 | 97875 | None | CODE327 | Supply of LED Street light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source.
LED Streetlight 70 Watts | No | 7353.38 | 7353.38 | 17.0 | False | None | None | False | None | False | 125007.46 | 0 |
| 2960982 | 97875 | None | CODE328 | LED Streetlight 90 Watts | No | 10872.99 | 10872.99 | 13.0 | False | None | None | False | None | False | 141348.87 | 0 |
| 2960983 | 97875 | None | CODE329 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Floodlight 150W | No | 15327.73 | 15327.73 | 2.0 | False | None | None | False | None | False | 30655.46 | 0 |
| 2960984 | 97875 | None | CODE330 | Fixing halogen/metal/LED flood light fitting over existing pole including clamps, bolts, nuts, and wiring using suitable capacity wires | No | 198.81 | 198.81 | 32.0 | False | None | None | False | None | False | 6361.92 | 0 |
| 2960985 | 97875 | None | CODE331 | Supply of LED pole mounting type post top lantern with pressure diecast aluminium housing body for optimal thermal dissipation . Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs50000hr@Lumen Maintenance of 70%,CCT 5500K,IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains ,Surge Protection-Min 5KV along with Over voltage/ Overload, short circui / miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm .Universal Voltage driver to operate wide voltage range from 100Vto270V 50/60Hz application. Compliance to IS10322 /1EC60598, LM7 9& LM80 Adherence with RoHS. UL approved MCPCBLED Efficiency1301m/w, nominal CRI75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Developmen tfacility certified by ISO9001:2008. Housing with supplier word mark/ name shall be Engraved /Embossing on the diecasthousing /Body part Warranty of 2Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer &Cree /Nichia /Lumileds/Osrammake LED Source.
LED Post Top Lantern with 15/20 W | Each | 8494.68 | 8494.68 | 4.0 | False | None | None | False | None | False | 33978.72 | 0 |
| 2960986 | 97875 | None | CODE332 | Fixing charges of post top / Gate/ Garden fitting/ LED on the existing CI /GI or any other pipe using required size of reducer, wiring using suitable wires. | Each | 242.99 | 242.99 | 4.0 | False | None | None | False | None | False | 971.96 | 0 |
| 2960987 | 97875 | None | CODE333 | F) LIGHTNING PROTECTION SYSTEM : Air Terminal : Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) OBO Type No. RD 8/ALU (5450086) / equivalent | Mtr | 159.91 | 159.91 | 2200.0 | False | None | None | False | None | False | 351802.0 | 0 |
| 2960988 | 97875 | None | CODE334 | Supply of Roof conductor holder - Stainless steel Conductor holder for standing seaming type: Conductor holder @ 1 meter distance.Roof Conductor holder for 8/10 mm Folding Clamp in SS 304 OBO Type No. 272 5-20 SS 304(5450544 ) / equivalent | No | 335.53 | 335.53 | 2200.0 | False | None | None | False | None | False | 738166.0 | 0 |
| 2960989 | 97875 | None | CODE335 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561.
OBO type No.F-FIX JUNIOR (5403308) / equivalent | No | 1856.14 | 1856.14 | 1.0 | False | None | None | False | None | False | 1856.14 | 0 |
| 2960990 | 97875 | None | CODE336 | Providing of cross universal connector: For T and cross connection, to route vertical down conductor /mesh formation made of hot dipped galvanised iron with necessary screws etc as required. Installed with 4 hexagonal bolts M8*25 with M8 hexagonal nuts .
OBO Type No.253 S3 FT ( 5312592) / equivalent | No | 392.65 | 392.65 | 100.0 | False | None | None | False | None | False | 39265.0 | 0 |
| 2960991 | 97875 | None | CODE337 | Providing of expansion piece with connector: For equalising temperature related length changes. Necessary on conductors length over 20 meters. For round conductor Rd 8/ALU. OBO Type No. 172 AR ( 5218 92 6 ) / equivalent | No | 285.56 | 285.56 | 100.0 | False | None | None | False | None | False | 28556.0 | 0 |
| 2960992 | 97875 | None | CODE338 | Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Conforms to the requirements according to DIN VDE 0185-305 (IS-IEC 62305)(2No/expansion piece). OBO Type No. 249 B ST ( 5311705 ) / equivalent | No | 285.56 | 285.56 | 200.0 | False | None | None | False | None | False | 57112.0 | 0 |
| 2960993 | 97875 | None | CODE339 | Supply of Bridging cable: From flexible copper cable 16 mm², Coating: black, chlorinated India rubber mixture, With 1 mounting hole 10.5 mm per attachment side, With 2 mounting holes 7.3 mm per attachment side, For applications outside or inside suitable.
OBO Type No. 853 300 ( 5331013 ) / equivalent | No | 942.35 | 942.35 | 1.0 | False | None | None | False | None | False | 942.35 | 0 |
| 2960994 | 97875 | None | CODE340 | Supply of Clamping shoe: With 11 mm attaching hole, 2 hexagonal bolts M8 x 16, Bolts hot-dip galvanised steel and clamping element hot dipped galvanised cast steel
OBO Type No. 319 8 ( 5325307 ) / equivalent | No | 592.54 | 592.54 | 1.0 | False | None | None | False | None | False | 592.54 | 0 |
| 2960995 | 97875 | None | CODE341 | Down Conductor System : Supply of 8 mm Aluminum Round Conductor complete as specified in drawing & Meets the requirements of DIN EN 50164-2 (VDE 0185 part 202) & VDE 0185-305 (IS/IEC 62305) OBO Type No. RD 8/ALU (5450086) / equivalent | Mtr | 159.91 | 159.91 | 950.0 | False | None | None | False | None | False | 151914.5 | 0 |
| 2960996 | 97875 | None | CODE342 | Supply of Roof conductor holder - Stainless steel Conductor holder: With Bottom section and conductor holder stainless steel (V2A)Bottom section with 8.5 mm slot. Conductor holder @ 1 meter distance. OBO Type No. 159 VA-V (5217 07 5 ) / equivalent | No | 349.81 | 349.81 | 950.0 | False | None | None | False | None | False | 332319.5 | 0 |
| 2960997 | 97875 | None | CODE343 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer
OBO Type No. 271 8-10 ( 5317401 ) / equivalent | No | 746.88 | 746.88 | 42.0 | False | None | None | False | None | False | 31368.96 | 0 |
| 2960998 | 97875 | None | CODE344 | Earthing : Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. OBO Type No. 5052 DIN 30X3 ( 5450436 ) / equivalent | No | 306.98 | 306.98 | 100.0 | False | None | None | False | None | False | 30698.0 | 0 |
| 2960999 | 97875 | None | CODE345 | Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 No of hexagonal plate. OBO Type No. 256 S6 FT (5314572) / equivalent | No | 356.95 | 356.95 | 10.0 | False | None | None | False | None | False | 3569.5 | 0 |
| 2961000 | 97875 | None | CODE346 | Providing of flat conductor holder suitable for FL 30. Installed with 2 hexagonal bolts.
OBO Type No. 166 LS 70 ( 5226570 ) / equivalent | No | 385.51 | 385.51 | 42.0 | False | None | None | False | None | False | 16191.42 | 0 |
| 2961001 | 97875 | None | CODE347 | Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. OBO Type No.356 50 ( 2360 05 5 ) / equivalent | No | 1013.74 | 1013.74 | 5.0 | False | None | None | False | None | False | 5068.7 | 0 |
| 2961002 | 97875 | None | CODE348 | Supply of UL Listed & CPRI Tested maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 14mm with copper coating thickness of 250micron tested as per IEC 62561-2 . OBO Type No. 14 3000 CCER(5450010) / equivalent | No | 4854.52 | 4854.52 | 42.0 | False | None | None | False | None | False | 203889.84 | 0 |
| 2961003 | 97875 | None | CODE349 | Universal clamp made of SS to connect rod with flat conductor OBO Type No. 14 25 RTC(5450066) / equivalent | No | 1070.85 | 1070.85 | 42.0 | False | None | None | False | None | False | 44975.7 | 0 |
| 2961004 | 97875 | None | CODE350 | Earth conductivity enhancing compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested. OBO Type No. OEC 2 25(5450058) / equivalent | No | 3283.94 | 3283.94 | 42.0 | False | None | None | False | None | False | 137925.48 | 0 |
| 2961005 | 97875 | None | CODE351 | The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system . OBO Type No.UFE(5450030). / equivalent | No | 2712.82 | 2712.82 | 42.0 | False | None | None | False | None | False | 113938.44 | 0 |
| 2961006 | 97875 | None | CODE352 | G) EARTHING SYSTEM : Supplying, fixing and wiring earth electrode for grounding of Lifts, Transformers, DG sets etc., Using 40 mm dia 2.9mm thick 2.5mtrs long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a C.C. chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covereed 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | Each | 5222.96 | 5222.96 | 18.0 | False | None | None | False | None | False | 94013.28 | 0 |
| 2961007 | 97875 | None | CODE353 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required - 25x3mm GI strip | Mtr | 100.63 | 100.63 | 450.0 | False | None | None | False | None | False | 45283.5 | 0 |
| 2961008 | 97875 | None | CODE354 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required - 25 x 6 mm GI strip | Mtr | 157.08 | 157.08 | 100.0 | False | None | None | False | None | False | 15708.0 | 0 |
| 2961009 | 97875 | None | CODE355 | Supplying and running of GI strips for grounding connections, using necessary fixing materials as required - 8 SWG, GI Wire | Mtr | 27.98 | 27.98 | 200.0 | False | None | None | False | None | False | 5596.0 | 0 |
| 2961010 | 97875 | None | CODE356 | 600 x 600 x 3 mm GI Plate | Each | 9107.05 | 9107.05 | 2.0 | False | None | None | False | None | False | 18214.1 | 0 |
| 2961011 | 97875 | None | CODE357 | H) TELEPHONE SYSTEM : Supplying and fixing of modular switch/ Socket / telephone socket etc., on existing modular switch plate as per IS 3854 and IS 1293. - Telephone socket | Each | 191.44 | 191.44 | 54.0 | False | None | None | False | None | False | 10337.76 | 0 |
| 2961012 | 97875 | None | CODE358 | Supplying & drawing PVC flexible 2 pair telephone unarmoured tinned copper cable. | Mtr | 25.77 | 25.77 | 2000.0 | False | None | None | False | None | False | 51540.0 | 0 |
| 2961013 | 97875 | None | CODE359 | Supplying & Laying of 2mm thick, heavy guage PVC conduit pipe in the concealed slab / groove cutting with suitable size bNos, collars, clamps, metal junction boxes adhesive paste etc., and running before concreting the slabs. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes, and pipe Nos should be covered using PVC No closures and run with 18 SWG G.I fish wire run throughout the conduit wherever necessary - 20mm dia PVC Conduit - Supplying & laying | Mtr | 82.22 | 82.22 | 700.0 | False | None | None | False | None | False | 57554.0 | 0 |
| 2961014 | 97875 | None | CODE360 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.
5 pair cable - Supplying & laying | Mtr | 56.45 | 56.45 | 1250.0 | False | None | None | False | None | False | 70562.5 | 0 |
| 2961015 | 97875 | None | CODE361 | 10 pair cable - Supplying & laying | Mtr | 99.4 | 99.4 | 520.0 | False | None | None | False | None | False | 51688.0 | 0 |
| 2961016 | 97875 | None | CODE362 | 20 pair cable - Supplying & laying | Mtr | 184.08 | 184.08 | 50.0 | False | None | None | False | None | False | 9204.0 | 0 |
| 2961017 | 97875 | None | CODE363 | 50 pair cable - Supplying & laying | Mtr | 498.24 | 498.24 | 10.0 | False | None | None | False | None | False | 4982.4 | 0 |
| 2961018 | 97875 | None | CODE364 | 100 pair cable - Supplying & laying | Mtr | 1262.18 | 1262.18 | 10.0 | False | None | None | False | None | False | 12621.8 | 0 |
| 2961019 | 97875 | None | CODE365 | Supplying and fixing of MDF krone juntion box with KRONE module / Telephone cable termination.- 5 pair - Supplying & Fixing | No | 356.95 | 356.95 | 7.0 | False | None | None | False | None | False | 2498.65 | 0 |
| 2961020 | 97875 | None | CODE366 | 10 pair - Supplying & Fixing | No | 423.38 | 423.38 | 3.0 | False | None | None | False | None | False | 1270.14 | 0 |
| 2961021 | 97875 | None | CODE367 | 20 pair - Supplying & Fixing | No | 470.02 | 470.02 | 3.0 | False | None | None | False | None | False | 1410.06 | 0 |
| 2961022 | 97875 | None | CODE368 | 50 pair - Supplying & Fixing | No | 774.36 | 774.36 | 1.0 | False | None | None | False | None | False | 774.36 | 0 |
| 2961023 | 97875 | None | CODE369 | 100 pair - Supplying & Fixing | No | 1856.14 | 1856.14 | 1.0 | False | None | None | False | None | False | 1856.14 | 0 |
| 2961024 | 97875 | None | CODE370 | Supply and installing of 100 X 100 pair (duplicate) Disconnect type with fuse protection (for incoming DOT lines) for main distribution frame for terminating EPABX side & building internal telephone wiring. | No | 15705.8 | 15705.8 | 1.0 | False | None | None | False | None | False | 15705.8 | 0 |
| 2961025 | 97875 | None | CODE371 | I) DATA SYSTEM : Supplying & Laying of 2mm thick, heavy guage PVC conduit pipe in the concealed slab / groove cutting with suitable size bNos, collars, clamps, metal junction boxes adhesive paste etc., and running before concreting the slabs. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes, and pipe Nos should be covered using PVC No closures and run with 18 SWG G.I fish wire run throughout the conduit wherever necessary - 20mm dia PVC Conduit - Supplying & laying | Mtr | 82.22 | 82.22 | 100.0 | False | None | None | False | None | False | 8222.0 | 0 |
| 2961026 | 97875 | None | CODE372 | 25mm dia PVC Conduit - Supplying & laying | Mtr | 96.34 | 96.34 | 500.0 | False | None | None | False | None | False | 48170.0 | 0 |
| 2961027 | 97875 | None | CODE373 | Supplying and fixing of modular Socket on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O outlet | Each | 413.57 | 413.57 | 60.0 | False | None | None | False | None | False | 24814.2 | 0 |
| 2961028 | 97875 | None | CODE374 | Supplying and drawing UTP -CAT 6E LAN cable | Mtr | 46.63 | 46.63 | 1600.0 | False | None | None | False | None | False | 74608.0 | 0 |
| 2961029 | 97875 | None | CODE375 | Supply, installation , testing & commissioning of managed L2 24 port switch of 10/100/1000 Mbps with 2 Gig SFP. The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing No termination. | No | 50867.44 | 50867.44 | 4.0 | False | None | None | False | None | False | 203469.76 | 0 |
| 2961030 | 97875 | None | CODE376 | Supply, installation , testing & commissioning of managed L2 24 port POE switch of 10/100/1000 Mbps with 2 Gig SFP. & power budget of min. 360W. The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing No termination. | No | 117079.6 | 117079.6 | 3.0 | False | None | None | False | None | False | 351238.8 | 0 |
| 2961031 | 97875 | None | CODE377 | Supply, installation , testing & commissioning of managed L2 12 port POE switch of 10/100/1000 Mbps with 2 Gig SFP. & power budget of min. 170W. The switch shall be mounted on existing rack. The rate shall also include cost of power supply and providing No termination. | No | 59253.7 | 59253.7 | 5.0 | False | None | None | False | None | False | 296268.5 | 0 |
| 2961032 | 97875 | None | CODE378 | Supply, installation, testing and commissioning of L3 managed switch with 12port 10/100/1000 Mbps, 12 Gig SFP ports. The switch shall be mounted on existing rack. The rate shall include 2No. exhaust air flow fan, dual PSU, Full L3 license , providing No termination. | No | 471174.0 | 471174.0 | 1.0 | False | None | None | False | None | False | 471174.0 | 0 |
| 2961033 | 97875 | None | CODE379 | Supply and fixing of patch panel with CAT-6 I/O mounted on existing rack with all necessary fixing accessories. The rate shall also include providing No termination. 24 port 10/100/1000 patch panel | No | 9694.88 | 9694.88 | 9.0 | False | None | None | False | None | False | 87253.92 | 0 |
| 2961034 | 97875 | None | CODE380 | Supply, installation , testing & commissioning of SFP Transceiver 1000BASE-LR SINGLE MODE LC GBIC | No | 22844.8 | 22844.8 | 22.0 | False | None | None | False | None | False | 502585.6 | 0 |
| 2961035 | 97875 | None | CODE381 | Supply and fixing of …mtrs cat 6 patch cable- 1 mtr | Mtr | 274.89 | 274.89 | 60.0 | False | None | None | False | None | False | 16493.4 | 0 |
| 2961036 | 97875 | None | CODE382 | Supply and fixing of …mtrs cat 6 patch cable- 2 mtr | Mtr | 315.39 | 315.39 | 60.0 | False | None | None | False | None | False | 18923.4 | 0 |
| 2961037 | 97875 | None | CODE383 | OS2 SC-LC single mode duplex fiber optic Patch Cord 3Mtrs | No | 3355.33 | 3355.33 | 22.0 | False | None | None | False | None | False | 73817.26 | 0 |
| 2961038 | 97875 | None | CODE384 | Supply and installation of rack mount LIU loaded with couplers and all necessary accessories. -6 fibre SC style single mode Fiber Panel loaded with Splice Tray, Adapters & Pigtails- 1U | No | 9994.6 | 9994.6 | 9.0 | False | None | None | False | None | False | 89951.4 | 0 |
| 2961039 | 97875 | None | CODE385 | 24 fibre SC style single mode Fiber Panel loaded with Splice Tray, Adapters & Pigtails- 1U | No | 34267.2 | 34267.2 | 3.0 | False | None | None | False | None | False | 102801.6 | 0 |
| 2961040 | 97875 | None | CODE386 | Supply, laying and testing of Optical fiber cable, the rate shall include the cost of joint enclosure and splicing of Optical Fiber cables. - 6 Core single mode OS2 corrugated steel tape armoured loose tube gell- filled, 9/125 micron fiber optic cable. | Mtr | 104.23 | 104.23 | 1500.0 | False | None | None | False | None | False | 156345.0 | 0 |
| 2961041 | 97875 | None | CODE387 | Supply and fixing of switch wall mounting closed rack with power manager and cable manager - 12U with 450mm depth with all necrssary accessories as required. | No | 20203.39 | 20203.39 | 2.0 | False | None | None | False | None | False | 40406.78 | 0 |
| 2961042 | 97875 | None | CODE388 | Supply and fixing of switch wall mounting closed rack with power manager and cable manager - 9U with 450mm depth with all necrssary accessories as required. | No | 16718.15 | 16718.15 | 7.0 | False | None | None | False | None | False | 117027.05 | 0 |
| 2961043 | 97875 | None | CODE389 | Supply and fixing of switch floor mounting closed rack with power manager and cable manager - 42U with 800mm depth with all necrssary accessories as required. | No | 81996.6 | 81996.6 | 1.0 | False | None | None | False | None | False | 81996.6 | 0 |
| 2961044 | 97875 | None | CODE390 | J. 3 IP CCTV SYSTEM : Supplying Laying of 2mm thick, heavy guage PVC conduit pipe in the concealed slab / groove cutting with suitable size bNos, collars, clamps, metal junction boxes adhesive paste etc., and running before concreting the slabs. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes, and pipe Nos should be covered using PVC No closures and run with 14 SWG G.I fish wire run throughout the conduit wherever necessary 20mm dia PVC Conduit Supplying & laying | Mtr | 82.22 | 82.22 | 200.0 | False | None | None | False | None | False | 16444.0 | 0 |
| 2961045 | 97875 | None | CODE391 | 25mm dia PVC Conduit - Supplying & laying | Mtr | 96.34 | 96.34 | 600.0 | False | None | None | False | None | False | 57804.0 | 0 |
| 2961046 | 97875 | None | CODE392 | Supplying, drawing and connecting of 1 pair E - Cat-6 cable in 25mm dia PVC conduit with all other accessories. | Mtr | 46.63 | 46.63 | 1500.0 | False | None | None | False | None | False | 69945.0 | 0 |
| 2961047 | 97875 | None | CODE393 | Supply, installation, testing and commissioning of outdoor 2.0MP IP IR Bullet WDR, 2.7-12mm varifocal Color Camera, 1/3" CMOS, H.264/MJPEG High-profile, dual Stream support, True Day & Night (TDN) with , Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G - TF card support (128 GB), IP66 Rating, Power Over Ethernet (POE), IR distance upto 30 Meter depNoing on scene reflectance. | No | 7788.0 | 7788.0 | 50.0 | False | None | None | False | None | False | 389400.0 | 0 |
| 2961048 | 97875 | None | CODE394 | Supply, installation, testing and commissioning of outdoor 2.0MP IP IR Minidome, WDR, 2.7-12mm varifocal Color dome Camera, 1/3" CMOS, H.264/MJPEG High-profile, dual Stream support, True Day & Night (TDN) with , Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G - TF card support (128 GB), IP66 & IK 10 Rating, Power Over Ethernet (POE), IR distance upto 30 Meter depNoing on scene reflectance. | No | 7788.0 | 7788.0 | 4.0 | False | None | None | False | None | False | 31152.0 | 0 |
| 2961049 | 97875 | None | CODE395 | Supply and fixing of …mtrs cat 6 patch cable- 1 mtr | Mtr | 274.89 | 274.89 | 54.0 | False | None | None | False | None | False | 14844.06 | 0 |
| 2961050 | 97875 | None | CODE396 | Supply, installation, testing and commissioning of network video recorder Supporting up to 32 IP Camera Streams with 8TB HDD, shall support windows platform, warning system alerts for fan fault, HDD temp, No HDD detected, HDD full, MPEG4 Compression / decompression with configurable video quality, Network Health and Event Monitoring Support Through Simple Network Management Protocol (SNMP) and New Digital Sentry System Information (DSSI) Utility TCP/IP ready for remote monitoring, data should be achieved to USB drive, Alarm and motion activated recording, 2 Gigabit Ethernet RJ-45 (1000Base-T) interface, the rate shall include monitoring Software, 2 user liscence, camera license,and HDD. VNoor to quote all necessary components as required to complete the system | No | 61395.4 | 61395.4 | 2.0 | False | None | None | False | None | False | 122790.8 | 0 |
| 2961051 | 97875 | None | CODE397 | MISCELLANEOUS WORKS: Supply & laying of 2 mm thick, PVC conduit with all conduit accessories etc., as required. The rate shall include chasing of walls / floors and plastering the chased portion as required 20mm dia PVC Conduit | Mtr | 82.22 | 82.22 | 200.0 | False | None | None | False | None | False | 16444.0 | 0 |
| 2961052 | 97875 | None | CODE398 | 25mm dia PVC Conduit | Mtr | 96.34 | 96.34 | 100.0 | False | None | None | False | None | False | 9634.0 | 0 |
| 2961053 | 97875 | None | CODE399 | 32mm dia PVC Conduit | Mtr | 123.95 | 123.95 | 100.0 | False | None | None | False | None | False | 12395.0 | 0 |
| 2961054 | 97875 | None | CODE400 | Constructing brick masonry inspection chamber 455x610mm, and 450mm depth, (clear inside dimension) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I. cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 Kg (Weight of cover 23Kg and weight of frame 15Kg) R.C.C. top slab with cement concrete 1:2:4 mix 20mm and downsize granite metal, foundation concrete 1:5:10 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. a) 455X610X450 | No | 6923.86 | 6923.86 | 10.0 | False | None | None | False | None | False | 69238.6 | 0 |
| 2961055 | 97875 | None | CODE401 | b) 455X610X450 - 750 | No | 9295.55 | 9295.55 | 10.0 | False | None | None | False | None | False | 92955.5 | 0 |
| 2961056 | 97875 | None | CODE402 | c) 500X700X450 -750 | No | 10289.58 | 10289.58 | 2.0 | False | None | None | False | None | False | 20579.16 | 0 |
| 2961057 | 97875 | None | CODE403 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. | No | 571.12 | 571.12 | 30.0 | False | None | None | False | None | False | 17133.6 | 0 |
| 2961058 | 97875 | None | CODE404 | Supply & Laying of rubber mats of 11kv grade, 1.8.mtr. x 0.9mtr X 2.5mm (thick) and of sufficient thickness as required by the Electrical Inspectorate and confirming to IS 15652 | No | 2855.6 | 2855.6 | 5.0 | False | None | None | False | None | False | 14278.0 | 0 |
| 2961059 | 97875 | None | CODE405 | Providing rubber gloves of electrical quality tested to 11 KV. | Set | 324.5 | 324.5 | 2.0 | False | None | None | False | None | False | 649.0 | 0 |
| 2961060 | 97875 | None | CODE406 | Fixing of first Aid box containing medicines for 50 persons to give first aid treatment. | No | 389.4 | 389.4 | 5.0 | False | None | None | False | None | False | 1947.0 | 0 |
| 2961061 | 97875 | None | CODE407 | Supply and fixing in position approved shock treatment chart written in English, Hindi and local language. The chart shall be framed in teakwood frame and covered with glass. | No | 944.94 | 944.94 | 1.0 | False | None | None | False | None | False | 944.94 | 0 |
| 2961062 | 97875 | None | CODE408 | Supply & Fixing of DANGER / NO ADDMISSION. / NO SMOKING / Board made out of MS sheet metal with 2 coats of non-corrosive enamelled paint of approved shape and size as specified by local electrical authorities written in English, Hindi and local language. | No | 356.36 | 356.36 | 1.0 | False | None | None | False | None | False | 356.36 | 0 |
| 2961063 | 97875 | None | CODE409 | Supply, installation, testing and commissioning of 3- phase input to 3- phase output 1 x 15.0 kVA, ONLINE, UPS. | Set | 197036.4 | 197036.4 | 1.0 | False | None | None | False | None | False | 197036.4 | 0 |
| 2961064 | 97875 | None | CODE410 | Supply, installation, testing and commissioning of SMF batteries for 1 x 15.0 kVA, ONLINE, UPS with 90 min back up. The rate shall include cost of battery, battery rack, cables and necessary accessories as required | Set | 354094.4 | 354094.4 | 1.0 | False | None | None | False | None | False | 354094.4 | 0 |