tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1709805442000 | 0 | None | None | Buildings | Civil - Ground Floor | 88420719.46 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957274 | 97751 | None | Code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 510.11 | 510.11 | 31.3 | False | None | None | False | None | False | 15966.443 | 0 | 2957275 | 97751 | None | Code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 123.31 | 123.31 | 938.91 | False | None | None | False | None | False | 115776.9921 | 0 | 2957276 | 97751 | None | Code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 132.4 | 132.4 | 3071.56 | False | None | None | False | None | False | 406674.544 | 0 | 2957277 | 97751 | None | Code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 471.17 | 471.17 | 572.38 | False | None | None | False | None | False | 269688.2846 | 0 | 2957278 | 97751 | None | Code05 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 551.65 | 551.65 | 190.79 | False | None | None | False | None | False | 105249.3035 | 0 | 2957279 | 97751 | None | Code06 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 175.23 | 175.23 | 200.0 | False | None | None | False | None | False | 35046.0 | 0 | 2957280 | 97751 | None | Code07 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under
and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 153.16 | 153.16 | 2063.0 | False | None | None | False | None | False | 315969.08 | 0 | 2957281 | 97751 | None | Code08 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 345.27 | 345.27 | 3076.27 | False | None | None | False | None | False | 1062143.7429 | 0 | 2957282 | 97751 | None | Code09 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 615.25 | 615.25 | 743.65 | False | None | None | False | None | False | 457530.6625 | 0 | 2957283 | 97751 | None | Code10 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 7773.72 | 7773.72 | 814.49 | False | None | None | False | None | False | 6331617.2028 | 0 | 2957284 | 97751 | None | Code11 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork - FOOTINGS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 8470.85 | 8470.85 | 1500.18 | False | None | None | False | None | False | 12707799.753 | 0 | 2957285 | 97751 | None | Code12 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Including FormWork - PEDESTALS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 9046.54 | 9046.54 | 24.02 | False | None | None | False | None | False | 217297.8908 | 0 | 2957286 | 97751 | None | Code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - COLUMNS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15099.76 | 15099.76 | 125.06 | False | None | None | False | None | False | 1888375.9856 | 0 | 2957287 | 97751 | None | Code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LIFT CORE WALL ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15099.76 | 15099.76 | 38.56 | False | None | None | False | None | False | 582246.7456 | 0 | 2957288 | 97751 | None | Code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - CURTAIN WALL ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13323.32 | 13323.32 | 54.82 | False | None | None | False | None | False | 730384.4024 | 0 | 2957289 | 97751 | None | Code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - PLINTH BEAM ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13323.32 | 13323.32 | 101.61 | False | None | None | False | None | False | 1353782.5452 | 0 | 2957290 | 97751 | None | Code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC BEAMS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14211.54 | 14211.54 | 220.33 | False | None | None | False | None | False | 3131228.6082 | 0 | 2957291 | 97751 | None | Code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC SLAB ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13323.32 | 13323.32 | 271.61 | False | None | None | False | None | False | 3618746.9452 | 0 | 2957292 | 97751 | None | Code19 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC STAIRCASE ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13323.32 | 13323.32 | 34.94 | False | None | None | False | None | False | 465516.8008 | 0 | 2957293 | 97751 | None | Code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LINTELS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14211.54 | 14211.54 | 10.51 | False | None | None | False | None | False | 149363.2854 | 0 | 2957294 | 97751 | None | Code21 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12478.32 | 12478.32 | 12.07 | False | None | None | False | None | False | 150613.3224 | 0 | 2957295 | 97751 | None | Code22 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1606.92 | 1606.92 | 28.04 | False | None | None | False | None | False | 45058.0368 | 0 | 2957296 | 97751 | None | Code23 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 116115.19 | 116115.19 | 237.65 | False | None | None | False | None | False | 27594774.9035 | 0 | 2957297 | 97751 | None | Code24 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 38.94 | 38.94 | 222.6 | False | None | None | False | None | False | 8668.044 | 0 | 2957298 | 97751 | None | Code25 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 86.14 | 86.14 | 222.6 | False | None | None | False | None | False | 19174.764 | 0 | 2957299 | 97751 | None | Code26 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 8292.92 | 8292.92 | 36.36 | False | None | None | False | None | False | 301530.5712 | 0 | 2957300 | 97751 | None | Code27 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1700.38 | 1700.38 | 2278.5 | False | None | None | False | None | False | 3874315.83 | 0 | 2957301 | 97751 | None | Code28 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1432.99 | 1432.99 | 311.85 | False | None | None | False | None | False | 446877.9315 | 0 | 2957302 | 97751 | None | Code29 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc. to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 6129.16 | 6129.16 | 9.6 | False | None | None | False | None | False | 58839.936 | 0 | 2957303 | 97751 | None | Code30 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 128261.87 | 128261.87 | 2.49 | False | None | None | False | None | False | 319372.0563 | 0 | 2957304 | 97751 | None | Code31 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1318.77 | 1318.77 | 48.0 | False | None | None | False | None | False | 63300.96 | 0 | 2957305 | 97751 | None | Code32 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 713.9 | 713.9 | 96.0 | False | None | None | False | None | False | 68534.4 | 0 | 2957306 | 97751 | None | Code33 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 486.75 | 486.75 | 48.0 | False | None | None | False | None | False | 23364.0 | 0 | 2957307 | 97751 | None | Code34 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 194.7 | 194.7 | 96.0 | False | None | None | False | None | False | 18691.2 | 0 | 2957308 | 97751 | None | Code35 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 90.86 | 90.86 | 192.0 | False | None | None | False | None | False | 17445.12 | 0 | 2957309 | 97751 | None | Code36 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 129.8 | 129.8 | 48.0 | False | None | None | False | None | False | 6230.4 | 0 | 2957310 | 97751 | None | Code37 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1365.5 | 1365.5 | 48.0 | False | None | None | False | None | False | 65544.0 | 0 | 2957311 | 97751 | None | Code38 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 77.88 | 77.88 | 288.0 | False | None | None | False | None | False | 22429.44 | 0 | 2957312 | 97751 | None | Code39 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 67.5 | 67.5 | 303.6 | False | None | None | False | None | False | 20493.0 | 0 | 2957313 | 97751 | None | Code40 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4311.96 | 4311.96 | 175.68 | False | None | None | False | None | False | 757525.1328 | 0 | 2957314 | 97751 | None | Code41 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 8740.73 | 8740.73 | 108.24 | False | None | None | False | None | False | 946096.6152 | 0 | 2957315 | 97751 | None | Code42 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7423.26 | 7423.26 | 15.54 | False | None | None | False | None | False | 115357.4604 | 0 | 2957316 | 97751 | None | Code43 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 218.06 | 218.06 | 2599.38 | False | None | None | False | None | False | 566820.8028 | 0 | 2957317 | 97751 | None | Code44 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 911.2 | 911.2 | 16.27 | False | None | None | False | None | False | 14825.224 | 0 | 2957318 | 97751 | None | Code45 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4523.53 | 4523.53 | 61.11 | False | None | None | False | None | False | 276432.9183 | 0 | 2957319 | 97751 | None | Code46 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1445.97 | 1445.97 | 81.0 | False | None | None | False | None | False | 117123.57 | 0 | 2957320 | 97751 | None | Code47 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kgs | 176.53 | 176.53 | 504.0 | False | None | None | False | None | False | 88971.12 | 0 | 2957321 | 97751 | None | Code48 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 404.98 | 404.98 | 2482.8 | False | None | None | False | None | False | 1005484.344 | 0 | 2957322 | 97751 | None | Code49 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 273.88 | 273.88 | 2864.78 | False | None | None | False | None | False | 784605.9464 | 0 | 2957323 | 97751 | None | Code50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 129.8 | 129.8 | 5347.58 | False | None | None | False | None | False | 694115.884 | 0 | 2957324 | 97751 | None | Code51 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 453.0 | 453.0 | 931.56 | False | None | None | False | None | False | 421996.68 | 0 | 2957325 | 97751 | None | Code52 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 459.49 | 459.49 | 203.03 | False | None | None | False | None | False | 93290.2547 | 0 | 2957326 | 97751 | None | Code53 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 49.32 | 49.32 | 4200.0 | False | None | None | False | None | False | 207144.0 | 0 | 2957327 | 97751 | None | Code54 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 2957328 | 97751 | None | Code55 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 67.5 | 67.5 | 1144.0 | False | None | None | False | None | False | 77220.0 | 0 | 2957329 | 97751 | None | Code56 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1525.15 | 1525.15 | 1690.87 | False | None | None | False | None | False | 2578830.3805 | 0 | 2957330 | 97751 | None | Code57 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 585.4 | 585.4 | 88.92 | False | None | None | False | None | False | 52053.768 | 0 | 2957331 | 97751 | None | Code58 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1721.15 | 1721.15 | 1595.1 | False | None | None | False | None | False | 2745406.365 | 0 | 2957332 | 97751 | None | Code59 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 6915.74 | 6915.74 | 314.64 | False | None | None | False | None | False | 2175968.4336 | 0 | 2957333 | 97751 | None | Code60 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 3351.44 | 3351.44 | 114.41 | False | None | None | False | None | False | 383438.2504 | 0 | 2957334 | 97751 | None | Code61 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 382.91 | 382.91 | 2074.47 | False | None | None | False | None | False | 794335.3077 | 0 | 2957335 | 97751 | None | Code62 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 798.27 | 798.27 | 180.37 | False | None | None | False | None | False | 143983.9599 | 0 | 2957336 | 97751 | None | Code63 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1153.92 | 1153.92 | 112.81 | False | None | None | False | None | False | 130173.7152 | 0 | 2957337 | 97751 | None | Code64 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1880.8 | 1880.8 | 479.37 | False | None | None | False | None | False | 901599.096 | 0 | 2957338 | 97751 | None | Code65 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 733.37 | 733.37 | 629.16 | False | None | None | False | None | False | 461407.0692 | 0 | 2957339 | 97751 | None | Code66 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 164.85 | 164.85 | 5347.58 | False | None | None | False | None | False | 881548.563 | 0 | 2957340 | 97751 | None | Code67 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 202.49 | 202.49 | 931.56 | False | None | None | False | None | False | 188631.5844 | 0 | 2957341 | 97751 | None | Code68 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 64.9 | 64.9 | 123.78 | False | None | None | False | None | False | 8033.322 | 0 | 2957342 | 97751 | None | Code69 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 149.27 | 149.27 | 123.78 | False | None | None | False | None | False | 18476.6406 | 0 | 2957343 | 97751 | None | Code70 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 68.79 | 68.79 | 421.63 | False | None | None | False | None | False | 29003.9277 | 0 | 2957344 | 97751 | None | Code71 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 878.75 | 878.75 | 421.63 | False | None | None | False | None | False | 370507.3625 | 0 | 2957345 | 97751 | None | Code72 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 528.29 | 528.29 | 627.9 | False | None | None | False | None | False | 331713.291 | 0 | 2957346 | 97751 | None | Code73 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 3949.81 | 3949.81 | 69.0 | False | None | None | False | None | False | 272536.89 | 0 | 2957347 | 97751 | None | Code74 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5397.08 | 5397.08 | 27.6 | False | None | None | False | None | False | 148959.408 | 0 | 2957348 | 97751 | None | Code75 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1653.65 | 1653.65 | 348.47 | False | None | None | False | None | False | 576247.4155 | 0 | 2957349 | 97751 | None | Code76 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2197.51 | 2197.51 | 522.71 | False | None | None | False | None | False | 1148660.4521 | 0 | 2957350 | 97751 | None | Code77 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5199.79 | 5199.79 | 60.0 | False | None | None | False | None | False | 311987.4 | 0 | 2957351 | 97751 | None | Code78 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2596.0 | 2596.0 | 120.0 | False | None | None | False | None | False | 311520.0 | 0 | 2957352 | 97751 | None | Code79 | Providing and fixing fire resistant door frame of section 143 x 57 mm having built in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size 10x4 mm (minimum) alround the frame and fixing with dash fastener of approved size and make, including applying a coat of approved brand fire resistant primer etc. complete as per direction of Engineer-in-charge (Dash fastener to bepaid for separately). ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1541.11 | 1541.11 | 48.0 | False | None | None | False | None | False | 73973.28 | 0 | 2957353 | 97751 | None | Code80 | Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made out of 16 SWG G.I.sheet (zinc coating not less than 120 gm/m2) duly filled FR insulation material and fixing with necessary stainless steel ball bearing hinges of approved make, including applying a coat of approved fire resistant primer etc. all complete as per direction of Engineer-in-charge (panneling to be paid for separately). ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 6790.22 | 6790.22 | 16.92 | False | None | None | False | None | False | 114890.5224 | 0 |
| 1709805442000 | 0 | None | None | Buildings | Civil First Floor | 46200535.62 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957354 | 97752 | None | Code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - COLUMNS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15250.76 | 15250.76 | 97.27 | False | None | None | False | None | False | 1483441.4252 | 0 | 2957355 | 97752 | None | Code02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LIFT CORE WALL ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15250.76 | 15250.76 | 29.99 | False | None | None | False | None | False | 457370.2924 | 0 | 2957356 | 97752 | None | Code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC BEAMS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14353.66 | 14353.66 | 209.81 | False | None | None | False | None | False | 3011541.4046 | 0 | 2957357 | 97752 | None | Code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork -RCC SLAB ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13456.55 | 13456.55 | 253.25 | False | None | None | False | None | False | 3407871.2875 | 0 | 2957358 | 97752 | None | Code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork -Staircase 1 2 3 4 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13456.55 | 13456.55 | 34.11 | False | None | None | False | None | False | 459002.9205 | 0 | 2957359 | 97752 | None | Code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LINTELS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14353.66 | 14353.66 | 11.17 | False | None | None | False | None | False | 160330.3822 | 0 | 2957360 | 97752 | None | Code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12603.11 | 12603.11 | 9.59 | False | None | None | False | None | False | 120863.8249 | 0 | 2957361 | 97752 | None | Code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 117276.34 | 117276.34 | 99.93 | False | None | None | False | None | False | 11719424.6562 | 0 | 2957362 | 97752 | None | Code09 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 38.94 | 38.94 | 234.1 | False | None | None | False | None | False | 9115.854 | 0 | 2957363 | 97752 | None | Code10 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 86.14 | 86.14 | 234.1 | False | None | None | False | None | False | 20165.374 | 0 | 2957364 | 97752 | None | Code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1717.38 | 1717.38 | 2283.84 | False | None | None | False | None | False | 3922221.1392 | 0 | 2957365 | 97752 | None | Code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1447.32 | 1447.32 | 388.04 | False | None | None | False | None | False | 561618.0528 | 0 | 2957366 | 97752 | None | Code13 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 129544.49 | 129544.49 | 2.75 | False | None | None | False | None | False | 356247.3475 | 0 | 2957367 | 97752 | None | Code14 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1331.96 | 1331.96 | 54.0 | False | None | None | False | None | False | 71925.84 | 0 | 2957368 | 97752 | None | Code15 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 721.04 | 721.04 | 108.0 | False | None | None | False | None | False | 77872.32 | 0 | 2957369 | 97752 | None | Code16 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 491.62 | 491.62 | 54.0 | False | None | None | False | None | False | 26547.48 | 0 | 2957370 | 97752 | None | Code17 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 196.65 | 196.65 | 91.0 | False | None | None | False | None | False | 17895.15 | 0 | 2957371 | 97752 | None | Code18 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 91.77 | 91.77 | 179.0 | False | None | None | False | None | False | 16426.83 | 0 | 2957372 | 97752 | None | Code19 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 131.1 | 131.1 | 54.0 | False | None | None | False | None | False | 7079.4 | 0 | 2957373 | 97752 | None | Code20 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1379.15 | 1379.15 | 54.0 | False | None | None | False | None | False | 74474.1 | 0 | 2957374 | 97752 | None | Code21 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 78.66 | 78.66 | 324.0 | False | None | None | False | None | False | 25485.84 | 0 | 2957375 | 97752 | None | Code22 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 68.17 | 68.17 | 334.5 | False | None | None | False | None | False | 22802.865 | 0 | 2957376 | 97752 | None | Code23 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4355.08 | 4355.08 | 180.72 | False | None | None | False | None | False | 787050.0576 | 0 | 2957377 | 97752 | None | Code24 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 8828.14 | 8828.14 | 98.16 | False | None | None | False | None | False | 866570.2224 | 0 | 2957378 | 97752 | None | Code25 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7497.49 | 7497.49 | 42.48 | False | None | None | False | None | False | 318493.3752 | 0 | 2957379 | 97752 | None | Code26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 220.24 | 220.24 | 2953.44 | False | None | None | False | None | False | 650465.6256 | 0 | 2957380 | 97752 | None | Code27 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 920.31 | 920.31 | 22.68 | False | None | None | False | None | False | 20872.6308 | 0 | 2957381 | 97752 | None | Code28 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4568.77 | 4568.77 | 85.37 | False | None | None | False | None | False | 390035.8949 | 0 | 2957382 | 97752 | None | Code29 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1460.43 | 1460.43 | 100.0 | False | None | None | False | None | False | 146043.0 | 0 | 2957383 | 97752 | None | Code30 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 409.03 | 409.03 | 2644.14 | False | None | None | False | None | False | 1081532.5842 | 0 | 2957384 | 97752 | None | Code31 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 276.62 | 276.62 | 2664.89 | False | None | None | False | None | False | 737161.8718 | 0 | 2957385 | 97752 | None | Code32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 131.1 | 131.1 | 5309.03 | False | None | None | False | None | False | 696013.833 | 0 | 2957386 | 97752 | None | Code33 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 457.53 | 457.53 | 926.64 | False | None | None | False | None | False | 423965.5992 | 0 | 2957387 | 97752 | None | Code34 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 464.09 | 464.09 | 194.75 | False | None | None | False | None | False | 90381.5275 | 0 | 2957388 | 97752 | None | Code35 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 49.82 | 49.82 | 1245.4 | False | None | None | False | None | False | 62045.828 | 0 | 2957389 | 97752 | None | Code36 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 2644.25 | 2644.25 | 41.15 | False | None | None | False | None | False | 108810.8875 | 0 | 2957390 | 97752 | None | Code37 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 806.25 | 806.25 | 220.16 | False | None | None | False | None | False | 177504.0 | 0 | 2957391 | 97752 | None | Code38 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 2957392 | 97752 | None | Code39 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 68.17 | 68.17 | 1118.0 | False | None | None | False | None | False | 76214.06 | 0 | 2957393 | 97752 | None | Code40 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1540.4 | 1540.4 | 1421.51 | False | None | None | False | None | False | 2189694.004 | 0 | 2957394 | 97752 | None | Code41 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1738.36 | 1738.36 | 1616.78 | False | None | None | False | None | False | 2810545.6808 | 0 | 2957395 | 97752 | None | Code42 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 6984.9 | 6984.9 | 188.64 | False | None | None | False | None | False | 1317631.536 | 0 | 2957396 | 97752 | None | Code43 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 386.74 | 386.74 | 2183.06 | False | None | None | False | None | False | 844276.6244 | 0 | 2957397 | 97752 | None | Code44 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1165.46 | 1165.46 | 137.18 | False | None | None | False | None | False | 159877.8028 | 0 | 2957398 | 97752 | None | Code45 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1899.61 | 1899.61 | 566.28 | False | None | None | False | None | False | 1075711.1508 | 0 | 2957399 | 97752 | None | Code46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 740.7 | 740.7 | 452.76 | False | None | None | False | None | False | 335359.332 | 0 | 2957400 | 97752 | None | Code47 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 166.49 | 166.49 | 5309.03 | False | None | None | False | None | False | 883900.4047 | 0 | 2957401 | 97752 | None | Code48 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 204.51 | 204.51 | 926.64 | False | None | None | False | None | False | 189507.1464 | 0 | 2957402 | 97752 | None | Code49 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 65.55 | 65.55 | 140.64 | False | None | None | False | None | False | 9218.952 | 0 | 2957403 | 97752 | None | Code50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 150.76 | 150.76 | 140.64 | False | None | None | False | None | False | 21202.8864 | 0 | 2957404 | 97752 | None | Code51 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 69.48 | 69.48 | 433.73 | False | None | None | False | None | False | 30135.5604 | 0 | 2957405 | 97752 | None | Code52 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 887.53 | 887.53 | 433.73 | False | None | None | False | None | False | 384948.3869 | 0 | 2957406 | 97752 | None | Code53 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 533.57 | 533.57 | 849.03 | False | None | None | False | None | False | 453016.9371 | 0 | 2957407 | 97752 | None | Code54 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 3989.31 | 3989.31 | 130.62 | False | None | None | False | None | False | 521083.6722 | 0 | 2957408 | 97752 | None | Code55 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5451.05 | 5451.05 | 37.32 | False | None | None | False | None | False | 203433.186 | 0 | 2957409 | 97752 | None | Code56 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1670.19 | 1670.19 | 277.92 | False | None | None | False | None | False | 464179.2048 | 0 | 2957410 | 97752 | None | Code57 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2219.49 | 2219.49 | 416.88 | False | None | None | False | None | False | 925260.9912 | 0 | 2957411 | 97752 | None | Code58 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5251.79 | 5251.79 | 60.0 | False | None | None | False | None | False | 315107.4 | 0 | 2957412 | 97752 | None | Code59 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 |
| 1709805442000 | 0 | None | None | Buildings | Civil Second Floor | 41834527.54 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957413 | 97753 | None | Code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - COLUMNS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15401.76 | 15401.76 | 97.27 | False | None | None | False | None | False | 1498129.1952 | 0 | 2957414 | 97753 | None | Code02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LIFT CORE WALL ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15401.76 | 15401.76 | 29.99 | False | None | None | False | None | False | 461898.7824 | 0 | 2957415 | 97753 | None | Code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC BEAMS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14495.77 | 14495.77 | 211.73 | False | None | None | False | None | False | 3069189.3821 | 0 | 2957416 | 97753 | None | Code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC SLAB ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13589.79 | 13589.79 | 250.93 | False | None | None | False | None | False | 3410086.0047 | 0 | 2957417 | 97753 | None | Code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - Staircase 1 2 3 4 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13589.79 | 13589.79 | 34.11 | False | None | None | False | None | False | 463547.7369 | 0 | 2957418 | 97753 | None | Code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LINTELS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14495.77 | 14495.77 | 9.63 | False | None | None | False | None | False | 139594.2651 | 0 | 2957419 | 97753 | None | Code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12727.89 | 12727.89 | 9.58 | False | None | None | False | None | False | 121933.1862 | 0 | 2957420 | 97753 | None | Code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 118437.49 | 118437.49 | 95.02 | False | None | None | False | None | False | 11253930.2998 | 0 | 2957421 | 97753 | None | Code09 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 38.94 | 38.94 | 229.2 | False | None | None | False | None | False | 8925.048 | 0 | 2957422 | 97753 | None | Code10 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 86.14 | 86.14 | 229.2 | False | None | None | False | None | False | 19743.288 | 0 | 2957423 | 97753 | None | Code11 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1734.39 | 1734.39 | 1961.28 | False | None | None | False | None | False | 3401624.4192 | 0 | 2957424 | 97753 | None | Code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1461.65 | 1461.65 | 156.78 | False | None | None | False | None | False | 229157.487 | 0 | 2957425 | 97753 | None | Code13 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 130827.11 | 130827.11 | 2.15 | False | None | None | False | None | False | 281278.2865 | 0 | 2957426 | 97753 | None | Code14 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1345.14 | 1345.14 | 42.0 | False | None | None | False | None | False | 56495.88 | 0 | 2957427 | 97753 | None | Code15 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 728.18 | 728.18 | 84.0 | False | None | None | False | None | False | 61167.12 | 0 | 2957428 | 97753 | None | Code16 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 496.49 | 496.49 | 42.0 | False | None | None | False | None | False | 20852.58 | 0 | 2957429 | 97753 | None | Code17 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 198.59 | 198.59 | 62.0 | False | None | None | False | None | False | 12312.58 | 0 | 2957430 | 97753 | None | Code18 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 92.68 | 92.68 | 138.0 | False | None | None | False | None | False | 12789.84 | 0 | 2957431 | 97753 | None | Code19 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 132.4 | 132.4 | 42.0 | False | None | None | False | None | False | 5560.8 | 0 | 2957432 | 97753 | None | Code20 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1392.81 | 1392.81 | 42.0 | False | None | None | False | None | False | 58498.02 | 0 | 2957433 | 97753 | None | Code21 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 79.44 | 79.44 | 252.0 | False | None | None | False | None | False | 20018.88 | 0 | 2957434 | 97753 | None | Code22 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 68.85 | 68.85 | 261.6 | False | None | None | False | None | False | 18011.16 | 0 | 2957435 | 97753 | None | Code23 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4398.2 | 4398.2 | 144.0 | False | None | None | False | None | False | 633340.8 | 0 | 2957436 | 97753 | None | Code24 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 8915.55 | 8915.55 | 133.2 | False | None | None | False | None | False | 1187551.26 | 0 | 2957437 | 97753 | None | Code25 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7571.73 | 7571.73 | 17.52 | False | None | None | False | None | False | 132656.7096 | 0 | 2957438 | 97753 | None | Code26 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 222.43 | 222.43 | 3165.12 | False | None | None | False | None | False | 704017.6416 | 0 | 2957439 | 97753 | None | Code27 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 929.42 | 929.42 | 8.9 | False | None | None | False | None | False | 8271.838 | 0 | 2957440 | 97753 | None | Code28 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4614.0 | 4614.0 | 34.02 | False | None | None | False | None | False | 156968.28 | 0 | 2957441 | 97753 | None | Code29 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1474.89 | 1474.89 | 60.0 | False | None | None | False | None | False | 88493.4 | 0 | 2957442 | 97753 | None | Code30 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 413.08 | 413.08 | 1973.67 | False | None | None | False | None | False | 815283.6036 | 0 | 2957443 | 97753 | None | Code31 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 279.36 | 279.36 | 2676.72 | False | None | None | False | None | False | 747768.4992 | 0 | 2957444 | 97753 | None | Code32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 132.4 | 132.4 | 4650.39 | False | None | None | False | None | False | 615711.636 | 0 | 2957445 | 97753 | None | Code33 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 462.06 | 462.06 | 908.46 | False | None | None | False | None | False | 419763.0276 | 0 | 2957446 | 97753 | None | Code34 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 468.68 | 468.68 | 194.75 | False | None | None | False | None | False | 91275.43 | 0 | 2957447 | 97753 | None | Code35 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 50.31 | 50.31 | 1245.4 | False | None | None | False | None | False | 62656.074 | 0 | 2957448 | 97753 | None | Code36 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 2670.43 | 2670.43 | 15.56 | False | None | None | False | None | False | 41551.8908 | 0 | 2957449 | 97753 | None | Code37 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 814.24 | 814.24 | 82.48 | False | None | None | False | None | False | 67158.5152 | 0 | 2957450 | 97753 | None | Code38 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 283.2 | 283.2 | 50.0 | False | None | None | False | None | False | 14160.0 | 0 | 2957451 | 97753 | None | Code39 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 68.85 | 68.85 | 1118.0 | False | None | None | False | None | False | 76974.3 | 0 | 2957452 | 97753 | None | Code40 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1555.65 | 1555.65 | 1558.64 | False | None | None | False | None | False | 2424698.316 | 0 | 2957453 | 97753 | None | Code41 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1755.57 | 1755.57 | 1350.3 | False | None | None | False | None | False | 2370546.171 | 0 | 2957454 | 97753 | None | Code42 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7054.06 | 7054.06 | 188.64 | False | None | None | False | None | False | 1330677.8784 | 0 | 2957455 | 97753 | None | Code43 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 390.57 | 390.57 | 1556.22 | False | None | None | False | None | False | 607812.8454 | 0 | 2957456 | 97753 | None | Code44 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1177.0 | 1177.0 | 51.88 | False | None | None | False | None | False | 61062.76 | 0 | 2957457 | 97753 | None | Code45 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1918.42 | 1918.42 | 205.92 | False | None | None | False | None | False | 395041.0464 | 0 | 2957458 | 97753 | None | Code46 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 748.04 | 748.04 | 452.76 | False | None | None | False | None | False | 338682.5904 | 0 | 2957459 | 97753 | None | Code47 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 168.14 | 168.14 | 4650.39 | False | None | None | False | None | False | 781916.5746 | 0 | 2957460 | 97753 | None | Code48 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 206.54 | 206.54 | 908.46 | False | None | None | False | None | False | 187633.3284 | 0 | 2957461 | 97753 | None | Code49 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 66.2 | 66.2 | 150.72 | False | None | None | False | None | False | 9977.664 | 0 | 2957462 | 97753 | None | Code50 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 152.26 | 152.26 | 150.72 | False | None | None | False | None | False | 22948.6272 | 0 | 2957463 | 97753 | None | Code51 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 70.17 | 70.17 | 345.6 | False | None | None | False | None | False | 24250.752 | 0 | 2957464 | 97753 | None | Code52 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 896.32 | 896.32 | 345.6 | False | None | None | False | None | False | 309768.192 | 0 | 2957465 | 97753 | None | Code53 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 360.12 | 360.12 | 849.03 | False | None | None | False | None | False | 305752.6836 | 0 | 2957466 | 97753 | None | Code54 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4028.81 | 4028.81 | 130.62 | False | None | None | False | None | False | 526243.1622 | 0 | 2957467 | 97753 | None | Code55 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5505.03 | 5505.03 | 37.32 | False | None | None | False | None | False | 205447.7196 | 0 | 2957468 | 97753 | None | Code56 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1686.73 | 1686.73 | 145.79 | False | None | None | False | None | False | 245908.3667 | 0 | 2957469 | 97753 | None | Code57 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2241.46 | 2241.46 | 218.69 | False | None | None | False | None | False | 490184.8874 | 0 | 2957470 | 97753 | None | Code58 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5303.78 | 5303.78 | 60.0 | False | None | None | False | None | False | 318226.8 | 0 | 2957471 | 97753 | None | Code59 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 |
| 1709805442000 | 0 | None | None | Buildings | Civil Third Floor | 27235706.49 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957472 | 97754 | None | Code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - COLUMNS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15552.76 | 15552.76 | 65.34 | False | None | None | False | None | False | 1016217.3384 | 0 | 2957473 | 97754 | None | Code02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LIFT CORE WALL ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15552.76 | 15552.76 | 28.68 | False | None | None | False | None | False | 446053.1568 | 0 | 2957474 | 97754 | None | Code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC BEAMS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14637.89 | 14637.89 | 124.34 | False | None | None | False | None | False | 1820075.2426 | 0 | 2957475 | 97754 | None | Code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - RCC SLAB ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13723.02 | 13723.02 | 151.56 | False | None | None | False | None | False | 2079860.9112 | 0 | 2957476 | 97754 | None | Code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - Staircase 2 3 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13723.02 | 13723.02 | 17.05 | False | None | None | False | None | False | 233977.491 | 0 | 2957477 | 97754 | None | Code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - LINTELS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14637.89 | 14637.89 | 4.9 | False | None | None | False | None | False | 71725.661 | 0 | 2957478 | 97754 | None | Code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12852.67 | 12852.67 | 3.91 | False | None | None | False | None | False | 50253.9397 | 0 | 2957479 | 97754 | None | Code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - THIRD FLOOR, C2 600 x 600, C3 600 x 600 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 9750.3 | 9750.3 | 7.13 | False | None | None | False | None | False | 69519.639 | 0 | 2957480 | 97754 | None | Code09 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 119598.64 | 119598.64 | 56.12 | False | None | None | False | None | False | 6711875.6768 | 0 | 2957481 | 97754 | None | Code10 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 38.94 | 38.94 | 94.1 | False | None | None | False | None | False | 3664.254 | 0 | 2957482 | 97754 | None | Code11 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 86.14 | 86.14 | 94.1 | False | None | None | False | None | False | 8105.774 | 0 | 2957483 | 97754 | None | Code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1751.39 | 1751.39 | 1558.13 | False | None | None | False | None | False | 2728893.3007 | 0 | 2957484 | 97754 | None | Code13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1475.98 | 1475.98 | 51.84 | False | None | None | False | None | False | 76514.8032 | 0 | 2957485 | 97754 | None | Code14 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 132109.73 | 132109.73 | 1.6 | False | None | None | False | None | False | 211375.568 | 0 | 2957486 | 97754 | None | Code15 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1358.33 | 1358.33 | 31.0 | False | None | None | False | None | False | 42108.23 | 0 | 2957487 | 97754 | None | Code16 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Handles 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 735.32 | 735.32 | 62.0 | False | None | None | False | None | False | 45589.84 | 0 | 2957488 | 97754 | None | Code17 | Providing and fixing Stainless Steel Fixtures conforming to 304
graded steel as per direction of engineer in charge.SS Aldrop 16mm dia, 300mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 501.35 | 501.35 | 31.0 | False | None | None | False | None | False | 15541.85 | 0 | 2957489 | 97754 | None | Code18 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Tower Bolts 200x10mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 200.54 | 200.54 | 48.0 | False | None | None | False | None | False | 9625.92 | 0 | 2957490 | 97754 | None | Code19 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS hinges 100 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 93.59 | 93.59 | 103.0 | False | None | None | False | None | False | 9639.77 | 0 | 2957491 | 97754 | None | Code20 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge.SS Door stopper 75mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 133.69 | 133.69 | 31.0 | False | None | None | False | None | False | 4144.39 | 0 | 2957492 | 97754 | None | Code21 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1406.46 | 1406.46 | 31.0 | False | None | None | False | None | False | 43600.26 | 0 | 2957493 | 97754 | None | Code22 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 80.22 | 80.22 | 186.0 | False | None | None | False | None | False | 14920.92 | 0 | 2957494 | 97754 | None | Code23 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 69.52 | 69.52 | 194.1 | False | None | None | False | None | False | 13493.832 | 0 | 2957495 | 97754 | None | Code24 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 35 mm thick both side Commercial ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4441.31 | 4441.31 | 108.72 | False | None | None | False | None | False | 482859.2232 | 0 | 2957496 | 97754 | None | Code25 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 9002.95 | 9002.95 | 53.52 | False | None | None | False | None | False | 481837.884 | 0 | 2957497 | 97754 | None | Code26 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7645.96 | 7645.96 | 8.16 | False | None | None | False | None | False | 62391.0336 | 0 | 2957498 | 97754 | None | Code27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 224.61 | 224.61 | 1295.28 | False | None | None | False | None | False | 290932.8408 | 0 | 2957499 | 97754 | None | Code28 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately)Size 62 x 100mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 938.53 | 938.53 | 1.98 | False | None | None | False | None | False | 1858.2894 | 0 | 2957500 | 97754 | None | Code29 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately)30 mm thickness ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4659.24 | 4659.24 | 7.56 | False | None | None | False | None | False | 35223.8544 | 0 | 2957501 | 97754 | None | Code30 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1489.35 | 1489.35 | 35.0 | False | None | None | False | None | False | 52127.25 | 0 | 2957502 | 97754 | None | Code31 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 417.13 | 417.13 | 1658.34 | False | None | None | False | None | False | 691743.3642 | 0 | 2957503 | 97754 | None | Code32 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 282.09 | 282.09 | 1640.62 | False | None | None | False | None | False | 462802.4958 | 0 | 2957504 | 97754 | None | Code33 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 133.69 | 133.69 | 3298.96 | False | None | None | False | None | False | 441037.9624 | 0 | 2957505 | 97754 | None | Code34 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 466.59 | 466.59 | 962.7 | False | None | None | False | None | False | 449186.193 | 0 | 2957506 | 97754 | None | Code35 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per direc- tions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 473.28 | 473.28 | 97.37 | False | None | None | False | None | False | 46083.2736 | 0 | 2957507 | 97754 | None | Code36 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment.Plaster mesh 150mm wide ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 50.8 | 50.8 | 925.4 | False | None | None | False | None | False | 47010.32 | 0 | 2957508 | 97754 | None | Code37 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 2696.61 | 2696.61 | 2.3 | False | None | None | False | None | False | 6202.203 | 0 | 2957509 | 97754 | None | Code38 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel re-inforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 822.22 | 822.22 | 12.48 | False | None | None | False | None | False | 10261.3056 | 0 | 2957510 | 97754 | None | Code39 | Bore Packing : Filling the bore wherever necessary with polymer modified concrete and brushing one coat of acrylic copolymer cross linked formulaion on the bore. Including all labour charges tools and equipments, all complete as per the manufacturer. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 283.2 | 283.2 | 30.0 | False | None | None | False | None | False | 8496.0 | 0 | 2957511 | 97754 | None | Code40 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 69.52 | 69.52 | 654.33 | False | None | None | False | None | False | 45489.0216 | 0 | 2957512 | 97754 | None | Code41 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1570.9 | 1570.9 | 863.83 | False | None | None | False | None | False | 1356990.547 | 0 | 2957513 | 97754 | None | Code42 | Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1772.78 | 1772.78 | 1011.83 | False | None | None | False | None | False | 1793751.9874 | 0 | 2957514 | 97754 | None | Code43 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints fin- ished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7123.22 | 7123.22 | 188.64 | False | None | None | False | None | False | 1343724.2208 | 0 | 2957515 | 97754 | None | Code44 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 394.4 | 394.4 | 1041.59 | False | None | None | False | None | False | 410803.096 | 0 | 2957516 | 97754 | None | Code45 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick- ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1188.54 | 1188.54 | 7.68 | False | None | None | False | None | False | 9127.9872 | 0 | 2957517 | 97754 | None | Code46 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1937.23 | 1937.23 | 29.76 | False | None | None | False | None | False | 57651.9648 | 0 | 2957518 | 97754 | None | Code47 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 755.37 | 755.37 | 226.38 | False | None | None | False | None | False | 171000.6606 | 0 | 2957519 | 97754 | None | Code48 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 169.79 | 169.79 | 3298.96 | False | None | None | False | None | False | 560130.4184 | 0 | 2957520 | 97754 | None | Code49 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 208.56 | 208.56 | 962.7 | False | None | None | False | None | False | 200780.712 | 0 | 2957521 | 97754 | None | Code50 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 66.85 | 66.85 | 61.68 | False | None | None | False | None | False | 4123.308 | 0 | 2957522 | 97754 | None | Code51 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 153.75 | 153.75 | 61.68 | False | None | None | False | None | False | 9483.3 | 0 | 2957523 | 97754 | None | Code52 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 70.86 | 70.86 | 260.93 | False | None | None | False | None | False | 18489.4998 | 0 | 2957524 | 97754 | None | Code53 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 no.
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 905.11 | 905.11 | 260.93 | False | None | None | False | None | False | 236170.3523 | 0 | 2957525 | 97754 | None | Code54 | Providing and supplying aluminium extruded tubular and other alu- minium sections as per the architectural drawings and approved draw- ings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 363.65 | 363.65 | 221.13 | False | None | None | False | None | False | 80413.9245 | 0 | 2957526 | 97754 | None | Code55 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/ m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 4068.31 | 4068.31 | 34.02 | False | None | None | False | None | False | 138403.9062 | 0 | 2957527 | 97754 | None | Code56 | Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5559.0 | 5559.0 | 9.72 | False | None | None | False | None | False | 54033.48 | 0 | 2957528 | 97754 | None | Code57 | Providing and fixing in position 12mm thick plaster of paris (Gypsum anhydrous) for ceiling reinforced with hessian cloth flat surface with ceiling tiles up to a height of 5 m above floor level over aluminium strips 25mm x 6mm and rendered smooth with plaster of paris including cost of materials, labour, curing complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1703.26 | 1703.26 | 144.66 | False | None | None | False | None | False | 246393.5916 | 0 | 2957529 | 97754 | None | Code58 | Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per m2 including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2263.44 | 2263.44 | 217.0 | False | None | None | False | None | False | 491166.48 | 0 | 2957530 | 97754 | None | Code59 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca- tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5355.78 | 5355.78 | 60.0 | False | None | None | False | None | False | 321346.8 | 0 | 2957531 | 97754 | None | Code60 | Providing and fixing aluminium coated and polyester based netted curtains complete. The work includes cost of all materials, labour charges, lead and lift, etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2596.0 | 2596.0 | 150.0 | False | None | None | False | None | False | 389400.0 | 0 |
| 1709805442000 | 0 | None | None | Buildings | Civil Terrace floor | 7133869.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957532 | 97755 | None | Code01 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - COLUMNS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15703.75 | 15703.75 | 5.76 | False | None | None | False | None | False | 90453.6 | 0 | 2957533 | 97755 | None | Code02 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork -RCC BEAMS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14780.0 | 14780.0 | 11.52 | False | None | None | False | None | False | 170265.6 | 0 | 2957534 | 97755 | None | Code03 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork -RCC SLAB ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13856.25 | 13856.25 | 12.2 | False | None | None | False | None | False | 169046.25 | 0 | 2957535 | 97755 | None | Code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork -LINTELS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14780.0 | 14780.0 | 0.62 | False | None | None | False | None | False | 9163.6 | 0 | 2957536 | 97755 | None | Code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12977.46 | 12977.46 | 0.89 | False | None | None | False | None | False | 11549.9394 | 0 | 2957537 | 97755 | None | Code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - TERRACE FLOOR C4 600x600, C5 600x600 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12977.46 | 12977.46 | 13.39 | False | None | None | False | None | False | 173768.1894 | 0 | 2957538 | 97755 | None | Code07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 120759.79 | 120759.79 | 6.41 | False | None | None | False | None | False | 774070.2539 | 0 | 2957539 | 97755 | None | Code08 | Extra for providing throating or drip moulding to RCC chejjas with plastering ( labour charges only ) as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 38.94 | 38.94 | 23.1 | False | None | None | False | None | False | 899.514 | 0 | 2957540 | 97755 | None | Code09 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 86.14 | 86.14 | 152.0 | False | None | None | False | None | False | 13093.28 | 0 | 2957541 | 97755 | None | Code10 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1768.4 | 1768.4 | 347.16 | False | None | None | False | None | False | 613917.744 | 0 | 2957542 | 97755 | None | Code11 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 9090.36 | 9090.36 | 10.8 | False | None | None | False | None | False | 98175.888 | 0 | 2957543 | 97755 | None | Code12 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 226.79 | 226.79 | 283.5 | False | None | None | False | None | False | 64294.965 | 0 | 2957544 | 97755 | None | Code13 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 6044.94 | 6044.94 | 7.2 | False | None | None | False | None | False | 43523.568 | 0 | 2957545 | 97755 | None | Code14 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge... ( Inside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 421.18 | 421.18 | 561.78 | False | None | None | False | None | False | 236610.5004 | 0 | 2957546 | 97755 | None | Code15 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 284.83 | 284.83 | 664.8 | False | None | None | False | None | False | 189354.984 | 0 | 2957547 | 97755 | None | Code16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 134.99 | 134.99 | 1226.58 | False | None | None | False | None | False | 165576.0342 | 0 | 2957548 | 97755 | None | Code17 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.. ( Outside) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 471.12 | 471.12 | 567.98 | False | None | None | False | None | False | 267586.7376 | 0 | 2957549 | 97755 | None | Code18 | Roof Water Proofing. Surface Preparation: remove all surface laitance and contamination free from loose aggregate or other sharp protrusions with fairly smooth finish by wire brush and grinding method and surface shall be DRY for application of single component pitch modified polyurethane cures by reaction with atmospheric moisture to given a tough elastomeric waterproof membrane.
System : Provide and applying 1.2 mm thick roller applied single component bitumen modified polyurathene coating NITPROOF 600 or equivalent, having elongation capacity of 450 % as per ASTM D412, having Tensile strength 1.5 n/mm2 as per ASTM D 412, Tear resistance of 15 N as per ASTM D 624 and having shore A Hardness 50 as per ASTM D 2240. Waterproofing treatment to be provided after proper surface preparation as per Manufacture Specification.
Protection of waterproofing system with minimum 50 mm thick screed and providing construction joints and sealing the same with PU sealant.TERRACE FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1593.0 | 1593.0 | 2265.0 | False | None | None | False | None | False | 3608145.0 | 0 | 2957550 | 97755 | None | Code19 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 171.44 | 171.44 | 1226.58 | False | None | None | False | None | False | 210284.8752 | 0 | 2957551 | 97755 | None | Code20 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 210.59 | 210.59 | 567.98 | False | None | None | False | None | False | 119610.9082 | 0 | 2957552 | 97755 | None | Code21 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 67.5 | 67.5 | 20.7 | False | None | None | False | None | False | 1397.25 | 0 | 2957553 | 97755 | None | Code22 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 155.24 | 155.24 | 20.7 | False | None | None | False | None | False | 3213.468 | 0 | 2957554 | 97755 | None | Code23 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 554.82 | 554.82 | 180.0 | False | None | None | False | None | False | 99867.6 | 0 |
| 1709805442000 | 0 | None | None | Buildings | Internal water supply & sanitary works | 7441159.59 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957555 | 97756 | None | Code01 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40mm dia pipes, From wash basin waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 394.59 | 394.59 | 85.0 | False | None | None | False | None | False | 33540.15 | 0 | 2957556 | 97756 | None | Code02 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-50mm dia pipes, From sink & urinal waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 501.03 | 501.03 | 60.0 | False | None | None | False | None | False | 30061.8 | 0 | 2957557 | 97756 | None | Code03 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Internal drainage)-75mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 375.12 | 375.12 | 465.0 | False | None | None | False | None | False | 174430.8 | 0 | 2957558 | 97756 | None | Code04 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (Internal drainage)-110mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 499.73 | 499.73 | 450.0 | False | None | None | False | None | False | 224878.5 | 0 | 2957559 | 97756 | None | Code05 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 75mm diameter ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 255.71 | 255.71 | 35.0 | False | None | None | False | None | False | 8949.85 | 0 | 2957560 | 97756 | None | Code06 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 351.76 | 351.76 | 295.0 | False | None | None | False | None | False | 103769.2 | 0 | 2957561 | 97756 | None | Code07 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1583.56 | 1583.56 | 18.0 | False | None | None | False | None | False | 28504.08 | 0 | 2957562 | 97756 | None | Code08 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 804.76 | 804.76 | 75.0 | False | None | None | False | None | False | 60357.0 | 0 | 2957563 | 97756 | None | Code09 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6279.72 | 6279.72 | 23.0 | False | None | None | False | None | False | 144433.56 | 0 | 2957564 | 97756 | None | Code10 | Providing and fixing CP brass toilet paper holder ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 738.96 | 738.96 | 23.0 | False | None | None | False | None | False | 16996.08 | 0 | 2957565 | 97756 | None | Code11 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5781.29 | 5781.29 | 6.0 | False | None | None | False | None | False | 34687.74 | 0 | 2957566 | 97756 | None | Code12 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 941.05 | 941.05 | 16.0 | False | None | None | False | None | False | 15056.8 | 0 | 2957567 | 97756 | None | Code13 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4000.44 | 4000.44 | 25.0 | False | None | None | False | None | False | 100011.0 | 0 | 2957568 | 97756 | None | Code14 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1051.38 | 1051.38 | 18.0 | False | None | None | False | None | False | 18924.84 | 0 | 2957569 | 97756 | None | Code15 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 107.73 | 107.73 | 59.0 | False | None | None | False | None | False | 6356.07 | 0 | 2957570 | 97756 | None | Code16 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 397.19 | 397.19 | 18.0 | False | None | None | False | None | False | 7149.42 | 0 | 2957571 | 97756 | None | Code17 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.-15 mm nominal bore, weighing not less than 32 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 83.07 | 83.07 | 23.0 | False | None | None | False | None | False | 1910.61 | 0 | 2957572 | 97756 | None | Code18 | Providing and fixing brass bib cock of approved quality-15 mmdia nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 371.23 | 371.23 | 15.0 | False | None | None | False | None | False | 5568.45 | 0 | 2957573 | 97756 | None | Code19 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 316.71 | 316.71 | 35.0 | False | None | None | False | None | False | 11084.85 | 0 | 2957574 | 97756 | None | Code20 | Providing and fixing PVC (S.W.R) P Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 285.56 | 285.56 | 2.0 | False | None | None | False | None | False | 571.12 | 0 | 2957575 | 97756 | None | Code21 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7219.48 | 7219.48 | 8.0 | False | None | None | False | None | False | 57755.84 | 0 | 2957576 | 97756 | None | Code22 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 362.14 | 362.14 | 8.0 | False | None | None | False | None | False | 2897.12 | 0 | 2957577 | 97756 | None | Code23 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 643.81 | 643.81 | 8.0 | False | None | None | False | None | False | 5150.48 | 0 | 2957578 | 97756 | None | Code24 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 711.3 | 711.3 | 23.0 | False | None | None | False | None | False | 16359.9 | 0 | 2957579 | 97756 | None | Code25 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2266.31 | 2266.31 | 4.0 | False | None | None | False | None | False | 9065.24 | 0 | 2957580 | 97756 | None | Code26 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 419.25 | 419.25 | 12.0 | False | None | None | False | None | False | 5031.0 | 0 | 2957581 | 97756 | None | Code27 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 406.27 | 406.27 | 12.0 | False | None | None | False | None | False | 4875.24 | 0 | 2957582 | 97756 | None | Code28 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6271.94 | 6271.94 | 1.0 | False | None | None | False | None | False | 6271.94 | 0 | 2957583 | 97756 | None | Code29 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-15 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 401.08 | 401.08 | 45.0 | False | None | None | False | None | False | 18048.6 | 0 | 2957584 | 97756 | None | Code30 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-20 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 491.94 | 491.94 | 275.0 | False | None | None | False | None | False | 135283.5 | 0 | 2957585 | 97756 | None | Code31 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-25 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 619.15 | 619.15 | 160.0 | False | None | None | False | None | False | 99064.0 | 0 | 2957586 | 97756 | None | Code32 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-32 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 722.99 | 722.99 | 130.0 | False | None | None | False | None | False | 93988.7 | 0 | 2957587 | 97756 | None | Code33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -25mm DWS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 412.76 | 412.76 | 165.0 | False | None | None | False | None | False | 68105.4 | 0 | 2957588 | 97756 | None | Code34 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -32mm DWS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 519.2 | 519.2 | 185.0 | False | None | None | False | None | False | 96052.0 | 0 | 2957589 | 97756 | None | Code35 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -40 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 695.73 | 695.73 | 165.0 | False | None | None | False | None | False | 114795.45 | 0 | 2957590 | 97756 | None | Code36 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -50 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1013.74 | 1013.74 | 145.0 | False | None | None | False | None | False | 146992.3 | 0 | 2957591 | 97756 | None | Code37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-32 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 482.86 | 482.86 | 65.0 | False | None | None | False | None | False | 31385.9 | 0 | 2957592 | 97756 | None | Code38 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 619.15 | 619.15 | 375.0 | False | None | None | False | None | False | 232181.25 | 0 | 2957593 | 97756 | None | Code39 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-50 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 935.86 | 935.86 | 225.0 | False | None | None | False | None | False | 210568.5 | 0 | 2957594 | 97756 | None | Code40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-65 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1817.2 | 1817.2 | 200.0 | False | None | None | False | None | False | 363440.0 | 0 | 2957595 | 97756 | None | Code41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-80 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 2327.31 | 2327.31 | 250.0 | False | None | None | False | None | False | 581827.5 | 0 | 2957596 | 97756 | None | Code42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-100 mm dia nomina; dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 3276.15 | 3276.15 | 25.0 | False | None | None | False | None | False | 81903.75 | 0 | 2957597 | 97756 | None | Code43 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :-25 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 883.94 | 883.94 | 30.0 | False | None | None | False | None | False | 26518.2 | 0 | 2957598 | 97756 | None | Code44 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-25 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 712.6 | 712.6 | 20.0 | False | None | None | False | None | False | 14252.0 | 0 | 2957599 | 97756 | None | Code45 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-32 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 771.01 | 771.01 | 15.0 | False | None | None | False | None | False | 11565.15 | 0 | 2957600 | 97756 | None | Code46 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-40 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 911.2 | 911.2 | 15.0 | False | None | None | False | None | False | 13668.0 | 0 | 2957601 | 97756 | None | Code47 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-50 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1109.79 | 1109.79 | 15.0 | False | None | None | False | None | False | 16646.85 | 0 | 2957602 | 97756 | None | Code48 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-65 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1831.48 | 1831.48 | 10.0 | False | None | None | False | None | False | 18314.8 | 0 | 2957603 | 97756 | None | Code49 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-80 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2695.95 | 2695.95 | 6.0 | False | None | None | False | None | False | 16175.7 | 0 | 2957604 | 97756 | None | Code50 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-150mm dia CI butterfly valves ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 16225.0 | 16225.0 | 4.0 | False | None | None | False | None | False | 64900.0 | 0 | 2957605 | 97756 | None | Code51 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-100mm dia CI butterfly valves ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11682.0 | 11682.0 | 6.0 | False | None | None | False | None | False | 70092.0 | 0 | 2957606 | 97756 | None | Code52 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etccomplete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for uccessful completion of work and as per directions of the Engineer-in-charge of the work-100 mm Dia CI Non Return Valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9241.76 | 9241.76 | 2.0 | False | None | None | False | None | False | 18483.52 | 0 | 2957607 | 97756 | None | Code53 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etccomplete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for uccessful completion of work and as per directions of the Engineer-in-charge of the work-80 mm Dia CI Non Return Valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7139.0 | 7139.0 | 4.0 | False | None | None | False | None | False | 28556.0 | 0 | 2957608 | 97756 | None | Code54 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etccomplete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for uccessful completion of work and as per directions of the Engineer-in-charge of the work-65 mm Dia CI Non Return Valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5646.3 | 5646.3 | 6.0 | False | None | None | False | None | False | 33877.8 | 0 | 2957609 | 97756 | None | Code55 | Supplying installing, testing and commissioning of PN 16 CI Non Return Valve confirming to IS 13039 with necessary bolts and nuts etc complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etccomplete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for uccessful completion of work and as per directions of the Engineer-in-charge of the work-50 mm Dia CI Non Return Valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3840.78 | 3840.78 | 6.0 | False | None | None | False | None | False | 23044.68 | 0 | 2957610 | 97756 | None | Code56 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40mm dia pipes, From wash basin waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 398.54 | 398.54 | 95.0 | False | None | None | False | None | False | 37861.3 | 0 | 2957611 | 97756 | None | Code57 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittingsThis includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-50mm dia pipes, From sink & urinal waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 506.04 | 506.04 | 65.0 | False | None | None | False | None | False | 32892.6 | 0 | 2957612 | 97756 | None | Code58 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-75mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 378.87 | 378.87 | 350.0 | False | None | None | False | None | False | 132604.5 | 0 | 2957613 | 97756 | None | Code59 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-110mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 504.73 | 504.73 | 325.0 | False | None | None | False | None | False | 164037.25 | 0 | 2957614 | 97756 | None | Code60 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1599.4 | 1599.4 | 18.0 | False | None | None | False | None | False | 28789.2 | 0 | 2957615 | 97756 | None | Code61 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 812.81 | 812.81 | 96.0 | False | None | None | False | None | False | 78029.76 | 0 | 2957616 | 97756 | None | Code62 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6342.52 | 6342.52 | 28.0 | False | None | None | False | None | False | 177590.56 | 0 | 2957617 | 97756 | None | Code63 | Providing and fixing CP brass toilet paper holder ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 797.08 | 797.08 | 28.0 | False | None | None | False | None | False | 22318.24 | 0 | 2957618 | 97756 | None | Code64 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5839.1 | 5839.1 | 6.0 | False | None | None | False | None | False | 35034.6 | 0 | 2957619 | 97756 | None | Code65 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 950.46 | 950.46 | 24.0 | False | None | None | False | None | False | 22811.04 | 0 | 2957620 | 97756 | None | Code66 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4040.44 | 4040.44 | 22.0 | False | None | None | False | None | False | 88889.68 | 0 | 2957621 | 97756 | None | Code67 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1061.89 | 1061.89 | 22.0 | False | None | None | False | None | False | 23361.58 | 0 | 2957622 | 97756 | None | Code68 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 108.81 | 108.81 | 45.0 | False | None | None | False | None | False | 4896.45 | 0 | 2957623 | 97756 | None | Code69 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 401.16 | 401.16 | 22.0 | False | None | None | False | None | False | 8825.52 | 0 | 2957624 | 97756 | None | Code70 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.-15 mm nominal bore, weighing not less than 32 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 83.9 | 83.9 | 28.0 | False | None | None | False | None | False | 2349.2 | 0 | 2957625 | 97756 | None | Code71 | Providing and fixing brass bib cock of approved quality-15 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 374.94 | 374.94 | 16.0 | False | None | None | False | None | False | 5999.04 | 0 | 2957626 | 97756 | None | Code72 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 319.88 | 319.88 | 45.0 | False | None | None | False | None | False | 14394.6 | 0 | 2957627 | 97756 | None | Code73 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7291.67 | 7291.67 | 12.0 | False | None | None | False | None | False | 87500.04 | 0 | 2957628 | 97756 | None | Code74 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 365.76 | 365.76 | 12.0 | False | None | None | False | None | False | 4389.12 | 0 | 2957629 | 97756 | None | Code75 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 650.25 | 650.25 | 12.0 | False | None | None | False | None | False | 7803.0 | 0 | 2957630 | 97756 | None | Code76 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 718.42 | 718.42 | 28.0 | False | None | None | False | None | False | 20115.76 | 0 | 2957631 | 97756 | None | Code77 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2288.97 | 2288.97 | 4.0 | False | None | None | False | None | False | 9155.88 | 0 | 2957632 | 97756 | None | Code78 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 423.45 | 423.45 | 15.0 | False | None | None | False | None | False | 6351.75 | 0 | 2957633 | 97756 | None | Code79 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 410.34 | 410.34 | 15.0 | False | None | None | False | None | False | 6155.1 | 0 | 2957634 | 97756 | None | Code80 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6334.66 | 6334.66 | 1.0 | False | None | None | False | None | False | 6334.66 | 0 | 2957635 | 97756 | None | Code81 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-15 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 405.09 | 405.09 | 50.0 | False | None | None | False | None | False | 20254.5 | 0 | 2957636 | 97756 | None | Code82 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-20 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 496.86 | 496.86 | 235.0 | False | None | None | False | None | False | 116762.1 | 0 | 2957637 | 97756 | None | Code83 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-25 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 625.34 | 625.34 | 145.0 | False | None | None | False | None | False | 90674.3 | 0 | 2957638 | 97756 | None | Code84 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-32 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 730.22 | 730.22 | 135.0 | False | None | None | False | None | False | 98579.7 | 0 | 2957639 | 97756 | None | Code85 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -25mm DWS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 416.89 | 416.89 | 105.0 | False | None | None | False | None | False | 43773.45 | 0 | 2957640 | 97756 | None | Code86 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 524.39 | 524.39 | 85.0 | False | None | None | False | None | False | 44573.15 | 0 | 2957641 | 97756 | None | Code87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -40 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 702.69 | 702.69 | 50.0 | False | None | None | False | None | False | 35134.5 | 0 | 2957642 | 97756 | None | Code88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -50 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1023.88 | 1023.88 | 60.0 | False | None | None | False | None | False | 61432.8 | 0 | 2957643 | 97756 | None | Code89 | Providing and fixing ball valve (brass) of approved quality, High or low
pressure, with plastic floats complete : ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 435.25 | 435.25 | 2.0 | False | None | None | False | None | False | 870.5 | 0 | 2957644 | 97756 | None | Code90 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40mm dia pipes, From wash basin waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 402.48 | 402.48 | 65.0 | False | None | None | False | None | False | 26161.2 | 0 | 2957645 | 97756 | None | Code91 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solventcement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-50mm dia pipes, From sink & urinal waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 511.05 | 511.05 | 45.0 | False | None | None | False | None | False | 22997.25 | 0 | 2957646 | 97756 | None | Code92 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-75mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 382.62 | 382.62 | 185.0 | False | None | None | False | None | False | 70784.7 | 0 | 2957647 | 97756 | None | Code93 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-110mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 509.72 | 509.72 | 165.0 | False | None | None | False | None | False | 84103.8 | 0 | 2957648 | 97756 | None | Code94 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1615.23 | 1615.23 | 8.0 | False | None | None | False | None | False | 12921.84 | 0 | 2957649 | 97756 | None | Code95 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 820.86 | 820.86 | 30.0 | False | None | None | False | None | False | 24625.8 | 0 | 2957650 | 97756 | None | Code96 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6405.32 | 6405.32 | 10.0 | False | None | None | False | None | False | 64053.2 | 0 | 2957651 | 97756 | None | Code97 | Providing and fixing CP brass toilet paper holder ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 804.97 | 804.97 | 10.0 | False | None | None | False | None | False | 8049.7 | 0 | 2957652 | 97756 | None | Code98 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5896.92 | 5896.92 | 4.0 | False | None | None | False | None | False | 23587.68 | 0 | 2957653 | 97756 | None | Code99 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 959.87 | 959.87 | 4.0 | False | None | None | False | None | False | 3839.48 | 0 | 2957654 | 97756 | None | Code100 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4080.44 | 4080.44 | 8.0 | False | None | None | False | None | False | 32643.52 | 0 | 2957655 | 97756 | None | Code101 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1072.41 | 1072.41 | 8.0 | False | None | None | False | None | False | 8579.28 | 0 | 2957656 | 97756 | None | Code102 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 109.89 | 109.89 | 26.0 | False | None | None | False | None | False | 2857.14 | 0 | 2957657 | 97756 | None | Code103 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 405.13 | 405.13 | 8.0 | False | None | None | False | None | False | 3241.04 | 0 | 2957658 | 97756 | None | Code104 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.-15 mm nominal bore, weighing not less than 32 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 84.73 | 84.73 | 10.0 | False | None | None | False | None | False | 847.3 | 0 | 2957659 | 97756 | None | Code105 | Providing and fixing brass bib cock of approved quality - 15 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 378.65 | 378.65 | 10.0 | False | None | None | False | None | False | 3786.5 | 0 | 2957660 | 97756 | None | Code106 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 323.05 | 323.05 | 20.0 | False | None | None | False | None | False | 6461.0 | 0 | 2957661 | 97756 | None | Code107 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7363.87 | 7363.87 | 2.0 | False | None | None | False | None | False | 14727.74 | 0 | 2957662 | 97756 | None | Code108 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 369.38 | 369.38 | 2.0 | False | None | None | False | None | False | 738.76 | 0 | 2957663 | 97756 | None | Code109 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 656.68 | 656.68 | 2.0 | False | None | None | False | None | False | 1313.36 | 0 | 2957664 | 97756 | None | Code110 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 725.53 | 725.53 | 10.0 | False | None | None | False | None | False | 7255.3 | 0 | 2957665 | 97756 | None | Code111 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2311.63 | 2311.63 | 2.0 | False | None | None | False | None | False | 4623.26 | 0 | 2957666 | 97756 | None | Code112 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 427.64 | 427.64 | 10.0 | False | None | None | False | None | False | 4276.4 | 0 | 2957667 | 97756 | None | Code113 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 414.4 | 414.4 | 10.0 | False | None | None | False | None | False | 4144.0 | 0 | 2957668 | 97756 | None | Code114 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6397.37 | 6397.37 | 1.0 | False | None | None | False | None | False | 6397.37 | 0 | 2957669 | 97756 | None | Code115 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-15 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 409.1 | 409.1 | 75.0 | False | None | None | False | None | False | 30682.5 | 0 | 2957670 | 97756 | None | Code116 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-20 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 501.78 | 501.78 | 50.0 | False | None | None | False | None | False | 25089.0 | 0 | 2957671 | 97756 | None | Code117 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-25 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 631.53 | 631.53 | 100.0 | False | None | None | False | None | False | 63153.0 | 0 | 2957672 | 97756 | None | Code118 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-32 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 737.45 | 737.45 | 50.0 | False | None | None | False | None | False | 36872.5 | 0 | 2957673 | 97756 | None | Code119 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall - 25mm pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 421.02 | 421.02 | 105.0 | False | None | None | False | None | False | 44207.1 | 0 | 2957674 | 97756 | None | Code120 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -32mm pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 529.58 | 529.58 | 85.0 | False | None | None | False | None | False | 45014.3 | 0 | 2957675 | 97756 | None | Code121 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -40 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 709.64 | 709.64 | 50.0 | False | None | None | False | None | False | 35482.0 | 0 | 2957676 | 97756 | None | Code122 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -50 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1034.01 | 1034.01 | 60.0 | False | None | None | False | None | False | 62040.6 | 0 | 2957677 | 97756 | None | Code123 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work-40mm dia pipes, From wash basin waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 406.43 | 406.43 | 15.0 | False | None | None | False | None | False | 6096.45 | 0 | 2957678 | 97756 | None | Code124 | Providing and fixing Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step uPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work- 50mm dia pipes, From sink & urinal waste lines ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 516.06 | 516.06 | 15.0 | False | None | None | False | None | False | 7740.9 | 0 | 2957679 | 97756 | None | Code125 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-75mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 386.38 | 386.38 | 65.0 | False | None | None | False | None | False | 25114.7 | 0 | 2957680 | 97756 | None | Code126 | Providing and fixing Sewer (SWR) pipes, including all fittings, This includes jointing of pipes & fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. ( Internal drainage)-110mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 514.72 | 514.72 | 65.0 | False | None | None | False | None | False | 33456.8 | 0 | 2957681 | 97756 | None | Code127 | Providing and fixing 600x450 mm beveled edge mirror of superior glass(of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1631.07 | 1631.07 | 2.0 | False | None | None | False | None | False | 3262.14 | 0 | 2957682 | 97756 | None | Code128 | Providing and fixing C.P. brass angle valve for basin mixer and geyser
points of approved quality conforming to IS:8931 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 828.9 | 828.9 | 2.0 | False | None | None | False | None | False | 1657.8 | 0 | 2957683 | 97756 | None | Code129 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6468.12 | 6468.12 | 2.0 | False | None | None | False | None | False | 12936.24 | 0 | 2957684 | 97756 | None | Code130 | Providing and fixing CP brass toilet paper holder ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 812.86 | 812.86 | 2.0 | False | None | None | False | None | False | 1625.72 | 0 | 2957685 | 97756 | None | Code131 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: One urinal basin with 5 litre white P.V.C. automatic flushing cistern ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5954.73 | 5954.73 | 2.0 | False | None | None | False | None | False | 11909.46 | 0 | 2957686 | 97756 | None | Code132 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 969.28 | 969.28 | 4.0 | False | None | None | False | None | False | 3877.12 | 0 | 2957687 | 97756 | None | Code133 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15mm C.P. brass pillar taps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4120.45 | 4120.45 | 2.0 | False | None | None | False | None | False | 8240.9 | 0 | 2957688 | 97756 | None | Code134 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality& make and as per the direction of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1082.92 | 1082.92 | 8.0 | False | None | None | False | None | False | 8663.36 | 0 | 2957689 | 97756 | None | Code135 | Providing and fixing unplasticised PVC connection pipe with brass unions :(30 cm length 15 mm nominal bore) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 110.97 | 110.97 | 8.0 | False | None | None | False | None | False | 887.76 | 0 | 2957690 | 97756 | None | Code136 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 409.1 | 409.1 | 2.0 | False | None | None | False | None | False | 818.2 | 0 | 2957691 | 97756 | None | Code137 | Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour.-15 mm nominal bore, weighing not less than 32 g ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 85.56 | 85.56 | 2.0 | False | None | None | False | None | False | 171.12 | 0 | 2957692 | 97756 | None | Code138 | Providing and fixing brass bib cock of approved quality-15 mm nominal bore ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 382.36 | 382.36 | 4.0 | False | None | None | False | None | False | 1529.44 | 0 | 2957693 | 97756 | None | Code139 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm x 7.5 cm x 5.0 cm x4.0 cm with all fitting arrangements & all necessary accessories complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 326.21 | 326.21 | 15.0 | False | None | None | False | None | False | 4893.15 | 0 | 2957694 | 97756 | None | Code140 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7436.06 | 7436.06 | 1.0 | False | None | None | False | None | False | 7436.06 | 0 | 2957695 | 97756 | None | Code141 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 373.01 | 373.01 | 1.0 | False | None | None | False | None | False | 373.01 | 0 | 2957696 | 97756 | None | Code142 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 663.12 | 663.12 | 1.0 | False | None | None | False | None | False | 663.12 | 0 | 2957697 | 97756 | None | Code143 | Providing and fixing Robe hook twin made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 732.64 | 732.64 | 2.0 | False | None | None | False | None | False | 1465.28 | 0 | 2957698 | 97756 | None | Code144 | Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class Economy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2334.3 | 2334.3 | 1.0 | False | None | None | False | None | False | 2334.3 | 0 | 2957699 | 97756 | None | Code145 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. (non modular) bricks ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 431.83 | 431.83 | 2.0 | False | None | None | False | None | False | 863.66 | 0 | 2957700 | 97756 | None | Code146 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size), including finishing complete so as to
make it leak proof. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 418.46 | 418.46 | 2.0 | False | None | None | False | None | False | 836.92 | 0 | 2957701 | 97756 | None | Code147 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board-510x1040 mm bowl depth 178 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6460.09 | 6460.09 | 1.0 | False | None | None | False | None | False | 6460.09 | 0 | 2957702 | 97756 | None | Code148 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-15 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 413.11 | 413.11 | 25.0 | False | None | None | False | None | False | 10327.75 | 0 | 2957703 | 97756 | None | Code149 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-20 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 506.7 | 506.7 | 125.0 | False | None | None | False | None | False | 63337.5 | 0 | 2957704 | 97756 | None | Code150 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-25 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 637.72 | 637.72 | 85.0 | False | None | None | False | None | False | 54206.2 | 0 | 2957705 | 97756 | None | Code151 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.-32 mm nominal dia pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 744.68 | 744.68 | 25.0 | False | None | None | False | None | False | 18617.0 | 0 | 2957706 | 97756 | None | Code152 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -25mm DWS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 425.15 | 425.15 | 35.0 | False | None | None | False | None | False | 14880.25 | 0 | 2957707 | 97756 | None | Code153 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -32mm DWS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 534.78 | 534.78 | 25.0 | False | None | None | False | None | False | 13369.5 | 0 | 2957708 | 97756 | None | Code154 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -40 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 716.6 | 716.6 | 20.0 | False | None | None | False | None | False | 14332.0 | 0 | 2957709 | 97756 | None | Code155 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall -50 mm nominal dia Pipes ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1044.15 | 1044.15 | 15.0 | False | None | None | False | None | False | 15662.25 | 0 | 2957710 | 97756 | None | Code156 | Providing, fixing, testing and commissioning of Air Vent Cowel 110mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 219.48 | 219.48 | 8.0 | False | None | None | False | None | False | 1755.84 | 0 | 2957711 | 97756 | None | Code157 | Providing, fixing, testing and commissioning of Air Vent Cowel 75mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 189.98 | 189.98 | 11.0 | False | None | None | False | None | False | 2089.78 | 0 | 2957712 | 97756 | None | Code158 | Supplying and fixing Counter basin consisting of size: 420 x 590 x 195, Shape: oval of ISI or BIS Standards with a single 15mm C.P. 32mm dia CP waste coupling, 32mmdia heavy duty CP bottle trap. CP pillar cock with extension pipe, CP wall flanges, 1 Nos.15mm dia C.P. angle cocks, 2nos.C.P. flexible inlet connection pipes, CI brackets etc., complete including silicon sealant filling. (Jaguar make or Equalent ) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9318.46 | 9318.46 | 28.0 | False | None | None | False | None | False | 260916.88 | 0 | 2957713 | 97756 | None | Code159 | Supplying, fixing, testing and commissioning of CP health faucet Hand operated spray unit (instant type) CP Crutch etc., complete as directed by the Engineer in charge. ALD-577. (Jaguar make or Equalent) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2558.24 | 2558.24 | 59.0 | False | None | None | False | None | False | 150936.16 | 0 | 2957714 | 97756 | None | Code160 | Construction of stormwater Recharge pit of size 1.2m dia clear x 5.0m depth using precast concrete rungs with perforations at regular intervals. Bottom 600mm depth of pit shall be filled with coarse sand and the balance up to the invert of the Recharge pit inlet shall be filled with brick bats of 40mm and below size. The top of the Recharge pit shall be covered with RCC slab of suitable thickness with RCC 1:2:4 with 600 x 600mm RCC manhole frame cover. PCC bed of 1:3:6 100mm thick shall be provided for the Recharge pit walls. Earthwork excavation for Recharge pit in all types of soil and backfilling with suitable earth, including interconnecting RCC hume pipes from storm water drain to recharge pit. etc., complete. The scope of work included with drilling 160mm dia bore ho;e upto a depth of 20m. borewell providing perforated pipe and geotextile wrapping etc, complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 53100.0 | 53100.0 | 6.0 | False | None | None | False | None | False | 318600.0 | 0 | 2957715 | 97756 | None | Code161 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. (In shaft amd terrace)-20 mmdia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 206.5 | 206.5 | 350.0 | False | None | None | False | None | False | 72275.0 | 0 | 2957716 | 97756 | None | Code162 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. (In shaft amd terrace)-25 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 236.0 | 236.0 | 185.0 | False | None | None | False | None | False | 43660.0 | 0 | 2957717 | 97756 | None | Code163 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. (In shaft amd terrace)-32 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 265.5 | 265.5 | 135.0 | False | None | None | False | None | False | 35842.5 | 0 | 2957718 | 97756 | None | Code164 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. (In shaft amd terrace)-40 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 295.0 | 295.0 | 120.0 | False | None | None | False | None | False | 35400.0 | 0 | 2957719 | 97756 | None | Code165 | Providing & fixing of insulation for exposed hot water CPVC hot water pipes with VIDOFLEX 9 mm preformed tubings wrapped all round. All joints shall be sealed with POLYBOND V (adhesive, followed by application of self adhesive, black cotton tape PCS 2250, on both longitudinal & circumferenacial joints to give uniform apperance and finish, including cladding with heavy gauge aluminium sheet and rivetting the same. (In shaft amd terrace)-50 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 354.0 | 354.0 | 25.0 | False | None | None | False | None | False | 8850.0 | 0 | 2957720 | 97756 | None | Code166 | Supply and instalation of GI Class C puddle flanges-32 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 944.0 | 944.0 | 6.0 | False | None | None | False | None | False | 5664.0 | 0 | 2957721 | 97756 | None | Code167 | Supply and instalation of GI Class C puddle flanges-40mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1770.0 | 1770.0 | 6.0 | False | None | None | False | None | False | 10620.0 | 0 | 2957722 | 97756 | None | Code168 | Supply and instalation of GI Class C puddle flanges-50mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2360.0 | 2360.0 | 12.0 | False | None | None | False | None | False | 28320.0 | 0 | 2957723 | 97756 | None | Code169 | Supply and instalation of GI Class C puddle flanges-65 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2950.0 | 2950.0 | 6.0 | False | None | None | False | None | False | 17700.0 | 0 |
| 1709805442000 | 0 | None | None | Buildings | Internal Electrification | 31266241.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957724 | 97757 | None | Code01 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Short point up to 3mtr from tapping point to out let via switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Point | 349.16 | 349.16 | 275.0 | False | None | None | False | None | False | 96019.0 | 0 | 2957725 | 97757 | None | Code02 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Medium point above 3mtr up to 6mtr from tapping point to out let via switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Point | 491.94 | 491.94 | 325.0 | False | None | None | False | None | False | 159880.5 | 0 | 2957726 | 97757 | None | Code03 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Long point above 6mtr up to 10mtr from tapping point to out let via switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Point | 720.39 | 720.39 | 375.0 | False | None | None | False | None | False | 270146.25 | 0 | 2957727 | 97757 | None | Code04 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Two outlet in a row, above 3mtr up to 6mtr from tapping point to out let via switches ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Point | 878.75 | 878.75 | 52.0 | False | None | None | False | None | False | 45695.0 | 0 | 2957728 | 97757 | None | Code05 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each
outlet. Three outlet in a row, above 6Mts up to 10mtr from tapping point to out let via switches ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Point | 1283.72 | 1283.72 | 35.0 | False | None | None | False | None | False | 44930.2 | 0 | 2957729 | 97757 | None | Code06 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2Way ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 179.12 | 179.12 | 387.0 | False | None | None | False | None | False | 69319.44 | 0 | 2957730 | 97757 | None | Code07 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3Way ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 206.38 | 206.38 | 388.0 | False | None | None | False | None | False | 80075.44 | 0 | 2957731 | 97757 | None | Code08 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 229.75 | 229.75 | 260.0 | False | None | None | False | None | False | 59735.0 | 0 | 2957732 | 97757 | None | Code09 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 285.56 | 285.56 | 110.0 | False | None | None | False | None | False | 31411.6 | 0 | 2957733 | 97757 | None | Code10 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 338.78 | 338.78 | 150.0 | False | None | None | False | None | False | 50817.0 | 0 | 2957734 | 97757 | None | Code11 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 414.06 | 414.06 | 215.0 | False | None | None | False | None | False | 89022.9 | 0 | 2957735 | 97757 | None | Code12 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 Module ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 177.83 | 177.83 | 387.0 | False | None | None | False | None | False | 68820.21 | 0 | 2957736 | 97757 | None | Code13 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 208.98 | 208.98 | 388.0 | False | None | None | False | None | False | 81084.24 | 0 | 2957737 | 97757 | None | Code14 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 227.15 | 227.15 | 260.0 | False | None | None | False | None | False | 59059.0 | 0 | 2957738 | 97757 | None | Code15 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 303.73 | 303.73 | 110.0 | False | None | None | False | None | False | 33410.3 | 0 | 2957739 | 97757 | None | Code16 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 368.63 | 368.63 | 150.0 | False | None | None | False | None | False | 55294.5 | 0 | 2957740 | 97757 | None | Code17 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 446.51 | 446.51 | 215.0 | False | None | None | False | None | False | 95999.65 | 0 | 2957741 | 97757 | None | Code18 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way Switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 132.4 | 132.4 | 1462.0 | False | None | None | False | None | False | 193568.8 | 0 | 2957742 | 97757 | None | Code19 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way Switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 215.47 | 215.47 | 25.0 | False | None | None | False | None | False | 5386.75 | 0 | 2957743 | 97757 | None | Code20 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 221.96 | 221.96 | 325.0 | False | None | None | False | None | False | 72137.0 | 0 | 2957744 | 97757 | None | Code21 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 463.39 | 463.39 | 75.0 | False | None | None | False | None | False | 34754.25 | 0 | 2957745 | 97757 | None | Code22 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 423.15 | 423.15 | 75.0 | False | None | None | False | None | False | 31736.25 | 0 | 2957746 | 97757 | None | Code23 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 306.33 | 306.33 | 145.0 | False | None | None | False | None | False | 44417.85 | 0 | 2957747 | 97757 | None | Code24 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 233.64 | 233.64 | 145.0 | False | None | None | False | None | False | 33877.8 | 0 | 2957748 | 97757 | None | Code25 | Supplyin and Fixing Metal Fan Box with Round Hook. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 151.87 | 151.87 | 75.0 | False | None | None | False | None | False | 11390.25 | 0 | 2957749 | 97757 | None | Code26 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20Amps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1260.36 | 1260.36 | 2.0 | False | None | None | False | None | False | 2520.72 | 0 | 2957750 | 97757 | None | Code27 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30Amps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2206.6 | 2206.6 | 2.0 | False | None | None | False | None | False | 4413.2 | 0 | 2957751 | 97757 | None | Code28 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 85.67 | 85.67 | 7300.0 | False | None | None | False | None | False | 625391.0 | 0 | 2957752 | 97757 | None | Code29 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 101.24 | 101.24 | 14250.0 | False | None | None | False | None | False | 1442670.0 | 0 | 2957753 | 97757 | None | Code30 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 133.69 | 133.69 | 2250.0 | False | None | None | False | None | False | 300802.5 | 0 | 2957754 | 97757 | None | Code31 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 88.26 | 88.26 | 3450.0 | False | None | None | False | None | False | 304497.0 | 0 | 2957755 | 97757 | None | Code32 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 102.54 | 102.54 | 7250.0 | False | None | None | False | None | False | 743415.0 | 0 | 2957756 | 97757 | None | Code33 | Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 128.5 | 128.5 | 1050.0 | False | None | None | False | None | False | 134925.0 | 0 | 2957757 | 97757 | None | Code34 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 1.5 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 33.75 | 33.75 | 3750.0 | False | None | None | False | None | False | 126562.5 | 0 | 2957758 | 97757 | None | Code35 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 2.5 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 54.52 | 54.52 | 17250.0 | False | None | None | False | None | False | 940470.0 | 0 | 2957759 | 97757 | None | Code36 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 4 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 81.77 | 81.77 | 14500.0 | False | None | None | False | None | False | 1185665.0 | 0 | 2957760 | 97757 | None | Code37 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 6 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 119.42 | 119.42 | 7250.0 | False | None | None | False | None | False | 865795.0 | 0 | 2957761 | 97757 | None | Code38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest
amendments. 10 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 216.77 | 216.77 | 2000.0 | False | None | None | False | None | False | 433540.0 | 0 | 2957762 | 97757 | None | Code39 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 4 Way TP & N ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5241.32 | 5241.32 | 22.0 | False | None | None | False | None | False | 115309.04 | 0 | 2957763 | 97757 | None | Code40 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 6 Way TP & N ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6412.12 | 6412.12 | 20.0 | False | None | None | False | None | False | 128242.4 | 0 | 2957764 | 97757 | None | Code41 | Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way SP & N ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3023.04 | 3023.04 | 6.0 | False | None | None | False | None | False | 18138.24 | 0 | 2957765 | 97757 | None | Code42 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 650.0 | False | None | None | False | None | False | 350135.5 | 0 | 2957766 | 97757 | None | Code43 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3951.11 | 3951.11 | 22.0 | False | None | None | False | None | False | 86924.42 | 0 | 2957767 | 97757 | None | Code44 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 20.0 | False | None | None | False | None | False | 80164.4 | 0 | 2957768 | 97757 | None | Code45 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 959.22 | 959.22 | 6.0 | False | None | None | False | None | False | 5755.32 | 0 | 2957769 | 97757 | None | Code46 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 2 pole ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5917.58 | 5917.58 | 14.0 | False | None | None | False | None | False | 82846.12 | 0 | 2957770 | 97757 | None | Code47 | Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 32-40 Amps 4 pole ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6680.81 | 6680.81 | 22.0 | False | None | None | False | None | False | 146977.82 | 0 | 2957771 | 97757 | None | Code48 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7197.41 | 7197.41 | 20.0 | False | None | None | False | None | False | 143948.2 | 0 | 2957772 | 97757 | None | Code49 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 16 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 114766.56 | 114766.56 | 0.38 | False | None | None | False | None | False | 43611.2928 | 0 | 2957773 | 97757 | None | Code50 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 25 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 181134.6 | 181134.6 | 0.6 | False | None | None | False | None | False | 108680.76 | 0 | 2957774 | 97757 | None | Code51 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 35 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 199972.48 | 199972.48 | 0.35 | False | None | None | False | None | False | 69990.368 | 0 | 2957775 | 97757 | None | Code52 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 50 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 232306.95 | 232306.95 | 0.25 | False | None | None | False | None | False | 58076.7375 | 0 | 2957776 | 97757 | None | Code53 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 70 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 412649.78 | 412649.78 | 0.6 | False | None | None | False | None | False | 247589.868 | 0 | 2957777 | 97757 | None | Code54 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 95 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 484433.07 | 484433.07 | 0.25 | False | None | None | False | None | False | 121108.2675 | 0 | 2957778 | 97757 | None | Code55 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 120 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 593041.92 | 593041.92 | 0.1 | False | None | None | False | None | False | 59304.192 | 0 | 2957779 | 97757 | None | Code56 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 150 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 721240.19 | 721240.19 | 0.05 | False | None | None | False | None | False | 36062.0095 | 0 | 2957780 | 97757 | None | Code57 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 185 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 897200.96 | 897200.96 | 0.05 | False | None | None | False | None | False | 44860.048 | 0 | 2957781 | 97757 | None | Code58 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 240 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 1119740.47 | 1119740.47 | 0.06 | False | None | None | False | None | False | 67184.4282 | 0 | 2957782 | 97757 | None | Code59 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 3.5 core 300 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 1383686.17 | 1383686.17 | 0.85 | False | None | None | False | None | False | 1176133.2445 | 0 | 2957783 | 97757 | None | Code60 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 sqmm to 25 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 27110.03 | 27110.03 | 1.0 | False | None | None | False | None | False | 27110.03 | 0 | 2957784 | 97757 | None | Code61 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 sqmm to 95 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 40418.42 | 40418.42 | 1.45 | False | None | None | False | None | False | 58606.709 | 0 | 2957785 | 97757 | None | Code62 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 120 sqmm to 300 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 41896.84 | 41896.84 | 1.11 | False | None | None | False | None | False | 46505.4924 | 0 | 2957786 | 97757 | None | Code63 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 32mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 151.87 | 151.87 | 25.0 | False | None | None | False | None | False | 3796.75 | 0 | 2957787 | 97757 | None | Code64 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 63mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 503.62 | 503.62 | 28.0 | False | None | None | False | None | False | 14101.36 | 0 | 2957788 | 97757 | None | Code65 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 45mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 251.81 | 251.81 | 35.0 | False | None | None | False | None | False | 8813.35 | 0 | 2957789 | 97757 | None | Code66 | Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 75mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 643.81 | 643.81 | 45.0 | False | None | None | False | None | False | 28971.45 | 0 | 2957790 | 97757 | None | Code67 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 16 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 16.15 | 16.15 | 32.0 | False | None | None | False | None | False | 516.8 | 0 | 2957791 | 97757 | None | Code68 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 25 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 25.96 | 25.96 | 32.0 | False | None | None | False | None | False | 830.72 | 0 | 2957792 | 97757 | None | Code69 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 41.54 | 41.54 | 54.0 | False | None | None | False | None | False | 2243.16 | 0 | 2957793 | 97757 | None | Code70 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 50 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 77.88 | 77.88 | 32.0 | False | None | None | False | None | False | 2492.16 | 0 | 2957794 | 97757 | None | Code71 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 70 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 155.76 | 155.76 | 48.0 | False | None | None | False | None | False | 7476.48 | 0 | 2957795 | 97757 | None | Code72 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 95 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 194.7 | 194.7 | 32.0 | False | None | None | False | None | False | 6230.4 | 0 | 2957796 | 97757 | None | Code73 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 120 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 246.62 | 246.62 | 16.0 | False | None | None | False | None | False | 3945.92 | 0 | 2957797 | 97757 | None | Code74 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 185 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 424.45 | 424.45 | 16.0 | False | None | None | False | None | False | 6791.2 | 0 | 2957798 | 97757 | None | Code75 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 240 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 600.97 | 600.97 | 24.0 | False | None | None | False | None | False | 14423.28 | 0 | 2957799 | 97757 | None | Code76 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 300 sqmm Long Barrel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 813.85 | 813.85 | 64.0 | False | None | None | False | None | False | 52086.4 | 0 | 2957800 | 97757 | None | Code77 | Earth work excavation for cable trench of 0.5 to 0.75 mtr. Width and Depth upto 1 mtr including trial pits, depositing on bank upto a lead of 50 mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 mtr wherever necessary as directed- In hard soil ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | cm | 504.92 | 504.92 | 300.0 | False | None | None | False | None | False | 151476.0 | 0 | 2957801 | 97757 | None | Code78 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 4555.98 | 4555.98 | 22.0 | False | None | None | False | None | False | 100231.56 | 0 | 2957802 | 97757 | None | Code79 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 106.44 | 106.44 | 730.0 | False | None | None | False | None | False | 77701.2 | 0 | 2957803 | 97757 | None | Code80 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 166.14 | 166.14 | 630.0 | False | None | None | False | None | False | 104668.2 | 0 | 2957804 | 97757 | None | Code81 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm GI strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 234.94 | 234.94 | 50.0 | False | None | None | False | None | False | 11747.0 | 0 | 2957805 | 97757 | None | Code82 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 739.86 | 739.86 | 200.0 | False | None | None | False | None | False | 147972.0 | 0 | 2957806 | 97757 | None | Code83 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm Copper strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1427.8 | 1427.8 | 150.0 | False | None | None | False | None | False | 214170.0 | 0 | 2957807 | 97757 | None | Code84 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm GI plate ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1135.75 | 1135.75 | 10.0 | False | None | None | False | None | False | 11357.5 | 0 | 2957808 | 97757 | None | Code85 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plate ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9632.46 | 9632.46 | 14.0 | False | None | None | False | None | False | 134854.44 | 0 | 2957809 | 97757 | None | Code86 | Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 150x50mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 551.65 | 551.65 | 500.0 | False | None | None | False | None | False | 275825.0 | 0 | 2957810 | 97757 | None | Code87 | Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 300x50mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 687.94 | 687.94 | 150.0 | False | None | None | False | None | False | 103191.0 | 0 | 2957811 | 97757 | None | Code88 | Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 450x50mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1061.76 | 1061.76 | 30.0 | False | None | None | False | None | False | 31852.8 | 0 | 2957812 | 97757 | None | Code89 | Supplying and fixing 2mm thick perforated cable tray with powder coated paint on existing MS angle support using necessary Gl bolts/nuts and washer or welding as required 600x50mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1122.77 | 1122.77 | 30.0 | False | None | None | False | None | False | 33683.1 | 0 | 2957813 | 97757 | None | Code90 | Supply and installation of Bedded Panel with 4 no's 6 amps sockets and 4 no's 16 amps sockets with switches and 6 watt LED light fixtures & Provision for 4Nos gas pipeline sockets. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 10030.0 | 10030.0 | 106.0 | False | None | None | False | None | False | 1063180.0 | 0 | 2957814 | 97757 | None | Code91 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1148.73 | 1148.73 | 275.0 | False | None | None | False | None | False | 315900.75 | 0 | 2957815 | 97757 | None | Code92 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1718.55 | 1718.55 | 325.0 | False | None | None | False | None | False | 558528.75 | 0 | 2957816 | 97757 | None | Code93 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 895.62 | 895.62 | 172.0 | False | None | None | False | None | False | 154046.64 | 0 | 2957817 | 97757 | None | Code94 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 7 W, 6500K ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 193.4 | 193.4 | 25.0 | False | None | None | False | None | False | 4835.0 | 0 | 2957818 | 97757 | None | Code95 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 349.16 | 349.16 | 50.0 | False | None | None | False | None | False | 17458.0 | 0 | 2957819 | 97757 | None | Code96 | Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 34 -36watt ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5909.79 | 5909.79 | 160.0 | False | None | None | False | None | False | 945566.4 | 0 | 2957820 | 97757 | None | Code97 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 7777.62 | 7777.62 | 5.0 | False | None | None | False | None | False | 38888.1 | 0 | 2957821 | 97757 | None | Code98 | Supplying exhaust fan of 1440 RPM of 300mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1936.62 | 1936.62 | 45.0 | False | None | None | False | None | False | 87147.9 | 0 | 2957822 | 97757 | None | Code99 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 15" Sweep (450mm) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5355.55 | 5355.55 | 4.0 | False | None | None | False | None | False | 21422.2 | 0 | 2957823 | 97757 | None | Code100 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48" Sweep 5 Star (1200 mm) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3474.75 | 3474.75 | 75.0 | False | None | None | False | None | False | 260606.25 | 0 | 2957824 | 97757 | None | Code101 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply. 300mm Sweep ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3234.62 | 3234.62 | 20.0 | False | None | None | False | None | False | 64692.4 | 0 | 2957825 | 97757 | None | Code102 | Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 81.77 | 81.77 | 75.0 | False | None | None | False | None | False | 6132.75 | 0 | 2957826 | 97757 | None | Code103 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 158.36 | 158.36 | 1042.0 | False | None | None | False | None | False | 165011.12 | 0 | 2957827 | 97757 | None | Code104 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size
wooden board and wired. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 408.87 | 408.87 | 95.0 | False | None | None | False | None | False | 38842.65 | 0 | 2957828 | 97757 | None | Code105 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 917.69 | 917.69 | 50.0 | False | None | None | False | None | False | 45884.5 | 0 | 2957829 | 97757 | None | Code106 | Supplying and fixing one of 230 volts Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 319.31 | 319.31 | 10.0 | False | None | None | False | None | False | 3193.1 | 0 | 2957830 | 97757 | None | Code107 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 mtr. Length ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1896.38 | 1896.38 | 5.0 | False | None | None | False | None | False | 9481.9 | 0 | 2957831 | 97757 | None | Code108 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 210.28 | 210.28 | 5.0 | False | None | None | False | None | False | 1051.4 | 0 | 2957832 | 97757 | None | Code109 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.65 | 0.65 | 2250000.0 | False | None | None | False | None | False | 1462500.0 | 0 | 2957833 | 97757 | None | Code110 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000 A double run of 4 x 60 x 10 mm Aluminium Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 13732.84 | 13732.84 | 22.0 | False | None | None | False | None | False | 302122.48 | 0 | 2957834 | 97757 | None | Code111 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 40.0 | False | None | None | False | None | False | 28815.6 | 0 | 2957835 | 97757 | None | Code112 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 40.0 | False | None | None | False | None | False | 48078.0 | 0 | 2957836 | 97757 | None | Code113 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 6.0 | False | None | None | False | None | False | 66096.78 | 0 | 2957837 | 97757 | None | Code114 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA125Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 13422.62 | 13422.62 | 3.0 | False | None | None | False | None | False | 40267.86 | 0 | 2957838 | 97757 | None | Code115 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 160Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 17454.21 | 17454.21 | 4.0 | False | None | None | False | None | False | 69816.84 | 0 | 2957839 | 97757 | None | Code116 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 250Amps 35kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 27765.52 | 27765.52 | 1.0 | False | None | None | False | None | False | 27765.52 | 0 | 2957840 | 97757 | None | Code117 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 39084.08 | 39084.08 | 3.0 | False | None | None | False | None | False | 117252.24 | 0 | 2957841 | 97757 | None | Code118 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 700-800Amps 50kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 64770.2 | 64770.2 | 1.0 | False | None | None | False | None | False | 64770.2 | 0 | 2957842 | 97757 | None | Code119 | Supply and fixing of fully Enclosed 400A Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,.Adjustable Time Delay(0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 Volts ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 115640.0 | 115640.0 | 1.0 | False | None | None | False | None | False | 115640.0 | 0 | 2957843 | 97757 | None | Code120 | Supplying and fixing of 800A, FP, 50kA, microprocessor based Motorised ACB electrical drawout type.over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 141600.0 | 141600.0 | 2.0 | False | None | None | False | None | False | 283200.0 | 0 | 2957844 | 97757 | None | Code121 | Supplying and fixing of 630A, FP, 50kA, microprocessor based Motorised ACB electrical drawout type.over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 106200.0 | 106200.0 | 2.0 | False | None | None | False | None | False | 212400.0 | 0 | 2957845 | 97757 | None | Code122 | Bus Coupler 1000A, FP, 50kA, microprocessor based ACB electrical drawout type, motorised with PLC out protection ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 153400.0 | 153400.0 | 1.0 | False | None | None | False | None | False | 153400.0 | 0 | 2957846 | 97757 | None | Code123 | Supplying and fixing of 800A, FP, 50kA, microprocessor based Motorised ACB electrical drawout type.over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 177000.0 | 177000.0 | 1.0 | False | None | None | False | None | False | 177000.0 | 0 | 2957847 | 97757 | None | Code124 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12012.99 | 12012.99 | 4.0 | False | None | None | False | None | False | 48051.96 | 0 | 2957848 | 97757 | None | Code125 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 4.0 | False | None | None | False | None | False | 48363.48 | 0 | 2957849 | 97757 | None | Code126 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 24.0 | False | None | None | False | None | False | 16043.28 | 0 | 2957850 | 97757 | None | Code127 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 4.0 | False | None | None | False | None | False | 2917.92 | 0 | 2957851 | 97757 | None | Code128 | Suppiying and fixing of Shunt trip suitable for MCCB.CBCT ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2210.49 | 2210.49 | 4.0 | False | None | None | False | None | False | 8841.96 | 0 | 2957852 | 97757 | None | Code129 | Supplying,fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1090.32 | 1090.32 | 18.0 | False | None | None | False | None | False | 19625.76 | 0 | 2957853 | 97757 | None | Code130 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32A SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 12.0 | False | None | None | False | None | False | 6464.04 | 0 | 2957854 | 97757 | None | Code131 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 1000000.0 | False | None | None | False | None | False | 560000.0 | 0 | 2957855 | 97757 | None | Code132 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400Amps 4x50x10mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 5769.61 | 5769.61 | 16.0 | False | None | None | False | None | False | 92313.76 | 0 | 2957856 | 97757 | None | Code133 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x50x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 512.71 | 512.71 | 30.0 | False | None | None | False | None | False | 15381.3 | 0 | 2957857 | 97757 | None | Code134 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 981.29 | 981.29 | 30.0 | False | None | None | False | None | False | 29438.7 | 0 | 2957858 | 97757 | None | Code135 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Therm IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE320-400Amps 50kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 39084.08 | 39084.08 | 2.0 | False | None | None | False | None | False | 78168.16 | 0 | 2957859 | 97757 | None | Code136 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3951.11 | 3951.11 | 10.0 | False | None | None | False | None | False | 39511.1 | 0 | 2957860 | 97757 | None | Code137 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 10.0 | False | None | None | False | None | False | 40082.2 | 0 | 2957861 | 97757 | None | Code138 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 6.0 | False | None | None | False | None | False | 3232.02 | 0 | 2957862 | 97757 | None | Code139 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 2.0 | False | None | None | False | None | False | 24181.74 | 0 | 2957863 | 97757 | None | Code140 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 6.0 | False | None | None | False | None | False | 4010.82 | 0 | 2957864 | 97757 | None | Code141 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 6.0 | False | None | None | False | None | False | 4376.88 | 0 | 2957865 | 97757 | None | Code142 | Supplying, fixing and wiring Automatic Power Factor controller fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three place LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect I disconnect banks, with automatic recognition or with standard programs. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 28088.72 | 28088.72 | 2.0 | False | None | None | False | None | False | 56177.44 | 0 | 2957866 | 97757 | None | Code143 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinery ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kvar | 623.04 | 623.04 | 300.0 | False | None | None | False | None | False | 186912.0 | 0 | 2957867 | 97757 | None | Code144 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 25 Amps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1674.42 | 1674.42 | 10.0 | False | None | None | False | None | False | 16744.2 | 0 | 2957868 | 97757 | None | Code145 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 40 Amps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2930.88 | 2930.88 | 10.0 | False | None | None | False | None | False | 29308.8 | 0 | 2957869 | 97757 | None | Code146 | Supplying , & fixing of 6A, 3 Position, Auto-Manual Selector Switch in existing Panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 531.0 | 531.0 | 16.0 | False | None | None | False | None | False | 8496.0 | 0 | 2957870 | 97757 | None | Code147 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 576000.0 | False | None | None | False | None | False | 322560.0 | 0 | 2957871 | 97757 | None | Code148 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 3199.57 | 3199.57 | 5.0 | False | None | None | False | None | False | 15997.85 | 0 | 2957872 | 97757 | None | Code149 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 4458.63 | 4458.63 | 15.0 | False | None | None | False | None | False | 66879.45 | 0 | 2957873 | 97757 | None | Code150 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 395.89 | 395.89 | 12.0 | False | None | None | False | None | False | 4750.68 | 0 | 2957874 | 97757 | None | Code151 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 981.29 | 981.29 | 12.0 | False | None | None | False | None | False | 11775.48 | 0 | 2957875 | 97757 | None | Code152 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 2.0 | False | None | None | False | None | False | 22032.26 | 0 | 2957876 | 97757 | None | Code153 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 160Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 17454.21 | 17454.21 | 3.0 | False | None | None | False | None | False | 52362.63 | 0 | 2957877 | 97757 | None | Code154 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 12.0 | False | None | None | False | None | False | 6464.04 | 0 | 2957878 | 97757 | None | Code155 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 959.22 | 959.22 | 5.0 | False | None | None | False | None | False | 4796.1 | 0 | 2957879 | 97757 | None | Code156 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 33.0 | False | None | None | False | None | False | 132271.26 | 0 | 2957880 | 97757 | None | Code157 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 4.0 | False | None | None | False | None | False | 48363.48 | 0 | 2957881 | 97757 | None | Code158 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 12.0 | False | None | None | False | None | False | 8021.64 | 0 | 2957882 | 97757 | None | Code159 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 12.0 | False | None | None | False | None | False | 8753.76 | 0 | 2957883 | 97757 | None | Code160 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 230000.0 | False | None | None | False | None | False | 128800.0 | 0 | 2957884 | 97757 | None | Code161 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 4458.63 | 4458.63 | 12.0 | False | None | None | False | None | False | 53503.56 | 0 | 2957885 | 97757 | None | Code162 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 24.0 | False | None | None | False | None | False | 17289.36 | 0 | 2957886 | 97757 | None | Code163 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 24.0 | False | None | None | False | None | False | 28846.8 | 0 | 2957887 | 97757 | None | Code164 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 2.0 | False | None | None | False | None | False | 22032.26 | 0 | 2957888 | 97757 | None | Code165 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA125Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 13422.62 | 13422.62 | 2.0 | False | None | None | False | None | False | 26845.24 | 0 | 2957889 | 97757 | None | Code166 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA 250Amps 36kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 30561.41 | 30561.41 | 1.0 | False | None | None | False | None | False | 30561.41 | 0 | 2957890 | 97757 | None | Code167 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 3.0 | False | None | None | False | None | False | 1616.01 | 0 | 2957891 | 97757 | None | Code168 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 5.0 | False | None | None | False | None | False | 20041.1 | 0 | 2957892 | 97757 | None | Code169 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 959.22 | 959.22 | 2.0 | False | None | None | False | None | False | 1918.44 | 0 | 2957893 | 97757 | None | Code170 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 1.0 | False | None | None | False | None | False | 12090.87 | 0 | 2957894 | 97757 | None | Code171 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 3.0 | False | None | None | False | None | False | 2005.41 | 0 | 2957895 | 97757 | None | Code172 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 3.0 | False | None | None | False | None | False | 2188.44 | 0 | 2957896 | 97757 | None | Code173 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 455000.0 | False | None | None | False | None | False | 254800.0 | 0 | 2957897 | 97757 | None | Code174 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100Amps 4x30x6mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 3199.57 | 3199.57 | 8.0 | False | None | None | False | None | False | 25596.56 | 0 | 2957898 | 97757 | None | Code175 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 4458.63 | 4458.63 | 12.0 | False | None | None | False | None | False | 53503.56 | 0 | 2957899 | 97757 | None | Code176 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 395.89 | 395.89 | 35.0 | False | None | None | False | None | False | 13856.15 | 0 | 2957900 | 97757 | None | Code177 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 981.29 | 981.29 | 35.0 | False | None | None | False | None | False | 34345.15 | 0 | 2957901 | 97757 | None | Code178 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 1.0 | False | None | None | False | None | False | 11016.13 | 0 | 2957902 | 97757 | None | Code179 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 125Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 13422.62 | 13422.62 | 2.0 | False | None | None | False | None | False | 26845.24 | 0 | 2957903 | 97757 | None | Code180 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 9.0 | False | None | None | False | None | False | 4848.03 | 0 | 2957904 | 97757 | None | Code181 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps DP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 959.22 | 959.22 | 4.0 | False | None | None | False | None | False | 3836.88 | 0 | 2957905 | 97757 | None | Code182 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 15.0 | False | None | None | False | None | False | 60123.3 | 0 | 2957906 | 97757 | None | Code183 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 3.0 | False | None | None | False | None | False | 36272.61 | 0 | 2957907 | 97757 | None | Code184 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 9.0 | False | None | None | False | None | False | 6016.23 | 0 | 2957908 | 97757 | None | Code185 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 9.0 | False | None | None | False | None | False | 6565.32 | 0 | 2957909 | 97757 | None | Code186 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 376000.0 | False | None | None | False | None | False | 210560.0 | 0 | 2957910 | 97757 | None | Code187 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400 A 4 x 50 x 10 mm Aluminium Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 5769.61 | 5769.61 | 16.0 | False | None | None | False | None | False | 92313.76 | 0 | 2957911 | 97757 | None | Code188 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 20.0 | False | None | None | False | None | False | 14407.8 | 0 | 2957912 | 97757 | None | Code189 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 20.0 | False | None | None | False | None | False | 24039.0 | 0 | 2957913 | 97757 | None | Code190 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 5.0 | False | None | None | False | None | False | 55080.65 | 0 | 2957914 | 97757 | None | Code191 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 500-630Amps 36kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 54384.9 | 54384.9 | 2.0 | False | None | None | False | None | False | 108769.8 | 0 | 2957915 | 97757 | None | Code192 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 3.0 | False | None | None | False | None | False | 1616.01 | 0 | 2957916 | 97757 | None | Code193 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 2.0 | False | None | None | False | None | False | 8016.44 | 0 | 2957917 | 97757 | None | Code194 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 2.0 | False | None | None | False | None | False | 24181.74 | 0 | 2957918 | 97757 | None | Code195 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 6.0 | False | None | None | False | None | False | 4010.82 | 0 | 2957919 | 97757 | None | Code196 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 6.0 | False | None | None | False | None | False | 4376.88 | 0 | 2957920 | 97757 | None | Code197 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 445000.0 | False | None | None | False | None | False | 249200.0 | 0 | 2957921 | 97757 | None | Code198 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 3199.57 | 3199.57 | 20.0 | False | None | None | False | None | False | 63991.4 | 0 | 2957922 | 97757 | None | Code199 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 395.89 | 395.89 | 40.0 | False | None | None | False | None | False | 15835.6 | 0 | 2957923 | 97757 | None | Code200 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 981.29 | 981.29 | 40.0 | False | None | None | False | None | False | 39251.6 | 0 | 2957924 | 97757 | None | Code201 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 4.0 | False | None | None | False | None | False | 44064.52 | 0 | 2957925 | 97757 | None | Code202 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 12.0 | False | None | None | False | None | False | 6464.04 | 0 | 2957926 | 97757 | None | Code203 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2228.67 | 2228.67 | 4.0 | False | None | None | False | None | False | 8914.68 | 0 | 2957927 | 97757 | None | Code204 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3951.11 | 3951.11 | 10.0 | False | None | None | False | None | False | 39511.1 | 0 | 2957928 | 97757 | None | Code205 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 10.0 | False | None | None | False | None | False | 40082.2 | 0 | 2957929 | 97757 | None | Code206 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 3.0 | False | None | None | False | None | False | 36272.61 | 0 | 2957930 | 97757 | None | Code207 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 9.0 | False | None | None | False | None | False | 6016.23 | 0 | 2957931 | 97757 | None | Code208 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 9.0 | False | None | None | False | None | False | 6565.32 | 0 | 2957932 | 97757 | None | Code209 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 440000.0 | False | None | None | False | None | False | 246400.0 | 0 | 2957933 | 97757 | None | Code210 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.600 A 4 x 75 x 10 mm Aluminium Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 7301.25 | 7301.25 | 8.0 | False | None | None | False | None | False | 58410.0 | 0 | 2957934 | 97757 | None | Code211 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 16.0 | False | None | None | False | None | False | 11526.24 | 0 | 2957935 | 97757 | None | Code212 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 16.0 | False | None | None | False | None | False | 19231.2 | 0 | 2957936 | 97757 | None | Code213 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 500- 630Amps 50kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 54384.9 | 54384.9 | 1.0 | False | None | None | False | None | False | 54384.9 | 0 | 2957937 | 97757 | None | Code214 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 10.0 | False | None | None | False | None | False | 110161.3 | 0 | 2957938 | 97757 | None | Code215 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 3.0 | False | None | None | False | None | False | 1616.01 | 0 | 2957939 | 97757 | None | Code216 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4008.22 | 4008.22 | 8.0 | False | None | None | False | None | False | 32065.76 | 0 | 2957940 | 97757 | None | Code217 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 1.0 | False | None | None | False | None | False | 12090.87 | 0 | 2957941 | 97757 | None | Code218 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 3.0 | False | None | None | False | None | False | 2005.41 | 0 | 2957942 | 97757 | None | Code219 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 3.0 | False | None | None | False | None | False | 2188.44 | 0 | 2957943 | 97757 | None | Code220 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 220000.0 | False | None | None | False | None | False | 123200.0 | 0 | 2957944 | 97757 | None | Code221 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250 A 4 x 30 x 10 mm Aluminium Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 3199.57 | 3199.57 | 8.0 | False | None | None | False | None | False | 25596.56 | 0 | 2957945 | 97757 | None | Code222 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 395.89 | 395.89 | 16.0 | False | None | None | False | None | False | 6334.24 | 0 | 2957946 | 97757 | None | Code223 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 981.29 | 981.29 | 16.0 | False | None | None | False | None | False | 15700.64 | 0 | 2957947 | 97757 | None | Code224 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 125 A 25 kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 13422.62 | 13422.62 | 1.0 | False | None | None | False | None | False | 13422.62 | 0 | 2957948 | 97757 | None | Code225 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 5.0 | False | None | None | False | None | False | 55080.65 | 0 | 2957949 | 97757 | None | Code226 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 3.0 | False | None | None | False | None | False | 1616.01 | 0 | 2957950 | 97757 | None | Code227 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 1.0 | False | None | None | False | None | False | 12090.87 | 0 | 2957951 | 97757 | None | Code228 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 3.0 | False | None | None | False | None | False | 2005.41 | 0 | 2957952 | 97757 | None | Code229 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 3.0 | False | None | None | False | None | False | 2188.44 | 0 | 2957953 | 97757 | None | Code230 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 180000.0 | False | None | None | False | None | False | 100800.0 | 0 | 2957954 | 97757 | None | Code231 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 250Amps 4x30x10mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 4458.63 | 4458.63 | 10.0 | False | None | None | False | None | False | 44586.3 | 0 | 2957955 | 97757 | None | Code232 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 395.89 | 395.89 | 20.0 | False | None | None | False | None | False | 7917.8 | 0 | 2957956 | 97757 | None | Code233 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 981.29 | 981.29 | 20.0 | False | None | None | False | None | False | 19625.8 | 0 | 2957957 | 97757 | None | Code234 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 5.0 | False | None | None | False | None | False | 55080.65 | 0 | 2957958 | 97757 | None | Code235 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR POLE 160Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 17454.21 | 17454.21 | 1.0 | False | None | None | False | None | False | 17454.21 | 0 | 2957959 | 97757 | None | Code236 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 9.0 | False | None | None | False | None | False | 4848.03 | 0 | 2957960 | 97757 | None | Code237 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps TPN ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2228.67 | 2228.67 | 24.0 | False | None | None | False | None | False | 53488.08 | 0 | 2957961 | 97757 | None | Code238 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired ajter fixing to the existing wooden board for motor Upto 12.5 HP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9676.59 | 9676.59 | 24.0 | False | None | None | False | None | False | 232238.16 | 0 | 2957962 | 97757 | None | Code239 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 3.0 | False | None | None | False | None | False | 36272.61 | 0 | 2957963 | 97757 | None | Code240 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 9.0 | False | None | None | False | None | False | 6016.23 | 0 | 2957964 | 97757 | None | Code241 | Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape Wound ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 729.48 | 729.48 | 9.0 | False | None | None | False | None | False | 6565.32 | 0 | 2957965 | 97757 | None | Code242 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 220000.0 | False | None | None | False | None | False | 123200.0 | 0 | 2957966 | 97757 | None | Code243 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100Amps 25kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11016.13 | 11016.13 | 10.0 | False | None | None | False | None | False | 110161.3 | 0 | 2957967 | 97757 | None | Code244 | STREET LIGHTING PANEL-Fabricating, Supplying & Mounting M.S. Box made out of 16 SWG of size 700x750x220mm suitable for floor / wall mounting, fully weather proof with provision for better heat desipation, with two chambers & window for energy meter, provided with hinged front cover, two inside doors, with tamper proof locking arrangments, suitable size clamps with necessary cable entry pipe with gland and box should be finished with two coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. The box should be mounted on M.S.angle iron of size 40x40x6mm (total length 4.7 mtr) with 1:2:4 concreting (0.25x0.75x0.9 mtr) including coping. provision for housing 3 phase energy meter, suitable size bus bar, 100 A cut out (3 Nos), with timer (3-120sec) & contactorc) (60-70Amps), 63 A MCB TPN (1 No), 2 Nos 32 A TPN MCB on 4mm thick hylum sheet, wiring with suitable size copper wire & lugs. The box should be earthed with pipe type earthing. (AS PER PWD SR) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 59000.0 | 59000.0 | 1.0 | False | None | None | False | None | False | 59000.0 | 0 | 2957968 | 97757 | None | Code245 | Fabricating, supplying and erecting swaged tubular pole of height …mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 20119.0 | 20119.0 | 10.0 | False | None | None | False | None | False | 201190.0 | 0 | 2957969 | 97757 | None | Code246 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70watts ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 7777.62 | 7777.62 | 10.0 | False | None | None | False | None | False | 77776.2 | 0 | 2957970 | 97757 | None | Code247 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 mtr. Length ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1896.38 | 1896.38 | 10.0 | False | None | None | False | None | False | 18963.8 | 0 | 2957971 | 97757 | None | Code248 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 210.28 | 210.28 | 10.0 | False | None | None | False | None | False | 2102.8 | 0 | 2957972 | 97757 | None | Code249 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 153169.19 | 153169.19 | 0.25 | False | None | None | False | None | False | 38292.2975 | 0 | 2957973 | 97757 | None | Code250 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as
directed by the departmental staff 2.5 Sqmm to 25 sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 27110.03 | 27110.03 | 0.2 | False | None | None | False | None | False | 5422.006 | 0 | 2957974 | 97757 | None | Code251 | Supplying and fixing Parallel Connectors for (500mm air terminal) connecting two conductors in parallel manner. Material- StSt, with clamping range- Rd / Rd 7-10 mm & Complied as per Standard EN 62561-1. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1413.64 | 1413.64 | 10.0 | False | None | None | False | None | False | 14136.4 | 0 | 2957975 | 97757 | None | Code252 | Supplying and fixing Air-termination rod having length- 3000 mm, of Material- AlMgSi, of Diameter 16 / 10 mm, chamfered on both ends & Complied as per Standard EN 62561-2. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 5607.36 | 5607.36 | 5.0 | False | None | None | False | None | False | 28036.8 | 0 | 2957976 | 97757 | None | Code253 | Supplying and fixing Side Wall Clamp for air terminal, Material - StSt 304 Clamping range - 16/10 mm. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2102.76 | 2102.76 | 10.0 | False | None | None | False | None | False | 21027.6 | 0 | 2957977 | 97757 | None | Code254 | Supplying and fixing Air-termination rod clamps for connecting air-termination rods with one or two conductors. Material of clamp Al, with clamping range of air-termination rod 16 mm and Clamping range of conductor Rd 2x 8-10 mm & Complied as per Standard EN 62561-1. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 830.72 | 830.72 | 5.0 | False | None | None | False | None | False | 4153.6 | 0 | 2957978 | 97757 | None | Code255 | Supplying and fixing MV clamp with hexagon screw, StSt MV clamp Multipurpose connecting clamp for universal use as a cross clamp, T clamp and parallel clamp, for round conductors ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 988.84 | 988.84 | 40.0 | False | None | None | False | None | False | 39553.6 | 0 | 2957979 | 97757 | None | Code256 | Supplying and fixing Connecting Sleeves for longitudinal connection of two round conductors with four screws. Material of clamp- Al, Clamping range- Rd 8 mm & Complied as per Standard EN 62561-1. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 624.22 | 624.22 | 120.0 | False | None | None | False | None | False | 74906.4 | 0 | 2957980 | 97757 | None | Code257 | Supplying and fixing Roof Conductor of Diameter - 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 410.64 | 410.64 | 600.0 | False | None | None | False | None | False | 246384.0 | 0 | 2957981 | 97757 | None | Code258 | Supplying and fixing Roof conductor holder FB2 for flat roofs with concrete block-C35/45 with double conductor holder- Rd 8 mm fixed, Dimension- 141 x 86 x 70 mm. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 440.14 | 440.14 | 25.0 | False | None | None | False | None | False | 11003.5 | 0 | 2957982 | 97757 | None | Code259 | Supplying and fixing Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- plastic, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 278.48 | 278.48 | 600.0 | False | None | None | False | None | False | 167088.0 | 0 | 2957983 | 97757 | None | Code260 | Supplying and fixing Down Conductor of Diameter - 8 mm, Cross-section- 50 mm2, of Material- AlMgSi & Complied as per Standard EN 62561-2. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 427.16 | 427.16 | 500.0 | False | None | None | False | None | False | 213580.0 | 0 | 2957984 | 97757 | None | Code261 | Supplying and fixing Conductor holder for Parapet wall/Side wall. Having height- 16 mm, Thread of conductor holder- M8, Material of conductor holder- plastic, Conductor leading- loose, Conductor holder support Rd- 8 mm With accessories Screw and Gitty, Material SS (M5 x 50mm) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 311.52 | 311.52 | 500.0 | False | None | None | False | None | False | 155760.0 | 0 | 2957985 | 97757 | None | Code262 | Supplying and fixing Lightning strike counter, Lightning strike counter for digitally recording impulse currents. The counter is preferably installed on the down conductors of the lightning protection system or between the equipotential bonding bar and the earth- termination system. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 63853.34 | 63853.34 | 1.0 | False | None | None | False | None | False | 63853.34 | 0 | 2957986 | 97757 | None | Code263 | Supplying and fixing UNI Disconnecting Clamps with intermediate plate for round and flat conductor of Material- StSt, Material thickness- 2.5 mm, with clamping range- Rd / Fl 8-10 / 30 mm, & Complied as per Standard EN 62561-1. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1477.36 | 1477.36 | 20.0 | False | None | None | False | None | False | 29547.2 | 0 | 2957987 | 97757 | None | Code264 | Supplying and fixing GI flat (25x6mm) Strip. Having width- 25mm, Thickness- 6mm, Material- Hot dipped Galvanized Iron, Cross Section- 150 mm2 Coating thickness- Avg. 70 microns. & Complied as per IEC 62561-2. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 640.74 | 640.74 | 160.0 | False | None | None | False | None | False | 102518.4 | 0 | 2957988 | 97757 | None | Code265 | Supplying and fixing GI strip holder of material- Dow moulded compound, having height- 19mm, Slot Size- 25x6 mm. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 772.9 | 772.9 | 50.0 | False | None | None | False | None | False | 38645.0 | 0 | 2957989 | 97757 | None | Code266 | Supplying and fixing Copper bonded rod with Low carbon steel, high tensile strength copper bonded rod with min 254 microns of copper plating, UL listed with company name marked on rod. Diameter- 17.2 mm, Length- 3 meters, Material- Copper Bonded, Coating thickness- 250 microns, min, Approvals- Tested acc. IEC / EN 62561-2, UL 467. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11742.18 | 11742.18 | 20.0 | False | None | None | False | None | False | 234843.6 | 0 | 2957990 | 97757 | None | Code267 | Supplying and fixing Environment friendly, RoHS certified, low resistivity Ground Enhancement material in 22.6 Kg pack to fill the bore area around the rod. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11742.18 | 11742.18 | 20.0 | False | None | None | False | None | False | 234843.6 | 0 | 2957991 | 97757 | None | Code268 | Supplying and fixing StSt 316 grade clamp to terminate the load on earth electrode. Dimension- 160x35x3 mm. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1642.56 | 1642.56 | 20.0 | False | None | None | False | None | False | 32851.2 | 0 | 2957992 | 97757 | None | Code269 | Supplying and fixing Poly plastic pit cover of material- Polymer Body & Cover, Product Code- HEP, Dimensions- 308 mm (L) x 308 mm (W) X 214 mm (H), Weight 2.5 kg (5.50 LBS). ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4106.4 | 4106.4 | 20.0 | False | None | None | False | None | False | 82128.0 | 0 | 2957993 | 97757 | None | Code270 | Supply of 08 KVA Isolated Power Distribution panel for OT with Online monitoring, with fault location and with Programmable Remote Alarm Indicator :
Electrical Safety system: IEC 60364-7-710: “Electrical installation ofbuildings-Requirements for special installations for medical locations”( Group-2) and Indian NEC- SP-30- Section 4, 2011, provision P5 requires unearthed(IT) system for all critical medical locations ( O.T, I.C.U, I.C.C.U, PrematureBaby Room etc). Therefore, an Electrical Safety Alarm System shall beinstalled to ensure patient and employee safety against risk of electrical shock, fire and damage of electrical insulation used in equipment and powerdistribution circuits. The system shall provide perfect ungrounded powersupply system in OT; ensure no fire, no electrical spark, no MCB tripping evenin case of 1st insulation fault (BIS NEC-SP-30 , P5 location requirement);ensure 24X7 Insulation monitoring of entire electrical distribution system &an audio visual remote and local alarm even in case of 1st fault; never give anyspurious alarm / false alarm, fool proof against EMI/EMC effects; should havea system to identify faulty feeder / socket / equipment online without trippingthe system; a periodic self diagnostic features to identify malfunctions in thesystem itself. Insulation monitoring devices using a Active measuring principle in compliance with IEC 61557-8&IEC-60364-7-710 should be used.Insulation monitor shall have facility to monitor over current and temperature monitoring facility of the Isolation transformer.Fault Location system should be in accordance with IEC 61557-9 & IEC 60364-7-710. a.An Isolation Transformer 10KVA max as per IEC-61558-2 & IEC-60364-7-710 along with insulation monitoring device& fault location system shall be provided as mentioned above. Supplier/ Vender to quote necessary hardware to fulfill the requirement. b.A complete panel consisting of all items along with indicating lamp for (Mains On, Healthy & Faulty condition), MCBs, Exhaust Fan and air filter shall be supplied. All internal wiring should terminate in connectors with screw and clampspring connections of the Klippon type mounted, on a DIN rail and labeledwith indelible proprietary labels. Individual fuses or miniature circuitbreakers should protect all internal circuits. All internal wiring should be ofthe high temperature type and enclosed in propriety ducting or mini. Allinternal wires should be marked with plastic ferrule type cable markers, forease of identification.Bender Make or Equivalent. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1318060.0 | 1318060.0 | 2.0 | False | None | None | False | None | False | 2636120.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | MGPLS | 14922586.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2957994 | 97758 | None | Code01 | OXYGEN MAIN MANIFOLD SYSTEM : 40 cylinder (20+20) Oxygen Manifold should be suitable to withstand a pressure of 140 Kg/Cm2and above along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising high pressure copper pipes of size 12mm I.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 224554.0 | 224554.0 | 1.0 | False | None | None | False | None | False | 224554.0 | 0 | 2957995 | 97758 | None | Code02 | Micro process based Automatic High flow Upto 2200 ltrs/min Oxygen Control Panel. Fully automatic changeover panel 3 SOURCE FULLY AUTOMATIC OXYGEN CONTROL PANEL Working Pressure from the oxygen concentrator plant 4.1 kg/cm2 (Future Provision). Working Pressure from fully automatic control panel. 4.1 kg/cm2. Working Pressure from Emergency manifold system 4.1 kg/cm2. Changeover unit of all 3 sources should be at the pressure from oxygen concentrator plant Below 4.1kg/cm2. Changeover unit of all 3 sources should be at the pressure from main Manifold system Below 4.1kg/cm2.Changeover unit of all 3 sources should be at the pressure from Emergency manifold system Below 4.1kg/cm2. The Control panel shall be of fully integrated type with all safety features inbuilt for high pressure and high flow Upto 2200 ltrs / min Oxygen system. All the electrical circuits should be operated at 12 volts & 24 volts with provision of inbuilt power conversion equipment. The Panel shall have the necessary instruments, gauges, LED Indicators etc. complete with separate indicators far from separate 3 sources. Pressure from oxygen concentrator plant Green signal for Normal pressure & Red signal for Low pressure. Pressure for manifold system Green signal for Normal Pressure & Red signal for low pressure.Left bank Green signal for Normal Pressure & Red for Low pressure. In Right bank Green signal for Normal Pressure & Red for Low pressure. In Emergency manifold Green signal for Normal Pressure & Red for Low pressure. Main Line Green signal for Normal Pressure & Red for Low pressure. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 217120.0 | 217120.0 | 1.0 | False | None | None | False | None | False | 217120.0 | 0 | 2957996 | 97758 | None | Code03 | OXYGEN MANIFOLD SYSTEM :EMERGENY The Control pannel shall be of fully integrated type with all saftety futures inbuilt for high pressure and high flow upto 2200 ltrs / min Oxygen system. 4+4 Cylinder Oxygen Manifold Should be suitable be withstand a pressure of 140 Kg/Cm2and above, along with high pressure copper annealed tail pipes with end Brass adapter suitable for Oxygen Cylinders and manifold. Top frame comprising of high pressure copper pipes of size 12mmI.D x 1.5mm wall thick, with high pressure brass fittings made of high tensile brass and connections through non-return values; high pressure copper tail pipes, made of high pressure copper pipe of size 7mm I.D x 1.5mm wall thick and a single state high pressure high flow regulator connected to a high pressure brass block. The design of middle and bottom frames should be provided to fit both round and flat bottom cylinders safely. The manifold should be tested (hydraulically) at 3500 psig and necessary test certificates should accompany along with the supply. SEMI AUTOMATIC EMERGENCY OXYGEN MANIFOLD CONTROL PANEL Semi automatic control panels designed for various control functions required during supply of oxygen through the manifold unit. Enclosed in a metal cabinet. This semi automatic control panel is highly efficient in triggering the signal for the Reserve system to go operational in case primary and secondary system fails in emergency. This panel is normally connected in a permanent mode and change over is semi automatic. Some of the features of this pannels are as follows Control panel shall be made of M.S.duly powder coated. Easy maintenance. Highly reliable. Designed for safety and continuity of flow supply at a constant pressure. Pressure gauge facility to indicate the gas pressure of each header and pipe line distribution pressure. Capable to provide a distribution flow rate in excess of 1500LPM.Should have Incorporation of safety features in case pressure exceeds 100Psi. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 155760.0 | 155760.0 | 1.0 | False | None | None | False | None | False | 155760.0 | 0 | 2957997 | 97758 | None | Code04 | NITROUS OXIDE MAIN MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 2 cylinder (1 + 1) Nitrous Oxide manifold supply with all necessary controls and safety fittings. Make of AKTIV or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work.
SEMI AUTOMATIC NITROUS OXIDE MAIN MANIFOLD CONTROL PANEL Supply, Installation, Testing and commissioning of 500 lpm deliver capacity manifold control panel, control panel should have all necessary controls and safety fittings. with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Nitrous Oxide System ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 88500.0 | 88500.0 | 1.0 | False | None | None | False | None | False | 88500.0 | 0 | 2957998 | 97758 | None | Code05 | NITROUS OXIDE EMERGENCY MANIFOLD SYSTEM Supply, Installation, Testing and commissioning of 1 cylinders Nitrous Oxide manifold supply with all necessary controls and safety fittings and 0 To 10 Kg/cm2 High Presuure Regulator complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 47200.0 | 47200.0 | 1.0 | False | None | None | False | None | False | 47200.0 | 0 | 2957999 | 97758 | None | Code06 | MEDICAL AND SURGICAL AIR SYSTEMCompressed Air System: System For Medical use.Type : Reciprocating, Air cooled, Oil/ Grease freeCapacity of Piston Displacement : 52.7 cfm 1620 LpmDrive : Belt drivenNo. of Air Compressors : 2 Nos. (1W + 1S by)Motor Capacity : 15 HP as requiredReceiver Capacity : 2000 liters water capacity After Reservoir shall have oil seperator and Moisture Receiver type : Automatic Vertical type with inlet, outlet & drain provisions ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 1770000.0 | 1770000.0 | 1.0 | False | None | None | False | None | False | 1770000.0 | 0 | 2958000 | 97758 | None | Code07 | Duplex Medical Air Dryer System ( Breathing Air System) (2 Nos of 1 set) 100 CFM Air Dryer Min Working Pressure should be 4 bar,Rated Inlet Pressure should be 7 bar Max Working Pressure should be 16 barSupply Voltage Should be 100-240 VAC, 50/60 Hz, 1 PhRated Inlet temperature should be 38 deg CDryer capable to give should be 40 PDPPurge Loss 15% Air quality As per NFPA 99Dual SystemThree stage filter (Dessicated drier)CO & Dew point level as per NFPA 99Bacterial Penetration 0.00001%Failure IndicationPurge Saving control ManualNo refrigerant usedEnergy saving Dew point based dryer cycling. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 | 2958001 | 97758 | None | Code08 | DUPLEX COMPRESSED AIR BREATHING FILTERATION SYSTEM-3 STAGEThe filters Shouldhave maximum contaminant removal efficiency with minimum pressure drop. The filtration system should conform to breathing air filtration as per ISO 8573 Ch I Standard. Total 3-stages of filters Shouldbe used as mentioned below:Stage 1: Oil aerosol contents removal up to 0.5 mg/cum. Stage 2: Oil aerosol contents removal up to 0.01 mg/cum.Stage 3: Oil content removal up to 0.003 mg/cum along with removal of oil vapor and hydrocarbon odor as per ISO 8573 Ch-I Standard. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 2958002 | 97758 | None | Code09 | Air Cooler : Supply, Installation, Testing and Commissioning of 80 CFM Air cooler system, with 3 phase fan (High RPM Fan) suitable for 415 V, 3Phs 50 Hz ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 2958003 | 97758 | None | Code10 | VACCUM SUPPLY SYSTEM
The pump installation shall be Duplex system consisting of 2 Nos (1W+1S BY) identical Rotary Vane Type Pumps each of which shall be capable of independently producing designed systems flow rate.
The pump shall be clearly marked with its performance, both its free air displacement and its volumetric throughput. Each pump should have capacity of minimum 4928LPM (300m3/h) i.e., 176 CFM. Pump should be capable of providing a vacuum of not less than 650 mm Hg (87 kPa).
The driving motor shall directly drive the pump unit and it shall be manufactured in accordance with HTM 2022/HTM 02-01 / conforms to IEC Standards. Recommendations suitable for 415 voltes, 3 phase, 50 Hz power supply.Each pump shall have a built in non-return valve and pressure switch such that inadvertent reversal of the motor Should not pressurize the Reservoir or the distribution system protection.The control panel shall consist of three separate , The system should include vacuum storage reservoir tank, Rated for full vacuum services with the storage capacity of approx 3000Ltr as per standard recommendation. It should be equipped with an vacuum gauge and provision for manual draining by pass valve. The inside of the tank should be coated with a two-component coating to provide a hard, durable lining for rust Compartments, two compartments shall hold the motor starters, MCBS ammeters, and hours run-meters, for each pump. The remaining compartment shall house the vacuum switches, status monitoring equipment, delay timer and necessary interlock, selector switch with automatic change over, etc., complete with internal wiring using copper conductors. Control Panel system should be front operable. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 1593000.0 | 1593000.0 | 1.0 | False | None | None | False | None | False | 1593000.0 | 0 | 2958004 | 97758 | None | Code11 | VACUUM BACTERIAL FILTERATION,
Suitable Medical Vacuum filters are used for removal of bacteria & other contamination from the suction side of vacuum pumps, preventing infection of pump and the atmosphere.
These elements shall be of pleated construction giving a high surface area and long operational life. The efficiency to exceed the 0.005% penetration specified in HTM2022 for infectious disease unit.- i.e. complete bacterial removal. Elements shall be fitted in an aluminum housing suitable for various capacities. These are to be internally protected against corrosion by an alocrom treatment. The inner & outer surfaces of the housing are epoxy coated. Complete assembly shall be fitted with a sterilisable drain flask with isolation valve for removal of liquid if any. Differential pressure indicators are to be provided to monitor the status of element. Basics Specifications are as given below. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 165200.0 | 165200.0 | 1.0 | False | None | None | False | None | False | 165200.0 | 0 | 2958005 | 97758 | None | Code12 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 54mm. ODx1.2 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 4854.52 | 4854.52 | 80.0 | False | None | None | False | None | False | 388361.6 | 0 | 2958006 | 97758 | None | Code13 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 42mm. ODx1.2 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 3608.44 | 3608.44 | 220.0 | False | None | None | False | None | False | 793856.8 | 0 | 2958007 | 97758 | None | Code14 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 35mm. ODx1.2 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2570.04 | 2570.04 | 160.0 | False | None | None | False | None | False | 411206.4 | 0 | 2958008 | 97758 | None | Code15 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 28mm. ODx0.9 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1492.7 | 1492.7 | 430.0 | False | None | None | False | None | False | 641861.0 | 0 | 2958009 | 97758 | None | Code16 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 22mm. ODx0.9 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1156.4 | 1156.4 | 1030.0 | False | None | None | False | None | False | 1191092.0 | 0 | 2958010 | 97758 | None | Code17 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 15mm. ODx0.9 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 949.9 | 949.9 | 1550.0 | False | None | None | False | None | False | 1472345.0 | 0 | 2958011 | 97758 | None | Code18 | PIPELINE DISTRIBUTION SYSTEM
Supply, Installation, Testing and commissioning of copper pipe for medical gas services. Pipes shall be priced for all necessary supports, standard fittings. Make of MEX FLOW or Equilaent Make complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. Copper Pipe 12mm. ODx0.7 mm.thick. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 651.36 | 651.36 | 620.0 | False | None | None | False | None | False | 403843.2 | 0 | 2958012 | 97758 | None | Code19 | OUTLET POINTS - Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Oxygen Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3392.5 | 3392.5 | 166.0 | False | None | None | False | None | False | 563155.0 | 0 | 2958013 | 97758 | None | Code20 | OUTLET POINTS - Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Vacuum Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3392.5 | 3392.5 | 110.0 | False | None | None | False | None | False | 373175.0 | 0 | 2958014 | 97758 | None | Code21 | OUTLET POINTS - Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Compressed Air Outlets 4 Bar - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3392.5 | 3392.5 | 110.0 | False | None | None | False | None | False | 373175.0 | 0 | 2958015 | 97758 | None | Code22 | OUTLET POINTS - Should have terminated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes)
Compressed Air Outlets 7 Bar- drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3392.5 | 3392.5 | 4.0 | False | None | None | False | None | False | 13570.0 | 0 | 2958016 | 97758 | None | Code23 | Nitrous Oxide Outlets - drops of 10 mm dia copper pipe terminated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3392.5 | 3392.5 | 4.0 | False | None | None | False | None | False | 13570.0 | 0 | 2958017 | 97758 | None | Code24 | Oxygen Flow meter with Humidifier Bottle: Flow meter should be Backpressure Compensated. Flow meter should be accurate gas flow measurement and control within a range of 0-15 liters per minute. It should meet strict precision and durabiliy standards. Flow meter body should be made of brass material Flow tube and shroud components should be made of clear, impact resistant polycarbonate. The humidifier bottle should be unbreakable polycarbonate material and autoclavable at 134 degrees centigrade.The humidifier should have built in safety valve.With Calibration Certificates. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2849.7 | 2849.7 | 122.0 | False | None | None | False | None | False | 347663.4 | 0 | 2958018 | 97758 | None | Code25 | Single piece wall mounted suction collection & regulation unit. With jar capacity of 600ml each shall be provided at each of the bed side. Jars are should be made of autoclavable materials. The units shall be clamped to the wall using suitable clamps. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3528.2 | 3528.2 | 106.0 | False | None | None | False | None | False | 373989.2 | 0 | 2958019 | 97758 | None | Code26 | Theatre Vacuum Unit: The unit should comprise of two reusable 2000 ml shatter resistant bottle, each made up of poly carbonate material and fully auto cleavable at 134 degree centigrade. Should have a vacuum regulator with instant ON / OFF switch a three way selector switch with an option to operate either.- Left, Right or BothAll the above items Should be mounted on a Trolley having a free moving castor wheels. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 14750.0 | 14750.0 | 2.0 | False | None | None | False | None | False | 29500.0 | 0 | 2958020 | 97758 | None | Code27 | ISOLATION VALVE : Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction -Isolation Valves 54 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 8826.4 | 8826.4 | 3.0 | False | None | None | False | None | False | 26479.2 | 0 | 2958021 | 97758 | None | Code28 | ISOLATION VALVE : Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction - Isolation Valves 42 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 8142.0 | 8142.0 | 6.0 | False | None | None | False | None | False | 48852.0 | 0 | 2958022 | 97758 | None | Code29 | ISOLATION VALVE : Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction - Isolation Valves 35 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 5428.0 | 5428.0 | 11.0 | False | None | None | False | None | False | 59708.0 | 0 | 2958023 | 97758 | None | Code30 | ISOLATION VALVE : Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction - Isolation Valves 28 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4071.0 | 4071.0 | 8.0 | False | None | None | False | None | False | 32568.0 | 0 | 2958024 | 97758 | None | Code31 | ISOLATION VALVE : Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction - Isolation Valves 22 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3392.5 | 3392.5 | 28.0 | False | None | None | False | None | False | 94990.0 | 0 | 2958025 | 97758 | None | Code32 | ISOLATION VALVE : Should be 900 turn, ball valves of brass body, duly chrome plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy maintenance. ID of the copper pipe and the ball valve should have same dimensions to avoid the flow friction Isolation Valves 15 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2714.0 | 2714.0 | 79.0 | False | None | None | False | None | False | 214406.0 | 0 | 2958026 | 97758 | None | Code33 | Zonal Valve box five Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 23364.0 | 23364.0 | 2.0 | False | None | None | False | None | False | 46728.0 | 0 | 2958027 | 97758 | None | Code34 | Zonal Valve box three Gas services An Zonal area valve box should have bellow spec. Wall mounted M.S. box with powder coated & lockable, Front glass mounting easily visible & using imported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 18319.5 | 18319.5 | 4.0 | False | None | None | False | None | False | 73278.0 | 0 | 2958028 | 97758 | None | Code35 | Digital Area Alarm for five Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 41300.0 | 41300.0 | 2.0 | False | None | None | False | None | False | 82600.0 | 0 | 2958029 | 97758 | None | Code36 | Digital Area Alarm for Three Gas Systems.
Micro processor controlled Area Gas alarm panel five Lines, Should audio- visual alarms for each gas used on the floor and come fitted with test and mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, medium & high pressure sensors. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 34220.0 | 34220.0 | 4.0 | False | None | None | False | None | False | 136880.0 | 0 | 2958030 | 97758 | None | Code37 | Bed Headed Panel and Railing. 1.5meter
Double railing Bed headed panels should have below Specifications.
Accessories 1. IV Stand extendable type with aluminium slider. 2. Monitor stand wall panel mounted. 3. Ward vaccum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 Amp 6 nos of 6 amps sockets with control switches Electrical Sockets.
Provision Medical Gas Terminal Units as follows. 2.1 Two oxygen outlet.
2.2 One Vacuum outlet. 2.3 One compressed Air outlet 4 Bar. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 31860.0 | 31860.0 | 40.0 | False | None | None | False | None | False | 1274400.0 | 0 | 2958031 | 97758 | None | Code38 | Surgeon Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation:340n.w.:158kg.Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 230100.0 | 230100.0 | 2.0 | False | None | None | False | None | False | 460200.0 | 0 | 2958032 | 97758 | None | Code39 | Anaesthesia Single Arm Pendant: The material of the Pendent should be Single-armed rotary ceiling mounted surgical Pendent High-strength aluminum alloy. Extension arm 700mm.Loading capacity: 70-150kg.Level degrees rotation:340n.w.:158kg.Should be provision for Gas outlets Oxygen 02 nos, Vaccum 01 nos,Air 4 Bar 01 nos,Air 7 Bar 01 nos, Nitrous Oxide01 nos,Power socket 08 nos,Grounding terminal 01 nos,Platform 03 nos, IV pole 01 nos,Drawer 01 nos. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 230100.0 | 230100.0 | 2.0 | False | None | None | False | None | False | 460200.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Fire Fighting works | 24602612.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958033 | 97759 | None | Code01 | Supply, erection, testing & commissioning of electrical motor driven end suction back pull out centrifugal pump capable of delivering, adequate LPM at required head. when running at 2900 rpm directly coupled to TEFC electrical motor of adequate HP to operate on 400/440V 3phase, 50cycles AC supply with required foundation for pump, a terminal box suitable for reception, common bed plate with necessary antivibration pads, necessary foundation bolts and accessories, neoprine gaskets (16kg/sq.cm) Control panel is excluded. Required GA drawing for the pump/foundation shall be submitted by the contractor. 2280 lpm@70 m head ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 369930.0 | 369930.0 | 1.0 | False | None | None | False | None | False | 369930.0 | 0 | 2958034 | 97759 | None | Code02 | Supply, installation, testing & commissioning of diesel engine driven pump, horizontal mounted, Horizontal spilt case centrifugal single stage pump, capable of delivering required flow at required head when running at 1800 RPM with adequate BHP automatic diesel engine driven pump set having the residential silencer system and other accessories like fueltank, ecessary radiator cooling system, flanges, neoprene gaskets (16.0kg/sqcm), 200 litres fuel storage tank with piping, valves as per detailed specification and two separate starting mechanisms (automatic starting by battery power, electric starting motor as well as manual starting by electric start motor) common bed plate with anti vibration pads, necessary foundation, foundation bolts etc - 2280 lpm@70 m head ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 721688.0 | 721688.0 | 1.0 | False | None | None | False | None | False | 721688.0 | 0 | 2958035 | 97759 | None | Code03 | Supply, Installation, testing and commisioning electrically driven jockey pump of capacity 180.0Lpm at required head end suction type bronze impeller pump coupled to electrical driven motor with suitable HP with all the necessary accessories, operating on 3Ph 50Hz, 400/440V AC supply including foundation, foundation bolts, antivibration pad, etc. complete. Including cost of materials, labour, usage charges of machinery complete as pers pecifications. Control panle is excluded. Required GA drawing for the pump/ foundation shall be submitted by the contractor-180 lpm@70 m head ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 110330.0 | 110330.0 | 1.0 | False | None | None | False | None | False | 110330.0 | 0 | 2958036 | 97759 | None | Code04 | Supplying Installing testing and commissiong COMMON Control panel for fire fighting system consiting of electrical motor driven 60HP Main fire pump, Diesel engine driven pump 60 BHP & Jockey pump 7.5HPSupply, erection, testing and commissioning of Fire Fighting panel cubicle type made out of 14/16Swg MS CRCA sheet which is derusted, degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel tobe dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and out going feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners. The switch boards are tobe tested as per IS 8623-1977 specifications. Bus bars are tobe of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.Incoming feeder for 250A TPN MCCB with 250Amps. TPN Al. Busbars with color coded heat shrinkable PVC sleeves, RYB indicating lamps with individual MCB control. Suitable Mulit Fuction meter with CTsOUTGOINGFeeder for 1No.of main pump:-1 Nos. 160A TP MCCB with 60 HP Star delta starter with overload relay, single phase preventer and indicating lamps with ON / OFF push buttons. 1 No. Automanual selector switch. Feeder for 1 No. of Jockey pump:-1 No. 63A TP MCCB with 7.5HP star delta starter with overload relay, single phase preventer and indicating lamp swith ON / OFF push buttons. 1 No. Automanual selector switch. Feeder for 1 No. DIESEL ENGINE MAIN PUMP:- a) 20Amps DP MCB-4Nos. b) Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, T Trickle / booster off selector switch- 2 Nos. c) 1 set of indicating lamps for the following: 1. phase indication 2. battery charger on 3. overload relay 4. DC supply on 5. control switch on 6. Engine fails to start 7. Pump on 8. Low oil pressure 9. High water temperature 10. Automanual selector switch d) 1 sets of push button stations for the following: 1. Engine Start 2. EngineStop 3. Engine-hooter ACK 4. Engine-fault resete) Selector switches (Engine control, mode selector)-1 No. f) Auxiliary relays / contactors / timer for sequence operating for starting and stopping of the engine-1 set .g) Hooter for audio alarm (Industrial type) - 1 No. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Unit | 360844.0 | 360844.0 | 1.0 | False | None | None | False | None | False | 360844.0 | 0 | 2958037 | 97759 | None | Code05 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 200 mm dia CI Butterfly valaves ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 20768.0 | 20768.0 | 4.0 | False | None | None | False | None | False | 83072.0 | 0 | 2958038 | 97759 | None | Code06 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work -150 mm dia CI Butterfly valaves ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 16225.0 | 16225.0 | 6.0 | False | None | None | False | None | False | 97350.0 | 0 | 2958039 | 97759 | None | Code07 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 100 mm dia CI Butterfly valaves ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11682.0 | 11682.0 | 4.0 | False | None | None | False | None | False | 46728.0 | 0 | 2958040 | 97759 | None | Code08 | Supplying, installing, testing and commissioning of PN 16 CI butterfly valves of confirming to IS 13039 with necessary nuts & bolts etc., complete etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 80 mm dia CI Butterfly valaves ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9086.0 | 9086.0 | 1.0 | False | None | None | False | None | False | 9086.0 | 0 | 2958041 | 97759 | None | Code09 | Supplying installing, testing and commissioning of PN 16 CI "Non Return Valve "confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 200 mm Dia CI Non return valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 18172.0 | 18172.0 | 1.0 | False | None | None | False | None | False | 18172.0 | 0 | 2958042 | 97759 | None | Code10 | Supplying installing, testing and commissioning of PN 16 CI "Non Return Valve "confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 150 mm Dia CI Non return valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 16225.0 | 16225.0 | 4.0 | False | None | None | False | None | False | 64900.0 | 0 | 2958043 | 97759 | None | Code11 | Supplying installing, testing and commissioning of PN 16 CI "Non Return Valve "confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work -100 mm Dia CI Non return valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9241.76 | 9241.76 | 4.0 | False | None | None | False | None | False | 36967.04 | 0 | 2958044 | 97759 | None | Code12 | Supplying installing, testing and commissioning of PN 16 CI "Non Return Valve "confirming to IS 13039 with necessary bolts and nuts etc,. complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete. etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work - 80 mm Dia CI Non return valve ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 7139.0 | 7139.0 | 2.0 | False | None | None | False | None | False | 14278.0 | 0 | 2958045 | 97759 | None | Code13 | supply and installing testing and commissioning of CI "Y" stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete.- complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-200 mm Dia CI "Y" Stariner ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 31801.0 | 31801.0 | 2.0 | False | None | None | False | None | False | 63602.0 | 0 | 2958046 | 97759 | None | Code14 | supply and installing testing and commissioning of CI "Y" stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete.- complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-150 mm Dia CI "Y" Stariner ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 24077.9 | 24077.9 | 2.0 | False | None | None | False | None | False | 48155.8 | 0 | 2958047 | 97759 | None | Code15 | supply and installing testing and commissioning of CI "Y" stainer confirming to IS standard with necessary bolts and nuts complete includes cost of all materials labour charges with all lead lift loading and unloading transportation etc complete.- complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work-100 mm Dia CI "Y" Stariner ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 16082.22 | 16082.22 | 2.0 | False | None | None | False | None | False | 32164.44 | 0 | 2958048 | 97759 | None | Code16 | Pressure Switch including Isolation Valve and forged siphon Tube including with all accssories as per IS :Spec.etc.,complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2531.1 | 2531.1 | 6.0 | False | None | None | False | None | False | 15186.6 | 0 | 2958049 | 97759 | None | Code17 | Supplying and fixing air vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain
arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade
as required. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 38940.0 | 38940.0 | 1.0 | False | None | None | False | None | False | 38940.0 | 0 | 2958050 | 97759 | None | Code18 | Pressure guage of 150mm dia including Isolation Valve and forged siphonTube including with all accssories as per IS :Spec.etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 3764.2 | 3764.2 | 3.0 | False | None | None | False | None | False | 11292.6 | 0 | 2958051 | 97759 | None | Code19 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 190.81 | 190.81 | 1200.0 | False | None | None | False | None | False | 228972.0 | 0 | 2958052 | 97759 | None | Code20 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.-3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 667223.92 | 667223.92 | 0.08 | False | None | None | False | None | False | 53377.9136 | 0 | 2958053 | 97759 | None | Code21 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.-3.5 Core 95.00 Sq.mm.Main Panel Electrical Pump ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 667223.92 | 667223.92 | 0.1 | False | None | None | False | None | False | 66722.392 | 0 | 2958054 | 97759 | None | Code22 | FIREFIGHTING ELECTRICALSupply of the Following XLPE armoured cable 1100 V Grade with ISI mark stranded / solid, aluminimum conductor complete with crimping type Lugs and Glands etc completed.-4.0 Core 16.00 Sq.mm.Main Panel to Jockey ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 238107.72 | 238107.72 | 0.2 | False | None | None | False | None | False | 47621.544 | 0 | 2958055 | 97759 | None | Code23 | 12 Core x 2.5Sqmm For Main Panel to DG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 684.4 | 684.4 | 50.0 | False | None | None | False | None | False | 34220.0 | 0 | 2958056 | 97759 | None | Code24 | 3 Core x 1.5Sqmm for Pressure Switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 123.31 | 123.31 | 70.0 | False | None | None | False | None | False | 8631.7 | 0 | 2958057 | 97759 | None | Code25 | Supplying, installation, testing & commissioning of 12V ..AH batteries in poly propylene container for D.G. sets. Low maintenance batteries, plate type. (150 AH capacity) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 36586.73 | 36586.73 | 1.0 | False | None | None | False | None | False | 36586.73 | 0 | 2958058 | 97759 | None | Code26 | Supplying and installing following size of perforated painted with powder cating m.s. cable trays with perforation not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with m.s. suspenders including bolts & nuts, painting suspendrrs etc as required. Size: 300mm width x50mm depth x1.6mm thickness ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1008.55 | 1008.55 | 100.0 | False | None | None | False | None | False | 100855.0 | 0 | 2958059 | 97759 | None | Code27 | GI/Copper strips for grounding connections, using necessary fixing
materials as required. (25 x 3 mm GI strip) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 106.44 | 106.44 | 125.0 | False | None | None | False | None | False | 13305.0 | 0 | 2958060 | 97759 | None | Code28 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-200 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 5581.4 | 5581.4 | 35.0 | False | None | None | False | None | False | 195349.0 | 0 | 2958061 | 97759 | None | Code29 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-150 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 5062.2 | 5062.2 | 700.0 | False | None | None | False | None | False | 3543540.0 | 0 | 2958062 | 97759 | None | Code30 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-100 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 3699.3 | 3699.3 | 650.0 | False | None | None | False | None | False | 2404545.0 | 0 | 2958063 | 97759 | None | Code31 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-80 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 2985.4 | 2985.4 | 450.0 | False | None | None | False | None | False | 1343430.0 | 0 | 2958064 | 97759 | None | Code32 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-65 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 2206.6 | 2206.6 | 380.0 | False | None | None | False | None | False | 838508.0 | 0 | 2958065 | 97759 | None | Code33 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-50 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1687.4 | 1687.4 | 500.0 | False | None | None | False | None | False | 843700.0 | 0 | 2958066 | 97759 | None | Code34 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-40 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1362.9 | 1362.9 | 600.0 | False | None | None | False | None | False | 817740.0 | 0 | 2958067 | 97759 | None | Code35 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-32 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1038.4 | 1038.4 | 450.0 | False | None | None | False | None | False | 467280.0 | 0 | 2958068 | 97759 | None | Code36 | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions,Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc.-25 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 908.6 | 908.6 | 2650.0 | False | None | None | False | None | False | 2407790.0 | 0 | 2958069 | 97759 | None | Code37 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 150 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 519.2 | 519.2 | 700.0 | False | None | None | False | None | False | 363440.0 | 0 | 2958070 | 97759 | None | Code38 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 100 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 324.5 | 324.5 | 300.0 | False | None | None | False | None | False | 97350.0 | 0 | 2958071 | 97759 | None | Code39 | Wraping and Galing of U/G pipe line work includes one coat of anti corrossion paint (Black) and two coats of Bituminous cloth. including cost of materials, labour, usage charges of machinery complete as per specifications. - 80 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 259.6 | 259.6 | 200.0 | False | None | None | False | None | False | 51920.0 | 0 | 2958072 | 97759 | None | Code40 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 100mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11682.0 | 11682.0 | 18.0 | False | None | None | False | None | False | 210276.0 | 0 | 2958073 | 97759 | None | Code41 | Supplying, installing , testing and commissioning approved make CI butterfly valves of 50mm diameter confirming to IS 13039 with necessary nuts & bolts etc., complete ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 5841.0 | 5841.0 | 10.0 | False | None | None | False | None | False | 58410.0 | 0 | 2958074 | 97759 | None | Code42 | Providing & fixing Flow Switch in following sizes M.S. pipe including connnection etc as required.100mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9753.17 | 9753.17 | 8.0 | False | None | None | False | None | False | 78025.36 | 0 | 2958075 | 97759 | None | Code43 | Supplying Installing, testing and commissioning of hydraulically operated sprinkler Gong Valve with water meter gong bell and trims as required, pressure gauges drain Valve, ball Valves check valve, strainer etc. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 90860.0 | 90860.0 | 1.0 | False | None | None | False | None | False | 90860.0 | 0 | 2958076 | 97759 | None | Code44 | Supplying Installing, testing and commissioning of 150mm dia 4way Fire brigade inlet connection with Non retrn valve of 4nos. 63mm dia. Including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 49324.0 | 49324.0 | 1.0 | False | None | None | False | None | False | 49324.0 | 0 | 2958077 | 97759 | None | Code45 | Supplying Installing, testing and commissioning of 100mm dia 2 way Fire
brigade inlet connection of 2 nos. 63 mm dia. including cost of materials,
labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 42834.0 | 42834.0 | 1.0 | False | None | None | False | None | False | 42834.0 | 0 | 2958078 | 97759 | None | Code46 | Stainless steel braide flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16bar pressure rating and 1500mm long 25mm dia with union / reducer collar, clamps etc. as required. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 3245.0 | 3245.0 | 100.0 | False | None | None | False | None | False | 324500.0 | 0 | 2958079 | 97759 | None | Code47 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 142.78 | 142.78 | 100.0 | False | None | None | False | None | False | 14278.0 | 0 | 2958080 | 97759 | None | Code48 | INTERNAL FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning of 63mm dia Single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 13629.0 | 13629.0 | 9.0 | False | None | None | False | None | False | 122661.0 | 0 | 2958081 | 97759 | None | Code49 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined 2nos .RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6490.0 | 6490.0 | 18.0 | False | None | None | False | None | False | 116820.0 | 0 | 2958082 | 97759 | None | Code50 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5841.0 | 5841.0 | 9.0 | False | None | None | False | None | False | 52569.0 | 0 | 2958083 | 97759 | None | Code51 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with lacing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size
20"x24"x10" complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 8437.0 | 8437.0 | 9.0 | False | None | None | False | None | False | 75933.0 | 0 | 2958084 | 97759 | None | Code52 | Supplying Installing, testing and commissioning of Hose reel cabin ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6619.8 | 6619.8 | 9.0 | False | None | None | False | None | False | 59578.2 | 0 | 2958085 | 97759 | None | Code53 | Supplying Installing, of M.S. Pressed reel of 600mm dia swinging type motion which allows a 180 swing and conforms to IS:884/85 or Aluminium fitting Single Piece Compact Type. including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6749.6 | 6749.6 | 9.0 | False | None | None | False | None | False | 60746.4 | 0 | 2958086 | 97759 | None | Code54 | Supplying Installing, testing and commissioning of 19mm dia 40.0m length hose with rubber lining smooth bore, reinforced of natural/synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf/sqcm confirms & tested as per IS 444/ IS 12585 including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7788.0 | 7788.0 | 9.0 | False | None | None | False | None | False | 70092.0 | 0 | 2958087 | 97759 | None | Code55 | Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1947.0 | 1947.0 | 4.0 | False | None | None | False | None | False | 7788.0 | 0 | 2958088 | 97759 | None | Code56 | SITC of Gun metal BALL VALVE SIZE OF 25mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1557.6 | 1557.6 | 8.0 | False | None | None | False | None | False | 12460.8 | 0 | 2958089 | 97759 | None | Code57 | SITC of Gun metal BALL VALVE SIZE OF 20mm dia ---- etc., complete as per specificaiton with all lead and lift, loading unloading, labour, hire charges of machineries and all such incidental charges necessary for successful completion of work and as per directions of the Engineer-in-charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1233.1 | 1233.1 | 8.0 | False | None | None | False | None | False | 9864.8 | 0 | 2958090 | 97759 | None | Code58 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 406.27 | 406.27 | 25.0 | False | None | None | False | None | False | 10156.75 | 0 | 2958091 | 97759 | None | Code59 | Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent/upwrite type standard response standard coverage, sprinkler, ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 486.75 | 486.75 | 895.0 | False | None | None | False | None | False | 435641.25 | 0 | 2958092 | 97759 | None | Code60 | Supplying, installing of horizontal side wall type, standard response, standard coverage, sprinkler,K 5.6 (80), 1/2 " NPT, 68 Degree C, Crome finish UL listed. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 454.3 | 454.3 | 50.0 | False | None | None | False | None | False | 22715.0 | 0 | 2958093 | 97759 | None | Code61 | Supplying, installing of concealed type , standard response, standard coverage, sprinkler,K 5.6 (80), 1/2 " NPT, 68 Degree C, Crome finish UL listed. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1038.4 | 1038.4 | 20.0 | False | None | None | False | None | False | 20768.0 | 0 | 2958094 | 97759 | None | Code62 | Supplying Installing, testing and commissioning of Ceiling Mounted powder coated Surface Finishing Mild Steel Rosette Plate including cost of materials, labour, usage charges of machinery complete as per specifications ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 142.78 | 142.78 | 100.0 | False | None | None | False | None | False | 14278.0 | 0 | 2958095 | 97759 | None | Code63 | Stainless steel braided flexible pipe (hose) for dropping sprinklers below false ceiling, pipe shall be 16 bar pressure rating and 1500 mm long 25 mm dia with union / reducer collar, clamps etc. as required. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3245.0 | 3245.0 | 100.0 | False | None | None | False | None | False | 324500.0 | 0 | 2958096 | 97759 | None | Code64 | Supply, erection, testing and commissioning of 1" GI/MS collar. ---- etc.,complete with all leads And lifts as per specifications and as directed by the Engineer-in-charge . ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 142.78 | 142.78 | 1035.0 | False | None | None | False | None | False | 147777.3 | 0 | 2958097 | 97759 | None | Code65 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 190.81 | 190.81 | 2250.0 | False | None | None | False | None | False | 429322.5 | 0 | 2958098 | 97759 | None | Code66 | Supplying Installing, testing and commissioning of 63mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve,spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 13629.0 | 13629.0 | 8.0 | False | None | None | False | None | False | 109032.0 | 0 | 2958099 | 97759 | None | Code67 | Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female lnstantainious Gun metal coupling as per IS 903 complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6490.0 | 6490.0 | 16.0 | False | None | None | False | None | False | 103840.0 | 0 | 2958100 | 97759 | None | Code68 | Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 complete including cost of materials, labour,usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5841.0 | 5841.0 | 8.0 | False | None | None | False | None | False | 46728.0 | 0 | 2958101 | 97759 | None | Code69 | Supplying Installing, testing and commissioning of Hose cabinet made out of 18
gauge M.S.sheet with double glass door with lacing arrangement and painted with
two coats of Fire red Enamel paint at outer ise of the Box and two coats of white
enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size
20"x24"x10" complete including cost of materials, labour, usage charges of
machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 8437.0 | 8437.0 | 8.0 | False | None | None | False | None | False | 67496.0 | 0 | 2958102 | 97759 | None | Code70 | CO2 2Kg Squeeze grip
Providing 2 Kg C02 Gas Type Fire Extinugisher Squeeze grip type, used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time less than 8 Sees, Controllable discharge
mechanism, Applicable on Class 8&C Fire, 8 Rating 88, Can Construction : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness: 4.0MM lSI Approved, 1 Year Warranty.with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5321.8 | 5321.8 | 30.0 | False | None | None | False | None | False | 159654.0 | 0 | 2958103 | 97759 | None | Code71 | C02 4.5Kg Squeeze grip:-Providing 4.5Kg CO2 Gas Type Fire Extinugisher, Trolley Mounted, 2 Easy Weight Management used Unused Mechanism, Squeeze Grip, Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter 140MM, Discharge Time less than13 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating138, Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Sheet metal thickness : 4.5M M lSI Approved 1Year Warranty. with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications.complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9735.0 | 9735.0 | 26.0 | False | None | None | False | None | False | 253110.0 | 0 | 2958104 | 97759 | None | Code72 | Providing Aqueous Film-Forming Foam - 9 Ltr
Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.1Okg. empty weight 6.10kg Can Height 615 MM, Diameter 175 MM, Discharge Time less than 60 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6
Meters, applicable on Class A,8,CARating 13A, 8 Rating 558, Can Construction;Deep drawn & CO, Mig welded, Valve Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy PoIyster
Powder coating, Sheet metal thickness: 2.0MM, lSI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 10513.8 | 10513.8 | 6.0 | False | None | None | False | None | False | 63082.8 | 0 | 2958105 | 97759 | None | Code73 | Providing ABC Powder based MAP 50, 6Kg:-Providing 6kg Fire Extinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, usage charges of machinery complete as per specifications. complete. IS 15683 Approved, CE Marked ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3699.3 | 3699.3 | 20.0 | False | None | None | False | None | False | 73986.0 | 0 | 2958106 | 97759 | None | Code74 | Supplying of two bucket stand along with buckets. Complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1427.8 | 1427.8 | 10.0 | False | None | None | False | None | False | 14278.0 | 0 | 2958107 | 97759 | None | Code75 | Providing and fixing 6 lts water Mist, stored pressure type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9994.6 | 9994.6 | 12.0 | False | None | None | False | None | False | 119935.2 | 0 | 2958108 | 97759 | None | Code76 | Providing and fixing 3 lts water Mist, stored pressure type fire extinguishers consisting of welded MS cylindrical body, squeeze lever discharge valve fitted with pressure indicating gauge internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, conforming to ISI finished externally with red enamel paint and fixed to wall with brackets complete with internal charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9215.8 | 9215.8 | 12.0 | False | None | None | False | None | False | 110589.6 | 0 | 2958109 | 97759 | None | Code77 | Supplying of two bucket stand alongwith buckets. complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1427.8 | 1427.8 | 10.0 | False | None | None | False | None | False | 14278.0 | 0 | 2958110 | 97759 | None | Code78 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Signage with the following text "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" Size:-25cm x 30 cm) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 2.6 | 2.6 | 6750.0 | False | None | None | False | None | False | 17550.0 | 0 | 2958111 | 97759 | None | Code79 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(Floor identification signage ( ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 2.6 | 2.6 | 6750.0 | False | None | None | False | None | False | 17550.0 | 0 | 2958112 | 97759 | None | Code80 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(signage with text FIRE EXIT,Size shall be 15cm x 60cm.) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 2.6 | 2.6 | 8100.0 | False | None | None | False | None | False | 21060.0 | 0 | 2958113 | 97759 | None | Code81 | Providing and fixing in position the signages "FIRE ORDER" it should contain the following text on 3mm thick "Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of size 3' x 4'.A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS.C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, LIE DOWN FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3245.0 | 3245.0 | 12.0 | False | None | None | False | None | False | 38940.0 | 0 | 2958114 | 97759 | None | Code82 | ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM OR FIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM.B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: (Current phone numbers to be provided in this location by the contractor)C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE.D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE.E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER: (Current phone numbers to be provided in this location by the contractor)F) FIRE FIGHTING AGENCY: PHONE : (Current phone numbers to be provided in this location by the contractor)FAX : (Current fax numbers to be provided in this location by the contractor) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3245.0 | 3245.0 | 12.0 | False | None | None | False | None | False | 38940.0 | 0 | 2958115 | 97759 | None | Code83 | Providing's Escape Singage Photoluminescent rigid plastic, 2 mm thickness, Printed on High Quality glass paint with UV resistance, 5 years warranty, Material Used - Non Radiocactive, non-phosphorous, non toxic and lead free. Available in different types & sizes, Time after removing the light source (in minutes) 60 minutes, Luminescent intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay* (In Minutes) :3100, including cost of materials, labour, usage charges of machinery complete as per specifications.(route plan Fire Escape Route Plan A2 Size) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2.6 | 2.6 | 9000.0 | False | None | None | False | None | False | 23400.0 | 0 | 2958116 | 97759 | None | Code84 | Supply installation testing commissioning of P.A System Rack made out of 18 gauge M.S. Sheet with glass door with locking arrangement and powder coating grey paint two coats at inner and outer of box, is to accomodated 1 No. 250 watt amplifire, 1 No. 40 zone console and 1 no Mike and in built electronic connections circuits.Size or Rack: 0.50 m hight x 0.40 m width x 0.40 m depth ---- including all lead and lift charges loading and unloading charges labour charges, curing, cost& conveyance of all materials, transportation charges, all incidental charges, hire charges of all machinery and equipment required for successful completion of work etc., complete. The work shall be executed as per standard technical specification and directions of Engineer in charge of the work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 64251.0 | 64251.0 | 1.0 | False | None | None | False | None | False | 64251.0 | 0 | 2958117 | 97759 | None | Code85 | Supplying Installing, testing and commissioning of P.A.System console panel with push button with speaker and indictoron Accomdated in M.S.Cabinet with painting -do- 20 Zone cansole. Complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 54516.0 | 54516.0 | 1.0 | False | None | None | False | None | False | 54516.0 | 0 | 2958118 | 97759 | None | Code86 | P.A.System amplifier 250W RMS out put with complete wiring and controls accessable form front ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 45754.5 | 45754.5 | 1.0 | False | None | None | False | None | False | 45754.5 | 0 | 2958119 | 97759 | None | Code87 | Supplying Installing, testing and commissioning of MIKE ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7139.0 | 7139.0 | 1.0 | False | None | None | False | None | False | 7139.0 | 0 | 2958120 | 97759 | None | Code88 | Supplying Installing, testing and commissioning of Public address system (Two way comminication type) as per requirement of Fire Force authority and which Generally comprise of Supplying Installing, testing and commissioning of Approved make 5W.wall mounted speaker with talk back facility with store enamel painted M.S.Sheet hosing etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3180.1 | 3180.1 | 12.0 | False | None | None | False | None | False | 38161.2 | 0 | 2958121 | 97759 | None | Code89 | Supply & Laying of 2 X 1.5 Sqmm fire alarm armored cable,600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 224.55 | 224.55 | 2250.0 | False | None | None | False | None | False | 505237.5 | 0 | 2958122 | 97759 | None | Code90 | 4 Loop Panel - Supply, install, test and commissioning of addressable peer to peer Networkable analogue addressable type fire alarm control panel with minimum 1500 Character /240X64 Pixel / 7inch Touchscreen graphic LCD display. The panel should be equipped with sufficient numbers of loop with 20% spare capacity, with each networkable intelligent fire alarm Control Panel having SLC with capacity of min 126/240 detectors/ devices in any combination with key pad, dual flash-based microprocessor technology, inbuilt USB Port for upload and down load the configuration tools, RS232 serial port for direct PC or modem connection, inbuilt NAC's, min 20 programmable Zonal LEDs and operates on 240V AC + 10% with 50Hz with built in charger. The panel shall have fire, fault relays, option of BMS
integration MODBUS/ BACKNET, graphical software for provision of TCP/ IP modules, Remote Access, Class 'X' wiring with provision of both class 'A' and class 'B' wiring in the SLC circuit, user friendly with communication facility to monitor & control the FACPs from a single window. The panel shall be suitable for minimum of 5000 event record facility, event fetch from FACP facility and the single panel shall be suitable for min 2000 fire zones and 200 Panels/ Nodes in one network with all other accessories required to successfully run the system. (The System cost shall be included of all necessary cards, modules, Panel enclosure, CPU and associated accessories to complete the system design). Approval: VDS/UL/EN-54 Std. - 4 Loop Panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 324500.0 | 324500.0 | 1.0 | False | None | None | False | None | False | 324500.0 | 0 | 2958123 | 97759 | None | Code91 | Supply, intallation, testing and Commissioning of Graphical software for entire fire alarm panels including detector configuration, commissioning etc ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 356950.0 | 356950.0 | 1.0 | False | None | None | False | None | False | 356950.0 | 0 | 2958124 | 97759 | None | Code92 | Supply, intallation, testing and Commissioning of Network card for fire alram panels integration ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 97350.0 | 97350.0 | 4.0 | False | None | None | False | None | False | 389400.0 | 0 | 2958125 | 97759 | None | Code93 | Supplying Installing, testing and commissioning of Response Indicator constists of twin LED wioth electronic circutarx work on 24 DC enclose in PVC retangular. complete including cost of materials, labour, HOM complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 324.5 | 324.5 | 100.0 | False | None | None | False | None | False | 32450.0 | 0 | 2958126 | 97759 | None | Code94 | Supply, Installation , Testing & Commissioning of Network Active Repeater Panel with 1500 Character / 240X64 Pixel / 7inch Touchscreen. The LCD shall Display all events / detectors, devices status of complete systems in the networked. Approval: UL/VDS/EN54. Make: ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 84370.0 | 84370.0 | 1.0 | False | None | None | False | None | False | 84370.0 | 0 | 2958127 | 97759 | None | Code95 | Supply, intallation, testing and Commissioning of loop card ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3634.4 | 3634.4 | 4.0 | False | None | None | False | None | False | 14537.6 | 0 | 2958128 | 97759 | None | Code96 | Supply Installation testing & Commissioning of conventional type photo/Heat
electric smoke sensor with flashing LED capable of woking at 9V to 33 V DC .The
Optical Smoke Detector is unaffected by wind or atmosphericpressure and operates over the temperature range -20C to +60C. IP Rating at IP 23D & Approval with EN-54 -7, LPCB Approved. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2725.8 | 2725.8 | 350.0 | False | None | None | False | None | False | 954030.0 | 0 | 2958129 | 97759 | None | Code97 | SITC OF Fault isolation module:- Supply, Erection,Testing and Commissioning of UL-APPROVED Analog addressable fault isolator circuit modules of wall mounted type with mounting accessories. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7788.0 | 7788.0 | 20.0 | False | None | None | False | None | False | 155760.0 | 0 | 2958130 | 97759 | None | Code98 | Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Sounder & Beacon with inbuilt isolator and having Min 15 distinct sound patterns/ multitone to indicate Exit doors and direct occupants for safe and fast evacuation and 100dB output with minimum 1Hz Frequency flash rate designed for IP65 requirements and approved to operate in 10C to +55C temperature, complies with the essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. (For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: VDS/UL/EN54. Make: Advanced (UK),Simplex, Notifier,Argus(Uk) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6360.2 | 6360.2 | 12.0 | False | None | None | False | None | False | 76322.4 | 0 | 2958131 | 97759 | None | Code99 | Supplying Installing, testing and commissioning of Resettable type Manual Call point . works on 24V DC LED indicator with glass Fronted. Fire Symbol .The red Manual Call Point is approved to EN54-11 standard. MECHANICAL CONSTRUCTION The component parts of the call point are moulded in polycarbonate or ABS, depending on their function. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3894.0 | 3894.0 | 12.0 | False | None | None | False | None | False | 46728.0 | 0 | 2958132 | 97759 | None | Code100 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.100 x 75 x 65 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 153.16 | 153.16 | 350.0 | False | None | None | False | None | False | 53606.0 | 0 | 2958133 | 97759 | None | Code101 | Supply, install, test and commissioning of Analogue addressable Monitor Cum
Control (Input/Output) module (1+1) with inbuilt relay and isolator with LED
indicator, approved to operate in 10C to +55C temperature, complies with the
essential requirement of the EMC Directive to be supplied with Junction Box, Glands and other mounting accessories for proper installation. In case of Manufacturer with single Input or Output module need to supply One quantity of each for line item.(For Detectors/Device without inbuilt isolator, Fault Isolator or Isolator base to be provided with each detector/device) Approval: EN54. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5062.2 | 5062.2 | 12.0 | False | None | None | False | None | False | 60746.4 | 0 | 2958134 | 97759 | None | Code102 | Supply, intallation, testing and Commissioning of 2C 1.5 sq mm armoured FRLS cables in celing with suitable clamps and screws (RED colour) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 224.55 | 224.55 | 4750.0 | False | None | None | False | None | False | 1066612.5 | 0 | 2958135 | 97759 | None | Code103 | SITC of 7AM-12 V Battery for fire alarm system ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1390.16 | 1390.16 | 6.0 | False | None | None | False | None | False | 8340.96 | 0 |
| 1709805443000 | 0 | None | None | Buildings | HVAC | 24965196.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958136 | 97760 | None | Code01 | Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit.5 Star-1.0 Ton Capacity. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 56117.26 | 56117.26 | 10.0 | False | None | None | False | None | False | 561172.6 | 0 | 2958137 | 97760 | None | Code02 | Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit.5 Star-1.5 Ton Capacity. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 66498.9 | 66498.9 | 8.0 | False | None | None | False | None | False | 531991.2 | 0 | 2958138 | 97760 | None | Code03 | Supplying of ..... TR Invertor type split Air conditioners suitable for operation on A/C supply single phase 230V/50Hz with hermetically sealed inverter compressor with air cooled condenser, latest R410A / R-32 Refrigerant fan motor, start & run capacitors, relay & over load protector internal unit, with one indoor & one outdoor unit. The condenser unit will be placed outside the room avoid noise including standard length of suitable size copper tubing covered with nitrile rubber insulation tube. Suitable capacity 3 Core sheathed/PVC copper cable and a battery operated wireless remote unit.5 Star-2.0 Ton capacity. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 79530.82 | 79530.82 | 14.0 | False | None | None | False | None | False | 1113431.48 | 0 | 2958139 | 97760 | None | Code04 | Supply, erection, testing, commissioning of Supplying, Erecting, Testing, commissioning of sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit.-2.0 TR Cassette 1 Ph ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 93001.7 | 93001.7 | 4.0 | False | None | None | False | None | False | 372006.8 | 0 | 2958140 | 97760 | None | Code05 | Supply, erection, testing, commissioning of Supplying, Erecting, Testing, commissioning of sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit.-3.0 TR Cassette 3 Ph ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 124038.06 | 124038.06 | 3.0 | False | None | None | False | None | False | 372114.18 | 0 | 2958141 | 97760 | None | Code06 | Supply, erection, testing, commissioning of Supplying, Erecting, Testing, commissioning of sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit.-4.0 TR Cassette 3 Ph ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 141860.78 | 141860.78 | 1.0 | False | None | None | False | None | False | 141860.78 | 0 | 2958142 | 97760 | None | Code07 | Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.-3.0 TR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 101251.08 | 101251.08 | 1.0 | False | None | None | False | None | False | 101251.08 | 0 | 2958143 | 97760 | None | Code08 | Supply, erection, testing, commissioning of package type Duct able type split Air-Conditioner with microprocessor control, fitted with twin scroll Compressor with R22/Latest Refrigerant. The unit shall be pre-wired to operate on 415V/50Hz AC Supply. The unit shall comprise, Evaporated condenser unit, Indoor-Outdoor Motor Fans, suitable over vent fins made up of Aluminium, Copper Refrigerant coil, Etc.,. complete and corded control unit.-5.5 TR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 133468.62 | 133468.62 | 2.0 | False | None | None | False | None | False | 266937.24 | 0 | 2958144 | 97760 | None | Code09 | Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable angle iron support upto 3.0 Ton split/cassette type A/C. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3746.5 | 3746.5 | 32.0 | False | None | None | False | None | False | 119888.0 | 0 | 2958145 | 97760 | None | Code10 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube.-Split ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1827.82 | 1827.82 | 195.0 | False | None | None | False | None | False | 356424.9 | 0 | 2958146 | 97760 | None | Code11 | Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit leak testing oil and gas charging for additional piping length of tube.-Cassette ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1934.02 | 1934.02 | 60.0 | False | None | None | False | None | False | 116041.2 | 0 | 2958147 | 97760 | None | Code12 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.-24 Gauge ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2136.98 | 2136.98 | 1400.0 | False | None | None | False | None | False | 2991772.0 | 0 | 2958148 | 97760 | None | Code13 | Supply, fabrication and installation of GI Ducting Along with flanges, supports & all fixing materials.-22 Gauge ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2502.78 | 2502.78 | 225.0 | False | None | None | False | None | False | 563125.5 | 0 | 2958149 | 97760 | None | Code14 | Supply and installation of Thermal insulation using 13mm nitrile rubber for return air ducts. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1405.38 | 1405.38 | 1430.0 | False | None | None | False | None | False | 2009693.4 | 0 | 2958150 | 97760 | None | Code15 | Supply and installation of Tarpaulin canvas between the AC duct and AC evaporator unit including accessories. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 5385.52 | 5385.52 | 21.0 | False | None | None | False | None | False | 113095.92 | 0 | 2958151 | 97760 | None | Code16 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.-Aluminium Diffusers ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 5992.04 | 5992.04 | 430.0 | False | None | None | False | None | False | 2576577.2 | 0 | 2958152 | 97760 | None | Code17 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.-Collar Dampers ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3096.32 | 3096.32 | 195.0 | False | None | None | False | None | False | 603782.4 | 0 | 2958153 | 97760 | None | Code18 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.-GI Mixing Box ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 7404.5 | 7404.5 | 20.0 | False | None | None | False | None | False | 148090.0 | 0 | 2958154 | 97760 | None | Code19 | Supply and installation of Powder coated aluminium diffusers of size 595x595mm for supply & return air.-Flexible Duct Per Mtr ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1996.56 | 1996.56 | 20.0 | False | None | None | False | None | False | 39931.2 | 0 | 2958155 | 97760 | None | Code20 | Supply and fixing of powder coated extruded aluminium grill suitable for supply/return air including all fixing hardware etc.,. Complete. - 6" Extruded aluminium grille with 15 deg to 30 deg louvers. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2008.36 | 2008.36 | 20.0 | False | None | None | False | None | False | 40167.2 | 0 | 2958156 | 97760 | None | Code21 | Supply, Installation, Testing and Commissioning of Customized Double Skin Horizontal Ceiling Mounted type Air Handling Units with Thermal Break profile. (Direct Expansion (DX) refrigerant-to-air evaporator coils, as applied with condensing units with necessary KIT) Sandwitched between 0.8 precoated GI (outer skin) shall be pre coated and 0.8 Plain GI (inner skin) double skin (48+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. AHU frame works shall be of pre cast vertical and horizontal extruded thermal break aluminium profile with three way corner frame sections. Food grade self adhesive coated neoprene gasket to be provided between panels and structure of the AHU to ensure the entire housing is airtight. DIDW centrifugal belt driven backward Aerofoil curved impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor.The outlet velocity will not exceed 9.5 m/sec. Vibration isolatator to fans and motor to avoid transmission of vibration. AHRI Certified DX Cooling coils shall be of minimum 6/8 Row deep or as per computer coil selections which ever is greater. Face Velocity across the coils should not exceed 500 FPM (2.5m/s) (Note : DX Cooling Coil should be Hydrophlic blue aluminium fines.) The AHU unit shall be complete with external DX type condensing unit, complete in all respects, inclusive of complete working charge of R410a/134a Chlorofluorocarbons (CFC) environmentally free refrigerant.Drain tray for DX cooling coils shall be made of single sheet of SS 304-20G grade stainless steel sheet and should have uniform slope from all sides leading to drain connection. Drain Pan shall be insulated with 19mm thick, 55kg/cum density closed cell elastomeric insulation. Each unit filters section shall be provided with a factory assembled filter section containing washable synthetic with 50mm thick panel type Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. (1 set of spare & 1 set of commissioning pre filters should be consider) and Fine-Filter of MERV 13 (EU-7) 97% down to 3 microns. The Motor shall be of TEFC, IP-65 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply. Motor shall be VFD compatible and induction type. Costing is inclusive of Canvas connection made of self extinguishing, moisture resistant flexible fabric to be provided between AHU outlet flange and the supply duct / plenum, communication cable as specfied by manufacturer and Lifting, Shifting & Positioning with MS L angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. Wiring and earthing, vacuum cleaneing, gas charging, pressure testing and etc… are in part of HVAC Vendor scope.Safety interlock switch for fan operation to controle heater on/off to be provided by the AHU manufacturer. Note : Costing is inclusive of Necessary DX type condensing out door units to AHU interface Expansion Connecting Kit (PCB with EEV) & Control Control Panel with sensors, thermostat and etc.., Corded Remote controller for AHU's to precisely control the flow of refrigerant for temperature control. 5.5 TR / 2,200 CFM with 50 TSP - 1.5 Kw for CSU's and 1x5.5 - Condensing units with necessary KIT ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 260780.0 | 260780.0 | 4.0 | False | None | None | False | None | False | 1043120.0 | 0 | 2958157 | 97760 | None | Code22 | 8.5 TR / 3,000 CFM with 50 TSP - 1.5 Kw for CSU's and 1x8.5 - Condensing units with necessary KIT. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 342200.0 | 342200.0 | 5.0 | False | None | None | False | None | False | 1711000.0 | 0 | 2958158 | 97760 | None | Code23 | 11.0 TR / 4,400 CFM with 50 TSP - 2.2 Kw for CSU's and 1x11.0 - Condensing units with necessary KIT. (Location - As per the site condition) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 438960.0 | 438960.0 | 2.0 | False | None | None | False | None | False | 877920.0 | 0 | 2958159 | 97760 | None | Code24 | 15.0 TR / 2,300 CFM with 50 TSP - 1.1 Kw for CSU's and 2x8.5 - Condensing units with necessary KIT ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 553420.0 | 553420.0 | 1.0 | False | None | None | False | None | False | 553420.0 | 0 | 2958160 | 97760 | None | Code25 | 38.0 TR / 6,300 CFM with 50 TSP - 3.7 Kw for CSU's and 3x11 + 1x5.5 - Condensing units with necessary KIT ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1078520.0 | 1078520.0 | 1.0 | False | None | None | False | None | False | 1078520.0 | 0 | 2958161 | 97760 | None | Code26 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
1/4" (6.35 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1180.0 | 1180.0 | 175.0 | False | None | None | False | None | False | 206500.0 | 0 | 2958162 | 97760 | None | Code27 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
3/8" (9.52 mm) X 21 Swg (0.8mm) - Soft drawn (Insulation = 13mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1298.0 | 1298.0 | 175.0 | False | None | None | False | None | False | 227150.0 | 0 | 2958163 | 97760 | None | Code28 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
1/2" (12.7 mm) X 21 Swg (0.8 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1416.0 | 1416.0 | 375.0 | False | None | None | False | None | False | 531000.0 | 0 | 2958164 | 97760 | None | Code29 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
5/8" (15.9 mm) X 19 Swg (1 mm) - Soft drawn (Insulation = 13mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1652.0 | 1652.0 | 300.0 | False | None | None | False | None | False | 495600.0 | 0 | 2958165 | 97760 | None | Code30 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
3/4" (19.05 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 13mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1770.0 | 1770.0 | 75.0 | False | None | None | False | None | False | 132750.0 | 0 | 2958166 | 97760 | None | Code31 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
7/8" ( 22.2 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1888.0 | 1888.0 | 125.0 | False | None | None | False | None | False | 236000.0 | 0 | 2958167 | 97760 | None | Code32 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
1.0" (25.4 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2006.0 | 2006.0 | 100.0 | False | None | None | False | None | False | 200600.0 | 0 | 2958168 | 97760 | None | Code33 | Supply, installation, testing and commissioning of Interconnecting Soft drawn / Hard drawn Refrigerant copper Piping with insulation with UV protection coating.
Note:
a) To protect Nitrile rubber insulation of outdoor installed copper piping from degradation due to ultra violet rays and atmospheric condition.
b) UV protection coating on existing copper pipes (with insulation) shall be done with the help of starbond and 7mm cloth etc. UV protection coating shall be done on all the pipes irrespective of size of pipes
work duly insulated with 13mm & 19mm thick elastomeric nitrile rubber type tubular insulation between VRV/VRF/DX Type indoor & outdoor units.
Note :
c) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
d) Refrigerant copper Piping quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
e) Actual measurement of Refrigerant copper Piping quantity (mtr) should be taken as per site condition only.
1 1/8" (28.6 mm) X 19 Swg (1 mm) - Hard drawn (Insulation = 19mm thick) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2124.0 | 2124.0 | 375.0 | False | None | None | False | None | False | 796500.0 | 0 | 2958169 | 97760 | None | Code34 | 1,000 CFM / 40 mm TSP / 1.1 kW - Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
1,000 CFM / 40 mm TSP / 1.1 kW ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 35400.0 | 35400.0 | 3.0 | False | None | None | False | None | False | 106200.0 | 0 | 2958170 | 97760 | None | Code35 | 1,500 CFM / 40 mm TSP / 1.1 kW - Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 53100.0 | 53100.0 | 1.0 | False | None | None | False | None | False | 53100.0 | 0 | 2958171 | 97760 | None | Code36 | 2,000 CFM / 40 mm TSP / 1.1 kW - Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Fresh air Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns. Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories.Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 70800.0 | 70800.0 | 1.0 | False | None | None | False | None | False | 70800.0 | 0 | 2958172 | 97760 | None | Code37 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Exhaust Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns, HEPA filter, Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories..Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts.
2,500 CFM / 90 mm TSP / 2.1 kW ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 94400.0 | 94400.0 | 1.0 | False | None | None | False | None | False | 94400.0 | 0 | 2958173 | 97760 | None | Code38 | Supply, Installation, Testing and Commissioning of Double Skin Horizontal Ceiling/Floor Mounted Cabinet type Exhaust Units Sandwitched between 0.6 precoated GI (outer skin) shall be pre coated and 0.6 Plain GI (inner skin) double skin (23+/-2 mm) insulated with CFC free polyurethane foam (PUF) panels of 40 Kg/cum density. with DIDW centrifugal belt driven backward curved Aerofoil impeller fans (Efficiency with 75%) (AMCA Certified) to be supplied along with motor. Vibration isolatator to fans and motor to avoid transmission of vibration, Motor, Pulleys, Belts & Belt guard, Pre-Filter of MERV 8 (EU-4)- 90% down to 10 microns, HEPA filter, Drive sets, base frame, spring mounts, Limit switches, Marine lamp, Inspection door and all necessary accessories..Blower Make - Nicotra / Kruger.
The unit shall be suitable for outdoor application with necessary weather hood, canopy and supports with necessary MS channels & threaded rods.
The Motor shall be of TEFC, IP-55 protected, IE-3, Class 'F' insulation, suitable for 3 phase, 415 volts, 50hz power supply.
Motor shall be VFD compatible and induction type. VFD starter panel cost quantified separately (Cost excluded for the same).Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh air units outlet flange and the connected plenum or ducts. - 6,000 CFM / 90 mm TSP / 5.5 kW ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 283200.0 | 283200.0 | 1.0 | False | None | None | False | None | False | 283200.0 | 0 | 2958174 | 97760 | None | Code39 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
150 CFM / 20mm TSP. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 8850.0 | 8850.0 | 5.0 | False | None | None | False | None | False | 44250.0 | 0 | 2958175 | 97760 | None | Code40 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts.
300 CFM / 20mm TSP. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 12390.0 | 12390.0 | 2.0 | False | None | None | False | None | False | 24780.0 | 0 | 2958176 | 97760 | None | Code41 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts. 500 CFM / 20mm TSP. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 15930.0 | 15930.0 | 9.0 | False | None | None | False | None | False | 143370.0 | 0 | 2958177 | 97760 | None | Code42 | Supply, Installation, Testing & Commissioning of Rectangular / Circular inline fan with variable speed regulator with suitable for installing in any position in vertical or horizontal ducts. All accessories like fan, motor, flanges, non-canvass type fire retardant flexible connections, etc., The impeller shall be of forward type. The motor should be of IP21, class 'B' insulation suitable for operating at 1phase, 230V, 50hz power supply.
Note : Rectangular / Circular inline fan shall have low sound level exceeding not more than 40 dBA at 1 meter distance.
Note: Costing is inclusive of Factory fabricated non-cloth type Fire retardant flexible connection made of high quality self extinguishing, moisture resistant flexible fabric with matching angle flanges between Fresh/Exhaut air units outlet flange and the connected plenum or ducts. - 700 CFM / 20mm TSP. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 17110.0 | 17110.0 | 4.0 | False | None | None | False | None | False | 68440.0 | 0 | 2958178 | 97760 | None | Code43 | Supply, Installation, Testing & Commissioning of Open cell "Class-1" Nitrile rubber Insulation for Duct Acoustics insulation with Ultrafresh Antimicrobial protection as per ASTM G21, ASTM G22, UL-181 and E2180 , Density 140-180Kg / m3, UL94 approved (HBF, HF 1 & HF 2) in accordance to UL 94,1996. Thermal conductivity 0.047 W / MK at 20 Deg C, Air Erosion Resistance test Confirming to ASTM Standard C 1071-05 (section 12.7).
Moisture resistant-joining tapes of 2 inches width with self adhesive to be supplied with the insulation material by the supplier.
Use Low Voc Adhesive. (Adhesive VOC level as per LEED requirement)
Note - if the adhesive is not self adhiesive type then the glue should be used with the same manufacturer.
15mm Thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1298.0 | 1298.0 | 200.0 | False | None | None | False | None | False | 259600.0 | 0 | 2958179 | 97760 | None | Code44 | Supply, Installing, testing and commissioning of closed cell Nitrile Rubber with IC CLADING (7 mil Fibre glass cloth) and Two Coats of protecticve coating.
Note :Used for Exposed Ventilaion ducting at out side of the building and terrace. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 472.0 | 472.0 | 100.0 | False | None | None | False | None | False | 47200.0 | 0 | 2958180 | 97760 | None | Code45 | Supply, Installation, Testing & Commissioning of Fire damper with opposed blade (Fusible link type). Fire damper as per UL 555, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection. The damper shall be of 90 min fire rating with Fusible Link & spring mechanism the damper shall be held open by a replaceable fusible link rated at 74 deg C.
(Area calculation : (L x B)) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 15340.0 | 15340.0 | 7.0 | False | None | None | False | None | False | 107380.0 | 0 | 2958181 | 97760 | None | Code46 | Supply, Installation, Testing & Commissioning of Quadrant type Volume controle Damper (VCD). The volume control damper shall be of low leakage type with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS and with necessary flanges for connection etc.,
(Area calculation : (L x B)) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 9440.0 | 9440.0 | 7.0 | False | None | None | False | None | False | 66080.0 | 0 | 2958182 | 97760 | None | Code47 | Supply, Installation, Testing & Commissioning of Back draft damper (BDD). The Back draft damper with the outer shell constructed of 1.6mm thick galvanized steel frame and the blade/Leaf with 1mm thick aluminum and with necessary flanges for connection and as per specifications.
(Area calculation : (L x B)) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 10620.0 | 10620.0 | 1.0 | False | None | None | False | None | False | 10620.0 | 0 | 2958183 | 97760 | None | Code48 | Supply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange.
250 dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2360.0 | 2360.0 | 25.0 | False | None | None | False | None | False | 59000.0 | 0 | 2958184 | 97760 | None | Code49 | Supply, Installation, Testing & Commissioning of Butterfly Damper GI Constructed Single Flap with round flange on one side and 10mm grove on other side for fixing of flexible duct with the help of band. 20G GI constructed self lubricated bronze Bushes and 1.6mm flange. - 300 dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2950.0 | 2950.0 | 25.0 | False | None | None | False | None | False | 73750.0 | 0 | 2958185 | 97760 | None | Code50 | Supply, Installation, Testing and Commissioning of Aluminium Collar Damper of opposed blade type aluminum extruded construction black anodized dampers. (Used in supplay air) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 7670.0 | 7670.0 | 1.5 | False | None | None | False | None | False | 11505.0 | 0 | 2958186 | 97760 | None | Code51 | Supply, Installation, Testing & Commissioning of Extruded Aluminum powder coated Exhaust air Disc valves/grille without volume control dampers for Pantry. a) Note: Colour shall be as per the False ceiling or Architect intent.
150 mm Dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1475.0 | 1475.0 | 25.0 | False | None | None | False | None | False | 36875.0 | 0 | 2958187 | 97760 | None | Code52 | Supply, installation, testing and commissioning of Extruded Al. Powder coated Fresh air / Exhaust air louvers with slimline blade (3 mm nominal thickness) grille height 16 mm, blade pitch 12.5 mm and blade angle 0/15 degree deflection without damper and with end flanges.
Note: Colour shall be as per the False ceiling or Architect intent. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 10620.0 | 10620.0 | 5.0 | False | None | None | False | None | False | 53100.0 | 0 | 2958188 | 97760 | None | Code53 | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes.
40 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 590.0 | 590.0 | 108.0 | False | None | None | False | None | False | 63720.0 | 0 | 2958189 | 97760 | None | Code54 | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. - 32 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 531.0 | 531.0 | 96.0 | False | None | None | False | None | False | 50976.0 | 0 | 2958190 | 97760 | None | Code55 | Supply, Installation, Testing & Commissioning of Condensate CPVC drain piping with insulated with 6mm Nitrile rubber insulation including elbows, connectors, U traps, Y-connections and flexible tubing for all indoor units to the nearest drain points / toilet drain / pantry drain / HVAC shaft available as per approved shop drawings or site conditions and as per directions of the Consultant and Architect. The quote should inclusive of all Hardware necessary to secure the pipes. - 25 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 413.0 | 413.0 | 456.0 | False | None | None | False | None | False | 188328.0 | 0 | 2958191 | 97760 | None | Code56 | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Blanc Pumps (External) for Hi-Wall units. (Max. flow 12L/h & Head is 10Met) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 8260.0 | 8260.0 | 31.0 | False | None | None | False | None | False | 256060.0 | 0 | 2958192 | 97760 | None | Code57 | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Mini Tank Pump (Less then 5.0 TR CSU/FCU) - (Max. flow 35L/h & Head is 15Met) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9440.0 | 9440.0 | 1.0 | False | None | None | False | None | False | 9440.0 | 0 | 2958193 | 97760 | None | Code58 | Supply, Installation, Testing & Commissioning of Drain Pumps for CHW/VRV/VRF/DX Type Hi-Wall Units and Ceiling Mounted Units.
Max Hi-Flow (Above 5.0 TR CSU/FCU) - (Max. flow 550L/h & Head is 5Met) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10620.0 | 10620.0 | 15.0 | False | None | None | False | None | False | 159300.0 | 0 | 2958194 | 97760 | None | Code59 | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp)
Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
1.5 Kw ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 8260.0 | 8260.0 | 3.0 | False | None | None | False | None | False | 24780.0 | 0 | 2958195 | 97760 | None | Code60 | Supply, Installation, Testing & Commissioning of Duct type Strip heater (For Customized AHU's) with nessacery electrical wiring and connection. Incoming power supply from respactive Starter panel. (Used in Winter season to achiev the room Temp)
Heater bank & Duct befer and after the Heater bank should be panted in RED for 150mm on either side of the Heater bank.
3.0 Kw ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11800.0 | 11800.0 | 10.0 | False | None | None | False | None | False | 118000.0 | 0 | 2958196 | 97760 | None | Code61 | Supply, Installation, Testing & Commissioning of Magnehelic Differential Pressure Gages (IP-67 enclosure) to Indicate Positive, Negative or Differential, Accurate within 1%. Note: Pressures must be less than 35 psi.
Mounting Orientation:Diaphragm in vertical position. Consult factory for other position orientations.
Costing is inclusive of with necessary fittings and Pitot Tube and etc..
AHU/CSU Filter Section ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11210.0 | 11210.0 | 13.0 | False | None | None | False | None | False | 145730.0 | 0 | 2958197 | 97760 | None | Code62 | Supply, Installation, Testing & Commissioning of Duct Type Temperature & RH Sensors (IP-40 enclosure) (Immersion depth : 230 mm) with all mounting accessories to measure the Return Air temperatures.
(Temperature range : -0C to 55C & R.H. range 10% to 90%)
Note : Used for AHU's, CSU's FCU's & Cassette units. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10030.0 | 10030.0 | 13.0 | False | None | None | False | None | False | 130390.0 | 0 | 2958198 | 97760 | None | Code63 | Supply, Installation, Testing & Commissioning of Room Type Temperature & RH Digital Sensors (Thermostats) with all mounting accessories to measure the critical Room air temperatures.
(Temperature range : -20C to 60C & R.H. range 0% to 99%) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10030.0 | 10030.0 | 13.0 | False | None | None | False | None | False | 130390.0 | 0 | 2958199 | 97760 | None | Code64 | 1.1 kW (DOL) - Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Customized DX/CHW AHU's Equipment DOL, Star / Delta with VFD Provision Starters and Motorized Fire damper controle panel with minimum IP-54 rating. (Additional Enclosures not acceptable)
Starter panel should have TPN+E and inbuilt (230V To 24V) step down transformer for Fire damper actuator & Self-balancing, Pressure independent type dynamic balancing Valve (PIBCV) actuators.
5% non-saturating dual reactors on both rails of DC bus. Swinging chokes which do not provide full harmonic filtering throughout the entire load range are not acceptable. VFDs with saturating (non-linear) DC reactors to provide additional 3% AC chokes. Shall comply with requirements of IEC 61800-3 : 2004, Category C1 with 50m motor cable (Unrestricted Distribution). VFD shall be suitable to satisfactory work on 415 + 10% voltage range.
Three-feedback PID controllers to control the speed of the VFD & other functions.
VFD must have min. 2 PID controllers inbuilt to control Chilled water valve, VFD speed etc. as per requirement.VFD shall be capable of withstanding 100 K Amperes Short circuit current at Output terminals.The complete VFD shall be factory manufactured and tested and no external component shall be allowed. Test certificate of each VFD (serial Numberwise) shall be furnished by supplier.The VFD shall be provided with following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO. Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.BMS compatibility: RS-485 connector with BacNet over IP communication protocol. (Only if the Project is having BMS System)
Note: Once the AHU receive the Start command either Auto/Manual, initially Customized DX/CHW AHU's Supply & Return air duct motorised fire damper should open. After the set time delay (30 to 180 sec) Customized DX/CHW AHU's starter should start the Customized DX/CHW AHU's. During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment.
1.1 kW (DOL) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 2958200 | 97760 | None | Code65 | 3.7 Kw (STAR/DELTA)- Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Customized DX/CHW AHU's Equipment DOL, Star / Delta with VFD Provision Starters and Motorized Fire damper controle panel with minimum IP-54 rating. (Additional Enclosures not acceptable)
Starter panel should have TPN+E and inbuilt (230V To 24V) step down transformer for Fire damper actuator & Self-balancing, Pressure independent type dynamic balancing Valve (PIBCV) actuators.
5% non-saturating dual reactors on both rails of DC bus. Swinging chokes which do not provide full harmonic filtering throughout the entire load range are not acceptable. VFDs with saturating (non-linear) DC reactors to provide additional 3% AC chokes. Shall comply with requirements of IEC 61800-3 : 2004, Category C1 with 50m motor cable (Unrestricted Distribution). VFD shall be suitable to satisfactory work on 415 + 10% voltage range.
Three-feedback PID controllers to control the speed of the VFD & other functions.
VFD must have min. 2 PID controllers inbuilt to control Chilled water valve, VFD speed etc. as per requirement.VFD shall be capable of withstanding 100 K Amperes Short circuit current at Output terminals.The complete VFD shall be factory manufactured and tested and no external component shall be allowed. Test certificate of each VFD (serial Numberwise) shall be furnished by supplier.The VFD shall be provided with following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO. Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.BMS compatibility: RS-485 connector with BacNet over IP communication protocol. (Only if the Project is having BMS System)
Note: Once the AHU receive the Start command either Auto/Manual, initially Customized DX/CHW AHU's Supply & Return air duct motorised fire damper should open. After the set time delay (30 to 180 sec) Customized DX/CHW AHU's starter should start the Customized DX/CHW AHU's. During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 2958201 | 97760 | None | Code66 | Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Customized DX AHU's Equipment DOL, Star / Delta Starters without VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.BMS compatibility: RS-485 connector with BacNet over IP communication protocol. (Only if the Project is having BMS System)
Note : During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment.
1.5 kW (DOL) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 33040.0 | 33040.0 | 9.0 | False | None | None | False | None | False | 297360.0 | 0 | 2958202 | 97760 | None | Code67 | Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Customized DX AHU's Equipment DOL, Star / Delta Starters without VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.BMS compatibility: RS-485 connector with BacNet over IP communication protocol. (Only if the Project is having BMS System)
Note : During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment.
2.2 kW (DOL) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 33040.0 | 33040.0 | 2.0 | False | None | None | False | None | False | 66080.0 | 0 | 2958203 | 97760 | None | Code68 | 2.2 kW (DOL) - Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Ventilation Equipment DOL, Star / Delta Starters with VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
5% non-saturating dual reactors on both rails of DC bus. Swinging chokes which do not provide full harmonic filtering throughout the entire load range are not acceptable. VFDs with saturating (non-linear) DC reactors to provide additional 3% AC chokes. Shall comply with requirements of IEC 61800-3 : 2004, Category C1 with 50m motor cable (Unrestricted Distribution). VFD shall be suitable to satisfactory work on 415 + 10% voltage range.
Three-feedback PID controllers to control the speed of the VFD & other functions.
VFD must have min. 2 PID controllers inbuilt to control Chilled water valve, VFD speed etc. as per requirement.VFD shall be capable of withstanding 100 K Amperes Short circuit current at Output terminals.The complete VFD shall be factory manufactured and tested and no external component shall be allowed. Test certificate of each VFD (serial Numberwise) shall be furnished by supplier.The VFD shall be provided with following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO. Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.BMS compatibility: RS-485 connector with BacNet over IP communication protocol. (Only if the Project is having BMS System)
Note: Once the AHU receive the Start command either Auto/Manual, initially Customized DX/CHW AHU's Supply & Return air duct motorised fire damper should open. After the set time delay (30 to 180 sec) Customized DX/CHW AHU's starter should start the Customized DX/CHW AHU's. During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment.
2.2 kW (DOL) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 2958204 | 97760 | None | Code69 | 5.5 kW (STAR/DELTA)- Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Ventilation Equipment DOL, Star / Delta Starters with VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
5% non-saturating dual reactors on both rails of DC bus. Swinging chokes which do not provide full harmonic filtering throughout the entire load range are not acceptable. VFDs with saturating (non-linear) DC reactors to provide additional 3% AC chokes. Shall comply with requirements of IEC 61800-3 : 2004, Category C1 with 50m motor cable (Unrestricted Distribution). VFD shall be suitable to satisfactory work on 415 + 10% voltage range.
Three-feedback PID controllers to control the speed of the VFD & other functions.
VFD must have min. 2 PID controllers inbuilt to control Chilled water valve, VFD speed etc. as per requirement.VFD shall be capable of withstanding 100 K Amperes Short circuit current at Output terminals.The complete VFD shall be factory manufactured and tested and no external component shall be allowed. Test certificate of each VFD (serial Numberwise) shall be furnished by supplier.The VFD shall be provided with following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO. Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.BMS compatibility: RS-485 connector with BacNet over IP communication protocol. (Only if the Project is having BMS System)
Note: Once the AHU receive the Start command either Auto/Manual, initially Customized DX/CHW AHU's Supply & Return air duct motorised fire damper should open. After the set time delay (30 to 180 sec) Customized DX/CHW AHU's starter should start the Customized DX/CHW AHU's. During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 44840.0 | 44840.0 | 1.0 | False | None | None | False | None | False | 44840.0 | 0 | 2958205 | 97760 | None | Code70 | Designing, Fabrication, Supply, Installation, Testing & Commissioning of Cubical type Ventilation Equipment DOL, Star / Delta Starters without VFD Provision with minimum IP-54 rating. (Additional Enclosures not acceptable)
Alpha numeric Graphical Display with inbuilt energy meter, ammeter, voltmeter etc. and shall be capable of displaying any 5 parameters simultaneously.
Note : During Fire Emergency operation, these panels should receive the Fire Trip signal from the emergency stop push button from the different location, and should stop the respective HVAC Equipment.
1.1 kW (DOL) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 33040.0 | 33040.0 | 3.0 | False | None | None | False | None | False | 99120.0 | 0 | 2958206 | 97760 | None | Code71 | Supply, Installation, Testing & Commissioning of Variable Frequency drives, metering, all accessories, controls, harmonic filters for HVAC equipment.
Drive motors including enclosure & necessary a/m switches and auxiliary contacts for BMS Operation with IP-55 rating variable frequency drive (VFD) with mains disconnect switch suitable for below mentioned motor kw rating.
The final rating of the equipment kW shall be as per the approved shop drawigns & Technical Submittal.
Note : VFD shall be able to connect with BMS of any make, shall take ON/OFF command from remote controller, shall be able to do the following :-
1) scheduling from remote controller.
2) Accept signal from temeprature/ pressure transmitter.
3) Read V, A, Kwh, frequency & RPM & send to remote controller.
4) With following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO.
1.1 kW ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 2958207 | 97760 | None | Code72 | Supply, Installation, Testing & Commissioning of Variable Frequency drives, metering, all accessories, controls, harmonic filters for HVAC equipment.
Drive motors including enclosure & necessary a/m switches and auxiliary contacts for BMS Operation with IP-55 rating variable frequency drive (VFD) with mains disconnect switch suitable for below mentioned motor kw rating.
The final rating of the equipment kW shall be as per the approved shop drawigns & Technical Submittal.
Note : VFD shall be able to connect with BMS of any make, shall take ON/OFF command from remote controller, shall be able to do the following :-
1) scheduling from remote controller.
2) Accept signal from temeprature/ pressure transmitter.
3) Read V, A, Kwh, frequency & RPM & send to remote controller.
4) With following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO.
2.2 Kw ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 19470.0 | 19470.0 | 1.0 | False | None | None | False | None | False | 19470.0 | 0 | 2958208 | 97760 | None | Code73 | Supply, Installation, Testing & Commissioning of Variable Frequency drives, metering, all accessories, controls, harmonic filters for HVAC equipment.
Drive motors including enclosure & necessary a/m switches and auxiliary contacts for BMS Operation with IP-55 rating variable frequency drive (VFD) with mains disconnect switch suitable for below mentioned motor kw rating.
The final rating of the equipment kW shall be as per the approved shop drawigns & Technical Submittal.
Note : VFD shall be able to connect with BMS of any make, shall take ON/OFF command from remote controller, shall be able to do the following :-
1) scheduling from remote controller.
2) Accept signal from temeprature/ pressure transmitter.
3) Read V, A, Kwh, frequency & RPM & send to remote controller.
4) With following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO.
3.7 Kw ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 24662.0 | 24662.0 | 1.0 | False | None | None | False | None | False | 24662.0 | 0 | 2958209 | 97760 | None | Code74 | Supply, Installation, Testing & Commissioning of Variable Frequency drives, metering, all accessories, controls, harmonic filters for HVAC equipment.
Drive motors including enclosure & necessary a/m switches and auxiliary contacts for BMS Operation with IP-55 rating variable frequency drive (VFD) with mains disconnect switch suitable for below mentioned motor kw rating.
The final rating of the equipment kW shall be as per the approved shop drawigns & Technical Submittal.
Note : VFD shall be able to connect with BMS of any make, shall take ON/OFF command from remote controller, shall be able to do the following :-
1) scheduling from remote controller.
2) Accept signal from temeprature/ pressure transmitter.
3) Read V, A, Kwh, frequency & RPM & send to remote controller.
4) With following min. number of IOs: 2 AO / 2 AI / 6 DI / 3 DO.
5.5 kW ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 35046.0 | 35046.0 | 1.0 | False | None | None | False | None | False | 35046.0 | 0 | 2958210 | 97760 | None | Code75 | Supply, installation, testing and commissioning of Electrical Power & Controle cabling for AC units, Ventilation & Pressurization fans units.Note :
a) Costing is inclusive of necessary supports & supporting rods, saddles at 1m interval.
b) Electrical Power cabling quantity (mtr) to be estimated before finalization of order or receipt of work order as per the drawing and take necessary amendment if any variation in the quantity.
c) Actual measurement of Electrical Power cabling quantity (mtr) should be taken as per site condition only.
3.0 Core x 2.5 Sqmm - For AHU/CSU/Ventilation units units.
(Can be used up to 3.7 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 472.0 | 472.0 | 260.0 | False | None | None | False | None | False | 122720.0 | 0 | 2958211 | 97760 | None | Code76 | 3.0 Core x 4.0 Sqmm - For AHU/CSU/Ventilation units units.
(Can be used up to 7.5 Kw / 3Phase)
Flexible Cross-linked polyethylene (XLPE) insulated Armoured copper cables (FRLS) Control & Power cable to connect HVAC or Electrical starter panel to respective HVAC equipment. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 590.0 | 590.0 | 20.0 | False | None | None | False | None | False | 11800.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Modular OT (2 Nos) | 11919536.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958212 | 97761 | None | Code01 | Providing and fixing 50 mm thick prefabricated walkable stainless steel panels ceiling The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick. And these two sheets are held together with aluminum ‘w’ section of 48mm x 10.2mm for frame work & inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The false ceiling panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum ‘H ‘ section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon sealent to ensure air tight vapor tight construction. The false ceiling shall be walkable with provision of service panel. The false ceiling should be fixed to the concrete slab by using 8mm treaded tension bars with adjustable turn buckles, fastener, nuts, bolts etc., complete to the concrete slab.
Coving: Providing corner joint coving for wall to wall used to provide smooth and seamless corner coving buffed aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile.
The required size cut outs for fixing of lights & also for any other services shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift and etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
MODULAR OT area -8 mtr X6 mtr apprxt.
Say 50.00 Sqm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 10354.5 | 10354.5 | 100.0 | False | None | None | False | None | False | 1035450.0 | 0 | 2958213 | 97761 | None | Code02 | Providing and fixing 50 mm thick prefabricated stainless steel wall panels. The panel should have a composite construction of two skins, one side stainless steel 304 grade 0.8 mm thick and other side sheet is PPGI sheet of 0.6 mm thick and these two sheets are held together with aluminum W section size 48mm x 10.2mm for frame work and inner space between two sheets is filled with Puff insulation with density of 40KG per Cubic meter. The panel size should be 1.20Mts x 3.00 Mtrs. The stainless steel surface should be brush / MAT finish with antiglare property. The wall panels are designed in such way that to fit within each other. There shall be minimum joints. If joints are necessary the panels will be jointed each other by using aluminum H section 29 mm x 42 mm for interlock system. And all panel joints will be sealed by using compressible food grade silicon to ensure air tight vapour tight construction. Coving:Providing corner joint coving used to provide smooth and seamless corner coving buffed Aluminium extruded profile R75 ‘C’ cap, L section profile, ‘Z’ section profile. The covings shall be provided wall to wall, wall to ceiling, wall to floor. The required size cut outs for fixing of control panel and switch plate shall be made. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
( Note: The panel should be free from scratches & dents )
6 mtr X 3 mtr X2 Nos. =36 Sqmtr
8 mtr X 3 mtr X2 Nos. =48 Sqmtr
Say 84.00 Sqm
( Door area will be detected form wall panel) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 10354.5 | 10354.5 | 168.0 | False | None | None | False | None | False | 1739556.0 | 0 | 2958214 | 97761 | None | Code03 | Supplying and Fixing STAINLESS STEEL DOOR Providing, fabrication and fixing of Stainless steel door with openable shutter of suitable size. The Door frame section of 50mm x 100mm size is made out of 1.2mm thick Stainless steel sheet of 304 grade. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges. The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including heavy duty SS ball bearing butt door hinges, SS 304 grade handles- 02 sets, heavy duty door closure, SS concealed Tower Bolt, etc are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge.
Srub Door /Dirty utility Door (single leaf)
1 mtr X 2.10 mtr
Say 2.10 Sqmtr ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 53843.4 | 53843.4 | 4.2 | False | None | None | False | None | False | 226142.28 | 0 | 2958215 | 97761 | None | Code04 | Supplying and Fixing HERMATICALLY SEALED STAINLESS STEEL SLIDING DOOR Providing, fabrication and fixing of manually operated hermetically sealed stainless steel sliding door of size1500 x 2100mm. The door shutter of 42 - 45 mm thick by using 0.8mm thick stainless sheet of 304 grade for both sides and the surface of the steel should be MAT finish with antiglare property and having composite construction & the space b/w two sheets is filled with Puff insulation with 40 kg/cum density shall be used to ensure air tight & vapour tight construction. The sliding Door runs on Nylon wheel within an Aluminium extrusion high quality rail complete with required accessories. The door track is constructed from an aluminium extrusion, fixed firmly to the wall. Door shall be provided with automatic drop seal at bottom of door, sealed with high quality neoprene sealing gasket in all edges.
The doors are provided with vision panel in double toughened glass size 300mm x 300mm,(6mm thick). All accessories including SS 304 grade handles- 02 sets, SS concealed Tower Bolt, etc., Complete are all approved make. The cost includes the cost of all materials, labour charges for fixing, transportation, lead, lift etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 96585.36 | 96585.36 | 7.0 | False | None | None | False | None | False | 676097.52 | 0 | 2958216 | 97761 | None | Code05 | Antistatic Epoxy Flooring : Providing and laying 4mm thick anti-static,anti-fungal and anti-bacterial epoxy flooring after preparing the floor surface by removing all loose particles, dirt by using coir brush and vacuum cleaner. Applying one coat of Moisture barrier primer and then applying self-leveling 2mm thick moisture barrier layer to capture the moisture of the existing flooring. Then the anti static grid is laid with conductive granules and copper strips. Then apply one coat of epoxy based primer and allow for dry 6- 8 hours. Then apply epoxy putty and allow for dry 6 to 8 hours. And then apply 2 mm thick self-leveling epoxy flooring of approved make, colour and shade. The Epoxy flooring should be impact resistance, chemical resistance including abrasion and fumigation with R75mm coving wall to wall, wall to flooring etc., The cost includes cost of material, labour, transportation etc., complete. The works shall be carried out as per the directions of the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 3835.0 | 3835.0 | 108.0 | False | None | None | False | None | False | 414180.0 | 0 | 2958217 | 97761 | None | Code06 | Supplying and Fixingof 2'x2' LED recessed luminarie with…. Watts system wattage. Housing shall be with pressure die cast aluminium alloy with corrosion proof resistant polyester powder coated. Driver operates with voltage range from 100v to 270V 50/60 Hz with short circuit, overload & mis-wring protection. Lumen maintenance of 70% at 50000 Hrs. injection moulded poly carbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect. Junction temperature shall be 70 degree Celsius. Driver is on constant current driver @ 0.06A with PF 0.9, line voltage @ 50Hz, driver efficiency 85% & THD15%. LED Efficiency 130 Im/W & Fixture Efficiency 75lm/w with CRI 75 with injection moulded Polycarbonate lens with 8mm depth. 5 years Warranty against any manufacturing defect working under standard electrical condition.] ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9725.56 | 9725.56 | 16.0 | False | None | None | False | None | False | 155608.96 | 0 | 2958218 | 97761 | None | Code07 | Supplying and Fixing LED - X-Ray Viewing Screen :X-RAY VIEWING SCREEN: - Two Plate X-Ray View Screen with flicker free illumination having imported LED system for uniform illumination and operated by X-ray film. The system having electrical safety codes for high & Low voltage system. The X ray viewing screen shall be concealed with wall panel. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 33040.0 | 33040.0 | 2.0 | False | None | None | False | None | False | 66080.0 | 0 | 2958219 | 97761 | None | Code08 | Supplying and Fixing Magnetic Writing List Board:Magnetic Writing Board of size 940 x 640 x 50 mm comprises of a flush mounted, 1.50 mm thick, white laminate board, bonded to a 10 mm high density fibre board sheet for additional rigidity. Magnetic Writing List Board shall be concealed with wall panel. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6903.0 | 6903.0 | 2.0 | False | None | None | False | None | False | 13806.0 | 0 | 2958220 | 97761 | None | Code09 | Supply and installation of Stainless steel 304 grade Plenum LAMINAR FLOW- Plan air Ceiling mounted system with unidirectional airflow,(Air flow velocity of 25 to 35 FPM) Plenum unit, Holding structure & Top plenum are conforming to DIN 4799 / EU14 (Mini pleate HEPA filter) standards for the air distribution system complete with provision for 6 Nos. (Size 1220mmX610mmX90mm thick) HEPA Filters (efficiency 99.97% down to 0.3 micron ), 4000 cfm. The Plenum size is 1800 x 2400mm. The Diffuser is made out of SS 304 Grade material for laminar of filtered air. The complete unit will have factory prepared fine sealing system. It will be perfectly seamless. It will be made out of SS 304 Sheet of required thickness With perforated SS 304 sheet with etc., complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 312700.0 | 312700.0 | 2.0 | False | None | None | False | None | False | 625400.0 | 0 | 2958221 | 97761 | None | Code10 | Supplying and Fixing STAINLESS STEEL STORAGE UNIT:Providing and supplying Storage Unit of size 800x1900x350 mm has made of 0.8.mm thick SS304 grade sheet. The exterior openable glass doors shall be made by using 6mm thick toughened glass with lockable & magnetic push-button for easy opening. Removable toughened glass shelves of thickness 6 mm will be provided with the storage units. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 2958222 | 97761 | None | Code11 | Supplying and Fixing PASS/HATCH BOX:Providing and fixing Hatch box for modular OT in stainless steel SS 304, SS Handles, SS Hinges, View window, Door close/open indication, Electromagnetic door interlocking system based on Microcontroller electronic system for disposal of dirty linen/waste to non-sterile store.(Size 600mm x 600mm x 600mm) with double door inter lock and consisiting of UV lamp, UV lamp on for both door closed, UV lamp off for any door open, CF lamp on any door is open CF lamp off both door closed including cost of conceted accessories. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 76700.0 | 76700.0 | 2.0 | False | None | None | False | None | False | 153400.0 | 0 | 2958223 | 97761 | None | Code12 | Supplying and Fixing OT control Panel 6 Tile : Supply and installation of 6 tile OT control panel with distribution box, control panel will be mounted flush in the theatre wall, comprising of the following1. Medical gas card2. Laminar Air flow controls Temperature & humidity indicators, filter status, temperature & humidity control.3. Digital elapsed timer 4. Hand free phone5. Digital day timer clock6. Lighting control panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 129800.0 | 129800.0 | 2.0 | False | None | None | False | None | False | 259600.0 | 0 | 2958224 | 97761 | None | Code13 | Providing & fixing SS304 grade return air grill. The cut out for return air grill size in panel is 600mmX450mm. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4130.0 | 4130.0 | 8.0 | False | None | None | False | None | False | 33040.0 | 0 | 2958225 | 97761 | None | Code14 | SUPPLY ERECTION TESTING & COMISSIONING of Return air riser made out of SS 304 grade with 18 SWG in the clean room area of 1000 CFM and provision for return air collar damper anf grill with all concted accessories. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 21240.0 | 21240.0 | 8.0 | False | None | None | False | None | False | 169920.0 | 0 | 2958226 | 97761 | None | Code15 | Supplying and Fixing Providing and making trap door of size 600 x 600mm in the ceiling panel by cutting. The required frame work shall be made by using Aluminium sections. The cost includes cost of material, labour charges for fixing etc complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7375.0 | 7375.0 | 2.0 | False | None | None | False | None | False | 14750.0 | 0 | 2958227 | 97761 | None | Code16 | SUPPLY ERECTION TESTING & COMISSIONING Air handling units of GSS powder coated sheet metal cabinet type Double skin Recirculatory type 40-45 mm thick,Thermal break,modular construction.Air handling units shall be complete with Backward curved blower having capacity of 3500 t0 4000 cfm (Minimum 25 to 35 ACPH ) with 125 mm capacity, 3.75kw TEFC motor,fan motor drive filter section with 10 microns pre filter,3 microns fine filters, DX coil 6 row section of copper coil with aluminium fins,Mist eleminator, inlet and outlet volume control dampers and bypass dampers with access doors and accessories including 10% Fresh air with module with console type and grill, 20 Microns Fresh air filter. 10% Bleed module with hepa filter,damper and grille, View glass, View lamp, limit switch for door & Pressure port for filter sections & provision to fix pressure port to measure the pressure drop across the filter, ( EFF1 Motor ) coil should be 5. 5 TR x 2 circute with all concted accessories. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 597788.0 | 597788.0 | 2.0 | False | None | None | False | None | False | 1195576.0 | 0 | 2958228 | 97761 | None | Code17 | SUPPLY ERECTION TESTING & COMISSIONING 5.5 TR Air cooled out door condensing units comprising of semi -hermetic / hermetic reciprocating/scrool compressors with matching air cooled condenser suitable for 3500 to 4000 CFM AHU) provided with necessary controls.like Thermostart , Draier with MS painted stand ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 146320.0 | 146320.0 | 4.0 | False | None | None | False | None | False | 585280.0 | 0 | 2958229 | 97761 | None | Code18 | SUPPLY ERECTION TESTING & COMISSIONING Collar damper made out of Al. with powder coated as per return air openinig size ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 10384.0 | 10384.0 | 4.0 | False | None | None | False | None | False | 41536.0 | 0 | 2958230 | 97761 | None | Code19 | SUPPLY ERECTION TESTING & COMISSIONING Aluminium Volume control dampers manual operated, Only for hepa module, unit mouth & branch Ducts ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 13924.0 | 13924.0 | 4.0 | False | None | None | False | None | False | 55696.0 | 0 | 2958231 | 97761 | None | Code20 | SUPPLY ERECTION TESTING & COMISSIONING Fire Dampers with Fusible Links rated for 72 C for AHU mouth, with fire damper actuator with inter link with AHU controll panel in case of fire AHU motor should stop. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 6254.0 | 6254.0 | 2.0 | False | None | None | False | None | False | 12508.0 | 0 | 2958232 | 97761 | None | Code21 | SUPPLY ERECTION TESTING & COMISSIONING Fire retardant flexible connections for AHU supply & return air mouth ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 5546.0 | 5546.0 | 4.0 | False | None | None | False | None | False | 22184.0 | 0 | 2958233 | 97761 | None | Code22 | SUPPLY ERECTION TESTING & COMISSIONING Al. ducting including the supports,selicon sealent with painted MS angle flanges. - 22 guage ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2006.0 | 2006.0 | 320.0 | False | None | None | False | None | False | 641920.0 | 0 | 2958234 | 97761 | None | Code23 | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade-13 mm thk for return air duct ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 920.4 | 920.4 | 160.0 | False | None | None | False | None | False | 147264.0 | 0 | 2958235 | 97761 | None | Code24 | SUPPLY ERECTION TESTING & COMISSIONING Supply & return air duct Insulation with factory laminated Al. foil class 'O' grade-19 mm thk for supply air duct ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1097.4 | 1097.4 | 180.0 | False | None | None | False | None | False | 197532.0 | 0 | 2958236 | 97761 | None | Code25 | Polishield covering with two coats paint for exposed duct ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1038.4 | 1038.4 | 140.0 | False | None | None | False | None | False | 145376.0 | 0 | 2958237 | 97761 | None | Code26 | SUPPLY & Fixing 300 dia Insulated flexible connection for grille module & return air raiser ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 979.4 | 979.4 | 40.0 | False | None | None | False | None | False | 39176.0 | 0 | 2958238 | 97761 | None | Code27 | 25 mm PVC dia drain piping with supports for AHUs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 625.4 | 625.4 | 100.0 | False | None | None | False | None | False | 62540.0 | 0 | 2958239 | 97761 | None | Code28 | SUPPLY ERECTION TESTING & COMISSIONING Ele.controll panel inter lock with AHUs and 5.5 TR 2 nos condenser unit with TEMP. & RH Controller
For AHU ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 12272.0 | 12272.0 | 2.0 | False | None | None | False | None | False | 24544.0 | 0 | 2958240 | 97761 | None | Code29 | SUPPLY ERECTION TESTING & COMISSIONING 4 Kw Ele. Heater with RH controller to controll humidity of 50 to 60% ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 66788.0 | 66788.0 | 2.0 | False | None | None | False | None | False | 133576.0 | 0 | 2958241 | 97761 | None | Code30 | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP -4C X 6 Sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 218.3 | 218.3 | 120.0 | False | None | None | False | None | False | 26196.0 | 0 | 2958242 | 97761 | None | Code31 | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP -4C X 4 Sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 177.0 | 177.0 | 120.0 | False | None | None | False | None | False | 21240.0 | 0 | 2958243 | 97761 | None | Code32 | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP -4C X 2.5 Sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 123.9 | 123.9 | 60.0 | False | None | None | False | None | False | 7434.0 | 0 | 2958244 | 97761 | None | Code33 | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP -8C X 2.5 Sqmm S.R. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 348.1 | 348.1 | 60.0 | False | None | None | False | None | False | 20886.0 | 0 | 2958245 | 97761 | None | Code34 | Supplying and drawing flexble multicore cable manufactured with electroytic grade copper with flexible copper conductor confirming to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 & confirming to GTP -4C X 10 Sqmm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 348.1 | 348.1 | 60.0 | False | None | None | False | None | False | 20886.0 | 0 | 2958246 | 97761 | None | Code35 | SUPPLY & Fixing Cable trey - 300 width x 50 ht perforated P. No.63 Item No.7.19.2 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 645.46 | 645.46 | 60.0 | False | None | None | False | None | False | 38727.6 | 0 | 2958247 | 97761 | None | Code36 | Plate COpper Earthing strip 24 x 3 mm connected to existing earthing P.55 Item No.7.3.6 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 617.14 | 617.14 | 100.0 | False | None | None | False | None | False | 61714.0 | 0 | 2958248 | 97761 | None | Code37 | SUPPLY & FIXING DP Gauge range 0 to 6 mm wg for OT room to monitoring positive pressure ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10089.0 | 10089.0 | 2.0 | False | None | None | False | None | False | 20178.0 | 0 | 2958249 | 97761 | None | Code38 | DSUPPLY & FIXING DP Gauge range 0 to 50 mm wg for AHU & EAU pre & fine filter section to monitoring pressure drop in the filters ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9735.0 | 9735.0 | 4.0 | False | None | None | False | None | False | 38940.0 | 0 | 2958250 | 97761 | None | Code39 | Supplying & Fixing Single Arm Rotating OT Pendant: Single ARM 320 Deg Rotating Anesthesia Pendant Complete with Electrical Outlets (8 Nos), Data Points (1 Nos) and Medical Gas Outlets (7 Nos), 1 Monitor Tray, 2 Nos. Shelfs, 2 Nos I V StandNote: 2 SET of DOCUMENTS & VALIDATION AT REST AS PER ISO-14644 and NABH standard to be submitted Design Qualification, Installation Qualification, Operational Qualification, Performance QualificationAir velocity testAir changes testAir qty.check testTemp. & RH testDOP test for Hepa filterPartical count test (Class 100, ISO - 5in the termial )Air flow pattern testRecovery testMajot materil test certificates ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 194700.0 | 194700.0 | 2.0 | False | None | None | False | None | False | 389400.0 | 0 | 2958251 | 97761 | None | Code40 | Supply , installation, testing and commissioning Double arm moveable pendant for surgeon with connected accessories.
The Pendants shall comply with NFPA 99C/HTM 02-01/DIN/EN/ISO 7396-1 as amended up to the last date of receipt of tenders. The support arms shall be extremely robust and revolve on high quality bearings, so that the pendant head glides smoothly and quickly to any desired position.
Double moveable arms (any combination) with total coverage of min 1800 mm and minimum 330 Each arm shall have ability of horizontal movement. Vertical movement shall be motorized and the arm height shall remain at a height greater than 6.5 feet above floor level.
Weight carrying capacity of the arm shall not be less than 180 kg. It shall have electromagnetic/pneumatic brakes.
Each arm shall be capable of minimum 330 of rotation, which can be easily adjusted to suit the desired mode of operation.
The pendant shall be European CE Certified with 4 digit notified body number/US FDA/ETL/UL/BIS certified/listed under medical devices directive.
The Pendant Service Heads shall be modular with minimum 800mm head.The heads shall be capable of accepting a range of shelves, infusion poles, electrical switch/sockers, gas outlets and other required accessories. The Pendant Heads shall support the range of Physiological Monitor Mounting Solutions.
The Pendant Service Heads shall be supplied with medical gas terminal units and 5A/15A or 6A/16 A hybrid sockets.
Pendant shall be supplied with outlets and probes as mentioned below.
Oxygen Outlets -2 nos , Medical Air Outlets 4 bar -1 no,Vacuum Outlets -2 nos
,Air(7bar) outlets-01 no, CO2 outlets-01 nos, Electrical Sockets-10 no, Adjustable shelf with two rails one on each side -3 no, Data socket RJ-45 -2 nos, IV Fluid Pole with 2 hooks -1 no, (Pole shall be capable of stacking 4 syringe pumps), Nitrous oxide outlets-1 no.
Pendent shall provide cut-outs for patch panel in integrated OTs (only for integrated OTs.)
Surgeon pendant shall have NIST connection for all gases to conncet the MGPLS system. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 430700.0 | 430700.0 | 2.0 | False | None | None | False | None | False | 861400.0 | 0 | 2958252 | 97761 | None | Code41 | Scrub Station
MOT SCRUB STATION (minimum size 1500 mm)
supply , installation and commissioning of compact surgical scrub sink shall be designed for use in OT area for pre-procedural scrub. Double sink combination shall be provided. Fabricated from heavy gauge type 304 stainless steel (minimum thicknes 1.5 mm) and shall be of seamless welded construction, polished to a satin finish.With a front access panel which shall be easily removable for access to the water controlled valve, waste connections, stoppers and strainers. Hands free operation shall include infra-red sensors with programmable adjustment. .Thermostatic mixing, valve control shall be located behind the access panel and it shall maintain constant water temperature.Timing shall be adjustable to meet individual application requiements.(built in with timer setting from 1 to 10 mic)It shall be provided with infrared sensors, thermostatic control taps with fail safe temprerature controls. All units shall have reduced anti-splash fronts.Knee/foot operated switch shall be provided additionally with all connected accessories. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 278480.0 | 278480.0 | 2.0 | False | None | None | False | None | False | 556960.0 | 0 | 2958253 | 97761 | None | Code42 | Supply , installation, testing and commissioning OT surgical Lighting system with connected accessroies
MOT surgical lighting system shall provide an ideal combination of brightness, manoeuvrability and shadow resolution without sacrificing colour and accuracy through a consistent LED technology.
Such lighting system shall have the following technical specifications:
a) Number of light heads : Two
b) Rotation system : 360
c) Colour temperature range : 3800 K to 5000 K (+/-10%)-variable colour temperature.
d) CRI : 93 Ra.
e) LEDs : Low temp . 3 Colours combination.
f) LED bulb life : 50,000 hrs.
g) Field size diameter : 20 to 28 cm (+/-10%)
h) Working range : 750 to 1100 mm (+/-10%)
i) Focus : Adjustable 100mm-250mm.
j) Illumination leve l: minimum 160,000 lux (both for major dome and minor dome separately).
k) Controls : control panel ( two:one on the wall and other on dome/ digital with wireless remote).
l) Power supply : 220 V/ 50Hz AC. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 413118.0 | 413118.0 | 2.0 | False | None | None | False | None | False | 826236.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Lift (20 passenger cum bed lift) | 16055739.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958254 | 97762 | None | code01 | Design, supplying, erecting testing and commissioning of - 20 Passenger/ Bed-cum-passenger hospital lift(5 stops/5 Opening) with speed of 1.0 mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4049282.65 | 4049282.65 | 2.0 | False | None | None | False | None | False | 8098565.3 | 0 | 2958255 | 97762 | None | code02 | Design, supplying, erecting testing and commissioning of - 15 Passenger/ Bed-cum-passenger hospital lift(5 stops/5 Opening) with speed of 1.0 mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665/2016 ( with latest amendments) part/section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressure switch, manual change over for doors during emergency, ARD of 10 times with sufficient battery back up and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2652391.5 | 2652391.5 | 3.0 | False | None | None | False | None | False | 7957174.5 | 0 |
| 1709805443000 | 0 | None | None | Buildings | UPS system | 2448500.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958256 | 97763 | None | code01 | Supply, Installation Testing and commissioning of double convertsion, DSP Based, True on line 3 x30KVA Modular type UPS system with 415V +/- 15% V,50Hz,3Ph Input & 415V+/-1%, 50 Hz ,3Ph Output, With Output 0.9 PF, working on 16 Bit microprocessor Architecture,Isolation transformers, RS 232 ports, monitoring software , O/L, SC. protections & self diagnostic features, LCD Display Panel for Functions & all parameters, complying with IEC standards. Convertors, Invertors & Battery Charger shall utilize PWM technology with IGBT. Battery Back up time of 15 minutes back up on 90kva load with required VRLA SMF individual Battery bank System(65AH-32 Nos each Battery Bank) housed in suitable Cabinet /Rack, Static ByPass, complete with Internal wiring & all accessories to be provided. The System shall have in-built P.F.correction & shall ensure THD as per latest International standards. The efficiency of UPS shall be 96% or more. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2448500.0 | 2448500.0 | 1.0 | False | None | None | False | None | False | 2448500.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Telephone & Networking | 1907083.27 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958257 | 97764 | None | Code01 | RJ45/ I.O. outlet Cat 6 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 437.43 | 437.43 | 80.0 | False | None | None | False | None | False | 34994.4 | 0 | 2958258 | 97764 | None | Code02 | Telephone socket ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 202.49 | 202.49 | 50.0 | False | None | None | False | None | False | 10124.5 | 0 | 2958259 | 97764 | None | Code03 | Supplying and drawing UTP-CAT 6E LAN cable. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 49.32 | 49.32 | 6500.0 | False | None | None | False | None | False | 320580.0 | 0 | 2958260 | 97764 | None | Code04 | Supplying & Fixing of I/O Socket with back box Single I/O ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 636.02 | 636.02 | 80.0 | False | None | None | False | None | False | 50881.6 | 0 | 2958261 | 97764 | None | Code05 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 9U with 450mm depth ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11001.85 | 11001.85 | 8.0 | False | None | None | False | None | False | 88014.8 | 0 | 2958262 | 97764 | None | Code06 | Supplying & Fixing of switch mounting rack with power manager & Cable manager as per standard specification 24U with 650mm depth ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 40739.03 | 40739.03 | 1.0 | False | None | None | False | None | False | 40739.03 | 0 | 2958263 | 97764 | None | Code07 | Supplying fixing of Network Switches. 24 port 10/100/1000 Switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9624.67 | 9624.67 | 6.0 | False | None | None | False | None | False | 57748.02 | 0 | 2958264 | 97764 | None | Code08 | Supplying fixing of Network Switches. 16 port 10/100/1000 Switch ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 8359.12 | 8359.12 | 10.0 | False | None | None | False | None | False | 83591.2 | 0 | 2958265 | 97764 | None | Code09 | Supplying & fixing of ..mtrs. Cat 6Patch Cable. 2Mtr ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 333.59 | 333.59 | 100.0 | False | None | None | False | None | False | 33359.0 | 0 | 2958266 | 97764 | None | Code10 | Supplying & Fixing of Patch panel for Lan Cabling. 16 Port 10/100 patch panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3958.9 | 3958.9 | 10.0 | False | None | None | False | None | False | 39589.0 | 0 | 2958267 | 97764 | None | Code11 | Supplying & Fixing of Patch panel for Lan Cabling. 24 Port 10/100 patch panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 10254.2 | 10254.2 | 6.0 | False | None | None | False | None | False | 61525.2 | 0 | 2958268 | 97764 | None | Code12 | Supplying and drawing PVC flexible 2 pair telepone unarmoured tinned copper cable. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 27.26 | 27.26 | 200.0 | False | None | None | False | None | False | 5452.0 | 0 | 2958269 | 97764 | None | Code13 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 20 Pair ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 497.13 | 497.13 | 4.0 | False | None | None | False | None | False | 1988.52 | 0 | 2958270 | 97764 | None | Code14 | EPABX:- Supply,Installation,Testing & Commissioning of micro-processor based, state of the Art, Telephone PBX System , IP READY,based on Linux/GRUB compliant, integrated Software for multiTasking for Hospitality Services including Billing ,comprising of items as below but not limited to them. Expanadable upto 50 Ports Providing PRI cards for Trunk lines / for tie line with reqd.software 16Analog Trunk Lines 4 Digital Extensions 20 Analogue Extensions( Expandable up to 50) In-Built Voicemail ( 4 Port & 80 Min) LAN Connectivity Embedded WELCOME MESSAGE Least Cost Routing Personal Assistant Music on Hold . ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 141600.0 | 141600.0 | 1.0 | False | None | None | False | None | False | 141600.0 | 0 | 2958271 | 97764 | None | Code15 | TELEPHONES Analog push button telephone with Caller ID, flash and radial ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2124.0 | 2124.0 | 50.0 | False | None | None | False | None | False | 106200.0 | 0 | 2958272 | 97764 | None | Code16 | Supply, Installation, Testing and Commissioning of 6-core OFC - Armoured outdoor cable (SM) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 115.64 | 115.64 | 400.0 | False | None | None | False | None | False | 46256.0 | 0 | 2958273 | 97764 | None | Code17 | Supplying heavy gauge PVC conduit pipe 25mm dia 2mm thick thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary(2/2) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 101.24 | 101.24 | 6000.0 | False | None | None | False | None | False | 607440.0 | 0 | 2958274 | 97764 | None | Code18 | 42 U Network cum Server Rack Assembly, Floor Mounting, made of Aluminium Channels equivalent to Euro Rack System with side and rear panels made of Powder Coated sheet steel, front transparent persplex door and with rails, rollers with fans will be provided at the top for ventilation. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 177000.0 | 177000.0 | 1.0 | False | None | None | False | None | False | 177000.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | CCTV System | 2891498.52 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958275 | 97765 | None | Code01 | IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8 2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 23836.0 | 23836.0 | 35.0 | False | None | None | False | None | False | 834260.0 | 0 | 2958276 | 97765 | None | Code02 | IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 25606.0 | 25606.0 | 8.0 | False | None | None | False | None | False | 204848.0 | 0 | 2958277 | 97765 | None | Code03 | IP PTZ CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 177000.0 | 177000.0 | 2.0 | False | None | None | False | None | False | 354000.0 | 0 | 2958278 | 97765 | None | Code04 | Supplying, installation, testing and commissioning of complete 32 channel 4K embedded network video recorder,up to 12MP(4K) resolution live view,preview,and play back,full POE Support (for up to 16 channels),internal storage supports 8HDDs expandable up to 64TB (8TB each),operating temperatures(-10 degree C) and (55 degree C),UL,CE,FCC. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 271400.0 | 271400.0 | 1.0 | False | None | None | False | None | False | 271400.0 | 0 | 2958279 | 97765 | None | Code05 | Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as required ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 17110.0 | 17110.0 | 16.0 | False | None | None | False | None | False | 273760.0 | 0 | 2958280 | 97765 | None | Code06 | Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as required ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 47495.0 | 47495.0 | 4.0 | False | None | None | False | None | False | 189980.0 | 0 | 2958281 | 97765 | None | Code07 | Supply and Installation of I/Os ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 147.5 | 147.5 | 180.0 | False | None | None | False | None | False | 26550.0 | 0 | 2958282 | 97765 | None | Code08 | Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as required ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 265.5 | 265.5 | 50.0 | False | None | None | False | None | False | 13275.0 | 0 | 2958283 | 97765 | None | Code09 | Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as required ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 336.3 | 336.3 | 50.0 | False | None | None | False | None | False | 16815.0 | 0 | 2958284 | 97765 | None | Code10 | Supply and Installation of 6 Core Single Mode Ofc Cable The rate shall include all mounting accessories complete as required ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 115.64 | 115.64 | 250.0 | False | None | None | False | None | False | 28910.0 | 0 | 2958285 | 97765 | None | Code11 | Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as required ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 70800.0 | 70800.0 | 2.0 | False | None | None | False | None | False | 141600.0 | 0 | 2958286 | 97765 | None | Code12 | Supplying and drawing UTP-CAT 6E LAN cable ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 49.32 | 49.32 | 3350.0 | False | None | None | False | None | False | 165222.0 | 0 | 2958287 | 97765 | None | Code13 | Supplying heavy gauge PVC Consealed conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 101.24 | 101.24 | 3000.0 | False | None | None | False | None | False | 303720.0 | 0 | 2958288 | 97765 | None | Code14 | Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5321.8 | 5321.8 | 4.0 | False | None | None | False | None | False | 21287.2 | 0 | 2958289 | 97765 | None | Code15 | Supplying & Fixing of switch mounting rack with power manager & Cable manager 12U with 450mm depth ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 11467.83 | 11467.83 | 4.0 | False | None | None | False | None | False | 45871.32 | 0 |
| 1709805443000 | 0 | None | None | Buildings | TV System | 36904.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958290 | 97766 | None | Code01 | TV socket ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 202.49 | 202.49 | 10.0 | False | None | None | False | None | False | 2024.9 | 0 | 2958291 | 97766 | None | Code02 | The Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor.Booster amplifier. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3540.0 | 3540.0 | 3.0 | False | None | None | False | None | False | 10620.0 | 0 | 2958292 | 97766 | None | Code03 | The Scope of work is Supply,istallation, Testing for T.V. System with following Items & components in Rooms & other Specific Areas. It also covers co-ordination with T.V service provider for completeness & usage of the Items /components erected by Vendor. 3 way splitter. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | 2958293 | 97766 | None | Code04 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 57.11 | 57.11 | 400.0 | False | None | None | False | None | False | 22844.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Nurse Call system | 2072034.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958294 | 97767 | None | Code01 | Supply, installation, testing and commissioning of 'The Bedside call unit shall be mounted on the head boards where there are patient headboards or on the walls where it can be implemented within the system.'The Bedside call unit shall be 2 input\output ports for RJ45 Endings for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. 'On the standard bedside call unit front side there shall be: 'An "End Call" Button with a green tick mark symbol.'Reassurance backlight in order to give visual information about call ststus.'Continous backlight for easy visibility of the unit at night.'Pressing on the end call button ends the call and turns the assigned overdoor light to green. IP System controller logs the event as "Presence"'Pressing the end call button for the second time ends the "presence" and turns off the assigned overdoor light.'The Bedside Call Unit shall made from noninflammable PC-ABS-FR Materials.'It can be used individually as a call button where patient handset is not needed. Other wise, its connection with the patient handset shall be easily established ny the connecting via RJ45 on its front side.'A Nurse call shall be initated via the patient handset or the bedside call unit. These two buttons shall be accepted by the system as equivalent. In the event that these buttons are pressed.'If the unit is ablee to transmit the call to the zone controller, the LED on the unit shall flash with 1.0 second intervals, call transmission information shall be audibly notified to the patient.'If there is an error in the call transmission, a continuous red light showing error status shall only stop when the call termination button is pressed, subsequent presses of the button shall trigger an audio alert each time.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4130.0 | 4130.0 | 65.0 | False | None | None | False | None | False | 268450.0 | 0 | 2958295 | 97767 | None | Code02 | Supply, installation, testing and commissioning of PATIENT HANDSET BASIC.This Handset will be used in the locations that are connected to the system by a zone controller.'It Shall be ergonomically suitable to be handheld.'It shall be connected to the bedside call unit with an independent cable.'on its front side there shall be 'A "start Call" Button with red nurse symbol.'Reassurance LED light in order to give visual information about the call status.Continues LED Light for easy visibility at night.'Call Initation and error notification procedures is the same as bedside call unit except audio alerts are always issued by the bedside call unit its call initiation button and back light works in parallel with the one on the bedside call unit.It shall have an easily cleanable surface that dose not promote bacterial growth.Patient handset shall be made from non inflammable PC-ABS-FR Materials. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 5900.0 | 5900.0 | 65.0 | False | None | None | False | None | False | 383500.0 | 0 | 2958296 | 97767 | None | Code03 | Supply, installation, testing and commissioning of CODE BLIE CALL UNIT;- The Code Blue Call Unit shall be mounted on headboards where there are patient headboards or on the walls where it can be implemented within the system. The Code Blue Call Unit has 2 Input/Output ports for RJ45 endings for cabling in a chain with Over Door Lights and other call units and eventually to one Zone Controller.
On the Code Blue call unit front side there shall be; A “start code blue” button with a blue medicine symbol. Pressing the button initiates a Code Blue event, turning on the assigned Overdoor lights to Blue. An “end code blue” button with a green tick mark symbol. Pressing the Button shall cancel the Code blue alarm turning the assigned Overdoor lights. Reassurance backlight in order to give visual information about the call status. Continuous backlight for easy visibility of the unit at night.
The Code Blue Call Unit shall be made from nonflammable PC-ABS-FR materials.
If the unit is able to transmit the call to the zone controller, the LED on the unit shall flash with 1.0-second intervals. Call transmission information shall be audibly notified to the patient.
If there is an error in call transmission, a continuous red light showing the error status shall only stop when the call termination button is pressed or room control connection is made. Subsequent presses of the button shall trigger an audio alert each time. Its connection shall be made with Cat 6 UTP cable and RJ45 of B standard. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4071.0 | 4071.0 | 65.0 | False | None | None | False | None | False | 264615.0 | 0 | 2958297 | 97767 | None | Code04 | Supply, installation, testing and commissioning of PULL-CORD CALL UNIT(WC\Bathroom)-The Pull-cord call unit has 2 input\output ports for RJ45 Ending for cabling in a chain with overdoor lights and other call units and eventually to one zone controller. on its front side there shall be A pull-code call unit with customizable length with minimum 1.5 meters to serve as a call-code.A call termination button (indicated by a green tick Mark Symbol).Its Connection shall be made with CAT6 UTP cable and RJ45 of B standard.A priority WC Emergency call shall start when the cord is pulled.This Device will be used in the locations that are connected to the system by a zone controller. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4189.0 | 4189.0 | 13.0 | False | None | None | False | None | False | 54457.0 | 0 | 2958298 | 97767 | None | Code05 | Supply, installation, testing and commissioning of 'Over Door Light shall use environmentally friendly LEDs.'It shall consist of Red, Green, Blue, white, Pink Colored Warning Light.'In Normal Condition, no light shall be lit, if the patient makes nurse call, Red Light shall be Lit with in 0.5 Seconds. After all nurse call, when the nurse presses the green presence button on the call unit, the light of the over door light will return green.'In code blue, the blue light shall be lit.'The outer casing of the over door light shall be made of nonflammble PC-ABS-FR Materials.'Over door light shall have 2 input\output ports for RJ45 ending for cabling in a chain with call units on one of the communication lines of the zone controller. Alternativley, it connects to the RCU in private & semi private rooms.'Its connection shall be made with cat 6 UTP Cable RJ45 of B Standard.'This device shall be powered by the Zone Controller or black colored communication ports of RCU unit to which it is connected. It shall not require additional energy supply. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 11463.7 | 11463.7 | 13.0 | False | None | None | False | None | False | 149028.1 | 0 | 2958299 | 97767 | None | Code06 | Supply, installation, testing and commissioning of 'IP BASED NURSE CALL SYSTEM Supply, Installation, testing and commissioning of the IP based Nurse Call System based on the following components including but not restricted to gold plated connecting leads, connectors, patch cables, jumpers, nuts, screws, bolts, mounting plates, cover plates, back boxes etc., 'Shall be in accordance with International guidelines and shall be in such a way that the most effective communication between Patient, Nursing Staff, Doctor & management staff can be provided in the least possible time. 'System Operation\Ward Nurse Station;-'The ward Nurse Station Shall be used in the location that are connected to the system by a zone controller. It is placed in each multi bed ward areas at the nurse station overlooking the patent beds.'The ward Nurse station Shall have a minimum 10 Inch touchscreen and include its own integrated handsfree voice communication with other Nurse control Panels.'The Nurse control panel may be used to monitor the status of every assigned call points, call and alarm status.the screen will show active calls and emergency code with top to bottom priority, highest priority active calls is on top and longest awaiting calls within same call type having more priority than same type.'The origin room and the bed information of all active nurse calls, code blue calls shall be shown with an audiovisual alert along with the call type.'onscreen call points shall have notification of relevant icons, colors, and tones according to their call status as well as time the call started and time passed since.'call shall be shown real time. Each activity will be send to IP System Controller for logging enabling later inspection and reporting.'Time stamp and error logs for situations when the energy supply of the panel is cut or there is no network connection shall be recorded on the IP System controller.'Emergency codeblue, Red, pink, and white shall be initiated from the touch screen. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 95138.68 | 95138.68 | 3.0 | False | None | None | False | None | False | 285416.04 | 0 | 2958300 | 97767 | None | Code07 | Supply, installation, testing and commissioning of IP ZONE CONTROLLER This is the main node device used to network the Nurse call system devices to each other for areas are not private or semi-private rooms and do not have item 3.2(RCU). It is to be used for multi bed wards areas in a single open soace with a nurse desk overlooking the assigned patient beds.Each zone controller has 2 communication ports which support chains of up to 24 calls initiation devices each,and up to as many over door lights as the number of the call initiation devices, for a total maximum support of 48 call devices.The connection shall be made with cat 6 UTP Cable and RJ45 of B Standard. Toatl cable length from the Zone Controller to the last call device Cannot be longer than 500 meters for each communication line oneach communication port.Zone controller shall have 2 power injectors to be included with the device to be used for injecting 12V power to be used on each communication line. Each power injector has 2 RJ% Ports to be connected at suitable location to prevent voltage drops on the lines.Each Power injector require 110-240 V Power.There shall not be any limits to the number of zone controllers that can be used in a nurse call system, they may be placed in the network switch, its connection shall be made with cat 6 UTP cable and RJ% of B Standard.The zone controller shall have 1 port for 110-240 V Power.'The zone controller must be configurable from the IP System Controller. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 85388.34 | 85388.34 | 3.0 | False | None | None | False | None | False | 256165.02 | 0 | 2958301 | 97767 | None | Code08 | Supplying and drawing UTP-CAT 6E LAN cable ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 49.32 | 49.32 | 4000.0 | False | None | None | False | None | False | 197280.0 | 0 | 2958302 | 97767 | None | Code09 | Supplying heavy gauge PVC Consealed conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thick ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 101.24 | 101.24 | 2000.0 | False | None | None | False | None | False | 202480.0 | 0 | 2958303 | 97767 | None | Code10 | Supplying & Fixing of Patch panel for LAN cabling .24 Port 10/100 patch panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5321.8 | 5321.8 | 2.0 | False | None | None | False | None | False | 10643.6 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Furniture work cost | 11998435.88 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958304 | 97768 | None | Code01 | Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification.GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 11493.2 | 11493.2 | 126.14 | False | None | None | False | None | False | 1449752.248 | 0 | 2958305 | 97768 | None | Code02 | Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification - FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 11493.2 | 11493.2 | 198.95 | False | None | None | False | None | False | 2286572.14 | 0 | 2958306 | 97768 | None | Code03 | Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification-SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 11493.2 | 11493.2 | 198.95 | False | None | None | False | None | False | 2286572.14 | 0 | 2958307 | 97768 | None | Code04 | Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally & Externally finish, shelves shall be formed out of 19mm ply finished with 1.5mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification-THIRD FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 11493.2 | 11493.2 | 89.36 | False | None | None | False | None | False | 1027032.352 | 0 | 2958308 | 97768 | None | Code05 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. Ground Floor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 41654.0 | 41654.0 | 3.0 | False | None | None | False | None | False | 124962.0 | 0 | 2958309 | 97768 | None | Code06 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 41654.0 | 41654.0 | 6.0 | False | None | None | False | None | False | 249924.0 | 0 | 2958310 | 97768 | None | Code07 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 41654.0 | 41654.0 | 6.0 | False | None | None | False | None | False | 249924.0 | 0 | 2958311 | 97768 | None | Code08 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. Table 2400 mm x 900 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - THIRD FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 41654.0 | 41654.0 | 3.0 | False | None | None | False | None | False | 124962.0 | 0 | 2958312 | 97768 | None | Code09 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 31270.0 | 31270.0 | 7.0 | False | None | None | False | None | False | 218890.0 | 0 | 2958313 | 97768 | None | Code10 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 31270.0 | 31270.0 | 18.0 | False | None | None | False | None | False | 562860.0 | 0 | 2958314 | 97768 | None | Code11 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 31270.0 | 31270.0 | 8.0 | False | None | None | False | None | False | 250160.0 | 0 | 2958315 | 97768 | None | Code12 | Table : Providing and fixing Executive tables of different sizes with 19 mm waterproof plywood frame work laminated on all the exposed surface with 1 mm thick laminate and a key board tray is provided and all edges of the plywood is lipped with 19mm x 6mm teak/beach wood lipping and the edge of the table top is lipped with 32 mm x 19 mm teak/beach wood lipping. The item to include a side cabinet with 19 mm thick waterproof plywood framework, shelves and shutters laminated on all the exposed surface with 1mm thick laminate and inside surface is also laminate with 0.8 mm laminate. The item to include all hardware like stainless steel hinges, drawer sliders, Euro multipurpose locks, brush steel handles, magnetic catch, all hardware complete and all the teak/beach wood beading is polished. - Table 2100 mm x 750 mm x 750 mm ht, Side Table 1100 mm x 450 mm x 750 mm ht. - THIRD FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 31270.0 | 31270.0 | 6.0 | False | None | None | False | None | False | 187620.0 | 0 | 2958316 | 97768 | None | Code13 | Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. - GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 27730.0 | 27730.0 | 1.0 | False | None | None | False | None | False | 27730.0 | 0 | 2958317 | 97768 | None | Code14 | Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. - FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 27730.0 | 27730.0 | 4.0 | False | None | None | False | None | False | 110920.0 | 0 | 2958318 | 97768 | None | Code15 | Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge.-SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 27730.0 | 27730.0 | 4.0 | False | None | None | False | None | False | 110920.0 | 0 | 2958319 | 97768 | None | Code16 | Providing and fixing Main table 1500x750x735mm, table top 25mm thick PLPB 1000x450x735mm, 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK Main and Side tables BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTH SIDES. EDGE SEALED WITH 2MM THICK PVC BEADING 25 MM THICK PLAIN PARTICLE BOARD (PPB) CLAD WITH 0.6MMTHICK POST FORMED LAMINATE AND 1MM THICK BACKINGLAMINATE (BDL). FLAT EDGE DULY SEALED WITH 2MM THICKPVC BEADING.18MM THICK PLAIN PARTICLE BOARD (PPB)CLAD WITH 1.0MM THICK DECORATIVE LAMINATE (DL) ON BOTHSIDES. EDGE SEALED WITH 2MM THICK PVC BEADING. etc. as per approved drawing and directed by the engineer in charge. - THIRD FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 27730.0 | 27730.0 | 2.0 | False | None | None | False | None | False | 55460.0 | 0 | 2958320 | 97768 | None | Code17 | Single seater sofa Teakwood Sofa Chair Size : 900 x 750 x 800 Providing and supplying fully upholstered single seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality) on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs. 454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12980.0 | 12980.0 | 2.0 | False | None | None | False | None | False | 25960.0 | 0 | 2958321 | 97768 | None | Code18 | Single seater sofa Teakwood Sofa Chair Size : 900 x 750 x 800 Providing and supplying fully upholstered single seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality) on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs. 454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge. -GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12980.0 | 12980.0 | 2.0 | False | None | None | False | None | False | 25960.0 | 0 | 2958322 | 97768 | None | Code19 | Single seater sofa Teakwood Sofa Chair Size : 900 x 750 x 800 Providing and supplying fully upholstered single seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality) on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs. 454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge.-FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12980.0 | 12980.0 | 1.0 | False | None | None | False | None | False | 12980.0 | 0 | 2958323 | 97768 | None | Code20 | Single seater sofa Teakwood Sofa Chair Size : 900 x 750 x 800 Providing and supplying fully upholstered single seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality) on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs. 454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge.-SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12980.0 | 12980.0 | 1.0 | False | None | None | False | None | False | 12980.0 | 0 | 2958324 | 97768 | None | Code21 | Two Seater Teakwood Sofa 1350 x 650 x 800 Providing and supplying fully upholstered Two seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs.454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge.-FIRST FOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 20060.0 | 20060.0 | 2.0 | False | None | None | False | None | False | 40120.0 | 0 | 2958325 | 97768 | None | Code22 | Two Seater Teakwood Sofa 1350 x 650 x 800 Providing and supplying fully upholstered Two seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs.454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge.-FIRST FOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 20060.0 | 20060.0 | 2.0 | False | None | None | False | None | False | 40120.0 | 0 | 2958326 | 97768 | None | Code23 | Two Seater Teakwood Sofa 1350 x 650 x 800 Providing and supplying fully upholstered Two seater sofa with arm rest. Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF for necessary covering to back and arm rest sides. Provision of 100mm thick foam rubber of ISI grade reputed make for seat fixed on elastic springs / navar and 75mm thick foam rubber for back rest with 25mm foam rubber for arm rest. With 12mm foam rubber slab for edge binding. Fixing 25mm thick PU foam to seat and back for additional padding. Covering of gray cloth ( thick quality on entire sofa seat, back, arm rest. Fixing good quality tapestry as per approved shade and design of basic price not less than Rs.454/- per meter (including VAT) Complete with including , materials, labours, taxes, leads lifts and as per directed by Engineer-In-Charge.-SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 20060.0 | 20060.0 | 1.0 | False | None | None | False | None | False | 20060.0 | 0 | 2958327 | 97768 | None | Code24 | SOFA - 3 SEATER Teakwood Sofa Providing and supplying and placing Three Seater sofa of over all size 1800 x 750 x 750 Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF of requisite manufacturer for necessary covering from back and arm rests. The seat shall be 125mm and back shall be of 100mm thick duly covered with tepastory fabric of Rs. 454/- ( Including tax ) per meter including necessary Hardware, Navar, Jute cloth, casement, springs etc. including all leads, lifts, taxes and HOM machineries etc complete as per Architect design and as directed by Engineer-In-charge- Ground floor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 28910.0 | 28910.0 | 2.0 | False | None | None | False | None | False | 57820.0 | 0 | 2958328 | 97768 | None | Code25 | SOFA - 3 SEATER Teakwood Sofa Providing and supplying and placing Three Seater sofa of over all size 1800 x 750 x 750 Structure to be made of teakwood arm rest of size 100x38x750mm and silverwood frame of 100mmx38mm and 75mm x 38mm size along with 6mm MDF of requisite manufacturer for necessary covering from back and arm rests. The seat shall be 125mm and back shall be of 100mm thick duly covered with tepastory fabric of Rs. 454/- ( Including tax ) per meter including necessary Hardware, Navar, Jute cloth, casement, springs etc. including all leads, lifts, taxes and HOM machineries etc complete as per Architect design and as directed by Engineer-In-charge-FIRST FOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 28910.0 | 28910.0 | 1.0 | False | None | None | False | None | False | 28910.0 | 0 | 2958329 | 97768 | None | Code26 | Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (Hassan Approved Rate)-GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 42480.0 | 42480.0 | 4.0 | False | None | None | False | None | False | 169920.0 | 0 | 2958330 | 97768 | None | Code27 | Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (Hassan Approved Rate)-FIRST FOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 42480.0 | 42480.0 | 4.0 | False | None | None | False | None | False | 169920.0 | 0 | 2958331 | 97768 | None | Code28 | Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (Hassan Approved Rate)-SECOND FOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 42480.0 | 42480.0 | 4.0 | False | None | None | False | None | False | 169920.0 | 0 | 2958332 | 97768 | None | Code29 | Providing and fixing of Three Seater Stainless Steel Waiting Chair complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. (Hassan Approved Rate)-THIRD FOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 42480.0 | 42480.0 | 2.0 | False | None | None | False | None | False | 84960.0 | 0 | 2958333 | 97768 | None | Code30 | Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. -Ground floor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 19470.0 | 19470.0 | 13.0 | False | None | None | False | None | False | 253110.0 | 0 | 2958334 | 97768 | None | Code31 | Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. -FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 19470.0 | 19470.0 | 19.0 | False | None | None | False | None | False | 369930.0 | 0 | 2958335 | 97768 | None | Code32 | Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. -SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 19470.0 | 19470.0 | 7.0 | False | None | None | False | None | False | 136290.0 | 0 | 2958336 | 97768 | None | Code33 | Optima Chairs with High Back with mesh and lumber support SEAT/BACK ASSEMBLY: The Cushioned seat assembly consists of seat outer (material-30% Glass Fiber Filled Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyester fabric. The Net Back is made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) upholstered with polyester Mesh fabric. FULL BACK SIZE: 46.5 cm. (W) x 60.0 cm. (H) SEAT SIZE : 51.0 cm. (W) x 49.0 cm. (D) POLYURETHANE FOAM: The Polyurethane foam is moulded with density = 45 +/- 2 kg/m , ) ARMRESTS : The armrest is having two adjustment, Height and Depth. Height adjustment is provided in Aluminum structure of armrest which is connected to Aluminum Back spine And is operated by button. The depth adjustment is provided in pad which is fixed to armrest structure. Armrest Top is made up of PU molded over plastic inner. LUMBAR SUPPORT ASSEMBLY: The Lumbar suport assembly consists of lumbar spine (material-Glass Fiber Filled Nylon) which is fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) is fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 50mm. Neck-rest ASSEMBLY: The Neck-rest assembly consists of upholstered Neck-rest inner (material- Poly Propylene) etc., complete as per the direction of Engineer in charge of the work. -THIRD FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 19470.0 | 19470.0 | 6.0 | False | None | None | False | None | False | 116820.0 | 0 | 2958337 | 97768 | None | Code34 | STAFF CHAIRS : Supplying HIGH BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval- GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 7316.0 | 7316.0 | 14.0 | False | None | None | False | None | False | 102424.0 | 0 | 2958338 | 97768 | None | Code35 | STAFF CHAIRS : Supplying HIGH BACK Chair Blue mango with contact crome flex back chair with co-active synchro, gas lift, revolving, tilting, and height adjustable fully cushioned medium back chairs and two way adjustable arms. prior confirmation shall be obtain from the officer / Architect for approval--FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 7316.0 | 7316.0 | 27.0 | False | None | None | False | None | False | 197532.0 | 0 | 2958339 | 97768 | None | Code36 | Providing and fixing Centre Teapoy of size of 900 x 600mm oval shape as per principal chief architecht dwg no 120816/16 made out of good quality Burma Teak wood legs of cross section 50 x 10 mm and side bars of 50 x 60mm with 12mm thick modi guard glass top wtih edge grainding on polishing of oval shape of 900 x 600mm as per dwg. Polished with melamine finish in spray with necessary compressor Complete with all materials, labour, leads lifts etc and directed by Engineer in charge - GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10856.0 | 10856.0 | 2.0 | False | None | None | False | None | False | 21712.0 | 0 | 2958340 | 97768 | None | Code37 | Providing and fixing Centre Teapoy of size of 900 x 600mm oval shape as per principal chief architecht dwg no 120816/16 made out of good quality Burma Teak wood legs of cross section 50 x 10 mm and side bars of 50 x 60mm with 12mm thick modi guard glass top wtih edge grainding on polishing of oval shape of 900 x 600mm as per dwg. Polished with melamine finish in spray with necessary compressor Complete with all materials, labour, leads lifts etc and directed by Engineer in charge - FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10856.0 | 10856.0 | 2.0 | False | None | None | False | None | False | 21712.0 | 0 | 2958341 | 97768 | None | Code38 | Providing and fixing Key Board Tray plastic oridnary Tray is made of ABS in approved color and texture. (Size: 570 (W) x275 (D) x 38 (H) MM. 350 mm (Long) x 11.8 mm (Thk) Single extension (Stroke: 230 mm)Ball-slide Made of combination of 1.2/1.5 mm thk roll-formed CRCASteel sheet. Retrofit mouse tray is provided which could be fitted at right hand or lefthand as per user requirement. Mouse tray is made of ABS in approvedcolor and texture. Mouse Tray Size is 450 (L) x 198 (D) x 15 (H) MM. complete including cost and conveyance of all materials, labour for all items of work, as per the dirctions of the Engineer in charge of the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1416.0 | 1416.0 | 15.0 | False | None | None | False | None | False | 21240.0 | 0 | 2958342 | 97768 | None | Code39 | Providing and fixing CPU Trolly is made of 1.0 mm thick MS CRCA Sheet and Side support is madeof 0.8 mm thick MS CRCA Sheet.Lockable/Non-lockable twin wheel castors are injection molded in BlackNylon.as per the dirctions of the Engineer in charge of the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 885.0 | 885.0 | 15.0 | False | None | None | False | None | False | 13275.0 | 0 | 2958343 | 97768 | None | Code40 | DRINKING WATER COOLER : Providing and installing water cooler ss body and ss tank with specification Storage Capacity 80 Ltr, Normal cooling capacity 40Ltr, No of Faucets 2nos, Dimensions (MM) 665W x 480 D x 1210H, weight 47kg, Glasses Per hr 200Ltr, Refrigerant R-134a, current (amps)2.50, water over flow 1/2BSP, Typer of Compresser REIP. Including UV Corbon & Sediment filter of 250L PH water Purifier Fixing Seperatly duly connect. The rate to includ of water piping From OHT To Necessary drainage system for out let, angle cock system for as per specification. (GROUND FLOOR) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 47200.0 | 47200.0 | 4.0 | False | None | None | False | None | False | 188800.0 | 0 | 2958344 | 97768 | None | Code41 | PROVIDING ALL SAFE OFFICE LOCKER STEEL ALMIRAH (900X1800X600). depth with 5 shelves of 14 gauge powder coated the rate including one locker ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 11564.0 | 11564.0 | 6.0 | False | None | None | False | None | False | 69384.0 | 0 | 2958345 | 97768 | None | Code42 | Providing and fixing 450mmw x 450 mmd x 685 mmht) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge.-GROUND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4956.0 | 4956.0 | 16.0 | False | None | None | False | None | False | 79296.0 | 0 | 2958346 | 97768 | None | Code43 | Providing and fixing 450mmw x 450 mmd x 685 mmht) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge.-FIRST FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4956.0 | 4956.0 | 18.0 | False | None | None | False | None | False | 89208.0 | 0 | 2958347 | 97768 | None | Code44 | Providing and fixing 450mmw x 450 mmd x 685 mmht) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge.-SECOND FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4956.0 | 4956.0 | 17.0 | False | None | None | False | None | False | 84252.0 | 0 | 2958348 | 97768 | None | Code45 | Providing and fixing 450mmw x 450 mmd x 685 mmht) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock, etc., complete as per specifications, drawings and as directed by Engineer in charge.-THIRD FLOOR ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4956.0 | 4956.0 | 10.0 | False | None | None | False | None | False | 49560.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | External Electrification | 4983796.79 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958349 | 97769 | None | Code01 | Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 9184.65 | 9184.65 | 2.0 | False | None | None | False | None | False | 18369.3 | 0 | 2958350 | 97769 | None | Code02 | Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 1444.67 | 1444.67 | 2.0 | False | None | None | False | None | False | 2889.34 | 0 | 2958351 | 97769 | None | Code03 | Supply of 11 kV, 45 KN Polymeric Insulator ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 112.93 | 112.93 | 6.0 | False | None | None | False | None | False | 677.58 | 0 | 2958352 | 97769 | None | Code04 | Erection of 11 kV, 45 KN Polymeric Insulator ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 62.3 | 62.3 | 6.0 | False | None | None | False | None | False | 373.8 | 0 | 2958353 | 97769 | None | Code05 | Supply of Spiral Earth Electrode ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 310.22 | 310.22 | 2.0 | False | None | None | False | None | False | 620.44 | 0 | 2958354 | 97769 | None | Code06 | Erection of Spiral Earth Electrode ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 120.71 | 120.71 | 2.0 | False | None | None | False | None | False | 241.42 | 0 | 2958355 | 97769 | None | Code07 | Supply and fixing of Caution/Danger Board ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 194.7 | 194.7 | 1.0 | False | None | None | False | None | False | 194.7 | 0 | 2958356 | 97769 | None | Code08 | Supply of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 115.52 | 115.52 | 2.0 | False | None | None | False | None | False | 231.04 | 0 | 2958357 | 97769 | None | Code09 | Erection of Anti Climbing Device (12 Mtr GI Barbed Wire ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 54.52 | 54.52 | 2.0 | False | None | None | False | None | False | 109.04 | 0 | 2958358 | 97769 | None | Code10 | Supply and fixing of 11 kV, 400 Amps Double Break GOS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 27595.48 | 27595.48 | 1.0 | False | None | None | False | None | False | 27595.48 | 0 | 2958359 | 97769 | None | Code11 | Supply and fixing of H-Frame for mounting GOS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 7880.16 | 7880.16 | 1.0 | False | None | None | False | None | False | 7880.16 | 0 | 2958360 | 97769 | None | Code12 | Supply of DOLO Cut Out ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 7625.75 | 7625.75 | 1.0 | False | None | None | False | None | False | 7625.75 | 0 | 2958361 | 97769 | None | Code13 | Erection of DOLO Cut Out ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 307.63 | 307.63 | 1.0 | False | None | None | False | None | False | 307.63 | 0 | 2958362 | 97769 | None | Code14 | Load Break Switch with Panel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 95064.22 | 95064.22 | 1.0 | False | None | None | False | None | False | 95064.22 | 0 | 2958363 | 97769 | None | Code15 | 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box
Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification
(Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 316026.66 | 316026.66 | 1.0 | False | None | None | False | None | False | 316026.66 | 0 | 2958364 | 97769 | None | Code16 | CT PT Operated ETV Meter 0.2s Accuracy Class with ABT feature and DLMS protocal with ToD with RS 232 PortUNIDIRACTIONAL (Used for HT Installation, LT
Metering Cubicle 50-150 KW ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 25460.27 | 25460.27 | 1.0 | False | None | None | False | None | False | 25460.27 | 0 | 2958365 | 97769 | None | Code17 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.65 | 0.65 | 390000.0 | False | None | None | False | None | False | 253500.0 | 0 | 2958366 | 97769 | None | Code18 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 3.0 | False | None | None | False | None | False | 2005.41 | 0 | 2958367 | 97769 | None | Code19 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 30.0 | False | None | None | False | None | False | 21611.7 | 0 | 2958368 | 97769 | None | Code20 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 30.0 | False | None | None | False | None | False | 36058.5 | 0 | 2958369 | 97769 | None | Code21 | 11kv, 630A Vaccum Circuit Breaker ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 354000.0 | 354000.0 | 3.0 | False | None | None | False | None | False | 1062000.0 | 0 | 2958370 | 97769 | None | Code22 | Supply, installation, testing and commissioning of 500 kVA , 11kV/433V, 3 phase, 50 Hz, Delta star, DYn11 , outdoor, natually cooled, Oil Immersed copper double wound transformer Conforming to IS: 1180- 1180- 3 LEVEL Contained in mild steel radiator Cooled tank with first fill of oil as per IS: 335 with On load tap changer from +5% to -15% in steps of +/-1.25%, remote tap changes panel with AVR, class F insulation, Rating and Diagram Plate, Earthing Terminals - 2 Nos,Liffting Lugs,Air release hole with plug,Dehydrating Silica Gel Breather,Prismatic Oil level Guage,Oil Conservator with drain plug,Thermometer pocket,Jacking Lugs,Bottom drain cum filter valve,Top filter valve,4 Nos. Bi-Directional rollers,Pressure relief device,Marshalling Box [wherever applicable],100 mm OTI/ 150 mm OTI with alarm & trip,WTI with alarm and trip,Buchholz Relay with alarm and trip,Shut off valves for Buchholz Relay,Magnetic Oil Level guage,Radiators - Fixed / Detachable With HT & LT Cable end boxes / Provison for LV Bus Duct type, The transformer shall have suitable enclosure for providing neutral CT on earthed star point with connector for connection to REF relay provided in Main panel. All routing test as per IS shall be conducted on the transformer. The Transformer Enclosure shall have suitably designed Louvers for Air Circulation & efficient Cooling, required Danger boards, signages, lettering etc.. The enclosure shall be Epoxy Powder coated. The transformer shall be subjected to all routine tests as per IS/IEC standards. Type test certificate shall be submitted (As Per EC BC Norms) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 433989.84 | 433989.84 | 2.0 | False | None | None | False | None | False | 867979.68 | 0 | 2958371 | 97769 | None | Code23 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40 mm dia 2.90 mm thick GI pipe 2.5m long buried in a pit . The pit should be
filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washers and check nuts
etc., the pipe shall have 16 through holes of 12 mm dia ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 4555.98 | 4555.98 | 16.0 | False | None | None | False | None | False | 72895.68 | 0 | 2958372 | 97769 | None | Code24 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 166.14 | 166.14 | 150.0 | False | None | None | False | None | False | 24921.0 | 0 | 2958373 | 97769 | None | Code25 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 40x6mm Copper strip ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 2132.61 | 2132.61 | 150.0 | False | None | None | False | None | False | 319891.5 | 0 | 2958374 | 97769 | None | Code26 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm Copper plate ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 9632.46 | 9632.46 | 16.0 | False | None | None | False | None | False | 154119.36 | 0 | 2958375 | 97769 | None | Code27 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 5278.97 | 5278.97 | 4.0 | False | None | None | False | None | False | 21115.88 | 0 | 2958376 | 97769 | None | Code28 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Indoor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 4073.12 | 4073.12 | 3.0 | False | None | None | False | None | False | 12219.36 | 0 | 2958377 | 97769 | None | Code29 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x95Sqmm.Outdoor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 6902.76 | 6902.76 | 3.0 | False | None | None | False | None | False | 20708.28 | 0 | 2958378 | 97769 | None | Code30 | Supply & Making of 11KV (E) Extruded "X" linked for tubing & moulded & cross-linked components using Heat Shrink Stress Control tube having High Permittivity XLPE Terminations - INDOOR & OUTDOOR JOINTING KIT & confirming to the GTP. 3x240Sqmm.Indoor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 6088.92 | 6088.92 | 4.0 | False | None | None | False | None | False | 24355.68 | 0 | 2958379 | 97769 | None | Code31 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 95 Sqmm, (54 GI Wires - 2.5 mm Dia) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 1154786.47 | 1154786.47 | 0.3 | False | None | None | False | None | False | 346435.941 | 0 | 2958380 | 97769 | None | Code32 | 12 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND
WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per IS-3975. 240 Sqmm, (55 GI Wires - 3.15 mm Dia) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Km | 2149550.3 | 2149550.3 | 0.1 | False | None | None | False | None | False | 214955.03 | 0 | 2958381 | 97769 | None | Code33 | Providing chain link fencing 50 mm size of 8 guage properly stretched between rectangular Poles and fixed with suitable bolts & nuts, the free ends shall be
welded to the Pole and block pipe at top and bottom as required including cost
of all materials, labour, lead and lifts, cutting, bending wherever necessary,
wastage and lapping etc., complete as per the direction of the engineer
incharge for work including two coats of approved quality paint over one coat of primer paint. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1281.13 | 1281.13 | 350.0 | False | None | None | False | None | False | 448395.5 | 0 | 2958382 | 97769 | None | Code34 | Rubber Hand gloves 15 kV, SEAMLESS Confirming to ISS (Sample to be verified for seamless before approval)
for electrical purpose ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Pair | 1466.74 | 1466.74 | 6.0 | False | None | None | False | None | False | 8800.44 | 0 | 2958383 | 97769 | None | Code35 | Supplying of FIRST AID CHART with lamination. Complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 324.5 | 324.5 | 6.0 | False | None | None | False | None | False | 1947.0 | 0 | 2958384 | 97769 | None | Code36 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.65 | 0.65 | 260000.0 | False | None | None | False | None | False | 169000.0 | 0 | 2958385 | 97769 | None | Code37 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 1000Amps double run of 4x60x10mm Aluminum Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 13732.84 | 13732.84 | 15.0 | False | None | None | False | None | False | 205992.6 | 0 | 2958386 | 97769 | None | Code38 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x75x6mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 30.0 | False | None | None | False | None | False | 21611.7 | 0 | 2958387 | 97769 | None | Code39 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75x150x75x6mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 30.0 | False | None | None | False | None | False | 36058.5 | 0 | 2958388 | 97769 | None | Code40 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.FOUR POLE 800Amps 50kA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 64770.2 | 64770.2 | 2.0 | False | None | None | False | None | False | 129540.4 | 0 | 2958389 | 97769 | None | Code41 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 6.0 | False | None | None | False | None | False | 4010.82 | 0 |
| 1709805443000 | 0 | None | None | Buildings | DG set for Hospital | 8808074.36 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958390 | 97770 | None | Code01 | Supplying, installing, testing and commissioning of 250KVA/200kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtrat 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for cons ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 2471808.66 | 2471808.66 | 1.0 | False | None | None | False | None | False | 2471808.66 | 0 | 2958391 | 97770 | None | Code02 | Supplying, installing, testing and commissioning of 320KVA/256kw Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specificationsEngine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor 12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10% for one hour in 12 hours of operation Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have + 1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H. Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight. Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode. Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for co ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 3433003.62 | 3433003.62 | 1.0 | False | None | None | False | None | False | 3433003.62 | 0 | 2958392 | 97770 | None | Code03 | Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 250 KVA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 364800.3 | 364800.3 | 1.0 | False | None | None | False | None | False | 364800.3 | 0 | 2958393 | 97770 | None | Code04 | Supply, Erection, testing and commissioning of AMF panel suitable for .....KVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....amps 4 pole contactor for alternator with thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ KVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Battery charger unit with inbuilt Auto/Manual and flat/Boost facility. 320KVA to 400 KVA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 406028.68 | 406028.68 | 1.0 | False | None | None | False | None | False | 406028.68 | 0 | 2958394 | 97770 | None | Code05 | Supply & installation of exhaust gas piping of suitable diameter as per manufactures standard welded black MS, B class pipe confirming to IS:3589 cut to required lengths and installed with necessary bends, supports and clamps, anti- vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 50mm thick wire mesh & aluminum cladding etc. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 9440.0 | 9440.0 | 40.0 | False | None | None | False | None | False | 377600.0 | 0 | 2958395 | 97770 | None | Code06 | Supply and installing of DG set stack using angular structure, channel, necessary nut and bolt and all required accessories for erecting exhaust pipe from 2 nos DG set and space provision for provinding exhaust pipe for 2 more DG set in future. The design of the stack with foundation shall be got approved before fabrication. The foundation for the stack shall be measured separately. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 236.0 | 236.0 | 1800.0 | False | None | None | False | None | False | 424800.0 | 0 | 2958396 | 97770 | None | Code07 | Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 14SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.65 | 0.65 | 250000.0 | False | None | None | False | None | False | 162500.0 | 0 | 2958397 | 97770 | None | Code08 | Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.600 A 4 x 75 x 10 mm Aluminium Strips ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 7301.25 | 7301.25 | 8.0 | False | None | None | False | None | False | 58410.0 | 0 | 2958398 | 97770 | None | Code09 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 75 x 6 mm ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 720.39 | 720.39 | 16.0 | False | None | None | False | None | False | 11526.24 | 0 | 2958399 | 97770 | None | Code10 | Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channel ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1201.95 | 1201.95 | 16.0 | False | None | None | False | None | False | 19231.2 | 0 | 2958400 | 97770 | None | Code11 | Supplying and fixing of 630A.50KA,Motorised Air Circuit Breaker (ACB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 106200.0 | 106200.0 | 2.0 | False | None | None | False | None | False | 212400.0 | 0 | 2958401 | 97770 | None | Code12 | Supplying and fixing of 400A.50KA,Motorised Air Circuit Breaker (ACB) .over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. (lcu= lcs) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 82600.0 | 82600.0 | 2.0 | False | None | None | False | None | False | 165200.0 | 0 | 2958402 | 97770 | None | Code13 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 10794.17 | 10794.17 | 2.0 | False | None | None | False | None | False | 21588.34 | 0 | 2958403 | 97770 | None | Code14 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12090.87 | 12090.87 | 2.0 | False | None | None | False | None | False | 24181.74 | 0 | 2958404 | 97770 | None | Code15 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 668.47 | 668.47 | 12.0 | False | None | None | False | None | False | 8021.64 | 0 | 2958405 | 97770 | None | Code16 | Supplying, fixing and wiring 1000/5A to 1600/5A 15VA Burden class 1 Current Transformer ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1090.32 | 1090.32 | 6.0 | False | None | None | False | None | False | 6541.92 | 0 | 2958406 | 97770 | None | Code17 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898- 6-32A SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 6.0 | False | None | None | False | None | False | 3232.02 | 0 | 2958407 | 97770 | None | Code18 | 800A, 4P, 50kA, microprocessor based ACB electrical drawout type, motorised with PLC out protection ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 141600.0 | 141600.0 | 1.0 | False | None | None | False | None | False | 141600.0 | 0 | 2958408 | 97770 | None | Code19 | PLC Control:-Supply, Erection, testing and commissioning of Automatic syncronisation with load sharing,RPR,REF,MDM with suitable CT's,Hardware interlocking through Aux contactor with timers , UV and OV, Annunciator, Programmable logic controller 24IP and 24OP,Battery charger,Relay board,AC and DC indicating lamp,Auto sync Relay along with control wiring. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 236000.0 | 236000.0 | 2.0 | False | None | None | False | None | False | 472000.0 | 0 | 2958409 | 97770 | None | Code20 | Supply and laying of 2Cx2.5SQ MM and 6CX2.5 SQ MM Sheilded Sensor and control Cables ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 236.0 | 236.0 | 100.0 | False | None | None | False | None | False | 23600.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | External water supply & Drainage works | 5639064.72 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958410 | 97771 | None | Code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caustion lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other
appurtenaces required to complete the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 628.23 | 628.23 | 579.13 | False | None | None | False | None | False | 363826.8399 | 0 | 2958411 | 97771 | None | Code02 | Filling approved earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm
in depth, consolidating each deposited layer by ramming and watering,
lead up to 50 m and lift upto 1.5 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 562.03 | 562.03 | 579.0 | False | None | None | False | None | False | 325415.37 | 0 | 2958412 | 97771 | None | Code03 | Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2214.39 | 2214.39 | 10.0 | False | None | None | False | None | False | 22143.9 | 0 | 2958413 | 97771 | None | Code04 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 449.11 | 449.11 | 10.0 | False | None | None | False | None | False | 4491.1 | 0 | 2958414 | 97771 | None | Code05 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5498.33 | 5498.33 | 4.0 | False | None | None | False | None | False | 21993.32 | 0 | 2958415 | 97771 | None | Code06 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.(CATCH BASIN) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 7079.29 | 7079.29 | 15.0 | False | None | None | False | None | False | 106189.35 | 0 | 2958416 | 97771 | None | Code07 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 5498.33 | 5498.33 | 10.0 | False | None | None | False | None | False | 54983.3 | 0 | 2958417 | 97771 | None | Code08 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:-Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 37703.01 | 37703.01 | 1.0 | False | None | None | False | None | False | 37703.01 | 0 | 2958418 | 97771 | None | Code09 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:-Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M depth & SFRC cover & frame ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 40718.26 | 40718.26 | 1.0 | False | None | None | False | None | False | 40718.26 | 0 | 2958419 | 97771 | None | Code10 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:-Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.4 M depth & SFRC cover & frame ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 47422.43 | 47422.43 | 1.0 | False | None | None | False | None | False | 47422.43 | 0 | 2958420 | 97771 | None | Code11 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:-Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.6 M depth & SFRC cover & frame ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 53955.26 | 53955.26 | 1.0 | False | None | None | False | None | False | 53955.26 | 0 | 2958421 | 97771 | None | Code12 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:-Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.8 M depth & SFRC cover & frame ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 58264.62 | 58264.62 | 1.0 | False | None | None | False | None | False | 58264.62 | 0 | 2958422 | 97771 | None | Code13 | Providing and constructing "WIRE CUT BRICK MACHINEHOLE CHAMBERS" using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm dia:-Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 2.0 M depth & SFRC cover & frame ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 78897.63 | 78897.63 | 1.0 | False | None | None | False | None | False | 78897.63 | 0 | 2958423 | 97771 | None | Code14 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .-For DI/CI puddle flanges of 80mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2050.84 | 2050.84 | 10.0 | False | None | None | False | None | False | 20508.4 | 0 | 2958424 | 97771 | None | Code15 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .-For DI/CI puddle flanges of 100mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 2415.58 | 2415.58 | 8.0 | False | None | None | False | None | False | 19324.64 | 0 | 2958425 | 97771 | None | Code16 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .-For DI/CI puddle flanges of 150mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 3003.57 | 3003.57 | 6.0 | False | None | None | False | None | False | 18021.42 | 0 | 2958426 | 97771 | None | Code17 | Supplying and fixing DI/CI puddle flanges conforming to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete .-For DI/CI puddle flanges of 200mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 4051.06 | 4051.06 | 2.0 | False | None | None | False | None | False | 8102.12 | 0 | 2958427 | 97771 | None | Code18 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 345.27 | 345.27 | 20.0 | False | None | None | False | None | False | 6905.4 | 0 | 2958428 | 97771 | None | Code19 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: - Sanitary works
-Pipes of SN8 Self Fit - 160mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 800.87 | 800.87 | 135.0 | False | None | None | False | None | False | 108117.45 | 0 | 2958429 | 97771 | None | Code20 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: - Sanitary works
-Pipes of SN8 Self Fit - 200mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1155.22 | 1155.22 | 145.0 | False | None | None | False | None | False | 167506.9 | 0 | 2958430 | 97771 | None | Code21 | Providing UPVC FOAM CORE pipes conforming to IS 16098 P-1 2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete. for: - Sanitary works
-Pipes of SN8 Self Fit - 250mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1775.66 | 1775.66 | 25.0 | False | None | None | False | None | False | 44391.5 | 0 | 2958431 | 97771 | None | Code22 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works-Pipes of SN4, 160mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 747.65 | 747.65 | 125.0 | False | None | None | False | None | False | 93456.25 | 0 | 2958432 | 97771 | None | Code23 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works-Pipes of SN4, 200mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1078.64 | 1078.64 | 175.0 | False | None | None | False | None | False | 188762.0 | 0 | 2958433 | 97771 | None | Code24 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and
conveying to worksite, rolling and lowering into trenches, laying true to
line and level and perfect linking at joints, testing and commissioning,
including loading and unloading at both destinations and cuts of pipes
wherever necessary including jointing of UPVC pipes (with cost of elastomeric rubber rings) and specials (excluding cost of specials) with
jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Rain water works-Pipes of SN4, 250mm dia. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 1653.65 | 1653.65 | 65.0 | False | None | None | False | None | False | 107487.25 | 0 | 2958434 | 97771 | None | Code25 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specifications enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI / NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement . 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the
ANNEXURE : F for Detailed Specification of Each components (For 2000 LPH FRP : Skid Type) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 879524.8 | 879524.8 | 1.0 | False | None | None | False | None | False | 879524.8 | 0 | 2958435 | 97771 | None | Code26 | Automatic Online Hydraulically Operated Self Cleaning Multi grade pressure Filter for the flow rate of ........................... LPH (............... M.L.D) with
16 hour pumping NOTE : For Detailed Specification of Automatic hydraulic self cleaning screen filter(400 Microns), FILTRATION & Filter Media For Pressure Filter, Anthracite, Carbon . Detailed Specification and Rates fot Separate components ( i.e.., Online Sensore, Filtration & Filder media) of 10000 LPH to 225000 LPH Refer Annexure-C (For 10000 & 15000 LPH (0.16 &0.24 M.L.D) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 1260747.4 | 1260747.4 | 1.0 | False | None | None | False | None | False | 1260747.4 | 0 | 2958436 | 97771 | None | Code27 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. (Domestic water pumps from sump OHT) (7.5HP, size 65x50 Head 46.0M, Discharge 360 LPM) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 45624.7 | 45624.7 | 2.0 | False | None | None | False | None | False | 91249.4 | 0 | 2958437 | 97771 | None | Code28 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Job | 8437.0 | 8437.0 | 2.0 | False | None | None | False | None | False | 16874.0 | 0 | 2958438 | 97771 | None | Code29 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. Sump To OHT (FLUSHING Water from STP to OHT) ( 7.5 HP, size 65x50 Head 46M, Discharge 360LPM) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 45624.7 | 45624.7 | 2.0 | False | None | None | False | None | False | 91249.4 | 0 | 2958439 | 97771 | None | Code30 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Job | 8437.0 | 8437.0 | 2.0 | False | None | None | False | None | False | 16874.0 | 0 | 2958440 | 97771 | None | Code31 | HOT WATER SYSTEM -6,000 Litres per day - AIR TO WATER HEAT PUMPDesign, Engineering, Supply and commissioning of Hot water system and Pumps as specified below. Drawings shall be submitted for approval as per site condition.Heat PumpsHot water temperature - 60 CCold water INLET temperature - 25 CRated output heating capacity - 17.00kwDelta T 35 C ( Rise in temperature)The Heat Pump shall have the following specifications :Out put rate 500 Ltrs / hr at 35 deg delta T Heat pump Model: As per manufacturer design / standardHeating Capacity: 43750 Kilo Calorie for each Heat PumpNoise level: 60 dBCompressor : Hermetically Sealed Scroll Compressor UnitEvaporator / cold side heat exchanger Condenser / hot side heat exchangerFlow regulation valve as required, Check valve as requiredTemperature Gauge - as required with Visual indication Necessary Internal controlsRated output heating capacity - 17.00kwInput power consumption-5.0kWInput power supply - 400V/3Ph/50HzWater connection - Inlet and outlet dia - 40 mm dia Inlet water temperature - 25 deg COutlet water temperature - 60 deg C Minimum Co-efficient of performance - 3.5Environmental frendly and CFC free refrigerant viz.,: R407C, R410A, RA17A & R134A Approved Make: Emerson2NOS = (1WORKING+ 1 STD By ) - Emergency all the the four can work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 265500.0 | 265500.0 | 2.0 | False | None | None | False | None | False | 531000.0 | 0 | 2958441 | 97771 | None | Code32 | Supply, Testing and commissioning of approved make circulation pumps for Hot water circulation between the Heat pump and the Mixing Tank. The pumps shall be horizontal multistage type and coupled with suitable TEFC motor of following duty points.
Discharge: 3.8 cum/hr @ 15 meters head.
Make : Grundfos/ wilo /xylem ( Set = 1working + 1 std by ) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 53100.0 | 53100.0 | 3.0 | False | None | None | False | None | False | 159300.0 | 0 | 2958442 | 97771 | None | Code33 | Supply, Testing and commissioning of Electrical panel board for Integration and automatic operation of 2 nos of circulation pumps. The panel shall have separate switch gear for two pumps able to alternate beween working Pump and Stand by Pump for consecutive cycles. The panel shall have dry run protection, over load relay & phase preventor with auto manual operation. (Individual panel for each heat pump)
Make: Aproved sample ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 62304.0 | 62304.0 | 2.0 | False | None | None | False | None | False | 124608.0 | 0 | 2958443 | 97771 | None | Code34 | Interconnecting , installation, testing and commissoning, of fabricated MS tank floor supported horizontal type 2500 litres storage capacity hot water mixing tanks. The tank shall have internally protected with 3mmm thick FRP lining. The tank shall be suitable for a minimum working pressure of 8 kg / sq.cm and a test pressure of 12 kg / sq.cm. The tank shall be fabricated out of 8mm thick MS plate and dish end shall be 8mmm thick. The tank shall be insulated with 100 mm thick PUF / Rockwool insulation having a density of 48 kg / cu.m with best thermal characteristics and lowest heat loss covered with chicken wire mesh including 26 gauge aluminium cladding.
The inside portion of the tank shall be finished with two coats of spary galvanising of 100 microns. Tank shall include 450mm dia manhole, inlet and outlet pipe connections, drain pipe and level indicators, 1nos Pressure gauges, 1nos temperature gauge at inlet and outlet side, flow meter etc. including structural supports for mounting on concrete pedestal. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 295000.0 | 295000.0 | 1.0 | False | None | None | False | None | False | 295000.0 | 0 | 2958444 | 97771 | None | Code35 | Hot Water Return Recirculation pump with Timer Panel Supply, testing and commissioning of hot water recirculation pump (From Hot water network) capacity of as mentioned below including electrical panel board for integration and automatic operation of return hot water circulation pump with necessary timer. etc complete.
Make : Grundfos pump with Panel Duty of pump : 5 cum/hr @ 20 m Head (Set= 1W + 1S Pump+ 1panel ) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 147500.0 | 147500.0 | 1.0 | False | None | None | False | None | False | 147500.0 | 0 | 2958445 | 97771 | None | Code36 | Supply installation, 300mm wide cable tray for running cables from elecytrical control pnael to heat pumps. The scope including neceessary termination of cables. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 590.0 | 590.0 | 45.0 | False | None | None | False | None | False | 26550.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Sump Tank | 3480238.29 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958446 | 97772 | None | Code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 510.11 | 510.11 | 1.79 | False | None | None | False | None | False | 913.0969 | 0 | 2958447 | 97772 | None | Code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 132.4 | 132.4 | 536.76 | False | None | None | False | None | False | 71067.024 | 0 | 2958448 | 97772 | None | Code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 345.27 | 345.27 | 108.02 | False | None | None | False | None | False | 37296.0654 | 0 | 2958449 | 97772 | None | Code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 7773.72 | 7773.72 | 15.81 | False | None | None | False | None | False | 122902.5132 | 0 | 2958450 | 97772 | None | Code05 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates- A. Raft ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 9148.68 | 9148.68 | 30.62 | False | None | None | False | None | False | 280132.5816 | 0 | 2958451 | 97772 | None | Code06 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-pump room and sump tank-walls ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15099.76 | 15099.76 | 39.65 | False | None | None | False | None | False | 598705.484 | 0 | 2958452 | 97772 | None | Code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Cover slab ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13323.32 | 13323.32 | 27.84 | False | None | None | False | None | False | 370921.2288 | 0 | 2958453 | 97772 | None | Code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-D. beams- pumproom ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14211.54 | 14211.54 | 4.72 | False | None | None | False | None | False | 67078.4688 | 0 | 2958454 | 97772 | None | Code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-E. lintel-beam ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14211.54 | 14211.54 | 0.23 | False | None | None | False | None | False | 3268.6542 | 0 | 2958455 | 97772 | None | Code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-Staircase ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12879.21 | 12879.21 | 1.84 | False | None | None | False | None | False | 23697.7464 | 0 | 2958456 | 97772 | None | Code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 102556.28 | 102556.28 | 10.2 | False | None | None | False | None | False | 1046074.056 | 0 | 2958457 | 97772 | None | Code12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1700.38 | 1700.38 | 36.12 | False | None | None | False | None | False | 61417.7256 | 0 | 2958458 | 97772 | None | Code13 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5812.44 | 5812.44 | 4.2 | False | None | None | False | None | False | 24412.248 | 0 | 2958459 | 97772 | None | Code14 | UGT/OHT (inside) waterproofing with Anti-microbial Coating Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster, and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2171.55 | 2171.55 | 186.24 | False | None | None | False | None | False | 404429.472 | 0 | 2958460 | 97772 | None | Code15 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 481.56 | 481.56 | 582.24 | False | None | None | False | None | False | 280383.4944 | 0 | 2958461 | 97772 | None | Code16 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 149.27 | 149.27 | 7.08 | False | None | None | False | None | False | 1056.8316 | 0 | 2958462 | 97772 | None | Code17 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 33.75 | 33.75 | 511.12 | False | None | None | False | None | False | 17250.3 | 0 | 2958463 | 97772 | None | Code18 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 115.52 | 115.52 | 511.12 | False | None | None | False | None | False | 59044.5824 | 0 | 2958464 | 97772 | None | Code19 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2546.68 | 2546.68 | 4.0 | False | None | None | False | None | False | 10186.72 | 0 |
| 1709805443000 | 0 | None | None | Buildings | STP 30 KLD | 5540232.18 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958465 | 97773 | None | Code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 510.11 | 510.11 | 0.66 | False | None | None | False | None | False | 336.6726 | 0 | 2958466 | 97773 | None | Code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 132.4 | 132.4 | 157.34 | False | None | None | False | None | False | 20831.816 | 0 | 2958467 | 97773 | None | Code03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 471.17 | 471.17 | 19.67 | False | None | None | False | None | False | 9267.9139 | 0 | 2958468 | 97773 | None | Code04 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 m ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 551.65 | 551.65 | 19.67 | False | None | None | False | None | False | 10850.9555 | 0 | 2958469 | 97773 | None | Code05 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 175.23 | 175.23 | 89.34 | False | None | None | False | None | False | 15655.0482 | 0 | 2958470 | 97773 | None | Code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 345.27 | 345.27 | 157.34 | False | None | None | False | None | False | 54324.7818 | 0 | 2958471 | 97773 | None | Code07 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 7773.72 | 7773.72 | 6.56 | False | None | None | False | None | False | 50995.6032 | 0 | 2958472 | 97773 | None | Code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork - Footing ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 9148.68 | 9148.68 | 10.97 | False | None | None | False | None | False | 100361.0196 | 0 | 2958473 | 97773 | None | Code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-WALLS ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 15099.76 | 15099.76 | 47.54 | False | None | None | False | None | False | 717842.5904 | 0 | 2958474 | 97773 | None | Code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-SLAB ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13323.32 | 13323.32 | 13.52 | False | None | None | False | None | False | 180131.2864 | 0 | 2958475 | 97773 | None | Code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-ROOF BEAM ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 14211.54 | 14211.54 | 3.82 | False | None | None | False | None | False | 54288.0828 | 0 | 2958476 | 97773 | None | Code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 12478.32 | 12478.32 | 0.28 | False | None | None | False | None | False | 3493.9296 | 0 | 2958477 | 97773 | None | Code13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 102556.28 | 102556.28 | 12.61 | False | None | None | False | None | False | 1293234.6908 | 0 | 2958478 | 97773 | None | Code14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1700.38 | 1700.38 | 160.2 | False | None | None | False | None | False | 272400.876 | 0 | 2958479 | 97773 | None | Code15 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 5812.44 | 5812.44 | 4.2 | False | None | None | False | None | False | 24412.248 | 0 | 2958480 | 97773 | None | Code16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kg | 218.06 | 218.06 | 75.6 | False | None | None | False | None | False | 16485.336 | 0 | 2958481 | 97773 | None | Code17 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall
be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 8740.73 | 8740.73 | 3.6 | False | None | None | False | None | False | 31466.628 | 0 | 2958482 | 97773 | None | Code18 | STP (inside) waterproofing with Anticorrosive & Protective Coating--Providing and Applying two component coal tar epoxy-based coating on inside surface of Sewage & Effluent treatment tank @ 0.30 kg/m2 in 2 coats to achieve a DFT of 200 microns when fully cured. Ensure that this coating is applied over the protective plaster and that Item No. 4 is completed across the entire surface prior to applying the protective plaster. The Waterproofing material shall have Scratch resistance, for 7kg load as per ASTM : D 7027 - 05, Chemical resistance, immersion in dilute acid alkali & salt solutions 7 days confirms to ASTM : C 868, Salt Spray resistance confirms to ASTM : B 117. The finished cost to include surface preparation completely as per specification. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 2161.17 | 2161.17 | 242.02 | False | None | None | False | None | False | 523046.3634 | 0 | 2958483 | 97773 | None | Code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 481.56 | 481.56 | 578.02 | False | None | None | False | None | False | 278351.3112 | 0 | 2958484 | 97773 | None | Code20 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 64.9 | 64.9 | 7.8 | False | None | None | False | None | False | 506.22 | 0 | 2958485 | 97773 | None | Code21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 149.27 | 149.27 | 7.8 | False | None | None | False | None | False | 1164.306 | 0 | 2958486 | 97773 | None | Code22 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 33.75 | 33.75 | 578.02 | False | None | None | False | None | False | 19508.175 | 0 | 2958487 | 97773 | None | Code23 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 Sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 115.52 | 115.52 | 578.02 | False | None | None | False | None | False | 66772.8704 | 0 | 2958488 | 97773 | None | Code24 | Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2546.68 | 2546.68 | 8.0 | False | None | None | False | None | False | 20373.44 | 0 | 2958489 | 97773 | None | Code25 | BAR SCREEN with 20 mm spacingMOC: MSEPMake: Hydrodrops ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 11800.0 | 11800.0 | 1.0 | False | None | None | False | None | False | 11800.0 | 0 | 2958490 | 97773 | None | Code26 | Coarse Bubble DiffusersSize: 80 mm dia x 800 mm longTYPE: Tubular TypeMOC: PVCMake: Energy Equipments/SSI USA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 3245.0 | 3245.0 | 10.0 | False | None | None | False | None | False | 32450.0 | 0 | 2958491 | 97773 | None | Code27 | Fine Bubble DiffusersSize: 90 mm dia x 800 mm longTYPE: Tubular TypeMOC: EPDMMake: Energy Equipments/SSI USA ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4130.0 | 4130.0 | 10.0 | False | None | None | False | None | False | 41300.0 | 0 | 2958492 | 97773 | None | Code28 | Raw Effluent PumpsDuty: 12 cum/hr @ 10 m headTYPE: Vertical, Submersible, Non clogMOC: CIMake: CNP/Point/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 44840.0 | 44840.0 | 2.0 | False | None | None | False | None | False | 89680.0 | 0 | 2958493 | 97773 | None | Code29 | Filter Feed PumpsDuty: 12 cum/hr @ 35 m headTYPE: Horizontal, Centrifugal, Non clogMOC: CIMake: Kirloskar/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 35400.0 | 35400.0 | 2.0 | False | None | None | False | None | False | 70800.0 | 0 | 2958494 | 97773 | None | Code30 | Air Blowers (For SBR Tank)Type: Twin lobe Flow Rate: 160 cum/hrOperating Pressure: 0.5 Kg/cm²Speed: 1440 rpmMOC: CIMake: TMVT/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 153400.0 | 153400.0 | 2.0 | False | None | None | False | None | False | 306800.0 | 0 | 2958495 | 97773 | None | Code31 | Sludge Transfer PumpsDuty: 5 cum/hr @ 10 m headTYPE: Vertical, Submersible, Non clogMOC: CIMake: CNP/Point/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 2958496 | 97773 | None | Code32 | Hypochlorite Dosing PumpCapacity: 0 - 6 lphMOC: PPMake: Positive/Ant/EquivDosing tank capacity: 100 ltsMOC: HDPEMake: Syntex/Infra/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 2958497 | 97773 | None | Code33 | Pressure Sand FilterDuty: 15 cum/hrType: Vertical, CylindricalSize: 800 mm dia x 1200 mm HOSMedia: Graded sand and pebblesMOC:MSEPMake: Hydrodrops ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 135700.0 | 135700.0 | 1.0 | False | None | None | False | None | False | 135700.0 | 0 | 2958498 | 97773 | None | Code34 | Activated Carbon FilterDuty: 15 cum/hrType: Vertical, CylindricalSize: 800 mm dia x 1200 mm HOSMedia: Activated Carbon, Gravels and pebblesMOC:MSEPMake: Hydrodrops ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 141600.0 | 141600.0 | 1.0 | False | None | None | False | None | False | 141600.0 | 0 | 2958499 | 97773 | None | Code35 | Filter PressSize: 470 mm x 470 mm with 12 platesMake: Precision/Hydropress/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 153400.0 | 153400.0 | 1.0 | False | None | None | False | None | False | 153400.0 | 0 | 2958500 | 97773 | None | Code36 | Screw PumpDuty: 1 cum/hr @ 60 m headType: Horizontal, screw pump with SS rotor & stator for pressure pumpingMOC: CIMake: Alfa/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 35400.0 | 35400.0 | 1.0 | False | None | None | False | None | False | 35400.0 | 0 | 2958501 | 97773 | None | Code37 | Decanter Mechanism ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 82600.0 | 82600.0 | 1.0 | False | None | None | False | None | False | 82600.0 | 0 | 2958502 | 97773 | None | Code38 | Interconnecting piping, fittings & valvesMOC: GI/PVCMake:GI/MS: Tata/Jindal/EquivPVC: Supreme/Equiv ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Lot | 129800.0 | 129800.0 | 1.0 | False | None | None | False | None | False | 129800.0 | 0 | 2958503 | 97773 | None | Code39 | Electrical Control PanelType: Powder coated, CRCA, 16 gauge sheet, weather proof, cubicle tyep, floor mounted.Function: Auto manual PLC with HDMI Monitor ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 177000.0 | 177000.0 | 1.0 | False | None | None | False | None | False | 177000.0 | 0 | 2958504 | 97773 | None | Code40 | UV Disinfection SystemFlow: 10 cum/hrMake: Alfa ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 | 2958505 | 97773 | None | Code41 | Electrical Cabling work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Lot | 29500.0 | 29500.0 | 1.0 | False | None | None | False | None | False | 29500.0 | 0 | 2958506 | 97773 | None | Code42 | Instrumentation: Float switches, pressure guages, flowmeter ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Lot | 41300.0 | 41300.0 | 1.0 | False | None | None | False | None | False | 41300.0 | 0 | 2958507 | 97773 | None | Code43 | Erection & Commissioning ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | LS | 118000.0 | 118000.0 | 1.0 | False | None | None | False | None | False | 118000.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | 5 KLD ETP | 1743239.96 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958508 | 97774 | None | code01 | Modular - ETP : Consists of MS fabricated ETP plant, effluent transfer pumps, effluent agitator, sludge disposal pump, chemical dosing pumps, MCC panel complete - 10KLD ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 1743239.96 | 1743239.96 | 1.0 | False | None | None | False | None | False | 1743239.96 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Bituminous Road | 2394370.89 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958509 | 97775 | None | Code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 510.11 | 510.11 | 16.0 | False | None | None | False | None | False | 8161.76 | 0 | 2958510 | 97775 | None | Code02 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 123.31 | 123.31 | 480.0 | False | None | None | False | None | False | 59188.8 | 0 | 2958511 | 97775 | None | Code03 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 314.12 | 314.12 | 144.0 | False | None | None | False | None | False | 45233.28 | 0 | 2958512 | 97775 | None | Code04 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 110.33 | 110.33 | 96.0 | False | None | None | False | None | False | 10591.68 | 0 | 2958513 | 97775 | None | Code05 | Making 50 mm x 50 mm furrows, 25mm/ 50mm deep, 45 degrees to the center line of the road and at one metre interval in the existing thin bituminous wearing coarse including sweeping and disposal of excavated material.25 mm deep furrow cutting ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 10.38 | 10.38 | 960.0 | False | None | None | False | None | False | 9964.8 | 0 | 2958514 | 97775 | None | Code06 | Compacting original ground supporting embankment-Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 136.29 | 136.29 | 144.0 | False | None | None | False | None | False | 19625.76 | 0 | 2958515 | 97775 | None | Code07 | Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 615.25 | 615.25 | 480.0 | False | None | None | False | None | False | 295320.0 | 0 | 2958516 | 97775 | None | Code08 | Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401 .For Grading -V Material ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 3228.13 | 3228.13 | 96.0 | False | None | None | False | None | False | 309900.48 | 0 | 2958517 | 97775 | None | Code09 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 3107.41 | 3107.41 | 96.0 | False | None | None | False | None | False | 298311.36 | 0 | 2958518 | 97775 | None | Code10 | Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/m2 using mechanical means. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 53.22 | 53.22 | 960.0 | False | None | None | False | None | False | 51091.2 | 0 | 2958519 | 97775 | None | Code11 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 15.58 | 15.58 | 960.0 | False | None | None | False | None | False | 14956.8 | 0 | 2958520 | 97775 | None | Code12 | Providing and laying Bituminous Macadam with 120 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG- 40 @ 3.3% by weight of mix, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 10069.88 | 10069.88 | 72.0 | False | None | None | False | None | False | 725031.36 | 0 | 2958521 | 97775 | None | Code13 | Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler, transported to site, laid over a previously prepared surface with mechanical paver finisher to the required grade, level and alignment and rolled as per MoRTH V revision. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 13177.3 | 13177.3 | 24.0 | False | None | None | False | None | False | 316255.2 | 0 | 2958522 | 97775 | None | Code14 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 7773.72 | 7773.72 | 9.6 | False | None | None | False | None | False | 74627.712 | 0 | 2958523 | 97775 | None | Code15 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra)600 x 200 x 100 mm Kerb Stone ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 324.5 | 324.5 | 320.0 | False | None | None | False | None | False | 103840.0 | 0 | 2958524 | 97775 | None | Code16 | Construction of Median and Island above road level with approved material deposited at site from roadway cutting and excavation for drain and foundation of other structures, spread, graded and compacted as per clause 408 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 476.37 | 476.37 | 43.2 | False | None | None | False | None | False | 20579.184 | 0 | 2958525 | 97775 | None | Code17 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 141.48 | 141.48 | 224.0 | False | None | None | False | None | False | 31691.52 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Drain | 1953282.72 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958526 | 97776 | None | Code01 | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Mechanical Means using Dozer In area of light jungle ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 510.11 | 510.11 | 0.96 | False | None | None | False | None | False | 489.7056 | 0 | 2958527 | 97776 | None | Code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work 1.14.1 In all kinds of soils Depth upto 3 m. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 132.4 | 132.4 | 384.0 | False | None | None | False | None | False | 50841.6 | 0 | 2958528 | 97776 | None | Code03 | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum. (Disposal of 10Km) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 175.23 | 175.23 | 192.0 | False | None | None | False | None | False | 33644.16 | 0 | 2958529 | 97776 | None | Code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates. Including FormWork ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 7773.72 | 7773.72 | 32.0 | False | None | None | False | None | False | 248759.04 | 0 | 2958530 | 97776 | None | Code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-Base slab (VENT PORTION) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 8863.91 | 8863.91 | 28.8 | False | None | None | False | None | False | 255280.608 | 0 | 2958531 | 97776 | None | Code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.Including FormWork-Side wall ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 11617.75 | 11617.75 | 38.4 | False | None | None | False | None | False | 446121.6 | 0 | 2958532 | 97776 | None | Code07 | Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 1204.54 | 1204.54 | 288.0 | False | None | None | False | None | False | 346907.52 | 0 | 2958533 | 97776 | None | Code08 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | t | 102556.28 | 102556.28 | 5.57 | False | None | None | False | None | False | 571238.4796 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Signages | 1728051.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958534 | 97777 | None | Code01 | Pharmacy3D Acrylic Channel letters - 100mm thick - internally lit with LEDs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 65372.0 | 65372.0 | 1.0 | False | None | None | False | None | False | 65372.0 | 0 | 2958535 | 97777 | None | Code02 | Emergency3D Acrylic Channel letters - 100mm thick - internally lit with LEDs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 147972.0 | 147972.0 | 1.0 | False | None | None | False | None | False | 147972.0 | 0 | 2958536 | 97777 | None | Code03 | Department Names - 3D3D 40mm SS Mirror Finish channel letters - Non Lit ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 26550.0 | 26550.0 | 15.0 | False | None | None | False | None | False | 398250.0 | 0 | 2958537 | 97777 | None | Code04 | Floor DirectoryAcid Etching on SS fixed on Acrylic ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 15104.0 | 15104.0 | 5.0 | False | None | None | False | None | False | 75520.0 | 0 | 2958538 | 97777 | None | Code05 | Room Identification SignageSS Acid etching ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1321.6 | 1321.6 | 20.0 | False | None | None | False | None | False | 26432.0 | 0 | 2958539 | 97777 | None | Code06 | Perpendicular SignageSS Acid etching stuck on Acrylic ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2242.0 | 2242.0 | 15.0 | False | None | None | False | None | False | 33630.0 | 0 | 2958540 | 97777 | None | Code07 | Nurse Station 3D signage3D Aluminium Channel Letter ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9145.0 | 9145.0 | 2.0 | False | None | None | False | None | False | 18290.0 | 0 | 2958541 | 97777 | None | Code08 | Ceiling Suspended Direction SignageAluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4484.0 | 4484.0 | 8.0 | False | None | None | False | None | False | 35872.0 | 0 | 2958542 | 97777 | None | Code09 | Lift IdenticiationAcrylic Signage ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 2958543 | 97777 | None | Code10 | Information SignageSS Acid etching ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9145.0 | 9145.0 | 15.0 | False | None | None | False | None | False | 137175.0 | 0 | 2958544 | 97777 | None | Code11 | Bed NumbersAcrylic Signage ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 472.0 | 472.0 | 15.0 | False | None | None | False | None | False | 7080.0 | 0 | 2958545 | 97777 | None | Code12 | Mandatory Signage A45MM Sunboard with vinyl ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1770.0 | 1770.0 | 15.0 | False | None | None | False | None | False | 26550.0 | 0 | 2958546 | 97777 | None | Code13 | Mandatory Signage A05MM Sunboard with vinyl ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2950.0 | 2950.0 | 5.0 | False | None | None | False | None | False | 14750.0 | 0 | 2958547 | 97777 | None | Code14 | Room Identification SignageSS Acid etching ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1321.6 | 1321.6 | 10.0 | False | None | None | False | None | False | 13216.0 | 0 | 2958548 | 97777 | None | Code15 | Nurse Station 3D signage3D Aluminium Channel Letter ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 9145.0 | 9145.0 | 2.0 | False | None | None | False | None | False | 18290.0 | 0 | 2958549 | 97777 | None | Code16 | Patient Identification BoardsAcrylic A4 size inserts ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2950.0 | 2950.0 | 2.0 | False | None | None | False | None | False | 5900.0 | 0 | 2958550 | 97777 | None | Code17 | Floor DirectoryAcid Etching on SS fixed on Acrylic ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 10030.0 | 10030.0 | 2.0 | False | None | None | False | None | False | 20060.0 | 0 | 2958551 | 97777 | None | Code18 | Ceiling Suspended Direction SignageAluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 4484.0 | 4484.0 | 4.0 | False | None | None | False | None | False | 17936.0 | 0 | 2958552 | 97777 | None | Code19 | Perpendicular SigangeSS Acid etching stuck on Acrylic ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2242.0 | 2242.0 | 15.0 | False | None | None | False | None | False | 33630.0 | 0 | 2958553 | 97777 | None | Code20 | Department 3D Signage3D 40mm SS Mirror Finish channel letters - Non Lit ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 26550.0 | 26550.0 | 5.0 | False | None | None | False | None | False | 132750.0 | 0 | 2958554 | 97777 | None | Code21 | Lift IdenticiationAcrylic Signage ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2950.0 | 2950.0 | 4.0 | False | None | None | False | None | False | 11800.0 | 0 | 2958555 | 97777 | None | Code22 | Information SignageSS Acid etching ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 8850.0 | 8850.0 | 3.0 | False | None | None | False | None | False | 26550.0 | 0 | 2958556 | 97777 | None | Code23 | Bed NumbersAcrylic Signage ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 472.0 | 472.0 | 20.0 | False | None | None | False | None | False | 9440.0 | 0 | 2958557 | 97777 | None | Code24 | Mandatory Signage A45MM Sunboard with vinyl ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 1770.0 | 1770.0 | 8.0 | False | None | None | False | None | False | 14160.0 | 0 | 2958558 | 97777 | None | Code25 | Mandatory Signage A05MM Sunboard with vinyl ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 2950.0 | 2950.0 | 4.0 | False | None | None | False | None | False | 11800.0 | 0 | 2958559 | 97777 | None | Code26 | BUILDING SIGNAGEAluminum Modular Signage using Aluminum alloy 6063 extrusion with Anodizing (thickness typically to be 30 microns. The integrity to meet international specifications ISO 2143-1981) with life time warranty in normal working conditions. Clear Cover : Clear UV protected 1mm thick Poly carbonate sheet with non Glare/glossy finish. Size - 210 X 700. ON THE BUILDING ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 419726.0 | 419726.0 | 1.0 | False | None | None | False | None | False | 419726.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Landscape | 1140131.73 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958560 | 97778 | None | Code01 | SCRAPPING AND REMOVING TOP SOIL:-Scrappingtheareabyremoving0.15msoilandremovingofunwantedplants,grassalongwithroots.25kminitialtransport,including lead, lift loading and unloading charges. (1x1x0.15mt) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 55.45 | 55.45 | 148.5 | False | None | None | False | None | False | 8234.325 | 0 | 2958561 | 97778 | None | Code02 | 1st DIGGING: Diggingoftheareafordevelopinglawnincludingremovingweeds,debris if any and breaking of clumps, watering etc. (1x1x0.45mt) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 98.62 | 98.62 | 445.5 | False | None | None | False | None | False | 43935.21 | 0 | 2958562 | 97778 | None | Code03 | 2nd DIGGING:-Diggingofsoilbyremovinggrassetcifanyandlevellingofthesoiletc .. (1x1x0.45mt) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 49.31 | 49.31 | 445.5 | False | None | None | False | None | False | 21967.605 | 0 | 2958563 | 97778 | None | Code04 | Procurement of quality red earth/soil and heap around pit (1x1x0.15mt) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 93.96 | 93.96 | 148.5 | False | None | None | False | None | False | 13953.06 | 0 | 2958564 | 97778 | None | Code05 | Supply of inputs suchassand,FYM,Redearthin1:3:6ratio.mixingandspreadingthe mixture to 7.50cm thickness wherever required.* Red soil-0.0075cum, *Farm Yard manure-0.0225cum, * Sand-0.045cum ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Cum | 141.35 | 141.35 | 74.25 | False | None | None | False | None | False | 10495.2375 | 0 | 2958565 | 97778 | None | Code06 | Supply of Fertiliser--Super Phosphate -50 gram, Neem oilcake -250gram, Bone meal-250gram, Potash-50gram,Furadan-25gram,Ammonium Sulphate-100gram,Chlorophyriphos-0.05 mili ltr.(Total 750 Gram) per kg 22 rs/- ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 22.07 | 22.07 | 990.0 | False | None | None | False | None | False | 21849.3 | 0 | 2958566 | 97778 | None | Code07 | Procurement of quality lawn grass Bermuda Grass ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 129.8 | 129.8 | 450.0 | False | None | None | False | None | False | 58410.0 | 0 | 2958567 | 97778 | None | Code08 | Procurement of quality lawn grass Mexican Grass ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 259.6 | 259.6 | 450.0 | False | None | None | False | None | False | 116820.0 | 0 | 2958568 | 97778 | None | Code09 | Labour Charges mixing Inputs as perprescribed proportion and quantity and spreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.-Bermuda Grass turf ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 629.53 | 629.53 | 450.0 | False | None | None | False | None | False | 283288.5 | 0 | 2958569 | 97778 | None | Code10 | Labour Charges mixing Inputs as perprescribed proportion and quantity and spreading,applyingfertilizers,digging,levelling,anddibblingwithlawngrassataspacingof5cmx5cm& as per the direction of the Officer in charge of the work.-Mexican grass turf ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sqm | 759.33 | 759.33 | 450.0 | False | None | None | False | None | False | 341698.5 | 0 | 2958570 | 97778 | None | Code11 | Providing and fixing Green 50 Liter Industrial Dustbin, Size: L 42 X W 47 X H 65 Cm of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 1681.5 | 1681.5 | 20.0 | False | None | None | False | None | False | 33630.0 | 0 | 2958571 | 97778 | None | Code12 | Providing and fixing Outdoor Stone Garden Bench BENCHES (5'*2') of approved make including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | No | 37170.0 | 37170.0 | 5.0 | False | None | None | False | None | False | 185850.0 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Borewell | 678354.28 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958572 | 97779 | None | Code01 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indic ting the location of the site, recommended depth of casing pipe required seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casin pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging techn al personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above M and upto 30 M - 15%,
b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of R . 100/- is to be deducted for Dry Borewell towards yield test. tc. complete. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 6863.82 | 6863.82 | 1.0 | False | None | None | False | None | False | 6863.82 | 0 | 2958573 | 97779 | None | Code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 0 to 50 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 480.26 | 480.26 | 50.0 | False | None | None | False | None | False | 24013.0 | 0 | 2958574 | 97779 | None | Code03 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 50 to 100 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 602.27 | 602.27 | 50.0 | False | None | None | False | None | False | 30113.5 | 0 | 2958575 | 97779 | None | Code04 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 100 to 150 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 639.91 | 639.91 | 50.0 | False | None | None | False | None | False | 31995.5 | 0 | 2958576 | 97779 | None | Code05 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 150 to 200 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 742.46 | 742.46 | 50.0 | False | None | None | False | None | False | 37123.0 | 0 | 2958577 | 97779 | None | Code06 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 200 to 250 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 870.96 | 870.96 | 50.0 | False | None | None | False | None | False | 43548.0 | 0 | 2958578 | 97779 | None | Code07 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 250 to 300 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 960.52 | 960.52 | 50.0 | False | None | None | False | None | False | 48026.0 | 0 | 2958579 | 97779 | None | Code08 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth)-Borewell depth of 300 to 350 Mtrs ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 1126.66 | 1126.66 | 50.0 | False | None | None | False | None | False | 56333.0 | 0 | 2958580 | 97779 | None | Code09 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 nd latest ammendments, electrical resistance welded steel tubes, terial and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixe with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 2509.03 | 2509.03 | 35.0 | False | None | None | False | None | False | 87816.05 | 0 | 2958581 | 97779 | None | Code10 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Mtr | 713.9 | 713.9 | 200.0 | False | None | None | False | None | False | 142780.0 | 0 | 2958582 | 97779 | None | Code11 | Providing and fixing MS casing collars per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thic ness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 194.7 | 194.7 | 1.0 | False | None | None | False | None | False | 194.7 | 0 | 2958583 | 97779 | None | Code12 | Providing and laying at site of wor MS asing caps as per IS 1239 (part- II) 1982 with all latest amendm nts if any for any dia. The thickness of plate used for covering one e shall be 3mm (minimum). The dimensions of caps and olars shall be strictly as per IS 1239 (Part-II) 1982 with all mendments including cost of material and labour charges for fixing, if a y etc. complete with all lead and lifts and as directed by the Engineer in charge. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 212.87 | 212.87 | 1.0 | False | None | None | False | None | False | 212.87 | 0 | 2958584 | 97779 | None | Code13 | Providing NP/CP 50mm dia Waste Unions conforming to ISI specifications and fixing them in position as per directions (Rates includes cost of materials fixtures and conveyance to work spot etc complete) ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Nos | 272.58 | 272.58 | 1.0 | False | None | None | False | None | False | 272.58 | 0 | 2958585 | 97779 | None | Code14 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For HP etc Complete.5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 41713.83 | 41713.83 | 1.0 | False | None | None | False | None | False | 41713.83 | 0 | 2958586 | 97779 | None | Code15 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protectionsuitable for thepumpdescribedabove 1 no Indoor type NOTE: 1) DOL- Direct Online Starter
2) S-D- Star Delta Starter etc. complete.3 to 6 HP pumps ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 12395.9 | 12395.9 | 1.0 | False | None | None | False | None | False | 12395.9 | 0 | 2958587 | 97779 | None | Code16 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Set | 2011.9 | 2011.9 | 1.0 | False | None | None | False | None | False | 2011.9 | 0 | 2958588 | 97779 | None | Code17 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Job | 51.92 | 51.92 | 100.0 | False | None | None | False | None | False | 5192.0 | 0 | 2958589 | 97779 | None | Code18 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Job | 8437.0 | 8437.0 | 1.0 | False | None | None | False | None | False | 8437.0 | 0 | 2958590 | 97779 | None | Code19 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Job | 1752.3 | 1752.3 | 1.0 | False | None | None | False | None | False | 1752.3 | 0 | 2958591 | 97779 | None | Code20 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 4 mm2 ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | m | 218.06 | 218.06 | 275.0 | False | None | None | False | None | False | 59966.5 | 0 | 2958592 | 97779 | None | Code21 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16SWG ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Sq CM | 0.56 | 0.56 | 30000.0 | False | None | None | False | None | False | 16800.0 | 0 | 2958593 | 97779 | None | Code22 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 600mmx600mmx170mm. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 18846.96 | 18846.96 | 1.0 | False | None | None | False | None | False | 18846.96 | 0 | 2958594 | 97779 | None | Code23 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 423.32 | 423.32 | 1.0 | False | None | None | False | None | False | 423.32 | 0 | 2958595 | 97779 | None | Code24 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A SP ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 538.67 | 538.67 | 1.0 | False | None | None | False | None | False | 538.67 | 0 | 2958596 | 97779 | None | Code25 | Fixing of ..... A TPST / change over switch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling..15A to 63A TPST ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Each | 360.84 | 360.84 | 1.0 | False | None | None | False | None | False | 360.84 | 0 | 2958597 | 97779 | None | Code26 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Kvar | 623.04 | 623.04 | 1.0 | False | None | None | False | None | False | 623.04 | 0 |
| 1709805443000 | 0 | None | None | Buildings | Consultancy charges for Architectural Structural & DPR charges | 4000000.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2958598 | 97780 | None | code01 | Preparation of Architectural / Structural design and drawings as per I.S Codes including proof checking by reputed Government/Semi Government/Technical Education Universities decided by the Department and the same has to be furnished to the Department for approval and any other drawings related to this project. (6 sets of as built drawings shall be submitted to the employer) Note - All required service GFC drawings required for completion of projects. - etc., complete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., Complete as per Specification and as Directed by the Engineer in charge of Work | Job | 4000000.0 | 4000000.0 | 1.0 | False | None | None | False | None | False | 4000000.0 | 0 |
|
|
---|