tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1709953928000 | 1 | None | None | Buildings | Construction of single class room building at Government lower primary school at AD Gudda gollarahatti | 1162910.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2973424 | 98516 | None | code01 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge | Sqm | 193.2 | 193.2 | 6.84 | False | None | None | False | None | False | 1321.488 | 0 | 2973425 | 98516 | None | code02 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 828.45 | 828.45 | 3.5 | False | None | None | False | None | False | 2899.575 | 0 | 2973426 | 98516 | None | code03 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 387.45 | 387.45 | 16.01 | False | None | None | False | None | False | 6203.0745 | 0 | 2973427 | 98516 | None | code04 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredto complete the work. | Cum | 195.3 | 195.3 | 45.63 | False | None | None | False | None | False | 8911.539 | 0 | 2973428 | 98516 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5831.7 | 5831.7 | 12.04 | False | None | None | False | None | False | 70213.668 | 0 | 2973429 | 98516 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) uptoplinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 4987.5 | 4987.5 | 14.05 | False | None | None | False | None | False | 70074.375 | 0 | 2973430 | 98516 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5619.6 | 5619.6 | 11.8091 | False | None | None | False | None | False | 66362.41836 | 0 | 2973431 | 98516 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 1.61 | False | None | None | False | None | False | 10450.671 | 0 | 2973432 | 98516 | None | code09 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along theexternal perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 99.75 | 99.75 | 5.69 | False | None | None | False | None | False | 567.5775 | 0 | 2973433 | 98516 | None | code10 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 208.95 | 208.95 | 22.485 | False | None | None | False | None | False | 4698.24075 | 0 | 2973434 | 98516 | None | code11 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 214.2 | 214.2 | 76.42 | False | None | None | False | None | False | 16369.164 | 0 | 2973435 | 98516 | None | code12 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7295.4 | 7295.4 | 18.8 | False | None | None | False | None | False | 137153.52 | 0 | 2973436 | 98516 | None | code13 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6780.18 | 6780.18 | 6.08 | False | None | None | False | None | False | 41223.4944 | 0 | 2973437 | 98516 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10672.52 | 10672.52 | 6.05 | False | None | None | False | None | False | 64568.746 | 0 | 2973438 | 98516 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6767.71 | 6767.71 | 2.54 | False | None | None | False | None | False | 17189.9834 | 0 | 2973439 | 98516 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10392.48 | 10392.48 | 3.96 | False | None | None | False | None | False | 41154.2208 | 0 | 2973440 | 98516 | None | code17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9742.95 | 9742.95 | 10.28 | False | None | None | False | None | False | 100157.526 | 0 | 2973441 | 98516 | None | code18 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 9418.19 | 9418.19 | 0.14 | False | None | None | False | None | False | 1318.5466 | 0 | 2973442 | 98516 | None | code19 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately | Kgs | 96.6 | 96.6 | 2451.96 | False | None | None | False | None | False | 236859.336 | 0 | 2973443 | 98516 | None | code20 | KSRB15-3.10 : Providing 20mm thick cement plaster in single coat with cement mortar 1:3, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. | Sqm | 386.4 | 386.4 | 68.5574 | False | None | None | False | None | False | 26490.57936 | 0 | 2973444 | 98516 | None | code21 | KSRB 15-4.6 : Extra for Providing and mixing waterproofing compound in cement plaster for brick masonry work at one kg per bag or in the proportion recommended by the manufactures, for cement mortar 1:3, 20mm thick cost of materials complete as per specifications. | Sqm | 53.55 | 53.55 | 68.5574 | False | None | None | False | None | False | 3671.24877 | 0 | 2973445 | 98516 | None | code22 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per
specifications and as per directions of Engineer-in-charge | Sqm | 260.4 | 260.4 | 69.36 | False | None | None | False | None | False | 18061.344 | 0 | 2973446 | 98516 | None | code23 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 322.35 | 322.35 | 128.04 | False | None | None | False | None | False | 41273.694 | 0 | 2973447 | 98516 | None | code24 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, includingapplying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 3843.0 | 3843.0 | 2.52 | False | None | None | False | None | False | 9684.36 | 0 | 2973448 | 98516 | None | code25 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 110.25 | 110.25 | 120.96 | False | None | None | False | None | False | 13335.84 | 0 | 2973449 | 98516 | None | code26 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 126.0 | 126.0 | 120.96 | False | None | None | False | None | False | 15240.96 | 0 | 2973450 | 98516 | None | code27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Sqm | 152.25 | 152.25 | 18.9 | False | None | None | False | None | False | 2877.525 | 0 | 2973451 | 98516 | None | code28 | looring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.. | Sqm | 1251.6 | 1251.6 | 50.56 | False | None | None | False | None | False | 63280.896 | 0 | 2973452 | 98516 | None | code29 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 99.75 | 99.75 | 119.92 | False | None | None | False | None | False | 11962.02 | 0 | 2973453 | 98516 | None | code30 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work over and including priming coat of exterior primer applie | Sqm | 138.6 | 138.6 | 128.03 | False | None | None | False | None | False | 17744.958 | 0 | 2973454 | 98516 | None | code31 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.5 | 94.5 | 20.6549 | False | None | None | False | None | False | 1951.88805 | 0 | 2973455 | 98516 | None | code32 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. | Kgs | 116.55 | 116.55 | 60.0 | False | None | None | False | None | False | 6993.0 | 0 | 2973456 | 98516 | None | code33 | Cement Board as per directions of the Engineerin-Charge. | Sqm | 246.75 | 246.75 | 2.88 | False | None | None | False | None | False | 710.64 | 0 | 2973457 | 98516 | None | code34 | chiken mesh | Sqm | 12.6 | 12.6 | 84.64 | False | None | None | False | None | False | 1066.464 | 0 | 2973458 | 98516 | None | code35 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges,handling charges including encasing the pipe around to a depth not lessthan 15 cms with gravel or selected earth available from the excavationetc. complete 75mm(weight of pipe -0.917 kg) | Mtr | 220.5 | 220.5 | 8.0 | False | None | None | False | None | False | 1764.0 | 0 | 2973459 | 98516 | None | code36 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 30.0 | False | None | None | False | None | False | 2100.0 | 0 | 2973460 | 98516 | None | code37 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 | 2973461 | 98516 | None | code38 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. - | Nos | 155.0 | 155.0 | 5.0 | False | None | None | False | None | False | 775.0 | 0 | 2973462 | 98516 | None | code39 | Supplying and fixing 230 volts 20/40 Wats flourecent lamp holder | Nos | 17.0 | 17.0 | 5.0 | False | None | None | False | None | False | 85.0 | 0 | 2973463 | 98516 | None | code40 | Supplying and fixing of slim box fitting, made out of CRCASheet metal body with locking type holder completely wired.Excluding Ballast & Fluorescent Tube.1 x 4' Tube light fitting. | Nos | 324.0 | 324.0 | 2.0 | False | None | None | False | None | False | 648.0 | 0 | 2973464 | 98516 | None | code41 | Supplying capacitor type ceiling fan complete with down road blades shakle regulator capacities., for operation on 230 volts 50 cyeles single phase AC supply conforming to ISI 374-1979 and with double ball bearing sytem and as per technical approved (1200 mm swing) | Nos | 2949.0 | 2949.0 | 2.0 | False | None | None | False | None | False | 5898.0 | 0 | 2973465 | 98516 | None | code42 | Point wiring using Copper wire with switch.2.Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose | Nos | 276.0 | 276.0 | 10.0 | False | None | None | False | None | False | 2760.0 | 0 | 2973466 | 98516 | None | code43 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 386.0 | 386.0 | 8.0 | False | None | None | False | None | False | 3088.0 | 0 | 2973467 | 98516 | None | code44 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 567.0 | 567.0 | 6.0 | False | None | None | False | None | False | 3402.0 | 0 | 2973468 | 98516 | None | code45 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 Way | Point | 143.0 | 143.0 | 5.0 | False | None | None | False | None | False | 715.0 | 0 | 2973469 | 98516 | None | code46 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws. | Sqm | 0.26 | 0.26 | 500.0 | False | None | None | False | None | False | 130.0 | 0 | 2973470 | 98516 | None | code47 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - DP6-32 A DP | Nos | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 | 2973471 | 98516 | None | code48 | Providing and fixing name board | Nos | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 |
| 1709953929000 | 0 | None | None | Buildings | Construction of single class room building at Government modal primary school,ladies at Kudligi town,Construction of single class room at GLPS AD Gudda gollarahatti (Est cost 27.80 lakhs)(2022-23 state sector viveka school)(SC Reserve) | 1161146.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2973472 | 98517 | None | code01 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge | Sqm | 193.2 | 193.2 | 6.84 | False | None | None | False | None | False | 1321.488 | 0 | 2973473 | 98517 | None | code02 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 828.45 | 828.45 | 3.5 | False | None | None | False | None | False | 2899.575 | 0 | 2973474 | 98517 | None | code03 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 387.45 | 387.45 | 16.01 | False | None | None | False | None | False | 6203.0745 | 0 | 2973475 | 98517 | None | code04 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances requiredto complete the work. | Cum | 195.3 | 195.3 | 45.63 | False | None | None | False | None | False | 8911.539 | 0 | 2973476 | 98517 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5831.7 | 5831.7 | 12.04 | False | None | None | False | None | False | 70213.668 | 0 | 2973477 | 98517 | None | code06 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) uptoplinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 4987.5 | 4987.5 | 14.05 | False | None | None | False | None | False | 70074.375 | 0 | 2973478 | 98517 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5619.6 | 5619.6 | 11.8091 | False | None | None | False | None | False | 66362.41836 | 0 | 2973479 | 98517 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 1.61 | False | None | None | False | None | False | 10450.671 | 0 | 2973480 | 98517 | None | code09 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along theexternal perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 99.75 | 99.75 | 5.69 | False | None | None | False | None | False | 567.5775 | 0 | 2973481 | 98517 | None | code09 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. | Sqm | 208.95 | 208.95 | 22.485 | False | None | None | False | None | False | 4698.24075 | 0 | 2973482 | 98517 | None | code10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 214.2 | 214.2 | 76.42 | False | None | None | False | None | False | 16369.164 | 0 | 2973483 | 98517 | None | code11 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Cum | 7295.4 | 7295.4 | 18.8 | False | None | None | False | None | False | 137153.52 | 0 | 2973484 | 98517 | None | code12 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse
aggregates | Cum | 6780.18 | 6780.18 | 6.08 | False | None | None | False | None | False | 41223.4944 | 0 | 2973485 | 98517 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10672.52 | 10672.52 | 6.05 | False | None | None | False | None | False | 64568.746 | 0 | 2973486 | 98517 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6767.71 | 6767.71 | 2.54 | False | None | None | False | None | False | 17189.9834 | 0 | 2973487 | 98517 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10392.48 | 10392.48 | 3.96 | False | None | None | False | None | False | 41154.2208 | 0 | 2973488 | 98517 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9742.95 | 9742.95 | 10.28 | False | None | None | False | None | False | 100157.526 | 0 | 2973489 | 98517 | None | code15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Sqm | 9418.19 | 9418.19 | 0.14 | False | None | None | False | None | False | 1318.5466 | 0 | 2973490 | 98517 | None | code16 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately | Kgs | 96.6 | 96.6 | 2451.96 | False | None | None | False | None | False | 236859.336 | 0 | 2973491 | 98517 | None | code17 | KSRB15-3.10 : Providing 20mm thick cement plaster in single coat with cement mortar 1:3, to stone masonry & concrete surface including rounding off corners wherever required smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. | Sqm | 386.4 | 386.4 | 68.5574 | False | None | None | False | None | False | 26490.57936 | 0 | 2973492 | 98517 | None | code18 | KSRB 15-4.6 : Extra for Providing and mixing waterproofing compound in cement plaster for brick masonry work at one kg per bag or in the proportion recommended by the manufactures, for cement mortar 1:3, 20mm thick cost of materials complete as per specifications. | Sqm | 53.55 | 53.55 | 68.5574 | False | None | None | False | None | False | 3671.24877 | 0 | 2973493 | 98517 | None | code19 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per
specifications and as per directions of Engineer-in-charge | Sqm | 260.4 | 260.4 | 69.36 | False | None | None | False | None | False | 18061.344 | 0 | 2973494 | 98517 | None | code20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 322.35 | 322.35 | 128.04 | False | None | None | False | None | False | 41273.694 | 0 | 2973495 | 98517 | None | code22 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, includingapplying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 3843.0 | 3843.0 | 2.52 | False | None | None | False | None | False | 9684.36 | 0 | 2973496 | 98517 | None | code23 | Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Sqm | 110.25 | 110.25 | 120.96 | False | None | None | False | None | False | 13335.84 | 0 | 2973497 | 98517 | None | code23 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 126.0 | 126.0 | 120.96 | False | None | None | False | None | False | 15240.96 | 0 | 2973498 | 98517 | None | code24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Sqm | 152.25 | 152.25 | 18.9 | False | None | None | False | None | False | 2877.525 | 0 | 2973499 | 98517 | None | code25 | looring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.. | Sqm | 1251.6 | 1251.6 | 50.56 | False | None | None | False | None | False | 63280.896 | 0 | 2973500 | 98517 | None | code26 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 99.75 | 99.75 | 119.92 | False | None | None | False | None | False | 11962.02 | 0 | 2973501 | 98517 | None | code27 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 138.6 | 138.6 | 128.03 | False | None | None | False | None | False | 17744.958 | 0 | 2973502 | 98517 | None | code28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 94.5 | 94.5 | 20.654 | False | None | None | False | None | False | 1951.803 | 0 | 2973503 | 98517 | None | code29 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. | Kgs | 116.55 | 116.55 | 60.0 | False | None | None | False | None | False | 6993.0 | 0 | 2973504 | 98517 | None | code30 | Cement Board as per directions of the Engineerin-Charge. | Sqm | 246.75 | 246.75 | 2.88 | False | None | None | False | None | False | 710.64 | 0 | 2973505 | 98517 | None | code31 | chiken mesh | Sqm | 12.6 | 12.6 | 84.64 | False | None | None | False | None | False | 1066.464 | 0 | 2973506 | 98517 | None | code32 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick | Mtr | 70.0 | 70.0 | 30.0 | False | None | None | False | None | False | 2100.0 | 0 | 2973507 | 98517 | None | code33 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. - 25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 30.0 | False | None | None | False | None | False | 2400.0 | 0 | 2973508 | 98517 | None | code34 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. - | Nos | 155.0 | 155.0 | 5.0 | False | None | None | False | None | False | 775.0 | 0 | 2973509 | 98517 | None | code35 | Supplying and fixing 230 volts 20/40 Wats flourecent lamp holder | Nos | 17.0 | 17.0 | 5.0 | False | None | None | False | None | False | 85.0 | 0 | 2973510 | 98517 | None | code36 | Supplying and fixing of slim box fitting, made out of CRCASheet metal body with locking type holder completely wired.Excluding Ballast & Fluorescent Tube.1 x 4' Tube light fitting. | Nos | 324.0 | 324.0 | 2.0 | False | None | None | False | None | False | 648.0 | 0 | 2973511 | 98517 | None | code37 | Supplying capacitor type ceiling fan complete with down road blades shakle regulator capacities., for operation on 230 volts 50 cyeles single phase AC supply conforming to ISI 374-1979 and with double ball bearing sytem and as per technical approved (1200 mm swing) | Nos | 2949.0 | 2949.0 | 2.0 | False | None | None | False | None | False | 5898.0 | 0 | 2973512 | 98517 | None | code38 | Point wiring using Copper wire with switch.2.Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose | Nos | 276.0 | 276.0 | 10.0 | False | None | None | False | None | False | 2760.0 | 0 | 2973513 | 98517 | None | code39 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 386.0 | 386.0 | 8.0 | False | None | None | False | None | False | 3088.0 | 0 | 2973514 | 98517 | None | code40 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A - Long point above 6Mtr upto 10Mtr from tapping point to out let via switch | Point | 567.0 | 567.0 | 6.0 | False | None | None | False | None | False | 3402.0 | 0 | 2973515 | 98517 | None | code41 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 Way | Point | 143.0 | 143.0 | 5.0 | False | None | None | False | None | False | 715.0 | 0 | 2973516 | 98517 | None | code42 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws. | Sqm | 0.26 | 0.26 | 500.0 | False | None | None | False | None | False | 130.0 | 0 | 2973517 | 98517 | None | code43 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - DP6-32 A DP | Nos | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 | 2973518 | 98517 | None | code44 | Providing and fixing name board | Nos | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 |
|
|
---|