| 2939348 | 97113 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. | Cum | 195.3 | 195.3 | 513.9903 | False | None | None | False | None | False | 100382.30559 | 0 |
| 2939349 | 97113 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. | Cum | 208.95 | 208.95 | 137.3914 | False | None | None | False | None | False | 28707.93303 | 0 |
| 2939350 | 97113 | None | code03 | Providing and injecting chemical emulsion for Pre constructional Anti Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 99.75 | 99.75 | 592.0 | False | None | None | False | None | False | 59052.0 | 0 |
| 2939351 | 97113 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 5466.3 | 5466.3 | 132.8153 | False | None | None | False | None | False | 726008.27439 | 0 |
| 2939352 | 97113 | None | code05 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5820.15 | 5820.15 | 134.4969 | False | None | None | False | None | False | 782792.132535 | 0 |
| 2939353 | 97113 | None | code06 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water, all materials, usage and all other appurtenaces required to complete the work. | Cum | 422.1 | 422.1 | 972.6207 | False | None | None | False | None | False | 410543.19747 | 0 |
| 2939354 | 97113 | None | code07 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7024.5 | 7024.5 | 95.7246 | False | None | None | False | None | False | 672417.4527 | 0 |
| 2939355 | 97113 | None | code08 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 909.3 | 909.3 | 271.705 | False | None | None | False | None | False | 247061.3565 | 0 |
| 2939356 | 97113 | None | code09 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) RCC M20. | Cum | 6240.15 | 6240.15 | 133.3588 | False | None | None | False | None | False | 832178.91582 | 0 |
| 2939357 | 97113 | None | code10 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) RCC M25. | Cum | 6277.95 | 6277.95 | 11.6198 | False | None | None | False | None | False | 72948.52341 | 0 |
| 2939358 | 97113 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) (P.No 17 , I.No 2.5.2) M20 Design Mix Using 25 mm nominal size graded crushed coarse aggregates. | Cum | 6495.3 | 6495.3 | 15.4089 | False | None | None | False | None | False | 100085.42817 | 0 |
| 2939359 | 97113 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) (P.No 17 , I.No 2.5.1) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6491.1 | 6491.1 | 237.733 | False | None | None | False | None | False | 1543148.6763 | 0 |
| 2939360 | 97113 | None | code13 | Providing Thermo Mechanically Treated bars of grade Fe 500D or more Steel reinforcement for R.C.C. work including straightening,cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) '( PWD SR 2021 22, Vol.2 , Page No84, Item No11.32) | Kgs | 96.6 | 96.6 | 32004.0 | False | None | None | False | None | False | 3091586.4 | 0 |
| 2939361 | 97113 | None | code14 | Appendix I Additionalities for Formwork, Centering and Scaffolding Foundation upto Plinth, a. Isolated 8% of the RCC Rate. | Cum | 499.21 | 499.21 | 133.3588 | False | None | None | False | None | False | 66574.046548 | 0 |
| 2939362 | 97113 | None | code15 | Appendix I Additionalities for Formwork, Centering and Scaffolding Plinth beams of buildings 50% of the RCC Rate. | Cum | 3120.08 | 3120.08 | 27.0287 | False | None | None | False | None | False | 84331.706296 | 0 |
| 2939363 | 97113 | None | code16 | Appendix I Additionalities for Formwork, Centering and Scaffolding Columns of buildings 70% of the RCC Rate. | Cum | 4546.71 | 4546.71 | 33.9257 | False | None | None | False | None | False | 154250.319447 | 0 |
| 2939364 | 97113 | None | code17 | Appendix I Additionalities for Formwork, Centering and Scaffolding Lintels and Roof beams 60% of the RCC Rate. | Cum | 3894.66 | 3894.66 | 76.2437 | False | None | None | False | None | False | 296943.288642 | 0 |
| 2939365 | 97113 | None | code18 | Appendix I Additionalities for Formwork, Centering and Scaffolding Roof slab of buildings 50% of the RCC Rate. | Cum | 3245.55 | 3245.55 | 103.3775 | False | None | None | False | None | False | 335516.845125 | 0 |
| 2939366 | 97113 | None | code19 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6014.4 | 6014.4 | 14.2524 | False | None | None | False | None | False | 85719.63456 | 0 |
| 2939367 | 97113 | None | code20 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 326.55 | 326.55 | 1344.6965 | False | None | None | False | None | False | 439110.642075 | 0 |
| 2939368 | 97113 | None | code21 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 338.1 | 338.1 | 444.214 | False | None | None | False | None | False | 150188.7534 | 0 |
| 2939369 | 97113 | None | code22 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 287.7 | 287.7 | 792.3516 | False | None | None | False | None | False | 227959.55532 | 0 |
| 2939370 | 97113 | None | code23 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer in Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. | Sqm | 3013.5 | 3013.5 | 75.177 | False | None | None | False | None | False | 226545.8895 | 0 |
| 2939371 | 97113 | None | code24 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.( PWD SR 2021 22, Vol.2 , Page No62, Item No9.21.1) | Sqm | 1126.65 | 1126.65 | 577.7215 | False | None | None | False | None | False | 650889.927975 | 0 |
| 2939372 | 97113 | None | code25 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1088.85 | 1088.85 | 119.931 | False | None | None | False | None | False | 130586.86935 | 0 |
| 2939373 | 97113 | None | code26 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. | Sqm | 42.0 | 42.0 | 2017.1171 | False | None | None | False | None | False | 84718.9182 | 0 |
| 2939374 | 97113 | None | code27 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in
charge.'( PWD SR 2021 22, Vol.2 , Page No50, Item No8.51) | Sqm | 87.15 | 87.15 | 4154.1652 | False | None | None | False | None | False | 362035.49718 | 0 |
| 2939375 | 97113 | None | code28 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 99.75 | 99.75 | 2017.1171 | False | None | None | False | None | False | 201207.430725 | 0 |
| 2939376 | 97113 | None | code29 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 142.8 | 142.8 | 444.214 | False | None | None | False | None | False | 63433.7592 | 0 |
| 2939377 | 97113 | None | code30 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 137.55 | 137.55 | 1273.5 | False | None | None | False | None | False | 175169.925 | 0 |
| 2939378 | 97113 | None | code31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge | Sqm | 136.5 | 136.5 | 132.76 | False | None | None | False | None | False | 18121.74 | 0 |
| 2939379 | 97113 | None | code32 | Providing Teak wood frames of doors, windows, clerestory windows,ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 247431.45 | 247431.45 | 0.3971 | False | None | None | False | None | False | 98255.028795 | 0 |
| 2939380 | 97113 | None | code33 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 64683.15 | 64683.15 | 0.7448 | False | None | None | False | None | False | 48176.01012 | 0 |
| 2939381 | 97113 | None | code34 | Providing and fixing in position fully panelled Teak wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 9800.7 | 9800.7 | 9.1125 | False | None | None | False | None | False | 89308.87875 | 0 |
| 2939382 | 97113 | None | code35 | Providing and fixing in position fully panelled Teak wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6392.4 | 6392.4 | 3.375 | False | None | None | False | None | False | 21574.35 | 0 |
| 2939383 | 97113 | None | code36 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part I) 1991. from manufacturer complete as per spcification do 30 mm thick Both side teak | Sqm | 3993.15 | 3993.15 | 29.82 | False | None | None | False | None | False | 119075.733 | 0 |
| 2939384 | 97113 | None | code37 | Providing and fixing of doors fixtures. Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Each | 652.05 | 652.05 | 19.0 | False | None | None | False | None | False | 12388.95 | 0 |
| 2939385 | 97113 | None | code38 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass handles with screws etc. complete: | Each | 193.2 | 193.2 | 44.0 | False | None | None | False | None | False | 8500.8 | 0 |
| 2939386 | 97113 | None | code39 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Each | 211.05 | 211.05 | 66.0 | False | None | None | False | None | False | 13929.3 | 0 |
| 2939387 | 97113 | None | code40 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 250x10mm | Each | 353.85 | 353.85 | 44.0 | False | None | None | False | None | False | 15569.4 | 0 |
| 2939388 | 97113 | None | code41 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete | Each | 114.45 | 114.45 | 22.0 | False | None | None | False | None | False | 2517.9 | 0 |
| 2939389 | 97113 | None | code42 | Providing and fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 7602.0 | 7602.0 | 52.2 | False | None | None | False | None | False | 396824.4 | 0 |
| 2939390 | 97113 | None | code43 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 5113.5 | 5113.5 | 1.62 | False | None | None | False | None | False | 8283.87 | 0 |
| 2939391 | 97113 | None | code44 | Providing and fixing stainless steel 304 grade for staircase railings, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 4 Nos of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. | Kgs | 525.0 | 525.0 | 756.16 | False | None | None | False | None | False | 396984.0 | 0 |
| 2939392 | 97113 | None | code45 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 No and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer in Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 622.65 | 622.65 | 28.8 | False | None | None | False | None | False | 17932.32 | 0 |
| 2939393 | 97113 | None | code46 | Supply of solid granite stone all sizes of from gulur, Chikkaballapura District. Quarry to main road with 10km lead and labour charges including hiring charges for chain and pulley block transportation etc., complete as directed by Engineer in charges of work. (Data rate) | Cum | 17400.0 | 17400.0 | 46.5391 | False | None | None | False | None | False | 809780.34 | 0 |
| 2939394 | 97113 | None | code47 | KSRB 5 8.2 : Providing two line dressing to granite stone slab / granite stone masonry as per specifications. KBS 5.1.13 | Sqm | 1495.0 | 1495.0 | 353.2422 | False | None | None | False | None | False | 528097.089 | 0 |
| 2939395 | 97113 | None | code48 | Resetting of Veenering slab stone members of all sizes including conveying from stacked position lifting by chain and pully blocks and setting on its proper position to correct line and plumb and level with all lead, lift and labour charges including hire charges for chain and pully block etc., complete including hire charges of scaffolding materials and as directed by the engineer in charge of work. | Sqm | 860.0 | 860.0 | 16.8 | False | None | None | False | None | False | 14448.0 | 0 |
| 2939396 | 97113 | None | code49 | Providing Dressing to Pillar Base Stone members of all sizes as per the Existing style including conveying from stacked position lifting by chain and pully blocks with all lead, lift and labour charges including hire charges for chain and pully and tools and plants, cutting charges, chiseling charges etc., complete as per directed by the engineer in charge of work. | Sqm | 3270.0 | 3270.0 | 17.808 | False | None | None | False | None | False | 58232.16 | 0 |
| 2939397 | 97113 | None | code50 | Resetting of Pillar Base members of all sizes including conveying from stacked position lifting by chain and pully blocks and setting on its proper position to correct line and plumb and level with all lead, lift and labour charges including hire charges for chain and pully block etc., complete including hire charges of scaffolding materials and as directed by the engineer in charge of work. | Nos | 680.0 | 680.0 | 12.0 | False | None | None | False | None | False | 8160.0 | 0 |
| 2939398 | 97113 | None | code51 | Providing Dressing to Pillar Stone members of all sizes as per the Existing style including conveying from stacked position lifting by chain and pully blocks with all lead, lift and labour charges including hire charges for chain and pully and tools and plants, cutting charges, chiseling charges etc., complete as per directed by the engineer in charge of work. | Sqm | 4370.0 | 4370.0 | 123.728 | False | None | None | False | None | False | 540691.36 | 0 |
| 2939399 | 97113 | None | code52 | Resetting of Pillar Stone members of all sizes including conveying from stacked position lifting by chain and pully blocks and setting on its proper position to correct line and plumb and level with all lead, lift and labour charges including hire charges for chain and pully block etc., complete including hire charges of scaffolding materials and as directed by the engineer in charge of work. | m | 980.0 | 980.0 | 93.6 | False | None | None | False | None | False | 91728.0 | 0 |
| 2939400 | 97113 | None | code53 | Providing Dressing to Capital Stone members of all sizes as per the Existing style including conveying from stacked position lifting by chain and pully blocks with all lead, lift and labour charges including hire charges for chain and pully and tools and plants, cutting charges, chiseling charges etc., complete as per directed by the engineer in charge of work. | Sqm | 5230.0 | 5230.0 | 31.488 | False | None | None | False | None | False | 164682.24 | 0 |
| 2939401 | 97113 | None | code54 | Resetting of Capital Stone members of all sizes including conveying from stacked position lifting by chain and pully blocks and setting on its proper position to correct line and plumb and level with all lead, lift and labour charges including hire charges for chain and pully block etc., complete including hire charges of scaffolding materials and as directed by the engineer in charge of work. | Nos | 925.0 | 925.0 | 40.0 | False | None | None | False | None | False | 37000.0 | 0 |
| 2939402 | 97113 | None | code55 | Resetting of Beam Stone members of all sizes including conveying from stacked position lifting by chain and pully blocks and setting on its proper position to correct line and plumb and level with all lead, lift and labour charges including hire charges for chain and pully block etc., complete including hire charges of scaffolding materials and as directed by the engineer in charge of work. | m | 980.0 | 980.0 | 82.8 | False | None | None | False | None | False | 81144.0 | 0 |
| 2939403 | 97113 | None | code56 | Resetting of Chejja Stone Slab members of all sizes including conveying from stacked position lifting by chain and pully blocks and setting on its proper position to correct line and plumb and level with all lead, lift and labour charges including hire charges for chain and pully block etc., complete including hire charges of scaffolding materials and as directed by the engineer in charge of work. | Sqm | 965.0 | 965.0 | 16.8 | False | None | None | False | None | False | 16212.0 | 0 |
| 2939404 | 97113 | None | code57 | Providing and fixing fire resistant and gas cutting resistant strong room door (thickness of door 12mm and frame 10mm, weight 1100 kg approximate) of size : 4'0 x 7'0 with 2 manual locks operated with 4 keys each. It also has digital lock with 20 nos shooting bolts of 40mm dia each for extra safety all round the shutter (3 nos Top and bottom, 7 nos Left and Right) it is finished with anti rust treatment and nitro cellulose paint for long lasting finish. | Nos | 200000.0 | 200000.0 | 2.0 | False | None | None | False | None | False | 400000.0 | 0 |
| 2939405 | 97113 | None | code58 | Providing groves for plastering including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | m | 100.0 | 100.0 | 518.8 | False | None | None | False | None | False | 51880.0 | 0 |
| 2939406 | 97113 | None | code59 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7091.4 | 7091.4 | 166.9694 | False | None | None | False | None | False | 1184046.80316 | 0 |
| 2939407 | 97113 | None | code60 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 917.95 | 917.95 | 210.203 | False | None | None | False | None | False | 192955.84385 | 0 |
| 2939408 | 97113 | None | code61 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6557.16 | 6557.16 | 15.4089 | False | None | None | False | None | False | 101038.622724 | 0 |
| 2939409 | 97113 | None | code62 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6552.92 | 6552.92 | 165.7246 | False | None | None | False | None | False | 1085980.045832 | 0 |
| 2939410 | 97113 | None | code63 | Providing Thermo Mechanically Treated bars of grade Fe 550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 97.52 | 97.52 | 17595.0 | False | None | None | False | None | False | 1715864.4 | 0 |
| 2939411 | 97113 | None | code64 | Appendix I Additionalities for Formwork, Centering and Scaffolding Columns of buildings 70% of the RCC Rate. | Cum | 4590.01 | 4590.01 | 15.4089 | False | None | None | False | None | False | 70727.005089 | 0 |
| 2939412 | 97113 | None | code65 | Appendix I Additionalities for Formwork, Centering and Scaffolding Lintels and Roof beams 60% of the RCC Rate. | Cum | 3931.75 | 3931.75 | 57.6288 | False | None | None | False | None | False | 226582.0344 | 0 |
| 2939413 | 97113 | None | code66 | Appendix I Additionalities for Formwork, Centering and Scaffolding Roof slab of buildings 50% of the RCC Rate. | Cum | 3276.46 | 3276.46 | 108.0958 | False | None | None | False | None | False | 354171.564868 | 0 |
| 2939414 | 97113 | None | code67 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6071.67 | 6071.67 | 0.6059 | False | None | None | False | None | False | 3678.824853 | 0 |
| 2939415 | 97113 | None | code68 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 329.66 | 329.66 | 1483.2755 | False | None | None | False | None | False | 488976.60133 | 0 |
| 2939416 | 97113 | None | code69 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 341.32 | 341.32 | 662.216 | False | None | None | False | None | False | 226027.56512 | 0 |
| 2939417 | 97113 | None | code70 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 290.44 | 290.44 | 823.8066 | False | None | None | False | None | False | 239266.388904 | 0 |
| 2939418 | 97113 | None | code71 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer in Charge.** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. | Sqm | 3042.2 | 3042.2 | 39.171 | False | None | None | False | None | False | 119166.0162 | 0 |
| 2939419 | 97113 | None | code72 | Providing and laying Vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colors and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. | Sqm | 1137.38 | 1137.38 | 577.3431 | False | None | None | False | None | False | 656658.495078 | 0 |
| 2939420 | 97113 | None | code73 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1099.21 | 1099.21 | 200.232 | False | None | None | False | None | False | 220097.01672 | 0 |
| 2939421 | 97113 | None | code74 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. | Sqm | 42.4 | 42.4 | 2106.8501 | False | None | None | False | None | False | 89330.44424 | 0 |
| 2939422 | 97113 | None | code75 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 87.98 | 87.98 | 4413.9322 | False | None | None | False | None | False | 388337.754956 | 0 |
| 2939423 | 97113 | None | code76 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.7 | 100.7 | 2106.8501 | False | None | None | False | None | False | 212159.80507 | 0 |
| 2939424 | 97113 | None | code77 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 m² over and including
priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 144.16 | 144.16 | 662.216 | False | None | None | False | None | False | 95465.05856 | 0 |
| 2939425 | 97113 | None | code78 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 138.86 | 138.86 | 1008.0 | False | None | None | False | None | False | 139970.88 | 0 |
| 2939426 | 97113 | None | code79 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge | Sqm | 137.8 | 137.8 | 126.528 | False | None | None | False | None | False | 17435.5584 | 0 |
| 2939427 | 97113 | None | code80 | Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 249787.94 | 249787.94 | 0.6005 | False | None | None | False | None | False | 149997.65797 | 0 |
| 2939428 | 97113 | None | code81 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 65299.18 | 65299.18 | 1.1064 | False | None | None | False | None | False | 72247.012752 | 0 |
| 2939429 | 97113 | None | code82 | Providing and fixing in position fully panelled Teak wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 9894.04 | 9894.04 | 15.8925 | False | None | None | False | None | False | 157241.0307 | 0 |
| 2939430 | 97113 | None | code83 | Providing and fixing in position fully glazed for windows shutters with Teak wood stiles and rails of 35mm. thick 75mm wide in single shutters with 4mm thick plain glass fixed with wooden beading including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6453.28 | 6453.28 | 3.375 | False | None | None | False | None | False | 21779.82 | 0 |
| 2939431 | 97113 | None | code84 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part I) 1991. from manufacturer complete as per spcification do 30 mm thick Both side teak | Sqm | 4031.18 | 4031.18 | 46.872 | False | None | None | False | None | False | 188949.46896 | 0 |
| 2939432 | 97113 | None | code85 | Providing and fixing of doors fixtures. Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Each | 652.05 | 652.05 | 27.0 | False | None | None | False | None | False | 17605.35 | 0 |
| 2939433 | 97113 | None | code86 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass handles with screws etc. complete: | Each | 193.2 | 193.2 | 78.0 | False | None | None | False | None | False | 15069.6 | 0 |
| 2939434 | 97113 | None | code87 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Each | 211.05 | 211.05 | 117.0 | False | None | None | False | None | False | 24692.85 | 0 |
| 2939435 | 97113 | None | code88 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 250x10mm | Each | 353.85 | 353.85 | 78.0 | False | None | None | False | None | False | 27600.3 | 0 |
| 2939436 | 97113 | None | code89 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete | Each | 114.45 | 114.45 | 39.0 | False | None | None | False | None | False | 4463.55 | 0 |
| 2939437 | 97113 | None | code90 | Providing and fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 7674.4 | 7674.4 | 36.0 | False | None | None | False | None | False | 276278.4 | 0 |
| 2939438 | 97113 | None | code91 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 5162.2 | 5162.2 | 4.32 | False | None | None | False | None | False | 22300.704 | 0 |
| 2939439 | 97113 | None | code92 | Providing and fixing stainless steel 304 grade for staircase railings, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals, and 4 Nos of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts by drilling concrete etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. | Kgs | 530.0 | 530.0 | 41.98 | False | None | None | False | None | False | 22249.4 | 0 |
| 2939440 | 97113 | None | code93 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 789.7 | 789.7 | 743.3864 | False | None | None | False | None | False | 587052.24008 | 0 |
| 2939441 | 97113 | None | code94 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2138.02 | 2138.02 | 8.3279 | False | None | None | False | None | False | 17805.216758 | 0 |
| 2939442 | 97113 | None | code95 | KSRB 8.6 8 : Providing and fixing on wall surface. 4.0 kg / sq.cm H.D.P.E. rain down water pipes 110mm outer dia. approved make and brand with necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, complete as per specifications. | Mtr | 542.72 | 542.72 | 102.0 | False | None | None | False | None | False | 55357.44 | 0 |
| 2939443 | 97113 | None | code96 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 No and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer in Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 622.65 | 622.65 | 44.16 | False | None | None | False | None | False | 27496.224 | 0 |
| 2939444 | 97113 | None | code97 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7158.3 | 7158.3 | 19.5546 | False | None | None | False | None | False | 139977.69318 | 0 |
| 2939445 | 97113 | None | code98 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6495.3 | 6495.3 | 3.7805 | False | None | None | False | None | False | 24555.48165 | 0 |
| 2939446 | 97113 | None | code99 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6614.74 | 6614.74 | 10.0071 | False | None | None | False | None | False | 66194.364654 | 0 |
| 2939447 | 97113 | None | code100 | Providing Thermo Mechanically Treated bars of grade Fe 550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kgs | 98.44 | 98.44 | 1552.0 | False | None | None | False | None | False | 152778.88 | 0 |
| 2939448 | 97113 | None | code101 | Appendix I Additionalities for Formwork, Centering and Scaffolding Columns of buildings 70% of the RCC Rate. | Cum | 4633.31 | 4633.31 | 3.7805 | False | None | None | False | None | False | 17516.228455 | 0 |
| 2939449 | 97113 | None | code102 | Appendix I Additionalities for Formwork, Centering and Scaffolding Lintels and Roof beams 60% of the RCC Rate. | Cum | 3968.83 | 3968.83 | 4.2276 | False | None | None | False | None | False | 16778.625708 | 0 |
| 2939450 | 97113 | None | code103 | Appendix I Additionalities for Formwork, Centering and Scaffolding Roof slab of buildings 50% of the RCC Rate. | Cum | 3307.37 | 3307.37 | 5.7795 | False | None | None | False | None | False | 19114.944915 | 0 |
| 2939451 | 97113 | None | code104 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 332.77 | 332.77 | 139.802 | False | None | None | False | None | False | 46521.91154 | 0 |
| 2939452 | 97113 | None | code105 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 344.54 | 344.54 | 124.9824 | False | None | None | False | None | False | 43061.436096 | 0 |
| 2939453 | 97113 | None | code106 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. | Sqm | 293.18 | 293.18 | 38.5301 | False | None | None | False | None | False | 11296.254718 | 0 |
| 2939454 | 97113 | None | code107 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1109.59 | 1109.59 | 48.714 | False | None | None | False | None | False | 54052.56726 | 0 |
| 2939455 | 97113 | None | code108 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. | Sqm | 42.8 | 42.8 | 129.6181 | False | None | None | False | None | False | 5547.65468 | 0 |
| 2939456 | 97113 | None | code109 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 88.81 | 88.81 | 307.9502 | False | None | None | False | None | False | 27349.057262 | 0 |
| 2939457 | 97113 | None | code110 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 101.65 | 101.65 | 129.6181 | False | None | None | False | None | False | 13175.679865 | 0 |
| 2939458 | 97113 | None | code111 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 m² over and including
priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. | Sqm | 145.52 | 145.52 | 124.9824 | False | None | None | False | None | False | 18187.438848 | 0 |
| 2939459 | 97113 | None | code112 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. | Kg | 140.17 | 140.17 | 295.0 | False | None | None | False | None | False | 41350.15 | 0 |
| 2939460 | 97113 | None | code113 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge | Sqm | 139.1 | 139.1 | 23.6 | False | None | None | False | None | False | 3282.76 | 0 |
| 2939461 | 97113 | None | code114 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 65915.2 | 65915.2 | 0.0501 | False | None | None | False | None | False | 3302.35152 | 0 |
| 2939462 | 97113 | None | code115 | Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 5429.17 | 5429.17 | 2.07 | False | None | None | False | None | False | 11238.3819 | 0 |
| 2939463 | 97113 | None | code116 | Providing and fixing of doors fixtures. Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. | Each | 664.46 | 664.46 | 1.0 | False | None | None | False | None | False | 664.46 | 0 |
| 2939464 | 97113 | None | code117 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass handles with screws etc. complete: | Each | 196.88 | 196.88 | 2.0 | False | None | None | False | None | False | 393.76 | 0 |
| 2939465 | 97113 | None | code118 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) | Each | 215.07 | 215.07 | 3.0 | False | None | None | False | None | False | 645.21 | 0 |
| 2939466 | 97113 | None | code119 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete. 250x10mm | Each | 360.59 | 360.59 | 2.0 | False | None | None | False | None | False | 721.18 | 0 |
| 2939467 | 97113 | None | code120 | Providing and fixing of doors fixtures. Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete | Each | 116.63 | 116.63 | 1.0 | False | None | None | False | None | False | 116.63 | 0 |
| 2939468 | 97113 | None | code121 | Providing and fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm 2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 7746.8 | 7746.8 | 11.8 | False | None | None | False | None | False | 91412.24 | 0 |
| 2939469 | 97113 | None | code122 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 797.15 | 797.15 | 38.5301 | False | None | None | False | None | False | 30714.269215 | 0 |
| 2939470 | 97113 | None | code123 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 No and then with sand paper of 160/180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs 3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer in Charge. (Final coat to be done in 1 or 2 layers without gap of time.) | Sqm | 622.65 | 622.65 | 9.6 | False | None | None | False | None | False | 5977.44 | 0 |
| 2939471 | 97113 | None | code124 | Ground Floor Electrical Concealed Conduit System Supplying heavy guage PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.. 25 mm dia 2 mm thick(for power circuit) | Mtr | 70.0 | 70.0 | 480.0 | False | None | None | False | None | False | 33600.0 | 0 |
| 2939472 | 97113 | None | code125 | Concealed Conduit System Supplying heavy guage PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.. 32 mm dia 2.5 mm thick for sub mains from MB to MCBDBs | Mtr | 93.0 | 93.0 | 50.0 | False | None | None | False | None | False | 4650.0 | 0 |
| 2939473 | 97113 | None | code126 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall | Mtr | 26.0 | 26.0 | 280.0 | False | None | None | False | None | False | 7280.0 | 0 |
| 2939474 | 97113 | None | code127 | I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.1) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Nos | 386.0 | 386.0 | 142.0 | False | None | None | False | None | False | 54812.0 | 0 |
| 2939475 | 97113 | None | code128 | I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.1) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Nos | 567.0 | 567.0 | 40.0 | False | None | None | False | None | False | 22680.0 | 0 |
| 2939476 | 97113 | None | code129 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Nos | 249.0 | 249.0 | 17.0 | False | None | None | False | None | False | 4233.0 | 0 |
| 2939477 | 97113 | None | code130 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Nos | 249.0 | 249.0 | 17.0 | False | None | None | False | None | False | 4233.0 | 0 |
| 2939478 | 97113 | None | code131 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1 to 3 Way | Nos | 123.0 | 123.0 | 45.0 | False | None | None | False | None | False | 5535.0 | 0 |
| 2939479 | 97113 | None | code132 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4 5 Way | Nos | 138.0 | 138.0 | 5.0 | False | None | None | False | None | False | 690.0 | 0 |
| 2939480 | 97113 | None | code133 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Nos | 212.0 | 212.0 | 5.0 | False | None | None | False | None | False | 1060.0 | 0 |
| 2939481 | 97113 | None | code134 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Nos | 250.0 | 250.0 | 30.0 | False | None | None | False | None | False | 7500.0 | 0 |
| 2939482 | 97113 | None | code135 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10 12 Way | Nos | 325.0 | 325.0 | 18.0 | False | None | None | False | None | False | 5850.0 | 0 |
| 2939483 | 97113 | None | code136 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 18 Way | Nos | 354.0 | 354.0 | 5.0 | False | None | None | False | None | False | 1770.0 | 0 |
| 2939484 | 97113 | None | code137 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Nos | 152.0 | 152.0 | 45.0 | False | None | None | False | None | False | 6840.0 | 0 |
| 2939485 | 97113 | None | code138 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 5 Module | Nos | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
| 2939486 | 97113 | None | code139 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Nos | 244.0 | 244.0 | 5.0 | False | None | None | False | None | False | 1220.0 | 0 |
| 2939487 | 97113 | None | code140 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Nos | 302.0 | 302.0 | 30.0 | False | None | None | False | None | False | 9060.0 | 0 |
| 2939488 | 97113 | None | code141 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 12Module | Nos | 363.0 | 363.0 | 18.0 | False | None | None | False | None | False | 6534.0 | 0 |
| 2939489 | 97113 | None | code142 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16 18 Module | Nos | 403.0 | 403.0 | 5.0 | False | None | None | False | None | False | 2015.0 | 0 |
| 2939490 | 97113 | None | code143 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. | Nos | 88.0 | 88.0 | 210.0 | False | None | None | False | None | False | 18480.0 | 0 |
| 2939491 | 97113 | None | code144 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. | Nos | 162.0 | 162.0 | 125.0 | False | None | None | False | None | False | 20250.0 | 0 |
| 2939492 | 97113 | None | code145 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Nos | 313.0 | 313.0 | 27.0 | False | None | None | False | None | False | 8451.0 | 0 |
| 2939493 | 97113 | None | code146 | Supplying and drawing UTP CAT 6E LAN cable. | Mtr | 34.0 | 34.0 | 1200.0 | False | None | None | False | None | False | 40800.0 | 0 |
| 2939494 | 97113 | None | code147 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 PAIR | Mtr | 19.0 | 19.0 | 800.0 | False | None | None | False | None | False | 15200.0 | 0 |
| 2939495 | 97113 | None | code148 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps lamp holder | Nos | 63.0 | 63.0 | 6.0 | False | None | None | False | None | False | 378.0 | 0 |
| 2939496 | 97113 | None | code149 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 163.0 | 163.0 | 27.0 | False | None | None | False | None | False | 4401.0 | 0 |
| 2939497 | 97113 | None | code150 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32 A SP | No | 523.0 | 523.0 | 64.0 | False | None | None | False | None | False | 33472.0 | 0 |
| 2939498 | 97113 | None | code151 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32 A TPN | No | 1777.0 | 1777.0 | 4.0 | False | None | None | False | None | False | 7108.0 | 0 |
| 2939499 | 97113 | None | code152 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50 63 A TPN | No | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 |
| 2939500 | 97113 | None | code153 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16A 25A 2 pole | No | 4548.0 | 4548.0 | 2.0 | False | None | None | False | None | False | 9096.0 | 0 |
| 2939501 | 97113 | None | code154 | Supplying and fixing regular MCB distribution boards on wall / Wood board / flush mounting using required clA, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way TP and N | No | 4136.0 | 4136.0 | 3.0 | False | None | None | False | None | False | 12408.0 | 0 |
| 2939502 | 97113 | None | code155 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 1400.0 | False | None | None | False | None | False | 36400.0 | 0 |
| 2939503 | 97113 | None | code156 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 2.5 sqmm | Mtr | 40.0 | 40.0 | 3700.0 | False | None | None | False | None | False | 148000.0 | 0 |
| 2939504 | 97113 | None | code157 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 4 sqmm | Mtr | 59.0 | 59.0 | 1800.0 | False | None | None | False | None | False | 106200.0 | 0 |
| 2939505 | 97113 | None | code158 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 10 sqmm | Mtr | 157.0 | 157.0 | 370.0 | False | None | None | False | None | False | 58090.0 | 0 |
| 2939506 | 97113 | None | code159 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 16 sqmm | Mtr | 318.0 | 318.0 | 270.0 | False | None | None | False | None | False | 85860.0 | 0 |
| 2939507 | 97113 | None | code160 | EARTHING: GI Grounding pipe, B Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | Nos | 770.0 | 770.0 | 4.0 | False | None | None | False | None | False | 3080.0 | 0 |
| 2939508 | 97113 | None | code161 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | Nos | 660.0 | 660.0 | 12.0 | False | None | None | False | None | False | 7920.0 | 0 |
| 2939509 | 97113 | None | code162 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Nos | 303.0 | 303.0 | 12.0 | False | None | None | False | None | False | 3636.0 | 0 |
| 2939510 | 97113 | None | code163 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | Nos | 578.0 | 578.0 | 4.0 | False | None | None | False | None | False | 2312.0 | 0 |
| 2939511 | 97113 | None | code164 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip | Mtr | 75.0 | 75.0 | 10.0 | False | None | None | False | None | False | 750.0 | 0 |
| 2939512 | 97113 | None | code165 | LT UG CABLES Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS 3975. 70 Sqmm, 3.5 Core, (18 GI Strips 4 x 0.8 mm) | Km | 423672.0 | 423672.0 | 0.06 | False | None | None | False | None | False | 25420.32 | 0 |
| 2939513 | 97113 | None | code166 | LT UG CABLES Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS 3975. 95 Sqmm, 3.5 Core, (18 GI Strips 4 x 0.8 mm) | Km | 514040.0 | 514040.0 | 0.08 | False | None | None | False | None | False | 41123.2 | 0 |
| 2939514 | 97113 | None | code167 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. As per BESCOM Part IV 11 kV Labour CSR 2021 22, Page No8, Item No29.02 In soil Ordinary soil | m | 260.0 | 260.0 | 140.0 | False | None | None | False | None | False | 36400.0 | 0 |
| 2939515 | 97113 | None | code168 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. (2.5 to 25 Sqmm)6 sqmm to 16 sqmm | Km | 16159.0 | 16159.0 | 0.14 | False | None | None | False | None | False | 2262.26 | 0 |
| 2939516 | 97113 | None | code169 | MAIN PANEL BOARD Supply and Installation / Fixing / Provision of Outdoor type GI Metal sheet panel board 18 SWG Powder coated with door enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having | Set | 168000.0 | 168000.0 | 1.0 | False | None | None | False | None | False | 168000.0 | 0 |
| 2939517 | 97113 | None | code170 | ONLINE UPS PANEL BOARD Supply and Installation / Fixing / Provision of Outdoor type GI Metal sheet panel board 18 SWG Powder coated with door enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having | Set | 48000.0 | 48000.0 | 1.0 | False | None | None | False | None | False | 48000.0 | 0 |
| 2939518 | 97113 | None | code171 | First Floor Electrical Concealed Conduit System Supplying heavy guage PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.. 25 mm dia 2 mm thick(for power circuit) | Mtr | 70.0 | 70.0 | 380.0 | False | None | None | False | None | False | 26600.0 | 0 |
| 2939519 | 97113 | None | code172 | First Floor Electrical Concealed Conduit System Supplying heavy guage PVC condiuit pipe ……mm dia ......mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.. 32 mm dia 2.5 mm thick for sub mains from MB to MCBDBs | Mtr | 93.0 | 93.0 | 50.0 | False | None | None | False | None | False | 4650.0 | 0 |
| 2939520 | 97113 | None | code173 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall | Mtr | 26.0 | 26.0 | 210.0 | False | None | None | False | None | False | 5460.0 | 0 |
| 2939521 | 97113 | None | code174 | I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.1) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch | Nos | 386.0 | 386.0 | 118.0 | False | None | None | False | None | False | 45548.0 | 0 |
| 2939522 | 97113 | None | code175 | I. Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC INSUATED TO 2x1.5Sq.mm Cable confirming to the GTP with a 6Amps flush type SP Control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose lenght in a wood/PVC round block. complete for each outlet.(5/2.1) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Nos | 567.0 | 567.0 | 60.0 | False | None | None | False | None | False | 34020.0 | 0 |
| 2939523 | 97113 | None | code176 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switch | Nos | 249.0 | 249.0 | 8.0 | False | None | None | False | None | False | 1992.0 | 0 |
| 2939524 | 97113 | None | code177 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socket | Nos | 249.0 | 249.0 | 8.0 | False | None | None | False | None | False | 1992.0 | 0 |
| 2939525 | 97113 | None | code178 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1 to 3 Way | Nos | 123.0 | 123.0 | 43.0 | False | None | None | False | None | False | 5289.0 | 0 |
| 2939526 | 97113 | None | code179 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4 5 Way | Nos | 138.0 | 138.0 | 3.0 | False | None | None | False | None | False | 414.0 | 0 |
| 2939527 | 97113 | None | code180 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way | Nos | 212.0 | 212.0 | 2.0 | False | None | None | False | None | False | 424.0 | 0 |
| 2939528 | 97113 | None | code181 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Nos | 250.0 | 250.0 | 22.0 | False | None | None | False | None | False | 5500.0 | 0 |
| 2939529 | 97113 | None | code182 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10 12 Way | Nos | 325.0 | 325.0 | 10.0 | False | None | None | False | None | False | 3250.0 | 0 |
| 2939530 | 97113 | None | code183 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 18 Way | Nos | 354.0 | 354.0 | 2.0 | False | None | None | False | None | False | 708.0 | 0 |
| 2939531 | 97113 | None | code184 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Nos | 152.0 | 152.0 | 43.0 | False | None | None | False | None | False | 6536.0 | 0 |
| 2939532 | 97113 | None | code185 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 5 Module | Nos | 175.0 | 175.0 | 3.0 | False | None | None | False | None | False | 525.0 | 0 |
| 2939533 | 97113 | None | code186 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Nos | 244.0 | 244.0 | 2.0 | False | None | None | False | None | False | 488.0 | 0 |
| 2939534 | 97113 | None | code187 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Nos | 302.0 | 302.0 | 22.0 | False | None | None | False | None | False | 6644.0 | 0 |
| 2939535 | 97113 | None | code188 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 12Module | Nos | 363.0 | 363.0 | 10.0 | False | None | None | False | None | False | 3630.0 | 0 |
| 2939536 | 97113 | None | code189 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16 18 Module | Nos | 403.0 | 403.0 | 2.0 | False | None | None | False | None | False | 806.0 | 0 |
| 2939537 | 97113 | None | code190 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. | Nos | 88.0 | 88.0 | 225.0 | False | None | None | False | None | False | 19800.0 | 0 |
| 2939538 | 97113 | None | code191 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socket. | Nos | 162.0 | 162.0 | 65.0 | False | None | None | False | None | False | 10530.0 | 0 |
| 2939539 | 97113 | None | code192 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator. | Nos | 313.0 | 313.0 | 16.0 | False | None | None | False | None | False | 5008.0 | 0 |
| 2939540 | 97113 | None | code193 | Supplying and drawing UTP CAT 6E LAN cable. | Mtr | 34.0 | 34.0 | 900.0 | False | None | None | False | None | False | 30600.0 | 0 |
| 2939541 | 97113 | None | code194 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 PAIR | Mtr | 19.0 | 19.0 | 900.0 | False | None | None | False | None | False | 17100.0 | 0 |
| 2939542 | 97113 | None | code195 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps lamp holder | Nos | 63.0 | 63.0 | 21.0 | False | None | None | False | None | False | 1323.0 | 0 |
| 2939543 | 97113 | None | code196 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 163.0 | 163.0 | 16.0 | False | None | None | False | None | False | 2608.0 | 0 |
| 2939544 | 97113 | None | code197 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32 A SP | No | 523.0 | 523.0 | 50.0 | False | None | None | False | None | False | 26150.0 | 0 |
| 2939545 | 97113 | None | code198 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6 32 A TPN | No | 1777.0 | 1777.0 | 4.0 | False | None | None | False | None | False | 7108.0 | 0 |
| 2939546 | 97113 | None | code199 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50 63 A TPN | No | 1103.0 | 1103.0 | 2.0 | False | None | None | False | None | False | 2206.0 | 0 |
| 2939547 | 97113 | None | code200 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board. 16A 25A 2 pole | No | 4548.0 | 4548.0 | 2.0 | False | None | None | False | None | False | 9096.0 | 0 |
| 2939548 | 97113 | None | code201 | Supplying and fixing regular MCB distribution boards on wall / Wood board / flush mounting using required clA, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way TP and N | No | 4136.0 | 4136.0 | 3.0 | False | None | None | False | None | False | 12408.0 | 0 |
| 2939549 | 97113 | None | code202 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 1.5 sqmm | Mtr | 26.0 | 26.0 | 1800.0 | False | None | None | False | None | False | 46800.0 | 0 |
| 2939550 | 97113 | None | code203 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 2.5 sqmm | Mtr | 40.0 | 40.0 | 3200.0 | False | None | None | False | None | False | 128000.0 | 0 |
| 2939551 | 97113 | None | code204 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 4 sqmm | Mtr | 59.0 | 59.0 | 1800.0 | False | None | None | False | None | False | 106200.0 | 0 |
| 2939552 | 97113 | None | code205 | DIESEL GENERATOR SET Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per BS 5514 ISO 125 kVA 100 Kw3046 ISO 8528 and IS 1002 ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin on lube oil filter, Spin on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer Hospital grade, Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10 for one hour in 12 hours of operationCapacity of Fuel Tank: Fuel tank suitable for 8 hours of operation Alternator Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS IEC 60034 1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an Current 1 ph or 3 ph, kVA 3 ph and total, Frequency, Provide Engine Data, Starting battery Fluid drains for lube oil and DIESEL GENERATOR SET fuel, Fuel fillingspecification as per detailed estimate | Nos | 924715.0 | 924715.0 | 1.0 | False | None | None | False | None | False | 924715.0 | 0 |
| 2939553 | 97113 | None | code206 | EARTHING: GI Grounding pipe, B Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | Nos | 770.0 | 770.0 | 4.0 | False | None | None | False | None | False | 3080.0 | 0 |
| 2939554 | 97113 | None | code207 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | Nos | 660.0 | 660.0 | 12.0 | False | None | None | False | None | False | 7920.0 | 0 |
| 2939555 | 97113 | None | code208 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Nos | 303.0 | 303.0 | 12.0 | False | None | None | False | None | False | 3636.0 | 0 |
| 2939556 | 97113 | None | code209 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | Nos | 578.0 | 578.0 | 4.0 | False | None | None | False | None | False | 2312.0 | 0 |
| 2939557 | 97113 | None | code210 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip | Mtr | 75.0 | 75.0 | 40.0 | False | None | None | False | None | False | 3000.0 | 0 |
| 2939558 | 97113 | None | code211 | LT UG CABLES Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS 3975. 70 Sqmm, 3.5 Core, (18 GI Strips 4 x 0.8 mm) | Km | 423672.0 | 423672.0 | 0.1 | False | None | None | False | None | False | 42367.2 | 0 |
| 2939559 | 97113 | None | code212 | Digging of trench of 0.6m deep 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete. As per BESCOM Part IV 11 kV Labour CSR 2021 22, Page No9, Item No31.05 In soil hard | m | 102.0 | 102.0 | 100.0 | False | None | None | False | None | False | 10200.0 | 0 |
| 2939560 | 97113 | None | code213 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. (2.5 to 25 Sqmm)6 sqmm to 16 sqmm | Km | 16159.0 | 16159.0 | 0.1 | False | None | None | False | None | False | 1615.9 | 0 |
| 2939561 | 97113 | None | code214 | Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/ Frequency/ kVA, Running hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.62.5KVA to 125 KVA | Nos | 107525.0 | 107525.0 | 1.0 | False | None | None | False | None | False | 107525.0 | 0 |
| 2939562 | 97113 | None | code215 | Supplying and Erection for Gescom Line Supports (Pole) RCC Pole 9 Mtr Long, 145 Kg WL
(Dwg No BESCOM/GM/QSandS/02 Dtd 24.11.2018) as per IS 785 | Nos | 7153.0 | 7153.0 | 3.0 | False | None | None | False | None | False | 21459.0 | 0 |
| 2939563 | 97113 | None | code216 | Digging of Pit Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing.. Hard Soil | Nos | 1638.0 | 1638.0 | 3.0 | False | None | None | False | None | False | 4914.0 | 0 |
| 2939564 | 97113 | None | code217 | Concrete works…. Providing cement concrete to Poles and Guy sets with material and labour including necessary curing etc., complete (cost does not include excavation) B) Pole Concreting with CC 1:2:4 (without coping). a) 9 Mtr support (650x500x1700mm) | Nos | 3158.0 | 3158.0 | 3.0 | False | None | None | False | None | False | 9474.0 | 0 |
| 2939565 | 97113 | None | code218 | Erection of Poles Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth | Nos | 3158.0 | 3158.0 | 3.0 | False | None | None | False | None | False | 9474.0 | 0 |
| 2939566 | 97113 | None | code219 | 11 kV, Horizontal Cross Arm Mild Steel (MS)
(Dwg No BESCOM/GM/QSandS/04 Dtd 24.11.2018) 279020 No 251 390 | Nos | 390.0 | 390.0 | 2.0 | False | None | None | False | None | False | 780.0 | 0 |
| 2939567 | 97113 | None | code220 | Fixing of Cross Arm, Single Top Support, EG Stirrup, Anticlimbing Device, Guy Set, Guarding etc., Fixing of 4 Pin cross arm with Insulator and Braces fixing | Nos | 122.0 | 122.0 | 4.0 | False | None | None | False | None | False | 488.0 | 0 |
| 2939568 | 97113 | None | code221 | HT ST Support 50x8 mm Flat MS (Dwg No BESCOM/GM/QSandS/04 Dtd 24.11.2018 | Nos | 96.0 | 96.0 | 2.0 | False | None | None | False | None | False | 192.0 | 0 |
| 2939569 | 97113 | None | code222 | HT ST Support 50x6 mm Flat GI | Nos | 125.0 | 125.0 | 2.0 | False | None | None | False | None | False | 250.0 | 0 |
| 2939570 | 97113 | None | code223 | Spiral Earth Electrode | Nos | 567.0 | 567.0 | 4.0 | False | None | None | False | None | False | 2268.0 | 0 |
| 2939571 | 97113 | None | code224 | Clamps A Type (MS and GI) as per IS 1977 RCC Pole Clamp MS (Dwg No BESCOM/GM/QSandS/30 Dtd 24.11.2018) | Nos | 89.0 | 89.0 | 2.0 | False | None | None | False | None | False | 178.0 | 0 |
| 2939572 | 97113 | None | code225 | Insulator as per IS 1445 for Ceremic, IS 7935 for GI Pin, IEC 61109 for Polymeric DISC Insulator 45 kN Porcelain | Nos | 470.0 | 470.0 | 6.0 | False | None | None | False | None | False | 2820.0 | 0 |
| 2939573 | 97113 | None | code226 | ACSR Conductor as per IS 398 (Part 2/1996) Rabbit ACSR (6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM | Km | 61515.0 | 61515.0 | 0.3 | False | None | None | False | None | False | 18454.5 | 0 |
| 2939574 | 97113 | None | code227 | Stringing of Conductor for Rabbit ACSR | Km | 3299.0 | 3299.0 | 0.3 | False | None | None | False | None | False | 989.7 | 0 |
| 2939575 | 97113 | None | code228 | Guy Wire and GI Wire as per IS 2141 10 SWG GI Wire (3.251 mm Dia), Std Wt: 128 Kg/KM | MT | 82136.0 | 82136.0 | 0.003 | False | None | None | False | None | False | 246.408 | 0 |
| 2939576 | 97113 | None | code229 | Digging of Pit for GUY SET Hard Soil | Nos | 631.0 | 631.0 | 1.0 | False | None | None | False | None | False | 631.0 | 0 |
| 2939577 | 97113 | None | code230 | Distribution Transformer 3 Phase, 11kV/433V Amorphous Core with Oil as per IS 1180 (Part 1): 2014 100 kVA, Aluminium Wdg, Star 2 (5 Star) | Nos | 216100.0 | 216100.0 | 1.0 | False | None | None | False | None | False | 216100.0 | 0 |
| 2939578 | 97113 | None | code231 | Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing For 100 to 250 kVA | Nos | 4405.0 | 4405.0 | 1.0 | False | None | None | False | None | False | 4405.0 | 0 |
| 2939579 | 97113 | None | code232 | Erection of Transformer and Structures Erection of 100 kVA Transformer | Nos | 1151.0 | 1151.0 | 1.0 | False | None | None | False | None | False | 1151.0 | 0 |
| 2939580 | 97113 | None | code233 | LT Protection LT Protection Kit (Dwg No BESCOM/GM/QSandS/10 Dtd 24.11.2018) | Nos | 1915.0 | 1915.0 | 1.0 | False | None | None | False | None | False | 1915.0 | 0 |
| 2939581 | 97113 | None | code234 | LT Distribution Box as per IS 13947 Part 1and2 LT Distribution Box for 100 kVA DTC with MCCB's (Sheet Metal) (Dwg No BESCOM/GM/QSandS/58 Dtd 24.11.2018) | Set | 22809.0 | 22809.0 | 1.0 | False | None | None | False | None | False | 22809.0 | 0 |
| 2939582 | 97113 | None | code235 | Distribution Box for DTC Fixing LT Distribution box for 100/250/500 kVA DTC (Excluding wiring | Nos | 576.0 | 576.0 | 1.0 | False | None | None | False | None | False | 576.0 | 0 |
| 2939583 | 97113 | None | code236 | Lightning Arrester as per IEC 60099 4 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR (Dwg No BESCOM/GM/QSandS/26 Dtd 24.10.2007) | Nos | 975.0 | 975.0 | 1.0 | False | None | None | False | None | False | 975.0 | 0 |
| 2939584 | 97113 | None | code237 | Fixing of DOLO, GOS, LA, Fuse Board, Service Mains, Spacer, Insulator Etc. Fixing of 3 Nos Lightning Arrestor including wiring | Nos | 805.0 | 805.0 | 1.0 | False | None | None | False | None | False | 805.0 | 0 |
| 2939585 | 97113 | None | code238 | Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS 1977 For 25/63/100 kVA 4/5 Star Rated Transformer on
PSCC Pole 9 Mtr Long, 300 Kg WL GI | Set | 25186.0 | 25186.0 | 1.0 | False | None | None | False | None | False | 25186.0 | 0 |
| 2939586 | 97113 | None | code239 | GOS as per IS 9921, IS 1977 H Frame Set for fixing 11 kV, 200 Amps Single Break GOS (For DP structure for providing New GOS for sectionalisation) MS | Set | 4543.0 | 4543.0 | 1.0 | False | None | None | False | None | False | 4543.0 | 0 |
| 2939587 | 97113 | None | code240 | Insulated GOS Operating Rods | Nos | 433.0 | 433.0 | 1.0 | False | None | None | False | None | False | 433.0 | 0 |
| 2939588 | 97113 | None | code241 | Fixing of DOLO, GOS, LA, Fuse Board, Service Mains, Spacer, Insulator Etc. Fixing of GOS including wiring (11 kV Single Break 200 Amps) | Nos | 805.0 | 805.0 | 1.0 | False | None | None | False | None | False | 805.0 | 0 |
| 2939589 | 97113 | None | code242 | DOLO Cutout as per IS 9385, Part 1 to 3 11 kV, DOLO Cutout Conventional to Erstwhile KEB Specification | Set | 5672.0 | 5672.0 | 1.0 | False | None | None | False | None | False | 5672.0 | 0 |
| 2939590 | 97113 | None | code243 | Fixing of DOLO, GOS, LA, Fuse Board, Service Mains, Spacer, Insulator Etc. Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring | Nos | 178.0 | 178.0 | 1.0 | False | None | None | False | None | False | 178.0 | 0 |
| 2939591 | 97113 | None | code244 | DP Set (2 Pole Strucrure Kit) as per IS 1977 For RCC Pole 9 Mtr Long, 145KG WL/PSCC Pole 9 Mtr Long, 300Kg WL MS (Dwg No BESCOM/GM/QSandS/35 and 63 Dtd 24.11.2018) | Set | 6712.0 | 6712.0 | 1.0 | False | None | None | False | None | False | 6712.0 | 0 |
| 2939592 | 97113 | None | code245 | LT Line Spacer For 4 Wire | Nos | 70.0 | 70.0 | 1.0 | False | None | None | False | None | False | 70.0 | 0 |
| 2939593 | 97113 | None | code246 | EARTHING: GI Grounding pipe, B Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg | Nos | 770.0 | 770.0 | 7.0 | False | None | None | False | None | False | 5390.0 | 0 |
| 2939594 | 97113 | None | code247 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each | Nos | 660.0 | 660.0 | 21.0 | False | None | None | False | None | False | 13860.0 | 0 |
| 2939595 | 97113 | None | code248 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag | Nos | 303.0 | 303.0 | 21.0 | False | None | None | False | None | False | 6363.0 | 0 |
| 2939596 | 97113 | None | code249 | Digging of Pit for providing GI Pipe type Earthing Ordinary Soil | Nos | 578.0 | 578.0 | 7.0 | False | None | None | False | None | False | 4046.0 | 0 |
| 2939597 | 97113 | None | code250 | Measuring Equipment LT 3 Phase, 4 Wire, CT Operated DLMS Complaint ETV Meter 5A, class 0.5sAccuracy (Used for 25 HP/18KW and Above Installations, DTC Metering) | Nos | 3312.0 | 3312.0 | 2.0 | False | None | None | False | None | False | 6624.0 | 0 |
| 2939598 | 97113 | None | code251 | Fixing Metering Box for housing the ETV Meter 3 Phase 4 Wire along with CT's, Meter and wiring for DTC 100 kVA TC | Nos | 1449.0 | 1449.0 | 2.0 | False | None | None | False | None | False | 2898.0 | 0 |
| 2939599 | 97113 | None | code252 | Meter Protection/Tamper Proof Box (MS) for LT Installations 25 HP and above Meter Protection/Tamper Proof box with busbar for LT 3 Ph with CT Ratio 50/5A, 1.0 Accuracy Class | Nos | 6156.0 | 6156.0 | 2.0 | False | None | None | False | None | False | 12312.0 | 0 |
| 2939600 | 97113 | None | code253 | HT Metering Equipment (LBS) 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT and 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem and 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No BESCOM/GM/QSandS/ Dtd 24.11.2018) | Nos | 244780.0 | 244780.0 | 1.0 | False | None | None | False | None | False | 244780.0 | 0 |
| 2939601 | 97113 | None | code254 | LT UG CABLES Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS 3975. 95 Sqmm, 3.5 Core, (18 GI Strips 4 x 0.8 mm) | Km | 514040.0 | 514040.0 | 0.08 | False | None | None | False | None | False | 41123.2 | 0 |
| 2939602 | 97113 | None | code255 | HT UG CABLES 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS 7098 (Part 2) Armouring wires dia and Resistivity as per IS 3975 95 Sqmm, (54 GI Wires 2.5 mm Dia) | Km | 1115615.0 | 1115615.0 | 0.06 | False | None | None | False | None | False | 66936.9 | 0 |
| 2939603 | 97113 | None | code256 | Digging of trench of 0.6m deep 0.50 mtr wide refilling the trench to the required ground level and consolidating etc complete As per BESCOM Part IV 11 kV Labour CSR 2021 22 Page No 9 Item No 31 05 In soil hard | m | 102.0 | 102.0 | 100.0 | False | None | None | False | None | False | 10200.0 | 0 |
| 2939604 | 97113 | None | code257 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. 2.5 to 25 Sqmm 6 sqmm to 16 sqmm | Km | 16159.0 | 16159.0 | 0.08 | False | None | None | False | None | False | 1292.72 | 0 |
| 2939605 | 97113 | None | code258 | GESCOM Supervising charges | LS | 22845.0 | 22845.0 | 1.0 | False | None | None | False | None | False | 22845.0 | 0 |
| 2939606 | 97113 | None | code259 | Sanitary Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usageand other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m | Cum | 493.5 | 493.5 | 151.2 | False | None | None | False | None | False | 74617.2 | 0 |
| 2939607 | 97113 | None | code260 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass,including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern | Unit | 6959.4 | 6959.4 | 4.0 | False | None | None | False | None | False | 27837.6 | 0 |
| 2939608 | 97113 | None | code261 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 5255.25 | 5255.25 | 10.0 | False | None | None | False | None | False | 52552.5 | 0 |
| 2939609 | 97113 | None | code262 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Each | 4458.3 | 4458.3 | 3.0 | False | None | None | False | None | False | 13374.9 | 0 |
| 2939610 | 97113 | None | code263 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover.. | No | 4057.2 | 4057.2 | 8.0 | False | None | None | False | None | False | 32457.6 | 0 |
| 2939611 | 97113 | None | code264 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame and cover.. | No | 5225.85 | 5225.85 | 8.0 | False | None | None | False | None | False | 41806.8 | 0 |
| 2939612 | 97113 | None | code265 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. Pipes of SN4, 110mm dia. | Mtr | 284.55 | 284.55 | 200.0 | False | None | None | False | None | False | 56910.0 | 0 |
| 2939613 | 97113 | None | code266 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. Pipes of SN4, 160mm dia. | Mtr | 583.8 | 583.8 | 120.0 | False | None | None | False | None | False | 70056.0 | 0 |
| 2939614 | 97113 | None | code267 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. Pipes of SN4, 200mm dia. | Mtr | 849.45 | 849.45 | 150.0 | False | None | None | False | None | False | 127417.5 | 0 |
| 2939615 | 97113 | None | code268 | Providing and fixing 100 mm sand cast Iron grating for gully trap | No | 215.25 | 215.25 | 22.0 | False | None | None | False | None | False | 4735.5 | 0 |
| 2939616 | 97113 | None | code269 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 3778.95 | 3778.95 | 9.0 | False | None | None | False | None | False | 34010.55 | 0 |
| 2939617 | 97113 | None | code270 | KSRB 13 11.1 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications.(For 1000 litre capacity) | No | 7169.4 | 7169.4 | 10.0 | False | None | None | False | None | False | 71694.0 | 0 |
| 2939618 | 97113 | None | code271 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. | Each | 707.7 | 707.7 | 22.0 | False | None | None | False | None | False | 15569.4 | 0 |
| 2939619 | 97113 | None | code272 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia, 10 kg/sqcm and class 5 | Mtr | 67.2 | 67.2 | 200.0 | False | None | None | False | None | False | 13440.0 | 0 |
| 2939620 | 97113 | None | code273 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 25mm dia PVC couplers | Nos | 13.65 | 13.65 | 25.0 | False | None | None | False | None | False | 341.25 | 0 |
| 2939621 | 97113 | None | code274 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 32mm dia PVC couplers | Nos | 17.85 | 17.85 | 20.0 | False | None | None | False | None | False | 357.0 | 0 |
| 2939622 | 97113 | None | code275 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 50mm dia PVC couplers | Nos | 30.45 | 30.45 | 40.0 | False | None | None | False | None | False | 1218.0 | 0 |
| 2939623 | 97113 | None | code276 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 110mm dia PVC couplers | Nos | 186.9 | 186.9 | 15.0 | False | None | None | False | None | False | 2803.5 | 0 |
| 2939624 | 97113 | None | code277 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 160mm dia PVC couplers | Nos | 366.45 | 366.45 | 10.0 | False | None | None | False | None | False | 3664.5 | 0 |
| 2939625 | 97113 | None | code278 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 200mm dia PVC couplers | Nos | 517.65 | 517.65 | 15.0 | False | None | None | False | None | False | 7764.75 | 0 |
| 2939626 | 97113 | None | code279 | Supply and delivery at site special moulded variety PVC Tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 25mm dia PVC Tee | Nos | 23.1 | 23.1 | 30.0 | False | None | None | False | None | False | 693.0 | 0 |
| 2939627 | 97113 | None | code280 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 32mm dia PVC Tee | Nos | 34.65 | 34.65 | 40.0 | False | None | None | False | None | False | 1386.0 | 0 |
| 2939628 | 97113 | None | code281 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 50mm dia PVC Tee | Nos | 67.2 | 67.2 | 38.0 | False | None | None | False | None | False | 2553.6 | 0 |
| 2939629 | 97113 | None | code282 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 110mm dia PVC Tee | Nos | 275.1 | 275.1 | 20.0 | False | None | None | False | None | False | 5502.0 | 0 |
| 2939630 | 97113 | None | code283 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 160mm dia PVC Tee | Nos | 510.3 | 510.3 | 6.0 | False | None | None | False | None | False | 3061.8 | 0 |
| 2939631 | 97113 | None | code284 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 200mm dia PVC Tee | Nos | 758.1 | 758.1 | 6.0 | False | None | None | False | None | False | 4548.6 | 0 |
| 2939632 | 97113 | None | code285 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25mm dia PVC elbows | Nos | 17.85 | 17.85 | 20.0 | False | None | None | False | None | False | 357.0 | 0 |
| 2939633 | 97113 | None | code286 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 32mm dia PVC elbows | Nos | 23.1 | 23.1 | 25.0 | False | None | None | False | None | False | 577.5 | 0 |
| 2939634 | 97113 | None | code287 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 50mm dia PVC elbows | Nos | 72.45 | 72.45 | 42.0 | False | None | None | False | None | False | 3042.9 | 0 |
| 2939635 | 97113 | None | code288 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110mm dia PVC elbows | Nos | 330.75 | 330.75 | 25.0 | False | None | None | False | None | False | 8268.75 | 0 |
| 2939636 | 97113 | None | code289 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 160mm dia PVC elbows | Nos | 515.55 | 515.55 | 12.0 | False | None | None | False | None | False | 6186.6 | 0 |
| 2939637 | 97113 | None | code290 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 200mm dia PVC elbows | Nos | 645.75 | 645.75 | 15.0 | False | None | None | False | None | False | 9686.25 | 0 |
| 2939638 | 97113 | None | code291 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 25mm dia, 10 kg/sqcm and class 5 | Mtr | 49.35 | 49.35 | 100.0 | False | None | None | False | None | False | 4935.0 | 0 |
| 2939639 | 97113 | None | code292 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 50mm dia, 10 kg/sqcm and class 5 | Mtr | 100.8 | 100.8 | 375.0 | False | None | None | False | None | False | 37800.0 | 0 |
| 2939640 | 97113 | None | code293 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore | Each | 403.2 | 403.2 | 4.0 | False | None | None | False | None | False | 1612.8 | 0 |
| 2939641 | 97113 | None | code294 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :50 mm nominal bore | Each | 875.7 | 875.7 | 2.0 | False | None | None | False | None | False | 1751.4 | 0 |
| 2939642 | 97113 | None | code295 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore | Each | 605.85 | 605.85 | 2.0 | False | None | None | False | None | False | 1211.7 | 0 |
| 2939643 | 97113 | None | code296 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm | Each | 1549.8 | 1549.8 | 9.0 | False | None | None | False | None | False | 13948.2 | 0 |
| 2939644 | 97113 | None | code297 | 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 399.0 | 399.0 | 13.0 | False | None | None | False | None | False | 5187.0 | 0 |
| 2939645 | 97113 | None | code298 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality and make and as per the direction of Engineer in charge. | Each | 1004.85 | 1004.85 | 9.0 | False | None | None | False | None | False | 9043.65 | 0 |
| 2939646 | 97113 | None | code299 | Sinking of Borewell (Separate Estimate Enclosed) Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 0.00 to 50 Mtrs | Mtr | 304.5 | 304.5 | 50.0 | False | None | None | False | None | False | 15225.0 | 0 |
| 2939647 | 97113 | None | code300 | Sinking of Borewell (Separate Estimate Enclosed) Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 50.00 to 100.00 Mtrs | Mtr | 382.2 | 382.2 | 50.0 | False | None | None | False | None | False | 19110.0 | 0 |
| 2939648 | 97113 | None | code301 | Sinking of Borewell (Separate Estimate Enclosed) Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG and above 1100 CMF and above in all strata including over burdern. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 100.00 to 150.00 Mtrs | Mtr | 406.35 | 406.35 | 50.0 | False | None | None | False | None | False | 20317.5 | 0 |
| 2939649 | 97113 | None | code302 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270 2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387 1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5 7m both ends.threaded conforming to IS 554 1985 one end fixed with socket conforming to IS 4270 2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar Medium duty. | Mtr | 2029.65 | 2029.65 | 12.0 | False | None | None | False | None | False | 24355.8 | 0 |
| 2939650 | 97113 | None | code303 | Providing and fixing MS casing collars as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part II) 1982 with all amendments | Each | 157.5 | 157.5 | 1.0 | False | None | None | False | None | False | 157.5 | 0 |
| 2939651 | 97113 | None | code304 | Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Each | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 |
| 2939652 | 97113 | None | code305 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1and2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M 15%, b) Above 30 M 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/ is to be deducted for Dry Borewell towards yield test. | Each | 5398.05 | 5398.05 | 1.0 | False | None | None | False | None | False | 5398.05 | 0 |
| 2939653 | 97113 | None | code306 | Providing Pumping Machinery to Borewell (Separate Estimate Enclosed) Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. (2.0HP/1.5kV,18 STG.) | Each | 21936.6 | 21936.6 | 1.0 | False | None | None | False | None | False | 21936.6 | 0 |
| 2939654 | 97113 | None | code307 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) | Each | 3202.5 | 3202.5 | 1.0 | False | None | None | False | None | False | 3202.5 | 0 |
| 2939655 | 97113 | None | code308 | Supply and delivery at site 50mm(2) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | Mtr | 603.75 | 603.75 | 90.0 | False | None | None | False | None | False | 54337.5 | 0 |
| 2939656 | 97113 | None | code309 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No MCB 1 No DOL of S/D Starter suitable for respective HP 1 No Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current and dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S D Star Delta Starter. for outdoor | Mtr | 13125.0 | 13125.0 | 6.0 | False | None | None | False | None | False | 78750.0 | 0 |
| 2939657 | 97113 | None | code310 | Supply and delivery at site 50mm(2) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets | Set | 1732.5 | 1732.5 | 1.0 | False | None | None | False | None | False | 1732.5 | 0 |
| 2939658 | 97113 | None | code311 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs and Nuts,Screw Clips andwater proof Insulation Tape etc complete with ISI mark | Set | 4725.0 | 4725.0 | 1.0 | False | None | None | False | None | False | 4725.0 | 0 |
| 2939659 | 97113 | None | code312 | Supply and delivery at site Stringing of heavy duty Naylone/PP rope with ISI etc complete suitable for Single phase Pumpsets. | Mtr | 42.0 | 42.0 | 90.0 | False | None | None | False | None | False | 3780.0 | 0 |
| 2939660 | 97113 | None | code313 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm dia | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 2939661 | 97113 | None | code314 | Supply and delivery at site of brand new best make non return valve as per IS 778/1984 with ISI Mark and as per its latest amendments.Size 50 mm | No | 1338.75 | 1338.75 | 1.0 | False | None | None | False | None | False | 1338.75 | 0 |
| 2939662 | 97113 | None | code315 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1 x 3 x 2.50 sqmm | Mtr | 102.9 | 102.9 | 100.0 | False | None | None | False | None | False | 10290.0 | 0 |
| 2939663 | 97113 | None | code316 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Set | 6457.5 | 6457.5 | 1.0 | False | None | None | False | None | False | 6457.5 | 0 |
| 2939664 | 97113 | None | code317 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | No | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 |
| 2939665 | 97113 | None | code318 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228 1978 and its latest amendments and with ISI Mark of 6 10 16 20 25 40 Amps with scalable box. | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 2939666 | 97113 | None | code319 | Labour charges for providing connection using insulated sheathed steel wire cable as per IS 1554 1988 with latest amendments from KPTCL pole to meter board unit with all necessary materialstools and equipments as per specifications with testing of as per instructions of engineer incharge of work | Mtr | 157.5 | 157.5 | 30.0 | False | None | None | False | None | False | 4725.0 | 0 |
| 2939667 | 97113 | None | code320 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit | Mtr | 141.75 | 141.75 | 20.0 | False | None | None | False | None | False | 2835.0 | 0 |
| 2939668 | 97113 | None | code321 | Providing main connection from pole PVC insulated sheathed steel wire cable in GI pipe as per IS 1554 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit | Mtr | 84.0 | 84.0 | 6.0 | False | None | None | False | None | False | 504.0 | 0 |
| 2939669 | 97113 | None | code322 | Supplying and fixing LT cast iron potheads suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound
complete with terminals, clamps, bolts, nuts and washers etc. for 3.5 x 6 sqmm | No | 1076.25 | 1076.25 | 1.0 | False | None | None | False | None | False | 1076.25 | 0 |
| 2939670 | 97113 | None | code323 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | No | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 |
| 2939671 | 97113 | None | code324 | Providing Pumping Machinery to Sump (Separate Estimate Enclosed) Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034 2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. (1.5HP/1.1kV,7 STG.) | No | 15067.5 | 15067.5 | 1.0 | False | None | None | False | None | False | 15067.5 | 0 |
| 2939672 | 97113 | None | code325 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover) | Each | 3202.5 | 3202.5 | 1.0 | False | None | None | False | None | False | 3202.5 | 0 |
| 2939673 | 97113 | None | code326 | Supply and delivery at site 50mm(2) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | Mtr | 603.75 | 603.75 | 30.0 | False | None | None | False | None | False | 18112.5 | 0 |
| 2939674 | 97113 | None | code327 | Supply and delivery at site 50mm(2) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets | Set | 1732.5 | 1732.5 | 1.0 | False | None | None | False | None | False | 1732.5 | 0 |
| 2939675 | 97113 | None | code328 | Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs and Nuts,Screw Clips andwater proof Insulation Tape etc complete with ISI mark | Set | 4725.0 | 4725.0 | 1.0 | False | None | None | False | None | False | 4725.0 | 0 |
| 2939676 | 97113 | None | code329 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm dia | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 2939677 | 97113 | None | code330 | Supply and delivery at site of brand new best make non return valve as per IS 778/1984 with ISI Mark and as per its latest amendments.Size 50 mm | No | 1338.75 | 1338.75 | 1.0 | False | None | None | False | None | False | 1338.75 | 0 |
| 2939678 | 97113 | None | code331 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694 1990 with ISI Mark and as per its latest amendments. 1 x 3 x 2.50 sqmm | Mtr | 102.9 | 102.9 | 20.0 | False | None | None | False | None | False | 2058.0 | 0 |
| 2939679 | 97113 | None | code332 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Set | 6457.5 | 6457.5 | 1.0 | False | None | None | False | None | False | 6457.5 | 0 |
| 2939680 | 97113 | None | code333 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 2939681 | 97113 | None | code334 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. | No | 1312.5 | 1312.5 | 1.0 | False | None | None | False | None | False | 1312.5 | 0 |
| 2939682 | 97113 | None | code335 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. | No | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 |
| 2939683 | 97113 | None | code336 | all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work (FROM VOL 1) | Cum | 76.65 | 76.65 | 30.63 | False | None | None | False | None | False | 2347.7895 | 0 |
| 2939684 | 97113 | None | code337 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mix 1:4:8( M7.5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5466.3 | 5466.3 | 1.54 | False | None | None | False | None | False | 8418.102 | 0 |
| 2939685 | 97113 | None | code338 | Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) (P.No 15 , I.No 2.3.1) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6281.1 | 6281.1 | 6.41 | False | None | None | False | None | False | 40261.851 | 0 |
| 2939686 | 97113 | None | code339 | Providing Thermo Mechanically Treated bars of grade Fe 500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) ( pg no 84, I.No 11.32) | Kgs | 96.6 | 96.6 | 641.0 | False | None | None | False | None | False | 61920.6 | 0 |
| 2939687 | 97113 | None | code340 | Providing and removing centreing , shuttering, strutting, propping etc., and removal of form work for lintle, roof beam, slab, stair case, retaining wall for mass concrete including cost of all materials, labour complete as per specifications.Specification (P.No A 7, I.NO 22) RATE 20% on finished rate of concerete | Cum | 3768.66 | 3768.66 | 6.4099 | False | None | None | False | None | False | 24156.733734 | 0 |
| 2939688 | 97113 | None | code341 | Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4 6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 477.75 | 477.75 | 31.05 | False | None | None | False | None | False | 14834.1375 | 0 |
| 2939689 | 97113 | None | code342 | Providing and fixing 60 x 60 cms. MS insepection door with necessary MS frame made out of M.S. angle of 50 x 50 x 6 mm and M.S. Shutter of 31.5 mm or B.G. 10 thick with hinges on top and locking arrangement, painting etc., complete | No | 1908.9 | 1908.9 | 1.0 | False | None | None | False | None | False | 1908.9 | 0 |
| 2939690 | 97113 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m, GOK CSOR-2022 VOLUME I. No. 1.14.1 P.No.8 | Cum | 80.48 | 80.48 | 290.8548 | False | None | None | False | None | False | 23407.994304 | 0 |
| 2939691 | 97113 | None | code02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m., GOK CSOR-2022 VOLUME I. No. 1.9 P.No.7 | Cum | 214.2 | 214.2 | 579.3 | False | None | None | False | None | False | 124086.06 | 0 |
| 2939692 | 97113 | None | code03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications., GOK CSOR-2022 VOLUME II. No. 4.1 P.No.5 | Sqm | 99.75 | 99.75 | 220.5116 | False | None | None | False | None | False | 21996.0321 | 0 |
| 2939693 | 97113 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand), GOK CSOR-2022 VOLUME II. No. 5.1.1 P.No.9 | Cum | 4987.5 | 4987.5 | 84.453 | False | None | None | False | None | False | 421209.3375 | 0 |
| 2939694 | 97113 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand), GOK CSOR-2022 VOLUME II. No. 5.3 P.No.9 | Cum | 5457.9 | 5457.9 | 56.095 | False | None | None | False | None | False | 306160.9005 | 0 |
| 2939695 | 97113 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.1.2 P.No.15 | Cum | 5466.3 | 5466.3 | 103.306 | False | None | None | False | None | False | 564701.5878 | 0 |
| 2939696 | 97113 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.2.1.1 P.No.15 | Cum | 6240.15 | 6240.15 | 53.545 | False | None | None | False | None | False | 334128.83175 | 0 |
| 2939697 | 97113 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.5.1 P.No.17 | Cum | 6491.1 | 6491.1 | 100.172 | False | None | None | False | None | False | 650226.4692 | 0 |
| 2939698 | 97113 | None | code09 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.3.1 P.No.16 | Cum | 6266.4 | 6266.4 | 45.6902 | False | None | None | False | None | False | 286313.06928 | 0 |
| 2939699 | 97113 | None | code10 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work., GOK CSOR-2022 VOLUME II. No.6.8 P.No.14 | Cum | 7024.5 | 7024.5 | 120.6866 | False | None | None | False | None | False | 847763.0217 | 0 |
| 2939700 | 97113 | None | code11 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work, GOK CSOR-2022 VOLUME II. No.6.15 P.No.14 | Sqm | 909.3 | 909.3 | 7.84 | False | None | None | False | None | False | 7128.912 | 0 |
| 2939701 | 97113 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut-ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately), GOK CSOR-2022 VOLUME II. No.11.32 P.No.84 | Kg | 100.8 | 100.8 | 12297.3821 | False | None | None | False | None | False | 1239576.11568 | 0 |
| 2939702 | 97113 | None | code13 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for Shuttering of Footing | Sqm | 499.21 | 499.21 | 34.992 | False | None | None | False | None | False | 17468.35632 | 0 |
| 2939703 | 97113 | None | code14 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for RCC Beams, Lintels, | Sqm | 3894.66 | 3894.66 | 21.1202 | False | None | None | False | None | False | 82255.998132 | 0 |
| 2939704 | 97113 | None | code15 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : , Rate for RCC Plinth Beams, Roof (Straight) | Sqm | 499.21 | 499.21 | 66.372 | False | None | None | False | None | False | 33133.56612 | 0 |
| 2939705 | 97113 | None | code16 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for RCC Columns and Piers | Sqm | 499.21 | 499.21 | 30.351 | False | None | None | False | None | False | 15151.52271 | 0 |
| 2939706 | 97113 | None | code17 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : : Rate for RCC Chejja, Canopy, & other Architectural Projections. | Sqm | 499.21 | 499.21 | 0.882 | False | None | None | False | None | False | 440.30322 | 0 |
| 2939707 | 97113 | None | code18 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work., GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.1.1 P.No.41 | Sqm | 223.65 | 223.65 | 191.4083 | False | None | None | False | None | False | 42808.466295 | 0 |
| 2939708 | 97113 | None | code19 | Providing 15 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work., GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.2.1 P.No.41 | Sqm | 260.4 | 260.4 | 341.8204 | False | None | None | False | None | False | 89010.03216 | 0 |
| 2939709 | 97113 | None | code20 | Providing 18 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge., GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.3.1 P.No.41 | Sqm | 313.95 | 313.95 | 406.0194 | False | None | None | False | None | False | 127469.79063 | 0 |
| 2939710 | 97113 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge., GOK CSOR-2022 VOLUME II. No.8.51 P.No.50 | Sqm | 87.15 | 87.15 | 533.2288 | False | None | None | False | None | False | 46470.88992 | 0 |
| 2939711 | 97113 | None | code22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge., GOVERNAMENT OF KARNTAKA PWD CSOR -2022, I.NO:8.27 P.NO: 45 | Sqm | 42.0 | 42.0 | 533.2288 | False | None | None | False | None | False | 22395.6096 | 0 |
| 2939712 | 97113 | None | code23 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for inside walls Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.8.39 P.No.48 | Sqm | 99.75 | 99.75 | 533.2288 | False | None | None | False | None | False | 53189.5728 | 0 |
| 2939713 | 97113 | None | code24 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.8.30 P.No.46 | Sqm | 142.8 | 142.8 | 406.0194 | False | None | None | False | None | False | 57979.57032 | 0 |
| 2939714 | 97113 | None | code25 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.8.33.2 P.No.46 | Sqm | 110.25 | 110.25 | 18.72 | False | None | None | False | None | False | 2063.88 | 0 |
| 2939715 | 97113 | None | code26 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.8.33.3 P.No.47 | Sqm | 111.3 | 111.3 | 53.3 | False | None | None | False | None | False | 5932.29 | 0 |
| 2939716 | 97113 | None | code27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.9.24 P.No.63 | Sqm | 3013.5 | 3013.5 | 63.384 | False | None | None | False | None | False | 191007.684 | 0 |
| 2939717 | 97113 | None | code28 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge, GOK CSOR-2022 VOLUME II. No.10.2 P.No.69 | m | 282.45 | 282.45 | 95.06 | False | None | None | False | None | False | 26849.697 | 0 |
| 2939718 | 97113 | None | code29 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.9.17.2 P.No.61 | Sqm | 1157.1 | 1157.1 | 249.4434 | False | None | None | False | None | False | 288630.95814 | 0 |
| 2939719 | 97113 | None | code30 | Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications., GOK CSOR-2022 VOLUME II. No.9.31 P.No.64 | Sqm | 1141.35 | 1141.35 | 238.9236 | False | None | None | False | None | False | 272695.45086 | 0 |
| 2939720 | 97113 | None | code31 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete., GOK CSOR-2022 VOLUME II. No.10.74 P.No.71 | Sqm | 1022.7 | 1022.7 | 16.38 | False | None | None | False | None | False | 16751.826 | 0 |
| 2939721 | 97113 | None | code32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete., GOK CSOR-2022 VOLUME II. No.9.9 P.No.60 | Sqm | 635.25 | 635.25 | 3.5999 | False | None | None | False | None | False | 2286.836475 | 0 |
| 2939722 | 97113 | None | code33 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications, GOK CSOR-2022 VOLUME II. No.12.13.1 P.No.98 | Sqm | 64683.15 | 64683.15 | 0.1657 | False | None | None | False | None | False | 10717.997955 | 0 |
| 2939723 | 97113 | None | code34 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications., GOK CSOR-2022 VOLUME II. No.12.51 P.No.103 | Nos | 1559.25 | 1559.25 | 4.0 | False | None | None | False | None | False | 6237.0 | 0 |
| 2939724 | 97113 | None | code35 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ), GOK CSOR-2022 VOLUME II. No.12.15 P.No.98 | Sqm | 4783.8 | 4783.8 | 7.14 | False | None | None | False | None | False | 34156.332 | 0 |
| 2939725 | 97113 | None | code36 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.12.54 P.No.103 | Sqm | 498.75 | 498.75 | 2.1 | False | None | None | False | None | False | 1047.375 | 0 |
| 2939726 | 97113 | None | code37 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete., GOK CSOR-2022 VOLUME II. No.12.58 P.No.105 | Nos | 114.45 | 114.45 | 4.0 | False | None | None | False | None | False | 457.8 | 0 |
| 2939727 | 97113 | None | code38 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete, GOK CSOR-2022 VOLUME II. No.12.63 P.No.105 | Sqm | 115.5 | 115.5 | 8.0 | False | None | None | False | None | False | 924.0 | 0 |
| 2939728 | 97113 | None | code39 | Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm dia, GOK CSOR-2022 VOLUME II. No.12.66 P.No.105 | m | 373.8 | 373.8 | 11.2 | False | None | None | False | None | False | 4186.56 | 0 |
| 2939729 | 97113 | None | code40 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :, GOK CSOR-2022 VOLUME II. No.12.72 P.No.105 | Each | 37.8 | 37.8 | 1.0 | False | None | None | False | None | False | 37.8 | 0 |
| 2939730 | 97113 | None | code41 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm, GOK CSOR-2022 VOLUME II. No.12.76.2 P.No.107 | Each | 286.65 | 286.65 | 6.0 | False | None | None | False | None | False | 1719.9 | 0 |
| 2939731 | 97113 | None | code42 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100x58x1.90mm, GOK CSOR-2022 VOLUME II. No.12.74.2 P.No.106 | Nos | 76.65 | 76.65 | 12.0 | False | None | None | False | None | False | 919.8 | 0 |
| 2939732 | 97113 | None | code43 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge., GOK CSOR-2022 VOLUME II. No.11.6.1 P.No.76 | Sqm | 2635.5 | 2635.5 | 10.24 | False | None | None | False | None | False | 26987.52 | 0 |
| 2939733 | 97113 | None | code44 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made), GOK CSOR-2022 VOLUME II. No.12.89 P.No.109 | Sqm | 7058.1 | 7058.1 | 15.75 | False | None | None | False | None | False | 111165.075 | 0 |
| 2939734 | 97113 | None | code45 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made), GOK CSOR-2022 VOLUME II. No.12.85 P.No.108 | Sqm | 5113.5 | 5113.5 | 0.345 | False | None | None | False | None | False | 1764.1575 | 0 |
| 2939735 | 97113 | None | code46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc., GOK CSOR-2022 VOLUME II. No.11.34B P.No.85 | Kg | 150.15 | 150.15 | 346.5 | False | None | None | False | None | False | 52026.975 | 0 |
| 2939736 | 97113 | None | code47 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge., GOK CSOR-2022 VOLUME II. No.11.26.1 P.No.82 | Kg | 115.5 | 115.5 | 330.0 | False | None | None | False | None | False | 38115.0 | 0 |
| 2939737 | 97113 | None | code48 | Providing & Fixing of Mineral Fibre Suspended Ceiling System in the module size of 600x600x19mm with Exposed grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 87%, Thermal Conductivity k = 0.052 - 0.057 w/m K, NRC -0.7,Colour White, Fire Performance UK A2 S1, dO, with Anti Microbial coating on the face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with cleanroom class of ISO 5 (Class 100), Decontamination Class of CP1Oand Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D-4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2& pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with suspension system of approved make, GOK CSOR-2022 VOLUME II. No.7.50 P.No.32 | Sqm | 1948.8 | 1948.8 | 69.7284 | False | None | None | False | None | False | 135886.70592 | 0 |
| 2939738 | 97113 | None | code49 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.19.3 P.No.163 | Cum | 1950.9 | 1950.9 | 29.6143 | False | None | None | False | None | False | 57774.53787 | 0 |
| 2939739 | 97113 | None | code50 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. In Cement Mortar, GOK CSOR-2022 VOLUME II. No.19.7.3 P.No.163 | Cum | 828.45 | 828.45 | 280.32 | False | None | None | False | None | False | 232231.104 | 0 |
| 2939740 | 97113 | None | code51 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin-charge. In Cement Mortar, GOK CSOR-2022 VOLUME II. No.19.9.2 P.No.163 | Cum | 1354.5 | 1354.5 | 15.768 | False | None | None | False | None | False | 21357.756 | 0 |
| 2939741 | 97113 | None | code52 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge., GOK CSOR-2022 VOLUME II. No.19.12 P.No.164 | Sqm | 193.2 | 193.2 | 19.5 | False | None | None | False | None | False | 3767.4 | 0 |
| 2939742 | 97113 | None | code53 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.5.1 P.No.A(69) | Cum | 6552.92 | 6552.92 | 28.3535 | False | None | None | False | None | False | 185798.21722 | 0 |
| 2939743 | 97113 | None | code54 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work., GOK CSOR-2022 VOLUME II. No.6.8 P.No.14 | Cum | 7024.5 | 7024.5 | 48.2363 | False | None | None | False | None | False | 338835.88935 | 0 |
| 2939744 | 97113 | None | code55 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work, GOK CSOR-2022 VOLUME II. No.6.15 P.No.14 | Sqm | 909.3 | 909.3 | 9.7537 | False | None | None | False | None | False | 8869.03941 | 0 |
| 2939745 | 97113 | None | code56 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut-ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately), GOK CSOR-2022 VOLUME II. No.11.32 P.No.84 | Kg | 100.8 | 100.8 | 2835.3557 | False | None | None | False | None | False | 285803.85456 | 0 |
| 2939746 | 97113 | None | code57 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for Shuttering of Footing | Sqm | 3894.66 | 3894.66 | 6.141 | False | None | None | False | None | False | 23917.10706 | 0 |
| 2939747 | 97113 | None | code58 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for Shuttering of Footing | Sqm | 106.0 | 106.0 | 18.6917 | False | None | None | False | None | False | 1981.3202 | 0 |
| 2939748 | 97113 | None | code59 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for Shuttering of Footing | Sqm | 4.75 | 4.75 | 2.9808 | False | None | None | False | None | False | 14.1588 | 0 |
| 2939749 | 97113 | None | code60 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17), GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 : Rate for Shuttering of Footing | Sqm | 4.75 | 4.75 | 0.5399 | False | None | None | False | None | False | 2.564525 | 0 |
| 2939750 | 97113 | None | code61 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work., GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.1.1 P.No.41 | Sqm | 223.65 | 223.65 | 96.0924 | False | None | None | False | None | False | 21491.06526 | 0 |
| 2939751 | 97113 | None | code62 | Providing 15 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work., GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.2.1 P.No.41 | Sqm | 260.4 | 260.4 | 235.9091 | False | None | None | False | None | False | 61430.72964 | 0 |
| 2939752 | 97113 | None | code63 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge., GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.3.1 P.No.41 | Sqm | 313.95 | 313.95 | 289.5692 | False | None | None | False | None | False | 90910.25034 | 0 |
| 2939753 | 97113 | None | code64 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge., GOK CSOR-2022 VOLUME II. No.8.51 P.No.50 | Sqm | 87.15 | 87.15 | 332.0016 | False | None | None | False | None | False | 28933.93944 | 0 |
| 2939754 | 97113 | None | code65 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge., GOVERNAMENT OF KARNTAKA PWD CSOR -2022, I.NO:8.27 P.NO: 45 | Sqm | 42.0 | 42.0 | 332.0016 | False | None | None | False | None | False | 13944.0672 | 0 |
| 2939755 | 97113 | None | code66 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for inside walls Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.8.39 P.No.48 | Sqm | 99.75 | 99.75 | 332.0016 | False | None | None | False | None | False | 33117.1596 | 0 |
| 2939756 | 97113 | None | code67 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.8.30 P.No.46 | Sqm | 142.8 | 142.8 | 289.5692 | False | None | None | False | None | False | 41350.48176 | 0 |
| 2939757 | 97113 | None | code68 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.8.33.2 P.No.46 | Sqm | 110.25 | 110.25 | 12.6 | False | None | None | False | None | False | 1389.15 | 0 |
| 2939758 | 97113 | None | code69 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.8.33.3 P.No.47 | Sqm | 111.3 | 111.3 | 27.0 | False | None | None | False | None | False | 3005.1 | 0 |
| 2939759 | 97113 | None | code70 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.9.24 P.No.63 | Sqm | 3013.5 | 3013.5 | 20.625 | False | None | None | False | None | False | 62153.4375 | 0 |
| 2939760 | 97113 | None | code71 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge, GOK CSOR-2022 VOLUME II. No.10.2 P.No.69 | m | 282.45 | 282.45 | 28.0 | False | None | None | False | None | False | 7908.6 | 0 |
| 2939761 | 97113 | None | code72 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Ground Floor ---- As per directions of engineer in charge of work., GOK CSOR-2022 VOLUME II. No.9.17.2 P.No.61 | Sqm | 1157.1 | 1157.1 | 116.0767 | False | None | None | False | None | False | 134312.34957 | 0 |
| 2939762 | 97113 | None | code73 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete., GOK CSOR-2022 VOLUME II. No.10.74 P.No.71 | Sqm | 1022.7 | 1022.7 | 20.0417 | False | None | None | False | None | False | 20496.64659 | 0 |
| 2939763 | 97113 | None | code74 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete., GOK CSOR-2022 VOLUME II. No.9.9 P.No.60 | Sqm | 635.25 | 635.25 | 5.346 | False | None | None | False | None | False | 3396.0465 | 0 |
| 2939764 | 97113 | None | code75 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications, GOK CSOR-2022 VOLUME II. No.12.13.1 P.No.98 | Sqm | 64683.15 | 64683.15 | 0.189 | False | None | None | False | None | False | 12225.11535 | 0 |
| 2939765 | 97113 | None | code76 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications., GOK CSOR-2022 VOLUME II. No.12.51 P.No.103 | Nos | 1559.25 | 1559.25 | 5.0 | False | None | None | False | None | False | 7796.25 | 0 |
| 2939766 | 97113 | None | code77 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ), GOK CSOR-2022 VOLUME II. No.12.15 P.No.98 | Sqm | 4783.8 | 4783.8 | 8.52 | False | None | None | False | None | False | 40757.976 | 0 |
| 2939767 | 97113 | None | code78 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge., GOK CSOR-2022 VOLUME II. No.12.54 P.No.103 | Sqm | 498.75 | 498.75 | 2.1 | False | None | None | False | None | False | 1047.375 | 0 |
| 2939768 | 97113 | None | code79 | Total Qty, Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. | Nos | 114.45 | 114.45 | 4.0 | False | None | None | False | None | False | 457.8 | 0 |
| 2939769 | 97113 | None | code80 | Total Qty, Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete | Sqm | 115.5 | 115.5 | 8.0 | False | None | None | False | None | False | 924.0 | 0 |
| 2939770 | 97113 | None | code81 | Total Qty, Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm dia | m | 373.8 | 373.8 | 10.8 | False | None | None | False | None | False | 4037.04 | 0 |
| 2939771 | 97113 | None | code82 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete :, GOK CSOR-2022 VOLUME II. No.12.72 P.No.105 | Each | 37.8 | 37.8 | 1.0 | False | None | None | False | None | False | 37.8 | 0 |
| 2939772 | 97113 | None | code83 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm, GOK CSOR-2022 VOLUME II. No.12.76.2 P.No.107 | Each | 286.65 | 286.65 | 4.0 | False | None | None | False | None | False | 1146.6 | 0 |
| 2939773 | 97113 | None | code84 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100x58x1.90mm, GOK CSOR-2022 VOLUME II. No.12.74.2 P.No.106 | Nos | 76.65 | 76.65 | 15.0 | False | None | None | False | None | False | 1149.75 | 0 |
| 2939774 | 97113 | None | code85 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made), GOK CSOR-2022 VOLUME II. No.12.89 P.No.109 | Sqm | 7058.1 | 7058.1 | 13.5 | False | None | None | False | None | False | 95284.35 | 0 |
| 2939775 | 97113 | None | code86 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made), GOK CSOR-2022 VOLUME II. No.12.85 P.No.108 | Sqm | 5113.5 | 5113.5 | 0.276 | False | None | None | False | None | False | 1411.326 | 0 |
| 2939776 | 97113 | None | code87 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc., GOK CSOR-2022 VOLUME II. No.11.34B P.No.85 | Kg | 150.15 | 150.15 | 283.5 | False | None | None | False | None | False | 42567.525 | 0 |
| 2939777 | 97113 | None | code88 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge., GOK CSOR-2022 VOLUME II. No.11.26.1 P.No.82 | Kg | 115.5 | 115.5 | 346.5 | False | None | None | False | None | False | 40020.75 | 0 |
| 2939778 | 97113 | None | code89 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge., GOK CSOR-2022 VOLUME II. No.15.1 P.No.131 | Sqm | 782.25 | 782.25 | 210.4766 | False | None | None | False | None | False | 164645.32035 | 0 |
| 2939779 | 97113 | None | code90 | Providing & Fixing of Mineral Fibre Suspended Ceiling System in the module size of 600x600x19mm with Exposed grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 87%, Thermal Conductivity k = 0.052 - 0.057 w/m K, NRC -0.7,Colour White, Fire Performance UK A2 S1, dO, with Anti Microbial coating on the face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with cleanroom class of ISO 5 (Class 100), Decontamination Class of CP1Oand Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D-4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2& pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with suspension system of approved make, GOK CSOR-2022 VOLUME II. No.7.50 P.No.32 | Sqm | 1948.8 | 1948.8 | 36.0008 | False | None | None | False | None | False | 70158.35904 | 0 |
| 2939780 | 97113 | None | code91 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made
out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per
ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse
sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories,
sealing shall be done with necessary rods etc., complete For Straight Portion, GOK CSOR-2022 VOLUME II. No.10.15.1 P.No.71 | Sqm | 4135.95 | 4135.95 | 36.0008 | False | None | None | False | None | False | 148897.50876 | 0 |
| 2939781 | 97113 | None | code92 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion, GOK CSOR-2022 VOLUME II. No.10.15.1 P.No.71 | Sqm | 4135.95 | 4135.95 | 111.21 | False | None | None | False | None | False | 459958.9995 | 0 |
| 2939782 | 97113 | None | code93 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6 12 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2,+ 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement, GOK CSOR 2022 VOLUME II. No.18.3 P.No.159 | Sqm | 2836.05 | 2836.05 | 33.363 | False | None | None | False | None | False | 94619.13615 | 0 |
| 2939783 | 97113 | None | code94 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 412.65 | 412.65 | 150.0 | False | None | None | False | None | False | 61897.5 | 0 |
| 2939784 | 97113 | None | code95 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Conceled work, including cutting chases and making good the walls etc. 20mm dia Pipes., GOK CSOR-2022 VOLUME II. No.13.32.2 Addendum | Mtr | 391.65 | 391.65 | 40.0 | False | None | None | False | None | False | 15666.0 | 0 |
| 2939785 | 97113 | None | code96 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 for rain water, GOK CSOR-2022 VOLUME V. I.No.M010G Page 134 | l | 413.7 | 413.7 | 65.2 | False | None | None | False | None | False | 26973.24 | 0 |
| 2939786 | 97113 | None | code97 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, Confirming to ISI:12701, Colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & Over flow pipes. the base support i/c fittings and fixtures for tank shall be paid separately., GOK CSOR-2022 VOLUME II. No.13.34A Addendum | l | 8.92 | 8.92 | 2000.0 | False | None | None | False | None | False | 17840.0 | 0 |
| 2939787 | 97113 | None | code98 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bor, GOK CSOR-2022 VOLUME II. No.13.4.3 P.No.115 | Nos | 715.05 | 715.05 | 4.0 | False | None | None | False | None | False | 2860.2 | 0 |
| 2939788 | 97113 | None | code99 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g., GOK CSOR-2022 VOLUME II. No.13.13 P.No.117 | Nos | 707.7 | 707.7 | 7.0 | False | None | None | False | None | False | 4953.9 | 0 |
| 2939789 | 97113 | None | code100 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, GOK CSOR-2022 VOLUME II. No.13.15 P.No.117 | Nos | 605.85 | 605.85 | 5.0 | False | None | None | False | None | False | 3029.25 | 0 |
| 2939790 | 97113 | None | code101 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid, GOK CSOR-2022 VOLUME II. No.14.3.1 P.No.123 | Each | 5255.25 | 5255.25 | 2.0 | False | None | None | False | None | False | 10510.5 | 0 |
| 2939791 | 97113 | None | code102 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern, GOK CSOR-2022 VOLUME II. No.14.5.1 P.No.122 | Each | 6959.4 | 6959.4 | 2.0 | False | None | None | False | None | False | 13918.8 | 0 |
| 2939792 | 97113 | None | code103 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps, GOK CSOR-2022 VOLUME II. No.14.7.1 P.No.122 | Each | 2655.45 | 2655.45 | 2.0 | False | None | None | False | None | False | 5310.9 | 0 |
| 2939793 | 97113 | None | code104 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm, GOK CSOR-2022 VOLUME II. No.14.32.2 P.No.126 | Each | 912.45 | 912.45 | 2.0 | False | None | None | False | None | False | 1824.9 | 0 |
| 2939794 | 97113 | None | code105 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe, GOK CSOR-2022 VOLUME II. No.14.28.2.2 P.No.128 | Each | 228.9 | 228.9 | 6.0 | False | None | None | False | None | False | 1373.4 | 0 |
| 2939795 | 97113 | None | code106 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms, GOK CSOR-2022 VOLUME II. No.14.38 P.No.129 | Each | 121.8 | 121.8 | 2.0 | False | None | None | False | None | False | 243.6 | 0 |
| 2939796 | 97113 | None | code107 | Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.., GOK CSOR-2022 VOLUME II. No.T130D P.No.187 | Each | 3402.0 | 3402.0 | 10.0 | False | None | None | False | None | False | 34020.0 | 0 |
| 2939797 | 97113 | None | code108 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges andsuch simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m, GOK CSOR-2022 VOLUME II. No.1.4.1 P.No.5 | Cum | 195.3 | 195.3 | 39.5999 | False | None | None | False | None | False | 7733.86047 | 0 |
| 2939798 | 97113 | None | code109 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications, GOK CSOR-2022 VOLUME II. No.1.10 P.No.5 | Cum | 128.1 | 128.1 | 15.2999 | False | None | None | False | None | False | 1959.91719 | 0 |
| 2939799 | 97113 | None | code110 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.1.2 P.No.A(67) | Cum | 5632.2 | 5632.2 | 5.85 | False | None | None | False | None | False | 32948.37 | 0 |
| 2939800 | 97113 | None | code111 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 70.0 | 70.0 | 204.1 | False | None | None | False | None | False | 14287.0 | 0 |
| 2939801 | 97113 | None | code112 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 251.0 | 251.0 | 12.0 | False | None | None | False | None | False | 3012.0 | 0 |
| 2939802 | 97113 | None | code113 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 361.0 | 361.0 | 17.0 | False | None | None | False | None | False | 6137.0 | 0 |
| 2939803 | 97113 | None | code114 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 542.0 | 542.0 | 10.0 | False | None | None | False | None | False | 5420.0 | 0 |
| 2939804 | 97113 | None | code115 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 26.0 | 26.0 | 2000.0 | False | None | None | False | None | False | 52000.0 | 0 |
| 2939805 | 97113 | None | code116 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 40.0 | 40.0 | 1000.0 | False | None | None | False | None | False | 40000.0 | 0 |
| 2939806 | 97113 | None | code117 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 59.0 | 59.0 | 600.0 | False | None | None | False | None | False | 35400.0 | 0 |
| 2939807 | 97113 | None | code118 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 138.0 | 138.0 | 8.0 | False | None | None | False | None | False | 1104.0 | 0 |
| 2939808 | 97113 | None | code119 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 250.0 | 250.0 | 24.0 | False | None | None | False | None | False | 6000.0 | 0 |
| 2939809 | 97113 | None | code120 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 325.0 | 325.0 | 15.0 | False | None | None | False | None | False | 4875.0 | 0 |
| 2939810 | 97113 | None | code121 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 175.0 | 175.0 | 10.0 | False | None | None | False | None | False | 1750.0 | 0 |
| 2939811 | 97113 | None | code122 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 302.0 | 302.0 | 15.0 | False | None | None | False | None | False | 4530.0 | 0 |
| 2939812 | 97113 | None | code123 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 363.0 | 363.0 | 15.0 | False | None | None | False | None | False | 5445.0 | 0 |
| 2939813 | 97113 | None | code124 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 88.0 | 88.0 | 150.0 | False | None | None | False | None | False | 13200.0 | 0 |
| 2939814 | 97113 | None | code125 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 152.0 | 152.0 | 6.0 | False | None | None | False | None | False | 912.0 | 0 |
| 2939815 | 97113 | None | code126 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 162.0 | 162.0 | 30.0 | False | None | None | False | None | False | 4860.0 | 0 |
| 2939816 | 97113 | None | code127 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 313.0 | 313.0 | 12.0 | False | None | None | False | None | False | 3756.0 | 0 |
| 2939817 | 97113 | None | code128 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 375.0 | 375.0 | 25.0 | False | None | None | False | None | False | 9375.0 | 0 |
| 2939818 | 97113 | None | code129 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 249.0 | 249.0 | 30.0 | False | None | None | False | None | False | 7470.0 | 0 |
| 2939819 | 97113 | None | code130 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 211.0 | 211.0 | 20.0 | False | None | None | False | None | False | 4220.0 | 0 |
| 2939820 | 97113 | None | code131 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | No | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
| 2939821 | 97113 | None | code132 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | No | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 |
| 2939822 | 97113 | None | code133 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 3053.0 | 3053.0 | 6.0 | False | None | None | False | None | False | 18318.0 | 0 |
| 2939823 | 97113 | None | code134 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 523.0 | 523.0 | 20.0 | False | None | None | False | None | False | 10460.0 | 0 |
| 2939824 | 97113 | None | code135 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 2826.0 | 2826.0 | 10.0 | False | None | None | False | None | False | 28260.0 | 0 |
| 2939825 | 97113 | None | code136 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 2085.0 | 2085.0 | 10.0 | False | None | None | False | None | False | 20850.0 | 0 |
| 2939826 | 97113 | None | code137 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 44570.0 | 44570.0 | 6.0 | False | None | None | False | None | False | 267420.0 | 0 |
| 2939827 | 97113 | None | code138 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 34.0 | 34.0 | 600.0 | False | None | None | False | None | False | 20400.0 | 0 |
| 2939828 | 97113 | None | code139 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 20411.0 | 20411.0 | 2.0 | False | None | None | False | None | False | 40822.0 | 0 |
| 2939829 | 97113 | None | code140 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 5343.0 | 5343.0 | 3.0 | False | None | None | False | None | False | 16029.0 | 0 |
| 2939830 | 97113 | None | code141 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 286.0 | 286.0 | 20.0 | False | None | None | False | None | False | 5720.0 | 0 |
| 2939831 | 97113 | None | code142 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 38661.0 | 38661.0 | 1.0 | False | None | None | False | None | False | 38661.0 | 0 |
| 2939832 | 97113 | None | code143 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 10748.0 | 10748.0 | 20.0 | False | None | None | False | None | False | 214960.0 | 0 |
| 2939833 | 97113 | None | code144 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Nos | 5651.0 | 5651.0 | 40.0 | False | None | None | False | None | False | 226040.0 | 0 |
| 2939834 | 97113 | None | code145 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Each | 1478.0 | 1478.0 | 20.0 | False | None | None | False | None | False | 29560.0 | 0 |
| 2939835 | 97113 | None | code146 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 163.0 | 163.0 | 12.0 | False | None | None | False | None | False | 1956.0 | 0 |
| 2939836 | 97113 | None | code147 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Nos | 9500.0 | 9500.0 | 6.0 | False | None | None | False | None | False | 57000.0 | 0 |
| 2939837 | 97113 | None | code148 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Nos | 9500.0 | 9500.0 | 2.0 | False | None | None | False | None | False | 19000.0 | 0 |
| 2939838 | 97113 | None | code149 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Nos | 4500.0 | 4500.0 | 1.0 | False | None | None | False | None | False | 4500.0 | 0 |
| 2939839 | 97113 | None | code150 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Nos | 3500.0 | 3500.0 | 1.0 | False | None | None | False | None | False | 3500.0 | 0 |
| 2939840 | 97113 | None | code151 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 34.0 | 34.0 | 300.0 | False | None | None | False | None | False | 10200.0 | 0 |
| 2939841 | 97113 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m GOK CSOR-2022 VOLUME I. No. 1.14.1 P.No.8 | Cum | 76.65 | 76.65 | 123.6853 | False | None | None | False | None | False | 9480.478245 | 0 |
| 2939842 | 97113 | None | code02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. GOK CSOR-2022 VOLUME I. No. 1.9 P.No.7 | Cum | 214.2 | 214.2 | 180.9259 | False | None | None | False | None | False | 38754.32778 | 0 |
| 2939843 | 97113 | None | code03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 ltr/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. GOK CSOR-2022 VOLUME II. No. 4.1 P.No.5 | Sqm | 99.75 | 99.75 | 100.3401 | False | None | None | False | None | False | 10008.924975 | 0 |
| 2939844 | 97113 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) GOK CSOR-2022 VOLUME II. No. 5.1.1 P.No.9 | Cum | 4987.5 | 4987.5 | 26.2192 | False | None | None | False | None | False | 130768.26 | 0 |
| 2939845 | 97113 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) GOK CSOR-2022 VOLUME II. No. 5.3 P.No.9 | Cum | 5457.9 | 5457.9 | 19.1208 | False | None | None | False | None | False | 104359.41432 | 0 |
| 2939846 | 97113 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates GOK CSOR-2022 VOLUME I. No.2.1.2 P.No.15 | Cum | 5466.3 | 5466.3 | 32.4648 | False | None | None | False | None | False | 177462.33624 | 0 |
| 2939847 | 97113 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6240.15 | 6240.15 | 30.9521 | False | None | None | False | None | False | 193145.746815 | 0 |
| 2939848 | 97113 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates | Cum | 6491.1 | 6491.1 | 55.9451 | False | None | None | False | None | False | 363145.23861 | 0 |
| 2939849 | 97113 | None | code09 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers not exceeding 150 mm thickness, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates GOK CSOR-2022 VOLUME I. No.2.3.1 P.No.16 GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.1.1 P.No.41 | Cum | 6266.4 | 6266.4 | 6.7264 | False | None | None | False | None | False | 42150.31296 | 0 |
| 2939850 | 97113 | None | code10 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. GOK CSOR-2022 VOLUME II. No.6.8 P.No.14 | Cum | 7024.5 | 7024.5 | 33.8053 | False | None | None | False | None | False | 237465.32985 | 0 |
| 2939851 | 97113 | None | code11 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work GOK CSOR-2022 VOLUME II. No.6.15 P.No.14 | Sqm | 909.3 | 909.3 | 9.6 | False | None | None | False | None | False | 8729.28 | 0 |
| 2939852 | 97113 | None | code12 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cut-ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) GOK CSOR-2022 VOLUME II. No.11.32 P.No.84 | Kg | 96.6 | 96.6 | 8689.7305 | False | None | None | False | None | False | 839427.9663 | 0 |
| 2939853 | 97113 | None | code13 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17) GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 | Sqm | 499.21 | 499.21 | 21.384 | False | None | None | False | None | False | 10675.10664 | 0 |
| 2939854 | 97113 | None | code14 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17) GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 (Beams,Lintel) | Sqm | 3894.66 | 3894.66 | 11.7395 | False | None | None | False | None | False | 45721.36107 | 0 |
| 2939855 | 97113 | None | code15 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17) GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17(Plinth beam) | Sqm | 3245.55 | 3245.55 | 35.7028 | False | None | None | False | None | False | 115875.22254 | 0 |
| 2939856 | 97113 | None | code16 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17) GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17 (Column,Peirs) | Sqm | 4543.76 | 4543.76 | 17.6659 | False | None | None | False | None | False | 80269.609784 | 0 |
| 2939857 | 97113 | None | code17 | Providing & fixing Shuttering for Footing,Beams,Columns & Slab. (GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17) GOK PWD SOR BUILDINGS -2022 Preface No.22 P.No.(A) 17(Chajja,Canopy) | Sqm | 2920.99 | 2920.99 | 0.405 | False | None | None | False | None | False | 1183.00095 | 0 |
| 2939858 | 97113 | None | code18 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work. | Sqm | 223.65 | 223.65 | 75.0123 | False | None | None | False | None | False | 16776.500895 | 0 |
| 2939859 | 97113 | None | code19 | Providing 15 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. for ceiling Ground Floor ---- As per directions of engineer in charge of work. GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.2.1 P.No.41 | Sqm | 260.4 | 260.4 | 178.0626 | False | None | None | False | None | False | 46367.50104 | 0 |
| 2939860 | 97113 | None | code20 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GOK PWD SOR BUILDINGS -2022 VOLUME II. No.8.3.1 P.No.41 | Sqm | 313.95 | 313.95 | 404.0117 | False | None | None | False | None | False | 126839.473215 | 0 |
| 2939861 | 97113 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. GOK CSOR-2022 VOLUME II. No.8.51 P.No.50 | Sqm | 87.15 | 87.15 | 253.0749 | False | None | None | False | None | False | 22055.477535 | 0 |
| 2939862 | 97113 | None | code22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GOVERNAMENT OF KARNTAKA PWD CSOR -2022, I.NO:8.27 P.NO: 45 | Sqm | 42.0 | 42.0 | 253.0749 | False | None | None | False | None | False | 10629.1458 | 0 |
| 2939863 | 97113 | None | code23 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. for inside walls Ground Floor ---- As per directions of engineer in charge of work. GOK CSOR-2022 VOLUME II. No.8.39 P.No.48 | Sqm | 99.75 | 99.75 | 253.0749 | False | None | None | False | None | False | 25244.221275 | 0 |
| 2939864 | 97113 | None | code24 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m over and including priming coat of exterior primer applied @ 2.20 kg/10 m) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground Floor - As per directions of engineer in charge of work. GOK CSOR-2022 VOLUME II. No.8.30 P.No.46 | Sqm | 142.8 | 142.8 | 404.0117 | False | None | None | False | None | False | 57692.87076 | 0 |
| 2939865 | 97113 | None | code25 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GOK CSOR-2022 VOLUME II. No.8.33.2 P.No.46 | Sqm | 110.25 | 110.25 | 10.08 | False | None | None | False | None | False | 1111.32 | 0 |
| 2939866 | 97113 | None | code26 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GOK CSOR-2022 VOLUME II. No.8.33.3 P.No.47 | Sqm | 111.3 | 111.3 | 48.8 | False | None | None | False | None | False | 5431.44 | 0 |
| 2939867 | 97113 | None | code27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground Floor ---- As per directions of engineer in charge of work. GOK CSOR-2022 VOLUME II. No.9.24 P.No.63 | Sqm | 3013.5 | 3013.5 | 35.3403 | False | None | None | False | None | False | 106497.99405 | 0 |
| 2939868 | 97113 | None | code28 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge GOK CSOR-2022 VOLUME II. No.10.2 P.No.69 | Sqm | 282.45 | 282.45 | 50.21 | False | None | None | False | None | False | 14181.8145 | 0 |
| 2939869 | 97113 | None | code29 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm Ground Floor ---- As per directions of engineer in charge of work. GOK CSOR-2022 VOLUME II. No.9.17.2 P.No.61 | Sqm | 1157.1 | 1157.1 | 149.8652 | False | None | None | False | None | False | 173409.02292 | 0 |
| 2939870 | 97113 | None | code30 | Providing and laying heavy duty cobble stones 60mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level , including cost of materials, labour and Usage charges of machinery complete as per specifications. GOK CSOR-2022 VOLUME II. No.9.31 P.No.64 | Sqm | 1141.35 | 1141.35 | 60.512 | False | None | None | False | None | False | 69065.3712 | 0 |
| 2939871 | 97113 | None | code31 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1022.7 | 1022.7 | 11.34 | False | None | None | False | None | False | 11597.418 | 0 |
| 2939872 | 97113 | None | code32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. GOK CSOR-2022 VOLUME II. No.9.9 P.No.60 | Sqm | 635.25 | 635.25 | 3.6 | False | None | None | False | None | False | 2286.9 | 0 |
| 2939873 | 97113 | None | code33 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications GOK CSOR-2022 VOLUME II. No.12.13.1 P.No.100 | Sqm | 64683.15 | 64683.15 | 0.0975 | False | None | None | False | None | False | 6306.607125 | 0 |
| 2939874 | 97113 | None | code34 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GOK CSOR-2022 VOLUME II. No.12.51 P.No.103 | Nos | 1555.05 | 1555.05 | 2.0 | False | None | None | False | None | False | 3110.1 | 0 |
| 2939875 | 97113 | None | code35 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) GOK CSOR-2022 VOLUME II. No.12.15 P.No.100 | Sqm | 4783.8 | 4783.8 | 2.1 | False | None | None | False | None | False | 10045.98 | 0 |
| 2939876 | 97113 | None | code36 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. GOK CSOR-2022 VOLUME II. No.12.54 P.No.105 | Sqm | 498.75 | 498.75 | 1.89 | False | None | None | False | None | False | 942.6375 | 0 |
| 2939877 | 97113 | None | code37 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. GOK CSOR-2022 VOLUME II. No.12.58 P.No.107 | Nos | 114.45 | 114.45 | 5.0 | False | None | None | False | None | False | 572.25 | 0 |
| 2939878 | 97113 | None | code38 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete GOK CSOR-2022 VOLUME II. No.12.63 P.No.107 | Sqm | 116.55 | 116.55 | 10.0 | False | None | None | False | None | False | 1165.5 | 0 |
| 2939879 | 97113 | None | code39 | Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm dia GOK CSOR-2022 VOLUME II. No.12.66.2 P.No.105 | m | 373.8 | 373.8 | 10.2 | False | None | None | False | None | False | 3812.76 | 0 |
| 2939880 | 97113 | None | code40 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : GOK CSOR-2022 VOLUME II. No.12.72 P.No.108 | Each | 37.8 | 37.8 | 5.0 | False | None | None | False | None | False | 189.0 | 0 |
| 2939881 | 97113 | None | code41 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm GOK CSOR-2022 VOLUME II. No.12.76.2 P.No.109 | Each | 286.65 | 286.65 | 5.0 | False | None | None | False | None | False | 1433.25 | 0 |
| 2939882 | 97113 | None | code42 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 100x58x1.90mmGOK CSOR-2022 VOLUME II. No.12.74.2 P.No.108 | Each | 76.65 | 76.65 | 5.0 | False | None | None | False | None | False | 383.25 | 0 |
| 2939883 | 97113 | None | code43 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GOK CSOR-2022 VOLUME II. No.11.6.1 P.No.76 | Sqm | 2635.5 | 2635.5 | 6.0 | False | None | None | False | None | False | 15813.0 | 0 |
| 2939884 | 97113 | None | code44 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GOK CSOR-2022 VOLUME II. No.12.89 P.No.109 | Sqm | 7058.1 | 7058.1 | 13.5 | False | None | None | False | None | False | 95284.35 | 0 |
| 2939885 | 97113 | None | code45 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GOK CSOR-2022 VOLUME II. No.12.85 P.No.108 | Sqm | 5113.5 | 5113.5 | 0.345 | False | None | None | False | None | False | 1764.1575 | 0 |
| 2939886 | 97113 | None | code46 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. GOK CSOR-2022 VOLUME II. No.11.34B P.No.85 | Kg | 150.15 | 150.15 | 412.965 | False | None | None | False | None | False | 62006.69475 | 0 |
| 2939887 | 97113 | None | code47 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GOK CSOR-2022 VOLUME II. No.11.26.1 P.No.82 | Kg | 115.5 | 115.5 | 571.158 | False | None | None | False | None | False | 65968.749 | 0 |
| 2939888 | 97113 | None | code48 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.GOK CSOR-2022 VOLUME II. No.15.1 P.No.131 | Sqm | 782.25 | 782.25 | 95.4892 | False | None | None | False | None | False | 74696.4267 | 0 |
| 2939889 | 97113 | None | code49 | Providing & Fixing of Mineral Fibre Suspended Ceiling System in the module size of 600x600x19mm with Exposed grid for Hospitals, Shopping malls, Commercial establishments and office complexes. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance 87%, Thermal Conductivity k = 0.052 - 0.057 w/m K, NRC -0.7,Colour White, Fire Performance UK A2 S1, dO, with Anti Microbial coating on the face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with cleanroom class of ISO 5 (Class 100), Decontamination Class of CP1Oand Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D-4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2& pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with suspension system of approved make | Sqm | 1948.8 | 1948.8 | 54.8119 | False | None | None | False | None | False | 106817.43072 | 0 |
| 2939890 | 97113 | None | code50 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/ beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion GOK CSOR-2022 VOLUME II. No.10.15.1 P.No.71 | Sqm | 4135.95 | 4135.95 | 50.028 | False | None | None | False | None | False | 206913.3066 | 0 |
| 2939891 | 97113 | None | code51 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6 12 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement GOK CSOR-2022 VOLUME II. No.18.3 P.No.159 | Sqm | 2836.05 | 2836.05 | 15.0084 | False | None | None | False | None | False | 42564.57282 | 0 |
| 2939892 | 97113 | None | code52 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work- Exposed on wall 32mm dia Pipes, GOK CSOR-2022 VOLUME II. No.13.31.4 Addendum | Mtr | 412.65 | 412.65 | 50.0 | False | None | None | False | None | False | 20632.5 | 0 |
| 2939893 | 97113 | None | code53 | Providing and Fixing Chlorinated Polyvinyl Chloride(CPVC) Pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Conceled work, including cutting chases and making good the walls etc. 20mm dia Pipes., GOK CSOR-2022 VOLUME II. No.13.32.2 Addendum | Mtr | 391.65 | 391.65 | 20.0 | False | None | None | False | None | False | 7833.0 | 0 |
| 2939894 | 97113 | None | code54 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 for rain water, GOK CSOR-2022 VOLUME V. I.No.M010G Page 134 | l | 413.7 | 413.7 | 43.5 | False | None | None | False | None | False | 17995.95 | 0 |
| 2939895 | 97113 | None | code55 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, Confirming to ISI:12701, Colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & Over flow pipes. the base support i/c fittings and fixtures for tank shall be paid separately., GOK CSOR-2022 VOLUME II. No.13.34A Addendum | l | 8.92 | 8.92 | 1000.0 | False | None | None | False | None | False | 8920.0 | 0 |
| 2939896 | 97113 | None | code56 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :40 mm nominal bor, GOK CSOR-2022 VOLUME II. No.13.4.3 P.No.115 | Nos | 715.05 | 715.05 | 3.0 | False | None | None | False | None | False | 2145.15 | 0 |
| 2939897 | 97113 | None | code57 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g., GOK CSOR-2022 VOLUME II. No.13.13 P.No.117 | Nos | 707.7 | 707.7 | 4.0 | False | None | None | False | None | False | 2830.8 | 0 |
| 2939898 | 97113 | None | code58 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931, GOK CSOR-2022 VOLUME II. No.13.15 P.No.117 | Nos | 605.85 | 605.85 | 3.0 | False | None | None | False | None | False | 1817.55 | 0 |
| 2939899 | 97113 | None | code59 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid, GOK CSOR-2022 VOLUME II. No.14.3.1 P.No.123 | Each | 5255.25 | 5255.25 | 1.0 | False | None | None | False | None | False | 5255.25 | 0 |
| 2939900 | 97113 | None | code60 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern, GOK CSOR-2022 VOLUME II. No.14.5.1 P.No.122 | Each | 6959.4 | 6959.4 | 1.0 | False | None | None | False | None | False | 6959.4 | 0 |
| 2939901 | 97113 | None | code61 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps, GOK CSOR-2022 VOLUME II. No.14.7.1 P.No.122 | Each | 2655.45 | 2655.45 | 1.0 | False | None | None | False | None | False | 2655.45 | 0 |
| 2939902 | 97113 | None | code62 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm, GOK CSOR-2022 VOLUME II. No.14.32.2 P.No.126 | Each | 912.45 | 912.45 | 1.0 | False | None | None | False | None | False | 912.45 | 0 |
| 2939903 | 97113 | None | code63 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe, GOK CSOR-2022 VOLUME II. No.14.28.2.2 P.No.128 | Each | 228.9 | 228.9 | 3.0 | False | None | None | False | None | False | 686.7 | 0 |
| 2939904 | 97113 | None | code64 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms, GOK CSOR-2022 VOLUME II. No.14.38 P.No.129 | Each | 121.8 | 121.8 | 1.0 | False | None | None | False | None | False | 121.8 | 0 |
| 2939905 | 97113 | None | code65 | Constructing brick masonry chamber of internal dimension 450x300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.., GOK CSOR-2022 VOLUME II. No.T130D P.No.187 | Each | 3402.0 | 3402.0 | 5.0 | False | None | None | False | None | False | 17010.0 | 0 |
| 2939906 | 97113 | None | code66 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges andsuch simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m, GOK CSOR-2022 VOLUME II. No.1.4.1 P.No.5 | Cum | 195.3 | 195.3 | 18.9 | False | None | None | False | None | False | 3691.17 | 0 |
| 2939907 | 97113 | None | code67 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications, GOK CSOR-2022 VOLUME II. No.1.10 P.No.5 | Cum | 128.1 | 128.1 | 9.18 | False | None | None | False | None | False | 1175.958 | 0 |
| 2939908 | 97113 | None | code68 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates, GOK CSOR-2022 VOLUME I. No.2.1.2 P.No.A(67) | Cum | 5632.2 | 5632.2 | 3.186 | False | None | None | False | None | False | 17944.1892 | 0 |
| 2939909 | 97113 | None | code69 | Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe ........ mm dia ........ thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick, GOK SR for Electrical Works 2022-23. No.1.2.2 P.No.01 | Mtr | 70.0 | 70.0 | 150.4803 | False | None | None | False | None | False | 10533.621 | 0 |
| 2939910 | 97113 | None | code70 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet, Short point upto 3Mtr from tapping point to out let via switch box, GOK SR for Electrical Works 2022-23. No.2.2.1 P.No.03 | Mtr | 251.0 | 251.0 | 3.0 | False | None | None | False | None | False | 753.0 | 0 |
| 2939911 | 97113 | None | code71 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box , GOK SR for Electrical Works 2022-23. No.2.2.2 P.No.03 | Mtr | 361.0 | 361.0 | 9.0 | False | None | None | False | None | False | 3249.0 | 0 |
| 2939912 | 97113 | None | code72 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box, GOK SR for Electrical Works 2022-23. No.2.2.3 P.No.03 | Mtr | 542.0 | 542.0 | 5.0 | False | None | None | False | None | False | 2710.0 | 0 |
| 2939913 | 97113 | None | code73 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmm, GOK SR for Electrical Works 2022-23. No.2.3.2 P.No.03 | Mtr | 26.0 | 26.0 | 500.0 | False | None | None | False | None | False | 13000.0 | 0 |
| 2939914 | 97113 | None | code74 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmm, GOK SR for Electrical Works 2022-23. No.2.3.3 P.No.03 | Mtr | 40.0 | 40.0 | 500.0 | False | None | None | False | None | False | 20000.0 | 0 |
| 2939915 | 97113 | None | code75 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmm, GOK SR for Electrical Works 2022-23. No.2.3.4 P.No.03 | Mtr | 59.0 | 59.0 | 200.0 | False | None | None | False | None | False | 11800.0 | 0 |
| 2939916 | 97113 | None | code76 | supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall (15/3.5) 4-5 way, GOK SR for Electrical Works 2022-23. No.3.4.2 P.No.05 | Mtr | 138.0 | 138.0 | 2.0 | False | None | None | False | None | False | 276.0 | 0 |
| 2939917 | 97113 | None | code77 | supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall (15/3.5) 8 way, GOK SR for Electrical Works 2022-23. No.3.4.4 P.No.05 | Mtr | 250.0 | 250.0 | 10.0 | False | None | None | False | None | False | 2500.0 | 0 |
| 2939918 | 97113 | None | code78 | supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall (15/3.5) 10-12 way, GOK SR for Electrical Works 2022-23. No.3.4.5 P.No.05 | Mtr | 325.0 | 325.0 | 7.0 | False | None | None | False | None | False | 2275.0 | 0 |
| 2939919 | 97113 | None | code79 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4Module, GOK SR for Electrical Works 2022-23. No.3.5.2 P.No.05 | Mtr | 175.0 | 175.0 | 2.0 | False | None | None | False | None | False | 350.0 | 0 |
| 2939920 | 97113 | None | code80 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8Module, GOK SR for Electrical Works 2022-23. No.3.5.4 P.No.05 | Mtr | 302.0 | 302.0 | 10.0 | False | None | None | False | None | False | 3020.0 | 0 |
| 2939921 | 97113 | None | code81 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12Module, GOK SR for Electrical Works 2022-23. No.3.5.5 P.No.05 | Mtr | 363.0 | 363.0 | 7.0 | False | None | None | False | None | False | 2541.0 | 0 |
| 2939922 | 97113 | None | code82 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way Switch, GOK SR for Electrical Works 2022-23. No.3.6.1 P.No.05 | Mtr | 88.0 | 88.0 | 110.0 | False | None | None | False | None | False | 9680.0 | 0 |
| 2939923 | 97113 | None | code83 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch, GOK SR for Electrical Works 2022-23. No.3.6.2 P.No.05 | Mtr | 152.0 | 152.0 | 3.0 | False | None | None | False | None | False | 456.0 | 0 |
| 2939924 | 97113 | None | code84 | Supplying and fixing superior quality of modular/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 1293.(16/3.7) Group A 6A Three Way socket, GOK SR for Electrical Works 2022-23. No.3.6.3 P.No.05 | Mtr | 162.0 | 162.0 | 30.0 | False | None | None | False | None | False | 4860.0 | 0 |
| 2939925 | 97113 | None | code85 | Supplying and fixing superior quality of modular/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 1293.(16/3.7) Stepped Fan Regulator Two Module, GOK SR for Electrical Works 2022-23. No.3.6.4 P.No.05 | Mtr | 313.0 | 313.0 | 8.0 | False | None | None | False | None | False | 2504.0 | 0 |
| 2939926 | 97113 | None | code86 | Supplying and fixing superior quality of modular/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 1293.(16/3.7) Group A 32Amps DP Switch, GOK SR for Electrical Works 2022-23. No.3.6.10 P.No.05 | Mtr | 375.0 | 375.0 | 20.0 | False | None | None | False | None | False | 7500.0 | 0 |
| 2939927 | 97113 | None | code87 | Supplying and fixing superior quality of modular/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 1293.(16/3.7) Group A 6/16A Universal Socket, GOK SR for Electrical Works 2022-23. No.3.6.11 P.No.05 | Mtr | 249.0 | 249.0 | 15.0 | False | None | None | False | None | False | 3735.0 | 0 |
| 2939928 | 97113 | None | code88 | Supplying and fixing superior quality of modular/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 1293.(16/3.7) Group A RJ45/I.O Outlet Cat-6, GOK SR for Electrical Works 2022-23. No.3.6.13 P.No.05 | Mtr | 211.0 | 211.0 | 10.0 | False | None | None | False | None | False | 2110.0 | 0 |
| 2939929 | 97113 | None | code89 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6A Bakelite Ceiling Rose, GOK SR for Electrical Works 2022-23. No.3.14.5 P.No.05 | Mtr | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
| 2939930 | 97113 | None | code90 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6Amps Lamp Holder, GOK SR for Electrical Works 2022-23. No.3.14.6 P.No.05 | Mtr | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 |
| 2939931 | 97113 | None | code91 | Supplying and fixing regular MCB distribution boards on wall / wood board /flush mounting using required clamps bolts nuts etc with provision for fixing suitable type capacity MCB single phase /3 phase / single door with powder coated painting made out of 14 SWG MS enclosure III. Double door 4 way TP & N, GOK SR for Electrical Works 2022-23. No.5.18.11 P.No.13 | Mtr | 63.0 | 63.0 | 3.0 | False | None | None | False | None | False | 189.0 | 0 |
| 2939932 | 97113 | None | code92 | Supplying and fixing Miniature Circuit Breakers in existing MCB distribution boards using necessary fixing material and c type curve, indicator ON/OFF, energy cross -3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898.(47/6.16) 6-32Amps TPN, GOK SR for Electrical Works 2022-23. No.5.17.1 P.No.13 | Mtr | 523.0 | 523.0 | 10.0 | False | None | None | False | None | False | 5230.0 | 0 |
| 2939933 | 97113 | None | code93 | Supplying, fixing and wiring earth leakage /Miniature Circuit Breaker(ELEMCB) 240/450V upto 300mA sensivity on existing wood/panel board (47/6.18) 32-40 Amps 4 pole, GOK SR for Electrical Works 2022-23. No.5.20.3 P.No.13 | Mtr | 2826.0 | 2826.0 | 3.0 | False | None | None | False | None | False | 8478.0 | 0 |
| 2939934 | 97113 | None | code94 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model, GOK SR for Electrical Works 2022-23. No.6.3.1 P.No.22 | Mtr | 2085.0 | 2085.0 | 7.0 | False | None | None | False | None | False | 14595.0 | 0 |
| 2939935 | 97113 | None | code95 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition., GOK SR for Electrical Works 2022-23. No.11.6.2 P.No.35 | Mtr | 5651.0 | 5651.0 | 20.0 | False | None | None | False | None | False | 113020.0 | 0 |
| 2939936 | 97113 | None | code96 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 00 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W, GOK SR for Electrical Works 2022-23. No.11.4.2 P.No.34 | Mtr | 1478.0 | 1478.0 | 10.0 | False | None | None | False | None | False | 14780.0 | 0 |
| 2939937 | 97113 | None | code97 | Supplying And Fixing Metal Fan Box with Round Hook, GOK SR for Electrical Works 2022-23. No.1.12 P.No.2 | Mtr | 163.0 | 163.0 | 8.0 | False | None | None | False | None | False | 1304.0 | 0 |
| 2939938 | 97113 | None | code98 | Desktop Providing, INTEL CORE I5 PROCESSOR 1OTHGEN ,8GB RAM,1TB HDD,WINDOWS 10 PRO , KEYBOARD AND MOUSE,web camera HP 21.5” LED MONITER, 3 years Hardware and Software WARRANTY RequiredRates are taken from Gem Website | Each | 42448.0 | 42448.0 | 6.0 | False | None | None | False | None | False | 254688.0 | 0 |
| 2939939 | 97113 | None | code99 | HP MFP 2606 SDW Printer, Printers p to 20 ppm (A4) Rmpv up to 250 to 2500 Pages, 1200 * 1200 dpi memory 64 mb, Duplex with Wi-Fi Printing, 01 Toner Cartridge, 3 years Hardware WarrantyRates are taken from Gem Website | Each | 15500.0 | 15500.0 | 2.0 | False | None | None | False | None | False | 31000.0 | 0 |
| 2939940 | 97113 | None | code100 | Providing and Fixing Verneer Paneling : Over the 50mmx35mm sal wood frame work and top covered out of 4mm thick approved veneer fixed over 12mm ply finished in melomine polish, complete including cost and conveyance of all materials, labour for all items of work HGM of equipment etc.,complete as per specification.(Rate Per sq.Mtr), KSFIC 2020-21, KSFIC.T-68 | Sqm | 7380.0 | 7380.0 | 49.062 | False | None | None | False | None | False | 362077.56 | 0 |
| 2939941 | 97113 | None | code101 | Office Table: of size 4'x2.5'. Made out of 12/18mm MDF one key board and 3drawers on the right side. Table to be coveredwith 1mm laminate wherever visible. Hardware of the drawer should be telescopic channel SS handle with one lock. The table top should be made with 25mm MDF along with edge bending., KSFIC 2020-21, KSFIC.T-58 | Each | 19960.0 | 19960.0 | 7.0 | False | None | None | False | None | False | 139720.0 | 0 |
| 2939942 | 97113 | None | code102 | Office Table: of size 6'x3'or 5'x3'. Made out of 18mm MDF one key board and 3drawers on the right side. Table to be coveredwith 1mm laminate wherever visible. Hardware of the drawer should be telescopic channel SS handle with one lock. The table top should be made with 25mm MDF along with edge bending., KSFIC 2020-21, KSFIC.T-56 | Each | 29900.0 | 29900.0 | 1.0 | False | None | None | False | None | False | 29900.0 | 0 |
| 2939943 | 97113 | None | code103 | Wooden Rack : (Teak Wood) of size 6'x3'x1.5'. Made out of teak wood frame of section 2.25''x2.25'' and supporting patties of thickness 3''x1.25''. Panel to be made out of 12mm plywood with veneer on the outer side. 18mm plywood shelves will be provided inside.Entire rack to be polished outer side and painted inside. Front teak wood beading. Rack shall be neatly finished and polished., KSFIC 2020-21, KSFIC.T-70 | Each | 29640.0 | 29640.0 | 1.0 | False | None | None | False | None | False | 29640.0 | 0 |
| 2939944 | 97113 | None | code104 | Notice Board: of size 4'x3' using 18mm plywood for body,back 8mm plywood and 12mm soft board with cloth.And 5mm plain glass for door with lock,and alluminium chanal with teak wood beading. Outerside laminated sheet or veneer with polish, inner side paint or polish., KSFIC 2020-21, KSFIC.T-77 | Each | 13620.0 | 13620.0 | 1.0 | False | None | None | False | None | False | 13620.0 | 0 |
| 2939945 | 97113 | None | code105 | Conference Table : (ply wood with Laminated Top) Of size-Length 7', Width 2',Height 2.5'=02 Nos. Length 6.5', Width 2', Height 2.5'=01 No.(When 3 Table joined together make one Conference Table) Made out of 18mm plywood for Top and Front. With both side Laminated and Front side closed. Inner side shell be provided suitable vertical support of 36mm plywood. Table shall be provided with Footrest with suitable mm plywood. Table Inner side shall be polish or paint., KSFIC 2020-21, KSFIC.T-82 | Each | 88870.0 | 88870.0 | 1.0 | False | None | None | False | None | False | 88870.0 | 0 |
| 2939946 | 97113 | None | code106 | Teak Wood Bench With Back : Size : 182.88cm L x 46cm Wx 96cm H Legs 4.4x4.44cm.Patties at top and bottom around 5.68x2.54cm in section and polished seat shall be provided with 18mm block board with laminated sheet on the top board. Back with Teak wood patti., KSFIC 2020-21, KSFIC.T-91 | Each | 25840.0 | 25840.0 | 1.0 | False | None | None | False | None | False | 25840.0 | 0 |
| 2939947 | 97113 | None | code107 | Computer Chair :Stainless steel base ABS seat and back cushion with arm Hydraulic Height adjustment., KSFIC 2020-21, KSFIC.T-92 | Each | 5540.0 | 5540.0 | 23.0 | False | None | None | False | None | False | 127420.0 | 0 |
| 2939948 | 97113 | None | code108 | Director Cushion Chair : High back chair with seat and back High quality feather touch Rexine. Arms with cushioning. Chair to have SS base with 5 Caster wheel legs along with Syncro Mechanisum. , KSFIC 2020-21, KSFIC.T-94 | Each | 11280.0 | 11280.0 | 4.0 | False | None | None | False | None | False | 45120.0 | 0 |
| 2939949 | 97113 | None | code109 | Providing and fixing Storage unit : of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc.,complete the rate includes cost of all materials, labour charges, complete as per specification. (Rate Per Sq.Mtr), KSFIC 2020-21, KSFIC.T-102 | Sqm | 17620.0 | 17620.0 | 15.0 | False | None | None | False | None | False | 264300.0 | 0 |
| 2939950 | 97113 | None | code110 | Supplying ......TR split Air conditioners suitable for operation on A/C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed/ PVC copper cable and a battery operated wireless remote unit. 5Star 1 Ton Capacity, GOK SR for Electrical Works 2022-23. No.6.7.1 P.No.23 | Each | 44570.0 | 44570.0 | 4.0 | False | None | None | False | None | False | 178280.0 | 0 |
| 2939951 | 97113 | None | code111 | Supplying & Fixing of switch mounting rack with power manager & Cable manager. 18U with 650mm depth, GOK SR for Electrical Works 2022-23. No.8.4.5 P.No.28 | Mtr | 20411.0 | 20411.0 | 1.0 | False | None | None | False | None | False | 20411.0 | 0 |
| 2939952 | 97113 | None | code112 | Supplying fixing of Network Switches 24 Port 10/100 Switch, GOK SR for Electrical Works 2022-23. No.8.9.5 P.No.28 | Mtr | 5343.0 | 5343.0 | 1.0 | False | None | None | False | None | False | 5343.0 | 0 |
| 2939953 | 97113 | None | code113 | Switch Supplying & Fixing of ... ms Cat 6 Patch Cable 2m, GOK SR for Electrical Works 2022-23. No.8.11.2 P.No.28 | Mtr | 286.0 | 286.0 | 10.0 | False | None | None | False | None | False | 2860.0 | 0 |
| 2939954 | 97113 | None | code114 | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete 5 kVA OFF LINE UPS, GOK SR for Electrical Works 2022-23. No.9.2.5 P.No.29 | Mtr | 38661.0 | 38661.0 | 1.0 | False | None | None | False | None | False | 38661.0 | 0 |
| 2939955 | 97113 | None | code115 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75/ 80 AH batteries., GOK SR for Electrical Works 2022-23. No.9.5.6 P.No.29 | Mtr | 10748.0 | 10748.0 | 12.0 | False | None | None | False | None | False | 128976.0 | 0 |
| 2939956 | 97113 | None | code116 | Total Qty 2MP Progressive scan CMOS h 265 H 264 and 12 7 Progressive Scan CMOS 920 x 1080 at 30fps H265 H.265 H.264 H.264 Backlight Compensation 3D Digital Noise Reduction Region of Interest Digital Wide Dynamic Range IP67 Make:CP Plus | Nos | 3086.0 | 3086.0 | 4.0 | False | None | None | False | None | False | 12344.0 | 0 |
| 2939957 | 97113 | None | code117 | 4CH NVR Cooper 1U H.265 Network Video Recorder H.265+/H.264+ codec decoding Max 40 Mbps/ 20 Mbps incoming/ outgoing bandwidth Max 4/8 channel IP camera inputs Internal HDD: 1 SATA 3 Port, up to 4TB capacity for each HDD , GOK SR for Electrical Works 2022-23. No.1.12 P.No.2 | Nos | 9500.0 | 9500.0 | 1.0 | False | None | None | False | None | False | 9500.0 | 0 |
| 2939958 | 97113 | None | code01 | Earth work e cavation for Foundation by mechanical means for all works and depth upto 3 m as per drawing and technical specifications including setting out shoring strutting barricading caution lights including dressing of e cavated surfaces disposing off or levelling the e cavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools usage of machinery and other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m GOK CSOR 2022 VOLUME I. No. 1.14.1 P.No.8 | Cum | 76.65 | 76.65 | 223.398 | False | None | None | False | None | False | 17123.4567 | 0 |
| 2939959 | 97113 | None | code02 | Filling available e cavated earth (e cluding rock) in trenches plinth sides of foundations and other similar works etc. in layers not e ceeding 20cm in depth consolidating each deposited layer by ramming and watering lead up to 50 m and lift upto 1.5 m. GOK CSOR 2022 VOLUME I. No. 1.9 P.No.7 | Cum | 214.2 | 214.2 | 276.4073 | False | None | None | False | None | False | 59206.44366 | 0 |
| 2939960 | 97113 | None | code03 | Providing and injecting chemical emulsion for Pre constructional Anti Termite Treatment creating continuous chemical barrier under and around the column pits walls trenches basement e cavation top surface of the plinth filling junction of wall and floor along the e ternal perimeter of building e pansion joints over the top surface of consolidated earth on which apron is to be laid surrounding of pipes and conduits with Chlorpyriphos 20% E.C. Lindane 20% E.C. @ 3.19 ltr m2 including cost of chemical diluting in water to one percent concentration labour usage charges of machinery complete as per specifications. GOK CSOR 2022 VOLUME II. No. 4.1 P.No.5 | Sqm | 99.75 | 99.75 | 102.021 | False | None | None | False | None | False | 10176.59475 | 0 |
| 2939961 | 97113 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1 6 12 (1 cement 6 coarse sand 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1 6 (1 cement 6 coarse sand) GOK CSOR 2022 VOLUME II. No. 5.1.1 P.No.9 | Cum | 4987.5 | 4987.5 | 41.751 | False | None | None | False | None | False | 208233.1125 | 0 |
| 2939962 | 97113 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone in foundation and plinth with Cement mortar 1 6 (1 cement 6 coarse sand) GOK CSOR 2022 VOLUME II. No. 5.3 P.No.9 | Cum | 5457.9 | 5457.9 | 28.7631 | False | None | None | False | None | False | 156986.12349 | 0 |
| 2939963 | 97113 | None | code06 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mi ed laid in layers not e ceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mi 1 4 8( M5) Using 40 mm and down size graded crushed coarse aggregates GOK CSOR 2022 VOLUME I. No.2.1.2 P.No.15 | Cum | 5466.3 | 5466.3 | 56.3019 | False | None | None | False | None | False | 307763.07597 | 0 |
| 2939964 | 97113 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mi ed with super plasticizers laid in finished layers well compacted using needle vibrators including all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mi Using 20 mm and down size graded crushed coarse aggregates GOK CSOR 2022 VOLUME I. No.2.2.1.1 P.No.15 | Cum | 6240.15 | 6240.15 | 40.246 | False | None | None | False | None | False | 251141.0769 | 0 |
| 2939965 | 97113 | None | code08 | Providing and laying in position Reinforced cement concrete for all Super structures of building Road works Water works Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mi ed with super plasticisers laid in layers well compacted using needle vibrators. The cost includes finsishing concrete structure in line all lead and lifts cost of all materials quality confirming to the requirements of relevant IS codes labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement dowel bars and formwork to be paid separately) M20 Design Mi Using 20 mm and down size graded crushed coarse aggregates GOK CSOR 2022 VOLUME I. No.2.5.1 P.No.17 | Cum | 6491.1 | 6491.1 | 60.289 | False | None | None | False | None | False | 391341.9279 | 0 |
| 2939966 | 97113 | None | code09 | Providing and laying in Reinforced cement concrete for all Basement and surface level works return walls retaining walls sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mi ed with super plasticisers laid in layers not e ceeding 150 mm thickness well compacted using needle vibrators providing weep holes wherever necesary including all lead and lifts cost of all materials of quality labour Usage charges of machinery curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M20 Design Mi Using 20 mm and down size graded crushed coarse aggregates GOK CSOR 2022 VOLUME I. No.2.3.1 P.No.16 | Cum | 6266.4 | 6266.4 | 13.5042 | False | None | None | False | None | False | 84622.71888 | 0 |
| 2939967 | 97113 | None | code10 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1 6 (1 cement 6 coarse sand) including cost of all materials labour scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work. GOK CSOR 2022 VOLUME II. No.6.8 P.No.14 | Cum | 7024.5 | 7024.5 | 73.448 | False | None | None | False | None | False | 515935.476 | 0 |
| 2939968 | 97113 | None | code11 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1 4 (1 cement 4 coarse sand) including cost of all materials labour scaffolding and usage charges of machinery and other incidental charges complete as per the direction of engineer incharge of work GOK CSOR 2022 VOLUME II. No.6.15 P.No.14 | Sqm | 909.3 | 909.3 | 7.84 | False | None | None | False | None | False | 7128.912 | 0 |
| 2939969 | 97113 | None | code12 | Providing Thermo Mechanically Treated bars of grade Fe 500D or more Steel reinforcement for R.C.C. work including straightening cut ting bending placing in position binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material labour usage charges complete as per specifications. (The laps and wastages shall not be measured separately) GOK CSOR 2022 VOLUME II. No.11.32 P.No.84 | Kg | 96.6 | 96.6 | 8042.81 | False | None | None | False | None | False | 776935.446 | 0 |
| 2939970 | 97113 | None | code13 | Providing and fi ing Shuttering for Footing Beams Columns and Slab. (GOK PWD SOR BUILDINGS 2022 Preface No.22 P.No.(A) 17) GOK PWD SOR BUILDINGS 2022 Preface No.22 P.No.(A) 17 Rate for Shuttering of Footing | Sqm | 499.21 | 499.21 | 29.16 | False | None | None | False | None | False | 14556.9636 | 0 |
| 2939971 | 97113 | None | code14 | Rate for RCC Beams Lintels | Sqm | 3894.66 | 3894.66 | 11.8162 | False | None | None | False | None | False | 46020.081492 | 0 |
| 2939972 | 97113 | None | code15 | Rate for RCC Plinth Beams Roof (Straight) | Sqm | 499.21 | 499.21 | 37.4536 | False | None | None | False | None | False | 18697.211656 | 0 |
| 2939973 | 97113 | None | code16 | Rate for RCC Columns and Piers | Sqm | 499.21 | 499.21 | 21.4751 | False | None | None | False | None | False | 10720.584671 | 0 |
| 2939974 | 97113 | None | code17 | Rate for RCC Chejja Canopy and other Architectural Projections | Sqm | 499.21 | 499.21 | 0.63 | False | None | None | False | None | False | 314.5023 | 0 |
| 2939975 | 97113 | None | code18 | Providing 12 mm cement plaster with cement mortar 1 4 (1 cement 4 fine sand) including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge. for ceiling Ground Floor As per directions of engineer in charge of work. GOK PWD SOR BUILDINGS 2022 VOLUME II. No.8.1.1 P.No.41 | Sqm | 223.65 | 223.65 | 83.3311 | False | None | None | False | None | False | 18637.000515 | 0 |
| 2939976 | 97113 | None | code19 | Providing 15 mm cement plaster with cement mortar 1 4 (1 cement 4 fine sand) including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge. for ceiling Ground Floor As per directions of engineer in charge of work. GOK PWD SOR BUILDINGS 2022 VOLUME II. No.8.2.1 P.No.41 | Sqm | 260.4 | 260.4 | 270.3889 | False | None | None | False | None | False | 70409.26956 | 0 |
| 2939977 | 97113 | None | code20 | Providing 18 mm cement plaster of mi 1 4 (1 cement 4 fine sand) to brick stone masonary including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per specifications and as per directions of Engineer in charge. GOK PWD SOR BUILDINGS 2022 VOLUME II. No.8.3.1 P.No.41 | Sqm | 313.95 | 313.95 | 578.706 | False | None | None | False | None | False | 181684.7487 | 0 |
| 2939978 | 97113 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. GOK CSOR 2022 VOLUME II. No.8.51 P.No.50 | Sqm | 87.15 | 87.15 | 353.72 | False | None | None | False | None | False | 30826.698 | 0 |
| 2939979 | 97113 | None | code22 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge. GOVERNAMENT OF KARNTAKA PWD CSOR 2022 I.NO 8.27 P.NO 45 | Sqm | 42.0 | 42.0 | 353.72 | False | None | None | False | None | False | 14856.24 | 0 |
| 2939980 | 97113 | None | code23 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade Two coats on new work after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge. for inside walls Ground Floor As per directions of engineer in charge of work. GOK CSOR 2022 VOLUME II. No.8.39 P.No.48 | Sqm | 99.75 | 99.75 | 353.72 | False | None | None | False | None | False | 35283.57 | 0 |
| 2939981 | 97113 | None | code24 | Finishing walls with Premium Acrylic Smooth e terior paint with Silicone additives of required shade New work (Two coats applied @ 1.43 ltr 10 m over and including priming coat of e terior primer applied @ 2.20 kg 10 m) with paint of approved quality to give an even shade after thoroughly brooming the surface to remove all dirt dust mortar drops and foreign matter including preparing the surface even and sand paper smooth cost of materials labour complete as per specifications and as per directions of Engineer in charge. Ground Floor As per directions of engineer in charge of work. GOK CSOR 2022 VOLUME II. No.8.30 P.No.46 | Sqm | 142.8 | 142.8 | 578.706 | False | None | None | False | None | False | 82639.2168 | 0 |
| 2939982 | 97113 | None | code25 | Painting wood work with Delu e Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @0.75 ltr 10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil grease dirt and foreign matter sand papering and knotting cost of materials labour complete as per specifications and as per directions of Engineer in charge. GOK CSOR 2022 VOLUME II. No.8.33.2 P.No.46 | Sqm | 110.25 | 110.25 | 18.72 | False | None | None | False | None | False | 2063.88 | 0 |
| 2939983 | 97113 | None | code26 | Painting Steel work with Delu e Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil grease dirt and foreign matter cost of materials labour complete as per specifications and as per directions of Engineer in charge. GOK CSOR 2022 VOLUME II. No.8.33.3 P.No.47 | Sqm | 111.3 | 111.3 | 44.3 | False | None | None | False | None | False | 4930.59 | 0 |
| 2939984 | 97113 | None | code27 | Providing and laying Polished Granite stone flooring in required design and patterns in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1 4 (1 cement 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admi ed with pigment of matching shade including rubbing curing and polishing etc. all complete as specified and as directed by the Engineer in Charge. ** Polished Granite stone slab Black Cherry Red Brown Cat Eye River Pink or equivalent. Ground Floor As per directions of engineer in charge of work. GOK CSOR 2022 VOLUME II. No.9.24 P.No.63 | Sqm | 3013.5 | 3013.5 | 71.499 | False | None | None | False | None | False | 215462.2365 | 0 |
| 2939985 | 97113 | None | code28 | Providing edge moulding to 18mm thick Granite stone counters vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer in charge GOK CSOR 2022 VOLUME II. No.10.2 P.No.69 | m | 282.45 | 282.45 | 96.56 | False | None | None | False | None | False | 27273.372 | 0 |
| 2939986 | 97113 | None | code29 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622 of approved make in all colours and shade over 12 mm thick bed of cement mortar 1 3 (1 cement 3 coarse sand) jointing with grey cement slurry @ 3.3 kg m2 including grouting the joint with white cement and matching pigments etc. complete. Size of Tile 600 600 mm Ground Floor As per directions of engineer in charge of work. GOK CSOR 2022 VOLUME II. No.9.17.2 P.No.61 | Sqm | 1157.1 | 1157.1 | 102.4584 | False | None | None | False | None | False | 118554.61464 | 0 |
| 2939987 | 97113 | None | code30 | Providing and laying heavy duty cobble stones 60mm thick interlock pavers using cement and course sand for manufacture of blocks of approved size shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints final compaction of paver surface joints into its final level including cost of materials labour and Usage charges of machinery complete as per specifications. GOK CSOR 2022 VOLUME II. No.9.31 P.No.64 | Sqm | 1141.35 | 1141.35 | 242.4556 | False | None | None | False | None | False | 276726.69906 | 0 |
| 2939988 | 97113 | None | code31 | Providing and fi ing 1st quality ceramic glazed wall tiles conforming to IS 15622 (thickness to be specified by the manufacturer) of approved make in all colours shades e cept burgundy bottle green black of any size as approved by Engineer in Charge in skirting risers of steps and dados over 12 mm thick bed of cement mortar 1 3 (1 cement 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mi ed with pigment of matching shade complete. GOK CSOR 2022 VOLUME II. No.10.74 P.No.71 | Sqm | 800.09 | 800.09 | 16.38 | False | None | None | False | None | False | 13105.4742 | 0 |
| 2939989 | 97113 | None | code32 | Providing and laying Ceramic glazed floor tiles of size 300 300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS 15622 of approved make in colours such as White Ivory Grey Fume Red Brown laid on 20 mm thick cement mortar 1 4 (1 Cement 4 Coarse sand) Jointing with grey cement slurry @ 3.3 kg m2 including pointing the joints with white cement and matching pigment etc. complete. GOK CSOR 2022 VOLUME II. No.9.9 P.No.60 | Sqm | 635.25 | 635.25 | 3.6 | False | None | None | False | None | False | 2286.9 | 0 |
| 2939990 | 97113 | None | code33 | Providing Salwood frames of doors windows clerestory windows ventilators and other frames wrought framed or assembled including making plaster groves ( e cluding cost of cement concrete and side clamps ) but including cost of materials labour usage charges complete as per specifications GOK CSOR 2022 VOLUME II. No.12.13.1 P.No.98 | Sqm | 64683.15 | 64683.15 | 0.1657 | False | None | None | False | None | False | 10717.997955 | 0 |
| 2939991 | 97113 | None | code34 | Fi ing of door frame in an e isting opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1 3 6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials labour charges complete as per specifications. GOK CSOR 2022 VOLUME II. No.12.51 P.No.103 | Nos | 1555.0 | 1555.0 | 4.0 | False | None | None | False | None | False | 6220.0 | 0 |
| 2939992 | 97113 | None | code35 | Providing and fi ing in position fully panelled Mathi Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials labour usage charges complete as per specifications. ( e cluding cost of fi tures ) GOK CSOR 2022 VOLUME II. No.12.15 P.No.98 | Sqm | 4783.8 | 4783.8 | 7.14 | False | None | None | False | None | False | 34156.332 | 0 |
| 2939993 | 97113 | None | code36 | Providing and fi ing factory made PVC Door frame of size 50 47mm with a wall thickness of 5mm made out of e truded 5mm rigid PVC foam sheet metered cut at corners and jointed 2 No.s of 150mm long brackets of 15 15mm M.S Square tube the entire door frame to be reinforced with 19 19mm M.S Square tube of 19 gauge. The door frame to be fi ed to the wall using M.S. Screws of 65 80mm size complete as per manufacturers specification and direction of Engineer in charge. GOK CSOR 2022 VOLUME II. No.12.54 P.No.103 | Sqm | 498.75 | 498.75 | 2.1 | False | None | None | False | None | False | 1047.375 | 0 |
| 2939994 | 97113 | None | code37 | Providing and fi ing bright finished brass hanging type floor door stopper with necessary screws etc. complete. GOK CSOR 2022 VOLUME II. No.12.58 P.No.105 | Nos | 114.45 | 114.45 | 4.0 | False | None | None | False | None | False | 457.8 | 0 |
| 2939995 | 97113 | None | code38 | Providing and fi ing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete GOK CSOR 2022 VOLUME II. No.12.63 P.No.105 | Sqm | 116.52 | 116.52 | 8.0 | False | None | None | False | None | False | 932.16 | 0 |
| 2939996 | 97113 | None | code39 | Providing and fi ing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fi ed with C.P. brass screws and PVC sleeves etc. wherever necessary complete 20mm dia GOK CSOR 2022 VOLUME II. No.12.66 P.No.105 | m | 373.8 | 373.8 | 11.2 | False | None | None | False | None | False | 4186.56 | 0 |
| 2939997 | 97113 | None | code40 | Providing and fi ing ISI marked o idised M.S. tower bolt black finish (Barrel type) with necessary screws etc. complete GOK CSOR 2022 VOLUME II. No.12.72 P.No.105 | Each | 37.8 | 37.8 | 1.0 | False | None | None | False | None | False | 37.8 | 0 |
| 2939998 | 97113 | None | code41 | Providing and fi ing bright finished brass tower bolts (barrel type) with necessary screws etc. complete 200 10mm GOK CSOR 2022 VOLUME II. No.12.76.2 P.No.107 | Each | 286.65 | 286.65 | 4.0 | False | None | None | False | None | False | 1146.6 | 0 |
| 2939999 | 97113 | None | code42 | Providing and fi ing IS 12817 marked stainless steel butt hinges with stainless steel screws etc. complete 100 58 1.90mm GOK CSOR 2022 VOLUME II. No.12.74.2 P.No.106 | Nos | 76.65 | 76.65 | 12.0 | False | None | None | False | None | False | 919.8 | 0 |
| 2940000 | 97113 | None | code43 | Supplying and fi ing rolling shutters of approved make made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fi ing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 part 1 and M.S. top cover of required thickness for rolling shutters. 80 1.25 mm M.S. laths with 1.25mm thick top cover including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge. GOK CSOR 2022 VOLUME II. No.11.6.1 P.No.76 | Sqm | 2635.5 | 2635.5 | 10.24 | False | None | None | False | None | False | 26987.52 | 0 |
| 2940001 | 97113 | None | code44 | Providing and fi ing of 2.5 track 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dio ide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 94mm width 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm 42mm. Coe truded Glazing bead for fi ing of glass shall be of size 20mm 24 mm. Windows shall be provided with 5mm plain float glass standard hardware and single point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm 2.5mm. Ma imum possible size 1819mm 1819mm. (The cost is inclusive of all fi tures and separate charges for minor TandP's shall not be made) GOK CSOR 2022 VOLUME II. No.12.89 P.No.109 | Sqm | 7058.1 | 7058.1 | 15.75 | False | None | None | False | None | False | 111165.075 | 0 |
| 2940002 | 97113 | None | code45 | Providing and fi ing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dio ide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame. The frame having overall size of 39mm 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fi ing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Ma imum possible size 1000mm 1000mm.(The cost is inclusive of all fi tures and separate charges for minor TandP's shall not be made) GOK CSOR 2022 VOLUME II. No.12.85 P.No.108 | Sqm | 5113.5 | 5113.5 | 0.345 | False | None | None | False | None | False | 1764.1575 | 0 |
| 2940003 | 97113 | None | code46 | Providing and fi ing M.S. grills of required pattern in frames of windows etc. with M.S. flats square or round bars etc. including priming coat with approved steel primer all complete. Fi ed to openings wooden frames with rawl plugs screws etc. GOK CSOR 2022 VOLUME II. No.11.34B P.No.85 | Kg | 150.15 | 150.15 | 330.75 | False | None | None | False | None | False | 49662.1125 | 0 |
| 2940004 | 97113 | None | code47 | Providing and fi ing hand rail of approved size by welding etc. to steel ladder railing balcony railing staircase railing and similar works including applying priming coat of approved steel primer. M.S. tube including cost of materials labour usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge. GOK CSOR 2022 VOLUME II. No.11.26.1 P.No.82 | Kg | 116.41 | 116.41 | 346.5 | False | None | None | False | None | False | 40336.065 | 0 |
| 2940005 | 97113 | None | code48 | Providing and Fi ing of Mineral Fibre Suspended Ceiling System in the module size of 600 600 19mm with E posed grid for Hospitals Shopping malls Commercial establishments and office comple es. The tiles should have Humidity Resistance (RH) of 99% Light Reflectance 87% Thermal Conductivity k = 0.052 0.057 w m K NRC 0.7 Colour White Fire Performance UK A2 S1 dO with Anti Microbial coating on the face of the tile suitable for zone 4 area according to NF S 90 35 2003 with cleanroom class of ISO 5 (Class 100) Decontamination Class of CP1Oand Bacteriological Cleanliness Class B1 for specific strains and reduction in colony size. Washability properties of 500 wash cycles as per ASTM D 4828 and suitable for Green Building application with Recycled content of 37%. The tile shall be laid on 24mm wide T section flanges colour white having rotary stitching on all T sections i.e. the Main Runner 1200 mm and 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg m2and pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 grams per m2 and need to be installed with suspension system of approved make GOK CSOR 2022 VOLUME II. No.7.50 P.No.32 | Sqm | 1948.8 | 1948.8 | 56.62 | False | None | None | False | None | False | 110341.056 | 0 |
| 2940006 | 97113 | None | code49 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC Bathroom cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epo y primer @150 g per m2 and protection with 120gsm Geo te tile over the waterproofing membrane. The finished cost to include surface preparation making coving at Junction Bore Packing treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. GOK CSOR 2022 VOLUME II. No.15.1 P.No.131 | Sqm | 782.25 | 782.25 | 123.961 | False | None | None | False | None | False | 96968.49225 | 0 |
| 2940007 | 97113 | None | code50 | Providing and fi ing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50 25 4mm C section or equivalent. The panel should consist of 3mm thick non halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119 12 and clause B S1 do as per ENT 13501 1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fi ed using GI brackets aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories sealing shall be done with necessary rods etc. complete For Straight Portion GOK CSOR 2022 VOLUME II. No.10.15.1 P.No.71 | Sqm | 4135.95 | 4135.95 | 58.656 | False | None | None | False | None | False | 242598.2832 | 0 |
| 2940008 | 97113 | None | code51 | Providing assembling and supplying vision glass panels (IGUs) comprising of hermetically sealed 6 12 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified comprising of an outer heat strengthened float glass 6mm thick of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade an inner Heat strengthned clear float glass 6mm thick spacer tube 12mm wide dessicants including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances as per the Architectural drawings as per the approved shop drawings as specified and as directed by the Engineer in Charge. The IGUs shall be assembled in the factory workshop of the glass processor.(Payment for fi ing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment only the actual area of glass on face 1 of the glass panels (e cluding the areas of the grooves and weather silicone sealant) provided and fi ed in position shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2 + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 % Light reflection internal 10 to 15% light reflection e ternal 10 to 20 % shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement GOK CSOR 2022 VOLUME II. No.18.3 P.No.159 | Sqm | 2836.05 | 2836.05 | 17.5968 | False | None | None | False | None | False | 49905.40464 | 0 |
| 2940009 | 97113 | None | code52 | Providing and Fi ing Chlorinated Polyvinyl Chloride(CPVC) Pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fi ing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of Internal work E posed on wall 32mm dia Pipes GOK CSOR 2022 VOLUME II. No.13.31.4 Addendum | Mtr | 412.65 | 412.65 | 70.0 | False | None | None | False | None | False | 28885.5 | 0 |
| 2940010 | 97113 | None | code53 | Providing and Fi ing Chlorinated Polyvinyl Chloride(CPVC) Pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fi ing the pipe with clamps at 1.0m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. Conceled work including cutting chases and making good the walls etc. 20mm dia Pipes. GOK CSOR 2022 VOLUME II. No.13.32.2 Addendum | Mtr | 391.65 | 391.65 | 30.0 | False | None | None | False | None | False | 11749.5 | 0 |
| 2940011 | 97113 | None | code54 | Supplying PVC ringtite pipes conforming to IS 4985 2000 with latest amendments and conveying to worksite rolling and lowering into trenches laying true to line and level and perfect linking at joints testing and commissioning including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (e cluding cost of specials) with jointing of approved type with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the e cavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 110mm dia. 6 kg sqcm and class 3 for rain water GOK CSOR 2022 VOLUME V. I.No.M010G Page 134 | l | 413.7 | 413.7 | 54.0 | False | None | None | False | None | False | 22339.8 | 0 |
| 2940012 | 97113 | None | code55 | Providing and fi ing rectangular high density polyethylene water storage loft tank with cover Confirming to ISI 12701 Colour of opaque white or as approved by Engineer in charge. The rate includes making necessary holes for inlet outlet and Over flow pipes. the base support i c fittings and fi tures for tank shall be paid separately. GOK CSOR 2022 VOLUME II. No.13.34A Addendum | l | 8.92 | 8.92 | 999.9999 | False | None | None | False | None | False | 8919.999108 | 0 |
| 2940013 | 97113 | None | code56 | Providing and fi ing Brass full way valve gate with C.I. wheel of approved quality (screwed end) 40 mm nominal bor GOK CSOR 2022 VOLUME II. No.13.4.3 P.No.115 | Nos | 715.05 | 715.05 | 4.0 | False | None | None | False | None | False | 2860.2 | 0 |
| 2940014 | 97113 | None | code57 | Providing and fi ing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. GOK CSOR 2022 VOLUME II. No.13.13 P.No.117 | Nos | 707.7 | 707.7 | 7.0 | False | None | None | False | None | False | 4953.9 | 0 |
| 2940015 | 97113 | None | code58 | Providing and fi ing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS 8931 GOK CSOR 2022 VOLUME II. No.13.15 P.No.117 | Nos | 605.85 | 605.85 | 5.0 | False | None | None | False | None | False | 3029.25 | 0 |
| 2940016 | 97113 | None | code59 | Providing and fi ing white vitreous china pedestal type water closet (European type) with seat and lid 10 litre low level white vitreous china flushing cistern and C.P. flush bend with fittings and C.I. brackets 40 mm flush bend overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid GOK CSOR 2022 VOLUME II. No.14.3.1 P.No.123 | Each | 5255.25 | 5255.25 | 2.0 | False | None | None | False | None | False | 10510.5 | 0 |
| 2940017 | 97113 | None | code60 | Providing and fi ing white vitreous china flat back half stall urinal of size 580 380 350 mm with white PVC automatic flushing cistern with fittings standard size C.P. brass flush pipe spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS 2556 C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C. automatic flushing cistern GOK CSOR 2022 VOLUME II. No.14.5.1 P.No.122 | Each | 6959.4 | 6959.4 | 2.0 | False | None | None | False | None | False | 13918.8 | 0 |
| 2940018 | 97113 | None | code61 | Providing and fi ing wash basin with C.I. brackets 15 mm C.P. brass pillar taps 32 mm C.P. brass waste of standard pattern including painting of fittings and brackets cutting and making good the walls wherever require White Vitreous China Wash basin size 630 450 mm with a pair of 15 mm C.P. brass pillar taps GOK CSOR 2022 VOLUME II. No.14.7.1 P.No.122 | Each | 2655.45 | 2655.45 | 2.0 | False | None | None | False | None | False | 5310.9 | 0 |
| 2940019 | 97113 | None | code62 | Providing and fi ing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453 357 mm GOK CSOR 2022 VOLUME II. No.14.32.2 P.No.126 | Each | 912.45 | 912.45 | 1.0 | False | None | None | False | None | False | 912.45 | 0 |
| 2940020 | 97113 | None | code63 | Providing and fi ing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Fle ible pipe GOK CSOR 2022 VOLUME II. No.14.28.2.2 P.No.128 | Each | 228.9 | 228.9 | 6.0 | False | None | None | False | None | False | 1373.4 | 0 |
| 2940021 | 97113 | None | code64 | Providing and fi ing PTMT liquid soap container 109 mm wide 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms GOK CSOR 2022 VOLUME II. No.14.38 P.No.129 | Each | 121.8 | 121.8 | 2.0 | False | None | None | False | None | False | 243.6 | 0 |
| 2940022 | 97113 | None | code65 | Constructing brick masonry chamber of internal dimension 450 300mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1 6 bed concrete 150mm thick with 1 3 6 plastering 12 mm thick with cement mortar 1 4 CC 1 2 4 coping 75mm thk for fi ing CI cover and frame etc. e cluding the cost of CI frame and cover.. GOK CSOR 2022 VOLUME II. No.T130D P.No.187 | Each | 3402.0 | 3402.0 | 6.0 | False | None | None | False | None | False | 20412.0 | 0 |
| 2940023 | 97113 | None | code66 | Earth work e cavation by manual means for drains canals waste weir draft approach channels key trenches foundation of bridges andsuch simillar works in all kinds of soils as per drawing and technical specifications including setting out shoring strutting barricading caution lights removal of stumps and other deleterious matter e cavated surface leveled and sides neatly dressed disposing off the e cavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m GOK CSOR 2022 VOLUME II. No.1.4.1 P.No.5 | Cum | 195.3 | 195.3 | 32.4 | False | None | None | False | None | False | 6327.72 | 0 |
| 2940024 | 97113 | None | code67 | Refilling available earth around trenches pipelines cables in layers not e ceeding 20 cms in depth compacting each deposited layer by ramming after watering with a lead upto 50 m and lift upto 1.5 m. Including cost of all labour complete as per specifications GOK CSOR 2022 VOLUME II. No.1.10 P.No.5 | Cum | 128.1 | 128.1 | 9.18 | False | None | None | False | None | False | 1175.958 | 0 |
| 2940025 | 97113 | None | code68 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mi ed laid in layers not e ceeding 150 mm thickness well compacted using plate vibrators including all lead and lifts cost of all materials of quality labour Usage charges of machineries curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately) Mi 1 4 8( M5) Using 40 mm and down size graded crushed coarse aggregates GOK CSOR 2022 VOLUME I. No.2.1.2 P.No.A(67) | Cum | 5632.2 | 5632.2 | 4.05 | False | None | None | False | None | False | 22810.41 | 0 |
| 2940026 | 97113 | None | code69 | Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe ........ mm dia ........ thick confirming to IS 2509 with suitable size bends metal PVC junction bo es adhesive paste etc. and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction bo es and pipes ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. b) 25mm dia 2mm thick GOK SR for Electrical Works 2022 23. No.1.2.2 P.No.01 | Mtr | 70.0 | 70.0 | 127.1399 | False | None | None | False | None | False | 8899.793 | 0 |
| 2940027 | 97113 | None | code70 | Supplying and wiring adopting loop system in e isting PVC Conduit casing capping casing capping using 2 1.5Sqmm (Phase and Neutral) and 1 1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) without control switch shall be fi ed on the e isting plastic sheet gang bo the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Short point upto 3Mtr from tapping point to out let via switch bo GOK SR for Electrical Works 2022 23. No.2.2.1 P.No.03 | Mtr | 251.0 | 251.0 | 8.0 | False | None | None | False | None | False | 2008.0 | 0 |
| 2940028 | 97113 | None | code71 | Supplying and wiring adopting loop system in e isting PVC Conduit casing capping casing capping using 2 1.5Sqmm (Phase and Neutral) and 1 1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) without control switch shall be fi ed on the e isting plastic sheet gang bo the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch bo GOK SR for Electrical Works 2022 23. No.2.2.2 P.No.03 | Mtr | 361.0 | 361.0 | 14.0 | False | None | None | False | None | False | 5054.0 | 0 |
| 2940029 | 97113 | None | code72 | Supplying and wiring adopting loop system in e isting PVC Conduit casing capping casing capping using 2 1.5Sqmm (Phase and Neutral) and 1 1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694 and latest amendments) without control switch shall be fi ed on the e isting plastic sheet gang bo the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet Long point above 6Mtr upto 10Mtr from tapping point to out let via switch bo GOK SR for Electrical Works 2022 23. No.2.2.3 P.No.03 | Mtr | 542.0 | 542.0 | 6.0 | False | None | None | False | None | False | 3252.0 | 0 |
| 2940030 | 97113 | None | code73 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. 1.5 sqmm GOK SR for Electrical Works 2022 23. No.2.3.2 P.No.03 | Mtr | 26.0 | 26.0 | 1000.0 | False | None | None | False | None | False | 26000.0 | 0 |
| 2940031 | 97113 | None | code74 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. 2.5 sqmm GOK SR for Electrical Works 2022 23. No.2.3.3 P.No.03 | Mtr | 40.0 | 40.0 | 700.0 | False | None | None | False | None | False | 28000.0 | 0 |
| 2940032 | 97113 | None | code75 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694 confirming to latest amendments. 4 sqmm GOK SR for Electrical Works 2022 23. No.2.3.4 P.No.03 | Mtr | 59.0 | 59.0 | 400.0 | False | None | None | False | None | False | 23600.0 | 0 |
| 2940033 | 97113 | None | code76 | supplying and flush mounting powder coated galvanized metal bo suitable for mounting modular switch plates. The bo should be firmly flush mounted after due groove cutting in brick stone c.c wall (15 3.5) 4 5 way GOK SR for Electrical Works 2022 23. No.3.4.2 P.No.05 | Mtr | 138.0 | 138.0 | 8.0 | False | None | None | False | None | False | 1104.0 | 0 |
| 2940034 | 97113 | None | code77 | supplying and flush mounting powder coated galvanized metal bo suitable for mounting modular switch plates. The bo should be firmly flush mounted after due groove cutting in brick stone c.c wall (15 3.5) 8 way GOK SR for Electrical Works 2022 23. No.3.4.4 P.No.05 | Each | 250.0 | 250.0 | 14.0 | False | None | None | False | None | False | 3500.0 | 0 |
| 2940035 | 97113 | None | code78 | supplying and flush mounting powder coated galvanized metal bo suitable for mounting modular switch plates. The bo should be firmly flush mounted after due groove cutting in brick stone c.c wall (15 3.5) 10 12 way GOK SR for Electrical Works 2022 23. No.3.4.5 P.No.05 | Each | 325.0 | 325.0 | 6.0 | False | None | None | False | None | False | 1950.0 | 0 |
| 2940036 | 97113 | None | code79 | Supplying and fi ing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the e isting metal PVC bo . 4Module GOK SR for Electrical Works 2022 23. No.3.5.2 P.No.05 | Mtr | 175.0 | 175.0 | 8.0 | False | None | None | False | None | False | 1400.0 | 0 |
| 2940037 | 97113 | None | code80 | Supplying and fi ing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the e isting metal PVC bo . 8Module GOK SR for Electrical Works 2022 23. No.3.5.4 P.No.05 | Mtr | 302.0 | 302.0 | 15.0 | False | None | None | False | None | False | 4530.0 | 0 |
| 2940038 | 97113 | None | code81 | Supplying and fi ing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws bolts nuts etc. complete on the e isting metal PVC bo . 10 12Module GOK SR for Electrical Works 2022 23. No.3.5.5 P.No.05 | Mtr | 363.0 | 363.0 | 6.0 | False | None | None | False | None | False | 2178.0 | 0 |
| 2940039 | 97113 | None | code82 | Supplying and fi ing of modular switch and connected accessories on e isting modular switch plate as per IS 3854 and IS 1293 6Amps one way Switch GOK SR for Electrical Works 2022 23. No.3.6.1 P.No.05 | Each | 88.0 | 88.0 | 80.0 | False | None | None | False | None | False | 7040.0 | 0 |
| 2940040 | 97113 | None | code83 | Supplying and fi ing of modular switch and connected accessories on e isting modular switch plate as per IS 3854 and IS 1293 6A Two Way Switch GOK SR for Electrical Works 2022 23. No.3.6.2 P.No.05 | Each | 152.0 | 152.0 | 4.0 | False | None | None | False | None | False | 608.0 | 0 |
| 2940041 | 97113 | None | code84 | Supplying and fi ing superior quality of modular socket stepped electronic fan regulator dimmer telephone socket etc on e isting modular switch plate as per IS 1293.(16 3.7) Group A 6A Three Way socket GOK SR for Electrical Works 2022 23. No.3.6.3 P.No.05 | Each | 162.0 | 162.0 | 30.0 | False | None | None | False | None | False | 4860.0 | 0 |
| 2940042 | 97113 | None | code85 | Supplying and fi ing superior quality of modular socket stepped electronic fan regulator dimmer telephone socket etc on e isting modular switch plate as per IS 1293.(16 3.7) Stepped Fan Regulator Two Module GOK SR for Electrical Works 2022 23. No.3.6.4 P.No.05 | Each | 313.0 | 313.0 | 8.0 | False | None | None | False | None | False | 2504.0 | 0 |
| 2940043 | 97113 | None | code86 | Supplying and fi ing superior quality of modular socket stepped electronic fan regulator dimmer telephone socket etc on e isting modular switch plate as per IS 1293.(16 3.7) Group A 32Amps DP Switch GOK SR for Electrical Works 2022 23. No.3.6.10 P.No.05 | Each | 375.0 | 375.0 | 15.0 | False | None | None | False | None | False | 5625.0 | 0 |
| 2940044 | 97113 | None | code87 | Supplying and fi ing superior quality of modular socket stepped electronic fan regulator dimmer telephone socket etc on e isting modular switch plate as per IS 1293.(16 3.7) Group A 6 16A Universal Socket GOK SR for Electrical Works 2022 23. No.3.6.11 P.No.05 | Each | 249.0 | 249.0 | 15.0 | False | None | None | False | None | False | 3735.0 | 0 |
| 2940045 | 97113 | None | code88 | Supplying and fi ing superior quality of modular socket stepped electronic fan regulator dimmer telephone socket etc on e isting modular switch plate as per IS 1293.(16 3.7) Group A RJ45 I.O Outlet Cat 6 GOK SR for Electrical Works 2022 23. No.3.6.13 P.No.05 | Each | 211.0 | 211.0 | 15.0 | False | None | None | False | None | False | 3165.0 | 0 |
| 2940046 | 97113 | None | code89 | Supplying and fi ing replacing of 6 16 32Amps electrical accessories on e isting switch board. 6A Bakelite Ceiling Rose GOK SR for Electrical Works 2022 23. No.3.14.5 P.No.05 | No | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 |
| 2940047 | 97113 | None | code90 | Supplying and fi ing replacing of 6 16 32Amps electrical accessories on e isting switch board. 6Amps Lamp Holder GOK SR for Electrical Works 2022 23. No.3.14.6 P.No.05 | No | 63.0 | 63.0 | 15.0 | False | None | None | False | None | False | 945.0 | 0 |
| 2940048 | 97113 | None | code91 | Supplying and fi ing regular MCB distribution boards on wall wood board flush mounting using required clamps bolts nuts etc with provision for fi ing suitable type capacity MCB single phase 3 phase single door with powder coated painting made out of 14 SWG MS enclosure III. Double door 4 way TP and N GOK SR for Electrical Works 2022 23. No.5.18.11 P.No.13 | Each | 1928.0 | 1928.0 | 3.0 | False | None | None | False | None | False | 5784.0 | 0 |
| 2940049 | 97113 | None | code92 | Supplying and fi ing Miniature Circuit Breakers in e isting MCB distribution boards using necessary fi ing material and c type curve indicator ON OFF energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to IEC60898.(47 6.16) 6 32Amps TPN GOK SR for Electrical Works 2022 23. No.5.17.1 P.No.13 | Each | 523.0 | 523.0 | 5.0 | False | None | None | False | None | False | 2615.0 | 0 |
| 2940050 | 97113 | None | code93 | Supplying fi ing and wiring earth leakage Miniature Circuit Breaker(ELEMCB) 240 450V upto 300mA sensivity on e isting wood panel board (47 6.18) 32 40 Amps 4 pole GOK SR for Electrical Works 2022 23. No.5.20.3 P.No.13 | Each | 2826.0 | 2826.0 | 5.0 | False | None | None | False | None | False | 14130.0 | 0 |
| 2940051 | 97113 | None | code94 | Supplying capacitor type ceiling fan complete with down rod blades shackle canopies etc for operation on 230 V 50 cycles. Single phase AC supply conforming to ISS 374 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model GOK SR for Electrical Works 2022 23. No.6.3.1 P.No.22 | Each | 2085.0 | 2085.0 | 5.0 | False | None | None | False | None | False | 10425.0 | 0 |
| 2940052 | 97113 | None | code95 | Supplying ......TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 V with hermetically sealed compressor with air cooled condenser motor capacitor and start run capacitors relay and over load protector internal unit with one indoor and one outdoor unit The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded cordless) suitable capacity 3 core sheathed PVC copper cable and a battery operated wireless remote unit. 5Star 1 Ton Capacity GOK SR for Electrical Works 2022 23. No.6.7.1 P.No.23 | Each | 44570.0 | 44570.0 | 4.0 | False | None | None | False | None | False | 178280.0 | 0 |
| 2940053 | 97113 | None | code96 | Supplying and drawing UTP CAT 6E LAN cable. GOK SR for Electrical Works 2022 23. No.8.1 P.No.27 | Mtr | 34.0 | 34.0 | 300.0 | False | None | None | False | None | False | 10200.0 | 0 |
| 2940054 | 97113 | None | code97 | Supplying and Fi ing of switch mounting rack with power manager and Cable manager. 18U with 650mm depth GOK SR for Electrical Works 2022 23. No.8.4.5 P.No.28 | Each | 20411.0 | 20411.0 | 1.0 | False | None | None | False | None | False | 20411.0 | 0 |
| 2940055 | 97113 | None | code98 | Supplying fi ing of Network Switches 24 Port 10 100 Switch GOK SR for Electrical Works 2022 23. No.8.9.5 P.No.28 | Each | 5343.0 | 5343.0 | 2.0 | False | None | None | False | None | False | 10686.0 | 0 |
| 2940056 | 97113 | None | code99 | Switch Supplying and Fi ing of ... ms Cat 6 Patch Cable 2m GOK SR for Electrical Works 2022 23. No.8.11.2 P.No.28 | Each | 286.0 | 286.0 | 15.0 | False | None | None | False | None | False | 4290.0 | 0 |
| 2940057 | 97113 | None | code100 | Supplying erecting testing and commissioning of OFF LINE UPS system suitable for operation on 230V 50Hz A C supply with all accessories complete and E cluding batteries and wiring complete 5 kVA OFF LINE UPS GOK SR for Electrical Works 2022 23. No.9.2.5 P.No.29 | Each | 38661.0 | 38661.0 | 1.0 | False | None | None | False | None | False | 38661.0 | 0 |
| 2940058 | 97113 | None | code101 | Supplying installation testing and commissioning of 12V DC AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 80 AH batteries. GOK SR for Electrical Works 2022 23. No.9.5.6 P.No.29 | Each | 10748.0 | 10748.0 | 10.0 | False | None | None | False | None | False | 107480.0 | 0 |
| 2940059 | 97113 | None | code102 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast e truded aluminium housing with spring loaded false ceiling clA Power LEDs with CCT 6500 degree K CRI 70%. efficacy 100 lumen per W 120degree beam spread life 25000 burning hours and Compliance to IS 10322 IEC 60598 LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly. with PF 0.95 power loss should 5% of lamp Wage. short circuit and open circuit protection to be integrated in the circuit THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. GOK SR for Electrical Works 2022 23. No.11.6.2 P.No.35 | Nos | 5651.0 | 5651.0 | 20.0 | False | None | None | False | None | False | 113020.0 | 0 |
| 2940060 | 97113 | None | code103 | Supplying of recess mounting non integrated type LED down light. W luminaire comprising of pressure decast e truded aluminium housing with spring loaded false ceiling clA LED of Power COB with CCT 6500 degree K CRI 70%. efficacy 100 lumen per W 120degree beam spread life 25000 burning hours and Compliance to IS10322 IEC 60598 LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly. with PF 0.95 power loss should 5% of lamp Wage short circuit and open circuit protection to be integrated in the circuit THD less than 20% Life as per LM 79. The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10 12W GOK SR for Electrical Works 2022 23. No.11.4.2 P.No.34 | Each | 1478.0 | 1478.0 | 10.0 | False | None | None | False | None | False | 14780.0 | 0 |
| 2940061 | 97113 | None | code104 | Supplying And Fi ing Metal Fan Bo with Round Hook GOK SR for Electrical Works 2022 23. No.1.12 P.No.2 | Mtr | 163.0 | 163.0 | 8.0 | False | None | None | False | None | False | 1304.0 | 0 |
| 2940062 | 97113 | None | code105 | 4MP Progressive scan CMOS h.265 H.264and MJPEG dual stream encoding 20fps; 4MP(2688 1520) Integrated Wifi (802.11b g n) Support True Day Night (ICR); DWDR; BLC; 3DNR; AWB; AGC Privacy zones; Motion Detection Integrated IR LEDs; ma imum 30m illumination Multiple network monitoring Web viewer; CMS and Mobile 2.8mm Fi ed Lens ( 106 degree Angle of View) Make Dahua Rate is obtained from GEM Website.Product ID 5116877 20103019716 | Nos | 9500.0 | 9500.0 | 5.0 | False | None | None | False | None | False | 47500.0 | 0 |
| 2940063 | 97113 | None | code106 | 4CH NVR Cooper 1U H.265 Network Video Recorder H.265+ H.264+ codec decoding Ma 40 Mbps 20 Mbps incoming outgoing bandwidth Ma 4 8 channel IP camera inputs Internal HDD 1 SATA 3 Port up to 4TB capacity for each HDD GOK SR for Electrical Works 2022 23. No.1.12 P.No.2 | Nos | 9500.0 | 9500.0 | 2.0 | False | None | None | False | None | False | 19000.0 | 0 |
| 2940064 | 97113 | None | code107 | 1TB Hard disk for survilence Rate is obtained from GEM Website. | Nos | 3190.0 | 3190.0 | 1.0 | False | None | None | False | None | False | 3190.0 | 0 |
| 2940065 | 97113 | None | code108 | 4Port POE switch Make Cisco Rate is obtained from GEM Website.Product id 5116877 84368887951 | Nos | 17000.0 | 17000.0 | 1.0 | False | None | None | False | None | False | 17000.0 | 0 |
| 2940066 | 97113 | None | code109 | Supplying and drawing UTP CAT 6E LAN cable. GOK SR for Electrical Works 2022 23. No.8.1 P.No.27 | Mtr | 34.0 | 34.0 | 150.0 | False | None | None | False | None | False | 5100.0 | 0 |
| 2940067 | 97113 | None | code110 | Desktop Providing INTEL CORE I5 PROCESSOR 1OTHGEN 8GB RAM 1TB HDD WINDOWS 10 PRO KEYBOARD AND MOUSE web camera HP 21.5 LED MONITER 3 years Hardware and Software WARRANTY Required Rates are taken from Gem Website Product id 5116877 34571175282 | Each | 42448.0 | 42448.0 | 6.0 | False | None | None | False | None | False | 254688.0 | 0 |
| 2940068 | 97113 | None | code111 | HP MFP 2606 SDW Printer Printers p to 20 ppm (A4) Rmpv up to 250 to 2500 Pages 1200 * 1200 dpi memory 64 mb Duple with Wi Fi Printing 01 Toner Cartridge 3 years Hardware Warranty Rates are taken from Gem Website Product id 5116877 77326030306 | Each | 15500.0 | 15500.0 | 2.0 | False | None | None | False | None | False | 31000.0 | 0 |
| 2940069 | 97113 | None | code112 | Providing and Fi ing Verneer Paneling Over the 50mm 35mm sal wood frame work and top covered out of 4mm thick approved veneer fi ed over 12mm ply finished in melomine polish complete including cost and conveyance of all materials labour for all items of work HGM of equipment etc. complete as per specification.(Rate Per sq.Mtr)KSFIC 2020 21 KSFIC.T 68 | Sqm | 7380.0 | 7380.0 | 31.7519 | False | None | None | False | None | False | 234329.022 | 0 |
| 2940070 | 97113 | None | code113 | Office Table of size 4' 2.5'. Made out of 12 18mm MDF one key board and 3drawers on the right side. Table to be coveredwith 1mm laminate wherever visible. Hardware of the drawer should be telescopic channel SS handle with one lock. The table top should be made with 25mm MDF along with edge bending.KSFIC 2020 21 KSFIC.T 58 | Each | 19960.0 | 19960.0 | 5.0 | False | None | None | False | None | False | 99800.0 | 0 |
| 2940071 | 97113 | None | code114 | Office Table of size 6' 3'or 5' 3'. Made out of 18mm MDF one key board and 3drawers on the right side. Table to be coveredwith 1mm laminate wherever visible. Hardware of the drawer should be telescopic channel SS handle with one lock. The table top should be made with 25mm MDF along with edge bending.KSFIC 2020 21 KSFIC.T 56 | Each | 29900.0 | 29900.0 | 2.0 | False | None | None | False | None | False | 59800.0 | 0 |
| 2940072 | 97113 | None | code115 | Wooden Rack (Teak Wood) of size 6' 3' 1.5'. Made out of teak wood frame of section 2.25'' 2.25'' and supporting patties of thickness 3'' 1.25''. Panel to be made out of 12mm plywood with veneer on the outer side. 18mm plywood shelves will be provided inside.Entire rack to be polished outer side and painted inside. Front teak wood beading. Rack shall be neatly finished and polished.KSFIC 2020 21 KSFIC.T 70 | Each | 29640.0 | 29640.0 | 1.0 | False | None | None | False | None | False | 29640.0 | 0 |
| 2940073 | 97113 | None | code116 | Notice Board of size 4' 3' using 18mm plywood for body back 8mm plywood and 12mm soft board with cloth.And 5mm plain glass for door with lock and alluminium chanal with teak wood beading. Outerside laminated sheet or veneer with polish inner side paint or polish.KSFIC 2020 21 KSFIC.T 77 | Each | 13620.0 | 13620.0 | 1.0 | False | None | None | False | None | False | 13620.0 | 0 |
| 2940074 | 97113 | None | code117 | Teak Wood Bench With Back Size 182.88cm L 46cm W 96cm H Legs 4.4 4.44cm.Patties at top and bottom around 5.68 2.54cm in section and polished seat shall be provided with 18mm block board with laminated sheet on the top board. Back with Teak wood patti.KSFIC 2020 21 KSFIC.T 91 | Each | 25840.0 | 25840.0 | 1.0 | False | None | None | False | None | False | 25840.0 | 0 |
| 2940075 | 97113 | None | code118 | Computer Chair Stainless steel base ABS seat and back cushion with arm Hydraulic Height adjustment.KSFIC 2020 21 KSFIC.T 92 | Each | 5540.0 | 5540.0 | 12.0 | False | None | None | False | None | False | 66480.0 | 0 |
| 2940076 | 97113 | None | code119 | Director Cushion Chair High back chair with seat and back High quality feather touch Re ine. Arms with cushioning. Chair to have SS base with 5 Caster wheel legs along with Syncro Mechanisum. KSFIC 2020 21 KSFIC.T 94 | Each | 11280.0 | 11280.0 | 2.0 | False | None | None | False | None | False | 22560.0 | 0 |
| 2940077 | 97113 | None | code120 | Providing and fi ing Storage unit of 0.75m width made out of 19mm thick commercial ply vertical support finished in approved 1.5mm laminate with 12mm thick ply packing internally finished with enamel paint of approved colour and shade shelves shall be formed out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved shade and colour etc. complete the rate includes cost of all materials labour charges complete as per specification. (Rate Per Sq.Mtr)KSFIC 2020 21 KSFIC.T 102 | Sqm | 17620.0 | 17620.0 | 11.7749 | False | None | None | False | None | False | 207473.738 | 0 |