2861140 | 92976 | None | NSR-1 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In all kinds of soil upto 300 mm depth. Vol-1 Page No.5) Item No.1.1 PWD SR 2023-24 | Cum | 100.1 | 100.1 | 733.2 | False | None | None | False | None | False | 73393.32 | 0 |
2861141 | 92976 | None | NSR-2 | Demolishing cement concrete manually/ by mechanical means including
disposal of material to the appropriate disposal area as per direction of
Engineer-in-charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Vol -2 Page No.187 Item No.19.2.2 PWD SR 2023-24" | Cum | 1131.9 | 1131.9 | 450.0 | False | None | None | False | None | False | 509355.0 | 0 |
2861142 | 92976 | None | NSR-3 | Earth work excavation by manual means for drains, canals, waste weir, draft,
approach channels, key trenches, foundation of Buildings & bridges and such
simillar works in all kinds of soils, as per drawing and technical specifications,
including setting out, shoring, strutting, barricading, caution lights, removal
of stumps and other deleterious matter, excavated surface leveled and sides
neatly dressed disposing off the excavated stuff or sorting & stacking the
selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of
labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m. Vol -1 Page No.5 Item No.1.4.1 PWD SR 2023-24" | Cum | 266.2 | 266.2 | 328.19 | False | None | None | False | None | False | 87364.178 | 0 |
2861143 | 92976 | None | NSR-4 | Earth work excavation by manual means for drains,canals, waste weir draft,approach channels, key trench, foundation of Bridges and such similar works,as per drawing and technicalspecifications, including setting out, shoring,strutting, barricading, caution lights,excavated surface leveled and sides neatlydressed disposing off or leveling the excavatedstuff or sorting & stacking theselected stuff for reuse in a radius of 50 m and lift upto1.5 m including costof labour, tools, usage & other appurtenances required to complete the work.
In ordinary/soft rock without blasting upto 1.5 m depth. Vol -1 Page No.5 Item No.1.5.1 PWD SR 2023-24"
| Cum | 328.9 | 328.9 | 109.4 | False | None | None | False | None | False | 35981.66 | 0 |
2861144 | 92976 | None | NSR-5 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.
Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates. Vol -1 Page No.15 Item No.2.1.2 PWD SR 2023-24"
| Cum | 6230.4 | 6230.4 | 209.27 | False | None | None | False | None | False | 1303835.808 | 0 |
2861145 | 92976 | None | NSR-6 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.
Vol -1 Page No.15 Item No.2.2.1 PWD SR 2023-24"
| Cum | 7468.96 | 7468.96 | 104.59 | False | None | None | False | None | False | 781178.5264 | 0 |
2861146 | 92976 | None | NSR-7 | Providing and laying in Cement Concrete for all Basement & surface level
works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fine aggregates as per relevant
IS Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per
technical specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Vol -1 Page No.16 Item No.2.3.1 PWD SR 2023-24"
| Cum | 10432.95 | 10432.95 | 16.56 | False | None | None | False | None | False | 172769.652 | 0 |
2861147 | 92976 | None | NSR-8 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Vol -1 Page No.16 Item No.2.5.1 PWD SR 2023-24" | Cum | 12398.1 | 12398.1 | 8.42 | False | None | None | False | None | False | 104392.002 | 0 |
2861148 | 92976 | None | NSR-9 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Vol -1 Page No.16 Item No.2.5.1 PWD SR 2023-24"
| Cum | 11668.8 | 11668.8 | 20.07 | False | None | None | False | None | False | 234192.816 | 0 |
2861149 | 92976 | None | NSR-10 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Vol -1 Page No.16 Item No.2.5.1 PWD SR 2023-24"
| Cum | 10574.85 | 10574.85 | 2.7 | False | None | None | False | None | False | 28552.095 | 0 |
2861150 | 92976 | None | NSR-11 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Vol -1 Page No.16 Item No.2.5.1 PWD SR 2023-24"
| Cum | 7293.0 | 7293.0 | 164.81 | False | None | None | False | None | False | 1201959.33 | 0 |
2861151 | 92976 | None | NSR-12 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. Lift Above 3.5 m.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Vol -1 Page No.16 Item No.2.5.1 PWD SR 2023-24"
| Cum | 12522.08 | 12522.08 | 32.76 | False | None | None | False | None | False | 410223.3408 | 0 |
2861152 | 92976 | None | NSR-13 | Providing Size Stone masonry with hard stone in foundation & plinth with
Cement mortar 1:6 (1 cement : 6 coarse sand) Vol -2 Page No.9 Item No.5.4 PWD SR 2023-24"
| Cum | 7027.9 | 7027.9 | 98.59 | False | None | None | False | None | False | 692880.661 | 0 |
2861153 | 92976 | None | NSR-14 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of
foundations and other similar works etc. in layers not exceeding 20cm in depth,
consolidating each deposited layer by ramming and watering, lead up to 50 m
and lift upto 1.5 m. No. KBS Vol -1 Page No.7 Item No.1.9 PWD SR 2023-24"
| Cum | 292.6 | 292.6 | 702.11 | False | None | None | False | None | False | 205437.386 | 0 |
2861154 | 92976 | None | NSR-15 | Construction of Embankment by excavating the available approved Gravel/
Murrum deposited at a place or borrow pits during or prior excavation with all
lifts and lead, transportation to site, spreading, grading to required slope and
compacting to meet the requirement complete as per specifications, including
cost of labour,rolling,water,all materials,usage& all other appurtenaces required
to complete the work. Vol -1 Page No.7 Item No.1.8 PWD SR 2023-24"
| Cum | 521.4 | 521.4 | 667.66 | False | None | None | False | None | False | 348117.924 | 0 |
2861155 | 92976 | None | NSR-16 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x200x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications.
Vol -2 Page No.17 Item No.6.32 PWD SR 2023-24" | Sqm | 1441.0 | 1441.0 | 273.18 | False | None | None | False | None | False | 393652.38 | 0 |
2861156 | 92976 | None | NSR-17 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. Vol -2 Page No.42 Item No.8.8 PWD SR 2023-24"
| Sqm | 408.1 | 408.1 | 416.38 | False | None | None | False | None | False | 169924.678 | 0 |
2861157 | 92976 | None | NSR-18 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished
with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1
cement : 6 fine sand) to brick masonry including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. Vol -2 Page No.42 Item No.8.8 PWD SR 2023-24"
| Sqm | 408.1 | 408.1 | 367.38 | False | None | None | False | None | False | 149927.778 | 0 |
2861158 | 92976 | None | NSR-19 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol -2 Page No.45 Item No.8.25 PWD SR 2023-24"
| Sqm | 150.7 | 150.7 | 416.38 | False | None | None | False | None | False | 62748.466 | 0 |
2861159 | 92976 | None | NSR-20 | Distempering with dry distemper of approved brand and manufacture
(two coats) of required shade on new work, over and including water
thinnable priming coat to give an even shade after thoroughly brooming
the surface to remove all dirt, dust, mortar drops and foreign matter
including preparing the surface even and sand paper smooth, cost of
materials, labour complete as per specifications and as per directions of
Engineer-in-charge. Vol -2 Page No.45 Item No.8.24 PWD SR 2023-24"
| Sqm | 118.8 | 118.8 | 367.38 | False | None | None | False | None | False | 43644.744 | 0 |
2861160 | 92976 | None | NSR-21 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to
brick/stone masonry including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of
materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Vol -2 Page No.41 Item No.8.3.1 PWD SR 2023-24"
| Sqm | 389.4 | 389.4 | 32.4 | False | None | None | False | None | False | 12616.56 | 0 |
2861161 | 92976 | None | NSR-22 | Providing and fixing of 2-track x 2-panel sliding windows made out of multi
chambered UPVC (Matching to RAL-9016) sections and with minimum
TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and
lead free, gaskets -grey colour having isolated drainage and reinforced with
Galvanized Iron profile through-out the window frame. The outer frame
having an overall size of 50mm width x 42mmheight with reinforcement
of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi
reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded
Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows
shall be provided with 5mm plain float glass, standard hardware and single
point locking system with touch lock. Wall thickness of frame sash shall
be of 1.8+-0.2 mm. Maximum possible size -1519mm x 1519mm. (The
cost is inclusive of all fixtures and separate charges for minor T and P's shall not be made) Vol -2 Page No.109 Item No.12.86 PWD SR 2023-24 | Sqm | 5929.0 | 5929.0 | 40.5 | False | None | None | False | None | False | 240124.5 | 0 |
2861162 | 92976 | None | NSR-23 | Supplying and fixing rolling shutters of approved make, made of required
size M.S. laths, interlocked together through their entire length and
jointed together at the end by end locks, mounted on specially
designed pipe shaft with brackets, side guides and arrangements for
inside and outside locking with push and pull operation complete,
including the cost of providing and fixing necessary 27.5 cm long wire
springs manufactured from high tensile steel wire of adequate strength
conforming to IS: 4454 - part 1 and M.S. top cover of required thickness
for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. Vol -2 Page No.78 Item No.11.6.1 PWD SR 2023-24"
| Sqm | 2896.3 | 2896.3 | 95.09 | False | None | None | False | None | False | 275409.167 | 0 |
2861163 | 92976 | None | NSR-24 | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to steel windows by welding Vol -2 Page No.86 Item No.11.34A PWD SR 2023-24"
| Kg | 184.8 | 184.8 | 850.5 | False | None | None | False | None | False | 157172.4 | 0 |
2861164 | 92976 | None | NSR-25 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and
should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required. Vol -2 Page No.26 Item No.7.38 PWD SR 2023-24"
| Sqm | 624.8 | 624.8 | 1770.0 | False | None | None | False | None | False | 1105896.0 | 0 |
2861165 | 92976 | None | NSR-26 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Gutter (600 mm over all girth) Vol -2 Page No.26 Item No.7.39.6 PWD SR 2023-24
| Rmtr | 1181.4 | 1181.4 | 90.0 | False | None | None | False | None | False | 106326.0 | 0 |
2861166 | 92976 | None | NSR-27 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) Vol -2 Page No.26 Item No.7.39.1 PWD SR 2023-24
| Rmtr | 496.1 | 496.1 | 45.0 | False | None | None | False | None | False | 22324.5 | 0 |
2861167 | 92976 | None | NSR-28 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter Vol -2 Page No.125 Item No.13.48 PWD SR 2023-24
| Rmtr | 320.1 | 320.1 | 128.0 | False | None | None | False | None | False | 40972.8 | 0 |
2861168 | 92976 | None | NSR-29 | Providing and fixing Structural Steel work riveted, bolted or welded in
built up sections, trusses and framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer all
complete including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-inCharge. Vol -2 Page No.77 Item No.11.2 PWD SR 2023-24"
| Kgs | 124.3 | 124.3 | 43200.0 | False | None | None | False | None | False | 5369760.0 | 0 |
2861169 | 92976 | None | NSR-30 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work ready to use "cut and bend" rebars of approved make from factory/workshop to construction site including placing in position, binding and anchoring to adjacent members wher eever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications Vol -2 Page No.84 Item No.11.33 PWD SR 2023-24
| Kgs | 94.6 | 94.6 | 24000.0 | False | None | None | False | None | False | 2270400.0 | 0 |
2861170 | 92976 | None | NSR-31 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener opping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 L per 50 kg of cement or as per direction of Engineer incharge. Vol -2 Page No.59 Item No.9.2 PWD SR 2023-24
| Sqm | 880.0 | 880.0 | 1080.0 | False | None | None | False | None | False | 950400.0 | 0 |
2861171 | 92976 | None | NSR-32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Vol -2 Page No.48 Item No.8.4 PWD SR 2023-24"
| Sqm | 126.5 | 126.5 | 668.8 | False | None | None | False | None | False | 84603.2 | 0 |
2861172 | 92976 | None | NSR-33 | Supplying and erecting of 24” dia wind driven turbine ventilators with the following technical specifications over the Galvalume sheet roofing including cutting open the roof, leak proofing the joints and also including the cost of all materials, transportation charges, taxes etc., complete as per the directions of the engineer in charge of the work.
Technical specifications:
Material Aluminum except for center shaft which shall be of stainless steel
Vanes 38 Nos of 0.5 mm thickness
Bearing ISI approved
Rivets Aluminium pneumatic
Turbine doom thickness 1.2 mm
Turbine outer dia 680 mm
Turbine doom dia 372 mm
Turbine rotor dia 650 mm
Turbine throat dia 610 mm
Turbine height 350 mm "
| Nos | 7920.0 | 7920.0 | 12.0 | False | None | None | False | None | False | 95040.0 | 0 |
2861173 | 92976 | None | NSR-34 | Providing and fixing gears for operating rolling shutters
| Nos | 16500.0 | 16500.0 | 6.0 | False | None | None | False | None | False | 99000.0 | 0 |
2861174 | 92976 | None | NSR-35 | Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.s
| Mtr | 80.0 | 80.0 | 580.0 | False | None | None | False | None | False | 46400.0 | 0 |
2861175 | 92976 | None | NSR-36 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit CC floor with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Mtr | 62.0 | 62.0 | 300.0 | False | None | None | False | None | False | 18600.0 | 0 |
2861176 | 92976 | None | NSR-37 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch
| Point | 386.0 | 386.0 | 48.0 | False | None | None | False | None | False | 18528.0 | 0 |
2861177 | 92976 | None | NSR-38 | Long point above 6m upto 10m from tapping point to out let via switch
| Point | 567.0 | 567.0 | 28.0 | False | None | None | False | None | False | 15876.0 | 0 |
2861178 | 92976 | None | NSR-39 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2
| Mtr | 26.0 | 26.0 | 2200.0 | False | None | None | False | None | False | 57200.0 | 0 |
2861179 | 92976 | None | NSR-40 | 2.5 sq mm DB to switch boards /MH lamps | Mtr | 40.0 | 40.0 | 1150.0 | False | None | None | False | None | False | 46000.0 | 0 |
2861180 | 92976 | None | NSR-41 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Mtr | 59.0 | 59.0 | 600.0 | False | None | None | False | None | False | 35400.0 | 0 |
2861181 | 92976 | None | NSR-42 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.6 sqmm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Mtr | 87.0 | 87.0 | 450.0 | False | None | None | False | None | False | 39150.0 | 0 |
2861182 | 92976 | None | NSR-43 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.
| Each | 88.0 | 88.0 | 40.0 | False | None | None | False | None | False | 3520.0 | 0 |
2861183 | 92976 | None | NSR-44 | 6/16 Amps universal socket
| Each | 249.0 | 249.0 | 18.0 | False | None | None | False | None | False | 4482.0 | 0 |
2861184 | 92976 | None | NSR-45 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete
| Each | 138.0 | 138.0 | 15.0 | False | None | None | False | None | False | 2070.0 | 0 |
2861185 | 92976 | None | NSR-46 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete
| Each | 175.0 | 175.0 | 15.0 | False | None | None | False | None | False | 2625.0 | 0 |
2861186 | 92976 | None | NSR-47 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 523.0 | 523.0 | 2.0 | False | None | None | False | None | False | 1046.0 | 0 |
2861187 | 92976 | None | NSR-48 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 A DP. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 |
2861188 | 92976 | None | NSR-49 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door.8 Way SP & N with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 1695.0 | 1695.0 | 1.0 | False | None | None | False | None | False | 1695.0 | 0 |
2861189 | 92976 | None | NSR-50 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.16A-25A 2 pole with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 4548.0 | 4548.0 | 1.0 | False | None | None | False | None | False | 4548.0 | 0 |
2861190 | 92976 | None | NSR-51 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. .16Amps with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 125.0 | 125.0 | 4.0 | False | None | None | False | None | False | 500.0 | 0 |
2861191 | 92976 | None | NSR-52 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single phase Class-1 Accuracy with Temper Proof Energy Meter with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 1242.0 | 1242.0 | 1.0 | False | None | None | False | None | False | 1242.0 | 0 |
2861192 | 92976 | None | NSR-53 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300mmx300mmx214mm with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 4054.0 | 4054.0 | 1.0 | False | None | None | False | None | False | 4054.0 | 0 |
2861193 | 92976 | None | NSR-54 | Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRI grater than 70%. efficacy grater than 100 lumen per W, 120degree beam spread, life grater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF grater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2'x2' /1'x4' 34-36 W
| Each | 6700.0 | 6700.0 | 14.0 | False | None | None | False | None | False | 93800.0 | 0 |
2861194 | 92976 | None | NSR-55 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body
part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 120 W Electrical SR 2022-23 (P.No-35, I.No-11.8.4) "
| Each | 11997.0 | 11997.0 | 14.0 | False | None | None | False | None | False | 167958.0 | 0 |
2861195 | 92976 | None | NSR-56 | Supplying and fixing angle iron frame work fabricated out of ms Angle iron and ms Flats with bolts washers etc and painted 2 coats of red oxide and then two coats approved paint etc Complete 50 x 50 x 6 mm
| Each | 356.0 | 356.0 | 14.0 | False | None | None | False | None | False | 4984.0 | 0 |
2861196 | 92976 | None | NSR-57 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 119.0 | 119.0 | 14.0 | False | None | None | False | None | False | 1666.0 | 0 |
2861197 | 92976 | None | NSR-58 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. with all leads & lifts complete as per specification and as directed by the Engineer incharge of the work.
| Each | 189.0 | 189.0 | 14.0 | False | None | None | False | None | False | 2646.0 | 0 |
2861198 | 92976 | None | NSR-59 | Supplying & fixing - flexible LED Strip Light . W Power consumption in 5 ms length CCT6500 degree K, CRI greater than 70%.efficacy greater than 80 lumen per W, life greater than 25000 burning hours andCompliance to IS 10322/IEC 60598, LM 79 & LM 80. TheLED are driven by HF electronic driver non integrated, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit &open circuit protection to be integrated in the circuit, THD lessthan 20%, Life as per LM 79. The operating input voltage shouldbe between 130 to 275 V. BIS Approved with 2 years Warrantyagainst any manufacturing defect working under standard electrical condition | Each | 1787.0 | 1787.0 | 3.0 | False | None | None | False | None | False | 5361.0 | 0 |
2861199 | 92976 | None | NSR-60 | Supplying and fixing 12 way TP & N double door regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts with provision for fixing suitable type capacity MCBs single phase/3 phase/ single door with power coated painting made out of 14 SWG MS enclosure for
| Each | 5744.0 | 5744.0 | 2.0 | False | None | None | False | None | False | 11488.0 | 0 |
2861200 | 92976 | None | NSR-61 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. Electrical SR 2022-23 6-32 A SP
| Each | 523.0 | 523.0 | 10.0 | False | None | None | False | None | False | 5230.0 | 0 |
2861201 | 92976 | None | NSR-62 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia, 2.9 mm thick, 2.5 meter long GI Pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed m.a. CC chamber of 400 x 400 x 400 mm with a cast iron cover, the earth electrode shall have staggered holes of 12mm dia and the electrodes should be covered from 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber, the connection from the electrode is to be established through GI strip using GI bolts and Nuts. (P.No-55 I no 7.2) For MCB D Board"
| Each | 4317.0 | 4317.0 | 2.0 | False | None | None | False | None | False | 8634.0 | 0 |
2861202 | 92976 | None | NSR-063 | Supplying of 1.1 KV LT UG cable having aluminium conductor PVC insulated. Extured inner sheathed, galvanized, steel strip (except 2cx10s.mm wire armoured) confirming to IS-3975:1990(No. of Strip indicated in GTP) & extureded PVC outer sheathed armoured cable with specified IS-154 Part-1:1988 & confirming to FTP of 10 Sqmm,25 Sqmm, 3.5 Core, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) Electrical SR 2022-23 (P.No-9, I.No-32.07
| Rmtr | 515.0 | 515.0 | 80.0 | False | None | None | False | None | False | 41200.0 | 0 |
2861203 | 92976 | None | NSR-64 | Labour charges for laying of earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. Electrical SR 2022-23 (P.No-8, I.No-5.17.1)
| Rmtr | 260.0 | 260.0 | 80.0 | False | None | None | False | None | False | 20800.0 | 0 |
2861204 | 92976 | None | NSR-65 | Supplying and fixing of class A (medium duty) 65mm GI pipe of wall thickness not less than 3.25 mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1. KV class
| Rmtr | 547.0 | 547.0 | 6.0 | False | None | None | False | None | False | 3282.0 | 0 |
2861205 | 92976 | None | NSR-66 | supplying amps ratred 3 Phasewith natural bus bar using required capacity electolytic aluminium strips covered with head shrinkable colored PVC Sleeve mounted of Phonemic /FRP/DMC insulator which are mounted on power coated 40 x60 MS flats frame work in existintg panel board the bus bar shall have cables as per IS specification with necessary bolts nuts and washers etc., complete (250 A 4 x 30 x 10 mm Aluminium Strip
| Mtr | 3078.0 | 3078.0 | 2.0 | False | None | None | False | None | False | 6156.0 | 0 |