1709202241000 | 0 | None | None | Other Works | Construction of new shed for electric panel near ETP plant in KSDL, Bengaluru | 915087.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2860967 | 92955 | None | NSR-1 | Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. SR 2023-24,V-1(P.No. 5, I.No. 1.2) | Cum | 632.5 | 632.5 | 14.33 | False | None | None | False | None | False | 9063.725 | 0 | 2860968 | 92955 | None | NSR-2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,
well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregatesSR 2023-24,V-1(P.No. 15, I.No. 2.1.2) " | Cum | 6230.4 | 6230.4 | 8.19 | False | None | None | False | None | False | 51026.976 | 0 | 2860969 | 92955 | None | NSR-3 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand)SR 2023-24,V-2(P.No. 9, I.No. 5.1.1)
| Cum | 6172.1 | 6172.1 | 8.45 | False | None | None | False | None | False | 52154.245 | 0 | 2860970 | 92955 | None | NSR-4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(V2 of SR 2023-24 P.No. 09, I.No.5.4) | Cum | 7027.9 | 7027.9 | 8.59 | False | None | None | False | None | False | 60369.661 | 0 | 2860971 | 92955 | None | NSR-5 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(V1 of SR 2023-24 P.No. 07, I.No.1.11)
| Cum | 476.3 | 476.3 | 28.7 | False | None | None | False | None | False | 13669.81 | 0 | 2860972 | 92955 | None | NSR-6 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm and down size graded crushed coarse aggregates SR 2023-24,V-1(P.No. 15, I.No. 2.1.4) | Cum | 6838.7 | 6838.7 | 7.65 | False | None | None | False | None | False | 52316.055 | 0 | 2860973 | 92955 | None | NSR-7 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.V1 of SR 2023-24(P.No. 18 I.No.2.11)
| Tonne | 98402.7 | 98402.7 | 0.763 | False | None | None | False | None | False | 75081.2601 | 0 | 2860974 | 92955 | None | NSR-8 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.SR 2023-24,V-2(Item No.6.32, P No.17)
| Sqm | 1441.0 | 1441.0 | 112.8 | False | None | None | False | None | False | 162544.8 | 0 | 2860975 | 92955 | None | NSR-9 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 500x500 mm.SR 2023-24,V-2(Item No.9.12.1, P No.60)
| Sqm | 1190.2 | 1190.2 | 47.84 | False | None | None | False | None | False | 56939.168 | 0 | 2860976 | 92955 | None | NSR-10 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Vol -2 Page No.42 Item No.8.8 PWD SR 2023-24
| Sqm | 408.1 | 408.1 | 217.72 | False | None | None | False | None | False | 88851.532 | 0 | 2860977 | 92955 | None | NSR-11 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) SR 2023-24,V-2(Item No.12.84, P No.108) | Sqm | 5525.3 | 5525.3 | 18.0 | False | None | None | False | None | False | 99455.4 | 0 | 2860978 | 92955 | None | NSR-12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.PWD SR 2023-24,V-2(P.No. 50, I.No.8.51)
| Sqm | 110.0 | 110.0 | 136.92 | False | None | None | False | None | False | 15061.2 | 0 | 2860979 | 92955 | None | NSR-13 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. PWD (SR 2023-24,V-2P.No. 51, I.No.8.55.2)
| Sqm | 58.3 | 58.3 | 217.72 | False | None | None | False | None | False | 12693.076 | 0 | 2860980 | 92955 | None | NSR-14 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. (SR 2023-24,V-2P. No. 50, I.No. 8.53.2)
| Sqm | 108.9 | 108.9 | 136.92 | False | None | None | False | None | False | 14910.588 | 0 | 2860981 | 92955 | None | NSR-15 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.PWD SR 2023-24,V-2(P.No. 46, I.No.8.30)
| Sqm | 191.4 | 191.4 | 80.8 | False | None | None | False | None | False | 15465.12 | 0 | 2860982 | 92955 | None | NSR-16 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.(SR 2023-24,V-2 P.No. 77, I.No. 11.2)
| Kgs | 124.3 | 124.3 | 247.65 | False | None | None | False | None | False | 30782.895 | 0 | 2860983 | 92955 | None | NSR-17 | Providing and laying in position Cement Concrete for all Foundation works. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesPWD SR 2023-24,V-1(P.No. 15, I.No. 2.2.1)
| Cum | 10373.55 | 10373.55 | 9.7 | False | None | None | False | None | False | 100623.435 | 0 | 2860984 | 92955 | None | NSR-18 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 160mm dia., 6 kg/sqcm & class 3 BWSSB-2023-24(P.No. 113, I.No. 10.1.9)
| Mtr | 679.8 | 679.8 | 6.0 | False | None | None | False | None | False | 4078.8 | 0 |
|