| 1709550912000 | 0 | None | None | Electrical | Electrification for Ward No. 08 Construction of lighting system for railway underpass of Huchcharaya Colony | 420296.52 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 2907247 | 95472 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m | m | 107.1 | 107.1 | 2.592 | False | None | None | False | None | False | 277.6032 | 0 | | 2907248 | 95472 | None | 1.17.1 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out,construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m | m | 275.1 | 275.1 | 36.0 | False | None | None | False | None | False | 9903.6 | 0 | | 2907249 | 95472 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | m | 5947.2 | 5947.2 | 0.216 | False | None | None | False | None | False | 1284.5952 | 0 | | 2907250 | 95472 | None | 2.12 | Supplying, fitting and placing Mild Steel Reinforcement complete as per drawing and technical specification. | Tonne | 77398.65 | 77398.65 | 0.12 | False | None | None | False | None | False | 9287.838 | 0 | | 2907251 | 95472 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | m | 6601.35 | 6601.35 | 2.592 | False | None | None | False | None | False | 17110.6992 | 0 | | 2907252 | 95472 | None | 66.4 | HDPE/PLB Pipe 50/42 mm | Km | 85014.0 | 85014.0 | 0.12 | False | None | None | False | None | False | 10201.68 | 0 | | 2907253 | 95472 | None | 32.03 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm) | Km | 118004.0 | 118004.0 | 0.25 | False | None | None | False | None | False | 29501.0 | 0 | | 2907254 | 95472 | None | 21.05 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff,2.5 to 25 Sqmm | Km | 20886.0 | 20886.0 | 0.25 | False | None | None | False | None | False | 5221.5 | 0 | | 2907255 | 95472 | None | MoRTH 602.6.3 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by
Engineer incharge | m | 70.0 | 70.0 | 25.0 | False | None | None | False | None | False | 1750.0 | 0 | | 2907256 | 95472 | None | 12.60.1 | Supplying & Fixing Chemical earthling for grounding. Conduits, IC cut-outs & other equipments backfill compound which is non- corrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance & capable of achieving ohmic value less than one ohm.Using 4ft. Copper bonded rod with backfill compound | 1 Kit | 4528.0 | 4528.0 | 6.0 | False | None | None | False | None | False | 27168.0 | 0 | | 2907257 | 95472 | None | 4.2.5 | Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards,Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom ….mm, top….mm with 3mm thick, suitable base plate and 4Nos of . long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.7 m - Top 70 mm and Bottom 130 mm dia | Each | 13500.0 | 13500.0 | 3.0 | False | None | None | False | None | False | 40500.0 | 0 | | 2907258 | 95472 | None | 4.2.6 | Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards,Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/sec for …….Mtrs pole in single section and single joint welded as per IS 9595/IS 10178AWS having dimensions bottom ….mm, top….mm with 3mm thick, suitable base plate and 4Nos of . long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.9 m - Top 70 mm and Bottom 155 mm dia KPWD Comman SR 2023-24 Item No: 4.2.7 | Each | 19500.0 | 19500.0 | 3.0 | False | None | None | False | None | False | 58500.0 | 0 | | 2907259 | 95472 | None | 11.9.4 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer Dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322 IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System. Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI & any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer Cree Nichia Lumileds Osram make LED Source.LED Floodlight 150W | Each | 12490.0 | 12490.0 | 10.0 | False | None | None | False | None | False | 124900.0 | 0 | | 2907260 | 95472 | None | 4.7.3 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., completeSingle Arm Bracket with 1000 mm Standard 40/50 mm dia | Each | 1544.0 | 1544.0 | 14.0 | False | None | None | False | None | False | 21616.0 | 0 | | 2907261 | 95472 | None | 2.5.2 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 .3C X 1.5Sq.mm | Mtr | 69.0 | 69.0 | 72.0 | False | None | None | False | None | False | 4968.0 | 0 | | 2907262 | 95472 | None | 11.8.4 | Supply of LED Streetlight luminaire with pressure die cast
aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect,LED Streetlight 90 W | Each | 7777.0 | 7777.0 | 4.0 | False | None | None | False | None | False | 31108.0 | 0 | | 2907263 | 95472 | None | 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Nos | 189.0 | 189.0 | 14.0 | False | None | None | False | None | False | 2646.0 | 0 | | 2907264 | 95472 | None | 5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32Amps | Nos | 200.0 | 200.0 | 3.0 | False | None | None | False | None | False | 600.0 | 0 | | 2907265 | 95472 | None | 11.15 | Supplying and fixing of LED Bulkhead of 10W with IP65 protection.and IK 08 impact resistance suitable for surface and wall mounting applications. | Each | 842.0 | 842.0 | 6.0 | False | None | None | False | None | False | 5052.0 | 0 | | 2907266 | 95472 | None | 1.1.1 | Supplying heavy gauge PVC conduit pipe . dia mm
thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick | Mtr | 68.0 | 68.0 | 90.0 | False | None | None | False | None | False | 6120.0 | 0 | | 2907267 | 95472 | None | 1.9.1 | Supplying PVC/GI flexible conduit pipe mm dia fixing on
surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely,20 mm | Mtr | 25.0 | 25.0 | 40.0 | False | None | None | False | None | False | 1000.0 | 0 | | 2907268 | 95472 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 mm2 | Mtr | 26.0 | 26.0 | 180.0 | False | None | None | False | None | False | 4680.0 | 0 | | 2907269 | 95472 | None | 5.43.1 | Supply and Installation / Fixing / Provision of Pole box with HRC Fuse / MCB provision and suitable connector / terminal for 3 Ph/ 1 Ph connections with Loop-In & Loop- Out terminals for 10 mm2 /25 mm2 3.5 C AI/Ar/Cu/Ar Cable and branch out 2.5 mm2 2 core AI/Cu PVC Insulated cable, enclosed in a Thermoplastic, Polystyrene enclosure, which should be shock proof, safe, IP65(Weather Proof), rust proof, dust proof, water proof having Internally Embedded Gasket with provision for cable entry through IP65 Thermoplastic,. Polyamide glands and/or grommets.200 mm x 200 mm x 98 mm | Each | 2300.0 | 2300.0 | 3.0 | False | None | None | False | None | False | 6900.0 | 0 |
|