1709361094000 | 0 | None | None | Buildings | Compound wall | 1870010.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2881448 | 94214 | None | PWD Uni SR 23-24 Vol-1 Item no. 1.15.1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 123.48 | False | None | None | False | None | False | 47064.402 | 0 | 2881449 | 94214 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.1.2 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 11.07 | False | None | None | False | None | False | 65835.504 | 0 | 2881450 | 94214 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6924.75 | 6924.75 | 28.8 | False | None | None | False | None | False | 199432.8 | 0 | 2881451 | 94214 | None | 2.2.1 | Centering & Shuttering charges for footing | Cum | 207.74 | 207.74 | 28.8 | False | None | None | False | None | False | 5982.912 | 0 | 2881452 | 94214 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 18.56 | False | None | None | False | None | False | 129205.44 | 0 | 2881453 | 94214 | None | 2.5.1 | Centering & Shuttering charges for Columns | Cum | 4873.05 | 4873.05 | 9.96 | False | None | None | False | None | False | 48535.578 | 0 | 2881454 | 94214 | None | 2.5.1 | Centering & Shuttering charges for Plinth beam | Cum | 3480.75 | 3480.75 | 8.9 | False | None | None | False | None | False | 30978.675 | 0 | 2881455 | 94214 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.11(a) | Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
a. Buildings | Tonne | 93929.85 | 93929.85 | 4.0 | False | None | None | False | None | False | 375719.4 | 0 | 2881456 | 94214 | None | PWD Uni SR 23-24 Vol-2 Item no. 6.8 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 66.65 | False | None | None | False | None | False | 557690.5425 | 0 | 2881457 | 94214 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 3.17 | False | None | None | False | None | False | 19934.3865 | 0 | 2881458 | 94214 | None | PWD Uni SR 23-24 Vol-2 Item no. 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick
wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge | Sqm | 309.75 | 309.75 | 588.0 | False | None | None | False | None | False | 182133.0 | 0 | 2881459 | 94214 | None | PWD Uni SR 23-24 Vol-2 Item no. 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 588.0 | False | None | None | False | None | False | 107427.6 | 0 | 2881460 | 94214 | None | PWD Uni SR 23-24 Vol-2 Item no. 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or
rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer,
including welding and bolted with special shaped washers etc. complete.
Hot finished seamless type tubes including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Sqm | 154.35 | 154.35 | 621.6 | False | None | None | False | None | False | 95943.96 | 0 | 2881461 | 94214 | None | PWD Uni SR 23-24 Vol-2 Item no. 8.37 | Painting on G.S. sheet with synthetic enamel paint of approved brand
and manufacture of required colour to give an even shade :New work (two
coats) including a coat of approved steel primer but excluding a coat of
mordant solution including preparing the surface after thorougly cleaning
oil, grease, dirt and foreign matter, cost of materials, labour complete as
per specifications and as per directions of Engineer-in-charge. | Sqm | 137.55 | 137.55 | 30.0 | False | None | None | False | None | False | 4126.5 | 0 |
| 1709361094000 | 0 | None | None | Buildings | Septic Tank | 150775.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2881462 | 94215 | None | PWD Uni SR 23-24 Vol-1 Item no. | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 28.35 | False | None | None | False | None | False | 10805.6025 | 0 | 2881463 | 94215 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.1.2 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 2.02 | False | None | None | False | None | False | 12013.344 | 0 | 2881464 | 94215 | None | PWD Uni SR 23-24 Vol-2 Item no. 6.8 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 8.31 | False | None | None | False | None | False | 69533.5095 | 0 | 2881465 | 94215 | None | PWD Uni SR 23-24 Vol-2 Item no. 8.6.2 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement to brick/
stone masonry including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per directions of
Engineer-in-charge. | Sqm | 450.45 | 450.45 | 65.5 | False | None | None | False | None | False | 29504.475 | 0 | 2881466 | 94215 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 1.6 | False | None | None | False | None | False | 11138.4 | 0 | 2881467 | 94215 | None | 2.5.1 | Centering & Shuttering charges for Roof Slab | Cum | 3480.75 | 3480.75 | 1.6 | False | None | None | False | None | False | 5569.2 | 0 | 2881468 | 94215 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.11(a) | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. Buildings | Tonne | 93929.85 | 93929.85 | 0.13 | False | None | None | False | None | False | 12210.8805 | 0 |
| 1709361094000 | 1 | None | None | Buildings | Building (New & Old) | 4549579.31 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2881469 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 19.22.2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction
of Engineer-in-charge.
For thickness of tiles 25 mm to 40 mm | Sqm | 77.7 | 77.7 | 649.83 | False | None | None | False | None | False | 50491.791 | 0 | 2881470 | 94216 | None | PWD Uni SR 23-24 Vol-1 Item no. 2.1.3 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 64.7 | False | None | None | False | None | False | 406862.715 | 0 | 2881471 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 9.35 | Flooring with 25mm thick polished shahabad slabs using cement mortar
1:6, 25mm thick over existing cement concrete bed or top of roof laid to
line and level and jointed with cement slurry mixed with pigment to match
the shade of the slab, , including cost of materials, labour, curing, polishing
complete as per specifications. | Sqm | 1717.8 | 1717.8 | 495.11 | False | None | None | False | None | False | 850499.958 | 0 | 2881472 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm
(thickness to be specified by the manufacturer) of 1st quality conforming
to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume
Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse
sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing
the joints with white cement and matching pigment etc., complete. | Sqm | 1129.8 | 1129.8 | 71.63 | False | None | None | False | None | False | 80927.574 | 0 | 2881473 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm
thick on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over existing rough plaster surface using glazed tiles of approved
make and size including cost of materials, labour, complete as per
specifications. | Sqm | 1521.45 | 1521.45 | 113.4 | False | None | None | False | None | False | 172532.43 | 0 | 2881474 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 11.3 | Providing and fixing in position collapsible steel shutters with vertical
channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size,
with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia
steel pulleys, complete with bolts, nuts, locking arrangement, stoppers,
handles, including applying a priming coat of approved steel primer
including cost of materials ,labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge.
| Sqm | 8689.8 | 8689.8 | 5.04 | False | None | None | False | None | False | 43796.592 | 0 | 2881475 | 94216 | None | PWD Uni SR 23-24 Vol-1 Item no. 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 103755.75 | 103755.75 | 0.67 | False | None | None | False | None | False | 69516.3525 | 0 | 2881476 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 12.51 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications. | No | 1066.8 | 1066.8 | 14.0 | False | None | None | False | None | False | 14935.2 | 0 | 2881477 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters
for doors with , stiles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete
as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 23.94 | False | None | None | False | None | False | 144336.654 | 0 | 2881478 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with
a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam
sheet metered cut at corners & jointed 2 No.s of 150mm long brackets
of 15x15mm M.S Square tube, the entire door frame to be reinforced with
19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the
wall using M.S. Screws of 65/80mm size complete as per manufacturers
specification & direction of Engineer-in-charge | Sqm | 333.9 | 333.9 | 78.0 | False | None | None | False | None | False | 26044.2 | 0 | 2881479 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled
Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and
15x15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom
rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert
for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated
on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC
Designer beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.
-do- with both side prelam | Sqm | 2484.3 | 2484.3 | 23.4 | False | None | None | False | None | False | 58132.62 | 0 | 2881480 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 14.3.1 | Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid | No | 6275.85 | 6275.85 | 3.0 | False | None | None | False | None | False | 18827.55 | 0 | 2881481 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required:
14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests | No | 5128.2 | 5128.2 | 5.0 | False | None | None | False | None | False | 25641.0 | 0 | 2881482 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
taps, 32 mm C.P. brass waste of standard pattern, including painting of
fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm
C.P. brass pillar taps | No | 3236.1 | 3236.1 | 3.0 | False | None | None | False | None | False | 9708.3 | 0 | 2881483 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 14.8 | Providing and fixing white vitreous china pedestal for wash basin
completely recessed at the back for the reception of pipes and fittings. | No | 1494.15 | 1494.15 | 3.0 | False | None | None | False | None | False | 4482.45 | 0 | 2881484 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.53 | Constructing brick masonry chamber for underground C.I. inspection
chamber and bends with bricks in cement mortar 1:4 (1 cement : 4
coarse sand) C.I. cover with frame (light duty) 455x610 mm internal
dimensions, total weight of cover with frame to be not less than 38
kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab
with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20
mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand
: 10 graded stone aggregate 40 mm nominal size), inside plastering 12
mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished
smooth with a floating coat of neat cement on walls and bed concrete etc.
complete as per standard design: Inside dimensions 455x610 mm and
45 cm deep for single pipe line : With common burnt clay (non modular)
bricks of class designation 3.5 | No | 5924.1 | 5924.1 | 5.0 | False | None | None | False | None | False | 29620.5 | 0 | 2881485 | 94216 | None | PWD Uni SR 23-24 Vol-5 Item no. 10.1.7 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc. complete PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Rmtr | 431.55 | 431.55 | 20.0 | False | None | None | False | None | False | 8631.0 | 0 | 2881486 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.34 | Providing and placing on terrace (at all floor levels) polyethylene
water storage tank, IS : 12701 marked, with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank. | Ltr | 9.45 | 9.45 | 2000.0 | False | None | None | False | None | False | 18900.0 | 0 | 2881487 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.4.1 | Providing and fixing Brass full way valve gate with C.I. wheel of
approved quality (screwed end) :25 mm nominal bore | No | 576.45 | 576.45 | 4.0 | False | None | None | False | None | False | 2305.8 | 0 | 2881488 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 25 mm nominal dia Pipes | Rmtr | 333.9 | 333.9 | 200.0 | False | None | None | False | None | False | 66780.0 | 0 | 2881489 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.31.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge.
Internal work - Exposed on wall 15 mm nominal dia Pipes | Rmtr | 200.55 | 200.55 | 350.0 | False | None | None | False | None | False | 70192.5 | 0 | 2881490 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.2.1 | Providing and fixing brass bib cock of approved quality :
15 mm nominal bore | No | 300.3 | 300.3 | 12.0 | False | None | None | False | None | False | 3603.6 | 0 | 2881491 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 13.3.1 | Providing and fixing brass stop cock of approved quality :
15 mm nominal bore | No | 313.95 | 313.95 | 10.0 | False | None | None | False | None | False | 3139.5 | 0 | 2881492 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,
shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase
AC supply conforming to ISS-374- 1979 and with double ball bearing
system. 48" Sweep (1200 mm) Regular model | No | 3133.2 | 3133.2 | 32.0 | False | None | None | False | None | False | 100262.4 | 0 | 2881493 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 13.11 | Fixing a ceiling /wall mounting fan of all capacities and all types,
with necessary clamps and 'S' hook made out of 15mm dia MS rod,
with 5 A. ceiling rose of approved quality with necessary length of
23/0.0076 inch PVC insulated twin twisted wire of approved quality,
mounted on a suitable size wooden board and wired. | Month | 330.75 | 330.75 | 32.0 | False | None | None | False | None | False | 10584.0 | 0 | 2881494 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 11.3.2 | Supplying of .feet -PVC Batten with integrated LED tube . W
with high quality diffuser with Life of 25000 burning hours & 70%
lumen maintenance with CRI 80. Power Input: 220-240V@
50/60Hz & Power factor 0.9 along with CE approved. 2 years
Warranty against any manufacturing defect working under standard
electrical condition. LED light fitting 1 x 4' - 20/22 W | No | 724.5 | 724.5 | 40.0 | False | None | None | False | None | False | 28980.0 | 0 | 2881495 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 13.7.1 | Fixing all types and all capacities of fluorescent /false ceiling / spot
light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders
using 23/0.0076" twin twisted PVC insulated wires, required Nos of
round blocks and clamps. On wall/ ceiling / Rafter / Girders | No | 128.1 | 128.1 | 40.0 | False | None | None | False | None | False | 5124.0 | 0 | 2881496 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 6.2.1 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades
suitable to operate on 230V 50Hz, AC Supply complete.
12" Sweep (300 mm) | No | 3117.45 | 3117.45 | 4.0 | False | None | None | False | None | False | 12469.8 | 0 | 2881497 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no.13.14 | Fixing one exhaust fan in the nitch already left in the wall with bolts
and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076
inch PVC insulated twin core wire. | No | 516.6 | 516.6 | 4.0 | False | None | None | False | None | False | 2066.4 | 0 | 2881498 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated
1100V grade, multistrand copper wire with low conductor resistance
single core in open or concealed system of wiring with specified IS694:2010 - 2.5 mm2 | Mtr | 44.1 | 44.1 | 250.0 | False | None | None | False | None | False | 11025.0 | 0 | 2881499 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box
suitable for mounting modular switch plates. The box should be firmly
flush mounted after due groove cutting in Brick/Stone/C.C wall- 4-5 Way | No | 185.85 | 185.85 | 12.0 | False | None | None | False | None | False | 2230.2 | 0 | 2881500 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 3.5.3 | Supplying and fixing superior quality modular switch mounting
polycarbonate plate with necessary supporting back plate with required
nos. of machine screws, bolts nuts etc., complete on the existing
metal/PVC box. - 4 module | No | 183.75 | 183.75 | 12.0 | False | None | None | False | None | False | 2205.0 | 0 | 2881501 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 3.6.1 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. - 6A One Way Switch | No | 107.1 | 107.1 | 48.0 | False | None | None | False | None | False | 5140.8 | 0 | 2881502 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 3.6.3 | Supplying and fixing of modular switch & connected accessories on
existing modular switch plate as per IS 3854 and IS 1293. - 6A Three Way socket | No | 179.55 | 179.55 | 12.0 | False | None | None | False | None | False | 2154.6 | 0 | 2881503 | 94216 | None | PWD Electrical SR 23-24 Vol-6 Item no. 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB
distribution boards using necessary fixing materials and 'C' Type
curve, indicator ON/OFF, energy cross-3 with Short circuit breaking
capacity of 10K and complete wiring as required confirming to IEC
60898. - 6-32 A SP | No | 435.75 | 435.75 | 10.0 | False | None | None | False | None | False | 4357.5 | 0 | 2881504 | 94216 | None | PWD Uni SR 23-24 Vol-2 Item no. 15.1 | Polyurethane based Single Component for New Surface
Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2
to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m2
and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification. | Sqm | 857.85 | 857.85 | 1315.19 | False | None | None | False | None | False | 1128235.7415 | 0 | 2881505 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes 100 mm diameter | Rmtr | 305.55 | 305.55 | 93.6 | False | None | None | False | None | False | 28599.48 | 0 | 2881506 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 20.89 | Repairs to plaster in patches of 2.5 m2
and less in walls, ceilings 10 to
20mm thick in cement mortar 1:4 including cutting the patches in proper
shape and replastering the surface of the wall including disposal of rubbish
with a lead of 50m including curing cost of materials, labour, complete
as per specification. | Sqm | 397.95 | 397.95 | 97.14 | False | None | None | False | None | False | 38656.863 | 0 | 2881507 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 8.25 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 3661.85 | False | None | None | False | None | False | 526757.1225 | 0 | 2881508 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 1435.3 | False | None | None | False | None | False | 262229.31 | 0 | 2881509 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 156.87 | False | None | None | False | None | False | 22730.463 | 0 | 2881510 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 259.82 | False | None | None | False | None | False | 37920.729 | 0 | 2881511 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 20.106 | Providing and fixing reeded glass 3mm thick with teakwood beading of
10mm thick. | Sqm | 1141.35 | 1141.35 | 14.04 | False | None | None | False | None | False | 16024.554 | 0 | 2881512 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal
braces including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-inCharge. | Sqm | 4701.9 | 4701.9 | 3.6 | False | None | None | False | None | False | 16926.84 | 0 | 2881513 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 11.5.1 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6
mm angle iron and 3 mm M.S. gusset plates at the junctions and
corners, all necessary fittings complete, including applying a priming
coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal
braces including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-inCharge. | Sqm | 4701.9 | 4701.9 | 3.6 | False | None | None | False | None | False | 16926.84 | 0 | 2881514 | 94216 | None | PWD UNI SR 23-24 Vol-2 Item no. 11.29.2 | Providing & fixing fly proof wire gauze to windows, clerestory
windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm
aperture on both sides including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the
Engineer-in-Charge. | Sqm | 905.1 | 905.1 | 55.8 | False | None | None | False | None | False | 50504.58 | 0 | 2881515 | 94216 | None | Item1 | KKRDB Logo Board | Each | 6000.0 | 6000.0 | 1.0 | False | None | None | False | None | False | 6000.0 | 0 | 2881516 | 94216 | None | PWD SR 2023 24 Vol2 Sl 11.57.2 P.No 95 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length | Kg | 118.65 | 118.65 | 190.0 | False | None | None | False | None | False | 22543.5 | 0 | 2881517 | 94216 | None | PWD SR 2023 24 Vol 2 Sl 11.57.1 P.No 95 | Fencing with G.I. barbed wire Angle iron post placed at required distance embedded embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost | m | 18.9 | 18.9 | 477.0 | False | None | None | False | None | False | 9015.3 | 0 |
|
|
---|