tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1708927450000 | 1 | None | None | Buildings | CONSTRUCTION OF GOVT. PU COLLEGE AT KIKKERI VILLAGE IN K.R PET TALUK, MANDYA DISTRICT. | 4175611.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2808101 | 90463 | None | I.No-1.1 VOL-1 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
| Cum | 91.0 | 91.0 | 84.0 | False | None | None | False | None | False | 7644.0 | 0 | 2808102 | 90463 | None | P.No- 5, I.No-1.4.1 PWD SR VOL-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m
| Cum | 242.0 | 242.0 | 173.61 | False | None | None | False | None | False | 42013.62 | 0 | 2808103 | 90463 | None | P.No- 15, I.No-2.1.3 VOL-1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates"
| Cum | 5989.0 | 5989.0 | 56.79 | False | None | None | False | None | False | 340115.31 | 0 | 2808104 | 90463 | None | P.No- 15, I.No-2.2.1 VOL-1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6790.0 | 6790.0 | 29.38 | False | None | None | False | None | False | 199490.2 | 0 | 2808105 | 90463 | None | P.No- 16, I.No-2.3.1 VOL-1 | Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9484.5 | 9484.5 | 7.49 | False | None | None | False | None | False | 71038.905 | 0 | 2808106 | 90463 | None | P.No- 17, I.No-2.5.1 VOL-1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 11271.0 | 11271.0 | 9.73 | False | None | None | False | None | False | 109666.83 | 0 | 2808107 | 90463 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 10608.0 | 10608.0 | 14.55 | False | None | None | False | None | False | 154346.4 | 0 | 2808108 | 90463 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9945.0 | 9945.0 | 38.55 | False | None | None | False | None | False | 383379.75 | 0 | 2808109 | 90463 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9613.5 | 9613.5 | 1.95 | False | None | None | False | None | False | 18746.325 | 0 | 2808110 | 90463 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6630.0 | 6630.0 | 7.01 | False | None | None | False | None | False | 46476.3 | 0 | 2808111 | 90463 | None | VOL-2 P.No- 9, I.No-5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6389.0 | 6389.0 | 56.91 | False | None | None | False | None | False | 363597.99 | 0 | 2808112 | 90463 | None | VOL-1 P.No- 7, I.No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 266.0 | 266.0 | 165.41 | False | None | None | False | None | False | 43999.06 | 0 | 2808113 | 90463 | None | VOL-1 P.No- 7, I.No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 474.0 | 474.0 | 45.2 | False | None | None | False | None | False | 21424.8 | 0 | 2808114 | 90463 | None | VOL-2 P.No- 14, I.No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7969.0 | 7969.0 | 50.21 | False | None | None | False | None | False | 400123.49 | 0 | 2808115 | 90463 | None | P.No-44, I.No-8.16a VOL-2 2023-24 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.
| Sqm | 1238.0 | 1238.0 | 9.07 | False | None | None | False | None | False | 11228.66 | 0 | 2808116 | 90463 | None | VOL-1 P.No- 18, I.No-2.11-a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
Buildings"
| Hour | 89457.0 | 89457.0 | 10.11 | False | None | None | False | None | False | 904410.27 | 0 | 2808117 | 90463 | None | P.No-77, I.No-11.5.1, PWD SR VOL-2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Sqm | 4478.0 | 4478.0 | 6.5 | False | None | None | False | None | False | 29107.0 | 0 | 2808118 | 90463 | None | P.No-79, I.No-11.11.1, PWD SR VOL-2 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 148.0 | 148.0 | 889.0 | False | None | None | False | None | False | 131572.0 | 0 | 2808119 | 90463 | None | VOL-2 P.No- 41, I.No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 255.0 | 255.0 | 258.89 | False | None | None | False | None | False | 66016.95 | 0 | 2808120 | 90463 | None | VOL-2 P.No- 41, I.No-8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 333.0 | 333.0 | 388.91 | False | None | None | False | None | False | 129507.03 | 0 | 2808121 | 90463 | None | VOL-2 P.No- 50, I.No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 100.0 | 100.0 | 647.8 | False | None | None | False | None | False | 64780.0 | 0 | 2808122 | 90463 | None | VOL-2 P.No- 42, I.No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 349.0 | 349.0 | 234.25 | False | None | None | False | None | False | 81753.25 | 0 | 2808123 | 90463 | None | VOL-2 P.No- 60, I.No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm"
| Sqm | 1145.0 | 1145.0 | 245.47 | False | None | None | False | None | False | 281063.15 | 0 | 2808124 | 90463 | None | VOL-2 P.No- 63, I.No-9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent.
| Sqm | 2466.0 | 2466.0 | 32.75 | False | None | None | False | None | False | 80761.5 | 0 | 2808125 | 90463 | None | VOL-2 P.No- 45, I.No-8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 647.6 | False | None | None | False | None | False | 88721.2 | 0 | 2808126 | 90463 | None | VOL-2 P.No- 45, I.No-8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 53.0 | 53.0 | 196.65 | False | None | None | False | None | False | 10422.45 | 0 | 2808127 | 90463 | None | VOL-2 P.No- 45, I.No-8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 89.0 | 89.0 | 196.65 | False | None | None | False | None | False | 17501.85 | 0 | 2808128 | 90463 | None | VOL-2 P.No- 44, I.No-8.19.1 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 255.0 | 255.0 | 18.16 | False | None | None | False | None | False | 4630.8 | 0 | 2808129 | 90463 | None | VOL-2 P.No- 48, I.No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 167.0 | 167.0 | 104.02 | False | None | None | False | None | False | 17371.34 | 0 | 2808130 | 90463 | None | VOL-2 P.No- 75, I.No-11.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fi in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kgs | 113.0 | 113.0 | 234.17 | False | None | None | False | None | False | 26461.21 | 0 | 2808131 | 90463 | None | VOL-2 P.No- 1st addenda, I.No-13.48 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter
| m | 291.0 | 291.0 | 34.0 | False | None | None | False | None | False | 9894.0 | 0 | 2808132 | 90463 | None | VOL-2 P.No- 49, I.No-8.49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| cm | 4.0 | 4.0 | 1000.0 | False | None | None | False | None | False | 4000.0 | 0 | 2808133 | 90463 | None | VOL-2 P.No- 107, I.No-12.68.1 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
125x65x2.12mm
| Nos | 55.0 | 55.0 | 6.0 | False | None | None | False | None | False | 330.0 | 0 | 2808134 | 90463 | None | VOL-2 P.No- 107, I.No-12.68.3 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
75x47x1.7mm | Nos | 38.0 | 38.0 | 120.0 | False | None | None | False | None | False | 4560.0 | 0 | 2808135 | 90463 | None | VOL-2 P.No- 108, I.No-12.72 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
| Nos | 82.0 | 82.0 | 46.0 | False | None | None | False | None | False | 3772.0 | 0 | 2808136 | 90463 | None | VOL-2 P.No- 108, I.No-12.73.1 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
125mm"
| Nos | 44.0 | 44.0 | 4.0 | False | None | None | False | None | False | 176.0 | 0 | 2808137 | 90463 | None | VOL-2 P.No- 108, I.No-12.73.3 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
75mm"
| Nos | 31.0 | 31.0 | 40.0 | False | None | None | False | None | False | 1240.0 | 0 | 2808138 | 90463 | None | VOL-2 P.No- 107, I.No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| Nos | 1052.0 | 1052.0 | 2.0 | False | None | None | False | None | False | 2104.0 | 0 | 2808139 | 90463 | None | P.No-175, I.No-17.3, PWD SR VOL-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
| 1 EACH | 1002.0 | 1002.0 | 1.41 | False | None | None | False | None | False | 1412.82 | 0 | 2808140 | 90463 | None | P.No-175, I.No-17.3, PWD SR VOL-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to
2 mm in recharge pit, in required thickness over gravel layer, for all leads
& lifts, all complete as per direction of Engineer -in-charge. | Cum | 1192.0 | 1192.0 | 0.63 | False | None | None | False | None | False | 750.96 | 0 |
| 1708927450000 | 1 | None | None | Buildings | FIRST FLOOR | 1815797.46 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2808141 | 90464 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 11383.7 | 11383.7 | 5.07 | False | None | None | False | None | False | 57715.359 | 0 | 2808142 | 90464 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 10714.1 | 10714.1 | 8.93 | False | None | None | False | None | False | 95676.913 | 0 | 2808143 | 90464 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 10044.5 | 10044.5 | 21.64 | False | None | None | False | None | False | 217362.98 | 0 | 2808144 | 90464 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9709.6 | 9709.6 | 0.93 | False | None | None | False | None | False | 9029.928 | 0 | 2808145 | 90464 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6630.0 | 6630.0 | 8.72 | False | None | None | False | None | False | 57813.6 | 0 | 2808146 | 90464 | None | VOL-2 P.No- 14, I.No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8048.7 | 8048.7 | 43.84 | False | None | None | False | None | False | 352855.008 | 0 | 2808147 | 90464 | None | VOL-2 P.No-44, I.No-8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.
| Sqm | 1250.4 | 1250.4 | 5.83 | False | None | None | False | None | False | 7289.832 | 0 | 2808148 | 90464 | None | VOL-1 P.No- 18, I.No-2.11-a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
Buildings"
| Kgs | 90351.6 | 90351.6 | 4.6 | False | None | None | False | None | False | 415617.36 | 0 | 2808149 | 90464 | None | P.No-77, I.No-11.5.1, PWD SR VOL-2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Cum | 4522.8 | 4522.8 | 3.25 | False | None | None | False | None | False | 14699.1 | 0 | 2808150 | 90464 | None | P.No-79, I.No-11.11.1, PWD SR VOL-2 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kgs | 149.5 | 149.5 | 465.5 | False | None | None | False | None | False | 69592.25 | 0 | 2808151 | 90464 | None | VOL-2 P.No- 85, I.No-11.34B | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
| Kgs | 184.8 | 184.8 | 123.5 | False | None | None | False | None | False | 22822.8 | 0 | 2808152 | 90464 | None | VOL-2 P.No- 41, I.No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 257.6 | 257.6 | 151.02 | False | None | None | False | None | False | 38902.752 | 0 | 2808153 | 90464 | None | VOL-2 P.No- 41, I.No-8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 336.3 | 336.3 | 227.96 | False | None | None | False | None | False | 76662.948 | 0 | 2808154 | 90464 | None | VOL-2 P.No- 50, I.No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 101.0 | 101.0 | 378.97 | False | None | None | False | None | False | 38275.97 | 0 | 2808155 | 90464 | None | VOL-2 P.No- 42, I.No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 352.5 | 352.5 | 278.99 | False | None | None | False | None | False | 98343.975 | 0 | 2808156 | 90464 | None | VOL-2 P.No- 60, I.No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm"
| Sqm | 1156.5 | 1156.5 | 115.35 | False | None | None | False | None | False | 133402.275 | 0 | 2808157 | 90464 | None | VOL-2 P.No- 45, I.No-8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 138.4 | 138.4 | 378.97 | False | None | None | False | None | False | 52449.448 | 0 | 2808158 | 90464 | None | VOL-2 P.No- 45, I.No-8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 53.5 | 53.5 | 278.99 | False | None | None | False | None | False | 14925.965 | 0 | 2808159 | 90464 | None | VOL-2 P.No- 45, I.No-8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 89.9 | 89.9 | 278.99 | False | None | None | False | None | False | 25081.201 | 0 | 2808160 | 90464 | None | VOL-2 P.No- 48, I.No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 168.7 | 168.7 | 52.01 | False | None | None | False | None | False | 8774.087 | 0 | 2808161 | 90464 | None | VOL-2 P.No- 1st addenda, I.No-13.48 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter
| m | 293.9 | 293.9 | 8.0 | False | None | None | False | None | False | 2351.2 | 0 | 2808162 | 90464 | None | VOL-2 P.No- 107, I.No-12.68.1 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
125x65x2.12mm"
| Nos | 55.6 | 55.6 | 3.0 | False | None | None | False | None | False | 166.8 | 0 | 2808163 | 90464 | None | VOL-2 P.No- 107, I.No-12.68.3 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
75x47x1.7mm"
| Nos | 38.4 | 38.4 | 60.0 | False | None | None | False | None | False | 2304.0 | 0 | 2808164 | 90464 | None | VOL-2 P.No- 108, I.No-12.72 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
| Nos | 82.8 | 82.8 | 23.0 | False | None | None | False | None | False | 1904.4 | 0 | 2808165 | 90464 | None | VOL-2 P.No- 108, I.No-12.73.1 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
125mm"
| Nos | 44.4 | 44.4 | 2.0 | False | None | None | False | None | False | 88.8 | 0 | 2808166 | 90464 | None | VOL-2 P.No- 108, I.No-12.73.3 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
75mm"
| Nos | 31.3 | 31.3 | 20.0 | False | None | None | False | None | False | 626.0 | 0 | 2808167 | 90464 | None | VOL-2 P.No- 107, I.No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| Nos | 1062.5 | 1062.5 | 1.0 | False | None | None | False | None | False | 1062.5 | 0 |
| 1708927450000 | 1 | None | None | Buildings | ELECTRICAL WORKS | 133549.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2808168 | 90465 | None | 1.2.2 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia .mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.(2/1.2.2) 25mm dia 2mm thick
| m | 78.0 | 78.0 | 180.0 | False | None | None | False | None | False | 14040.0 | 0 | 2808169 | 90465 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe ….dia ….mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. (2/1.3.2) 25mm dia 2mm thick
| m | 79.0 | 79.0 | 90.0 | False | None | None | False | None | False | 7110.0 | 0 | 2808170 | 90465 | None | 1.6.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm)(3/1.6.3)
| Each | 112.0 | 112.0 | 12.0 | False | None | None | False | None | False | 1344.0 | 0 | 2808171 | 90465 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws(9/3.8)
| Sq CM | 0.41 | 0.41 | 6000.0 | False | None | None | False | None | False | 2460.0 | 0 | 2808172 | 90465 | None | 2.1.1 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(5/2.1.1) Short point up to 3Mtr from tapping point to out let via switch
| Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | 2808173 | 90465 | None | 2.1.2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.2) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch
| Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 | 2808174 | 90465 | None | 2.1.3 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.3) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box
| Point | 570.0 | 570.0 | 18.0 | False | None | None | False | None | False | 10260.0 | 0 | 2808175 | 90465 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654(8/3.1.2) 6A 3/5 Way
| Each | 147.0 | 147.0 | 15.0 | False | None | None | False | None | False | 2205.0 | 0 | 2808176 | 90465 | None | 3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.1) 6A SP Switch
| Each | 55.0 | 55.0 | 30.0 | False | None | None | False | None | False | 1650.0 | 0 | 2808177 | 90465 | None | 3.14.6 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.6)6A Pendant Holder
| Each | 71.0 | 71.0 | 30.0 | False | None | None | False | None | False | 2130.0 | 0 | 2808178 | 90465 | None | 3.14.16 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16)
| Each | 281.0 | 281.0 | 3.0 | False | None | None | False | None | False | 843.0 | 0 | 2808179 | 90465 | None | 3.14.16 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16)
| No | 117.0 | 117.0 | 9.0 | False | None | None | False | None | False | 1053.0 | 0 | 2808180 | 90465 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.3) 2.5 mm2
| m | 42.0 | 42.0 | 375.0 | False | None | None | False | None | False | 15750.0 | 0 | 2808181 | 90465 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.5) 6 mm2
| m | 92.0 | 92.0 | 150.0 | False | None | None | False | None | False | 13800.0 | 0 | 2808182 | 90465 | None | 3.10.2 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.(9/3.10.2) 80/90mm
| Nos | 15.0 | 15.0 | 8.0 | False | None | None | False | None | False | 120.0 | 0 | 2808183 | 90465 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (17/5.18.4)6-32 Amps DP
| Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 2808184 | 90465 | None | 5.19.7 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( 18/5.19.7)II - Double Door 6 Way SP & N
| Each | 1791.0 | 1791.0 | 2.0 | False | None | None | False | None | False | 3582.0 | 0 | 2808185 | 90465 | None | 164.78 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Water Supply 164/45/ P430A)
| Job | 3750.0 | 3750.0 | 2.0 | False | None | None | False | None | False | 7500.0 | 0 | 2808186 | 90465 | None | 11.3.2 | Supplying of . feet - LED PVC Square Batten .W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI Morethan 80. Power Input: 220-240V at 50Hz & Power factor morethan 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4- 20/22 w (43/11.3.2) | Nos | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 | 2808187 | 90465 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (56/13.7.1)On wall / ceiling /Rafter / Girders
| Each | 112.0 | 112.0 | 20.0 | False | None | None | False | None | False | 2240.0 | 0 | 2808188 | 90465 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200mm) Regular model (30/6.3.1)
| Nos | 2984.0 | 2984.0 | 9.0 | False | None | None | False | None | False | 26856.0 | 0 | 2808189 | 90465 | None | 13.10 | Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (57/13.10)
| Each | 171.0 | 171.0 | 9.0 | False | None | None | False | None | False | 1539.0 | 0 |
| 1708927834000 | 0 | None | None | Buildings | CONSTRUCTION OF GOVT. PU COLLEGE AT KIKKERI VILLAGE IN K.R PET TALUK, MANDYA DISTRICT. | 6124957.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2808343 | 90473 | None | I.No-1.1 VOL-1 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.
| Cum | 91.0 | 91.0 | 84.0 | False | None | None | False | None | False | 7644.0 | 0 | 2808410 | 90473 | None | 1.2.2 | Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia .mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.(2/1.2.2) 25mm dia 2mm thick
| m | 78.0 | 78.0 | 180.0 | False | None | None | False | None | False | 14040.0 | 0 | 2808383 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 11383.7 | 11383.7 | 5.07 | False | None | None | False | None | False | 57715.359 | 0 | 2808384 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 10714.1 | 10714.1 | 8.93 | False | None | None | False | None | False | 95676.913 | 0 | 2808344 | 90473 | None | P.No- 5, I.No-1.4.1 PWD SR VOL-1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.
In all kinds of soils Depth upto 1.5 m
| Cum | 242.0 | 242.0 | 173.61 | False | None | None | False | None | False | 42013.62 | 0 | 2808411 | 90473 | None | 1.3.2 | Supplying heavy gauge PVC Conduit Pipe ….dia ….mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. (2/1.3.2) 25mm dia 2mm thick
| m | 79.0 | 79.0 | 90.0 | False | None | None | False | None | False | 7110.0 | 0 | 2808385 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 10044.5 | 10044.5 | 21.64 | False | None | None | False | None | False | 217362.98 | 0 | 2808412 | 90473 | None | 1.6.3 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm)(3/1.6.3)
| Each | 112.0 | 112.0 | 12.0 | False | None | None | False | None | False | 1344.0 | 0 | 2808345 | 90473 | None | P.No- 15, I.No-2.1.3 VOL-1 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates"
| Cum | 5989.0 | 5989.0 | 56.79 | False | None | None | False | None | False | 340115.31 | 0 | 2808386 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9709.6 | 9709.6 | 0.93 | False | None | None | False | None | False | 9029.928 | 0 | 2808346 | 90473 | None | P.No- 15, I.No-2.2.1 VOL-1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6790.0 | 6790.0 | 29.38 | False | None | None | False | None | False | 199490.2 | 0 | 2808413 | 90473 | None | 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws(9/3.8)
| Sq CM | 0.41 | 0.41 | 6000.0 | False | None | None | False | None | False | 2460.0 | 0 | 2808387 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6630.0 | 6630.0 | 8.72 | False | None | None | False | None | False | 57813.6 | 0 | 2808414 | 90473 | None | 2.1.1 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(5/2.1.1) Short point up to 3Mtr from tapping point to out let via switch
| Point | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 | 2808347 | 90473 | None | P.No- 16, I.No-2.3.1 VOL-1 | Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9484.5 | 9484.5 | 7.49 | False | None | None | False | None | False | 71038.905 | 0 | 2808415 | 90473 | None | 2.1.2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.2) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch
| Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 | 2808388 | 90473 | None | VOL-2 P.No- 14, I.No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.
| Cum | 8048.7 | 8048.7 | 43.84 | False | None | None | False | None | False | 352855.008 | 0 | 2808348 | 90473 | None | P.No- 17, I.No-2.5.1 VOL-1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 11271.0 | 11271.0 | 9.73 | False | None | None | False | None | False | 109666.83 | 0 | 2808389 | 90473 | None | VOL-2 P.No-44, I.No-8.16a | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.
| Sqm | 1250.4 | 1250.4 | 5.83 | False | None | None | False | None | False | 7289.832 | 0 | 2808349 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 10608.0 | 10608.0 | 14.55 | False | None | None | False | None | False | 154346.4 | 0 | 2808416 | 90473 | None | 2.1.3 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.3) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box
| Point | 570.0 | 570.0 | 18.0 | False | None | None | False | None | False | 10260.0 | 0 | 2808350 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9945.0 | 9945.0 | 38.55 | False | None | None | False | None | False | 383379.75 | 0 | 2808417 | 90473 | None | 3.1.2 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654(8/3.1.2) 6A 3/5 Way
| Each | 147.0 | 147.0 | 15.0 | False | None | None | False | None | False | 2205.0 | 0 | 2808390 | 90473 | None | VOL-1 P.No- 18, I.No-2.11-a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
Buildings"
| Kgs | 90351.6 | 90351.6 | 4.6 | False | None | None | False | None | False | 415617.36 | 0 | 2808351 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 9613.5 | 9613.5 | 1.95 | False | None | None | False | None | False | 18746.325 | 0 | 2808418 | 90473 | None | 3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.1) 6A SP Switch
| Each | 55.0 | 55.0 | 30.0 | False | None | None | False | None | False | 1650.0 | 0 | 2808391 | 90473 | None | P.No-77, I.No-11.5.1, PWD SR VOL-2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Cum | 4522.8 | 4522.8 | 3.25 | False | None | None | False | None | False | 14699.1 | 0 | 2808352 | 90473 | None | VOL-1 P.No- 17, I.No-2.5.1 | Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates"
| Cum | 6630.0 | 6630.0 | 7.01 | False | None | None | False | None | False | 46476.3 | 0 | 2808419 | 90473 | None | 3.14.6 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.6)6A Pendant Holder
| Each | 71.0 | 71.0 | 30.0 | False | None | None | False | None | False | 2130.0 | 0 | 2808392 | 90473 | None | P.No-79, I.No-11.11.1, PWD SR VOL-2 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kgs | 149.5 | 149.5 | 465.5 | False | None | None | False | None | False | 69592.25 | 0 | 2808393 | 90473 | None | VOL-2 P.No- 85, I.No-11.34B | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.
| Kgs | 184.8 | 184.8 | 123.5 | False | None | None | False | None | False | 22822.8 | 0 | 2808353 | 90473 | None | VOL-2 P.No- 9, I.No-5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
| Cum | 6389.0 | 6389.0 | 56.91 | False | None | None | False | None | False | 363597.99 | 0 | 2808420 | 90473 | None | 3.14.16 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16)
| Each | 281.0 | 281.0 | 3.0 | False | None | None | False | None | False | 843.0 | 0 | 2808394 | 90473 | None | VOL-2 P.No- 41, I.No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 257.6 | 257.6 | 151.02 | False | None | None | False | None | False | 38902.752 | 0 | 2808421 | 90473 | None | 3.14.16 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16)
| No | 117.0 | 117.0 | 9.0 | False | None | None | False | None | False | 1053.0 | 0 | 2808354 | 90473 | None | VOL-1 P.No- 7, I.No-1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
| Cum | 266.0 | 266.0 | 165.41 | False | None | None | False | None | False | 43999.06 | 0 | 2808395 | 90473 | None | VOL-2 P.No- 41, I.No-8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 336.3 | 336.3 | 227.96 | False | None | None | False | None | False | 76662.948 | 0 | 2808355 | 90473 | None | VOL-1 P.No- 7, I.No-1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.
| Cum | 474.0 | 474.0 | 45.2 | False | None | None | False | None | False | 21424.8 | 0 | 2808422 | 90473 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.3) 2.5 mm2
| m | 42.0 | 42.0 | 375.0 | False | None | None | False | None | False | 15750.0 | 0 | 2808396 | 90473 | None | VOL-2 P.No- 50, I.No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 101.0 | 101.0 | 378.97 | False | None | None | False | None | False | 38275.97 | 0 | 2808356 | 90473 | None | VOL-2 P.No- 14, I.No-6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 7969.0 | 7969.0 | 50.21 | False | None | None | False | None | False | 400123.49 | 0 | 2808423 | 90473 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.5) 6 mm2
| m | 92.0 | 92.0 | 150.0 | False | None | None | False | None | False | 13800.0 | 0 | 2808397 | 90473 | None | VOL-2 P.No- 42, I.No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 352.5 | 352.5 | 278.99 | False | None | None | False | None | False | 98343.975 | 0 | 2808357 | 90473 | None | P.No-44, I.No-8.16a VOL-2 2023-24 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications.
| Sqm | 1238.0 | 1238.0 | 9.07 | False | None | None | False | None | False | 11228.66 | 0 | 2808424 | 90473 | None | 3.10.2 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.(9/3.10.2) 80/90mm
| Nos | 15.0 | 15.0 | 8.0 | False | None | None | False | None | False | 120.0 | 0 | 2808358 | 90473 | None | VOL-1 P.No- 18, I.No-2.11-a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification
Buildings"
| Hour | 89457.0 | 89457.0 | 10.11 | False | None | None | False | None | False | 904410.27 | 0 | 2808425 | 90473 | None | 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (17/5.18.4)6-32 Amps DP
| Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 2808398 | 90473 | None | VOL-2 P.No- 60, I.No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm"
| Sqm | 1156.5 | 1156.5 | 115.35 | False | None | None | False | None | False | 133402.275 | 0 | 2808399 | 90473 | None | VOL-2 P.No- 45, I.No-8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 138.4 | 138.4 | 378.97 | False | None | None | False | None | False | 52449.448 | 0 | 2808426 | 90473 | None | 5.19.7 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( 18/5.19.7)II - Double Door 6 Way SP & N
| Each | 1791.0 | 1791.0 | 2.0 | False | None | None | False | None | False | 3582.0 | 0 | 2808359 | 90473 | None | P.No-77, I.No-11.5.1, PWD SR VOL-2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Sqm | 4478.0 | 4478.0 | 6.5 | False | None | None | False | None | False | 29107.0 | 0 | 2808400 | 90473 | None | VOL-2 P.No- 45, I.No-8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 53.5 | 53.5 | 278.99 | False | None | None | False | None | False | 14925.965 | 0 | 2808427 | 90473 | None | 164.78 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Water Supply 164/45/ P430A)
| Job | 3750.0 | 3750.0 | 2.0 | False | None | None | False | None | False | 7500.0 | 0 | 2808360 | 90473 | None | P.No-79, I.No-11.11.1, PWD SR VOL-2 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kg | 148.0 | 148.0 | 889.0 | False | None | None | False | None | False | 131572.0 | 0 | 2808401 | 90473 | None | VOL-2 P.No- 45, I.No-8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 89.9 | 89.9 | 278.99 | False | None | None | False | None | False | 25081.201 | 0 | 2808428 | 90473 | None | 11.3.2 | Supplying of . feet - LED PVC Square Batten .W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI Morethan 80. Power Input: 220-240V at 50Hz & Power factor morethan 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4- 20/22 w (43/11.3.2) | Nos | 690.0 | 690.0 | 20.0 | False | None | None | False | None | False | 13800.0 | 0 | 2808361 | 90473 | None | VOL-2 P.No- 41, I.No-8.1.1 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 255.0 | 255.0 | 258.89 | False | None | None | False | None | False | 66016.95 | 0 | 2808429 | 90473 | None | 13.7.1 | Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (56/13.7.1)On wall / ceiling /Rafter / Girders
| Each | 112.0 | 112.0 | 20.0 | False | None | None | False | None | False | 2240.0 | 0 | 2808402 | 90473 | None | VOL-2 P.No- 48, I.No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 168.7 | 168.7 | 52.01 | False | None | None | False | None | False | 8774.087 | 0 | 2808362 | 90473 | None | VOL-2 P.No- 41, I.No-8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 333.0 | 333.0 | 388.91 | False | None | None | False | None | False | 129507.03 | 0 | 2808363 | 90473 | None | VOL-2 P.No- 50, I.No-8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.
| Sqm | 100.0 | 100.0 | 647.8 | False | None | None | False | None | False | 64780.0 | 0 | 2808430 | 90473 | None | 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200mm) Regular model (30/6.3.1)
| Nos | 2984.0 | 2984.0 | 9.0 | False | None | None | False | None | False | 26856.0 | 0 | 2808403 | 90473 | None | VOL-2 P.No- 1st addenda, I.No-13.48 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter
| m | 293.9 | 293.9 | 8.0 | False | None | None | False | None | False | 2351.2 | 0 | 2808431 | 90473 | None | 13.10 | Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (57/13.10)
| Each | 171.0 | 171.0 | 9.0 | False | None | None | False | None | False | 1539.0 | 0 | 2808404 | 90473 | None | VOL-2 P.No- 107, I.No-12.68.1 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
125x65x2.12mm"
| Nos | 55.6 | 55.6 | 3.0 | False | None | None | False | None | False | 166.8 | 0 | 2808364 | 90473 | None | VOL-2 P.No- 42, I.No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 349.0 | 349.0 | 234.25 | False | None | None | False | None | False | 81753.25 | 0 | 2808405 | 90473 | None | VOL-2 P.No- 107, I.No-12.68.3 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
75x47x1.7mm"
| Nos | 38.4 | 38.4 | 60.0 | False | None | None | False | None | False | 2304.0 | 0 | 2808365 | 90473 | None | VOL-2 P.No- 60, I.No-9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm"
| Sqm | 1145.0 | 1145.0 | 245.47 | False | None | None | False | None | False | 281063.15 | 0 | 2808366 | 90473 | None | VOL-2 P.No- 63, I.No-9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent.
| Sqm | 2466.0 | 2466.0 | 32.75 | False | None | None | False | None | False | 80761.5 | 0 | 2808406 | 90473 | None | VOL-2 P.No- 108, I.No-12.72 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
| Nos | 82.8 | 82.8 | 23.0 | False | None | None | False | None | False | 1904.4 | 0 | 2808407 | 90473 | None | VOL-2 P.No- 108, I.No-12.73.1 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
125mm"
| Nos | 44.4 | 44.4 | 2.0 | False | None | None | False | None | False | 88.8 | 0 | 2808367 | 90473 | None | VOL-2 P.No- 45, I.No-8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 137.0 | 137.0 | 647.6 | False | None | None | False | None | False | 88721.2 | 0 | 2808368 | 90473 | None | VOL-2 P.No- 45, I.No-8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 53.0 | 53.0 | 196.65 | False | None | None | False | None | False | 10422.45 | 0 | 2808408 | 90473 | None | VOL-2 P.No- 108, I.No-12.73.3 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
75mm"
| Nos | 31.3 | 31.3 | 20.0 | False | None | None | False | None | False | 626.0 | 0 | 2808369 | 90473 | None | VOL-2 P.No- 45, I.No-8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 89.0 | 89.0 | 196.65 | False | None | None | False | None | False | 17501.85 | 0 | 2808409 | 90473 | None | VOL-2 P.No- 107, I.No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| Nos | 1062.5 | 1062.5 | 1.0 | False | None | None | False | None | False | 1062.5 | 0 | 2808370 | 90473 | None | VOL-2 P.No- 44, I.No-8.19.1 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.
| Sqm | 255.0 | 255.0 | 18.16 | False | None | None | False | None | False | 4630.8 | 0 | 2808371 | 90473 | None | VOL-2 P.No- 48, I.No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| Sqm | 167.0 | 167.0 | 104.02 | False | None | None | False | None | False | 17371.34 | 0 | 2808372 | 90473 | None | VOL-2 P.No- 75, I.No-11.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fi in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.
| Kgs | 113.0 | 113.0 | 234.17 | False | None | None | False | None | False | 26461.21 | 0 | 2808373 | 90473 | None | VOL-2 P.No- 1st addenda, I.No-13.48 | Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter
| m | 291.0 | 291.0 | 34.0 | False | None | None | False | None | False | 9894.0 | 0 | 2808374 | 90473 | None | VOL-2 P.No- 49, I.No-8.49 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
| cm | 4.0 | 4.0 | 1000.0 | False | None | None | False | None | False | 4000.0 | 0 | 2808375 | 90473 | None | VOL-2 P.No- 107, I.No-12.68.1 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
125x65x2.12mm
| Nos | 55.0 | 55.0 | 6.0 | False | None | None | False | None | False | 330.0 | 0 | 2808376 | 90473 | None | VOL-2 P.No- 107, I.No-12.68.3 | Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc.
75x47x1.7mm | Nos | 38.0 | 38.0 | 120.0 | False | None | None | False | None | False | 4560.0 | 0 | 2808377 | 90473 | None | VOL-2 P.No- 108, I.No-12.72 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete :
| Nos | 82.0 | 82.0 | 46.0 | False | None | None | False | None | False | 3772.0 | 0 | 2808378 | 90473 | None | VOL-2 P.No- 108, I.No-12.73.1 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
125mm"
| Nos | 44.0 | 44.0 | 4.0 | False | None | None | False | None | False | 176.0 | 0 | 2808379 | 90473 | None | VOL-2 P.No- 108, I.No-12.73.3 | Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete :
75mm"
| Nos | 31.0 | 31.0 | 40.0 | False | None | None | False | None | False | 1240.0 | 0 | 2808380 | 90473 | None | VOL-2 P.No- 107, I.No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
| Nos | 1052.0 | 1052.0 | 2.0 | False | None | None | False | None | False | 2104.0 | 0 | 2808381 | 90473 | None | P.No-175, I.No-17.3, PWD SR VOL-2 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
| 1 EACH | 1002.0 | 1002.0 | 1.41 | False | None | None | False | None | False | 1412.82 | 0 | 2808382 | 90473 | None | P.No-175, I.No-17.3, PWD SR VOL-2 | Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to
2 mm in recharge pit, in required thickness over gravel layer, for all leads
& lifts, all complete as per direction of Engineer -in-charge. | Cum | 1192.0 | 1192.0 | 0.63 | False | None | None | False | None | False | 750.96 | 0 |
|
|
---|