createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1708927449846
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee1540.00
emd123000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose15-03-2024 16:30:00
tenderQueryClose11-03-2024 16:00:00
technicalBidOpen16-03-2024 16:31:00
publishedDate28-02-2024 13:32:51
publishedByPostPWD_EE_DIV_MDY
publishedByUserKPE13520 - H R HARSHA
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonV R Varalakshmi
splitEmdRequiredYnTrue
emdBankGuarantee73000.00
emdCash50000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08232228605
mobileNumberNone
tenderSupplierListNone
tenderSchedule
createdTs1708927449876
version8
createdDateNone
modifiedDateNone
tenderNumberPWD/2023-24/BD/WORK_INDENT6890
titleCONSTRUCTION OF GOVT. PU COLLEGE AT KIKKERI VILLAGE IN K.R PET TALUK, MANDYA DISTRICT.
descriptionCONSTRUCTION OF GOVT. PU COLLEGE AT KIKKERI VILLAGE IN K.R PET TALUK, MANDYA DISTRICT.
categoryWORKS
categoryTextWorks
ecv6124957.87
deptNamePublic Works Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location1677
locationNamePWD Division Office Mandya
provisionalAmount7515000.0
groupOverheadTotal0.0
fileNumberPWD/AEE/KRP/2023-2024/KIKKERI/PUCOLLEGE
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17089274500001NoneNoneBuildingsCONSTRUCTION OF GOVT. PU COLLEGE AT KIKKERI VILLAGE IN K.R PET TALUK, MANDYA DISTRICT.4175611.41
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
280810190463NoneI.No-1.1 VOL-1Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Cum91.091.084.0FalseNoneNoneFalseNoneFalse7644.00
280810290463NoneP.No- 5, I.No-1.4.1 PWD SR VOL-1 Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m Cum242.0242.0173.61FalseNoneNoneFalseNoneFalse42013.620
280810390463NoneP.No- 15, I.No-2.1.3 VOL-1 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates" Cum5989.05989.056.79FalseNoneNoneFalseNoneFalse340115.310
280810490463NoneP.No- 15, I.No-2.2.1 VOL-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum6790.06790.029.38FalseNoneNoneFalseNoneFalse199490.20
280810590463NoneP.No- 16, I.No-2.3.1 VOL-1Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9484.59484.57.49FalseNoneNoneFalseNoneFalse71038.9050
280810690463NoneP.No- 17, I.No-2.5.1 VOL-1 Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum11271.011271.09.73FalseNoneNoneFalseNoneFalse109666.830
280810790463NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum10608.010608.014.55FalseNoneNoneFalseNoneFalse154346.40
280810890463NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9945.09945.038.55FalseNoneNoneFalseNoneFalse383379.750
280810990463NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9613.59613.51.95FalseNoneNoneFalseNoneFalse18746.3250
280811090463NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum6630.06630.07.01FalseNoneNoneFalseNoneFalse46476.30
280811190463NoneVOL-2 P.No- 9, I.No-5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum6389.06389.056.91FalseNoneNoneFalseNoneFalse363597.990
280811290463NoneVOL-1 P.No- 7, I.No-1.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum266.0266.0165.41FalseNoneNoneFalseNoneFalse43999.060
280811390463NoneVOL-1 P.No- 7, I.No-1.8 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum474.0474.045.2FalseNoneNoneFalseNoneFalse21424.80
280811490463NoneVOL-2 P.No- 14, I.No-6.8 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum7969.07969.050.21FalseNoneNoneFalseNoneFalse400123.490
280811590463NoneP.No-44, I.No-8.16a VOL-2 2023-24Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sqm1238.01238.09.07FalseNoneNoneFalseNoneFalse11228.660
280811690463NoneVOL-1 P.No- 18, I.No-2.11-aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings" Hour89457.089457.010.11FalseNoneNoneFalseNoneFalse904410.270
280811790463NoneP.No-77, I.No-11.5.1, PWD SR VOL-2 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Sqm4478.04478.06.5FalseNoneNoneFalseNoneFalse29107.00
280811890463NoneP.No-79, I.No-11.11.1, PWD SR VOL-2Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg148.0148.0889.0FalseNoneNoneFalseNoneFalse131572.00
280811990463NoneVOL-2 P.No- 41, I.No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm255.0255.0258.89FalseNoneNoneFalseNoneFalse66016.950
280812090463NoneVOL-2 P.No- 41, I.No-8.3.2Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm333.0333.0388.91FalseNoneNoneFalseNoneFalse129507.030
280812190463NoneVOL-2 P.No- 50, I.No-8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm100.0100.0647.8FalseNoneNoneFalseNoneFalse64780.00
280812290463NoneVOL-2 P.No- 42, I.No-8.5.2 Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm349.0349.0234.25FalseNoneNoneFalseNoneFalse81753.250
280812390463NoneVOL-2 P.No- 60, I.No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm" Sqm1145.01145.0245.47FalseNoneNoneFalseNoneFalse281063.150
280812490463NoneVOL-2 P.No- 63, I.No-9.23 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. Sqm2466.02466.032.75FalseNoneNoneFalseNoneFalse80761.50
280812590463NoneVOL-2 P.No- 45, I.No-8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm137.0137.0647.6FalseNoneNoneFalseNoneFalse88721.20
280812690463NoneVOL-2 P.No- 45, I.No-8.27 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm53.053.0196.65FalseNoneNoneFalseNoneFalse10422.450
280812790463NoneVOL-2 P.No- 45, I.No-8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm89.089.0196.65FalseNoneNoneFalseNoneFalse17501.850
280812890463NoneVOL-2 P.No- 44, I.No-8.19.1Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. Sqm255.0255.018.16FalseNoneNoneFalseNoneFalse4630.80
280812990463NoneVOL-2 P.No- 48, I.No-8.41 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm167.0167.0104.02FalseNoneNoneFalseNoneFalse17371.340
280813090463NoneVOL-2 P.No- 75, I.No-11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fi in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kgs113.0113.0234.17FalseNoneNoneFalseNoneFalse26461.210
280813190463NoneVOL-2 P.No- 1st addenda, I.No-13.48Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter m291.0291.034.0FalseNoneNoneFalseNoneFalse9894.00
280813290463NoneVOL-2 P.No- 49, I.No-8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. cm4.04.01000.0FalseNoneNoneFalseNoneFalse4000.00
280813390463NoneVOL-2 P.No- 107, I.No-12.68.1 Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 125x65x2.12mm Nos55.055.06.0FalseNoneNoneFalseNoneFalse330.00
280813490463NoneVOL-2 P.No- 107, I.No-12.68.3Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 75x47x1.7mmNos38.038.0120.0FalseNoneNoneFalseNoneFalse4560.00
280813590463NoneVOL-2 P.No- 108, I.No-12.72Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : Nos82.082.046.0FalseNoneNoneFalseNoneFalse3772.00
280813690463NoneVOL-2 P.No- 108, I.No-12.73.1 Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 125mm" Nos44.044.04.0FalseNoneNoneFalseNoneFalse176.00
280813790463NoneVOL-2 P.No- 108, I.No-12.73.3Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 75mm" Nos31.031.040.0FalseNoneNoneFalseNoneFalse1240.00
280813890463NoneVOL-2 P.No- 107, I.No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Nos1052.01052.02.0FalseNoneNoneFalseNoneFalse2104.00
280813990463NoneP.No-175, I.No-17.3, PWD SR VOL-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1 EACH1002.01002.01.41FalseNoneNoneFalseNoneFalse1412.820
280814090463NoneP.No-175, I.No-17.3, PWD SR VOL-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1192.01192.00.63FalseNoneNoneFalseNoneFalse750.960
17089274500001NoneNoneBuildingsFIRST FLOOR1815797.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
280814190464NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum11383.711383.75.07FalseNoneNoneFalseNoneFalse57715.3590
280814290464NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum10714.110714.18.93FalseNoneNoneFalseNoneFalse95676.9130
280814390464NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum10044.510044.521.64FalseNoneNoneFalseNoneFalse217362.980
280814490464NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9709.69709.60.93FalseNoneNoneFalseNoneFalse9029.9280
280814590464NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum6630.06630.08.72FalseNoneNoneFalseNoneFalse57813.60
280814690464NoneVOL-2 P.No- 14, I.No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum8048.78048.743.84FalseNoneNoneFalseNoneFalse352855.0080
280814790464NoneVOL-2 P.No-44, I.No-8.16aProviding lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sqm1250.41250.45.83FalseNoneNoneFalseNoneFalse7289.8320
280814890464NoneVOL-1 P.No- 18, I.No-2.11-aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings" Kgs90351.690351.64.6FalseNoneNoneFalseNoneFalse415617.360
280814990464NoneP.No-77, I.No-11.5.1, PWD SR VOL-2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Cum4522.84522.83.25FalseNoneNoneFalseNoneFalse14699.10
280815090464NoneP.No-79, I.No-11.11.1, PWD SR VOL-2Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kgs149.5149.5465.5FalseNoneNoneFalseNoneFalse69592.250
280815190464NoneVOL-2 P.No- 85, I.No-11.34B Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Kgs184.8184.8123.5FalseNoneNoneFalseNoneFalse22822.80
280815290464NoneVOL-2 P.No- 41, I.No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm257.6257.6151.02FalseNoneNoneFalseNoneFalse38902.7520
280815390464NoneVOL-2 P.No- 41, I.No-8.3.2Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm336.3336.3227.96FalseNoneNoneFalseNoneFalse76662.9480
280815490464NoneVOL-2 P.No- 50, I.No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm101.0101.0378.97FalseNoneNoneFalseNoneFalse38275.970
280815590464NoneVOL-2 P.No- 42, I.No-8.5.2 Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm352.5352.5278.99FalseNoneNoneFalseNoneFalse98343.9750
280815690464NoneVOL-2 P.No- 60, I.No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm" Sqm1156.51156.5115.35FalseNoneNoneFalseNoneFalse133402.2750
280815790464NoneVOL-2 P.No- 45, I.No-8.25 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm138.4138.4378.97FalseNoneNoneFalseNoneFalse52449.4480
280815890464NoneVOL-2 P.No- 45, I.No-8.27Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm53.553.5278.99FalseNoneNoneFalseNoneFalse14925.9650
280815990464NoneVOL-2 P.No- 45, I.No-8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm89.989.9278.99FalseNoneNoneFalseNoneFalse25081.2010
280816090464NoneVOL-2 P.No- 48, I.No-8.41 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm168.7168.752.01FalseNoneNoneFalseNoneFalse8774.0870
280816190464NoneVOL-2 P.No- 1st addenda, I.No-13.48Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter m293.9293.98.0FalseNoneNoneFalseNoneFalse2351.20
280816290464NoneVOL-2 P.No- 107, I.No-12.68.1Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 125x65x2.12mm" Nos55.655.63.0FalseNoneNoneFalseNoneFalse166.80
280816390464NoneVOL-2 P.No- 107, I.No-12.68.3Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 75x47x1.7mm" Nos38.438.460.0FalseNoneNoneFalseNoneFalse2304.00
280816490464NoneVOL-2 P.No- 108, I.No-12.72Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : Nos82.882.823.0FalseNoneNoneFalseNoneFalse1904.40
280816590464NoneVOL-2 P.No- 108, I.No-12.73.1 Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 125mm" Nos44.444.42.0FalseNoneNoneFalseNoneFalse88.80
280816690464NoneVOL-2 P.No- 108, I.No-12.73.3Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 75mm" Nos31.331.320.0FalseNoneNoneFalseNoneFalse626.00
280816790464NoneVOL-2 P.No- 107, I.No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Nos1062.51062.51.0FalseNoneNoneFalseNoneFalse1062.50
17089274500001NoneNoneBuildingsELECTRICAL WORKS133549.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
280816890465None1.2.2Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia .mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.(2/1.2.2) 25mm dia 2mm thick m78.078.0180.0FalseNoneNoneFalseNoneFalse14040.00
280816990465None1.3.2Supplying heavy gauge PVC Conduit Pipe ….dia ….mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. (2/1.3.2) 25mm dia 2mm thick m79.079.090.0FalseNoneNoneFalseNoneFalse7110.00
280817090465None1.6.3Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm)(3/1.6.3) Each112.0112.012.0FalseNoneNoneFalseNoneFalse1344.00
280817190465None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws(9/3.8) Sq CM0.410.416000.0FalseNoneNoneFalseNoneFalse2460.00
280817290465None2.1.1Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(5/2.1.1) Short point up to 3Mtr from tapping point to out let via switch Point285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
280817390465None2.1.2Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.2) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch Point394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
280817490465None2.1.3Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.3) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box Point570.0570.018.0FalseNoneNoneFalseNoneFalse10260.00
280817590465None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654(8/3.1.2) 6A 3/5 Way Each147.0147.015.0FalseNoneNoneFalseNoneFalse2205.00
280817690465None3.14.1Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.1) 6A SP Switch Each55.055.030.0FalseNoneNoneFalseNoneFalse1650.00
280817790465None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.6)6A Pendant Holder Each71.071.030.0FalseNoneNoneFalseNoneFalse2130.00
280817890465None3.14.16Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16) Each281.0281.03.0FalseNoneNoneFalseNoneFalse843.00
280817990465None3.14.16Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16) No117.0117.09.0FalseNoneNoneFalseNoneFalse1053.00
280818090465None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.3) 2.5 mm2 m42.042.0375.0FalseNoneNoneFalseNoneFalse15750.00
280818190465None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.5) 6 mm2 m92.092.0150.0FalseNoneNoneFalseNoneFalse13800.00
280818290465None3.10.2Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.(9/3.10.2) 80/90mm Nos15.015.08.0FalseNoneNoneFalseNoneFalse120.00
280818390465None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (17/5.18.4)6-32 Amps DP Each739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
280818490465None5.19.7Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( 18/5.19.7)II - Double Door 6 Way SP & N Each1791.01791.02.0FalseNoneNoneFalseNoneFalse3582.00
280818590465None164.78Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Water Supply 164/45/ P430A) Job3750.03750.02.0FalseNoneNoneFalseNoneFalse7500.00
280818690465None11.3.2Supplying of . feet - LED PVC Square Batten .W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI Morethan 80. Power Input: 220-240V at 50Hz & Power factor morethan 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4- 20/22 w (43/11.3.2)Nos690.0690.020.0FalseNoneNoneFalseNoneFalse13800.00
280818790465None13.7.1Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (56/13.7.1)On wall / ceiling /Rafter / Girders Each112.0112.020.0FalseNoneNoneFalseNoneFalse2240.00
280818890465None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200mm) Regular model (30/6.3.1) Nos2984.02984.09.0FalseNoneNoneFalseNoneFalse26856.00
280818990465None13.10Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (57/13.10) Each171.0171.09.0FalseNoneNoneFalseNoneFalse1539.00
17089278340000NoneNoneBuildingsCONSTRUCTION OF GOVT. PU COLLEGE AT KIKKERI VILLAGE IN K.R PET TALUK, MANDYA DISTRICT.6124957.87
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
280834390473NoneI.No-1.1 VOL-1Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. Cum91.091.084.0FalseNoneNoneFalseNoneFalse7644.00
280841090473None1.2.2Concealed Conduit System Supplying heavy PVC condiuit pipe ……mm dia .mm thick confirming to IS 2509 woth suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary.(2/1.2.2) 25mm dia 2mm thick m78.078.0180.0FalseNoneNoneFalseNoneFalse14040.00
280838390473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum11383.711383.75.07FalseNoneNoneFalseNoneFalse57715.3590
280838490473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum10714.110714.18.93FalseNoneNoneFalseNoneFalse95676.9130
280834490473NoneP.No- 5, I.No-1.4.1 PWD SR VOL-1 Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m Cum242.0242.0173.61FalseNoneNoneFalseNoneFalse42013.620
280841190473None1.3.2Supplying heavy gauge PVC Conduit Pipe ….dia ….mm thick with suitable size bends, metal junction boxes adhesive paste etx., by groove cutting in the wall and fixing by using U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. (2/1.3.2) 25mm dia 2mm thick m79.079.090.0FalseNoneNoneFalseNoneFalse7110.00
280838590473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum10044.510044.521.64FalseNoneNoneFalseNoneFalse217362.980
280841290473None1.6.3Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm)(3/1.6.3) Each112.0112.012.0FalseNoneNoneFalseNoneFalse1344.00
280834590473NoneP.No- 15, I.No-2.1.3 VOL-1 Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates" Cum5989.05989.056.79FalseNoneNoneFalseNoneFalse340115.310
280838690473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9709.69709.60.93FalseNoneNoneFalseNoneFalse9029.9280
280834690473NoneP.No- 15, I.No-2.2.1 VOL-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum6790.06790.029.38FalseNoneNoneFalseNoneFalse199490.20
280841390473None3.8Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws(9/3.8) Sq CM0.410.416000.0FalseNoneNoneFalseNoneFalse2460.00
280838790473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum6630.06630.08.72FalseNoneNoneFalseNoneFalse57813.60
280841490473None2.1.1Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(5/2.1.1) Short point up to 3Mtr from tapping point to out let via switch Point285.0285.05.0FalseNoneNoneFalseNoneFalse1425.00
280834790473NoneP.No- 16, I.No-2.3.1 VOL-1Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9484.59484.57.49FalseNoneNoneFalseNoneFalse71038.9050
280841590473None2.1.2Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.2) Medium point above 3mtr up to 6Mtr from tapping point to out let via switch Point394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
280838890473NoneVOL-2 P.No- 14, I.No-6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum8048.78048.743.84FalseNoneNoneFalseNoneFalse352855.0080
280834890473NoneP.No- 17, I.No-2.5.1 VOL-1 Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum11271.011271.09.73FalseNoneNoneFalseNoneFalse109666.830
280838990473NoneVOL-2 P.No-44, I.No-8.16aProviding lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sqm1250.41250.45.83FalseNoneNoneFalseNoneFalse7289.8320
280834990473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum10608.010608.014.55FalseNoneNoneFalseNoneFalse154346.40
280841690473None2.1.3Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated opper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.(3/2.1.3) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box Point570.0570.018.0FalseNoneNoneFalseNoneFalse10260.00
280835090473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9945.09945.038.55FalseNoneNoneFalseNoneFalse383379.750
280841790473None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654(8/3.1.2) 6A 3/5 Way Each147.0147.015.0FalseNoneNoneFalseNoneFalse2205.00
280839090473NoneVOL-1 P.No- 18, I.No-2.11-aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings" Kgs90351.690351.64.6FalseNoneNoneFalseNoneFalse415617.360
280835190473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum9613.59613.51.95FalseNoneNoneFalseNoneFalse18746.3250
280841890473None3.14.1Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.1) 6A SP Switch Each55.055.030.0FalseNoneNoneFalseNoneFalse1650.00
280839190473NoneP.No-77, I.No-11.5.1, PWD SR VOL-2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Cum4522.84522.83.25FalseNoneNoneFalseNoneFalse14699.10
280835290473NoneVOL-1 P.No- 17, I.No-2.5.1Providing and laying in position Reinforced cement concrete for allSuper structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates" Cum6630.06630.07.01FalseNoneNoneFalseNoneFalse46476.30
280841990473None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board (10/3.14.6)6A Pendant Holder Each71.071.030.0FalseNoneNoneFalseNoneFalse2130.00
280839290473NoneP.No-79, I.No-11.11.1, PWD SR VOL-2Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kgs149.5149.5465.5FalseNoneNoneFalseNoneFalse69592.250
280839390473NoneVOL-2 P.No- 85, I.No-11.34B Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Kgs184.8184.8123.5FalseNoneNoneFalseNoneFalse22822.80
280835390473NoneVOL-2 P.No- 9, I.No-5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Cum6389.06389.056.91FalseNoneNoneFalseNoneFalse363597.990
280842090473None3.14.16Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16) Each281.0281.03.0FalseNoneNoneFalseNoneFalse843.00
280839490473NoneVOL-2 P.No- 41, I.No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm257.6257.6151.02FalseNoneNoneFalseNoneFalse38902.7520
280842190473None3.14.16Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator (10/3.14.16) No117.0117.09.0FalseNoneNoneFalseNoneFalse1053.00
280835490473NoneVOL-1 P.No- 7, I.No-1.9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Cum266.0266.0165.41FalseNoneNoneFalseNoneFalse43999.060
280839590473NoneVOL-2 P.No- 41, I.No-8.3.2Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm336.3336.3227.96FalseNoneNoneFalseNoneFalse76662.9480
280835590473NoneVOL-1 P.No- 7, I.No-1.8 Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Cum474.0474.045.2FalseNoneNoneFalseNoneFalse21424.80
280842290473None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.3) 2.5 mm2 m42.042.0375.0FalseNoneNoneFalseNoneFalse15750.00
280839690473NoneVOL-2 P.No- 50, I.No-8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm101.0101.0378.97FalseNoneNoneFalseNoneFalse38275.970
280835690473NoneVOL-2 P.No- 14, I.No-6.8 Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Cum7969.07969.050.21FalseNoneNoneFalseNoneFalse400123.490
280842390473None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments (5/2.3.5) 6 mm2 m92.092.0150.0FalseNoneNoneFalseNoneFalse13800.00
280839790473NoneVOL-2 P.No- 42, I.No-8.5.2 Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm352.5352.5278.99FalseNoneNoneFalseNoneFalse98343.9750
280835790473NoneP.No-44, I.No-8.16a VOL-2 2023-24Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sqm1238.01238.09.07FalseNoneNoneFalseNoneFalse11228.660
280842490473None3.10.2Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.(9/3.10.2) 80/90mm Nos15.015.08.0FalseNoneNoneFalseNoneFalse120.00
280835890473NoneVOL-1 P.No- 18, I.No-2.11-aSupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings" Hour89457.089457.010.11FalseNoneNoneFalseNoneFalse904410.270
280842590473None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' cure, indicator ON/OFF, energy cross-3 with Short circuit breaking cappacity of 10K and complete wiring as required. Confirming to IEC 60898. (17/5.18.4)6-32 Amps DP Each739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
280839890473NoneVOL-2 P.No- 60, I.No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm" Sqm1156.51156.5115.35FalseNoneNoneFalseNoneFalse133402.2750
280839990473NoneVOL-2 P.No- 45, I.No-8.25 Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm138.4138.4378.97FalseNoneNoneFalseNoneFalse52449.4480
280842690473None5.19.7Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.( 18/5.19.7)II - Double Door 6 Way SP & N Each1791.01791.02.0FalseNoneNoneFalseNoneFalse3582.00
280835990473NoneP.No-77, I.No-11.5.1, PWD SR VOL-2 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Sqm4478.04478.06.5FalseNoneNoneFalseNoneFalse29107.00
280840090473NoneVOL-2 P.No- 45, I.No-8.27Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm53.553.5278.99FalseNoneNoneFalseNoneFalse14925.9650
280842790473None164.78Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. (Water Supply 164/45/ P430A) Job3750.03750.02.0FalseNoneNoneFalseNoneFalse7500.00
280836090473NoneP.No-79, I.No-11.11.1, PWD SR VOL-2Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kg148.0148.0889.0FalseNoneNoneFalseNoneFalse131572.00
280840190473NoneVOL-2 P.No- 45, I.No-8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm89.989.9278.99FalseNoneNoneFalseNoneFalse25081.2010
280842890473None11.3.2Supplying of . feet - LED PVC Square Batten .W with high quality diffuser with Life of 25000 burning hours & 70 percent lumen maintenance with CRI Morethan 80. Power Input: 220-240V at 50Hz & Power factor morethan 0.9 along with CE approved. 5 years Warranty against any manufacturing defect working under standard electrical condition LED light fighting 1 x4- 20/22 w (43/11.3.2)Nos690.0690.020.0FalseNoneNoneFalseNoneFalse13800.00
280836190473NoneVOL-2 P.No- 41, I.No-8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm255.0255.0258.89FalseNoneNoneFalseNoneFalse66016.950
280842990473None13.7.1Fixing all types and all capacities of fluorescent /False ceiling/spot light /CFL/LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076' twin twisted PVC insulated wires, required Nos of round blocks and clamps. (56/13.7.1)On wall / ceiling /Rafter / Girders Each112.0112.020.0FalseNoneNoneFalseNoneFalse2240.00
280840290473NoneVOL-2 P.No- 48, I.No-8.41 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm168.7168.752.01FalseNoneNoneFalseNoneFalse8774.0870
280836290473NoneVOL-2 P.No- 41, I.No-8.3.2Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm333.0333.0388.91FalseNoneNoneFalseNoneFalse129507.030
280836390473NoneVOL-2 P.No- 50, I.No-8.51 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sqm100.0100.0647.8FalseNoneNoneFalseNoneFalse64780.00
280843090473None6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200mm) Regular model (30/6.3.1) Nos2984.02984.09.0FalseNoneNoneFalseNoneFalse26856.00
280840390473NoneVOL-2 P.No- 1st addenda, I.No-13.48Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter m293.9293.98.0FalseNoneNoneFalseNoneFalse2351.20
280843190473None13.10Fixing a Ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook wisth fan regulator to the existing board together wisth wupplying and fixing 5amps. Ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. (57/13.10) Each171.0171.09.0FalseNoneNoneFalseNoneFalse1539.00
280840490473NoneVOL-2 P.No- 107, I.No-12.68.1Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 125x65x2.12mm" Nos55.655.63.0FalseNoneNoneFalseNoneFalse166.80
280836490473NoneVOL-2 P.No- 42, I.No-8.5.2 Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sqm349.0349.0234.25FalseNoneNoneFalseNoneFalse81753.250
280840590473NoneVOL-2 P.No- 107, I.No-12.68.3Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 75x47x1.7mm" Nos38.438.460.0FalseNoneNoneFalseNoneFalse2304.00
280836590473NoneVOL-2 P.No- 60, I.No-9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm" Sqm1145.01145.0245.47FalseNoneNoneFalseNoneFalse281063.150
280836690473NoneVOL-2 P.No- 63, I.No-9.23 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye,River Pink or equivalent. Sqm2466.02466.032.75FalseNoneNoneFalseNoneFalse80761.50
280840690473NoneVOL-2 P.No- 108, I.No-12.72Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : Nos82.882.823.0FalseNoneNoneFalseNoneFalse1904.40
280840790473NoneVOL-2 P.No- 108, I.No-12.73.1 Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 125mm" Nos44.444.42.0FalseNoneNoneFalseNoneFalse88.80
280836790473NoneVOL-2 P.No- 45, I.No-8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm137.0137.0647.6FalseNoneNoneFalseNoneFalse88721.20
280836890473NoneVOL-2 P.No- 45, I.No-8.27 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm53.053.0196.65FalseNoneNoneFalseNoneFalse10422.450
280840890473NoneVOL-2 P.No- 108, I.No-12.73.3Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 75mm" Nos31.331.320.0FalseNoneNoneFalseNoneFalse626.00
280836990473NoneVOL-2 P.No- 45, I.No-8.28Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm89.089.0196.65FalseNoneNoneFalseNoneFalse17501.850
280840990473NoneVOL-2 P.No- 107, I.No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Nos1062.51062.51.0FalseNoneNoneFalseNoneFalse1062.50
280837090473NoneVOL-2 P.No- 44, I.No-8.19.1Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. Sqm255.0255.018.16FalseNoneNoneFalseNoneFalse4630.80
280837190473NoneVOL-2 P.No- 48, I.No-8.41 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sqm167.0167.0104.02FalseNoneNoneFalseNoneFalse17371.340
280837290473NoneVOL-2 P.No- 75, I.No-11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fi in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Kgs113.0113.0234.17FalseNoneNoneFalseNoneFalse26461.210
280837390473NoneVOL-2 P.No- 1st addenda, I.No-13.48Providing & fixing on wall face unplasticised Rigid PVC rain water pipes confirming to IS : 13592 Type A, including jointing with seal seal ring conforming to IS : 5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter m291.0291.034.0FalseNoneNoneFalseNoneFalse9894.00
280837490473NoneVOL-2 P.No- 49, I.No-8.49Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. cm4.04.01000.0FalseNoneNoneFalseNoneFalse4000.00
280837590473NoneVOL-2 P.No- 107, I.No-12.68.1 Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 125x65x2.12mm Nos55.055.06.0FalseNoneNoneFalseNoneFalse330.00
280837690473NoneVOL-2 P.No- 107, I.No-12.68.3Providing and fixing ISI marked M.S. pressed butt hinges bright finishedwith necessary screws etc. 75x47x1.7mmNos38.038.0120.0FalseNoneNoneFalseNoneFalse4560.00
280837790473NoneVOL-2 P.No- 108, I.No-12.72Providing and fixing ISI marked oxidised M.S. tower bolt black finish,(Barrel type) with necessary screws etc. complete : Nos82.082.046.0FalseNoneNoneFalseNoneFalse3772.00
280837890473NoneVOL-2 P.No- 108, I.No-12.73.1 Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 125mm" Nos44.044.04.0FalseNoneNoneFalseNoneFalse176.00
280837990473NoneVOL-2 P.No- 108, I.No-12.73.3Providing and fixing ISI marked oxidised M.S. handles conforming toIS:4992 with necessary screws etc. complete : 75mm" Nos31.031.040.0FalseNoneNoneFalseNoneFalse1240.00
280838090473NoneVOL-2 P.No- 107, I.No-12.60Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Nos1052.01052.02.0FalseNoneNoneFalseNoneFalse2104.00
280838190473NoneP.No-175, I.No-17.3, PWD SR VOL-2Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 1 EACH1002.01002.01.41FalseNoneNoneFalseNoneFalse1412.820
280838290473NoneP.No-175, I.No-17.3, PWD SR VOL-2Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1192.01192.00.63FalseNoneNoneFalseNoneFalse750.960
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17089274590000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17089274590001NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of KarnatakaNone
17089274590001NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submissionNone
17089291690000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of e-Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17089291760000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17089291810000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17089291860000NoneNoneELIGIBILITYConditional tenders will not be acceptedNone
17089291910000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17089291970000NoneNoneELIGIBILITYThe cost of the Tender form shall not be refundableNone
17089292020000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing E - Procurement PortalNone
17089292080000NoneNoneELIGIBILITYContractors should be registered with KPWD Class III & Above RegistrationNone
17089292130000NoneNoneELIGIBILITYRoyalty on construction materials will be deducted as per prevailing Govt. ordersNone
17089292180000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.2007 and Government letter no PW/134/BMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17089292240000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejectedNone
17089292290000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the Executive Engineer reserves the right to verify the documents before approvalNone
17089292330000NoneNoneELIGIBILITYThe employer reserves the rights to Reject or accept any or all the tenders without assigning any reasonsNone
17089292400000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documents KW-3 K.P.W.D. and further orders there onNone
17089292450000NoneNoneELIGIBILITYIn the case of the death of the contractor after executing the agreement / commencement of the work, his legal heir, if he is an eligible registered contractor and he is willing to execute and complete the work at the accepted tender rates irrespective of the cost of the workNone
17089292510000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given below for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with Clause 25.5 & 29.1 of ITT and Clause 44 of the Conditions of ContractNone
17089292820000NoneNoneELIGIBILITYContractor should establish a fully functional laboratory at site at no extra cost in order to carry out all the required tests for the materials being used in the projectNone
17089292970000NoneNoneELIGIBILITYContractor should take all precautions to ensure that no damage is caused to the existing similar structures which have been constructed by other agencies during project execution. If any damage is caused, it has to be rectified at his own risk and costNone
17089293230000NoneNoneELIGIBILITYContractor should carryout additional test required to test the suitability of materials before using the same to the workNone
17089293320000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extentNone
17089293370000NoneNoneELIGIBILITYFormation levels and other data furnished are bare minimum the contractor should make all efforts to validate and to get additional data if required at his own costNone
17089293440000NoneNoneELIGIBILITYContractor should execute the project with least impact to the environmentNone
17089293500000NoneNoneELIGIBILITYContractor should adhere to HSE policy applicable for similar projects. Contractor to that extent should submit HSE document defining all the procedure including the policies before execution of the projectNone
17089293550000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the office of the Executive Engineer, PWD Division, Mandya during office hours on all working daysNone
17089293610000NoneNoneELIGIBILITYMaterials like Size stones, Bricks, Sand, Metal, steel, cement etc., required for the work shell be procured by the tenderer themselves and should got tested by the quality control authority before use on the work at their own costNone
17089293660000NoneNoneELIGIBILITYThe contractors assessed available tender capacity will be calculated as per the clause 3.6 of STD tender document AttachedNone
17089293710000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and conyence of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer - in - charge of this workNone
17089293780000NoneNoneELIGIBILITYWhen Structure constructed disputes arising on account of damages to the existing field / channels, bunds, Structure and other private properties, if any, has to be resolved by the contractor. All precautions should be taken by the contractor so that there are no damages to such public private propertiesNone
17089293830000NoneNoneELIGIBILITYContractor should take all precautionary measures to avoid any damage to the utilities during excavation as well as utility shifting. To that extent the contractor should indemnify the clientNone
17089293950000NoneNoneELIGIBILITYContractor should follow strictly the prevailing rules of labour actNone
17089294010000NoneNoneELIGIBILITYThe tenderer who quotes amount less than amount put to tender should pay difference amount in the form of FDR purchased through any nationalized bank payable at Mandya only in favor The Executive Engineer at the time of execution of the tender agreementNone
17089294060000NoneNoneELIGIBILITYThe EMD shall be submitted in favor of The Executive Engineer, PWD Division, Mandya through e-Banking for Rs.50000.00 rest of the EMD amount submitted in the form of Bank guarantee and produce the same at the time of opening the Technical bid without which liable for rejectionNone
17089294100000NoneNoneELIGIBILITYThe tenderer should maintain the executed works during the defective liability period for 1 yearNone
17089294150000NoneNoneELIGIBILITYNote:- If any postponement of receipt date of tender, the same will be published in the e-procurement portalNone
17089294200000NoneNoneELIGIBILITYAll the originals of uploaded documents in e-portal should be produced within 7 working days from the date of opening of Technical Bid at the Division Office, failing which the tender is liable for rejection. No separate communication will be made in this regard, failing which action will be taken as per tender conditions and registration rulesNone
17089294260000NoneNoneELIGIBILITYThe contractor who participates in tenders for more than one work for which tenders are invited in this IFT, the tenderer must fulfill all the conditions and criteria cumulatively for the participated worksNone
17089294310000NoneNoneELIGIBILITYLOC / K-form for the stipulated amount should be submitted in the format as prescribed in the bid document only. Otherwise tender is liable for rejectionNone
17089294380000NoneNoneELIGIBILITYThe returns submitted to the Income Tax Department. shall be uploaded or shall be produced at the time of verification of original documents at Division officeNone
17089294450000NoneNoneELIGIBILITYEstimate rates are excluding GST as per Common SR 2023-24 and prevailing GST (18% of amount put to tender) amount is kept is form of Lump sum in sanctioned estimate according to guidelines in Common SR. Therefore, amount put to tender and ECV amount are excluding GST. KPPP-PORTAL format has No options to add GST Separately at stage of Draft Tender Schedule Process for over all amount put to tender, tender has been inviting through an option with INCLUSIVE. But the item wise rates do not include GST. Hence, GST will be paid separately for the quoted amount accordinglyNone
17089294510000NoneNoneELIGIBILITYRegarding Appealing Aggrieved contractors may appeal to the prescribed (Appellant) authority within 30 days as per KTTP and appeal should be through e-proc only as per Govt.order No:pwd/572/CRM-2020(E) Bangalore DT.09-10-2020. The same will not be considered if appeal through LettersNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNone3.2 - To qualify for award of this contract, each Tenderer in its name should have in the last five years i.e. 2018-19 to 2022-23) (c) Executed in any one year, the following minimum quantities of work 1 Earthwork Excavation/Embankment : 242.00 Cum. 2 Cement Concrete(RCC/PCC) : 169.00 Cum 3 Reinforcement Steel : 1373.00 Kgs. 4. BBM / SSM / Solid block masonry / Non Modular bricks : 120.00 Cum 5. Plastering : 1258.00 Sqm 6. Flooring : 315.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone3.2 (b) Satisfactorily completed (at least 90% of the contract value), as prime contractor, at least one similar nature of work such as Construction of Building work of value not less than Rs.30.63 LakhsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNone3.6 - Tenderers who meet the above minimum qualifying criteria, will only be qualified of their available tender capacity is more than the total tender value. The available tender capacity is calculated as under Assessed available tender capacity (AxNx2.50 - B) where A Maximum value of civil engineering works executed in any one year during the last five years (updated to 2023-24 price level) taking into account the completed as well as works in progress N Number of years prescribed for completion of the works for which Tenders are invited. (N-0.50) B Value, at 2023-24 price level, of existing commitments and on-going works to be completed. during the next 6 monthsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Work done & balance work to be done certificate issued by an officer not below rank of EE/equivalent
NoneNoneNoneNone3.2 (a) Achieved in at least two financial years a minimum financial turnover (in all classes of Civil Engineering construction works only of Rs.61.25 Lakhs. (usually not less than two times the estimated annual payments under this contract)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNone3.3 - Each Tenderer should further demonstrate (b) Liquid assets and / or availability of credit facilities of not less than Rs.18.38 Lakhs. (Credit lines / letter of credit / certificates from banks for meeting the fund requirement etc.)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Registration CertificateTrueTechnical Bid
Profit & Loss Statement from Registered Chartered Accountant for last five financial yearsTrueTechnical Bid
Work done certificateTrueTechnical Bid
Line of credit / K-FormTrueTechnical Bid
Ongoing work detailsTrueTechnical Bid
Details of tenders already submittedTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone