createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710066792448
version6
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd1117000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose20-04-2024 17:30:00
tenderQueryClose15-04-2024 17:30:00
technicalBidOpen22-04-2024 11:00:00
publishedDate10-03-2024 17:54:17
publishedByPostKSHD_JDIR_VEG_JDOFF_BNG
publishedByUserKPE20304 - K DHANARAJ
bidValidityPeriod90
noOfCalls1
preBidMeetingDate21-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonDhanraj K
splitEmdRequiredYnTrue
emdBankGuarantee1017000.00
emdCash100000.00
bgValidityPeriod135
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448592678
tenderSupplierListNone
tenderSchedule
createdTs1710066792490
version6
createdDateNone
modifiedDateNone
tenderNumberKSHD/2023-24/BD/WORK_INDENT5
titleConstruction of Cold Storage of Capacity 2000 MT at Chawenahally Horticulture Farm, Malur Taluk, Kolar District ,Karnataka
descriptionConstruction of Cold Storage of Capacity 2000 MT at Chawenahally Horticulture Farm, Malur Taluk, Kolar District, Karnataka
categoryWORKS
categoryTextWorks
ecv100731700.68
deptNameKarnataka State Horticulture Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5201
locationNameKSHD Joint Director Office Vegetables Bengaluru
provisionalAmount101706000.0
groupOverheadTotal15365852.65
fileNumberDH/JDH/VEG/SADH/PHM/AHO-2/31/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17100667920000NoneNoneBuildingsCIVIL WORK45455851.77
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
297870898795NoneKSHD1COLD STORAGE - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In all kinds of soils Depth upto 3 mCUBIC METER102.0102.0359.7FalseNoneNoneFalseNoneFalse36689.40
297870998795NoneKSHD2Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In ordinary/soft rock without blasting upto 1.5 m depthCUBIC METER363.0363.0226.35FalseNoneNoneFalseNoneFalse82165.050
297871098795NoneKSHD3Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In ordinary/soft rock without blasting Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER425.0425.0298.27FalseNoneNoneFalseNoneFalse126764.750
297871198795NoneKSHD4Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)In Hard Rock ( requiring blasting) Depth upto 1.50mCUBIC METER554.0554.010.0FalseNoneNoneFalseNoneFalse5540.00
297871298795NoneKSHD5Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER623.0623.010.0FalseNoneNoneFalseNoneFalse6230.00
297871398795NoneKSHD6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.CUBIC METER266.0266.040.11FalseNoneNoneFalseNoneFalse10669.260
297871498795NoneKSHD7Filling available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.CUBIC METER474.0474.0298.01FalseNoneNoneFalseNoneFalse141256.740
297871598795NoneKSHD8Providing and injecting chemical emulsion for Pre-constructional Anti-TeRmtrtrite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm118.0118.0749.56FalseNoneNoneFalseNoneFalse88448.080
297871698795NoneKSHD9Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.CUBIC METER2682.02682.0115.75FalseNoneNoneFalseNoneFalse310441.50
297871798795NoneKSHD10Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5338.05338.010.0FalseNoneNoneFalseNoneFalse53380.00
297871898795NoneKSHD11Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates.CUBIC METER5664.05664.0151.72FalseNoneNoneFalseNoneFalse859342.080
297871998795NoneKSHD12Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost including Centering and shuttering but excluding steel reinforcement)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCUBIC METER6217.06217.010.0FalseNoneNoneFalseNoneFalse62170.00
297872098795NoneKSHD13Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost including Centering and shuttering but excluding steel reinforcement) Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Flooring WorksCUBIC METER6480.06480.064.14FalseNoneNoneFalseNoneFalse415627.20
297872198795NoneKSHD14Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FlooringCUBIC METER6605.06605.010.0FalseNoneNoneFalseNoneFalse66050.00
297872298795NoneKSHD15The concrete finished with shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).Sqm200.0200.0728.0FalseNoneNoneFalseNoneFalse145600.00
297872398795NoneKSHD16Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing and Lift wall.CUBIC METER7281.367281.36193.7965FalseNoneNoneFalseNoneFalse1411102.083240
297872498795NoneKSHD17Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column/Pedastrals and Lift wall.CUBIC METER11461.411461.431.46FalseNoneNoneFalseNoneFalse360575.6440
297872598795NoneKSHD18Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PLINTH BEAM.CUBIC METER10113.010113.049.14FalseNoneNoneFalseNoneFalse496952.820
297872698795NoneKSHD19Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor Column.CUBIC METER11911.911911.983.27FalseNoneNoneFalseNoneFalse991903.9130
297872798795NoneKSHD20Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor Roof BeamCUBIC METER11211.211211.2122.97FalseNoneNoneFalseNoneFalse1378641.2640
297872898795NoneKSHD21Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor Roof Slab, Staircase SlabCUBIC METER10510.510510.518.77FalseNoneNoneFalseNoneFalse197282.0850
297872998795NoneKSHD22Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor SunshadeCUBIC METER10610.1510610.151.18FalseNoneNoneFalseNoneFalse12519.9770
297873098795NoneKSHD23Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)First Floor ColumnCUBIC METER12031.0212031.0271.71FalseNoneNoneFalseNoneFalse862744.44420
297873198795NoneKSHD24Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)First Floor Roof BeamCUBIC METER11323.3111323.31122.97FalseNoneNoneFalseNoneFalse1392427.43070
297873298795NoneKSHD25Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)First Floor Roof Slab,Staircase slab.CUBIC METER10615.6110615.6118.86FalseNoneNoneFalseNoneFalse200210.40460
297873398795NoneKSHD26Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) First Floor SunshadeCUBIC METER10261.7510261.751.65FalseNoneNoneFalseNoneFalse16931.88750
297873498795NoneKSHD27Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)Second Floor ColumnCUBIC METER12151.3312151.3373.96FalseNoneNoneFalseNoneFalse898712.36680
297873598795NoneKSHD28Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)Second Floor Roof BeamCUBIC METER11436.5511436.5554.45FalseNoneNoneFalseNoneFalse622720.14750
297873698795NoneKSHD29Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)Second Floor Roof SlabCUBIC METER10721.7610721.764.0FalseNoneNoneFalseNoneFalse42887.040
297873798795NoneKSHD30Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Second Floor SunshadeCUBIC METER10364.3710364.370.12FalseNoneNoneFalseNoneFalse1243.72440
297873898795NoneKSHD31Providing and placing in position precast reinforced cement concrete waffle units, square or rectangular, as per design and shape for floors and roofs in CUBIC METER0 Grade Concrete, including flush or deep ruled pointing at joints in Cement mortar 1:2 (1 Cement : 2 Fine sand), making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, foRmtrtr work in precasting, handling, hoisting, centering and erection complete for all floor levels but, excluding the cost of reinforcement.CUBIC METER26610.1426610.1499.39FalseNoneNoneFalseNoneFalse2644781.81460
297873998795NoneKSHD32Providing TheRmtrtro-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg96.096.0195200.8FalseNoneNoneFalseNoneFalse18739276.80
297874098795NoneKSHD33Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7978.07978.052.15FalseNoneNoneFalseNoneFalse416052.70
297874198795NoneKSHD34Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7969.07969.0302.98FalseNoneNoneFalseNoneFalse2414447.620
297874298795NoneKSHD35Providing Brick work with Non Modular fly ash bricks confoRmtrtring to IS:12894, class designation 5.0 average compressive strength in super structure above plinth level up to floor I level in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7627.07627.010.0FalseNoneNoneFalseNoneFalse76270.00
297874398795NoneKSHD36Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workSqm1060.01060.0349.19FalseNoneNoneFalseNoneFalse370141.40
297874498795NoneKSHD37Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-chargeSqm312.0312.01983.8FalseNoneNoneFalseNoneFalse618945.60
297874598795NoneKSHD38Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm354.0354.01719.63FalseNoneNoneFalseNoneFalse608749.020
297874698795NoneKSHD39Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer-in-Charge.Sqm58.058.0199.5043FalseNoneNoneFalseNoneFalse11571.24940
297874798795NoneKSHD40Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for paymentRmtr38.038.0150.0FalseNoneNoneFalseNoneFalse5700.00
297874898795NoneKSHD41FoRmtrtring groove of unifoRmtrtr size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m52.052.050.0FalseNoneNoneFalseNoneFalse2600.00
297874998795NoneKSHD42Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.Sqm451.0451.0227.98FalseNoneNoneFalseNoneFalse102818.980
297875098795NoneKSHD43Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm174.0174.01719.63FalseNoneNoneFalseNoneFalse299215.620
297875198795NoneKSHD44Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm158.0158.01983.8FalseNoneNoneFalseNoneFalse313440.40
297875298795NoneKSHD45Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4242.04242.010.0FalseNoneNoneFalseNoneFalse42420.00
297875398795NoneKSHD46Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confoRmtrtring to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2633.02633.03.75FalseNoneNoneFalseNoneFalse9873.750
297875498795NoneKSHD47Extra for providing mechanical device chain and crank operation for operating rolling shutters: including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge.Sqm987.0987.03.75FalseNoneNoneFalseNoneFalse3701.250
297875598795NoneKSHD48Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Each24686.024686.01.0FalseNoneNoneFalseNoneFalse24686.00
297875698795NoneKSHD49Providing and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg106.0106.01000.0FalseNoneNoneFalseNoneFalse106000.00
297875798795NoneKSHD50Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.Kg113.0113.01000.0FalseNoneNoneFalseNoneFalse113000.00
297875898795NoneKSHD51Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge.Kg136.0136.02500.0FalseNoneNoneFalseNoneFalse340000.00
297875998795NoneKSHD52Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @0.75 ltr/10 Sqm of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm138.0138.020.0FalseNoneNoneFalseNoneFalse2760.00
297876098795NoneKSHD53Providing, fabricating, transporting and erecting at all heights, depths and locations steel structures such as columns, beams, trusses, portals, bracings, purlins, gantry girders, ladders, stair cases , steps, castellated girders, latticed girders, monorails, platfoRmtrtrs, brackets, rails, walkways, cleats, gutters, separators, pipes, anchor bolt and sleeves, plate girders etc. using joists, angles, channels, flats, rounds, plates etc. cutting to required size, bending, riveting, bolting and/or welding of joints, fixing in line and level with temporary staging, including one coat of red oxide primer and two coats of synthetic enamel paint The rate should also include supply of labour, all consumables and etc. required for proper completion of the work. PEB StructureMT105932.0105932.020.83FalseNoneNoneFalseNoneFalse2206563.560
297876198795NoneKSHD54Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g/ SqmSqm879.0879.0872.71FalseNoneNoneFalseNoneFalse767112.090
297876298795NoneKSHD55Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of unifoRmtrtr pigmentation and thickness without air pockets and shall confoRmtrtr to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5"" or 4.2"" or 6"") or step-down (2"" or 3"" or 6"" ) as specifiedSqm1058.01058.020.0FalseNoneNoneFalseNoneFalse21160.00
297876398795NoneKSHD56Providing & fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 0.63 mm thick with zinc coating not less than 275 g/Sqmm639.0639.030.7FalseNoneNoneFalseNoneFalse19617.30
297876498795NoneKSHD57Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/Sqm)m645.0645.061.4FalseNoneNoneFalseNoneFalse39603.00
297876598795NoneKSHD58Supply and installation of wind driven turbine ventilators (mill finish) throat width 600mm, the turbine head and variable angle elbow is manufactured out of aluminum alloy having 0.71mm thick vanes, the shaft is made out of stainless steel, and the installation using stainless steel hardware and EPDM rubber washers and with double row ball-bearing system. SPEC: Rotation: Twin Sealed 6203ZZ/Twin Sealed 6201ZZ bearings with self lubricating to ensure frictionless rotation even at lowest wind velocity, 42 Vanes, Base Ring MOC (Mounting Ring): SS, Top plate MOC : SS 0.8mm thk, Bearing Type: SKF - 6001 ZZ & 6003 ZZ PeRmtrtranently Lubricated & Sealed, Rivets: Aluminum Alloy with Washer, FRP base: 2 mm thick clear 1.020 mtr wide and 1.65 mtr long matching your sheet profile, Size: Turbine dia- 28" , Throat dia- 24" , Height18". (Make: Hurricane, SVS ventillators, Horne)Each7500.07500.010.0FalseNoneNoneFalseNoneFalse75000.00
297876698795NoneKSHD59Supplying PVC ringtite pipes confoRmtrtring to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3m441.0441.0120.0FalseNoneNoneFalseNoneFalse52920.00
297876798795NoneKSHD60Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110mm dia PVC BendEach492.0492.08.0FalseNoneNoneFalseNoneFalse3936.00
297876898795NoneKSHD61Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110mm dia PVC ElbowsEach302.0302.08.0FalseNoneNoneFalseNoneFalse2416.00
297876998795NoneKSHD62TECHNICIAN SHED - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In all kinds of soils Depth upto 3 mCUBIC METER102.0102.023.52FalseNoneNoneFalseNoneFalse2399.040
297877098795NoneKSHD63Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In ordinary/soft rock without blasting upto 1.5 m depthCUBIC METER363.0363.028.55FalseNoneNoneFalseNoneFalse10363.650
297877198795NoneKSHD64Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER425.0425.016.46FalseNoneNoneFalseNoneFalse6995.50
297877298795NoneKSHD65Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)In Hard Rock ( requiring blasting) Depth upto 1.50mCUBIC METER554.0554.010.0FalseNoneNoneFalseNoneFalse5540.00
297877398795NoneKSHD66Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER623.0623.010.0FalseNoneNoneFalseNoneFalse6230.00
297877498795NoneKSHD67Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.CUBIC METER266.0266.010.17FalseNoneNoneFalseNoneFalse2705.220
297877598795NoneKSHD68Filling available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling,water,all materials,usage& all other appurtenaces required to complete the work.CUBIC METER474.0474.030.31FalseNoneNoneFalseNoneFalse14366.940
297877698795NoneKSHD69Providing and injecting chemical emulsion for Pre constructional Anti-TeRmtrtrite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm118.0118.080.6748FalseNoneNoneFalseNoneFalse9519.62640
297877798795NoneKSHD70Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.CUBIC METER2682.02682.013.8933FalseNoneNoneFalseNoneFalse37261.83060
297877898795NoneKSHD71Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5338.05338.010.0FalseNoneNoneFalseNoneFalse53380.00
297877998795NoneKSHD72Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5664.05664.013.8933FalseNoneNoneFalseNoneFalse78691.65120
297878098795NoneKSHD73Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost including Centering and shuttering but excluding steel reinforcement)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCUBIC METER6217.06217.010.0FalseNoneNoneFalseNoneFalse62170.00
297878198795NoneKSHD74Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost including Centering and shuttering but excluding steel reinforcement) Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Flooring WorksCUBIC METER6480.06480.07.41FalseNoneNoneFalseNoneFalse48016.80
297878298795NoneKSHD75Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCUBIC METER6605.06605.010.0FalseNoneNoneFalseNoneFalse66050.00
297878398795NoneKSHD76The concrete finished with shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge.Sqm200.0200.080.6748FalseNoneNoneFalseNoneFalse16134.960
297878498795NoneKSHD77Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FootingCUBIC METER7281.367281.367.06FalseNoneNoneFalseNoneFalse51406.40160
297878598795NoneKSHD78Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column/Pedastrals Basement to ground floorCUBIC METER11461.411461.41.4256FalseNoneNoneFalseNoneFalse16339.371840
297878698795NoneKSHD79Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth BeamCUBIC METER10113.010113.06.91FalseNoneNoneFalseNoneFalse69880.830
297878798795NoneKSHD80Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor ColumnSqm11911.911911.93.4FalseNoneNoneFalseNoneFalse40500.460
297878898795NoneKSHD81Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column Ground Floor Roof Beam & Lintel BeamSqm11211.211211.25.73FalseNoneNoneFalseNoneFalse64240.1760
297878998795NoneKSHD82Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column Ground Floor Roof SlabCUBIC METER10510.510510.57.41FalseNoneNoneFalseNoneFalse77882.8050
297879098795NoneKSHD83Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtrtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Ground Floor Column Ground Floor SunshadeCUBIC METER10160.1510160.150.7038FalseNoneNoneFalseNoneFalse7150.713570
297879198795NoneKSHD84Providing and placing in position precast reinforced cement concrete waffle units, square or rectangular, as per design and shape for floors and roofs in CUBIC METER0 Grade Concrete, including flush or deep ruled pointing at joints in Cement mortar 1:2 (1 Cement : 2 Fine sand), making necessary holes of required sizes for carrying through service lines etc., providing steel hooks for lifting etc, foRmtrtr work in precasting, handling, hoisting, centering and erection complete for all floor levels but, excluding the cost of reinforcement.CUBIC METER26610.026610.05.0FalseNoneNoneFalseNoneFalse133050.00
297879298795NoneKSHD85Providing TheRmtrtro-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg96.096.05519.41FalseNoneNoneFalseNoneFalse529863.360
297879398795NoneKSHD86Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7978.07978.05.99FalseNoneNoneFalseNoneFalse47788.220
297879498795NoneKSHD87Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7969.07969.026.95FalseNoneNoneFalseNoneFalse214764.550
297879598795NoneKSHD88Providing Brick work with Non Modular fly ash bricks confoRmtrtring to IS:12894, class designation 5.0 average compressive strength in super structure above plinth level up to floor I level in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7627.07627.010.0FalseNoneNoneFalseNoneFalse76270.00
297879698795NoneKSHD89Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workSqm1060.01060.035.658FalseNoneNoneFalseNoneFalse37797.480
297879798795NoneKSHD90Half brick masonry with Non Modular fly ash bricks of class designation 5.0, confoRmtrtring to IS :12894, in super structure above plinth and upto floor I level cement mortar 1 : 3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of workSqm988.0988.010.0FalseNoneNoneFalseNoneFalse9880.00
297879898795NoneKSHD91Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm323.0323.041.4FalseNoneNoneFalseNoneFalse13372.20
297879998795NoneKSHD92Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm312.0312.0138.53FalseNoneNoneFalseNoneFalse43221.360
297880098795NoneKSHD93Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm349.0349.09.9984FalseNoneNoneFalseNoneFalse3489.44160
297880198795NoneKSHD94Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm354.0354.0185.5857FalseNoneNoneFalseNoneFalse65697.33780
297880298795NoneKSHD95Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for paymentRmtr38.038.0500.0FalseNoneNoneFalseNoneFalse19000.00
297880398795NoneKSHD96FoRmtrtring groove of unifoRmtrtr size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m52.052.0100.0FalseNoneNoneFalseNoneFalse5200.00
297880498795NoneKSHD97Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.Sqm451.0451.010.0FalseNoneNoneFalseNoneFalse4510.00
297880598795NoneKSHD98Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer- in-charge.Sqm26.026.041.4FalseNoneNoneFalseNoneFalse1076.40
297880698795NoneKSHD99Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm174.0174.0185.5857FalseNoneNoneFalseNoneFalse32291.91180
297880798795NoneKSHD100Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm156.0156.0138.53FalseNoneNoneFalseNoneFalse21610.680
297880898795NoneKSHD101Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm100.0100.0138.53FalseNoneNoneFalseNoneFalse13853.00
297880998795NoneKSHD102Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confoRmtrtring to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1238.01238.035.26FalseNoneNoneFalseNoneFalse43651.880
297881098795NoneKSHD103Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600x600 mmSqm209.0209.035.26FalseNoneNoneFalseNoneFalse7369.340
297881198795NoneKSHD104Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm2466.02466.036.37FalseNoneNoneFalseNoneFalse89688.420
297881298795NoneKSHD105Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with ce- ment mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.Sqm4279.04279.023.622FalseNoneNoneFalseNoneFalse101078.5380
297881398795NoneKSHD106Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality confoRmtrtring to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including pointing the joints with white cement and matching pigments etc., complete.Sqm889.0889.08.3468FalseNoneNoneFalseNoneFalse7420.30520
297881498795NoneKSHD107Providing and fixing 1st quality ceramic glazed wall tiles confoRmtrtring to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per Sqm, including pointing in white cement mixed with pigment of matching shade complete.Sqm1106.01106.043.473FalseNoneNoneFalseNoneFalse48081.1380
297881598795NoneKSHD108Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per Sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per Sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm817.0817.053.99FalseNoneNoneFalseNoneFalse44109.830
297881698795NoneKSHD109Providing & fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.Sqm565.0565.049.3956FalseNoneNoneFalseNoneFalse27908.5140
297881798795NoneKSHD110Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.CUBIC METER2017.02017.04.94FalseNoneNoneFalseNoneFalse9963.980
297881898795NoneKSHD111Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.CUBIC METER98815.098815.00.23FalseNoneNoneFalseNoneFalse22727.450
297881998795NoneKSHD112Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos.1016.01016.07.0FalseNoneNoneFalseNoneFalse7112.00
297882098795NoneKSHD113Providing and fixing cramps of required size & shape in RCC/ CC / Brick masonry backing with cement mortar 1:2 ( 1 cement :2 coarse sand), including drilling necessary hole in stones and embedding the cramp in the hole (fastener to be paid separately). Stainless steel crampsKg529.0529.08.4FalseNoneNoneFalseNoneFalse4443.60
297882198795NoneKSHD114Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmEach60.060.042.0FalseNoneNoneFalseNoneFalse2520.00
297882298795NoneKSHD115Providing and fixing flush door shutter made out of solid core block board type, well seasoned, chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol foRmtraldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. 35 mm thick both side commercialSqm3322.03322.05.67FalseNoneNoneFalseNoneFalse18835.740
297882398795NoneKSHD116Providing & fixing fiber glass reinforced plastic (FRP) Door frame of cross section 90mm x 45mm having single rebate of 32mm x 15mm to recieve shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyster resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The fram,e shall be covered with fiber glass foRmtr all sides. MS stay shall be provided at the bottomRmtr643.0643.019.6FalseNoneNoneFalseNoneFalse12602.80
297882498795NoneKSHD117Providing & fixing to existing door frames, 30mm thick Glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacture made with fire retardant grade unsaturated polyster resin, moulded to 3mm thick FRP Laminate for foRmtring hollow railsand styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP Laminate for panels confoRmtring to IS 14856 Including fixing to framesSqm3204.03204.05.88FalseNoneNoneFalseNoneFalse18839.520
297882598795NoneKSHD118Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1052.01052.03.0FalseNoneNoneFalseNoneFalse3156.00
297882698795NoneKSHD119Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos990.0990.03.0FalseNoneNoneFalseNoneFalse2970.00
297882798795NoneKSHD120Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos237.0237.06.0FalseNoneNoneFalseNoneFalse1422.00
297882898795NoneKSHD121Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mmEach249.0249.06.0FalseNoneNoneFalseNoneFalse1494.00
297882998795NoneKSHD122Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 100 mm with plate 150x32 mmEach231.0231.06.0FalseNoneNoneFalseNoneFalse1386.00
297883098795NoneKSHD123Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos130.0130.014.0FalseNoneNoneFalseNoneFalse1820.00
297883198795NoneKSHD124Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x70x4 mm (ordinary type)Nos184.0184.018.0FalseNoneNoneFalseNoneFalse3312.00
297883298795NoneKSHD125Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 100x70x4 mm (ordinary type)Nos140.0140.012.0FalseNoneNoneFalseNoneFalse1680.00
297883398795NoneKSHD126Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos120.0120.07.0FalseNoneNoneFalseNoneFalse840.00
297883498795NoneKSHD127Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1114.01114.07.0FalseNoneNoneFalseNoneFalse7798.00
297883598795NoneKSHD128Providing and fixing chromium plated brass curtain rod with ISI mark having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm diam653.0653.06.0FalseNoneNoneFalseNoneFalse3918.00
297883698795NoneKSHD129Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(TheRmtro Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size - 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6734.06734.06.6FalseNoneNoneFalseNoneFalse44444.40
297883798795NoneKSHD130Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(TheRmtro Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5719.05719.00.36FalseNoneNoneFalseNoneFalse2058.840
297883898795NoneKSHD131Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kg183.0183.0110.0FalseNoneNoneFalseNoneFalse20130.00
297883998795NoneKSHD132Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg565.0565.0200.0FalseNoneNoneFalseNoneFalse113000.00
297884098795NoneKSHD133Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4242.04242.02.0FalseNoneNoneFalseNoneFalse8484.00
297884198795NoneKSHD134Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength confoRmtring to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2633.02633.06.048FalseNoneNoneFalseNoneFalse15924.3840
297884298795NoneKSHD135Extra for providing mechanical device chain and crank operation for operating rolling shutters: including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge.Sqm987.0987.06.048FalseNoneNoneFalseNoneFalse5969.3760
297884398795NoneKSHD136Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Each24686.024686.01.0FalseNoneNoneFalseNoneFalse24686.00
297884498795NoneKSHD137Providing and fixing double action hydraulic floor spring of approved brand manufacture confoRmtring to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge: With stainless steel cover plate minimum 1.25 mm thickness including cost of materials, labour, usage charges of machinery complete as per specifications.Each2619.02619.07.0FalseNoneNoneFalseNoneFalse18333.00
297884598795NoneKSHD138Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg113.0113.01183.625FalseNoneNoneFalseNoneFalse133749.6250
297884698795NoneKSHD139Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @0.75 ltr/10 Sqm of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm138.0138.05.67FalseNoneNoneFalseNoneFalse782.460
297884798795NoneKSHD140Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge.Sqm50.050.0118.72FalseNoneNoneFalseNoneFalse5936.00
297884898795NoneKSHD141Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm115.0115.0118.72FalseNoneNoneFalseNoneFalse13652.80
297884998795NoneKSHD142Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge.0.63 mm thick with zinc coating not less than 275 g/ SqmSqm879.0879.051.51FalseNoneNoneFalseNoneFalse45277.290
297885098795NoneKSHD143Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g/Sqm)m645.0645.04.25FalseNoneNoneFalseNoneFalse2741.250
297885198795NoneKSHD144Providing and fixing on wall face unplasticised Rigid PVC rain water pipes confoRmtring to IS : 13592 Type A, including jointing with seal ring confoRmtring to IS : 5382, leaving 10 mm gap for theRmtral expansion, (i) Single socketed pipes 100 mm diameterm291.0291.050.0FalseNoneNoneFalseNoneFalse14550.00
297885298795NoneKSHD145Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia confoRmtring to IS : 13592 Type A, including jointing with seal ring confoRmtring to IS : 5382, leaving 10 mm gap for theRmtral expansion, (i) Single socketed pipes.m568.0568.0100.0FalseNoneNoneFalseNoneFalse56800.00
297885398795NoneKSHD146Water Supply - Providing and fixing C.P. brass long body bib cock of approved quality confoRmtring to IS standards and weighing not less than 690 g.Nos.846.0846.03.0FalseNoneNoneFalseNoneFalse2538.00
297885498795NoneKSHD147Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make confoRmtring to IS:8931.Nos.725.0725.04.0FalseNoneNoneFalseNoneFalse2900.00
297885598795NoneKSHD148Providing and fixing gun metal non- return valve of approved quality (screwed end) : 32 mm nominal bore - VerticalNos.925.0925.01.0FalseNoneNoneFalseNoneFalse925.00
297885698795NoneKSHD149Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore - VerticalNos.1225.01225.01.0FalseNoneNoneFalseNoneFalse1225.00
297885798795NoneKSHD150Supplying PVC ringtite pipes confoRmtring to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 25mm dia, 10 kg/sqcm & class 5Rmtr48.048.010.0FalseNoneNoneFalseNoneFalse480.00
297885898795NoneKSHD151Supplying PVC ringtite pipes confoRmtring to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 32mm dia, 10 kg/sqcm & class 5Rmtr67.067.010.0FalseNoneNoneFalseNoneFalse670.00
297885998795NoneKSHD152Supplying PVC ringtite pipes confoRmtring to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3Rmtr220.0220.06.0FalseNoneNoneFalseNoneFalse1320.00
297886098795NoneKSHD153Supplying PVC ringtite pipes confoRmtring to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3Rmtr411.0411.06.0FalseNoneNoneFalseNoneFalse2466.00
297886198795NoneKSHD154Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete. 25mm dia PVC couplersEach12.012.04.0FalseNoneNoneFalseNoneFalse48.00
297886298795NoneKSHD155Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete. 32mm dia PVC couplersEach16.016.04.0FalseNoneNoneFalseNoneFalse64.00
297886398795NoneKSHD156Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25mm dia PVC ElbowsEach16.016.04.0FalseNoneNoneFalseNoneFalse64.00
297886498795NoneKSHD157Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 32mm dia PVC ElbowsEach21.021.04.0FalseNoneNoneFalseNoneFalse84.00
297886598795NoneKSHD158Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25mm dia PVC BendEach24.024.03.0FalseNoneNoneFalseNoneFalse72.00
297886698795NoneKSHD159Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 32mm dia PVC BendEach36.036.03.0FalseNoneNoneFalseNoneFalse108.00
297886798795NoneKSHD160Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 25mm dia PVC TeeEach21.021.02.0FalseNoneNoneFalseNoneFalse42.00
297886898795NoneKSHD161Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 32mm dia PVC TeeEach32.032.02.0FalseNoneNoneFalseNoneFalse64.00
297886998795NoneKSHD162Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 110mm dia PVC TeeEach251.0251.02.0FalseNoneNoneFalseNoneFalse502.00
297887098795NoneKSHD163Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75mm dia PVC TeeEach117.0117.02.0FalseNoneNoneFalseNoneFalse234.00
297887198795NoneKSHD164Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 110mm DiaRmtr505.0505.010.0FalseNoneNoneFalseNoneFalse5050.00
297887298795NoneKSHD165Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 75mm Dia PVC PipeRmtr264.0264.010.0FalseNoneNoneFalseNoneFalse2640.00
297887398795NoneKSHD166Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), confoRmtring to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach5977.05977.03.0FalseNoneNoneFalseNoneFalse17931.00
297887498795NoneKSHD167Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach2561.02561.02.0FalseNoneNoneFalseNoneFalse5122.00
297887598795NoneKSHD168Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach4121.04121.01.0FalseNoneNoneFalseNoneFalse4121.00
297887698795NoneKSHD169Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1220.01220.02.0FalseNoneNoneFalseNoneFalse2440.00
297887798795NoneKSHD170Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.Each145.0145.02.0FalseNoneNoneFalseNoneFalse290.00
297887898795NoneKSHD171450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 g.Each478.0478.03.0FalseNoneNoneFalseNoneFalse1434.00
297887998795NoneKSHD172Providing and fixing 100 mm sand cast Iron grating for gully trap.Each47.047.02.0FalseNoneNoneFalseNoneFalse94.00
297888098795NoneKSHD173Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Each5642.05642.02.0FalseNoneNoneFalseNoneFalse11284.00
297888198795NoneKSHD174SECURITY BLOCK - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In all kinds of soils Depth upto 3 mCUBIC METER102.0102.05.29FalseNoneNoneFalseNoneFalse539.580
297888298795NoneKSHD175Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth\CUBIC METER363.0363.04.18FalseNoneNoneFalseNoneFalse1517.340
297888398795NoneKSHD176Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER425.0425.03.7FalseNoneNoneFalseNoneFalse1572.50
297888498795NoneKSHD177Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)In Hard Rock ( requiring blasting) Depth upto 1.50mCUBIC METER554.0554.010.0FalseNoneNoneFalseNoneFalse5540.00
297888598795NoneKSHD178Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER623.0623.010.0FalseNoneNoneFalseNoneFalse6230.00
297888698795NoneKSHD179Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.CUBIC METER266.0266.010.24FalseNoneNoneFalseNoneFalse2723.840
297888798795NoneKSHD180Providing and injecting chemical emulsion for Pre-constructional Anti-TeRmtrite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm118.0118.011.9716FalseNoneNoneFalseNoneFalse1412.64880
297888898795NoneKSHD181Providing and Filling in foundation with granite / trap broken metal 100mm. And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.CUBIC METER2682.02682.01.95FalseNoneNoneFalseNoneFalse5229.90
297888998795NoneKSHD182Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Mix 1:5:10 Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5338.05338.010.0FalseNoneNoneFalseNoneFalse53380.00
297889098795NoneKSHD183Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement)Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5664.05664.01.95FalseNoneNoneFalseNoneFalse11044.80
297889198795NoneKSHD184Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost including Centering and shuttering but excluding steel reinforcement)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCUBIC METER6217.06217.010.0FalseNoneNoneFalseNoneFalse62170.00
297889298795NoneKSHD185Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCUBIC METER6605.06605.010.0FalseNoneNoneFalseNoneFalse66050.00
297889398795NoneKSHD186Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & foRmtrwork to be paid separately)CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FootingCUBIC METER7281.07281.00.85FalseNoneNoneFalseNoneFalse6188.850
297889498795NoneKSHD187Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & foRmtrwork to be paid separately)CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Column/PedastralsCUBIC METER11461.411461.40.31FalseNoneNoneFalseNoneFalse3553.0340
297889598795NoneKSHD188Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & foRmtrwork to be paid separately)CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth BeamCUBIC METER10510.510510.50.68FalseNoneNoneFalseNoneFalse7147.140
297889698795NoneKSHD189Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor ColumnCUBIC METER11911.911911.90.68FalseNoneNoneFalseNoneFalse8100.0920
297889798795NoneKSHD190Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor Roof Beam & Lintel.CUBIC METER11211.211211.20.76FalseNoneNoneFalseNoneFalse8520.5120
297889898795NoneKSHD191Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor Roof Slab and StaircaseCUBIC METER10510.510510.52.47FalseNoneNoneFalseNoneFalse25960.9350
297889998795NoneKSHD192Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost including Centering and shuttering but excluding steel reinforcement) Ground Floor SunshadeCUBIC METER10610.1510610.150.97FalseNoneNoneFalseNoneFalse10291.84550
297890098795NoneKSHD193Providing TheRmtro-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg96.096.0922.06FalseNoneNoneFalseNoneFalse88517.760
297890198795NoneKSHD194Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7978.07978.00.83FalseNoneNoneFalseNoneFalse6621.740
297890298795NoneKSHD195Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.CUBIC METER7969.07969.04.7FalseNoneNoneFalseNoneFalse37454.30
297890398795NoneKSHD196Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm323.0323.035.92FalseNoneNoneFalseNoneFalse11602.160
297890498795NoneKSHD197Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm312.0312.024.87FalseNoneNoneFalseNoneFalse7759.440
297890598795NoneKSHD198Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm354.0354.034.61FalseNoneNoneFalseNoneFalse12251.940
297890698795NoneKSHD199Providing and fixing suitable plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for paymentRmtr38.038.0100.0FalseNoneNoneFalseNoneFalse3800.00
297890798795NoneKSHD200FoRmtring groove of unifoRmtr size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 10mm to 15 mm wide and 8 mm deep groove.m52.052.050.0FalseNoneNoneFalseNoneFalse2600.00
297890898795NoneKSHD201Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.Sqm451.0451.01.0FalseNoneNoneFalseNoneFalse451.00
297890998795NoneKSHD202Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer- in-charge.Sqm26.026.035.92FalseNoneNoneFalseNoneFalse933.920
297891098795NoneKSHD203Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm174.0174.034.61FalseNoneNoneFalseNoneFalse6022.140
297891198795NoneKSHD204Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)Sqm158.0158.024.87FalseNoneNoneFalseNoneFalse3929.460
297891298795NoneKSHD205Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and confoRmtring to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm.Sqm1238.01238.09.0FalseNoneNoneFalseNoneFalse11142.00
297891398795NoneKSHD206Providing & fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2% integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete.Sqm565.0565.016.435FalseNoneNoneFalseNoneFalse9285.7750
297891498795NoneKSHD207Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.CUBIC METER2017.02017.01.6435FalseNoneNoneFalseNoneFalse3314.93950
297891598795NoneKSHD208Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @0.75 ltr/10 Sqm of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm138.0138.03.78FalseNoneNoneFalseNoneFalse521.640
297891698795NoneKSHD209Providing and laying flooring and steps machine cut granite slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with ce- ment mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications.Sqm4279.04279.01.08FalseNoneNoneFalseNoneFalse4621.320
297891798795NoneKSHD210Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(TheRmtro Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size - 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5390.05390.010.8FalseNoneNoneFalseNoneFalse58212.00
297891898795NoneKSHD211Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol foRmtraldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side TeakSqm4532.04532.01.89FalseNoneNoneFalseNoneFalse8565.480
297891998795NoneKSHD212Providing Teak wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.CUBIC METER235649.0235649.00.08FalseNoneNoneFalseNoneFalse18851.920
297892098795NoneKSHD213Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg168.0168.060.0FalseNoneNoneFalseNoneFalse10080.00
297892198795NoneKSHD214Supplying PVC ringtite pipes confoRmtring to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 6 kg/sqcm & class 3Rmtr411.0411.08.0FalseNoneNoneFalseNoneFalse3288.00
17100667930000NoneNoneBuildingsINFRASTRUCTURE WORKS1339531.97
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
297892298796NoneKSHD215ROAD WORK - Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment constructionCum105.0105.062.4FalseNoneNoneFalseNoneFalse6552.00
297892398796NoneKSHD216Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in unifoRmtr layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401- Grading -I MaterialCum2488.02488.062.4FalseNoneNoneFalseNoneFalse155251.20
297892498796NoneKSHD217Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in unifoRmtr layers with paver/ grader in sub-base / base course onwell prepared surface and compacting with vibratory roller to achieve the desired density.Cum2559.02559.054.08FalseNoneNoneFalseNoneFalse138390.720
297892598796NoneKSHD218Prime Coat over WMM/WBM: Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg per Sqm using mechanical meansSqm41.041.0416.0FalseNoneNoneFalseNoneFalse17056.00
297892698796NoneKSHD219Tack coat on Bituminous surface: Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/Sqm on the prepared bituminous surface cleaned with mechanical broomSqm12.012.0416.0FalseNoneNoneFalseNoneFalse4992.00
297892798796NoneKSHD220Dense Graded Bituminous macadam Grading - i for traffic less than 20 mSa Providing and laying Dense Graded Bituminous Macadam with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 4.0 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.Cum8856.08856.029.12FalseNoneNoneFalseNoneFalse257886.720
297892898796NoneKSHD221Bituminous Concrete Grading i for traffic greater than 20 mSa Providing and laying Bituminous Concrete with 40/60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 5.2 per cent of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respectsCum11002.011002.012.48FalseNoneNoneFalseNoneFalse137304.960
297892998796NoneKSHD222PAVER BLOCK - Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in unifoRmtr layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401- Grading -I MaterialCum2360.02360.08.25FalseNoneNoneFalseNoneFalse19470.00
297893098796NoneKSHD223Precast Cement Concrete interlocking Blocks Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Cycle Tracks & Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately if necessary as per relevant technical specification)Sqm1068.01068.055.0FalseNoneNoneFalseNoneFalse58740.00
297893198796NoneKSHD224STORmtr WATER DRAIN - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In all kinds of soils Depth upto 3 mCUBIC METER102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
297893298796NoneKSHD225Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto1.5 m depthCUBIC METER363.0363.082.23FalseNoneNoneFalseNoneFalse29849.490
297893398796NoneKSHD226Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.CUBIC METER266.0266.024.2FalseNoneNoneFalseNoneFalse6437.20
297893498796NoneKSHD227Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & including Centering and shuttering) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5664.05664.06.05FalseNoneNoneFalseNoneFalse34267.20
297893598796NoneKSHD228Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & including Centering and shuttering) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SlabCUBIC METER10510.510510.57.425FalseNoneNoneFalseNoneFalse78040.46250
297893698796NoneKSHD229Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & including Centering and shuttering) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates WallCUBIC METER11461.411461.47.425FalseNoneNoneFalseNoneFalse85100.8950
297893798796NoneKSHD230Providing TheRmtro-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg96.096.01633.5FalseNoneNoneFalseNoneFalse156816.00
297893898796NoneKSHD231SUMP - Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only) In all kinds of soils Depth upto 3 mCUBIC METER102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
297893998796NoneKSHD232Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto1.5 m depthCUBIC METER363.0363.016.36FalseNoneNoneFalseNoneFalse5938.680
297894098796NoneKSHD233Earth work excavation for Foundation by mechanical means for all works & depth upto 1.5 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER425.0425.02.73FalseNoneNoneFalseNoneFalse1160.250
297894198796NoneKSHD234Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)In Hard Rock ( requiring blasting) Depth upto 1.50mCUBIC METER554.0554.010.0FalseNoneNoneFalseNoneFalse5540.00
297894298796NoneKSHD235Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work. (Excavation Payable for Footing Area Only)Depth exceeding 1.5 m, but not exceeding 3 mCUBIC METER623.0623.010.0FalseNoneNoneFalseNoneFalse6230.00
297894398796NoneKSHD236Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.CUBIC METER266.0266.04.51FalseNoneNoneFalseNoneFalse1199.660
297894498796NoneKSHD237Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.CUBIC METER2682.02682.00.96FalseNoneNoneFalseNoneFalse2574.720
297894598796NoneKSHD238Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & including Centering and shuttering) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCUBIC METER5664.05664.00.96FalseNoneNoneFalseNoneFalse5437.440
297894698796NoneKSHD239Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & including Centering and shuttering) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates SlabCUBIC METER10510.510510.52.82FalseNoneNoneFalseNoneFalse29639.610
297894798796NoneKSHD240Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confiRmtring to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & including Centering and shuttering) CUBIC METER0 Design Mix Using 20 mm nominal size graded crushed coarse aggregates WallCUBIC METER11461.411461.44.2FalseNoneNoneFalseNoneFalse48137.880
297894898796NoneKSHD241Providing TheRmtro-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg96.096.0447.03FalseNoneNoneFalseNoneFalse42914.880
297894998796NoneKSHD242Supplying and fixing SFRC frame and cover confoRmtring to IS 12592 (partI)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. completeNos2564.02564.01.0FalseNoneNoneFalseNoneFalse2564.00
17100667930000NoneNoneBuildingsELECTRICAL WORKS11135720.56
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
297895098797NoneKSHD243ELECTRICAL - Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confiRmtring to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.050.0FalseNoneNoneFalseNoneFalse3450.00
297895198797NoneKSHD244Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thickMtr81.081.0603.0FalseNoneNoneFalseNoneFalse48843.00
297895298797NoneKSHD245Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thickMtr106.0106.01496.0FalseNoneNoneFalseNoneFalse158576.00
297895398797NoneKSHD246Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 40 mm dia 2.5 mm thickMtr149.0149.050.0FalseNoneNoneFalseNoneFalse7450.00
297895498797NoneKSHD247Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thickMtr79.079.025.0FalseNoneNoneFalseNoneFalse1975.00
297895598797NoneKSHD248Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thickMtr99.099.025.0FalseNoneNoneFalseNoneFalse2475.00
297895698797NoneKSHD249Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 40 mm dia 2.5 mm thickMtr139.0139.025.0FalseNoneNoneFalseNoneFalse3475.00
297895798797NoneKSHD250Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxNos56.056.0177.0FalseNoneNoneFalseNoneFalse9912.00
297895898797NoneKSHD251Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxNos61.061.015.0FalseNoneNoneFalseNoneFalse915.00
297895998797NoneKSHD252Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wallMtr29.029.010.0FalseNoneNoneFalseNoneFalse290.00
297896098797NoneKSHD253Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit CC FloorMtr69.069.05.0FalseNoneNoneFalseNoneFalse345.00
297896198797NoneKSHD254Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confiRmtring to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be teRmtrinated with sufficient loose length in a wood/PVC round block. complete for Each outlet Short point upto 3m from tapping point to out let via switch boxPoint269.0269.09.0FalseNoneNoneFalseNoneFalse2421.00
297896298797NoneKSHD255Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confiRmtring to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be teRmtrinated with sufficient loose length in a wood/PVC round block. complete for Each outlet Medium point above 3m upto 6m from tapping point to out let via switch boxPoint379.0379.015.0FalseNoneNoneFalseNoneFalse5685.00
297896398797NoneKSHD256Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confiRmtring to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be teRmtrinated with sufficient loose length in a wood/PVC round block. complete for Each outlet Long point above 6m upto 10m from tapping point to out let via switch boxPoint555.0555.0153.0FalseNoneNoneFalseNoneFalse84915.00
297896498797NoneKSHD257Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mSqmMtr19.019.050.0FalseNoneNoneFalseNoneFalse950.00
297896598797NoneKSHD258Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mSqmMtr26.026.0705.24FalseNoneNoneFalseNoneFalse18336.240
297896698797NoneKSHD259Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mSqmMtr42.042.0705.24FalseNoneNoneFalseNoneFalse29620.080
297896798797NoneKSHD260Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mSqmMtr63.063.0705.24FalseNoneNoneFalseNoneFalse44430.120
297896898797NoneKSHD261Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 10-12 WayNos261.0261.048.0FalseNoneNoneFalseNoneFalse12528.00
297896998797NoneKSHD262Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 16-18 WayNos294.0294.03.0FalseNoneNoneFalseNoneFalse882.00
297897098797NoneKSHD263Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 ModuleNos344.0344.048.0FalseNoneNoneFalseNoneFalse16512.00
297897198797NoneKSHD264Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16-18 ModuleNos457.0457.03.0FalseNoneNoneFalseNoneFalse1371.00
297897298797NoneKSHD265Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way SwitchNos102.0102.0249.0FalseNoneNoneFalseNoneFalse25398.00
297897398797NoneKSHD266Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way SwitchNos166.0166.01.0FalseNoneNoneFalseNoneFalse166.00
297897498797NoneKSHD267Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socketNos171.0171.072.0FalseNoneNoneFalseNoneFalse12312.00
297897598797NoneKSHD268Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way SwitchNos180.0180.024.0FalseNoneNoneFalseNoneFalse4320.00
297897698797NoneKSHD269Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal SocketNos236.0236.024.0FalseNoneNoneFalseNoneFalse5664.00
297897798797NoneKSHD270Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V PLUG 10ANos214.0214.012.0FalseNoneNoneFalseNoneFalse2568.00
297897898797NoneKSHD271Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V PLUG 20ANos220.0220.012.0FalseNoneNoneFalseNoneFalse2640.00
297897998797NoneKSHD272Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V PLUG 20ANos280.0280.012.0FalseNoneNoneFalseNoneFalse3360.00
297898098797NoneKSHD273Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V PLUG 30ANos367.0367.012.0FalseNoneNoneFalseNoneFalse4404.00
297898198797NoneKSHD274Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V SOCKET 10ANos217.0217.012.0FalseNoneNoneFalseNoneFalse2604.00
297898298797NoneKSHD275Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V SOCKET 20ANos259.0259.012.0FalseNoneNoneFalseNoneFalse3108.00
297898398797NoneKSHD276Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V SOCKET 20ANos273.0273.012.0FalseNoneNoneFalseNoneFalse3276.00
297898498797NoneKSHD277Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V SOCKET 30ANos297.0297.012.0FalseNoneNoneFalseNoneFalse3564.00
297898598797NoneKSHD278Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended 8 m - Top 70 mm and Bottom 135 mm diaNos15500.015500.09.0FalseNoneNoneFalseNoneFalse139500.00
297898698797NoneKSHD279Supplying, and fixing of Hot dip Galvanized M.S.Bracketsuitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single ARmtr Bracket with 1500 mm Standard 40/50 mm diaNos1844.01844.09.0FalseNoneNoneFalseNoneFalse16596.00
297898798797NoneKSHD280Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal theRmtral dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency Greater than 1301m/w, nominal CRI Greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70WNos5992.05992.07.0FalseNoneNoneFalseNoneFalse41944.00
297898898797NoneKSHD281Supplying of 80W Industrial Range Light with following specifications. System lumen output - 9400 lm, System efficacy of 110 lm/W, Housing : Pressure Die Cast Aluminium with PC lens as Optics with toughened glass, Rated system life of 50,000BH, CCT - 5700K and CRI Greater than 70, Protection: IP66 , IK 07 &THD Less than10% , PF Greater than 0.95, Opr Temp : -10 degree C to +45 degree C, Opr Voltage range: 140 V - 270 V etc., complete a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar /HPL/ GM / GreenLites / Gold Medal/Eveready/ FortuneArrt b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/Everlight.Nos4650.04650.0147.0FalseNoneNoneFalseNoneFalse683550.00
297898998797NoneKSHD282Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI Greater than 70%. efficacy Greater than 80 lumen per W, life Greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18W-20W (T8)Nos330.0330.030.0FalseNoneNoneFalseNoneFalse9900.00
297899098797NoneKSHD283Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA On wall/ ceiling / Rafter / GirdersNos122.0122.0147.0FalseNoneNoneFalseNoneFalse17934.00
297899198797NoneKSHD284TECHNICIAN SHED ELECTRICAL - Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confiRmtring to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25 mm dia 2 mm thickMtr78.078.093.0FalseNoneNoneFalseNoneFalse7254.00
297899298797NoneKSHD285Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confiRmtring to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32 mm dia 2.5 mm thickMtr103.0103.0101.86FalseNoneNoneFalseNoneFalse10491.580
297899398797NoneKSHD286Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 25 mm dia 2 mm thickMtr79.079.05.0FalseNoneNoneFalseNoneFalse395.00
297899498797NoneKSHD287Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 32 mm dia 2.5 mm thickMtr99.099.08.0FalseNoneNoneFalseNoneFalse792.00
297899598797NoneKSHD288Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxNos56.056.013.0FalseNoneNoneFalseNoneFalse728.00
297899698797NoneKSHD289Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxNos61.061.04.0FalseNoneNoneFalseNoneFalse244.00
297899798797NoneKSHD290Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit in brick wallMtr29.029.093.0FalseNoneNoneFalseNoneFalse2697.00
297899898797NoneKSHD291Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete upto 50 mm conduit CC floorMtr69.069.05.0FalseNoneNoneFalseNoneFalse345.00
297899998797NoneKSHD292Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confiRmtring to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be teRmtrinated with sufficient loose length in a wood/PVC round block. complete for Each outlet Short point upto 3m from tapping point to out let via switch boxPoint269.0269.03.0FalseNoneNoneFalseNoneFalse807.00
297900098797NoneKSHD293Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confiRmtring to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be teRmtrinated with sufficient loose length in a wood/PVC round block. complete for Each outlet Medium point above 3m upto 6m from tapping point to out let via switch boxPoint379.0379.03.0FalseNoneNoneFalseNoneFalse1137.00
297900198797NoneKSHD294Point wiring using Copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confiRmtring to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be teRmtrinated with sufficient loose length in a wood/PVC round block. complete for Each outlet Long point above 6m upto 10m from tapping point to out let via switch boxPoint555.0555.016.0FalseNoneNoneFalseNoneFalse8880.00
297900298797NoneKSHD295Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mSqmMtr19.019.05.0FalseNoneNoneFalseNoneFalse95.00
297900398797NoneKSHD296Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mSqmMtr26.026.0107.38FalseNoneNoneFalseNoneFalse2791.880
297900498797NoneKSHD297Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mSqmMtr42.042.0107.38FalseNoneNoneFalseNoneFalse4509.960
297900598797NoneKSHD298Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mSqmMtr63.063.0107.38FalseNoneNoneFalseNoneFalse6764.940
297900698797NoneKSHD299Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 10-12 WayNos261.0261.014.0FalseNoneNoneFalseNoneFalse3654.00
297900798797NoneKSHD300Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 10-12 ModuleNos344.0344.01.0FalseNoneNoneFalseNoneFalse344.00
297900898797NoneKSHD301Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A One Way SwitchNos102.0102.034.0FalseNoneNoneFalseNoneFalse3468.00
297900998797NoneKSHD302Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Two Way SwitchNos166.0166.01.0FalseNoneNoneFalseNoneFalse166.00
297901098797NoneKSHD303Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6A Three Way socketNos171.0171.015.0FalseNoneNoneFalseNoneFalse2565.00
297901198797NoneKSHD304Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16A One Way SwitchNos170.0170.05.0FalseNoneNoneFalseNoneFalse850.00
297901298797NoneKSHD305Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6/16A Universal SocketNos236.0236.05.0FalseNoneNoneFalseNoneFalse1180.00
297901398797NoneKSHD306Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V PLUG 10ANos214.0214.02.0FalseNoneNoneFalseNoneFalse428.00
297901498797NoneKSHD307Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V PLUG 20ANos220.0220.02.0FalseNoneNoneFalseNoneFalse440.00
297901598797NoneKSHD308Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V PLUG 20ANos280.0280.02.0FalseNoneNoneFalseNoneFalse560.00
297901698797NoneKSHD309Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V PLUG 30ANos367.0367.02.0FalseNoneNoneFalseNoneFalse734.00
297901798797NoneKSHD310Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V SOCKET 10ANos217.0217.02.0FalseNoneNoneFalseNoneFalse434.00
297901898797NoneKSHD311Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V SOCKET 20ANos259.0259.02.0FalseNoneNoneFalseNoneFalse518.00
297901998797NoneKSHD312Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V SOCKET 20ANos273.0273.02.0FalseNoneNoneFalseNoneFalse546.00
297902098797NoneKSHD313Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V SOCKET 30ANos297.0297.02.0FalseNoneNoneFalseNoneFalse594.00
297902198797NoneKSHD314Fabricating, supplying and erection of ... ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top.... mm with 3 mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended 8 m - Top 70 mm and Bottom 135 mm diaNos15500.015500.01.0FalseNoneNoneFalseNoneFalse15500.00
297902298797NoneKSHD315Supplying, and fixing of Hot dip Galvanized M.S.Bracketsuitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete Single ARmtr Bracket with 1500 mm Standard 40/50 mm diaNos1844.01844.01.0FalseNoneNoneFalseNoneFalse1844.00
297902398797NoneKSHD316Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Mtr Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200 mm)Nos2677.02677.04.0FalseNoneNoneFalseNoneFalse10708.00
297902498797NoneKSHD317Supplying wall mounting fan suitable to operate at single phase 230v AC. supply 400 mm SweepNos3212.03212.03.0FalseNoneNoneFalseNoneFalse9636.00
297902598797NoneKSHD318Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete 12" Sweep (300 mm)Nos2969.02969.02.0FalseNoneNoneFalseNoneFalse5938.00
297902698797NoneKSHD319Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal theRmtral dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire Greater than IK08. Power Factor Greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency Greater than 1301m/w, nominal CRI Greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 70WNos5992.05992.01.0FalseNoneNoneFalseNoneFalse5992.00
297902798797NoneKSHD320Supplying & fixing of Surface mounting type retrofit type -LED tube ....... W comprising of LED linear source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life Greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition 18W-20W (T8)Nos330.0330.013.0FalseNoneNoneFalseNoneFalse4290.00
297902898797NoneKSHD321Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL /LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA On wall/ ceiling / Rafter / GirdersNos122.0122.013.0FalseNoneNoneFalseNoneFalse1586.00
297902998797NoneKSHD322DIESEL GENERATOR - Supplying, installing, testing and commissioning of 160 kVA/120 kW Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specification. Engine: Diesel generating set are rated at 1500RPM and confoRmtr to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, confoRmtring to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, PeRmtrissible overload of 10% for one hour in 12 hours of operation. Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation. Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, confoRmtring to IS/IEC 60034-1. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have plus or minus 1.0% Voltage regulation (max) in static conditions- IP: 23 protections with insulation class F&H.Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing teRmtrinals, Indicating lA for 'Load On' and 'Set Running', Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and perfoRmtrance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.Operator interface, Provide a record of most recent fault conditions. Fault history stored in the control non volatile memory, Provide Alternator Data. Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Mtr calibration, Engine controls, Power Start operates on 12 VDC batteries,-Auto start mode accepts a ground signal from remote devices to automatically start the DG set The remote start will also wake up the control system from sleep mode.(for complete item description refer estimate document)Set1447891.01447891.01.0FalseNoneNoneFalseNoneFalse1447891.00
297903098797NoneKSHD323Supply, Erection, testing and commissioning of AMF panel suitable for 180kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .A 4 pole contactor for alternator with theRmtral O/L relay,. A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB noRmtrs and KSGEI Acts and RuleSet141293.0141293.02.0FalseNoneNoneFalseNoneFalse282586.00
297903198797NoneKSHD324TRANSFORmtrER -160 KVA Design, Supply, erection, testing and Commission of 11KV/433V, 160 kVA 3 phase HT TransfoRmtrer with Oil Temperature Indicator., Earthing teRmtrinals - 3 nos., Pre-filled Silica-gel breather. Lifting lugs for complete transfoRmtrer. TheRmtroMtr pocket., Oil filling pipe with cap on tank cover/conservator., HV TERmtrINALS with Porcelain Bushings, LV TERmtrINALS Indoor Type Porcelain Bushings with LT Cable box., Bi-metallic connectors on HT side., Oil level indicator on the Oil Conservator., 4 set of wheels for movement., Drain cum sampling valve - 1 no., Filter Valve with plug - 1 no., Pressure relief explosion vent with diaphragm, Externally operated off circuit tap changer switch with handle including all other accessories etc., complete Rating (KVA) -160 KVA No Load Voltage Ratio [KV] -11 / 0.433 KV Rated Current [Amp] -13.12 /333.35 Amps Vector Group -Dyn11 Tapping Range -+5% to -10% @ 2.5% Tap Changer -Off Circuit Tap Changer Steps -6 Steps, 7 Positions Temp. Rise (Oil/Wdg.) -40 / 45 degree C Insulation Level -HV & LV: UnifoRmtr. HV (KVp / KVRmtrs) -75 / 28 LV (KVp / KVRmtrs) -NA / 3 TERmtrINATION: H.V / L.V Cable Box / Cable Box Paint- Epoxy to Shade 631 of IS 5 Oil Temperature Indicator with A/T contacts Winding Temperature Indicator with A/T contacts Buchholz Relay with A/T contacts and with 1 Nos. Shut-off valves Marshalling Box Magnetic Oil Level Gauge with AlaRmtr Contact 1 No. Neutral CT of ratio 630 / 1A, 5P20, 15VA All following standard fittings will be provided in the transfoRmtrer Rating and teRmtrinal marking plate - 1No Earthing teRmtrinals - 2 Nos Lifting lugs - 2 Nos TheRmtroMtr pockets - 1No Air Release Device - 1No Bottom channels - 1Set Drain valve with plug at Bottom- 1No Filter valve with plug at top- 1No Oil conservator with drain plug- 1No Oil filling hole with cap in Conservator- 1No Plain oil level gauge- 1No Dehydrating silica gel breather- 1No Explosion vent with double diaphragm- 1No Bi-directional Flat Rollers- 4No Set450000.0450000.01.0FalseNoneNoneFalseNoneFalse450000.00
297903298797NoneKSHD325OUTER ELECTRICAL WORKS - Supply, Transportation unloading, installation, testing and commissioning of Main MV Panel comprising of the followings and including all other accessories etc., EB Incomer : 1 No 250A 4 Pole Draw out type ACB with O/C, S/C, U/V and E/F Relays DG Incomer: 1 No 250A 4 Pole Draw out type ACB with O/C, S/C, U/V and E/F Relays Busbar: 250A TPN Aluminium Busbars 35KA per 1 Sec. All the neutral busbars shall have half the capacity of phase busbars Outgoing : 3 Nos 100 A TPN MCCB with releases 2 No 160 A TPN MCCB with releases 1 No 200 A TPN MCCB with releases 1 No 250 A TPN MCCB with releases Interlocks: Mechanical type iterlocking with 2 locks and 1 key provided in the both incomers only one supply source can be operated at a time. Wall mounting type fabricated with 16 SWG CRCA sheet enclosure. Door and partition 18 SWG CRCA Sheet. The Panel shall be complete with suitable interconnections and earthing etc. All doors should have proper locking/ sealing arrangements.Set525000.0525000.01.0FalseNoneNoneFalseNoneFalse525000.00
297903398797NoneKSHD326Supply, Transportation unloading, installation, testing and commissioning of Refrigeration Panel-1 comprising of the followings and including all other accessories etc., Incomer : 1 No 250A TPN MCCB Outgoing : 13 No 40A TPN MCCB Bus bars: 250A TPN Aluminium Busbars 35KA per 1 Sec. All the neutral busbars shall have half the capacity of phase busbars Wall mounting type fabricated with 16 SWG CRCA sheet enclouser, Door and partition 18 SWG CRCA sheet. The Panel shall be complete with iterconnections and earthing etc.,Set245000.0245000.01.0FalseNoneNoneFalseNoneFalse245000.00
297903498797NoneKSHD327Supply, Transportation unloading, installation, testing and commissioning of Lift Panel comprising of the followings and including all other accessories etc., Incomer : 1 No 160A TPN MCCB Outgoing : 4 No 63A TPN MCCB Bus bars: 160A TPN Aluminium Busbars 35KA per 1 Sec. All the neutral busbars shall have half the capacity of phase busbars Wall mounting type fabricated with 16 SWG CRCA sheet enclouser, Door and partition 18 SWG CRCA sheet. The Panel shall be complete with iterconnections and earthing etc., All door should have proper locking/ sealing arrnements. Set60000.060000.01.0FalseNoneNoneFalseNoneFalse60000.00
297903598797NoneKSHD328Supply, Transportation unloading, installation, testing and commissioning of Vertical DB 8 Way comprising of the followings and including all other accessories etc., Incomer: 1 No 63A TPN MCCB Outgoing: 2 Nos 16/32A TPN MCB, 18 Nos 6/16A SP MCB The Panel shall be complete with iterconnections and earthing etc., Set22000.022000.01.0FalseNoneNoneFalseNoneFalse22000.00
297903698797NoneKSHD32960 KVAR APFCR PANEL Supply, unloading, installation, testing and commissioning of floor mounting cubicle type APFC panel switch board fabricated out of 16 Swg CRCA and powder coated to Siemens gray shade. Make - Kabil Enterprises / CPRI Approved Panels / Equivalent approved by Engineer InchargeSet125000.0125000.01.0FalseNoneNoneFalseNoneFalse125000.00
297903798797NoneKSHD330Supplying and Fixing of 63A MCCB Isolator in a Metal enclousre for isolation of Refrigent unit near the HVAC UnitSet750.0750.012.0FalseNoneNoneFalseNoneFalse9000.00
297903898797NoneKSHD331Earthing with G.I. earth pipe 4.5 Mtr long, 40 mm dia including accessories , and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal / coke and salt as required. (Electrical DSR: Item No:5.2)Set5087.965087.968.0FalseNoneNoneFalseNoneFalse40703.680
297903998797NoneKSHD332Earthing with G.I.earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr long etc.but with charcoal / coke and salt as required. (Electrical DSR: Item No:5.4)Set5807.125807.124.0FalseNoneNoneFalseNoneFalse23228.480
297904098797NoneKSHD333Supplying and laying 25 mm x 5 mm copper strip at 0.50 Mtr below ground as strip earth electrode , including connection / teRmtrinating with nut , bolt, spring , washer etc.as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spached at 50mm) (Electrical SOR: Item No:5.8)Mtr593.18593.1850.0FalseNoneNoneFalseNoneFalse29659.00
297904198797NoneKSHD334Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required (Electrical SOR: Item No:5.17)Mtr89.3389.33200.0FalseNoneNoneFalseNoneFalse17866.00
297904298797NoneKSHD335Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 3.5 core 185SqmmMtr1948.01948.07.5FalseNoneNoneFalseNoneFalse14610.00
297904398797NoneKSHD336Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 31/2 x 95 SqmmMtr1051.01051.089.0FalseNoneNoneFalseNoneFalse93539.00
297904498797NoneKSHD337Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 31/2 x 70 SqmmMtr827.0827.05.0FalseNoneNoneFalseNoneFalse4135.00
297904598797NoneKSHD338Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 31/2 x 35 SqmmMtr520.0520.02.5FalseNoneNoneFalseNoneFalse1300.00
297904698797NoneKSHD339Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 4 x 16 SqmmMtr313.0313.0126.0FalseNoneNoneFalseNoneFalse39438.00
297904798797NoneKSHD340Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 4 x 10 SqmmMtr262.0262.0470.0FalseNoneNoneFalseNoneFalse123140.00
297904898797NoneKSHD341Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 4 x 6 SqmmMtr217.0217.010.0FalseNoneNoneFalseNoneFalse2170.00
297904998797NoneKSHD342Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 2 x 10 SqmmMtr100.0100.010.0FalseNoneNoneFalseNoneFalse1000.00
297905098797NoneKSHD343Supply and transportation of following XLPE insulated, 1100V grade aRmtroured alluminium cable as per specification confiRmtring to IS:7098 (Part - I)./1554-I Makes: Torent / Universal / Unicab / Havells / KEI / Gloster / Polycab /RR Kabel 2 x 6 SqmmMtr75.075.010.0FalseNoneNoneFalseNoneFalse750.00
297905198797NoneKSHD344Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - Upto 35 sq.mm. (Electrical SOR: Item No:7.1.1)Mtr351.45351.45126.0FalseNoneNoneFalseNoneFalse44282.70
297905298797NoneKSHD345Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 35 sq.mm and upto 95 sq.mmMtr361.21361.217.5FalseNoneNoneFalseNoneFalse2709.0750
297905398797NoneKSHD346Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation , sand cushioning, protective covering and refilling the trench etc.as required - above 95 sq.mm and upto 185 sq.mmMtr370.97370.9796.5FalseNoneNoneFalseNoneFalse35798.6050
297905498797NoneKSHD347Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - upto 35 sq.mm (clamped with 1mm thick saddle)Mtr26.8326.83470.0FalseNoneNoneFalseNoneFalse12610.10
297905598797NoneKSHD348Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - above 35 sq.mm and upto 95 sq.mm (clamped with 25 x3mm MS flat clamp) (Electrical SOR: Item No:7.7.2)Mtr75.4275.425.0FalseNoneNoneFalseNoneFalse377.10
297905698797NoneKSHD349Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required - above 95 sq.mm and upto 185 sq.mm (clamped with 25 / 40 x 3mm MS flat clamp) (Electrical SOR: Item No:7.7.3)Mtr88.4788.4725.0FalseNoneNoneFalseNoneFalse2211.750
297905798797NoneKSHD350Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required - upto 35 sq.mm (clamped with 1 mm thick saddle) (Electrical SOR: Item No:7.8.1)Mtr22.5722.5725.0FalseNoneNoneFalseNoneFalse564.250
297905898797NoneKSHD351Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required - above 35 sq.mm and upto 95 sq.mm (clamped with 1 mm thick saddle) (Electrical SOR: Item No:7.8.2)Mtr52.4152.4125.0FalseNoneNoneFalseNoneFalse1310.250
297905998797NoneKSHD352Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required - above 95 sq.mm and upto 185 sq.mm (clamped with 25 / 40 x 3mm MS flat clamp) (Electrical SOR: Item No:7.8.3)Mtr65.4565.4525.0FalseNoneNoneFalseNoneFalse1636.250
297906098797NoneKSHD353Supplying and making cable route marker with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thickness of 10 cm including inscription duly engraved as required. (Electrical SOR: Item No:7.9)No374.0374.05.0FalseNoneNoneFalseNoneFalse1870.00
297906198797NoneKSHD354Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 2 X 6 sq.mm (19mm) (Electrical SOR: Item No:9.1.1)Per Set104.75104.754.0FalseNoneNoneFalseNoneFalse419.00
297906298797NoneKSHD355Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 2 X 10 sq.mm (19mm) (Electrical SOR: Item No:9.1.2)Per Set105.84105.844.0FalseNoneNoneFalseNoneFalse423.360
297906398797NoneKSHD356Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X10 sq.mm (25 mm) (Electrical SOR: Item No:9.1.32)Per Set110.63110.634.0FalseNoneNoneFalseNoneFalse442.520
297906498797NoneKSHD357Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 4 X16 sq.mm (28 mm) (Electrical SOR: Item No:9.1.33)Per Set112.52112.5218.0FalseNoneNoneFalseNoneFalse2025.360
297906598797NoneKSHD358Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X25 sq.mm (28 mm) (Electrical SOR: Item No:9.1.20)Per Set114.73114.734.0FalseNoneNoneFalseNoneFalse458.920
297906698797NoneKSHD359Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X50 sq.mm (28 mm) (Electrical SOR: Item No:9.1.21)Per Set146.5146.54.0FalseNoneNoneFalseNoneFalse586.00
297906798797NoneKSHD360Supplying and making end teRmtrination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required - 31/2 X120 sq.mm (45 mm) (Electrical SOR: Item No:9.1.25)Per Set222.59222.594.0FalseNoneNoneFalseNoneFalse890.360
297906898797NoneKSHD361GOODS LIFT Design, Detailing, Approval of Client, Supply, Erection, Testing and Commissioning of enitre system for Electric Goods Lift Makes:Kone/Otis/Schindler/ Mitsubishi/Johnson or any other make approved by Engineer-in-Charge.Type:Goods Auto Lift: Load & Capacity-5000 KG Speed : 1 m/s Stops & Openings: 3 stops & 3 openings, Single entrance car Elevator Grouping: Simplex Full Collective Control Pit Height: 2000 mm (required) Head Room height: 4800 mm (required) MAP Floor Position: Topmost floor (TOP) Car Panel Finish: Side walls: Stainless Steel, Rear wall: Stainless Steel, Front wall: Stainless Steel Ceiling & Lighting : Single ceiling tile (CT002) Stainless Steel Flooring: 6 mm ST - Checkered, steel,Car skirting material: Stainless steel Car Door Finish: Stainless steel Landing Signalization: Stainless Steel 7 segment display Flush Mounted Silver brushed Features: Existing light, Fireman Drive, Curtain of Light 169 Beams, Accurate Relevelling, Automatic, Closed Door, Three way intercom, Nudging service, Attendant Service, Lift Announcer Oil Temperature Indicator with A/T contacts Winding Temperature Indicator with A/T contacts Buchholz Relay with A/T contacts and with 1 Nos. Shut-off valves Marshalling Box Magnetic Oil Level Gauge with AlaRmtr Contact 1 No. Neutral CT of ratio 630 / 1A, 5P20, 15VA All following standard fittings will be provided in the transfoRmtrer Rating and teRmtrinal marking plate - 1No Earthing teRmtrinals - 2 Nos Lifting lugs - 2 Nos TheRmtroMtr pockets - 1No Air Release Device - 1No Bottom channels - 1Set Drain valve with plug at Bottom- 1No Filter valve with plug at top- 1No Oil conservator with drain plug- 1No Oil filling hole with cap in Conservator- 1No Plain oil level gauge- 1No Dehydrating silica gel breather- 1No Explosion vent with double diaphragm- 1No Bi-directional Flat Rollers- 4NoNos5911017.05911017.01.0FalseNoneNoneFalseNoneFalse5911017.00
17100667930000NoneNoneBuildingsPLANT AND MACHINERY27434743.73
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
297906998798NoneKSHD362PLANT AND MACHINERY - REFRIGERATION EQUIPMENTS (FREON) - Air Cooled Condensing units with Ceiling suspended Evaporators AIR COOLED CONDENSING UNITS FOR COLD ROOM Air Cooled Scroll Condensing Unit with Energy Efficient Refrigeration Compressor with copper coils with aluminium fins, axial flow fans, HP/LP switch, liquid line filter drier and canopy.Supply of High Efficiency Evaporators, Refrigeration Accessories Comprising of TheRmtrostatic Expansion Valve, Liquid Line Sight Glass, First Charge of gas, Copper Pipes and pipe fittings for suction line and liquid line (considering 12 Rmtr distance between condensing unit and evaporator), suction line insulation, Temperature Controller, Electricals comprising of Single Phase Preventer with under and over voltage protection, MCB, Electrical contactors, Electrical Cables from CDU to Evaporator Fans (Total - 12 Units ) as Per Enclosed Specifications. Design Ambient temperature - 45 Deg C Design Inside Temperature - +4 Deg C High Efficiency Air Cooled Refrigeration Scroll Condensing Units Air cooled Condensing Units with Refrigeration Compressor for the above application with suction and discharge isolation valves, HP/LP Switch, suction line accumulator, Liquid receiver and Canopy. Cooling Capacity of Each Condensing Unit: 6.4 TR Each -4 deg.C SST / +50 deg.C SDT with R404a refrigerant. Number of Condensing Units : Twelve Nos (Two Nos for Each Chamber) Evaporators Evaporators High Efficiency Ceiling Suspended Evaporators Powder Coated Casing, Copper Coil with Aluminium Fins, High Efficiency Axial Flow Fans and Drain Pan with min 7mm Fin Spacing. Number of Evaporators : Twelve Nos (Two Nos for Each Chamber) Refrigeration Controls Refrigeration Controls for the above units comprising of Danfoss TheRmtrostatic Expansion Valves, Hand shut off Valves, etc Refrigerant Piping Refrigeration Pipes and Pipe Fittings comprising of Heavy Duty Seamless Copper Pipes,Pipe Fittings, Nitrile Rubber Insulation for Suction Lines (considering 12 Rmtr distance between CDU and Evaporators ) with first charge of R404A Refrigerant Electrical Panel for Individual Refrigeration Units Weather Proof Electrical Panels for Individual Refrigeration Units with Siemens MCBs, Contactors, OLRs for Compressors, Condenser Fans and Evaporator Fans to be positioned next to the condensing units along with Digital Temperature Indicator cum Controller with real time auto air defrost Electrical Cabling Electrical Cabling from the individual Control panels to the respective compressors, condenser fans, evaporators Supports for Cables and Piping Ladder type GI Cable Tray Supports for Electrical Cables, MS Angle and Channel Supports with painting for Refrigerant Piping Temperature display Individual temperature display with Weather Proof PVC boxes in front of Each room Power Consumption Power Consumption for Each units will be 11.7 Kw x 12 NosSet8031282.08031282.01.0FalseNoneNoneFalseNoneFalse8031282.00
297907098798NoneKSHD363Charges for Installation, Testing and Commissioning of the 8 sets of Refrigeration System for cold RoomJob710211.0710211.01.0FalseNoneNoneFalseNoneFalse710211.00
297907198798NoneKSHD364PUFF PANEL AND ACCESSORIES - Supply of 80 mm Wall panel and ceilingSqm2200.02200.04166.08FalseNoneNoneFalseNoneFalse9165376.00
297907298798NoneKSHD365Ancillaries for wall and ceiling panelsSqm250.0250.04166.08FalseNoneNoneFalseNoneFalse1041520.00
297907398798NoneKSHD366Supply of 80 mm Floor Insulation Puf slabSqm1120.01120.02312.74FalseNoneNoneFalseNoneFalse2590268.80
297907498798NoneKSHD367Floor insulation - vapour barrier - primer, water based bitumen and TarfeltSqm950.0950.02312.74FalseNoneNoneFalseNoneFalse2197103.00
297907598798NoneKSHD368SLIDING DOOR - 1.5 x 2.1 Sliding Door 80mm thickNos115000.0115000.015.0FalseNoneNoneFalseNoneFalse1725000.00
297907698798NoneKSHD369Safety AccessoriesLot7500.07500.015.0FalseNoneNoneFalseNoneFalse112500.00
297907798798NoneKSHD370Labour Charge towards installation of refrigeration equipmentsLot87414.9387414.931.0FalseNoneNoneFalseNoneFalse87414.930
297907898798NoneKSHD371Labour Charge towards installation of 80 mm Wall panel and ceilingSqm250.0250.04166.08FalseNoneNoneFalseNoneFalse1041520.00
297907998798NoneKSHD372Labour Charge towards installation of 80 mm Floor Insulation Puf slabSqm200.0200.02312.74FalseNoneNoneFalseNoneFalse462548.00
297908098798NoneKSHD373Labour Charge Towards Installation of Sliding DoorsNos18000.018000.015.0FalseNoneNoneFalseNoneFalse270000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17100667940001NoneNoneELIGIBILITYTenders from Joint ventures are AcceptableNone
17100667940000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17100667940000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17100668610000NoneNoneELIGIBILITYAll other General Terms and Conditions as per Tender Documents.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneINFORMATION FORMS (6) and (6A)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORMS (6) and (6A)
NoneNoneNoneNoneThe Applicant / tenderer / JV shall provide evidence that Satisfactory completed, at least one similar work of Civil works value not less than Rs. 7.5 Crores as prime contractorCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relavent Document(enclose 4.8 of tender Document)
NoneNoneNoneNoneThe Applicant / tenderer / JV shall provide evidence that Satisfactory completed, at least one similar work of Cold storage works value not less than Rs. 2.50 Crores as prime contractorCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relavent Document(enclose 4.8 of tender Document)
NoneNoneNoneNoneSimilar works means construction of RCC or Steel Multi-storied buildings minimum G Plus 2 with Plinth area not less than 600 sqm. Similarly for the cold stores the contractor or the partner of JV should have executed cold stores/ CA stores for not less than 2000 MT in a single workCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relavent Document(enclose 4.8 of tender Document)
NoneNoneNoneNoneThe Applicant / tenderer / JV shall also provide evidence that it has achieved the minimum monthly and/or annual production rates of the key construction activitiesCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relavent Document(enclose 4.8 of tender Document)
NoneNoneNoneNoneAPPLICATION FORM (1)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- APPLICATION FORM (1)
NoneNoneNoneNoneINFORMATION FORM (1)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (1)
NoneNoneNoneNoneINFORMATION FORM (1A)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (1A)
NoneNoneNoneNoneDETAILS OF PARTICIPATION IN THE JOINT VENTURECapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- DETAILS OF PARTICIPATION IN THE JOINT VENTURE
NoneNoneNoneNoneINFORMATION FORM (2)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (2)
NoneNoneNoneNoneINFORMATION FORM (2A)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (2A)
NoneNoneNoneNoneDetails of Production Levels in Key Construction Activities(Sl. No. 11 of Information Form 2ACapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Details of Production Levels in Key Construction Activities(Sl. No. 11 of Information Form 2A
NoneNoneNoneNoneINFORMATION FORM (3)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (3)
NoneNoneNoneNoneINFORMATION FORM (4)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (4)
NoneNoneNoneNoneINFORMATION FORM (7)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (7)
NoneNoneNoneNoneINFORMATION FORM (8)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (8)
NoneNoneNoneNoneThe Applicant shall provide evidence that it has been actively engaged in the civil works construction business for at least 5 years immediately prior to the date of submission of applications, in the role of prime contractor, management contractor, partner in a joint venture, or subcontractor,and that the Applicant has generated an average annual construction turnover during the above period greater than the Rs.30.00 crores (The average annual turnover is defined as the total of certified payment certificates for works in progress or completed by the firm or firms comprising the Applicant, divided by the number of yearsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Document
NoneNoneNoneNoneThe Applicant / tenderer / JV shall demonstrate that it has access to, or has available, liquid assets, unencumbered real assets, lines of credit, and other financial means (independent of any contractual advance payment) sufficient to meet the construction cash flow requirements for the subject contract(s) in the event of stoppage, start-up, or other delays in payment, of the minimum estimated amount Rs. 3.00 Crores , net of the Applicants commitments for other contractsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Document
NoneNoneNoneNoneINFORMATION FORM (4A)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (4A)
NoneNoneNoneNoneTechnical DocumentsCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Technical Documents
NoneNoneNoneNoneThe audited balance sheets or other financial statements acceptable to the Employer, for the last five years (unless otherwise stated in the PITA) shall be submitted and must demonstrate the current soundness of the Applicants financial position and indicate its prospective long term profitability.If deemed necessary, the Employer shall have the authority to make inquiries with the Applicants bankersCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Relevant Document
NoneNoneNoneNoneINFORMATION FORM (5)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- INFORMATION FORM (5)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Other DocumentsFalseTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsKolarMaluruKolarMALURChawenahally Horticulture Farm, Malur Taluk, Kolar DistrictNoneNoneNoneNoneNoneNone
BuildingsKolarMaluruKolarMALURChawenahally Horticulture Farm, Malur Taluk, Kolar DistrictNoneNoneNoneNoneNoneNone
BuildingsKolarMaluruKolarMALURChawenahally Horticulture Farm, Malur Taluk, Kolar DistrictNoneNoneNoneNoneNoneNone
BuildingsKolarMaluruKolarMALURChawenahally Horticulture Farm, Malur Taluk, Kolar DistrictNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1710073109000
version0
createdDateNone
modifiedDateNone
blockNumberJoint Director of Horticulture Vegetable Section, Lalbagh, Bengaluru-560004
streetNone
cityBengaluru
stateKarnataka
pin560004
tenderRecallDTONone