createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709711660546
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee750.00
emd60000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-03-2024 17:00:00
tenderQueryClose23-03-2024 13:56:25
technicalBidOpen27-03-2024 17:30:00
publishedDate11-03-2024 13:24:37
publishedByPostTMC_CO_BYD
publishedByUserKPE15837 - VINAYKUMAR HOLEPPAGOL
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonsangamesh
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9742812311
tenderSupplierListNone
tenderSchedule
createdTs1709711660579
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2023-24/BD/WORK_INDENT16913
titleconstruction of proposed mrf centre of peb structre at byadagi swm site
descriptionconstruction of proposed mrf centre of peb structure at byadagi swm site
categoryWORKS
categoryTextWorks
ecv3000000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2331
locationNameDMA Town Municipal Council Byadgi
provisionalAmount3000000.0
groupOverheadTotal470237.5
fileNumber01/swm/mrf/byd/24-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17097116610000NoneNoneBuildingsconstruction of proposed mrf centre of peb structre at byadagi swm site2529762.5
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
293612796959None001KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR)Cum105.06105.0629.41FalseNoneNoneFalseNoneFalse3089.81460
293612896959None002KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR)Cum5833.925833.9228.97FalseNoneNoneFalseNoneFalse169008.66240
293612996959None003KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) FootingCum7192.87192.87.12FalseNoneNoneFalseNoneFalse51212.7360
293613096959None004KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) columnCum11016.011016.01.63FalseNoneNoneFalseNoneFalse17956.080
293613196959None005KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) Grade slabCum7192.87192.828.62FalseNoneNoneFalseNoneFalse205857.9360
293613296959None006KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) plinth beamCum9694.089694.084.82FalseNoneNoneFalseNoneFalse46725.46560
293613396959None007KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR)Kg92.1492.142773.1FalseNoneNoneFalseNoneFalse255513.4340
293613496959None008KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR)Cum6580.676580.6716.67FalseNoneNoneFalseNoneFalse109699.76890
293613596959None009KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR)Cum474.0474.0128.79FalseNoneNoneFalseNoneFalse61046.460
293613696959None010KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR)Cum1267.931267.9391.08FalseNoneNoneFalseNoneFalse115483.06440
293613796959None011KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2)Sqm303.85303.85187.56FalseNoneNoneFalseNoneFalse56990.1060
293613896959None012Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2)Kg116.39116.396130.0FalseNoneNoneFalseNoneFalse713470.70
293613996959None013Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2)Sqm585.04585.04518.21FalseNoneNoneFalseNoneFalse303173.57840
293614096959None014KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2)Sqm103.0103.0187.56FalseNoneNoneFalseNoneFalse19318.680
293614196959None015KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2)Sqm75.1975.1991.08FalseNoneNoneFalseNoneFalse6848.30520
293614296959None016KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2)Sqm75.1975.1991.08FalseNoneNoneFalseNoneFalse6848.30520
293614396959None017KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2)Sqm2711.992711.999.0FalseNoneNoneFalseNoneFalse24407.910
293614496959None018KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2)Each25426.5825426.581.0FalseNoneNoneFalseNoneFalse25426.580
293614596959None019KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications.(Item No. 11.35.1.1, Page No. 87, Vol.2)Kg465.56465.56240.0FalseNoneNoneFalseNoneFalse111734.40
293614696959None020LT Control Panel for PHE Equipments, like raw water, treated water, sump water lift pumps including starter control operating system.Completely made by CRCA fabricated, powder coated paint finished front openable compartment for all feeders requirement with IP-54.Main PanelIncomer : MCCB TPN 100A with CBCT ELR & Ph indicators, meter section with all parameters as required100A 4 Wire 25kA 415V Aluminium busbars compartment.Outgoings: 63A MCCB feeder- 01No.Outgoings: 16A MPCB feeder - 01NosOutgoings: 16A MPCB feeder - 02NosOutgoings: 63/40A MCB feeder- 08NosNo85000.085000.01.0FalseNoneNoneFalseNoneFalse85000.00
293614796959None021Sub panel-1Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required63A 4 Wire 16kA 415V Aluminium busbars compartment.Outgoings: 40/63A 4P MCB feeder- 10No.Outgoings: 32A Industrial socket-02Nos.Outgoings: 16A Industrial socket-02Nos.No35000.035000.01.0FalseNoneNoneFalseNoneFalse35000.00
293614896959None022LT CablesSupply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3.5Cx50 Sqmm Al Ar cableMtr300.0300.030.0FalseNoneNoneFalseNoneFalse9000.00
293614996959None023Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx25 Sqmm Al Ar cableMtr180.0180.020.0FalseNoneNoneFalseNoneFalse3600.00
293615096959None024Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx16 Sqmm Al Ar cableMtr120.0120.020.0FalseNoneNoneFalseNoneFalse2400.00
293615196959None025Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.4Cx10 Sqmm Cu Ar cableMtr332.0332.01.0FalseNoneNoneFalseNoneFalse332.00
293615296959None026Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included4Cx6.0 Sqmm Cu Ar cableMtr256.0256.01.0FalseNoneNoneFalseNoneFalse256.00
293615396959None027Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3Cx6.0 Sqmm Cu Un Ar cableMtr316.0316.01.0FalseNoneNoneFalseNoneFalse316.00
293615496959None028Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3Cx4.0 Sqmm Cu Un Ar cableMtr300.0300.01.0FalseNoneNoneFalseNoneFalse300.00
293615596959None029Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.3.5Cx50 Sqmm Al Ar cableSet200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
293615696959None030Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.4Cx25 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
293615796959None031Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.4Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
293615896959None031Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.4Cx16 Sqmm Al Ar cableSet67.267.22.0FalseNoneNoneFalseNoneFalse134.40
293615996959None033Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.4Cx10 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
293616096959None034Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.4Cx6.0 Sqmm Cu Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
293616196959None035Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.3Cx6.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
293616296959None036Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.3Cx4.0 Sqmm Cu Un Ar cableSet54.454.42.0FalseNoneNoneFalseNoneFalse108.80
293616396959None037Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.70 Sqmm Al Ar cable (tinned copper lug)Set250.0250.02.0FalseNoneNoneFalseNoneFalse500.00
293616496959None038Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.25 Sqmm Al Ar cable (tinned copper lug)Set16.016.02.0FalseNoneNoneFalseNoneFalse32.00
293616596959None039Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.16 Sqmm Al Ar cable (tinned copper lug)Set9.959.952.0FalseNoneNoneFalseNoneFalse19.90
293616696959None040Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.10 Sqmm Cu Ar cable (tinned copper lug)Set6.46.41.0FalseNoneNoneFalseNoneFalse6.40
293616796959None041Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.6.0 Sqmm Cu Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
293616896959None042Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.6.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
293616996959None042Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.4.0 Sqmm Cu Un Ar cable (tinned copper lug)Set5.65.61.0FalseNoneNoneFalseNoneFalse5.60
293617096959None044PVC conduits & AccessoriesSupplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduitMtr68.068.010.0FalseNoneNoneFalseNoneFalse680.00
293617196959None045Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.25mm dia PVC 2mm thick conduitMtr80.080.010.0FalseNoneNoneFalseNoneFalse800.00
293617296959None046Point wiring using Copper wire with switchSupply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch boardNos276.0276.01.0FalseNoneNoneFalseNoneFalse276.00
293617396959None047Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 3M upto 6Mtr from switch boardNos386.0386.01.0FalseNoneNoneFalseNoneFalse386.00
293617496959None048Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point above 6M upto 10Mtr from switch boardNos567.0567.01.0FalseNoneNoneFalseNoneFalse567.00
293617596959None049Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 3Mtr upto 6Mtr from switch boardNos721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
293617696959None050Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.2 Light point above 6Mtr upto 10Mtr from switch boardNos721.0721.01.0FalseNoneNoneFalseNoneFalse721.00
293617796959None051Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.3 Light point above 6Mtr upto 10Mtr from switch boardNos1054.01054.03.0FalseNoneNoneFalseNoneFalse3162.00
293617896959None052Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.0 Sqmm Cu FRLS wireMtr18.018.0300.0FalseNoneNoneFalseNoneFalse5400.00
293617996959None053Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.1.5 Sqmm Cu FRLS wireMtr26.026.0300.0FalseNoneNoneFalseNoneFalse7800.00
293618096959None054Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.2.5 Sqmm Cu FRLS wireMtr40.040.0250.0FalseNoneNoneFalseNoneFalse10000.00
293618196959None055Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit .4.0 Sqmm Cu FRLS wireMtr59.059.050.0FalseNoneNoneFalseNoneFalse2950.00
293618296959None056Supply & wiring from distribution board to looping switch boards. Laid wire size 2x2.5 Sqmm Ph-N & 1x1.5Sqmm for E for Lighting circuit wiring laid in existing conduit.6.0 Sqmm Cu FRLS wireMtr115.0115.050.0FalseNoneNoneFalseNoneFalse5750.00
293618396959None057Switches & sockets outlets in Existing modular box6A one way switchNos88.088.04.0FalseNoneNoneFalseNoneFalse352.00
293618496959None058Switches & sockets outlets in Existing modular box6A 5Pin socketNos162.0162.02.0FalseNoneNoneFalseNoneFalse324.00
293618596959None059Switches & sockets outlets in Existing modular boxStepped fan regulatorNos313.0313.02.0FalseNoneNoneFalseNoneFalse626.00
293618696959None060Switches & sockets outlets in Existing modular box6/16A Universal socketNos249.0249.02.0FalseNoneNoneFalseNoneFalse498.00
293618796959None061Supply & fixing of 100W LED light fixture IP 65, included screws accessoris Etc.Considered outdoor type light fitting for equivalent.Nos7390.07390.04.0FalseNoneNoneFalseNoneFalse29560.00
293618896959None062Earthing 25x6mm GI Earth StripMtr92.092.050.0FalseNoneNoneFalseNoneFalse4600.00
293618996959None063Earthing8.0 SWG GI bare wireMtr15.215.250.0FalseNoneNoneFalseNoneFalse760.00
293619096959None064Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall.Supply & installation of GI Ladder type cable tray 300x50mmMtr400.0400.010.0FalseNoneNoneFalseNoneFalse4000.00
293619196959None065Supply & installation of GI PIPE Earthing as per IS:3043 with all installation detailsNos8000.08000.01.0FalseNoneNoneFalseNoneFalse8000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17097116610000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17097116610000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17097116610000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17097117910000NoneNoneELIGIBILITYassociated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs.None
17097118040000NoneNoneELIGIBILITYThe Tender processing fee shall not be refundableNone
17097118160000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt orders.None
17097118260000NoneNoneELIGIBILITYBMS/2007 dated 27.07.2007, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fundNone
17097118370000NoneNoneELIGIBILITYThe intending contractors are requested to note that they should abide by the detailed instructions and conditions contained in the Standard Tender documentsNone
17097118470000NoneNoneELIGIBILITYIn the case of the death of the contractor after executing the agreement / commencement of the work, his legal heir, if is an eligible registered contractor and is willing can execute and compete the work at the accepted tender rates irrespective of the cost of the workNone
17097118650000NoneNoneELIGIBILITYContractor should carryout additional test required to test the suitability of materialsNone
17097118770000NoneNoneELIGIBILITYThe successful Tenderer shall deliver to the Employer a Security deposit in any of the forms given below for an amount equivalent to 5% of the Contract price plus additional security for unbalanced tenders in accordance with the Conditions of Contract.None
17097118950000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extentNone
17097119070000NoneNoneELIGIBILITYMaterials like steel, cement etc., required for the work shall be procured by the tenderer themselves and should got tested by the quality control authority before use on the work at their own cost.None
17097119180000NoneNoneELIGIBILITYThe contractors assessed available tender capacity will be calculated as per the clause 3.6 of STD tender document Attached.None
17097119280000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, loading unloading, transportation, labour, hire charges of machinery curing for concrete works, cost and conveyance of all material and all other such incidental charges necessary for successful completion of works as per the detailed technical specification and direction of Engineer in charge of this work.None
17097119380000NoneNoneELIGIBILITYAll precautions should be taken by the contractor so that there are no damages to such public/ private propertiesNone
17097119470000NoneNoneELIGIBILITYContractor should take all precautionary measures to avoid any damage to the utilities during excavation as well as utility shifting. To that extent the contractor should indemnify the clientNone
17097119570000NoneNoneELIGIBILITYContractor should follow strictly the prevailing rules of labour act.None
17097119660000NoneNoneELIGIBILITYContractor should take all precautions to ensure that no damage is caused to the existing structures which have been constructed by other agencies during project execution. If any damage is caused, it has to be rectified at his own risk and cost.None
17097119730000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and the CO TMC BYADGI r reserves the right to verify the documents before approvalNone
17097119810000NoneNoneELIGIBILITYThe tenderer should maintain the road works mentioned in the Tender document during the defective liability period for 2 yearsNone
17097119880000NoneNoneELIGIBILITYFurther Particulars if any required by the Contractor can be had from the office of the CO TMC BYADGI during office hours on all working daysNone
17097119960000NoneNoneELIGIBILITYThe Chief Officer reserves the rights to Reject or accept any or all the tenders without assigning any reasons.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs.15.0 (50% of estimated cost of tender)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneSatisfactory Performance Certificate
NoneNoneNoneNoneExisting commitment and ongoing works information as per kw2 bid documentPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Existing commitment
NoneNoneNoneNonework done certificatesPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneUnconditional LOC Of amount Rs 9.0lakhs mentioning indent noCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs.30.0Lakhs)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNonePan card and GST Registration certificateOthersPan card and GST Registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Pan card and GST Registration certificate
NoneNoneNoneNoneContractor registration certificateOthersContractor registration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate for 5 years approved by CATrueTechnical Bid
Contractor Registration CertificateTrueTechnical Bid
Similar nature of work done certificate like building or shed work of amount Rs 15.0LakhsTrueTechnical Bid
Unconditional LOC of amount Rs 9.0 lakhs mentioning Indent noTrueTechnical Bid
PAN CertificateTrueTechnical Bid
GST CertificateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsHaveriNoneDharwad SouthBYADGI (SC)swm site byadgiNoneNoneNoneNoneNoneNone
tenderAddressNone
tenderRecallDTONone