tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1710137476000 | 0 | None | None | Buildings | Boys Hostel-Civil work - Upto plinth level | 5083041.99 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983220 | 98964 | None | PWD Volume-3 SR2021-22 Page No7 Item No2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
(ii) By Mechanical Means using Dozer
A. In area of light jungle | ha | 195816.51 | 195816.51 | 0.05 | False | None | None | False | None | False | 9790.8255 | 0 | 2983221 | 98964 | None | PWD Volume-1 SR2021-22 Page No 8 Item No1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 80.53 | 80.53 | 139.524 | False | None | None | False | None | False | 11235.86772 | 0 | 2983222 | 98964 | None | PWD Volume-1 SR2021-22 Page No 8 Item No1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 93.03 | 93.03 | 399.235 | False | None | None | False | None | False | 37140.83205 | 0 | 2983223 | 98964 | None | PWD Volume-1 SR2021-22 Page No 9 Item No1.16.1 | In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 519.14 | 519.14 | 7.9847 | False | None | None | False | None | False | 4145.177158 | 0 | 2983224 | 98964 | None | PWD Volume-1 SR2021-22 Page No 15 Item No2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6881.4 | 6881.4 | 59.2 | False | None | None | False | None | False | 407378.88 | 0 | 2983225 | 98964 | None | PWD Volume-1 SR2021-22 Page No 15 Item No2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6881.4 | 6881.4 | 8.856 | False | None | None | False | None | False | 60941.6784 | 0 | 2983226 | 98964 | None | PWD Volume-2 SR2021-22 Page No 5 Item No4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 117.7 | 117.7 | 465.08 | False | None | None | False | None | False | 54739.916 | 0 | 2983227 | 98964 | None | PWD Volume-1 SR2021-22 Page No 7 Item No1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Total required Qty. for basement filling (456X0.6) | Cum | 252.75 | 252.75 | 399.235 | False | None | None | False | None | False | 100906.64625 | 0 | 2983228 | 98964 | None | PWD Volume-3 SR2021-22 Page No 3 Item No1.01A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.
(Tipper 5.5 m3) | Cum | 146.2 | 146.2 | 407.2197 | False | None | None | False | None | False | 59535.52014 | 0 | 2983229 | 98964 | None | PWD Volume-3 SR2021-22 Page No 3 Item No1.04(i)A | Cost of Haulage Excluding Loading and Unloading Taking output 10 t load and lead 10 km = 100 t.km | T.Km | 14.86 | 14.86 | 651.55 | False | None | None | False | None | False | 9682.033 | 0 | 2983230 | 98964 | None | PWD Volume-1 SR2021-22 Page No 7 Item No1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,
grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 498.07 | 498.07 | 29.07 | False | None | None | False | None | False | 14478.8949 | 0 | 2983231 | 98964 | None | PWD Vol-1 SR 2021-22 Page No 15 Item No 2.2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 125.4 | False | None | None | False | None | False | 928960.692 | 0 | 2983232 | 98964 | None | PWD Volume-1 SR2021-22 Page No 17 Issue rate 2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7411.69 | 7411.69 | 4.3956 | False | None | None | False | None | False | 32578.824564 | 0 | 2983233 | 98964 | None | PWD Volume-1 SR2021-22 Page No 17 Issue rate 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7424.08 | 7424.08 | 14.094 | False | None | None | False | None | False | 104634.98352 | 0 | 2983234 | 98964 | None | PWD Volume-1 SR2021-22 Page No 17 Issue rate 2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7411.69 | 7411.69 | 41.43 | False | None | None | False | None | False | 307066.3167 | 0 | 2983235 | 98964 | None | PWD Vol-12 SR 2021-22 Page No 84 Issue rate3.11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 113.98 | 113.98 | 20399.53 | False | None | None | False | None | False | 2325138.4294 | 0 | 2983236 | 98964 | None | PWD Volume-1 SR2021-22 Page No 115 Item No1 | shuttering Foundation upto Plinth
a. Isolated
Isolated Footing
| Cum | 592.63 | 592.63 | 40.97 | False | None | None | False | None | False | 24280.0511 | 0 | 2983237 | 98964 | None | PWD Volume-1 SR2021-22 Page No 115 Item No2 | shuttering
Foundation, Sub structure of Cross drainages | Cum | 344.07 | 344.07 | 59.2 | False | None | None | False | None | False | 20368.944 | 0 | 2983238 | 98964 | None | PWD Volume-1 SR2021-22 Page No2 Item No8 | shuttering for Columns | Cum | 5196.86 | 5196.86 | 14.094 | False | None | None | False | None | False | 73244.54484 | 0 | 2983239 | 98964 | None | PWD Volume-1 SR2021-22 Page No115 Item No9 | shuttering for Earth retaining structures | Cum | 741.16 | 741.16 | 4.3956 | False | None | None | False | None | False | 3257.842896 | 0 | 2983240 | 98964 | None | PWD Volume-1 SR2021-22 Page No2 Item No1a | shuttering for Plinth Beams of Buildings (50%) | Cum | 3705.84 | 3705.84 | 21.396 | False | None | None | False | None | False | 79290.15264 | 0 | 2983241 | 98964 | None | PWD Volume-1 SR2021-22 Page No2 Item No13.14 | shuttering for Roof Slab of Buildings | Cum | 3705.84 | 3705.84 | 20.04 | False | None | None | False | None | False | 74265.0336 | 0 | 2983242 | 98964 | None | Apendix - Vol-1, Page No-115 | Shuttering
Foundation upto Plinth
b. All other types
| Cum | 222.23 | 222.23 | 60.95 | False | None | None | False | None | False | 13544.9185 | 0 | 2983243 | 98964 | None | Job | The Tenderer (agency) should arrange to obtain (get), Detailed Architectural drawings andElevations, Structural designs and drawings including Soil exploration & proof checking byreputed Government/Semi Government / IISC decided by the Department and the same hasto be furnished to the Department for approval and Providing Consultancy for Architecturaldesign and drawings floor wise. Elevation Furniture layout drawings, 3D view, MFP designand Drawings, Fire Fighting, Internal and External Electrical services including electricalinfrastructure, Lifts, STP, ETP, RO plant, interior layout and liaison with other department andapproval of pollution control board and allied works etc., and any other drawings related tothis project and 6 sets of as built drawings should be submitted to the employer. - - -etc., complete with all lead and lift as per detailed specification and directions of theEngineer incharge | Job | 326435.0 | 326435.0 | 1.0 | False | None | None | False | None | False | 326435.0 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Boys Hostel-Civil work -Above Plinth level | 10641993.54 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983244 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR | Cum | 7664.45 | 7664.45 | 1.39 | False | None | None | False | None | False | 10653.5855 | 0 | 2983245 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR | Cum | 7741.1 | 7741.1 | 5.031 | False | None | None | False | None | False | 38945.4741 | 0 | 2983246 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR | Cum | 7817.74 | 7817.74 | 0.5145 | False | None | None | False | None | False | 4022.22723 | 0 | 2983247 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Cill GROUND FLOOR | Cum | 7664.45 | 7664.45 | 0.09 | False | None | None | False | None | False | 689.8005 | 0 | 2983248 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Cill FIRST FLOOR | Cum | 7741.1 | 7741.1 | 0.56 | False | None | None | False | None | False | 4335.016 | 0 | 2983249 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Staircase GROUND FLOOR | Cum | 7664.45 | 7664.45 | 3.495 | False | None | None | False | None | False | 26787.25275 | 0 | 2983250 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Staircase FIRST FLOOR | Cum | 7741.1 | 7741.1 | 3.495 | False | None | None | False | None | False | 27055.1445 | 0 | 2983251 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plain ChajjaGROUND FLOOR | Cum | 7664.45 | 7664.45 | 0.27 | False | None | None | False | None | False | 2069.4015 | 0 | 2983252 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plain Chajja FIRST FLOOR | Cum | 7741.1 | 7741.1 | 1.69 | False | None | None | False | None | False | 13082.459 | 0 | 2983253 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates GROUND FLOOR | Cum | 7664.45 | 7664.45 | 40.276 | False | None | None | False | None | False | 308693.3882 | 0 | 2983254 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates FIRST FLOOR | Cum | 7741.1 | 7741.1 | 39.172 | False | None | None | False | None | False | 303234.3692 | 0 | 2983255 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR | Cum | 7817.74 | 7817.74 | 10.8245 | False | None | None | False | None | False | 84623.12663 | 0 | 2983256 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall length GROUND FLOOR | Cum | 8043.59 | 8043.59 | 17.811 | False | None | None | False | None | False | 143264.38149 | 0 | 2983257 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesROOF BEAM External wall overall length FIRST FLOOR | Cum | 7741.1 | 7741.1 | 17.811 | False | None | None | False | None | False | 137876.7321 | 0 | 2983258 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesROOF BEAM External wall overall length TERRACE FLOOR | Cum | 7817.74 | 7817.74 | 5.12 | False | None | None | False | None | False | 40026.8288 | 0 | 2983259 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall lengt R.C.C Column C1 (300 X600 ) (Columns) GROUND FLOOR | Cum | 7664.45 | 7664.45 | 14.877 | False | None | None | False | None | False | 114024.02265 | 0 | 2983260 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall lengt R.C.C Column C1 (300 X600 ) (Columns) FIRST FLOOR | Cum | 7741.1 | 7741.1 | 14.877 | False | None | None | False | None | False | 115164.3447 | 0 | 2983261 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall lengtTERRACE FLOOR C1(300 X600 ) (Headroom )C1 (300 X600 ) (Columns) | Cum | 7817.74 | 7817.74 | 9.234 | False | None | None | False | None | False | 72189.01116 | 0 | 2983262 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall lengt RCC WALL GROUND FLOOR | Cum | 7664.45 | 7664.45 | 6.66 | False | None | None | False | None | False | 51045.237 | 0 | 2983263 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall lengt RCC WALLFIRST FLOOR | Cum | 7741.1 | 7741.1 | 6.66 | False | None | None | False | None | False | 51555.726 | 0 | 2983264 | 98965 | None | PWD Volume-3 SR2021-22 Page No17 Item No2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ROOF BEAM External wall overall lengt RCC WALLTerrace FLOOR | Cum | 7817.74 | 7817.74 | 12.43 | False | None | None | False | None | False | 97174.5082 | 0 | 2983265 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No8 | centering for columns - Columns 70% Columns Qty) GROUND FLOOR | Sqm | 5365.12 | 5365.12 | 14.877 | False | None | None | False | None | False | 79816.89024 | 0 | 2983266 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No8 | centering for columns - Columns 70% Columns Qty FIRST FLOOR | Sqm | 5418.77 | 5418.77 | 14.877 | False | None | None | False | None | False | 80615.04129 | 0 | 2983267 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No8 | centering for columns - Columns 70% Columns Qty TERRACE FLOOR
| Sqm | 5472.42 | 5472.42 | 9.234 | False | None | None | False | None | False | 50532.32628 | 0 | 2983268 | 98965 | None | PWD Volume-3 SR2021-22 Page No115 Item No9 | Earth retaining structures (10%) RCC Wall GROUND FLOOR | Sqm | 766.45 | 766.45 | 6.66 | False | None | None | False | None | False | 5104.557 | 0 | 2983269 | 98965 | None | PWD Volume-3 SR2021-22 Page No115 Item No9 | Earth retaining structures (10%) RCC Wall FIRST FLOOR | Sqm | 774.11 | 774.11 | 6.66 | False | None | None | False | None | False | 5155.5726 | 0 | 2983270 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No12 | Beams & Lintels of Building ( 60% ) GROUND FLOOR | Sqm | 4598.67 | 4598.67 | 17.81 | False | None | None | False | None | False | 81902.3127 | 0 | 2983271 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No12 | Beams & Lintels of Building ( 60% ) FIRST FLOOR | Sqm | 4644.66 | 4644.66 | 17.811 | False | None | None | False | None | False | 82726.03926 | 0 | 2983272 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No12 | Beams & Lintels of Building ( 60% ) TERRACE FLOOR | Sqm | 4690.65 | 4690.65 | 5.12 | False | None | None | False | None | False | 24016.128 | 0 | 2983273 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No12 | Beams & Lintels of Building ( 60% ) GROUND FLOOR | Sqm | 4598.67 | 4598.67 | 1.39 | False | None | None | False | None | False | 6392.1513 | 0 | 2983274 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No12 | Beams & Lintels of Building ( 60% ) FIRST FLOOR | Sqm | 4644.66 | 4644.66 | 5.031 | False | None | None | False | None | False | 23367.28446 | 0 | 2983275 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No12 | Beams & Lintels of Building ( 60% ) TERRACE FLOOR | Sqm | 4690.65 | 4690.65 | 0.5145 | False | None | None | False | None | False | 2413.339425 | 0 | 2983276 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No13&14 | Roof Slab of Buildings (50%) Roof Slab Concrete Quantity GROUND FLOOR | Sqm | 3832.23 | 3832.23 | 40.276 | False | None | None | False | None | False | 154346.89548 | 0 | 2983277 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No13&14 | Roof Slab of Buildings (50%) Roof Slab Concrete Quantity FIRST FLOOR | Sqm | 3870.55 | 3870.55 | 39.172 | False | None | None | False | None | False | 151617.1846 | 0 | 2983278 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No13&14 | Roof Slab of Buildings (50%) Roof Slab Concrete Quantity TERRACE FLOOR | Sqm | 3908.87 | 3908.87 | 5.9835 | False | None | None | False | None | False | 23388.723645 | 0 | 2983279 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No13&14 | Staircase Concrete Quantity GROUND FLOOR | Sqm | 3832.23 | 3832.23 | 3.495 | False | None | None | False | None | False | 13393.64385 | 0 | 2983280 | 98965 | None | PWD Volume-3 SR2021-22 Page No2 Item No13&14 | Staircase Concrete Quantity FIRST FLOOR | Sqm | 3870.55 | 3870.55 | 3.495 | False | None | None | False | None | False | 13527.57225 | 0 | 2983281 | 98965 | None | PWD Volume-1 SR2021-22 Page No116 Item No20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) ChejjasGROUND FLOOR | Sqm | 3449.0 | 3449.0 | 0.27 | False | None | None | False | None | False | 931.23 | 0 | 2983282 | 98965 | None | PWD Volume-1 SR2021-22 Page No116 Item No20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) ChejjasFIRST FLOOR | Sqm | 3483.49 | 3483.49 | 1.69 | False | None | None | False | None | False | 5887.0981 | 0 | 2983283 | 98965 | None | PWD Volume-1 SR2021-22 Page No116 Item No20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC CillsGROUND FLOOR | Sqm | 3449.0 | 3449.0 | 0.09 | False | None | None | False | None | False | 310.41 | 0 | 2983284 | 98965 | None | PWD Volume-1 SR2021-22 Page No116 Item No20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC CillsFIRST FLOOR | Sqm | 3483.49 | 3483.49 | 0.56 | False | None | None | False | None | False | 1950.7544 | 0 | 2983285 | 98965 | None | PWD Volume-2 SR2021-22 Page No84 Item No11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)GROUND FLOOR | Kg | 113.99 | 113.99 | 10615.35 | False | None | None | False | None | False | 1210043.7465 | 0 | 2983286 | 98965 | None | PWD Volume-2 SR2021-22 Page No84 Item No11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)FIRST FLOOR | Kg | 115.13 | 115.13 | 11010.83 | False | None | None | False | None | False | 1267676.8579 | 0 | 2983287 | 98965 | None | PWD Volume-2 SR2021-22 Page No84 Item No11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)TERRACE FLOOR | Kg | 116.27 | 116.27 | 2961.4125 | False | None | None | False | None | False | 344323.431375 | 0 | 2983288 | 98965 | None | PWD Volume-2 SR2021-22 Page No17 Item No6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.GROUND FLOOR | Sqm | 1481.84 | 1481.84 | 93.36 | False | None | None | False | None | False | 138344.5824 | 0 | 2983289 | 98965 | None | PWD Volume-2 SR2021-22 Page No17 Item No6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.FIRST FLOOR | Sqm | 1496.66 | 1496.66 | 363.435 | False | None | None | False | None | False | 543938.6271 | 0 | 2983290 | 98965 | None | PWD Volume-2 SR2021-22 Page No17 Item No6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.TERRACE FLOOR | Sqm | 1511.48 | 1511.48 | 118.56 | False | None | None | False | None | False | 179201.0688 | 0 | 2983291 | 98965 | None | PWD Volume-2 SR2021-22 Page No17 Item No6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 100 MM WALL Overall length 100 mm GROUND FLOOR | Sqm | 1164.66 | 1164.66 | 6.84 | False | None | None | False | None | False | 7966.2744 | 0 | 2983292 | 98965 | None | PWD Volume-2 SR2021-22 Page No17 Item No6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. 100 MM WALL Grid A to D along 6 to 7 FIRST FLOOR | Sqm | 1176.31 | 1176.31 | 34.44 | False | None | None | False | None | False | 40512.1164 | 0 | 2983293 | 98965 | None | PWD Volume-2 SR2021-22 Page No98 Item No12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. GROUND FLOOR | Cum | 76326.12 | 76326.12 | 0.1375 | False | None | None | False | None | False | 10494.8415 | 0 | 2983294 | 98965 | None | PWD Volume-2 SR2021-22 Page No98 Item No12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOOR | Cum | 77089.38 | 77089.38 | 0.6875 | False | None | None | False | None | False | 52998.94875 | 0 | 2983295 | 98965 | None | PWD Volume-2 SR2021-22 Page No104 Item No12.57 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.GROUND FLOOR | Sqm | 3647.62 | 3647.62 | 4.2 | False | None | None | False | None | False | 15320.004 | 0 | 2983296 | 98965 | None | PWD Volume-2 SR2021-22 Page No104 Item No12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.FIRST FLOOR | Sqm | 3684.09 | 3684.09 | 21.0 | False | None | None | False | None | False | 77365.89 | 0 | 2983297 | 98965 | None | PWD Volume-2 SR2021-22 Page No103 Item No12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | Nos | 1834.96 | 1834.96 | 12.0 | False | None | None | False | None | False | 22019.52 | 0 | 2983298 | 98965 | None | PWD Volume-2 SR2021-22 Page No103 Item No12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. FIRST FLOOR | Nos | 1853.31 | 1853.31 | 60.0 | False | None | None | False | None | False | 111198.6 | 0 | 2983299 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. GROUND FLOOR | Nos | 135.05 | 135.05 | 2.0 | False | None | None | False | None | False | 270.1 | 0 | 2983300 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. FIRST FLOOR | Nos | 136.4 | 136.4 | 10.0 | False | None | None | False | None | False | 1364.0 | 0 | 2983301 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GROUND FLOOR | Nos | 1090.32 | 1090.32 | 2.0 | False | None | None | False | None | False | 2180.64 | 0 | 2983302 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. FIRST FLOOR | Nos | 1101.22 | 1101.22 | 10.0 | False | None | None | False | None | False | 11012.2 | 0 | 2983303 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GROUND FLOOR | Nos | 1030.85 | 1030.85 | 2.0 | False | None | None | False | None | False | 2061.7 | 0 | 2983304 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIRST FLOOR | Nos | 1041.16 | 1041.16 | 10.0 | False | None | None | False | None | False | 10411.6 | 0 | 2983305 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete GROUND FLOOR | Nos | 216.83 | 216.83 | 4.0 | False | None | None | False | None | False | 867.32 | 0 | 2983306 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete FIRST FLOOR | Nos | 218.99 | 218.99 | 20.0 | False | None | None | False | None | False | 4379.8 | 0 | 2983307 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete GROUND FLOOR | Nos | 137.53 | 137.53 | 4.0 | False | None | None | False | None | False | 550.12 | 0 | 2983308 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete FIRST FLOOR | Nos | 138.9 | 138.9 | 20.0 | False | None | None | False | None | False | 2778.0 | 0 | 2983309 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | Nos | 58.23 | 58.23 | 2.0 | False | None | None | False | None | False | 116.46 | 0 | 2983310 | 98965 | None | PWD Volume-2 SR2021-22 Page No105 Item No12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms FIRST FLOOR | Nos | 58.82 | 58.82 | 10.0 | False | None | None | False | None | False | 588.2 | 0 | 2983311 | 98965 | None | PWD Volume-2 SR2021-22 Page No106 Item No12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type) :GROUND FLOOR | Nos | 249.04 | 249.04 | 8.0 | False | None | None | False | None | False | 1992.32 | 0 | 2983312 | 98965 | None | PWD Volume-2 SR2021-22 Page No106 Item No12.75.1 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type)FIRST FLOOR | Nos | 251.53 | 251.53 | 40.0 | False | None | None | False | None | False | 10061.2 | 0 | 2983313 | 98965 | None | PWD Volume-2 SR2021-22 Page No107 Item No12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm GROUND FLOOR | Nos | 261.43 | 261.43 | 2.0 | False | None | None | False | None | False | 522.86 | 0 | 2983314 | 98965 | None | PWD Volume-2 SR2021-22 Page No107 Item No12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmFIRST FLOOR | Nos | 264.04 | 264.04 | 10.0 | False | None | None | False | None | False | 2640.4 | 0 | 2983315 | 98965 | None | PWD Volume-2 SR2021-22 Page No69 Item No10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm GROUND FLOOR | Nos | 37.17 | 37.17 | 8.0 | False | None | None | False | None | False | 297.36 | 0 | 2983316 | 98965 | None | PWD Volume-2 SR2021-22 Page No69 Item No10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIRST FLOOR | Nos | 37.54 | 37.54 | 40.0 | False | None | None | False | None | False | 1501.6 | 0 | 2983317 | 98965 | None | PWD Volume-2 SR2021-22 Page No179 Item No20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. GROUND FLOOR | Sqm | 621.98 | 621.98 | 0.78 | False | None | None | False | None | False | 485.1444 | 0 | 2983318 | 98965 | None | PWD Volume-2 SR2021-22 Page No179 Item No20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 628.2 | 628.2 | 3.9 | False | None | None | False | None | False | 2449.98 | 0 | 2983319 | 98965 | None | PWD Volume-2 SR2021-22 Page No110 Item No12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)GROUND FLOOR | Sqm | 8970.36 | 8970.36 | 5.4 | False | None | None | False | None | False | 48439.944 | 0 | 2983320 | 98965 | None | PWD Volume-2 SR2021-22 Page No110 Item No12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)FIRST FLOOR | Sqm | 9060.06 | 9060.06 | 25.56 | False | None | None | False | None | False | 231575.1336 | 0 | 2983321 | 98965 | None | PWD Volume-2 SR2021-22 Page No108 Item No12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 6094.27 | 6094.27 | 2.52 | False | None | None | False | None | False | 15357.5604 | 0 | 2983322 | 98965 | None | PWD Volume-2 SR2021-22 Page No103 Item No12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. FIRST FLOOR | Sqm | 594.41 | 594.41 | 9.45 | False | None | None | False | None | False | 5617.1745 | 0 | 2983323 | 98965 | None | PWD Volume-2 SR2021-22 Page No104 Item No12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. FIRST FLOOR | Sqm | 4759.04 | 4759.04 | 9.45 | False | None | None | False | None | False | 44972.928 | 0 | 2983324 | 98965 | None | PWD Volume-2 SR2021-22 Page No85 Item No11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding GROUND FLOOR | Kg | 179.66 | 179.66 | 1335.0 | False | None | None | False | None | False | 239846.1 | 0 | 2983325 | 98965 | None | PWD Volume-2 SR2021-22 Page No85 Item No11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding FIRST FLOOR | Kg | 181.45 | 181.45 | 692.3 | False | None | None | False | None | False | 125617.835 | 0 | 2983326 | 98965 | None | PWD Volume-2 SR2021-22 Page No47 Item No8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 45.84 | 45.84 | 5.4 | False | None | None | False | None | False | 247.536 | 0 | 2983327 | 98965 | None | PWD Volume-2 SR2021-22 Page No47 Item No8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 46.3 | 46.3 | 27.84 | False | None | None | False | None | False | 1288.992 | 0 | 2983328 | 98965 | None | PWD Volume-2 SR2021-22 Page No48 Item No8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 161.07 | 161.07 | 5.4 | False | None | None | False | None | False | 869.778 | 0 | 2983329 | 98965 | None | PWD Volume-2 SR2021-22 Page No48 Item No8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 162.68 | 162.68 | 27.84 | False | None | None | False | None | False | 4529.0112 | 0 | 2983330 | 98965 | None | PWD Volume-2 SR2021-22 Page No47 Item No8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 50.8 | 50.8 | 4.2 | False | None | None | False | None | False | 213.36 | 0 | 2983331 | 98965 | None | PWD Volume-2 SR2021-22 Page No47 Item No8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 51.31 | 51.31 | 21.0 | False | None | None | False | None | False | 1077.51 | 0 | 2983332 | 98965 | None | PWD Volume-2 SR2021-22 Page No83 Item No11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. GROUND FLOOR | Kg | 619.5 | 619.5 | 180.0 | False | None | None | False | None | False | 111510.0 | 0 | 2983333 | 98965 | None | PWD Volume-2 SR2021-22 Page No83 Item No11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.FIRST FLOOR | Kg | 625.7 | 625.7 | 180.0 | False | None | None | False | None | False | 112626.0 | 0 | 2983334 | 98965 | None | PWD Volume-2 SR2021-22 Page No41Item No8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. GROUND FLOOR | Sqm | 218.06 | 218.06 | 280.5 | False | None | None | False | None | False | 61165.83 | 0 | 2983335 | 98965 | None | PWD Volume-2 SR2021-22 Page No41Item No8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. FIRST FLOOR | Sqm | 220.24 | 220.24 | 279.6 | False | None | None | False | None | False | 61579.104 | 0 | 2983336 | 98965 | None | PWD Volume-2 SR2021-22 Page No41Item No8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 222.43 | 222.43 | 27.5 | False | None | None | False | None | False | 6116.825 | 0 | 2983337 | 98965 | None | PWD Volume-2 SR2021-22 Page No42 Item No8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External wall overall length Grid A to D along 3 to 5 GROUND FLOOR | Sqm | 364.27 | 364.27 | 218.14 | False | None | None | False | None | False | 79461.8578 | 0 | 2983338 | 98965 | None | PWD Volume-2 SR2021-22 Page No42 Item No8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External wall overall length Grid A to D along 3 to 5 FIRST FLOOR | Sqm | 367.91 | 367.91 | 624.93 | False | None | None | False | None | False | 229917.9963 | 0 | 2983339 | 98965 | None | PWD Volume-2 SR2021-22 Page No42 Item No8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External wall overall length Grid A to D along 3 to 5 TERRACE FLOOR | Sqm | 371.55 | 371.55 | 118.56 | False | None | None | False | None | False | 44050.968 | 0 | 2983340 | 98965 | None | PWD Volume-2 SR2021-22 Page No42 Item No8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 398.96 | 398.96 | 43.95 | False | None | None | False | None | False | 17534.292 | 0 | 2983341 | 98965 | None | PWD Volume-2 SR2021-22 Page No42 Item No8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. FIRST FLOOR | Sqm | 402.95 | 402.95 | 207.48 | False | None | None | False | None | False | 83604.066 | 0 | 2983342 | 98965 | None | PWD Volume-2 SR2021-22 Page No42 Item No8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. TERRACE FLOOR | Sqm | 406.94 | 406.94 | 188.56 | False | None | None | False | None | False | 76732.6064 | 0 | 2983343 | 98965 | None | PWD Volume-2 SR2021-22 Page No41 Item No8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough Plastering For Dadooing works Toilet Area DadooingFIRST FLOOR | Sqm | 310.34 | 310.34 | 132.3 | False | None | None | False | None | False | 41057.982 | 0 | 2983344 | 98965 | None | PWD Volume-2 SR2021-22 Page No65 Item No9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.FIRST FLOOR | Sqm | 1297.69 | 1297.69 | 132.3 | False | None | None | False | None | False | 171684.387 | 0 | 2983345 | 98965 | None | PWD Volume-2 SR2021-22 Page No60 Item No9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm Electrical Room Skirting GROUN FLOOR | Sqm | 1346.79 | 1346.79 | 5.24 | False | None | None | False | None | False | 7057.1796 | 0 | 2983346 | 98965 | None | PWD Volume-2 SR2021-22 Page No60 Item No9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm Electrical Room Skirting FIRST FLOOR | Sqm | 1360.26 | 1360.26 | 170.13 | False | None | None | False | None | False | 231421.0338 | 0 | 2983347 | 98965 | None | PWD Volume-2 SR2021-22 Page No60 Item No9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.Toilets SH & Toilet FIRST FLOOR | Sqm | 953.56 | 953.56 | 36.24 | False | None | None | False | None | False | 34557.0144 | 0 | 2983348 | 98965 | None | PWD Volume-2 SR2021-22 Page No60 Item No9.12.5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm Corridor SkirtingGROUND FLOOR | Sqm | 2262.41 | 2262.41 | 43.2 | False | None | None | False | None | False | 97736.112 | 0 | 2983349 | 98965 | None | PWD Volume-2 SR2021-22 Page No60 Item No9.12.5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mm Corridor SkirtingFIRST FLOOR | Sqm | 2285.04 | 2285.04 | 45.4 | False | None | None | False | None | False | 103740.816 | 0 | 2983350 | 98965 | None | PWD Volume-2 SR2021-22 Page No64 Item No9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. GROUND FLOOR | Sqm | 2967.41 | 2967.41 | 14.28 | False | None | None | False | None | False | 42374.6148 | 0 | 2983351 | 98965 | None | PWD Volume-2 SR2021-22 Page No64 Item No9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. FIRST FLOOR | Sqm | 2997.08 | 2997.08 | 14.28 | False | None | None | False | None | False | 42798.3024 | 0 | 2983352 | 98965 | None | PWD Volume-2 SR2021-22 Page No Item No9.32 | Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications.GROUND FLOOR | Sqm | 1418.66 | 1418.66 | 10.75 | False | None | None | False | None | False | 15250.595 | 0 | 2983353 | 98965 | None | PWD Volume-2 SR2021-22 Page No75 Item No11.3 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals
20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, lockingarrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of
the Engineer-in-Charge.Main Entry | Sqm | 8131.56 | 8131.56 | 9.6 | False | None | None | False | None | False | 78062.976 | 0 | 2983354 | 98965 | None | PWD Volume-2 SR2021-22 Page No75 Item No11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges ofmachinery complete as per specifications and as per directions of the Engineer-in-Charge.GD | Sqm | 4273.31 | 4273.31 | 6.3 | False | None | None | False | None | False | 26921.853 | 0 | 2983355 | 98965 | None | PWD Volume-2 SR2021-22 Page No50 Item No8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge. Same as ceiling plastering Same as internal plasteringGROUND FLOOR | Sqm | 102.84 | 102.84 | 498.64 | False | None | None | False | None | False | 51280.1376 | 0 | 2983356 | 98965 | None | PWD Volume-2 SR2021-22 Page No50 Item No8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge. Same as ceiling plastering Same as internal plasteringFIRST FLOOR | Sqm | 103.87 | 103.87 | 904.53 | False | None | None | False | None | False | 93953.5311 | 0 | 2983357 | 98965 | None | PWD Volume-2 SR2021-22 Page No50 Item No8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge. Same as ceiling plastering Same as internal plasteringTERRACE FLOOR | Sqm | 104.89 | 104.89 | 146.06 | False | None | None | False | None | False | 15320.2334 | 0 | 2983358 | 98965 | None | PWD Volume-2 SR2021-22 Page No51 Item No8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Same as ceiling plastering Same as internal plasteringGROUND FLOOR | Sqm | 49.56 | 49.56 | 498.64 | False | None | None | False | None | False | 24712.5984 | 0 | 2983359 | 98965 | None | PWD Volume-2 SR2021-22 Page No51 Item No8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Same as ceiling plastering Same as internal plasteringFIRST FLOOR | Sqm | 50.06 | 50.06 | 904.53 | False | None | None | False | None | False | 45280.7718 | 0 | 2983360 | 98965 | None | PWD Volume-2 SR2021-22 Page No51 Item No8.55.2 | TApplying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. Same as ceiling plastering Same as internal plasteringERRACE FLOOR | Sqm | 50.55 | 50.55 | 146.06 | False | None | None | False | None | False | 7383.333 | 0 | 2983361 | 98965 | None | PWD Volume-2 SR2021-22 Page No50 Item No8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Same as ceiling plastering Same as internal plasteringGROUND FLOOR | Sqm | 97.88 | 97.88 | 498.64 | False | None | None | False | None | False | 48806.8832 | 0 | 2983362 | 98965 | None | PWD Volume-2 SR2021-22 Page No50 Item No8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Same as ceiling plastering Same as internal plasteringFIRST FLOOR | Sqm | 98.86 | 98.86 | 904.53 | False | None | None | False | None | False | 89421.8358 | 0 | 2983363 | 98965 | None | PWD Volume-2 SR2021-22 Page No50 Item No8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Same as ceiling plastering Same as internal plasteringTERRACE FLOOR | Sqm | 99.84 | 99.84 | 146.06 | False | None | None | False | None | False | 14582.6304 | 0 | 2983364 | 98965 | None | PWD Volume-2 SR2021-22 Page No46 Item No8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer-in-charge.GROUND FLOOR | Sqm | 168.5 | 168.5 | 43.95 | False | None | None | False | None | False | 7405.575 | 0 | 2983365 | 98965 | None | PWD Volume-2 SR2021-22 Page No46 Item No8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer-in-charge.FIRST FLOOR | Sqm | 170.19 | 170.19 | 207.48 | False | None | None | False | None | False | 35311.0212 | 0 | 2983366 | 98965 | None | PWD Volume-2 SR2021-22 Page No46 Item No8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer-in-charge.TERRACE FLOOR | Sqm | 173.56 | 173.56 | 188.56 | False | None | None | False | None | False | 32726.4736 | 0 | 2983367 | 98965 | None | PWD Volume-2 SR2021-22 Page No131 Item No15.10 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.FIRST FLOOR Toilet | Sqm | 932.29 | 932.29 | 36.24 | False | None | None | False | None | False | 33786.1896 | 0 | 2983368 | 98965 | None | V1, 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7342.31 | 7342.31 | 24.4 | False | None | None | False | None | False | 179152.364 | 0 | 2983369 | 98965 | None | PWD Volume-2 SR2021-22 Page No Item No8.80 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | Sqm | 63.19 | 63.19 | 2171.0 | False | None | None | False | None | False | 137185.49 | 0 | 2983370 | 98965 | None | SR 18-19 | KSRB:15.8.2 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications and as directed by the engineer in charge.. (length of mesh only be measured for payment), Item No.15.35 of NEZ KLB SR 2018-19) | Sqm | 38.41 | 38.41 | 2171.0 | False | None | None | False | None | False | 83388.11 | 0 | 2983371 | 98965 | None | PWD Volume-2 SR2021-22 Page No44 Item No8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 9.91 | 9.91 | 5.4 | False | None | None | False | None | False | 53.514 | 0 | 2983372 | 98965 | None | PWD Volume-2 SR2021-22 Page No44 Item No8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 10.01 | 10.01 | 27.72 | False | None | None | False | None | False | 277.4772 | 0 | 2983373 | 98965 | None | PWD Volume-2 SR2021-22 Page No Item No7.34 | Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges, and hire charges of machinery for cutting, welding, grinding and erection equipments, with all lead and lifts, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work. | Sqm | 4065.47 | 4065.47 | 8.8 | False | None | None | False | None | False | 35776.136 | 0 | 2983374 | 98965 | None | PWD Volume-2 SR2021-22 Page No75 Item No 11.2 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 131.4 | 131.4 | 88.0 | False | None | None | False | None | False | 11563.2 | 0 | 2983375 | 98965 | None | PWD Volume-2 SR2018-19 Page No Item No 39.3 | Manufacturing, supplying and fixing wooden ward robe of 0.60m deep using 19mm thick vinyl bonded water proof block board, shutters allround ward robe, lockable drawers with sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable shutters with 19mm x 6mm thick plain teak wood beading, lipping 1.5mm thick commercial ply vertical support finished in approved 1mm lamination sheet of approved colour, shade and quality on all exposed surfaces. Inner surface painted with 2 coats of white synthetic enamel paint over 2 coats of Patti, one coat of wood primer, including cost of brass fittings, parliamentary hinges, C handles, tower bolts, magnetic catches, approved brand lock, adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour charges, complete as per specification. FIRST FLOOR | Sqm | 13454.95 | 13454.95 | 36.96 | False | None | None | False | None | False | 497294.952 | 0 | 2983376 | 98965 | None | V-1, 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7342.31 | 7342.31 | 23.0 | False | None | None | False | None | False | 168873.13 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Boys Hostel-Plumbing & Sanitation System | 1034445.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983377 | 98966 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet FIRST FLOOR | Each | 6263.2 | 6263.2 | 2.0 | False | None | None | False | None | False | 12526.4 | 0 | 2983378 | 98966 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet SECOND FLOOR | Each | 6325.21 | 6325.21 | 2.0 | False | None | None | False | None | False | 12650.42 | 0 | 2983379 | 98966 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic flushing cistern Urinal Basin FIRST FLOOR | Each | 4424.91 | 4424.91 | 3.0 | False | None | None | False | None | False | 13274.73 | 0 | 2983380 | 98966 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.4.1 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
One urinal basin with 5 litre white P.V.C. automatic flushing cistern Urinal Basin SECOND FLOOR | Each | 4468.72 | 4468.72 | 3.0 | False | None | None | False | None | False | 13406.16 | 0 | 2983381 | 98966 | None | V-2, 14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 2544.08 | 2544.08 | 6.0 | False | None | None | False | None | False | 15264.48 | 0 | 2983382 | 98966 | None | V-2, 14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap | Each | 2544.08 | 2544.08 | 6.0 | False | None | None | False | None | False | 15264.48 | 0 | 2983383 | 98966 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.32 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : mirror
Rectangular shape 453x357 mm FIRST FLOOR | Each | 1087.45 | 1087.45 | 3.0 | False | None | None | False | None | False | 3262.35 | 0 | 2983384 | 98966 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.32 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : mirror
Rectangular shape 453x357 mm SECOND FLOOR | Each | 1098.22 | 1098.22 | 3.0 | False | None | None | False | None | False | 3294.66 | 0 | 2983385 | 98966 | None | PWD Volume-2 SR2021-22 Page No128 Item No14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Towel RailFIRST FLOOR | Each | 475.52 | 475.52 | 6.0 | False | None | None | False | None | False | 2853.12 | 0 | 2983386 | 98966 | None | PWD Volume-2 SR2021-22 Page No128 Item No14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Towel RailSECOND FLOOR | Each | 480.23 | 480.23 | 6.0 | False | None | None | False | None | False | 2881.38 | 0 | 2983387 | 98966 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines Waste PipeGROUND FLOOR | m | 270.1 | 270.1 | 5.0 | False | None | None | False | None | False | 1350.5 | 0 | 2983388 | 98966 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines Waste PipeFIRST FLOOR | m | 272.8 | 272.8 | 6.0 | False | None | None | False | None | False | 1636.8 | 0 | 2983389 | 98966 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines Waste PipeSECOND FLOOR | m | 275.5 | 275.5 | 6.0 | False | None | None | False | None | False | 1653.0 | 0 | 2983390 | 98966 | None | PWD Volume-5 SR2021-22 Page No187 Item NoT090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:50mm nominal bore pipes, From Sink & Urinal linesGROUND FLOOR | m | 172.22 | 172.22 | 3.0 | False | None | None | False | None | False | 516.66 | 0 | 2983391 | 98966 | None | PWD Volume-5 SR2021-22 Page No187 Item NoT090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:50mm nominal bore pipes, From Sink & Urinal linesFIRST FLOOR | m | 173.94 | 173.94 | 3.0 | False | None | None | False | None | False | 521.82 | 0 | 2983392 | 98966 | None | PWD Volume-5 SR2021-22 Page No187 Item NoT090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:50mm nominal bore pipes, From Sink & Urinal linesSECOND FLOOR | m | 175.66 | 175.66 | 3.0 | False | None | None | False | None | False | 526.98 | 0 | 2983393 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Internal wallGROUND FLOOR | m | 152.39 | 152.39 | 9.0 | False | None | None | False | None | False | 1371.51 | 0 | 2983394 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with:50mm nominal bore pipes, Internal wallFIRST FLOOR | m | 153.92 | 153.92 | 20.0 | False | None | None | False | None | False | 3078.4 | 0 | 2983395 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. PVC pipe - OD 75mm and 6 Kg/sqcm, waste linesSECOND FLOOR | m | 155.44 | 155.44 | 20.0 | False | None | None | False | None | False | 3108.8 | 0 | 2983396 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines External GROUND FLOOR | m | 152.39 | 152.39 | 5.0 | False | None | None | False | None | False | 761.95 | 0 | 2983397 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines External FIRST FLOOR | m | 153.92 | 153.92 | 6.0 | False | None | None | False | None | False | 923.52 | 0 | 2983398 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines External SECOND FLOOR | m | 155.44 | 155.44 | 6.0 | False | None | None | False | None | False | 932.64 | 0 | 2983399 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Internal wall GROUND FLOOR | m | 315.94 | 315.94 | 3.0 | False | None | None | False | None | False | 947.82 | 0 | 2983400 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Internal wallFIRST FLOOR | m | 319.1 | 319.1 | 16.0 | False | None | None | False | None | False | 5105.6 | 0 | 2983401 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Internal wall SECOND FLOOR | m | 322.26 | 322.26 | 16.0 | False | None | None | False | None | False | 5156.16 | 0 | 2983402 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines External walGROUND FLOOR | m | 315.94 | 315.94 | 7.0 | False | None | None | False | None | False | 2211.58 | 0 | 2983403 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines External walFIRST FLOOR | m | 319.1 | 319.1 | 18.0 | False | None | None | False | None | False | 5743.8 | 0 | 2983404 | 98966 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines External wall SECOND FLOOR | m | 322.26 | 322.26 | 18.0 | False | None | None | False | None | False | 5800.68 | 0 | 2983405 | 98966 | None | PWD Volume-5 SR2021-22 Page No27 Item No13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameterGROUND FLOOR | m | 313.46 | 313.46 | 12.0 | False | None | None | False | None | False | 3761.52 | 0 | 2983406 | 98966 | None | PWD Volume-5 SR2021-22 Page No27 Item No13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameterFIRST FLOOR | m | 316.6 | 316.6 | 12.0 | False | None | None | False | None | False | 3799.2 | 0 | 2983407 | 98966 | None | PWD Volume-5 SR2021-22 Page No27 Item No13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameterSECOND FLOOR | m | 319.73 | 319.73 | 12.0 | False | None | None | False | None | False | 3836.76 | 0 | 2983408 | 98966 | None | PWD Volume-5 SR2021-22 Page No126 Item No14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Beveled Edge mirror FIRST FLOOR | Nos. | 1215.09 | 1215.09 | 3.0 | False | None | None | False | None | False | 3645.27 | 0 | 2983409 | 98966 | None | PWD Volume-5 SR2021-22 Page No126 Item No14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Beveled Edge mirrorSECOND FLOOR | Nos. | 1227.13 | 1227.13 | 3.0 | False | None | None | False | None | False | 3681.39 | 0 | 2983410 | 98966 | None | PWD Volume-2 SR2021-22 Page No114 Item No13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterShower RoseFIRST FLOOR | Nos. | 275.3 | 275.3 | 3.0 | False | None | None | False | None | False | 825.9 | 0 | 2983411 | 98966 | None | PWD Volume-2 SR2021-22 Page No114 Item No13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameterShower RoseSECOND FLOOR | Nos. | 278.03 | 278.03 | 3.0 | False | None | None | False | None | False | 834.09 | 0 | 2983412 | 98966 | None | PWD Volume-2 SR2021-22 Page No125 Item No14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Wall MixerFIRST FLOOR | Nos. | 7191.73 | 7191.73 | 3.0 | False | None | None | False | None | False | 21575.19 | 0 | 2983413 | 98966 | None | PWD Volume-2 SR2021-22 Page No125 Item No14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Wall MixerSECOND FLOOR | Nos. | 7262.94 | 7262.94 | 3.0 | False | None | None | False | None | False | 21788.82 | 0 | 2983414 | 98966 | None | PWD Volume-5 SR2021-22 Page No112 Item NoH160A | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. completea)For DI/CI puddle flanges of 80mm dia.Puddle Flanges TERRACE FLOOR(OHT) | No. | 1890.71 | 1890.71 | 2.0 | False | None | None | False | None | False | 3781.42 | 0 | 2983415 | 98966 | None | 1st Addenda S.N-10 item No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes Cold Water SupplyGROUND FLOOR | m | 379.13 | 379.13 | 6.0 | False | None | None | False | None | False | 2274.78 | 0 | 2983416 | 98966 | None | 1st Addenda S.N-10 item No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes Cold Water SupplyFIRST FLOOR | m | 382.92 | 382.92 | 8.0 | False | None | None | False | None | False | 3063.36 | 0 | 2983417 | 98966 | None | 1st Addenda S.N-10 item No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes Cold Water SupplySECOND FLOOR | m | 386.71 | 386.71 | 8.0 | False | None | None | False | None | False | 3093.68 | 0 | 2983418 | 98966 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply GROUND FLOOR | m | 462.14 | 462.14 | 12.0 | False | None | None | False | None | False | 5545.68 | 0 | 2983419 | 98966 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply FIRST FLOOR | m | 466.76 | 466.76 | 16.0 | False | None | None | False | None | False | 7468.16 | 0 | 2983420 | 98966 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Cold Water Supply SECOND FLOOR | m | 471.38 | 471.38 | 16.0 | False | None | None | False | None | False | 7542.08 | 0 | 2983421 | 98966 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Hot Water SupplyGROUND FLOOR | m | 462.14 | 462.14 | 2.0 | False | None | None | False | None | False | 924.28 | 0 | 2983422 | 98966 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Hot Water SupplyFIRST FLOOR | m | 466.76 | 466.76 | 4.0 | False | None | None | False | None | False | 1867.04 | 0 | 2983423 | 98966 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes Hot Water Supply SECOND FLOOR | m | 471.38 | 471.38 | 4.0 | False | None | None | False | None | False | 1885.52 | 0 | 2983424 | 98966 | None | 1st Addenda S.N-10 item No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Hot Water SupplyGROUND FLOOR | m | 589.76 | 589.76 | 3.0 | False | None | None | False | None | False | 1769.28 | 0 | 2983425 | 98966 | None | 1st Addenda S.N-10 item No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Hot Water SupplyFIRST FLOOR | m | 595.66 | 595.66 | 5.0 | False | None | None | False | None | False | 2978.3 | 0 | 2983426 | 98966 | None | 1st Addenda S.N-10 item No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Hot Water Supply SECOND FLOOR | m | 601.55 | 601.55 | 5.0 | False | None | None | False | None | False | 3007.75 | 0 | 2983427 | 98966 | None | 1st Addenda S.N-10 item No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water SupplGROUND FLOOR | m | 688.88 | 688.88 | 2.0 | False | None | None | False | None | False | 1377.76 | 0 | 2983428 | 98966 | None | 1st Addenda S.N-10 item No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water SupplFIRST FLOOR | m | 695.77 | 695.77 | 4.0 | False | None | None | False | None | False | 2783.08 | 0 | 2983429 | 98966 | None | 1st Addenda S.N-10 item No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply SECOND FLOOR | m | 702.66 | 702.66 | 4.0 | False | None | None | False | None | False | 2810.64 | 0 | 2983430 | 98966 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 40mm nominal dia pipes from Sump to Bldg | m | 581.09 | 581.09 | 100.0 | False | None | None | False | None | False | 58109.0 | 0 | 2983431 | 98966 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 40mm nominal dia pipes Cold Water Supply- Down Take GROUND FLOOR | m | 581.09 | 581.09 | 12.0 | False | None | None | False | None | False | 6973.08 | 0 | 2983432 | 98966 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 40mm nominal dia pipes Cold Water Supply- Down TakeFIRST FLOOR | m | 586.9 | 586.9 | 8.0 | False | None | None | False | None | False | 4695.2 | 0 | 2983433 | 98966 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 40mm nominal dia pipes Cold Water Supply- Down TakeSECOND FLOOR | m | 592.71 | 592.71 | 8.0 | False | None | None | False | None | False | 4741.68 | 0 | 2983434 | 98966 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 40mm nominal dia pipes Cold Water Supply - Ring Main TERRACE FLOOR | m | 598.52 | 598.52 | 30.0 | False | None | None | False | None | False | 17955.6 | 0 | 2983435 | 98966 | None | 1st Addenda S.N-11 item No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the walls etc. 50mm nominal dia pipes Cold Water Supply- from Tank TERRACE FLOOR | m | 895.87 | 895.87 | 13.0 | False | None | None | False | None | False | 11646.31 | 0 | 2983436 | 98966 | None | 1st Addenda S.N-12item No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.TERRACE FLOOR | Ltr | 9.92 | 9.92 | 3000.0 | False | None | None | False | None | False | 29760.0 | 0 | 2983437 | 98966 | None | PWD Volume-2 SR2021-22 Page No113 Item No13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreTERRACE FLOOR | Nos. | 475.77 | 475.77 | 2.0 | False | None | None | False | None | False | 951.54 | 0 | 2983438 | 98966 | None | PWD Volume-5 SR2021-22 Page NoN180E Item No16.5 | For 40 mm dia GM (Copper alloy) Gate valves Cold water supply TERRACE FLOOR | Nos. | 1914.25 | 1914.25 | 5.0 | False | None | None | False | None | False | 9571.25 | 0 | 2983439 | 98966 | None | PWD Volume-5 SR2021-22 Page NoN180F Item No16.5 | For 50 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2154.17 | 2154.17 | 2.0 | False | None | None | False | None | False | 4308.34 | 0 | 2983440 | 98966 | None | 1st Addenda S.N-16item No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.FIRST FLOOR | Each | 304.08 | 304.08 | 10.0 | False | None | None | False | None | False | 3040.8 | 0 | 2983441 | 98966 | None | 1st Addenda S.N-16item No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.SECOND FLOOR | Each | 307.09 | 307.09 | 10.0 | False | None | None | False | None | False | 3070.9 | 0 | 2983442 | 98966 | None | PWD SR2018-19 Page No Item No11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOOR | Nos | 22121.1 | 22121.1 | 3.0 | False | None | None | False | None | False | 66363.3 | 0 | 2983443 | 98966 | None | PWD SR2018-19 Page No Item No11.38 | KSRB 12-5.2 : Constructing brick masonry circular type manhole 1.67 m internal dia at bottom, 0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOOR | Nos | 36248.18 | 36248.18 | 3.0 | False | None | None | False | None | False | 108744.54 | 0 | 2983444 | 98966 | None | PWD SR2018-19 Page No Item No11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 TERRACE FLOOR FLOOR(OHT) | Nos | 375.41 | 375.41 | 13.0 | False | None | None | False | None | False | 4880.33 | 0 | 2983445 | 98966 | None | PWD SR2021-22 Page No Item No11.50.3 | Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 450x450mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 450x450mm | Nos. | 7748.7 | 7748.7 | 3.0 | False | None | None | False | None | False | 23246.1 | 0 | 2983446 | 98966 | None | PWD Volume-1 SR2021-22 Page No 10 Item No117.1 | Earth work excavation for pipeline/cables trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 mGROUND FLOOR | Cum | 582.33 | 582.33 | 144.0 | False | None | None | False | None | False | 83855.52 | 0 | 2983447 | 98966 | None | PWD Volume-2 SR2021-22 Page No 70 Item No10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal PartitionsFIRST FLOOR | Sqm | 2084.81 | 2084.81 | 3.6 | False | None | None | False | None | False | 7505.316 | 0 | 2983448 | 98966 | None | PWD Volume-2 SR2021-22 Page No 70 Item No10.8 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Urinal PartitionsSECOND FLOOR | Sqm | 2105.45 | 2105.45 | 3.6 | False | None | None | False | None | False | 7579.62 | 0 | 2983449 | 98966 | None | PWD Volume-2 SR2021-22 Page No 129 Item No14.34.1 | Providing and fixing toilet paper holder :C.P. brass Toilet Paper Holder FIRST FLOOR | Each | 600.66 | 600.66 | 3.0 | False | None | None | False | None | False | 1801.98 | 0 | 2983450 | 98966 | None | PWD Volume-2 SR2021-22 Page No 129 Item No14.34.1 | Providing and fixing toilet paper holder :C.P. brass Toilet Paper Holder SECOND FLOOR | Each | 606.61 | 606.61 | 3.0 | False | None | None | False | None | False | 1819.83 | 0 | 2983451 | 98966 | None | 2018-19, SR 12.113.2 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cmsFIRST FLOOR | Nos. | 336.3 | 336.3 | 8.0 | False | None | None | False | None | False | 2690.4 | 0 | 2983452 | 98966 | None | 2018-19 SR, 12.113.2 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cms second floor | Nos. | 336.3 | 336.3 | 8.0 | False | None | None | False | None | False | 2690.4 | 0 | 2983453 | 98966 | None | PWD Volume-5 SR2021-22 Page No 134Item NoM020D | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ).Pipes of SN4, 160mm dia.GROUND FLOOR | m | 688.88 | 688.88 | 40.0 | False | None | None | False | None | False | 27555.2 | 0 | 2983454 | 98966 | None | PWD Volume-5 SR2021-22 Page No 134Item NoM020E | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work Pipes of SN4, 200mm dia.GROUND FLOOR | m | 688.88 | 688.88 | 100.0 | False | None | None | False | None | False | 68888.0 | 0 | 2983455 | 98966 | None | PWD Volume-5 SR2021-22 Page No 134Item NoM020D | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).Pipes of SN4, 160mm dia.GROUND FLOOR | m | 688.88 | 688.88 | 20.0 | False | None | None | False | None | False | 13777.6 | 0 | 2983456 | 98966 | None | 1st AddendaS.No-18 Item no 13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design.GROUND FLOOR | Nos. | 2848.46 | 2848.46 | 8.0 | False | None | None | False | None | False | 22787.68 | 0 | 2983457 | 98966 | None | water supply board, 13.6 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" | Nos | 42421.0 | 42421.0 | 2.0 | False | None | None | False | None | False | 84842.0 | 0 | 2983458 | 98966 | None | Electrical SR Page No 27 Item No 7.2.1 | Supplying ...litres capacity vertical/horizontal type wall
mounting Electrical water heater with 22 SWG copper/SS sheet
metal inner Container tinned inside Fiber body outside, filled
with glass wool between inner and outer container for thermal
insulation complete. The inlet and outlet pipes so arranged that
water flow inside results in water to flow out from the inner
container without turbulence. The Inner container shall have
direct immersion type copper tube nickel plate. 2kW capacity
element with a neon indicator fitted with 20A capacity 25 to 85
degree Centigrade range thermostat. The water heater shall
completely be wired with 40/0.0076 inch 3 core copper flexible
wire of 1.5 meters length and the outer container provided with
heavy gauge brackets for wall mounting.25 L ALL FLOOR | No. | 12154.0 | 12154.0 | 5.0 | False | None | None | False | None | False | 60770.0 | 0 | 2983459 | 98966 | None | PWD SR2021-22 Page No Item No11.50.2 | Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600mm
| Nos | 12625.41 | 12625.41 | 3.0 | False | None | None | False | None | False | 37876.23 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Boys Hostel-Internal Electrification | 1988106.15 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983460 | 98967 | None | ELE SR NO 2021-22 Item No 1.1.1 | Open Conduit System.Supply Heavy gauge PVC conduit pipe - dia - mm thich confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC eall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF Screws.19/20mm dia 2mm thick | m | 80.24 | 80.24 | 50.0 | False | None | None | False | None | False | 4012.0 | 0 | 2983461 | 98967 | None | ELE SR NO 2021-22 Item No 1.1.2 | Open Conduit System.Supply Heavy gauge PVC conduit pipe - dia - mm thich confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC eall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF Screws.25 mm dia 2mm thick | m | 94.4 | 94.4 | 100.0 | False | None | None | False | None | False | 9440.0 | 0 | 2983462 | 98967 | None | ELE SR NO 2021-22 Item No 1.2.1 | Supplying heavy gauge PVC conduit pipe - mm dia - thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and usused ways of junction boxes and pipe ends should be covered using PVC end closures, run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick
| m | 71.98 | 71.98 | 852.5 | False | None | None | False | None | False | 61362.95 | 0 | 2983463 | 98967 | None | ELE SR NO 2021-22 Item No 1.2.2 | Supplying heavy gauge PVC conduit pipe - mm dia - thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and usused ways of junction boxes and pipe ends should be covered using PVC end closures, run with 18SWG GI fish wire wherever necessary.25 mm dia 2mm thick
| m | 82.6 | 82.6 | 372.0 | False | None | None | False | None | False | 30727.2 | 0 | 2983464 | 98967 | None | ELE SR NO 2021-22 Item No 1.2.3 | Supplying heavy gauge PVC conduit pipe - mm dia - thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end closures, run with 18SWG GI fish wire wherever necessary.32mm dia 2.5mm thick | m | 109.74 | 109.74 | 30.0 | False | None | None | False | None | False | 3292.2 | 0 | 2983465 | 98967 | None | ELE SR NO 2021-22 Item No 1.3.1 | Supplying heavy gauge PVC conduit pipe - mm dia - thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 19/20mm dia 2mm thick
| m | 88.5 | 88.5 | 155.0 | False | None | None | False | None | False | 13717.5 | 0 | 2983466 | 98967 | None | ELE SR NO 2021-22 Item No 1.3.2 | Supplying heavy gauge PVC conduit pipe - mm dia - thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 25 mm dia 2mm thick
| m | 94.4 | 94.4 | 384.4 | False | None | None | False | None | False | 36287.36 | 0 | 2983467 | 98967 | None | ELE SR NO 2021-22 Item No 1.3.3 | Supplying heavy gauge PVC conduit pipe - mm dia - thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 32mm dia 2.5mm thick
| m | 123.9 | 123.9 | 40.0 | False | None | None | False | None | False | 4956.0 | 0 | 2983468 | 98967 | None | ELE SR NO 2021-22 Item No 1.4.5 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/lconduit entry as required with one coat of primer of approved make etc.200x200x65 mm
| Each | 395.3 | 395.3 | 4.0 | False | None | None | False | None | False | 1581.2 | 0 | 2983469 | 98967 | None | ELE SR NO 2021-22 Item No 1.5.1 | Supplying and fixing PVC/Metal conduit Deep Junction box19/20mm deep Junction box
| Each | 57.82 | 57.82 | 90.0 | False | None | None | False | None | False | 5203.8 | 0 | 2983470 | 98967 | None | ELE SR NO 2021-22 Item No 1.5.2 | Supplying and fixing PVC/Metal conduit Deep Junction box25mm deep Junction box
| Each | 60.18 | 60.18 | 8.0 | False | None | None | False | None | False | 481.44 | 0 | 2983471 | 98967 | None | ELE SR NO 2021-22 Item No 1.5.3 | Supplying and fixing PVC/Metal conduit Deep Junction box32mm deep Junction box
| Each | 81.42 | 81.42 | 2.0 | False | None | None | False | None | False | 162.84 | 0 | 2983472 | 98967 | None | ELE SR NO 2021-22 Item No 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit in brick wall
| m | 30.68 | 30.68 | 10.0 | False | None | None | False | None | False | 306.8 | 0 | 2983473 | 98967 | None | ELE SR NO 2021-22 Item No 1.7.2 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floor
| m | 73.16 | 73.16 | 10.0 | False | None | None | False | None | False | 731.6 | 0 | 2983474 | 98967 | None | ELE SR NO 2021-22 Item No 1.8.1 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required.20mm
| m | 31.86 | 31.86 | 10.0 | False | None | None | False | None | False | 318.6 | 0 | 2983475 | 98967 | None | ELE SR NO 2021-22 Item No 1.8.2 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required.25mm
| m | 33.04 | 33.04 | 10.0 | False | None | None | False | None | False | 330.4 | 0 | 2983476 | 98967 | None | ELE SR NO 2021-22 Item No 1.8.3 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required.32mm
| m | 48.38 | 48.38 | 10.0 | False | None | None | False | None | False | 483.8 | 0 | 2983477 | 98967 | None | ELE SR NO 2021-22 Item No 1.9.1 | Supplying PVC/GI Flexible conduit pipe - mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y.20mm
| m | 29.5 | 29.5 | 10.0 | False | None | None | False | None | False | 295.0 | 0 | 2983478 | 98967 | None | ELE SR NO 2021-22 Item No 1.9.2 | Supplying PVC/GI Flexible conduit pipe - mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y.25mm
| m | 36.58 | 36.58 | 10.0 | False | None | None | False | None | False | 365.8 | 0 | 2983479 | 98967 | None | ELE SR NO 2021-22 Item No 1.9.3 | Supplying PVC/GI Flexible conduit pipe - mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y.32mm
| m | 48.38 | 48.38 | 10.0 | False | None | None | False | None | False | 483.8 | 0 | 2983480 | 98967 | None | ELE SR NO 2021-22 Item No 1.1.2 | Supplying and fixing of Metal Fan box with Round Hook.
| No | 192.34 | 192.34 | 34.0 | False | None | None | False | None | False | 6539.56 | 0 | 2983481 | 98967 | None | ELE SR NO 2021-22 Item No 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switch"
| Point | 296.18 | 296.18 | 21.0 | False | None | None | False | None | False | 6219.78 | 0 | 2983482 | 98967 | None | ELE SR NO 2021-22 Item No 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch
| Point | 425.98 | 425.98 | 34.0 | False | None | None | False | None | False | 14483.32 | 0 | 2983483 | 98967 | None | ELE SR NO 2021-22 Item No 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 639.56 | 639.56 | 94.0 | False | None | None | False | None | False | 60118.64 | 0 | 2983484 | 98967 | None | ELE SR NO 2021-22 Item No 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 791.78 | 791.78 | 51.0 | False | None | None | False | None | False | 40380.78 | 0 | 2983485 | 98967 | None | ELE SR NO 2021-22 Item No 2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches | Point | 1155.22 | 1155.22 | 1.0 | False | None | None | False | None | False | 1155.22 | 0 | 2983486 | 98967 | None | ELE SR NO 2021-22 Item No 2.3.1 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.1 Sq.mm | m | 21.24 | 21.24 | 75.0 | False | None | None | False | None | False | 1593.0 | 0 | 2983487 | 98967 | None | ELE SR NO 2021-22 Item No 2.3.2 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.1.5 Sq.mm
| m | 30.68 | 30.68 | 1000.0 | False | None | None | False | None | False | 30680.0 | 0 | 2983488 | 98967 | None | ELE SR NO 2021-22 Item No 2.3.3 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.2.5 Sq.mm
| m | 47.2 | 47.2 | 1850.0 | False | None | None | False | None | False | 87320.0 | 0 | 2983489 | 98967 | None | ELE SR NO 2021-22 Item No 2.3.4 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.4 Sq.mm
| m | 69.62 | 69.62 | 300.0 | False | None | None | False | None | False | 20886.0 | 0 | 2983490 | 98967 | None | ELE SR NO 2021-22 Item No 2.3.5 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.6 Sq.mm
| m | 102.66 | 102.66 | 40.0 | False | None | None | False | None | False | 4106.4 | 0 | 2983491 | 98967 | None | ELE SR NO 2021-22 Item No 2.3.6 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.10 Sq.mm
| m | 185.26 | 185.26 | 120.0 | False | None | None | False | None | False | 22231.2 | 0 | 2983492 | 98967 | None | ELE SR NO 2021-22 Item No 2.5.8 | Supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor conforming to IS 8130-1984 and (Virgin) PVC Insulation sheathed suitable for working voltage upto 1100V as per IS 694:2010.3C x 2.5 mm2
| m | 375.24 | 375.24 | 50.0 | False | None | None | False | None | False | 18762.0 | 0 | 2983493 | 98967 | None | ELE SR NO 2021-22 Item No 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way
| Each | 145.14 | 145.14 | 36.0 | False | None | None | False | None | False | 5225.04 | 0 | 2983494 | 98967 | None | ELE SR NO 2021-22 Item No 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way
| Each | 162.84 | 162.84 | 7.0 | False | None | None | False | None | False | 1139.88 | 0 | 2983495 | 98967 | None | ELE SR NO 2021-22 Item No 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way
| Each | 250.16 | 250.16 | 25.0 | False | None | None | False | None | False | 6254.0 | 0 | 2983496 | 98967 | None | ELE SR NO 2021-22 Item No 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way
| Each | 295.0 | 295.0 | 11.0 | False | None | None | False | None | False | 3245.0 | 0 | 2983497 | 98967 | None | ELE SR NO 2021-22 Item No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12Way
| Each | 383.5 | 383.5 | 4.0 | False | None | None | False | None | False | 1534.0 | 0 | 2983498 | 98967 | None | ELE SR NO 2021-22 Item No 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16-18Way
| Each | 417.72 | 417.72 | 16.0 | False | None | None | False | None | False | 6683.52 | 0 | 2983499 | 98967 | None | ELE SR NO 2021-22 Item No 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module
| Each | 179.36 | 179.36 | 36.0 | False | None | None | False | None | False | 6456.96 | 0 | 2983500 | 98967 | None | ELE SR NO 2021-22 Item No 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module
| Each | 206.5 | 206.5 | 7.0 | False | None | None | False | None | False | 1445.5 | 0 | 2983501 | 98967 | None | ELE SR NO 2021-22 Item No 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module
| Each | 287.92 | 287.92 | 25.0 | False | None | None | False | None | False | 7198.0 | 0 | 2983502 | 98967 | None | ELE SR NO 2021-22 Item No 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module
| Each | 356.36 | 356.36 | 11.0 | False | None | None | False | None | False | 3919.96 | 0 | 2983503 | 98967 | None | ELE SR NO 2021-22 Item No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module
| Each | 428.34 | 428.34 | 4.0 | False | None | None | False | None | False | 1713.36 | 0 | 2983504 | 98967 | None | ELE SR NO 2021-22 Item No 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16-18 Module
| Each | 475.54 | 475.54 | 16.0 | False | None | None | False | None | False | 7608.64 | 0 | 2983505 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way Switch
| Each | 103.84 | 103.84 | 285.0 | False | None | None | False | None | False | 29594.4 | 0 | 2983506 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch
| Each | 179.36 | 179.36 | 6.0 | False | None | None | False | None | False | 1076.16 | 0 | 2983507 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket
| Each | 191.16 | 191.16 | 90.0 | False | None | None | False | None | False | 17204.4 | 0 | 2983508 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator.
| Each | 369.34 | 369.34 | 34.0 | False | None | None | False | None | False | 12557.56 | 0 | 2983509 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch
| Each | 293.82 | 293.82 | 10.0 | False | None | None | False | None | False | 2938.2 | 0 | 2983510 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Bell Push
| Each | 187.62 | 187.62 | 16.0 | False | None | None | False | None | False | 3001.92 | 0 | 2983511 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket
| Each | 293.82 | 293.82 | 10.0 | False | None | None | False | None | False | 2938.2 | 0 | 2983512 | 98967 | None | ELE SR NO 2021-22 Item No 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV
| Each | 173.46 | 173.46 | 1.0 | False | None | None | False | None | False | 173.46 | 0 | 2983513 | 98967 | None | EL SR No 2021-22 Item No 12.21 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote Ding Dong Bell
| Each | 282.02 | 282.02 | 16.0 | False | None | None | False | None | False | 4512.32 | 0 | 2983514 | 98967 | None | EL SR No 2021-22 Item No 3.8 | Supplying 4mm thick plastic sheet with necessary nitches
for fixing switches, regulators etc, and fixing on existing
wooden or metal box using N.F. screws.
| Sq CM | 0.32 | 0.32 | 3500.0 | False | None | None | False | None | False | 1120.0 | 0 | 2983515 | 98967 | None | ELE SR NO 2021-22 Item No 3.9 | Supplying and fixing hylum plastic sheet 3mm thick with
necessary nitches for fixing switches, regulators etc., and
fixing on existing wood or metal box using N. F. screws. | Sq CM | 0.28 | 0.28 | 3500.0 | False | None | None | False | None | False | 980.0 | 0 | 2983516 | 98967 | None | ELE SR NO 2021-22 Item No 3.11 | Supplying 50mm wooden plug, tapered from 50x50mm to 25x25mm and fixing by using binding wire before concreting a roof slab.
| Each | 9.44 | 9.44 | 350.0 | False | None | None | False | None | False | 3304.0 | 0 | 2983517 | 98967 | None | ELE SR NO 2021-22 Item No 3.14.5 | Supplying and fixing/replacing of 6/16/32Amps electrical
accessories on existing switch board.6Amps Bakelite ceiling rose(KPWD ELE SR 2022-23,P.NO 6,3.14.5) | No | 74.34 | 74.34 | 40.0 | False | None | None | False | None | False | 2973.6 | 0 | 2983518 | 98967 | None | ELE SR NO 2021-22 Item No 3.14.6 | Supplying and fixing/replacing of 6/16/32Amps electrical
accessories on existing switch board.6 Amps lamp holder.(KPWD ELE SR 2022-23,P.NO 6,3.14.6) | No | 74.34 | 74.34 | 100.0 | False | None | None | False | None | False | 7434.0 | 0 | 2983519 | 98967 | None | ELE SR NO 2021-22 Item No 5.14.8 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 125 A 25 kA.
| No | 11884.96 | 11884.96 | 1.0 | False | None | None | False | None | False | 11884.96 | 0 | 2983520 | 98967 | None | ELE SR NO 2021-22 Item No 5.15 | Supplying and fixing of Shunt trip suitable for MCCB Cbct | No | 1784.16 | 1784.16 | 1.0 | False | None | None | False | None | False | 1784.16 | 0 | 2983521 | 98967 | None | ELE SR NO 2021-22 Item No 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP.
| No | 617.14 | 617.14 | 64.0 | False | None | None | False | None | False | 39496.96 | 0 | 2983522 | 98967 | None | ELE SR NO 2021-22 Item No 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP.
| No | 1301.54 | 1301.54 | 5.0 | False | None | None | False | None | False | 6507.7 | 0 | 2983523 | 98967 | None | ELE SR NO 2021-22 Item No 5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN.
| No | 2830.82 | 2830.82 | 6.0 | False | None | None | False | None | False | 16984.92 | 0 | 2983524 | 98967 | None | ELE SR NO 2021-22 Item No 5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N
| No | 2439.06 | 2439.06 | 1.0 | False | None | None | False | None | False | 2439.06 | 0 | 2983525 | 98967 | None | ELE SR NO 2021-22 Item No 5.18.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 6 Way TP & N
| No | 4407.3 | 4407.3 | 3.0 | False | None | None | False | None | False | 13221.9 | 0 | 2983526 | 98967 | None | ELE SR NO 2021-22 Item No 5.19.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 16A-25A 2 pole.
| No | 5366.64 | 5366.64 | 1.0 | False | None | None | False | None | False | 5366.64 | 0 | 2983527 | 98967 | None | ELE SR NO 2021-22 Item No 5.19.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole.
| No | 5946.02 | 5946.02 | 3.0 | False | None | None | False | None | False | 17838.06 | 0 | 2983528 | 98967 | None | ELE SR NO 2021-22 Item No 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.(KPWD ELE SR 2022-23,P.No.14, I.No.5.21)
| No | 9812.88 | 9812.88 | 2.0 | False | None | None | False | None | False | 19625.76 | 0 | 2983529 | 98967 | None | ELE SR NO 2021-22 Item No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter.
| No | 1510.4 | 1510.4 | 2.0 | False | None | None | False | None | False | 3020.8 | 0 | 2983530 | 98967 | None | ELE SR NO 2021-22 Item No 5.31 | Supplying and fixing Electronic Trivector Meter (ETV)
suitable for operation LT operation and -CT operated meter in
polycarbonate body in class 0.5 accuracy as per IS 14697 and
completely wired.
| Each | 4651.56 | 4651.56 | 1.0 | False | None | None | False | None | False | 4651.56 | 0 | 2983531 | 98967 | None | ELE SR NO 2021-22 Item No 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy.
| No | 9876.6 | 9876.6 | 2.0 | False | None | None | False | None | False | 19753.2 | 0 | 2983532 | 98967 | None | ELE SR NO 2021-22 Item No 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound.
| No | 595.9 | 595.9 | 6.0 | False | None | None | False | None | False | 3575.4 | 0 | 2983533 | 98967 | None | ELE SR NO 2021-22 Item No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C.
| No | 547.52 | 547.52 | 24.0 | False | None | None | False | None | False | 13140.48 | 0 | 2983534 | 98967 | None | ELE SR NO 2021-22 Item No 5.40.1 | Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips.
| m | 2612.52 | 2612.52 | 4.0 | False | None | None | False | None | False | 10450.08 | 0 | 2983535 | 98967 | None | ELE SR NO 2021-22 Item No 5.40.2 | Supplying . amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips.
| m | 3632.04 | 3632.04 | 6.0 | False | None | None | False | None | False | 21792.24 | 0 | 2983536 | 98967 | None | ELE SR NO 2021-22 Item No 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm
| m | 420.08 | 420.08 | 12.0 | False | None | None | False | None | False | 5040.96 | 0 | 2983537 | 98967 | None | ELE SR NO 2021-22 Item No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mm
| m | 324.5 | 324.5 | 12.0 | False | None | None | False | None | False | 3894.0 | 0 | 2983538 | 98967 | None | ELE SR NO 2021-22 Item No 5.41.4 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel
| m | 802.4 | 802.4 | 12.0 | False | None | None | False | None | False | 9628.8 | 0 | 2983539 | 98967 | None | ELE SR NO 2021-22 Item No 5.13.2 | Supplying and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 40Amps.
| No | 2508.68 | 2508.68 | 3.0 | False | None | None | False | None | False | 7526.04 | 0 | 2983540 | 98967 | None | ELE SR NO 2021-22 Item No 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor.
| Kvar | 509.76 | 509.76 | 15.0 | False | None | None | False | None | False | 7646.4 | 0 | 2983541 | 98967 | None | EL SR No 2021-22 Item No 5.38 | Supplying fixing and wiring Automatic Power Factor controller circuit unit fully static units controlled by 14 stage microprocessor operation relays LED display self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank measurement of network harmonics with indication when limit values are exceeded Comprehensive displays with large three phase LED display Long term memory for settings protection for over voltage power factor correction fault and no voltage to connect disconnect banks with automatic recognition or with standard programs
| No | 22939.2 | 22939.2 | 1.0 | False | None | None | False | None | False | 22939.2 | 0 | 2983542 | 98967 | None | ELE SR NO 2021-22 Item No 5.42.1 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 14SWG .
| Sq CM | 0.51 | 0.51 | 225000.0 | False | None | None | False | None | False | 114750.0 | 0 | 2983543 | 98967 | None | ELE SR NO 2021-22 Item No 6.2 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| No | 4897.0 | 4897.0 | 4.0 | False | None | None | False | None | False | 19588.0 | 0 | 2983544 | 98967 | None | ELE SR NO 2021-22 Item No 6.3.1 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.GI Strip. 25x3mm.
| m | 88.5 | 88.5 | 10.0 | False | None | None | False | None | False | 885.0 | 0 | 2983545 | 98967 | None | ELE SR NO 2021-22 Item No 6.3.4 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.50x6mm GI strip.
| m | 230.1 | 230.1 | 10.0 | False | None | None | False | None | False | 2301.0 | 0 | 2983546 | 98967 | None | ELE SR NO 2021-22 Item No 6.3.6 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Copper strip. 25x3mm.
| m | 595.9 | 595.9 | 10.0 | False | None | None | False | None | False | 5959.0 | 0 | 2983547 | 98967 | None | ELE SR NO 2021-22 Item No 6.3.7 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Copper strip. 25x6mm.
| m | 1130.44 | 1130.44 | 10.0 | False | None | None | False | None | False | 11304.4 | 0 | 2983548 | 98967 | None | ELE SR NO 2021-22 Item No 6.3.10 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.600x600x3mm Copper plate.
| No | 8142.0 | 8142.0 | 4.0 | False | None | None | False | None | False | 32568.0 | 0 | 2983549 | 98967 | None | ELE SR NO 2021-22 Item No 6.18.4 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire.
| m | 68.44 | 68.44 | 50.0 | False | None | None | False | None | False | 3422.0 | 0 | 2983550 | 98967 | None | ELE SR NO 2021-22 Item No 6.17.1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5sqmm
| No | 3.54 | 3.54 | 50.0 | False | None | None | False | None | False | 177.0 | 0 | 2983551 | 98967 | None | ELE SR NO 2021-22 Item No 6.17.2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm
| No | 4.72 | 4.72 | 115.0 | False | None | None | False | None | False | 542.8 | 0 | 2983552 | 98967 | None | ELE SR NO 2021-22 Item No 6.17.3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm
| No | 8.26 | 8.26 | 30.0 | False | None | None | False | None | False | 247.8 | 0 | 2983553 | 98967 | None | ELE SR NO 2021-22 Item No 6.17.4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sqmm
| No | 8.26 | 8.26 | 10.0 | False | None | None | False | None | False | 82.6 | 0 | 2983554 | 98967 | None | EL SR No 2021-22 Item No 6.17.5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10 sqm
| No | 9.44 | 9.44 | 24.0 | False | None | None | False | None | False | 226.56 | 0 | 2983555 | 98967 | None | ELE SR NO 2021-22 Item No 6.8 | Providing and laying in position 100mm dia stone ware pipe in existing trench.
| Mtr | 253.7 | 253.7 | 50.0 | False | None | None | False | None | False | 12685.0 | 0 | 2983556 | 98967 | None | ELE SR NO 2021-22 Item No 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 15" Sweep (450mm)
| No | 1819.56 | 1819.56 | 13.0 | False | None | None | False | None | False | 23654.28 | 0 | 2983557 | 98967 | None | ELE SR NO 2021-22 Item No 6.4.1 | supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374 / 79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W plus/minus 10% , Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 plus/minus 10% RPM, Rated air delivery 210 plus/minus 10% Cubic Meter Minimum, Rated service value more 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200mm)than | No | 3479.82 | 3479.82 | 24.0 | False | None | None | False | None | False | 83515.68 | 0 | 2983558 | 98967 | None | ELE SR NO 2021-22 Item No 11.3.1 | Supplying of feet - PVC Batten with integrated LED tube. W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x 2' - 9/10w | No | 585.28 | 585.28 | 20.0 | False | None | None | False | None | False | 11705.6 | 0 | 2983559 | 98967 | None | ELE SR NO 2021-22 Item No 11.3.2 | Supplying of .feet - PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | No | 873.2 | 873.2 | 104.0 | False | None | None | False | None | False | 90812.8 | 0 | 2983560 | 98967 | None | ELE SR NO 2021-22 Item No 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 985.3 | 985.3 | 51.0 | False | None | None | False | None | False | 50250.3 | 0 | 2983561 | 98967 | None | ELE SR NO 2021-22 Item No 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1473.82 | 1473.82 | 4.0 | False | None | None | False | None | False | 5895.28 | 0 | 2983562 | 98967 | None | ELE SR NO 2021-22 Item No 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K | Each | 279.66 | 279.66 | 10.0 | False | None | None | False | None | False | 2796.6 | 0 | 2983563 | 98967 | None | ELE SR NO 2021-22 Item No 6.5.1 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.300mm Sweep
| Each | 3124.64 | 3124.64 | 1.0 | False | None | None | False | None | False | 3124.64 | 0 | 2983564 | 98967 | None | ELE SR NO 2021-22 Item No 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders
| Each | 140.42 | 140.42 | 179.0 | False | None | None | False | None | False | 25135.18 | 0 | 2983565 | 98967 | None | ELE SR NO 2021-22 Item No 13.11 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.
| Each | 331.58 | 331.58 | 35.0 | False | None | None | False | None | False | 11605.3 | 0 | 2983566 | 98967 | None | ELE SR NO 2021-22 Item No 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.
| Each | 828.36 | 828.36 | 13.0 | False | None | None | False | None | False | 10768.68 | 0 | 2983567 | 98967 | None | ELE SR NO 2021-22 Item No 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT more than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire more than IK08. Power Factor more than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with .W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osram make LED Source. LED Streetlight 40W | No | 4308.18 | 4308.18 | 4.0 | False | None | None | False | None | False | 17232.72 | 0 | 2983568 | 98967 | None | ELE SR NO 2021-22 Item No 13.2.1 | Supplying and Fixing.mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed forfixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe
| No | 1239.0 | 1239.0 | 4.0 | False | None | None | False | None | False | 4956.0 | 0 | 2983569 | 98967 | None | ELE SR NO 2021-22 Item No 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires
| No | 223.02 | 223.02 | 4.0 | False | None | None | False | None | False | 892.08 | 0 | 2983570 | 98967 | None | ELE SR NO 2021-22 Item No 7.11 | Supplying .litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 10 L.
| Each | 7646.4 | 7646.4 | 5.0 | False | None | None | False | None | False | 38232.0 | 0 | 2983571 | 98967 | None | ELE SR NO 2021-22 Item No 9.2.5 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 300 L.
| Each | 83525.12 | 83525.12 | 1.0 | False | None | None | False | None | False | 83525.12 | 0 | 2983572 | 98967 | None | ELE SR NO 2021-22 Item No 9.2.5 | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS(KPWD ELE SR 2022-23,P.No. 29, I.No.9.2.5)
| Each | 45619.98 | 45619.98 | 1.0 | False | None | None | False | None | False | 45619.98 | 0 | 2983573 | 98967 | None | ELE SR NO 2021-22 Item No 9.5.6 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries80 AH capacity.(KPWD ELE SR 2022-23,P.No. 29, I.No.9.5.6)
| Each | 12682.64 | 12682.64 | 6.0 | False | None | None | False | None | False | 76095.84 | 0 | 2983574 | 98967 | None | BESCOM SR PART-3,P.NO-9,It no-.32.14 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.150 Sqmm, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)
| Km | 606567.2 | 606567.2 | 0.4 | False | None | None | False | None | False | 242626.88 | 0 | 2983575 | 98967 | None | BESCOM SR PART-4,P.NO-9,It no-.31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.35 to 95 Sqmm
| Km | 27903.46 | 27903.46 | 0.4 | False | None | None | False | None | False | 11161.384 | 0 | 2983576 | 98967 | None | BESCOM SR PART-3,P.NO-20,It no-.63.01 | Heavy Duty Copper Terminal Long Barrel.25 Sqmm Copper Terminal, Apprx Wt: 11 Gm.
| No | 34.22 | 34.22 | 8.0 | False | None | None | False | None | False | 273.76 | 0 | 2983577 | 98967 | None | BESCOM SR PART-3,P.NO-21,It no-.63.5 | Heavy Duty Copper Terminal Long Barrel.150 Sqmm Copper Terminal, Apprx Wt: 98 Gm
| No | 156.94 | 156.94 | 8.0 | False | None | None | False | None | False | 1255.52 | 0 | 2983578 | 98967 | None | BESCOM SR PART-3,P.NO-25,It no-.70.01 | Brass Cable Gland 25mm.
| No | 90.86 | 90.86 | 2.0 | False | None | None | False | None | False | 181.72 | 0 | 2983579 | 98967 | None | BESCOM SR PART-3,P.NO-25,It no-.70.02 | Brass Cable Gland 32mm.
| No | 109.74 | 109.74 | 2.0 | False | None | None | False | None | False | 219.48 | 0 | 2983580 | 98967 | None | BESCOM SR PART-3,P.NO-25,It no-.70.03 | Brass Cable Gland 40mm.
| No | 169.92 | 169.92 | 2.0 | False | None | None | False | None | False | 339.84 | 0 | 2983581 | 98967 | None | BESCOM SR PART-3P NO-25It no 70.04 | Brass Cable Gland 45mm
| No | 226.56 | 226.56 | 2.0 | False | None | None | False | None | False | 453.12 | 0 | 2983582 | 98967 | None | SR PART 3 P No15 INo 48.08 | PVC Pipe as per IS2509 PVC Pipe 80 mm Dia
| m | 264.32 | 264.32 | 10.0 | False | None | None | False | None | False | 2643.2 | 0 | 2983583 | 98967 | None | PART 4 P No 8 item no 29.02 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr Width and Depth upto 1 Mtr including trial pits depositing on bank upto a lead of 50 Mtr Supplying and Displaying necessary Danger Boards and Lighting Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil
| CUBIC METER | 306.8 | 306.8 | 75.0 | False | None | None | False | None | False | 23010.0 | 0 | 2983584 | 98967 | None | SR Part-4 P.NO.8 IT No-29.07 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr
| CUBIC METER | 68.44 | 68.44 | 75.0 | False | None | None | False | None | False | 5133.0 | 0 | 2983585 | 98967 | None | ELE SR NO 2021-22 Item No 5.11.3 | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution).125 A
| Each | 10793.46 | 10793.46 | 1.0 | False | None | None | False | None | False | 10793.46 | 0 |
| 1710137476000 | 0 | None | None | Buildings | DG Set | 1065250.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983586 | 98968 | None | ELE SR NO 2021-22, 10.1.7 | Supplying, installing, testing and commissioning of PRIME Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514 / ISO 3046 / ISO 8528 & IS 1002 / ISO 3046 Generator set specifications
Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor
12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spin-on lube oil filter, Spin-on dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade),Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, Permissible overload of 10% for one hour in 12 hours of operation "
Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming toIS/IEC 60034-1. The alternator shall have +1.0 % Voltage regulation (max) in static conditions- IP: 23 protections with insulation class H
Control Panel: The control panel is manufactured with 14/16 gauge CRCA sheet and is powder coated for weather-proof and long lasting finish. The control panel consists of the following parts:- PS0500 Controller, Aluminium bus bars with suitable capacity within/outgoing terminals, Indicating lamps for ‘Load On’ and ‘Set Running’, Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections.
Genset Controller: microprocessor based generator set monitoring and control system. The control provides a simple operator interface to the generator set, manual and remote start/ stop control, shutdown fault indication, and an LCD hour counter. The integration of all functions into a single control system provides enhanced reliability and performance compared to conventional generator set control systems. This control has been designed and tested to meet harsh environment in which gensets are typically applied. Features, Functions, protections 16 character x 2 line alphanumeric LCD display with LED Backlight.
Voltage (1 ph or 3 ph line to line and line to neutral voltage, Current (1 ph or 3 ph), kVA (3 ph and total), Frequency, Provide Engine Data, Starting
battery voltage, Engine running hours, Engine Temp, Engine oil pressure, Control includes provision for Service adjustment and calibration of DG control functions, Voltage, frequency selection, Configurable input and output set up, Meter calibration, Engine controls, Power Start operates on 12 VDC batteries,- Auto start mode accepts a ground signal from remote devices to automatically start the DG set. The remote start will also wake up the control system from sleep mode.Acoustic enclosure: The acoustic enclosure shall be made of 1.6 mm thick CRCA sheets in suitable approved shade and a structural/ sheet metal base frame painted in black. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75dBA at 1 mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: Specially designed to meet stringent MOEF/ CPCB norms of 75dBA @ 1mtr at 75% load under free field conditions, Two point lifting for easy handling at customer site, Designed to have optimum serviceability, Air inlet louvers specially designed to operate at rated load made on special purpose CNC machines for consistency in quality and workmanship, Powder coated for long lasting service life and superior finish, With UV resistant powder coating, can withstand extreme environment,Use of special hardware for longer life, Insulation material meets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. 62.5 kVA/50kW
| Set | 729930.3 | 729930.3 | 1.0 | False | None | None | False | None | False | 729930.3 | 0 | 2983587 | 98968 | None | ELE SR 2021-22, 10.2.1 | Supply, Erection, testing and commissioning of AMF panel suitable for .kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .A 4 pole contactor for alternator with thermal O/L relay,. A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, .capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.
Upto 62.50 KVA
| Set | 89562.0 | 89562.0 | 1.0 | False | None | None | False | None | False | 89562.0 | 0 | 2983588 | 98968 | None | 15.104, fire fighting | Supply, Installation testing and commissioning of approved make heavy quantity (Class 'C') confirming to as per IS1239 Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. do- 150 mm dia. | m | 5546.0 | 5546.0 | 32.0 | False | None | None | False | None | False | 177472.0 | 0 | 2983589 | 98968 | None | SR 19-20-6.2 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrodeshall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| No | 4897.0 | 4897.0 | 4.0 | False | None | None | False | None | False | 19588.0 | 0 | 2983590 | 98968 | None | SR 19-20-6.18.6 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23)
8 SWG-Cu Wire
| m | 123.9 | 123.9 | 20.0 | False | None | None | False | None | False | 2478.0 | 0 | 2983591 | 98968 | None | SR 19-20-6.3.4 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
50x6mm GI strip
| m | 188.8 | 188.8 | 15.0 | False | None | None | False | None | False | 2832.0 | 0 | 2983592 | 98968 | None | SR 19-20-6.3.5 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm GI Plate
| Each | 896.8 | 896.8 | 2.0 | False | None | None | False | None | False | 1793.6 | 0 | 2983593 | 98968 | None | SR 19-20-6.3.8 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
40x6mm Copper strip
| m | 1687.4 | 1687.4 | 15.0 | False | None | None | False | None | False | 25311.0 | 0 | 2983594 | 98968 | None | SR 19-20-6.3.10 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.
600x600x3mm Copper plate
| Each | 8142.0 | 8142.0 | 2.0 | False | None | None | False | None | False | 16284.0 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Girls Hostel-Civil work-Upto plinth level | 5464593.23 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983595 | 98969 | None | PWD Volume-3 SR2021-22 Page No7 Item No2.5A | Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.
(ii) By Mechanical Means using Dozer
A. In area of light jungle | ha | 195816.52 | 195816.52 | 0.0423 | False | None | None | False | None | False | 8283.038796 | 0 | 2983596 | 98969 | None | PWD Volume-1 SR2021-22 Page No 8 Item No1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 80.54 | 80.54 | 126.89 | False | None | None | False | None | False | 10219.7206 | 0 | 2983597 | 98969 | None | PWD Volume-1 SR2021-22 Page No 8 Item No1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 93.03 | 93.03 | 467.96 | False | None | None | False | None | False | 43534.3188 | 0 | 2983598 | 98969 | None | PWD Volume-1 SR2021-22 Page No 9 Item No1.16.1 | In Hard Rock ( requiring blasting) Depth upto 1.50m | Cum | 519.14 | 519.14 | 9.35 | False | None | None | False | None | False | 4853.959 | 0 | 2983599 | 98969 | None | PWD Volume-1 SR2021-22 Page No 15 Item No2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6881.41 | 6881.41 | 55.88 | False | None | None | False | None | False | 384533.1908 | 0 | 2983600 | 98969 | None | PWD Volume-2 SR2021-22 Page No 9 Item No5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6717.86 | 6717.86 | 24.6375 | False | None | None | False | None | False | 165511.27575 | 0 | 2983601 | 98969 | None | PWD Volume-1 SR2021-22 Page No 15 Item No2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates All round Building | Cum | 6881.41 | 6881.41 | 8.7612 | False | None | None | False | None | False | 60289.409292 | 0 | 2983602 | 98969 | None | PWD Volume-2 SR2021-22 Page No 5 Item No4.1 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. All round Building | Sqm | 117.71 | 117.71 | 423.0 | False | None | None | False | None | False | 49791.33 | 0 | 2983603 | 98969 | None | PWD Volume-1 SR2021-22 Page No 7 Item No1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 252.76 | 252.76 | 467.96 | False | None | None | False | None | False | 118281.5696 | 0 | 2983604 | 98969 | None | PWD Volume-3 SR2021-22 Page No 3 Item No1.01A | Loading and Unloading of Stone Boulder/Stone aggregates/ Sand/Kankar/Moorum.
(Tipper 5.5 m3) | Cum | 146.2 | 146.2 | 477.32 | False | None | None | False | None | False | 69784.184 | 0 | 2983605 | 98969 | None | PWD Volume-3 SR2021-22 Page No 3 Item No1.04(i)A | Cost of Haulage Excluding Loading and Unloading Taking output 10 t load and lead 10 km = 100 t.km | T.Km | 14.87 | 14.87 | 763.72 | False | None | None | False | None | False | 11356.5164 | 0 | 2983606 | 98969 | None | PWD Volume-1 SR2021-22 Page No 7 Item No1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,
grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Required soil for filing | Cum | 498.08 | 498.08 | 8.99 | False | None | None | False | None | False | 4477.7392 | 0 | 2983607 | 98969 | None | PWD Volume-1 SR2021-22 Page No 15 Issue rate 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7407.98 | 7407.98 | 161.16 | False | None | None | False | None | False | 1193870.0568 | 0 | 2983608 | 98969 | None | PWD Volume-1 SR2021-22 Page No 16 Issue rate 2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7411.7 | 7411.7 | 4.3956 | False | None | None | False | None | False | 32578.86852 | 0 | 2983609 | 98969 | None | PWD Volume-1 SR2021-22 Page No 17 Issue rate 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7424.09 | 7424.09 | 13.12 | False | None | None | False | None | False | 97404.0608 | 0 | 2983610 | 98969 | None | PWD Volume-1 SR2021-22 Page No 17 ssue rates 2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS C M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7411.7 | 7411.7 | 36.94 | False | None | None | False | None | False | 273788.198 | 0 | 2983611 | 98969 | None | PWD Volume-2 SR2021-22 Page No 84Item No11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 113.99 | 113.99 | 23339.59 | False | None | None | False | None | False | 2660479.8641 | 0 | 2983612 | 98969 | None | PWD Volume-1 SR2021-22 Page No 115 Item No1 | Foundation upto Plinth a. Isolated | Sqm | 592.64 | 592.64 | 48.903 | False | None | None | False | None | False | 28981.87392 | 0 | 2983613 | 98969 | None | PWD Volume-1 SR2021-22 Page No 115 Item No1 | Isolated Footing b. All other types | Sqm | 222.24 | 222.24 | 85.55 | False | None | None | False | None | False | 19012.632 | 0 | 2983614 | 98969 | None | PWD Volume-1 SR2021-22 Page No 115 Item No2 | Foundation, Sub structure of Cross drainages | Sqm | 344.07 | 344.07 | 55.88 | False | None | None | False | None | False | 19226.6316 | 0 | 2983615 | 98969 | None | PWD Volume-1 SR2021-22 Page No 2 Item No8 | Columns | Sqm | 5196.86 | 5196.86 | 13.12 | False | None | None | False | None | False | 68182.8032 | 0 | 2983616 | 98969 | None | PWD Volume-1 SR2021-22 Page No 115 Item No9 | Earth retaining structures | Sqm | 741.17 | 741.17 | 4.3956 | False | None | None | False | None | False | 3257.886852 | 0 | 2983617 | 98969 | None | PWD Volume-1 SR2021-22 Page No 2 Item No1a | Plinth Beams of Buildings (50%) | Sqm | 3705.85 | 3705.85 | 36.94 | False | None | None | False | None | False | 136894.099 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Girls Hostel-Civil work-Above plinth level | 14254626.84 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983618 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Lintels GROUND FLOOR | Cum | 7664.45 | 7664.45 | 1.8056 | False | None | None | False | None | False | 13838.93092 | 0 | 2983619 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Lintels FIRST FLOOR | Cum | 7741.1 | 7741.1 | 6.09 | False | None | None | False | None | False | 47143.299 | 0 | 2983620 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Lintels SECOND FLOOR | Cum | 7817.74 | 7817.74 | 6.09 | False | None | None | False | None | False | 47610.0366 | 0 | 2983621 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Lintels TERRACE FLOOR | Cum | 7894.39 | 7894.39 | 3.65 | False | None | None | False | None | False | 28814.5235 | 0 | 2983622 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Cill GROUND FLOOR | Cum | 7664.45 | 7664.45 | 0.06 | False | None | None | False | None | False | 459.867 | 0 | 2983623 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Cill FIRST FLOOR | Cum | 7741.1 | 7741.1 | 0.49 | False | None | None | False | None | False | 3793.139 | 0 | 2983624 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Cill SECOND FLOOR | Cum | 7817.74 | 7817.74 | 0.49 | False | None | None | False | None | False | 3830.6926 | 0 | 2983625 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Staircase GROUND FLOOR | Cum | 7664.45 | 7664.45 | 3.435 | False | None | None | False | None | False | 26327.38575 | 0 | 2983626 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Staircase FIRST FLOOR | Cum | 7741.1 | 7741.1 | 3.435 | False | None | None | False | None | False | 26590.6785 | 0 | 2983627 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RCC Staircase SECOND FLOOR | Cum | 7817.74 | 7817.74 | 3.495 | False | None | None | False | None | False | 27323.0013 | 0 | 2983628 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plain Chejja GROUND FLOOR | Cum | 7664.45 | 7664.45 | 0.81 | False | None | None | False | None | False | 6208.2045 | 0 | 2983629 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plain Chejja FIRST FLOOR | Cum | 7741.1 | 7741.1 | 1.49 | False | None | None | False | None | False | 11534.239 | 0 | 2983630 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plain Chejja SECOND FLOOR | Cum | 7817.74 | 7817.74 | 1.49 | False | None | None | False | None | False | 11648.4326 | 0 | 2983631 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof slab GROUND FLOOR | Cum | 7664.45 | 7664.45 | 31.629 | False | None | None | False | None | False | 242418.88905 | 0 | 2983632 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof slab FIRST FLOOR | Cum | 7741.1 | 7741.1 | 30.52 | False | None | None | False | None | False | 236258.372 | 0 | 2983633 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof slab SECOND FLOOR | Cum | 7817.74 | 7817.74 | 30.52 | False | None | None | False | None | False | 238597.4248 | 0 | 2983634 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof slab TERRACE FLOOR | Cum | 7894.39 | 7894.39 | 9.135 | False | None | None | False | None | False | 72115.25265 | 0 | 2983635 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Beam GROUND FLOOR | Cum | 7664.45 | 7664.45 | 15.17 | False | None | None | False | None | False | 116269.7065 | 0 | 2983636 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Beam FIRST FLOOR | Cum | 7741.1 | 7741.1 | 15.17 | False | None | None | False | None | False | 117432.487 | 0 | 2983637 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Beam SECOND FLOOR | Cum | 7817.74 | 7817.74 | 15.17 | False | None | None | False | None | False | 118595.1158 | 0 | 2983638 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Beam TERRACE FLOOR | Cum | 7894.39 | 7894.39 | 3.32 | False | None | None | False | None | False | 26209.3748 | 0 | 2983639 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C. column GROUND FLOOR | Cum | 7664.45 | 7664.45 | 13.85 | False | None | None | False | None | False | 106152.6325 | 0 | 2983640 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C. column FIRST FLOOR | Cum | 7741.1 | 7741.1 | 13.85 | False | None | None | False | None | False | 107214.235 | 0 | 2983641 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C. column SECOND FLOOR | Cum | 7817.74 | 7817.74 | 13.85 | False | None | None | False | None | False | 108275.699 | 0 | 2983642 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C.Wall GROUND FLOOR | Cum | 7664.45 | 7664.45 | 6.66 | False | None | None | False | None | False | 51045.237 | 0 | 2983643 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C.Wall FIRST FLOOR | Cum | 7741.1 | 7741.1 | 6.66 | False | None | None | False | None | False | 51555.726 | 0 | 2983644 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C.Wall SECOND FLOOR | Cum | 7817.74 | 7817.74 | 6.66 | False | None | None | False | None | False | 52066.1484 | 0 | 2983645 | 98970 | None | PWD 21-22 SR V-3 SR 2021-22 Page No-17 It No-2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates R.C.C.Wall TERRACE FLOOR | Cum | 7894.39 | 7894.39 | 13.8665 | False | None | None | False | None | False | 109467.558935 | 0 | 2983646 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-8 | centering for columns - Columns 70% Columns Qty GROUND FLOOR | Sqm | 5365.12 | 5365.12 | 13.85 | False | None | None | False | None | False | 74306.912 | 0 | 2983647 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-8 | centering for columns - Columns 70% Columns Qty FIRST FLOOR | Sqm | 5418.77 | 5418.77 | 13.85 | False | None | None | False | None | False | 75049.9645 | 0 | 2983648 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-8 | centering for columns - Columns 70% Columns Qty SECOND FLOOR | Sqm | 5472.42 | 5472.42 | 13.85 | False | None | None | False | None | False | 75793.017 | 0 | 2983649 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-8 | centering for columns - Columns 70% Columns Qty TERRACE FLOOR | Sqm | 5526.07 | 5526.07 | 8.208 | False | None | None | False | None | False | 45357.98256 | 0 | 2983650 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-115 It No-9 | centering for columns - Columns 70% Rcc wall GROUND FLOOR | Sqm | 766.45 | 766.45 | 6.66 | False | None | None | False | None | False | 5104.557 | 0 | 2983651 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-115 It No-9 | centering for columns - Columns 70% Rcc wall FIRST FLOOR | Sqm | 774.11 | 774.11 | 6.66 | False | None | None | False | None | False | 5155.5726 | 0 | 2983652 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-115 It No-9 | centering for columns - Columns 70% Rcc wall SECOND FLOOR | Sqm | 781.77 | 781.77 | 6.66 | False | None | None | False | None | False | 5206.5882 | 0 | 2983653 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-115 It No-9 | centering for columns - Columns 70% Rcc wall TERRACE FLOOR | Sqm | 789.44 | 789.44 | 13.8665 | False | None | None | False | None | False | 10946.76976 | 0 | 2983654 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) BEAM GROUND FLOOR | Sqm | 4598.67 | 4598.67 | 15.17 | False | None | None | False | None | False | 69761.8239 | 0 | 2983655 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) BEAM FIRST FLOOR | Sqm | 4644.66 | 4644.66 | 15.17 | False | None | None | False | None | False | 70459.4922 | 0 | 2983656 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) BEAM SECOND FLOOR | Sqm | 4690.65 | 4690.65 | 15.17 | False | None | None | False | None | False | 71157.1605 | 0 | 2983657 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) BEAM TERRACE FLOOR | Sqm | 4736.63 | 4736.63 | 3.31 | False | None | None | False | None | False | 15678.2453 | 0 | 2983658 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) LINTEL GROUND FLOOR | Sqm | 4598.67 | 4598.67 | 1.8056 | False | None | None | False | None | False | 8303.358552 | 0 | 2983659 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) LINTEL FIRST FLOOR | Sqm | 4644.66 | 4644.66 | 6.09 | False | None | None | False | None | False | 28285.9794 | 0 | 2983660 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) LINTEL SECOND FLOOR | Sqm | 4690.65 | 4690.65 | 6.09 | False | None | None | False | None | False | 28566.0585 | 0 | 2983661 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-12 | Beams & Lintels of Building ( 60% ) LINTEL TERRACE FLOOR | Sqm | 4736.63 | 4736.63 | 3.65 | False | None | None | False | None | False | 17288.6995 | 0 | 2983662 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings (50%) Roof Slab Concrete Quantity GROUND FLOOR | Sqm | 3832.23 | 3832.23 | 31.629 | False | None | None | False | None | False | 121209.60267 | 0 | 2983663 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings Roof Slab Concrete Quantity(50%) FIRST FLOOR | Sqm | 3870.55 | 3870.55 | 30.52 | False | None | None | False | None | False | 118129.186 | 0 | 2983664 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings (50%)Roof Slab Concrete Quantity SECOND FLOOR | Sqm | 3908.87 | 3908.87 | 30.52 | False | None | None | False | None | False | 119298.7124 | 0 | 2983665 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings (50%) Roof Slab Concrete QuantityTERRACE FLOOR | Sqm | 3947.19 | 3947.19 | 9.135 | False | None | None | False | None | False | 36057.58065 | 0 | 2983666 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings (50%)Staricase Concrete QuanrityGROUND FLOOR | Sqm | 3832.23 | 3832.23 | 3.435 | False | None | None | False | None | False | 13163.71005 | 0 | 2983667 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings (50%)Staricase Concrete QuanrityFIRST FLOOR | Sqm | 3870.55 | 3870.55 | 3.435 | False | None | None | False | None | False | 13295.33925 | 0 | 2983668 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-2 It No-13&14 | Roof Slab of Buildings (50%)Staricase Concrete Quanrity SECOND FLOOR | Sqm | 3908.87 | 3908.87 | 3.495 | False | None | None | False | None | False | 13661.50065 | 0 | 2983669 | 98970 | None | PWD 21-22 SR V-1 SR 2021-22 Page No-116 It No-20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) Chejjas GROUND FLOOR | Sqm | 3449.0 | 3449.0 | 0.81 | False | None | None | False | None | False | 2793.69 | 0 | 2983670 | 98970 | None | PWD 21-22 SR V-1 SR 2021-22 Page No-116 It No-20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) Chejjas FIRST FLOOR | Sqm | 3483.49 | 3483.49 | 1.49 | False | None | None | False | None | False | 5190.4001 | 0 | 2983671 | 98970 | None | PWD 21-22 SR V-1 SR 2021-22 Page No-116 It No-20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) ChejjasSECOND FLOOR | Sqm | 3517.98 | 3517.98 | 1.49 | False | None | None | False | None | False | 5241.7902 | 0 | 2983672 | 98970 | None | PWD 21-22 SR V-1 SR 2021-22 Page No-116 It No-20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Cills GROUND FLOOR | Sqm | 3449.0 | 3449.0 | 0.06 | False | None | None | False | None | False | 206.94 | 0 | 2983673 | 98970 | None | PWD 21-22 SR V-1 SR 2021-22 Page No-116 It No-20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Cills FIRST FLOOR | Sqm | 3483.49 | 3483.49 | 0.49 | False | None | None | False | None | False | 1706.9101 | 0 | 2983674 | 98970 | None | PWD 21-22 SR V-1 SR 2021-22 Page No-116 It No-20 | Chejjas, Canopy & Other Architectural projections of minor sections ( 45% ) RCC Cills SECOND FLOOR | Sqm | 3517.98 | 3517.98 | 0.49 | False | None | None | False | None | False | 1723.8102 | 0 | 2983675 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-84 It No-11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) GROUND FLOOR | Kg | 113.99 | 113.99 | 9500.27 | False | None | None | False | None | False | 1082935.7773 | 0 | 2983676 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-84 It No-11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) FIRST FLOOR | Kg | 115.13 | 115.13 | 9779.74 | False | None | None | False | None | False | 1125941.4662 | 0 | 2983677 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-84 It No-11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) SECOND FLOOR | Kg | 116.27 | 116.27 | 9788.74 | False | None | None | False | None | False | 1138136.7998 | 0 | 2983678 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-84 It No-11.32 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) TERRACE FLOOR | Kg | 121.97 | 121.97 | 4798.75 | False | None | None | False | None | False | 585303.5375 | 0 | 2983679 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR | Sqm | 1481.84 | 1481.84 | 90.0945 | False | None | None | False | None | False | 133505.63388 | 0 | 2983680 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIRST FLOOR | Sqm | 1496.66 | 1496.66 | 310.56 | False | None | None | False | None | False | 464802.7296 | 0 | 2983681 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SECOND FLOOR | Sqm | 1511.48 | 1511.48 | 310.56 | False | None | None | False | None | False | 469405.2288 | 0 | 2983682 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 5.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. TERRACE FLOOR | Sqm | 1526.3 | 1526.3 | 116.868 | False | None | None | False | None | False | 178375.6284 | 0 | 2983683 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. GROUND FLOOR | Sqm | 1164.66 | 1164.66 | 7.8375 | False | None | None | False | None | False | 9128.02275 | 0 | 2983684 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. FIRST FLOOR | Sqm | 1176.31 | 1176.31 | 32.46 | False | None | None | False | None | False | 38183.0226 | 0 | 2983685 | 98970 | None | PWD 21-22 SR V-2 SR 2021-22 Page No-17 It No-6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. SECOND FLOOR | Sqm | 1187.95 | 1187.95 | 32.46 | False | None | None | False | None | False | 38560.857 | 0 | 2983686 | 98970 | None | PWD 21-22 SR V-2 2021-22 Page No-98 It No 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.GROUND FLOOR | Cum | 76326.12 | 76326.12 | 0.1375 | False | None | None | False | None | False | 10494.8415 | 0 | 2983687 | 98970 | None | PWD 21-22 SR V-2 Page No-98 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. FIRST FLOOR | Cum | 77089.38 | 77089.38 | 0.62 | False | None | None | False | None | False | 47795.4156 | 0 | 2983688 | 98970 | None | PWD 21-22 SR V-2 Page No-98 It No-12.13.1 | Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.SECOND FLOOR | Cum | 77852.64 | 77852.64 | 0.62 | False | None | None | False | None | False | 48268.6368 | 0 | 2983689 | 98970 | None | PWD 21-22 SR V-2 Page No-104 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.'-do- 35 mm thick both side commercialGROUND FLOOR | Sqm | 3647.62 | 3647.62 | 4.2 | False | None | None | False | None | False | 15320.004 | 0 | 2983690 | 98970 | None | PWD 21-22 SR V-2 Page No-104 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.'-do- 35 mm thick both side commercialFIRST FLOOR | Sqm | 3684.09 | 3684.09 | 18.9 | False | None | None | False | None | False | 69629.301 | 0 | 2983691 | 98970 | None | PWD 21-22 SR V-2 Page No-104 It No-12.57.6 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.'-do- 35 mm thick both side commercialSECOND FLOOR | Sqm | 3720.57 | 3720.57 | 18.9 | False | None | None | False | None | False | 70318.773 | 0 | 2983692 | 98970 | None | PWD 21-22 SR V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. GROUND FLOOR | No | 1834.96 | 1834.96 | 12.0 | False | None | None | False | None | False | 22019.52 | 0 | 2983693 | 98970 | None | PWD 21-22 SR V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.FIRST FLOOR | No | 1853.31 | 1853.31 | 54.0 | False | None | None | False | None | False | 100078.74 | 0 | 2983694 | 98970 | None | PWD 21-22 SR V-2 Page No-103 It No-12.51 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.SECOND FLOOR | No | 1871.66 | 1871.66 | 54.0 | False | None | None | False | None | False | 101069.64 | 0 | 2983695 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. GROUND FLOOR | No | 135.05 | 135.05 | 2.0 | False | None | None | False | None | False | 270.1 | 0 | 2983696 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. FIRST FLOOR | No | 136.4 | 136.4 | 9.0 | False | None | None | False | None | False | 1227.6 | 0 | 2983697 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.58 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. SECOND FLOOR | No | 137.75 | 137.75 | 9.0 | False | None | None | False | None | False | 1239.75 | 0 | 2983698 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. GROUND FLOOR | No | 1090.32 | 1090.32 | 2.0 | False | None | None | False | None | False | 2180.64 | 0 | 2983699 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. FIRST FLOOR | No | 1101.22 | 1101.22 | 9.0 | False | None | None | False | None | False | 9910.98 | 0 | 2983700 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. SECOND FLOOR | No | 1112.13 | 1112.13 | 9.0 | False | None | None | False | None | False | 10009.17 | 0 | 2983701 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. GROUND FLOOR | No | 1030.85 | 1030.85 | 2.0 | False | None | None | False | None | False | 2061.7 | 0 | 2983702 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. FIRST FLOOR | No | 1041.16 | 1041.16 | 9.0 | False | None | None | False | None | False | 9370.44 | 0 | 2983703 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. SECOND FLOOR | No | 1051.46 | 1051.46 | 9.0 | False | None | None | False | None | False | 9463.14 | 0 | 2983704 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete GROUND FLOOR | No | 216.83 | 216.83 | 4.0 | False | None | None | False | None | False | 867.32 | 0 | 2983705 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete FIRST FLOOR | No | 218.99 | 218.99 | 18.0 | False | None | None | False | None | False | 3941.82 | 0 | 2983706 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete SECOND FLOOR | No | 221.16 | 221.16 | 18.0 | False | None | None | False | None | False | 3980.88 | 0 | 2983707 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete GROUND FLOOR | No | 137.53 | 137.53 | 4.0 | False | None | None | False | None | False | 550.12 | 0 | 2983708 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete FIRST FLOOR | No | 138.9 | 138.9 | 18.0 | False | None | None | False | None | False | 2500.2 | 0 | 2983709 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete SECOND FLOOR | No | 140.28 | 140.28 | 18.0 | False | None | None | False | None | False | 2525.04 | 0 | 2983710 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms GROUND FLOOR | No | 58.23 | 58.23 | 2.0 | False | None | None | False | None | False | 116.46 | 0 | 2983711 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms FIRST FLOOR | No | 58.82 | 58.82 | 9.0 | False | None | None | False | None | False | 529.38 | 0 | 2983712 | 98970 | None | PWD 21-22 SR V-2 Page No-105 It No-12.64 | Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms SECOND FLOOR | No | 59.4 | 59.4 | 9.0 | False | None | None | False | None | False | 534.6 | 0 | 2983713 | 98970 | None | PWD 21-22 SR V-2 Page No-106 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary
screws etc. complete :125x85x5.5 mm (heavy type) GROUND FLOOR | No | 249.04 | 249.04 | 8.0 | False | None | None | False | None | False | 1992.32 | 0 | 2983714 | 98970 | None | PWD 21-22 SR V-2 Page No-106 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary
screws etc. complete :125x85x5.5 mm (heavy type) FIRST FLOOR | No | 251.53 | 251.53 | 36.0 | False | None | None | False | None | False | 9055.08 | 0 | 2983715 | 98970 | None | PWD 21-22 SR V-2 Page No-106 It No-12.75.1 | Providing and fixing bright finished brass butt hinges with necessary
screws etc. complete :125x85x5.5 mm (heavy type) SECOND FLOOR | No | 254.02 | 254.02 | 36.0 | False | None | None | False | None | False | 9144.72 | 0 | 2983716 | 98970 | None | PWD 21-22 SR V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmGROUND FLOOR | No | 261.43 | 261.43 | 2.0 | False | None | None | False | None | False | 522.86 | 0 | 2983717 | 98970 | None | PWD 21-22 SR V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mm FIRST FLOOR | No | 264.04 | 264.04 | 9.0 | False | None | None | False | None | False | 2376.36 | 0 | 2983718 | 98970 | None | PWD 21-22 SR V-2 Page No-107 It No-12.76.3 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :150x10mmSECOND FLOOR | No | 266.66 | 266.66 | 9.0 | False | None | None | False | None | False | 2399.94 | 0 | 2983719 | 98970 | None | PWD 21-22 SR V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmGROUND FLOOR | No | 37.17 | 37.17 | 8.0 | False | None | None | False | None | False | 297.36 | 0 | 2983720 | 98970 | None | PWD 21-22 SR V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mm FIRST FLOOR | No | 37.54 | 37.54 | 36.0 | False | None | None | False | None | False | 1351.44 | 0 | 2983721 | 98970 | None | PWD 21-22 SR V-2 Page No-69 It No-10.6.3 | Providing and fixing expansion hold fasteners on C.C. /R.C.C./Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. Fastener with threaded dia 12 mmSECOND FLOOR | No | 37.91 | 37.91 | 36.0 | False | None | None | False | None | False | 1364.76 | 0 | 2983722 | 98970 | None | PWD 21-22 SR V-2 - Page No-179 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications.GROUND FLOOR | Sqm | 621.98 | 621.98 | 0.78 | False | None | None | False | None | False | 485.1444 | 0 | 2983723 | 98970 | None | PWD 21-22 SR V-2 - Page No-179 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 628.2 | 628.2 | 3.51 | False | None | None | False | None | False | 2204.982 | 0 | 2983724 | 98970 | None | PWD 21-22 SR V-2 - Page No-179 It No-20.79 | Supplying and fixing new teak wood beads wherever necessary including cost of materials, labour, complete as per specifications. SECOND FLOOR | Sqm | 634.42 | 634.42 | 3.51 | False | None | None | False | None | False | 2226.8142 | 0 | 2983725 | 98970 | None | PWD 21-22 SR V-2 - Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) GROUND FLOOR | Sqm | 8970.36 | 8970.36 | 3.6 | False | None | None | False | None | False | 32293.296 | 0 | 2983726 | 98970 | None | PWD 21-22 SR V-2 - Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) FIRST FLOOR | Sqm | 9060.06 | 9060.06 | 21.96 | False | None | None | False | None | False | 198958.9176 | 0 | 2983727 | 98970 | None | PWD 21-22 SR V-2 - Page No-110 It No-12.9 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)SECOND FLOOR | Sqm | 9149.77 | 9149.77 | 21.96 | False | None | None | False | None | False | 200928.9492 | 0 | 2983728 | 98970 | None | PWD 21-22 SR V-2 - Page No-108 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6094.27 | 6094.27 | 3.6 | False | None | None | False | None | False | 21939.372 | 0 | 2983729 | 98970 | None | PWD 21-22 SR V-2 - Page No-108 It No-12.85 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)SECOND FLOOR | Sqm | 6154.61 | 6154.61 | 3.6 | False | None | None | False | None | False | 22156.596 | 0 | 2983730 | 98970 | None | PWD 21-22 SR V-2 - Page No-103 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. FIRST FLOOR | Sqm | 594.41 | 594.41 | 7.98 | False | None | None | False | None | False | 4743.3918 | 0 | 2983731 | 98970 | None | PWD 21-22 SR V-2 - Page No-103 It No-12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. SECOND FLOOR | Sqm | 600.3 | 600.3 | 7.98 | False | None | None | False | None | False | 4790.394 | 0 | 2983732 | 98970 | None | PWD 21-22 SR V-2 - Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelamFIRST FLOOR | Sqm | 4759.04 | 4759.04 | 7.98 | False | None | None | False | None | False | 37977.1392 | 0 | 2983733 | 98970 | None | PWD 21-22 SR V-2 - Page No-104 It No-12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.-do- with both side prelamSECOND FLOOR | Sqm | 4806.16 | 4806.16 | 7.98 | False | None | None | False | None | False | 38353.1568 | 0 | 2983734 | 98970 | None | PWD 21-22 SR V-2 - Page No-85 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingGROUND FLOOR | Kg | 179.66 | 179.66 | 89.99 | False | None | None | False | None | False | 16167.6034 | 0 | 2983735 | 98970 | None | PWD 21-22 SR V-2 - Page No-85 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingFIRST FLOOR | Kg | 183.25 | 183.25 | 648.0 | False | None | None | False | None | False | 118746.0 | 0 | 2983736 | 98970 | None | PWD 21-22 SR V-2 - Page No-85 It No-11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingSECOND FLOOR | Kg | 185.04 | 185.04 | 648.0 | False | None | None | False | None | False | 119905.92 | 0 | 2983737 | 98970 | None | PWD 21-22 SR V-2 - Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 45.84 | 45.84 | 3.6 | False | None | None | False | None | False | 165.024 | 0 | 2983738 | 98970 | None | PWD 21-22 SR V-2 - Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 46.3 | 46.3 | 25.92 | False | None | None | False | None | False | 1200.096 | 0 | 2983739 | 98970 | None | PWD 21-22 SR V-2 - Page No-47 It No-8.34.3 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 46.76 | 46.76 | 25.92 | False | None | None | False | None | False | 1212.0192 | 0 | 2983740 | 98970 | None | PWD 21-22 SR V-2 - Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 161.07 | 161.07 | 3.6 | False | None | None | False | None | False | 579.852 | 0 | 2983741 | 98970 | None | PWD 21-22 SR V-2 - Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 162.68 | 162.68 | 25.92 | False | None | None | False | None | False | 4216.6656 | 0 | 2983742 | 98970 | None | PWD 21-22 SR V-2 - Page No-48 It No-8.41 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 164.29 | 164.29 | 25.92 | False | None | None | False | None | False | 4258.3968 | 0 | 2983743 | 98970 | None | PWD 21-22 SR V-2 - Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. GROUND FLOOR | Sqm | 50.8 | 50.8 | 4.2 | False | None | None | False | None | False | 213.36 | 0 | 2983744 | 98970 | None | PWD 21-22 SR V-2 - Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 51.31 | 51.31 | 18.9 | False | None | None | False | None | False | 969.759 | 0 | 2983745 | 98970 | None | PWD 21-22 SR V-2 - Page No-47 It No-8.34.1 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. SECOND FLOOR | Sqm | 51.81 | 51.81 | 18.9 | False | None | None | False | None | False | 979.209 | 0 | 2983746 | 98970 | None | PWD 21-22 SR V-2 - Page No-83 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.GROUND FLOOR | Kg | 619.5 | 619.5 | 180.0 | False | None | None | False | None | False | 111510.0 | 0 | 2983747 | 98970 | None | PWD 21-22 SR V-2 - Page No-83 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.FIRST FLOOR | Kg | 625.7 | 625.7 | 180.0 | False | None | None | False | None | False | 112626.0 | 0 | 2983748 | 98970 | None | PWD 21-22 SR V-2 - Page No-83 It No-11.28 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.SECOND FLOOR | Kg | 631.89 | 631.89 | 180.0 | False | None | None | False | None | False | 113740.2 | 0 | 2983749 | 98970 | None | PWD 21-22 SR V-2 - Page No-41 It No-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 218.06 | 218.06 | 243.87 | False | None | None | False | None | False | 53178.2922 | 0 | 2983750 | 98970 | None | PWD 21-22 SR V-2 - Page No-41 It No-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 220.24 | 220.24 | 236.51 | False | None | None | False | None | False | 52088.9624 | 0 | 2983751 | 98970 | None | PWD 21-22 SR V-2 - Page No-41 It No-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 222.43 | 222.43 | 236.51 | False | None | None | False | None | False | 52606.9193 | 0 | 2983752 | 98970 | None | PWD 21-22 SR V-2 - Page No-41 It No-8.10 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required
smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 224.61 | 224.61 | 236.51 | False | None | None | False | None | False | 53122.5111 | 0 | 2983753 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 364.27 | 364.27 | 247.55 | False | None | None | False | None | False | 90175.0385 | 0 | 2983754 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 367.91 | 367.91 | 580.4 | False | None | None | False | None | False | 213534.964 | 0 | 2983755 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 371.55 | 371.55 | 580.4 | False | None | None | False | None | False | 215647.62 | 0 | 2983756 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.5.2 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 375.19 | 375.19 | 27.768 | False | None | None | False | None | False | 10418.27592 | 0 | 2983757 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 398.96 | 398.96 | 144.57 | False | None | None | False | None | False | 57677.6472 | 0 | 2983758 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 402.95 | 402.95 | 210.45 | False | None | None | False | None | False | 84800.8275 | 0 | 2983759 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 406.94 | 406.94 | 210.45 | False | None | None | False | None | False | 85640.523 | 0 | 2983760 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 410.93 | 410.93 | 217.02 | False | None | None | False | None | False | 89180.0286 | 0 | 2983761 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.2.1 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer-in-Charge.TERRACE FLOOR | Sqm | 56.15 | 56.15 | 140.55 | False | None | None | False | None | False | 7891.8825 | 0 | 2983762 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Rough Plastering For Dadooing works Toilet Area DadooingFIRST FLOOR | Sqm | 310.34 | 310.34 | 50.92 | False | None | None | False | None | False | 15802.5128 | 0 | 2983763 | 98970 | None | PWD 21-22 SR V-2 - Page No-42 It No-8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Rough Plastering For Dadooing works Toilet Area DadooingSECOND FLOOR | Sqm | 313.42 | 313.42 | 50.92 | False | None | None | False | None | False | 15959.3464 | 0 | 2983764 | 98970 | None | PWD 21-22 SR V-2 - Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. FIRST FLOOR | Sqm | 1297.69 | 1297.69 | 50.93 | False | None | None | False | None | False | 66091.3517 | 0 | 2983765 | 98970 | None | PWD 21-22 SR V-2 - Page No-65 It No-9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. SECOND FLOOR | Sqm | 1310.54 | 1310.54 | 50.92 | False | None | None | False | None | False | 66732.6968 | 0 | 2983766 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.12.12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmGROUND FLOOR | Sqm | 1346.79 | 1346.79 | 7.95 | False | None | None | False | None | False | 10706.9805 | 0 | 2983767 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.12.12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmFIRST FLOOR | Sqm | 1360.26 | 1360.26 | 131.19 | False | None | None | False | None | False | 178452.5094 | 0 | 2983768 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.12.12 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSECOND FLOOR | Sqm | 1373.73 | 1373.73 | 131.19 | False | None | None | False | None | False | 180219.6387 | 0 | 2983769 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.FIRST FLOOR | Sqm | 953.56 | 953.56 | 20.52 | False | None | None | False | None | False | 19567.0512 | 0 | 2983770 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.11 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. SECOND FLOOR | Sqm | 963.0 | 963.0 | 20.52 | False | None | None | False | None | False | 19760.76 | 0 | 2983771 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.12.5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mmGROUND FLOOR | Sqm | 2262.41 | 2262.41 | 31.66 | False | None | None | False | None | False | 71627.9006 | 0 | 2983772 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.12.5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mmFIRST FLOOR | Sqm | 2285.04 | 2285.04 | 34.15 | False | None | None | False | None | False | 78034.116 | 0 | 2983773 | 98970 | None | PWD 21-22 SR V-2 - Page No-60 It No-9.12.5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mmSECOND FLOOR | Sqm | 2307.66 | 2307.66 | 34.15 | False | None | None | False | None | False | 78806.589 | 0 | 2983774 | 98970 | None | PWD 21-22 SR V-2 - Page No-64 It No-9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.GROUND FLOOR | Sqm | 2967.41 | 2967.41 | 15.63 | False | None | None | False | None | False | 46380.6183 | 0 | 2983775 | 98970 | None | PWD 21-22 SR V-2 - Page No-64 It No-9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications.FIRST FLOOR | Sqm | 2997.08 | 2997.08 | 14.28 | False | None | None | False | None | False | 42798.3024 | 0 | 2983776 | 98970 | None | PWD 21-22 SR V-2 - Page No-64 It No-9.30 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed, including cost of materials, mortar, labour, curing complete as per specifications. SECOND FLOOR | Sqm | 3026.75 | 3026.75 | 15.63 | False | None | None | False | None | False | 47308.1025 | 0 | 2983777 | 98970 | None | PWD 21-22 SR V-2 - Page No-64 It No-9.32 | Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 281 kg per m2 over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications.GROUND FLOOR | Sqm | 1418.66 | 1418.66 | 10.75 | False | None | None | False | None | False | 15250.595 | 0 | 2983778 | 98970 | None | PWD 21-22 SR V-2 - Page No-75 It No-11.3 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals
20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, lockingarrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of
the Engineer-in-Charge. | Sqm | 8131.56 | 8131.56 | 9.2 | False | None | None | False | None | False | 74810.352 | 0 | 2983779 | 98970 | None | PWD 21-22 SR V-2 - Page No-75 It No-11.5.2 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges ofmachinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4273.31 | 4273.31 | 2.1 | False | None | None | False | None | False | 8973.951 | 0 | 2983780 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.GROUND FLOOR | Sqm | 102.84 | 102.84 | 491.418 | False | None | None | False | None | False | 50537.42712 | 0 | 2983781 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.FIRST FLOOR | Sqm | 103.87 | 103.87 | 816.91 | False | None | None | False | None | False | 84852.4417 | 0 | 2983782 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge.SECOND FLOOR | Sqm | 104.89 | 104.89 | 816.91 | False | None | None | False | None | False | 85685.6899 | 0 | 2983783 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.51 | Providing and applying white cement based putty o average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prerare the surface evevn and smooth complete as per specifications and as per directions of Engineer in incharge. TERRACE FLOOR | Sqm | 105.92 | 105.92 | 264.278 | False | None | None | False | None | False | 27992.32576 | 0 | 2983784 | 98970 | None | PWD 21-22 SR V-2 - Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 49.56 | 49.56 | 491.418 | False | None | None | False | None | False | 24354.67608 | 0 | 2983785 | 98970 | None | PWD 21-22 SR V-2 - Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.FIRST FLOOR | Sqm | 50.06 | 50.06 | 816.91 | False | None | None | False | None | False | 40894.5146 | 0 | 2983786 | 98970 | None | PWD 21-22 SR V-2 - Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.SECOND FLOOR | Sqm | 50.55 | 50.55 | 816.91 | False | None | None | False | None | False | 41294.8005 | 0 | 2983787 | 98970 | None | PWD 21-22 SR V-2 - Page No-51 It No-8.55.2 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.TERRACE FLOOR | Sqm | 51.05 | 51.05 | 264.278 | False | None | None | False | None | False | 13491.3919 | 0 | 2983788 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.GROUND FLOOR | Sqm | 97.88 | 97.88 | 491.418 | False | None | None | False | None | False | 48099.99384 | 0 | 2983789 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.FIRST FLOOR | Sqm | 98.86 | 98.86 | 816.91 | False | None | None | False | None | False | 80759.7226 | 0 | 2983790 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. SECOND FLOOR | Sqm | 99.84 | 99.84 | 816.91 | False | None | None | False | None | False | 81560.2944 | 0 | 2983791 | 98970 | None | PWD 21-22 SR V-2 - Page No-50 It No-8.54.2 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. TERRACE FLOOR | Sqm | 100.82 | 100.82 | 264.278 | False | None | None | False | None | False | 26644.50796 | 0 | 2983792 | 98970 | None | PWD 21-22 SR V-2 - Page No-46 It No-8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade
:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 168.5 | 168.5 | 144.57 | False | None | None | False | None | False | 24360.045 | 0 | 2983793 | 98970 | None | PWD 21-22 SR V-2 - Page No-46 It No-8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade
:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 170.19 | 170.19 | 210.45 | False | None | None | False | None | False | 35816.4855 | 0 | 2983794 | 98970 | None | PWD 21-22 SR V-2 - Page No-46 It No-8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade
:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 171.87 | 171.87 | 210.45 | False | None | None | False | None | False | 36170.0415 | 0 | 2983795 | 98970 | None | PWD 21-22 SR V-2 - Page No-46 It No-8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade
:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.TERRACE FLOOR | Sqm | 173.56 | 173.56 | 217.02 | False | None | None | False | None | False | 37665.9912 | 0 | 2983796 | 98970 | None | PWD 21-22 SR V-2 - Page No-131 It No-15.10 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.FIRST FLOOR Toilet | Sqm | 932.29 | 932.29 | 20.52 | False | None | None | False | None | False | 19130.5908 | 0 | 2983797 | 98970 | None | PWD 21-22 SR V-2 - Page No-131 It No-15.10 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.SECOND FLOOR Toilet | Sqm | 941.52 | 941.52 | 20.52 | False | None | None | False | None | False | 19319.9904 | 0 | 2983798 | 98970 | None | V-1, 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,
and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7342.31 | 7342.31 | 38.55 | False | None | None | False | None | False | 283046.0505 | 0 | 2983799 | 98970 | None | PWD 21-22 SR V- - Page No It No-8.80 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 63.19 | 63.19 | 600.65 | False | None | None | False | None | False | 37955.0735 | 0 | 2983800 | 98970 | None | SR 2018-19 | KSRB:15.8.2 Providing and fixing plaster mesh 150mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications and as directed by the engineer in charge.. (length of mesh only be measured for payment), Item No.15.35 of NEZ KLB SR 2018-19) | Sqm | 38.41 | 38.41 | 1875.9 | False | None | None | False | None | False | 72053.319 | 0 | 2983801 | 98970 | None | PWD 21-22 SR V-2 - Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.GROUND FLOOR | Sqm | 9.91 | 9.91 | 3.6 | False | None | None | False | None | False | 35.676 | 0 | 2983802 | 98970 | None | PWD 21-22 SR V-2 - Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.FIRST FLOOR | Sqm | 10.01 | 10.01 | 25.92 | False | None | None | False | None | False | 259.4592 | 0 | 2983803 | 98970 | None | PWD 21-22 SR V-2 - Page No-44 It No-8.16.4 | Providing 12 mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand): Moulded Band including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.SECOND FLOOR | Sqm | 10.11 | 10.11 | 25.92 | False | None | None | False | None | False | 262.0512 | 0 | 2983804 | 98970 | None | SR 2018-19 It No-39.3 | Manufacturing, supplying and fixing wooden ward robe of 0.60m deep using 19mm thick vinyl bonded water proof block board, shutters allround ward robe, lockable drawers with sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable shutters with 19mm x 6mm thick plain teak wood beading, lipping 1.5mm thick commercial ply vertical support finished in approved 1mm lamination sheet of approved colour, shade and quality on all exposed surfaces. Inner surface painted with 2 coats of white synthetic enamel paint over 2 coats of Patti, one coat of wood primer, including cost of brass fittings, parliamentary hinges, C handles, tower bolts, magnetic catches, approved brand lock, adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour charges, complete as per specificationFIRST FLOOR | Sqm | 13454.95 | 13454.95 | 30.87 | False | None | None | False | None | False | 415354.3065 | 0 | 2983805 | 98970 | None | SR 2018-19 It No-39.3 | Manufacturing, supplying and fixing wooden ward robe of 0.60m deep using 19mm thick vinyl bonded water proof block board, shutters allround ward robe, lockable drawers with sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable shutters with 19mm x 6mm thick plain teak wood beading, lipping 1.5mm thick commercial ply vertical support finished in approved 1mm lamination sheet of approved colour, shade and quality on all exposed surfaces. Inner surface painted with 2 coats of white synthetic enamel paint over 2 coats of Patti, one coat of wood primer, including cost of brass fittings, parliamentary hinges, C handles, tower bolts, magnetic catches, approved brand lock, adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour charges, complete as per specificationSECOND FLOOR | Sqm | 13588.16 | 13588.16 | 30.87 | False | None | None | False | None | False | 419466.4992 | 0 | 2983806 | 98970 | None | SR 2021-22, V-1, pg. 17, I.No 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)
M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates
Terrace floor head room & column | CUBIC METER | 7894.39 | 7894.39 | 8.21 | False | None | None | False | None | False | 64812.9419 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Girls Hostel-Plumbing & Sanitation System | 915127.47 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983807 | 98971 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet FIRST FLOOR | Each | 6263.21 | 6263.21 | 3.0 | False | None | None | False | None | False | 18789.63 | 0 | 2983808 | 98971 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :
W.C. pan with ISI marked white solid plastic seat and lid Pedestal Type Water Closet SECOND FLOOR | Each | 6325.22 | 6325.22 | 3.0 | False | None | None | False | None | False | 18975.66 | 0 | 2983809 | 98971 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern WashBasin FIRST FLOOR | Each | 2698.0 | 2698.0 | 1.0 | False | None | None | False | None | False | 2698.0 | 0 | 2983810 | 98971 | None | PWD Volume-2 SR2021-22 Page No121 Item No14.7.2 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Standard Pattern WashBasin SECOND FLOOR | Each | 2724.71 | 2724.71 | 1.0 | False | None | None | False | None | False | 2724.71 | 0 | 2983811 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm mirror FIRST FLOOR | Each | 1087.46 | 1087.46 | 2.0 | False | None | None | False | None | False | 2174.92 | 0 | 2983812 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm mirror SECOND FLOOR | Each | 1098.22 | 1098.22 | 2.0 | False | None | None | False | None | False | 2196.44 | 0 | 2983813 | 98971 | None | PWD Volume-2 SR2021-22 Page No128 Item No14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail FIRST FLOOR | Each | 475.53 | 475.53 | 5.0 | False | None | None | False | None | False | 2377.65 | 0 | 2983814 | 98971 | None | PWD Volume-2 SR2021-22 Page No128 Item No14.40.2 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. Towel Rail SECOND FLOOR | Each | 480.24 | 480.24 | 5.0 | False | None | None | False | None | False | 2401.2 | 0 | 2983815 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 , 14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines Waste Pipe 40mm dia pipes, From wash basin waste lines Waste Pipe GROUND FLOOR | m | 270.1 | 270.1 | 5.0 | False | None | None | False | None | False | 1350.5 | 0 | 2983816 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines Waste Pipe 40mm dia pipes, From wash basin waste lines Waste Pipe FIRST FLOOR | m | 272.8 | 272.8 | 3.0 | False | None | None | False | None | False | 818.4 | 0 | 2983817 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.28.2.2 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.40mm dia pipes, From wash basin waste lines Waste Pipe 40mm dia pipes, From wash basin waste lines Waste Pipe SECOND FLOOR | m | 275.5 | 275.5 | 3.0 | False | None | None | False | None | False | 826.5 | 0 | 2983818 | 98971 | None | PWD Volume-5 SR2021-22 Page No187 Item NoT090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines GROUND FLOOR | m | 172.22 | 172.22 | 3.0 | False | None | None | False | None | False | 516.66 | 0 | 2983819 | 98971 | None | PWD Volume-5 SR2021-22 Page No187 Item NoT090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines FIRST FLOOR | m | 173.94 | 173.94 | 3.0 | False | None | None | False | None | False | 521.82 | 0 | 2983820 | 98971 | None | PWD Volume-5 SR2021-22 Page No187 Item NoT090D | Providing and fixing normal gauge polythene pipes of approved quality with special flange compression type fittings of approved make including trench excavation and refilling etc. for EXTERNAL WORKS with: 50mm nominal bore pipes, From Sink & Urinal lines SECOND FLOOR | m | 175.67 | 175.67 | 3.0 | False | None | None | False | None | False | 527.01 | 0 | 2983821 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Internal wall GROUND FLOOR | m | 152.4 | 152.4 | 9.0 | False | None | None | False | None | False | 1371.6 | 0 | 2983822 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Internal wall FIRST FLOOR | m | 153.92 | 153.92 | 20.0 | False | None | None | False | None | False | 3078.4 | 0 | 2983823 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines Internal wall SECOND FLOOR | m | 155.44 | 155.44 | 20.0 | False | None | None | False | None | False | 3108.8 | 0 | 2983824 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines External wall GROUND FLOOR | m | 152.4 | 152.4 | 5.0 | False | None | None | False | None | False | 762.0 | 0 | 2983825 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines External wall FIRST FLOOR | m | 153.92 | 153.92 | 6.0 | False | None | None | False | None | False | 923.52 | 0 | 2983826 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3711 | PVC pipe - OD 75mm and 6 Kg/sqcm, waste lines External wall SECOND FLOOR | m | 155.44 | 155.44 | 6.0 | False | None | None | False | None | False | 932.64 | 0 | 2983827 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Internal wall GROUND FLOOR | m | 315.95 | 315.95 | 3.0 | False | None | None | False | None | False | 947.85 | 0 | 2983828 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Internal wall FIRST FLOOR | m | 319.1 | 319.1 | 16.0 | False | None | None | False | None | False | 5105.6 | 0 | 2983829 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines Internal wallSECOND FLOOR | m | 322.26 | 322.26 | 16.0 | False | None | None | False | None | False | 5156.16 | 0 | 2983830 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines External wall GROUND FLOOR | m | 315.95 | 315.95 | 7.0 | False | None | None | False | None | False | 2211.65 | 0 | 2983831 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines External wall FIRST FLOOR | m | 319.1 | 319.1 | 18.0 | False | None | None | False | None | False | 5743.8 | 0 | 2983832 | 98971 | None | PWD Volume-5 SR2021-22 Page No34 Item No3713 | PVC pipe - OD 110mm and 6 Kg/sqcm, sanitary lines External wall SECOND FLOOR | m | 322.26 | 322.26 | 18.0 | False | None | None | False | None | False | 5800.68 | 0 | 2983833 | 98971 | None | 1st Addenda S.N-27 item No-13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter GROUND FLOOR | m | 313.47 | 313.47 | 12.0 | False | None | None | False | None | False | 3761.64 | 0 | 2983834 | 98971 | None | PWD Volume-5 SR2021-22 Page No27 Item No13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter FIRST FLOOR | m | 316.6 | 316.6 | 12.0 | False | None | None | False | None | False | 3799.2 | 0 | 2983835 | 98971 | None | PWD Volume-5 SR2021-22 Page No27 Item No13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10mm gap for thermal expansion,(i)the single socketed pipes 100mm diameter SECOND FLOOR | m | 319.74 | 319.74 | 12.0 | False | None | None | False | None | False | 3836.88 | 0 | 2983836 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Beveled Edge mirror FIRST FLOOR | Nos. | 1215.1 | 1215.1 | 1.0 | False | None | None | False | None | False | 1215.1 | 0 | 2983837 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No14.31 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Beveled Edge mirror SECOND FLOOR | Nos. | 1227.13 | 1227.13 | 1.0 | False | None | None | False | None | False | 1227.13 | 0 | 2983838 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Shower Rose FIRST FLOOR | Nos. | 275.31 | 275.31 | 3.0 | False | None | None | False | None | False | 825.93 | 0 | 2983839 | 98971 | None | PWD Volume-2 SR2021-22 Page No126 Item No13.9.2 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter Shower Rose SECOND FLOOR | Nos. | 278.03 | 278.03 | 3.0 | False | None | None | False | None | False | 834.09 | 0 | 2983840 | 98971 | None | PWD Volume-2 SR2021-22 Page No125 Item No14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. Wall Mixer FIRST FLOOR | Nos. | 7191.74 | 7191.74 | 3.0 | False | None | None | False | None | False | 21575.22 | 0 | 2983841 | 98971 | None | PWD Volume-2 SR2021-22 Page No125 Item No14.22B | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. Wall Mixer SECOND FLOOR | Nos. | 7262.94 | 7262.94 | 3.0 | False | None | None | False | None | False | 21788.82 | 0 | 2983842 | 98971 | None | PWD Volume-5 SR2021-22 Page No112 Item NoH160A | Supplying and fixing DI/CI puddle flanges confoMing to IS 7181-1986 with latest ammendments., in position for RCC walls including hoisting and conveying them to work spot with all lead and lifts etc. complete a)For DI/CI puddle flanges of 80mm dia.Puddle Flanges TERRACE FLOOR(OHT) | No. | 1890.71 | 1890.71 | 2.0 | False | None | None | False | None | False | 3781.42 | 0 | 2983843 | 98971 | None | 1st Addenda S.N-10 item No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes Cold Water Supply GROUND FLOOR | m | 379.13 | 379.13 | 6.0 | False | None | None | False | None | False | 2274.78 | 0 | 2983844 | 98971 | None | 1st Addenda S.N-10 item No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes Cold Water Supply FIRST FLOOR | m | 382.93 | 382.93 | 8.0 | False | None | None | False | None | False | 3063.44 | 0 | 2983845 | 98971 | None | 1st Addenda S.N-10 item No-13.32.1 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes Cold Water Supply SECOND FLOOR | m | 386.72 | 386.72 | 8.0 | False | None | None | False | None | False | 3093.76 | 0 | 2983846 | 98971 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes Cold Water Supply GROUND FLOOR | m | 462.15 | 462.15 | 12.0 | False | None | None | False | None | False | 5545.8 | 0 | 2983847 | 98971 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes Cold Water Supply FIRST FLOOR | m | 466.77 | 466.77 | 16.0 | False | None | None | False | None | False | 7468.32 | 0 | 2983848 | 98971 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia pipes Cold Water Supply SECOND FLOOR | m | 471.39 | 471.39 | 16.0 | False | None | None | False | None | False | 7542.24 | 0 | 2983849 | 98971 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.Hot Water Supply GROUND FLOOR | m | 462.15 | 462.15 | 2.0 | False | None | None | False | None | False | 924.3 | 0 | 2983850 | 98971 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.Hot Water Supply FIRST FLOOR | m | 466.77 | 466.77 | 4.0 | False | None | None | False | None | False | 1867.08 | 0 | 2983851 | 98971 | None | 1st Addenda S.N-10 item No-13.32.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.Hot Water Supply SECOND FLOOR | m | 471.39 | 471.39 | 4.0 | False | None | None | False | None | False | 1885.56 | 0 | 2983852 | 98971 | None | 1st Addenda S.N-10 item No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Hot Water Supply GROUND FLOOR | m | 589.76 | 589.76 | 3.0 | False | None | None | False | None | False | 1769.28 | 0 | 2983853 | 98971 | None | 1st Addenda S.N-10 item No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Hot Water Supply FIRST FLOOR | m | 595.66 | 595.66 | 5.0 | False | None | None | False | None | False | 2978.3 | 0 | 2983854 | 98971 | None | 1st Addenda S.N-10 item No-13.32.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal dia pipes Hot Water Supply SECOND FLOOR | m | 601.56 | 601.56 | 5.0 | False | None | None | False | None | False | 3007.8 | 0 | 2983855 | 98971 | None | 1st Addenda S.N-10 item No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water SupplyGROUND FLOOR | m | 688.88 | 688.88 | 2.0 | False | None | None | False | None | False | 1377.76 | 0 | 2983856 | 98971 | None | 1st Addenda S.N-10 item No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply FIRST FLOOR | m | 695.77 | 695.77 | 4.0 | False | None | None | False | None | False | 2783.08 | 0 | 2983857 | 98971 | None | 1st Addenda S.N-10 item No-13.32.4 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply SECOND FLOOR | m | 702.66 | 702.66 | 4.0 | False | None | None | False | None | False | 2810.64 | 0 | 2983858 | 98971 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes From sump to Bldg | m | 581.09 | 581.09 | 100.0 | False | None | None | False | None | False | 58109.0 | 0 | 2983859 | 98971 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply -Down take GROUND FLOOR | m | 581.09 | 581.09 | 12.0 | False | None | None | False | None | False | 6973.08 | 0 | 2983860 | 98971 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply -Down take FIRST FLOOR | m | 586.9 | 586.9 | 8.0 | False | None | None | False | None | False | 4695.2 | 0 | 2983861 | 98971 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply -Down take SECOND FLOOR | m | 592.71 | 592.71 | 8.0 | False | None | None | False | None | False | 4741.68 | 0 | 2983862 | 98971 | None | 1st Addenda S.N-11 item No-13.33.5 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32 mm nominal dia pipes Cold Water Supply - Ring MainTERRACE FLOOR | m | 598.52 | 598.52 | 30.0 | False | None | None | False | None | False | 17955.6 | 0 | 2983863 | 98971 | None | 1st Addenda S.N-11 item No-13.33.6 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot &cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 50 mm nominal dia Pipes Cold water Supply-From Tank TERRACE FLOOR | m | 895.87 | 895.87 | 13.0 | False | None | None | False | None | False | 11646.31 | 0 | 2983864 | 98971 | None | 1st Addenda S.N-12item No-13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. TERRACE FLOOR | Ltr | 9.93 | 9.93 | 3000.0 | False | None | None | False | None | False | 29790.0 | 0 | 2983865 | 98971 | None | PWD Volume-2 SR2021-22 Page No113 Item No13.5.3 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore TERRACE FLOOR | Nos. | 475.78 | 475.78 | 2.0 | False | None | None | False | None | False | 951.56 | 0 | 2983866 | 98971 | None | PWD Volume-5 SR2021-22 Page NoN180E Item No16.5 | For 40 mm dia GM (Copper alloy) Gate valves Cold water supply TERRACE FLOOR | Nos. | 1914.26 | 1914.26 | 4.0 | False | None | None | False | None | False | 7657.04 | 0 | 2983867 | 98971 | None | PWD Volume-5 SR2021-22 Page NoN180F Item No16.5 | For 50 mm dia GM (Copper alloy) Gate valves TERRACE FLOOR | Nos. | 2154.17 | 2154.17 | 2.0 | False | None | None | False | None | False | 4308.34 | 0 | 2983868 | 98971 | None | 1st Addenda S.N-16item No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. FIRST FLOOR | Each | 304.09 | 304.09 | 10.0 | False | None | None | False | None | False | 3040.9 | 0 | 2983869 | 98971 | None | 1st Addenda S.N-16item No-13.37 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. SECOND FLOOR | Each | 307.1 | 307.1 | 10.0 | False | None | None | False | None | False | 3071.0 | 0 | 2983870 | 98971 | None | PWD SR2018-19 Page No Item No11.37 | KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at bottom,0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOOR | Nos | 22121.11 | 22121.11 | 3.0 | False | None | None | False | None | False | 66363.33 | 0 | 2983871 | 98971 | None | PWD SR2018-19 Page No Item No11.38 | KSRB 12-5.2 : Constructing brick masonry circular type manhole 1.67 m internal dia at bottom, 0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50 class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using 40mm and downsize granite metal and making necessary channel in cement concrete M 50 with 20mm and downsize granite metal finished with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing centering, shuttering including cost of materials, labour charges, HOM of mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4 GROUND FLOOR | Nos | 36248.18 | 36248.18 | 3.0 | False | None | None | False | None | False | 108744.54 | 0 | 2983872 | 98971 | None | PWD SR2018-19 Page No Item No11.44 | KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 12.4.6 TERRACE FLOOR FLOOR(OHT) | Nos | 375.42 | 375.42 | 15.0 | False | None | None | False | None | False | 5631.3 | 0 | 2983873 | 98971 | None | PWD SR2018-19 Page No Item No11.50.2 | Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600mm | Nos. | 12625.41 | 12625.41 | 4.0 | False | None | None | False | None | False | 50501.64 | 0 | 2983874 | 98971 | None | PWD SR2021-22 Page No Item No11.50.3 | Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBS 450x450mm and 450mm depth ( clear inside dimension ) for single pipeline, using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 450x450mm | Nos | 7748.71 | 7748.71 | 4.0 | False | None | None | False | None | False | 30994.84 | 0 | 2983875 | 98971 | None | PWD Volume-1 SR2021-22 Page No 10 Item No117.1 | Earth work excavation for pipeline/cables trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m GROUND FLOOR | Cum | 582.33 | 582.33 | 162.0 | False | None | None | False | None | False | 94337.46 | 0 | 2983876 | 98971 | None | PWD Volume-2 SR2021-22 Page No 129 Item No14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder FIRST FLOOR | Each | 600.67 | 600.67 | 3.0 | False | None | None | False | None | False | 1802.01 | 0 | 2983877 | 98971 | None | PWD Volume-2 SR2021-22 Page No 129 Item No14.34.1 | Providing and fixing toilet paper holder : C.P. brass Toilet Paper Holder SECOND FLOOR | Each | 606.61 | 606.61 | 3.0 | False | None | None | False | None | False | 1819.83 | 0 | 2983878 | 98971 | None | 2018-19, 12.113.2 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cms FIRST FLOOR | Nos. | 336.3 | 336.3 | 8.0 | False | None | None | False | None | False | 2690.4 | 0 | 2983879 | 98971 | None | 2018-19 SR, 12.113.2 | Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cms SECOND FLOOR | Nos. | 336.3 | 336.3 | 8.0 | False | None | None | False | None | False | 2690.4 | 0 | 2983880 | 98971 | None | PWD Volume-5 SR2021-22 Page No 134Item NoM020D | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 160mm dia. GROUND FLOOR | m | 688.88 | 688.88 | 42.0 | False | None | None | False | None | False | 28932.96 | 0 | 2983881 | 98971 | None | PWD Volume-5 SR2021-22 Page No 134Item NoM020E | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Sanitary Work ). Pipes of SN4, 200mm dia. GROUND FLOOR | m | 688.88 | 688.88 | 80.0 | False | None | None | False | None | False | 55110.4 | 0 | 2983882 | 98971 | None | PWD Volume-5 SR2021-22 Page No 134Item NoM020D | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:( For external Rain water Work ).Pipes of SN4, 160mm dia. GROUND FLOOR | m | 688.88 | 688.88 | 20.0 | False | None | None | False | None | False | 13777.6 | 0 | 2983883 | 98971 | None | 1st Addenda S.N-18 item No-13.39 | Providing and fixing squre-mouth S.W gully trap class SP-1 complete with C.I grating brick masonry chamber 150 X100mm size Ptype with Non modular common burnt clay bricks of designation 3.5 & with water tight CI.cover with frame of 300x300mm size(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design. GROUND FLOOR | Nos. | 2848.46 | 2848.46 | 8.0 | False | None | None | False | None | False | 22787.68 | 0 | 2983884 | 98971 | None | Electrical SR Page No 27 Item No 7.2.1 | Supplying ...litres capacity vertical/horizontal type wall
mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided withheavy gauge brackets for wall mounting. 25 L ALL FLOOR | No. | 12154.0 | 12154.0 | 6.0 | False | None | None | False | None | False | 72924.0 | 0 |
| 1710137476000 | 0 | None | None | Buildings | Girls Hostel-Internal Electrification | 1854693.58 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2983885 | 98972 | None | ELE SR NO 2021-22 Item No 1.1.1 | Open Conduit System.Supply Heavy gauge PVC conduit pipe --- dia -- mm thich confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC eall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF Screws.19/20mm dia 2mm thick | m | 80.24 | 80.24 | 50.0 | False | None | None | False | None | False | 4012.0 | 0 | 2983886 | 98972 | None | ELE SR NO 2021-22 Item No 1.1.2 | Open Conduit System.Supply Heavy gauge PVC conduit pipe --- dia -- mm thich confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC eall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF Screws.25 mm dia 2mm thick | m | 94.4 | 94.4 | 100.0 | False | None | None | False | None | False | 9440.0 | 0 | 2983887 | 98972 | None | ELE SR NO 2021-22 Item No 1.2.1 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and usused ways of junction boxes and pipe ends should be covered using PVC end closures, run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thick | m | 71.98 | 71.98 | 558.0 | False | None | None | False | None | False | 40164.84 | 0 | 2983888 | 98972 | None | ELE SR NO 2021-22 Item No 1.2.2 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and usused ways of junction boxes and pipe ends should be covered using PVC end closures, run with 18SWG GI fish wire wherever necessary.25 mm dia 2mm thick | m | 82.6 | 82.6 | 390.0 | False | None | None | False | None | False | 32214.0 | 0 | 2983889 | 98972 | None | ELE SR NO 2021-22 Item No 1.2.3 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and usused ways of junction boxes and pipe ends should be covered using PVC end closures, run with 18SWG GI fish wire wherever necessary.32mm dia 2.5mm thick | m | 109.74 | 109.74 | 30.0 | False | None | None | False | None | False | 3292.2 | 0 | 2983890 | 98972 | None | ELE SR NO 2021-22 Item No 1.3.1 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 19/20mm dia 2mm thick | m | 88.5 | 88.5 | 175.0 | False | None | None | False | None | False | 15487.5 | 0 | 2983891 | 98972 | None | ELE SR NO 2021-22 Item No 1.3.2 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 25 mm dia 2mm thick | m | 94.4 | 94.4 | 300.0 | False | None | None | False | None | False | 28320.0 | 0 | 2983892 | 98972 | None | ELE SR NO 2021-22 Item No 1.3.3 | Supplying heavy gauge PVC conduit pipe --- mm dia -- thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes, adhesive paste etc., by grove cutting in the wall surface and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18SWG FI fish wire run througout the conduit whereever neceessar. 32mm dia 2.5mm thick | m | 123.9 | 123.9 | 40.0 | False | None | None | False | None | False | 4956.0 | 0 | 2983893 | 98972 | None | ELE SR NO 2021-22 Item No 1.4.5 | Supplying and fixing sheet Metal box made out of 18SWG sheet metal with necessary holes for cable/lconduit entry as required with one coat of primer of approved make etc.200x200x65 mm | Each | 395.3 | 395.3 | 4.0 | False | None | None | False | None | False | 1581.2 | 0 | 2983894 | 98972 | None | ELE SR NO 2021-22 Item No 1.5.1 | Supplying and fixing PVC/Metal conduit Deep Junction box19/20mm deep Junction box | Each | 57.82 | 57.82 | 90.0 | False | None | None | False | None | False | 5203.8 | 0 | 2983895 | 98972 | None | ELE SR NO 2021-22 Item No 1.5.2 | Supplying and fixing PVC/Metal conduit Deep Junction box25mm deep Junction box | Each | 60.18 | 60.18 | 4.0 | False | None | None | False | None | False | 240.72 | 0 | 2983896 | 98972 | None | ELE SR NO 2021-22 Item No 1.5.3 | Supplying and fixing PVC/Metal conduit Deep Junction box32mm deep Junction box | Each | 81.42 | 81.42 | 2.0 | False | None | None | False | None | False | 162.84 | 0 | 2983897 | 98972 | None | ELE SR NO 2021-22 Item No 1.7.1 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit in brick wall | m | 30.68 | 30.68 | 10.0 | False | None | None | False | None | False | 306.8 | 0 | 2983898 | 98972 | None | ELE SR NO 2021-22 Item No 1.7.2 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floor | m | 73.16 | 73.16 | 10.0 | False | None | None | False | None | False | 731.6 | 0 | 2983899 | 98972 | None | ELE SR NO 2021-22 Item No 1.8.1 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required.20mm | m | 31.86 | 31.86 | 10.0 | False | None | None | False | None | False | 318.6 | 0 | 2983900 | 98972 | None | ELE SR NO 2021-22 Item No 1.8.2 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required.25mm | m | 33.04 | 33.04 | 10.0 | False | None | None | False | None | False | 330.4 | 0 | 2983901 | 98972 | None | ELE SR NO 2021-22 Item No 1.8.3 | Supplying and fixing PVC casing and capping on the wall or ceiling using necessary materials like bends,junctionx box,elbows,screws at an interval of 300mm etc as required.32mm | m | 48.38 | 48.38 | 10.0 | False | None | None | False | None | False | 483.8 | 0 | 2983902 | 98972 | None | ELE SR NO 2021-22 Item No 1.9.1 | Supplying PVC/GI Flexible conduit pipe -- mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y.20mm | m | 29.5 | 29.5 | 10.0 | False | None | None | False | None | False | 295.0 | 0 | 2983903 | 98972 | None | ELE SR NO 2021-22 Item No 1.9.2 | Supplying PVC/GI Flexible conduit pipe -- mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y.25mm | m | 36.58 | 36.58 | 10.0 | False | None | None | False | None | False | 365.8 | 0 | 2983904 | 98972 | None | ELE SR NO 2021-22 Item No 1.9.3 | Supplying PVC/GI Flexible conduit pipe -- mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on on either end of the pipe terminated complet;y.32mm | m | 48.38 | 48.38 | 10.0 | False | None | None | False | None | False | 483.8 | 0 | 2983905 | 98972 | None | ELE SR NO 2021-22 Item No 1.1.2 | Supplying and fixing of Metal Fan box with Round Hook. | No. | 192.34 | 192.34 | 28.0 | False | None | None | False | None | False | 5385.52 | 0 | 2983906 | 98972 | None | ELE SR NO 2021-22 Item No 2.2.1 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point up to 3Mtr from tapping point to out let via switch | Point | 296.18 | 296.18 | 26.0 | False | None | None | False | None | False | 7700.68 | 0 | 2983907 | 98972 | None | ELE SR NO 2021-22 Item No 2.2.2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 425.98 | 425.98 | 25.0 | False | None | None | False | None | False | 10649.5 | 0 | 2983908 | 98972 | None | ELE SR NO 2021-22 Item No 2.2.3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 639.56 | 639.56 | 72.0 | False | None | None | False | None | False | 46048.32 | 0 | 2983909 | 98972 | None | ELE SR NO 2021-22 Item No 2.2.4 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switches | Point | 791.78 | 791.78 | 39.0 | False | None | None | False | None | False | 30879.42 | 0 | 2983910 | 98972 | None | ELE SR NO 2021-22 Item No 2.2.5 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to
IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switches | Point | 791.78 | 791.78 | 1.0 | False | None | None | False | None | False | 791.78 | 0 | 2983911 | 98972 | None | ELE SR NO 2021-22 Item No 2.3.1 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.1 Sq.mm | m | 21.24 | 21.24 | 50.0 | False | None | None | False | None | False | 1062.0 | 0 | 2983912 | 98972 | None | ELE SR NO 2021-22 Item No 2.3.2 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.1.5 Sq.mm | m | 30.68 | 30.68 | 750.0 | False | None | None | False | None | False | 23010.0 | 0 | 2983913 | 98972 | None | ELE SR NO 2021-22 Item No 2.3.3 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.2.5 Sq.mm | m | 47.2 | 47.2 | 1410.0 | False | None | None | False | None | False | 66552.0 | 0 | 2983914 | 98972 | None | ELE SR NO 2021-22 Item No 2.3.4 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.4 Sq.mm | m | 69.62 | 69.62 | 220.0 | False | None | None | False | None | False | 15316.4 | 0 | 2983915 | 98972 | None | ELE SR NO 2021-22 Item No 2.3.5 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.6 Sq.mm | m | 102.66 | 102.66 | 40.0 | False | None | None | False | None | False | 4106.4 | 0 | 2983916 | 98972 | None | ELE SR NO 2021-22 Item No 2.3.4 | Wiring for Lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concaled system of wiring with speicified IS-694 conforming to latest amendments.10 Sq.mm | m | 185.26 | 185.26 | 120.0 | False | None | None | False | None | False | 22231.2 | 0 | 2983917 | 98972 | None | ELE SR NO 2021-22 Item No 2.5.8 | Supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor conforming to IS 8130-1984 and (Virgin) PVC Insulation sheathed suitable for working voltage upto 1100V as per IS 694:2010.3C x 2.5 mm2 | m | 375.24 | 375.24 | 50.0 | False | None | None | False | None | False | 18762.0 | 0 | 2983918 | 98972 | None | ELE SR NO 2021-22 Item No 3.4.1 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 145.14 | 145.14 | 26.0 | False | None | None | False | None | False | 3773.64 | 0 | 2983919 | 98972 | None | ELE SR NO 2021-22 Item No 3.4.2 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way | Each | 162.84 | 162.84 | 5.0 | False | None | None | False | None | False | 814.2 | 0 | 2983920 | 98972 | None | ELE SR NO 2021-22 Item No 3.4.3 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6Way | Each | 250.16 | 250.16 | 21.0 | False | None | None | False | None | False | 5253.36 | 0 | 2983921 | 98972 | None | ELE SR NO 2021-22 Item No 3.4.4 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way | Each | 295.0 | 295.0 | 5.0 | False | None | None | False | None | False | 1475.0 | 0 | 2983922 | 98972 | None | ELE SR NO 2021-22 Item No 3.4.5 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12Way | Each | 383.5 | 383.5 | 8.0 | False | None | None | False | None | False | 3068.0 | 0 | 2983923 | 98972 | None | ELE SR NO 2021-22 Item No 3.4.6 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16-18Way | Each | 417.72 | 417.72 | 12.0 | False | None | None | False | None | False | 5012.64 | 0 | 2983924 | 98972 | None | ELE SR NO 2021-22 Item No 3.5.1 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 3 Module | Each | 179.36 | 179.36 | 26.0 | False | None | None | False | None | False | 4663.36 | 0 | 2983925 | 98972 | None | ELE SR NO 2021-22 Item No 3.5.2 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 Module | Each | 206.5 | 206.5 | 5.0 | False | None | None | False | None | False | 1032.5 | 0 | 2983926 | 98972 | None | ELE SR NO 2021-22 Item No 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 Module | Each | 287.92 | 287.92 | 21.0 | False | None | None | False | None | False | 6046.32 | 0 | 2983927 | 98972 | None | ELE SR NO 2021-22 Item No 3.5.4 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 Module | Each | 356.36 | 356.36 | 5.0 | False | None | None | False | None | False | 1781.8 | 0 | 2983928 | 98972 | None | ELE SR NO 2021-22 Item No 3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 Module | Each | 428.34 | 428.34 | 8.0 | False | None | None | False | None | False | 3426.72 | 0 | 2983929 | 98972 | None | ELE SR NO 2021-22 Item No 3.5.6 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 16-18 Module | Each | 475.54 | 475.54 | 12.0 | False | None | None | False | None | False | 5706.48 | 0 | 2983930 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps one way Switch | Each | 103.84 | 103.84 | 220.0 | False | None | None | False | None | False | 22844.8 | 0 | 2983931 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps Two way Switch | Each | 179.36 | 179.36 | 8.0 | False | None | None | False | None | False | 1434.88 | 0 | 2983932 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6Amps 3way socket | Each | 191.16 | 191.16 | 65.0 | False | None | None | False | None | False | 12425.4 | 0 | 2983933 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Stepped Fan Regulator. | Each | 369.34 | 369.34 | 28.0 | False | None | None | False | None | False | 10341.52 | 0 | 2983934 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.8 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.16Amps one way switch | Each | 293.82 | 293.82 | 10.0 | False | None | None | False | None | False | 2938.2 | 0 | 2983935 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Bell Push | Each | 187.62 | 187.62 | 14.0 | False | None | None | False | None | False | 2626.68 | 0 | 2983936 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.11 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16Amps universal socket | Each | 293.82 | 293.82 | 10.0 | False | None | None | False | None | False | 2938.2 | 0 | 2983937 | 98972 | None | ELE SR NO 2021-22 Item No 3.6.12 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.TV | Each | 173.46 | 173.46 | 1.0 | False | None | None | False | None | False | 173.46 | 0 | 2983938 | 98972 | None | EL SR No 2021-22 Item No 12.21 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote Ding Dong Bell | Each | 282.02 | 282.02 | 14.0 | False | None | None | False | None | False | 3948.28 | 0 | 2983939 | 98972 | None | EL SR No 2021-22 Item No 3.8 | Supplying 4mm thick plastic sheet with necessary nitches
for fixing switches, regulators etc, and fixing on existing
wooden or metal box using N.F. screws. | Sq CM | 0.32 | 0.32 | 3500.0 | False | None | None | False | None | False | 1120.0 | 0 | 2983940 | 98972 | None | ELE SR NO 2021-22 Item No 3.9 | Supplying and fixing hylum plastic sheet 3mm thick with
necessary nitches for fixing switches, regulators etc., and
fixing on existing wood or metal box using N. F. screws. | Sq CM | 0.28 | 0.28 | 3500.0 | False | None | None | False | None | False | 980.0 | 0 | 2983941 | 98972 | None | ELE SR NO 2021-22 Item No 3.11 | Supplying 50mm wooden plug, tapered from 50x50mm to 25x25mm and fixing by using binding wire before concreting a roof slab. | Each | 9.44 | 9.44 | 450.0 | False | None | None | False | None | False | 4248.0 | 0 | 2983942 | 98972 | None | ELE SR NO 2021-22 Item No 3.14.5 | Supplying and fixing/replacing of 6/16/32Amps electrical
accessories on existing switch board.6Amps Bakelite ceiling rose(KPWD ELE SR 2022-23,P.NO 6,3.14.5) | No | 74.34 | 74.34 | 30.0 | False | None | None | False | None | False | 2230.2 | 0 | 2983943 | 98972 | None | ELE SR NO 2021-22 Item No 3.14.6 | Supplying and fixing/replacing of 6/16/32Amps electrical
accessories on existing switch board.6 Amps lamp holder.(KPWD ELE SR 2022-23,P.NO 6,3.14.6) | No | 74.34 | 74.34 | 70.0 | False | None | None | False | None | False | 5203.8 | 0 | 2983944 | 98972 | None | ELE SR NO 2021-22 Item No 5.14.8 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Micro processor release and Earth Fault as per IS-13947. ( Icu = Ics) 125 A 25 kA. | No | 11884.96 | 11884.96 | 1.0 | False | None | None | False | None | False | 11884.96 | 0 | 2983945 | 98972 | None | ELE SR NO 2021-22 Item No 5.15 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | No | 1784.16 | 1784.16 | 1.0 | False | None | None | False | None | False | 1784.16 | 0 | 2983946 | 98972 | None | ELE SR NO 2021-22 Item No 5.17.1 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps SP. | No | 617.14 | 617.14 | 46.0 | False | None | None | False | None | False | 28388.44 | 0 | 2983947 | 98972 | None | ELE SR NO 2021-22 Item No 5.17.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6-32 Amps DP. | No | 1301.54 | 1301.54 | 3.0 | False | None | None | False | None | False | 3904.62 | 0 | 2983948 | 98972 | None | ELE SR NO 2021-22 Item No 5.17.9 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50-63 Amps TPN. | No | 2830.82 | 2830.82 | 5.0 | False | None | None | False | None | False | 14154.1 | 0 | 2983949 | 98972 | None | ELE SR NO 2021-22 Item No 5.18.9 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door12 Way SP & N | No | 2439.06 | 2439.06 | 1.0 | False | None | None | False | None | False | 2439.06 | 0 | 2983950 | 98972 | None | ELE SR NO 2021-22 Item No 5.18.12 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.II - Double Door 6 Way TP & N | No | 4407.3 | 4407.3 | 2.0 | False | None | None | False | None | False | 8814.6 | 0 | 2983951 | 98972 | None | ELE SR NO 2021-22 Item No 5.19.1 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 16A-25A 2 pole. | No | 5366.64 | 5366.64 | 1.0 | False | None | None | False | None | False | 5366.64 | 0 | 2983952 | 98972 | None | ELE SR NO 2021-22 Item No 5.19.10 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 pole. | No | 5946.02 | 5946.02 | 2.0 | False | None | None | False | None | False | 11892.04 | 0 | 2983953 | 98972 | None | ELE SR NO 2021-22 Item No 5.21 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.(KPWD ELE SR 2022-23,P.No.14, I.No.5.21) | No | 9812.88 | 9812.88 | 2.0 | False | None | None | False | None | False | 19625.76 | 0 | 2983954 | 98972 | None | ELE SR NO 2021-22 Item No 5.29 | Supplying, fixing and wiring 3 Phase Digital Ammeter /Voltmeter. | No | 1510.4 | 1510.4 | 2.0 | False | None | None | False | None | False | 3020.8 | 0 | 2983955 | 98972 | None | ELE SR NO 2021-22 Item No 5.31 | Supplying and fixing Electronic Trivector Meter (ETV)
suitable for operation LT operation and -CT operated meter in
polycarbonate body in class 0.5 accuracy as per IS 14697 and
completely wired. | Each | 4651.56 | 4651.56 | 1.0 | False | None | None | False | None | False | 4651.56 | 0 | 2983956 | 98972 | None | ELE SR NO 2021-22 Item No 5.33 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy. | No | 9876.6 | 9876.6 | 2.0 | False | None | None | False | None | False | 19753.2 | 0 | 2983957 | 98972 | None | ELE SR NO 2021-22 Item No 5.34 | Supplying, fixing and wiring 50/5 to 400/5Amps 5VA burden Current Transformer. Class 0.5 accuracy with Tape Wound. | No | 595.9 | 595.9 | 6.0 | False | None | None | False | None | False | 3575.4 | 0 | 2983958 | 98972 | None | ELE SR NO 2021-22 Item No 5.38 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.C. | No | 547.52 | 547.52 | 24.0 | False | None | None | False | None | False | 13140.48 | 0 | 2983959 | 98972 | None | ELE SR NO 2021-22 Item No 5.40.1 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.100Amps 4x30x6mm Aluminium Strips. | Mtr | 2612.52 | 2612.52 | 4.0 | False | None | None | False | None | False | 10450.08 | 0 | 2983960 | 98972 | None | ELE SR NO 2021-22 Item No 5.40.2 | Supplying ......... amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete.250Amps 4x30x10mm Aluminium Strips. | Mtr | 3632.04 | 3632.04 | 4.0 | False | None | None | False | None | False | 14528.16 | 0 | 2983961 | 98972 | None | ELE SR NO 2021-22 Item No 5.41.2 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50x50x6mm | Mtr | 420.08 | 420.08 | 12.0 | False | None | None | False | None | False | 5040.96 | 0 | 2983962 | 98972 | None | ELE SR NO 2021-22 Item No 5.41.1 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.40*40*6mm | Mtr | 324.5 | 324.5 | 12.0 | False | None | None | False | None | False | 3894.0 | 0 | 2983963 | 98972 | None | ELE SR NO 2021-22 Item No 5.41.4 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. flat … with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50X100X50X6mm C channel | Mtr | 802.4 | 802.4 | 12.0 | False | None | None | False | None | False | 9628.8 | 0 | 2983964 | 98972 | None | ELE SR NO 2021-22 Item No 5.13.2 | Supplying and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel boaard using necessary bolts,nuts, washers and wiring etc., completee with ac-3 rating and as per IS-13947 40Amps. | No | 2508.68 | 2508.68 | 3.0 | False | None | None | False | None | False | 7526.04 | 0 | 2983965 | 98972 | None | ELE SR NO 2021-22 Item No 5.37 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries likeinduction motor. | Kvar | 509.76 | 509.76 | 15.0 | False | None | None | False | None | False | 7646.4 | 0 | 2983966 | 98972 | None | EL SR No 2021-22 Item No 5.38 | Supplying fixing and wiring Automatic Power Factor controller circuit unit fully static units controlled by 14 stage microprocessor operation relays LED display self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank measurement of network harmonics with indication when limit values are exceeded Comprehensive displays with large three phase LED display Long term memory for settings protection for over voltage power factor correction fault and no voltage to connect disconnect banks with automatic recognition or with standard programs | No | 22939.2 | 22939.2 | 1.0 | False | None | None | False | None | False | 22939.2 | 0 | 2983967 | 98972 | None | ELE SR NO 2021-22 Item No 5.42.1 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 14SWG . | Sq CM | 0.51 | 0.51 | 225000.0 | False | None | None | False | None | False | 114750.0 | 0 | 2983968 | 98972 | None | ELE SR NO 2021-22 Item No 6.2 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 4897.0 | 4897.0 | 6.0 | False | None | None | False | None | False | 29382.0 | 0 | 2983969 | 98972 | None | ELE SR NO 2021-22 Item No 6.3.1 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.GI Strip. 25x3mm. | m | 88.5 | 88.5 | 20.0 | False | None | None | False | None | False | 1770.0 | 0 | 2983970 | 98972 | None | ELE SR NO 2021-22 Item No 6.3.4 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.50x6mm GI strip. | m | 230.1 | 230.1 | 20.0 | False | None | None | False | None | False | 4602.0 | 0 | 2983971 | 98972 | None | ELE SR NO 2021-22 Item No 6.3.6 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Copper strip. 25x3mm. | m | 595.9 | 595.9 | 20.0 | False | None | None | False | None | False | 11918.0 | 0 | 2983972 | 98972 | None | ELE SR NO 2021-22 Item No 6.3.7 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. Copper strip. 25x6mm. | m | 1130.44 | 1130.44 | 20.0 | False | None | None | False | None | False | 22608.8 | 0 | 2983973 | 98972 | None | ELE SR NO 2021-22 Item No 6.3.10 | Fabricating supplying and mounting MS box made out … SWG suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.600x600x3mm Copper plate. | No | 8142.0 | 8142.0 | 6.0 | False | None | None | False | None | False | 48852.0 | 0 | 2983974 | 98972 | None | ELE SR NO 2021-22 Item No 6.18.4 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG. Copper Wire. | m | 68.44 | 68.44 | 50.0 | False | None | None | False | None | False | 3422.0 | 0 | 2983975 | 98972 | None | ELE SR NO 2021-22 Item No 6.17.1 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5sqmm | No | 3.54 | 3.54 | 50.0 | False | None | None | False | None | False | 177.0 | 0 | 2983976 | 98972 | None | ELE SR NO 2021-22 Item No 6.17.2 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm | No | 4.72 | 4.72 | 115.0 | False | None | None | False | None | False | 542.8 | 0 | 2983977 | 98972 | None | ELE SR NO 2021-22 Item No 6.17.3 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm | No | 8.26 | 8.26 | 30.0 | False | None | None | False | None | False | 247.8 | 0 | 2983978 | 98972 | None | ELE SR NO 2021-22 Item No 6.17.4 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6 sqmm | No | 8.26 | 8.26 | 10.0 | False | None | None | False | None | False | 82.6 | 0 | 2983979 | 98972 | None | EL SR No 2021-22 Item No 6.17.5 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes 10 sqm | No | 9.44 | 9.44 | 24.0 | False | None | None | False | None | False | 226.56 | 0 | 2983980 | 98972 | None | ELE SR NO 2021-22 Item No 6.8 | Providing and laying in position 100mm dia stone ware pipe in existing trench. | m | 253.7 | 253.7 | 50.0 | False | None | None | False | None | False | 12685.0 | 0 | 2983981 | 98972 | None | ELE SR NO 2021-22 Item No 6.1 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. 15" Sweep (450mm) | No | 1819.56 | 1819.56 | 8.0 | False | None | None | False | None | False | 14556.48 | 0 | 2983982 | 98972 | None | ELE SR NO 2021-22 Item No 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value more than or equal 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 degC over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty 48" Sweep 5 Star (1200mm) | No | 3479.82 | 3479.82 | 28.0 | False | None | None | False | None | False | 97434.96 | 0 | 2983983 | 98972 | None | ELE SR NO 2021-22 Item No 11.3.1 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x 2' - 9/10w | No | 585.28 | 585.28 | 22.0 | False | None | None | False | None | False | 12876.16 | 0 | 2983984 | 98972 | None | ELE SR NO 2021-22 Item No 11.3.2 | Supplying of ......feet - PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w | No | 873.2 | 873.2 | 92.0 | False | None | None | False | None | False | 80334.4 | 0 | 2983985 | 98972 | None | ELE SR NO 2021-22 Item No 11.5.2 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W | Each | 985.3 | 985.3 | 41.0 | False | None | None | False | None | False | 40397.3 | 0 | 2983986 | 98972 | None | ELE SR NO 2021-22 Item No 11.5.3 | Supply of round/square recess/surface mounted rolling type LED Down light with .......W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI more than 80. Power Input: 220-240V @ 50/60Hz & Power factor more than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 15-18W | Each | 1473.82 | 1473.82 | 4.0 | False | None | None | False | None | False | 5895.28 | 0 | 2983987 | 98972 | None | ELE SR NO 2021-22 Item No 11.11.5 | Supplying & fixing of retrofit type - LED bulb.......W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI more than 70%. efficacy more than 80 lumen per watt, life more than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF more than 0.95, power loss should less than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 12 W, 6500K | Each | 279.66 | 279.66 | 10.0 | False | None | None | False | None | False | 2796.6 | 0 | 2983988 | 98972 | None | ELE SR NO 2021-22 Item No 6.5.1 | Supplying wall mounting fan suitable to operate at singlephase 230v A.C. supply.300mm Sweep | Each | 3124.64 | 3124.64 | 1.0 | False | None | None | False | None | False | 3124.64 | 0 | 2983989 | 98972 | None | ELE SR NO 2021-22 Item No 13.7.1 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders | Each | 140.42 | 140.42 | 159.0 | False | None | None | False | None | False | 22326.78 | 0 | 2983990 | 98972 | None | ELE SR NO 2021-22 Item No 13.11 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 331.58 | 331.58 | 29.0 | False | None | None | False | None | False | 9615.82 | 0 | 2983991 | 98972 | None | ELE SR NO 2021-22 Item No 13.13 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 828.36 | 828.36 | 8.0 | False | None | None | False | None | False | 6626.88 | 0 | 2983992 | 98972 | None | ELE SR NO 2021-22 Item No 11.8.2 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT less than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire less than IK08. Power Factor less than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency more than 130lm/w, nominal CRI more than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osram make LED Source. LED Streetlight 40W | No | 4308.18 | 4308.18 | 4.0 | False | None | None | False | None | False | 17232.72 | 0 | 2983993 | 98972 | None | ELE SR NO 2021-22 Item No 13.2.1 | Supplying and Fixing........mm dia class A GI pipe bracket up to 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed forfixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | No | 1239.0 | 1239.0 | 4.0 | False | None | None | False | None | False | 4956.0 | 0 | 2983994 | 98972 | None | ELE SR NO 2021-22 Item No 13.5 | Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires | No | 223.02 | 223.02 | 4.0 | False | None | None | False | None | False | 892.08 | 0 | 2983995 | 98972 | None | ELE SR NO 2021-22 Item No 7.11 | Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 10 L. | Each | 7646.4 | 7646.4 | 4.0 | False | None | None | False | None | False | 30585.6 | 0 | 2983996 | 98972 | None | ELE SR NO 2021-22 Item No 9.2.5 | Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3density Rock wool insulation with 22SWG Aluminium cladding. 300 L. | Each | 83525.12 | 83525.12 | 1.0 | False | None | None | False | None | False | 83525.12 | 0 | 2983997 | 98972 | None | ELE SR NO 2021-22 Item No 9.2.5 | Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 5 kVA OFF LINE UPS(KPWD ELE SR 2022-23,P.No. 29, I.No.9.2.5) | Each | 45619.98 | 45619.98 | 1.0 | False | None | None | False | None | False | 45619.98 | 0 | 2983998 | 98972 | None | ELE SR NO 2021-22 Item No 9.5.6 | Supplying, installation, testing & commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries80 AH capacity.(KPWD ELE SR 2022-23,P.No. 29, I.No.9.5.6) | Each | 12682.64 | 12682.64 | 6.0 | False | None | None | False | None | False | 76095.84 | 0 | 2983999 | 98972 | None | BESCOM SR PART-3,P.NO-9,It no-32.14 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.150 Sqmm, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm) | Km | 606567.2 | 606567.2 | 0.4 | False | None | None | False | None | False | 242626.88 | 0 | 2984000 | 98972 | None | BESCOM SR PART-4,P.NO-9,It no-31.06 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff.35 to 95 Sqmm | Km | 27903.46 | 27903.46 | 0.4 | False | None | None | False | None | False | 11161.384 | 0 | 2984001 | 98972 | None | BESCOM SR PART-3,P.NO-20,It no-63.01 | Heavy Duty Copper Terminal Long Barrel.25 Sqmm Copper Terminal, Apprx Wt: 11 Gm
| No | 34.22 | 34.22 | 8.0 | False | None | None | False | None | False | 273.76 | 0 | 2984002 | 98972 | None | BESCOM SR PART-3,P.NO-21,It no-63.5 | Heavy Duty Copper Terminal Long Barrel.150 Sqmm Copper Terminal, Apprx Wt: 98 Gm
| No | 156.94 | 156.94 | 8.0 | False | None | None | False | None | False | 1255.52 | 0 | 2984003 | 98972 | None | BESCOM SR PART-3,P.NO-25,It no-70.01 | Brass Cable Gland 25mm
| No | 90.86 | 90.86 | 2.0 | False | None | None | False | None | False | 181.72 | 0 | 2984004 | 98972 | None | BESCOM SR PART-3,P.NO-25,It no-70.02 | Brass Cable Gland 32mm
| No | 109.74 | 109.74 | 2.0 | False | None | None | False | None | False | 219.48 | 0 | 2984005 | 98972 | None | BESCOM SR PART-3,P.NO-25,It no-70.03 | Brass Cable Gland 40mm
| No | 169.92 | 169.92 | 2.0 | False | None | None | False | None | False | 339.84 | 0 | 2984006 | 98972 | None | BESCOM SR PART-3P NO-25It no 70.04 | Brass Cable Gland 45mm
| No | 226.56 | 226.56 | 2.0 | False | None | None | False | None | False | 453.12 | 0 | 2984007 | 98972 | None | SR PART 3 P No15 Iem No 48.08 | PVC Pipe as per IS2509 PVC Pipe 80 mm Dia
| m | 264.32 | 264.32 | 10.0 | False | None | None | False | None | False | 2643.2 | 0 | 2984008 | 98972 | None | PART 4 P No 8 item no 29.02 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr Width and Depth upto 1 Mtr including trial pits depositing on bank upto a lead of 50 Mtr Supplying and Displaying necessary Danger Boards and Lighting Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Ordinary Soil
| CUBIC METER | 306.8 | 306.8 | 75.0 | False | None | None | False | None | False | 23010.0 | 0 | 2984009 | 98972 | None | SR Part-4 P.NO.8 IT No-29.07 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr
| CUBIC METER | 68.44 | 68.44 | 75.0 | False | None | None | False | None | False | 5133.0 | 0 | 2984010 | 98972 | None | ELE SR NO 2021-22 Item No 5.11.3 | Supplying of on load change over switches 4 poles, AC- 23A Duty, 415V, 50Hz, AC Supply. (Open Execution) 125 A
| Each | 10793.46 | 10793.46 | 1.0 | False | None | None | False | None | False | 10793.46 | 0 |
| 1710137476000 | 0 | None | None | Buildings | LIFT | 1549163.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
2984011 | 98973 | None | 14.4.2 | Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,
8 PASSANGER With Out Machine Room-SS Finish WITH 3 STOPS
| Job | 1549163.0 | 1549163.0 | 1.0 | False | None | None | False | None | False | 1549163.0 | 0 |
|
|
---|