2964365 | 97987 | None | BOQ01 | Clearing and grubbing road land including uprooting rankvegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(ii) By Mechanical Means using Dozer | Sqm | 4.13 | 4.13 | 1225.0 | False | None | None | False | None | False | 5059.25 | 0 |
2964366 | 97987 | None | BOQ02 | Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. | Sqm | 185.85 | 185.85 | 1765.0 | False | None | None | False | None | False | 328025.25 | 0 |
2964367 | 97987 | None | BOQ03 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m | Cum | 107.1 | 107.1 | 947.0 | False | None | None | False | None | False | 101423.7 | 0 |
2964368 | 97987 | None | BOQ04 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C./ Lindane 20% E.C.@ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 123.9 | 123.9 | 992.0 | False | None | None | False | None | False | 122908.8 | 0 |
2964369 | 97987 | None | BOQ05 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc.in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 454.65 | 454.65 | 2100.0 | False | None | None | False | None | False | 954765.0 | 0 |
2964370 | 97987 | None | BOQ06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc.in layers not exceeding 20cm in depth,consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 663.102 | False | None | None | False | None | False | 181676.68596 | 0 |
2964371 | 97987 | None | BOQ07 | Providing and Filling in foundation with granite / trap broken metal 100mm.and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 2816.1 | 2816.1 | 78.34 | False | None | None | False | None | False | 220613.274 | 0 |
2964372 | 97987 | None | BOQ08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 189.0 | False | None | None | False | None | False | 1267897.05 | 0 |
2964373 | 97987 | None | BOQ09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 139.44 | False | None | None | False | None | False | 876861.468 | 0 |
2964374 | 97987 | None | BOQ10 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates-FOOTING M25Design Mix Using 20 mm nominal size graded crushed coarse aggregates- Including formwork charges for Footing etc.., Complete including with all lead , lift & asper the directions of Engineer In Charge of the work. | Cum | 7185.02 | 7185.02 | 98.2 | False | None | None | False | None | False | 705568.964 | 0 |
2964375 | 97987 | None | BOQ11 | do columns upto plinth (Including formwork charges). | Cum | 11309.76 | 11309.76 | 22.3729 | False | None | None | False | None | False | 253032.129504 | 0 |
2964376 | 97987 | None | BOQ12 | do Plinth Beam (Including formwork charges). | Cum | 9979.2 | 9979.2 | 31.05 | False | None | None | False | None | False | 309854.16 | 0 |
2964377 | 97987 | None | BOQ13 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevantIS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical
specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8981.28 | 8981.28 | 31.2 | False | None | None | False | None | False | 280215.936 | 0 |
2964378 | 97987 | None | BOQ14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges) | Cum | 12214.76 | 12214.76 | 23.85 | False | None | None | False | None | False | 291322.026 | 0 |
2964379 | 97987 | None | BOQ15 | do columns First Floor (Including formwork charges). | Cum | 12336.9 | 12336.9 | 23.85 | False | None | None | False | None | False | 294235.065 | 0 |
2964380 | 97987 | None | BOQ16 | do columns Second Floor (Including formwork charges). | Cum | 12460.27 | 12460.27 | 23.85 | False | None | None | False | None | False | 297177.4395 | 0 |
2964381 | 97987 | None | BOQ17 | do columns Terrace Floor (Including formwork charges). | Cum | 12584.87 | 12584.87 | 1.242 | False | None | None | False | None | False | 15630.40854 | 0 |
2964382 | 97987 | None | BOQ18 | do beams Ground Floor (Including formwork charges). | Cum | 11496.24 | 11496.24 | 45.13 | False | None | None | False | None | False | 518825.3112 | 0 |
2964383 | 97987 | None | BOQ19 | do beams First Floor (Including formwork charges). | Cum | 11611.2 | 11611.2 | 44.8 | False | None | None | False | None | False | 520181.76 | 0 |
2964384 | 97987 | None | BOQ20 | do beams Second Floor (Including formwork charges). | Cum | 11727.31 | 11727.31 | 44.8 | False | None | None | False | None | False | 525383.488 | 0 |
2964385 | 97987 | None | BOQ21 | do beams Terrace Floor (Including formwork charges). | Cum | 11844.58 | 11844.58 | 1.66 | False | None | None | False | None | False | 19662.0028 | 0 |
2964386 | 97987 | None | BOQ22 | do slab Ground Floor (Including formwork charges). | Cum | 10777.73 | 10777.73 | 72.6 | False | None | None | False | None | False | 782463.198 | 0 |
2964387 | 97987 | None | BOQ23 | do slab First Floor (Including formwork charges). | Cum | 10885.5 | 10885.5 | 72.6 | False | None | None | False | None | False | 790287.3 | 0 |
2964388 | 97987 | None | BOQ24 | do slab Second Floor (Including formwork charges). | Cum | 10994.36 | 10994.36 | 72.6 | False | None | None | False | None | False | 798190.536 | 0 |
2964389 | 97987 | None | BOQ25 | do slab Terrace Floor (Including formwork charges).( | Cum | 11104.3 | 11104.3 | 2.362 | False | None | None | False | None | False | 26228.3566 | 0 |
2964390 | 97987 | None | BOQ26 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, Cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings-Foundation work | Kg | 93.93 | 93.93 | 18272.29 | False | None | None | False | None | False | 1716316.1997 | 0 |
2964391 | 97987 | None | BOQ27 | Do-TMT reinforcement Ground Floor | Kg | 93.93 | 93.93 | 14157.9 | False | None | None | False | None | False | 1329851.547 | 0 |
2964392 | 97987 | None | BOQ28 | Do-TMT reinforcement First Floor | Kg | 94.87 | 94.87 | 14124.57 | False | None | None | False | None | False | 1339997.9559 | 0 |
2964393 | 97987 | None | BOQ29 | Do-TMT reinforcement Second Floor | Kg | 95.82 | 95.82 | 14124.57 | False | None | None | False | None | False | 1353416.2974 | 0 |
2964394 | 97987 | None | BOQ30 | Do-TMT reinforcement Terrace Floor | Kg | 96.78 | 96.78 | 526.05 | False | None | None | False | None | False | 50911.119 | 0 |
2964395 | 97987 | None | BOQ31 | Providing brickwork with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.do-Ground Floor | Cum | 8632.05 | 8632.05 | 21.114 | False | None | None | False | None | False | 182257.1037 | 0 |
2964396 | 97987 | None | BOQ32 | do- First Floor Brick work | Cum | 8718.37 | 8718.37 | 158.94 | False | None | None | False | None | False | 1385697.7278 | 0 |
2964397 | 97987 | None | BOQ33 | do-Second Floor Brick work | Cum | 8805.55 | 8805.55 | 158.94 | False | None | None | False | None | False | 1399554.117 | 0 |
2964398 | 97987 | None | BOQ34 | do-Terrace Floor Brick work | Cum | 8893.61 | 8893.61 | 55.982 | False | None | None | False | None | False | 497882.07502 | 0 |
2964399 | 97987 | None | BOQ35 | Providing 12 mm cement plaster (ceiling surface) with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.do-Ground Floor | Sqm | 267.75 | 267.75 | 484.0 | False | None | None | False | None | False | 129591.0 | 0 |
2964400 | 97987 | None | BOQ36 | do- First Floor ceiling Plastering | Sqm | 270.43 | 270.43 | 380.0 | False | None | None | False | None | False | 102763.4 | 0 |
2964401 | 97987 | None | BOQ37 | do-Second Floor ceiling Plastering | Sqm | 273.13 | 273.13 | 380.0 | False | None | None | False | None | False | 103789.4 | 0 |
2964402 | 97987 | None | BOQ38 | do-Terrace Floor ceiling Plastering | Sqm | 275.86 | 275.86 | 10.66 | False | None | None | False | None | False | 2940.6676 | 0 |
2964403 | 97987 | None | BOQ39 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.-Ground Floor | Sqm | 366.45 | 366.45 | 380.64 | False | None | None | False | None | False | 139485.528 | 0 |
2964404 | 97987 | None | BOQ40 | do- First Floor Internal surface Plastering | Sqm | 370.11 | 370.11 | 1251.92 | False | None | None | False | None | False | 463348.1112 | 0 |
2964405 | 97987 | None | BOQ41 | do-Second Floor Internal surface Plastering | Sqm | 373.82 | 373.82 | 1251.92 | False | None | None | False | None | False | 467992.7344 | 0 |
2964406 | 97987 | None | BOQ42 | do-Terrace Floor Internal surface Plastering | Sqm | 377.55 | 377.55 | 40.2 | False | None | None | False | None | False | 15177.51 | 0 |
2964407 | 97987 | None | BOQ43 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.do-Ground Floor | Sqm | 105.0 | 105.0 | 380.64 | False | None | None | False | None | False | 39967.2 | 0 |
2964408 | 97987 | None | BOQ44 | do- First Floor putty | Sqm | 106.05 | 106.05 | 1251.92 | False | None | None | False | None | False | 132766.116 | 0 |
2964409 | 97987 | None | BOQ45 | do-Second Floor putty | Sqm | 107.11 | 107.11 | 1251.92 | False | None | None | False | None | False | 134093.1512 | 0 |
2964410 | 97987 | None | BOQ46 | do-Terrace Floor putty | Sqm | 108.18 | 108.18 | 40.2 | False | None | None | False | None | False | 4348.836 | 0 |
2964411 | 97987 | None | BOQ47 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.do-Ground Floor | Sqm | 55.65 | 55.65 | 380.64 | False | None | None | False | None | False | 21182.616 | 0 |
2964412 | 97987 | None | BOQ48 | do- First Floor primer | Sqm | 56.21 | 56.21 | 1251.92 | False | None | None | False | None | False | 70370.4232 | 0 |
2964413 | 97987 | None | BOQ49 | do-Second Floor primer | Sqm | 56.77 | 56.77 | 1251.92 | False | None | None | False | None | False | 71071.4984 | 0 |
2964414 | 97987 | None | BOQ50 | do-Terrace Floor primer | Sqm | 57.34 | 57.34 | 40.2 | False | None | None | False | None | False | 2305.068 | 0 |
2964415 | 97987 | None | BOQ51 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats as per specifications and as per directions of Engineer in charge.-Ground Floor | Sqm | 115.5 | 115.5 | 380.64 | False | None | None | False | None | False | 43963.92 | 0 |
2964416 | 97987 | None | BOQ52 | do- First Floor acrylic emulsion paint | Sqm | 116.66 | 116.66 | 1251.92 | False | None | None | False | None | False | 146048.9872 | 0 |
2964417 | 97987 | None | BOQ53 | do-Second Floor acrylic emulsion paint | Sqm | 117.82 | 117.82 | 1251.92 | False | None | None | False | None | False | 147501.2144 | 0 |
2964418 | 97987 | None | BOQ54 | do-Terrace Floor acrylic emulsion paint | Sqm | 119.0 | 119.0 | 40.2 | False | None | None | False | None | False | 4783.8 | 0 |
2964419 | 97987 | None | BOQ55 | Providing 20 mm cement plaster (external surface) of mix :1:4 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.do-Ground Floor | Sqm | 371.7 | 371.7 | 312.4 | False | None | None | False | None | False | 116119.08 | 0 |
2964420 | 97987 | None | BOQ56 | do- First Floor | Sqm | 375.42 | 375.42 | 612.0 | False | None | None | False | None | False | 229757.04 | 0 |
2964421 | 97987 | None | BOQ57 | do-Second Floor | Sqm | 379.17 | 379.17 | 612.0 | False | None | None | False | None | False | 232052.04 | 0 |
2964422 | 97987 | None | BOQ58 | do-Terrace Floor | Sqm | 382.96 | 382.96 | 536.32 | False | None | None | False | None | False | 205389.1072 | 0 |
2964423 | 97987 | None | BOQ59 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.do-Ground Floor | Sqm | 182.7 | 182.7 | 312.4 | False | None | None | False | None | False | 57075.48 | 0 |
2964424 | 97987 | None | BOQ60 | do- First Floor | Sqm | 184.53 | 184.53 | 612.0 | False | None | None | False | None | False | 112932.36 | 0 |
2964425 | 97987 | None | BOQ61 | do-Second Floor | Sqm | 186.37 | 186.37 | 612.0 | False | None | None | False | None | False | 114058.44 | 0 |
2964426 | 97987 | None | BOQ62 | do-Terrace Floor | Sqm | 188.24 | 188.24 | 536.32 | False | None | None | False | None | False | 100956.8768 | 0 |
2964427 | 97987 | None | BOQ63 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete..Size of Tile 600x600 mm do-First Floor | Sqm | 1246.09 | 1246.09 | 305.45 | False | None | None | False | None | False | 380618.1905 | 0 |
2964428 | 97987 | None | BOQ64 | do-Second Floor vitrified floor | Sqm | 1258.55 | 1258.55 | 302.3 | False | None | None | False | None | False | 380459.665 | 0 |
2964429 | 97987 | None | BOQ65 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc.all complete as specified and as directed by the Engineer-in-Charge.do-do- First Floor | Sqm | 2738.21 | 2738.21 | 50.0 | False | None | None | False | None | False | 136910.5 | 0 |
2964430 | 97987 | None | BOQ66 | do- Second Floor | Sqm | 2765.59 | 2765.59 | 50.0 | False | None | None | False | None | False | 138279.5 | 0 |
2964431 | 97987 | None | BOQ67 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.do-Ground Floor | Sqm | 5594.4 | 5594.4 | 18.7 | False | None | None | False | None | False | 104615.28 | 0 |
2964432 | 97987 | None | BOQ68 | do- First Floor | Sqm | 5650.34 | 5650.34 | 18.7 | False | None | None | False | None | False | 105661.358 | 0 |
2964433 | 97987 | None | BOQ69 | do- Second Floor | Sqm | 5706.84 | 5706.84 | 18.7 | False | None | None | False | None | False | 106717.908 | 0 |
2964434 | 97987 | None | BOQ70 | Providing full nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification. | Mtr | 299.88 | 299.88 | 250.0 | False | None | None | False | None | False | 74970.0 | 0 |
2964435 | 97987 | None | BOQ71 | Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS: 15622 (thickness to be specified by the manufacturer), ofapproved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer- in-Charge, in skirting,risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per m2, including pointing in white cement mixed with pigmentof matching shade complete.do-First Floor | Sqm | 1172.91 | 1172.91 | 198.95 | False | None | None | False | None | False | 233350.4445 | 0 |
2964436 | 97987 | None | BOQ72 | do- Second Floor ceramic glazed wall tiles | Sqm | 1184.64 | 1184.64 | 198.95 | False | None | None | False | None | False | 235684.128 | 0 |
2964437 | 97987 | None | BOQ73 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete.do-First floor | Sqm | 942.78 | 942.78 | 35.04 | False | None | None | False | None | False | 33035.0112 | 0 |
2964438 | 97987 | None | BOQ74 | do- Second Floor Ceramic glazed floor tile | Sqm | 952.21 | 952.21 | 35.04 | False | None | None | False | None | False | 33365.4384 | 0 |
2964439 | 97987 | None | BOQ75 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications | Cum | 2117.85 | 2117.85 | 3.52 | False | None | None | False | None | False | 7454.832 | 0 |
2964440 | 97987 | None | BOQ76 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. | Sqm | 840.0 | 840.0 | 400.0 | False | None | None | False | None | False | 336000.0 | 0 |
2964441 | 97987 | None | BOQ77 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge etc., complete with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., | Sqm | 857.85 | 857.85 | 558.0 | False | None | None | False | None | False | 478680.3 | 0 |
2964442 | 97987 | None | BOQ78 | Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 532.35 | 532.35 | 50.0 | False | None | None | False | None | False | 26617.5 | 0 |
2964443 | 97987 | None | BOQ79 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 144977.7 | 144977.7 | 1.35 | False | None | None | False | None | False | 195719.895 | 0 |
2964444 | 97987 | None | BOQ80 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991.from manufacturer complete as per spcification.--do- 30 mm thick one side teak and one side commercial | Sqm | 3667.65 | 3667.65 | 63.84 | False | None | None | False | None | False | 234142.776 | 0 |
2964445 | 97987 | None | BOQ81 | Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1.The surface to be polished is rubbed with sand paper 80/120 no.and then with sand paper of 160/180 nos.2.Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3.On drying of sealer coat, wet rubbing with emery cloth of finergrading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc.Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4.On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. | Sqm | 710.85 | 710.85 | 127.68 | False | None | None | False | None | False | 90761.328 | 0 |
2964446 | 97987 | None | BOQ82 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete. | Nos | 1104.6 | 1104.6 | 32.0 | False | None | None | False | None | False | 35347.2 | 0 |
2964447 | 97987 | None | BOQ83 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc.complete. | Nos | 126.0 | 126.0 | 32.0 | False | None | None | False | None | False | 4032.0 | 0 |
2964448 | 97987 | None | BOQ84 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc.complete | Nos | 248.85 | 248.85 | 64.0 | False | None | None | False | None | False | 15926.4 | 0 |
2964449 | 97987 | None | BOQ85 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc.complete :250x10mm | Nos | 456.75 | 456.75 | 64.0 | False | None | None | False | None | False | 29232.0 | 0 |
2964450 | 97987 | None | BOQ86 | Providing and fixing bright finished brass butt hinges with necessary screws etc.complete 125x85x5.5 mm (heavy type) | Nos | 288.75 | 288.75 | 128.0 | False | None | None | False | None | False | 36960.0 | 0 |
2964451 | 97987 | None | BOQ87 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. | Nos | 1066.8 | 1066.8 | 32.0 | False | None | None | False | None | False | 34137.6 | 0 |
2964452 | 97987 | None | BOQ88 | Providing & fixing Factory made single extruded Wood Polymer Composite (WPC) solid door/window, clerestory windows & frames /chowkhat of frame size 65 x 100mm | Mtr | 737.1 | 737.1 | 93.6 | False | None | None | False | None | False | 68992.56 | 0 |
2964453 | 97987 | None | BOQ89 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thickness (KPWD SR 2023-2024/Vol 2/Item No:12.94.2 Pg.No:112 ) | Sqm | 4243.05 | 4243.05 | 19.5 | False | None | None | False | None | False | 82739.475 | 0 |
2964454 | 97987 | None | BOQ90 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash.Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm.Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock.Wall thickness of frame & sash shall be of 2-2.5 mm.Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 5659.5 | 5659.5 | 58.32 | False | None | None | False | None | False | 330062.04 | 0 |
2964455 | 97987 | None | BOQ91 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.The frame having overall size of 39mm x39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.Wall thickness of frame shall be2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) etc.,with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work. | Sqm | 6004.95 | 6004.95 | 5.76 | False | None | None | False | None | False | 34588.512 | 0 |
2964456 | 97987 | None | BOQ92 | Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats, square or round bars etc.including priming coat with approved steel primer all complete.Fixed to steel windows by welding | Kg | 176.4 | 176.4 | 1283.0 | False | None | None | False | None | False | 226321.2 | 0 |
2964457 | 97987 | None | BOQ93 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 175.35 | 175.35 | 65.0 | False | None | None | False | None | False | 11397.75 | 0 |
2964458 | 97987 | None | BOQ94 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. | Kg | 593.25 | 593.25 | 606.0 | False | None | None | False | None | False | 359509.5 | 0 |
2964459 | 97987 | None | BOQ95 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 154.35 | 154.35 | 700.0 | False | None | None | False | None | False | 108045.0 | 0 |
2964460 | 97987 | None | BOQ96 | Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure.The work including cost of all materials, labour charges, and hire charges of machinery for cutting, welding, grinding and erection equipments, with all lead and lifts, transportation, loading and unloading and all other incidental charges etc.complete as per specification and directions of the engineer in charge of the work. | Sqm | 3281.25 | 3281.25 | 9.0 | False | None | None | False | None | False | 29531.25 | 0 |
2964461 | 97987 | None | BOQ97 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8689.8 | 8689.8 | 9.0 | False | None | None | False | None | False | 78208.2 | 0 |
2964462 | 97987 | None | BOQ98 | Providing and fixing 1mm thick M.S.sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S.gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using M.S.angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4701.9 | 4701.9 | 19.36 | False | None | None | False | None | False | 91028.784 | 0 |
2964463 | 97987 | None | BOQ99 | Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grademarine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately) | Sqm | 3108.0 | 3108.0 | 50.88 | False | None | None | False | None | False | 158135.04 | 0 |
2964464 | 97987 | None | BOQ100 | Providing and supplying 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc.including necessary nails,screws etc.complete as per direction of Engineer-in-charge. | Sqm | 1165.5 | 1165.5 | 76.32 | False | None | None | False | None | False | 88950.96 | 0 |
2964465 | 97987 | None | BOQ101 | Labour & installation charges for BWP ply:BWR ply:HDHMR: MDF & Particle board work of any thickness applicable for all types of work | Sqm | 2100.0 | 2100.0 | 127.2 | False | None | None | False | None | False | 267120.0 | 0 |
2964466 | 97987 | None | BOQ102 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc.complete as per direction of Engineer-in charge.200mm length | Nos | 1575.0 | 1575.0 | 32.0 | False | None | None | False | None | False | 50400.0 | 0 |
2964467 | 97987 | None | BOQ103 | Providing and fixing Stainless Steel 304 grade soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc.complete as per direction of Engineer-in-charge. | Nos | 420.0 | 420.0 | 16.0 | False | None | None | False | None | False | 6720.0 | 0 |
2964468 | 97987 | None | BOQ104 | Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc complete as per direction of Engineer-in-charge | Nos | 273.0 | 273.0 | 32.0 | False | None | None | False | None | False | 8736.0 | 0 |
2964469 | 97987 | None | BOQ105 | Providing and fixing stainless steel 304 grade soft closing hinges with two hole fixing & 165 degrees turning option for wardrobe doors , kitchen & other utilities of reputed make with screws etc complete as per direction of Engineer-in-charge | Nos | 236.25 | 236.25 | 16.0 | False | None | None | False | None | False | 3780.0 | 0 |
2964470 | 97987 | None | BOQ106 | Providing and laying (Kitchen slab) flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over wooden wadrobe with pigment of matching shade including polishing etc.all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent | Sqm | 2589.3 | 2589.3 | 36.0 | False | None | None | False | None | False | 93214.8 | 0 |
2964471 | 97987 | None | BOQ107 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar loca tions of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc.complete at all levels.Area of slab over 0.50 m2 | Sqm | 4133.85 | 4133.85 | 30.0 | False | None | None | False | None | False | 124015.5 | 0 |
2964472 | 97987 | None | BOQ108 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge. | Mtr | 344.4 | 344.4 | 40.0 | False | None | None | False | None | False | 13776.0 | 0 |
2964473 | 97987 | None | BOQ109 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc.including moulding, rubbing and polishing of cut edges etc complete | Each | 620.55 | 620.55 | 8.0 | False | None | None | False | None | False | 4964.4 | 0 |
2964474 | 97987 | None | BOQ110 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per iS:13983 with C.I.brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm | Each | 5898.9 | 5898.9 | 8.0 | False | None | None | False | None | False | 47191.2 | 0 |
2964475 | 97987 | None | BOQ111 | Plant Mix Method Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -II Material | Cum | 2688.0 | 2688.0 | 215.99 | False | None | None | False | None | False | 580581.12 | 0 |
2964476 | 97987 | None | BOQ112 | Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base.The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work).Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. | Cum | 7112.7 | 7112.7 | 144.0 | False | None | None | False | None | False | 1024228.8 | 0 |
2964477 | 97987 | None | BOQ113 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge..600 x 300 x 150 mm Kerb Stone | Mtr | 486.15 | 486.15 | 240.0 | False | None | None | False | None | False | 116676.0 | 0 |
2964478 | 97987 | None | BOQ114 | Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T.hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S.flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge. | Each | 1179.15 | 1179.15 | 225.0 | False | None | None | False | None | False | 265308.75 | 0 |
2964479 | 97987 | None | BOQ115 | Fabricating, supplying and erection of...ms long hot dip Galvanized Octagonal hot dip Pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 6m Pole in single section andsingle joint welded as per IS 9595/IS10178AWS having dimensions bottom 130....mm , top 70...mm with 3 mm thick, suitable base plate and 4Nos of 450mm..long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc., (excluding foundation) as per drawing appended.6 m - Top 70 mm and Bottom 130 mm dia. | Each | 11800.0 | 11800.0 | 10.0 | False | None | None | False | None | False | 118000.0 | 0 |
2964480 | 97987 | None | BOQ116 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete 2.00 HP/1.5KW, 12 STG. | Each | 18498.9 | 18498.9 | 2.0 | False | None | None | False | None | False | 36997.8 | 0 |
2964481 | 97987 | None | BOQ117 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No.MCB 1 No.DOL of S/D Starter suitable for respective HP 1 No.Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc.complete.Upto 3 HP pumps | Each | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 |
2964482 | 97987 | None | BOQ118 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. | Ltr | 9.45 | 9.45 | 4000.0 | False | None | None | False | None | False | 37800.0 | 0 |
2964483 | 97987 | None | BOQ119 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms.with soft gravel or selected earth available from the excavation etc.complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete For: PVC pipes 140mm dia., 6 kg/sqcm & class 3 | Mtr | 613.2 | 613.2 | 180.0 | False | None | None | False | None | False | 110376.0 | 0 |
2964484 | 97987 | None | BOQ120 | PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 431.55 | 431.55 | 110.0 | False | None | None | False | None | False | 47470.5 | 0 |
2964485 | 97987 | None | BOQ121 | PVC pipes 75mm dia., 6 kg/sqcm & class 3 | Mtr | 231.0 | 231.0 | 230.0 | False | None | None | False | None | False | 53130.0 | 0 |
2964486 | 97987 | None | BOQ122 | Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete.140mm dia PVC couplers | Nos | 229.95 | 229.95 | 25.0 | False | None | None | False | None | False | 5748.75 | 0 |
2964487 | 97987 | None | BOQ123 | b.110 mm dia PVC couplers | Nos | 179.55 | 179.55 | 25.0 | False | None | None | False | None | False | 4488.75 | 0 |
2964488 | 97987 | None | BOQ124 | c.75 mm dia PVC couplers | Nos | 70.35 | 70.35 | 25.0 | False | None | None | False | None | False | 1758.75 | 0 |
2964489 | 97987 | None | BOQ125 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC Elbows | Nos | 374.85 | 374.85 | 25.0 | False | None | None | False | None | False | 9371.25 | 0 |
2964490 | 97987 | None | BOQ126 | b.110 mm dia PVC Elbows | Nos | 317.1 | 317.1 | 25.0 | False | None | None | False | None | False | 7927.5 | 0 |
2964491 | 97987 | None | BOQ127 | c.75 mm dia PVC Elbows | Nos | 201.6 | 201.6 | 25.0 | False | None | None | False | None | False | 5040.0 | 0 |
2964492 | 97987 | None | BOQ128 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC Tee | Nos | 375.9 | 375.9 | 25.0 | False | None | None | False | None | False | 9397.5 | 0 |
2964493 | 97987 | None | BOQ129 | b.110 mm dia PVC Tee | Nos | 263.55 | 263.55 | 25.0 | False | None | None | False | None | False | 6588.75 | 0 |
2964494 | 97987 | None | BOQ130 | c.75 mm dia PVC Tee | Nos | 122.85 | 122.85 | 25.0 | False | None | None | False | None | False | 3071.25 | 0 |
2964495 | 97987 | None | BOQ131 | Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC BEND | Nos | 626.85 | 626.85 | 25.0 | False | None | None | False | None | False | 15671.25 | 0 |
2964496 | 97987 | None | BOQ132 | b.110 mm dia PVC BEND | Nos | 516.6 | 516.6 | 25.0 | False | None | None | False | None | False | 12915.0 | 0 |
2964497 | 97987 | None | BOQ133 | c.75 mm dia PVC BEND | Nos | 257.25 | 257.25 | 25.0 | False | None | None | False | None | False | 6431.25 | 0 |
2964498 | 97987 | None | BOQ134 | Supply and delivery at site special moulded variety PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC BEND | Nos | 336.0 | 336.0 | 25.0 | False | None | None | False | None | False | 8400.0 | 0 |
2964499 | 97987 | None | BOQ135 | b.110 mm dia PVC BEND | Nos | 274.05 | 274.05 | 25.0 | False | None | None | False | None | False | 6851.25 | 0 |
2964500 | 97987 | None | BOQ136 | c.75 mm dia PVC BEND | Nos | 109.2 | 109.2 | 25.0 | False | None | None | False | None | False | 2730.0 | 0 |
2964501 | 97987 | None | BOQ137 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia Pipes | Mtr | 562.8 | 562.8 | 80.0 | False | None | None | False | None | False | 45024.0 | 0 |
2964502 | 97987 | None | BOQ138 | b.32 mm nominal dia Pipes | Mtr | 420.0 | 420.0 | 80.0 | False | None | None | False | None | False | 33600.0 | 0 |
2964503 | 97987 | None | BOQ139 | c.25 mm nominal dia Pipes | Mtr | 333.9 | 333.9 | 360.0 | False | None | None | False | None | False | 120204.0 | 0 |
2964504 | 97987 | None | BOQ140 | d.20 mm nominal dia Pipes | Mtr | 254.1 | 254.1 | 80.0 | False | None | None | False | None | False | 20328.0 | 0 |
2964505 | 97987 | None | BOQ141 | Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) :25 mm nominal bore | Nos | 576.45 | 576.45 | 5.0 | False | None | None | False | None | False | 2882.25 | 0 |
2964506 | 97987 | None | BOQ142 | b.35 mm nominal bore | Nos | 627.9 | 627.9 | 5.0 | False | None | None | False | None | False | 3139.5 | 0 |
2964507 | 97987 | None | BOQ143 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore | Nos | 651.0 | 651.0 | 10.0 | False | None | None | False | None | False | 6510.0 | 0 |
2964508 | 97987 | None | BOQ144 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C.pan with ISI marked white solid plastic seat and lid | Each | 6275.85 | 6275.85 | 8.0 | False | None | None | False | None | False | 50206.8 | 0 |
2964509 | 97987 | None | BOQ145 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C.flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C.pan of size 580x440 mm withintegral type foot rests | Each | 5128.2 | 5128.2 | 8.0 | False | None | None | False | None | False | 41025.6 | 0 |
2964510 | 97987 | None | BOQ146 | Providing and fixing wash basin with C.I.brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer | Each | 4327.05 | 4327.05 | 16.0 | False | None | None | False | None | False | 69232.8 | 0 |
2964511 | 97987 | None | BOQ147 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Each | 850.5 | 850.5 | 16.0 | False | None | None | False | None | False | 13608.0 | 0 |
2964512 | 97987 | None | BOQ148 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. | Each | 5840.1 | 5840.1 | 8.0 | False | None | None | False | None | False | 46720.8 | 0 |
2964513 | 97987 | None | BOQ149 | Providing and fixing 100 mm sand cast Iron grating for gully trap. | Each | 49.35 | 49.35 | 20.0 | False | None | None | False | None | False | 987.0 | 0 |
2964514 | 97987 | None | BOQ150 | Providing and fixing brass bib cock of approved quality :20 mm nominal bore | Each | 320.25 | 320.25 | 32.0 | False | None | None | False | None | False | 10248.0 | 0 |
2964515 | 97987 | None | BOQ151 | Providing and fixing brass stop cock of approved quality :20 mm nominal bore | Each | 320.25 | 320.25 | 16.0 | False | None | None | False | None | False | 5124.0 | 0 |
2964516 | 97987 | None | BOQ152 | Providing 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 520.8 | 520.8 | 16.0 | False | None | None | False | None | False | 8332.8 | 0 |
2964517 | 97987 | None | BOQ153 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete. | Each | 1281.0 | 1281.0 | 16.0 | False | None | None | False | None | False | 20496.0 | 0 |
2964518 | 97987 | None | BOQ154 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc.excluding the cost of CI frame and cover. | Each | 5030.55 | 5030.55 | 5.0 | False | None | None | False | None | False | 25152.75 | 0 |
2964519 | 97987 | None | BOQ155 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc.excluding the cost of CI frame and cover. | Each | 5726.7 | 5726.7 | 5.0 | False | None | None | False | None | False | 28633.5 | 0 |
2964520 | 97987 | None | BOQ156 | Providing and fixing kitchen sink including making all connections including cost of fittings with White glazed fire clay sink of size 600x450x250 mm | Each | 2063.25 | 2063.25 | 8.0 | False | None | None | False | None | False | 16506.0 | 0 |
2964521 | 97987 | None | BOQ157 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 |
2964522 | 97987 | None | BOQ158 | Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary-19/20mm dia 2mm thick. | Mtr | 66.0 | 66.0 | 600.0 | False | None | None | False | None | False | 39600.0 | 0 |
2964523 | 97987 | None | BOQ159 | Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary- 25mm dia 2mm thick | Mtr | 78.0 | 78.0 | 880.0 | False | None | None | False | None | False | 68640.0 | 0 |
2964524 | 97987 | None | BOQ160 | Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-19/20mm dia 2mm thick. | Mtr | 68.0 | 68.0 | 400.0 | False | None | None | False | None | False | 27200.0 | 0 |
2964525 | 97987 | None | BOQ161 | Supplying heavy gauge PVC Conduit Pipe 25mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-25mm dia 2mm thick. | Mtr | 79.0 | 79.0 | 520.0 | False | None | None | False | None | False | 41080.0 | 0 |
2964526 | 97987 | None | BOQ162 | Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required.20mm size | Mtr | 28.0 | 28.0 | 80.0 | False | None | None | False | None | False | 2240.0 | 0 |
2964527 | 97987 | None | BOQ163 | Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required.25mm size | Mtr | 35.0 | 35.0 | 80.0 | False | None | None | False | None | False | 2800.0 | 0 |
2964528 | 97987 | None | BOQ164 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated withsufficient loose length in a wood/PVC round block.complete for Each outlet.-Short point upto 3M from tapping point to out let via switch. | Point | 285.0 | 285.0 | 40.0 | False | None | None | False | None | False | 11400.0 | 0 |
2964529 | 97987 | None | BOQ165 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated withsufficient loose length in a wood/PVC round block.complete for Each outlet.-Medium point above 3M upto 6M from tapping point to out let via switch. | Point | 394.0 | 394.0 | 80.0 | False | None | None | False | None | False | 31520.0 | 0 |
2964530 | 97987 | None | BOQ166 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated withsufficient loose length in a wood/PVC round block.complete for Each outlet.Long point above 6M upto 10M from tapping point to out let via switch. | Point | 570.0 | 570.0 | 162.0 | False | None | None | False | None | False | 92340.0 | 0 |
2964531 | 97987 | None | BOQ167 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall -3 way. | Each | 159.0 | 159.0 | 88.0 | False | None | None | False | None | False | 13992.0 | 0 |
2964532 | 97987 | None | BOQ168 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 4-5 way. | Each | 177.0 | 177.0 | 32.0 | False | None | None | False | None | False | 5664.0 | 0 |
2964533 | 97987 | None | BOQ169 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 6way. | Each | 220.0 | 220.0 | 22.0 | False | None | None | False | None | False | 4840.0 | 0 |
2964534 | 97987 | None | BOQ170 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 8way. | Each | 261.0 | 261.0 | 16.0 | False | None | None | False | None | False | 4176.0 | 0 |
2964535 | 97987 | None | BOQ171 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall- 10-12way. | Each | 319.0 | 319.0 | 82.0 | False | None | None | False | None | False | 26158.0 | 0 |
2964536 | 97987 | None | BOQ172 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 1-3 module. | Each | 161.0 | 161.0 | 88.0 | False | None | None | False | None | False | 14168.0 | 0 |
2964537 | 97987 | None | BOQ173 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 4 module. | Each | 175.0 | 175.0 | 32.0 | False | None | None | False | None | False | 5600.0 | 0 |
2964538 | 97987 | None | BOQ174 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 6 module. | Each | 234.0 | 234.0 | 22.0 | False | None | None | False | None | False | 5148.0 | 0 |
2964539 | 97987 | None | BOQ175 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 8 module. | Each | 284.0 | 284.0 | 16.0 | False | None | None | False | None | False | 4544.0 | 0 |
2964540 | 97987 | None | BOQ176 | Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 10-12 module | Each | 344.0 | 344.0 | 82.0 | False | None | None | False | None | False | 28208.0 | 0 |
2964541 | 97987 | None | BOQ177 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.6Amps one way Switch. | Each | 102.0 | 102.0 | 472.0 | False | None | None | False | None | False | 48144.0 | 0 |
2964542 | 97987 | None | BOQ178 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6Amps two way Switch. | Each | 166.0 | 166.0 | 40.0 | False | None | None | False | None | False | 6640.0 | 0 |
2964543 | 97987 | None | BOQ179 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6Amps 3way socket. | Each | 171.0 | 171.0 | 232.0 | False | None | None | False | None | False | 39672.0 | 0 |
2964544 | 97987 | None | BOQ180 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.-Stepped Fan Regulator. | Each | 357.0 | 357.0 | 48.0 | False | None | None | False | None | False | 17136.0 | 0 |
2964545 | 97987 | None | BOQ181 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6/16Amps One way switch | Each | 180.0 | 180.0 | 56.0 | False | None | None | False | None | False | 10080.0 | 0 |
2964546 | 97987 | None | BOQ182 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6/16Amps universal socket. | Each | 236.0 | 236.0 | 56.0 | False | None | None | False | None | False | 13216.0 | 0 |
2964547 | 97987 | None | BOQ183 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6Amps Bell Push. | Each | 177.0 | 177.0 | 8.0 | False | None | None | False | None | False | 1416.0 | 0 |
2964548 | 97987 | None | BOQ184 | Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. | Each | 246.0 | 246.0 | 8.0 | False | None | None | False | None | False | 1968.0 | 0 |
2964549 | 97987 | None | BOQ185 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.TV/Telephone socket. | Each | 156.0 | 156.0 | 32.0 | False | None | None | False | None | False | 4992.0 | 0 |
2964550 | 97987 | None | BOQ186 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable.2 pair | Mtr | 21.0 | 21.0 | 120.0 | False | None | None | False | None | False | 2520.0 | 0 |
2964551 | 97987 | None | BOQ187 | Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6. | Mtr | 44.0 | 44.0 | 300.0 | False | None | None | False | None | False | 13200.0 | 0 |
2964552 | 97987 | None | BOQ188 | Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.TV/ socket.( | Each | 156.0 | 156.0 | 32.0 | False | None | None | False | None | False | 4992.0 | 0 |
2964553 | 97987 | None | BOQ189 | Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments-1.5 Sqmm.( Lighting & Power Circuit Earthing) - | Mtr | 26.0 | 26.0 | 2400.0 | False | None | None | False | None | False | 62400.0 | 0 |
2964554 | 97987 | None | BOQ190 | Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments- 2.5 Sqmm.( Lighting & 15A Power Circuit Phase & Neutral + AC Circuit and Geyser earthing) | Mtr | 42.0 | 42.0 | 3600.0 | False | None | None | False | None | False | 151200.0 | 0 |
2964555 | 97987 | None | BOQ191 | Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments-4 Sqmm.( AC and Geyser Phase & Neutral) | Mtr | 63.0 | 63.0 | 1600.0 | False | None | None | False | None | False | 100800.0 | 0 |
2964556 | 97987 | None | BOQ192 | Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments-6 Sqmm.( Earthing from Metering panel to TPN DB ) | Mtr | 92.0 | 92.0 | 400.0 | False | None | None | False | None | False | 36800.0 | 0 |
2964557 | 97987 | None | BOQ193 | Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments- 10Sqmm.( For Main Incomer from Metering Panel to TPN DB) | Mtr | 167.0 | 167.0 | 640.0 | False | None | None | False | None | False | 106880.0 | 0 |
2964558 | 97987 | None | BOQ194 | Supplying and fixing of.4' feet - PVC Batten with integrated LED tube 20/22.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80.Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.-4 feet LED Fitting. | Each | 690.0 | 690.0 | 102.0 | False | None | None | False | None | False | 70380.0 | 0 |
2964559 | 97987 | None | BOQ195 | Supplying and fixing of.2' feet - PVC Batten with integrated LED tube 9/10.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80.Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.-2 feet LED Fitting-Mirror lighting fitting. | Each | 551.0 | 551.0 | 16.0 | False | None | None | False | None | False | 8816.0 | 0 |
2964560 | 97987 | None | BOQ196 | Supplying & fixing of retrofit type - LED bulb.12W,65000k with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%.efficacy greater than80 lumen per W, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( Cost including with necessary base fixing pedent type holder.) | Each | 269.0 | 269.0 | 80.0 | False | None | None | False | None | False | 21520.0 | 0 |
2964561 | 97987 | None | BOQ197 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding.Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty.(BLDC fans) | Each | 2677.0 | 2677.0 | 48.0 | False | None | None | False | None | False | 128496.0 | 0 |
2964562 | 97987 | None | BOQ198 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A.ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 315.0 | 315.0 | 48.0 | False | None | None | False | None | False | 15120.0 | 0 |
2964563 | 97987 | None | BOQ199 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300mm) | Each | 2969.0 | 2969.0 | 24.0 | False | None | None | False | None | False | 71256.0 | 0 |
2964564 | 97987 | None | BOQ200 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 707.0 | 707.0 | 24.0 | False | None | None | False | None | False | 16968.0 | 0 |
2964565 | 97987 | None | BOQ201 | Supplying and fixing of round or oblong type bulk head fitting with glass cover and 12/15 watts LED lamp | Each | 900.0 | 900.0 | 12.0 | False | None | None | False | None | False | 10800.0 | 0 |
2964566 | 97987 | None | BOQ202 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. | Each | 971.0 | 971.0 | 16.0 | False | None | None | False | None | False | 15536.0 | 0 |
2964567 | 97987 | None | BOQ203 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.- 6-32A DP | Each | 739.0 | 739.0 | 16.0 | False | None | None | False | None | False | 11824.0 | 0 |
2964568 | 97987 | None | BOQ204 | Supplying and fixing regular MCB distribution boards on wall/Wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.- 6 WAY TP & N Double Door DB. | Each | 4940.0 | 4940.0 | 9.0 | False | None | None | False | None | False | 44460.0 | 0 |
2964569 | 97987 | None | BOQ205 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board.( 63A 4 pole ). | Each | 5545.0 | 5545.0 | 9.0 | False | None | None | False | None | False | 49905.0 | 0 |
2964570 | 97987 | None | BOQ206 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC. | Each | 3088.0 | 3088.0 | 9.0 | False | None | None | False | None | False | 27792.0 | 0 |
2964571 | 97987 | None | BOQ207 | Providing 6-32 Amps Single pole MCB for Outgoing Circuits.(25A-2nos for AC + 20A - 2nos for Geyser + 16A -5nos for 15A power socket + 6A-10A -9 nos for lighting circuit.) | Each | 415.0 | 415.0 | 162.0 | False | None | None | False | None | False | 67230.0 | 0 |
2964572 | 97987 | None | BOQ208 | Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility 600mm x 600mm x 170mm | Each | 14520.0 | 14520.0 | 9.0 | False | None | None | False | None | False | 130680.0 | 0 |
2964573 | 97987 | None | BOQ209 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C.50 Hz 12/24v D.C. | Each | 515.0 | 515.0 | 27.0 | False | None | None | False | None | False | 13905.0 | 0 |
2964574 | 97987 | None | BOQ210 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter. | Each | 5705.0 | 5705.0 | 9.0 | False | None | None | False | None | False | 51345.0 | 0 |
2964575 | 97987 | None | BOQ211 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.-63A | Each | 401.0 | 401.0 | 27.0 | False | None | None | False | None | False | 10827.0 | 0 |
2964576 | 97987 | None | BOQ212 | Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses).With AC-23A duty and as per IS- 13947.- 63A | Each | 2312.0 | 2312.0 | 9.0 | False | None | None | False | None | False | 20808.0 | 0 |
2964577 | 97987 | None | BOQ213 | Supplying and fixing HRC fuse units base on existing switch / panel board. | Each | 612.0 | 612.0 | 27.0 | False | None | None | False | None | False | 16524.0 | 0 |
2964578 | 97987 | None | BOQ214 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 M long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3.of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia. | Each | 3510.0 | 3510.0 | 18.0 | False | None | None | False | None | False | 63180.0 | 0 |
2964579 | 97987 | None | BOQ215 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.-25x3mm GI strip. | Mtr | 82.0 | 82.0 | 270.0 | False | None | None | False | None | False | 22140.0 | 0 |
2964580 | 97987 | None | BOQ216 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.8 SWG GI Wire. | Mtr | 60.0 | 60.0 | 225.0 | False | None | None | False | None | False | 13500.0 | 0 |
2964581 | 97987 | None | BOQ217 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.- 35 Sqmm | Each | 50.0 | 50.0 | 72.0 | False | None | None | False | None | False | 3600.0 | 0 |
2964582 | 97987 | None | BOQ218 | Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.- 50 Sqmm | Each | 80.0 | 80.0 | 8.0 | False | None | None | False | None | False | 640.0 | 0 |
2964583 | 97987 | None | BOQ219 | Supplying and fixing of DANGER, NO-ADMISSION & NO SMOKING board made out of MS sheet metal with two coats of non corrosive enameled paint | Each | 110.0 | 110.0 | 18.0 | False | None | None | False | None | False | 1980.0 | 0 |
2964584 | 97987 | None | BOQ220 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.- 40mm | Mtr | 450.0 | 450.0 | 15.0 | False | None | None | False | None | False | 6750.0 | 0 |
2964585 | 97987 | None | BOQ221 | EB Incomer Cable -3.5C X 70 sq.mm XLPE Ar.Al.Cable Supply and Laying ( Cable QTY Approxmate only ) | Mtr | 450.0 | 450.0 | 100.0 | False | None | None | False | None | False | 45000.0 | 0 |
2964586 | 97987 | None | BOQ222 | Supply and End termination of Above Cable Gland with 70sq.mm including required Alumminum Suitable legs and tape etc | Each | 1200.0 | 1200.0 | 2.0 | False | None | None | False | None | False | 2400.0 | 0 |
2964587 | 97987 | None | BOQ223 | EB Incomer Cable -3.5C X 25 sq.mm XLPE Ar.Al.Cable Supply and Laying ( Cable QTY Approxmate only ) | Mtr | 350.0 | 350.0 | 225.0 | False | None | None | False | None | False | 78750.0 | 0 |
2964588 | 97987 | None | BOQ224 | Supply and End termination of Above Cable Gland with 25 sq.mm including required Alumminum Suitable legs and tape etc | Each | 800.0 | 800.0 | 26.0 | False | None | None | False | None | False | 20800.0 | 0 |