createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709805338344
version7
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd580000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-04-2024 16:00:00
tenderQueryClose02-04-2024 16:00:00
technicalBidOpen12-04-2024 16:05:00
publishedDate11-03-2024 11:32:15
publishedByPostBESCOM_GM_CIV_BNG
publishedByUserKPE16137 - T G RAMAKRISHNA
bidValidityPeriod120
noOfCalls1
preBidMeetingDate21-03-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonT G Ramakrishna
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8277892569
tenderSupplierListNone
tenderSchedule
createdTs1709805338382
version13
createdDateNone
modifiedDateNone
tenderNumberBESCOM/2023-24/BD/WORK_INDENT152
titleConstruction of W6 sub division office, O&M office, service station in the vacant land of Byatarayanapura division office premises and modification of the exisisting W6 sub division for accomodating MPD Division office and other allied works
descriptionConstruction of W6 sub division office, O&M office, service station in the vacant land of Byatarayanapura division office premises and modification of the exisisting W6 sub division for accomodating MPD Division office and other allied works
categoryWORKS
categoryTextWorks
ecv38632660.99
deptNameBangalore Electricity Supply Company Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3834
locationNameBESCOM Corporate Office Civil Section Bengaluru
provisionalAmount40000000.0
groupOverheadTotal5893117.78
fileNumberBESCOM/GM/Civil/2023-24/42
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17098053380001NoneNoneBuildingsConstruction of W6 sub division office, O&M office, service station in the vacant land of Byatarayanapura division office premises and modification of the exisisting W6 sub division for accomodating MPD Division office and other allied works32739543.21
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
295686297747NoneBOQ01Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer in charge.Cum1829.31829.325.0FalseNoneNoneFalseNoneFalse45732.50
295686397747NoneBOQ02Demolishing R.C.C.work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in charge.Ground floorCum2668.62668.63.0FalseNoneNoneFalseNoneFalse8005.80
295686497747NoneBOQ03Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in charge.Cum530.2530.27.0FalseNoneNoneFalseNoneFalse3711.40
295686597747NoneBOQ04Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer in charge to the appropriate disposal area.Cum400.4400.4250.0FalseNoneNoneFalseNoneFalse100100.00
295686697747NoneBOQ05Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Manual Means In area of light jungle100 Sqm1234.21234.24.0FalseNoneNoneFalseNoneFalse4936.80
295686797747NoneBOQ06Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum100.1100.125.0FalseNoneNoneFalseNoneFalse2502.50
295686897747NoneBOQ07Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 mCum266.2266.2324.0FalseNoneNoneFalseNoneFalse86248.80
295686997747NoneBOQ08Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work.Depth exceeding 1.5m, but not exceeding 3 mCum284.9284.951.0FalseNoneNoneFalseNoneFalse14529.90
295687097747NoneBOQ09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc.in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum292.6292.6150.0FalseNoneNoneFalseNoneFalse43890.00
295687197747NoneBOQ10Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum521.4521.4100.0FalseNoneNoneFalseNoneFalse52140.00
295687297747NoneBOQ11Providing and Filling in foundation with granite / trap broken metal 100mm.And down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.Cum2950.22950.226.0FalseNoneNoneFalseNoneFalse76705.20
295687397747NoneBOQ12Providing and injecting chemical emulsion for Pre constructional Anti Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C./ Lindane 20percentage E.C.@ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm129.8129.8399.47FalseNoneNoneFalseNoneFalse51851.2060
295687497747NoneBOQ13Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum6230.416230.4133.18FalseNoneNoneFalseNoneFalse206725.00380
295687597747NoneBOQ14Providing and laying in position Cement Concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6838.716838.7136.32FalseNoneNoneFalseNoneFalse248381.94720
295687697747NoneBOQ15Terrace FloorCum7043.877043.8729.96FalseNoneNoneFalseNoneFalse211034.34520
295687797747NoneBOQ16Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc.The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6955.316955.3112.51FalseNoneNoneFalseNoneFalse87010.92810
295687897747NoneBOQ17Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6969.616969.61117.54FalseNoneNoneFalseNoneFalse819207.95940
295687997747NoneBOQ18Additionalities for form work for Isolated Footing @ 8percentageCum557.57557.5737.57FalseNoneNoneFalseNoneFalse20947.90490
295688097747NoneBOQ19Additionalities for form work for columns & walls upto plinth beam @ 70percentageCum4878.724878.7236.31FalseNoneNoneFalseNoneFalse177146.32320
295688197747NoneBOQ20Additionalities for form work for plinth beam @ 50percentageCum3484.813484.8110.58FalseNoneNoneFalseNoneFalse36869.28980
295688297747NoneBOQ21Additionalities for form work for slab @ 50percentageCum3484.813484.813.86FalseNoneNoneFalseNoneFalse13451.36660
295688397747NoneBOQ22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) Sqm0 Design Mix Using 25 mm nominal size graded crushed coarse aggregatesCum7527.317527.3178.45FalseNoneNoneFalseNoneFalse590517.46950
295688497747NoneBOQ23b) First FloorCum7602.587602.5887.84FalseNoneNoneFalseNoneFalse667810.62720
295688597747NoneBOQ24c) Second FloorCum7677.857677.8561.54FalseNoneNoneFalseNoneFalse472494.8890
295688697747NoneBOQ25c) Terrace FloorCum7753.127753.123.95FalseNoneNoneFalseNoneFalse30624.8240
295688797747NoneBOQ26Additionalities for form work for columns @ 70percentage Ground floorCum5269.125269.125.44FalseNoneNoneFalseNoneFalse28664.01280
295688897747NoneBOQ27Additionalities for form work for columns @ 70percentage First floorCum5321.85321.85.44FalseNoneNoneFalseNoneFalse28950.5920
295688997747NoneBOQ28Additionalities for form work for columns @ 70percentage c) Second FloorCum5374.495374.495.44FalseNoneNoneFalseNoneFalse29237.22560
295689097747NoneBOQ29Additionalities for form work for columns @ 70percentage c) Terrace FloorCum5427.195427.191.32FalseNoneNoneFalseNoneFalse7163.89080
295689197747NoneBOQ30Additionalities for form work for Roof beam, Lintel beam @ 60percentage Ground floorCum4516.394516.3917.3FalseNoneNoneFalseNoneFalse78133.5470
295689297747NoneBOQ31Additionalities for form work for Roof beam, Lintel beam @ 60percentage First floorCum4561.554561.5527.45FalseNoneNoneFalseNoneFalse125214.54750
295689397747NoneBOQ32Additionalities for form work for Roof beam, Lintel beam @ 60percentage c) Second FloorCum4606.74606.718.47FalseNoneNoneFalseNoneFalse85085.7490
295689497747NoneBOQ33Additionalities for form work for Roof beam, Lintel beam @ 60percentage d) Terrace FloorCum4651.874651.870.59FalseNoneNoneFalseNoneFalse2744.60330
295689597747NoneBOQ34Additionalities for form work for Roof slab @ 50percentage Ground floorCum3763.653763.6549.27FalseNoneNoneFalseNoneFalse185435.03550
295689697747NoneBOQ35Additionalities for form work for Roof slab @ 50percentage First floorCum3801.283801.2849.27FalseNoneNoneFalseNoneFalse187289.06560
295689797747NoneBOQ36Additionalities for form work for Roof slab @ 50percentage c) Second FloorCum3838.923838.9232.29FalseNoneNoneFalseNoneFalse123958.72680
295689897747NoneBOQ37Additionalities for form work for Roof slab @ 50percentage c) Terrace FloorCum3876.553876.552.15FalseNoneNoneFalseNoneFalse8334.58250
295689997747NoneBOQ38Additionalities for form work for Chajja @ 45percentage Ground floorCum3387.283387.282.718FalseNoneNoneFalseNoneFalse9206.627040
295690097747NoneBOQ39Additionalities for form work for Chajja @ 45percentage First floorCum3421.153421.151.973FalseNoneNoneFalseNoneFalse6749.928950
295690197747NoneBOQ40Additionalities for form work for Chajja @ 45percentage Second floorCum3455.033455.031.62FalseNoneNoneFalseNoneFalse5597.14860
295690297747NoneBOQ41Additionalities for form work for Chajja @ 45percentage Terrace floorCum3488.93488.92.16FalseNoneNoneFalseNoneFalse7536.0240
295690397747NoneBOQ42Additionalities for form work for Staircase @ 45percentage Ground floorCum3387.283387.283.73FalseNoneNoneFalseNoneFalse12634.55440
295690497747NoneBOQ43Additionalities for form work for Staircase @ 45percentage First floorCum3421.153421.153.74FalseNoneNoneFalseNoneFalse12795.1010
295690597747NoneBOQ44Additionalities for form work for Staircase @ 45percentage Second floorCum3455.033455.033.73FalseNoneNoneFalseNoneFalse12887.26190
295690697747NoneBOQ45Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Ground floorTonne98402.798402.720.63FalseNoneNoneFalseNoneFalse2030047.7010
295690797747NoneBOQ46b) First FloorTonne99386.7399386.7312.61FalseNoneNoneFalseNoneFalse1253266.66530
295690897747NoneBOQ47c) Second FloorTonne100370.75100370.759.09FalseNoneNoneFalseNoneFalse912370.11750
295690997747NoneBOQ48d)Terrace FloorTonne101354.78101354.780.72FalseNoneNoneFalseNoneFalse72975.44160
295691097747NoneBOQ49Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7027.97027.918.0FalseNoneNoneFalseNoneFalse126502.20
295691197747NoneBOQ50Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer in charge.Sqm280.5280.5120.0FalseNoneNoneFalseNoneFalse33660.00
295691297747NoneBOQ51Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.a) Ground floorSqm1441.01441.0418.0FalseNoneNoneFalseNoneFalse602338.00
295691397747NoneBOQ52b) First floorSqm1455.41455.4252.0FalseNoneNoneFalseNoneFalse366760.80
295691497747NoneBOQ53c) Second FloorSqm1469.821469.82104.0FalseNoneNoneFalseNoneFalse152861.280
295691597747NoneBOQ54d)Terrace FloorSqm1484.231484.2339.0FalseNoneNoneFalseNoneFalse57884.970
295691697747NoneBOQ55Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.a) Ground floorSqm1214.41214.488.0FalseNoneNoneFalseNoneFalse106867.20
295691797747NoneBOQ56b) First floorSqm1226.541226.5451.0FalseNoneNoneFalseNoneFalse62553.540
295691897747NoneBOQ57c) Second FloorSqm1238.681238.6837.0FalseNoneNoneFalseNoneFalse45831.160
295691997747NoneBOQ58Providing and fixing in position Fixed 12mm toughened glass as fixed glass from Floor to available Ceiling level for Partitions.The work includes cost of all materials, approved hardware, fixing the same as per site c onditions to a neat finished work as per drawings and directions etc., complete.MRMtr4800.04800.0100.0FalseNoneNoneFalseNoneFalse480000.00
295692097747NoneBOQ59b) First floorMtr4800.04800.023.0FalseNoneNoneFalseNoneFalse110400.00
295692197747NoneBOQ60c) Second FloorMtr4800.04800.059.0FalseNoneNoneFalseNoneFalse283200.00
295692297747NoneBOQ61Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc.for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc.to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.200mm length Make: Saint Gobain Series SGG ET 725 SGU/ EquivalentSqm5194.25194.222.3FalseNoneNoneFalseNoneFalse115830.660
295692397747NoneBOQ62b) First floorSqm5246.145246.1410.5FalseNoneNoneFalseNoneFalse55084.470
295692497747NoneBOQ63c) Second FloorSqm5298.085298.0821.7FalseNoneNoneFalseNoneFalse114968.3360
295692597747NoneBOQ64Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc.complete as per direction of Engineer incharge.200mm lengthNos1650.01650.020.0FalseNoneNoneFalseNoneFalse33000.00
295692697747NoneBOQ65b) First floorNos1666.51666.510.0FalseNoneNoneFalseNoneFalse16665.00
295692797747NoneBOQ66c) Second FloorNos1683.01683.022.0FalseNoneNoneFalseNoneFalse37026.00
295692897747NoneBOQ67Glass door locksMRNos1500.01500.010.0FalseNoneNoneFalseNoneFalse15000.00
295692997747NoneBOQ68b) First floorNos1500.01500.05.0FalseNoneNoneFalseNoneFalse7500.00
295693097747NoneBOQ69c) Second FloorNos1500.01500.011.0FalseNoneNoneFalseNoneFalse16500.00
295693197747NoneBOQ70Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58 60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer InCharge.(Fixtures shall be paid for separately) Size 62 x 100mmMtr772.2772.250.6FalseNoneNoneFalseNoneFalse39073.320
295693297747NoneBOQ71b) First floorMtr779.92779.9226.0FalseNoneNoneFalseNoneFalse20277.920
295693397747NoneBOQ72c) Second FloorMtr787.64787.6457.6FalseNoneNoneFalseNoneFalse45368.0640
295693497747NoneBOQ73Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58 60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thicknessSqm4445.14445.10.9FalseNoneNoneFalseNoneFalse4000.590
295693597747NoneBOQ74b) First floorSqm4489.554489.550.5FalseNoneNoneFalseNoneFalse2244.7750
295693697747NoneBOQ75c) Second FloorSqm4534.04534.01.0FalseNoneNoneFalseNoneFalse4534.00
295693797747NoneBOQ76Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.completeNos143.0143.020.0FalseNoneNoneFalseNoneFalse2860.00
295693897747NoneBOQ77b) First floorNos144.43144.4310.0FalseNoneNoneFalseNoneFalse1444.30
295693997747NoneBOQ78c) Second FloorNos145.85145.8522.0FalseNoneNoneFalseNoneFalse3208.70
295694097747NoneBOQ79Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc.completeNos260.7260.720.0FalseNoneNoneFalseNoneFalse5214.00
295694197747NoneBOQ80b) First floorNos263.3263.310.0FalseNoneNoneFalseNoneFalse2633.00
295694297747NoneBOQ81c) Second FloorNos265.91265.9122.0FalseNoneNoneFalseNoneFalse5850.020
295694397747NoneBOQ82Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats, square or round bars etc.including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc.a) Ground floorKg201.3201.3911.0FalseNoneNoneFalseNoneFalse183384.30
295694497747NoneBOQ83b) First floorKg203.31203.31649.0FalseNoneNoneFalseNoneFalse131948.190
295694597747NoneBOQ84c) Second FloorKg205.32205.32681.0FalseNoneNoneFalseNoneFalse139822.920
295694697747NoneBOQ85d)Terrace FloorKg207.33207.3338.0FalseNoneNoneFalseNoneFalse7878.540
295694797747NoneBOQ86Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame.The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm.Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm.Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock.Wall thickness of frame & sash shall be of 2mm 2.5mm.Maximum possible size 2419mm x 2200mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) a) Ground floorSqm7407.47407.444.0FalseNoneNoneFalseNoneFalse325925.60
295694897747NoneBOQ87b) First floorSqm7481.477481.4739.0FalseNoneNoneFalseNoneFalse291777.330
295694997747NoneBOQ88c) Second FloorSqm7555.547555.5433.0FalseNoneNoneFalseNoneFalse249332.820
295695097747NoneBOQ89d)Terrace FloorSqm7629.627629.622.0FalseNoneNoneFalseNoneFalse15259.240
295695197747NoneBOQ90Supplying and fixing rolling shutters of approved make, made of required size M.S.laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 part 1 and M.S.top cover of required thickness for rolling shutters.80x0.90 mm M.S.laths with 0.90 mm thick top coverSqm2502.52502.527.0FalseNoneNoneFalseNoneFalse67567.50
295695297747NoneBOQ91Providing and fixing ball bearing for rolling shutters including cost of materials, labour, usage charges of machinery completeNos443.3443.312.0FalseNoneNoneFalseNoneFalse5319.60
295695397747NoneBOQ92Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Kg621.5621.5220.0FalseNoneNoneFalseNoneFalse136730.00
295695497747NoneBOQ93b) First floorKg627.71627.71220.0FalseNoneNoneFalseNoneFalse138096.20
295695597747NoneBOQ94c) Second FloorKg633.93633.93220.0FalseNoneNoneFalseNoneFalse139464.60
295695697747NoneBOQ95Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Kg161.7161.7500.0FalseNoneNoneFalseNoneFalse80850.00
295695797747NoneBOQ96Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Kg149.6149.61000.0FalseNoneNoneFalseNoneFalse149600.00
295695897747NoneBOQ97Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in Charge.Sqm9103.69103.612.0FalseNoneNoneFalseNoneFalse109243.20
295695997747NoneBOQ98Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum151881.4151881.40.2FalseNoneNoneFalseNoneFalse30376.280
295696097747NoneBOQ99b) First floorCum153400.21153400.210.1FalseNoneNoneFalseNoneFalse15340.0210
295696197747NoneBOQ100c) Second FloorCum154919.02154919.020.1FalseNoneNoneFalseNoneFalse15491.9020
295696297747NoneBOQ101Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm.thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications.(excluding cost of fixtures).Sqm8331.48331.47.6FalseNoneNoneFalseNoneFalse63318.640
295696397747NoneBOQ102b) First floorSqm8414.718414.712.1FalseNoneNoneFalseNoneFalse17670.8910
295696497747NoneBOQ103c) Second FloorSqm8498.028498.022.9FalseNoneNoneFalseNoneFalse24644.2580
295696597747NoneBOQ104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications.Nos1117.61117.62.0FalseNoneNoneFalseNoneFalse2235.20
295696697747NoneBOQ105b) First floorNos1128.771128.771.0FalseNoneNoneFalseNoneFalse1128.770
295696797747NoneBOQ106c) Second FloorNos1139.951139.951.0FalseNoneNoneFalseNoneFalse1139.950
295696897747NoneBOQ107Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete.Nos1157.21157.22.0FalseNoneNoneFalseNoneFalse2314.40
295696997747NoneBOQ108b) First floorNos1168.771168.771.0FalseNoneNoneFalseNoneFalse1168.770
295697097747NoneBOQ109c) Second FloorNos1180.341180.341.0FalseNoneNoneFalseNoneFalse1180.340
295697197747NoneBOQ110Providing and fixing bright finished brass handles with screws etc.complete: Brass handles 125 mm with plate 175x32 mmEach273.9273.94.0FalseNoneNoneFalseNoneFalse1095.60
295697297747NoneBOQ111b) First floorEach276.63276.632.0FalseNoneNoneFalseNoneFalse553.260
295697397747NoneBOQ112c) Second FloorEach279.37279.372.0FalseNoneNoneFalseNoneFalse558.740
295697497747NoneBOQ113Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 250x10mmNos220.0220.04.0FalseNoneNoneFalseNoneFalse880.00
295697597747NoneBOQ114b) First floorNos222.2222.22.0FalseNoneNoneFalseNoneFalse444.40
295697697747NoneBOQ115c) Second FloorNos224.4224.42.0FalseNoneNoneFalseNoneFalse448.80
295697797747NoneBOQ116Providing and fixing PTMT door catcher of length 72 mm and dia.of 42 mm with suitable washers weighing not less than 33 gmsNos60.560.54.0FalseNoneNoneFalseNoneFalse242.00
295697897747NoneBOQ117b) First floorNos61.161.12.0FalseNoneNoneFalseNoneFalse122.20
295697997747NoneBOQ118c) Second FloorNos61.7161.712.0FalseNoneNoneFalseNoneFalse123.420
295698097747NoneBOQ119Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1.The surface to be polished is rubbed with sand paper 80/120 Nosand then with sand paper of 160/180 nos.2.Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc.Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4.On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion.This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs.The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer in Charge.(Final coat to be done in 1 or 2 layers without gap of time.)Sqm744.7744.77.6FalseNoneNoneFalseNoneFalse5659.720
295698197747NoneBOQ120b) First floorSqm752.14752.142.1FalseNoneNoneFalseNoneFalse1579.4940
295698297747NoneBOQ121c) Second FloorSqm759.59759.592.9FalseNoneNoneFalseNoneFalse2202.8110
295698397747NoneBOQ122Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6 Kg/Sqm to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/Sqm and protection with 120gsm Geo textile over the waterproofing membrane.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm925.66925.66348.4FalseNoneNoneFalseNoneFalse322499.9440
295698497747NoneBOQ123Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per Sqm,having tensile strength greater than 1.5N/mSqm, elongation greater than 300percentage with solid content not less than 60percentage in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/Sqm, and spreading 60 gsm geotextile between two top coats completely as per specification.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm810.7810.756.48FalseNoneNoneFalseNoneFalse45788.3360
295698597747NoneBOQ124Providing and laying Polished Glazed Vitrified tiles with thickness 10 mm in floor with different sizes with water absorption less than 0.08percentage and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately)..Size of Tile 600x1200 mmSqm2189.02189.0182.0FalseNoneNoneFalseNoneFalse398398.00
295698697747NoneBOQ125b) First floorSqm2210.892210.89243.0FalseNoneNoneFalseNoneFalse537246.270
295698797747NoneBOQ126c) Second FloorSqm2232.772232.77274.0FalseNoneNoneFalseNoneFalse611778.980
295698897747NoneBOQ127Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percentage and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1259.51259.524.0FalseNoneNoneFalseNoneFalse30228.00
295698997747NoneBOQ128b) First floorSqm1272.091272.0917.0FalseNoneNoneFalseNoneFalse21625.530
295699097747NoneBOQ129c) Second FloorSqm1284.691284.6917.0FalseNoneNoneFalseNoneFalse21839.730
295699197747NoneBOQ130Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge. .d) Terrace FloorSqm1591.861591.86111.0FalseNoneNoneFalseNoneFalse176696.460
295699297747NoneBOQ131Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 Kg of organic coated filler of desired shade (0.10 Kg of hardener and 0.20 Kg of resin per Kg), including filling / grouting and finishing complete as per direction of Engineer in charge.Sqm229.9229.9627.0FalseNoneNoneFalseNoneFalse144147.30
295699397747NoneBOQ132Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc.all complete as specified and as directed by the Engineer in Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3137.23137.286.02FalseNoneNoneFalseNoneFalse269861.9440
295699497747NoneBOQ133b) First floorMtr3168.573168.5786.02FalseNoneNoneFalseNoneFalse272560.39140
295699597747NoneBOQ134c) Second FloorMtr3199.943199.9486.02FalseNoneNoneFalseNoneFalse275258.83880
295699697747NoneBOQ135Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1593.91593.9106.0FalseNoneNoneFalseNoneFalse168953.40
295699797747NoneBOQ136b) First floorSqm1609.831609.83106.0FalseNoneNoneFalseNoneFalse170641.980
295699897747NoneBOQ137c) Second FloorSqm1625.771625.77106.0FalseNoneNoneFalseNoneFalse172331.620
295699997747NoneBOQ138Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer in charge.Mtr360.8360.85.0FalseNoneNoneFalseNoneFalse1804.00
295700097747NoneBOQ139Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M 30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc.all complete as per the direction of Engineer in charge.Sqm880.0880.0168.0FalseNoneNoneFalseNoneFalse147840.00
295700197747NoneBOQ140Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. Internal wall plastering.Sqm306.9306.91063.0FalseNoneNoneFalseNoneFalse326234.70
295700297747NoneBOQ141b) First floorSqm309.96309.96650.0FalseNoneNoneFalseNoneFalse201474.00
295700397747NoneBOQ142c) Second FloorSqm313.03313.03307.0FalseNoneNoneFalseNoneFalse96100.210
295700497747NoneBOQ143d)Terrace FloorSqm316.1316.159.0FalseNoneNoneFalseNoneFalse18649.90
295700597747NoneBOQ144Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge.Rough plastering.Sqm383.9383.9247.0FalseNoneNoneFalseNoneFalse94823.30
295700697747NoneBOQ145b) First floorSqm387.73387.73142.0FalseNoneNoneFalseNoneFalse55057.660
295700797747NoneBOQ146c) Second FloorSqm391.57391.57142.0FalseNoneNoneFalseNoneFalse55602.940
295700897747NoneBOQ147Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. Ceiling Plastering.Sqm355.3355.3324.0FalseNoneNoneFalseNoneFalse115117.20
295700997747NoneBOQ148b) First floorSqm358.85358.85324.0FalseNoneNoneFalseNoneFalse116267.40
295701097747NoneBOQ149c) Second FloorSqm362.4362.4324.0FalseNoneNoneFalseNoneFalse117417.60
295701197747NoneBOQ150d)Terrace FloorSqm365.95365.9515.0FalseNoneNoneFalseNoneFalse5489.250
295701297747NoneBOQ151Providing and fixing Jute mat on ceiling soffit during roof slab concrte to create a rough surface for ceiling plastering MRSqm35.035.0987.0FalseNoneNoneFalseNoneFalse34545.00
295701397747NoneBOQ152Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. External PlasteringSqm423.5423.5260.0FalseNoneNoneFalseNoneFalse110110.00
295701497747NoneBOQ153b) First floorSqm427.73427.73260.0FalseNoneNoneFalseNoneFalse111209.80
295701597747NoneBOQ154c) Second FloorSqm431.96431.96260.0FalseNoneNoneFalseNoneFalse112309.60
295701697747NoneBOQ155Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer in Charge.Sqm63.863.8260.0FalseNoneNoneFalseNoneFalse16588.00
295701797747NoneBOQ156b) First floorSqm64.4364.43260.0FalseNoneNoneFalseNoneFalse16751.80
295701897747NoneBOQ157c) Second FloorSqm65.0765.07260.0FalseNoneNoneFalseNoneFalse16918.20
295701997747NoneBOQ158Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications.( length of mesh only be measured for payment. Plaster mesh 100mm wideMtr48.448.4600.0FalseNoneNoneFalseNoneFalse29040.00
295702097747NoneBOQ159b) First floorMtr48.8848.88600.0FalseNoneNoneFalseNoneFalse29328.00
295702197747NoneBOQ160c) Second FloorMtr49.3649.36600.0FalseNoneNoneFalseNoneFalse29616.00
295702297747NoneBOQ161d)Terrace FloorMtr49.8549.85140.0FalseNoneNoneFalseNoneFalse6979.00
295702397747NoneBOQ162Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Mtr110.0110.01387.0FalseNoneNoneFalseNoneFalse152570.00
295702497747NoneBOQ163b) First floorMtr111.1111.11387.0FalseNoneNoneFalseNoneFalse154095.70
295702597747NoneBOQ164c) Second FloorMtr112.2112.2324.0FalseNoneNoneFalseNoneFalse36352.80
295702697747NoneBOQ165d)Terrace FloorMtr113.3113.366.0FalseNoneNoneFalseNoneFalse7477.80
295702797747NoneBOQ166Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.Sqm58.358.31387.0FalseNoneNoneFalseNoneFalse80862.10
295702897747NoneBOQ167b) First floorSqm58.8858.881387.0FalseNoneNoneFalseNoneFalse81666.560
295702997747NoneBOQ168c) Second FloorSqm59.4659.46324.0FalseNoneNoneFalseNoneFalse19265.040
295703097747NoneBOQ169d)Terrace FloorSqm60.0460.0466.0FalseNoneNoneFalseNoneFalse3962.640
295703197747NoneBOQ170Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats as per specifications and as per directions of Engineer in charge.Sqm121.0121.01387.0FalseNoneNoneFalseNoneFalse167827.00
295703297747NoneBOQ171b) First floorSqm122.21122.211387.0FalseNoneNoneFalseNoneFalse169505.270
295703397747NoneBOQ172c) Second FloorSqm123.42123.421387.0FalseNoneNoneFalseNoneFalse171183.540
295703497747NoneBOQ173d)Terrace FloorSqm124.63124.6359.0FalseNoneNoneFalseNoneFalse7353.170
295703597747NoneBOQ174Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 meter square over and including priming coat of exterior primer applied @ 2.20 Kg/10 meter square) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm191.4191.4260.0FalseNoneNoneFalseNoneFalse49764.00
295703697747NoneBOQ175b) First floorSqm193.31193.31260.0FalseNoneNoneFalseNoneFalse50260.60
295703797747NoneBOQ176c) Second FloorSqm195.22195.22260.0FalseNoneNoneFalseNoneFalse50757.20
295703897747NoneBOQ177d)Terrace FloorSqm197.14197.14125.0FalseNoneNoneFalseNoneFalse24642.50
295703997747NoneBOQ178Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.Sqm183.7183.7150.0FalseNoneNoneFalseNoneFalse27555.00
295704097747NoneBOQ179Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically sealed 6 12 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer in Charge.The IGUs shall be assembled in the factory/workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item Nos18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percentage, Light reflection internal 10 to 15percentage, light reflection external 10 to 20 percentage, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W/Sqm degree K etc.The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.Sqm3347.33347.320.0FalseNoneNoneFalseNoneFalse66946.00
295704197747NoneBOQ180Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part III).The Suspended System held with Spider Fittings of SS 316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick.The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi metallic contacts, all complete to perform as per specification and approved drawings.The complete system to be designed to accommodate hermal expansion & seismic movements etc.The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc.all complete.For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.Sqm8747.28747.29.0FalseNoneNoneFalseNoneFalse78724.80
295704297747NoneBOQ181Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the ventilator frame.The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6290.96290.922.0FalseNoneNoneFalseNoneFalse138399.80
295704397747NoneBOQ182Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc.,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge.For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percentage, Light reflection internal 10 to 15percentage, light reflection external 10 to 20 percentage, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W/Sqm K etc..The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.Sqm2178.02178.04.0FalseNoneNoneFalseNoneFalse8712.00
295704497747NoneBOQ183Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent.The panel should consist of 3mm thick non halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119 12 and clause B, S1, do as per ENT 13501 1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm.The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint.The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight portionSqm4387.94387.914.0FalseNoneNoneFalseNoneFalse61430.60
295704597747NoneBOQ184Providing, fabricating and fixing of 6 mm thick High Pressure Laminate sheets in standard size of 1200 mm x 2400 mm (Sheets can be supplied in customized length depending on requirement).Sheets shall be manufactured involving a series of mechanical process in a state of the art facility shall comprise of 0.25 mm Aluminium skins on both sides sandwiching an LDPE (Low Density Poly Ethylene) core having a density of 0.92 g/cCum giving the overall weight of HPL at 7.8 Kg/Sqm.Aluminium skins to have a desired lacquer in Lumiflon coated on one side/Both side.The supplied panels shall have a dexterity to be formed in convex and concave shapes as also the ability to bend in 90 degrees under a mechanical process.Panel will be installed on Aluminium tubes at 500 mm c/c distance with special L brackets.There will be special fixing treatment on all the corner sections.Aluminium tube size will be 25 mm x 50 mm.Boards will be fixed on the Aluminium channels with colour matched rivets/ MS polymer Adhesives and brackets through 8 mm drill hole in boards and 5 mm dia drill holes in aluminium box.Rivets will be installed by automatic rivet guns / adhesive should be used with proper silicone extrusion gun and properly laid over panel and aluminium tube on every 500mm gap as per direction of Engineer in charge.Wooden textured Colored sheets Single sidedSqm3434.23434.232.0FalseNoneNoneFalseNoneFalse109894.40
295704697747NoneBOQ185Providing and fabricating lacquered glass formed using Aluminium frame work at 600mm c/c.The frame work shall be clad with 8mm thick lacquered glass with 12mm thick MDF /ply backing, complete as per detailed drawing and instructions of the Architect.MRSqm7500.07500.016.0FalseNoneNoneFalseNoneFalse120000.00
295704797747NoneBOQ186Providing & fixing veneer panelling, over the 50mm x 35mm sal wood frame work at spacing not exceeding 600mm c/c fixed to the wall and top covered out of 4mm thick approved quality veneer, fixed over 12mm thick ply of approved brand, termite and water resitantfinished with melaminepolish, complete includingcost and conveyance of all materials, labour for all items of work HOM etc., complete as per specificationSqm4112.94112.9135.0FalseNoneNoneFalseNoneFalse555241.50
295704897747NoneBOQ187Providing, fabricating and fixing of 10 mm thick Decorative Grooved Bamboo Wood Wall cladding with panel size 1220mmx2440mm, thermal insulation value 2.2 J/g oC & having density 1300Kg/Cum.The base material shall be of MDF and the surface of Bamboo shall be coated with Graphene based PU Coating.The material shall possess special properties such as Fire resistant, Thermal insulation, Sound absorbent and UV & Water resistant.The panel shall be fixed on walls using Mild steel screws or by using special adhesives as per direction of Engineer in charge.Sqm2227.52227.516.0FalseNoneNoneFalseNoneFalse35640.00
295704997747NoneBOQ188Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/Sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T sections shall be pre painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer in charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.Sqm1288.11288.157.0FalseNoneNoneFalseNoneFalse73421.70
295705097747NoneBOQ189b) First floorSqm1300.981300.9812.0FalseNoneNoneFalseNoneFalse15611.760
295705197747NoneBOQ190c) Second FloorSqm1313.861313.8634.0FalseNoneNoneFalseNoneFalse44671.240
295705297747NoneBOQ191Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms/Sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095 (Part I) : 2011 (Board with BIS Certification marks only)Sqm1081.31081.323.0FalseNoneNoneFalseNoneFalse24869.90
295705397747NoneBOQ192b) First floorSqm1092.111092.113.0FalseNoneNoneFalseNoneFalse3276.330
295705497747NoneBOQ193c) Second FloorSqm1102.921102.9213.0FalseNoneNoneFalseNoneFalse14337.960
295705597747NoneBOQ194Providing and fixing VOX Soffit Infratop false ceiling SV 08, panel sizes of 300mmx2700mm , durable and resistant to moisture, water proof and free from borer fungus termite attack, thermal printing technology imitating closer finish to wood, click system for interlocking etc including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. MRSqm3600.03600.012.0FalseNoneNoneFalseNoneFalse43200.00
295705697747NoneBOQ195Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated,tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with Fabric of approved colour and one writing board (600 mm W) and one soft board (600 mm W) per workstation, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway one middle raceway (600mm W) below table top per workstation and continous raceway at the skirting level, Wire manager ABS plastic grommet one number per table, Table top 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware MS powder coated corner bid, cantilever bkt, seperator hook on bkt, L bkt and Table joint plate., as per specifications, drawings and as directed by Engineer in charge.X type 4 wings 1500mmW x 1500mmD 1200mmHNos62000.062000.06.0FalseNoneNoneFalseNoneFalse372000.00
295705797747NoneBOQ196Supplying Black Medium Back Mesh chair of size 585mm(L)x585mm(W)x1040mm(H) with cushion seat and mesh back with cushion arms and nylon base with Pnuematic height adjustable system with wheel rollers complete as per specification. Make: Featherlite/Equivalent MRNos9500.09500.030.0FalseNoneNoneFalseNoneFalse285000.00
295705897747NoneBOQ197Supplying Black Low Back Mesh chair of size 485mm(L)x485mm(W)x1040mm(H) with cushion seat and mesh back with cushion arms and nylon base with Pnuematic height adjustable system with wheel rollers complete as per specification. Make: Featherlite/Equivalent MRNos7500.07500.032.0FalseNoneNoneFalseNoneFalse240000.00
295705997747NoneBOQ198Providing and fixing free standing table for cabin without frames consisting of 25 mm thick PLPB table top, 25mm thick PLPB with edge bomded end table, 18mm thick PLPB with edge bonded modesty wire manager ABS plastic grommet one number per table hardware minfix assembly and screw leg., as per specifications, drawings and as directed by engineer in charge.Main table 2400mmW x750mmD x 750mmH top) Side Table : 900 mm W x 900mm DX 750 mm ht.Nos45000.045000.01.0FalseNoneNoneFalseNoneFalse45000.00
295706097747NoneBOQ199Providing and fixing free standing table for cabin without frames consisting of 25 mm thick PLPB table top, 25mm thick PLPB with edge bomded end table, 18mm thick PLPB with edge bonded modesty wire manager ABS plastic grommet one number per table hardware minfix assembly and screw leg., as per specifications, drawings and as directed by engineer in charge.Main table 2000mmW x750mmD x 750mmH top) Side Table : 900 mm W x 450mm DX 750 mm ht.Nos25000.025000.05.0FalseNoneNoneFalseNoneFalse125000.00
295706197747NoneBOQ200Providing and fixing free standing table for cabin without frames consisting of 25 mm thick PLPB table top, 25mm thick PLPB with edge bomded end table, 18mm thick PLPB with edge bonded modesty wire manager ABS plastic grommet one number per table hardware minfix assembly and screw leg., as per specifications, drawings and as directed by engineer in charge.Main table 1500mmW x750mmD x 750mmH top) Side Table : 900 mm W x 450mm DX 750 mm ht.Nos20000.020000.06.0FalseNoneNoneFalseNoneFalse120000.00
295706297747NoneBOQ201Supplying Liberate High Back Mesh chair of size 660mm(L)x660mm(W)x1250mm(H) with cushion seat and mesh back with cushion arms and chrome plated metal base with Pnuematic height adjustable system with wheel rollers complete as per specification. Make: Featherlite/EquivalentNos20000.020000.016.0FalseNoneNoneFalseNoneFalse320000.00
295706397747NoneBOQ202Providing and fixing 450mmw X 450 mmd X 685 mmht) Mobile pedestal unit WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and one filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock etc.,MRNos5000.05000.020.0FalseNoneNoneFalseNoneFalse100000.00
295706497747NoneBOQ203Wardrobe Providing and fixing wardrobe with 19 mm thick block board with shutters and shelves,.8mm inside & 1.2 mm outside laminate/veneer of approved make on all exposed surfaces including necessary hardware , locks etc.edge painting , polishing etc.complete as per drawings.MRSqm11000.011000.018.0FalseNoneNoneFalseNoneFalse198000.00
295706597747NoneBOQ204Providing and fixing Reception Table In Brown 1 Drawer + 1 shutter unit The PLPB (Wood Base) of Grade II.Nos25000.025000.01.0FalseNoneNoneFalseNoneFalse25000.00
295706697747NoneBOQ205Providing and fixing Self adhesive wall paper for cabin Peel and stick vinyl wall paperSqm400.0400.024.0FalseNoneNoneFalseNoneFalse9600.00
295706797747NoneBOQ206Providing and fixing Record room Racks of following specification.Total Nosof Racks of size 2100mm H X 1300mm W X 450mm D with 3 compartment, Capacity of Flat Files considering 25mm thickness 16000 files (OR) Capacity of Box Files considering 90mm thickness 4480 files, Epoxy Powder Coated Finish, Load Bearing Capacity per Shelf (UDL): 150 Kgs.Single Faced Fixed(A) (5mx0.38mx2.1m)Nos108000.0108000.01.0FalseNoneNoneFalseNoneFalse108000.00
295706897747NoneBOQ207Double Faced Movable (B) (5mx0.76mx2.1m)Nos210000.0210000.07.0FalseNoneNoneFalseNoneFalse1470000.00
295706997747NoneBOQ208Single Faced Movable (C ) (5mx0.45mx2.1m)Nos118200.0118200.01.0FalseNoneNoneFalseNoneFalse118200.00
295707097747NoneBOQ209Providing and fixing storage unit of approved size & 450mm depth made out of 19mm thick commercial ply finished in approved 1.00mm laminate on both external & internal faces of approved colour and shade.Shelves shall be formed out of 19mm ply finished with 1.00mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.00mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification including necessary hardwares & fittings.MRSqm15000.015000.039.0FalseNoneNoneFalseNoneFalse585000.00
295707197747NoneBOQ210Providing & fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in chargeSqm1980.01980.080.0FalseNoneNoneFalseNoneFalse158400.00
295707297747NoneBOQ211Providing and fixing directional signage as per the approved design Size 1'6 x 6 MRNos1500.01500.020.0FalseNoneNoneFalseNoneFalse30000.00
295707397747NoneBOQ212Supply and fixing privacy film on the glass partition MRSqm1750.01750.036.0FalseNoneNoneFalseNoneFalse63000.00
295707497747NoneBOQ213Providing and fixing Three seater Sofa with cushion of size 7(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in chargeNos41250.041250.01.0FalseNoneNoneFalseNoneFalse41250.00
295707597747NoneBOQ214Providing and fixing Waiting Area Chair / 3 Seater Visitor Reception Heavy Chair in Chrome Finish (Stainless Steel)Nos30000.030000.02.0FalseNoneNoneFalseNoneFalse60000.00
295707697747NoneBOQ215Providing and Fixing Hollow acrylic letters or logos which are approximately three inches thick.LEDs are embedded in the hollow space beneath these letters.These 3D letters and logos are mounted on an ACP box frame.This aluminium frame, along with the backlit acrylic letters, are then installed on site.complete as per specification and instructions of the Architect. Letters of BESCOM External logosMRNos45000.045000.02.0FalseNoneNoneFalseNoneFalse90000.00
295707797747NoneBOQ216Providing and Fixing Hollow acrylic letters or logos which are approximately three inches thick.LEDs are embedded in the hollow space beneath these letters.These 3D letters and logos are mounted on an ACP box frame.This aluminium frame, along with the backlit acrylic letters, are then installed on site.complete as per specification and instructions of the Architect. Letters of BESCOM logosMRNos35000.035000.02.0FalseNoneNoneFalseNoneFalse70000.00
295707897747NoneBOQ217Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C.top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) With common burnt clay (non modular) bricks of class designation 3.5Each11622.611622.64.0FalseNoneNoneFalseNoneFalse46490.40
295707997747NoneBOQ218Providing and fixing wash basin with C.I.brackets, 15 mm C.P.brass pillar taps, 32 mm C.P.brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar tapsNos3152.63152.617.0FalseNoneNoneFalseNoneFalse53594.20
295708097747NoneBOQ219Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer in ChargeNos15633.215633.213.0FalseNoneNoneFalseNoneFalse203231.60
295708197747NoneBOQ220Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Class PremiumNos1122.01122.05.0FalseNoneNoneFalseNoneFalse5610.00
295708297747NoneBOQ221Providing and fixing C.P.brass bib cock of approved quality conforming to IS:8931Nos698.5698.530.0FalseNoneNoneFalseNoneFalse20955.00
295708397747NoneBOQ222Providing and fixing C.P.brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.Nos797.5797.530.0FalseNoneNoneFalseNoneFalse23925.00
295708497747NoneBOQ223Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete.Nos1342.01342.06.0FalseNoneNoneFalseNoneFalse8052.00
295708597747NoneBOQ224Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete Class PremiumNos2333.12333.18.0FalseNoneNoneFalseNoneFalse18664.80
295708697747NoneBOQ225Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Class PremiumNos4196.54196.56.0FalseNoneNoneFalseNoneFalse25179.00
295708797747NoneBOQ226Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I.brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mmNos6179.86179.82.0FalseNoneNoneFalseNoneFalse12359.60
295708897747NoneBOQ227Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Class PremiumNos2876.52876.520.0FalseNoneNoneFalseNoneFalse57530.00
295708997747NoneBOQ228Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete Class PremiumNos2109.82109.830.0FalseNoneNoneFalseNoneFalse63294.00
295709097747NoneBOQ229Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P.brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C.automatic flushing cisternNos4899.44899.46.0FalseNoneNoneFalseNoneFalse29396.40
295709197747NoneBOQ230Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm dia pipe nominal OD pipesMtr416.9416.9195.0FalseNoneNoneFalseNoneFalse81295.50
295709297747NoneBOQ231CPVC 25 mm dia pipe nominal OD pipesMtr524.7524.710.0FalseNoneNoneFalseNoneFalse5247.00
295709397747NoneBOQ232Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal boreNos345.4345.42.0FalseNoneNoneFalseNoneFalse690.80
295709497747NoneBOQ233Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 25 mm nominal boreNos603.9603.94.0FalseNoneNoneFalseNoneFalse2415.60
295709597747NoneBOQ234Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 32 mm nominal boreNos657.8657.81.0FalseNoneNoneFalseNoneFalse657.80
295709697747NoneBOQ235Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 40 mm nominal boreNos772.2772.21.0FalseNoneNoneFalseNoneFalse772.20
295709797747NoneBOQ236Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 50 mm nominal boreNos940.5940.525.0FalseNoneNoneFalseNoneFalse23512.50
295709897747NoneBOQ237Providing and fixing P.V.C.waste pipe for sink or wash basin including P.V.C.waste fittings complete.Semi rigid pipe 40 mm diaNos96.896.820.0FalseNoneNoneFalseNoneFalse1936.00
295709997747NoneBOQ238Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms.with soft gravel or selected earth available from the excavation etc.complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.for: PVC pipes 75mm dia., 6 Kg/sqcm & class 3Mtr220.0220.090.0FalseNoneNoneFalseNoneFalse19800.00
295710097747NoneBOQ239Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 75mm dia PVC couplersNos67.067.01.0FalseNoneNoneFalseNoneFalse67.00
295710197747NoneBOQ240Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC ElbowsNos192.0192.01.0FalseNoneNoneFalseNoneFalse192.00
295710297747NoneBOQ241Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC teeNos117.0117.02.0FalseNoneNoneFalseNoneFalse234.00
295710397747NoneBOQ242Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms.with soft gravel or selected earth available from the excavation etc.complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.for: PVC pipes 110mm dia., 6 Kg/sqcm & class 3Mtr411.0411.0112.0FalseNoneNoneFalseNoneFalse46032.00
295710497747NoneBOQ243Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete 110mm dia PVC couplersNos171.0171.06.0FalseNoneNoneFalseNoneFalse1026.00
295710597747NoneBOQ244Supplying of special moulded variety PVC Elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete 110mm dia PVC ElbowsNos302.0302.06.0FalseNoneNoneFalseNoneFalse1812.00
295710697747NoneBOQ245Supplying of special moulded variety PVC Tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete 110mm dia PVC TeeNos251.0251.05.0FalseNoneNoneFalseNoneFalse1255.00
295710797747NoneBOQ246Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories completeNos268.4268.422.0FalseNoneNoneFalseNoneFalse5904.80
295710897747NoneBOQ247Providing and fixing PVC (S.W.R) P Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNos339.9339.916.0FalseNoneNoneFalseNoneFalse5438.40
295710997747NoneBOQ248Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNos380.6380.68.0FalseNoneNoneFalseNoneFalse3044.80
295711097747NoneBOQ249Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNos242.0242.08.0FalseNoneNoneFalseNoneFalse1936.00
295711197747NoneBOQ250Supply and installation of solar heater on terrace, Non pressurized solar heater capacity of 200 litre/day, heat reservation around 72hrs, 2kw Electric capacity.( Tata Bp Solar Water Heater ) MRNos40000.040000.01.0FalseNoneNoneFalseNoneFalse40000.00
295711297747NoneBOQ251Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) 25 mm nominal boreNos603.9603.96.0FalseNoneNoneFalseNoneFalse3623.40
295711397747NoneBOQ252Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 20 mm nominal dia PipesMtr238.7238.7195.0FalseNoneNoneFalseNoneFalse46546.50
295711497747NoneBOQ253CPVC 25 mm dia pipe nominal OD pipesMtr325.6325.6160.0FalseNoneNoneFalseNoneFalse52096.00
295711597747NoneBOQ254CPVC 32 mm dia pipe nominal OD pipesMtr409.2409.2178.0FalseNoneNoneFalseNoneFalse72837.60
295711697747NoneBOQ255CPVC 40 mm dia pipe nominal OD pipesMtr524.7524.780.0FalseNoneNoneFalseNoneFalse41976.00
295711797747NoneBOQ256CPVC 50 mm dia pipe nominal OD pipesMtr793.1793.190.0FalseNoneNoneFalseNoneFalse71379.00
295711897747NoneBOQ257Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr9.99.94000.0FalseNoneNoneFalseNoneFalse39600.00
295711997747NoneBOQ258Providing and fixing of PVC Rungs footrest in under ground tanks/ manhole using Sqm0 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materias, labour, curing etccomplete as per specificationMRNos345.0345.010.0FalseNoneNoneFalseNoneFalse3450.00
295712097747NoneBOQ259Supplying, fixing, testing and commisioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square ) as per approved design.The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified 150 x 150 mm PVC gratingMRNos955.0955.02.0FalseNoneNoneFalseNoneFalse1910.00
295712197747NoneBOQ260Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameterMtr320.1320.125.0FalseNoneNoneFalseNoneFalse8002.50
295712297747NoneBOQ261Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc.excluding the cost of CI frame and cover.Nos5454.05454.02.0FalseNoneNoneFalseNoneFalse10908.00
295712397747NoneBOQ262Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils.Depth upto 1.50mMtr532.4532.435.0FalseNoneNoneFalseNoneFalse18634.00
295712497747NoneBOQ263Supplying, installing, testing and commissioning of submersible electrical driven pump 1set.to lift domestic water with all necessary arrangements to operate on 1HP Single Phase fitted on a common base frame accessories to lift the pump during maintenance, control panel with wiring from TPN switch to control panel and to the pump and the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete.(MR) Duty of the Pump two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.MRNos12500.012500.01.0FalseNoneNoneFalseNoneFalse12500.00
295712597747NoneBOQ264Providing and fixing gun metal non return valve of approved quality (screwed end) :32 mm nominal bore verticalNos764.5764.52.0FalseNoneNoneFalseNoneFalse1529.00
295712697747NoneBOQ265Providing and fixing gun metal non return valve of approved quality (screwed end) :40 mm nominal bore verticalNos1347.51347.52.0FalseNoneNoneFalseNoneFalse2695.00
295712797747NoneBOQ266Supply and fixing 600mm puddle flange consisting of 6mm thick welded MS plate, flanges of suitable size properly fixed in walls of water tanks as per specifications and approved drawings of following diameters. 32 mm diaMRNos800.0800.04.0FalseNoneNoneFalseNoneFalse3200.00
295712897747NoneBOQ267b.40 mm diaMRNos952.0952.04.0FalseNoneNoneFalseNoneFalse3808.00
295712997747NoneBOQ268c.50 mm diaMRNos1200.01200.04.0FalseNoneNoneFalseNoneFalse4800.00
295713097747NoneBOQ269Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc.The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor.The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration.3 Nos.bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually.Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration.Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer in charge.EachEach40000.040000.02.0FalseNoneNoneFalseNoneFalse80000.00
295713197747NoneBOQ270Open Conduit System Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends, junctionboxes, adhesivepasteetc, and fixing using inverted woodplugs incase of RCC ceiling and RCCwall/stone structure or rawlplugs incase of brickwalls and cement plastering the damaged portion using heavygauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr69.069.0250.0FalseNoneNoneFalseNoneFalse17250.00
295713297747NoneBOQ271b.25 mm dia 2 mm thickMtr81.081.0100.0FalseNoneNoneFalseNoneFalse8100.00
295713397747NoneBOQ272c.32 mm dia 2.5 mm thickMtr106.0106.075.0FalseNoneNoneFalseNoneFalse7950.00
295713497747NoneBOQ273Concealed Conduit System Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickMtr66.066.0750.0FalseNoneNoneFalseNoneFalse49500.00
295713597747NoneBOQ274b.25 mm dia 2 mm thickMtr78.078.0950.0FalseNoneNoneFalseNoneFalse74100.00
295713697747NoneBOQ275c.32 mm dia 2.5 mm thickMtr103.0103.0250.0FalseNoneNoneFalseNoneFalse25750.00
295713797747NoneBOQ276Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing UorJ hooks and cement plastering upto the wall surface and run with 18SWG GIfishwire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thickMtr68.068.0100.0FalseNoneNoneFalseNoneFalse6800.00
295713897747NoneBOQ277b.25 mm dia 2 mm thickMtr79.079.0250.0FalseNoneNoneFalseNoneFalse19750.00
295713997747NoneBOQ278c.32 mm dia 2.5 mm thickMtr99.099.030.0FalseNoneNoneFalseNoneFalse2970.00
295714097747NoneBOQ279Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxNos49.049.060.0FalseNoneNoneFalseNoneFalse2940.00
295714197747NoneBOQ280b.25 mm deep Junction boxNos56.056.0180.0FalseNoneNoneFalseNoneFalse10080.00
295714297747NoneBOQ281c.32 mm deep Junction boxNos61.061.030.0FalseNoneNoneFalseNoneFalse1830.00
295714397747NoneBOQ282Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floorMtr69.069.060.0FalseNoneNoneFalseNoneFalse4140.00
295714497747NoneBOQ283Supplying And Fixing Metal Fan Box with Round Hook.S HOK M.S.Rod.Nos117.0117.035.0FalseNoneNoneFalseNoneFalse4095.00
295714597747NoneBOQ284Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for Each outlet.. Short point upto 3m from tapping point to out let via switch boxPoint269.0269.060.0FalseNoneNoneFalseNoneFalse16140.00
295714697747NoneBOQ285Medium point above 3m upto 6m from tapping point to out let via switch boxPoint379.0379.060.0FalseNoneNoneFalseNoneFalse22740.00
295714797747NoneBOQ286Long point above 6m upto 10m from tapping point to out let via switch boxPoint555.0555.040.0FalseNoneNoneFalseNoneFalse22200.00
295714897747NoneBOQ287Two outlet in a row, above 3m upto 6m from tapping point to out let via switchesPoint677.0677.050.0FalseNoneNoneFalseNoneFalse33850.00
295714997747NoneBOQ288Three outlet in a row, above 6m upto 10m from tapping point to out let via switches boxPoint989.0989.010.0FalseNoneNoneFalseNoneFalse9890.00
295715097747NoneBOQ289Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments. 1.5 mSqmMtr26.026.0990.0FalseNoneNoneFalseNoneFalse25740.00
295715197747NoneBOQ290b.2.5 mSqmMtr42.042.03500.0FalseNoneNoneFalseNoneFalse147000.00
295715297747NoneBOQ291c.4 mSqmMtr63.063.01750.0FalseNoneNoneFalseNoneFalse110250.00
295715397747NoneBOQ292d.6 mSqmMtr92.092.0800.0FalseNoneNoneFalseNoneFalse73600.00
295715497747NoneBOQ293e.10 mSqmMtr167.0167.0200.0FalseNoneNoneFalseNoneFalse33400.00
295715597747NoneBOQ294Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1 2 WayNos138.0138.0150.0FalseNoneNoneFalseNoneFalse20700.00
295715697747NoneBOQ295b.3 WayNos159.0159.030.0FalseNoneNoneFalseNoneFalse4770.00
295715797747NoneBOQ296c.4 5 WayNos177.0177.020.0FalseNoneNoneFalseNoneFalse3540.00
295715897747NoneBOQ297d.6 WayNos220.0220.075.0FalseNoneNoneFalseNoneFalse16500.00
295715997747NoneBOQ298e.8 WayNos261.0261.060.0FalseNoneNoneFalseNoneFalse15660.00
295716097747NoneBOQ299f.10 12 WayNos319.0319.015.0FalseNoneNoneFalseNoneFalse4785.00
295716197747NoneBOQ300Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleNos137.0137.0150.0FalseNoneNoneFalseNoneFalse20550.00
295716297747NoneBOQ301b.3 ModuleNos161.0161.030.0FalseNoneNoneFalseNoneFalse4830.00
295716397747NoneBOQ302c.4 ModuleNos175.0175.020.0FalseNoneNoneFalseNoneFalse3500.00
295716497747NoneBOQ303d.6 ModuleNos234.0234.075.0FalseNoneNoneFalseNoneFalse17550.00
295716597747NoneBOQ304e.8 ModuleNos284.0284.012.0FalseNoneNoneFalseNoneFalse3408.00
295716697747NoneBOQ305f.10 12 ModuleNos344.0344.012.0FalseNoneNoneFalseNoneFalse4128.00
295716797747NoneBOQ306Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.. 6A One Way SwitchNos102.0102.0350.0FalseNoneNoneFalseNoneFalse35700.00
295716897747NoneBOQ307b.6A Two Way SwitchNos166.0166.06.0FalseNoneNoneFalseNoneFalse996.00
295716997747NoneBOQ308c.6A Three Way socketNos171.0171.0230.0FalseNoneNoneFalseNoneFalse39330.00
295717097747NoneBOQ309Stepped Fan Regulator Two ModuleNos357.0357.020.0FalseNoneNoneFalseNoneFalse7140.00
295717197747NoneBOQ310b.16A One Way SwitchNos180.0180.030.0FalseNoneNoneFalseNoneFalse5400.00
295717297747NoneBOQ311c.32A DP SwitchNos326.0326.010.0FalseNoneNoneFalseNoneFalse3260.00
295717397747NoneBOQ312d.6/16A Universal SocketNos236.0236.034.0FalseNoneNoneFalseNoneFalse8024.00
295717497747NoneBOQ313TV/Telephone SocketNos156.0156.021.0FalseNoneNoneFalseNoneFalse3276.00
295717597747NoneBOQ314Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439 3 and IK09 Tested as per IS/IEC62262 with minimum IP43 protection provided with Polyurethane(PUR)gasket,with suitable earthing system, on wall/wood board/flush mounting using required clA,bolts,nuts,etc.,with provision for fixing of suitable type capacity MCCB's as an incomer for 3phase Doubledoor with necessary bus bar completely wired touseon 440V3 phase4 wire powder coated painting etc.,complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 2. 4 WAYNos10329.010329.06.0FalseNoneNoneFalseNoneFalse61974.00
295717697747NoneBOQ315b.8 WAYNos12605.012605.06.0FalseNoneNoneFalseNoneFalse75630.00
295717797747NoneBOQ316c.12 WAYNos15529.015529.010.0FalseNoneNoneFalseNoneFalse155290.00
295717897747NoneBOQ317Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Single door 16 Way SP & NNos2932.02932.02.0FalseNoneNoneFalseNoneFalse5864.00
295717997747NoneBOQ318Double Door 8 Way SP & NNos1854.01854.03.0FalseNoneNoneFalseNoneFalse5562.00
295718097747NoneBOQ319Double Door 12 Way SP & NNos2329.02329.05.0FalseNoneNoneFalseNoneFalse11645.00
295718197747NoneBOQ320Supplying, fixing ,wiring, earth electrode for grounding conduits,I.C.cut out sand other equipment's on the meter board using 40 mm dia2.90 mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GI wire of size as per lSI specification 7.3.3.ofI S732 using 12mm dia bolts,nuts,washers and check nutsetc., the pipe shall have 16 through holes of 12 mm dia.Nos3510.03510.04.0FalseNoneNoneFalseNoneFalse14040.00
295718297747NoneBOQ321Supplying and running of GI / copper strips for grounding connections using necessary fixing materials as required GI Strips 25 x 3 mmMtr82.082.0125.0FalseNoneNoneFalseNoneFalse10250.00
295718397747NoneBOQ322b.8 SWG GI WireMtr22.022.075.0FalseNoneNoneFalseNoneFalse1650.00
295718497747NoneBOQ323Providing 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS 1554 (Part 1) or IS 7098 Part 1, Armouring strip thickness and resistivity as per IS 3975. 4 core 50 sqmmKm207194.0207194.00.15FalseNoneNoneFalseNoneFalse31079.10
295718597747NoneBOQ324Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 2.5 sqmm to 25 sqmmMtr20886.020886.00.05FalseNoneNoneFalseNoneFalse1044.30
295718697747NoneBOQ325b.35 sqmm to 95 sqmmMtr31139.031139.00.15FalseNoneNoneFalseNoneFalse4670.850
295718797747NoneBOQ326Supplying and fixing of heavy duty cable glands suitable for UG cable off 1.1 KV class (metal only). 19/20/25 mmMtr75.075.012.0FalseNoneNoneFalseNoneFalse900.00
295718897747NoneBOQ327b.32 mmMtr90.090.04.0FalseNoneNoneFalseNoneFalse360.00
295718997747NoneBOQ328Supplying exhaust fan of 1440 RPM of 300 mm (12) size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Nos1492.01492.020.0FalseNoneNoneFalseNoneFalse29840.00
295719097747NoneBOQ329Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/ 10 percentage, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/ 10percentage RPM, Rated air delivery 210 +/ 10percentage Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding.Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48 Sweep 5 Star (1200 mm)Nos2677.02677.035.0FalseNoneNoneFalseNoneFalse93695.00
295719197747NoneBOQ330Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires.Nos198.0198.010.0FalseNoneNoneFalseNoneFalse1980.00
295719297747NoneBOQ331Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / GirdersNos122.0122.0270.0FalseNoneNoneFalseNoneFalse32940.00
295719397747NoneBOQ332Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A.ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Nos315.0315.035.0FalseNoneNoneFalseNoneFalse11025.00
295719497747NoneBOQ333Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A.ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Nos492.0492.020.0FalseNoneNoneFalseNoneFalse9840.00
295719597747NoneBOQ334Light fixtures : Supply of 15 W LED bulk head fitting with guard, Acrylic glass and suitable driverMRNos1680.01680.015.0FalseNoneNoneFalseNoneFalse25200.00
295719697747NoneBOQ335Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70percentage lumen maintenance with CRI greater than 80.Power Input: 220 240V@ 50/60Hz & Power factor greater than0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.. LED light fitting 1 x 2' 9/10 WNos551.0551.010.0FalseNoneNoneFalseNoneFalse5510.00
295719797747NoneBOQ336LED light fitting 1 x 4' 20/22 WNos690.0690.055.0FalseNoneNoneFalseNoneFalse37950.00
295719897747NoneBOQ337Supplying of recess mounting non integrated type LED down light......W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70percentage.efficacy greater than100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80.The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level.LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldlesser than 5percentage of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.. 5 6 WNos805.0805.0100.0FalseNoneNoneFalseNoneFalse80500.00
295719997747NoneBOQ338Supplying of recess mounting non integral type........LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIgreater than 70percentage.efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldlesser than 5percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20percentage, Life as per LM 79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.. LED modular down light 2'x2' 36 WNos4553.04553.050.0FalseNoneNoneFalseNoneFalse227650.00
295720097747NoneBOQ339Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70percentage, maximum light intensity should be between 60 degrees to 70 degrees.CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08.Power Factor greater than0.9 with mains, Surge Protection Min 5KV along with Over voltage/ Overload, short circuit/ miss wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application.Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with........W System Power consumption.LED Efficiencygreater than1301m/w, nominal CRI greater than75.Luminaire manufacturer should have in house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part.Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned. LED Streetlight 40WNos4024.04024.02.0FalseNoneNoneFalseNoneFalse8048.00
295720197747NoneBOQ340Supply of LED Bollard light fitting of...W with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70percentage, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08.Power Factor greater than0.9 with mains, Surge Protection Min 5KV along with Over voltage/Overload, short circuit/ miss wiring protection.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application.Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS.UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 m HeightNos4528.954528.955.0FalseNoneNoneFalseNoneFalse22644.750
295720297747NoneBOQ341Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for outdoor luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.. Single Arm Bracket with 1000 mm Standard 40/50 mm diaNos1700.01700.05.0FalseNoneNoneFalseNoneFalse8500.00
295720397747NoneBOQ342Fabricating supplying and mounting MSbox madeout....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cableentry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.. 14 SWGSq CM0.50.550000.0FalseNoneNoneFalseNoneFalse25000.00
295720497747NoneBOQ343Fabricating supplying and mounting MS box made out...SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enaemeld metal paint etc., complete.. 75x75x6 mmMtr555.0555.04.0FalseNoneNoneFalseNoneFalse2220.00
295720597747NoneBOQ344Supplying....amps rated 3 phase with neutral bus bar using requred capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts 5.40.1 and washers etc., complete.. 100Amps 4x30x6mm Aluminum Strips.Mtr2465.02465.04.0FalseNoneNoneFalseNoneFalse9860.00
295720697747NoneBOQ345Supplying of multi function meter digital three line back light LCD type display of voltage, current, current, frequency, power, power factor, KVA , KWH, KVAR.suitable for 3phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication port and class 0.5s accuracyNos9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
295720797747NoneBOQ346Supplying, fixing and wiring 50/5 to 400/5A 5VA burden current transformer.Class 0.5 accuracy with tape wound.Nos562.0562.02.0FalseNoneNoneFalseNoneFalse1124.00
295720897747NoneBOQ347Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12/24V DCNos515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
295720997747NoneBOQ348Supplying fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest mnicrocontroller based, digital read out of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/flush mounting panel boardNos9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
295721097747NoneBOQ349Supply and fixing Moulded case circuit breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete.Protection of overload and short circuit with thermal magnetic/micro processor releases and earth fault as per IS 13947 Four pole. 100Amps 25kANos8487.08487.01.0FalseNoneNoneFalseNoneFalse8487.00
295721197747NoneBOQ350Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross 3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899. 6 32 Amps SPNos415.0415.03.0FalseNoneNoneFalseNoneFalse1245.00
295721297747NoneBOQ351b.6 32 Amps DPNos739.0739.05.0FalseNoneNoneFalseNoneFalse3695.00
295721397747NoneBOQ352c.6 32 Amps TPNNos1717.01717.04.0FalseNoneNoneFalseNoneFalse6868.00
295721497747NoneBOQ353d.40 Amps TPNNos3044.03044.04.0FalseNoneNoneFalseNoneFalse12176.00
295721597747NoneBOQ354Supplying, erecting, testing & commissioning of OFF LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete.. 3 kVA OFF LINE UPSNos29142.029142.01.0FalseNoneNoneFalseNoneFalse29142.00
295721697747NoneBOQ355Supplying, installation, testing and commissioning of 12 volts DC AH batteries in poly propylene container for UPS sealed maintainence free batteries. 12V, 75 80 AH capacity.Acoid batteryNos10172.010172.03.0FalseNoneNoneFalseNoneFalse30516.00
295721797747NoneBOQ356Design, supplying, erecting testing and commissioning of Passenger/Bed cum passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or with out machine roomf or the available wellsize,operating at 415 V3 phase 50 cycles AC supply, powder coated/Stainless Steel carentrance door sen closures with suitable colourvinyl flooring, LED carillumination, emergency light, intercomand fan as desired by the user, central opening/side opening door with or without attend antoperation, 7segment display buttons, call register indicator, firemandrive, SShandrails insidecar, fulllength infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guiderail, counterweight etc., The total product and services shall adhere to IS14665/2016 (with latest amendments part/section 1 to 5 with regards togeneral guidelines offire safety rated doors, MRLL beams, pressures witch, manual change over for doors during emergency, ARD of 10times with sufficient battery backup and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCBNorms, National Electricity Code(NEC), NBC 2016,IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014.The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka.With Out Machine Room SS Finish 13 passengers 3 stopsNos1736522.271736522.271.0FalseNoneNoneFalseNoneFalse1736522.270
295721897747NoneBOQ357Supplying & Laying cable trays including welding, fixing of supports Cable tray of 600 mm width (suitable for cable ducts of A, B & C type)Mtr1064.01064.065.0FalseNoneNoneFalseNoneFalse69160.00
295721997747NoneBOQ358Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.GROUP A a) TV/ Telephone socketEach156.0156.025.0FalseNoneNoneFalseNoneFalse3900.00
295722097747NoneBOQ359b) RJ45/I.O.outletEach337.0337.045.0FalseNoneNoneFalseNoneFalse15165.00
295722197747NoneBOQ360Supplying and drawing UTP CAT 6E LAN cable.Mtr38.038.01500.0FalseNoneNoneFalseNoneFalse57000.00
295722297747NoneBOQ361Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable.a) 2 PairMtr21.021.0600.0FalseNoneNoneFalseNoneFalse12600.00
295722397747NoneBOQ362Supplying and fixing of switch mounting rack with power manager & cable manager.6U with 450mm depthEach6977.06977.02.0FalseNoneNoneFalseNoneFalse13954.00
295722497747NoneBOQ363Supplying and fixing of power strip.Each1457.01457.02.0FalseNoneNoneFalseNoneFalse2914.00
295722597747NoneBOQ364Supplying and fixing of fan.Each1209.01209.02.0FalseNoneNoneFalseNoneFalse2418.00
295722697747NoneBOQ365Supplying & fixing of ….mtrs Cat6 Patch Cable a) 1 mtrEach224.0224.045.0FalseNoneNoneFalseNoneFalse10080.00
295722797747NoneBOQ366Supplying & fixing of ….mtrs Cat6 Patch Cable b) 2 mtrEach257.0257.045.0FalseNoneNoneFalseNoneFalse11565.00
295722897747NoneBOQ367Supplying & fixing of Patch Panel for LAN cabling.24 Port 10/100/1000 Patch PanelEach4100.04100.02.0FalseNoneNoneFalseNoneFalse8200.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17098053400000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17098053400000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17098053400000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17098053570000NoneNoneELIGIBILITYAll other terms and conditions as per NIT and KW4None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneThe bidders shall upload the work done certificate for minimum quantities of work executed in any one year, following quantities (In a continuous period of 12 months from April to March) in the last 5 years (i.e. F/Y 2018-19 to F/Y 2022-23) the certificate shall be issued by the officer not below the rank of Executive Engineer or equivalent. a.PCC/RCC 370.00 .00 Cum b.Burnt brick masonry/Solid block 160.00Cum / 800.00 Sqm c.TMT steel reinforcement 34.50.00 Tonnes d.Vitrified / Ceramic / Granite flooring 1660.00 SqmPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum Quantities Certificate as per NIT and KW4
NoneNoneNoneNoneThe bidders shall upload the work done certificate for having executed One building work of value not less than Rs. 193.50 lakhs and completed satisfactorily as a prime contractor within stipulated time period in the past 5 years (i.e., 2018-19 to 2022-23). Work done certificate shall be duly signed by the officer not below the rank of Executive Engineer or equivalent.(Note: Work done amount will be updated to the FY 2023-24 in which the tenders are invited. The value of the completed works will be given a weight of 10% per year to bring them to the price level of the FY 2023-24 in which the tenders are invited)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- workdone certificate as per NIT and KW4
NoneNoneNoneNoneThe bidders shall achieved turnover for an amount not less than Rs.772.00 lakhs achieved in any two financial years in the past 5 years (i.e.2018-19 to 2022-23) (in all classes of civil engineering construction works only). The Turnover certificate along with Balance sheet and P & L statement of past 5 years for the Civil Engineering works only (i.e.2018-19 to 2022-23) issued from a Registered Chartered Accountant (Registered Chartered Accountant PIN must be mentioned) should be uploaded. (Note: The turnover amount will be updated to the FY 2022-23 in which the tenders are invited. The Financial turnover of previous years will be given a weightage of 10% per year to bring them to the price level of the FY 2022-23 in which the tenders are invited)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4
NoneNoneNoneNoneThe bidder/tenderer or his identified Sub contractor should upload required valid electrical licence along with consent / undertaking letter for executing building electrification works and should have executed similar electrical works totalling for Rs.19.50 lakhs in any one year in the last 5 years, (i.e. 2018-19 to 2022-23) signed by the officer not below the rank of Executive Engineer or equivalent for Electrical works.OthersElectrical licence, consent letter and Electrical workdone as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Electrical licence, consent letter and Electrical workdone as per NIT and KW4
NoneNoneNoneNoneThe bidder/tenderer or his identified Sub contractor should upload required valid PHE licence along with consent / undertaking letter for executing Water supply / Sanitary engineering works and should have executed similar Water supply / sanitary engineering works /PHE works totalling for Rs.6.50 lakhs in any one year in the last 5 years,(i.e. 2018-19 to 2022-23),signed by the officer not below the rank of Executive Engineer or equivalent for Water supply / sanitary engineering works /PHE works.OthersWater supply licence, consent letter and Water supply workdone as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Water supply licence, consent letter and Water supply workdone as per NIT and KW4
NoneNoneNoneNoneThe banker certificate as per the enclosed format shall be uploaded for availability of fund requirement for the work not less Rs.116.00 Lakhs issued by Nationalised or Scheduled Bank after this notification date, with following details.1. Cash at Bank 2.Term deposits 3.Credit facility sanctioned a. Credit Utilized b. Balance credit facility availableOthersBanker certificate As per Enclosed format as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker certificate As per Enclosed format as per NIT and KW4
NoneNoneNoneNoneBidder shall upload the self-declaration affidavit as per the enclosed format on the stamp paper of value not less than Rs. 100/- duly notarized stating that a.Not made any misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements.b. Not made any Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion or financial failures etc. c.Not participated in the previous Tender for the same work and had quoted unreasonably high tender prices and could not furnish rational justification. d.No Litigation History or arbitration arising out of contracts completed or under execution by it over the preceding five yearsOthersself-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
NoneNoneNoneNoneThe bidders shall upload a valid registered KPWD Civil contractor Licence of Class II and above.OthersKPWD Registration Certificate as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Registration Certificate as per NIT and KW4
NoneNoneNoneNoneAll other terms and conditions as per NIT and KW4OthersAll other terms and conditions as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- All other terms and conditions as per NIT and KW4
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Registration Certificate as per NIT and KW4TrueTechnical Bid
Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4TrueTechnical Bid
workdone certificate as per NIT and KW4TrueTechnical Bid
Minimum Quantities Certificate as per NIT and KW4TrueTechnical Bid
Electrical licence, consent letter and Electrical workdone as per NIT and KW4TrueTechnical Bid
Water supply licence, consent letter and Water supply workdone as per NIT and KW4TrueTechnical Bid
Banker certificate As per Enclosed format as per NIT and KW4TrueTechnical Bid
Bid Capacity as per NIT and KW4TrueTechnical Bid
self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709829591000
version0
createdDateNone
modifiedDateNone
blockNumberFirst floor, Belaku Bhavana, BESCOM Corporate office, K R Circle, Bengaluru
streetNone
cityBengaluru
stateKarnataka
pin560001
tenderRecallDTONone