createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1709808872891
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd525000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose10-04-2024 16:00:00
tenderQueryClose02-04-2024 16:00:00
technicalBidOpen12-04-2024 16:05:00
publishedDate11-03-2024 11:29:18
publishedByPostBESCOM_GM_CIV_BNG
publishedByUserKPE16137 - T G RAMAKRISHNA
bidValidityPeriod120
noOfCalls1
preBidMeetingDate21-03-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonT G Ramakrishna
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8277892569
tenderSupplierListNone
tenderSchedule
createdTs1709808872946
version15
createdDateNone
modifiedDateNone
tenderNumberBESCOM/2023-24/BD/WORK_INDENT147
titleConstruction of C8 sub division office building, indoor/outdoor stores in the space gifted to BESCOM by MCEHCS Layout, Jakkur (Shivaram Karanth Nagara)
descriptionConstruction of C8 sub division office building, indoor/outdoor stores in the space gifted to BESCOM by MCEHCS Layout, Jakkur (Shivaram Karanth Nagara)
categoryWORKS
categoryTextWorks
ecv34998742.60
deptNameBangalore Electricity Supply Company Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3834
locationNameBESCOM Corporate Office Civil Section Bengaluru
provisionalAmount35000000.0
groupOverheadTotal5338791.24
fileNumberBESCOM/GM/Civil/2023-24/39
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17098088730001NoneNoneBuildingsConstruction of C8 sub division office building, indoor/outdoor stores in the space gifted to BESCOM by MCEHCS Layout, Jakkur (Shivaram Karanth Nagara)29659951.36
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
296133797889NoneBOQ01Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge.Cum1829.31829.325.0FalseNoneNoneFalseNoneFalse45732.50
296133897889NoneBOQ02Demolishing R.C.C.work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Ground floorCum2668.62668.62.0FalseNoneNoneFalseNoneFalse5337.20
296133997889NoneBOQ03Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge.Cum530.2530.27.0FalseNoneNoneFalseNoneFalse3711.40
296134097889NoneBOQ04Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge to the appropriate disposal area.Cum400.4400.434.0FalseNoneNoneFalseNoneFalse13613.60
296134197889NoneBOQ05Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.By Manual Means In area of light jungle100 Sqm1234.21234.26.0FalseNoneNoneFalseNoneFalse7405.20
296134297889NoneBOQ06Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum100.1100.125.0FalseNoneNoneFalseNoneFalse2502.50
296134397889NoneBOQ07Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum266.2266.2784.0FalseNoneNoneFalseNoneFalse208700.80
296134497889NoneBOQ08Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum284.9284.960.0FalseNoneNoneFalseNoneFalse17094.00
296134597889NoneBOQ09Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc.in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum292.6292.699.0FalseNoneNoneFalseNoneFalse28967.40
296134697889NoneBOQ10Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum521.4521.4100.0FalseNoneNoneFalseNoneFalse52140.00
296134797889NoneBOQ11Providing, packing & laying Boulder stone soiling 150mm depth in plinth beam & other places using 150mm granite stones packing with stone chips.The surface shall be consolidated manually or any other approved methods of consolidation after spreading good quality moorum up to 33% by volume of soling metal and though watering etc.Complete.MRSqm450.0450.0151.0FalseNoneNoneFalseNoneFalse67950.00
296134897889NoneBOQ12Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C./ Lindane 20% E.C.@ 3.19 l/Sqm including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm129.8129.8336.89FalseNoneNoneFalseNoneFalse43728.3220
296134997889NoneBOQ13Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum6230.46230.423.0FalseNoneNoneFalseNoneFalse143299.20
296135097889NoneBOQ14Providing and laying in position Cement Concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregatesCum6838.76838.725.26FalseNoneNoneFalseNoneFalse172745.5620
296135197889NoneBOQ15Terrace FloorCum7043.867043.8625.27FalseNoneNoneFalseNoneFalse177998.34220
296135297889NoneBOQ16Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc.The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications Sqm0 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6955.36955.333.69FalseNoneNoneFalseNoneFalse234324.0570
296135397889NoneBOQ17Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.Sqm5 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6969.66969.6110.27FalseNoneNoneFalseNoneFalse768537.7920
296135497889NoneBOQ18Additionalities for form work for Isolated Footing @ 8%Cum557.57557.5740.79FalseNoneNoneFalseNoneFalse22743.28030
296135597889NoneBOQ19Additionalities for form work for columns & walls upto plinth beam @ 70%Cum4878.714878.7117.73FalseNoneNoneFalseNoneFalse86499.52830
296135697889NoneBOQ20Additionalities for form work for plinth beam @ 50%Cum3484.83484.810.36FalseNoneNoneFalseNoneFalse36102.5280
296135797889NoneBOQ21Additionalities for form work for slab @ 50%Cum3484.83484.83.84FalseNoneNoneFalseNoneFalse13381.6320
296135897889NoneBOQ22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) Sqm0 Design Mix Using 25 mm nominal size graded crushed coarse aggregatesCum7527.37527.368.27FalseNoneNoneFalseNoneFalse513888.7710
296135997889NoneBOQ23b) First FloorCum7602.567602.5669.12FalseNoneNoneFalseNoneFalse525488.94720
296136097889NoneBOQ24c) Second FloorCum7677.847677.8473.6FalseNoneNoneFalseNoneFalse565089.0240
296136197889NoneBOQ25c) Terrace FloorCum7753.117753.113.59FalseNoneNoneFalseNoneFalse27833.66490
296136297889NoneBOQ26Additionalities for form work for columns @ 70%- Ground floorCum5269.15269.110.09FalseNoneNoneFalseNoneFalse53165.2190
296136397889NoneBOQ27Additionalities for form work for columns @ 70%- First floorCum5321.85321.810.094FalseNoneNoneFalseNoneFalse53718.24920
296136497889NoneBOQ28Additionalities for form work for columns @ 70%- c) Second FloorCum5374.495374.4910.09FalseNoneNoneFalseNoneFalse54228.60410
296136597889NoneBOQ29Additionalities for form work for columns @ 70%- c) Terrace FloorCum5427.185427.181.32FalseNoneNoneFalseNoneFalse7163.87760
296136697889NoneBOQ30Additionalities for form work for Roof beam, Lintel beam @ 60%- Ground floorCum4516.374516.3714.7FalseNoneNoneFalseNoneFalse66390.6390
296136797889NoneBOQ31Additionalities for form work for Roof beam, Lintel beam @ 60%- First floorCum4561.544561.5415.33FalseNoneNoneFalseNoneFalse69928.40820
296136897889NoneBOQ32Additionalities for form work for Roof beam, Lintel beam @ 60%- c) Second FloorCum4606.74606.720.18FalseNoneNoneFalseNoneFalse92963.2060
296136997889NoneBOQ33Additionalities for form work for Roof beam, Lintel beam @ 60%- d) Terrace FloorCum4651.874651.870.59FalseNoneNoneFalseNoneFalse2744.60330
296137097889NoneBOQ34Additionalities for form work for Roof slab @ 50%- Ground floorCum3763.643763.6437.1FalseNoneNoneFalseNoneFalse139631.0440
296137197889NoneBOQ35Additionalities for form work for Roof slab @ 50%- First floorCum3801.283801.2837.1FalseNoneNoneFalseNoneFalse141027.4880
296137297889NoneBOQ36Additionalities for form work for Roof slab @ 50%- c) Second FloorCum3838.913838.9137.1FalseNoneNoneFalseNoneFalse142423.5610
296137397889NoneBOQ37Additionalities for form work for Roof slab @ 50%- c) Terrace FloorCum3876.553876.551.78FalseNoneNoneFalseNoneFalse6900.2590
296137497889NoneBOQ38Additionalities for form work for Chajja @ 45%- Ground floorCum3387.283387.280.9FalseNoneNoneFalseNoneFalse3048.5520
296137597889NoneBOQ39Additionalities for form work for Chajja @ 45%- First floorCum3421.153421.151.09FalseNoneNoneFalseNoneFalse3729.05350
296137697889NoneBOQ40Additionalities for form work for Chajja @ 45%- Second floorCum3455.023455.020.73FalseNoneNoneFalseNoneFalse2522.16460
296137797889NoneBOQ41Additionalities for form work for Chajja @ 45%- Terrace floorCum3488.93488.91.794FalseNoneNoneFalseNoneFalse6259.08660
296137897889NoneBOQ42Additionalities for form work for Staircase @ 45%- Ground floorCum3387.293387.295.48FalseNoneNoneFalseNoneFalse18562.34920
296137997889NoneBOQ43Additionalities for form work for Staircase @ 45%- First floorCum3421.163421.165.48FalseNoneNoneFalseNoneFalse18747.95680
296138097889NoneBOQ44Additionalities for form work for Staircase @ 45%- Second floorCum3455.033455.035.48FalseNoneNoneFalseNoneFalse18933.56440
296138197889NoneBOQ45Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Ground floorTonne98402.798402.718.04FalseNoneNoneFalseNoneFalse1775184.7080
296138297889NoneBOQ46b) First FloorTonne99386.7399386.739.77FalseNoneNoneFalseNoneFalse971008.35210
296138397889NoneBOQ47c) Second FloorTonne100370.75100370.7510.63FalseNoneNoneFalseNoneFalse1066941.07250
296138497889NoneBOQ48d)Terrace FloorTonne101354.78101354.780.65FalseNoneNoneFalseNoneFalse65880.6070
296138597889NoneBOQ49Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum7027.97027.946.0FalseNoneNoneFalseNoneFalse323283.40
296138697889NoneBOQ50Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-chargeSqm280.5280.597.0FalseNoneNoneFalseNoneFalse27208.50
296138797889NoneBOQ51Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800Kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.a) Ground floorSqm1441.01441.0369.0FalseNoneNoneFalseNoneFalse531729.00
296138897889NoneBOQ52b) First floorSqm1455.41455.4382.0FalseNoneNoneFalseNoneFalse555962.80
296138997889NoneBOQ53c) Second FloorSqm1469.821469.82341.0FalseNoneNoneFalseNoneFalse501208.620
296139097889NoneBOQ54d)Terrace FloorSqm1484.231484.2346.0FalseNoneNoneFalseNoneFalse68274.580
296139197889NoneBOQ55Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800Kg/Cum and minimum compressive strength of 4.00 N/mSqm conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.a) Ground floorSqm1214.41214.469.0FalseNoneNoneFalseNoneFalse83793.60
296139297889NoneBOQ56b) First floorSqm1226.541226.5469.0FalseNoneNoneFalseNoneFalse84631.260
296139397889NoneBOQ57c) Second FloorSqm1238.681238.6869.0FalseNoneNoneFalseNoneFalse85468.920
296139497889NoneBOQ58Providing and fixing in position Fixed 10mm toughened glass as fixed glass from Floor to available Ceiling level for Partitions.The work includes cost of all materials, approved hardware, fixing the same as per site conditions to a neat finished work as per drawings and directions etc., complete.Sqm6250.06250.098.0FalseNoneNoneFalseNoneFalse612500.00
296139597889NoneBOQ59b) First floorSqm6312.56312.576.0FalseNoneNoneFalseNoneFalse479750.00
296139697889NoneBOQ60c) Second FloorSqm6375.06375.087.0FalseNoneNoneFalseNoneFalse554625.00
296139797889NoneBOQ61Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc.for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.200mm lengthSqm5194.25194.216.2FalseNoneNoneFalseNoneFalse84146.040
296139897889NoneBOQ62b) First floorSqm5246.145246.1410.5FalseNoneNoneFalseNoneFalse55084.470
296139997889NoneBOQ63c) Second FloorSqm5298.085298.0813.9FalseNoneNoneFalseNoneFalse73643.3120
296140097889NoneBOQ64Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc.complete as per direction of Engineer-incharge.200mm lengthNos1650.01650.014.0FalseNoneNoneFalseNoneFalse23100.00
296140197889NoneBOQ65b) First floorNos1666.51666.510.0FalseNoneNoneFalseNoneFalse16665.00
296140297889NoneBOQ66c) Second FloorNos1683.01683.012.0FalseNoneNoneFalseNoneFalse20196.00
296140397889NoneBOQ67Glass door locksSqm1500.01500.07.0FalseNoneNoneFalseNoneFalse10500.00
296140497889NoneBOQ68b) First floorSqm1515.01515.05.0FalseNoneNoneFalseNoneFalse7575.00
296140597889NoneBOQ69c) Second FloorSqm1530.01530.06.0FalseNoneNoneFalseNoneFalse9180.00
296140697889NoneBOQ70Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 Kg/Cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mSqm , modulus of elasticity 900 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge.(Fixtures shall be paid for separately) Size 62 x 100mmMtr772.2772.213.3FalseNoneNoneFalseNoneFalse10270.260
296140797889NoneBOQ71b) First floorMtr779.92779.9210.5FalseNoneNoneFalseNoneFalse8189.160
296140897889NoneBOQ72c) Second FloorMtr787.64787.6412.6FalseNoneNoneFalseNoneFalse9924.2640
296140997889NoneBOQ73Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 Kg/Cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mSqm , modulus of elasticity 850 N/mSqm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thicknessSqm4445.14445.110.4FalseNoneNoneFalseNoneFalse46229.040
296141097889NoneBOQ74b) First floorSqm4489.554489.5514.2FalseNoneNoneFalseNoneFalse63751.610
296141197889NoneBOQ75c) Second FloorSqm4534.04534.014.2FalseNoneNoneFalseNoneFalse64382.80
296141297889NoneBOQ76Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.completeNos143.0143.018.0FalseNoneNoneFalseNoneFalse2574.00
296141397889NoneBOQ77b) First floorNos144.43144.4315.0FalseNoneNoneFalseNoneFalse2166.450
296141497889NoneBOQ78c) Second FloorNos145.85145.8515.0FalseNoneNoneFalseNoneFalse2187.750
296141597889NoneBOQ79Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc.completeNos260.7260.712.0FalseNoneNoneFalseNoneFalse3128.40
296141697889NoneBOQ80b) First floorNos263.3263.310.0FalseNoneNoneFalseNoneFalse2633.00
296141797889NoneBOQ81c) Second FloorNos265.91265.9110.0FalseNoneNoneFalseNoneFalse2659.10
296141897889NoneBOQ82Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats, square or round bars etc.including priming coat with approved steel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc.a) Ground floorKg201.3201.3501.0FalseNoneNoneFalseNoneFalse100851.30
296141997889NoneBOQ83b) First floorKg203.31203.31338.0FalseNoneNoneFalseNoneFalse68718.780
296142097889NoneBOQ84c) Second FloorKg205.32205.32338.0FalseNoneNoneFalseNoneFalse69398.160
296142197889NoneBOQ85Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm.Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm.Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock.Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size 2419mm x 2200mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) a) Ground floorSqm7407.47407.424.0FalseNoneNoneFalseNoneFalse177777.60
296142297889NoneBOQ86b) First floorSqm7481.477481.4717.0FalseNoneNoneFalseNoneFalse127184.990
296142397889NoneBOQ87c) Second FloorSqm7555.547555.5417.0FalseNoneNoneFalseNoneFalse128444.180
296142497889NoneBOQ88d)Terrace FloorSqm7629.627629.622.0FalseNoneNoneFalseNoneFalse15259.240
296142597889NoneBOQ89Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg745.8745.8435.0FalseNoneNoneFalseNoneFalse324423.00
296142697889NoneBOQ90b) First floorKg627.71627.71435.0FalseNoneNoneFalseNoneFalse273053.850
296142797889NoneBOQ91c) Second FloorKg633.93633.93435.0FalseNoneNoneFalseNoneFalse275759.550
296142897889NoneBOQ92Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc.complete.Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg194.04194.041050.0FalseNoneNoneFalseNoneFalse203742.00
296142997889NoneBOQ93Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kg179.51179.51950.0FalseNoneNoneFalseNoneFalse170534.50
296143097889NoneBOQ94Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm9103.69103.612.0FalseNoneNoneFalseNoneFalse109243.20
296143197889NoneBOQ95Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.Cum151881.4151881.40.3FalseNoneNoneFalseNoneFalse45564.420
296143297889NoneBOQ96b) First floorCum153400.21153400.210.1FalseNoneNoneFalseNoneFalse15340.0210
296143397889NoneBOQ97c) Second FloorCum154919.02154919.020.1FalseNoneNoneFalseNoneFalse15491.9020
296143497889NoneBOQ98Providing and fixing in position Honnewood fully panelled shutters for windows with stiles and rails of 35mm.thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications.(excluding cost of fixtures)Sqm8331.48331.47.6FalseNoneNoneFalseNoneFalse63318.640
296143597889NoneBOQ99b) First floorSqm8414.718414.712.1FalseNoneNoneFalseNoneFalse17670.8910
296143697889NoneBOQ100c) Second FloorSqm8498.028498.022.9FalseNoneNoneFalseNoneFalse24644.2580
296143797889NoneBOQ101Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m.including cost of materials, labour charges, complete as per specifications.Nos1117.61117.63.0FalseNoneNoneFalseNoneFalse3352.80
296143897889NoneBOQ102b) First floorNos1128.771128.771.0FalseNoneNoneFalseNoneFalse1128.770
296143997889NoneBOQ103c) Second FloorNos1139.951139.951.0FalseNoneNoneFalseNoneFalse1139.950
296144097889NoneBOQ104Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete.Nos1157.21157.23.0FalseNoneNoneFalseNoneFalse3471.60
296144197889NoneBOQ105b) First floorNos1168.771168.771.0FalseNoneNoneFalseNoneFalse1168.770
296144297889NoneBOQ106c) Second FloorNos1180.341180.341.0FalseNoneNoneFalseNoneFalse1180.340
296144397889NoneBOQ107Providing and fixing bright finished brass handles with screws etc.complete: Brass handles 125 mm with plate 175x32 mmEach273.9273.93.0FalseNoneNoneFalseNoneFalse821.70
296144497889NoneBOQ108b) First floorEach276.63276.631.0FalseNoneNoneFalseNoneFalse276.630
296144597889NoneBOQ109c) Second FloorEach279.37279.371.0FalseNoneNoneFalseNoneFalse279.370
296144697889NoneBOQ110Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 250x10mmNos220.0220.03.0FalseNoneNoneFalseNoneFalse660.00
296144797889NoneBOQ111b) First floorNos222.2222.21.0FalseNoneNoneFalseNoneFalse222.20
296144897889NoneBOQ112c) Second FloorNos224.4224.41.0FalseNoneNoneFalseNoneFalse224.40
296144997889NoneBOQ113Providing and fixing PTMT door catcher of length 72 mm and dia.of 42 mm with suitable washers weighing not less than 33 gmsNos60.560.53.0FalseNoneNoneFalseNoneFalse181.50
296145097889NoneBOQ114b) First floorNos61.161.11.0FalseNoneNoneFalseNoneFalse61.10
296145197889NoneBOQ115c) Second FloorNos61.7161.711.0FalseNoneNoneFalseNoneFalse61.710
296145297889NoneBOQ116Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1.The surface to be polished is rubbed with sand paper 80/120 Nosand then with sand paper of 160/180 nos.2.Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc.Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4.On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion.This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs.The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge.(Final coat to be done in 1 or 2 layers without gap of time.)Sqm744.7744.77.6FalseNoneNoneFalseNoneFalse5659.720
296145397889NoneBOQ117b) First floorSqm752.14752.142.1FalseNoneNoneFalseNoneFalse1579.4940
296145497889NoneBOQ118c) Second FloorSqm759.59759.592.9FalseNoneNoneFalseNoneFalse2202.8110
296145597889NoneBOQ119Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6 Kg/Sqm to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/Sqm and protection with 120gsm Geo-textile over the waterproofing membrane.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sqm925.66925.66318.0FalseNoneNoneFalseNoneFalse294359.880
296145697889NoneBOQ120Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per Sqm,having tensile strength greater than 1.5N/mSqm, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/Sqm, and spreading 60 gsm geotextile between two top coats completely as per specification.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In chargeSqm810.7810.761.19FalseNoneNoneFalseNoneFalse49606.7330
296145797889NoneBOQ121Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x1200 mmSqm1445.41445.4199.0FalseNoneNoneFalseNoneFalse287634.60
296145897889NoneBOQ122b) First floorSqm1459.851459.85229.0FalseNoneNoneFalseNoneFalse334305.650
296145997889NoneBOQ123c) Second FloorSqm1474.31474.3182.0FalseNoneNoneFalseNoneFalse268322.60
296146097889NoneBOQ124Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/ Sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mmSqm1259.51259.521.0FalseNoneNoneFalseNoneFalse26449.50
296146197889NoneBOQ125b) First floorSqm1272.091272.0921.0FalseNoneNoneFalseNoneFalse26713.890
296146297889NoneBOQ126c) Second FloorSqm1284.691284.6921.0FalseNoneNoneFalseNoneFalse26978.490
296146397889NoneBOQ127Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge.d) Terrace FloorSqm1591.861591.86318.0FalseNoneNoneFalseNoneFalse506211.480
296146497889NoneBOQ128Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 Kg of organic coated filler of desired shade (0.10 Kg of hardener and 0.20 Kg of resin per Kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Sqm229.9229.9926.0FalseNoneNoneFalseNoneFalse212887.40
296146597889NoneBOQ129Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc.all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.Sqm3137.23137.288.8FalseNoneNoneFalseNoneFalse278583.360
296146697889NoneBOQ130b) First floorMtr3168.573168.5788.8FalseNoneNoneFalseNoneFalse281369.0160
296146797889NoneBOQ131c) Second FloorMtr3199.943199.9488.8FalseNoneNoneFalseNoneFalse284154.6720
296146897889NoneBOQ132Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1593.91593.9106.0FalseNoneNoneFalseNoneFalse168953.40
296146997889NoneBOQ133b) First floorSqm1609.831609.83106.0FalseNoneNoneFalseNoneFalse170641.980
296147097889NoneBOQ134c) Second FloorSqm1625.771625.77106.0FalseNoneNoneFalseNoneFalse172331.620
296147197889NoneBOQ135Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-charge.Mtr360.8360.85.0FalseNoneNoneFalseNoneFalse1804.00
296147297889NoneBOQ136Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc.all complete as per the direction of Engineer-in-charge.Sqm880.0880.0151.0FalseNoneNoneFalseNoneFalse132880.00
296147397889NoneBOQ137Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering.Sqm306.9306.9828.0FalseNoneNoneFalseNoneFalse254113.20
296147497889NoneBOQ138b) First floorSqm309.96309.96784.0FalseNoneNoneFalseNoneFalse243008.640
296147597889NoneBOQ139c) Second FloorSqm313.03313.03784.0FalseNoneNoneFalseNoneFalse245415.520
296147697889NoneBOQ140d)Terrace FloorSqm316.1316.160.0FalseNoneNoneFalseNoneFalse18966.00
296147797889NoneBOQ141Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering.Sqm383.9383.978.0FalseNoneNoneFalseNoneFalse29944.20
296147897889NoneBOQ142b) First floorSqm387.73387.7397.0FalseNoneNoneFalseNoneFalse37609.810
296147997889NoneBOQ143c) Second FloorSqm391.57391.57104.0FalseNoneNoneFalseNoneFalse40723.280
296148097889NoneBOQ144Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering.Sqm355.3355.3318.0FalseNoneNoneFalseNoneFalse112985.40
296148197889NoneBOQ145b) First floorSqm358.85358.85318.0FalseNoneNoneFalseNoneFalse114114.30
296148297889NoneBOQ146c) Second FloorSqm362.4362.4318.0FalseNoneNoneFalseNoneFalse115243.20
296148397889NoneBOQ147d)Terrace FloorSqm365.95365.9515.0FalseNoneNoneFalseNoneFalse5489.250
296148497889NoneBOQ148Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External PlasteringSqm423.5423.5276.0FalseNoneNoneFalseNoneFalse116886.00
296148597889NoneBOQ149b) First floorSqm427.73427.73276.0FalseNoneNoneFalseNoneFalse118053.480
296148697889NoneBOQ150c) Second FloorSqm431.96431.96276.0FalseNoneNoneFalseNoneFalse119220.960
296148797889NoneBOQ151Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the Engineer-in-Charge.Sqm63.863.8276.0FalseNoneNoneFalseNoneFalse17608.80
296148897889NoneBOQ152b) First floorSqm64.4364.43276.0FalseNoneNoneFalseNoneFalse17782.680
296148997889NoneBOQ153c) Second FloorSqm65.0765.07276.0FalseNoneNoneFalseNoneFalse17959.320
296149097889NoneBOQ154Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/Sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications.( length of mesh only be measured for payment. Plaster mesh 100mm wideMtr48.448.41200.0FalseNoneNoneFalseNoneFalse58080.00
296149197889NoneBOQ155b) First floorMtr48.848.81200.0FalseNoneNoneFalseNoneFalse58560.00
296149297889NoneBOQ156c) Second FloorMtr49.3649.361200.0FalseNoneNoneFalseNoneFalse59232.00
296149397889NoneBOQ157d)Terrace FloorMtr49.8549.85140.0FalseNoneNoneFalseNoneFalse6979.00
296149497889NoneBOQ158Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Mtr110.0110.01146.0FalseNoneNoneFalseNoneFalse126060.00
296149597889NoneBOQ159b) First floorMtr111.1111.11146.0FalseNoneNoneFalseNoneFalse127320.60
296149697889NoneBOQ160c) Second FloorMtr112.2112.2318.0FalseNoneNoneFalseNoneFalse35679.60
296149797889NoneBOQ161d)Terrace FloorMtr113.3113.366.0FalseNoneNoneFalseNoneFalse7477.80
296149897889NoneBOQ162Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.Sqm58.358.31146.0FalseNoneNoneFalseNoneFalse66811.80
296149997889NoneBOQ163b) First floorSqm58.8858.881146.0FalseNoneNoneFalseNoneFalse67476.480
296150097889NoneBOQ164c) Second FloorSqm59.4659.46318.0FalseNoneNoneFalseNoneFalse18908.280
296150197889NoneBOQ165d)Terrace FloorSqm60.0460.0466.0FalseNoneNoneFalseNoneFalse3962.640
296150297889NoneBOQ166Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.Two coats as per specifications and as per directions of Engineer in charge.Sqm121.0121.01146.0FalseNoneNoneFalseNoneFalse138666.00
296150397889NoneBOQ167b) First floorSqm122.21122.211146.0FalseNoneNoneFalseNoneFalse140052.660
296150497889NoneBOQ168c) Second FloorSqm123.42123.421146.0FalseNoneNoneFalseNoneFalse141439.320
296150597889NoneBOQ169d)Terrace FloorSqm124.63124.6360.0FalseNoneNoneFalseNoneFalse7477.80
296150697889NoneBOQ170Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 Kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm191.4191.4276.0FalseNoneNoneFalseNoneFalse52826.40
296150797889NoneBOQ171b) First floorSqm193.31193.31276.0FalseNoneNoneFalseNoneFalse53353.560
296150897889NoneBOQ172c) Second FloorSqm195.22195.22276.0FalseNoneNoneFalseNoneFalse53880.720
296150997889NoneBOQ173d)Terrace FloorSqm197.14197.14125.0FalseNoneNoneFalseNoneFalse24642.50
296151097889NoneBOQ174Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm183.7183.7150.0FalseNoneNoneFalseNoneFalse27555.00
296151197889NoneBOQ175Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge.The IGUs shall be assembled in the factory/workshop of the glass processor.(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item Nos18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25-0.28) and U value of 3.0 to 3.3 W/Sqm degree K etc.The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.Sqm3347.33347.320.0FalseNoneNoneFalseNoneFalse66946.00
296151297889NoneBOQ176Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III).The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick.The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings.The complete system to be designed to accommodate hermal expansion & seismic movements etc.The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc.all complete.For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.Sqm8747.28747.212.0FalseNoneNoneFalseNoneFalse104966.40
296151397889NoneBOQ177Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6290.96290.922.0FalseNoneNoneFalseNoneFalse138399.80
296151497889NoneBOQ178Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc.,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge.For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in Sqm.(Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item).(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/Sqm K etc..The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement.Sqm2178.02178.04.0FalseNoneNoneFalseNoneFalse8712.00
296151597889NoneBOQ179Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent.The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm.The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint.The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight portionSqm4387.94387.914.0FalseNoneNoneFalseNoneFalse61430.60
296151697889NoneBOQ180Providing, fabricating and fixing of 6 mm thick High Pressure Laminate sheets in standard size of 1200 mm x 2400 mm (Sheets can be supplied in customized length depending on requirement).Sheets shall be manufactured involving a series of mechanical process in a state-of-the-art facility shall comprise of 0.25 mm Aluminium skins on both sides sandwiching an LDPE (Low Density Poly Ethylene) core having a density of 0.92 g/cCum giving the overall weight of HPL at 7.8 Kg/Sqm.Aluminium skins to have a desired lacquer in Lumiflon coated on one side/Both side.The supplied panels shall have a dexterity to be formed in convex and concave shapes as also the ability to bend in 90 degrees under a mechanical process.Panel will be installed on Aluminium tubes at 500 mm c/c distance with special L brackets.There will be special fixing treatment on all the corner sections.Aluminium tube size will be 25 mm x 50 mm.Boards will be fixed on the Aluminium channels with colour matched rivets/ MS polymer Adhesives and brackets through 8 mm drill hole in boards and 5 mm dia drill holes in aluminium box.Rivets will be installed by automatic rivet guns / adhesive should be used with proper silicone extrusion gun and properly laid over panel and aluminium tube on every 500mm gap as per direction of Engineer in charge.Wooden textured Colored sheets-Single sidedSqm3434.23434.222.0FalseNoneNoneFalseNoneFalse75552.40
296151797889NoneBOQ181Providing and fabricating lacquered glass formed using Aluminium frame work at 600mm c/c.The frame work shall be clad with 8mm thick lacquered glass with 12mm thick MDF /ply backing, complete as per detailed drawing and instructions of the Architect.MRSqm7500.07500.010.0FalseNoneNoneFalseNoneFalse75000.00
296151897889NoneBOQ182Providing & fixing veneer panelling, over the 50mm x 35mm sal wood frame work at spacing not exceeding 600mm c/c fixed to the wall and top covered out of 4mm thick approved quality veneer, fixed over 12mm thick ply of approved brand, termite and water resitantfinished with melaminepolish, complete includingcost and conveyance of all materials, labour for all items of work HOM etc., complete as per specificationSqm3739.03739.024.0FalseNoneNoneFalseNoneFalse89736.00
296151997889NoneBOQ183Providing, fabricating and fixing of 10 mm thick Decorative Grooved Bamboo Wood Wall cladding with panel size 1220mmx2440mm, thermal insulation value 2.2 J/g oC & having density 1300Kg/Cum.The base material shall be of MDF and the surface of Bamboo shall be coated with Graphene based PU Coating.The material shall possess special properties such as Fire resistant, Thermal insulation, Sound absorbent and UV & Water resistant.The panel shall be fixed on walls using Mild steel screws or by using special adhesives as per direction of Engineer in charge.Sqm2227.52227.547.0FalseNoneNoneFalseNoneFalse104692.50
296152097889NoneBOQ184Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 g/Sqm, both side inclusive) consisting of main ""T"" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross ""T"" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main ""T"" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross ""T"" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main ""T"" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GIadjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing.Sqm1288.11288.157.0FalseNoneNoneFalseNoneFalse73421.70
296152197889NoneBOQ185b) First floorSqm1300.981300.9812.0FalseNoneNoneFalseNoneFalse15611.760
296152297889NoneBOQ186c) Second FloorSqm1313.861313.8634.0FalseNoneNoneFalseNoneFalse44671.240
296152397889NoneBOQ187Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms/Sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I.channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm Each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS Certification marks only)Sqm1081.31081.323.0FalseNoneNoneFalseNoneFalse24869.90
296152497889NoneBOQ188b) First floorSqm1092.111092.113.0FalseNoneNoneFalseNoneFalse3276.330
296152597889NoneBOQ189c) Second FloorSqm1102.921102.9213.0FalseNoneNoneFalseNoneFalse14337.960
296152697889NoneBOQ190Providing and fixing VOX Soffit Infratop false ceiling SV 08, panel sizes of 300mmx2700mm , durable and resistant to moisture, water proof and free from borer-fungus-termite attack, thermal printing technology imitating closer finish to wood, click system for interlocking etc including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. MRSqm3600.03600.012.0FalseNoneNoneFalseNoneFalse43200.00
296152797889NoneBOQ191Providing and fixing CUBICLE WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA powder coated,tile based system for main and return spine, Top tile finish 8 mm thick MDF covered with Fabric of approved colour and one writing board (600 mm W) and one soft board (600 mm W) per workstation, Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway- one middle raceway (600mm W) below table top per workstation and continous raceway at the skirting level, Wire manager -ABS plastic grommet one number per table, Table top - 25 mm thick PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound Hardware-MS powder coated corner bid, cantilever bkt, seperator hook on bkt, L bkt and Table joint plate., as per specifications, drawings and as directed by Engineer in charge.X type 4 wings 1500mmW x 1500mmD 1200mmHNos55000.055000.03.0FalseNoneNoneFalseNoneFalse165000.00
296152897889NoneBOQ192Supplying Black Medium Back Mesh chair of size 585mm(L)x585mm(W)x1040mm(H) with cushion seat and mesh back with cushion arms and nylon base with Pnuematic height adjustable system with wheel rollers complete as per specification.Make: Featherlite/Equivalent MRNos7500.07500.020.0FalseNoneNoneFalseNoneFalse150000.00
296152997889NoneBOQ193Supplying Black Low Back Mesh chair of size 485mm(L)x485mm(W)x1040mm(H) with cushion seat and mesh back with cushion arms and nylon base with Pnuematic height adjustable system with wheel rollers complete as per specification. Make: Featherlite/Equivalent MRNos5500.05500.016.0FalseNoneNoneFalseNoneFalse88000.00
296153097889NoneBOQ194Providing and fixing free standing table for cabin -without frames consisting of 25 mm thick PLPB table top, 25mm thick PLPB with edge bomded end table, 18mm thick PLPB with edge bonded modesty wire manager - ABS plastic grommet one number per table hardware - minfix assembly and screw leg., as per specifications, drawings and as directed by engineer in charge.Main table 2000mmW x750mmD x 750mmH top) Side Table : 900 mm W x 450mm DX 750 mm ht.Nos25000.025000.01.0FalseNoneNoneFalseNoneFalse25000.00
296153197889NoneBOQ195Providing and fixing free standing table for cabin -without frames consisting of 25 mm thick PLPB table top, 25mm thick PLPB with edge bomded end table, 18mm thick PLPB with edge bonded modesty wire manager - ABS plastic grommet one number per table hardware - minfix assembly and screw leg., as per specifications, drawings and as directed by engineer in charge.Main table 1800mmW x750mmD x 750mmH top) Side Table : 900 mm W x 450mm DX 750 mm ht.Nos22000.022000.05.0FalseNoneNoneFalseNoneFalse110000.00
296153297889NoneBOQ196Providing and fixing free standing table for cabin -without frames consisting of 25 mm thick PLPB table top, 25mm thick PLPB with edge bomded end table, 18mm thick PLPB with edge bonded modesty wire manager - ABS plastic grommet one number per table hardware - minfix assembly and screw leg., as per specifications, drawings and as directed by engineer in charge.Main table 1500mmW x750mmD x 750mmH top) Side Table : 900 mm W x 450mm DX 750 mm ht.Nos20000.020000.04.0FalseNoneNoneFalseNoneFalse80000.00
296153397889NoneBOQ197Supplying Liberate High Back Mesh chair of size 660mm(L)x660mm(W)x1250mm(H) with cushion seat and mesh back with cushion arms and chrome plated metal base with Pnuematic height adjustable system with wheel rollers complete as per specification.Make: Featherlite/EquivalentNos18000.018000.03.0FalseNoneNoneFalseNoneFalse54000.00
296153497889NoneBOQ198Providing and fixing 450mmw X 450 mmd X 685 mmht) Mobile pedestal unit - WOODEN with 18mm thick PLPB with edge bonded for body, Two equal drawer and one filing drawer with centralized locking system, Telescopic channels, castors, Handles and lock etc., MRNos5000.05000.020.0FalseNoneNoneFalseNoneFalse100000.00
296153597889NoneBOQ199Wardrobe Providing and fixing wardrobe with 19 mm thick block board with shutters and shelves,.8mm inside & 1.2 mm outside laminate/veneer of approved make on all exposed surfaces including necessary hardware , locks etc.edge painting , polishing etc.complete as per drawings.MRSqm11000.011000.018.0FalseNoneNoneFalseNoneFalse198000.00
296153697889NoneBOQ200Providing and fixing Reception Table In Brown -1 Drawer + 1 shutter unit - The PLPB (Wood Base) of Grade II.Nos25000.025000.01.0FalseNoneNoneFalseNoneFalse25000.00
296153797889NoneBOQ201Providing and fixing Self adhesive wall paper for cabin - Peel and stick vinyl wall paperSqm400.0400.024.0FalseNoneNoneFalseNoneFalse9600.00
296153897889NoneBOQ202Providing and fixing Record room Racks of following specification.Total Nosof Racks of size 2100mm H X 1300mm W X 450mm D with 3 compartment, Capacity of Flat Files considering 25mm thickness-16000 files (OR) Capacity of Box Files considering 90mm thickness-4480 files, Epoxy Powder Coated Finish, Load Bearing Capacity per Shelf (UDL): 150 Kgs. Single Faced Fixed(A) (5mx0.38mx2.1m)Nos98000.098000.01.0FalseNoneNoneFalseNoneFalse98000.00
296153997889NoneBOQ203Double Faced Movable (B) (5mx0.76mx2.1m)Nos175000.0175000.02.0FalseNoneNoneFalseNoneFalse350000.00
296154097889NoneBOQ204Single Faced Movable (C ) (5mx0.45mx2.1m)Nos108000.0108000.01.0FalseNoneNoneFalseNoneFalse108000.00
296154197889NoneBOQ205Providing and fixing storage unit of approved size & 450mm depth made out of 19mm thick commercial ply finished in approved 1.00mm laminate on both external & internal faces of approved colour and shade.Shelves shall be formed out of 19mm ply finished with 1.00mm laminate of approved shade and colour and 19mm thick shutters formed out of 19mm thick ply finished with 1.00mm thick laminate of approved shade and colour etc., complete the rate includes cost of all materials, labour charges, complete as per specification including necessary hardwares & fittings.MRSqm15000.015000.07.0FalseNoneNoneFalseNoneFalse105000.00
296154297889NoneBOQ206Providing & fixing Roller Blinds of reputed make 38mm round Aluminium channel with blackout fabric, telting with chain (Ball) system with all necessary fittings and fixtures as per direction of Engineer in chargeSqm1980.01980.060.0FalseNoneNoneFalseNoneFalse118800.00
296154397889NoneBOQ207Providing and fixing directional signage as per the approved design Size - 1'6" x 6" MRNos1500.01500.020.0FalseNoneNoneFalseNoneFalse30000.00
296154497889NoneBOQ208Supply and fixing privacy film on the glass partition MRSqm1750.01750.032.0FalseNoneNoneFalseNoneFalse56000.00
296154597889NoneBOQ209Providing and fixing Three seater Sofa with cushion of size 7(L)x2.5(W) X2.75(H) ft made of upholstery fabric with seats fitted with padding, springs, webbing and as per direction of engineer in chargeNos41250.041250.02.0FalseNoneNoneFalseNoneFalse82500.00
296154697889NoneBOQ210Providing and fixing Waiting Area Chair / 3 Seater Visitor Reception Heavy Chair in Chrome Finish (Stainless Steel)Nos25000.025000.02.0FalseNoneNoneFalseNoneFalse50000.00
296154797889NoneBOQ211Providing and Fixing Hollow acrylic letters or logos which are approximately three inches thick.LEDs are embedded in the hollow space beneath these letters.These 3D letters and logos are mounted on an ACP box frame.This aluminium frame, along with the backlit acrylic letters, are then installed on-site.complete as per specification and instructions of the Architect. Letters of BESCOM External logos.MRNos35000.035000.02.0FalseNoneNoneFalseNoneFalse70000.00
296154897889NoneBOQ212Providing and Fixing Hollow acrylic letters or logos which are approximately three inches thick.LEDs are embedded in the hollow space beneath these letters.These 3D letters and logos are mounted on an ACP box frame.This aluminium frame, along with the backlit acrylic letters, are then installed on-site.complete as per specification and instructions of the Architect. Letters of BESCOM logosMRNos25000.025000.01.0FalseNoneNoneFalseNoneFalse25000.00
296154997889NoneBOQ213Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C.top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) With common burnt clay (non modular) bricks of class designation 3.5Each11622.611622.64.0FalseNoneNoneFalseNoneFalse46490.40
296155097889NoneBOQ214Providing and fixing wash basin with C.I.brackets, 15 mm C.P.brass pillar taps, 32 mm C.P.brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P.brass pillar tapsNos3152.63152.617.0FalseNoneNoneFalseNoneFalse53594.20
296155197889NoneBOQ215Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.Nos12346.412346.413.0FalseNoneNoneFalseNoneFalse160503.20
296155297889NoneBOQ216Providing and fixing Bidet spray made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class PremiumNos1122.01122.05.0FalseNoneNoneFalseNoneFalse5610.00
296155397889NoneBOQ217Providing and fixing C.P.brass bib cock of approved quality conforming to IS:8931Nos698.5698.530.0FalseNoneNoneFalseNoneFalse20955.00
296155497889NoneBOQ218Providing and fixing C.P.brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.Nos797.5797.530.0FalseNoneNoneFalseNoneFalse23925.00
296155597889NoneBOQ219Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P.brass screws and washers complete.Nos1342.01342.06.0FalseNoneNoneFalseNoneFalse8052.00
296155697889NoneBOQ220Providing and fixing Soap dish wired with 200mm width made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class PremiumNos2333.12333.18.0FalseNoneNoneFalseNoneFalse18664.80
296155797889NoneBOQ221Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class PremiumNos4196.54196.56.0FalseNoneNoneFalseNoneFalse25179.00
296155897889NoneBOQ222Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I.brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mmNos6179.86179.82.0FalseNoneNoneFalseNoneFalse12359.60
296155997889NoneBOQ223Providing and fixing Pillar Cock made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class PremiumNos2876.52876.520.0FalseNoneNoneFalseNoneFalse57530.00
296156097889NoneBOQ224Providing and fixing Angle cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accessories complete - Class PremiumNos2109.82109.830.0FalseNoneNoneFalseNoneFalse63294.00
296156197889NoneBOQ225Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P.brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre white P.V.C.automatic flushing cisternNos4899.44899.46.0FalseNoneNoneFalseNoneFalse29396.40
296156297889NoneBOQ226Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.Concealed work, including cutting chases and making good the walls etc.20 mm dia pipe nominal OD pipesMtr416.9416.9195.0FalseNoneNoneFalseNoneFalse81295.50
296156397889NoneBOQ227CPVC 25 mm dia pipe nominal OD pipesMtr524.7524.72.0FalseNoneNoneFalseNoneFalse1049.40
296156497889NoneBOQ228Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal boreNos345.4345.41.0FalseNoneNoneFalseNoneFalse345.40
296156597889NoneBOQ229Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 25 mm nominal boreNos603.9603.94.0FalseNoneNoneFalseNoneFalse2415.60
296156697889NoneBOQ230Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 32 mm nominal boreNos657.8657.81.0FalseNoneNoneFalseNoneFalse657.80
296156797889NoneBOQ231Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 40 mm nominal boreNos772.2772.21.0FalseNoneNoneFalseNoneFalse772.20
296156897889NoneBOQ232Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) : 50 mm nominal boreNos940.5940.525.0FalseNoneNoneFalseNoneFalse23512.50
296156997889NoneBOQ233Providing and fixing P.V.C.waste pipe for sink or wash basin including P.V.C.waste fittings complete.Semi rigid pipe 40 mm diaNos96.896.820.0FalseNoneNoneFalseNoneFalse1936.00
296157097889NoneBOQ234Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms.with soft gravel or selected earth available from the excavation etc.complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.for: PVC pipes 75mm dia., 6 Kg/sqcm & class 3Mtr220.0220.095.0FalseNoneNoneFalseNoneFalse20900.00
296157197889NoneBOQ235Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 75mm dia PVC couplersNos67.067.01.0FalseNoneNoneFalseNoneFalse67.00
296157297889NoneBOQ236Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC ElbowsNos192.0192.01.0FalseNoneNoneFalseNoneFalse192.00
296157397889NoneBOQ237Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 75 mm dia PVC teeNos117.0117.02.0FalseNoneNoneFalseNoneFalse234.00
296157497889NoneBOQ238Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms.with soft gravel or selected earth available from the excavation etc.complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.for: PVC pipes 110mm dia., 6 Kg/sqcm & class 3Mtr411.0411.0125.0FalseNoneNoneFalseNoneFalse51375.00
296157597889NoneBOQ239Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete 110mm dia PVC couplersNos171.0171.08.0FalseNoneNoneFalseNoneFalse1368.00
296157697889NoneBOQ240Supplying of special moulded variety PVC Elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete 110mm dia PVC ElbowsNos302.0302.08.0FalseNoneNoneFalseNoneFalse2416.00
296157797889NoneBOQ241Supplying of special moulded variety PVC Tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc.complete 110mm dia PVC TeeNos251.0251.012.0FalseNoneNoneFalseNoneFalse3012.00
296157897889NoneBOQ242Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X 4.0 cm with all fitting arrangements & all necessary accessories completeNos268.4268.422.0FalseNoneNoneFalseNoneFalse5904.80
296157997889NoneBOQ243Providing and fixing PVC (S.W.R) P Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNos339.9339.916.0FalseNoneNoneFalseNoneFalse5438.40
296158097889NoneBOQ244Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNos380.6380.68.0FalseNoneNoneFalseNoneFalse3044.80
296158197889NoneBOQ245Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeNos242.0242.08.0FalseNoneNoneFalseNoneFalse1936.00
296158297889NoneBOQ246Supply and installation of solar heater on terrace, Non-pressurized solar heater capacity of 200 litre/day, heat reservation around 72hrs, 2kw Electric capacity. ( Tata Bp Solar Water Heater )Nos40000.040000.01.0FalseNoneNoneFalseNoneFalse40000.00
296158397889NoneBOQ247Providing and fixing Brass full way valve gate with C.I.wheel of approved quality (screwed end) 25 mm nominal boreNos603.9603.96.0FalseNoneNoneFalseNoneFalse3623.40
296158497889NoneBOQ248Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.External work 20 mm nominal dia PipesMtr238.7238.7195.0FalseNoneNoneFalseNoneFalse46546.50
296158597889NoneBOQ249CPVC 25 mm dia pipe nominal OD pipesMtr325.6325.6160.0FalseNoneNoneFalseNoneFalse52096.00
296158697889NoneBOQ250CPVC 32 mm dia pipe nominal OD pipesMtr409.2409.2178.0FalseNoneNoneFalseNoneFalse72837.60
296158797889NoneBOQ251CPVC 40 mm dia pipe nominal OD pipesMtr524.7524.780.0FalseNoneNoneFalseNoneFalse41976.00
296158897889NoneBOQ252CPVC 50 mm dia pipe nominal OD pipesMtr793.1793.190.0FalseNoneNoneFalseNoneFalse71379.00
296158997889NoneBOQ253Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tankLtr9.99.94000.0FalseNoneNoneFalseNoneFalse39600.00
296159097889NoneBOQ254Providing and fixing of PVC Rungs footrest in under ground tanks/ manhole using Sqm0 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materias, labour, curing etccomplete as per specificationMRNos345.0345.010.0FalseNoneNoneFalseNoneFalse3450.00
296159197889NoneBOQ255Supplying, fixing, testing and commisioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square ) as per approved design.The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified 150 x 150 mm PVC gratingMRNos955.0955.02.0FalseNoneNoneFalseNoneFalse1910.00
296159297889NoneBOQ256Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 100 mm diameter Vol 2 Pg Nos125 S.Nos13.48Mtr320.1320.125.0FalseNoneNoneFalseNoneFalse8002.50
296159397889NoneBOQ257Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc.excluding the cost of CI frame and cover.Nos5454.05454.02.0FalseNoneNoneFalseNoneFalse10908.00
296159497889NoneBOQ258Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc.in layers not exceeding 20cm in depth, consolidating Each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils.Depth upto 1.50mMtr532.4532.435.0FalseNoneNoneFalseNoneFalse18634.00
296159597889NoneBOQ259Supplying, installing, testing and commissioning of submersible electrical driven pump 1set.to lift domestic water with all necessary arrangements to operate on 1HP Single Phase fitted on a common base frame accessories to lift the pump during maintenance, control panel with wiring from TPN switch to control panel and to the pump and the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc., complete as complete.(MR) Duty of the Pump two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.Nos27600.027600.01.0FalseNoneNoneFalseNoneFalse27600.00
296159697889NoneBOQ260Providing and fixing gun metal non- return valve of approved quality (screwed end) :32 mm nominal bore verticalNos764.5764.52.0FalseNoneNoneFalseNoneFalse1529.00
296159797889NoneBOQ261Providing and fixing gun metal non- return valve of approved quality (screwed end) :40 mm nominal bore verticalNos1347.51347.52.0FalseNoneNoneFalseNoneFalse2695.00
296159897889NoneBOQ262Supply and fixing 600mm puddle flange consisting of 6mm thick welded MS plate, flanges of suitable size properly fixed in walls of water tanks as per specifications and approved drawings of following diameters 32 mm diaMRNos800.0800.04.0FalseNoneNoneFalseNoneFalse3200.00
296159997889NoneBOQ263b.40 mm diaMRNos952.0952.04.0FalseNoneNoneFalseNoneFalse3808.00
296160097889NoneBOQ264c.50 mm diaMRNos1200.01200.04.0FalseNoneNoneFalseNoneFalse4800.00
296160197889NoneBOQ265Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc.The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor.The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration.3 Nos.bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually.Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration.Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge.Each30000.030000.04.0FalseNoneNoneFalseNoneFalse120000.00
296160297889NoneBOQ266Open Conduit System Supplying heavy gauge PVC conduit pipe.......dia.......mm thick confirming to IS2509 with suitable size bends, junctionboxes, adhesivepasteetc, and fixing using inverted woodplugs incase of RCC ceiling and RCCwall/stone structure or rawlplugs incase of brickwalls and cement plastering the damaged portion using heavygauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thickMtr75.975.9250.0FalseNoneNoneFalseNoneFalse18975.00
296160397889NoneBOQ267b.25 mm dia 2 mm thickMtr89.189.1100.0FalseNoneNoneFalseNoneFalse8910.00
296160497889NoneBOQ268c.32 mm dia 2.5 mm thickMtr116.6116.675.0FalseNoneNoneFalseNoneFalse8745.00
296160597889NoneBOQ269Concealed Conduit System Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thickMtr72.672.6750.0FalseNoneNoneFalseNoneFalse54450.00
296160697889NoneBOQ270b.25 mm dia 2 mm thickMtr85.885.8250.0FalseNoneNoneFalseNoneFalse21450.00
296160797889NoneBOQ271c.32 mm dia 2.5 mm thickMtr113.3113.3250.0FalseNoneNoneFalseNoneFalse28325.00
296160897889NoneBOQ272Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing UorJ hooks and cement plastering upto the wall surface and run with 18SWG GIfishwire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thickMtr74.874.8100.0FalseNoneNoneFalseNoneFalse7480.00
296160997889NoneBOQ273b.25 mm dia 2 mm thickMtr86.986.9250.0FalseNoneNoneFalseNoneFalse21725.00
296161097889NoneBOQ274c.32 mm dia 2.5 mm thickMtr108.9108.930.0FalseNoneNoneFalseNoneFalse3267.00
296161197889NoneBOQ275Supplying and fixing PVC/metal conduit Deep junction box 19/20 mm deep Junction boxNos53.953.960.0FalseNoneNoneFalseNoneFalse3234.00
296161297889NoneBOQ276b.25 mm deep Junction boxNos61.661.6180.0FalseNoneNoneFalseNoneFalse11088.00
296161397889NoneBOQ277c.32 mm deep Junction boxNos67.167.130.0FalseNoneNoneFalseNoneFalse2013.00
296161497889NoneBOQ278Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing upto wall surface complete.upto 50 mm conduit CC floorMtr75.975.960.0FalseNoneNoneFalseNoneFalse4554.00
296161597889NoneBOQ279Supplying And Fixing Metal Fan Box with Round Hook.S HOK M.S.Rod.Nos128.7128.735.0FalseNoneNoneFalseNoneFalse4504.50
296161697889NoneBOQ280Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mSqm (Phase & Neutral) & 1x1.0 mSqm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for Each outlet.. Short point upto 3m from tapping point to out let via switch boxPoint295.9295.960.0FalseNoneNoneFalseNoneFalse17754.00
296161797889NoneBOQ281Medium point above 3m upto 6m from tapping point to out let via switch boxPoint416.9416.960.0FalseNoneNoneFalseNoneFalse25014.00
296161897889NoneBOQ282Long point above 6m upto 10m from tapping point to out let via switch boxPoint610.5610.540.0FalseNoneNoneFalseNoneFalse24420.00
296161997889NoneBOQ283Two outlet in a row, above 3m upto 6m from tapping point to out let via switchesPoint744.7744.750.0FalseNoneNoneFalseNoneFalse37235.00
296162097889NoneBOQ284Three outlet in a row, above 6m upto 10m from tapping point to out let via switches boxPoint1087.91087.910.0FalseNoneNoneFalseNoneFalse10879.00
296162197889NoneBOQ285Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mSqmMtr28.628.6990.0FalseNoneNoneFalseNoneFalse28314.00
296162297889NoneBOQ286b.2.5 mSqmMtr46.246.22500.0FalseNoneNoneFalseNoneFalse115500.00
296162397889NoneBOQ287c.4 mSqmMtr69.369.31750.0FalseNoneNoneFalseNoneFalse121275.00
296162497889NoneBOQ288d.6 mSqmMtr101.2101.2800.0FalseNoneNoneFalseNoneFalse80960.00
296162597889NoneBOQ289e.10 mSqmMtr183.7183.7200.0FalseNoneNoneFalseNoneFalse36740.00
296162697889NoneBOQ290Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall. 1-2 WayNos151.8151.8150.0FalseNoneNoneFalseNoneFalse22770.00
296162797889NoneBOQ291b.3 WayNos174.9174.930.0FalseNoneNoneFalseNoneFalse5247.00
296162897889NoneBOQ292c.4-5 WayNos194.7194.720.0FalseNoneNoneFalseNoneFalse3894.00
296162997889NoneBOQ293d.6 WayNos242.0242.075.0FalseNoneNoneFalseNoneFalse18150.00
296163097889NoneBOQ294e.8 WayNos287.1287.160.0FalseNoneNoneFalseNoneFalse17226.00
296163197889NoneBOQ295f.10-12 WayNos350.9350.915.0FalseNoneNoneFalseNoneFalse5263.50
296163297889NoneBOQ296Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleNos150.7150.7150.0FalseNoneNoneFalseNoneFalse22605.00
296163397889NoneBOQ297b.3 ModuleNos177.1177.130.0FalseNoneNoneFalseNoneFalse5313.00
296163497889NoneBOQ298c.4 ModuleNos192.5192.520.0FalseNoneNoneFalseNoneFalse3850.00
296163597889NoneBOQ299d.6 ModuleNos257.4257.475.0FalseNoneNoneFalseNoneFalse19305.00
296163697889NoneBOQ300e.8 ModuleNos312.4312.412.0FalseNoneNoneFalseNoneFalse3748.80
296163797889NoneBOQ301f.10-12 ModuleNos378.4378.412.0FalseNoneNoneFalseNoneFalse4540.80
296163897889NoneBOQ302Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way SwitchNos112.2112.2350.0FalseNoneNoneFalseNoneFalse39270.00
296163997889NoneBOQ303b.6A Two Way SwitchNos182.6182.66.0FalseNoneNoneFalseNoneFalse1095.60
296164097889NoneBOQ304c.6A Three Way socketNos188.1188.1230.0FalseNoneNoneFalseNoneFalse43263.00
296164197889NoneBOQ305Stepped Fan Regulator Two ModuleNos392.7392.720.0FalseNoneNoneFalseNoneFalse7854.00
296164297889NoneBOQ306Providing 16A One Way SwitchNos198.0198.030.0FalseNoneNoneFalseNoneFalse5940.00
296164397889NoneBOQ307Providing 32A DP SwitchNos358.6358.610.0FalseNoneNoneFalseNoneFalse3586.00
296164497889NoneBOQ308Providing 6/16A Universal SocketNos259.6259.634.0FalseNoneNoneFalseNoneFalse8826.40
296164597889NoneBOQ309TV/Telephone Socket.Nos171.6171.621.0FalseNoneNoneFalseNoneFalse3603.60
296164697889NoneBOQ310Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC61439-3 and IK09 Tested as per IS/IEC62262 with minimum IP43 protection provided with Polyurethane(PUR)gasket,with suitable earthing system, on wall/wood board/flush mounting using required clA,bolts,nuts,etc.,with provision for fixing of suitable type capacity MCCB's as an incomer for 3phase Doubledoor with necessary bus bar completely wired touseon 440V3 phase4 wire powder coated painting etc.,complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 4 WAYNos11361.911361.92.0FalseNoneNoneFalseNoneFalse22723.80
296164797889NoneBOQ311b.8 WAYNos13865.513865.51.0FalseNoneNoneFalseNoneFalse13865.50
296164897889NoneBOQ312c.12 WAYNos17081.917081.91.0FalseNoneNoneFalseNoneFalse17081.90
296164997889NoneBOQ313Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. Single door 16 Way SP & NNos3225.23225.22.0FalseNoneNoneFalseNoneFalse6450.40
296165097889NoneBOQ314Double Door 8 Way SP & NNos2039.42039.43.0FalseNoneNoneFalseNoneFalse6118.20
296165197889NoneBOQ315Double Door 12 Way SP & NNos2561.92561.95.0FalseNoneNoneFalseNoneFalse12809.50
296165297889NoneBOQ316Supplying, fixing and wiring earth electrode for grounding of DG sets etc using 40 mm dia 2.9 mm thick2.5mtr long G.I pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm have staggered holes of 12mm dia and the electrode should be covered 150mm all round with alternate layers of salt and charcoal from the bottom of the CC chamber.Nos4772.04772.04.0FalseNoneNoneFalseNoneFalse19088.00
296165397889NoneBOQ317Supplying and running of GI / copper strips for grounding connections using necessary fixing materials as required GI Strips - 25 x 3 mmMtr86.086.0125.0FalseNoneNoneFalseNoneFalse10750.00
296165497889NoneBOQ318Providing 8 SWG GI WireMtr22.022.075.0FalseNoneNoneFalseNoneFalse1650.00
296165597889NoneBOQ319Supplying and installation of 1.1 KV LT UG cable XLPE or heat resistant PVC insulated , PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS - 7098 part -1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS - 3975. 3.5 core 50 sqmmKm236247.94236247.940.1FalseNoneNoneFalseNoneFalse23624.7940
296165697889NoneBOQ320Laying of cable in existing trench /GI pipe/ stone ware/RCC Hume pipe using Wooden/ Auminum Rollers. 2.5 sqmm to 25 sqmmMtr15748.015748.00.25FalseNoneNoneFalseNoneFalse3937.00
296165797889NoneBOQ321b.35 sqmm to 95 sqmmMtr23044.023044.00.15FalseNoneNoneFalseNoneFalse3456.60
296165897889NoneBOQ322Supplying and fixing of heavy duty cable glands suitable for UG cable off 1.1 KV class (metal only). 19/20/25 mmMtr75.075.012.0FalseNoneNoneFalseNoneFalse900.00
296165997889NoneBOQ323b.32 mmMtr90.090.04.0FalseNoneNoneFalseNoneFalse360.00
296166097889NoneBOQ324Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC SupplyNos1641.21641.220.0FalseNoneNoneFalseNoneFalse32824.00
296166197889NoneBOQ325Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding.Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.48" Sweep 5 Star (1200 mm)Nos2944.72944.735.0FalseNoneNoneFalseNoneFalse103064.50
296166297889NoneBOQ326Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires.Nos217.8217.810.0FalseNoneNoneFalseNoneFalse2178.00
296166397889NoneBOQ327Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / GirdersNos134.2134.2270.0FalseNoneNoneFalseNoneFalse36234.00
296166497889NoneBOQ328Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A.ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.Nos346.5346.535.0FalseNoneNoneFalseNoneFalse12127.50
296166597889NoneBOQ329Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A.ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Nos541.2541.220.0FalseNoneNoneFalseNoneFalse10824.00
296166697889NoneBOQ330Supply of 15 W LED bulk head fitting with guard, Acrylic glass and suitable driverMRNos1680.01680.015.0FalseNoneNoneFalseNoneFalse25200.00
296166797889NoneBOQ331Supplying of.....feet -PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80.Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.. LED light fitting 1 x 2' - 9/10 WNos606.1606.110.0FalseNoneNoneFalseNoneFalse6061.00
296166897889NoneBOQ332LED light fitting 1 x 4' - 20/22 WNos759.0759.055.0FalseNoneNoneFalseNoneFalse41745.00
296166997889NoneBOQ333Supplying of recess mounting non integrated type LED down light......W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRIgreater than 70%.efficacy greater than100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80.The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level.LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldlesser than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.. 5-6 WNos885.5885.515.0FalseNoneNoneFalseNoneFalse13282.50
296167097889NoneBOQ334b. 12 WNos1395.91395.990.0FalseNoneNoneFalseNoneFalse125631.00
296167197889NoneBOQ335Supplying of recess mounting non integral type........LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K, CRIgreater than 70%.efficacy greater than 100 lumen per W, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF greater than 0.95, power loss shouldlesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1'x4' 34-36 WNos6487.86487.825.0FalseNoneNoneFalseNoneFalse162195.00
296167297889NoneBOQ336Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees.CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08.Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection.Compatible for pole mounting with outer dia of 40mm to 50mm.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application.Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with........W System Power consumption.LED Efficiencygreater than1301m/w, nominal CRI greater than75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part.Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned. LED Streetlight 40WNos4426.44426.42.0FalseNoneNoneFalseNoneFalse8852.80
296167397889NoneBOQ337Supply of LED Bollard light fitting of...W with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08.Power Factor greater than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection.Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application.Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS.UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 m HeightNos4981.844981.845.0FalseNoneNoneFalseNoneFalse24909.20
296167497889NoneBOQ338Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for outdoor luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.. Single Arm Bracket with 1000 mm Standard 40/50 mm diaNos1870.01870.05.0FalseNoneNoneFalseNoneFalse9350.00
296167597889NoneBOQ339Fabricating supplying and mounting MSbox madeout....SWG suitable for floor/wall mounting, fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cableentry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWGSq CM0.550.5525000.0FalseNoneNoneFalseNoneFalse13750.00
296167697889NoneBOQ340Fabricating supplying and mounting MS box made out... SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enaemeld metal paint etc., complete.. 75x75x6 mmMtr610.5610.52.0FalseNoneNoneFalseNoneFalse1221.00
296167797889NoneBOQ341Supplying....amps rated 3 phase with neutral bus bar using requred capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts 5.40.1 and washers etc., complete.. 100Amps 4x30x6mm Aluminum Strips.Mtr2711.52711.52.0FalseNoneNoneFalseNoneFalse5423.00
296167897889NoneBOQ342Supplying of multi function meter digital three line back light LCD type display of voltage, current, current, frequency, power, power factor, KVA , KWH, KVAR.suitable for 3phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication port and class 0.5s accuracyNos10246.510246.51.0FalseNoneNoneFalseNoneFalse10246.50
296167997889NoneBOQ343Supplying, fixing and wiring 50/5 to 400/5A 5VA burden current transformer.Class 0.5 accuracy with tape wound.Nos618.2618.21.0FalseNoneNoneFalseNoneFalse618.20
296168097889NoneBOQ344Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12/24V DCNos566.5566.53.0FalseNoneNoneFalseNoneFalse1699.50
296168197889NoneBOQ345Supplying fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest mnicrocontroller based, digital read out of percentage leakage current, programmable delay/auto/manual reset facility suitable to mount on DIN rail/flush mounting panel boardNos10180.510180.51.0FalseNoneNoneFalseNoneFalse10180.50
296168297889NoneBOQ346Supply and fixing Moulded case circuit breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete.Protection of overload and short circuit with thermal magnetic/micro processor releases and earth fault as per IS - 13947 Four pole. 100Amps 25kANos9335.79335.71.0FalseNoneNoneFalseNoneFalse9335.70
296168397889NoneBOQ347Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 608996-32 Amps SPNos456.5456.53.0FalseNoneNoneFalseNoneFalse1369.50
296168497889NoneBOQ348b.6-32 Amps DPNos812.9812.95.0FalseNoneNoneFalseNoneFalse4064.50
296168597889NoneBOQ349c.6-32 Amps TPNNos1888.71888.74.0FalseNoneNoneFalseNoneFalse7554.80
296168697889NoneBOQ350d.40 Amps TPNNos3348.43348.44.0FalseNoneNoneFalseNoneFalse13393.60
296168797889NoneBOQ351Supplying, erecting, testing & commissioning of OFF- LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. 3 kVA OFF LINE UPSNos32056.232056.21.0FalseNoneNoneFalseNoneFalse32056.20
296168897889NoneBOQ352Supplying, installation, testing and commissioning of 12 volts DC AH batteries in poly propylene container for UPS sealed maintainence free batteries. 12V, 75 - 80 AH capacity.Acid batteryNos11189.211189.23.0FalseNoneNoneFalseNoneFalse33567.60
296168997889NoneBOQ353Design, supplying, erecting testing and commissioning of-Passenger/Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or with out machine roomf or the available wellsize,operating at 415 V3 phase 50 cycles AC supply, powder coated/Stainless Steel carentrance door sen closures with suitable colourvinyl flooring, LED carillumination, emergency light, intercomand fan as desired by the user, central opening/side opening door with or without attend antoperation, 7segment display buttons, call register indicator, firemandrive, SShandrails insidecar, fulllength infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional/international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guiderail, counterweight etc., The total product and services shall adhere to IS14665/2016 (with latest amendments part/section 1 to 5 with regards togeneral guidelines offire safety rated doors, MRLL beams, pressures witch, manual change over for doors during emergency, ARD of 10times with sufficient battery backup and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCBNorms, National Electricity Code(NEC), NBC-2016,IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014.The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka.With Out Machine Room-SS Finish 8 passengers 3 stopsNos1604341.151604341.151.0FalseNoneNoneFalseNoneFalse1604341.150
296169097889NoneBOQ354Supplying & Laying cable trays including welding, fixing of supports Cable tray of 600 mm width (suitable for cable ducts of A, B & C type)Mtr1170.41170.435.0FalseNoneNoneFalseNoneFalse40964.00
296169197889NoneBOQ355Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293.GROUP A a) TV/ Telephone socketEach171.6171.625.0FalseNoneNoneFalseNoneFalse4290.00
296169297889NoneBOQ356b) RJ45/I.O.outletEach370.7370.745.0FalseNoneNoneFalseNoneFalse16681.50
296169397889NoneBOQ357Supplying and drawing UTP-CAT 6E LAN cable.Mtr41.841.81500.0FalseNoneNoneFalseNoneFalse62700.00
296169497889NoneBOQ358Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable.a) 2 PairMtr23.123.1600.0FalseNoneNoneFalseNoneFalse13860.00
296169597889NoneBOQ359Supplying and fixing of switch mounting rack with power manager & cable manager.6U with 450mm depthEach7674.77674.72.0FalseNoneNoneFalseNoneFalse15349.40
296169697889NoneBOQ360Supplying and fixing of power strip.Each1602.71602.72.0FalseNoneNoneFalseNoneFalse3205.40
296169797889NoneBOQ361Supplying and fixing of fan.Each1329.91329.92.0FalseNoneNoneFalseNoneFalse2659.80
296169897889NoneBOQ362Supplying & fixing of ….mtrs Cat6 Patch Cable - a) 1 mtrEach246.4246.445.0FalseNoneNoneFalseNoneFalse11088.00
296169997889NoneBOQ363Supplying & fixing of ….mtrs Cat6 Patch Cable - b) 2 mtrEach282.7282.745.0FalseNoneNoneFalseNoneFalse12721.50
296170097889NoneBOQ364Supplying & fixing of Patch Panel for LAN cabling.24 Port 10/100/1000 Patch PanelEach4510.04510.02.0FalseNoneNoneFalseNoneFalse9020.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17098088760000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17098088760000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17098088760000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17098088870000NoneNoneELIGIBILITYAll other terms and conditions as per NIT and KW4None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneThe bidders shall upload the work done certificate for having executed One building work of value not less than Rs. 175.00 lakhs and completed satisfactorily as a prime contractor within stipulated time period in the past 5 years (i.e., 2018-19 to 2022-23). Work done certificate shall be duly signed by the officer not below the rank of Executive Engineer or equivalent.(Note: Work done amount will be updated to the FY 2023-24 in which the tenders are invited. The value of the completed works will be given a weight of 10% per year to bring them to the price level of the FY 2023-24 in which the tenders are invited)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- workdone certificate as per NIT and KW4
NoneNoneNoneNoneThe bidders shall upload the work done certificate for minimum quantities of work executed in any one year, following quantities (In a continuous period of 12 months from April to March) in the last 5 years (i.e. F/Y 2018-19 to F/Y 2022-23) the certificate shall be issued by the officer not below the rank of Executive Engineer or equivalent. a.PCC/RCC 350.00 .00 Cum b.Burnt brick masonry/Solid block 216.00Cum / 1080.00 Sqm c.TMT steel reinforcement 32.00 Tonnes d.Vitrified / Ceramic / Granite flooring 2000.00 SqmCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum Quantities Certificate as per NIT and KW4
NoneNoneNoneNoneThe bidders shall achieved turnover for an amount not less than Rs.700.00 lakhs achieved in any two financial years in the past 5 years (i.e.2018-19 to 2022-23) (in all classes of civil engineering construction works only). The Turnover certificate along with Balance sheet and P & L statement of past 5 years for the Civil Engineering works only (i.e.2018-19 to 2022-23) issued from a Registered Chartered Accountant (Registered Chartered Accountant PIN must be mentioned) should be uploaded. (Note: The turnover amount will be updated to the FY 2022-23 in which the tenders are invited. The Financial turnover of previous years will be given a weightage of 10% per year to bring them to the price level of the FY 2022-23 in which the tenders are invited)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4
NoneNoneNoneNoneThe bidder/tenderer or his identified Sub contractor should upload required valid electrical licence along with consent / undertaking letter for executing building electrification works and should have executed similar electrical works totalling for Rs.17.50 lakhs in any one year in the last 5 years, (i.e. 2018-19 to 2022-23) signed by the officer not below the rank of Executive Engineer or equivalent for Electrical worksOthersElectrical licence, consent letter and Electrical workdone as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Electrical licence, consent letter and Electrical workdone as per NIT and KW4
NoneNoneNoneNoneThe bidder/tenderer or his identified Sub contractor should upload required valid PHE licence along with consent / undertaking letter for executing Water supply / Sanitary engineering works and should have executed similar Water supply / sanitary engineering works /PHE works totalling for Rs.6.60 lakhs in any one year in the last 5 years,(i.e. 2018-19 to 2022-23),signed by the officer not below the rank of Executive Engineer or equivalent for Water supply / sanitary engineering works /PHE works.OthersWater supply licence, consent letter and Water supply workdone as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Water supply licence, consent letter and Water supply workdone as per NIT and KW4
NoneNoneNoneNoneThe banker certificate as per the enclosed format shall be uploaded for availability of fund requirement for the work not less Rs.105.00 Lakhs issued by Nationalised or Scheduled Bank after this notification date, with following details.1. Cash at Bank 2.Term deposits 3.Credit facility sanctioned a. Credit Utilized b. Balance credit facility availableOthersBanker certificate As per Enclosed format as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker certificate As per Enclosed format as per NIT and KW4
NoneNoneNoneNoneBidder shall upload the self-declaration affidavit as per the enclosed format on the stamp paper of value not less than Rs. 100/- duly notarized stating that a.Not made any misleading or false representations in the forms, statements and attachments submitted in proof of the qualification requirements.b. Not made any Record of poor performance such as abandoning the works, not properly completing the contract, inordinate delays in completion or financial failures etc. c.Not participated in the previous Tender for the same work and had quoted unreasonably high tender prices and could not furnish rational justification. d.No Litigation History or arbitration arising out of contracts completed or under execution by it over the preceding five yearsOthersself-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
NoneNoneNoneNoneThe bidders shall upload a valid registered KPWD Civil contractor Licence of Class II and above.OthersKPWD Registration Certificate as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneAll other terms and conditions as per NIT and KW4OthersAll other terms and conditions as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- All other terms and conditions as per NIT and KW4
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Registration Certificate as per NIT and KW4TrueTechnical Bid
Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4TrueTechnical Bid
workdone certificate as per NIT and KW4TrueTechnical Bid
Minimum Quantities Certificate as per NIT and KW4TrueTechnical Bid
Electrical licence, consent letter and Electrical workdone as per NIT and KW4TrueTechnical Bid
Water supply licence, consent letter and Water supply workdone as per NIT and KW4TrueTechnical Bid
Banker certificate As per Enclosed format as per NIT and KW4TrueTechnical Bid
Bid Capacity as per NIT and KW4TrueTechnical Bid
self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1709828956000
version0
createdDateNone
modifiedDateNone
blockNumberFirst floor, Belaku Bhavana, BESCOM Corporate office, K R Circle, Bengaluru
streetNone
cityBengaluru
stateKarnataka
pin560001
tenderRecallDTONone