2819507 | 91068 | None | Code.1 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 266.2 | 266.2 | 321.24 | False | None | None | False | None | False | 85514.088 | 0 |
2819508 | 91068 | None | Code.2 | Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 112.2 | 112.2 | 1962.47 | False | None | None | False | None | False | 220189.134 | 0 |
2819509 | 91068 | None | Code.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork shall be paid separately). Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7043.86 | 7043.86 | 434.46 | False | None | None | False | None | False | 3060275.4156 | 0 |
2819510 | 91068 | None | Code.4 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface ofconsolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percentage E.C. / Lindane 20percentage E.C. at 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 129.8 | 129.8 | 2561.67 | False | None | None | False | None | False | 332504.766 | 0 |
2819511 | 91068 | None | Code.5 | Providing Size Stone masonry with hard stone in foundation and plinthwith Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7027.9 | 7027.9 | 111.39 | False | None | None | False | None | False | 782837.781 | 0 |
2819512 | 91068 | None | Code.6 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead and lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Plinth Beam | Cum | 10454.4 | 10454.4 | 57.66 | False | None | None | False | None | False | 602800.704 | 0 |
2819513 | 91068 | None | Code.7 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded
crushed coarse aggregates (DPC) | Cum | 7044.4 | 7044.4 | 9.27 | False | None | None | False | None | False | 65301.588 | 0 |
2819514 | 91068 | None | Code.8 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machinemixed with super plasticizers laid in finished layers, well compactedusing needle vibrators, including all lead and lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenancesrequired to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Footings | Cum | 7527.17 | 7527.17 | 217.38 | False | None | None | False | None | False | 1636256.2146 | 0 |
2819515 | 91068 | None | Code.9 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded
crushed coarse aggregates For Column upto plinth | Cum | 11848.32 | 11848.32 | 11.87 | False | None | None | False | None | False | 140639.5584 | 0 |
2819516 | 91068 | None | Code.10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift
upto 1.5 m. | Cum | 292.6 | 292.6 | 857.48 | False | None | None | False | None | False | 250898.648 | 0 |
2819517 | 91068 | None | Code.11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm
nominal size graded crushed coarse aggregates Walls | Cum | 12043.68 | 12043.68 | 151.63 | False | None | None | False | None | False | 1826183.1984 | 0 |
2819518 | 91068 | None | Code.12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M25 Design Mix Using 20 mm
nominal size graded crushed coarse aggregates For Plinth | Cum | 11290.95 | 11290.95 | 114.08 | False | None | None | False | None | False | 1288071.576 | 0 |
2819519 | 91068 | None | Code.13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M25 Design Mix Using 20 mm
nominal size graded crushed coarse aggregates For Column | Cum | 12796.41 | 12796.41 | 39.23 | False | None | None | False | None | False | 502003.1643 | 0 |
2819520 | 91068 | None | Code.14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Lintel and Roof beam | Cum | 12043.68 | 12043.68 | 114.15 | False | None | None | False | None | False | 1374786.072 | 0 |
2819521 | 91068 | None | Code.15 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Roof Slab | Cum | 11290.95 | 11290.95 | 264.7 | False | None | None | False | None | False | 2988714.465 | 0 |
2819522 | 91068 | None | Code.16 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded
crushed coarse aggregates (SILL CONCRETE) | Cum | 7044.4 | 7044.4 | 6.15 | False | None | None | False | None | False | 43323.06 | 0 |
2819523 | 91068 | None | Code.17 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Platform | Cum | 7527.3 | 7527.3 | 74.1 | False | None | None | False | None | False | 557772.93 | 0 |
2819524 | 91068 | None | Code.18 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percentage and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per sqm to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per sqm and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 898.7 | 898.7 | 1686.69 | False | None | None | False | None | False | 1515828.303 | 0 |
2819525 | 91068 | None | Code.19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. Buildings | Tonne | 98402.7 | 98402.7 | 141.59 | False | None | None | False | None | False | 13932838.293 | 0 |
2819526 | 91068 | None | Code.20 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery and other incidental
charges complete as per the direction of engineer incharge of work | Cum | 12786.4 | 12786.4 | 142.5 | False | None | None | False | None | False | 1822062.0 | 0 |
2819527 | 91068 | None | Code.21 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1441.0 | 1441.0 | 2102.85 | False | None | None | False | None | False | 3030206.85 | 0 |
2819528 | 91068 | None | Code.22 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1214.4 | 1214.4 | 538.71 | False | None | None | False | None | False | 654209.424 | 0 |
2819529 | 91068 | None | Code.23 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of
Engineer in charge. | Sqm | 110.0 | 110.0 | 1508.23 | False | None | None | False | None | False | 165905.3 | 0 |
2819530 | 91068 | None | Code.24 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 423.5 | 423.5 | 4621.75 | False | None | None | False | None | False | 1957311.125 | 0 |
2819531 | 91068 | None | Code.25 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour,
curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 324.5 | 324.5 | 4564.5 | False | None | None | False | None | False | 1481180.25 | 0 |
2819532 | 91068 | None | Code.26 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix
:1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 355.3 | 355.3 | 1518.13 | False | None | None | False | None | False | 539391.589 | 0 |
2819533 | 91068 | None | Code.27 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry at 3.3 kg/ m2 including pointing the joints with white cement and
matching pigments etc., complete. | Sqm | 977.9 | 977.9 | 1631.48 | False | None | None | False | None | False | 1595424.292 | 0 |
2819534 | 91068 | None | Code.28 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of
materials, labour, complete as per specifications | Sqm | 1593.9 | 1593.9 | 3662.73 | False | None | None | False | None | False | 5838025.347 | 0 |
2819535 | 91068 | None | Code.29 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls at 1.25 ltr/10 sqm over and including one coat of Special primer applied at 0.75 ltr /10 sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 173.8 | 173.8 | 8170.2 | False | None | None | False | None | False | 1419980.76 | 0 |
2819536 | 91068 | None | Code.30 | Providing and fixing Fibre Glass Reinforced plastic (FRP) Door Frames of cross- section 90mm X 45mm having single rebate of 32mm X 15mm to receive shutter of 30mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be coverd with fibre glass from all sides, M.S.Stay shall be provided at the bottom to steady the
frame. | Mtr | 707.3 | 707.3 | 1723.28 | False | None | None | False | None | False | 1218875.944 | 0 |
2819537 | 91068 | None | Code.31 | Providing and fixing to existing door frames Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to
frames. | Sqm | 3524.4 | 3524.4 | 499.72 | False | None | None | False | None | False | 1761213.168 | 0 |
2819538 | 91068 | None | Code.32 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor TandP's
shall not be made) 30 mm thickness | Sqm | 6290.9 | 6290.9 | 249.89 | False | None | None | False | None | False | 1572033.001 | 0 |
2819539 | 91068 | None | Code.33 | Providing and fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardwareand single point locking system with touch lock. Wall thickness of frame and sash shall be of 1.8+-0.2 mm. Maximum possible size -1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor TandP's shall not be made) | Sqm | 5929.0 | 5929.0 | 35.59 | False | None | None | False | None | False | 211013.11 | 0 |
2819540 | 91068 | None | Code.34 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with
M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 201.3 | 201.3 | 13305.74 | False | None | None | False | None | False | 2678445.462 | 0 |
2819541 | 91068 | None | Code.35 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 126.5 | 126.5 | 2774.41 | False | None | None | False | None | False | 350962.865 | 0 |
2819542 | 91068 | None | Code.36 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 621.5 | 621.5 | 1570.8 | False | None | None | False | None | False | 976252.2 | 0 |
2819543 | 91068 | None | Code.37 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 112.2 | 112.2 | 717.0 | False | None | None | False | None | False | 80447.4 | 0 |
2819544 | 91068 | None | Code.38 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm | Nos | 478.5 | 478.5 | 715.0 | False | None | None | False | None | False | 342127.5 | 0 |
2819545 | 91068 | None | Code.39 | Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm | Nos | 273.9 | 273.9 | 500.0 | False | None | None | False | None | False | 136950.0 | 0 |
2819546 | 91068 | None | Code.40 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mm | Nos | 330.0 | 330.0 | 171.0 | False | None | None | False | None | False | 56430.0 | 0 |
2819547 | 91068 | None | Code.41 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size
580x440 mm with integral type foot rests | Nos | 5372.4 | 5372.4 | 117.0 | False | None | None | False | None | False | 628570.8 | 0 |
2819548 | 91068 | None | Code.42 | Providing and fixing white vitreous china pedestal type water closet (European type
W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : | Nos | 5321.8 | 5321.8 | 59.0 | False | None | None | False | None | False | 313986.2 | 0 |
2819549 | 91068 | None | Code.43 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : One urinal basin with 5 litre
white P.V.C. automatic flushing cistern | Nos | 4899.4 | 4899.4 | 159.0 | False | None | None | False | None | False | 779004.6 | 0 |
2819550 | 91068 | None | Code.44 | Providing and fixing PTMT, push cock of approved quality and colour. 15 mm nominal bore, 98 mm long, weighing not less than 75 gms | Nos | 140.8 | 140.8 | 70.0 | False | None | None | False | None | False | 9856.0 | 0 |
2819551 | 91068 | None | Code.45 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. | Sqm | 3067.9 | 3067.9 | 13.5 | False | None | None | False | None | False | 41416.65 | 0 |
2819552 | 91068 | None | Code.46 | Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap | Nos | 4548.5 | 4548.5 | 118.0 | False | None | None | False | None | False | 536723.0 | 0 |
2819553 | 91068 | None | Code.47 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash
basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3390.2 | 3390.2 | 47.0 | False | None | None | False | None | False | 159339.4 | 0 |
2819554 | 91068 | None | Code.48 | Providing and fixing on Terrace (at all Floor levels) ployethylene water storage tank, IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for
tank | Ltr | 9.9 | 9.9 | 38000.0 | False | None | None | False | None | False | 376200.0 | 0 |
2819555 | 91068 | None | Code.49 | Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer- in-charge. The rate includes making necessary holes for inlet, outlet and over flow pipes. The base support i/c fittigs and fixtures for tanke shall be paid separately. | Ltr | 9.9 | 9.9 | 14850.0 | False | None | None | False | None | False | 147015.0 | 0 |
2819556 | 91068 | None | Code.50 | Providing and fixing Square- mouth S.W. gully trap class SP-1 complete with C.I grating Brick masonry chamber 100mm x 100mm size P type with Non modular common burnt clay bricks of designation 3.5 and water tight C.I cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70kg as per standard design. | Each | 2785.2 | 2785.2 | 210.0 | False | None | None | False | None | False | 584892.0 | 0 |
2819557 | 91068 | None | Code.51 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non
modular) bricks of class designation 3.5 | Each | 6206.2 | 6206.2 | 122.0 | False | None | None | False | None | False | 757156.4 | 0 |
2819558 | 91068 | None | Code.52 | Cutting holes up to 15 x 15 cm in R.C.C floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), including
finishing complete so as to make it leak proof. | Mtr | 344.3 | 344.3 | 296.0 | False | None | None | False | None | False | 101912.8 | 0 |
2819559 | 91068 | None | Code.53 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails and bonding rods at every 100 mm wherever necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m | Cum | 288.2 | 288.2 | 1057.48 | False | None | None | False | None | False | 304765.736 | 0 |
2819560 | 91068 | None | Code.54 | Refilling available earth around trenches/pipelines, cables in layersnot exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead
upto 50 m , and lift | Cum | 176.0 | 176.0 | 1160.32 | False | None | None | False | None | False | 204216.32 | 0 |
2819561 | 91068 | None | Code.55 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 20mm nominal OD pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (Concealed work including cutting chases and
good the walls etc.,) | Mtr | 266.2 | 266.2 | 737.65 | False | None | None | False | None | False | 196362.43 | 0 |
2819562 | 91068 | None | Code.56 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 25mm nominal OD pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (Concealed work including cutting chases and
good the walls etc.,) | Mtr | 349.8 | 349.8 | 639.9 | False | None | None | False | None | False | 223837.02 | 0 |
2819563 | 91068 | None | Code.57 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes 32mm nominal OD pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (Concealed work including cutting chases and
good the walls etc.,) | Mtr | 440.0 | 440.0 | 497.72 | False | None | None | False | None | False | 218996.8 | 0 |
2819564 | 91068 | None | Code.58 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 110mm dia., 6 kg/sqcm and class 3, | Mtr | 452.1 | 452.1 | 914.0 | False | None | None | False | None | False | 413219.4 | 0 |
2819565 | 91068 | None | Code.59 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g. | Nos | 930.6 | 930.6 | 321.0 | False | None | None | False | None | False | 298722.6 | 0 |
2819566 | 91068 | None | Code.60 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g | Nos | 110.0 | 110.0 | 103.0 | False | None | None | False | None | False | 11330.0 | 0 |
2819567 | 91068 | None | Code.61 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : 150 mm diameter | Nos | 306.9 | 306.9 | 30.0 | False | None | None | False | None | False | 9207.0 | 0 |
2819568 | 91068 | None | Code.62 | Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality and make as approved by Engineer in charge. | Nos | 6118.2 | 6118.2 | 30.0 | False | None | None | False | None | False | 183546.0 | 0 |
2819569 | 91068 | None | Code.63 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with
S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. | Each | 299.2 | 299.2 | 18.0 | False | None | None | False | None | False | 5385.6 | 0 |
2819570 | 91068 | None | Code.64 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved
quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Nos | 1342.0 | 1342.0 | 125.0 | False | None | None | False | None | False | 167750.0 | 0 |
2819571 | 91068 | None | Code.65 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and
effective height of 88 mm, weighing not less than 190 g. | Nos | 545.6 | 545.6 | 178.0 | False | None | None | False | None | False | 97116.8 | 0 |
2819572 | 91068 | None | Code.66 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc
coating not less than 275 g/sqm) | Mtr | 709.5 | 709.5 | 237.0 | False | None | None | False | None | False | 168151.5 | 0 |
2819573 | 91068 | None | Code.67 | Providing and fixing MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fixing in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all
lead and lifts etc. complete with: MS angle of 65 x 65 x 8mm | Mtr | 4814.7 | 4814.7 | 94.4 | False | None | None | False | None | False | 454507.68 | 0 |
2819574 | 91068 | None | Code.68 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:
PVC pipes 160mm dia., 6 kg/sqcm and class 3 | Mtr | 679.8 | 679.8 | 1784.0 | False | None | None | False | None | False | 1212763.2 | 0 |
2819575 | 91068 | None | Code.69 | Dismantling of Flexible pavements and disposal of dismantled materials and stacking serviceable and unserviceable materials separately By II) Mechanical Means A) Bituminous course | Cum | 354.2 | 354.2 | 160.56 | False | None | None | False | None | False | 56870.352 | 0 |
2819576 | 91068 | None | Code.70 | Direction and Place Identification Signs upto 0.9 m2 Size Board.Providing and erecting direction and place identification retro-reflectorised sign as perIRC:67:2012 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick or Aluminium composite material sheet with overall thickness of 4mm with area not exceeding 0.9 m2 fixed over back support frame of min 35 x 35 x 3mm angle mounted on a mild steel circular pipe 65 NB, firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 x 45 x 60
cm, 60 cm below ground level as per approved drawing | Sqm | 9911.0 | 9911.0 | 113.37 | False | None | None | False | None | False | 1123610.07 | 0 |
2819577 | 91068 | None | Code.71 | Providing and laying 60mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 and IS 15658 for Cycle Tracks and Pedestrian Footpaths of approved shape and colour, laid in required pattern and including over 30mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-incharge. (WMM/WBM Base to be paid
separately if necessary as per relevant technical specification) | Sqm | 1174.8 | 1174.8 | 1042.5 | False | None | None | False | None | False | 1224729.0 | 0 |
2819578 | 91068 | None | Code.72 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) 300 x 300 x 150 mm Kerb
Stone | Mtr | 413.6 | 413.6 | 695.0 | False | None | None | False | None | False | 287452.0 | 0 |
2819579 | 91068 | None | Code.73 | Providing and fixing White vitreous china water closet squatting pan (Indian type) along with inchSinch or inchPinch trap including dismantling of old WC seat and inchSinch or inchPinch trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge.Orissa pattern W.C Pan of size 580x440 mm (PWD SR 2023-24, Pg No 202
Item No.20.44.2, Vol-II) | Nos | 3901.7 | 3901.7 | 30.0 | False | None | None | False | None | False | 117051.0 | 0 |
2819580 | 91068 | None | Code.74 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. (PWD SR
2023-24, Pg No 132 Item No.14.7.4, Vol-II) | Each | 2579.5 | 2579.5 | 12.0 | False | None | None | False | None | False | 30954.0 | 0 |
2819581 | 91068 | None | Code.75 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore (PWD SR 2023-24 Pg No 117 Item No.13.2.1, Vol-II) | Each | 314.6 | 314.6 | 155.0 | False | None | None | False | None | False | 48763.0 | 0 |
2819582 | 91068 | None | Code.76 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles 10 mm to 25 mm (PWD SR 2023-24 Pg No 189 Item No.19.22.1,
Vol-II) | Sqm | 52.8 | 52.8 | 458.58 | False | None | None | False | None | False | 24213.024 | 0 |
2819583 | 91068 | None | Code.77 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete.s
(PWD SR 2023-24, Item No.10.14, Pg No.71, Vol-II) | Sqm | 1216.6 | 1216.6 | 29.84 | False | None | None | False | None | False | 36303.344 | 0 |
2819584 | 91068 | None | Code.78 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. as per specifications and as per directions of Engineer in
charge. (PWD SR 2023-24, Pg No 51 Item No.8.60, Vol-II) | Sqm | 18.7 | 18.7 | 24.86 | False | None | None | False | None | False | 464.882 | 0 |
2819585 | 91068 | None | Code.79 | Removing white wash or colour wash by steel brushing and / or scraping, sand papering and preparing wall surface smooth including repairs to scraches including cost of labour, material complete as per specifications. (PWD SR 2023-24, Pg No 203
Item No.20.50, Vol-II) | Sqm | 14.3 | 14.3 | 863.03 | False | None | None | False | None | False | 12341.329 | 0 |
2819586 | 91068 | None | Code.80 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of
Engineer in charge.(PWD SR 2023-24 , Pg No 51 Item No.8.63, Vol-II) | Sqm | 90.2 | 90.2 | 584.42 | False | None | None | False | None | False | 52714.684 | 0 |
2819587 | 91068 | None | Code.81 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (One coat applied at 0.90 ltr/10 sqm) including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.
(PWD SR 2023-24, Pg No 53 Item No.8.74.2, Vol-II) | Sqm | 75.9 | 75.9 | 427.55 | False | None | None | False | None | False | 32451.045 | 0 |
2819588 | 91068 | None | Code.82 | Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied at 1.2L/per m2,having tensile strength greaterthan 1.5N/mm2, elongation greater than 300percentage with solid content not less than 60percentage in 2 coats including surface preparation, priming the surface with water based acrylic primer at0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work fromcertified manufacturers as per the direction of the Engineer In charge. (PWD SR
2023-24, Pg No 149 Item No.15.2, Vol-II) | Sqm | 810.7 | 810.7 | 139.79 | False | None | None | False | None | False | 113327.753 | 0 |
2819589 | 91068 | None | Code.83 | Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete 75mm (PWD SR 2023 Vol-II,P108 ITEM NO 12.77.4) | Nos | 422.4 | 422.4 | 4.0 | False | None | None | False | None | False | 1689.6 | 0 |
2819590 | 91068 | None | Code.84 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. (For Roof and Water Tanks) ( PWD SR 2023 Vol-II,P-201 item no 20.38) | Sqm | 569.8 | 569.8 | 65.11 | False | None | None | False | None | False | 37099.678 | 0 |
2819591 | 91068 | None | Code.85 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking to the appropriate disposal area as per direction of Engineerin-charge. Of area 3 sqm and below (PWD SR 2023-
24, Pg No 188 Item No. 19.12.1, Vol-II) | Sqm | 264.0 | 264.0 | 104.16 | False | None | None | False | None | False | 27498.24 | 0 |
2819592 | 91068 | None | Code.86 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of engineer incharge . Concealed work including cutting chases and good the walls etc.
32 mm nominal OD pipes ( PWD SR 2023 Vol-II, Item No.13.33.4 Pg-122) | Mtr | 409.2 | 409.2 | 9.0 | False | None | None | False | None | False | 3682.8 | 0 |
2819593 | 91068 | None | Code.87 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore 13.4.1 ( PWD SR 2023 Vol-II,page no117 Item
No.13.4.1) | Nos | 603.9 | 603.9 | 3.0 | False | None | None | False | None | False | 1811.7 | 0 |
2819594 | 91068 | None | Code.88 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality
(screwed end) : 32 mm nominal bore 13.4.2 ( PWD SR 2023 Vol-II,page no117 Item No.13.4.2) | Nos | 657.8 | 657.8 | 4.0 | False | None | None | False | None | False | 2631.2 | 0 |
2819595 | 91068 | None | Code.89 | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover and frame etc. excluding the cost of CI frame
and cover. (CSR 2023-24, Pg No191, Item No. 16.10, Vol-V) | Nos | 4659.6 | 4659.6 | 2.0 | False | None | None | False | None | False | 9319.2 | 0 |
2819596 | 91068 | None | Code.90 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps 14.7.3 ( PWD SR
2023 Vol-II,page no132 Item No.14.7.3) | Each | 3152.6 | 3152.6 | 4.0 | False | None | None | False | None | False | 12610.4 | 0 |
2819597 | 91068 | None | Code.91 | Providing and fixing PVC (S.W.R) P Trap 10cms x 10cms with all fitting arrangements and all necessary accessories complete (PWD SR 2023 Vol-II,P-127 item
no 13.6) | Nos | 339.9 | 339.9 | 14.0 | False | None | None | False | None | False | 4758.6 | 0 |
2819598 | 91068 | None | Code.92 | Providing and fixing PVC (S.W.R) S Trap 10cms x 10cms with all fitting
arrangements and all necessary accessories complete (PWD SR 2023 Vol-II,P-127 item no 13.62) | Nos | 393.8 | 393.8 | 14.0 | False | None | None | False | None | False | 5513.2 | 0 |
2819599 | 91068 | None | Code.93 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0 cm X
4.0 cm with all fitting arrangements and all necessary accessories complete (PWD SR 2023 Vol-II,P-128 item no 13.63) | Nos | 268.4 | 268.4 | 14.0 | False | None | None | False | None | False | 3757.6 | 0 |
2819600 | 91068 | None | Code.94 | Providing and fixing PTMT grating of approved quality and colour 125 mm nominal dia (PWD SR 2023 Vol-II,P-120 item no 13.22.1.2) | Nos | 48.4 | 48.4 | 29.0 | False | None | None | False | None | False | 1403.6 | 0 |
2819601 | 91068 | None | Code.95 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.1 M depth and SFRC cover and frame M.H: ( CSR FOR WATER SUPPLY AND SEWERAGE Works 2023 Vol-5,page no192 Item No.16.15.2) | Nos | 32484.1 | 32484.1 | 1.0 | False | None | None | False | None | False | 32484.1 | 0 |
2819602 | 91068 | None | Code.96 | Providing and fixing on wall face unplasticized Rigid PVC Rain water pipes confirming to IS : 13592 Type A Including jointing with seal ring confirming to IS : 5382, Leaving 10mm gap for Thermal expansion, (i) Single Socked pipes 100mm
daimeter. 13.48 (PWD SR 2023 Vol-II,P-125 item no 13.48) | Mtr | 320.1 | 320.1 | 28.0 | False | None | None | False | None | False | 8962.8 | 0 |
2819603 | 91068 | None | Code.97 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM. ( CSR FOR WATER SUPPLY AND
SEWERAGE Works 2023 Vol-5,page no157 Item No.13.40.1) | Nos | 17171.0 | 17171.0 | 1.0 | False | None | None | False | None | False | 17171.0 | 0 |
2819604 | 91068 | None | Code.98 | Providing and fixing unbranded Polypropylene waste container and accessories
having 40 litre capacity complete as per specifications including all lead and lifts as per the direction of Engineer in charge (Data Rate). | Nos | 249.0 | 249.0 | 239.0 | False | None | None | False | None | False | 59511.0 | 0 |
2819605 | 91068 | None | Code.99 | Providing and fixing Twin Bin Waste Container and accessories having 120 litre capacity of Class A Stainless Steel material complete as per specifications including
all lead and lifts as per the direction of Engineer in charge (Data Rate). | Nos | 600.0 | 600.0 | 92.0 | False | None | None | False | None | False | 55200.0 | 0 |
2819606 | 91068 | None | Code.100 | Providing and fixing Sanitary napkins vending machin dryer and accessoriesl complete as per specifications including all lead and lifts as per the direction of
Engineer in charge (Data Rate). | Nos | 5788.0 | 5788.0 | 92.0 | False | None | None | False | None | False | 532496.0 | 0 |
2819607 | 91068 | None | Code.101 | Providing and fixing Fully Automatic hand dryer Rated power 2500W,220Voltage,Frequancy15 Hz,Motor speed 6000rpm and accessories Plastic material complete as per specifications including all lead and lifts as per the direction
of Engineer in charge (Data Rate). | Nos | 2845.0 | 2845.0 | 184.0 | False | None | None | False | None | False | 523480.0 | 0 |
2819608 | 91068 | None | Code.102 | Providing and fixing M-fold wall mounted tissue paper Dispanser and accessoriesl complete as per specifications including all lead and lifts as per the direction of
Engineer in charge (Data Rate). | Nos | 1514.0 | 1514.0 | 184.0 | False | None | None | False | None | False | 278576.0 | 0 |
2819609 | 91068 | None | Code.103 | Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and formwork to be paid separately) M25 Design Mix Using 20 mm
nominal size graded crushed coarse aggregates | Cum | 7840.8 | 7840.8 | 230.3 | False | None | None | False | None | False | 1805736.24 | 0 |
2819610 | 91068 | None | Code.104 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10454.4 | 10454.4 | 35.28 | False | None | None | False | None | False | 368831.232 | 0 |
2819611 | 91068 | None | Code.105 | Providing and laying water proofing treatment to the Water tanks and Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50percentage applied at 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation
completely as per specification. | Sqm | 557.7 | 557.7 | 980.0 | False | None | None | False | None | False | 546546.0 | 0 |
2819612 | 91068 | None | Code.106 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive
approved paint etc. complete including all lead and lifts etc. | Nos | 2354.0 | 2354.0 | 72.0 | False | None | None | False | None | False | 169488.0 | 0 |
2819613 | 91068 | None | Code.107 | Providing, supplying to work site,Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications,with testing of as per instructions of engineer incharge of work and latest amendments. 1.00
HP/0.75KW 7 STG | Nos | 14649.8 | 14649.8 | 70.0 | False | None | None | False | None | False | 1025486.0 | 0 |
2819614 | 91068 | None | Code.108 | Supplying heavy gauge PVC conduit pipe .dia mm thick confirming to IS
2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. - 19/20MM | Mtr | 69.0 | 69.0 | 2970.0 | False | None | None | False | None | False | 204930.0 | 0 |
2819615 | 91068 | None | Code.109 | Supplying heavy gauge PVC conduit pipe .dia mm thick confirming to IS
2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. - 25 mm dia 2 mm thick | Mtr | 81.0 | 81.0 | 825.0 | False | None | None | False | None | False | 66825.0 | 0 |
2819616 | 91068 | None | Code.110 | Electrical - Concealed Conduit System Supplying heavy gauge PVC conduit pipe
…19/20…mm dia .2..mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary,as per the directions of Engineer in charge of the work.
1) 19/20mm dia 2mm thick | Mtr | 66.0 | 66.0 | 2505.0 | False | None | None | False | None | False | 165330.0 | 0 |
2819617 | 91068 | None | Code.111 | Concealed Conduit System - Supplying heavy gauge PVC conduit pipe …25…mm dia
....2...mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary and as per the directions of Engineer in charge of the work. 2) 25mm dia 2mm thick | Mtr | 78.0 | 78.0 | 271.0 | False | None | None | False | None | False | 21138.0 | 0 |
2819618 | 91068 | None | Code.112 | Groove cutting Supplying heavy gauge PVC Conduit Pipe 19/20….dia ...2 mm
thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary ,as per the directions of Engineer in charge of the work.
1) 19/20mm dia 2mm thick | Mtr | 68.0 | 68.0 | 332.0 | False | None | None | False | None | False | 22576.0 | 0 |
2819619 | 91068 | None | Code.113 | Groove cutting Supplying heavy gauge PVC Conduit Pipe 25.dia .2.mm thick with suitable size bends, metal junction boxes adhesive
paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary ,as per the directions of Engineer in charge of the work.
1) 25mm dia 2mm thick | Mtr | 79.0 | 79.0 | 150.0 | False | None | None | False | None | False | 11850.0 | 0 |
2819620 | 91068 | None | Code.114 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work.
1) Short point upto 3Mtr. from tapping point to out let via switch. | Point | 269.0 | 269.0 | 1183.0 | False | None | None | False | None | False | 318227.0 | 0 |
2819621 | 91068 | None | Code.115 | Point wiring using copper wire with out switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase and Neutral) and 1x1.0 sqmm (Earth wire) FRLSH multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. as per the directions of Engineer in charge of the work.
2) Medium point above 3Mtr. Upto 6Mtr. from tapping point to out let via switch | Point | 379.0 | 379.0 | 910.0 | False | None | None | False | None | False | 344890.0 | 0 |
2819622 | 91068 | None | Code.116 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as
per the directions of Engineer in charge of the work. 1) 1.5 Sqmm | Mtr | 26.0 | 26.0 | 724.0 | False | None | None | False | None | False | 18824.0 | 0 |
2819623 | 91068 | None | Code.117 | Wiring for lighting/power circuit using one of FRLSH PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments ,as
per the directions of Engineer in charge of the work. 2) 2.5 Sqmm | Mtr | 42.0 | 42.0 | 1385.0 | False | None | None | False | None | False | 58170.0 | 0 |
2819624 | 91068 | None | Code.118 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall and as per the directions of Engineer in charge
of the work. iii) 1-3 Way | Nos | 138.0 | 138.0 | 411.0 | False | None | None | False | None | False | 56718.0 | 0 |
2819625 | 91068 | None | Code.119 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall and as per the directions of Engineer in charge
of the work. iii) 4-5 Way | Nos | 177.0 | 177.0 | 224.0 | False | None | None | False | None | False | 39648.0 | 0 |
2819626 | 91068 | None | Code.120 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall and as per the directions of Engineer in charge
of the work. iii) 6 Way | Nos | 220.0 | 220.0 | 156.0 | False | None | None | False | None | False | 34320.0 | 0 |
2819627 | 91068 | None | Code.121 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in
charge of the work. iv) 1-3 Module | Each | 161.0 | 161.0 | 411.0 | False | None | None | False | None | False | 66171.0 | 0 |
2819628 | 91068 | None | Code.122 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in
charge of the work. iv) 4 Module | Each | 175.0 | 175.0 | 224.0 | False | None | None | False | None | False | 39200.0 | 0 |
2819629 | 91068 | None | Code.123 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required Nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box. and as per the directions of Engineer in
charge of the work. iv) 6 Module | Each | 234.0 | 234.0 | 156.0 | False | None | None | False | None | False | 36504.0 | 0 |
2819630 | 91068 | None | Code.124 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in
charge of the work. i) 6 Amps one way switch | Each | 102.0 | 102.0 | 1254.0 | False | None | None | False | None | False | 127908.0 | 0 |
2819631 | 91068 | None | Code.125 | Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293. and as per the directions of Engineer in
charge of the work. ii) 6 Amps 3 way socket | Each | 171.0 | 171.0 | 345.0 | False | None | None | False | None | False | 58995.0 | 0 |
2819632 | 91068 | None | Code.126 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. 20inchX20inchx2.5inch as per the directions of the engineer in
charge of the work. | Each | 181.0 | 181.0 | 70.0 | False | None | None | False | None | False | 12670.0 | 0 |
2819633 | 91068 | None | Code.127 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required
confirming to IEC 60898 | Each | 811.0 | 811.0 | 288.0 | False | None | None | False | None | False | 233568.0 | 0 |
2819634 | 91068 | None | Code.128 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K ioutgoing SPMCB 4 Nosand complete
wiring as required confirming to IEC 60898. 50-63Amps SP | Each | 739.0 | 739.0 | 70.0 | False | None | None | False | None | False | 51730.0 | 0 |
2819635 | 91068 | None | Code.129 | Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. | Each | 401.0 | 401.0 | 70.0 | False | None | None | False | None | False | 28070.0 | 0 |
2819636 | 91068 | None | Code.130 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be
mounted in a thermoplastic / powder coated metal box and wired Completely - 10A | Each | 945.0 | 945.0 | 70.0 | False | None | None | False | None | False | 66150.0 | 0 |
2819637 | 91068 | None | Code.131 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting.
Made out of 14 SWG MS enclosure. 1) Single Door 4 Way SP andN | Each | 1241.0 | 1241.0 | 70.0 | False | None | None | False | None | False | 86870.0 | 0 |
2819638 | 91068 | None | Code.132 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter | Each | 5705.0 | 5705.0 | 70.0 | False | None | None | False | None | False | 399350.0 | 0 |
2819639 | 91068 | None | Code.133 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C and as per the directions of Engineer in
charge of the work. | Each | 515.0 | 515.0 | 27.0 | False | None | None | False | None | False | 13905.0 | 0 |
2819640 | 91068 | None | Code.134 | Supplying exhaust fan of 1440 RPM of 300 mm(12') size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply, ,as per
directions of engineer incharge of the work. | Each | 1492.0 | 1492.0 | 319.0 | False | None | None | False | None | False | 475948.0 | 0 |
2819641 | 91068 | None | Code.135 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with
locking type holder completely wired. Excluding Ballast and Fluorescent Tube.1 x 2' Tube light fitting | Nos | 185.0 | 185.0 | 787.0 | False | None | None | False | None | False | 145595.0 | 0 |
2819642 | 91068 | None | Code.136 | Supplying and Fixing of 25mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or CI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires complete. Make - Group inchAinch
materials and as per the directions of Engineer in charge of the work. | Each | 978.0 | 978.0 | 455.0 | False | None | None | False | None | False | 444990.0 | 0 |
2819643 | 91068 | None | Code.137 | Fixing all types and all capacities of LED light fittings indoor on the wall / ceiling
/rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks , holder with adopter and clamps.. a) On wall/ceiling/Rafter/Girders ,as per the directions of Engineer in charge of the work. | Each | 122.0 | 122.0 | 673.0 | False | None | None | False | None | False | 82106.0 | 0 |
2819644 | 91068 | None | Code.138 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. Ceiling rose wisth sufficient length of 23/0.0076 inch PVC insulated twincore
wire ,as per directions of engineer incharge of the work. | Each | 492.0 | 492.0 | 308.0 | False | None | None | False | None | False | 151536.0 | 0 |
2819645 | 91068 | None | Code.139 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proprotion of salt and charcoal 150mm alround the pipe to complete depth. The connection from the pipe to the conduit etc, is to be established through GI wire/ strips of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia ,as per directions of engineer
incharge of the work. | Nos | 3510.0 | 3510.0 | 70.0 | False | None | None | False | None | False | 245700.0 | 0 |
2819646 | 91068 | None | Code.140 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers, ,as per directions of engineer incharge of the work.
I) GI Wire c) 8swg | Mtr | 19.0 | 19.0 | 678.0 | False | None | None | False | None | False | 12882.0 | 0 |
2819647 | 91068 | None | Code.141 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part- 1, Armouring strip thickness in average +5percentage and resistivity 14 Ohms/Kms (Max) as per IS-3975 4 core 16 sqmm | Mtr | 150.0 | 150.0 | 2100.0 | False | None | None | False | None | False | 315000.0 | 0 |
2819648 | 91068 | None | Code.142 | Providing and laying in position 100mm dia stone ware pipe in existing trench | Mtr | 215.0 | 215.0 | 350.0 | False | None | None | False | None | False | 75250.0 | 0 |
2819649 | 91068 | None | Code.143 | Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than
3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV. 65mm | Mtr | 566.0 | 566.0 | 700.0 | False | None | None | False | None | False | 396200.0 | 0 |
2819650 | 91068 | None | Code.144 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc.complete as per direction of Engineer-in-charge. (PWD SR
2023-24, Pg202 No Item No.20.45, Vol-II) | Each | 243.1 | 243.1 | 39.0 | False | None | None | False | None | False | 9480.9 | 0 |
2819651 | 91068 | None | Code.145 | Supply Toilet Deodrant, Air freshner, Bleaching Powder 0.25 Kg/day, Domex Toilet Cleaner Disinfcatnt 0.25ltr/day, Chemical Liquid Acid for Existing Tiles Cleaning 0.25ltr/day forfor operation and maintenance of new toilets for 1 year. (Data Rate). | Nos | 20000.0 | 20000.0 | 70.0 | False | None | None | False | None | False | 1400000.0 | 0 |
2819652 | 91068 | None | Code.146 | Supply Toilet Deodrant,Air freshner for operation and maintenance of upgraded toilets for 1 year. | Nos | 33.0 | 33.0 | 264.0 | False | None | None | False | None | False | 8712.0 | 0 |
2819653 | 91068 | None | Code.147 | Supply Bleaching Powder for operation and maintenance of upgraded toilets for 1 year. | Nos | 11.0 | 11.0 | 2025.0 | False | None | None | False | None | False | 22275.0 | 0 |
2819654 | 91068 | None | Code.148 | Supply Domex Toilet Cleaner Disinfcatnt for operation and maintenance of upgraded toilets for 1 year. | Nos | 132.0 | 132.0 | 1981.0 | False | None | None | False | None | False | 261492.0 | 0 |
2819655 | 91068 | None | Code.149 | Supply Chemical Liquid Acid for Existing Tiles Cleaning for operation and maintenance of upgraded toilets for 1 year. | Nos | 40.0 | 40.0 | 2003.0 | False | None | None | False | None | False | 80120.0 | 0 |