3010797 | 100542 | None | code01 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates (PWD CSR 2023 24, Volume I It No 2.1.4 Page No 63 64) | Cum | 6963.04 | 6963.04 | 6.91 | False | None | None | False | None | False | 48114.6064 | 0 |
3010798 | 100542 | None | code02 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620 1979 having compressive strength not less then 3.5 N mm2 for saturated dry samples. For Superstructure in CM 1:6 1st Corrigendum and Addendum order 21 04 2022(PWD CSR 2023 24, Volume II It No 5.7 Page No 9) | Cum | 7565.6 | 7565.6 | 32.02 | False | None | None | False | None | False | 242250.512 | 0 |
3010799 | 100542 | None | code03 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. (PWD CSR 2023 24, Volume II It No 8.3.2 Page No 41) | Sqm | 372.96 | 372.96 | 444.44 | False | None | None | False | None | False | 165758.3424 | 0 |
3010800 | 100542 | None | code04 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Volume 2(PWD CSR 2023 24 It No 11.34A Page,No.86) | Kg | 188.16 | 188.16 | 690.9 | False | None | None | False | None | False | 129999.744 | 0 |
3010801 | 100542 | None | code05 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer in charge. (PWD CSR 2023 24 Volume II It.No 8.33.3 Page 47) | Sqm | 155.68 | 155.68 | 34.52 | False | None | None | False | None | False | 5374.0736 | 0 |
3010802 | 100542 | None | code06 | Providing & fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermal Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2 2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(PWD CSR 2023 24, Volume II It No 12.88 Page No 110) | Sqm | 6036.8 | 6036.8 | 8.64 | False | None | None | False | None | False | 52157.952 | 0 |
3010803 | 100542 | None | code07 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D 3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm 2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD CSR 2023 24 Volume II It No 12.92 Page No 112) | Sqm | 6994.4 | 6994.4 | 15.12 | False | None | None | False | None | False | 105755.328 | 0 |
3010804 | 100542 | None | code08 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in charge. (PWD CSR 2023 24, Volume II It No 8.1.2 Page No 41) | Sqm | 269.92 | 269.92 | 88.89 | False | None | None | False | None | False | 23993.1888 | 0 |
3010805 | 100542 | None | code09 | Providing and laying Vitrified tiles with thickness 9 10 mm in floor with different sizes with water absorption less than 0.08 and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm (PWD CSR 2023 24 Volume II It.No 9.21.2 Page 62) | Sqm | 1386.56 | 1386.56 | 77.92 | False | None | None | False | None | False | 108040.7552 | 0 |
3010806 | 100542 | None | code10 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.(PWD CSR 2021 22, Volume II It No 9.38 Page No 65) | Sqm | 1559.04 | 1559.04 | 43.96 | False | None | None | False | None | False | 68535.3984 | 0 |
3010807 | 100542 | None | code11 | Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C. automatic flushing cistern, with fittings, standard size G.I. PVC flush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required Single squatting plate with 5 litre P.V.C. automatic flushing cistern : (PWD CSR 2023 24, Volume II It No 14.6.1 Page No 132) | Sqm | 7414.4 | 7414.4 | 1.0 | False | None | None | False | None | False | 7414.4 | 0 |
3010808 | 100542 | None | code12 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 20 mm nominal dia pipes (PWD CSR 2023 24, Volume II It No 13.32.2 Page No 122 | Sqm | 424.48 | 424.48 | 50.0 | False | None | None | False | None | False | 21224.0 | 0 |
3010809 | 100542 | None | code13 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc 32 mm nominal dia pipes (PWD CSR 2023 24, Volume II It No 13.32.4 Page No 122) | Sqm | 623.84 | 623.84 | 30.0 | False | None | None | False | None | False | 18715.2 | 0 |
3010810 | 100542 | None | code14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and anufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (PWD CSR 2023 24, Volume II It No 8.51 Page No 50) | Sqm | 112.0 | 112.0 | 342.3 | False | None | None | False | None | False | 38337.6 | 0 |
3010811 | 100542 | None | code15 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr 10 m² over and including one coat of Special primer applied @ 0.75 ltr 10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer in charge.(PWD CSR 2023 24, Volume II It No 8.33.1 Page No 46) | Sqm | 154.56 | 154.56 | 533.33 | False | None | None | False | None | False | 82431.4848 | 0 |
3010812 | 100542 | None | code16 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 1000 mm dia (PWD CSR 2023 24, Volume III It No 16.15(B) Page No 146 ) | Sqm | 8912.96 | 8912.96 | 1.8 | False | None | None | False | None | False | 16043.328 | 0 |
3010813 | 100542 | None | code17 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from the excavation etc. complete. 110mm(weight of pipe 1.315 kg) Volume V BWSSB(PWD CSR 2023 24, It.No.10.14.4 Page.No.120 ) | Sqm | 315.84 | 315.84 | 8.0 | False | None | None | False | None | False | 2526.72 | 0 |
3010814 | 100542 | None | code18 | PART 3(ELECTRIFICATION) Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends, metal PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick( It. No 1.2.2 Electrical Sr 2023 24 Page. No 1) | Mtr | 78.0 | 78.0 | 250.0 | False | None | None | False | None | False | 19500.0 | 0 |
3010815 | 100542 | None | code19 | Supplying and fixing PVC metal conduit Deep junction box 25mm deep junction box( It. No 1.5.2 Electrical Sr 2023 24 Page. No 1) | Nos | 56.0 | 56.0 | 35.0 | False | None | None | False | None | False | 1960.0 | 0 |
3010816 | 100542 | None | code20 | Extra for Groove cutting in brick wall CC floor to the suitable depth for concealing of Conduit GI pipe and plastering, finishing upto wall surface complete.upto 50mm conduit in brick wall( It. No 1.7.1 Electrical Sr 2021 22 Page. No 2) | Mtr | 29.0 | 29.0 | 75.0 | False | None | None | False | None | False | 2175.0 | 0 |
3010817 | 100542 | None | code21 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box.( It. No 3.7 Electrical Sr 2023 24 Page. No 6) | Nos | 646.0 | 646.0 | 2.0 | False | None | None | False | None | False | 1292.0 | 0 |
3010818 | 100542 | None | code22 | Supplying and drawing PVC insulated flexible copper wire of approved make..23 0.0040” ( It. No 2.4.2 Electrical Sr 2023 24 Page. No 3) | Mtr | 22.0 | 22.0 | 800.0 | False | None | None | False | None | False | 17600.0 | 0 |
3010819 | 100542 | None | code23 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments.1.5 sqmm ( It. No 2.3.2 Electrical Sr 2023 24 Page. No 3) | Mtr | 26.0 | 26.0 | 1200.0 | False | None | None | False | None | False | 31200.0 | 0 |
3010820 | 100542 | None | code24 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 2 Way ( It. No 3.1.1 Electrical Sr 2023 24 Page. No 5) | Nos | 128.0 | 128.0 | 40.0 | False | None | None | False | None | False | 5120.0 | 0 |
3010821 | 100542 | None | code25 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. ( It. No 3.6.1 Electrical Sr 2023 24 Page. No 5) | Nos | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 |
3010822 | 100542 | None | code26 | Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 4 5Way ( It. No 3.3.2 Electrical Sr 2023 24 Page. No 5) | Nos | 124.0 | 124.0 | 10.0 | False | None | None | False | None | False | 1240.0 | 0 |
3010823 | 100542 | None | code27 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box. 3 Module ( It. No 3.5 Electrical Sr 2023 24 Page. No 5) | Nos | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 |
3010824 | 100542 | None | code28 | Supplying PVC GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely ( It. No 1.9.1 Electrical Sr 2023 24 Page. No 2) | Mtr | 19.0 | 19.0 | 25.0 | False | None | None | False | None | False | 475.0 | 0 |
3010825 | 100542 | None | code29 | Fixing a ceiling Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 0.0076 inch PVC insulated twin twisted copper wire and wiring.( It. No 13.10 Electrical Sr 2023 24 Page. No 46) | Nos | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 |
3010826 | 100542 | None | code30 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS 374 1979 and with double ball bearing system.48" Sweep (1200mm) Regular model( It. No 6.3.1 Electrical Sr 2023 24 Page. No 22) | Nos | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 |
3010827 | 100542 | None | code31 | Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220 240V @ 50 60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' 36 40 W( It. No 11.3.3 Electrical Sr 2023 24 Page. No 34) | Nos | 1269.0 | 1269.0 | 10.0 | False | None | None | False | None | False | 12690.0 | 0 |
3010828 | 100542 | None | code32 | Fixing all types and all capacities of 1'x4' 2'x2' LED Light fittings indoor on the wall ceiling rafters girders with necessary supporting frame, using 23 0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps..( It. No 13.19 Electrical Sr 2023 24 Page. No 47) | Nos | 490.0 | 490.0 | 10.0 | False | None | None | False | None | False | 4900.0 | 0 |
3010829 | 100542 | None | code33 | Supplying of recess mounting non integrated type LED down light ...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70 . efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and ompliance to IS 10322 IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhancesthe lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5 of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 , Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.1) 5 6W( It. No 11.4.1 Electrical Sr 2023 24 Page. No 44) | Nos | 805.0 | 805.0 | 10.0 | False | None | None | False | None | False | 8050.0 | 0 |
3010830 | 100542 | None | code34 | Supplying & Fixing of 70 150 Watts lamp holder 2 Pin( It. No 12.46 Electrical Sr 2023 24 Page. No 76) | Nos | 63.0 | 63.0 | 10.0 | False | None | None | False | None | False | 630.0 | 0 |
3010831 | 100542 | None | code35 | Earthing: Providing and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.( It. No 13.39 Electrical Sr 2023 24 Page. No 157) | Nos | 3750.0 | 3750.0 | 1.0 | False | None | None | False | None | False | 3750.0 | 0 |