createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710228886795
version9
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd390000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose26-03-2024 16:00:00
tenderQueryClose21-03-2024 14:30:00
technicalBidOpen27-03-2024 16:00:01
publishedDate12-03-2024 15:45:24
publishedByPostEWHFWD_CE_CEOFF_BNG
publishedByUserKPE16838 - BALEKATTE KUMARASWAMY PAVITHRA
bidValidityPeriod90
noOfCalls2
preBidMeetingDate22-03-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonTechnical Assistant.
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029557023
mobileNumber9449843294
tenderSupplierListNone
tenderSchedule
createdTs1710228886798
version22
createdDateNone
modifiedDateNone
tenderNumberEWHFWD/2023-24/BD/WORK_INDENT105/CALL-2
titleUp-gradation of infrastructure facilities and Construction of STP works to the TLH and MCH Khanapur in Belagavi District, 2)Up-gradation of infrastructure facilities to CHC at Kittur in Belagavi District,3)Construction of STP at CHC Harugeri in Raibag taluk, Belagavi District.(Pkg-17/2023-24)CHC
descriptionUp-gradation of infrastructure facilities and Construction of STP works to the TLH and MCH Khanapur in Belagavi District, 2)Up-gradation of infrastructure facilities to CHC at Kittur in Belagavi District,3)Construction of STP at CHC Harugeri in Raibag taluk, Belagavi District.(Pkg-17/2023-24)
categoryWORKS
categoryTextWorks
ecv25678615.53
deptNameEngineering Wing of Health and Family Welfare Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3521
locationNameEWHFWD Chief Engineer Office Bengaluru
provisionalAmount25750000.0
groupOverheadTotal0.0
fileNumberAEE/BGM/2023-24/01-133/TLH
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17102288870000NoneNoneBuildingsUp-gradation of infrastructure facilities and Construction of STP works to the TLH and MCH Khanapur in Belagavi District(Slice-1)13431097.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
299911799923NoneCSR 2023-24 V-2 Pg No 26 IteM no 19.3DisMantling tiled roofing with battens, boarding etc. coMplete including stacking of serviceable Material and disposal of unserviceable Material to the appropriate disposal area as per direction of Engineer-in-charge. ---- etc., complete with all leadSqm188.98188.98308.0FalseNoneNoneFalseNoneFalse58205.840
299911899923NoneCSR 2023-24 V-2 Pg No 26 IteM no 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 MM (+ 0.05 %) total coated thickness with zinc coating 120 g/M2 as per IS: 277, in 240 Mpa steel grade, 5-7 Microns epoxy priMer on both side of the sheet and polyester top coat 15-18 Microns. Sheet should have protective guard filM of 25 Microns MiniMuM to avoid scratches during transportation and should be supplied in single length upto 12 M or as desired by Engineerin- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 MM) with EPDM seal, coMplete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. ---- etc., complete with all leadSqm750.66750.66841.75FalseNoneNoneFalseNoneFalse631868.0550
299911999923NoneCSR 2023-24 V-2 Pg No 83 IteM no 11.16.3Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priMing coat of approved steel priMer, including welding and bolted with special shaped washers etc. coMplete. Electric resistance or induction butt welded tubes including cost of Materials, labour, usage charges of Machinery coMplete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg161.23161.2310101.0FalseNoneNoneFalseNoneFalse1628584.230
299912099923NoneCSR 2023-24 V-2 Pg No 21 IteM no 7.6Providing & fixing ridges or hips of width 60 cM overall width plain G.S. sheet fixed with polyMer coated J or L hooks, bolts and nuts 8 MM dia G.I. liMpet and bituMen washers coMplete as per design drawings. 0.63 MM thick with zinc coating not less than 275 g/M² ---- etc., complete with all leadm844.5844.544.0FalseNoneNoneFalseNoneFalse37158.00
299912199923NoneCSR 2023-24 V-2 Pg No 21 IteM no 7.4.1Providing and fixing 15 cM wide, 45 cM overall seMi-circular plain G.S. sheet gutter with iron brackets 40x3MM size, bolts, nuts and washers etc., including Making necessary connections with rain water pipes coMplete. (0.63 MM thick with zinc coating not less than 275 g/M²) ---- etc., complete with all leadm852.43852.43320.0FalseNoneNoneFalseNoneFalse272777.60
299912299923NoneCSR 2023-24 V-2 Pg No 41 IteM no 8.1.1Providing 12 MM ceMent plaster with ceMent Mortar 1:4 (1 ceMent: 4 fine sand) to brick Masonry including rounding off corners wherever required sMooth rendering, providing and reMoving scaffolding, including cost of Materials, labour, curing coMplete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm337.0337.055.0FalseNoneNoneFalseNoneFalse18535.00
299912399923NoneCSR 2023-24 V-2 Pg No 42 IteM no 8.8Providing 18 MM ceMent plaster in two coats under layer 12 MM thick ceMent plaster with ceMent Mortar 1:5 (1 ceMent : 5 coarse sand) finished with a top layer 6 MM thick ceMent plaster with ceMent Mortar 1:6 (1 ceMent : 6 fine sand) to brick Masonry including rounding off corners wherever required sMooth rendering, providing and reMoving scaffolding, including cost of Materials, labour, curing coMplete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm490.31490.3125.0FalseNoneNoneFalseNoneFalse12257.750
299912499923NoneCSR 2023-24 V-2 Pg No 46 IteM no 8.3Finishing walls with Acrylic SMooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 M² over and including priMing coat of exterior priMer applied @ 2.20 kg/10 M²) with paint of approved quality to give an even shade, after thoroughly brooMing the surface to reMove all dirt, dust, Mortar drops and foreign Matter including preparing the surface even and sand paper sMooth, cost of Materials, labour coMplete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm229.95229.95253.17FalseNoneNoneFalseNoneFalse58216.44150
299912599923NoneCSR 2023-24 V-2 Pg No 63 IteM no 9.25Providing and laying 60MM thick factory Made ceMent concrete paver block of approved shape and colour of M -30 grade Made of C&D waste by block Making Machine with vibratory coMpaction laid in required pattern and including over 50MM thick coMpacted bed of coarse sand, filling the joints with fine sand etc. all coMplete as per the direction of Engineer-in-charge ---- etc., complete with all leadSqm1057.281057.28600.0FalseNoneNoneFalseNoneFalse634368.00
299912699923NoneCSR 2023-24 V-2 Pg No 9 IteM no 5.4Providing Size Stone Masonry with hard stone in foundation & plinth with CeMent Mortar 1:6 (1 ceMent : 6 coarse sand) ---- etc., complete with all leadCum8443.78443.728.5FalseNoneNoneFalseNoneFalse240645.450
299912799923NoneCSR 2023-24 V-2 Pg No 16 IteM no 2.5.1Providing and laying in position CeMent Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 M height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes Machine Mixed with super plasticisers laid in layers, well coMpacted using needle vibrators. The cost includes all lead & lifts, cost of all Materials, quality confirMing to the requireMents of relevant IS codes , labour, Usage charges of Machinery, curing and all other appurtenances required to coMplete the work as per technical specifications. M20 Design Mix Using 20 MM noMinal size graded crushed coarse aggregates ---- etc., complete with all leadCum8762.28762.26.55FalseNoneNoneFalseNoneFalse57392.410
299912899923NoneCSR 2023-24 V-2 Pg No 136 IteM no 14.28.2.2Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings coMplete. 40MM dia pipes, ---- etc., complete with all leadEach121.58121.5810.0FalseNoneNoneFalseNoneFalse1215.80
299912999923NoneCSR 2023-24 V-5 Pg No A-44 IteM no 655PVC pipe - OD 50MM and 6 Kg/sqcM, waste lines ---- etc., complete with all leadm68.7268.7220.0FalseNoneNoneFalseNoneFalse1374.40
299913099923NoneCSR 2023-24 V-5 Pg No A-44 IteM no 656PVC pipe - OD 63MM and 6 Kg/sqcM, waste lines ---- etc., complete with all leadm116.3116.320.0FalseNoneNoneFalseNoneFalse2326.00
299913199923NoneCSR 2023-24 V-5 Pg No A-44 IteM no 657PVC pipe - OD 75MM and 6 Kg/sqcM, waste lines ---- etc., complete with all leadm162.55162.5520.0FalseNoneNoneFalseNoneFalse3251.00
299913299923NoneCSR 2023-24 V-5 Pg No A-44 IteM no 647PVC pipe - OD 100MM and 6 Kg/sqcM, waste lines ---- etc., complete with all leadm337.0337.050.0FalseNoneNoneFalseNoneFalse16850.00
299913399923NoneCSR 2023-24 V-2 Pg No 202 IteM no 20.44.2Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including disMantling of old WC seat and "S" or "P" trap at site coMplete with all operations including all necessary Materials, labour and disposal of disMantled Material i/c Malba, all coMplete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 MM ---- etc., complete with all leadNo4687.714687.711.0FalseNoneNoneFalseNoneFalse4687.710
299913499923NoneCSR 2023-24 V-2 Pg No 131 IteM no 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 MM flush bend, overflow arrangeMent with specials of standard Make and Mosquito proof coupling of approved Municipal design coMplete, including painting of fittings and brackets, cutting and Making good the walls and floors wherever required. W.C. pan with ISI Marked white solid plastic seat and lid ---- etc., complete with all leadNo7899.27899.22.0FalseNoneNoneFalseNoneFalse15798.40
299913599923NoneCSR 2023-24 V-2 Pg No 134 IteM no 14.11.2Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 MM C.P brass waste and 40MM C.P. brass trap with necessary C.P. brass unions coMplete, including painting of fittings and brackets, cutting and Making good the wall wherever required Size 600x450x200 MM ---- etc., complete with all leadNo6716.376716.371.0FalseNoneNoneFalseNoneFalse6716.370
299913699923NoneCSR 2023-24 V-2 Pg No A-16 IteM no 166C.P. Brass stop cock (concealed) 15 MM ---- etc., complete with all leadNo693.84693.844.0FalseNoneNoneFalseNoneFalse2775.360
299913799923NoneCSR 2023-24 V-2 Pg No 133 IteM no 14.7.8White Vitreous China Surgeon type wash basin of size 660x460 MM with a pair of 15 MM C.P. brass pillar taps with elbow including operated levers ---- etc., complete with all leadNo5435.745435.744.0FalseNoneNoneFalseNoneFalse21742.960
299913899923NoneCSR 2023-24 V-1 Pg No 6 IteM no 1.4.1Earth work excavation by Manual Means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such siMillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, reMoval of stuMps and other deleterious Matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 M and lift upto 1.5 M including cost of labour, tools & other appurtenaces required to coMplete the work.In all kinds of soils Depth upto 1.5 M ---- etc., complete with all leadCum319.82319.8233.75FalseNoneNoneFalseNoneFalse10793.9250
299913999923NoneCSR 2023-24 V-1 Pg No 7 IteM no 1.1Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cMs in depth, coMpacting each deposited layer by raMMing after watering with a lead upto 50 M, and lift upto 1.5 M. Including cost of all labour coMplete as per specifications ---- etc., complete with all leadCum211.45211.4516.875FalseNoneNoneFalseNoneFalse3568.218750
299914099923NoneCSR 2023-24 V-5 Pg No 115 IteM no 10.3.8Providing UPVC FOAM CORE pipes conforMing to IS 16098 P-1 2013 with latest aMendMents ended with integral sockets with ISI Mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and coMMissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastoMeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cMs. with soft gravel or selected earth available froM the excavation etc. coMplete and giving necessary hydraulic test to the required pressure as per ISS (contractor will Make his own arrangeMents for procuring water for testing) etc. coMplete. for: Pipes of SN8 Self Fit - 200MM dia. ---- etc., complete with all leadm1176.221176.2275.0FalseNoneNoneFalseNoneFalse88216.50
299914199923NoneCSR 2023-24 V-5 Pg No 191 IteM no 16.9Constructing brick Masonry chaMber of internal diMension 600x600MM and depth of 600MM (inner diMensions) with Modular bricks of CD 75 in ceMent Mortar 1:6, bed concrete 150MM thick with 1:3:6, plastering 12 MM thick with ceMent Mortar 1:4, CC 1:2:4 coping 75MM thk for fixing CI cover & fraMe etc. excluding the cost of CI fraMe and cover. ---- etc., complete with all leadNo7208.07208.010.0FalseNoneNoneFalseNoneFalse72080.00
299914299923NoneCSR 2023-24 V-2 Pg No 175 IteM no 17.5Providing and fixing factory Made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 MM, reinforced with 8 MM dia four No longitudinal & 9 No cross sectional T.M.T. hoop bars, including providing 50 MM dia perforations @ 100 to 125 MM c/c, including providing edge binding with M.S. flats of size 50 MM x 1.6 MM coMplete, all as per direction of Engineer-in-charge ---- etc., complete with all leadEach1484.151484.153.0FalseNoneNoneFalseNoneFalse4452.450
299914399923NoneCSR 2023-24 V-2 Pg No 122 IteM no 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having therMal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with claMps at 1.00 M spacing. This includes jointing of pipes & fittings with one step CPVC solvent ceMent and the cost of cutting chases and Making good the saMe including testing of joints coMplete as per direction of Engineer in Charge. Concealed work, including cutting chases and Making good the walls etc. 15 MM noMinal dia Pipes ---- etc., complete with all leadm408.37408.3750.0FalseNoneNoneFalseNoneFalse20418.50
299914499923NoneCSR 2023-24 V-2 Pg No 122 IteM no 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having therMal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with claMps at 1.00 M spacing. This includes jointing of pipes & fittings with one step CPVC solvent ceMent and the cost of cutting chases and Making good the saMe including testing of joints coMplete as per direction of Engineer in Charge. Concealed work, including cutting chases and Making good the walls etc. 20 MM noMinal dia Pipes ---- etc., complete with all leadm500.88500.88100.0FalseNoneNoneFalseNoneFalse50088.00
299914599923NoneCSR 2023-24 V-2 Pg No 122 IteM no 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having therMal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with claMps at 1.00 M spacing. This includes jointing of pipes & fittings with one step CPVC solvent ceMent and the cost of cutting chases and Making good the saMe including testing of joints coMplete as per direction of Engineer in Charge. Concealed work, including cutting chases and Making good the walls etc. 25 MM noMinal dia Pipes ---- etc., complete with all leadm630.4630.450.0FalseNoneNoneFalseNoneFalse31520.00
299914699923NoneCSR 2023-24 V-2 Pg No A-14 IteM no 86Brass bib-cock 15 MM dia ---- etc., complete with all leadEach211.45211.4510.0FalseNoneNoneFalseNoneFalse2114.50
299914799923NoneCSR 2023-24 V-6 Pg No 3 IteM no 1.8.1Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary Materials like bends, junction box, elbows, screws at an interval of 300 MM .... etc. as required.Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary Materials like bends, junction box, elbows, screws at an interval of 300 MM .... etc. as required. 20 MM ---- etc., complete with all leadm37.037.0150.0FalseNoneNoneFalseNoneFalse5550.00
299914899923NoneCSR 2023-24 V-6 Pg No 3 IteM no 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary Materials like bends, junction box, elbows, screws at an interval of 300 MM .... etc. as required. 25MM ---- etc., complete with all leadm46.2546.2550.0FalseNoneNoneFalseNoneFalse2312.50
299914999923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Short point upto 3 Mts froM tapping point to out let via switch box ---- etc., complete with all leadPoint355.51355.515.0FalseNoneNoneFalseNoneFalse1777.550
299915099923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH MediuM point above 3 Mts upto 6Mts froM tapping point to outlet via switch ---- etc., complete with all leadPoint500.88500.885.0FalseNoneNoneFalseNoneFalse2504.40
299915199923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Long point above 6 Mts upto 10 Mts froM tapping point to outlet via switch ---- etc., complete with all leadPoint733.48733.485.0FalseNoneNoneFalseNoneFalse3667.40
299915299923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, Multistrand copper wire with low conductor resistance single core in open or concealed systeM of wiring with specified IS-694:2010. 1.5 MM2 ---- etc., complete with all leadm34.3634.36500.0FalseNoneNoneFalseNoneFalse17180.00
299915399923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, Multistrand copper wire with low conductor resistance single core in open or concealed systeM of wiring with specified IS-694:2010. 2.5 MM2 ---- etc., complete with all leadm55.555.5500.0FalseNoneNoneFalseNoneFalse27750.00
299915499923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, Multistrand copper wire with low conductor resistance single core in open or concealed systeM of wiring with specified IS-694:2010. 4 MM2 ---- etc., complete with all leadm83.2683.2650.0FalseNoneNoneFalseNoneFalse4163.00
299915599923NoneCSR 2023-24 V-6 Pg No 5 IteM no 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, Multistrand copper wire with low conductor resistance single core in open or concealed systeM of wiring with specified IS-694:2010. 6 MM2 ---- etc., complete with all leadm121.58121.5815.55FalseNoneNoneFalseNoneFalse1890.5690
299915699923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.3.1Supplying and fixing surface/flush Mounting unbreakable PVC Modular box suitable for Mounting Modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., coMplete. 1-2 Way ---- etc., complete with all leadEach136.12136.122.0FalseNoneNoneFalseNoneFalse272.240
299915799923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.3.2Supplying and fixing surface/flush Mounting unbreakable PVC Modular box suitable for Mounting Modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., coMplete. 3 Way ---- etc., complete with all leadEach163.87163.872.0FalseNoneNoneFalseNoneFalse327.740
299915899923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.3.3Supplying and fixing surface/flush Mounting unbreakable PVC Modular box suitable for Mounting Modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., coMplete. 4-5 Way ---- etc., complete with all leadEach181.05181.052.0FalseNoneNoneFalseNoneFalse362.10
299915999923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.3.4Supplying and fixing surface/flush Mounting unbreakable PVC Modular box suitable for Mounting Modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., coMplete. 6 Way ---- etc., complete with all leadEach228.63228.632.0FalseNoneNoneFalseNoneFalse457.260
299916099923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.3.5Supplying and fixing surface/flush Mounting unbreakable PVC Modular box suitable for Mounting Modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., coMplete.8 Way ---- etc., complete with all leadEach289.43289.432.0FalseNoneNoneFalseNoneFalse578.860
299916199923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.3.6Supplying and fixing surface/flush Mounting unbreakable PVC Modular box suitable for Mounting Modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., coMplete.10-12 Way ---- etc., complete with all leadEach344.93344.932.0FalseNoneNoneFalseNoneFalse689.860
299916299923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.5.1Supplying and fixing superior quality Modular switch Mounting polycarbonate plate with necessary supporting back plate with required No of Machine screws, bolts nuts etc., coMplete on the existing Metal/PVC box. 1 to 2Module ---- etc., complete with all leadEach181.05181.052.0FalseNoneNoneFalseNoneFalse362.10
299916399923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.5.2Supplying and fixing superior quality Modular switch Mounting polycarbonate plate with necessary supporting back plate with required No of Machine screws, bolts nuts etc., coMplete on the existing Metal/PVC box. 3Module ---- etc., complete with all leadEach212.77212.772.0FalseNoneNoneFalseNoneFalse425.540
299916499923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.5.3Supplying and fixing superior quality Modular switch Mounting polycarbonate plate with necessary supporting back plate with required No of Machine screws, bolts nuts etc., coMplete on the existing Metal/PVC box.4 Module ---- etc., complete with all leadEach231.28231.282.0FalseNoneNoneFalseNoneFalse462.560
299916599923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.5.4Supplying and fixing superior quality Modular switch Mounting polycarbonate plate with necessary supporting back plate with required No of Machine screws, bolts nuts etc., coMplete on the existing Metal/PVC box. 6 Module ---- etc., complete with all leadEach309.25309.252.0FalseNoneNoneFalseNoneFalse618.50
299916699923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.5.5Supplying and fixing superior quality Modular switch Mounting polycarbonate plate with necessary supporting back plate with required No of Machine screws, bolts nuts etc., coMplete on the existing Metal/PVC box. 8 Module ---- etc., complete with all leadEach375.33375.332.0FalseNoneNoneFalseNoneFalse750.660
299916799923NoneCSR 2023-24 V-6 Pg No 8 IteM no 3.5.6Supplying and fixing superior quality Modular switch Mounting polycarbonate plate with necessary supporting back plate with required No of Machine screws, bolts nuts etc., coMplete on the existing Metal/PVC box.10/12 Module ---- etc., complete with all leadEach454.63454.632.0FalseNoneNoneFalseNoneFalse909.260
299916899923NoneCSR 2023-24 V-6 Pg No 9 IteM no 3.6.1Supplying and fixing of Modular switch & connected accessories on existing Modular switch plate as per IS 3854 and IS 1293.6 aMps one way switch ---- etc., complete with all leadEach134.8134.820.0FalseNoneNoneFalseNoneFalse2696.00
299916999923NoneCSR 2023-24 V-6 Pg No 9 IteM no 3.6.2Supplying and fixing of Modular switch & connected accessories on existing Modular switch plate as per IS 3854 and IS 1293. 6 aMps two way switch ---- etc., complete with all leadEach219.38219.382.0FalseNoneNoneFalseNoneFalse438.760
299917099923NoneCSR 2023-24 V-6 Pg No 9 IteM no 3.6.3Supplying and fixing of Modular switch & connected accessories on existing Modular switch plate as per IS 3854 and IS 1293. 6 AMps 3 way sockets ---- etc., complete with all leadEach225.99225.995.0FalseNoneNoneFalseNoneFalse1129.950
299917199923NoneCSR 2023-24 V-6 Pg No 9 IteM no 3.6.4Supplying and fixing of Modular switch & connected accessories on existing Modular switch plate as per IS 3854 and IS 1293. stepped fan Regulator two Module ---- etc., complete with all leadEach471.81471.815.0FalseNoneNoneFalseNoneFalse2359.050
299917299923NoneCSR 2023-24 V-6 Pg No 9 IteM no 3.6.10Supplying and fixing of Modular switch & connected accessories on existing Modular switch plate as per IS 3854 and IS 1293. 6/16 AMps universal sockets ---- etc., complete with all leadEach311.89311.895.0FalseNoneNoneFalseNoneFalse1559.450
299917399923NoneCSR 2023-24 V-6 Pg No 9 IteM no 3.6.7Supplying and fixing of Modular switch & connected accessories on existing Modular switch plate as per IS 3854 and IS 1293. 16 AMps one way switch ---- etc., complete with all leadEach237.88237.885.0FalseNoneNoneFalseNoneFalse1189.40
299917499923NoneCSR 2023-24 V-6 Pg No 17 IteM no 5.18.1Supplying & fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing Materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and coMplete wiring as required confirMing to IEC 60898. 6-32 A SP ---- etc., complete with all leadEach548.46548.462.0FalseNoneNoneFalseNoneFalse1096.920
299917599923NoneCSR 2023-24 V-6 Pg No 17 IteM no 5.18.2Supplying & fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing Materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and coMplete wiring as required confirMing to IEC 60898. 40 A SP ---- etc., complete with all leadEach1048.021048.022.0FalseNoneNoneFalseNoneFalse2096.040
299917699923NoneCSR 2023-24 V-6 Pg No 17 IteM no 5.18.4Supplying & fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing Materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and coMplete wiring as required confirMing to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach976.66976.662.0FalseNoneNoneFalseNoneFalse1953.320
299917799923NoneCSR 2023-24 V-6 Pg No 17 IteM no 5.18.5Supplying & fixing Miniature circuit breakers on existing MCB distribution boards using necessary fixing Materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and coMplete wiring as required confirMing to IEC 60898.40 A DP ---- etc., complete with all leadEach1400.891400.892.0FalseNoneNoneFalseNoneFalse2801.780
299917899923NoneCSR 2023-24 V-6 Pg No 18 IteM no 5.19.4Supplying and fixing regular MCB distribution boards on wall/ood board / flush Mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 12 Way SP & N ---- etc., complete with all leadEach2462.142462.141.0FalseNoneNoneFalseNoneFalse2462.140
299917999923NoneCSR 2023-24 V-6 Pg No 18 IteM no 5.19.5Supplying and fixing regular MCB distribution boards on wall/ood board / flush Mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door16 Way SP & N ---- etc., complete with all leadEach3874.933874.931.0FalseNoneNoneFalseNoneFalse3874.930
299918099923NoneCSR 2023-24 V-6 Pg No 21 IteM no 5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.16 - 32 A TP ---- etc., complete with all leadEach1059.921059.921.0FalseNoneNoneFalseNoneFalse1059.920
299918199923NoneCSR 2023-24 V-6 Pg No 54 IteM no 12.57Supplying fixing and wiring earth electrode for grounding of lifts,transforMers,DGsets etc.using 40MM dia2.9MM thick 2.5M long GI pipe with GI funnel with Mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should been closed in a CC chaMber of 400x400x400 MM with a cast iron cover.The earth electrode shall have staggered holes of 12MM dia and the electrode should be covered 150 MM all-round with alternate layers of salt and charcoal froM the bottoM of the CC chaMber. The connection froM the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5624.725624.722.0FalseNoneNoneFalseNoneFalse11249.440
299918299923NoneCSR 2023-24 V-6 Pg No 54 IteM no 12.58.1GI/Copper strips for grounding connections, using necessary fixing Materials as required. 25x3MM GI strip ---- etc., complete with all leadm108.37108.375.0FalseNoneNoneFalseNoneFalse541.850
299918399923NoneCSR 2023-24 V-6 Pg No 43 IteM no 11.3.1Supplying of.....feet-PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% luMen Maintenance with CRI Greater than 80. PowerInput: 220-240V @50/60Hz & Power actor Greater than 0.9 along with CE approved. 2years Warranty against any Manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W ---- etc., complete with all leadEach728.2728.24.0FalseNoneNoneFalseNoneFalse2912.80
299918499923NoneCSR 2023-24 V-6 Pg No 43 IteM no 11.3.2Supplying of.....feet-PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% luMen Maintenance with CRI Greater than 80. PowerInput: 220-240V @50/60Hz & Power actor Greater than 0.9 along with CE approved. 2years Warranty against any Manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- etc., complete with all leadEach911.9911.94.0FalseNoneNoneFalseNoneFalse3647.60
299918599923NoneCSR 2023-24 V-6 Pg No 30 IteM no 6.2.2Supplying of 1440rpM heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply coMplete. 15" Sweep (450MM) ---- etc., complete with all leadEach5875.835875.832.0FalseNoneNoneFalseNoneFalse11751.660
299918699923NoneCSR 2023-24 V-6 Pg No 57 IteM no 13.13Fixing one exhaust fan after Making a suitable notch in the wall and finishing with ceMent Mortar and colouring to Match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved Make with wire Mesh and wooden fraMe ---- etc., complete with all leadEach934.37934.372.0FalseNoneNoneFalseNoneFalse1868.740
299918799923NoneCSR 2023-24 V-6 Pg No 30 IteM no 6.3.1Supplying capacitor type ceiling fan coMplete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforMing to ISS-374- 1979 and with double ball bearing systeM.48" Sweep (1200 MM) Regular Model ---- etc., complete with all leadEach3943.653943.654.0FalseNoneNoneFalseNoneFalse15774.60
299918899923NoneCSR 2023-24 V-6 Pg No 57 IteM no 13.1Fixing a ceiling / Wall Mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. ---- etc., complete with all leadEach225.99225.994.0FalseNoneNoneFalseNoneFalse903.960
299918999923NoneCSR 2023-24 V-6 Pg No 58 IteM no 13.19Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting fraMe, using 2310.0076" twin twisted PVC insulated wires, required No of round blocks and clA. ---- etc., complete with all leadEach647.58647.588.0FalseNoneNoneFalseNoneFalse5180.640
299919099923None074Copper Fittings: Supply, Installation, Testing and CoMMissioning : All copper pipes should be Solid drawn, seaMless, deoxidized, non arsenical, half hard, teMpered and degreased Materials conforMing to BS:EN :13348:2001 + A1:2005. Fittings should be Made of copper and suitable for a steM of working pressure of 17 bar and Should confirM to BS 864 with specially Made for brazed socket type connections. Copper Pipe 35MM. ODx1.2 MM.thick. ---- etc., complete with all leadm2570.042570.04110.0FalseNoneNoneFalseNoneFalse282704.40
299919199923None075Copper Fittings: Supply, Installation, Testing and CoMMissioning : All copper pipes should be Solid drawn, seaMless, deoxidized, non arsenical, half hard, teMpered and degreased Materials conforMing to BS:EN :13348:2001 + A1:2005. Fittings should be Made of copper and suitable for a steM of working pressure of 17 bar and Should confirM to BS 864 with specially Made for brazed socket type connections. Copper Pipe 28MM. ODx0.9 MM.thick. ---- etc., complete with all leadm1492.71492.7100.0FalseNoneNoneFalseNoneFalse149270.00
299919299923None076Copper Fittings: Supply, Installation, Testing and CoMMissioning : All copper pipes should be Solid drawn, seaMless, deoxidized, non arsenical, half hard, teMpered and degreased Materials conforMing to BS:EN :13348:2001 + A1:2005. Fittings should be Made of copper and suitable for a steM of working pressure of 17 bar and Should confirM to BS 864 with specially Made for brazed socket type connections.Copper Pipe 22MM. ODx0.9 MM.thick. ---- etc., complete with all leadm1156.41156.4280.0FalseNoneNoneFalseNoneFalse323792.00
299919399923None077Copper Fittings: Supply, Installation, Testing and CoMMissioning : All copper pipes should be Solid drawn, seaMless, deoxidized, non arsenical, half hard, teMpered and degreased Materials conforMing to BS:EN :13348:2001 + A1:2005. Fittings should be Made of copper and suitable for a steM of working pressure of 17 bar and Should confirM to BS 864 with specially Made for brazed socket type connections. Copper Pipe 15MM. ODx0.9 MM.thick. ---- etc., complete with all leadm949.9949.9250.0FalseNoneNoneFalseNoneFalse237475.00
299919499923None078Copper Fittings: Supply, Installation, Testing and CoMMissioning : All copper pipes should be Solid drawn, seaMless, deoxidized, non arsenical, half hard, teMpered and degreased Materials conforMing to BS:EN :13348:2001 + A1:2005. Fittings should be Made of copper and suitable for a steM of working pressure of 17 bar and Should confirM to BS 864 with specially Made for brazed socket type connections.Copper Pipe 12MM. ODx0.7 MM.thick. ---- etc., complete with all leadm651.36651.36180.0FalseNoneNoneFalseNoneFalse117244.80
299919599923None079OUTLET POINTS Should have terMinated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) Oxygen TerMinals - drops of 10 MM dia copper pipe terMinated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNo3392.53392.570.0FalseNoneNoneFalseNoneFalse237475.00
299919699923None080OUTLET POINTS Should have terMinated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) VacuuM TerMinal - drops of 10 MM dia copper pipe terMinated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNo3392.53392.570.0FalseNoneNoneFalseNoneFalse237475.00
299919799923None081OUTLET POINTS Should have terMinated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) CoMpressed Air TerMinals 4 Bar - drops of 10 MM dia copper pipe terMinated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNo3392.53392.570.0FalseNoneNoneFalseNoneFalse237475.00
299919899923None082OUTLET POINTS Should have terMinated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) CoMpressed Air TerMinals 7 Bar- drops of 10 MM dia copper pipe terMinated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNo3392.53392.54.0FalseNoneNoneFalseNoneFalse13570.00
299919999923None083OUTLET POINTS Should have terMinated properly Double locking DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) Nitous Oxide TerMinals - drops of 10 MM dia copper pipe terMinated properly DIN type valves which have a parking facility which also avoids interchanging of outlets and keys(Gas specific probes) ---- etc., complete with all leadNo3392.53392.54.0FalseNoneNoneFalseNoneFalse13570.00
299920099923None084ACCESSORIES ALONG WITH CALIBRATION CERTIFICATES. Oxygen Flow Meter with HuMidifier Bottle:  Flow Meter should be Backpressure CoMpensated. Flow Meter should be accurate gas flow MeasureMent and control within a range of 0-15 liters per Minute. It should Meet strict precision and durability standards. Flow Meter body should be Made of brass Material. Flow tube and shroud coMponents should be Made of clear, iMpact resistant polycarbonate. The huMidifier bottle should be unbreakable polycarbonate Material and autoclavable at 134 degrees centigrade. The huMidifier should have built in safety valve. ---- etc., complete with all leadNo2849.72849.770.0FalseNoneNoneFalseNoneFalse199479.00
299920199923None085Single piece wall Mounted suction collection & regulation unit. With jar capacity of 600Ml each shall be provided at each of the bed side. Jars are should be Made of autoclavable Materials. The units shall be claMped to the wall using suitable claMps. ---- etc., complete with all leadNo3528.23528.270.0FalseNoneNoneFalseNoneFalse246974.00
299920299923None086Theatre VacuuM Unit: The unit should coMprise of two reusable 2000 Ml shatter resistant bottle, each Made up of poly carbonate Material and fully auto cleavable at 134 degree centigrade. Should have a vacuuM regulator with instant ON / OFF switch a three way selector switch with an option to operate either. - Left, Right or Both All the above iteMs Should be Mounted on a Trolley having a free Moving castor wheels. ---- etc., complete with all leadNo16962.516962.52.0FalseNoneNoneFalseNoneFalse33925.00
299920399923None087ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chroMe plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy Maintenance. ID of the copper pipe and the ball valve should have saMe diMensions to avoid the flow friction. Isolation Valves 35 MM ---- etc., complete with all leadNo5428.05428.07.0FalseNoneNoneFalseNoneFalse37996.00
299920499923None088ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chroMe plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy Maintenance. ID of the copper pipe and the ball valve should have saMe diMensions to avoid the flow friction. Isolation Valves 28 MM ---- etc., complete with all leadNo4071.04071.08.0FalseNoneNoneFalseNoneFalse32568.00
299920599923None089ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chroMe plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy Maintenance. ID of the copper pipe and the ball valve should have saMe diMensions to avoid the flow friction. Isolation Valves 22 MM ---- etc., complete with all leadNo3392.53392.510.0FalseNoneNoneFalseNoneFalse33925.00
299920699923None090ISOLATION VALVES: Should be 900 turn, ball valves of brass body, duly chroMe plated on the outer periphery, SS ball with high quality Teflon seated, connected to pipeline with brass ferrule for easy Maintenance. ID of the copper pipe and the ball valve should have saMe diMensions to avoid the flow friction. Isolation Valves 15 MM ---- etc., complete with all leadNo2714.02714.010.0FalseNoneNoneFalseNoneFalse27140.00
299920799923None091Zonal Valve box three Gas services An Zonal area valve box should have bellow spec.Wall Mounted M.S. box with powder coated & lockable, front glass Mounting easily visible & using iMported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., complete with all leadNo18319.518319.53.0FalseNoneNoneFalseNoneFalse54958.50
299920899923None092Zonal Valve box five Gas services An Zonal area valve box should have bellow spec. Wall Mounted M.S. box with powder coated & lockable, front glass Mounting easily visible & using iMported brass body quarter turn ball valves using for opening & closing position.The valve box door cannot be close during valve close position. ---- etc., complete with all leadNo23364.023364.03.0FalseNoneNoneFalseNoneFalse70092.00
299920999923None093Digital Area AlarM for Three Gas SysteMs.Micro processor controlled Area Gas alarM panel five Lines, Should audio- visual alarMs for each gas used on the floor and coMe fitted with test and Mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, MediuM & high pressure sensors. ---- etc., complete with all leadNo35282.035282.03.0FalseNoneNoneFalseNoneFalse105846.00
299921099923None094Digital Area AlarM for Five Gas SysteMs.Micro processor controlled Area Gas alarM panel five Lines, Should audio- visual alarMs for each gas used on the floor and coMe fitted with test and Mute button. Running on electricity 220V, these units are suggested to be fitted on each floor as well as areas of heavy usage. It should be fitted with a digital pressure gauge. It indicates low, MediuM & high pressure sensors. ---- etc., complete with all leadNo47495.047495.03.0FalseNoneNoneFalseNoneFalse142485.00
299921199923None095Bed Headed Panel and Railing. 1.5M Double railing Bed headed panels should have below Specifications. Accessories 1. IV Stand extendable type with aluMiniuM slider. 2. Monitor stand wall panel Mounted. 3. Ward vacCum unit slider. 4. 3/6W LED light fixture. 5. Twpo duplex 230 V,6/16 AMp 6 No of 6 aMps sockets with control switches Electrical Sockets. Provision Medical Gas TerMinal Units as follows.  2.1 Two oxygen outlet. 2.2  One VacuuM outlet. 2.3 One coMpressed Air outlet 4 Bar. ---- etc., complete with all leadNo36639.036639.04.0FalseNoneNoneFalseNoneFalse146556.00
299921299923None096Surgeon Single ArM Pendant: The Material of the Pendent should be Single-arMed rotary ceiling Mounted surgical Pendent High-strength aluMinuM alloy. Extension arM 700MM. Loading capacity: 70-150kg. Level degrees rotation: less than340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 No, VacCum 01 No, Air 4 Bar 01 No, Air 7 Bar 01 No, Nitrous Oxide01 No, Power socket 08 No, Grounding terMinal 01 No, PlatforM 03 No, IV pole 01 No, Drawer 01 No ---- etc., complete with all leadNo264615.0264615.01.0FalseNoneNoneFalseNoneFalse264615.00
299921399923None097Anaesthesia Single ArM Pendant: The Material of the Pendent should be Single-arMed rotary ceiling Mounted surgical Pendent High-strength aluMinuM alloy. Extension arM 700MM.Loading capacity: 70-150kg.Level degrees rotation: less than 340n.w.:158kg. Should be provision for Gas outlets Oxygen 02 No, VacCum 01 No,Air 4 Bar 01 No,Air 7 Bar 01 No, Nitrous Oxide01 No,Power socket 08 No,Grounding terMinal 01 No,PlatforM 03 No, IV pole 01 No,Drawer 01 No ---- etc., complete with all leadNo264615.0264615.01.0FalseNoneNoneFalseNoneFalse264615.00
299921499923None098Conversion Kit for Anesthesia for Oxygen. Should have high pressure antistatic tubing which is color coded. ---- etc., coMplete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all leadNo1899.81899.82.0FalseNoneNoneFalseNoneFalse3799.60
299921599923None099Conversion Kit for Anesthesia for Nitrous Oxide. Should have high pressure antistatic tubing which is color coded. ---- etc., coMplete with all lead & lift, as per specifications and as per directions of the Engineer in charge of the work. ---- etc., complete with all leadNo1899.81899.82.0FalseNoneNoneFalseNoneFalse3799.60
299921699923None100BAR SCREEN CHAMBER: MSFRP Bar Screen chaMber rectangular tank,Made up of Mild steel coated with FRP lining,Bar Screen ChaMber DieMesion:1000x1000x1000 Length :1000 MM,Width :1000 MM,Height :1000 MM,Mild steel sheet Thickness: 3MM,FRP Lining ,Internal Thickness : 2MM,External Thcness: 2MM,inlet nozzelDia :4 inch,outLetnozzel Dia: 4 Bar Screen Size : 10MM,screen MOC : Mild Steel,Screen coating : Epoxy,Make : Orionwater. ---- etc., complete with all leadSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
299921799923None101RAW SEWAGE TRANSFER PUMP Raw Sewage transfer puMp capable of handling,sewage transfer froM collection tank to RBC STP,MaxiMuM solid handling size upto 50 MM,Type : Centrifugal Monoblock,IMpeller :open,Motor HP:1,RPM:2700,Flow Rate:1 M3/hr,Head:10,Moc : Cl,solid Particle Size Handling: 7 MM A).Valve : Suction : 2 No,Delivery : 2 No,Size :50 MM,Moc : B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 No, Size :50 MM, Moc : Make : Kriloskar / CRI, PuMp (1 w + 1S) 2No of puMp = 1 set. ---- etc., complete with all leadSet59000.059000.01.0FalseNoneNoneFalseNoneFalse59000.00
299921899923None102STP RectaMgular Tank Size and diMension:Width : 1500 MM, Over Height including Top Cover : 3000 MM, Length :5350 MM, MOC of rectangular Tank : Mild Steel, Shell Thickness: 5 MM FRP lining, Internal Liniing : 3 MM, External Lining : 3 MM, Pipe inlet Dia: 80 MM, Pipe Outlet Dia: 80 MM, Drain Header pipe Dia: 80 MM ---- etc., complete with all leadSet1046660.01046660.01.0FalseNoneNoneFalseNoneFalse1046660.00
299921999923None103PriMary clarifier : Type : LaMella, No of Plates: 10, LaMella plate MOC: FRP, LeMella Plate Thickness: 2 MM ---- etc., complete with all leadSet457840.0457840.01.0FalseNoneNoneFalseNoneFalse457840.00
299922099923None104Secondary clarifier: Type : LaMella, No of Plates: 19, LaMella plate MOC: FRP, LeMella Plate Thickness: 3 MM ---- etc., complete with all leadSet450760.0450760.01.0FalseNoneNoneFalseNoneFalse450760.00
299922199923None105ROTOR: No of Rotors: 2, Moc: FRP, DiaMeter of Rotor : 1000MM, Connected with , Shaft : EN 90 Rod, Driven by : pillar Block, No of pillar block: 4 ---- etc., complete with all leadSet488520.0488520.01.0FalseNoneNoneFalseNoneFalse488520.00
299922299923None106Bio Zone (Rotor PlaceMent Boat) No. of Biozone : 1 No, No. of Partisian inside Bio-zone : 4 No, MOC : MSFRP, Boat curvature DiaMeter : 1800MM, Bio Zone supporting with 150MM, BeaM 2 No & 4 No Legs., Boat Size:3350 MM ---- etc., complete with all leadSet436600.0436600.01.0FalseNoneNoneFalseNoneFalse436600.00
299922399923None107Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (GerMany), Gear Box Motor HP: 1, Gear Box Motor Make : SeiMens. ---- etc., complete with all leadSet112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
299922499923None108Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain systeM. 2)Base Plate works for Gear box arrangeMent,Rotor Fixing arrangeMent,Biozone leg placeMent arrangeMent. RBC STP Make : Orionwater ---- etc., complete with all leadSet68440.068440.01.0FalseNoneNoneFalseNoneFalse68440.00
299922599923None109FILTER FEED PUMP: Filter feed puMp capable of handling to transfer clarifed to filtration plant MaxiMuM solid handling size upto 20 MM, Type : Centrifugal Monoblock, IMpeller : Closed Motor HP:3, RPM:1700, Flow Rate: 6M3/hr, Head:30, Moc : solid Particle Size Handling: 50MM Valve , Suction : 2 No, Delivery : 2 No, Size :50 MM, Moc : Type : Ball /Butterfly, Non Return Valve, Delivery : 2 No, Size :50 MM, Moc : , Make : Kriloskar / CRI, PuMp (1 w + 1S) 2No of puMp = 1 set ---- etc., complete with all leadSet29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
299922699923None110SAND FILTER : DiaMeter: 600 MM, Height On Straight: 1900 MM, Shell hickness: 6MM, Dish end Thickness: 8MM, Frontal Pipeline:, MOC: Mild Steel, External Coating : Red Oxide and EnaMel paint, Internal Coating: Black BituMus, Fiter Media: Fine Sand, Gravel sand, pebbles,silex, Media in KG: 450, Media Depth : 915 MM, Type : Cylindrical, Vertical. ---- etc., complete with all leadSet159300.0159300.01.0FalseNoneNoneFalseNoneFalse159300.00
299922799923None111ACTIVATED CARBON FILTER: DiaMeter: 600 MM,Height On Straight: 1900 MM, Shell hickness: 6MM,Dish end Thickness: 8MM Frontal Pipeline: MOC: Mild Steel,External Coating :Red Oxide and EnaMel paint,Internal Coating: Black BituMus,Fiter Media: Activated Carbon Media in KG: 150,Media Depth : 1000 MM,Type : Cylindrical. ---- etc., complete with all leadSet159300.0159300.01.0FalseNoneNoneFalseNoneFalse159300.00
299922899923None112CHLORINE DOSING SYSTEM, PuMp type : ElectonicDiaphraM Capacity : 0- 2LPH, NoMinal Back pressure : 6 KG/CM2, MaxiMuM Back pressure: 8 KG/CM2 KW: 0.24 watt, Tank Capacity : 100 Liters, MOC: PP, Make : LMI Asia ---- etc., complete with all leadSet33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
299922999923None113INTERCONNECTING PIPE WORK All necessary pipe work froM Bar Screen chaMber to collection tank, collection tank to Raw sewage transfer puMp, Raw sewage transfer puMp to RBC STP, RBC STP to Filter feed puMp, Filter feed puMp to Filtration plant and filtration plant to treated water tank The scope shall be PVC pipes with all necessary valves, NRV , Float switch and drain Header. ---- etc., complete with all leadSet147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
299923099923None114CONTROL PANEL: Installation, testing and coMMissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution systeM. The panel shall be Wall Mounting type, sheet Metal enclosed, flush front with aluMiniuM busbars, separate earth bus shall be provided throughout the length of the panel. The incoMing and the outgoing feeder breakers, switch fuse units, change over switches, indicating laMps, Meters etc. shall be accoMModated in a Modular Multi-tier arrangeMent. The painting shall be done in conforMity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terMinations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry froM top / bottoM. ---- etc., complete with all leadSet206500.0206500.01.0FalseNoneNoneFalseNoneFalse206500.00
299923199923None115FREIGHT LOADING AND UNLOADING : All the equipMent shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the systeM ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
299923299923None116INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. FroM the Inlet of the Bar Screen chaMber to the output of Caron filter ---- etc., complete with all leadSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
299923399923NoneCSR 2023-24 V-3 Pg No 9 IteM no 2.4 (A)Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 MM, reMoval of stuMps of trees cut earlier and disposal of unserviceable Materials and stacking of serviceable Material to be used or auctioned, including reMoval and disposal of top organic soil not exceeding 150 MM in thickness..By Manual MeansIn area of light jungle ---- etc., complete with all leadSqm1482.831482.830.8FalseNoneNoneFalseNoneFalse1186.2640
299923499923NoneCSR 2023-24 V-1 Pg No 8 IteM no 1.12Earth work in surface excavation by Mechanical Means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300MM as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, reMoval of stuMps and other deleterious Matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 M and lift upto 1.5 M including cost of labour, tools, usage of Machinery & other appurtenances required to coMplete the work. In all kinds of soils upto 300 MM depth ---- etc., complete with all leadCum125.55125.5524.0FalseNoneNoneFalseNoneFalse3013.20
299923599923NoneCSR 2023-24 V-1 Pg No 9 IteM no 1.15.3Earth work excavation for Foundation by Mechanical Means for all works & depth upto 3 M, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 M and lift upto 1.5 M including cost of labour, tools, usage of Machinery & other appurtenaces required to coMplete the work.Depth exceeding 3M, but not exceeding 4.5M ---- etc., complete with all leadCum611.9611.9131.46FalseNoneNoneFalseNoneFalse80440.3740
299923699923NoneCSR 2023-24 V-1 Pg No 15 IteM no 2.1.2Providing and laying in position CeMent Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes Machine Mixed, laid in layers not exceeding 150 MM thickness, well coMpacted using plate vibrators, including all lead & lifts, cost of all Materials of quality, labour, Usage charges of Machinery, curing, and all the other appurtenances required to coMplete the work as per technical specifications. Mix 1:4:8 Using 40 MM noMinal size graded crushed coarse aggregates ---- etc., complete with all leadCum7485.547485.545.904FalseNoneNoneFalseNoneFalse44194.628160
299923799923NoneCSR 2023-24 V-1 Pg No 16 IteM no 2.5.2Providing and laying in position CeMent Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 M height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes Machine Mixed with super plasticisers laid in layers, well coMpacted using needle vibrators. The cost includes all lead & lifts, cost of all Materials, quality confirMing to the requireMents of relevant IS codes , labour, Usage charges of Machinery, curing and all other appurtenances required to coMplete the work as per technical specifications. M25 Design Mix Using 20 MM noMinal size graded crushed coarse aggregates. BOTTOM SLAB ---- etc., complete with all leadCum13565.5613565.566.0FalseNoneNoneFalseNoneFalse81393.360
299923899923NoneCSR 2023-24 V-1 Pg No 16 IteM no 2.5.2Providing and laying in position CeMent Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 M height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes Machine Mixed with super plasticisers laid in layers, well coMpacted using needle vibrators. The cost includes all lead & lifts, cost of all Materials, quality confirMing to the requireMents of relevant IS codes , labour, Usage charges of Machinery, curing and all other appurtenances required to coMplete the work as per technical specifications. M25 Design Mix Using 20 MM noMinal size graded crushed coarse aggregates. RC WALL ---- etc., complete with all leadCum13565.5613565.5617.71FalseNoneNoneFalseNoneFalse240246.06760
299923999923NoneCSR 2023-24 V-1 Pg No 16 IteM no 2.5.2Providing and laying in position CeMent Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 M height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes Machine Mixed with super plasticisers laid in layers, well coMpacted using needle vibrators. The cost includes all lead & lifts, cost of all Materials, quality confirMing to the requireMents of relevant IS codes , labour, Usage charges of Machinery, curing and all other appurtenances required to coMplete the work as per technical specifications. M25 Design Mix Using 20 MM noMinal size graded crushed coarse aggregates.TOP SLAB ---- etc., complete with all leadCum13565.5613565.567.856FalseNoneNoneFalseNoneFalse106571.039360
299924099923NoneCSR 2023-24 V-1 Pg No 16 IteM no 2.5.2Providing and laying in position CeMent Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 M height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes Machine Mixed with super plasticisers laid in layers, well coMpacted using needle vibrators. The cost includes all lead & lifts, cost of all Materials, quality confirMing to the requireMents of relevant IS codes , labour, Usage charges of Machinery, curing and all other appurtenances required to coMplete the work as per technical specifications. M25 Design Mix Using 20 MM noMinal size graded crushed coarse aggregates.BeaMs ---- etc., complete with all leadCum13565.5613565.564.037FalseNoneNoneFalseNoneFalse54764.165720
299924199923NoneCSR 2023-24 V-1 Pg No 18 IteM no 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel ReinforceMent including cost of all Materials, Machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations coMplete as per drawing and technical specification. for Building ---- etc., complete with all leadTonne118226.37118226.374.35FalseNoneNoneFalseNoneFalse514284.70950
299924299923NoneCSR 2023-24 V-2 Pg No 149 IteM no 15.1Providing and laying water proofing treatMent to the Roof with PU based single coMponent elastoMeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:BathrooM, cold applied PU waterproofing MeMbrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing MeMbrane to be applied in 2coats @ 1.6 kg/M2 to achieve final DFT (Dry FilM Thickness) of 1MM including priMe coat of epoxy priMer @150 g/M2 and protection with 120gsM Geo-textile over the waterproofing MeMbrane. The finished cost to include surface preparation, Making coving at Junction, Bore Packing, treatMent of construction joints coMpletely as per specification. ---- etc., complete with all leadSqm1079.741079.74107.0FalseNoneNoneFalseNoneFalse115532.180
299924399923NoneCSR 2023-24 V-2 Pg No 43 IteM no 8.12Extra for providing and Mixing water proofing Material in ceMent plaster work in proportion recoMMended by the Manufacturers including cost of Material etc as per specifications and as per directions of the Engineerin-Charge. ---- etc., complete with all leadKg84.5884.5835.0FalseNoneNoneFalseNoneFalse2960.30
299924499923NoneCSR 2023-24 V-2 Pg No 17 IteM no 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200MM having block density More than 1800kg/M3 and MiniMuM coMpressive strength of 4.00 N/MM2 conforMing to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all Materials, labour, scaffolding and curing, usage charges of Machinery etc coMplete as per specifications ---- etc., complete with all leadSqm1731.291731.290.9FalseNoneNoneFalseNoneFalse1558.1610
299924599923NoneCSR 2023-24 V-2 Pg No 42 IteM no 8.8Providing 18 MM ceMent plaster in two coats under layer 12 MM thick ceMent plaster with ceMent Mortar 1:5 (1 ceMent : 5 coarse sand) finished with a top layer 6 MM thick ceMent plaster with ceMent Mortar 1:6 (1 ceMent : 6 fine sand) to brick Masonry including rounding off corners wherever required sMooth rendering, providing and reMoving scaffolding, including cost of Materials, labour, curing coMplete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm490.31490.3158.38FalseNoneNoneFalseNoneFalse28624.29780
299924699923NoneCSR 2023-24 V-2 Pg No 41 IteM no 8.3.1Providing 20 MM ceMent plaster of Mix :1:4 (1 ceMent: 4 fine sand) to brick/stone Masonry including rounding off corners wherever required sMooth rendering, providing and reMoving scaffolding, including cost of Materials, labour, curing coMplete as per specifications and as per directions of Engineer-in-charge ---- etc., complete with all leadSqm467.84467.8485.0FalseNoneNoneFalseNoneFalse39766.40
299924799923NoneCSR 2023-24 V-2 Pg No 46 IteM no 8.3Finishing walls with Acrylic SMooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 M² over and including priMing coat of exterior priMer applied @ 2.20 kg/10 M²) with paint of approved quality to give an even shade, after thoroughly brooMing the surface to reMove all dirt, dust, Mortar drops and foreign Matter including preparing the surface even and sand paper sMooth, cost of Materials, labour coMplete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm229.95229.9558.38FalseNoneNoneFalseNoneFalse13424.4810
299924899923NoneCSR 2023-24 V-2 Pg No 83 IteM no 11.16.3Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priMing coat of approved steel priMer, including welding and bolted with special shaped washers etc. coMplete. Electric resistance or induction butt welded tubes including cost of Materials, labour, usage charges of Machinery coMplete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg161.23161.2322.5FalseNoneNoneFalseNoneFalse3627.6750
299924999923NoneCSR 2023-24 V-2 Pg No 85 IteM no 11.28Providing and fixing stainless steel ( Grade 304) railing Made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and Making curvature (wherever required) and fitting the saMe with necessary stainless steel nuts and bolts coMplete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangeMent as per approval of Engineer-in- charge, (for payMent purpose only weight of stainless steel MeMbers shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of Materials, labour, usage charges of Machinery coMplete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg746.7746.731.2FalseNoneNoneFalseNoneFalse23297.040
299925099923NoneCSR 2023-24 V-5 Pg No 113 IteM no 10.1.5Providing PVC ringtite pipes conforMing to IS 4985:2000 with latest aMendMents and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and coMMissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cMs. with soft gravel or selected earth available froM the excavation etc. coMplete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will Make his own arrangeMents for procuring water for testing) etc. PVC pipes 75MM dia., 6 kg/sqcM & class 3 ---- etc., complete with all leadm290.75290.75100.0FalseNoneNoneFalseNoneFalse29075.00
299925199923NoneCSR 2023-24 V-5 Pg No 113 IteM no 10.1.7Providing PVC ringtite pipes conforMing to IS 4985:2000 with latest aMendMents and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and coMMissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cMs. with soft gravel or selected earth available froM the excavation etc. coMplete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will Make his own arrangeMents for procuring water for testing) etc.PVC pipes 110MM dia., 6 kg/sqcM & class 3 ---- etc., complete with all leadm543.17543.1751.01FalseNoneNoneFalseNoneFalse27707.10170
299925299923NoneCSR 2023-24 V-2 Pg No 122 IteM no 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having therMal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with claMps at 1.00 M spacing. This includes jointing of pipes & fittings with one step CPVC solvent ceMent and the cost of cutting chases and Making good the saMe including testing of joints coMplete as per direction of Engineer in Charge. Concealed work, including cutting chases and Making good the walls etc. 25MM dia ---- etc., complete with all leadm630.4630.450.0FalseNoneNoneFalseNoneFalse31520.00
299925399923NoneCSR 2023-24 V-2 Pg No 122 IteM no 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having therMal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with claMps at 1.00 M spacing. This includes jointing of pipes & fittings with one step CPVC solvent ceMent and the cost of cutting chases and Making good the saMe including testing of joints coMplete as per direction of Engineer in Charge. Concealed work, including cutting chases and Making good the walls etc. 32MM dia ---- etc., complete with all leadm736.13736.1350.0FalseNoneNoneFalseNoneFalse36806.50
299925499923NoneCSR 2023-24 V-2 Pg No 123 IteM no 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 Marked,with cover and suitable locking arrangeMent and Making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl11.8911.892000.0FalseNoneNoneFalseNoneFalse23780.00
299925599923NoneCSR 2023-24 V-5 Pg No 191 IteM no 16.9Constructing brick Masonry chaMber of internal diMension 600x600MM and depth of 600MM (inner diMensions) with Modular bricks of CD 75 in ceMent Mortar 1:6, bed concrete 150MM thick with 1:3:6, plastering 12 MM thick with ceMent Mortar 1:4, CC 1:2:4 coping 75MM thk for fixing CI cover & fraMe etc. excluding the cost of CI fraMe and cover. ---- etc., complete with all leadNo7208.017208.0115.0FalseNoneNoneFalseNoneFalse108120.150
299925699923NoneCSR 2023-24 V-6 Page No 11kV System IteM no 32.071.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath ArMoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, ArMouring strip thickness and resistivity as per IS-3975- 25 SqmM, 3.5 Core, (12 GI Strips - 4 x 0.8 MM) ---- etc., complete with all leadKm184427.96184427.960.131FalseNoneNoneFalseNoneFalse24160.062760
17102288870001NoneNoneBuildingsUp-gradation of infrastructure facilities to CHC at Kittur in Belagavi District(Slice-2)9247653.62
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
299925799924NoneV-2 Item No 19.22.2Dismantling tile work in floors and roofs laid in cement mortar including stacking material to the appropriate disposal area as per direction of Engineer-in-charge. For thickness of tiles above 25 mm and up to 40 mm ---- etc., complete with all leadSqm87.3287.32679.7652FalseNoneNoneFalseNoneFalse59357.0972640
299925899924NoneV-2 Item No 2.4.1Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadSqm9068.069068.064.5FalseNoneNoneFalseNoneFalse40806.270
299925999924NoneV-1 Item No 2.11Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. ---- etc., complete with all leadTonne105559.26105559.260.675FalseNoneNoneFalseNoneFalse71252.50050
299926099924NoneV-2 Item No 20.93Cleaning Quadrangle chajjas including removing of dirt dust etc., using suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes, mugs, booster pumps with portable arrangement, hose pipe etc., compl ---- etc., complete with all leadSqm17.717.760.359FalseNoneNoneFalseNoneFalse1068.35430
299926199924NoneV-2 Item No 9.12.2Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm mm ---- etc., complete with all leadSqm1351.11351.1626.0FalseNoneNoneFalseNoneFalse845788.60
299926299924NoneV-2 Item No 9.23Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent ---- etc., complete with all leadSqm2909.882909.8819.5FalseNoneNoneFalseNoneFalse56742.660
299926399924NoneV-2 Item No 9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. ---- etc., complete with all leadSqm1049.021049.0291.991FalseNoneNoneFalseNoneFalse96500.398820
299926499924NoneV-2 Item No 20.47Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge ---- etc., complete with all leadEach355.18355.1825.0FalseNoneNoneFalseNoneFalse8879.50
299926599924NoneV-2 Item No 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge ---- etc., complete with all leadSqm118.0118.02663.413FalseNoneNoneFalseNoneFalse314282.7340
299926699924NoneV-2 Item No 8.57Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm15.3415.342663.413FalseNoneNoneFalseNoneFalse40856.755420
299926799924NoneV-2 Item No 8.63Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. ---- etc., complete with all leadSqm96.7696.762663.413FalseNoneNoneFalseNoneFalse257711.841880
299926899924NoneV-2 Item No 12.11Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. ---- etc., complete with all leadCum162927.32162927.320.629FalseNoneNoneFalseNoneFalse102481.284280
299926999924NoneV-2 Item No 12.57.5Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification..35 mm thick one side teak and one side commercial ---- etc., complete with all leadSqm4598.464598.4623.04FalseNoneNoneFalseNoneFalse105948.51840
299927099924NoneV-2 Item No 12.83.2Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance plus or minus1mm), with wall thickness 2.0 mm (plus or minus 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (plus or minus 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge.42x50 mm PVC Extruded section ---- etc., complete with all leadm282.02282.0212.6FalseNoneNoneFalseNoneFalse3553.4520
299927199924NoneV-2 Item No 12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with both side prelam ---- etc., complete with all leadSqm2791.882791.8812.6FalseNoneNoneFalseNoneFalse35177.6880
299927299924NoneV-2 Item No 12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications ---- etc., complete with all leadNo1198.881198.8810.0FalseNoneNoneFalseNoneFalse11988.80
299927399924NoneV-2 Item No 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg666.7666.757.8377FalseNoneNoneFalseNoneFalse38560.394590
299927499924NoneV-2 Item No 7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required ---- etc., complete with all leadSqm670.24670.2495.0FalseNoneNoneFalseNoneFalse63672.80
299927599924NoneV-2 Item No 11.16.3Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadSqm143.96143.96950.0FalseNoneNoneFalseNoneFalse136762.00
299927699924NoneV-2 Item No 8.75.1Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (Two coats applied @ 1.43 l/ 10 m²) over existing cement paint surface including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm130.98130.981451.913FalseNoneNoneFalseNoneFalse190171.564740
299927799924NoneV-2 Item No 12.69.212.69.20 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc.125mm ---- etc., complete with all leadNo286.74286.7432.0FalseNoneNoneFalseNoneFalse9175.680
299927899924NoneV-2 Item No 444Hold fasts ---- etc., complete with all leadNo59.059.032.0FalseNoneNoneFalseNoneFalse1888.00
299927999924NoneV-2 Item No 12.73.1Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete :125mm ---- etc., complete with all leadNo51.9251.9216.0FalseNoneNoneFalseNoneFalse830.720
299928099924NoneV-2 Item No 12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete ---- etc., complete with all leadNo141.6141.68.0FalseNoneNoneFalseNoneFalse1132.80
299928199924NoneV-2 Item No 12.612.60 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. ---- etc., complete with all leadNo1241.361241.368.0FalseNoneNoneFalseNoneFalse9930.880
299928299924NoneV-2 Item No 12.6312.63 Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete ---- etc., complete with all leadNo153.4153.48.0FalseNoneNoneFalseNoneFalse1227.20
299928399924NoneV-2 Item No 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid ---- etc., complete with all leadEach7052.867052.8612.0FalseNoneNoneFalseNoneFalse84634.320
299928499924NoneV-2 Item No 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required::White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests ---- etc., complete with all leadEach5763.125763.124.0FalseNoneNoneFalseNoneFalse23052.480
299928599924NoneV-2 Item No 14.7.8Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Surgeon type wash basin of size 660x460 mm with a pair of 15 mm C.P. brass pillar taps with elbow including oper- ated levers) ---- etc., complete with all leadEach4853.344853.3416.0FalseNoneNoneFalseNoneFalse77653.440
299928699924NoneV-2 Item No 14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer in-charge. ---- etc., complete with all leadEach955.8955.816.0FalseNoneNoneFalseNoneFalse15292.80
299928799924NoneV-2 Item No 14.22BProviding and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. ---- etc., complete with all leadEach6563.166563.1616.0FalseNoneNoneFalseNoneFalse105010.560
299928899924NoneV-2 Item No 14.29Providing and fixing 100 mm sand cast Iron grating for gully trap. ---- etc., complete with all leadEach55.4655.4616.0FalseNoneNoneFalseNoneFalse887.360
299928999924None18-19 SR Item No 12.113.2Providing and fixing Cl Nahani trap of approved make conforming to lSI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot).12.5mmx75mm ---- etc., complete with all leadEach241.9241.916.0FalseNoneNoneFalseNoneFalse3870.40
299929099924NoneV-2 Item No 14.36.2Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 g. ---- etc., complete with all leadEach109.74109.7416.0FalseNoneNoneFalseNoneFalse1755.840
299929199924NoneV-2 Item No 13.25Providing and fixing PTMT swivelling shower, 15 mm nominal bore,weighing not less than 40 gms ---- etc., complete with all leadNo172.28172.2816.0FalseNoneNoneFalseNoneFalse2756.480
299929299924NoneV-5 Item No 10.1.2Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete. for: PVC pipes 32mm dia., 10 kg/sqcm & class 5 ---- etc., complete with all leadm79.0679.06100.0FalseNoneNoneFalseNoneFalse7906.00
299929399924NoneV-5 Item No 10.1.3Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete. for: PVC pipes 50mm dia., 6 kg/sqcm & class 5 ---- etc., complete with all leadm119.18119.18120.0FalseNoneNoneFalseNoneFalse14301.60
299929499924NoneV-5 Item No 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete. for: PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm259.6259.680.0FalseNoneNoneFalseNoneFalse20768.00
299929599924NoneV-5 Item No 10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm484.98484.9830.0FalseNoneNoneFalseNoneFalse14549.40
299929699924NoneV-5 Item No 10.1.8Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.complete. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm689.12689.1230.0FalseNoneNoneFalseNoneFalse20673.60
299929799924NoneV-2 Item No 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia ---- etc., complete with all leadm364.62364.6260.0FalseNoneNoneFalseNoneFalse21877.20
299929899924NoneV-2 Item No 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm dia ---- etc., complete with all leadm447.22447.2260.0FalseNoneNoneFalseNoneFalse26833.20
299929999924NoneV-2 Item No 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm dia ---- etc., complete with all leadm562.86562.86140.0FalseNoneNoneFalseNoneFalse78800.40
299930099924NoneV-2 Item No 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm dia ---- etc., complete with all leadm657.26657.2660.0FalseNoneNoneFalseNoneFalse39435.60
299930199924NoneV-2 Item No 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.6210.624000.0FalseNoneNoneFalseNoneFalse42480.00
299930299924NoneV-5 Item No 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. ---- etc., complete with all leadNo6435.726435.7210.0FalseNoneNoneFalseNoneFalse64357.20
299930399924NoneV-6 Item No 1.8.1Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 20 mm ---- etc., complete with all leadm33.0433.041440.0FalseNoneNoneFalseNoneFalse47577.60
299930499924NoneV-6 Item No 1.8.2Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25 mm ---- etc., complete with all leadm41.341.31800.0FalseNoneNoneFalseNoneFalse74340.00
299930599924NoneV-6 Item No 2.2.1POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Short point upto 3 mts from tapping point to out let via switch box ---- etc., complete with all leadPoint317.42317.4224.0FalseNoneNoneFalseNoneFalse7618.080
299930699924NoneV-6 Item No 2.2.2POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Medium point above 3 mts upto 6mts from tapping point to outlet via switch box ---- etc., complete with all leadPoint447.22447.2216.0FalseNoneNoneFalseNoneFalse7155.520
299930799924NoneV-6 Item No 2.2.3POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Long point above 6 mts upto 10 mts from tapping point to outlet via switch box ---- etc., complete with all leadPoint654.9654.916.0FalseNoneNoneFalseNoneFalse10478.40
299930899924NoneV-6 Item No 2.2.4POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Two outlet in a row above 3mts upto 6 mts from tapping point to outlet via switches ---- etc., complete with all leadPoint798.86798.8610.0FalseNoneNoneFalseNoneFalse7988.60
299930999924NoneV-6 Item No 2.2.5POINT WIRING USING COPPER WIRE WITHOUT SWITCH Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for Each outlet. Three outlet in a row above 6 mts upto 10 mts from the tapping point to outlet via switches ---- etc., complete with all leadPoint1167.021167.024.0FalseNoneNoneFalseNoneFalse4668.080
299931099924NoneV-6 Item No 2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1 mm2 ---- etc., complete with all leadm22.4222.42500.0FalseNoneNoneFalseNoneFalse11210.00
299931199924NoneV-6 Item No 2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5 mm2 ---- etc., complete with all leadm30.6830.683000.0FalseNoneNoneFalseNoneFalse92040.00
299931299924NoneV-6 Item No 2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5 mm2 ---- etc., complete with all leadm49.5649.562500.0FalseNoneNoneFalseNoneFalse123900.00
299931399924NoneV-6 Item No 2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4 mm2 ---- etc., complete with all leadm74.3474.34400.0FalseNoneNoneFalseNoneFalse29736.00
299931499924NoneV-6 Item No 2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 6 mm2 ---- etc., complete with all leadm108.56108.56300.0FalseNoneNoneFalseNoneFalse32568.00
299931599924NoneV-6 Item No 3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 1-2 Way ---- etc., complete with all leadEach121.53121.5324.0FalseNoneNoneFalseNoneFalse2916.720
299931699924NoneV-6 Item No 3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3 Way ---- etc., complete with all leadEach146.32146.3224.0FalseNoneNoneFalseNoneFalse3511.680
299931799924NoneV-6 Item No 3.3.3Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 4-5 Way ---- etc., complete with all leadEach161.66161.6620.0FalseNoneNoneFalseNoneFalse3233.20
299931899924NoneV-6 Item No 3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6 Way ---- etc., complete with all leadEach204.14204.1420.0FalseNoneNoneFalseNoneFalse4082.80
299931999924NoneV-6 Item No 3.3.5Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 8 Way ---- etc., complete with all leadEach258.42258.4220.0FalseNoneNoneFalseNoneFalse5168.40
299932099924NoneV-6 Item No 3.3.6Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 10-12 Way ---- etc., complete with all leadEach307.98307.9816.0FalseNoneNoneFalseNoneFalse4927.680
299932199924NoneV-6 Item No 3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 1 to 2Module ---- etc., complete with all leadEach161.66161.6624.0FalseNoneNoneFalseNoneFalse3879.840
299932299924NoneV-6 Item No 3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 3Module ---- etc., complete with all leadEach189.98189.9824.0FalseNoneNoneFalseNoneFalse4559.520
299932399924NoneV-6 Item No 3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 4 Module ---- etc., complete with all leadEach206.5206.520.0FalseNoneNoneFalseNoneFalse4130.00
299932499924NoneV-6 Item No 3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 6 Module ---- etc., complete with all leadEach276.12276.1220.0FalseNoneNoneFalseNoneFalse5522.40
299932599924NoneV-6 Item No 3.5.5Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 8 Module ---- etc., complete with all leadEach335.12335.1220.0FalseNoneNoneFalseNoneFalse6702.40
299932699924NoneV-6 Item No 3.5.6Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws , bolts nuts etc,.complete on the existing metal/PVC box 10/12 Module ---- etc., complete with all leadEach405.92405.9210.0FalseNoneNoneFalseNoneFalse4059.20
299932799924NoneV-6 Item No 3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 amps one way switch ---- etc., complete with all leadEach120.36120.3616.0FalseNoneNoneFalseNoneFalse1925.760
299932899924NoneV-6 Item No 3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 amps two way switch ---- etc., complete with all leadEach195.88195.8816.0FalseNoneNoneFalseNoneFalse3134.080
299932999924NoneV-6 Item No 3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6 Amps 3 way sockets ---- etc., complete with all leadEach201.78201.7824.0FalseNoneNoneFalseNoneFalse4842.720
299933099924NoneV-6 Item No 3.6.4Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. stepped fan Regulator's Two module ---- etc., complete with all leadEach421.26421.2620.0FalseNoneNoneFalseNoneFalse8425.20
299933199924NoneV-6 Item No 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16 Amps universal sockets ---- etc., complete with all leadEach278.48278.4824.0FalseNoneNoneFalseNoneFalse6683.520
299933299924NoneV-6 Item No 3.6.7Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16 Amps one way Switch ---- etc., complete with all leadEach212.4212.412.0FalseNoneNoneFalseNoneFalse2548.80
299933399924NoneV-6 Item No 3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone socket ---- etc., complete with all leadEach184.07184.072.0FalseNoneNoneFalseNoneFalse368.140
299933499924NoneV-6 Item No 3.14.14 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A SP Switch ---- etc., complete with all leadEach64.964.924.0FalseNoneNoneFalseNoneFalse1557.60
299933599924NoneV-6 Item No 3.14.24 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Two Way Switch ---- etc., complete with all leadEach82.682.630.0FalseNoneNoneFalseNoneFalse2478.00
299933699924NoneV-6 Item No 3.14.34 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Three Way 5 Pin Socket ---- etc., complete with all leadEach82.682.630.0FalseNoneNoneFalseNoneFalse2478.00
299933799924NoneV-6 Item No 3.14.44 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Three Pin Top ---- etc., complete with all leadEach102.66102.6624.0FalseNoneNoneFalseNoneFalse2463.840
299933899924NoneV-6 Item No 3.14.54 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bakelite Ceiling Rose ---- etc., complete with all leadEach92.0392.0324.0FalseNoneNoneFalseNoneFalse2208.720
299933999924NoneV-6 Item No 3.14.64 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Pendant Holder ---- etc., complete with all leadEach83.7883.7824.0FalseNoneNoneFalseNoneFalse2010.720
299934099924NoneV-6 Item No 3.14.74 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Batten Holder ---- etc., complete with all leadEach87.3287.324.0FalseNoneNoneFalseNoneFalse349.280
299934199924NoneV-6 Item No 3.14.84 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bell Push ---- etc., complete with all leadEach82.682.620.0FalseNoneNoneFalseNoneFalse1652.00
299934299924NoneV-6 Item No 3.14.94 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 6A Bell Buzzer ---- etc., complete with all leadEach153.4153.424.0FalseNoneNoneFalseNoneFalse3681.60
299934399924NoneV-6 Item No 3.14.104 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A SP Switch ---- etc., complete with all leadEach154.57154.578.0FalseNoneNoneFalseNoneFalse1236.560
299934499924NoneV-6 Item No 3.14.114 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Two Way Switch ---- etc., complete with all leadEach172.28172.2824.0FalseNoneNoneFalseNoneFalse4134.720
299934599924NoneV-6 Item No 3.14.124 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Three Way 5 Pin Socket ---- etc., complete with all leadEach135.7135.76.0FalseNoneNoneFalseNoneFalse814.20
299934699924NoneV-6 Item No 3.14.134 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16A Three Pin Top ---- etc., complete with all leadEach129.8129.88.0FalseNoneNoneFalseNoneFalse1038.40
299934799924NoneV-6 Item No 3.14.144 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 32A Bakelite DP ---- etc., complete with all leadEach273.76273.768.0FalseNoneNoneFalseNoneFalse2190.080
299934899924NoneV-6 Item No 3.14.154 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board 16/6A combined plug and socket with control switch ---- etc., complete with all leadEach257.24257.246.0FalseNoneNoneFalseNoneFalse1543.440
299934999924NoneV-6 Item No 3.14.164 Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board Electronic stepped regulator. ---- etc., complete with all leadEach331.58331.587.0FalseNoneNoneFalseNoneFalse2321.060
299935099924NoneV-6 Item No 5.18.1Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP ---- etc., complete with all leadEach489.7489.78.0FalseNoneNoneFalseNoneFalse3917.60
299935199924NoneV-6 Item No 5.18.2Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A SP ---- etc., complete with all leadEach935.74935.746.0FalseNoneNoneFalseNoneFalse5614.440
299935299924NoneV-6 Item No 5.18.3Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A SP ---- etc., complete with all leadEach956.98956.984.0FalseNoneNoneFalseNoneFalse3827.920
299935399924NoneV-6 Item No 5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP ---- etc., complete with all leadEach872.02872.025.0FalseNoneNoneFalseNoneFalse4360.10
299935499924NoneV-6 Item No 5.18.5Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP ---- etc., complete with all leadEach1250.81250.83.0FalseNoneNoneFalseNoneFalse3752.40
299935599924NoneV-6 Item No 5.18.6Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A DP ---- etc., complete with all leadEach1300.361300.362.0FalseNoneNoneFalseNoneFalse2600.720
299935699924NoneV-6 Item No 5.18.7Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A TPN ---- etc., complete with all leadEach2026.062026.062.0FalseNoneNoneFalseNoneFalse4052.120
299935799924NoneV-6 Item No 5.18.8Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN ---- etc., complete with all leadEach3591.923591.922.0FalseNoneNoneFalseNoneFalse7183.840
299935899924NoneV-6 Item No 5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN ---- etc., complete with all leadEach3643.843643.842.0FalseNoneNoneFalseNoneFalse7287.680
299935999924NoneV-6 Item No 5.19.1Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 4 Way SP & N ---- etc., complete with all leadEach1464.381464.388.0FalseNoneNoneFalseNoneFalse11715.040
299936099924NoneV-6 Item No 5.19.2Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 6 Way SP & N ---- etc., complete with all leadEach1399.481399.486.0FalseNoneNoneFalseNoneFalse8396.880
299936199924NoneV-6 Item No 5.19.3Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N ---- etc., complete with all leadEach1760.561760.564.0FalseNoneNoneFalseNoneFalse7042.240
299936299924NoneV-6 Item No 5.19.4Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 12 Way SP & N ---- etc., complete with all leadEach2198.342198.345.0FalseNoneNoneFalseNoneFalse10991.70
299936399924NoneV-6 Item No 5.19.5Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.I - Single Door 16 Way SP & N ---- etc., complete with all leadEach3459.763459.763.0FalseNoneNoneFalseNoneFalse10379.280
299936499924NoneV-6 Item No 5.46.1Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A SP ---- etc., complete with all leadEach247.8247.82.0FalseNoneNoneFalseNoneFalse495.60
299936599924NoneV-6 Item No 5.46.4Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 16 - 32 A TP ---- etc., complete with all leadEach946.36946.362.0FalseNoneNoneFalseNoneFalse1892.720
299936699924NoneV-6 Item No 5.32Supplying and fixing digital frequency meter with latest micro controller technology, ultra bright 4 digit LED display, from 30-500V AC and optional or relay output for high/low frequency and wiring complete ---- etc., complete with all leadEach1150.51150.52.0FalseNoneNoneFalseNoneFalse2301.00
299936799924NoneV-6 Item No Item No. 51.01GI Grounding pipe, B - Class, 42 mm dia, 2.5 M long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg ---- etc., complete with all leadNo876.74876.743.0FalseNoneNoneFalseNoneFalse2630.220
299936899924NoneV-6 Item No Item No. 51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg Each ---- etc., complete with all leadNo797.68797.683.0FalseNoneNoneFalseNoneFalse2393.040
299936999924NoneV-6 Item No Item No. 51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bag ---- etc., complete with all leadBag365.8365.83.0FalseNoneNoneFalseNoneFalse1097.40
299937099924NoneV-6 Item No Item No. 8.0310 SWG GI Wire (3.251 mm Dia), Std Wt: 82 Kg/KM ---- etc., complete with all leadm93421.7893421.783.0FalseNoneNoneFalseNoneFalse280265.340
299937199924NoneV-6 Item No Item No. 1.6.2Digging of Pit for providing GI Pipe type Earthing Hard Soil ---- etc., complete with all leadPer Pit3528.23528.23.0FalseNoneNoneFalseNoneFalse10584.60
299937299924NoneV-6 Item No 11.3.1Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W ---- etc., complete with all leadEach650.18650.1830.0FalseNoneNoneFalseNoneFalse19505.40
299937399924NoneV-6 Item No 11.3.2Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W ---- etc., complete with all leadEach814.2814.230.0FalseNoneNoneFalseNoneFalse24426.00
299937499924NoneV-6 Item No 6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model ---- etc., complete with all leadEach3521.123521.1210.0FalseNoneNoneFalseNoneFalse35211.20
299937599924NoneV-6 Item No 13.13Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. ---- etc., complete with all leadEach834.26834.264.0FalseNoneNoneFalseNoneFalse3337.040
299937699924NoneV-6 Item No 13.19Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. ---- etc., complete with all leadEach578.2578.260.0FalseNoneNoneFalseNoneFalse34692.00
299937799924NoneV-6 Item No58.0111 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) ---- etc., complete with all leadNo287296.96287296.961.0FalseNoneNoneFalseNoneFalse287296.960
299937899924NoneV-3 ITEM NO 2.4 (A)Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness..By Manual MeansIn area of light jungle ---- etc., complete with all leadSqm1323.961323.960.48FalseNoneNoneFalseNoneFalse635.50080
299937999924NoneV-1 ITEM NO 1.12Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth ---- etc., complete with all leadCum112.1112.114.399FalseNoneNoneFalseNoneFalse1614.12790
299938099924NoneV-1 ITEM NO 1.15Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work ---- etc., complete with all leadCum546.34546.34100.8FalseNoneNoneFalseNoneFalse55071.0720
299938199924NoneV-1 ITEM NO 2.1.2Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum6683.526683.524.914FalseNoneNoneFalseNoneFalse32842.817280
299938299924NoneV-1 ITEM NO 2.5.2Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ---- etc., complete with all leadCum12112.1112112.1127.18FalseNoneNoneFalseNoneFalse329207.14980
299938399924NoneV-1 ITEM NO 2.11 (a)Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. for Building ---- etc., complete with all leadTonne105559.26105559.263.4FalseNoneNoneFalseNoneFalse358901.4840
299938499924NoneV-2 ITEM NO 15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. ---- etc., complete with all leadSqm964.06964.0678.6FalseNoneNoneFalseNoneFalse75775.1160
299938599924NoneV-2 ITEM NO 8.12Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin-Charge. ---- etc., complete with all leadKg75.5275.5235.0FalseNoneNoneFalseNoneFalse2643.20
299938699924NoneV-2 ITEM NO 6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications ---- etc., complete with all leadSqm1545.81545.80.899FalseNoneNoneFalseNoneFalse1389.67420
299938799924NoneV-2 ITEM NO 8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm437.78437.7856.94FalseNoneNoneFalseNoneFalse24927.19320
299938899924NoneV-2 ITEM NO 8.3.1Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per diretions of Engineer-in-charge ---- etc., complete with all leadSqm417.72417.7262.6FalseNoneNoneFalseNoneFalse26149.2720
299938999924NoneV-2 ITEM NO 8.3Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ---- etc., complete with all leadSqm205.32205.3256.94FalseNoneNoneFalseNoneFalse11690.92080
299939099924NoneITEM NO XXXVIIIC. I Manhole covers 24" x 24" ---- etc., complete with all leadNo2952.362952.362.0FalseNoneNoneFalseNoneFalse5904.720
299939199924NoneV-2 ITEM NO 11.16.3Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg143.96143.9622.5FalseNoneNoneFalseNoneFalse3239.10
299939299924NoneV-2 ITEM NO 11.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. ---- etc., complete with all leadKg666.7666.724.0FalseNoneNoneFalseNoneFalse16000.80
299939399924NoneV-5 ITEM NO 10.1.5Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 75mm dia., 6 kg/sqcm & class 3 ---- etc., complete with all leadm259.6259.6150.0FalseNoneNoneFalseNoneFalse38940.00
299939499924NoneV-2 ITEM NO 13.32.1Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15mm dia ---- etc., complete with all leadm364.62364.6285.0FalseNoneNoneFalseNoneFalse30992.70
299939599924NoneV-2 ITEM NO 13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20mm dia ---- etc., complete with all leadm447.22447.2265.0FalseNoneNoneFalseNoneFalse29069.30
299939699924NoneV-2 ITEM NO 13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25mm dia ---- etc., complete with all leadm562.86562.86100.0FalseNoneNoneFalseNoneFalse56286.00
299939799924NoneV-2 ITEM NO 13.32.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 32mm dia ---- etc., complete with all leadm657.26657.26200.0FalseNoneNoneFalseNoneFalse131452.00
299939899924NoneV-2 ITEM NO 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. ---- etc., complete with all leadl10.6210.624000.0FalseNoneNoneFalseNoneFalse42480.00
299939999924NoneV-5 ITEM NO 16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. ---- etc., complete with all leadNo6435.726435.7215.0FalseNoneNoneFalseNoneFalse96535.80
299940099924None144BAR SCREEN CHAMBER: MSFRP Bar Screen chamber rectangular tank,made up of Mild steel coated with FRP lining,Bar Screen Chamber Diemesion:1000x1000x1000 Length :1000 mm,Width :1000 mm,Height :1000 mm,Mild steel sheet Thickness: 3mm,FRP Lining ,Internal Thickness : 2mm,External Thcness: 2mm,inlet nozzelDia :4 inch,outLetnozzel Dia: 4 Bar Screen Size : 10mm,screen MOC : Mild Steel,Screen coating : Epoxy,Make : Orionwater. ---- etc., complete with all leadSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
299940199924None145RAW SEWAGE TRANSFER PUMP Raw Sewage transfer pump capable of handling,sewage transfer from collection tank to RBC STP,maximum solid handling size upto 50 mm,Type : Centrifugal monoblock,Impeller :open,motor HP:1,RPM:2700,Flow Rate:1 m3/hr,Head:10,Moc : Cl,solid Particle Size Handling: 7 mm A).Valve : Suction : 2 nos,Delivery : 2 nos,Size :50 mm,Moc : B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set. ---- etc., complete with all leadSet59000.059000.01.0FalseNoneNoneFalseNoneFalse59000.00
299940299924None146STP Rectamgular Tank Size and dimension:Width : 1500 mm, Over Height including Top Cover : 3000 mm, Length :5350 mm, MOC of rectangular Tank : Mild Steel, Shell Thickness: 5 mm FRP lining, Internal Liniing : 3 mm, External Lining : 3 mm, Pipe inlet Dia: 80 mm, Pipe Outlet Dia: 80 mm, Drain Header pipe Dia: 80 mm ---- etc., complete with all leadSet888540.0888540.01.0FalseNoneNoneFalseNoneFalse888540.00
299940399924None147Primary clarifier : Type : Lamella, No of Plates: 10, Lamella plate MOC: FRP, Lemella Plate Thickness: 2 mm ---- etc., complete with all leadSet398840.0398840.01.0FalseNoneNoneFalseNoneFalse398840.00
299940499924None148Secondary clarifier: Type : Lamella, No of Plates: 19, Lamella plate MOC: FRP, Lemella Plate Thickness: 3 mm ---- etc., complete with all leadSet391760.0391760.01.0FalseNoneNoneFalseNoneFalse391760.00
299940599924None149ROTOR: No of Rotors: 2, Moc: FRP, Diameter of Rotor : 1000mm, Connected with , Shaft : EN 90 Rod, Driven by : pillar Block, No of pillar block: 4 ---- etc., complete with all leadSet252520.0252520.01.0FalseNoneNoneFalseNoneFalse252520.00
299940699924None150Bio Zone (Rotor Placement Boat) No. of Biozone : 1 No, No. of Partisian inside Bio-zone : 4 Nos, MOC : MSFRP, Boat curvature Diameter : 1800mm, Bio Zone supporting with 150mm, Beam 2 Nos & 4 Nos. Legs., Boat Size:3350 mm ---- etc., complete with all leadSet318600.0318600.01.0FalseNoneNoneFalseNoneFalse318600.00
299940799924None151Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (Germany), Gear Box Motor HP: 1, Gear Box motor Make : Seimens. ---- etc., complete with all leadSet112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
299940899924None152Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain system. 2)Base Plate works for Gear box arrangement,Rotor Fixing arrangement,Biozone leg placement arrangement. RBC STP Make : Orionwater ---- etc., complete with all leadSet68440.068440.01.0FalseNoneNoneFalseNoneFalse68440.00
299940999924None153FILTER FEED PUMP: Filter feed pump capable of handling to transfer clarifed to filtration plant maximum solid handling size upto 20 mm, Type : Centrifugal monoblock, Impeller : Closed motor HP:3, RPM:1700, Flow Rate: 6m3/hr, Head:30, Moc : solid Particle Size Handling: 50mm Valve , Suction : 2 nos, Delivery : 2 nos, Size :50 mm, Moc : Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : , Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set ---- etc., complete with all leadSet29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
299941099924None154SAND FILTER : Diameter: 600 mm, Height On Straight: 1900 mm, Shell hickness: 6mm, Dish end Thickness: 8mm, Frontal Pipeline:, MOC: Mild Steel, External Coating : Red Oxide and Enamel paint, Internal Coating: Black Bitumus, Fiter Media: Fine Sand, Gravel sand, pebbles,silex, Media in KG: 450, Media Depth : 915 mm, Type : Cylindrical, Vertical. ---- etc., complete with all leadSet123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
299941199924None155ACTIVATED CARBON FILTER: Diameter: 600 mm,Height On Straight: 1900 mm, Shell hickness: 6mm,Dish end Thickness: 8mm Frontal Pipeline: MOC: Mild Steel,External Coating :Red Oxide and Enamel paint,Internal Coating: Black Bitumus,Fiter Media: Activated Carbon Media in KG: 150,Media Depth : 1000 mm,Type : Cylindrical. ---- etc., complete with all leadSet123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
299941299924None156CHLORINE DOSING SYSTEM, Pump type : ElectonicDiaphram Capacity : 0- 2LPH, Nominal Back pressure : 6 KG/CM2, Maximum Back pressure: 8 KG/CM2 KW: 0.24 watt, Tank Capacity : 100 Liters, MOC: PP, Make : LMI Asia ---- etc., complete with all leadSet33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
299941399924None157INTERCONNECTING PIPE WORK All necessary pipe work from Bar Screen chamber to collection tank, collection tank to Raw sewage transfer pump, Raw sewage transfer pump to RBC STP, RBC STP to Filter feed pump, Filter feed pump to Filtration plant and filtration plant to treated water tank The scope shall be PVC pipes with all necessary valves, NRV , Float switch and drain Header. ---- etc., complete with all leadSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
299941499924None158CONTROL PANEL: Installation, testing and commissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting type, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi-tier arrangement. The painting shall be done in conformity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. ---- etc., complete with all leadSet147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
299941599924None159FREIGHT LOADING AND UNLOADING : All the equipment shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the system ---- etc., complete with all leadSet70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
299941699924None160INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. From the Inlet of the Bar Screen chamber to the output of Caron filter ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
299941799924NoneV-6 Item No 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 35 Sqmm ---- etc., complete with all leadKm181793.16181793.160.15FalseNoneNoneFalseNoneFalse27268.9740
299941899924NoneSR 21-22 V-6 Item No BSR-31.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 Sqmm to 95 Sqmm ---- etc., complete with all leadKm36744.0236744.020.15FalseNoneNoneFalseNoneFalse5511.6030
299941999924None19-20 SR Item No 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 32mm dia ---- etc., complete with all leadEach138.06138.068.0FalseNoneNoneFalseNoneFalse1104.480
299942099924NoneSR 21-22 V-6 Item No BSR 49.05Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. 50mm ---- etc., complete with all leadm451.94451.9410.0FalseNoneNoneFalseNoneFalse4519.40
299942199924None19-20 SR Item No 6.17.8Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 35 Sqmm Long Barrel ---- etc., complete with all leadEach37.7637.764.0FalseNoneNoneFalseNoneFalse151.040
299942299924NoneSR 21-22 V-6 Item No BSR-29.03Earth work excavation for cable trench of 0.5 to 0.75 M. Width and Depth upto 1 M including trial pits, depositing on bank upto a lead of 50 M,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 M wherever necessary as directed. In soil (hard) ---- etc., complete with all leadCum459.02459.0230.0FalseNoneNoneFalseNoneFalse13770.60
299942399924NoneV-6 Item No 12.57Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 M long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. ---- etc., complete with all leadNo5022.085022.082.0FalseNoneNoneFalseNoneFalse10044.160
299942499924None19-20 SR Item No 6.18.3Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.,(75/23) 8 SWG-GI Wire ---- etc., complete with all leadm22.4222.4250.0FalseNoneNoneFalseNoneFalse1121.00
299942599924NoneV-6 Item No 12.58Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip ---- etc., complete with all leadm96.7696.7625.0FalseNoneNoneFalseNoneFalse2419.00
17102288870000NoneNoneBuildingsConstruction of STP at CHC Harugeri in Raibag taluk, Belagavi District(Slice-3)2999863.93
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
299942699925None001BAR SCREEN CHAMBER: MSFRP Bar Screen chamber rectangular tank,made up of Mild steel coated with FRP lining,Bar Screen Chamber Diemesion:1000x1000x1000 Length :1000 mm,Width :1000 mm,Height :1000 mm,Mild steel sheet Thickness: 3mm,FRP Lining ,Internal Thickness : 2mm,External Thcness: 2mm,inlet nozzelDia :4 inch,outLetnozzel Dia: 4 Bar Screen Size : 10mm,screen MOC : Mild Steel,Screen coating : Epoxy,Make : Orionwater. ---- etc., complete with all leadSet53100.053100.01.0FalseNoneNoneFalseNoneFalse53100.00
299942799925None002RAW SEWAGE TRANSFER PUMP Raw Sewage transfer pump capable of handling,sewage transfer from collection tank to RBC STP,maximum solid handling size upto 50 mm,Type : Centrifugal monoblock,Impeller :open,motor HP:1,RPM:2700,Flow Rate:1 m3/hr,Head:10,Moc : Cl,solid Particle Size Handling: 7 mm A).Valve : Suction : 2 nos,Delivery : 2 nos,Size :50 mm,Moc : B).Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set. ---- etc., complete with all leadSet59000.059000.01.0FalseNoneNoneFalseNoneFalse59000.00
299942899925None003STP Rectamgular Tank Size and dimension:Width : 1500 mm, Over Height including Top Cover : 3000 mm, Length :5350 mm, MOC of rectangular Tank : Mild Steel, Shell Thickness: 5 mm FRP lining, Internal Liniing : 3 mm, External Lining : 3 mm, Pipe inlet Dia: 80 mm, Pipe Outlet Dia: 80 mm, Drain Header pipe Dia: 80 mm ---- etc., complete with all leadSet888540.0888540.01.0FalseNoneNoneFalseNoneFalse888540.00
299942999925None004Primary clarifier : Type : Lamella, No of Plates: 10, Lamella plate MOC: FRP, Lemella Plate Thickness: 2 mm ---- etc., complete with all leadSet398840.0398840.01.0FalseNoneNoneFalseNoneFalse398840.00
299943099925None005Secondary clarifier: Type : Lamella, No of Plates: 19, Lamella plate MOC: FRP, Lemella Plate Thickness: 3 mm ---- etc., complete with all leadSet391760.0391760.01.0FalseNoneNoneFalseNoneFalse391760.00
299943199925None006ROTOR: No of Rotors: 2, Moc: FRP, Diameter of Rotor : 1000mm, Connected with , Shaft : EN 90 Rod, Driven by : pillar Block, No of pillar block: 4 ---- etc., complete with all leadSet252520.0252520.01.0FalseNoneNoneFalseNoneFalse252520.00
299943299925None007Gear Box : Type: Helical, No of Gear Box: 1 no, Make : Bonfigoli (Germany), Gear Box Motor HP: 1, Gear Box motor Make : Seimens. ---- etc., complete with all leadSet112100.0112100.01.0FalseNoneNoneFalseNoneFalse112100.00
299943399925None008Internal Piping & Base Works : 1) Inter connecting pipe works with FRP lining inside process tank, Recirculion& drain system. 2)Base Plate works for Gear box arrangement,Rotor Fixing arrangement,Biozone leg placement arrangement. RBC STP Make : Orionwater ---- etc., complete with all leadSet68440.068440.01.0FalseNoneNoneFalseNoneFalse68440.00
299943499925None009FILTER FEED PUMP: Filter feed pump capable of handling to transfer clarifed to filtration plant maximum solid handling size upto 20 mm, Type : Centrifugal monoblock, Impeller : Closed motor HP:3, RPM:1700, Flow Rate: 6m3/hr, Head:30, Moc : solid Particle Size Handling: 50mm Valve , Suction : 2 nos, Delivery : 2 nos, Size :50 mm, Moc : Type : Ball /Butterfly, Non Return Valve, Delivery : 2 nos, Size :50 mm, Moc : , Make : Kriloskar / CRI, Pump (1 w + 1S) 2nos of pump = 1 set ---- etc., complete with all leadSet29500.029500.01.0FalseNoneNoneFalseNoneFalse29500.00
299943599925None010SAND FILTER : Diameter: 600 mm, Height On Straight: 1900 mm, Shell hickness: 6mm, Dish end Thickness: 8mm, Frontal Pipeline:, MOC: Mild Steel, External Coating : Red Oxide and Enamel paint, Internal Coating: Black Bitumus, Fiter Media: Fine Sand, Gravel sand, pebbles,silex, Media in KG: 450, Media Depth : 915 mm, Type : Cylindrical, Vertical. ---- etc., complete with all leadSet123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
299943699925None011ACTIVATED CARBON FILTER: Diameter: 600 mm,Height On Straight: 1900 mm, Shell hickness: 6mm,Dish end Thickness: 8mm Frontal Pipeline: MOC: Mild Steel,External Coating :Red Oxide and Enamel paint,Internal Coating: Black Bitumus,Fiter Media: Activated Carbon Media in KG: 150,Media Depth : 1000 mm,Type : Cylindrical. ---- etc., complete with all leadSet123900.0123900.01.0FalseNoneNoneFalseNoneFalse123900.00
299943799925None012CHLORINE DOSING SYSTEM, Pump type : ElectonicDiaphram Capacity : 0- 2LPH, Nominal Back pressure : 6 KG/CM2, Maximum Back pressure: 8 KG/CM2 KW: 0.24 watt, Tank Capacity : 100 Liters, MOC: PP, Make : LMI Asia ---- etc., complete with all leadSet33040.033040.01.0FalseNoneNoneFalseNoneFalse33040.00
299943899925None013INTERCONNECTING PIPE WORK All necessary pipe work from Bar Screen chamber to collection tank, collection tank to Raw sewage transfer pump, Raw sewage transfer pump to RBC STP, RBC STP to Filter feed pump, Filter feed pump to Filtration plant and filtration plant to treated water tank The scope shall be PVC pipes with all necessary valves, NRV , Float switch and drain Header. ---- etc., complete with all leadSet118000.0118000.01.0FalseNoneNoneFalseNoneFalse118000.00
299943999925None014CONTROL PANEL: Installation, testing and commissioning of Electrical Panel suitable for 415V, 3 phase, 4 wire, 50Hz distribution system. The panel shall be Wall Mounting type, sheet metal enclosed, flush front with aluminium busbars, separate earth bus shall be provided throughout the length of the panel. The incoming and the outgoing feeder breakers, switch fuse units, change over switches, indicating lamps, meters etc. shall be accommodated in a modular multi-tier arrangement. The painting shall be done in conformity with IS code. Adequate size cable alley shall be provided all around the panel and at the back for easy bending and terminations. The outgoing feeders inside the panel shall be connected through solid busbars. Busbars shall be provided with PVC heat shrinkable sleeves or heat resistant insulated paint. The panels shall be suitable for cable entry from top / bottom. ---- etc., complete with all leadSet147500.0147500.01.0FalseNoneNoneFalseNoneFalse147500.00
299944099925None015FREIGHT LOADING AND UNLOADING : All the equipment shall be loaded ,transported and unloaded at site. Including the necessary Cranes required to erect and position the system ---- etc., complete with all leadSet70800.070800.01.0FalseNoneNoneFalseNoneFalse70800.00
299944199925None016INSTALLATION, ERECTION, COMMISSIONING, TESTING AND HANDING OVER AT SITE. From the Inlet of the Bar Screen chamber to the output of Caron filter ---- etc., complete with all leadSet88500.088500.01.0FalseNoneNoneFalseNoneFalse88500.00
299944299925NoneCSR 2023-24 Escoms SR V-6 Pg no 13 Item no 32.091.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975. 3.5 core 35 sqmm (14 GI Strips - 4 x 0.8 mm) ---- etc., complete with all leadKm190882.82190882.820.145FalseNoneNoneFalseNoneFalse27678.00890
299944399925NoneCSR 2023-24 SR 19-20 Item no 6.11.3Supplying and fiixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only). 32mm dia ---- etc., complete with all leadEach144.96144.966.0FalseNoneNoneFalseNoneFalse869.760
299944499925NoneCSR 2023-24 Escoms SR V-6 Pg no 27 Item no 60.01Aluminium End Terminal (Lug) 10 sqmm ---- etc., complete with all leadEach2.482.486.0FalseNoneNoneFalseNoneFalse14.880
299944599925NoneCSR 2023-24 V-6 Pg no BSR Item no 29.03Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting, Using sightRails and Sign Boards at every 100 Mtr wherever necessary as directed. In soil (hard) ---- etc., complete with all leadCum481.97481.9724.61FalseNoneNoneFalseNoneFalse11861.28170
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17102288870000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17102288870000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17102288870000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of Karnataka public Procurement on or before the last date and time of bid submission.None
17102288870000NoneNoneELIGIBILITYThe bidder is required to ensure browser compatibility of the computer well in advance to the last date and time for receipt of tenders. The departments shall not be responsible for non-accessibility of Karnataka public Procurement portal due to internet connectivity issues and technical glitches at bidders endNone
17102288870000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejectionNone
17102288870000NoneNoneELIGIBILITYBidder shall pay Contract Management Module processing fees of 0.025% of the contact value (Min Rs.500/- & Max Rs.7500/-) soon after contract has been issued to bidderNone
17102288870000NoneNoneELIGIBILITYThe tenderer shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costsNone
17102288870000NoneNoneELIGIBILITYConditional tenders will not be accepted.None
17102288870000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner.None
17102288870000NoneNoneELIGIBILITYRoyalty on construction materials and other taxes will be deducted as per prevailing Govt., orders as may be modified from time to time.None
17102288870000NoneNoneELIGIBILITYAny discrepancies observed in the documents uploaded by the tenderer the tender shall liable to rejected.None
17102288870000NoneNoneELIGIBILITYEarnest Money Deposit will have to be in any one of the forms as per the instructions in the financial bid document and shall have to be valid for 45 days beyond the validity of the tender.None
17102288870000NoneNoneELIGIBILITYAll formats prescribed in the bid documents shall be filled in complete manner (section 2 & of the bid document)and shall be uploaded properly, signed by tenderer. Necessary certificates shall be uploaded along with the formats wherever required. General documents section can be used for this purposeNone
17102288870000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bidNone
17102288870000NoneNoneELIGIBILITYIf the tenderer quotes bid price below the estimated contract value (Amount put to tender) then the tenderer has to submit the additional security deposit equal to the difference in cost and the additional security deposit should have a validity for the period of execution.None
17102288870000NoneNoneELIGIBILITYIf the numbers of page to be attached in one particular attachment is more, then all the pages can be put into one folder, zipped and then attached or else all the pages can be pasted in one word file and then this word file could be converted to PDF (portable documents format) format and then attached. (Please contract help desk from 9.00 AM to 9.00 PM ( Monday to Saturday) Ph No: 91-8046010000 and 91-8068948777 or send query through Karnataka public procurement portal through query option on or before specified time.None
17102288870000NoneNoneELIGIBILITYThe Contractor shall strictly take all reasonable steps to protect the environment on and off the site and to avoid damage or nuisance to persons or to property of the public or others resulting from pollution, noise or other causes arising as a consequence of his methods of operation.None
17102288870000NoneNoneELIGIBILITYMaterials like, steel (primary), cement, bitumen etc., required for the work shall be procured by the tenderer themselves and should be got tested positive by the quality control authority before use on the work.None
17102288870000NoneNoneELIGIBILITYTenderer should have latest GST Registration and latest clearance certificate in their nameNone
17102288870000NoneNoneELIGIBILITYThe Rates quoted by the tenderer shall be inclusive of GST.None
17102288870000NoneNoneELIGIBILITYSpecial Instructions to tenderers - as per bid document.None
17102288870000NoneNoneELIGIBILITYThe Defects Liability Period is 1 year from the date of completion of the work.None
17102288870000NoneNoneELIGIBILITYTotal value of Civil Engineering Construction works executed in the and payments received in the last five year i.e., 2018-19, 2019-20, 2020-21 2021-22 & 2023-24.None
17102288870000NoneNoneELIGIBILITYThe Tenderers are bound to furnish the original certified documents to the employer within 3 days from the day of opening of technical bid for verification, failing which the bid of tenderer will be considered as technically non responsive.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneClause ITT 3.2(b)To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23) The tenderer should have been Satisfactorily completed at least one Satisfactorily completed at least one Similar work of value not less than Rs.128.50 Lakhs as prime contractor. Note : The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (b).Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(c) To qualify for award of this contract, each Tenderer in his/its name should have in the last five years i.e.(2018-19 to 2022-23).Executed in any one year, the following minimum quantities of work Sl. No Description of key items of works Quantity 1)Earthwork Excavation 215.00 Cum,2)RCC and PCC 70.00 Cum 3)Steel Reinforcement for RCC work 7.00 Tonnes 4) Cement Concrete Block Masonry/Solid Block Masonry /Load Bearing Wall/Aerated block 25.00 sqm 5)Flooring/Dadooing(Vitrified/Granite/ Ceramic/Cement concrete/cladding/ dadooing) 600.00 Sqm,6)Plastering 300.00 Sqm,7)Painting 3500.00 Sqm, 8)WPC-150.00sqm. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2(c)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(d) The tenderer or his identified sub contractor should possess required valid electrical license for executing building electrification works issued by KPWD/ Government electrical Inspectorate and should have executed similar Building electrical works totaling Rs.10.00 Lakhs in any one financial year.Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (d).The letter of willingness of the sub contractor to be engaged for electrical, should be obtained and uploaded in the KPP-portal.financialPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(e)The Tenderer or his identified sub-contractor should possess valid license for executing water supply/sanitary engineering works issued by BWSSB/ KUWS&DB and should have executed similar building water supply/sanitary engineering works totaling Rs.10.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (e).The letter of willingness of the sub contractor to be engaged for water supply & Sanitary, should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(f) The Tenderer or his identified sub-contractor should have executed similar MGPLS works totaling to Rs.20.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (f). The letter of willingness of the sub contractor to be engaged for MGPLS works should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneClause 3.2(g) The Tenderer or his identified sub-contractor should have executed similar STPworks totaling to Rs.52.00 Lakhs in any one financial year. Note-The Work done certificate should be issued by the Officer not less than the rank of Executive Engineer of State or Central Government/ Semi Government/Government undertaking/ autonomous bodies of Government will be considered for the clause 3.2 (g). The letter of willingness of the sub contractor to be engaged for STP works should be obtained and uploaded in the KPP-portal.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneList of existing commitments and ongoing worksClause 3.6 Tenderers who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The available tender capacity will be calculated for prime contractor are as under Assessed available tender capacity AxNx1.5- B Where A maximum value of civil engineering works executed in any one year during the last five years 2018-19 to 2022-23 updated to 2023-24 price level taking into account the completed as well as works in progress. N Number of years prescribed for completion of the works for which tenders are invited. B Value, at 2023 24 price level, of existing commitments and ongoing works to be completed during the next 06 months. Note:The statements showing the value of existing commitments and on-going works as well as the stipulated period of completion remaining for each of the works listed should be countersigned by the Employer in charge, not below the rank of an Executive Engineer or equivalent. certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the worksCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- certificate issued by the officer not lessthan the rank of Executive Engineer Ongoing commitments and Bids submitted for the works
NoneNoneNoneNoneKPWD Class-II and above Registration Certificate.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Class-II and above Registration Certificate.
NoneNoneNoneNoneList of Minimum Key Personnel to be deployed by the contractor at site for Contract work Sl No Position Qualification and Requirement No Of Persons 1)Site Engineer BE Civil with minimum experience of 7 years in the Construction of buildings Or Diploma in Civil Engineering with minimum experience of 10 years in the Construction of buildings and should have been working in permanent role of the organization for at least two years 2 Two Nos 2)Electrical Engineer BE Electrical with minimum experience of 5 years in the Construction of buildings Or Diploma in Electrical Engineering with minimum experience of 10 years in the Construction of buildings- 1No and should have been working inpermanent role of the organization for at least two years.Educational and Experience certificates should be uploadedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Educational and Experience certificates should be uploaded
NoneNoneNoneNoneClause ITT 3.3 (a)Equipment capacity Each tenderer should further demonstrate(a) available by owning at least 50% of the required/specified key and critical equipment for this work and (b) the remaining 50% can be deployed on ease/hire basis for all works provided, the relevant documents (commitment agreements etc.,) for availability for this work are furnished. Sl.No. Description of Equipment Quantity 1) Min 10 cft capacity Concrete Mixer-2 No. 2) Steel Centering Sheets -500sqm 3)Tipper-1 Nos 3)Excavator-1 No.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Invoice and Receipt should be uploaded.
NoneNoneNoneNoneClause ITT 3.2(a): To qualify for award of this contract, each Tenderer in his / its name should have in the last five years i.e.(2018-19 to 2022-23).The tenderer should have been achieved in at least two financial years i.e(2018-19 to 2022-23) a minimum annual financial turnover (in all classes of civil Engineering construction works only) of Rs.514.00 Lakhs. Note : a) For Clause 3.2 (a) the certificate Turn over and balance sheet duly certified by the charted accountant is to be submitted.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneClause 3.3(b)Liquid assets and /or availability of credit facilities of not less than Rs.78.00 Lakhs (Credit lines / letter of credit/ certificates from banks for meeting the fund requirement etc.(As per the prescribed format in clause 1.10 of SECTION 3, QUALIFICATION INFORMATION of this document.) as prime Contractor.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate and balance sheet issued by Charted accountant.TrueTechnical Bid
KPWD Class-II and above Registration Certificate issued by Competent authorityTrueTechnical Bid
The Work done certificate should be issued by the Officer not less than the rank of Executive EngineerTrueTechnical Bid
Tenderer should have latest GST Registration PAN Card and latest 3 GSTclearance certificate in their name.TrueTechnical Bid
Tenderer should have ESI & PF Certificates his/firm name and PF paid receipt of last month.TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710237911000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Chief Engineer, Engineering Wing, Arogya Soudha, 3rd floor, Leprosy Hospital premises, 1st cross, Magadi Road,
streetNone
citybengaluru
stateKarnataka
pin560023
tenderRecallDTONone