3002999 | 100187 | None | Code 001 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 285.56 | 285.56 | 40.21 | False | None | None | False | None | False | 11482.3676 | 0 |
3003000 | 100187 | None | Code 002 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 313.88 | 313.88 | 28.15 | False | None | None | False | None | False | 8835.722 | 0 |
3003001 | 100187 | None | Code 003 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6683.52 | 6683.52 | 14.75 | False | None | None | False | None | False | 98581.92 | 0 |
3003002 | 100187 | None | Code 004 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6620.98 | 6620.98 | 3.31 | False | None | None | False | None | False | 21915.4438 | 0 |
3003003 | 100187 | None | Code 005 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7321.9 | 7321.9 | 5.55 | False | None | None | False | None | False | 40636.545 | 0 |
3003004 | 100187 | None | Code 006 | Appendix I Additionalities for Formwork, Centering - 1. Foundation upto plinth a) Isolated - 8% | Cum | 782.34 | 782.34 | 15.01 | False | None | None | False | None | False | 11742.9234 | 0 |
3003005 | 100187 | None | Code 007 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 7418.66 | 7418.66 | 15.01 | False | None | None | False | None | False | 111354.0866 | 0 |
3003006 | 100187 | None | Code 008 | Appendix I Additionalities for Formwork, Centering - 8. Columns & Piers - 10% | Cum | 5652.31 | 5652.31 | 4.17 | False | None | None | False | None | False | 23570.1327 | 0 |
3003007 | 100187 | None | Code 009 | Appendix I Additionalities for Formwork, Centering - 12. Beams & Lintels of Building - 20% 13. Roof (Straight & arched) - 20% | Cum | 4844.84 | 4844.84 | 14.99 | False | None | None | False | None | False | 72624.1516 | 0 |
3003008 | 100187 | None | Code 010 | Supplying, Fitting and Placing un-coated TMT Fe 500 & above bar Reinforcement in Foundation complete as per Drawing and Technical Specifications. | MT | 105559.26 | 105559.26 | 2.9857 | False | None | None | False | None | False | 315168.282582 | 0 |
3003009 | 100187 | None | Code 011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7823.4 | 7823.4 | 20.65 | False | None | None | False | None | False | 161553.21 | 0 |
3003010 | 100187 | None | Code 012 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9699.6 | 9699.6 | 20.17 | False | None | None | False | None | False | 195640.932 | 0 |
3003011 | 100187 | None | Code 013 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 300.9 | 300.9 | 150.81 | False | None | None | False | None | False | 45378.729 | 0 |
3003012 | 100187 | None | Code 014 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 417.72 | 417.72 | 162.99 | False | None | None | False | None | False | 68084.1828 | 0 |
3003013 | 100187 | None | Code 015 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 205.32 | 205.32 | 162.99 | False | None | None | False | None | False | 33465.1068 | 0 |
3003014 | 100187 | None | Code 016 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 118.0 | 118.0 | 150.81 | False | None | None | False | None | False | 17795.58 | 0 |
3003015 | 100187 | None | Code 017 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 149.86 | 149.86 | 150.81 | False | None | None | False | None | False | 22600.3866 | 0 |
3003016 | 100187 | None | Code 018 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 5284.04 | 5284.04 | 2.52 | False | None | None | False | None | False | 13315.7808 | 0 |
3003017 | 100187 | None | Code 019 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). | Kg | 174.64 | 174.64 | 120.96 | False | None | None | False | None | False | 21124.4544 | 0 |
3003018 | 100187 | None | Code 020 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 198.24 | 198.24 | 120.96 | False | None | None | False | None | False | 23979.1104 | 0 |
3003019 | 100187 | None | Code 021 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.02 | 164.02 | 36.63 | False | None | None | False | None | False | 6008.0526 | 0 |
3003020 | 100187 | None | Code 022 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. | Kg | 162.84 | 162.84 | 105.0 | False | None | None | False | None | False | 17098.2 | 0 |
3003021 | 100187 | None | Code 023 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal exxpansion (i) Single socketed pipe 100 mm diameter | Mtr | 343.38 | 343.38 | 9.0 | False | None | None | False | None | False | 3090.42 | 0 |
3003022 | 100187 | None | Code 024 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., complete. | Sqm | 921.57 | 921.57 | 3.0 | False | None | None | False | None | False | 2764.71 | 0 |
3003023 | 100187 | None | Code 025 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | Mtr | 77.88 | 77.88 | 30.0 | False | None | None | False | None | False | 2336.4 | 0 |
3003024 | 100187 | None | Code 026 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20 mm dia 2 mm thick | Mtr | 80.24 | 80.24 | 20.0 | False | None | None | False | None | False | 1604.8 | 0 |
3003025 | 100187 | None | Code 027 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.3) 135 x 75 x 65 mm | Each | 253.7 | 253.7 | 2.0 | False | None | None | False | None | False | 507.4 | 0 |
3003026 | 100187 | None | Code 028 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 7) 200 x 200 x 65 mm | Each | 410.64 | 410.64 | 1.0 | False | None | None | False | None | False | 410.64 | 0 |
3003027 | 100187 | None | Code 029 | Supplying and fixing PVC/metal conduit Deep junction box - 32 mm deep Junction box | Each | 71.98 | 71.98 | 3.0 | False | None | None | False | None | False | 215.94 | 0 |
3003028 | 100187 | None | Code 030 | Supplying And Fixing Metal Fan Box with Round Hook. | Nos | 138.06 | 138.06 | 1.0 | False | None | None | False | None | False | 138.06 | 0 |
3003029 | 100187 | None | Code 031 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 447.22 | 447.22 | 4.0 | False | None | None | False | None | False | 1788.88 | 0 |
3003030 | 100187 | None | Code 032 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 1.5 mm2 | Mtr | 30.68 | 30.68 | 20.0 | False | None | None | False | None | False | 613.6 | 0 |
3003031 | 100187 | None | Code 033 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 mm2 | Mtr | 202.96 | 202.96 | 10.0 | False | None | None | False | None | False | 2029.6 | 0 |
3003032 | 100187 | None | Code 034 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3) 6 Way | Each | 204.14 | 204.14 | 2.0 | False | None | None | False | None | False | 408.28 | 0 |
3003033 | 100187 | None | Code 035 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6) 16-18 Way | Each | 428.34 | 428.34 | 1.0 | False | None | None | False | None | False | 428.34 | 0 |
3003034 | 100187 | None | Code 036 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3) 6 Way | Each | 276.12 | 276.12 | 2.0 | False | None | None | False | None | False | 552.24 | 0 |
3003035 | 100187 | None | Code 037 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6) 16-18 Way | Each | 468.46 | 468.46 | 1.0 | False | None | None | False | None | False | 468.46 | 0 |
3003036 | 100187 | None | Code 038 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 1)6A One Way Switch | Each | 120.36 | 120.36 | 3.0 | False | None | None | False | None | False | 361.08 | 0 |
3003037 | 100187 | None | Code 039 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 4) Stepped Fan Regulator Two Module | Each | 421.26 | 421.26 | 3.0 | False | None | None | False | None | False | 1263.78 | 0 |
3003038 | 100187 | None | Code 040 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 8) 16A One Way Switch | Each | 212.4 | 212.4 | 2.0 | False | None | None | False | None | False | 424.8 | 0 |
3003039 | 100187 | None | Code 041 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 11) 6/16A Universal Socket | Each | 278.48 | 278.48 | 1.0 | False | None | None | False | None | False | 278.48 | 0 |
3003040 | 100187 | None | Code 042 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 13) RJ45/I.O Outlet Cat-6 | Each | 397.66 | 397.66 | 1.0 | False | None | None | False | None | False | 397.66 | 0 |
3003041 | 100187 | None | Code 043 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32 A SP | Each | 617.14 | 617.14 | 1.0 | False | None | None | False | None | False | 617.14 | 0 |
3003042 | 100187 | None | Code 044 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 3521.12 | 3521.12 | 2.0 | False | None | None | False | None | False | 7042.24 | 0 |
3003043 | 100187 | None | Code 045 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 371.7 | 371.7 | 2.0 | False | None | None | False | None | False | 743.4 | 0 |
3003044 | 100187 | None | Code 046 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 607.7 | 607.7 | 3.0 | False | None | None | False | None | False | 1823.1 | 0 |
3003045 | 100187 | None | Code 047 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diaw | Nos | 4141.8 | 4141.8 | 1.0 | False | None | None | False | None | False | 4141.8 | 0 |
3003046 | 100187 | None | Code 048 | Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. | Each | 1465.56 | 1465.56 | 1.0 | False | None | None | False | None | False | 1465.56 | 0 |
3003047 | 100187 | None | Code 049 | BESCOM Deposite including supervision and Agreement charges | Nos | 1180.0 | 1180.0 | 1.0 | False | None | None | False | None | False | 1180.0 | 0 |