2997209 | 99781 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 285.56 | 285.56 | 127.08 | False | None | None | False | None | False | 36288.9648 | 0 |
2997210 | 99781 | None | code02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 313.88 | 313.88 | 88.96 | False | None | None | False | None | False | 27922.7648 | 0 |
2997211 | 99781 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6683.52 | 6683.52 | 40.88 | False | None | None | False | None | False | 273222.2976 | 0 |
2997212 | 99781 | None | code04 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6620.98 | 6620.98 | 32.13 | False | None | None | False | None | False | 212732.0874 | 0 |
2997213 | 99781 | None | code05 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7321.9 | 7321.9 | 30.63 | False | None | None | False | None | False | 224269.797 | 0 |
2997214 | 99781 | None | code06 | Providing Flush/ Ruled pointing: Pointing on stone work with cement
mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin-
ing, including cost of materials, labour, curing as per specifications and as
per directions of Engineer-in-charge. | Sqm | 300.9 | 300.9 | 50.37 | False | None | None | False | None | False | 15156.333 | 0 |
2997215 | 99781 | None | code07 | Appendix I Additionalities for Formwork, Centering - 1. Foundation upto plinth a) Isolated - 8% | Cum | 625.87 | 625.87 | 32.84 | False | None | None | False | None | False | 20553.5708 | 0 |
2997216 | 99781 | None | code08 | Appendix I Additionalities for Formwork, Centering - 1.Plinth Beams of building a) Isolated - 50% | Cum | 3911.7 | 3911.7 | 13.24 | False | None | None | False | None | False | 51790.908 | 0 |
2997217 | 99781 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.) M20 Design Mix Using 20 mm nominal size graded crushed coarse | Cum | 7823.4 | 7823.4 | 47.02 | False | None | None | False | None | False | 367856.268 | 0 |
2997218 | 99781 | None | code10 | Appendix I Additionalities for Formwork, Centering - 8. CC Columns / Shaft (Slip Centering) - 70% | Cum | 5652.31 | 5652.31 | 10.87 | False | None | None | False | None | False | 61440.6097 | 0 |
2997219 | 99781 | None | code11 | Appendix I Additionalities for Formwork, Centering - 12. RCC Beams, Lintels & Troughs of Aqueducts Building - 60% | Cum | 4843.9 | 4843.9 | 19.8 | False | None | None | False | None | False | 95909.22 | 0 |
2997220 | 99781 | None | code12 | Appendix I Additionalities for Formwork, Centering - 15 RCC Roof Slabs - 50% | Cum | 4037.37 | 4037.37 | 35.29 | False | None | None | False | None | False | 142478.7873 | 0 |
2997221 | 99781 | None | code13 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | MT | 105559.26 | 105559.26 | 9.1935 | False | None | None | False | None | False | 970459.05681 | 0 |
2997222 | 99781 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8074.74 | 8074.74 | 64.68 | False | None | None | False | None | False | 522274.1832 | 0 |
2997223 | 99781 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9699.6 | 9699.6 | 61.7 | False | None | None | False | None | False | 598465.32 | 0 |
2997224 | 99781 | None | code16 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 300.9 | 300.9 | 499.53 | False | None | None | False | None | False | 150308.577 | 0 |
2997225 | 99781 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 348.1 | 348.1 | 363.94 | False | None | None | False | None | False | 126687.514 | 0 |
2997226 | 99781 | None | code18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm | Sqm | 1351.1 | 1351.1 | 210.08 | False | None | None | False | None | False | 283839.088 | 0 |
2997227 | 99781 | None | code19 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 205.32 | 205.32 | 363.94 | False | None | None | False | None | False | 74724.1608 | 0 |
2997228 | 99781 | None | code20 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 118.0 | 118.0 | 499.53 | False | None | None | False | None | False | 58944.54 | 0 |
2997229 | 99781 | None | code21 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 149.86 | 149.86 | 499.53 | False | None | None | False | None | False | 74859.5658 | 0 |
2997230 | 99781 | None | code22 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 5284.04 | 5284.04 | 10.08 | False | None | None | False | None | False | 53263.1232 | 0 |
2997231 | 99781 | None | code23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 198.24 | 198.24 | 364.56 | False | None | None | False | None | False | 72270.3744 | 0 |
2997232 | 99781 | None | code24 | Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metalsash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost: Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 51.92 | 51.92 | 329.28 | False | None | None | False | None | False | 17096.2176 | 0 |
2997233 | 99781 | None | code25 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 164.02 | 164.02 | 107.46 | False | None | None | False | None | False | 17625.5892 | 0 |
2997234 | 99781 | None | code26 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge. | Sqm | 162.84 | 162.84 | 299.25 | False | None | None | False | None | False | 48729.87 | 0 |
2997235 | 99781 | None | code27 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal exxpansion (i) Single socketed pipe 100 mm diameter | Mtr | 343.38 | 343.38 | 18.0 | False | None | None | False | None | False | 6180.84 | 0 |
2997236 | 99781 | None | code28 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 964.06 | 964.06 | 217.111 | False | None | None | False | None | False | 209308.03066 | 0 |
2997237 | 99781 | None | code29 | Providing and fixing precoated galvanised iron profile sheets (size, shapeand pitch of corrugation as approved by Engineer-in-charge) 0.50 mm(+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 asper IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on bothside of the sheet and polyester top coat 15-18 microns. Sheet shouldhave protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12m or as desired by Engineer-in-charge. The sheet shall be fixed usingself drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cuttingto size and shape wherever required..(Building SR 2022-23 Volume -2 Page No26 Iteam No7.38) | Sqm | 670.24 | 670.24 | 21.62 | False | None | None | False | None | False | 14490.5888 | 0 |
2997238 | 99781 | None | code30 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..(Building SR 2022-23 Volume -2 Page No 81 Iteam No 11.16.2)45mm Hollow square 4.5mm Thik 5.31kg/mtr | Kg | 173.46 | 173.46 | 196.36 | False | None | None | False | None | False | 34060.6056 | 0 |
2997239 | 99781 | None | code31 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 19/20 mm dia 2 mm thick | Mtr | 77.88 | 77.88 | 60.0 | False | None | None | False | None | False | 4672.8 | 0 |
2997240 | 99781 | None | code32 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20 mm dia 2 mm thick | Mtr | 80.24 | 80.24 | 60.0 | False | None | None | False | None | False | 4814.4 | 0 |
2997241 | 99781 | None | code33 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 3) 135 x 75 x 65 mm | Each | 253.7 | 253.7 | 4.0 | False | None | None | False | None | False | 1014.8 | 0 |
2997242 | 99781 | None | code34 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 7) 200 x 200 x 65 mm | Each | 410.64 | 410.64 | 2.0 | False | None | None | False | None | False | 821.28 | 0 |
2997243 | 99781 | None | code35 | Supplying and fixing PVC/metal conduit Deep junction box - 32 mm deep Junction box | Each | 71.98 | 71.98 | 10.0 | False | None | None | False | None | False | 719.8 | 0 |
2997244 | 99781 | None | code36 | Supplying And Fixing Metal Fan Box with Round Hook. | No | 138.06 | 138.06 | 6.0 | False | None | None | False | None | False | 828.36 | 0 |
2997245 | 99781 | None | code37 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 447.22 | 447.22 | 5.0 | False | None | None | False | None | False | 2236.1 | 0 |
2997246 | 99781 | None | code38 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. - 1.5 mm2 | Mtr | 30.68 | 30.68 | 120.0 | False | None | None | False | None | False | 3681.6 | 0 |
2997247 | 99781 | None | code39 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS694:2010 3C x 4 mm2 | Mtr | 202.96 | 202.96 | 40.0 | False | None | None | False | None | False | 8118.4 | 0 |
2997248 | 99781 | None | code40 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 3) 6 Way | Each | 204.14 | 204.14 | 4.0 | False | None | None | False | None | False | 816.56 | 0 |
2997249 | 99781 | None | code41 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete. 6) 16 Way | Each | 346.92 | 346.92 | 2.0 | False | None | None | False | None | False | 693.84 | 0 |
2997250 | 99781 | None | code42 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3) 6 Way | Each | 276.12 | 276.12 | 4.0 | False | None | None | False | None | False | 1104.48 | 0 |
2997251 | 99781 | None | code43 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6) 16 Way | Each | 468.46 | 468.46 | 2.0 | False | None | None | False | None | False | 936.92 | 0 |
2997252 | 99781 | None | code44 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 1)6A One Way Switch | Each | 120.36 | 120.36 | 6.0 | False | None | None | False | None | False | 722.16 | 0 |
2997253 | 99781 | None | code45 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 4) Stepped Fan Regulator Two Module | Each | 421.26 | 421.26 | 4.0 | False | None | None | False | None | False | 1685.04 | 0 |
2997254 | 99781 | None | code46 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 8) 16A One Way Switch | Each | 212.4 | 212.4 | 3.0 | False | None | None | False | None | False | 637.2 | 0 |
2997255 | 99781 | None | code47 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 11) 6/16A Universal Socket | Each | 278.48 | 278.48 | 2.0 | False | None | None | False | None | False | 556.96 | 0 |
2997256 | 99781 | None | code48 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 13) RJ45/I.O Outlet Cat-6 | Each | 397.66 | 397.66 | 2.0 | False | None | None | False | None | False | 795.32 | 0 |
2997257 | 99781 | None | code49 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 4 Way | Each | 12188.22 | 12188.22 | 1.0 | False | None | None | False | None | False | 12188.22 | 0 |
2997258 | 99781 | None | code50 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32 A SP | Each | 489.7 | 489.7 | 2.0 | False | None | None | False | None | False | 979.4 | 0 |
2997259 | 99781 | None | code51 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system. 48" Sweep (1200 mm) Regular model | Each | 3521.12 | 3521.12 | 6.0 | False | None | None | False | None | False | 21126.72 | 0 |
2997260 | 99781 | None | code52 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 371.7 | 371.7 | 6.0 | False | None | None | False | None | False | 2230.2 | 0 |
2997261 | 99781 | None | code53 | Supplying of .feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & lumen maintenance with CRI Power Input: 220-240V@ 50/60Hz & Power factor along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 20/22 W | Each | 814.2 | 814.2 | 10.0 | False | None | None | False | None | False | 8142.0 | 0 |
2997262 | 99781 | None | code54 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia | No | 4141.8 | 4141.8 | 1.0 | False | None | None | False | None | False | 4141.8 | 0 |