2884041 | 94333 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m complete with all lead and lift and as per the directions of engineer in charge. | Cum | 73.0 | 73.0 | 408.34 | False | None | None | False | None | False | 29808.82 | 0 |
2884042 | 94333 | None | 002 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates complete with all lead and lift and as per the directions of engineer in charge. | Cum | 5554.0 | 5554.0 | 50.38 | False | None | None | False | None | False | 279810.52 | 0 |
2884043 | 94333 | None | 003 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Footing including including Formwork, Centering and Scaffolding complete with all lead and lift and as per the directions of engineer in charge. | Cum | 6445.44 | 6445.44 | 44.66 | False | None | None | False | None | False | 287853.3504 | 0 |
2884044 | 94333 | None | 004 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns including including Formwork, Centering and Scaffolding complete with all lead and lift and as per the directions of engineer in charge. | Cum | 10145.6 | 10145.6 | 7.1 | False | None | None | False | None | False | 72033.76 | 0 |
2884045 | 94333 | None | 005 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for RCC Walls including including Formwork, Centering and Scaffolding complete with all lead and lift and as per the directions of engineer in charge. | Cum | 8056.8 | 8056.8 | 51.85 | False | None | None | False | None | False | 417745.08 | 0 |
2884046 | 94333 | None | 006 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : complete with all lead and lift and as per the directions of engineer in charge. | Cum | 4750.0 | 4750.0 | 63.14 | False | None | None | False | None | False | 299915.0 | 0 |
2884047 | 94333 | None | 007 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for Columns complete with all lead and lift and as per the directions of engineer in charge. | Cum | 10509.4 | 10509.4 | 19.27 | False | None | None | False | None | False | 202516.138 | 0 |
2884048 | 94333 | None | 008 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for plinth beam complete with all lead and lift and as per the directions of engineer in charge. | Cum | 9273.0 | 9273.0 | 28.78 | False | None | None | False | None | False | 266876.94 | 0 |
2884049 | 94333 | None | 009 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for roof beam complete with all lead and lift and as per the directions of engineer in charge. | Cum | 9891.2 | 9891.2 | 32.03 | False | None | None | False | None | False | 316815.136 | 0 |
2884050 | 94333 | None | 010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for Lintle beam complete with all lead and lift and as per the directions of engineer in charge. | Cum | 9891.2 | 9891.2 | 6.65 | False | None | None | False | None | False | 65776.48 | 0 |
2884051 | 94333 | None | 011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for Chejja complete with all lead and lift and as per the directions of engineer in charge. | Cum | 8963.9 | 8963.9 | 0.97 | False | None | None | False | None | False | 8694.983 | 0 |
2884052 | 94333 | None | 012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for roof slab complete with all lead and lift and as per the directions of engineer in charge. | Cum | 9273.0 | 9273.0 | 69.88 | False | None | None | False | None | False | 647997.24 | 0 |
2884053 | 94333 | None | 013 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates including including Formwork, Centering and Scaffolding for stair case complete with all lead and lift and as per the directions of engineer in charge. | Cum | 9273.0 | 9273.0 | 2.8 | False | None | None | False | None | False | 25964.4 | 0 |
2884054 | 94333 | None | 014 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) complete with all lead and lift and as per the directions of engineer in charge. | Kg | 92.0 | 92.0 | 17138.4 | False | None | None | False | None | False | 1576732.8 | 0 |
2884055 | 94333 | None | 015 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete with all lead and lift and as per the directions of engineer in charge. | Cum | 204.0 | 204.0 | 473.23 | False | None | None | False | None | False | 96538.92 | 0 |
2884056 | 94333 | None | 016 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. complete with all lead and lift and as per the directions of engineer in charge. | Cum | 6690.0 | 6690.0 | 106.01 | False | None | None | False | None | False | 709206.9 | 0 |
2884057 | 94333 | None | 017 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 1196.0 | 1196.0 | 191.21 | False | None | None | False | None | False | 228687.16 | 0 |
2884058 | 94333 | None | 018 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 213.0 | 213.0 | 1211.83 | False | None | None | False | None | False | 258119.79 | 0 |
2884059 | 94333 | None | 019 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 322.0 | 322.0 | 1228.26 | False | None | None | False | None | False | 395499.72 | 0 |
2884060 | 94333 | None | 020 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 83.0 | 83.0 | 713.78 | False | None | None | False | None | False | 59243.74 | 0 |
2884061 | 94333 | None | 021 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 40.0 | 40.0 | 1211.83 | False | None | None | False | None | False | 48473.2 | 0 |
2884062 | 94333 | None | 022 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 95.0 | 95.0 | 1211.83 | False | None | None | False | None | False | 115123.85 | 0 |
2884063 | 94333 | None | 023 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm ) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 132.0 | 132.0 | 613.49 | False | None | None | False | None | False | 80980.68 | 0 |
2884064 | 94333 | None | 024 | Finishing walls with water proofing cement paint of required shade : New work (Two coats applied @ 4.84 kg/10 sqm) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 66.0 | 66.0 | 522.25 | False | None | None | False | None | False | 34468.5 | 0 |
2884065 | 94333 | None | 025 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 1192.0 | 1192.0 | 447.11 | False | None | None | False | None | False | 532955.12 | 0 |
2884066 | 94333 | None | 026 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications complete with all lead and lift and as per the directions of engineer in charge. | Cum | 75344.0 | 75344.0 | 0.64 | False | None | None | False | None | False | 48220.16 | 0 |
2884067 | 94333 | None | 027 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 4556.0 | 4556.0 | 19.31 | False | None | None | False | None | False | 87976.36 | 0 |
2884068 | 94333 | None | 028 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. complete with all lead and lift and as per the directions of engineer in charge. | No | 1485.0 | 1485.0 | 11.0 | False | None | None | False | None | False | 16335.0 | 0 |
2884069 | 94333 | None | 029 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding. complete with all lead and lift and as per the directions of engineer in charge. | Kg | 131.0 | 131.0 | 1134.0 | False | None | None | False | None | False | 148554.0 | 0 |
2884070 | 94333 | None | 030 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm. Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P’s shall not be made) complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 4114.0 | 4114.0 | 63.0 | False | None | None | False | None | False | 259182.0 | 0 |
2884071 | 94333 | None | 031 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPE (Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 4870.0 | 4870.0 | 100.8 | False | None | None | False | None | False | 490896.0 | 0 |
2884072 | 94333 | None | 032 | Providing and fixing chorinated poly vinyle chloride (CPVC) pipes, having theramel stebility for hot and cold water supply including all CPVC plain and bross threaded fitting. This includes jointing of pipes and fittings with one step CPVC solvent cement trenching, reffling & testing of joints complete. External work. 40mm nominal OD pipes complete with all lead and lift and as per the directions of engineer in charge. | m | 469.0 | 469.0 | 50.0 | False | None | None | False | None | False | 23450.0 | 0 |
2884073 | 94333 | None | 033 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 90.0 | 90.0 | 69.3 | False | None | None | False | None | False | 6237.0 | 0 |
2884074 | 94333 | None | 034 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. complete with all lead and lift and as per the directions of engineer in charge. | Each | 1005.0 | 1005.0 | 3.0 | False | None | None | False | None | False | 3015.0 | 0 |
2884075 | 94333 | None | 035 | Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. complete with all lead and lift and as per the directions of engineer in charge. | Each | 2433.0 | 2433.0 | 3.0 | False | None | None | False | None | False | 7299.0 | 0 |
2884076 | 94333 | None | 036 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm. complete with all lead and lift and as per the directions of engineer in charge. | Each | 2159.0 | 2159.0 | 2.0 | False | None | None | False | None | False | 4318.0 | 0 |
2884077 | 94333 | None | 037 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6mm nominal size) as per direction of Engineer-in- charge and finished smooth. complete with all lead and lift and as per the directions of engineer in charge. | Sqm | 1612.0 | 1612.0 | 2.97 | False | None | None | False | None | False | 4787.64 | 0 |
2884078 | 94333 | None | 038 | Providing and fixing Cl Nahani trap of approved make conforming to lSI specifications and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot). 12.5cms x 7.5cms. complete with all lead and lift and as per the directions of engineer in charge. | Each | 285.0 | 285.0 | 5.0 | False | None | None | False | None | False | 1425.0 | 0 |
2884079 | 94333 | None | 039 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases and making good the same including testing of joints as per the direction of engineer in charge. Concealed work including cutting chases and making good the walls etc. 25mm nominal OD pipes. complete with all lead and lift and as per the directions of engineer in charge. | m | 476.0 | 476.0 | 40.0 | False | None | None | False | None | False | 19040.0 | 0 |
2884080 | 94333 | None | 040 | Providing and fixing chorinated poly vinyle chloride (CPVC) pipes, having theramel stebility for hot and cold water supply including all CPVC plain and bross threaded fitting. This includes jointing of pipes and fittings with one step CPVC solvent cement trenching, reffling & testing of joints complete. External work. 40mm nominal OD pipes. complete with all lead and lift and as per the directions of engineer in charge. | m | 469.0 | 469.0 | 30.0 | False | None | None | False | None | False | 14070.0 | 0 |
2884081 | 94333 | None | 041 | Providing and placing on terrace (at all floor levels), polyethylene water storage tanks IS:12701 marked, with with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. complete with all lead and lift and as per the directions of engineer in charge. | l | 8.0 | 8.0 | 2500.0 | False | None | None | False | None | False | 20000.0 | 0 |
2884082 | 94333 | None | 042 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. complete with all lead and lift and as per the directions of engineer in charge. | Kg | 108.0 | 108.0 | 177.17 | False | None | None | False | None | False | 19134.36 | 0 |
2884083 | 94333 | None | 043 | Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. 125mm. complete with all lead and lift and as per the directions of engineer in charge. | No | 189.0 | 189.0 | 54.0 | False | None | None | False | None | False | 10206.0 | 0 |
2884084 | 94333 | None | 044 | Providing and fixing Hold fasts M.S. for doors etc complete. (Material Components P.No -A21 I.No 285 ). complete with all lead and lift and as per the directions of engineer in charge. | Each | 32.0 | 32.0 | 36.0 | False | None | None | False | None | False | 1152.0 | 0 |
2884085 | 94333 | None | 045 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete complete with all lead and lift and as per the directions of engineer in charge. | Each | 175.0 | 175.0 | 18.0 | False | None | None | False | None | False | 3150.0 | 0 |
2884086 | 94333 | None | 046 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. complete with all lead and lift and as per the directions of engineer in charge. | No | 621.0 | 621.0 | 9.0 | False | None | None | False | None | False | 5589.0 | 0 |
2884087 | 94333 | None | 047 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. complete with all lead and lift and as per the directions of engineer in charge. | No | 111.0 | 111.0 | 18.0 | False | None | None | False | None | False | 1998.0 | 0 |
2884088 | 94333 | None | 048 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. complete with all lead and lift and as per the directions of engineer in charge. | No | 109.0 | 109.0 | 9.0 | False | None | None | False | None | False | 981.0 | 0 |
2884089 | 94333 | None | 049 | Concealed Conduit System: Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thick complete with all lead and lift and as per the directions of engineer in charge. | m | 61.0 | 61.0 | 80.0 | False | None | None | False | None | False | 4880.0 | 0 |
2884090 | 94333 | None | 050 | Concealed Conduit System: Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick complete with all lead and lift and as per the directions of engineer in charge. | m | 75.0 | 75.0 | 25.0 | False | None | None | False | None | False | 1875.0 | 0 |
2884091 | 94333 | None | 051 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. a) Short point upto 3m from tapping point to out let via switch complete with all lead and lift and as per the directions of engineer in charge. | Point | 276.0 | 276.0 | 30.0 | False | None | None | False | None | False | 8280.0 | 0 |
2884092 | 94333 | None | 052 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. b) Medium point above 3m upto 6m from tapping point to out let via switch complete with all lead and lift and as per the directions of engineer in charge. | Point | 386.0 | 386.0 | 10.0 | False | None | None | False | None | False | 3860.0 | 0 |
2884093 | 94333 | None | 053 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. c) Long point above 6m upto 10m from tapping point to out let via switch complete with all lead and lift and as per the directions of engineer in charge. | Point | 567.0 | 567.0 | 10.0 | False | None | None | False | None | False | 5670.0 | 0 |
2884094 | 94333 | None | 054 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments a) 1.5 sq mm complete with all lead and lift and as per the directions of engineer in charge. | m | 26.0 | 26.0 | 350.0 | False | None | None | False | None | False | 9100.0 | 0 |
2884095 | 94333 | None | 055 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments b) 2.5 sq mm complete with all lead and lift and as per the directions of engineer in charge. | m | 40.0 | 40.0 | 70.0 | False | None | None | False | None | False | 2800.0 | 0 |
2884096 | 94333 | None | 056 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way complete with all lead and lift and as per the directions of engineer in charge. | Each | 123.0 | 123.0 | 30.0 | False | None | None | False | None | False | 3690.0 | 0 |
2884097 | 94333 | None | 057 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6 Way complete with all lead and lift and as per the directions of engineer in charge. | Each | 212.0 | 212.0 | 15.0 | False | None | None | False | None | False | 3180.0 | 0 |
2884098 | 94333 | None | 058 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 1 to 3 Module complete with all lead and lift and as per the directions of engineer in charge. | Each | 152.0 | 152.0 | 30.0 | False | None | None | False | None | False | 4560.0 | 0 |
2884099 | 94333 | None | 059 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module complete with all lead and lift and as per the directions of engineer in charge. | Each | 175.0 | 175.0 | 25.0 | False | None | None | False | None | False | 4375.0 | 0 |
2884100 | 94333 | None | 060 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module complete with all lead and lift and as per the directions of engineer in charge. | Each | 244.0 | 244.0 | 15.0 | False | None | None | False | None | False | 3660.0 | 0 |
2884101 | 94333 | None | 061 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps One Way Switch complete with all lead and lift and as per the directions of engineer in charge. | Each | 88.0 | 88.0 | 30.0 | False | None | None | False | None | False | 2640.0 | 0 |
2884102 | 94333 | None | 062 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps One Way Switch 6A Three Way socket complete with all lead and lift and as per the directions of engineer in charge. | Each | 162.0 | 162.0 | 25.0 | False | None | None | False | None | False | 4050.0 | 0 |
2884103 | 94333 | None | 063 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module complete with all lead and lift and as per the directions of engineer in charge. | Each | 313.0 | 313.0 | 16.0 | False | None | None | False | None | False | 5008.0 | 0 |
2884104 | 94333 | None | 064 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket complete with all lead and lift and as per the directions of engineer in charge. | Each | 249.0 | 249.0 | 5.0 | False | None | None | False | None | False | 1245.0 | 0 |
2884105 | 94333 | None | 065 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch complete with all lead and lift and as per the directions of engineer in charge. | Each | 375.0 | 375.0 | 2.0 | False | None | None | False | None | False | 750.0 | 0 |
2884106 | 94333 | None | 066 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 20 mm complete with all lead and lift and as per the directions of engineer in charge. | m | 25.0 | 25.0 | 50.0 | False | None | None | False | None | False | 1250.0 | 0 |
2884107 | 94333 | None | 067 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Bakelite Ceiling Rose complete with all lead and lift and as per the directions of engineer in charge. | No | 63.0 | 63.0 | 35.0 | False | None | None | False | None | False | 2205.0 | 0 |
2884108 | 94333 | None | 068 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 6A Lamp Holder complete with all lead and lift and as per the directions of engineer in charge. | No | 63.0 | 63.0 | 10.0 | False | None | None | False | None | False | 630.0 | 0 |
2884109 | 94333 | None | 069 | Supplying and fixing of slim patty fitting, made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Fluorescent Tube. 1 x 4' Tube light fitting. complete with all lead and lift and as per the directions of engineer in charge. | Each | 243.0 | 243.0 | 30.0 | False | None | None | False | None | False | 7290.0 | 0 |
2884110 | 94333 | None | 070 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, deliveringsuperior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70 percentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection - Min 5KV along with Over voltage/Overload, short circuit / miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with System Power consumption. LED Efficiency 1301 m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned. LED Streetlight 120 W complete with all lead and lift and as per the directions of engineer in charge. | No | 9998.0 | 9998.0 | 1.0 | False | None | None | False | None | False | 9998.0 | 0 |
2884111 | 94333 | None | 071 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires. Using 32mm dia G.I.Pipe complete with all lead and lift and as per the directions of engineer in charge. | Each | 902.0 | 902.0 | 1.0 | False | None | None | False | None | False | 902.0 | 0 |
2884112 | 94333 | None | 072 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. complete with all lead and lift and as per the directions of engineer in charge. | Each | 281.0 | 281.0 | 16.0 | False | None | None | False | None | False | 4496.0 | 0 |
2884113 | 94333 | None | 073 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. - 32Amps complete with all lead and lift and as per the directions of engineer in charge. | Each | 200.0 | 200.0 | 4.0 | False | None | None | False | None | False | 800.0 | 0 |
2884114 | 94333 | None | 074 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT complete with all lead and lift and as per the directions of engineer in charge. | Each | 1512.0 | 1512.0 | 1.0 | False | None | None | False | None | False | 1512.0 | 0 |
2884115 | 94333 | None | 075 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps SP complete with all lead and lift and as per the directions of engineer in charge. | Each | 523.0 | 523.0 | 10.0 | False | None | None | False | None | False | 5230.0 | 0 |
2884116 | 94333 | None | 076 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP complete with all lead and lift and as per the directions of engineer in charge. | Each | 1103.0 | 1103.0 | 5.0 | False | None | None | False | None | False | 5515.0 | 0 |
2884117 | 94333 | None | 077 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps TPN complete with all lead and lift and as per the directions of engineer in charge. | Each | 1777.0 | 1777.0 | 2.0 | False | None | None | False | None | False | 3554.0 | 0 |
2884118 | 94333 | None | 078 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door, 4 Way TP & N complete with all lead and lift and as per the directions of engineer in charge. | Each | 5744.0 | 5744.0 | 1.0 | False | None | None | False | None | False | 5744.0 | 0 |
2884119 | 94333 | None | 079 | G I Grounding pipe, B-Class, 42 mm dia, 2.50 Mtr long, 3.2 mm thick with bolt, nut, GI strips and washers complete . Minimum weight of GI pipe : 7.3 Kg. complete with all lead and lift and as per the directions of engineer in charge. | No | 770.0 | 770.0 | 1.0 | False | None | None | False | None | False | 770.0 | 0 |
2884120 | 94333 | None | 080 | Good quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. complete with all lead and lift and as per the directions of engineer in charge. | No | 660.0 | 660.0 | 1.0 | False | None | None | False | None | False | 660.0 | 0 |
2884121 | 94333 | None | 081 | Good quality Salt for grounding purposes packed in 50 Kg gunny bag. complete with all lead and lift and as per the directions of engineer in charge. | Bag | 303.0 | 303.0 | 1.0 | False | None | None | False | None | False | 303.0 | 0 |
2884122 | 94333 | None | 082 | Digging pit for G I Pipe tye earthing in Hard soil complete with all lead and lift and as per the directions of engineer in charge. | Per Pit | 2267.0 | 2267.0 | 1.0 | False | None | None | False | None | False | 2267.0 | 0 |