createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1710332367863
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee3270.00
emd200000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose28-03-2024 16:00:00
tenderQueryClose21-03-2024 16:00:00
technicalBidOpen30-03-2024 16:00:00
publishedDate13-03-2024 19:28:18
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate22-03-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1710332367957
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2023-24/BD/WORK_INDENT216
titleConstruction of Post Metric Girls Hostel 2nd Phase at Barkur, Udupi District
descriptionConstruction of Post Metric Girls Hostel 2nd Phase at Barkur, Udupi District
categoryWORKS
categoryTextWorks
ecv13070752.98
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount13070753.0
groupOverheadTotalNone
fileNumber768/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17103323680000NoneNoneBuildingsConstruction of Post Metric Girls Hostel 2nd Phase at Barkur, Udupi District13070752.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3047455103016Nonecode01Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(vol-I-pg no:15 Item no:2.1.4)-First floor sill concreteCum7032.677032.671.12FalseNoneNoneFalseNoneFalse7876.59040
3047456103016Nonecode02Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(vol-I-pg no:15 Item no:2.1.4)-Second floor sill concreteCum7102.37102.32.61FalseNoneNoneFalseNoneFalse18537.0030
3047457103016Nonecode03Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(vol-I-pg no:15 Item no:2.1.4)-Second floor Dummy columnCum12769.9412769.941.04FalseNoneNoneFalseNoneFalse13280.73760
3047458103016Nonecode04Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite /trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates(vol-I-pg no:15 Item no:2.1.4)-Terrace floor screed concreteCum7171.937171.939.53FalseNoneNoneFalseNoneFalse68348.49290
3047459103016Nonecode05Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)- First floor columnCum13809.5913809.598.75FalseNoneNoneFalseNoneFalse120833.91250
3047460103016Nonecode06Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)- second floor columnCum14055.7614055.768.26FalseNoneNoneFalseNoneFalse116100.57760
3047461103016Nonecode07Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)- Light roof columnCum14055.7614055.7610.91FalseNoneNoneFalseNoneFalse153348.34160
3047462103016Nonecode08Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)- Headroom columnCum14055.7614055.761.08FalseNoneNoneFalseNoneFalse15180.22080
3047463103016Nonecode09Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)-First floor beamCum12942.6212942.6217.04FalseNoneNoneFalseNoneFalse220542.24480
3047464103016Nonecode10Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.2)-Second floor beamCum13164.5713164.5712.56FalseNoneNoneFalseNoneFalse165346.99920
3047465103016Nonecode11Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)-slabCum11496.2411496.2422.38FalseNoneNoneFalseNoneFalse257285.85120
3047466103016Nonecode12Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.2)-First floor slabCum12075.6512075.6537.59FalseNoneNoneFalseNoneFalse453923.68350
3047467103016Nonecode13Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.2)- second floor slabCum12273.3912273.3915.95FalseNoneNoneFalseNoneFalse195760.57050
3047468103016Nonecode14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.2)-HeadroomCum12393.7112393.714.5FalseNoneNoneFalseNoneFalse55771.6950
3047469103016Nonecode15Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)-LintelCum12262.6612262.660.28FalseNoneNoneFalseNoneFalse3433.54480
3047470103016Nonecode16Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) (Grade M25) (vol-I-pg no:17 Item no:2.5.2)-Lintel first floorCum12942.6212942.623.83FalseNoneNoneFalseNoneFalse49570.23460
3047471103016Nonecode17Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.2)-Lintel second floorCum13164.5713164.572.6FalseNoneNoneFalseNoneFalse34227.8820
3047472103016Nonecode18Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.2)-second floor staircaseCum12273.3912273.394.38FalseNoneNoneFalseNoneFalse53757.44820
3047473103016Nonecode19Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)(Grade M25) (vol-I-pg no:17 Item no:2.5.1)-First floor chajjaCum11279.7811279.783.21FalseNoneNoneFalseNoneFalse36208.09380
3047474103016Nonecode20Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)) (Grade M25) (vol-I-pg no:17 Item no:2.5.1)- second floor chajjaCum11459.6311459.630.57FalseNoneNoneFalseNoneFalse6531.98910
3047475103016Nonecode21Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (vol-I-pg no:18 Item no:2.11.a)Tonne100191.84100191.842.2FalseNoneNoneFalseNoneFalse220422.0480
3047476103016Nonecode22Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (vol-I-pg no:18 Item no:2.11.a)-First floorTonne101193.76101193.769.92FalseNoneNoneFalseNoneFalse1003842.09920
3047477103016Nonecode23Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (vol-I-pg no:18 Item no:2.11.a)-second floorTonne102195.68102195.6811.17FalseNoneNoneFalseNoneFalse1141525.74560
3047478103016Nonecode24Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (vol-I-pg no:18 Item no:2.11.a)-Terrace floorTonne103197.6103197.60.64FalseNoneNoneFalseNoneFalse66046.4640
3047479103016Nonecode25Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.(Vol-II-Pg.no-09- Item no-5.7) First floor-200mm thick wallCum7641.267641.2656.92FalseNoneNoneFalseNoneFalse434940.51920
3047480103016Nonecode26Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.(Vol-II-Pg.no-09- Item no-5.7)-Second floor-200mm thick wallCum7716.917716.9140.88FalseNoneNoneFalseNoneFalse315467.28080
3047481103016Nonecode27Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6.(Vol-II-Pg.no-09- Item no-5.7)-Second floor-150mm thick wallCum7716.917716.9113.91FalseNoneNoneFalseNoneFalse107342.21810
3047482103016Nonecode28Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(vol-II-Pg.no-17-Item no-6.34)Sqm1248.841248.8479.28FalseNoneNoneFalseNoneFalse99008.03520
3047483103016Nonecode29Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Inside walls) (vol-II-Pg.no-42-Item no-8.7)-First floorSqm414.02414.02508.1825FalseNoneNoneFalseNoneFalse210397.718650
3047484103016Nonecode30Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Inside walls) (vol-II-Pg.no-42-Item no-8.7) second floorSqm418.12418.12348.07FalseNoneNoneFalseNoneFalse145535.02840
3047485103016Nonecode31Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External (vol-II-Pg.no-42-Item no-8.8) First floorSqm419.68419.68202.93FalseNoneNoneFalseNoneFalse85165.66240
3047486103016Nonecode32Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External (vol-II-Pg.no-42-Item no-8.8)Second floorSqm423.83423.83412.44FalseNoneNoneFalseNoneFalse174804.44520
3047487103016Nonecode33Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Inside rough Plastering) (vol-II-Pg.no-42-Item no-8.7)Sqm409.92409.9213.44FalseNoneNoneFalseNoneFalse5509.32480
3047488103016Nonecode34Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Inside rough Plastering) (vol-II-Pg.no-42-Item no-8.7)-First floorSqm414.02414.02160.76FalseNoneNoneFalseNoneFalse66557.85520
3047489103016Nonecode35Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling) (vol-II-Pg.no-41-Item no-8.4.1)-Sqm361.76361.76127.08FalseNoneNoneFalseNoneFalse45972.46080
3047490103016Nonecode36Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling) (vol-II-Pg.no-41-Item no-8.4.1)- first floorSqm365.38365.38301.25FalseNoneNoneFalseNoneFalse110070.7250
3047491103016Nonecode37Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling) (vol-II-Pg.no-41-Item no-8.4.1)- second floorSqm369.0369.0136.1FalseNoneNoneFalseNoneFalse50220.90
3047492103016Nonecode38Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling) (vol-II-Pg.no-41-Item no-8.4.1)- Terrace floorSqm372.61372.6127.0FalseNoneNoneFalseNoneFalse10060.470
3047493103016Nonecode39Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide (vol-II-Pg.no-42-Item no-8.16.2)Sqm42.5642.56876.4FalseNoneNoneFalseNoneFalse37299.5840
3047494103016Nonecode40Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(75x125mm) (vol-II-Pg.no-100-Item no-12.13.2) first floorCum112667.52112667.520.93FalseNoneNoneFalseNoneFalse104780.79360
3047495103016Nonecode41Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(75x125mm) (vol-II-Pg.no-100-Item no-12.13.2) Second floorCum113783.04113783.040.23FalseNoneNoneFalseNoneFalse26170.09920
3047496103016Nonecode42Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (vol-II-Pg.no-104-Item no-12.51)Nos1137.921137.9220.0FalseNoneNoneFalseNoneFalse22758.40
3047497103016Nonecode43Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial (vol-II-Pg.no-105-Item no-12.57.6)-First floorSqm3757.853757.8515.36FalseNoneNoneFalseNoneFalse57720.5760
3047498103016Nonecode44Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial (vol-II-Pg.no-105-Item no-12.57.6)-second floorSqm3795.053795.057.2FalseNoneNoneFalseNoneFalse27324.360
3047499103016Nonecode45Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 30mm thick both side commercial and laminated (vol-II-Pg.no-105-Item no-12.57.3)-Sqm3365.63365.61.68FalseNoneNoneFalseNoneFalse5654.2080
3047500103016Nonecode46Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 30mm thick both side commercial and laminated (vol-II-Pg.no-105-Item no-12.57.3)-First floorSqm3399.263399.2618.48FalseNoneNoneFalseNoneFalse62818.32480
3047501103016Nonecode47Providing and fixing ISI marked oxidised M.S.Handles confirming to IS: 4992 with necessary screws etc. complete. (Only For Toilet Doors) (vol-II-Pg.no-107-Item no-12.73.1)Nos49.2849.2824.0FalseNoneNoneFalseNoneFalse1182.720
3047502103016Nonecode48Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.-125x65x2.12mm.(For toilet doors)(vol-II-Pg.no-106-Item no-12.68.1)Nos61.661.684.0FalseNoneNoneFalseNoneFalse5174.40
3047503103016Nonecode49Providing and fixing MS Hold fasts (For all the doors))(vol-II-A-25-Item no-444)Nos56.056.0120.0FalseNoneNoneFalseNoneFalse6720.00
3047504103016Nonecode50Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plainfloat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(vol-II-Pg.no-110-Item no-12.89)Sqm7337.127337.1213.05FalseNoneNoneFalseNoneFalse95749.4160
3047505103016Nonecode51Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plainfloat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(vol-II-Pg.no-110-Item no-12.89)-First floorSqm7410.497410.4924.57FalseNoneNoneFalseNoneFalse182075.73930
3047506103016Nonecode52Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plainfloat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(vol-II-Pg.no-110-Item no-12.89)-second floorSqm7483.867483.8615.91FalseNoneNoneFalseNoneFalse119068.21260
3047507103016Nonecode53Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. (vol-II-Pg.no-89-Item no-11.37.2)-First floorSqm1324.641324.6411.43FalseNoneNoneFalseNoneFalse15140.63520
3047508103016Nonecode54Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. (vol-II-Pg.no-89-Item no-11.37.2)-Second floorSqm1337.751337.754.5FalseNoneNoneFalseNoneFalse6019.8750
3047509103016Nonecode55Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (vol-II-Pg.no-86-Item no-11.34A)-First floorKg190.04190.04715.68FalseNoneNoneFalseNoneFalse136007.82720
3047510103016Nonecode56Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (vol-II-Pg.no-86-Item no-11.34A)-Second floorKg191.92191.92428.61FalseNoneNoneFalseNoneFalse82258.83120
3047511103016Nonecode57Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (vol-II-Pg.no-77-Item no-11.5.1)-Second floorSqm5115.675115.674.2FalseNoneNoneFalseNoneFalse21485.8140
3047512103016Nonecode58Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (vol-II-Pg.no-85-Item no-11.28)-Second floorKg645.46645.4686.4FalseNoneNoneFalseNoneFalse55767.7440
3047513103016Nonecode59Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets (vol-II-Pg.no-106-Item no-12.67.1)m471.52471.5264.8FalseNoneNoneFalseNoneFalse30554.4960
3047514103016Nonecode60Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (vol-II-Pg.no-61-Item no-9.17.2)Sqm1316.01316.033.6FalseNoneNoneFalseNoneFalse44217.60
3047515103016Nonecode61Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (vol-II-Pg.no-61-Item no-9.17.2)-First floorSqm1329.161329.16130.3FalseNoneNoneFalseNoneFalse173189.5480
3047516103016Nonecode62Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (vol-II-Pg.no-61-Item no-9.17.2)-second floorSqm1342.321342.3279.44FalseNoneNoneFalseNoneFalse106633.90080
3047517103016Nonecode63Providing and laying flooring and steps machine cut granite slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar labour, curing complete as per specifications. (vol-II-Pg.no-63-Item no-9.28)Sqm4888.334888.330.54FalseNoneNoneFalseNoneFalse2639.69820
3047518103016Nonecode64Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (vol-II-Pg.no-63-Item no-9.24Sqm3194.243194.2446.77FalseNoneNoneFalseNoneFalse149394.60480
3047519103016Nonecode65Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (vol-II-Pg.no-63-Item no-9.24)-First floorSqm3226.183226.1863.48FalseNoneNoneFalseNoneFalse204797.90640
3047520103016Nonecode66Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (vol-II-Pg.no-63-Item no-9.24)-second floorSqm3258.123258.1243.33FalseNoneNoneFalseNoneFalse141174.33960
3047521103016Nonecode67Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. area of slab over0.5 m2 (vol-II-Pg.no-69-Item no-10.19)Sqm4409.444409.4419.08FalseNoneNoneFalseNoneFalse84132.11520
3047522103016Nonecode68Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. area of slab over0.5 m2 (vol-II-Pg.no-69-Item no-10.19)-First floorSqm4453.534453.533.9FalseNoneNoneFalseNoneFalse17368.7670
3047523103016Nonecode69Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (vol-II-Pg.no-60-Item no-9.11)Sqm995.68995.683.08FalseNoneNoneFalseNoneFalse3066.69440
3047524103016Nonecode70Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (vol-II-Pg.no-60-Item no-9.11)-First floorSqm1005.641005.6434.5FalseNoneNoneFalseNoneFalse34694.580
3047525103016Nonecode71Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (vol-II-Pg.no-65-Item no-9.39)Sqm1622.881622.8847.5FalseNoneNoneFalseNoneFalse77086.80
3047526103016Nonecode72Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (vol-II-Pg.no-65-Item no-9.39)-First floorSqm1639.111639.11160.76FalseNoneNoneFalseNoneFalse263503.32360
3047527103016Nonecode73Providing and laying chequerred precast cement concrete concrete tiles 22mm thick in footpath & courtyard ,jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc., complete, on 20mm thick bed of cement mortar 1:4 (Medium shade pigment using 50% white cement 50% grey cement) (vol-II-Pg.no-59-Item no-9.6.2)Sqm1227.761227.7612.6FalseNoneNoneFalseNoneFalse15469.7760
3047528103016Nonecode74Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (vol-II-Pg.no-48-Item no-8.4.1)-First floorSqm188.91188.9134.08FalseNoneNoneFalseNoneFalse6438.05280
3047529103016Nonecode75Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (vol-II-Pg.no-48-Item no-8.4.1)-Second floorSqm190.78190.7820.41FalseNoneNoneFalseNoneFalse3893.81980
3047530103016Nonecode76Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (vol-II-Pg.no-50-Item no-8.51)Sqm112.0112.0127.08FalseNoneNoneFalseNoneFalse14232.960
3047531103016Nonecode77Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (vol-II-Pg.no-50-Item no-8.51)-First floorSqm113.12113.12813.59FalseNoneNoneFalseNoneFalse92033.30080
3047532103016Nonecode78Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (vol-II-Pg.no-50-Item no-8.51)-second floorSqm114.24114.24484.17FalseNoneNoneFalseNoneFalse55311.58080
3047533103016Nonecode79Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (vol-II-Pg.no-50-Item no-8.51)-Terrace floorSqm115.36115.3627.0FalseNoneNoneFalseNoneFalse3114.720
3047534103016Nonecode80Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (vol-II-Pg.no-46-Item no-8.33.1)Sqm176.96176.96127.08FalseNoneNoneFalseNoneFalse22488.07680
3047535103016Nonecode81Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (vol-II-Pg.no-46-Item no-8.33.1)-first floorSqm178.73178.73813.59FalseNoneNoneFalseNoneFalse145412.94070
3047536103016Nonecode82Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (vol-II-Pg.no-46-Item no-8.33.1)-second floorSqm180.5180.5484.17FalseNoneNoneFalseNoneFalse87392.6850
3047537103016Nonecode83Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (vol-II-Pg.no-46-Item no-8.33.1)-terrace floorSqm182.27182.2727.0FalseNoneNoneFalseNoneFalse4921.290
3047538103016Nonecode84Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(vol-II-Pg.no-46-Item no-8.31)-First floorSqm201.35201.35202.93FalseNoneNoneFalseNoneFalse40859.95550
3047539103016Nonecode85Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(vol-II-Pg.no-46-Item no-8.31)-second floorSqm203.35203.35412.44FalseNoneNoneFalseNoneFalse83869.6740
3047540103016Nonecode86Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(vol-II-Pg.no-26-Item no-7.38)-second floorSqm648.88648.88151.0FalseNoneNoneFalseNoneFalse97980.880
3047541103016Nonecode87Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co .(vol-II-Pg.no-26-Item no-7.39.1)-second floor -Ridges plain (500 - 600mm)m515.22515.2210.5FalseNoneNoneFalseNoneFalse5409.810
3047542103016Nonecode88Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co .(vol-II-Pg.no-26-Item no-7.39.6)-second floor -Gutter(600 mm over all girth)m1226.941226.9410.0FalseNoneNoneFalseNoneFalse12269.40
3047543103016Nonecode89Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(vol-II-Pg.no-149-Item no-15.1)-second floorSqm933.34933.34466.66FalseNoneNoneFalseNoneFalse435552.44440
3047544103016Nonecode90Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.(vol-II-Pg.no-149-Item no-15.1)-Terrace floorSqm942.49942.49127.0FalseNoneNoneFalseNoneFalse119696.230
3047545103016Nonecode91Providing 12 mm cement plaster with Cement mortar 1:4 (1cement: 4 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete (vol-II-Pg.no-41-Item no-8.4.2)Sqm349.44349.44538.0FalseNoneNoneFalseNoneFalse187998.720
3047546103016Nonecode92Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. (vol-II-Pg.no-23-Item no-7.18)Cum2259.042259.0421.9FalseNoneNoneFalseNoneFalse49472.9760
3047547103016Nonecode93SANITARY FIXTURES:Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (vol-II-pg no:131-Item no:14.3.1)Each6694.246694.242.0FalseNoneNoneFalseNoneFalse13388.480
3047548103016Nonecode94Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (vol-II-pg no:131-Item no:14.1.1)Each5470.085470.085.0FalseNoneNoneFalseNoneFalse27350.40
3047549103016Nonecode95Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (vol-II-pg no:136-Item no:14.31)Each1366.41366.42.0FalseNoneNoneFalseNoneFalse2732.80
3047550103016Nonecode96Providing and fixing C.P. brass 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. (vol-II-pg no:137-Item no:14.40.2)Each555.52555.525.0FalseNoneNoneFalseNoneFalse2777.60
3047551103016Nonecode97Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (vol-II-pg no:119tem no:13.15)Each812.0812.08.0FalseNoneNoneFalseNoneFalse6496.00
3047552103016Nonecode98Providing and fixing in position chromium plated brass shower rose with 15 or 20mm inlet 150mm dia including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.16 / 13.3 (vol-II-pg no:118 tem no:13.9.1)Nos287.84287.842.0FalseNoneNoneFalseNoneFalse575.680
3047553103016Nonecode99INTERNAL & EXTERNAL SEWAGE SYSTEM :Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia., 6 kg/sqcm & class 3(vol-v-pg.no-113-Item no-10.1.6)m329.28329.2850.0FalseNoneNoneFalseNoneFalse16464.00
3047554103016Nonecode100INTERNAL & EXTERNAL SEWAGE SYSTEM :Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 50mm dia., 6 kg/sqcm & class 5(vol-v-pg.no-113-Item no-10.1.3)m113.12113.1230.0FalseNoneNoneFalseNoneFalse3393.60
3047555103016Nonecode101INTERNAL & EXTERNAL SEWAGE SYSTEM :Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 32mm dia., 10 kg/sqcm & class 5(vol-v-pg.no-113-Item no-10.1.2)m75.0475.0430.0FalseNoneNoneFalseNoneFalse2251.20
3047556103016Nonecode102INTERNAL & EXTERNAL SEWAGE SYSTEM :Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-c) PVC pipes 200mm dia., 6 kg/sqcm & class 3 -For external (vol-v-pg.no-113-Item no-10.1.10)m1248.81248.850.0FalseNoneNoneFalseNoneFalse62440.00
3047557103016Nonecode103Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments(vol-v-pg no-116-Item no-10.8.4) 50mm dia PVC couplersEach31.3631.3610.0FalseNoneNoneFalseNoneFalse313.60
3047558103016Nonecode104Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments(vol-v-pg no-116-Item no-10.8.7) 90mm dia PVC couplersEach140.0140.010.0FalseNoneNoneFalseNoneFalse1400.00
3047559103016Nonecode105Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments(vol-v-pg no-116-Item no-10.8.8)110mm dia PVC couplersEach191.52191.5210.0FalseNoneNoneFalseNoneFalse1915.20
3047560103016Nonecode106Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments(vol-v-pg no-116-Item no-10.8.10) 160mm dia PVC couplersEach375.2375.210.0FalseNoneNoneFalseNoneFalse3752.00
3047561103016Nonecode107Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.9.4) 50mm dia PVC ElbowsEach73.9273.9215.0FalseNoneNoneFalseNoneFalse1108.80
3047562103016Nonecode108Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.9.7) 90mm dia PVC ElbowsEach309.12309.128.0FalseNoneNoneFalseNoneFalse2472.960
3047563103016Nonecode109Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.9.8) 110mm dia PVC ElbowsEach338.24338.246.0FalseNoneNoneFalseNoneFalse2029.440
3047564103016Nonecode110Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.9.10) 160mm dia PVC ElbowsEach527.52527.525.0FalseNoneNoneFalseNoneFalse2637.60
3047565103016Nonecode111Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.10.4) 50mm dia PVC TeeEach68.3268.3210.0FalseNoneNoneFalseNoneFalse683.20
3047566103016Nonecode112Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.10.7) 90mm dia PVC TeeEach191.52191.525.0FalseNoneNoneFalseNoneFalse957.60
3047567103016Nonecode113Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.10.8) 110mm dia PVC TeeEach281.12281.125.0FalseNoneNoneFalseNoneFalse1405.60
3047568103016Nonecode114Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-117-Item no-10.10.10) 160mm dia PVC TeeEach521.92521.925.0FalseNoneNoneFalseNoneFalse2609.60
3047569103016Nonecode115Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-118-Item no-10.11.4-50mm dia PVC bendEach99.6899.6810.0FalseNoneNoneFalseNoneFalse996.80
3047570103016Nonecode116Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-118-Item no-10.11.7-90mm dia PVC bendEach436.8436.85.0FalseNoneNoneFalseNoneFalse2184.00
3047571103016Nonecode117Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-118-Item no-10.11.8-110mm dia PVC bendEach551.04551.042.0FalseNoneNoneFalseNoneFalse1102.080
3047572103016Nonecode118Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments (vol-v-pg no-118-Item no-10.11.8-160mm dia PVC bendEach754.88754.882.0FalseNoneNoneFalseNoneFalse1509.760
3047573103016Nonecode119WATER SUPPLY SYSTEM:Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc),(vol-II-Pgno-122-Item no-13.31.2) a) 20 mm diam271.04271.0450.0FalseNoneNoneFalseNoneFalse13552.00
3047574103016Nonecode120WATER SUPPLY SYSTEM:Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc),(vol-II-Pgno-122-Item no-13.31.3)b) 25 mm diam356.16356.1650.0FalseNoneNoneFalseNoneFalse17808.00
3047575103016Nonecode121WATER SUPPLY SYSTEM:Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc),(vol-II-Pgno-122-Item no-13.31.4) c) 32 mm diam448.0448.030.0FalseNoneNoneFalseNoneFalse13440.00
3047576103016Nonecode122WATER SUPPLY SYSTEM:Providing and fixing Chorinated Poly Venly Cloride (CPVC) pipes conforming to IS15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr. spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc),(vol-II-Pgno-122-Item no-13.31.4) d) 50 mm diam874.72874.7210.0FalseNoneNoneFalseNoneFalse8747.20
3047577103016Nonecode123Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) c) 25mm dia (Screwed ends) (vol-II-Pgno-117-Item no-13.4.1)Nos614.88614.883.0FalseNoneNoneFalseNoneFalse1844.640
3047578103016Nonecode124Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) d) 32mm dia (Screwed ends) (vol-II-Pgno-117-Item no-13.4.2)Nos669.76669.761.0FalseNoneNoneFalseNoneFalse669.760
3047579103016Nonecode125Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) f) 50mm dia (Screwed ends) (vol-II-Pgno-117-Item no-13.4.4)Nos957.6957.62.0FalseNoneNoneFalseNoneFalse1915.20
3047580103016Nonecode126Solar hot water heater-Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. Fitted with Sacrificial Anode (vol-vi-Pgno-35-Item no-7.4.3)-7.4.3)300 L- 29 nos TubesEach51528.051528.04.0FalseNoneNoneFalseNoneFalse206112.00
3047581103016Nonecode127PART-A INTERNAL WIRING-Point wiring using Copper wire without Switch.Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.(vol-VI-pg.no-05) 2.2.1)Short point upto 3Mtr from tapping point to out let via switch boxNos269.0269.015.0FalseNoneNoneFalseNoneFalse4035.00
3047582103016Nonecode128Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (vol-VI-pg.no-05) 2.2.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch boxNos379.0379.06.0FalseNoneNoneFalseNoneFalse2274.00
3047583103016Nonecode129Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (vol-VI-pg.no-05) 2.2.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch boxNos555.0555.015.0FalseNoneNoneFalseNoneFalse8325.00
3047584103016Nonecode130Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (vol-VI-pg.no-05) 2.2.4)Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switchesNos677.0677.012.0FalseNoneNoneFalseNoneFalse8124.00
3047585103016Nonecode131Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. (vol-VI-pg.no-05) 2.2.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches boxNos989.0989.015.0FalseNoneNoneFalseNoneFalse14835.00
3047586103016Nonecode132Metal Boxes:Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-Vol-vi-pg.no-8-3.4.1) 1-3WayEach138.0138.070.0FalseNoneNoneFalseNoneFalse9660.00
3047587103016Nonecode133Metal Boxes:Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-Vol-vi-pg.no-8-3.4.3)4-5WayEach177.0177.015.0FalseNoneNoneFalseNoneFalse2655.00
3047588103016Nonecode134Metal Boxes:Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-Vol-vi-pg.no-8-3.4.4)6 WayEach220.0220.07.0FalseNoneNoneFalseNoneFalse1540.00
3047589103016Nonecode135Metal Boxes:Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-Vol-vi-pg.no-8-3.4.5)8WayEach261.0261.025.0FalseNoneNoneFalseNoneFalse6525.00
3047590103016Nonecode136Metal Boxes:Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall-Vol-vi-pg.no-8-3.4.6) 10-12WayEach319.0319.010.0FalseNoneNoneFalseNoneFalse3190.00
3047591103016Nonecode137Suppling and fixing PVC/metal conduit deep juction boxes-1.5.1)19/20mm deep juction boxEach49.049.065.0FalseNoneNoneFalseNoneFalse3185.00
3047592103016Nonecode138Suppling and fixing PVC/metal conduit deep juction boxes-1.5.2) 25mm deep juction boxEach56.056.060.0FalseNoneNoneFalseNoneFalse3360.00
3047593103016Nonecode139Suppling and fixing PVC/metal conduit deep juction boxes-1.5.3) 32mm deep juction boxEach61.061.010.0FalseNoneNoneFalseNoneFalse610.00
3047594103016Nonecode140Suppling and fixing PVC/metal conduit deep juction boxes-1.13)Suplay and fixing Metal Fan Box with Round HookEach117.0117.015.0FalseNoneNoneFalseNoneFalse1755.00
3047595103016Nonecode141Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on exisinting gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as requiredEach170.0170.03.0FalseNoneNoneFalseNoneFalse510.00
3047596103016Nonecode142Switch mounting polycorbonate plate-Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. Vol-vi-pg.no-8 3.5.1) 1 to 2ModuleEach137.0137.075.0FalseNoneNoneFalseNoneFalse10275.00
3047597103016Nonecode143Switch mounting polycorbonate plate-Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. Vol-vi-pg.no-8 3.5.2) 4 ModuleEach175.0175.015.0FalseNoneNoneFalseNoneFalse2625.00
3047598103016Nonecode144Switch mounting polycorbonate plate-Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. Vol-vi-pg.no-8 3.5.3) 6 ModuleEach234.0234.07.0FalseNoneNoneFalseNoneFalse1638.00
3047599103016Nonecode145Switch mounting polycorbonate plate-Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. Vol-vi-pg.no-8 3.5.4) 8 ModuleEach284.0284.025.0FalseNoneNoneFalseNoneFalse7100.00
3047600103016Nonecode146Switch mounting polycorbonate plate-Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. Vol-vi-pg.no-8 3.5.5) 10-12 ModuleEach344.0344.010.0FalseNoneNoneFalseNoneFalse3440.00
3047601103016Nonecode147Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.1) 6A mps one wayEach102.0102.0175.0FalseNoneNoneFalseNoneFalse17850.00
3047602103016Nonecode148Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.2) 6A mps Two wayEach166.0166.04.0FalseNoneNoneFalseNoneFalse664.00
3047603103016Nonecode149Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.3) 6A mps 3way socket.Each171.0171.061.0FalseNoneNoneFalseNoneFalse10431.00
3047604103016Nonecode150Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.4) Stepped fan regulator.Each357.0357.015.0FalseNoneNoneFalseNoneFalse5355.00
3047605103016Nonecode151Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.7) 16Amps one way switchEach180.0180.08.0FalseNoneNoneFalseNoneFalse1440.00
3047606103016Nonecode152Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.10) 6/16Amps univeral socketEach236.0236.08.0FalseNoneNoneFalseNoneFalse1888.00
3047607103016Nonecode153Modular switch/Socket-Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. Using Group 'A' materials-3.6.11) TV/Telephone socketEach156.0156.04.0FalseNoneNoneFalseNoneFalse624.00
3047608103016Nonecode154Supplyingandfixing32AsecurityandenergysavingDPswitchwithkeytagsuitabletooperateon230V,50HzACsupply&completely wired on existing box. 3.7) 32Amps flush/projected type DP switchEach646.0646.09.0FalseNoneNoneFalseNoneFalse5814.00
3047609103016Nonecode155Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 1.2.1) 19/20mm dia 2mm thickm66.066.01300.0FalseNoneNoneFalseNoneFalse85800.00
3047610103016Nonecode156Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 1.2.2) 25mm dia 2mm thickm78.078.01300.0FalseNoneNoneFalseNoneFalse101400.00
3047611103016Nonecode157Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary 1.2.3) 32mm dia 2.5mm thickm103.0103.0290.0FalseNoneNoneFalseNoneFalse29870.00
3047612103016Nonecode158Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. I Group A Materials.1.3.1) 19/20mm dia 2mm thikm68.068.0400.0FalseNoneNoneFalseNoneFalse27200.00
3047613103016Nonecode159Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. I Group A Materials.1.3.2) 25mm dia 2mm thikm79.079.0375.0FalseNoneNoneFalseNoneFalse29625.00
3047614103016Nonecode160Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. I Group A Materials.1.3.3) 32mm dia 2.5mm thikm99.099.0100.0FalseNoneNoneFalseNoneFalse9900.00
3047615103016Nonecode161Wiring for lighting /power circuit wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010 I Group A Materials.2.3.2) 1.5 sqmmm26.026.0850.0FalseNoneNoneFalseNoneFalse22100.00
3047616103016Nonecode162Wiring for lighting /power circuit wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010 I Group A Materials.2.3.3) 2.5 sqmmm42.042.01600.0FalseNoneNoneFalseNoneFalse67200.00
3047617103016Nonecode163Wiring for lighting /power circuit wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010 I Group A Materials.2.3.4) 4 sqmmm63.063.0350.0FalseNoneNoneFalseNoneFalse22050.00
3047618103016Nonecode164Wiring for lighting /power circuit wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010 I Group A Materials.2.3.3) 6 sqmmm92.092.0480.0FalseNoneNoneFalseNoneFalse44160.00
3047619103016Nonecode165MCB & DBs Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete II. Double Door -8Way SP & N-Item no-5.19.8Each1854.01854.01.0FalseNoneNoneFalseNoneFalse1854.00
3047620103016Nonecode166MCB & DBs Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete III. Double Door -6Way TP & N-Item no-5.19.12Each4940.04940.01.0FalseNoneNoneFalseNoneFalse4940.00
3047621103016Nonecode167Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board. 5.20.4)32-40 Amps 2 PoleEach4559.04559.03.0FalseNoneNoneFalseNoneFalse13677.00
3047622103016Nonecode168Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board. 5.20.8)32-40 Amps 4 PoleEach5147.05147.03.0FalseNoneNoneFalseNoneFalse15441.00
3047623103016Nonecode169Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C'Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.5.18.1)6-32Amps SPEach415.0415.024.0FalseNoneNoneFalseNoneFalse9960.00
3047624103016Nonecode170Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C'Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.5.18.4)6-32Amps DPEach739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
3047625103016Nonecode171Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C'Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.5.18.5)40Amps DPEach1060.01060.02.0FalseNoneNoneFalseNoneFalse2120.00
3047626103016Nonecode172Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C'Type curve, indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898.5.18.9)50-63Amps TPNEach3088.03088.02.0FalseNoneNoneFalseNoneFalse6176.00
3047627103016Nonecode173PART -B-1 LIGHT FIXTURES :Supplying of 2 feet LED PVC square batten with high quality diffuser with ife of 25000 burninng hours & 70% lumen maintance with CRI80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 5 years warranty-11.3.1)LED light fitting 1x2' -9/10wEach551.0551.06.0FalseNoneNoneFalseNoneFalse3306.00
3047628103016Nonecode174PART -B-1 LIGHT FIXTURES :Supplying of 2 feet LED PVC square batten with high quality diffuser with ife of 25000 burninng hours & 70% lumen maintance with CRI80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 5 years warranty-11.3.2)LED light fitting 1x4' -20/22wEach690.0690.050.0FalseNoneNoneFalseNoneFalse34500.00
3047629103016Nonecode175Supplying of recess/Surface mounting non integrated type LED down light ...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.11.5.2) 10-12WEach885.0885.021.0FalseNoneNoneFalseNoneFalse18585.00
3047630103016Nonecode176Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, deliveringsuperior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 90 W-vol-vi-pg.no-46-11.8.4Nos8860.08860.04.0FalseNoneNoneFalseNoneFalse35440.00
3047631103016Nonecode177Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply..vol-vi-pg.no-30-6.1Each1492.01492.05.0FalseNoneNoneFalseNoneFalse7460.00
3047632103016Nonecode178Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double bail bearing system.48" Sweep (1200mm) 6.3.1)Regular modelEach2984.02984.012.0FalseNoneNoneFalseNoneFalse35808.00
3047633103016Nonecode179Labour Portion Fixing all types and all capacities of fluorescent / fales ceiling /spot light /CFL / LED fittings indoor on the wall /ceiling / refters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps . On wall / ceiling / Rafter / Girders -vol-vi-56-13.7.1Each122.0122.077.0FalseNoneNoneFalseNoneFalse9394.00
3047634103016Nonecode180Fixing a ceiling / wall mounting fan of all capacities and all types to the existing 's' hook with fan regulator to the existing board together with supplying and fixiting 5amps . Ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring . vol-vi-57-13.10Each171.0171.017.0FalseNoneNoneFalseNoneFalse2907.00
3047635103016Nonecode181Internal road -Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.(Vol-III-pgno-09-Item no-2.4.i a)-In area of light jungle( rate for 100 sqm) and qty also convertedSqm1256.641256.641.2FalseNoneNoneFalseNoneFalse1507.9680
3047636103016Nonecode182Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work (Vol-III-pgno-17-Item no-301)Cum95.295.248.6FalseNoneNoneFalseNoneFalse4626.720
3047637103016Nonecode183Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.(vol-i-pg no-07-item no-1.8)Cum530.88530.8824.3FalseNoneNoneFalseNoneFalse12900.3840
3047638103016Nonecode184Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. (Vol-III-pgno-17-Item no-305.3.4)Cum117.6117.616.2FalseNoneNoneFalseNoneFalse1905.120
3047639103016Nonecode185Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2 (Vol-III-pgno-17-Item no-305)Cum552.16552.1613.5FalseNoneNoneFalseNoneFalse7454.160
3047640103016Nonecode186Construction of Dry lean cement concrete sub-base over a prepared sub grade with coarse and fine aggregates confirming to IS 383:2016 the size of coarse aggregates not exceeding 25mm replacing cement by fly ash to the extent of 20 percent, aggregate cement ratio not to exceed 12:1 aggregates gradation after blending to be as per table 600-1, cement & cementitious content not to be less than 140 kg/m3, optimum moisture content to beg.determined during trial length construction , concrete strength not to be less than 7 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 t vibratory roller, finishing and curing.(vol-III-pg no-49-Item no-6.3)Cum5303.25303.26.75FalseNoneNoneFalseNoneFalse35796.60
3047641103016Nonecode187Construction of M40 grade un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with Cement at 420 kg/m3, coarse and fine aggregate conforming to IS 383:2016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design transported to site, laid with a paver finisher, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing (vol-III-pg no-49-Item no-6.2.1)Cum10148.3210148.3210.13FalseNoneNoneFalseNoneFalse102802.48160
3047642103016Nonecode188Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(vol-I-pg no-18-Item no-2.11h)Tonne88492.3288492.320.08FalseNoneNoneFalseNoneFalse7079.38560
3047643103016Nonecode189Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:4:8 (M7.5) Using 40 mm and down size graded crushed coarse aggregates (vol-I-pg no-15-Item no-2.1.2)Cum6343.686343.6810.55FalseNoneNoneFalseNoneFalse66925.8240
3047644103016Nonecode190Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) (vol-III-pg no-74-Item no-8.42.2)-600 x 600x 100 mm sizem280.0280.040.0FalseNoneNoneFalseNoneFalse11200.00
3047645103016Nonecode191Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (vol-II-pg no-63-Item no-9.25)Sqm896.0896.075.0FalseNoneNoneFalseNoneFalse67200.00
3047646103016Nonecode192Culvert-Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. (vol-I-pg no-10-Item no-1.17.1) Considering 100% of the qnty for ordinary soilCum293.44293.4414.83FalseNoneNoneFalseNoneFalse4351.71520
3047647103016Nonecode193Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates (vol-I-pg no-15-Item no-2.1.3)Cum6707.686707.681.06FalseNoneNoneFalseNoneFalse7110.14080
3047648103016Nonecode194Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)Cum7789.947789.944.74FalseNoneNoneFalseNoneFalse36924.31560
3047649103016Nonecode195Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(vol-I-pg no-18-Item no-2.11 h)Tonne88492.3288492.320.7FalseNoneNoneFalseNoneFalse61944.6240
3047650103016Nonecode196Culvert- Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. (vol-I-pg no-10-Item no-1.17.1) Considering 100% of the qnty for ordinary soilCum293.44293.4414.83FalseNoneNoneFalseNoneFalse4351.71520
3047651103016Nonecode197Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates (vol-I-pg no-15-Item no-2.1.3)Cum6707.686707.681.06FalseNoneNoneFalseNoneFalse7110.14080
3047652103016Nonecode198Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included)Cum7789.947789.944.74FalseNoneNoneFalseNoneFalse36924.31560
3047653103016Nonecode199Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(vol-I-pg no-18-Item no-2.11 h)Tonne88492.3288492.320.7FalseNoneNoneFalseNoneFalse61944.6240
3047654103016Nonecode200DIESEL GENERATOR SET-'Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications.Use of special hardware for longer life, Insulation materialmeets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.30 kVA/24kW-Vol-VI-pgno-42-10.1.4Set457067.0457067.01.0FalseNoneNoneFalseNoneFalse457067.00
3047655103016Nonecode201Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.30 kVA/24kW-Vol-VI-pgno-42-10.2.1Each58711.058711.01.0FalseNoneNoneFalseNoneFalse58711.00
3047656103016Nonecode202Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (vol-II-pg no-17-Item no-6.32) -dg-platformSqm1310.01310.08.1FalseNoneNoneFalseNoneFalse10611.00
3047657103016Nonecode203Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(vol-II-pg no-23-Item no-7.18)Sqm2017.02017.09.0FalseNoneNoneFalseNoneFalse18153.00
3047658103016Nonecode204Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External (vol-II-pg no-42-Item no-8.8)Sqm371.0371.028.1FalseNoneNoneFalseNoneFalse10425.10
3047659103016Nonecode205Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.all-roundm61.8661.8665.0FalseNoneNoneFalseNoneFalse4020.90
3047660103016Nonecode206Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.all-round outer wall horizontalm26.2726.27260.0FalseNoneNoneFalseNoneFalse6830.20
3047661103016Nonecode207Providing and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter.Nos3951.693951.6910.0FalseNoneNoneFalseNoneFalse39516.90
3047662103016Nonecode208Providing, fixing, testing and commissioning of deep seal PVC multi inlet floor trap of self cleansing design moulded or fabricated with CP grating, rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste including making good the floors etc., complete as directed by the Engineer in charge & approved quality confirming to ISI or BIS StandardsEach266.95266.955.0FalseNoneNoneFalseNoneFalse1334.750
3047663103016Nonecode209Supplying, installing and testing 2WAY BIB COCK (Ritco flora or equivalent) & 15 mm CP health faucet (Hindware F160027 or equivalent) of approved make with necessary CP flexible hose 1200mm long nozzle, CP wall flange etc., including cost of materials,labour complte as per specification complete.Nos1307.631307.6312.0FalseNoneNoneFalseNoneFalse15691.560
3047664103016Nonecode210Providing and fixing in position brass push cock of approved quality 15mm nominal bore including cost of all materials, CP wall flange etc., including cost of materials,labour complte as per specification complete.Supplying & InstallationNos720.34720.3422.0FalseNoneNoneFalseNoneFalse15847.480
3047665103016Nonecode211Supplying, fixing, testing and commissioning of two - in - one wall mixer shower assembly unit consisting of the following in the shower area: Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. Single Lever Wall Mixer with provision of Hand Shower, but without Hand Shower SKU: ARI-CHR-39119 (jaquar or equilent Make)Nos6947.466947.464.0FalseNoneNoneFalseNoneFalse27789.840
3047666103016Nonecode212CAMERAS & ACCESSORIES: Supply, erection, testing & commissioning 2 Megapixel high-performance CMOS, Analog HD output, up to 1080P resolution, True Day/Night, True WDR, up to 120dB,EXIR technology, up to 20m IR distance , IP66 weatherproof ,Max. 5W, with 4*4 Model Box for Camera and other accessories.Nos4676.274676.276.0FalseNoneNoneFalseNoneFalse28057.620
3047667103016Nonecode213Supply, erection, testing & commissioning of 12/24V, 4 out put Camera Power Supply (SMPS, switched-mode power supply) Each Camera have Separate Terminal, including all Accessories.Nos1298.311298.316.0FalseNoneNoneFalseNoneFalse7789.860
3047668103016Nonecode214Providing and fixing in position precast ferrocement slab of 20mm thick and 600mm wide for storage rack suitable for storage of office files with required length including finishing, painting , labour charges, transportation, materials charges any taxes applicable etc,. complete as directed by the Engineer incharge of the work.concrete mix proportion: Equivalent to M25 Strength, mild steel flats of size 20x3 mm diameter are to be used for main and distribution reinforcement.Chicken mesh is to be provided in two layer for secondary reinforcement.Sqm2796.612796.61140.0FalseNoneNoneFalseNoneFalse391525.40
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17103323690000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17103323690000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17103323690000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17103323710000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17103323750000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17103323800000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17103323830000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17103323870000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17103323900000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17103323940000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17103323970000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17103324000000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17103324040000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17103324070000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17103324110000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17103324140000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17103324200000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17103324250000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1710337394000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone