1710331240000 | 0 | None | None | Buildings | Construction of Post Metric Girls Hostel 2nd Phase at Kundapura, Udupi District | 13087725.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3044869 | 102911 | None | code01 | Plain Cement Concrete : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 -Page No- 15, It No - 2.1.4) (Second Floor) (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 7102.3 | 7102.3 | 0.89 | False | None | None | False | None | False | 6321.047 | 0 | 3044870 | 102911 | None | code02 | Plain Cement Concrete : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 -Page No- 15, It No - 2.1.4) (Third Floor) (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 7171.93 | 7171.93 | 1.43 | False | None | None | False | None | False | 10255.8599 | 0 | 3044871 | 102911 | None | code03 | Plain Cement Concrete : Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 -Page No- 15, It No - 2.1.4) (Terrace Floor) (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 7241.56 | 7241.56 | 16.13 | False | None | None | False | None | False | 116806.3628 | 0 | 3044872 | 102911 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 -Page No- 16, It No 2.5.2), Second floor-(The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 14055.76 | 14055.76 | 8.26 | False | None | None | False | None | False | 116100.5776 | 0 | 3044873 | 102911 | None | code05 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 -Page No- 16, It No 2.5.2) Third floor (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 14193.56 | 14193.56 | 19.44 | False | None | None | False | None | False | 275922.8064 | 0 | 3044874 | 102911 | None | code06 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 -Page No- 16, It No 2.5.2) Terrace floor (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 14442.96 | 14442.96 | 3.22 | False | None | None | False | None | False | 46506.3312 | 0 | 3044875 | 102911 | None | code07 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 -Page No- 16, It No 2.5.2) Second Floor Roof Beam (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 13164.57 | 13164.57 | 12.24 | False | None | None | False | None | False | 161134.3368 | 0 | 3044876 | 102911 | None | code08 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 -Page No- 16, It No 2.5.2)Third Floor Roof Beam (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 13293.64 | 13293.64 | 24.32 | False | None | None | False | None | False | 323301.3248 | 0 | 3044877 | 102911 | None | code09 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(Vol -1 -Page No- 16, It No 2.5.2) Second Floor Roof Slab (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 12273.39 | 12273.39 | 18.56 | False | None | None | False | None | False | 227794.1184 | 0 | 3044878 | 102911 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specificati(Vol -1 -Page No- 16, It No 2.5.2)Third Floor Roof Slab (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 12393.71 | 12393.71 | 30.3 | False | None | None | False | None | False | 375529.413 | 0 | 3044879 | 102911 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Drain top cover slab, (Vol -1 -Page No- 16, It No 2.5.2) (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 10346.62 | 10346.62 | 1.66 | False | None | None | False | None | False | 17175.3892 | 0 | 3044880 | 102911 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Head Room slab, (Vol -1 -Page No- 16, It No 2.5.2) (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 12593.75 | 12593.75 | 6.0 | False | None | None | False | None | False | 75562.5 | 0 | 3044881 | 102911 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, (Vol -1 -Page No- 16, It No 2.5.2), Second Floor Lintel, (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 13164.57 | 13164.57 | 2.78 | False | None | None | False | None | False | 36597.5046 | 0 | 3044882 | 102911 | None | code14 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, (Vol -1 -Page No- 16, It No 2.5.2),Third Floor Lintel,- (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 13293.64 | 13293.64 | 4.43 | False | None | None | False | None | False | 58890.8252 | 0 | 3044883 | 102911 | None | code15 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to therequirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, (Vol -1 -Page No- 16, It No 2.5.2)Third Third floor Stair case (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 12393.71 | 12393.71 | 4.23 | False | None | None | False | None | False | 52425.3933 | 0 | 3044884 | 102911 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol -1 Page No- 16, It No-2.5.1) Second floor-Chajja. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 11459.63 | 11459.63 | 4.82 | False | None | None | False | None | False | 55235.4166 | 0 | 3044885 | 102911 | None | code17 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarseaggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. , (Vol -1 Page No- 16, It No-2.5.1),Third floor-Chajja. (The cost of steel reinforcement shall be paid separately and the formwork &shuttering rates are included) | Cum | 11571.98 | 11571.98 | 3.72 | False | None | None | False | None | False | 43047.7656 | 0 | 3044886 | 102911 | None | code18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. , (Vol-I- Page No - 18, It No.2.11(a) Second floor | Tonne | 102195.68 | 102195.68 | 6.88 | False | None | None | False | None | False | 703106.2784 | 0 | 3044887 | 102911 | None | code19 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. , (Vol-I- Page No - 18, It No.2.11(a). Third floor | Tonne | 103197.6 | 103197.6 | 14.06 | False | None | None | False | None | False | 1450958.256 | 0 | 3044888 | 102911 | None | code20 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Vol-I- Page No - 18, It No.2.11(a) . Terrace floor | Tonne | 104199.51 | 104199.51 | 1.24 | False | None | None | False | None | False | 129207.3924 | 0 | 3044889 | 102911 | None | code21 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6., (Vol- II- Page No-09, It no 5.7) Second floor | Cum | 7716.91 | 7716.91 | 39.43 | False | None | None | False | None | False | 304277.7613 | 0 | 3044890 | 102911 | None | code22 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6., (Vol- II- Page No-09, It no 5.7), Third floor | Cum | 7792.57 | 7792.57 | 60.9 | False | None | None | False | None | False | 474567.513 | 0 | 3044891 | 102911 | None | code23 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6., (Vol- II- Page No-09, It no 5.7), Third floor Parapet wall | Cum | 7792.57 | 7792.57 | 4.13 | False | None | None | False | None | False | 32183.3141 | 0 | 3044892 | 102911 | None | code24 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Super structure in CM 1:6. (Vol- II- Page No-09, It no 5.7), Terrace Floor | Cum | 7868.22 | 7868.22 | 6.6 | False | None | None | False | None | False | 51930.252 | 0 | 3044893 | 102911 | None | code25 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol- II- Page No-17, It no 6.34) Second Floor | Sqm | 1261.21 | 1261.21 | 67.74 | False | None | None | False | None | False | 85434.3654 | 0 | 3044894 | 102911 | None | code26 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Vol- II- Page No-17, It no 6.34) Third Floor | Sqm | 1273.57 | 1273.57 | 64.4 | False | None | None | False | None | False | 82017.908 | 0 | 3044895 | 102911 | None | code27 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Inside walls), (Vol- II- Page No-42, It no 8.7) Second Floor | Sqm | 418.12 | 418.12 | 475.77 | False | None | None | False | None | False | 198928.9524 | 0 | 3044896 | 102911 | None | code28 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Inside walls), (Vol- II- Page No-42, It no 8.7), Third Floor, | Sqm | 422.22 | 422.22 | 495.48 | False | None | None | False | None | False | 209201.5656 | 0 | 3044897 | 102911 | None | code29 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External, (Vol- II- Page No-42, It no 8.8), Second Floor | Sqm | 423.83 | 423.83 | 578.26 | False | None | None | False | None | False | 245083.9358 | 0 | 3044898 | 102911 | None | code30 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External, (Vol- II- Page No-42, It no 8.8) Third Floor | Sqm | 427.99 | 427.99 | 347.6602 | False | None | None | False | None | False | 148795.088998 | 0 | 3044899 | 102911 | None | code31 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External,(Vol- II- Page No-42, It no 8.8), Terrace Floor | Sqm | 432.14 | 432.14 | 105.6 | False | None | None | False | None | False | 45633.984 | 0 | 3044900 | 102911 | None | code32 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Inside rough Plastering) (Vol- II- Page No-42, It no 8.7) Second Floor | Sqm | 418.12 | 418.12 | 165.27 | False | None | None | False | None | False | 69102.6924 | 0 | 3044901 | 102911 | None | code33 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(Inside rough Plastering) (Vol- II- Page No-42, It no 8.7) Third Floor | Sqm | 422.22 | 422.22 | 135.48 | False | None | None | False | None | False | 57202.3656 | 0 | 3044902 | 102911 | None | code34 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling). (Vol- II- Page No-42, It no 8.6.1) Second Floor | Sqm | 369.0 | 369.0 | 121.2 | False | None | None | False | None | False | 44722.8 | 0 | 3044903 | 102911 | None | code35 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling). v (Vol- II- Page No-42, It no 8.6.1) Third Floor | Sqm | 372.61 | 372.61 | 235.35 | False | None | None | False | None | False | 87693.7635 | 0 | 3044904 | 102911 | None | code36 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Ceiling). (Vol- II- Page No-42, It no 8.6.1) Terrace floor-Headroom | Sqm | 376.23 | 376.23 | 42.0 | False | None | None | False | None | False | 15801.66 | 0 | 3044905 | 102911 | None | code37 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment Plaster mesh 150mm wide. (Vol- II- Page No-42, It no 8.16.2) | Sqm | 42.56 | 42.56 | 1035.2 | False | None | None | False | None | False | 44058.112 | 0 | 3044906 | 102911 | None | code38 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(75x125mm), (Vol- II- Page No-100, It no 12.13.2), Second floor | Cum | 113783.04 | 113783.04 | 0.31 | False | None | None | False | None | False | 35272.7424 | 0 | 3044907 | 102911 | None | code39 | Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(75x125mm),(Vol- II- Page No-100, It no 12.13.2)Third Floor | Cum | 114898.56 | 114898.56 | 0.95 | False | None | None | False | None | False | 109153.632 | 0 | 3044908 | 102911 | None | code40 | Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. (Vol- II- Page No-104, It no 12.51), All floors | Nos | 1160.68 | 1160.68 | 22.0 | False | None | None | False | None | False | 25534.96 | 0 | 3044909 | 102911 | None | code41 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial, (Vol- II- Page No-105, It no 12.57.6), Second floor | Sqm | 3795.05 | 3795.05 | 9.6 | False | None | None | False | None | False | 36432.48 | 0 | 3044910 | 102911 | None | code42 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick both side commercial, (Vol- II- Page No-105, It no 12.57.6)Third floor | Sqm | 3832.26 | 3832.26 | 12.48 | False | None | None | False | None | False | 47826.6048 | 0 | 3044911 | 102911 | None | code43 | Providing and fixing flush door shutter made out of solid core black board type, well seasoned chemically treated hard wood battens and internal frame with minimum 45 mm wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as per specification. - 30mm thick both side commercial and laminated ., (Vol- II- Page No-106, It no 12.57.3) | Sqm | 3466.57 | 3466.57 | 21.84 | False | None | None | False | None | False | 75709.8888 | 0 | 3044912 | 102911 | None | code44 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. (Vol- II- Page No-107, It no 12.62) All Floors | Nos | 265.44 | 265.44 | 26.0 | False | None | None | False | None | False | 6901.44 | 0 | 3044913 | 102911 | None | code45 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete(Only for toilet doors),(Vol- II- Page No-107, It no 12.63) | Nos | 145.6 | 145.6 | 13.0 | False | None | None | False | None | False | 1892.8 | 0 | 3044914 | 102911 | None | code46 | Providing and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws etc.-125x65x2.12mm.(For toilet doors) (Vol- II- Page No-107, It no 12.68) | Nos | 61.6 | 61.6 | 39.0 | False | None | None | False | None | False | 2402.4 | 0 | 3044915 | 102911 | None | code47 | Providing and fixing MS Hold fasts (For all the doors) vol -II- A-25, It No. 444 | Nos | 56.0 | 56.0 | 88.0 | False | None | None | False | None | False | 4928.0 | 0 | 3044916 | 102911 | None | code48 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plainfloat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(Vol- II- Page No-110, It no 12.89) Second floor | Sqm | 7483.86 | 7483.86 | 18.12 | False | None | None | False | None | False | 135607.5432 | 0 | 3044917 | 102911 | None | code49 | Providing & fixing of 2.5 track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 94mm width x 45mm height with reinforcement of 1mm thickness and Sash with overall size of 39mm x 58mm with GI reinforcement of 1.5mm and mesh sash of size 25mm x 42mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plainfloat glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 1819mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made))(Vol- II- Page No-110, It no 12.89) Third floor | Sqm | 7557.23 | 7557.23 | 23.34 | False | None | None | False | None | False | 176385.7482 | 0 | 3044918 | 102911 | None | code50 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4 mm thickness (weight not less than 10 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. )(Vol- II- Page No-88, It no 11.37.1) , Second Floor | Sqm | 1128.69 | 1128.69 | 6.12 | False | None | None | False | None | False | 6907.5828 | 0 | 3044919 | 102911 | None | code51 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4 mm thickness (weight not less than 10 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications. )(Vol- II- Page No-88, It no 11.37.1) , Third Floor | Sqm | 1139.76 | 1139.76 | 11.43 | False | None | None | False | None | False | 13027.4568 | 0 | 3044920 | 102911 | None | code52 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.)(Vol- II- Page No-86, It no 11.34A) , Second floor | Kg | 191.92 | 191.92 | 729.04 | False | None | None | False | None | False | 139917.3568 | 0 | 3044921 | 102911 | None | code53 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.(Vol- II- Page No-86, It no 11.34A), Third floor | Kg | 193.8 | 193.8 | 840.17 | False | None | None | False | None | False | 162824.946 | 0 | 3044922 | 102911 | None | code54 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.. (Vol- II- Page No-75, It no 11.5.2), Third Floor | Sqm | 4893.57 | 4893.57 | 3.15 | False | None | None | False | None | False | 15414.7455 | 0 | 3044923 | 102911 | None | code55 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Vol -II- Page No 85, It No.11.28) Third floor | Kg | 651.78 | 651.78 | 74.7 | False | None | None | False | None | False | 48687.966 | 0 | 3044924 | 102911 | None | code56 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (Vol -II- Page No.61, It No.9.17.2)Second Floor | Sqm | 1342.32 | 1342.32 | 97.92 | False | None | None | False | None | False | 131439.9744 | 0 | 3044925 | 102911 | None | code57 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. (Vol -II- Page No.61, It No.9.17.2)Third Floor | Sqm | 1355.48 | 1355.48 | 104.08 | False | None | None | False | None | False | 141078.3584 | 0 | 3044926 | 102911 | None | code58 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (Vol -II- Page No.63, It No9.24) Second Floor | Sqm | 3258.12 | 3258.12 | 31.63 | False | None | None | False | None | False | 103054.3356 | 0 | 3044927 | 102911 | None | code59 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. (Vol -II- Page No.63, It No9.24) Second Floor | Sqm | 3290.07 | 3290.07 | 65.42 | False | None | None | False | None | False | 215236.3794 | 0 | 3044928 | 102911 | None | code60 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (Vol -II- Page No- 60, It No.9.11) Second floor | Sqm | 1015.59 | 1015.59 | 30.0 | False | None | None | False | None | False | 30467.7 | 0 | 3044929 | 102911 | None | code61 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (Vol -II- Page No- 60, It No.9.11) Third floor | Sqm | 1025.55 | 1025.55 | 48.0 | False | None | None | False | None | False | 49226.4 | 0 | 3044930 | 102911 | None | code62 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Vol -II- Page No-65, It No 9.39) Second floor same as rough plastering qty | Sqm | 1655.34 | 1655.34 | 165.27 | False | None | None | False | None | False | 273578.0418 | 0 | 3044931 | 102911 | None | code63 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (Vol -II- Page No-65, It No 9.39) Third floor same as rough plastering qty | Sqm | 1671.57 | 1671.57 | 135.48 | False | None | None | False | None | False | 226464.3036 | 0 | 3044932 | 102911 | None | code64 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No 48, It No 8.41) Second floor Grill quantity | Sqm | 187.82 | 187.82 | 34.72 | False | None | None | False | None | False | 6521.1104 | 0 | 3044933 | 102911 | None | code65 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No 48, It No 8.41) Third floor Grill Quantity | Sqm | 187.86 | 187.86 | 36.53 | False | None | None | False | None | False | 6862.5258 | 0 | 3044934 | 102911 | None | code66 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Vol -II- Page No-50, It No.8.51) Second Floor | Sqm | 114.24 | 114.24 | 596.97 | False | None | None | False | None | False | 68197.8528 | 0 | 3044935 | 102911 | None | code67 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Vol -II- Page No-50, It No.8.51) Third Floor | Sqm | 115.36 | 115.36 | 730.83 | False | None | None | False | None | False | 84308.5488 | 0 | 3044936 | 102911 | None | code68 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Vol -II- Page No-50, It No.8.51) Terrace Floor | Sqm | 116.48 | 116.48 | 42.0 | False | None | None | False | None | False | 4892.16 | 0 | 3044937 | 102911 | None | code69 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No-46, It No.8.33.1) Ceiling and Internal Wall Quantity SF | Sqm | 180.5 | 180.5 | 596.97 | False | None | None | False | None | False | 107753.085 | 0 | 3044938 | 102911 | None | code70 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No-46, It No.8.33.1) Ceiling and Internal Wall Quantity TF | Sqm | 182.27 | 182.27 | 730.83 | False | None | None | False | None | False | 133208.3841 | 0 | 3044939 | 102911 | None | code71 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No-46, It No.8.33.1) Ceiling and Internal Wall Quantity TF | Sqm | 184.04 | 184.04 | 42.0 | False | None | None | False | None | False | 7729.68 | 0 | 3044940 | 102911 | None | code72 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No 46, It No-8.31) SF Same As External Plastering Quantity-100% | Sqm | 203.35 | 203.35 | 578.26 | False | None | None | False | None | False | 117589.171 | 0 | 3044941 | 102911 | None | code73 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No 46, It No-8.31) TF Same As External Plastering Quantity-100% | Sqm | 205.34 | 205.34 | 347.16 | False | None | None | False | None | False | 71285.8344 | 0 | 3044942 | 102911 | None | code74 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Vol -II- Page No 46, It No-8.31) Terrace floor | Sqm | 207.33 | 207.33 | 105.6 | False | None | None | False | None | False | 21894.048 | 0 | 3044943 | 102911 | None | code75 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Vol II- Page No-26, It No-7.38) Third floor | Sqm | 638.2 | 638.2 | 161.28 | False | None | None | False | None | False | 102928.896 | 0 | 3044944 | 102911 | None | code76 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co (Vol II-Page No-27, It No.7.39.1) Ridges plain (500 - 600mm) | m | 506.74 | 506.74 | 14.0 | False | None | None | False | None | False | 7094.36 | 0 | 3044945 | 102911 | None | code77 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top co (Vol II-Page No-27, It No.7.39.6)Gutter (600 mm over all girth) | m | 1206.75 | 1206.75 | 36.0 | False | None | None | False | None | False | 43443.0 | 0 | 3044946 | 102911 | None | code78 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Vol -II- Page No-149, It No-15.1) Second floor | Sqm | 933.34 | 933.34 | 36.6 | False | None | None | False | None | False | 34160.244 | 0 | 3044947 | 102911 | None | code79 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Vol -II- Page No-149, It No-15.1) Third floor | Sqm | 942.49 | 942.49 | 64.8 | False | None | None | False | None | False | 61073.352 | 0 | 3044948 | 102911 | None | code80 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/ Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (Vol -II- Page No-149, It No-15.1) Terrace floor | Sqm | 951.64 | 951.64 | 232.7 | False | None | None | False | None | False | 221446.628 | 0 | 3044949 | 102911 | None | code81 | Providing 12 mm cement plaster with Cement mortar 1:4 (1cement: 4 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. (Vol -II- Page No-42, It No.8.4.2. Second floor | Sqm | 356.43 | 356.43 | 30.0 | False | None | None | False | None | False | 10692.9 | 0 | 3044950 | 102911 | None | code82 | Providing 12 mm cement plaster with Cement mortar 1:4 (1cement: 4 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete. (Vol -II- Page No-42, It No.8.4.2. Third floor | Sqm | 359.92 | 359.92 | 48.0 | False | None | None | False | None | False | 17276.16 | 0 | 3044951 | 102911 | None | code83 | CINDER CONCRETE FOR SUNKEN FILLING: Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. (Vol -II- Page No-23, It No7.18) Toilet | Cum | 2315.52 | 2315.52 | 22.5 | False | None | None | False | None | False | 52099.2 | 0 | 3044952 | 102911 | None | code84 | PLUMBING: SANITARY FIXTURES; Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid.( Vol -II- Page No- 131, It No.14.3.1) | Each | 6694.24 | 6694.24 | 6.0 | False | None | None | False | None | False | 40165.44 | 0 | 3044953 | 102911 | None | code85 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 g., Make: G0204A1, Supplying & Installation, ( Vol -II- Page No- 119, It No.13.13) | Nos | 947.52 | 947.52 | 16.0 | False | None | None | False | None | False | 15160.32 | 0 | 3044954 | 102911 | None | code86 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required-White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests, ( Vol -II- Page No- 131, It No.14.1.1) | Each | 5470.08 | 5470.08 | 10.0 | False | None | None | False | None | False | 54700.8 | 0 | 3044955 | 102911 | None | code87 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. ( Vol -II- Page No- 136, It No.14.31) | Each | 1366.4 | 1366.4 | 10.0 | False | None | None | False | None | False | 13664.0 | 0 | 3044956 | 102911 | None | code88 | Providing and fixing C.P. brass 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.( Vol -II- Page No- 137, It No.14.40.2) | Each | 555.52 | 555.52 | 14.0 | False | None | None | False | None | False | 7777.28 | 0 | 3044957 | 102911 | None | code89 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.. ( Vol -II- Page No- 119, It No.13.15) | Each | 812.0 | 812.0 | 14.0 | False | None | None | False | None | False | 11368.0 | 0 | 3044958 | 102911 | None | code90 | Providing and fixing in position chromium plated brass shower rose with 15 or 20mm inlet 150mm dia including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.16 / 13.3. ( Vol -II- Page No- 118, It No.13.9.1) | Nos | 287.84 | 287.84 | 14.0 | False | None | None | False | None | False | 4029.76 | 0 | 3044959 | 102911 | None | code91 | INTERNAL & EXTERNAL SEWAGE SYSTEM : Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 160mm dia., 6 kg/sqcm & class 3, 160mm PVC PIPE, ( Vol -V- Page No- 113, It No.10.1.9) | m | 692.16 | 692.16 | 30.0 | False | None | None | False | None | False | 20764.8 | 0 | 3044960 | 102911 | None | code92 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 110mm dia., 6 kg/sqcm & class 3, 110mm PVC PIPE., ( Vol -V- Page No- 113, It No.10.1.7) | m | 460.32 | 460.32 | 50.0 | False | None | None | False | None | False | 23016.0 | 0 | 3044961 | 102911 | None | code93 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:-PVC pipes 90mm dia., 6 kg/sqcm & class 3, ( Vol -V- Page No- 113, It No.10.1.6) | m | 329.28 | 329.28 | 70.0 | False | None | None | False | None | False | 23049.6 | 0 | 3044962 | 102911 | None | code94 | PVC pipes 50mm dia., 6 kg/sqcm & class 5, ( Vol -V- Page No- 113, It No.10.1.3) | m | 113.12 | 113.12 | 20.0 | False | None | None | False | None | False | 2262.4 | 0 | 3044963 | 102911 | None | code95 | PVC pipes 32mm dia., 10 kg/sqcm & class 5 ( Vol -V- Page No- 113, It No.10.1.2) | m | 75.04 | 75.04 | 20.0 | False | None | None | False | None | False | 1500.8 | 0 | 3044964 | 102911 | None | code96 | c) PVC pipes 200mm dia., 6 kg/sqcm & class 3 -For external ( Vol -V- Page No- 113, It No.10.1.10) | m | 1248.8 | 1248.8 | 50.0 | False | None | None | False | None | False | 62440.0 | 0 | 3044965 | 102911 | None | code97 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 50mm dia PVC couplers, ( Vol -V- Page No- 116, It No.10.8.4) | Each | 31.36 | 31.36 | 13.0 | False | None | None | False | None | False | 407.68 | 0 | 3044966 | 102911 | None | code98 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 90mm dia PVC couplers, ( Vol -V- Page No- 116, It No.10.8.7) | Each | 140.0 | 140.0 | 10.0 | False | None | None | False | None | False | 1400.0 | 0 | 3044967 | 102911 | None | code99 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 110mm dia PVC couplers, ( Vol -V- Page No- 116, It No.10.8.8) | Each | 191.52 | 191.52 | 2.0 | False | None | None | False | None | False | 383.04 | 0 | 3044968 | 102911 | None | code100 | Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments 160mm dia PVC couplers, ( Vol -V- Page No- 116, It No.10.8.10) | Each | 375.2 | 375.2 | 2.0 | False | None | None | False | None | False | 750.4 | 0 | 3044969 | 102911 | None | code101 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 50mm dia PVC Elbows ( Vol -V- Page No- 117, It No.10.9.4) | Each | 73.92 | 73.92 | 13.0 | False | None | None | False | None | False | 960.96 | 0 | 3044970 | 102911 | None | code102 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 90mm dia PVC Elbows ( Vol -V- Page No- 117, It No.10.9.7) | Each | 309.12 | 309.12 | 8.0 | False | None | None | False | None | False | 2472.96 | 0 | 3044971 | 102911 | None | code103 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 110mm dia PVC Elbows ( Vol -V- Page No- 117, It No.10.9.8) | Each | 338.24 | 338.24 | 3.0 | False | None | None | False | None | False | 1014.72 | 0 | 3044972 | 102911 | None | code104 | Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 160mm dia PVC Elbows ( Vol -V- Page No- 117, It No.10.9.10) | Each | 527.52 | 527.52 | 2.0 | False | None | None | False | None | False | 1055.04 | 0 | 3044973 | 102911 | None | code105 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 50mm dia PVC Tee, ( Vol -V- Page No- 118, It No.10.10.4) | Each | 68.32 | 68.32 | 7.0 | False | None | None | False | None | False | 478.24 | 0 | 3044974 | 102911 | None | code106 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 90mm dia PVC Tee, ( Vol -V- Page No- 119, It No.10.10.7) | Each | 191.52 | 191.52 | 7.0 | False | None | None | False | None | False | 1340.64 | 0 | 3044975 | 102911 | None | code107 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 110mm dia PVC Tee, ( Vol -V- Page No- 120, It No.10.10.8) | Each | 281.12 | 281.12 | 1.0 | False | None | None | False | None | False | 281.12 | 0 | 3044976 | 102911 | None | code108 | Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments, 160mm dia PVC Tee, ( Vol -V- Page No- 121, It No.10.10.10) | Each | 521.92 | 521.92 | 1.0 | False | None | None | False | None | False | 521.92 | 0 | 3044977 | 102911 | None | code109 | WATER SUPPLY SYSTEM: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall, a) 20 mm dia, ( Vol -II- Page No- 122, It No.13.31.2) | m | 271.04 | 271.04 | 45.0 | False | None | None | False | None | False | 12196.8 | 0 | 3044978 | 102911 | None | code110 | WATER SUPPLY SYSTEM: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall, b) 25 mm dia, ( Vol -II- Page No- 122, It No.13.31.3) | m | 356.16 | 356.16 | 30.0 | False | None | None | False | None | False | 10684.8 | 0 | 3044979 | 102911 | None | code111 | WATER SUPPLY SYSTEM: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall, c) 32 mm dia, ( Vol -II- Page No- 122, It No.13.31.4) | m | 448.0 | 448.0 | 20.0 | False | None | None | False | None | False | 8960.0 | 0 | 3044980 | 102911 | None | code112 | WATER SUPPLY SYSTEM: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall, d) 50 mm dia, ( Vol -II- Page No- 122, It No.13.31.6) | m | 874.72 | 874.72 | 20.0 | False | None | None | False | None | False | 17494.4 | 0 | 3044981 | 102911 | None | code113 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end), ( Vol -II- Page No- 117, It No.13.4.1) c) 25mm dia (Screwed ends) | Nos | 614.88 | 614.88 | 5.0 | False | None | None | False | None | False | 3074.4 | 0 | 3044982 | 102911 | None | code114 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end), ( Vol -II- Page No- 117, It No.13.4.2) d) 32mm dia (Screwed ends) | Nos | 669.76 | 669.76 | 2.0 | False | None | None | False | None | False | 1339.52 | 0 | 3044983 | 102911 | None | code115 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end), ( Vol -II- Page No- 117, It No.13.4.3) e) 40mm dia (Screwed ends) | Nos | 786.24 | 786.24 | 2.0 | False | None | None | False | None | False | 1572.48 | 0 | 3044984 | 102911 | None | code116 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end), ( Vol -II- Page No- 117, It No.13.4.4) f) 40mm dia (Screwed ends) | Nos | 957.6 | 957.6 | 1.0 | False | None | None | False | None | False | 957.6 | 0 | 3044985 | 102911 | None | code117 | Solar hot water heater: Supplying, installation, testing and commissioning of solar hot water heater comprising of high quality Evacuated Glass Tube (EGT) with absorber coating collector of size 58 x 1800 mm. Inner tank Material-Stainless steel 304-L Grade with Aluminium Stucco cladding made of High quality PUF insulation to minimizes heat loss and hold water Temperature upto 72 Hrs...with appropriate capacityelectrical back up arrangement excluding inlet and out let pipes. Fitted withSacrificial Anode ( Vol -VI- Page No- 35, It No.7.4.3)7.4.3)300 L- 29 nos Tubes | Each | 51528.0 | 51528.0 | 4.0 | False | None | None | False | None | False | 206112.0 | 0 | 3044986 | 102911 | None | code118 | INTERNAL ELECTRICAL: Point wiring using Copper wire without Switch. Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.GROUP A, 2.2.1)Short point upto 3Mtr from tapping point to out let via switch box (Vol- VI- Page No-5, It No.2.2) | Nos | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 | 3044987 | 102911 | None | code119 | Point wiring using Copper wire without Switch. Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.GROUP A, 2.2.2)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (Vol- VI- Page No-5, It No.2.2) | Nos | 379.0 | 379.0 | 10.0 | False | None | None | False | None | False | 3790.0 | 0 | 3044988 | 102911 | None | code120 | Point wiring using Copper wire without Switch. Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.GROUP A, 2.2.3)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (Vol- VI- Page No-5, It No.2.2) | Nos | 555.0 | 555.0 | 18.0 | False | None | None | False | None | False | 9990.0 | 0 | 3044989 | 102911 | None | code121 | Point wiring using Copper wire without Switch. Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.GROUP A, 2.2.4)Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switches (Vol- VI- Page No-5, It No.2.2) | Nos | 677.0 | 677.0 | 12.0 | False | None | None | False | None | False | 8124.0 | 0 | 3044990 | 102911 | None | code122 | Point wiring using Copper wire without Switch. Supplying and wiring adopting loop system in existing pvc conduit/casing caping using 1100v grade,COPPER conducter flexible multistrand FRLS PVC insulated,2x1.5Sq.mm Cable confirming to the GTP without switch,the other end of the wire shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.GROUP A,2.2.5)Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches box (Vol- VI- Page No-5, It No.2.2) | Nos | 989.0 | 989.0 | 9.0 | False | None | None | False | None | False | 8901.0 | 0 | 3044991 | 102911 | None | code123 | METAL BOX: Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (Vol- VI- Page No-8, It No.3.4), 3.4.1) 1-3Way | Each | 138.0 | 138.0 | 55.0 | False | None | None | False | None | False | 7590.0 | 0 | 3044992 | 102911 | None | code124 | METAL BOX: Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (Vol- VI- Page No-8, It No.3.4) ,3.4.2)4-5Way | Each | 177.0 | 177.0 | 15.0 | False | None | None | False | None | False | 2655.0 | 0 | 3044993 | 102911 | None | code125 | METAL BOX: Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (Vol- VI- Page No-8, It No.3.4) 3.4.3)6 Way | Each | 220.0 | 220.0 | 8.0 | False | None | None | False | None | False | 1760.0 | 0 | 3044994 | 102911 | None | code126 | METAL BOX: Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (Vol- VI- Page No-8, It No.3.4) 3.4.4)8Way | Each | 261.0 | 261.0 | 22.0 | False | None | None | False | None | False | 5742.0 | 0 | 3044995 | 102911 | None | code127 | METAL BOX: Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates.The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (Vol- VI- Page No-8, It No.3.4) 3.4.5) 10-12Way | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 | 3044996 | 102911 | None | code128 | Deep juction box: Suppling and fixing PV, C/metal conduit deep juction boxes, 1.5.1)19/20mm deep juction box, (Vol- VI- Page No-3, It No.1.5) | Each | 49.0 | 49.0 | 56.0 | False | None | None | False | None | False | 2744.0 | 0 | 3044997 | 102911 | None | code129 | Deep juction box: Suppling and fixing PV, C/metal conduit deep juction boxes, 1.5.2) 25mm deep juction box (Vol- VI- Page No-3, It No.1.5) | Each | 56.0 | 56.0 | 45.0 | False | None | None | False | None | False | 2520.0 | 0 | 3044998 | 102911 | None | code130 | Deep juction box: Suppling and fixing PV, C/metal conduit deep juction boxes, 1.5.3) 32mm deep juction box (Vol- VI- Page No-3, It No.1.5) | Each | 61.0 | 61.0 | 10.0 | False | None | None | False | None | False | 610.0 | 0 | 3044999 | 102911 | None | code131 | Deep juction box: Suppling and fixing PV, C/metal conduit deep juction boxes, 1.13)Suplay and fixing Metal Fan Box with Round Hook (Vol- VI- Page No-3, It No.1.5) | Each | 117.0 | 117.0 | 24.0 | False | None | None | False | None | False | 2808.0 | 0 | 3045000 | 102911 | None | code132 | Supplying and mounting 2 nos of 2 way 6amps flush type switches either surface /flush mounted on exisinting gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required , (Vol- VI- Page No-8, It No.3.2) | Each | 170.0 | 170.0 | 3.0 | False | None | None | False | None | False | 510.0 | 0 | 3045001 | 102911 | None | code133 | Switch mounting polycorbonate plate: Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (Vol- VI- Page No-8, It No.3.5), 'A' Group, 3.5.1) 1 to 2Module | Each | 137.0 | 137.0 | 55.0 | False | None | None | False | None | False | 7535.0 | 0 | 3045002 | 102911 | None | code134 | Switch mounting polycorbonate plate: Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (Vol- VI- Page No-8, It No.3.5), 'A' Group, 3.5.2) 4 Module | Each | 175.0 | 175.0 | 15.0 | False | None | None | False | None | False | 2625.0 | 0 | 3045003 | 102911 | None | code135 | Switch mounting polycorbonate plate: Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (Vol- VI- Page No-8, It No.3.5), 'A' Group, 3.5.3) 6 Module | Each | 234.0 | 234.0 | 8.0 | False | None | None | False | None | False | 1872.0 | 0 | 3045004 | 102911 | None | code136 | Switch mounting polycorbonate plate: Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (Vol- VI- Page No-8, It No.3.5), 'A' Group,3.5.4) 8 Module | Each | 284.0 | 284.0 | 22.0 | False | None | None | False | None | False | 6248.0 | 0 | 3045005 | 102911 | None | code137 | Switch mounting polycorbonate plate: Supplying and fixing superior gality modular switch mounting polycorbonate plate with neceaary supporting back plate with rquired nos. of machine screwes, bolts nuts etc., complete on the existing metal/PVC box. (Vol- VI- Page No-8, It No.3.5), 'A' Group,3.5.5) 10-12 Module | Each | 344.0 | 344.0 | 5.0 | False | None | None | False | None | False | 1720.0 | 0 | 3045006 | 102911 | None | code138 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.1) 6A mps one way | Each | 102.0 | 102.0 | 155.0 | False | None | None | False | None | False | 15810.0 | 0 | 3045007 | 102911 | None | code139 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.2) 6A mps Two way | Each | 166.0 | 166.0 | 6.0 | False | None | None | False | None | False | 996.0 | 0 | 3045008 | 102911 | None | code140 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.3) 6A mps 3way socket. | Each | 171.0 | 171.0 | 55.0 | False | None | None | False | None | False | 9405.0 | 0 | 3045009 | 102911 | None | code141 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.4) Stepped fan regulator. | Each | 357.0 | 357.0 | 24.0 | False | None | None | False | None | False | 8568.0 | 0 | 3045010 | 102911 | None | code142 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.7) 16Amps one way switch | Each | 180.0 | 180.0 | 8.0 | False | None | None | False | None | False | 1440.0 | 0 | 3045011 | 102911 | None | code143 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.10) 6/16Amps univeral socket | Each | 236.0 | 236.0 | 8.0 | False | None | None | False | None | False | 1888.0 | 0 | 3045012 | 102911 | None | code144 | Modular switch/Socket: Supplying and fixing of modular switch/Socket/stepped electeonic fan regulator/ dimmer/telephone socket etc on existing modular switch plate. (Vol- VI- Page No-9, It No.3.6)Using Group 'A' materials, 3.6.11) TV/Telephone socket | Each | 156.0 | 156.0 | 4.0 | False | None | None | False | None | False | 624.0 | 0 | 3045013 | 102911 | None | code145 | Supplyingandfixing32AsecurityandenergysavingDPswitchwithkeytagsuitabletooperateon230V,50HzACsupply&completely wired on existing box. (Vol- VI- Page No-5, It No.3.7) | Each | 646.0 | 646.0 | 8.0 | False | None | None | False | None | False | 5168.0 | 0 | 3045014 | 102911 | None | code146 | Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary, (Vol- VI- Page No-2, It No.1.2) 1.2.1) 19/20mm dia 2mm thik | m | 66.0 | 66.0 | 1500.0 | False | None | None | False | None | False | 99000.0 | 0 | 3045015 | 102911 | None | code147 | Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary, (Vol- VI- Page No-2, It No.1.2) 1.2.2) 25mm dia 2mm thik | m | 78.0 | 78.0 | 1600.0 | False | None | None | False | None | False | 124800.0 | 0 | 3045016 | 102911 | None | code148 | Concealed Conduit System: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… and running before concreting th eslab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be convered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary, (Vol- VI- Page No-2, It No.1.2) 1.2.3) 32mm dia 2.5mm thik | m | 103.0 | 103.0 | 80.0 | False | None | None | False | None | False | 8240.0 | 0 | 3045017 | 102911 | None | code149 | Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Vol- VI- Page No-2, It No.1.3) , 1.3.1) 19/20mm dia 2mm thik | m | 68.0 | 68.0 | 250.0 | False | None | None | False | None | False | 17000.0 | 0 | 3045018 | 102911 | None | code150 | Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Vol- VI- Page No-2, It No.1.3) ,1.3.2) 25mm dia 2mm thik | m | 79.0 | 79.0 | 200.0 | False | None | None | False | None | False | 15800.0 | 0 | 3045019 | 102911 | None | code151 | Groove cutting: Supplying …. Mm dia 2mm2.5mm Thick heavy gauge PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive paste etc… by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. (Vol- VI- Page No-2, It No.1.3) 1.3.3) 32mm dia 2.5mm thik | m | 99.0 | 99.0 | 50.0 | False | None | None | False | None | False | 4950.0 | 0 | 3045020 | 102911 | None | code152 | Wiring for lighting /power circuit : wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010, I Group A Materials. 2.3.2) 1.5 sqmm, (Vol- VI- Page No-5, It No.2.3) | m | 26.0 | 26.0 | 1100.0 | False | None | None | False | None | False | 28600.0 | 0 | 3045021 | 102911 | None | code153 | Wiring for lighting /power circuit : wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010, I Group A Materials. 2.3.3) 2.5 sqmm, (Vol- VI- Page No-5, It No.2.3) | m | 42.0 | 42.0 | 950.0 | False | None | None | False | None | False | 39900.0 | 0 | 3045022 | 102911 | None | code154 | Wiring for lighting /power circuit : wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010, I Group A Materials. 2.3.4) 4 sqmm, (Vol- VI- Page No-5, It No.2.3) | m | 63.0 | 63.0 | 350.0 | False | None | None | False | None | False | 22050.0 | 0 | 3045023 | 102911 | None | code155 | Wiring for lighting /power circuit : wiring for lighting/powe rcircuitusing one of FRLS PVC insulated1100Vgrade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring withspecifiedIS-694:2010, I Group A Materials. 2.3.3) 6 sqmm, (Vol- VI- Page No-5, It No.2.3) | m | 92.0 | 92.0 | 350.0 | False | None | None | False | None | False | 32200.0 | 0 | 3045024 | 102911 | None | code156 | Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete, II. Double Door, 8Way SP & N , 1) Group 'A' , (Vol- VI- Page No-18, It No.5.19.8) | Each | 1854.0 | 1854.0 | 1.0 | False | None | None | False | None | False | 1854.0 | 0 | 3045025 | 102911 | None | code157 | Supplying and fixing regular MCB distribution boards on wall/ woodboard /flush mounting required clamps,bolts,nuts etc.. with provision for fixing suitable type capacity MCB's single phase /3 phase /single door with powder coated painting etc., complete, III. Double Door, 6Way TP & N , 1) Group 'A' , (Vol- VI- Page No-18, It No.5.19.12) | Each | 4940.0 | 4940.0 | 1.0 | False | None | None | False | None | False | 4940.0 | 0 | 3045026 | 102911 | None | code158 | Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board., 5.20.4)32-40 Amps 2 Pole, (Vol- VI- Page No-18, It No.5.20) | Each | 4559.0 | 4559.0 | 1.0 | False | None | None | False | None | False | 4559.0 | 0 | 3045027 | 102911 | None | code159 | Supplying and fixing and wiring Earth Leakage Miniature Circuit Breaker [RCCB] 240/450V up 300mA sensitivity on exsiting wood/panel board., 5.20.8)32-40 Amps 4 Pole (Vol- VI- Page No-18, It No.5.20) | Each | 5147.0 | 5147.0 | 1.0 | False | None | None | False | None | False | 5147.0 | 0 | 3045028 | 102911 | None | code160 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C'Type curve,indicatorON/OFF,energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 5.18.1)6-32Amps SP, 1 Group 'A' (Vol- VI- Page No-11, It No.5.18) | Each | 415.0 | 415.0 | 15.0 | False | None | None | False | None | False | 6225.0 | 0 | 3045029 | 102911 | None | code161 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C'Type curve,indicatorON/OFF,energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC60898. 5.18.9)50-63Amps TPN 1 Group 'A' (Vol- VI- Page No-11, It No.5.18) | Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 | 3045030 | 102911 | None | code162 | PART -B-1 LIGHT FIXTURES : Supplying & fixing cast Aluminium round or oblong type bulk head fitting with GI wire guard,glass cover with 15 watts 230V CFL lamp, (Vol- VI- Page No-44, It No.13) | Each | 68.0 | 68.0 | 4.0 | False | None | None | False | None | False | 272.0 | 0 | 3045031 | 102911 | None | code163 | Supplying of 2 feet LED PVC square batten with high quality diffuser with ife of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 5 years warranty, 11.3.1)LED light fitting 1x2' -9/10w, (Vol- VI- Page No-43, It No.11.3) | Each | 551.0 | 551.0 | 2.0 | False | None | None | False | None | False | 1102.0 | 0 | 3045032 | 102911 | None | code164 | Supplying of 2 feet LED PVC square batten with high quality diffuser with ife of 25000 burninng hours & 70% lumen maintance with CRI 80. power input :220-240V @ 50 hz & power factor .9 along with CE approved drivers. 5 years warranty, 11.3.2)LED light fitting 1x4' -20/22w (Vol- VI- Page No-43, It No.11.3) | Each | 690.0 | 690.0 | 45.0 | False | None | None | False | None | False | 31050.0 | 0 | 3045033 | 102911 | None | code165 | Supplying of recess/Surface mounting non integrated type LED down light ...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 11.5.2) 10-12W, (Vol- VI- Page No-44, It No.11.5) | Each | 885.0 | 885.0 | 12.0 | False | None | None | False | None | False | 10620.0 | 0 | 3045034 | 102911 | None | code166 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, deliveringsuperior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency 1301m/w, nominal CRI 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned LED Streetlight 90 W, (Vol- VI- Page No-46, It No.11.8.4) | Nos | 8860.0 | 8860.0 | 4.0 | False | None | None | False | None | False | 35440.0 | 0 | 3045035 | 102911 | None | code167 | Supplying exhaust fan of 1440 RPM of 300 mm (12'') size with bracket blades complete for light duty suitable for operate of 230V 50Hz, AC Supply..a) Group 'A', (Vol- VI- Page No-30, It No.6.1) | Each | 1492.0 | 1492.0 | 4.0 | False | None | None | False | None | False | 5968.0 | 0 | 3045036 | 102911 | None | code168 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double bail bearing system. (Vol- VI- Page No-22, It No.6.3.1) 48" Sweep (1200mm), 6.3.1)Regular model (Khaitan, Crompton Greaves, Orient, Polar, Bajaj, Usha, Havells, Almonard) | Each | 2984.0 | 2984.0 | 24.0 | False | None | None | False | None | False | 71616.0 | 0 | 3045037 | 102911 | None | code169 | Labour Portion; Fixing all types and all capacities of fluorescent / fales ceiling /spot light /CFL / LED fittings indoor on the wall /ceiling / refters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps .On wall / ceiling / Rafter / Girders, (Vol- VI- Page No-56, It No.11.37.1) | Each | 122.0 | 122.0 | 67.0 | False | None | None | False | None | False | 8174.0 | 0 | 3045038 | 102911 | None | code170 | Fixing a ceiling / wall mounting fan of all capacities and all types to the existing 's' hook with fan regulator to the existing board together with supplying and fixiting 5amps . Ceiling rose, necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring .(Vol- VI- Page No-57, It No.13.10) | Each | 171.0 | 171.0 | 28.0 | False | None | None | False | None | False | 4788.0 | 0 | 3045039 | 102911 | None | code171 | PART - DPART - C Networking (CCTV) & Telecommunication Works: Supplying and drawing UTP-CAT 6E LAN Cable, a)Group A, .(Vol- VI- Page No-36, It No.8.1) | m | 38.0 | 38.0 | 150.0 | False | None | None | False | None | False | 5700.0 | 0 | 3045040 | 102911 | None | code172 | Supplying and drawing PVC flexible one pair telephone unarmoured tinner copper cable of approval make. 8.2.2)2 Pair (Vol- VI- Page No-36, It No.8.2) | m | 21.0 | 21.0 | 60.0 | False | None | None | False | None | False | 1260.0 | 0 | 3045041 | 102911 | None | code173 | supplying fixing of I/O socket with back box, 8.10.1)Single I/o, (Vol- VI- Page No-36, It No.8.10) | Each | 490.0 | 490.0 | 6.0 | False | None | None | False | None | False | 2940.0 | 0 | 3045042 | 102911 | None | code174 | supplying fixing of … mtrs Cat6 patch cable, 8.11.1)1mtr, (Vol- VI- Page No-37, It No.8.11) | Each | 224.0 | 224.0 | 6.0 | False | None | None | False | None | False | 1344.0 | 0 | 3045043 | 102911 | None | code175 | supplying fixing of PVC inssulated gas injected physical foam jelly flooded co-axial TV RG-6 cable, (Vol- VI- Page No-36, It No.8.3) | m | 44.0 | 44.0 | 40.0 | False | None | None | False | None | False | 1760.0 | 0 | 3045044 | 102911 | None | code176 | CULVERT: Earth work excavation for pipeline trenches in all kinds of by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & bonding rods at every 100 mm whevere necessary as directed, removal of slumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work and all other appurtenances to complete in the following strata. (Vol- I- Page No-10, It No.1.17.1)6 m Culvert , Considering 100% of the qnty for ordinary soil | Cum | 293.44 | 293.44 | 14.83 | False | None | None | False | None | False | 4351.7152 | 0 | 3045045 | 102911 | None | code177 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap /basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse
aggregates (Vol- I- Page No-15, It No.2.1.3))6 m Culvert | Cum | 6707.68 | 6707.68 | 1.06 | False | None | None | False | None | False | 7110.1408 | 0 | 3045046 | 102911 | None | code178 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (Vol- I- Page No-75, It No.2.4.2))6 m Culvert, consider 10% of finished rate of concrete for Earth retaining structures shuttering | Cum | 7789.94 | 7789.94 | 4.74 | False | None | None | False | None | False | 36924.3156 | 0 | 3045047 | 102911 | None | code179 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol-I-Pgno-18-2.11(a) | Kg | 100191.84 | 100191.84 | 0.7 | False | None | None | False | None | False | 70134.288 | 0 | 3045048 | 102911 | None | code180 | Compound wall-Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m, )(Vol- I- Page No-8, It No.1.14.1) | Cum | 114.24 | 114.24 | 41.04 | False | None | None | False | None | False | 4688.4096 | 0 | 3045049 | 102911 | None | code181 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Vol- I- Page No-7, It No.1.9) | Cum | 297.92 | 297.92 | 25.95 | False | None | None | False | None | False | 7731.024 | 0 | 3045050 | 102911 | None | code182 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate ibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates. (Vol- I- Page No-15, It No.2.1.3) | Cum | 6707.68 | 6707.68 | 7.99 | False | None | None | False | None | False | 53594.3632 | 0 | 3045051 | 102911 | None | code183 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Vol- I- Page No-15, It No.2.1.3) | Cum | 7664.03 | 7664.03 | 10.37 | False | None | None | False | None | False | 79475.9911 | 0 | 3045052 | 102911 | None | code184 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates, (Vol- I- Page No-16, It No.2.5.2) | Cum | 13029.07 | 13029.07 | 2.59 | False | None | None | False | None | False | 33745.2913 | 0 | 3045053 | 102911 | None | code185 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Vol-I-Pgno-18-2.11(a) | Tonne | 100191.84 | 100191.84 | 1.01 | False | None | None | False | None | False | 101193.7584 | 0 | 3045054 | 102911 | None | code186 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(Vol- II- Page No-9, It No.5.4) | Cum | 7155.68 | 7155.68 | 17.76 | False | None | None | False | None | False | 127084.8768 | 0 | 3045055 | 102911 | None | code187 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(Vol- II- Page No-17, It No.6.33) | Sqm | 1378.72 | 1378.72 | 88.8 | False | None | None | False | None | False | 122430.336 | 0 | 3045056 | 102911 | None | code188 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External. (Vol- II- Page No-42, It No.8.8) | Sqm | 415.52 | 415.52 | 201.28 | False | None | None | False | None | False | 83635.8656 | 0 | 3045057 | 102911 | None | code189 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. . (Vol- II- Page No-46, It No.8.31) | Sqm | 199.36 | 199.36 | 201.28 | False | None | None | False | None | False | 40127.1808 | 0 | 3045058 | 102911 | None | code190 | Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Vol- II- Page No-75, It No.11.4) | Sqm | 5847.52 | 5847.52 | 12.6 | False | None | None | False | None | False | 73678.752 | 0 | 3045059 | 102911 | None | code191 | DIESEL GENERATOR SET-'Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications.Use of special hardware for longer life, Insulation materialmeets exacting IS 8183 specifications for better sound attenuation, Flush styling - no projections, Fluid drains for lube oil and fuel, Fuel filling point inside the enclosure. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and
Rules.30 kVA/24kW-Vol-VI-pgno-42-10.1.4 | Set | 457067.0 | 457067.0 | 1.0 | False | None | None | False | None | False | 457067.0 | 0 | 3045060 | 102911 | None | code192 | Supply, Erection, testing and commissioning of AMF panel
suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage,
....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules.30 kVA/24kW-Vol-VI-pgno-42-10.2.1 | Each | 58711.0 | 58711.0 | 1.0 | False | None | None | False | None | False | 58711.0 | 0 | 3045061 | 102911 | None | code193 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (vol-II-pg no-17-Item no-6.32) -dg-platform | Sqm | 1310.0 | 1310.0 | 8.1 | False | None | None | False | None | False | 10611.0 | 0 | 3045062 | 102911 | None | code194 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.(vol-II-pg no-23-Item no-7.18) | Sqm | 2017.0 | 2017.0 | 9.0 | False | None | None | False | None | False | 18153.0 | 0 | 3045063 | 102911 | None | code195 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.External (vol-II-pg no-42-Item no-8.8) | Sqm | 371.0 | 371.0 | 28.1 | False | None | None | False | None | False | 10425.1 | 0 | 3045064 | 102911 | None | code196 | Providing throating elevation Patti on uniform size 10 cm wide and 12 mm thick for portico, chejjas & parapet wall elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.all-round | m | 61.86 | 61.86 | 120.0 | False | None | None | False | None | False | 7423.2 | 0 | 3045065 | 102911 | None | code197 | Forming horizontal or vertical grooves on uniform size 10 mm wide and 7 mm deep at junction of wall and column / beam and finishing the grooves to elevation etc, including cost of materials , labour floor fixing, HOM of equipments and machineries all leads and lift loading and unloading, transportation , all other incidental charges at all floor levels etc, complete all as per specifications and as directed by the Engineer in charge.all-round outer wall horizontal | m | 26.27 | 26.27 | 280.0 | False | None | None | False | None | False | 7355.6 | 0 | 3045066 | 102911 | None | code198 | Providing and fixing Aluminium fixtures like Aldrops of size 300 x 16 mm, Tower bolts of size 200 x 12 mm, Latches of size 250 x12 mm, 100 mm length oxidized Iron Hinges, Handles of size 150 mm, Door Stopper & Door Bush of approved make and quality including cost and conveyance of all materials and as per the direction of EIC of work with all lead and lift and as directed by the Engineer in charge of works. Single Shutter. | Nos | 3951.69 | 3951.69 | 9.0 | False | None | None | False | None | False | 35565.21 | 0 | 3045067 | 102911 | None | code199 | Supplying, installing and testing 2WAY BIB COCK (Ritco flora or equivalent) & 15 mm CP health faucet (Hindware F160027 or equivalent) of approved make with necessary CP flexible hose 1200mm long nozzle, CP wall flange etc., including cost of materials,labour complte as per specification complete. | Nos | 1307.63 | 1307.63 | 14.0 | False | None | None | False | None | False | 18306.82 | 0 | 3045068 | 102911 | None | code200 | Supplying, fixing, testing and commissioning of two - in - one wall mixer shower assembly unit consisting of the following in the shower area: Standard make confirming to ISI standards,Model as per attached photo catalogue and as per instruction of engineer incharge. Single Lever Wall Mixer with provision of Hand Shower, but without Hand Shower SKU: ARI-CHR-39119 (jaquar or equilent Make) | Nos | 6947.46 | 6947.46 | 4.0 | False | None | None | False | None | False | 27789.84 | 0 | 3045069 | 102911 | None | code201 | CAMERAS & ACCESSORIES: Supply, erection, testing & commissioning 2 Megapixel high-performance CMOS, Analog HD output, up to 1080P resolution, True Day/Night, True WDR, up to 120dB,EXIR technology, up to 20m IR distance , IP66 weatherproof ,Max. 5W, with 4*4 Model Box for Camera and other accessories. | Nos | 4676.27 | 4676.27 | 6.0 | False | None | None | False | None | False | 28057.62 | 0 | 3045070 | 102911 | None | code202 | Supply, erection, testing & commissioning of 12/24V, 4 out put Camera Power Supply (SMPS, switched-mode power supply) Each Camera have Separate Terminal, including all Accessories. | Nos | 1298.31 | 1298.31 | 6.0 | False | None | None | False | None | False | 7789.86 | 0 | 3045071 | 102911 | None | code203 | Providing and fixing in position brass push cock of approved quality 15mm nominal bore including cost of all materials, CP wall flange etc., including cost of materials,labour complte as per specification complete.Supplying & Installation | Nos | 720.34 | 720.34 | 16.0 | False | None | None | False | None | False | 11525.44 | 0 | 3045072 | 102911 | None | code204 | Providing and fixing in position precast ferrocement slab of 20mm thick and 600mm wide for storage rack suitable for storage of office files with required length including finishing, painting , labour charges, transportation, materials charges any taxes applicable etc,. complete as directed by the Engineer incharge of the work.concrete mix proportion: Equivalent to M25 Strength, mild steel flats of size 20x3 mm diameter are to be used for main and distribution reinforcement.Chicken mesh is to be provided in two layer for secondary reinforcement. | Sqm | 2796.61 | 2796.61 | 138.0 | False | None | None | False | None | False | 385932.18 | 0 |
|